1
|
Pan J, Sun W, Li X, Hao Y, Bai Y, Nan D. A noval transparent triboelectric nanogenerator as electronic skin for real-time breath monitoring. J Colloid Interface Sci 2024; 671:336-343. [PMID: 38815370 DOI: 10.1016/j.jcis.2024.05.127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 05/13/2024] [Accepted: 05/16/2024] [Indexed: 06/01/2024]
Abstract
Against the backdrop of advancements in modern multifunctional wearable electronics, there is a growing demand for simple, sustainable, and portable electronic skin (e-skin), posing significant challenges. This study aims to delineate the development of a straightforward, transparent, highly sensitive, and high power-density electronic skin based on a triboelectric nanogenerator(S-TENG), designed for harvesting human body energy and real-time monitoring of the physiological motion status. Our e-skin incorporates thermally treated polyvinylidene fluoride (PVDF) fiber membranes as the contact layer and a film of silver nanowires as the conductive electrodes. The resulting contact-separation type e-skin exhibits an impressive transparency of 80 %, along with a nice sensitivity value, capable of detecting a light touch from a 0.13 g sponge and demonstrating good working stability and breathability. Leveraging the triboelectric effect, our e-skin generates an open-circuit voltage of 301 V and a short-circuit current of 2.7 μA under an extrinsic force of 8 N over an interaction area of 4 × 4 cm2, achieving a power density up to 306 mW/m2. With its signal processing circuitry, the integrated S-TENG showcases nice energy harvesting and signal transmission capabilities. Accordingly, we contend that S-TENG has potential applications in energy capture and real-time human motion state monitoring. This research is anticipated to blaze a novel and practical trail for self-powered wearable devices and personalized health rehabilitation training regimens.
Collapse
Affiliation(s)
- Juan Pan
- College of Chemistry and Chemical Engineering of Inner Mongolia University, Hohhot 010021, PR China; Institute of Applied Nanotechnology, Jiaxing, Zhejiang 314031, PR China
| | - Wuliang Sun
- School of Materials Science and Engineering, Inner Mongolia University of Technology, Hohhot 010051, PR China; Institute of Applied Nanotechnology, Jiaxing, Zhejiang 314031, PR China
| | - Xin Li
- College of Chemistry and Chemical Engineering of Inner Mongolia University, Hohhot 010021, PR China
| | - Yutao Hao
- Institute of Applied Nanotechnology, Jiaxing, Zhejiang 314031, PR China
| | - Yu Bai
- Shanghai XFH Science and Technology Development Co., Ltd., Building A7, No. 11, Lane 635, Xiaoyun Road, Baoshan District, Shanghai 200949, PR China; Shenzhen XFH Science and Technology Co., Ltd., Shenzhen 518071, PR China.
| | - Ding Nan
- College of Chemistry and Chemical Engineering of Inner Mongolia University, Hohhot 010021, PR China.
| |
Collapse
|
2
|
Cinquino M, Demir SM, Shumba AT, Schioppa EJ, Fachechi L, Rizzi F, Qualtieri A, Patrono L, Mastronardi VM, De Vittorio M. Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors. Biosens Bioelectron 2024; 267:116790. [PMID: 39332253 DOI: 10.1016/j.bios.2024.116790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 09/10/2024] [Accepted: 09/16/2024] [Indexed: 09/29/2024]
Abstract
Continuous monitoring of cardiovascular parameters like pulse wave velocity (PWV), blood pressure wave (BPW), stiffness index (SI), reflection index (RI), mean arterial pressure (MAP), and cardio-ankle vascular index (CAVI) has significant clinical importance for the early diagnosis of cardiovascular diseases (CVDs). Standard approaches, including echocardiography, impedance cardiography, or hemodynamic monitoring, are hindered by expensive and bulky apparatus and accessibility only in specialized facilities. Moreover, noninvasive techniques like sphygmomanometry, electrocardiography, and arterial tonometry often lack accuracy due to external electrical interferences, artifacts produced by unreliable electrode contacts, misreading from placement errors, or failure in detecting transient issues and trends. Here, we report a bio-compatible, flexible, noninvasive, low-cost piezoelectric sensor for continuous and real-time cardiovascular monitoring. The sensor, utilizing a thin aluminum nitride film on a flexible Kapton substrate, is used to extract heart rate, blood pressure waves, pulse wave velocities, and cardio-ankle vascular index from four arterial pulse sites: carotid, brachial, radial, and posterior tibial arteries. This simultaneous recording, for the first time in the same experiment, allows to provide a comprehensive cardiovascular patient's health profile. In a test with a 28-year-old male subject, the sensor yielded the SI = 7.1 ± 0.2 m/s, RI = 54.4 ± 0.5 %, MAP = 86.2 ± 1.5 mmHg, CAVI = 7.8 ± 0.2, and seven PWVs from the combination of the four different arterial positions, in good agreement with the typical values reported in the literature. These findings make the proposed technology a powerful tool to facilitate personalized medical diagnosis in preventing CVDs.
Collapse
Affiliation(s)
- Marco Cinquino
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy.
| | - Suleyman Mahircan Demir
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi, Torino, TO, 10129, Italy
| | - Angela Tafadzwa Shumba
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy
| | - Enrico Junior Schioppa
- Inmatica S.p.A., BE-Pilot Palace, Strada Comunale Tufi, Monteroni di Lecce, LE, 73047, Italy
| | - Luca Fachechi
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy
| | - Francesco Rizzi
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy
| | - Antonio Qualtieri
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy
| | - Luigi Patrono
- Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy
| | - Vincenzo Mariano Mastronardi
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy.
| | - Massimo De Vittorio
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy
| |
Collapse
|
3
|
Zhang X, Chen J, Zheng Z, Tang S, Cheng B, Zhang Z, Ma R, Chen Z, Zhuo J, Cao L, Chen Z, He J, Wang X, Yang G, Yi F. Flexible Temperature Sensor with High Reproducibility and Wireless Closed-Loop System for Decoupled Multimodal Health Monitoring and Personalized Thermoregulation. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2407859. [PMID: 39223852 DOI: 10.1002/adma.202407859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 08/08/2024] [Indexed: 09/04/2024]
Abstract
Temperature and pulse waves are two fundamental indicators of body health. Specifically, thermoresistive flexible temperature sensors are one of the most applied sensors. However, they suffer from poor reproducibility of resistivity; and decoupling temperature from pressure/strain is still challenging. Besides, autonomous thermoregulation by wearable sensory systems is in high demand, but conventional commercial apparatuses are cumbersome and not suitable for long-term portable use. Here, a material-design strategy is developed to overcome the problem of poor reproducibility of resistivity by tuning the thermal expansion coefficient to nearly zero, precluding the detriment caused by shape expansion/shrinkage with temperature variation and achieving high reproducibility. The strategy also obtains more reliable sensitivity and higher stability, and the designed thermoresistive fiber has strain-insensitive sensing performance and fast response/recovery time. A smart textile woven by the thermoresistive fiber can decouple temperature and pulse without crosstalk; and a flexible wireless closed-loop system comprising the smart textile, a heating textile, a flexible diminutive control patch, and a smartphone is designed and constructed to monitor health status in real-time and autonomously regulate body temperature. This work offers a new route to circumvent temperature-sensitive effects for flexible sensors and new insights for personalized thermoregulation.
Collapse
Affiliation(s)
- Xujing Zhang
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Jiaxiang Chen
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Zhihao Zheng
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, P. R. China
| | - Songsong Tang
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Bin Cheng
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Zhiwei Zhang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 101400, P. R. China
| | - Rui Ma
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Zetong Chen
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Jingting Zhuo
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Lingyun Cao
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Zhihong Chen
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Jiangfeng He
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Xiaofeng Wang
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, P. R. China
| | - Guowei Yang
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| | - Fang Yi
- School of Materials Science and Engineering, Nanotechnology Research Center, State Key Laboratory of Optoelectronic Materials and Technologies, Guangzhou Key Laboratory of Flexible Electronic Materials and Wearable Devices, Sun Yat-sen University, Guangzhou, 510275, P. R. China
| |
Collapse
|
4
|
Park JH, Pattipaka S, Hwang GT, Park M, Woo YM, Kim YB, Lee HE, Jeong CK, Zhang T, Min Y, Park KI, Lee KJ, Ryu J. Light-Material Interactions Using Laser and Flash Sources for Energy Conversion and Storage Applications. NANO-MICRO LETTERS 2024; 16:276. [PMID: 39186184 PMCID: PMC11347555 DOI: 10.1007/s40820-024-01483-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 07/13/2024] [Indexed: 08/27/2024]
Abstract
This review provides a comprehensive overview of the progress in light-material interactions (LMIs), focusing on lasers and flash lights for energy conversion and storage applications. We discuss intricate LMI parameters such as light sources, interaction time, and fluence to elucidate their importance in material processing. In addition, this study covers various light-induced photothermal and photochemical processes ranging from melting, crystallization, and ablation to doping and synthesis, which are essential for developing energy materials and devices. Finally, we present extensive energy conversion and storage applications demonstrated by LMI technologies, including energy harvesters, sensors, capacitors, and batteries. Despite the several challenges associated with LMIs, such as complex mechanisms, and high-degrees of freedom, we believe that substantial contributions and potential for the commercialization of future energy systems can be achieved by advancing optical technologies through comprehensive academic research and multidisciplinary collaborations.
Collapse
Affiliation(s)
- Jung Hwan Park
- Department of Mechanical Engineering (Department of Aeronautics, Mechanical and Electronic Convergence Engineering), Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi, Gyeongbuk, 39177, Republic of Korea
| | - Srinivas Pattipaka
- Department of Materials Science and Engineering, Pukyong National University, 45, Yongso-Ro, Nam-Gu, Busan, 48513, Republic of Korea
| | - Geon-Tae Hwang
- Department of Materials Science and Engineering, Pukyong National University, 45, Yongso-Ro, Nam-Gu, Busan, 48513, Republic of Korea
| | - Minok Park
- Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA
| | - Yu Mi Woo
- Department of Mechanical Engineering (Department of Aeronautics, Mechanical and Electronic Convergence Engineering), Kumoh National Institute of Technology, 61, Daehak-Ro, Gumi, Gyeongbuk, 39177, Republic of Korea
| | - Young Bin Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-Ro, Yuseong-Gu, Daejeon, 34141, Republic of Korea
| | - Han Eol Lee
- Division of Advanced Materials Engineering, Jeonbuk National University, Jeonju, 54896, Jeonbuk, Republic of Korea
| | - Chang Kyu Jeong
- Division of Advanced Materials Engineering, Jeonbuk National University, Jeonju, 54896, Jeonbuk, Republic of Korea
| | - Tiandong Zhang
- School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, 150080, People's Republic of China
- Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Harbin University of Science and Technology, Harbin, 150080, People's Republic of China
| | - Yuho Min
- Department of Materials Science and Metallurgical Engineering, Kyungpook National University, 80 Daehak-Ro, Buk-Gu, Daegu, 41566, Republic of Korea
| | - Kwi-Il Park
- Department of Materials Science and Metallurgical Engineering, Kyungpook National University, 80 Daehak-Ro, Buk-Gu, Daegu, 41566, Republic of Korea.
| | - Keon Jae Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-Ro, Yuseong-Gu, Daejeon, 34141, Republic of Korea.
| | - Jungho Ryu
- School of Materials Science and Engineering, Yeungnam University, Daehak-Ro, Gyeongsan-Si, 38541, Gyeongsangbuk-do, Republic of Korea.
| |
Collapse
|
5
|
Naz A, Meng Y, Luo J, Khan IA, Abbas R, Yu S, Wei J. Cutting-Edge Perovskite-Based Flexible Pressure Sensors Made Possible by Piezoelectric Innovation. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4196. [PMID: 39274586 PMCID: PMC11395823 DOI: 10.3390/ma17174196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 08/10/2024] [Accepted: 08/19/2024] [Indexed: 09/16/2024]
Abstract
In the area of flexible electronics, pressure sensors are a widely utilized variety of flexible electronics that are both indispensable and prevalent. The importance of pressure sensors in various fields is currently increasing, leading to the exploration of materials with unique structural and piezoelectric properties. Perovskite-based materials are ideal for use as flexible pressure sensors (FPSs) due to their flexibility, chemical composition, strain tolerance, high piezoelectric and piezoresistive properties, and potential integration with other technologies. This article presents a comprehensive study of perovskite-based materials used in FPSs and discusses their components, performance, and applications in detecting human movement, electronic skin, and wireless monitoring. This work also discusses challenges like material instability, durability, and toxicity, the limited widespread application due to environmental factors and toxicity concerns, and complex fabrication and future directions for perovskite-based FPSs, providing valuable insights for researchers in structural health monitoring, physical health monitoring, and industrial applications.
Collapse
Affiliation(s)
- Adeela Naz
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Yuan Meng
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Jingjing Luo
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Imtiaz Ahmad Khan
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Rimsha Abbas
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Suzhu Yu
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| | - Jun Wei
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
- State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology (Shenzhen), Shenzhen 518055, China
| |
Collapse
|
6
|
Zhu Y, Hu X, Yan X, Ni W, Wu M, Liu J. Nanoengineering Ultrathin Flexible Pressure Sensors with Superior Sensitivity and Wide Range via Nanocomposite Structures. ACS Sens 2024; 9:4176-4185. [PMID: 38967386 DOI: 10.1021/acssensors.4c01171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/06/2024]
Abstract
Flexible pressure sensors have attracted great interest due to their bendable, stretchable, and lightweight characteristics compared to rigid pressure sensors. However, the contradictions among sensitivity, detection limit, thickness, and detection range restrict the performance of flexible pressure sensors and the scope of their applications, especially for scenarios requiring conformal fitting, such as rough surfaces such as the human skin. This paper proposes a novel flexible pressure sensor by combining the nanoengineering strategy and nanocomposite structures. The nanoengineering strategy utilizes the bending deformation of nanofilm instead of the compression of the active layer to achieve super high sensitivity and low detection limit; meanwhile, the nanocomposite structures introduce distributed microbumps that delay the adhesion of nanofilm to enlarge the detection range. As a result, this device not only ensures an ultrathin thickness of 1.6 μm and a high sensitivity of 84.29 kPa-1 but also offers a large detection range of 20 kPa and an ultralow detection limit of 0.07 Pa. Owing to the ultrathin thickness as well as high performance, this device promotes applications in detecting fingertip pressure, flexible mechanical gripping, and so on, and demonstrates significant potential in wearable electronics, human-machine interaction, health monitoring, and tactile perception. This device offers a strategy to resolve the conflicts among thickness, sensitivity, detection limit, and detection range; therefore, it will advance the development of flexible pressure sensors and contribute to the community and other related research fields.
Collapse
Affiliation(s)
- Yike Zhu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| | - Xiaoguang Hu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| | - Xinran Yan
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| | - Weiyao Ni
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| | - Mengxi Wu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| | - Junshan Liu
- State Key Laboratory of High-performance Precision Manufacturing, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, Liaoning, China
| |
Collapse
|
7
|
Yao G, Gan X, Lin Y. Flexible self-powered bioelectronics enables personalized health management from diagnosis to therapy. Sci Bull (Beijing) 2024; 69:2289-2306. [PMID: 38821746 DOI: 10.1016/j.scib.2024.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 04/20/2024] [Accepted: 05/13/2024] [Indexed: 06/02/2024]
Abstract
Flexible self-powered bioelectronics (FSPBs), incorporating flexible electronic features in biomedical applications, have revolutionized the human-machine interface since they hold the potential to offer natural and seamless human interactions while overcoming the limitations of battery-dependent power sources. Furthermore, as biosensors or actuators, FSPBs can dynamically monitor physiological signals to reveal real-time health abnormalities and provide timely and precise treatments. Therefore, FSPBs are increasingly shaping the landscape of health monitoring and disease treatment, weaving a sophisticated and personalized bond between humans and health management. Here, we examine the recent advanced progress of FSPBs in developing working mechanisms, design strategies, and structural configurations toward personalized health management, emphasizing its role in clinical medical scenarios from biophysical/biochemical sensors for sensing diagnosis to robust/biodegradable actuators for intervention therapy. Future perspectives on the challenges and opportunities in emerging multifunctional FSPBs for the next-generation health management systems are also forecasted.
Collapse
Affiliation(s)
- Guang Yao
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China; State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China; Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Shenzhen 518110, China.
| | - Xingyi Gan
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China
| | - Yuan Lin
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu 610054, China; State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, China; Medico-Engineering Cooperation on Applied Medicine Research Center, University of Electronic Science and Technology of China, Chengdu 610054, China.
| |
Collapse
|
8
|
Lin G, Lu D, Cui B, Lin A, Liu M, Ye Y. Establishment of a Mass Concrete Strength-Monitoring Method Using Barium Titanate-Bismuth Ferrite/Polyvinylidene Fluoride Nanocomposite Piezoelectric Sensors with Temperature Stability. SENSORS (BASEL, SWITZERLAND) 2024; 24:4653. [PMID: 39066050 PMCID: PMC11280568 DOI: 10.3390/s24144653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/02/2024] [Accepted: 07/08/2024] [Indexed: 07/28/2024]
Abstract
Mass concrete is widely used in large-scale projects, including metro upper cover structures, water conservancy dams, and heavy equipment foundations, among others, necessitating the process of health monitoring in mass concrete construction. The development of reliable and simple strength-monitoring methods for mass concrete is challenging because the inner temperature of mass concrete is high and changes a lot. This study proposes a strength-monitoring approach for mass concrete using barium titanate-bismuth ferrite/polyvinylidene fluoride (BT-BFO/PVDF) nanocomposite piezoelectric sensors, wherein the new sensors are embedded as actuators and sensors in mass concrete. The stress wave generated by the BT-BFO/PVDF piezoelectric sensors is used to monitor the specimen's strength for 28 days. The piezoelectric voltage received by the sensors in mass concrete is analyzed. The experimental results indicate that the signal received by the BT-BFO/PVDF sensors is not easily affected by the internal temperature of mass concrete compared with that of the traditional PVDF piezoelectric sensors. The signal parameters sensitive to concrete strength variation and the change trend of concrete strength are closely related to the piezoelectric voltage. Therefore, the proposed approach using BT-BFO/PVDF nanocomposite piezoelectric sensors is efficient (error < 10%) in mass concrete monitoring. Moreover, the monitoring results do not need temperature compensation. The physical meaning of the obtained strength prediction formula is proposed. An experimental system based on PVDF dynamic strain-sensing characteristics is established.
Collapse
Affiliation(s)
- Guoliang Lin
- Fujian Provincial Key Laboratory of Advanced Technology and Information in Civil Engineering, Fuzhou 350118, China; (G.L.); (D.L.)
| | - Dongwang Lu
- Fujian Provincial Key Laboratory of Advanced Technology and Information in Civil Engineering, Fuzhou 350118, China; (G.L.); (D.L.)
| | - Bowen Cui
- College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou 350118, China; (B.C.); (M.L.)
| | - Aoxiang Lin
- College of Civil Engineering, Fuzhou University, Fuzhou 350118, China
| | - Minyi Liu
- College of Ecological Environment and Urban Construction, Fujian University of Technology, Fuzhou 350118, China; (B.C.); (M.L.)
| | | |
Collapse
|
9
|
Gao M, Luo Y, Li W, Zheng L, Pei Y. In vitro and in vivo biocompatibility assessment of chalcogenide thermoelectrics as implants. J Mater Chem B 2024; 12:6847-6855. [PMID: 38904190 DOI: 10.1039/d4tb00973h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
The ability of thermoelectric materials to generate electricity in response to local temperature gradients makes them a potentially promising solution for the regulation of cellular functions and reconstruction of tissues. Biocompatibility of implants is a crucial attribute for the successful integration of thermoelectric techniques in biomedical applications. This work focuses on the in vitro and in vivo evaluation of biocompatibility for 12 typical chalcogenide thermoelectrics, which are composed of biocompatible elements. Ag2Se, SnSe, Bi2Se3, Bi2Te2.88Se0.12 and Bi2Te3, each with a released ion concentration lower than 10 ppm in extracts, exhibited favorable biocompatibility, including cell viability, adhesion, and hemocompatibility, as observed in initial in vitro assessments. Moreover, in vivo biocompatibility assessment, achieved by hematological and histopathological analyses in the rat subcutaneous model, further substantiated the biocompatibility of Ag2Se, Bi2Se3, and Bi2Te3, with each possessing superior thermoelectric performance at room temperature. This work offers robust evidence to promote Ag2Se, Bi2Se3, and Bi2Te3 as potential thermoelectric biomaterials, establishing a foundation for their future applications in biomedicine.
Collapse
Affiliation(s)
- Mingyuan Gao
- Interdisciplinary Materials Research Center, School of Materials Science and Engineering, Tongji Univ., 4800 Caoan Rd., Shanghai 201804, China.
| | - Yiping Luo
- Department of Orthopedics, Shanghai Tenth People's Hospital, School of Medicine, Tongji Univ., 301 Yanchang Rd., Shanghai 200072, China.
- Orthopedic Intelligent Minimally Invasive Diagnosis and Treatment Center, Shanghai Tenth People's Hospital, School of Medicine, Tongji Univ., 301 Yanchang Rd., Shanghai 200072, China
| | - Wen Li
- Interdisciplinary Materials Research Center, School of Materials Science and Engineering, Tongji Univ., 4800 Caoan Rd., Shanghai 201804, China.
| | - Longpo Zheng
- Department of Orthopedics, Shanghai Tenth People's Hospital, School of Medicine, Tongji Univ., 301 Yanchang Rd., Shanghai 200072, China.
- Orthopedic Intelligent Minimally Invasive Diagnosis and Treatment Center, Shanghai Tenth People's Hospital, School of Medicine, Tongji Univ., 301 Yanchang Rd., Shanghai 200072, China
| | - Yanzhong Pei
- Interdisciplinary Materials Research Center, School of Materials Science and Engineering, Tongji Univ., 4800 Caoan Rd., Shanghai 201804, China.
| |
Collapse
|
10
|
Li J, Chu H, Chen Z, Yiu CK, Qu Q, Li Z, Yu X. Recent Advances in Materials, Devices and Algorithms Toward Wearable Continuous Blood Pressure Monitoring. ACS NANO 2024; 18:17407-17438. [PMID: 38923501 DOI: 10.1021/acsnano.4c04291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Continuous blood pressure (BP) tracking provides valuable insights into the health condition and functionality of the heart, arteries, and overall circulatory system of humans. The rapid development in flexible and wearable electronics has significantly accelerated the advancement of wearable BP monitoring technologies. However, several persistent challenges, including limited sensing capabilities and stability of flexible sensors, poor interfacial stability between sensors and skin, and low accuracy in BP estimation, have hindered the progress in wearable BP monitoring. To address these challenges, comprehensive innovations in materials design, device development, system optimization, and modeling have been pursued to improve the overall performance of wearable BP monitoring systems. In this review, we highlight the latest advancements in flexible and wearable systems toward continuous noninvasive BP tracking with a primary focus on materials development, device design, system integration, and theoretical algorithms. Existing challenges, potential solutions, and further research directions are also discussed to provide theoretical and technical guidance for the development of future wearable systems in continuous ambulatory BP measurement with enhanced sensing capability, robustness, and long-term accuracy.
Collapse
Affiliation(s)
- Jian Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Hongwei Chu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory of Flexible Printed Electronics Technology, School of Science, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China
| | - Zhenlin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Chun Ki Yiu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Qing'ao Qu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Zhiyuan Li
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xinge Yu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen 518057, China
- Hong Kong Institute for Clean Energy, City University of Hong Kong, Kowloon, Hong Kong, China
| |
Collapse
|
11
|
Hui X, Tang L, Zhang D, Yan S, Li D, Chen J, Wu F, Wang ZL, Guo H. Acoustically Enhanced Triboelectric Stethoscope for Ultrasensitive Cardiac Sounds Sensing and Disease Diagnosis. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2401508. [PMID: 38747492 DOI: 10.1002/adma.202401508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 05/02/2024] [Indexed: 05/21/2024]
Abstract
Electronic stethoscope used to detect cardiac sounds that contain essential clinical information is a primary tool for diagnosis of various cardiac disorders. However, the linear electromechanical constitutive relation makes conventional piezoelectric sensors rather ineffective to detect low-intensity, low-frequency heart acoustic signal without the assistance of complex filtering and amplification circuits. Herein, it is found that triboelectric sensor features superior advantages over piezoelectric one for microquantity sensing originated from the fast saturated constitutive characteristic. As a result, the triboelectric sensor shows ultrahigh sensitivity (1215 mV Pa-1) than the piezoelectric counterpart (21 mV Pa-1) in the sound pressure range of 50-80 dB under the same testing condition. By designing a trumpet-shaped auscultatory cavity with a power function cross-section to achieve acoustic energy converging and impedance matching, triboelectric stethoscope delivers 36 dB signal-to-noise ratio for human test (2.3 times of that for piezoelectric one). Further combining with machine learning, five cardiac states can be diagnosed at 97% accuracy. In general, the triboelectric sensor is distinctly unique in basic mechanism, provides a novel design concept for sensing micromechanical quantities, and presents significant potential for application in cardiac sounds sensing and disease diagnosis.
Collapse
Affiliation(s)
- Xindan Hui
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
- School of Physics, Chongqing University, Chongqing, 400044, China
| | - Lirong Tang
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
- School of Physics, Chongqing University, Chongqing, 400044, China
| | - Dewen Zhang
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
| | - Shanlin Yan
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
| | - Dongxiao Li
- Department of Electrical and Computer Engineering, National University of Singapore, Singapore, 117583, Singapore
| | - Jie Chen
- College of Physics and Electronic Engineering, Chongqing Normal University, Chongqing, 401331, China
| | - Fei Wu
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 100083, China
| | - Hengyu Guo
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing, 400044, China
- School of Physics, Chongqing University, Chongqing, 400044, China
| |
Collapse
|
12
|
Zheng W, Li T, Jin F, Qian L, Ma J, Wei Z, Ma X, Wang F, Sun J, Yuan T, Wang T, Feng ZQ. Interfacial Polarization Locked Flexible β-Phase Glycine/Nb 2CT x Piezoelectric Nanofibers. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2308715. [PMID: 38412419 DOI: 10.1002/smll.202308715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/24/2023] [Indexed: 02/29/2024]
Abstract
Biomolecular piezoelectric materials show great potential in the field of wearable and implantable biomedical devices. Here, a self-assemble approach is developed to fabricating flexible β-glycine piezoelectric nanofibers with interfacial polarization locked aligned crystal domains induced by Nb2CTx nanosheets. Acted as an effective nucleating agent, Nb2CTx nanosheets can induce glycine to crystallize from edges toward flat surfaces on its 2D crystal plane and form a distinctive eutectic structure within the nanoconfined space. The interfacial polarization locking formed between O atom on glycine and Nb atom on Nb2CTx is essential to align the β-glycine crystal domains with (001) crystal plane intensity extremely improved. This β-phase glycine/Nb2CTx nanofibers (Gly-Nb2C-NFs) exhibit fabulous mechanical flexibility with Young's modulus of 10 MPa, and an enhanced piezoelectric coefficient of 5.0 pC N-1 or piezoelectric voltage coefficient of 129 × 10-3Vm N-1. The interface polarization locking greatly improves the thermostability of β-glycine before melting (≈210°C). A piezoelectric sensor based on this Gly-Nb2C-NFs is used for micro-vibration sensing in vivo in mice and exhibits excellent sensing ability. This strategy provides an effective approach for the regular crystallization modulation for glycine crystals, opening a new avenue toward the design of piezoelectric biomolecular materials induced by 2D materials.
Collapse
Affiliation(s)
- Weiying Zheng
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Tong Li
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Fei Jin
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Lili Qian
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Juan Ma
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Zhidong Wei
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Xiying Ma
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Fuyi Wang
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Jiangtao Sun
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| | - Tao Yuan
- Department of Orthopedics,Jinling Hospital, Nanjing University, School of Medicine, Nanjing, 210002, P. R. China
| | - Ting Wang
- State Key Laboratory of Digital Medical Engineering, Southeast University, Nanjing, 210096, P. R. China
| | - Zhang-Qi Feng
- School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing, 210094, P. R. China
| |
Collapse
|
13
|
Gao Z, Zhou Y, Zhang J, Foroughi J, Peng S, Baughman RH, Wang ZL, Wang CH. Advanced Energy Harvesters and Energy Storage for Powering Wearable and Implantable Medical Devices. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2404492. [PMID: 38935237 DOI: 10.1002/adma.202404492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 06/21/2024] [Indexed: 06/28/2024]
Abstract
Wearable and implantable active medical devices (WIMDs) are transformative solutions for improving healthcare, offering continuous health monitoring, early disease detection, targeted treatments, personalized medicine, and connected health capabilities. Commercialized WIMDs use primary or rechargeable batteries to power their sensing, actuation, stimulation, and communication functions, and periodic battery replacements of implanted active medical devices pose major risks of surgical infections or inconvenience to users. Addressing the energy source challenge is critical for meeting the growing demand of the WIMD market that is reaching valuations in the tens of billions of dollars. This review critically assesses the recent advances in energy harvesting and storage technologies that can potentially eliminate the need for battery replacements. With a key focus on advanced materials that can enable energy harvesters to meet the energy needs of WIMDs, this review examines the crucial roles of advanced materials in improving the efficiencies of energy harvesters, wireless charging, and energy storage devices. This review concludes by highlighting the key challenges and opportunities in advanced materials necessary to achieve the vision of self-powered wearable and implantable active medical devices, eliminating the risks associated with surgical battery replacement and the inconvenience of frequent manual recharging.
Collapse
Affiliation(s)
- Ziyan Gao
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Yang Zhou
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Jin Zhang
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Javad Foroughi
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Shuhua Peng
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Ray H Baughman
- Alan G. MacDiarmid NanoTech Institute, The University of Texas at Dallas, Richardson, TX, 75080, USA
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing, 101400, P. R. China
| | - Chun H Wang
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| |
Collapse
|
14
|
Cao C, Zhou P, Wang J, Liu M, Wang P, Qi Y, Zhang T. Ultrahigh sensitive and rapid-response self-powered flexible pressure sensor based on sandwiched piezoelectric composites. J Colloid Interface Sci 2024; 664:902-915. [PMID: 38493655 DOI: 10.1016/j.jcis.2024.03.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/08/2024] [Accepted: 03/13/2024] [Indexed: 03/19/2024]
Abstract
Flexible sensors and actuators are the basis for realizing the Internet of Everything. This study identifies specific interfacial polarization and filler dispersion challenges in flexible sensors. A novel sandwich-structured flexible sensor with polydimethylsiloxane (PDMS)-filled Nb2CTx as the interlayer and poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)]-filled barium titanate (BTO) as the upper and lower layers was designed and fabricated. The thickness of the interlayer was optimized to be 6.2 μm, resulting in an ultrahigh sensitivity of 16.05 V/N and ultrashort response time of 626 μs. The interlayer achieved an oriented arrangement of the dipoles in the upper and lower piezoelectric films through interfacial polarization, enhancing the piezoelectric output and sensitivity. The proposed mechanism was confirmed by the dielectric properties, local piezoelectric response, cross-sectional potential simulation, and interfacial electrical calculations. Additionally, the sensor effectively distinguishes various body movements, facial micro-expressions, and throat vibrations during vocalization, and can be applied to ultrahigh-sensitive self-powered flexible piezoelectric pressure sensors.
Collapse
Affiliation(s)
- Chuan Cao
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China
| | - Peng Zhou
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China
| | - Jianqiao Wang
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China
| | - Miaoxuan Liu
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China
| | - Peng Wang
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China
| | - Yajun Qi
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China.
| | - Tianjin Zhang
- Ministry of Education Key Laboratory for Green Preparation and Application of Functional Materials, Hubei Provincial Key Laboratory of Polymers, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, School of Materials Science and Engineering, Hubei University, Wuhan 430062, PR China.
| |
Collapse
|
15
|
Liu LF, Li T, Lai QT, Tang G, Sun QJ. Recent Advances in Self-Powered Tactile Sensing for Wearable Electronics. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2493. [PMID: 38893757 PMCID: PMC11172942 DOI: 10.3390/ma17112493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/16/2024] [Accepted: 05/20/2024] [Indexed: 06/21/2024]
Abstract
With the arrival of the Internet of Things era, the demand for tactile sensors continues to grow. However, traditional sensors mostly require an external power supply to meet real-time monitoring, which brings many drawbacks such as short service life, environmental pollution, and difficulty in replacement, which greatly limits their practical applications. Therefore, the development of a passive self-power supply of tactile sensors has become a research hotspot in academia and the industry. In this review, the development of self-powered tactile sensors in the past several years is introduced and discussed. First, the sensing principle of self-powered tactile sensors is introduced. After that, the main performance parameters of the tactile sensors are briefly discussed. Finally, the potential application prospects of the tactile sensors are discussed in detail.
Collapse
Affiliation(s)
| | | | | | | | - Qi-Jun Sun
- School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou 510006, China (G.T.)
| |
Collapse
|
16
|
Zu W, Carranza HE, Bartlett MD. Enhancing Electrical Conductivity of Stretchable Liquid Metal-Silver Composites through Direct Ink Writing. ACS APPLIED MATERIALS & INTERFACES 2024; 16. [PMID: 38685822 PMCID: PMC11082841 DOI: 10.1021/acsami.4c02466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/11/2024] [Accepted: 04/18/2024] [Indexed: 05/02/2024]
Abstract
Structure-property-process relationships are a controlling factor in the performance of materials. This offers opportunities in emerging areas, such as stretchable conductors, to control process conditions during printing to enhance performance. Herein, by systematically tuning direct ink write (DIW) process parameters, the electrical conductivity of multiphase liquid metal (LM)-silver stretchable conductors is increased by a maximum of 400% to over 1.06 × 106 S·m-1. This is achieved by modulating the DIW print velocity, which enables the in situ elongation, coalescence, and percolation of these multiphase inclusions during printing. These DIW printed filaments are conductive as fabricated and are soft (modulus as low as 1.1 MPa), stretchable (strain limit >800%), and show strain invariant conductivity up to 80% strain. These capabilities are demonstrated through a set of electromagnetic induction coils that can transfer power wirelessly through air and water, even under deformation. This work provides a methodology to program properties in stretchable conductors, where the combination of material composition and process parameters leads to greatly enhanced performance. This approach can find use in applications such as soft robots, soft electronics, and printed materials for deformable, yet highly functional devices.
Collapse
Affiliation(s)
- Wuzhou Zu
- Mechanical
Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Hugo E. Carranza
- Mechanical
Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Michael D. Bartlett
- Mechanical
Engineering, Soft Materials and Structures Lab, Virginia Tech, Blacksburg, Virginia 24061, United States
- Macromolecules
Innovation Institute, Virginia Tech, Blacksburg, Virginia 24061, United States
| |
Collapse
|
17
|
Fan W, Lei R, Dou H, Wu Z, Lu L, Wang S, Liu X, Chen W, Rezakazemi M, Aminabhavi TM, Li Y, Ge S. Sweat permeable and ultrahigh strength 3D PVDF piezoelectric nanoyarn fabric strain sensor. Nat Commun 2024; 15:3509. [PMID: 38664454 PMCID: PMC11045766 DOI: 10.1038/s41467-024-47810-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 04/10/2024] [Indexed: 04/28/2024] Open
Abstract
Commercial wearable piezoelectric sensors possess excellent anti-interference stability due to their electronic packaging. However, this packaging renders them barely breathable and compromises human comfort. To address this issue, we develop a PVDF piezoelectric nanoyarns with an ultrahigh strength of 313.3 MPa, weaving them with different yarns to form three-dimensional piezoelectric fabric (3DPF) sensor using the advanced 3D textile technology. The tensile strength (46.0 MPa) of 3DPF exhibits the highest among the reported flexible piezoelectric sensors. The 3DPF features anti-gravity unidirectional liquid transport that allows sweat to move from the inner layer near to the skin to the outer layer in 4 s, resulting in a comfortable and dry environment for the user. It should be noted that sweating does not weaken the piezoelectric properties of 3DPF, but rather enhances. Additionally, the durability and comfortability of 3DPF are similar to those of the commercial cotton T-shirts. This work provides a strategy for developing comfortable flexible wearable electronic devices.
Collapse
Affiliation(s)
- Wei Fan
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China.
| | - Ruixin Lei
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China
| | - Hao Dou
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China
| | - Zheng Wu
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China
| | - Linlin Lu
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China
| | - Shujuan Wang
- School of Chemistry, Xi'an Jiaotong University, Xi'an, China
| | - Xuqing Liu
- State Key Laboratory of Solidification Processing, Center of Advanced Lubrication and Seal Materials, School of Materials Science and Engineering, Northwestern Polytechnical University, Xi'an, China
| | - Weichun Chen
- School of Textile Science and Engineering, Key Laboratory of Functional Textile Material and Product of Ministry of Education, Institute of Flexible electronics and Intelligent Textile, Xi'an Polytechnic University, Xi'an, Shaanxi, China
| | - Mashallah Rezakazemi
- Faculty of Chemical and Materials Engineering, Shahrood University of Technology, Shahrood, Iran.
| | - Tejraj M Aminabhavi
- Center for Energy and Environment, School of Advanced Sciences, KLE Technological University, Hubballi, India and Korea University, Seoul, Republic of Korea
| | - Yi Li
- Department of Materials, University of Manchester, Oxford Road, Manchester, UK
| | - Shengbo Ge
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, China.
| |
Collapse
|
18
|
Xu C, Chen J, Zhu Z, Liu M, Lan R, Chen X, Tang W, Zhang Y, Li H. Flexible Pressure Sensors in Human-Machine Interface Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2306655. [PMID: 38009791 DOI: 10.1002/smll.202306655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 10/30/2023] [Indexed: 11/29/2023]
Abstract
Flexible sensors are highly flexible, malleable, and capable of adapting todifferent shapes, surfaces, and environments, which opens a wide range ofpotential applications in the field of human-machine interface (HMI). Inparticular, flexible pressure sensors as a crucial member of the flexiblesensor family, are widely used in wearable devices, health monitoringinstruments, robots and other fields because they can achieve accuratemeasurement and convert the pressure into electrical signals. The mostintuitive feeling that flexible sensors bring to people is the change ofhuman-machine interface interaction, from the previous rigid interaction suchas keyboard and mouse to flexible interaction such as smart gloves, more inline with people's natural control habits. Many advanced flexible pressuresensors have emerged through extensive research and development, and to adaptto various fields of application. Researchers have been seeking to enhanceperformance of flexible pressure sensors through improving materials, sensingmechanisms, fabrication methods, and microstructures. This paper reviews the flexible pressure sensors in HMI in recent years, mainlyincluding the following aspects: current cutting-edge flexible pressuresensors; sensing mechanisms, substrate materials and active materials; sensorfabrication, performances, and their optimization methods; the flexiblepressure sensors for various HMI applications and their prospects.
Collapse
Affiliation(s)
- Chengsheng Xu
- College of Big Data and Internet, Shenzhen Technology University, Shenzhen, Guangdong, 518118, China
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Jing Chen
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Zhengfang Zhu
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Moran Liu
- College of Big Data and Internet, Shenzhen Technology University, Shenzhen, Guangdong, 518118, China
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Ronghua Lan
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Xiaohong Chen
- Department of Infertility and Sexual Medicine, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, 510630, China
| | - Wei Tang
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| | - Yan Zhang
- Department of Infertility and Sexual Medicine, The Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, 510630, China
| | - Hui Li
- College of Big Data and Internet, Shenzhen Technology University, Shenzhen, Guangdong, 518118, China
- Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China
| |
Collapse
|
19
|
Zhang J, Zhu P, Ouyang H, Wang E, Xue J, Li Z, Shi B, Fan Y. High Signal to Noise Ratio Piezoelectric Thin Film Sensor Based on Elastomer Amplification for Ambulatory Blood Pressure Monitoring. ACS Sens 2024; 9:1301-1309. [PMID: 38373043 DOI: 10.1021/acssensors.3c02180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
Continuous pulse wave detection can be used for monitoring and diagnosing cardiovascular diseases, and research on pulse sensing based on piezoelectric thin films is one of the hot spots. Usually, piezoelectric thin films do not come into direct contact with the skin and need to be connected through a layer of an elastic medium. Most views think that the main function of this layer of elastic medium is to increase the adhesion between the sensor component and the skin, but there is little discussion about the impact of the elastic medium on pulse vibration transmission. Here, we conducted a detailed study on the effects of Young's modulus and the thickness of elastic media on pulse sensing signals. The results show that the waveform amplitude of the piezoelectric sensing signal decreases with the increase of Young's modulus and thickness of the elastic medium. Then, we constructed a theoretical model of the influence of elastic media on pulse wave propagation. The amplitude of the pulse wave signal detected by the optimized sensor was increased to 480%. Our research shows that by regulating Young's modulus and thickness of elastic media, pulse wave signals can undergo a similar amplification effect, which has an important theoretical reference value for achieving ambulatory blood pressure monitoring based on high-quality pulse waves.
Collapse
Affiliation(s)
- Jiasi Zhang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing 100191, China
| | - Pengrui Zhu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing 100191, China
| | - Han Ouyang
- School of Nanoscience and Engineering, University of Chinese Academy of Sciences, Beijing 101408, China
| | - Engui Wang
- School of Nanoscience and Engineering, University of Chinese Academy of Sciences, Beijing 101408, China
| | - Jiangtao Xue
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China
| | - Zhou Li
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China
| | - Bojing Shi
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing 100191, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medicine, Beihang University, Beijing 100191, China
| |
Collapse
|
20
|
Farzin MA, Naghib SM, Rabiee N. Advancements in Bio-inspired Self-Powered Wireless Sensors: Materials, Mechanisms, and Biomedical Applications. ACS Biomater Sci Eng 2024; 10:1262-1301. [PMID: 38376103 DOI: 10.1021/acsbiomaterials.3c01633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
The rapid maturation of smart city ecosystems is intimately linked to advances in the Internet of Things (IoT) and self-powered sensing technologies. Central to this evolution are battery-less sensors that are critical for applications such as continuous health monitoring through blood metabolites and vital signs, the recognition of human activity for behavioral analysis, and the operational enhancement of humanoid robots. The focus on biosensors that exploit the human body for energy-spanning wearable, attachable, and implantable variants has intensified, driven by their broad applicability in areas from underwater exploration to biomedical assays and earthquake monitoring. The heart of these sensors lies in their diverse energy harvesting mechanisms, including biofuel cells, and piezoelectric, triboelectric, and pyroelectric nanogenerators. Notwithstanding the wealth of research, the literature still lacks a holistic review that integrates the design challenges and implementation intricacies of such sensors. Our review seeks to fill this gap by thoroughly evaluating energy harvesting strategies from both material and structural perspectives and assessing their roles in powering an array of sensors for myriad uses. This exploration offers a comprehensive outlook on the state of self-powered sensing devices, tackling the nuances of their deployment and highlighting their potential to revolutionize data gathering in autonomous systems. The intent of this review is to chart the current landscape and future prospects, providing a pivotal reference point for ongoing research and innovation in self-powered wireless sensing technologies.
Collapse
Affiliation(s)
- Mohammad Ali Farzin
- Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology, P.O. Box 16846-13114, Tehran 13114-16846, Iran
| | - Seyed Morteza Naghib
- Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology, P.O. Box 16846-13114, Tehran 13114-16846, Iran
| | - Navid Rabiee
- Centre for Molecular Medicine and Innovative Therapeutics, Murdoch University, Perth, WA 6150, Australia
| |
Collapse
|
21
|
Kumi M, Wang T, Ejeromedoghene O, Wang J, Li P, Huang W. Exploring the Potentials of Chitin and Chitosan-Based Bioinks for 3D-Printing of Flexible Electronics: The Future of Sustainable Bioelectronics. SMALL METHODS 2024:e2301341. [PMID: 38403854 DOI: 10.1002/smtd.202301341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Indexed: 02/27/2024]
Abstract
Chitin and chitosan-based bioink for 3D-printed flexible electronics have tremendous potential for innovation in healthcare, agriculture, the environment, and industry. This biomaterial is suitable for 3D printing because it is highly stretchable, super-flexible, affordable, ultrathin, and lightweight. Owing to its ease of use, on-demand manufacturing, accurate and regulated deposition, and versatility with flexible and soft functional materials, 3D printing has revolutionized free-form construction and end-user customization. This study examined the potential of employing chitin and chitosan-based bioinks to build 3D-printed flexible electronic devices and optimize bioink formulation, printing parameters, and postprocessing processes to improve mechanical and electrical properties. The exploration of 3D-printed chitin and chitosan-based flexible bioelectronics will open new avenues for new flexible materials for numerous industrial applications.
Collapse
Affiliation(s)
- Moses Kumi
- Frontiers Science Center for Flexible Electronics (FSCFE), Xi'an Institute of Flexible Electronics (IFE), Xi'an Institute of Biomedical Materials and Engineering (IBME), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, Shaanxi, 710072, P. R. China
| | - Tengjiao Wang
- Frontiers Science Center for Flexible Electronics (FSCFE), Xi'an Institute of Flexible Electronics (IFE), Xi'an Institute of Biomedical Materials and Engineering (IBME), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, Shaanxi, 710072, P. R. China
| | - Onome Ejeromedoghene
- College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, Jiangsu, 215123, P. R. China
| | - Junjie Wang
- Frontiers Science Center for Flexible Electronics (FSCFE), Xi'an Institute of Flexible Electronics (IFE), Xi'an Institute of Biomedical Materials and Engineering (IBME), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, Shaanxi, 710072, P. R. China
| | - Peng Li
- Frontiers Science Center for Flexible Electronics (FSCFE), Xi'an Institute of Flexible Electronics (IFE), Xi'an Institute of Biomedical Materials and Engineering (IBME), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, Shaanxi, 710072, P. R. China
| | - Wei Huang
- Frontiers Science Center for Flexible Electronics (FSCFE), Xi'an Institute of Flexible Electronics (IFE), Xi'an Institute of Biomedical Materials and Engineering (IBME), Northwestern Polytechnical University (NPU), 127 West Youyi Road, Xi'an, Shaanxi, 710072, P. R. China
| |
Collapse
|
22
|
He Y, Goay ACY, Yuen ACY, Mishra D, Zhou Y, Lu T, Wang D, Liu Y, Boyer C, Wang CH, Zhang J. Bulk Schottky Junctions-Based Flexible Triboelectric Nanogenerators to Power Backscatter Communications in Green 6G Networks. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2305829. [PMID: 38039442 PMCID: PMC10870046 DOI: 10.1002/advs.202305829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 10/21/2023] [Indexed: 12/03/2023]
Abstract
This work introduces a novel method to construct Schottky junctions to boost the output performance of triboelectric nanogenerators (TENGs). Perovskite barium zirconium titanate (BZT) core/metal silver shell nanoparticles are synthesized to be embedded into electrospun polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) nanofibers before they are used as tribo-negative layers. The output power of TENGs with composite fiber mat exhibited >600% increase compared to that with neat polymer fiber mat. The best TENG achieved 1339 V in open-circuit voltage, 40 µA in short-circuit current and 47.9 W m-2 in power density. The Schottky junctions increased charge carrier density in tribo-layers, ensuring a high charge transfer rate while keeping the content of conductive fillers low, thus avoiding charge loss and improving performance. These TENGs are utilized to power radio frequency identification (RFID) tags for backscatter communication (BackCom) systems, enabling ultra-massive connectivity in the 6G wireless networks and reducing information communications technology systems' carbon footprint. Specifically, TENGs are used to provide an additional energy source to the passive tags. Results show that TENGs can boost power for BackCom and increase the communication range by 386%. This timely contribution offers a novel route for sustainable 6G applications by exploiting the expanded communication range of BackCom tags.
Collapse
Affiliation(s)
- Yilin He
- School of Mechanical and Manufacturing EngineeringUniversity of New South WalesBuilding J17, KensingtonSydneyNSW2052Australia
| | - Amus Chee Yuen Goay
- School of Electrical Engineering and TelecommunicationsUniversity of New South Wales330 Anzac Parade, KensingtonSydneyNSW2033Australia
| | - Anthony Chun Yin Yuen
- Department of Building Environment and Energy EngineeringThe Hong Kong Polytechnic UniversityHung HomKowloonHong Kong SAR000China
| | - Deepak Mishra
- School of Electrical Engineering and TelecommunicationsUniversity of New South Wales330 Anzac Parade, KensingtonSydneyNSW2033Australia
| | - Yang Zhou
- School of Mechanical and Manufacturing EngineeringUniversity of New South WalesBuilding J17, KensingtonSydneyNSW2052Australia
| | - Teng Lu
- Research School of ChemistryAustralian National UniversityCollege of ScienceBuilding 137, Sullivans Creek RdActonACT2601Australia
| | - Danyang Wang
- School of Materials Science and EngineeringUniversity of New South WalesHilmer Building, KensingtonSydneyNSW2052Australia
| | - Yun Liu
- Research School of ChemistryAustralian National UniversityCollege of ScienceBuilding 137, Sullivans Creek RdActonACT2601Australia
| | - Cyrille Boyer
- School of Chemical EngineeringUniversity of New South WalesBuilding E8, KensingtonSydneyNSW2052Australia
| | - Chun H. Wang
- School of Mechanical and Manufacturing EngineeringUniversity of New South WalesBuilding J17, KensingtonSydneyNSW2052Australia
| | - Jin Zhang
- School of Mechanical and Manufacturing EngineeringUniversity of New South WalesBuilding J17, KensingtonSydneyNSW2052Australia
| |
Collapse
|
23
|
Gong S, Lu Y, Yin J, Levin A, Cheng W. Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare. Chem Rev 2024; 124:455-553. [PMID: 38174868 DOI: 10.1021/acs.chemrev.3c00502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
In the era of Internet-of-things, many things can stay connected; however, biological systems, including those necessary for human health, remain unable to stay connected to the global Internet due to the lack of soft conformal biosensors. The fundamental challenge lies in the fact that electronics and biology are distinct and incompatible, as they are based on different materials via different functioning principles. In particular, the human body is soft and curvilinear, yet electronics are typically rigid and planar. Recent advances in materials and materials design have generated tremendous opportunities to design soft wearable bioelectronics, which may bridge the gap, enabling the ultimate dream of connected healthcare for anyone, anytime, and anywhere. We begin with a review of the historical development of healthcare, indicating the significant trend of connected healthcare. This is followed by the focal point of discussion about new materials and materials design, particularly low-dimensional nanomaterials. We summarize material types and their attributes for designing soft bioelectronic sensors; we also cover their synthesis and fabrication methods, including top-down, bottom-up, and their combined approaches. Next, we discuss the wearable energy challenges and progress made to date. In addition to front-end wearable devices, we also describe back-end machine learning algorithms, artificial intelligence, telecommunication, and software. Afterward, we describe the integration of soft wearable bioelectronic systems which have been applied in various testbeds in real-world settings, including laboratories that are preclinical and clinical environments. Finally, we narrate the remaining challenges and opportunities in conjunction with our perspectives.
Collapse
Affiliation(s)
- Shu Gong
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Yan Lu
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Jialiang Yin
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Arie Levin
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
| | - Wenlong Cheng
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria 3800, Australia
| |
Collapse
|
24
|
Horta-Velázquez A, Mota-Morales JD, Morales-Narváez E. Next-generation of smart dressings: Integrating multiplexed sensors and theranostic functions. Int J Biol Macromol 2024; 254:127737. [PMID: 38287589 DOI: 10.1016/j.ijbiomac.2023.127737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/18/2023] [Accepted: 10/26/2023] [Indexed: 01/31/2024]
Abstract
Non-healing wounds represent a significant burden for healthcare systems and society, giving rise to severe economic and human issues. Currently, the use of dressings and visual assessment represent the primary and standard care for wounds. Conventional dressings, like cotton gauze, provide only passive physical protection. Besides, they end up paradoxically hampering the wound-healing process by producing tissue damage and pain when removed during routine check-ups. In response to these limitations, researchers, engineers, and technologists are developing innovative dressings that incorporate advanced diagnostic and therapeutic functionalities, coined as "smart dressings". Now, the maturation of smart dressing is bringing them closer to real-life applications, leading to an exciting new generation of these devices. The next generation of smart dressings is capable of monitoring in real-time multiple biomarkers while including pro-healing capabilities in a single platform. Such multiplexed and theranostic smart dressings are expected to offer a timely biomarker-directed diagnosis of non-healing wounds while enabling rapid, automated, and personalized treatments of infection and chronicity. Herein, we provide an insightful overview of these advantageous devices, delving into the diverse spectrum of possible engineering strategies. This encompasses the use of electrochemical and optical platforms with diverse multiplexing architectures, such as multi-zone sensing arrays and multi-layered devices. Open or closed-loop theranostic mechanisms using various stimuli-responsive materials that could be internally or externally controlled are also included. Finally, a critical discussion on the main challenges and future directions of smart dressings is also offered.
Collapse
Affiliation(s)
| | - Josué D Mota-Morales
- Centro de Física Aplicada y Tecnología Avanzada (CFATA), Universidad Nacional Autónoma de México (UNAM), Querétaro 76230, Mexico
| | - Eden Morales-Narváez
- Centro de Física Aplicada y Tecnología Avanzada (CFATA), Universidad Nacional Autónoma de México (UNAM), Querétaro 76230, Mexico.
| |
Collapse
|
25
|
Wang Y, Wang X, Nie S, Meng K, Lin Z. Recent Progress of Wearable Triboelectric Nanogenerator-Based Sensor for Pulse Wave Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 24:36. [PMID: 38202897 PMCID: PMC10780409 DOI: 10.3390/s24010036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 11/24/2023] [Accepted: 12/18/2023] [Indexed: 01/12/2024]
Abstract
Today, cardiovascular diseases threaten human health worldwide. In clinical practice, it has been concluded that analyzing the pulse waveform can provide clinically valuable information for the diagnosis of cardiovascular diseases. Accordingly, continuous and accurate monitoring of the pulse wave is essential for the prevention and detection of cardiovascular diseases. Wearable triboelectric nanogenerators (TENGs) are emerging as a pulse wave monitoring biotechnology due to their compelling characteristics, including being self-powered, light-weight, and wear-resistant, as well as featuring user-friendliness and superior sensitivity. Herein, a comprehensive review is conducted on the progress of wearable TENGs for pulse wave monitoring. Firstly, the four modes of operation of TENG are briefly described. Secondly, TENGs for pulse wave monitoring are classified into two categories, namely wearable flexible film-based TENG sensors and textile-based TENG sensors. Next, the materials, fabrication methods, working mechanisms, and experimental performance of various TENG-based sensors are summarized. It concludes by comparing the characteristics of the two types of TENGs and discussing the potential development and challenges of TENG-based sensors in the diagnosis of cardiovascular diseases and personalized healthcare.
Collapse
Affiliation(s)
- Yiming Wang
- School of Electronic and Information Engineering, Southwest University, Chongqing 400715, China; (Y.W.); (X.W.); (S.N.)
| | - Xiaoke Wang
- School of Electronic and Information Engineering, Southwest University, Chongqing 400715, China; (Y.W.); (X.W.); (S.N.)
| | - Shijin Nie
- School of Electronic and Information Engineering, Southwest University, Chongqing 400715, China; (Y.W.); (X.W.); (S.N.)
| | - Keyu Meng
- School of Electronic and Information Engineering, Changchun University, Changchun 130022, China;
| | - Zhiming Lin
- School of Electronic and Information Engineering, Southwest University, Chongqing 400715, China; (Y.W.); (X.W.); (S.N.)
| |
Collapse
|
26
|
Kim MJ, Song Z, Yun TG, Kang MJ, Son DH, Pyun JC. Wearable fabric-based ZnO nanogenerator for biomechanical and biothermal monitoring. Biosens Bioelectron 2023; 242:115739. [PMID: 37826880 DOI: 10.1016/j.bios.2023.115739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/02/2023] [Accepted: 10/03/2023] [Indexed: 10/14/2023]
Abstract
Wearable devices that can mechanically conform to human skin are a necessity for reliable monitoring and decoding of biomechanical activities through skin. Most inorganic piezoelectrics, however, lack deformability and damage tolerance, impeding stable motion monitoring. Here, we present an air-permeable fabric-based ZnO nanogenerator with mechanical adaptivity to diverse deformations for wearable piezoelectric sensors, collecting biomechanical health data. We fabricate ZnO nanorods incorporated throughout the entire nylon fabric, with a strategically positioned neutral mechanical plane, for bending-sensitive electronics (2.59 μA mm). Its hierarchically interlocked geometry also permits sensitive tactile sensing (0.15 nA kPa-1). Various physiological information about activities, including pulse beating, breathing, saliva swallowing, and coughing, is attained using skin-mounted sensors. Further, the pyroelectric sensing capability of a mask-attached device is demonstrated by identifying specific respiratory patterns. Our wearable healthcare sensors hold great promise for real-time monitoring of health-related vital signs, informing individuals' health status without disrupting their daily lives.
Collapse
Affiliation(s)
- Moon-Ju Kim
- Department of Materials and Science and Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Zhiquan Song
- Department of Materials and Science and Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Tae Gyeong Yun
- Department of Materials and Science and Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Min-Jung Kang
- Korea Institute of Science and Technology, Seoul, 02792, South Korea
| | - Dong Hee Son
- Department of Chemistry, Texas A&M University, College Station, TX, 77843, United States
| | - Jae-Chul Pyun
- Department of Materials and Science and Engineering, Yonsei University, Seoul, 03722, South Korea.
| |
Collapse
|
27
|
Liu W, Wang X. Recent Advances of Nanogenerator Technology for Cardiovascular Sensing and Monitoring. NANO ENERGY 2023; 117:108910. [PMID: 39183759 PMCID: PMC11343574 DOI: 10.1016/j.nanoen.2023.108910] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/27/2024]
Abstract
Cardiovascular sensing and monitoring is a widely used function in cardiovascular devices. Nowadays, achieving desired flexibility, wearability and implantability becomes a major design goal for the advancement of this family of devices. As an emerging technology, nanogenerator (NG) offers an intriguing promise for replacing the battery, an essential obstacle toward tissue-like soft electronics. This article reviews most recent advancements in NG technology for advanced cardiovascular sensing and monitoring. Based on the application targets, the discuss covers implantable NGs on hearts, implantable NGs for blood vessel grafts and patches, and wearable NGs with various sensing functions. The applications of NGs as a power source and as an electromechanical sensing element are both discussed. At the end, current challenges in this direction and future research perspectives are elaborated. This emerging and impactful application direction reviewed in this article is expected to inspire many new research and commercialization opportunities in the field of NG technology.
Collapse
Affiliation(s)
- Wenjian Liu
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Xudong Wang
- Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
| |
Collapse
|
28
|
Lin R, Lei M, Ding S, Cheng Q, Ma Z, Wang L, Tang Z, Zhou B, Zhou Y. Applications of flexible electronics related to cardiocerebral vascular system. Mater Today Bio 2023; 23:100787. [PMID: 37766895 PMCID: PMC10519834 DOI: 10.1016/j.mtbio.2023.100787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 08/14/2023] [Accepted: 08/28/2023] [Indexed: 09/29/2023] Open
Abstract
Ensuring accessible and high-quality healthcare worldwide requires field-deployable and affordable clinical diagnostic tools with high performance. In recent years, flexible electronics with wearable and implantable capabilities have garnered significant attention from researchers, which functioned as vital clinical diagnostic-assisted tools by real-time signal transmission from interested targets in vivo. As the most crucial and complex system of human body, cardiocerebral vascular system together with heart-brain network attracts researchers inputting profuse and indefatigable efforts on proper flexible electronics design and materials selection, trying to overcome the impassable gulf between vivid organisms and rigid inorganic units. This article reviews recent breakthroughs in flexible electronics specifically applied to cardiocerebral vascular system and heart-brain network. Relevant sensor types and working principles, electronics materials selection and treatment methods are expounded. Applications of flexible electronics related to these interested organs and systems are specially highlighted. Through precedent great working studies, we conclude their merits and point out some limitations in this emerging field, thus will help to pave the way for revolutionary flexible electronics and diagnosis assisted tools development.
Collapse
Affiliation(s)
- Runxing Lin
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
- Brain Cognition and Brain Disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Ming Lei
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Sen Ding
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Quansheng Cheng
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Zhichao Ma
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai, 200240, China
| | - Liping Wang
- Brain Cognition and Brain Disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Zikang Tang
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Bingpu Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Yinning Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
- Department of Physics and Chemistry, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| |
Collapse
|
29
|
Ali F, Koc M. 3D Printed Polymer Piezoelectric Materials: Transforming Healthcare through Biomedical Applications. Polymers (Basel) 2023; 15:4470. [PMID: 38231894 PMCID: PMC10708359 DOI: 10.3390/polym15234470] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/09/2023] [Accepted: 11/13/2023] [Indexed: 01/19/2024] Open
Abstract
Three-dimensional (3D) printing is a promising manufacturing platform in biomedical engineering. It offers significant advantages in fabricating complex and customized biomedical products with accuracy, efficiency, cost-effectiveness, and reproducibility. The rapidly growing field of three-dimensional printing (3DP), which emphasizes customization as its key advantage, is actively searching for functional materials. Among these materials, piezoelectric materials are highly desired due to their linear electromechanical and thermoelectric properties. Polymer piezoelectrics and their composites are in high demand as biomaterials due to their controllable and reproducible piezoelectric properties. Three-dimensional printable piezoelectric materials have opened new possibilities for integration into biomedical fields such as sensors for healthcare monitoring, controlled drug delivery systems, tissue engineering, microfluidic, and artificial muscle actuators. Overall, this review paper provides insights into the fundamentals of polymer piezoelectric materials, the application of polymer piezoelectric materials in biomedical fields, and highlights the challenges and opportunities in realizing their full potential for functional applications. By addressing these challenges, integrating 3DP and piezoelectric materials can lead to the development of advanced sensors and devices with enhanced performance and customization capabilities for biomedical applications.
Collapse
Affiliation(s)
- Fawad Ali
- Division of Sustainable Development, College of Science and Engineering, Hamad Bin Khalifa University, Qatar Foundation, Doha 34110, Qatar;
| | | |
Collapse
|
30
|
Ren X, Yuan Y, Li J, Ling H, Chen Y, Yang P, Li J, Hu B. A gas-permeable, durable, and sensitive wearable strain sensor through thermal-radiation-promoted in situ welding. Chem Commun (Camb) 2023; 59:13595-13598. [PMID: 37888889 DOI: 10.1039/d3cc04310j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2023]
Abstract
A convenient strategy for fabricating a wearable sensor with favorable durability and sensitivity is reported. This approach exploits the reconstructed hydrogen bonds within the thermoplastic polyurethane (TPU) during the heating evaporation of metal to form robust welding of the fibers in the substrate. The sensor can steadily monitor pulse waves and facilitate real-time human-machine interaction.
Collapse
Affiliation(s)
- Xueyang Ren
- State Key Laboratory of Bioelectronics and Jiangsu Key Laboratory of Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Yuehui Yuan
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
| | - Jin Li
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
| | - Huaxu Ling
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
| | - Yanjie Chen
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
| | - Ping Yang
- School of Materials Science and Engineering, Nanjing Institute of Technology, Nanjing, 211167, China.
| | - Jianqing Li
- State Key Laboratory of Bioelectronics and Jiangsu Key Laboratory of Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
- School of Instrument Science and Engineering, Southeast University, Nanjing, 210096, China.
| | - Benhui Hu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China.
| |
Collapse
|
31
|
Das KK, Basu B, Maiti P, Dubey AK. Piezoelectric nanogenerators for self-powered wearable and implantable bioelectronic devices. Acta Biomater 2023; 171:85-113. [PMID: 37673230 DOI: 10.1016/j.actbio.2023.08.057] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/05/2023] [Accepted: 08/29/2023] [Indexed: 09/08/2023]
Abstract
One of the recent innovations in the field of personalized healthcare is the piezoelectric nanogenerators (PENGs) for various clinical applications, including self-powered sensors, drug delivery, tissue regeneration etc. Such innovations are perceived to potentially address some of the unmet clinical needs, e.g., limited life-span of implantable biomedical devices (e.g., pacemaker) and replacement related complications. To this end, the generation of green energy from biomechanical sources for wearable and implantable bioelectronic devices gained considerable attention in the scientific community. In this perspective, this article provides a comprehensive state-of-the-art review on the recent developments in the processing, applications and associated concerns of piezoelectric materials (synthetic/biological) for personalized healthcare applications. In particular, this review briefly discusses the concepts of piezoelectric energy harvesting, piezoelectric materials (ceramics, polymers, nature-inspired), and the various applications of piezoelectric nanogenerators, such as, self-powered sensors, self-powered pacemakers, deep brain stimulators etc. Important distinction has been made in terms of the potential clinical applications of PENGs, either as wearable or implantable bioelectronic devices. While discussing the potential applications as implantable devices, the biocompatibility of the several hybrid devices using large animal models is summarized. This review closes with the futuristic vision of integrating data science approaches in developmental pipeline of PENGs as well as clinical translation of the next generation PENGs. STATEMENT OF SIGNIFICANCE: Piezoelectric nanogenerators (PENGs) hold great promise for transforming personalized healthcare through self-powered sensors, drug delivery systems, and tissue regeneration. The limited battery life of implantable devices like pacemakers presents a significant challenge, leading to complications from repititive surgeries. To address such a critical issue, researchers are focusing on generating green energy from biomechanical sources to power wearable and implantable bioelectronic devices. This comprehensive review critically examines the latest advancements in synthetic and nature-inspired piezoelectric materials for PENGs in personalized healthcare. Moreover, it discusses the potential of piezoelectric materials and data science approaches to enhance the efficiency and reliability of personalized healthcare devices for clinical applications.
Collapse
Affiliation(s)
- Kuntal Kumar Das
- Department of Ceramic Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India
| | - Bikramjit Basu
- Materials Research Center, Indian Institute of Science, Bengaluru 560012, India
| | - Pralay Maiti
- SMST, Indian Institute of Technology (BHU), Varanasi 221005, India
| | - Ashutosh Kumar Dubey
- Department of Ceramic Engineering, Indian Institute of Technology (BHU), Varanasi 221005, India.
| |
Collapse
|
32
|
Qian Y, Zhou P, Wang Y, Zheng Y, Luo Z, Chen L. A PEDOT:PSS/MXene-based actuator with self-powered sensing function by incorporating a photo-thermoelectric generator. RSC Adv 2023; 13:32722-32733. [PMID: 38022765 PMCID: PMC10630741 DOI: 10.1039/d3ra06290b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 10/23/2023] [Indexed: 12/01/2023] Open
Abstract
Actuators with sensing functions are becoming increasingly important in the field of soft robotics. However, most of the actuators are lack of self-powered sensing ability, which limits their applications. Here, we report a light-driven actuator with self-powered sensing function, which is designed to incorporate a photo-thermoelectric generator into the actuator based on poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)/MXene composite and polyimide. The actuator shows a large bending curvature of 1.8 cm-1 under near-infrared light (800 mW cm-2) irradiation for 10 s, which is attribute to photothermal expansion mismatch between PEDOT:PSS/MXene composite and polyimide. Simultaneously, the actuator shows enhanced thermoelectric properties with Seebeck coefficient of 35.7 μV K-1, which are mainly attributed to a combination of energy filtering effects between the PEDOT:PSS and MXene interfaces as well as the synergistic effect of its charge carrier migration. The output voltage of the actuator changes in accordance with the bending curvature, so as to achieve the self-powered sensing function and monitor the operating state of the actuator. Moreover, a bionic flower is fabricated, which not only simulates the blooming and closing of the flower, but also perceives the real-time actuation status through the output voltage signal. Finally, a smart Braille system is elaborately designed, which can not only simulate Braille characters for tactile recognition of the blind people, but also automatically output the voltage signal of Braille for self-powered sensing, enabling multi-channel output and conversion of light energy. This research proposes a new idea for exploring multifunctional actuators, integrated devices and self-powered soft robots.
Collapse
Affiliation(s)
- Yongqiang Qian
- Fujian Provincial Key Laboratory of Quantum Manipulation and New Energy Materials, College of Physics and Energy, Fujian Normal University Fuzhou 350117 China
- Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering Fuzhou 350117 China
- Fujian Provincial Engineering Technology Research Center of Solar Energy Conversion and Energy Storage Fuzhou 350117 China
| | - Peidi Zhou
- Institute of Smart Marine and Engineering, Fujian University of Technology Fuzhou 350118 China
| | - Yi Wang
- Fujian Provincial Key Laboratory of Quantum Manipulation and New Energy Materials, College of Physics and Energy, Fujian Normal University Fuzhou 350117 China
- Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering Fuzhou 350117 China
- Fujian Provincial Engineering Technology Research Center of Solar Energy Conversion and Energy Storage Fuzhou 350117 China
| | - Ying Zheng
- Department of Obstetrics, Fuzhou Second Hospital Fuzhou 350007 China
| | - Zhiling Luo
- Fujian Provincial Key Laboratory of Quantum Manipulation and New Energy Materials, College of Physics and Energy, Fujian Normal University Fuzhou 350117 China
- Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering Fuzhou 350117 China
- Fujian Provincial Engineering Technology Research Center of Solar Energy Conversion and Energy Storage Fuzhou 350117 China
| | - Luzhuo Chen
- Fujian Provincial Key Laboratory of Quantum Manipulation and New Energy Materials, College of Physics and Energy, Fujian Normal University Fuzhou 350117 China
- Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering Fuzhou 350117 China
- Fujian Provincial Engineering Technology Research Center of Solar Energy Conversion and Energy Storage Fuzhou 350117 China
| |
Collapse
|
33
|
Lin J, Chen Z, Zhuang Q, Chen S, Zhu C, Wei Y, Wang S, Wu D. Temperature-Immune, Wide-Range Flexible Robust Pressure Sensors for Harsh Environments. ACS APPLIED MATERIALS & INTERFACES 2023; 15:49642-49652. [PMID: 37831933 DOI: 10.1021/acsami.3c10975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2023]
Abstract
Flexible pressure sensors possess vast potential for various applications such as new energy batteries, aerospace engines, and rescue robots owing to their exceptional flexibility and adaptability. However, the existing sensors face significant challenges in maintaining long-term reliability and environmental resilience when operating in harsh environments with variable temperatures and high pressures (∼MPa), mainly due to possible mechanical mismatch and structural instability. Here, we propose a composite scheme for a flexible piezoresistive pressure sensor to improve its robustness by utilizing material design of near-zero temperature coefficient of resistance (TCR), radial gradient pressure-dividing microstructure, and flexible interface bonding process. The sensing layer comprising multiwalled carbon nanotubes (MWCNTs), graphite (GP), and thermoplastic polyurethane (TPU) was optimized to achieve a near-zero temperature coefficient of resistance over a temperature range of 25-70 °C, while the radial gradient microstructure layout based on pressure division increases the range of pressure up to 2 MPa. Furthermore, a flexible interface bonding process introduces a self-soluble transition layer by direct-writing TPU bonding solution at the bonding interface, which enables the sensor to achieve signal fluctuations as low as 0.6% and a high interface strength of up to 1200 kPa. Moreover, it has been further validated for its capability of monitoring the physiological signals of athletes as well as the long-term reliable environmental resilience of the expansion pressure of the power cell. This work demonstrates that the proposed scheme sheds new light on the design of robust pressure sensors for harsh environments.
Collapse
Affiliation(s)
- Jiawei Lin
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361101, China
| | - Zhiwen Chen
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361101, China
| | - Qibin Zhuang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361101, China
| | - Songyue Chen
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361101, China
| | - Cuicui Zhu
- Fujian Science & Technology Innovation Laboratory for Energy Devices of China (21C LAB), Ningde 352100, China
| | - Yimin Wei
- Fujian Science & Technology Innovation Laboratory for Energy Devices of China (21C LAB), Ningde 352100, China
| | - Shaofei Wang
- Fujian Science & Technology Innovation Laboratory for Energy Devices of China (21C LAB), Ningde 352100, China
| | - Dezhi Wu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361101, China
| |
Collapse
|
34
|
Kang M, Lee DM, Hyun I, Rubab N, Kim SH, Kim SW. Advances in Bioresorbable Triboelectric Nanogenerators. Chem Rev 2023; 123:11559-11618. [PMID: 37756249 PMCID: PMC10571046 DOI: 10.1021/acs.chemrev.3c00301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Indexed: 09/29/2023]
Abstract
With the growing demand for next-generation health care, the integration of electronic components into implantable medical devices (IMDs) has become a vital factor in achieving sophisticated healthcare functionalities such as electrophysiological monitoring and electroceuticals worldwide. However, these devices confront technological challenges concerning a noninvasive power supply and biosafe device removal. Addressing these challenges is crucial to ensure continuous operation and patient comfort and minimize the physical and economic burden on the patient and the healthcare system. This Review highlights the promising capabilities of bioresorbable triboelectric nanogenerators (B-TENGs) as temporary self-clearing power sources and self-powered IMDs. First, we present an overview of and progress in bioresorbable triboelectric energy harvesting devices, focusing on their working principles, materials development, and biodegradation mechanisms. Next, we examine the current state of on-demand transient implants and their biomedical applications. Finally, we address the current challenges and future perspectives of B-TENGs, aimed at expanding their technological scope and developing innovative solutions. This Review discusses advancements in materials science, chemistry, and microfabrication that can advance the scope of energy solutions available for IMDs. These innovations can potentially change the current health paradigm, contribute to enhanced longevity, and reshape the healthcare landscape soon.
Collapse
Affiliation(s)
- Minki Kang
- School
of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon 16419, Republic
of Korea
| | - Dong-Min Lee
- School
of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon 16419, Republic
of Korea
| | - Inah Hyun
- Department
of Materials Science and Engineering, Center for Human-oriented Triboelectric
Energy Harvesting, Yonsei University, Seoul 03722, Republic of Korea
| | - Najaf Rubab
- Department
of Materials Science and Engineering, Gachon
University, Seongnam 13120, Republic
of Korea
| | - So-Hee Kim
- Department
of Materials Science and Engineering, Center for Human-oriented Triboelectric
Energy Harvesting, Yonsei University, Seoul 03722, Republic of Korea
| | - Sang-Woo Kim
- Department
of Materials Science and Engineering, Center for Human-oriented Triboelectric
Energy Harvesting, Yonsei University, Seoul 03722, Republic of Korea
| |
Collapse
|
35
|
Huang S, Gao Y, Hu Y, Shen F, Jin Z, Cho Y. Recent development of piezoelectric biosensors for physiological signal detection and machine learning assisted cardiovascular disease diagnosis. RSC Adv 2023; 13:29174-29194. [PMID: 37818271 PMCID: PMC10561672 DOI: 10.1039/d3ra05932d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 09/21/2023] [Indexed: 10/12/2023] Open
Abstract
As cardiovascular disease stands as a global primary cause of mortality, there has been an urgent need for continuous and real-time heart monitoring to effectively identify irregular heart rhythms and to offer timely patient alerts. However, conventional cardiac monitoring systems encounter challenges due to inflexible interfaces and discomfort during prolonged monitoring. In this review article, we address these issues by emphasizing the recent development of the flexible, wearable, and comfortable piezoelectric passive sensor assisted by machine learning technology for diagnosis. This innovative device not only harmonizes with the dynamic mechanical properties of human skin but also facilitates continuous and real-time collection of physiological signals. Addressing identified challenges and constraints, this review provides insights into recent advances in piezoelectric cardiac sensors, from devices to circuit systems. Furthermore, this review delves into the integration of machine learning technologies, showcasing their pivotal role in facilitating continuous and real-time assessment of cardiac status. The synergistic combination of flexible piezoelectric sensor design and machine learning holds substantial potential in automating the detection of cardiac irregularities with minimal human intervention. This transformative approach has the power to revolutionize patient care paradigms.
Collapse
Affiliation(s)
- Shunyao Huang
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yujia Gao
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yian Hu
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Fengyi Shen
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Zhangsiyuan Jin
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| | - Yuljae Cho
- University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University Minhang District Shanghai 200240 China
| |
Collapse
|
36
|
Han L, Liang W, Xie Q, Zhao J, Dong Y, Wang X, Lin L. Health Monitoring via Heart, Breath, and Korotkoff Sounds by Wearable Piezoelectret Patches. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2301180. [PMID: 37607132 PMCID: PMC10558643 DOI: 10.1002/advs.202301180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 06/21/2023] [Indexed: 08/24/2023]
Abstract
Real-time monitoring of vital sounds from cardiovascular and respiratory systems via wearable devices together with modern data analysis schemes have the potential to reveal a variety of health conditions. Here, a flexible piezoelectret sensing system is developed to examine audio physiological signals in an unobtrusive manner, including heart, Korotkoff, and breath sounds. A customized electromagnetic shielding structure is designed for precision and high-fidelity measurements and several unique physiological sound patterns related to clinical applications are collected and analyzed. At the left chest location for the heart sounds, the S1 and S2 segments related to cardiac systole and diastole conditions, respectively, are successfully extracted and analyzed with good consistency from those of a commercial medical device. At the upper arm location, recorded Korotkoff sounds are used to characterize the systolic and diastolic blood pressure without a doctor or prior calibration. An Omron blood pressure monitor is used to validate these results. The breath sound detections from the lung/ trachea region are achieved a signal-to-noise ration comparable to those of a medical recorder, BIOPAC, with pattern classification capabilities for the diagnosis of viable respiratory diseases. Finally, a 6×6 sensor array is used to record heart sounds at different locations of the chest area simultaneously, including the Aortic, Pulmonic, Erb's point, Tricuspid, and Mitral regions in the form of mixed data resulting from the physiological activities of four heart valves. These signals are then separated by the independent component analysis algorithm and individual heart sound components from specific heart valves can reveal their instantaneous behaviors for the accurate diagnosis of heart diseases. The combination of these demonstrations illustrate a new class of wearable healthcare detection system for potentially advanced diagnostic schemes.
Collapse
Affiliation(s)
- Liuyang Han
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - Weijin Liang
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - Qisen Xie
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - JingJing Zhao
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - Ying Dong
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - Xiaohao Wang
- Tsinghua Shenzhen International Graduate SchoolTsinghua University518055ShenzhenChina
| | - Liwei Lin
- Department of mechanical engineeringUniversity of CaliforniaBerkeleyBerkeleyUSA
| |
Collapse
|
37
|
Zhang T, Liu N, Xu J, Liu Z, Zhou Y, Yang Y, Li S, Huang Y, Jiang S. Flexible electronics for cardiovascular healthcare monitoring. Innovation (N Y) 2023; 4:100485. [PMID: 37609559 PMCID: PMC10440597 DOI: 10.1016/j.xinn.2023.100485] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Accepted: 07/23/2023] [Indexed: 08/24/2023] Open
Abstract
Cardiovascular diseases (CVDs) are one of the most urgent threats to humans worldwide, which are responsible for almost one-third of global mortality. Over the last decade, research on flexible electronics for monitoring and treatment of CVDs has attracted tremendous attention. In contrast to conventional medical instruments in hospitals that are usually bulky, hard to move, monofunctional, and time-consuming, flexible electronics are capable of continuous, noninvasive, real-time, and portable monitoring. Notable progress has been made in this emerging field, and thus a number of significant achievements and concomitant research prospects deserve attention for practical implementation. Here, we comprehensively review the latest progress of flexible electronics for CVDs, focusing on new functions provided by flexible electronics. First, the characteristics of CVDs and flexible electronics and the foundation of their combination are briefly reviewed. Then, four representative applications of flexible electronics for CVDs are elaborated: blood pressure (BP) monitoring, electrocardiogram (ECG) monitoring, echocardiogram monitoring, and direct epicardium monitoring. Their operational principles, progress, merits and demerits, and future efforts are discussed. Finally, the remaining challenges and opportunities for flexible electronics for cardiovascular healthcare are outlined.
Collapse
Affiliation(s)
- Tianqi Zhang
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| | - Ning Liu
- Department of Gastrointestinal Surgery, Hainan General Hospital, Hainan Affiliated Hospital of Hainan Medical University, Haikou 570311, China
| | - Jing Xu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Zeye Liu
- Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100037, China
| | - Yunlei Zhou
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| | - Yicheng Yang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Shoujun Li
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Pediatric Cardiac Surgery Center, Fuwai Hospital, Chinese Academy of Medical Sciences, and Peking Union Medical College, Beijing 100037, China
| | - Yuan Huang
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Pediatric Cardiac Surgery Center, Fuwai Hospital, Chinese Academy of Medical Sciences, and Peking Union Medical College, Beijing 100037, China
| | - Shan Jiang
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China
| |
Collapse
|
38
|
Min WK, Won C, Kim DH, Lee S, Chung J, Cho S, Lee T, Kim HJ. Strain-Driven Negative Resistance Switching of Conductive Fibers with Adjustable Sensitivity for Wearable Healthcare Monitoring Systems with Near-Zero Standby Power. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2303556. [PMID: 37177845 DOI: 10.1002/adma.202303556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Indexed: 05/15/2023]
Abstract
Recently, one of the primary concerns in e-textile-based healthcare monitoring systems for chronic illness patients has been reducing wasted power consumption, as the system should be always-on to capture diverse biochemical and physiological characteristics. However, the general conductive fibers, a major component of the existing wearable monitoring systems, have a positive gauge-factor (GF) that increases electrical resistance when stretched, so that the systems have no choice but to consume power continuously. Herein, a twisted conductive-fiber-based negatively responsive switch-type (NRS) strain-sensor with an extremely high negative GF (resistance change ratio ≈ 3.9 × 108 ) that can significantly increase its conductivity from insulating to conducting properties is developed. To this end, a precision cracking technology is devised, which could induce a difference in the Young's modulus of the encapsulated layer on the fiber through selective ultraviolet-irradiation treatment. Owing to this technology, the NRS strain-sensors can allow for effective regulation of the mutual contact resistance under tensile strain while maintaining superior durability for over 5000 stretching cycles. For further practical demonstrations, three healthcare monitoring systems (E-fitness pants, smart-masks, and posture correction T-shirts) with near-zero standby power are also developed, which opens up advancements in electronic textiles by expanding the utilization range of fiber strain-sensors.
Collapse
Affiliation(s)
- Won Kyung Min
- Electronic Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Chihyeong Won
- Nanobio Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Dong Hyun Kim
- Electronic Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sanghyeon Lee
- KIURI Institute, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jusung Chung
- BIT Micro Fab Research Center, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sungjoon Cho
- Nanobio Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Taeyoon Lee
- Nanobio Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Hyun Jae Kim
- Electronic Device Laboratory, School of Electrical and Electronic Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| |
Collapse
|
39
|
Zhu B, Xu Z, Liu X, Wang Z, Zhang Y, Chen Q, Teh KS, Zheng J, Du X, Wu D. High-Linearity Flexible Pressure Sensor Based on the Gaussian-Curve-Shaped Microstructure for Human Physiological Signal Monitoring. ACS Sens 2023; 8:3127-3135. [PMID: 37471516 DOI: 10.1021/acssensors.3c00818] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
Flexible pressure sensors with high-performance show broad application prospects in health monitoring, wearable electronic devices, intelligent robot sensing, and other fields. Although flexible pressure sensors have made significant progress in sensitivity and detection range, most of them still exhibit strong nonlinearity, which leads to significant troubles in signal acquisition and thus limits their popularity in practical applications. It remains a serious challenge for the flexible pressure sensor to achieve high linearity while maintaining high sensitivity. Herein, a doped sensing membrane with a uniformly distributed Gaussian-curve-shaped micropattern array was developed using the micro-electromechanical systems (MEMS) process, and a flexible sensor structure with the doped film as the core was designed and constructed. The prototype sensor has a high sensitivity of 1.77 kPa-1 and a linearity of 0.99 in the full detection range of 20 Pa to 30 kPa. In addition, its excellent performance also includes fast response/recovery times (∼25/50 ms) and long-term endurance (>10,000 cycles at 15 kPa). The prototype sensor has been successfully demonstrated in human pulse monitoring, speech recognition, and gesture recognition. The 2 × 6 sensor array can detect the spatial pressure distribution. Thus, such a microstructure shape design will open a new way to fabricate a high-linearity pressure sensor for potential applications in health monitoring, human-machine interaction, etc.
Collapse
Affiliation(s)
- Bin Zhu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Zhenjin Xu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Xin Liu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Zhongbao Wang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Yang Zhang
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Qinnan Chen
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Kwok Siong Teh
- School of Engineering, San Francisco State University, San Francisco, California 94132, United States
| | - Jianyi Zheng
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| | - Xiaohui Du
- Sensor and network control center, Instrumentation Technology and Economy Institute, Beijing 100055, China
| | - Dezhi Wu
- Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen 361005, China
| |
Collapse
|
40
|
Song Y, Jo H, Song JH. Multiresponsive 3D Structured PVDF Cube Switches for Security Systems Using Piezoelectric Anisotropy. ACS APPLIED MATERIALS & INTERFACES 2023; 15:38550-38561. [PMID: 37535811 DOI: 10.1021/acsami.3c03377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Advancements in flexible electronics using piezoelectric materials have paved the way for numerous applications. In this study, we suggest a three-dimensional (3D) structured poly(vinylidene fluoride) (PVDF) film cube switch to maximize piezoelectric anisotropy and flexibility. Unlike piezoelectric material-based flexible electronics, PVDF cube switches have a simple design and easy fabrication process. Each side of the cube switch demonstrates independent voltage signals with pressing displacements and corresponding directions. With cutting angle variations and planar figure designs, derived cube switches respond with various combinations of voltage waveforms. PVDF switches can endure more than 1000 cycles of 70% vertical strain in terms of both electrical responses and mechanical operations. As an application, we establish a security system with multiresponsibility of a cube switch. This security system can protect users from potential threats owing to its multiresponsibility and user-dependent operability.
Collapse
Affiliation(s)
- Yujun Song
- Department of Mechanical Engineering, Dankook University, Yongin 16890, South Korea
| | - Hyeongjin Jo
- Department of Mechanical Engineering, Dankook University, Yongin 16890, South Korea
| | - Ji-Hyeon Song
- Department of Mechanical Engineering, Dankook University, Yongin 16890, South Korea
| |
Collapse
|
41
|
Ran P, Li M, Zhang K, Sun D, Lai Y, Liu W, Zhong Y, Li Z. Development and Evaluation of a Flexible PVDF-Based Balloon Sensor for Detecting Mechanical Forces at Key Esophageal Nodes in Esophageal Motility Disorders. BIOSENSORS 2023; 13:791. [PMID: 37622877 PMCID: PMC10452430 DOI: 10.3390/bios13080791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/01/2023] [Accepted: 08/02/2023] [Indexed: 08/26/2023]
Abstract
Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively devised an infusible flexible balloon catheter, equipped with a quartet of PVDF piezoelectric sensors. This design, working in concert with a bespoke local key-node analytical algorithm and a sensor array state analysis model, seeks to shed new light on the dynamic mechanical characteristics at pivotal esophageal locales. To further this endeavor, we pioneered a singular closed balloon system and a complementary signal acquisition and processing system that employs a homogeneously distributed PVDF piezoelectric sensor array for the real-time monitoring of dynamic mechanical nuances in the esophageal segment. An advanced analytical model was established to scrutinize the coupled physical fields under varying degrees of balloon inflation, thereby facilitating a thorough dynamic stress examination of local esophageal nodes. Our rigorous execution of static, dynamic, and simulated swallowing experiments robustly substantiated the viability of our design, the logical coherence of our esophageal key-point stress analytical algorithm, and the potential clinical utility of a flexible esophageal key-node stress detection balloon probe outfitted with a PVDF array. This study offers a fresh lens through which esophageal motility testing can be viewed and improved upon.
Collapse
Affiliation(s)
- Peng Ran
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing 400065, China;
| | - Minchuan Li
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing 400065, China;
| | - Kunlin Zhang
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
| | - Daming Sun
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing 400065, China;
| | - Yingbing Lai
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
| | - Wei Liu
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
| | - Ying Zhong
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing 400065, China; (P.R.); (K.Z.); (D.S.); (W.L.); (Y.Z.)
| | - Zhangyong Li
- Chongqing Engineering Research Center of Medical Electronics and Information Technology, Chongqing 400065, China;
- School of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, China
| |
Collapse
|
42
|
Yu H, Li H, Sun X, Pan L. Biomimetic Flexible Sensors and Their Applications in Human Health Detection. Biomimetics (Basel) 2023; 8:293. [PMID: 37504181 PMCID: PMC10807369 DOI: 10.3390/biomimetics8030293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 06/27/2023] [Accepted: 06/27/2023] [Indexed: 07/29/2023] Open
Abstract
Bionic flexible sensors are a new type of biosensor with high sensitivity, selectivity, stability, and reliability to achieve detection in complex natural and physiological environments. They provide efficient, energy-saving and convenient applications in medical monitoring and diagnosis, environmental monitoring, and detection and identification. Combining sensor devices with flexible substrates to imitate flexible structures in living organisms, thus enabling the detection of various physiological signals, has become a hot topic of interest. In the field of human health detection, the application of bionic flexible sensors is flourishing and will evolve into patient-centric diagnosis and treatment in the future of healthcare. In this review, we provide an up-to-date overview of bionic flexible devices for human health detection applications and a comprehensive summary of the research progress and potential of flexible sensors. First, we evaluate the working mechanisms of different classes of bionic flexible sensors, describing the selection and fabrication of bionic flexible materials and their excellent electrochemical properties; then, we introduce some interesting applications for monitoring physical, electrophysiological, chemical, and biological signals according to more segmented health fields (e.g., medical diagnosis, rehabilitation assistance, and sports monitoring). We conclude with a summary of the advantages of current results and the challenges and possible future developments.
Collapse
Affiliation(s)
| | | | - Xidi Sun
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| | - Lijia Pan
- Collaborative Innovation Center of Advanced Microstructures, School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
43
|
Tao LQ, Gao C, Wang G, Sun H, Guo LY, Ren TL. High sensitivity graphene based health sensor with self-warning function. COMPOSITES SCIENCE AND TECHNOLOGY 2023; 241:110123. [PMID: 38620137 PMCID: PMC10300061 DOI: 10.1016/j.compscitech.2023.110123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/01/2023] [Accepted: 06/16/2023] [Indexed: 04/17/2024]
Abstract
In order to reduce the damage to people's health from diseases that attack the respiratory system such as COVID-19, asthma, and pneumonia, it is desired that patients' breathing can be monitored and alerted in real-time. The emergence of wearable health detection sensing devices has provided a relatively good response to this problem. However, there are still problems such as complex structure and poor performance. This paper introduces a laser-induced graphene (LIG) device that is attached to PDMS. The LIG is produced by laser irradiation of Nomex and subsequently transferred and attached to the PDMS. After being tested, it has demonstrated high sensitivity, stable tensile performance, good acoustic performance, excellent thermal stability, and other favorable properties. Notably, its gauge factor (GF) value can reach 721.67, which is quite impressive. Additionally, it is capable of emitting an alarm sound with an SPL close to 60 dB when receiving signals within the range of 5-20 kHz. The device realizes mechanical sensing and acoustic functions in one chip, and has a high application value in applications that need to combine sensing and early warning.
Collapse
Affiliation(s)
- Lu-Qi Tao
- Beijing Engineering Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing, 100083, China
| | - Chenwei Gao
- National Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Guanya Wang
- National Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Hao Sun
- National Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Liang-Yan Guo
- National Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing, 400044, China
| | - Tian-Ling Ren
- Institute of Microelectronics and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing, 100084, China
| |
Collapse
|
44
|
Hu J, Dun G, Geng X, Chen J, Wu X, Ren TL. Recent progress in flexible micro-pressure sensors for wearable health monitoring. NANOSCALE ADVANCES 2023; 5:3131-3145. [PMID: 37325539 PMCID: PMC10262959 DOI: 10.1039/d2na00866a] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 02/16/2023] [Indexed: 06/17/2023]
Abstract
In recent years, flexible micro-pressure sensors have been used widely in wearable health monitoring applications due to their excellent flexibility, stretchability, non-invasiveness, comfort wearing and real-time detection. According to the working mechanism of the flexible micro-pressure sensor, it can be classified as piezoresistive, piezoelectric, capacitive and triboelectric types. Herein, an overview of flexible micro-pressure sensors for wearable health monitoring is presented. The physiological signaling and body motions contain a lot of health status information. Thus, this review focuses on the applications of flexible micro-pressure sensors in these fields. Additionally, the contents of sensing mechanism, sensing materials and performance of flexible micro-pressure sensors are introduced in detail. Finally, we predict the future research directions of the flexible micro-pressure sensors, and discuss the challenges in practical applications.
Collapse
Affiliation(s)
- Jianguo Hu
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| | - Guanhua Dun
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| | - Xiangshun Geng
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| | - Jing Chen
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| | - Xiaoming Wu
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| | - Tian-Ling Ren
- School of Integrated Circuits, Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University Beijing 100084 China
| |
Collapse
|
45
|
Zhang D, Yang Y, Rao WF. Parameter Optimization for Printing Barium Titanate Piezoelectric Ceramics through Digital Light Processing. MICROMACHINES 2023; 14:1146. [PMID: 37374731 DOI: 10.3390/mi14061146] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 05/24/2023] [Accepted: 05/26/2023] [Indexed: 06/29/2023]
Abstract
Digital light processing (DLP) technology has emerged as a promising 3D printing technology with the potential for the efficient manufacturing of complex ceramic devices. However, the quality of printed products is highly dependent on various process parameters, including slurry formulation, heat treatment process, and poling process. This paper optimizes the printing process with respect to these key parameters, such as using a ceramic slurry with 75 wt% powder content. The employed degreasing heating rate is 4 °C/min, the carbon-removing heating rate is 4 °C/min, and the sintering heating rate is 2 °C/min for heat treatment of the printed green body. The resulting parts are polarized using a poling field of 10 kV/cm, a poling time of 50 min, and a poling temperature of 60 °C, which yields a piezoelectric device with a high piezoelectric constant of 211 pC/N. To demonstrate the practical application of the device, its use as a force sensor and magnetic sensor is validated.
Collapse
Affiliation(s)
- Dongcai Zhang
- Faculty of Mechanical Engineering, Shandong Institute of Mechanical Design and Research, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
| | - Yaodong Yang
- Faculty of Mechanical Engineering, Shandong Institute of Mechanical Design and Research, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
| | - Wei-Feng Rao
- Faculty of Mechanical Engineering, Shandong Institute of Mechanical Design and Research, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
| |
Collapse
|
46
|
Zhao L, Liang C, Huang Y, Zhou G, Xiao Y, Ji N, Zhang YT, Zhao N. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. NPJ Digit Med 2023; 6:93. [PMID: 37217650 DOI: 10.1038/s41746-023-00835-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 05/05/2023] [Indexed: 05/24/2023] Open
Abstract
Cardiovascular diseases (CVDs) are a leading cause of death worldwide. For early diagnosis, intervention and management of CVDs, it is highly desirable to frequently monitor blood pressure (BP), a vital sign closely related to CVDs, during people's daily life, including sleep time. Towards this end, wearable and cuffless BP extraction methods have been extensively researched in recent years as part of the mobile healthcare initiative. This review focuses on the enabling technologies for wearable and cuffless BP monitoring platforms, covering both the emerging flexible sensor designs and BP extraction algorithms. Based on the signal type, the sensing devices are classified into electrical, optical, and mechanical sensors, and the state-of-the-art material choices, fabrication methods, and performances of each type of sensor are briefly reviewed. In the model part of the review, contemporary algorithmic BP estimation methods for beat-to-beat BP measurements and continuous BP waveform extraction are introduced. Mainstream approaches, such as pulse transit time-based analytical models and machine learning methods, are compared in terms of their input modalities, features, implementation algorithms, and performances. The review sheds light on the interdisciplinary research opportunities to combine the latest innovations in the sensor and signal processing research fields to achieve a new generation of cuffless BP measurement devices with improved wearability, reliability, and accuracy.
Collapse
Affiliation(s)
- Lei Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Cunman Liang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yan Huang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
| | - Guodong Zhou
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
| | - Yiqun Xiao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Nan Ji
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Yuan-Ting Zhang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Ni Zhao
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, China.
- Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.
| |
Collapse
|
47
|
Liu S, Liao J, Huang X, Zhang Z, Wang W, Wang X, Shan Y, Li P, Hong Y, Peng Z, Li X, Khoo BL, Ho JC, Yang Z. Green Fabrication of Freestanding Piezoceramic Films for Energy Harvesting and Virus Detection. NANO-MICRO LETTERS 2023; 15:131. [PMID: 37209322 PMCID: PMC10199448 DOI: 10.1007/s40820-023-01105-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 04/17/2023] [Indexed: 05/22/2023]
Abstract
Most electronics such as sensors, actuators and energy harvesters need piezoceramic films to interconvert mechanical and electrical energy. Transferring the ceramic films from their growth substrates for assembling electronic devices commonly requires chemical or physical etching, which comes at the sacrifice of the substrate materials, film cracks, and environmental contamination. Here, we introduce a van der Waals stripping method to fabricate large-area and freestanding piezoceramic thin films in a simple, green, and cost-effective manner. The introduction of the quasi van der Waals epitaxial platinum layer enables the capillary force of water to drive the separation process of the film and substrate interface. The fabricated lead-free film, [Formula: see text] (BCZT), shows a high piezoelectric coefficient d33 = 209 ± 10 pm V-1 and outstanding flexibility of maximum strain 2%. The freestanding feature enables a wide application scenario, including micro energy harvesting, and covid-19 spike protein detection. We further conduct a life cycle analysis and quantify the low energy consumption and low pollution of the water-based stripping film method.
Collapse
Affiliation(s)
- Shiyuan Liu
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Junchen Liao
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Xin Huang
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Zhuomin Zhang
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Weijun Wang
- Department of Materials Science and Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Xuyang Wang
- Guangdong Provincial Key Laboratory of Functional Oxide Materials and Devices, Southern University of Science and Technology, Shenzhen, 518055, Guangdong, People's Republic of China
| | - Yao Shan
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Pengyu Li
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Ying Hong
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Zehua Peng
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Xuemu Li
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Bee Luan Khoo
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
| | - Johnny C Ho
- Department of Materials Science and Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC
- Department of Materials Science and Engineering, State Key Laboratory of Terahertz and Millimeter Waves, City University of Hong Kong, Kowloon, Hong Kong SAR PRC
| | - Zhengbao Yang
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, People's Republic of China.
- Department of Mechanical Engineering, City University of Hong Kong, Hong Kong, Hong Kong SAR PRC.
| |
Collapse
|
48
|
Zu L, Wen J, Wang S, Zhang M, Sun W, Chen B, Wang ZL. Multiangle, self-powered sensor array for monitoring head impacts. SCIENCE ADVANCES 2023; 9:eadg5152. [PMID: 37196075 DOI: 10.1126/sciadv.adg5152] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 04/14/2023] [Indexed: 05/19/2023]
Abstract
Mild concussions occur frequently and may come with long-term cognitive, affective, and physical sequelae. However, the diagnosis of mild concussions lacks objective assessment and portable monitoring techniques. Here, we propose a multiangle self-powered sensor array for real-time monitoring of head impact to further assist in clinical analysis and prevention of mild concussions. The array uses triboelectric nanogenerator technology, which converts impact force from multiple directions into electrical signals. With an average sensitivity of 0.214 volts per kilopascal, a response time of 30 milliseconds, and a minimum resolution of 1.415 kilopascals, the sensors exhibit excellent sensing capability over a range of 0 to 200 kilopascals. Furthermore, the array enables reconstructed head impact mapping and injury grade assessment via a prewarning system. By gathering standardized data, we expect to build a big data platform that will permit in-depth research of the direct and indirect effects between head impacts and mild concussions in the future.
Collapse
Affiliation(s)
- Lulu Zu
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Jing Wen
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Shengbo Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Ming Zhang
- Senior Department of Cardiology, The First Medical Center of PLA General Hospital, Beijing 100853, P. R. China
| | - Wuliang Sun
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
| | - Baodong Chen
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Zhong Lin Wang
- Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, P. R. China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, P. R. China
- Georgia Institute of Technology, Atlanta, GA 30332-0245, USA
| |
Collapse
|
49
|
Ji T, Gong W, Zhou J, Jing Y, Xing R, Zhu B, Li K, Hou C, Zhang Q, Li Y, Wang H. Scalable multi-dimensional topological deformation actuators for active object identification. MATERIALS HORIZONS 2023; 10:1726-1736. [PMID: 36891764 DOI: 10.1039/d2mh01567f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Rarely are bionic robots capable of rapid multi-dimensional deformation and object identification in the same way as animals and plants. This study proposes a topological deformation actuator for bionic robots based on pre-expanded polyethylene and large flake MXene, inspired by the octopus predation behavior. This unusual, large-area topological deformation actuator (easily reaching 800 cm2 but is not constrained to this size) prepared by large-scale blow molding and continuous scrape coating exhibits different distribution states of molecular chains at low and high temperatures, causing the actuator's deformation direction to change axially. With its multi-dimensional topological deformation and self-powered active object identification capabilities, the actuator can capture objects like an octopus. The contact electrification effect assists the actuator to identify the type and size of the target object during this multi-dimensional topological deformation that is controllable and designable. This work demonstrates the direct conversion of light energy into contact electrical signals, introducing a new route for the practicality and scaling of bionic robots.
Collapse
Affiliation(s)
- Tianyi Ji
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
- Engineering Research Center of Advanced Glasses Manufacturing Technology, Ministry of Education, Donghua University, Shanghai 201620, P. R. China.
| | - Wei Gong
- College of Light-Textile Engineering and Art, Anhui Agricultural University, Hefei 230036, P. R. China.
- Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583, Singapore
| | - Jie Zhou
- School of Electronic Information and Electrical Engineering, Chengdu University, Chengdu 610100, China
| | - Yangmin Jing
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
| | - Ruizhe Xing
- School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an 710072, P. R. China
| | - Bingjie Zhu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
| | - Kerui Li
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
| | - Chengyi Hou
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
| | - Qinghong Zhang
- Engineering Research Center of Advanced Glasses Manufacturing Technology, Ministry of Education, Donghua University, Shanghai 201620, P. R. China.
| | - Yaogang Li
- Engineering Research Center of Advanced Glasses Manufacturing Technology, Ministry of Education, Donghua University, Shanghai 201620, P. R. China.
| | - Hongzhi Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, P. R. China.
| |
Collapse
|
50
|
Chefchaouni Moussaoui S, Cisneros-Limón R, Kaminaga H, Benallegue M, Nobeshima T, Kanazawa S, Kanehiro F. Spatial Calibration of Humanoid Robot Flexible Tactile Skin for Human-Robot Interaction. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094569. [PMID: 37177773 PMCID: PMC10181520 DOI: 10.3390/s23094569] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 05/02/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
Recent developments in robotics have enabled humanoid robots to be used in tasks where they have to physically interact with humans, including robot-supported caregiving. This interaction-referred to as physical human-robot interaction (pHRI)-requires physical contact between the robot and the human body; one way to improve this is to use efficient sensing methods for the physical contact. In this paper, we use a flexible tactile sensing array and integrate it as a tactile skin for the humanoid robot HRP-4C. As the sensor can take any shape due to its flexible property, a particular focus is given on its spatial calibration, i.e., the determination of the locations of the sensor cells and their normals when attached to the robot. For this purpose, a novel method of spatial calibration using B-spline surfaces has been developed. We demonstrate with two methods that this calibration method gives a good approximation of the sensor position and show that our flexible tactile sensor can be fully integrated on a robot and used as input for robot control tasks. These contributions are a first step toward the use of flexible tactile sensors in pHRI applications.
Collapse
Affiliation(s)
- Sélim Chefchaouni Moussaoui
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- CNRS-AIST Joint Robotics Laboratory (JRL), AIST, Tsukuba 305-8560, Japan
| | - Rafael Cisneros-Limón
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- CNRS-AIST Joint Robotics Laboratory (JRL), AIST, Tsukuba 305-8560, Japan
| | - Hiroshi Kaminaga
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- CNRS-AIST Joint Robotics Laboratory (JRL), AIST, Tsukuba 305-8560, Japan
| | - Mehdi Benallegue
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- CNRS-AIST Joint Robotics Laboratory (JRL), AIST, Tsukuba 305-8560, Japan
| | - Taiki Nobeshima
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- Human Augmentation Research Center (HARC), AIST, Kashiwa 277-0882, Japan
| | - Shusuke Kanazawa
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- Human Augmentation Research Center (HARC), AIST, Kashiwa 277-0882, Japan
| | - Fumio Kanehiro
- National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8560, Japan
- CNRS-AIST Joint Robotics Laboratory (JRL), AIST, Tsukuba 305-8560, Japan
| |
Collapse
|