1
|
Wang M, Sasaki Y, Sakagami R, Minamikawa T, Tsuda M, Ueno R, Deguchi S, Negoro R, So K, Higuchi Y, Yokokawa R, Takayama K, Yamashita F. Perfluoropolyether-Based Gut-Liver-on-a-Chip for the Evaluation of First-Pass Metabolism and Oral Bioavailability of Drugs. ACS Biomater Sci Eng 2024; 10:4635-4644. [PMID: 38822812 DOI: 10.1021/acsbiomaterials.4c00605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2024]
Abstract
In the evolving field of drug discovery and development, multiorgans-on-a-chip and microphysiological systems are gaining popularity owing to their ability to emulate in vivo biological environments. Among the various gut-liver-on-a-chip systems for studying oral drug absorption, the chip developed in this study stands out with two distinct features: incorporation of perfluoropolyether (PFPE) to effectively mitigate drug sorption and a unique enterohepatic single-passage system, which simplifies the analysis of first-pass metabolism and oral bioavailability. By introducing a bolus drug injection into the liver compartment, hepatic extraction alone could be evaluated, further enhancing our estimation of intestinal availability. In a study on midazolam (MDZ), PFPE-based chips showed more than 20-times the appearance of intact MDZ in the liver compartment effluent compared to PDMS-based counterparts. Notably, saturation of hepatic metabolism at higher concentrations was confirmed by observations when the dose was reduced from 200 μM to 10 μM. This result was further emphasized when the metabolism was significantly inhibited by the coadministration of ketoconazole. Our chip, which is designed to minimize the dead volume between the gut and liver compartments, is adept at sensitively observing the saturation of metabolism and the effect of inhibitors. Using genome-edited CYP3A4/UGT1A1-expressing Caco-2 cells, the estimates for intestinal and hepatic availabilities were 0.96 and 0.82, respectively; these values are higher than the known human in vivo values. Although the metabolic activity in each compartment can be further improved, this gut-liver-on-a-chip can not only be used to evaluate oral bioavailability but also to carry out individual assessment of both intestinal and hepatic availability.
Collapse
Affiliation(s)
- Mengyang Wang
- Department of Drug Delivery Research, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Yuko Sasaki
- Department of Applied Pharmaceutics and Pharmacokinetics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Rena Sakagami
- Department of Drug Delivery Research, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Tomotaka Minamikawa
- Department of Applied Pharmaceutics and Pharmacokinetics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Masahiro Tsuda
- Department of Applied Pharmaceutics and Pharmacokinetics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Ryohei Ueno
- Department of Micro Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan
| | - Sayaka Deguchi
- Center for iPS Cell Research and Application, Kyoto University, Kyoto 606-8507, Japan
| | - Ryosuke Negoro
- Laboratory of Molecular Pharmacokinetics, College of Pharmaceutical Sciences, Ritsumeikan University, Shiga 525-8577, Japan
| | - Kanako So
- Department of Applied Pharmaceutics and Pharmacokinetics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Yuriko Higuchi
- Department of Drug Delivery Research, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Ryuji Yokokawa
- Department of Micro Engineering, Graduate School of Engineering, Kyoto University, Kyoto 615-8540, Japan
| | - Kazuo Takayama
- Center for iPS Cell Research and Application, Kyoto University, Kyoto 606-8507, Japan
| | - Fumiyoshi Yamashita
- Department of Drug Delivery Research, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
- Department of Applied Pharmaceutics and Pharmacokinetics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| |
Collapse
|
2
|
Scheidecker B, Poulain S, Sugimoto M, Arakawa H, Kim SH, Kawanishi T, Kato Y, Danoy M, Nishikawa M, Sakai Y. Mechanobiological stimulation in organ-on-a-chip systems reduces hepatic drug metabolic capacity in favor of regenerative specialization. Biotechnol Bioeng 2024; 121:1435-1452. [PMID: 38184801 DOI: 10.1002/bit.28653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/08/2024]
Abstract
Hepatic physiology depends on the liver's complex structural composition which among others, provides high oxygen supply rates, locally differential oxygen tension, endothelial paracrine signaling, as well as residual hemodynamic shear stress to resident hepatocytes. While functional improvements were shown by implementing these factors into hepatic culture systems, direct cause-effect relationships are often not well characterized-obfuscating their individual contribution in more complex microphysiological systems. By comparing increasingly complex hepatic in vitro culture systems that gradually implement these parameters, we investigate the influence of the cellular microenvironment to overall hepatic functionality in pharmacological applications. Here, hepatocytes were modulated in terms of oxygen tension and supplementation, endothelial coculture, and exposure to fluid shear stress delineated from oxygen influx. Results from transcriptomic and metabolomic evaluation indicate that particularly oxygen supply rates are critical to enhance cellular functionality-with cellular drug metabolism remaining comparable to physiological conditions after prolonged static culture. Endothelial signaling was found to be a major contributor to differential phenotype formation known as metabolic zonation, indicated by WNT pathway activity. Lastly, oxygen-delineated shear stress was identified to direct cellular fate towards increased hepatic plasticity and regenerative phenotypes at the cost of drug metabolic functionality - in line with regenerative effects observed in vivo. With these results, we provide a systematic evaluation of critical parameters and their impact in hepatic systems. Given their adherence to physiological effects in vivo, this highlights the importance of their implementation in biomimetic devices, such as organ-on-a-chip systems. Considering recent advances in basic liver biology, direct translation of physiological structures into in vitro models is a promising strategy to expand the capabilities of pharmacological models.
Collapse
Affiliation(s)
| | - Stéphane Poulain
- Institute of Industrial Science, University of Tokyo, Tokyo, Japan
| | - Masahiro Sugimoto
- Institute for Advanced Biosciences, Keio University, Yamagata, Japan
- Institute of Medical Science, Tokyo Medical University, Tokyo, Japan
| | - Hiroshi Arakawa
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Soo H Kim
- Institute of Industrial Science, University of Tokyo, Tokyo, Japan
| | - Takumi Kawanishi
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Yukio Kato
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Mathieu Danoy
- Department of Chemical System Engineering, University of Tokyo, Tokyo, Japan
| | - Masaki Nishikawa
- Department of Chemical System Engineering, University of Tokyo, Tokyo, Japan
| | - Yasuyuki Sakai
- Department of Chemical System Engineering, University of Tokyo, Tokyo, Japan
| |
Collapse
|
3
|
Scheidecker B, Poulain S, Sugimoto M, Kido T, Kawanishi T, Miyajima A, Kim SH, Arakawa H, Kato Y, Nishikawa M, Danoy M, Sakai Y, Leclerc E. Dynamic, IPSC-derived hepatic tissue tri-culture system for the evaluation of liver physiology in vitro. Biofabrication 2024; 16:025037. [PMID: 38447229 DOI: 10.1088/1758-5090/ad30c5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 03/06/2024] [Indexed: 03/08/2024]
Abstract
Availability of hepatic tissue for the investigation of metabolic processes is severely limited. While primary hepatocytes or animal models are widely used in pharmacological applications, a change in methodology towards more sustainable and ethical assays is highly desirable. Stem cell derived hepatic cells are generally regarded as a viable alternative for the above model systems, if current limitations in functionality and maturation can be overcome. By combining microfluidic organ-on-a-chip technology with individually differentiated, multicellular hepatic tissue fractions, we aim to improve overall functionality of hepatocyte-like cells, as well as evaluate cellular composition and interactions with non-parenchymal cell populations towards the formation of mature liver tissue. Utilizing a multi-omic approach, we show the improved maturation profiles of hepatocyte-like cells maintained in a dynamic microenvironment compared to standard tissue culture setups without continuous perfusion. In order to evaluate the resulting tissue, we employ single cell sequencing to distinguish formed subpopulations and spatial localization. While cellular input was strictly defined based on established differentiation protocols of parenchyma, endothelial and stellate cell fractions, resulting hepatic tissue was shown to comprise a complex mixture of epithelial and non-parenchymal fractions with specific local enrichment of phenotypes along the microchannel. Following this approach, we show the importance of passive, paracrine developmental processes in tissue formation. Using such complex tissue models is a crucial first step to develop stem cell-derivedin vitrosystems that can compare functionally with currently used pharmacological and toxicological applications.
Collapse
Affiliation(s)
- Benedikt Scheidecker
- CNRS UMI 2820, Institute of Industrial Science, University of Tokyo, 153-8505 Tokyo, Japan
| | - Stéphane Poulain
- Institute of Industrial Science, University of Tokyo, 153-8505 Tokyo, Japan
| | - Masahiro Sugimoto
- Institute for Advanced Biosciences, Keio University, 997-0035 Yamagata, Japan
- Institute of Medical Science, Tokyo Medical University, 160-8402 Tokyo, Japan
| | - Taketomo Kido
- Institute for Quantitative Biosciences, University of Tokyo, 113-0032 Tokyo, Japan
| | - Takumi Kawanishi
- School of Pharmaceutical Sciences, Kanazawa University, 920-1102 Kanazawa, Japan
| | - Atsushi Miyajima
- Institute for Quantitative Biosciences, University of Tokyo, 113-0032 Tokyo, Japan
| | - Soo Hyeon Kim
- Institute of Industrial Science, University of Tokyo, 153-8505 Tokyo, Japan
| | - Hiroshi Arakawa
- School of Pharmaceutical Sciences, Kanazawa University, 920-1102 Kanazawa, Japan
| | - Yukio Kato
- School of Pharmaceutical Sciences, Kanazawa University, 920-1102 Kanazawa, Japan
| | - Masaki Nishikawa
- Department of Chemical System Engineering, University of Tokyo, 113-8654 Tokyo, Japan
| | - Mathieu Danoy
- Department of Chemical System Engineering, University of Tokyo, 113-8654 Tokyo, Japan
| | - Yasuyuki Sakai
- Department of Chemical System Engineering, University of Tokyo, 113-8654 Tokyo, Japan
| | - Eric Leclerc
- CNRS UMI 2820, Institute of Industrial Science, University of Tokyo, 153-8505 Tokyo, Japan
- CNRS UMR 7338, Laboratoire de Biomécanique et Bioingénierie, Université de Technologies de Compiègne, 60203 Compiègne, France
| |
Collapse
|
4
|
Mahdavi R, Hashemi-Najafabadi S, Ghiass MA, Adiels CB. Microfluidic design for in-vitro liver zonation-a numerical analysis using COMSOL Multiphysics. Med Biol Eng Comput 2024; 62:121-133. [PMID: 37733153 DOI: 10.1007/s11517-023-02936-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 09/09/2023] [Indexed: 09/22/2023]
Abstract
The liver is one of the most important organs, with a complex physiology. Current in-vitro approaches are not accurate for disease modeling and drug toxicity research. One of those features is liver zonation, where cells display different physiological states due to different levels of oxygen and nutrient supplements. Organ-on-a-chip technology employs microfluidic platforms that enable a controlled environment for in-vitro cell culture. In this study, we propose a microfluidic design embedding a gas channel (of ambient air), creating an oxygen gradient. We numerically simulate different flow rates and cell densities with the COMSOL Multiphysics package considering cell-specific consumption rates of oxygen and glucose. We establish the cell density and flow rate for optimum oxygen and glucose distribution in the cell culture chamber. Furthermore, we show that a physiologically relevant concentration of oxygen and glucose in the chip is reached after 24 h and 30 min, respectively. The proposed microfluidic design and optimal parameters we identify in this paper provide a tool for in-vitro liver zonation studies. However, the microfluidic design is not exclusively for liver cell experiments but is foreseen to be applicable in cell studies where different gas concentration gradients are critical, e.g., studying hypoxia or toxic gas impact.
Collapse
Affiliation(s)
- Reza Mahdavi
- Biotechnology Department, Faculty of Chemical Engineering, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran
| | - Sameereh Hashemi-Najafabadi
- Biomedical Engineering Department, Faculty of Chemical Engineering, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran.
| | - Mohammad Adel Ghiass
- Tissue Engineering Department, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran
| | | |
Collapse
|
5
|
Bakuova N, Toktarkan S, Dyussembinov D, Azhibek D, Rakhymzhanov A, Kostas K, Kulsharova G. Design, Simulation, and Evaluation of Polymer-Based Microfluidic Devices via Computational Fluid Dynamics and Cell Culture "On-Chip". BIOSENSORS 2023; 13:754. [PMID: 37504152 PMCID: PMC10377015 DOI: 10.3390/bios13070754] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/10/2023] [Accepted: 07/11/2023] [Indexed: 07/29/2023]
Abstract
Organ-on-a-chip (OoC) technology has experienced exponential growth driven by the need for a better understanding of in-organ processes and the development of novel approaches. This paper investigates and compares the flow behavior and filling characteristics of two microfluidic liver-on-a-chip devices using Computational Fluid Dynamics (CFD) analysis and experimental cell culture growth based on the Huh7 cell line. The conducted computational analyses for the two chips showed that the elliptical chamber chip proposed herein offers improved flow and filling characteristics in comparison with the previously presented circular chamber chip. Huh7 hepatoma cells were cultured in the microfluidic devices for 24 h under static fluidic conditions and for 24 h with a flow rate of 3 μL·min-1. Biocompatibility, continuous flow, and biomarker studies showed cell attachment in the chips, confirming the cell viability and their consistent cell growth. The study successfully analyzed the fluid flow behavior, filling characteristics, and biocompatibility of liver-on-a-chip prototype devices, providing valuable insights to improve design and performance and advance alternative methods of in vitro testing.
Collapse
Affiliation(s)
- Nurzhanna Bakuova
- Department of Electrical and Computer Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| | - Sultanali Toktarkan
- Department of Electrical and Computer Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| | - Darkhan Dyussembinov
- Department of Mechanical and Aerospace Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| | - Dulat Azhibek
- Department of Electrical and Computer Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| | - Almas Rakhymzhanov
- Nanofabrication Core Lab, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| | - Konstantinos Kostas
- Department of Mechanical and Aerospace Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| | - Gulsim Kulsharova
- Department of Electrical and Computer Engineering, School of Engineering and Digital Sciences, Nazarbayev University, Astana 010000, Kazakhstan
| |
Collapse
|
6
|
Otumala AE, Hellen DJ, Luna CA, Delgado P, Dissanayaka A, Ugwumadu C, Oshinowo O, Islam MM, Shen L, Karpen SJ, Myers DR. Opportunities and considerations for studying liver disease with microphysiological systems on a chip. LAB ON A CHIP 2023; 23:2877-2898. [PMID: 37282629 DOI: 10.1039/d2lc00940d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Advances in microsystem engineering have enabled the development of highly controlled models of the liver that better recapitulate the unique in vivo biological conditions. In just a few short years, substantial progress has been made in creating complex mono- and multi-cellular models that mimic key metabolic, structural, and oxygen gradients crucial for liver function. Here we review: 1) the state-of-the-art in liver-centric microphysiological systems and 2) the array of liver diseases and pressing biological and therapeutic challenges which could be investigated with these systems. The engineering community has unique opportunities to innovate with new liver-on-a-chip devices and partner with biomedical researchers to usher in a new era of understanding of the molecular and cellular contributors to liver diseases and identify and test rational therapeutic modalities.
Collapse
Affiliation(s)
- Adiya E Otumala
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Dominick J Hellen
- Department of Pediatrics, Division of Pediatric Gastroenterology, Hepatology and Nutrition, Emory University School of Medicine, Children's Healthcare of Atlanta, Atlanta, Georgia, USA
| | - C Alessandra Luna
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Priscilla Delgado
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Anjana Dissanayaka
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Chidozie Ugwumadu
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Oluwamayokun Oshinowo
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Md Mydul Islam
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Luyao Shen
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| | - Saul J Karpen
- Department of Pediatrics, Division of Pediatric Gastroenterology, Hepatology and Nutrition, Emory University School of Medicine, Children's Healthcare of Atlanta, Atlanta, Georgia, USA
| | - David R Myers
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, 1760 Haygood Dr, Suite E-160, Rm E-156, Atlanta, GA, 30332, USA.
- Department of Pediatrics, Division of Pediatric Hematology/Oncology, Aflac Cancer Center and Blood Disorders Service of Children's Healthcare of Atlanta, Emory University School of Medicine, Atlanta, GA 30322, USA
| |
Collapse
|
7
|
Fortin CL, McCray TN, Saxton SH, Johansson F, Andino CB, Mene J, Wang Y, Stevens KR. Temporal Dynamics of Metabolic Acquisition in Grafted Engineered Human Liver Tissue. Adv Biol (Weinh) 2023; 7:e2200208. [PMID: 36328790 PMCID: PMC10259871 DOI: 10.1002/adbi.202200208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 09/23/2022] [Indexed: 11/06/2022]
Abstract
Liver disease affects millions globally, and end-stage liver failure is only cured by organ transplant. Unfortunately, there is a growing shortage of donor organs as well as inequitable access to transplants across populations. Engineered liver tissue grafts that supplement or replace native organ function can address this challenge. While engineered liver tissues have been successfully engrafted previously, the extent to which these tissues express human liver metabolic genes and proteins remains unknown. Here, it is built engineered human liver tissues and characterized their engraftment, expansion, and metabolic phenotype at sequential stages post-implantation by RNA sequencing, histology, and host serology. Expression of metabolic genes is observed at weeks 1-2, followed by the cellular organization into hepatic cords by weeks 4-9.5. Furthermore, grafted engineered tissues exhibited progressive spatially restricted expression of critical functional proteins known to be zonated in the native human liver. This is the first report of engineered human liver tissue zonation after implantation in vivo, which can have important translational implications for this field.
Collapse
Affiliation(s)
- Chelsea L Fortin
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, 98195, USA
| | - Tara N McCray
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
| | - Sarah H Saxton
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
| | - Fredrik Johansson
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
| | - Christian B Andino
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
| | - Jonathan Mene
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
| | - Yuliang Wang
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Computer Science & Engineering, University of Washington, Seattle, Washington, 98195, USA
| | - Kelly R Stevens
- Institute for Stem Cell & Regenerative Medicine, University of Washington, Seattle, Washington, 98109, USA
- Department of Bioengineering, University of Washington, Seattle, Washington, 98105, USA
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, 98195, USA
| |
Collapse
|
8
|
Liu S, Kumari S, He H, Mishra P, Singh BN, Singh D, Liu S, Srivastava P, Li C. Biosensors integrated 3D organoid/organ-on-a-chip system: A real-time biomechanical, biophysical, and biochemical monitoring and characterization. Biosens Bioelectron 2023; 231:115285. [PMID: 37058958 DOI: 10.1016/j.bios.2023.115285] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 03/25/2023] [Accepted: 03/28/2023] [Indexed: 04/16/2023]
Abstract
As a full-fidelity simulation of human cells, tissues, organs, and even systems at the microscopic scale, Organ-on-a-Chip (OOC) has significant ethical advantages and development potential compared to animal experiments. The need for the design of new drug high-throughput screening platforms and the mechanistic study of human tissues/organs under pathological conditions, the evolving advances in 3D cell biology and engineering, etc., have promoted the updating of technologies in this field, such as the iteration of chip materials and 3D printing, which in turn facilitate the connection of complex multi-organs-on-chips for simulation and the further development of technology-composite new drug high-throughput screening platforms. As the most critical part of organ-on-a-chip design and practical application, verifying the success of organ model modeling, i.e., evaluating various biochemical and physical parameters in OOC devices, is crucial. Therefore, this paper provides a logical and comprehensive review and discussion of the advances in organ-on-a-chip detection and evaluation technologies from a broad perspective, covering the directions of tissue engineering scaffolds, microenvironment, single/multi-organ function, and stimulus-based evaluation, and provides a more comprehensive review of the progress in the significant organ-on-a-chip research areas in the physiological state.
Collapse
Affiliation(s)
- Shan Liu
- Sichuan Provincial Key Laboratory for Human Disease Gene Study, Department of Medical Genetics, Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, 610072, China
| | - Shikha Kumari
- School of Biochemical Engineering, IIT BHU, Varanasi, Uttar Pradesh, India
| | - Hongyi He
- West China School of Medicine & West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Parichita Mishra
- Department of Ageing Research, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India
| | - Bhisham Narayan Singh
- Department of Ageing Research, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, 576104, Karnataka, India
| | - Divakar Singh
- School of Biochemical Engineering, IIT BHU, Varanasi, Uttar Pradesh, India
| | - Sutong Liu
- Juxing College of Digital Economics, Haikou University of Economics, Haikou, 570100, China
| | - Pradeep Srivastava
- School of Biochemical Engineering, IIT BHU, Varanasi, Uttar Pradesh, India.
| | - Chenzhong Li
- Biomedical Engineering, School of Medicine, The Chinese University of Hong Kong(Shenzhen), Shenzhen, 518172, China.
| |
Collapse
|
9
|
Kaur I, Vasudevan A, Rawal P, Tripathi DM, Ramakrishna S, Kaur S, Sarin SK. Primary Hepatocyte Isolation and Cultures: Technical Aspects, Challenges and Advancements. Bioengineering (Basel) 2023; 10:131. [PMID: 36829625 PMCID: PMC9952008 DOI: 10.3390/bioengineering10020131] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 01/11/2023] [Accepted: 01/13/2023] [Indexed: 01/20/2023] Open
Abstract
Hepatocytes are differentiated cells that account for 80% of the hepatic volume and perform all major functions of the liver. In vivo, after an acute insult, adult hepatocytes retain their ability to proliferate and participate in liver regeneration. However, in vitro, prolonged culture and proliferation of viable and functional primary hepatocytes have remained the major and the most challenging goal of hepatocyte-based cell therapies and liver tissue engineering. The first functional cultures of rat primary hepatocytes between two layers of collagen gel, also termed as the "sandwich cultures", were reported in 1989. Since this study, several technical developments including choice of hydrogels, type of microenvironment, growth factors and culture conditions, mono or co-cultures of hepatocytes along with other supporting cell types have evolved for both rat and human primary hepatocytes in recent years. All these improvements have led to a substantial improvement in the number, life-span and hepatic functions of these cells in vitro for several downstream applications. In the current review, we highlight the details, limitations and prospects of different technical strategies being used in primary hepatocyte cultures. We discuss the use of newer biomaterials as scaffolds for efficient culture of primary hepatocytes. We also describe the derivation of mature hepatocytes from other cellular sources such as induced pluripotent stem cells, bone marrow stem cells and 3D liver organoids. Finally, we also explain the use of perfusion-based bioreactor systems and bioengineering strategies to support the long-term function of hepatocytes in 3D conditions.
Collapse
Affiliation(s)
- Impreet Kaur
- Department of Molecular and Cellular Medicine, Institute of Liver and Biliary Sciences, New Delhi 110070, India
| | - Ashwini Vasudevan
- Department of Molecular and Cellular Medicine, Institute of Liver and Biliary Sciences, New Delhi 110070, India
| | - Preety Rawal
- School of Biotechnology, Gautam Buddha University, Greater Noida 201312, India
| | - Dinesh M. Tripathi
- Department of Molecular and Cellular Medicine, Institute of Liver and Biliary Sciences, New Delhi 110070, India
| | - Seeram Ramakrishna
- Department of Mechanical Engineering, National University of Singapore, Singapore 117581, Singapore
| | - Savneet Kaur
- Department of Molecular and Cellular Medicine, Institute of Liver and Biliary Sciences, New Delhi 110070, India
| | - Shiv K. Sarin
- Department of Molecular and Cellular Medicine, Institute of Liver and Biliary Sciences, New Delhi 110070, India
| |
Collapse
|
10
|
Biagini F, Daddi C, Calvigioni M, De Maria C, Zhang YS, Ghelardi E, Vozzi G. Designs and methodologies to recreate in vitro human gut microbiota models. Biodes Manuf 2022. [DOI: 10.1007/s42242-022-00210-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
AbstractThe human gut microbiota is widely considered to be a metabolic organ hidden within our bodies, playing a crucial role in the host’s physiology. Several factors affect its composition, so a wide variety of microbes residing in the gut are present in the world population. Individual excessive imbalances in microbial composition are often associated with human disorders and pathologies, and new investigative strategies to gain insight into these pathologies and define pharmaceutical therapies for their treatment are needed. In vitro models of the human gut microbiota are commonly used to study microbial fermentation patterns, community composition, and host-microbe interactions. Bioreactors and microfluidic devices have been designed to culture microorganisms from the human gut microbiota in a dynamic environment in the presence or absence of eukaryotic cells to interact with. In this review, we will describe the overall elements required to create a functioning, reproducible, and accurate in vitro culture of the human gut microbiota. In addition, we will analyze some of the devices currently used to study fermentation processes and relationships between the human gut microbiota and host eukaryotic cells.
Graphic abstract
Collapse
|
11
|
Zandi Shafagh R, Youhanna S, Keulen J, Shen JX, Taebnia N, Preiss LC, Klein K, Büttner FA, Bergqvist M, van der Wijngaart W, Lauschke VM. Bioengineered Pancreas-Liver Crosstalk in a Microfluidic Coculture Chip Identifies Human Metabolic Response Signatures in Prediabetic Hyperglycemia. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2203368. [PMID: 36285680 PMCID: PMC9731722 DOI: 10.1002/advs.202203368] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/05/2022] [Indexed: 05/19/2023]
Abstract
Aberrant glucose homeostasis is the most common metabolic disturbance affecting one in ten adults worldwide. Prediabetic hyperglycemia due to dysfunctional interactions between different human tissues, including pancreas and liver, constitutes the largest risk factor for the development of type 2 diabetes. However, this early stage of metabolic disease has received relatively little attention. Microphysiological tissue models that emulate tissue crosstalk offer emerging opportunities to study metabolic interactions. Here, a novel modular multitissue organ-on-a-chip device is presented that allows for integrated and reciprocal communication between different 3D primary human tissue cultures. Precisely controlled heterologous perfusion of each tissue chamber is achieved through a microfluidic single "synthetic heart" pneumatic actuation unit connected to multiple tissue chambers via specific configuration of microchannel resistances. On-chip coculture experiments of organotypic primary human liver spheroids and intact primary human islets demonstrate insulin secretion and hepatic insulin response dynamics at physiological timescales upon glucose challenge. Integration of transcriptomic analyses with promoter motif activity data of 503 transcription factors reveals tissue-specific interacting molecular networks that underlie β-cell stress in prediabetic hyperglycemia. Interestingly, liver and islet cultures show surprising counter-regulation of transcriptional programs, emphasizing the power of microphysiological coculture to elucidate the systems biology of metabolic crosstalk.
Collapse
Affiliation(s)
- Reza Zandi Shafagh
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
- Division of Micro- and Nanosystems, KTH Royal Institute of Technology, Stockholm, 10044, Sweden
| | - Sonia Youhanna
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
| | - Jibbe Keulen
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
- Division of Micro- and Nanosystems, KTH Royal Institute of Technology, Stockholm, 10044, Sweden
- Dr Margarete Fischer-Bosch Institute of Clinical Pharmacology, 70376, Stuttgart, Germany
- University of Tuebingen, 72074, Tuebingen, Germany
| | - Joanne X Shen
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
| | - Nayere Taebnia
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
| | - Lena C Preiss
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
- Department of Drug Metabolism and Pharmacokinetics (DMPK), The Healthcare Business of Merck KGaA, 64293, Darmstadt, Germany
| | - Kathrin Klein
- Dr Margarete Fischer-Bosch Institute of Clinical Pharmacology, 70376, Stuttgart, Germany
- University of Tuebingen, 72074, Tuebingen, Germany
| | - Florian A Büttner
- Dr Margarete Fischer-Bosch Institute of Clinical Pharmacology, 70376, Stuttgart, Germany
- University of Tuebingen, 72074, Tuebingen, Germany
| | - Mikael Bergqvist
- Division of Micro- and Nanosystems, KTH Royal Institute of Technology, Stockholm, 10044, Sweden
| | | | - Volker M Lauschke
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, 17711, Sweden
- Dr Margarete Fischer-Bosch Institute of Clinical Pharmacology, 70376, Stuttgart, Germany
- University of Tuebingen, 72074, Tuebingen, Germany
| |
Collapse
|
12
|
Wang M, Tsuda M, Deguchi S, Higuchi Y, So K, Torisawa YS, Takayama K, Yamashita F. Application of perfluoropolyether elastomers in microfluidic drug metabolism assays. Int J Pharm 2022; 627:122253. [DOI: 10.1016/j.ijpharm.2022.122253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 09/09/2022] [Accepted: 09/25/2022] [Indexed: 11/26/2022]
|
13
|
Dalsbecker P, Beck Adiels C, Goksör M. Liver-on-a-chip devices: the pros and cons of complexity. Am J Physiol Gastrointest Liver Physiol 2022; 323:G188-G204. [PMID: 35819853 DOI: 10.1152/ajpgi.00346.2021] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Physiologically relevant and broadly applicable liver cell culture platforms are of great importance in both drug development and disease modeling. Organ-on-a-chip systems offer a promising alternative to conventional, static two-dimensional (2-D) cultures, providing much-needed cues such as perfusion, shear stress, and three-dimensional (3-D) cell-cell communication. However, such devices cover a broad range of complexity both in manufacture and in implementation. In this review, we summarize the key features of the human liver that should be reflected in a physiologically relevant liver-on-a-chip model. We also discuss different material properties of importance in producing liver-on-a-chip devices and summarize recent and current progress in the field, highlighting different types of devices at different levels of complexity.
Collapse
Affiliation(s)
| | | | - Mattias Goksör
- Department of Physics, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
14
|
Hoyle H, Stenger C, Przyborski S. Design considerations of benchtop fluid flow bioreactors for bio-engineered tissue equivalents in vitro. BIOMATERIALS AND BIOSYSTEMS 2022; 8:100063. [PMID: 36824373 PMCID: PMC9934498 DOI: 10.1016/j.bbiosy.2022.100063] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/08/2022] [Accepted: 08/30/2022] [Indexed: 10/14/2022] Open
Abstract
One of the major aims of bio-engineering tissue equivalents in vitro is to create physiologically relevant culture conditions to accurately recreate the cellular microenvironment. This often includes incorporation of factors such as the extracellular matrix, co-culture of multiple cell types and three-dimensional culture techniques. These advanced techniques can recapitulate some of the properties of tissue in vivo, however fluid flow is a key aspect that is often absent. Fluid flow can be introduced into cell and tissue culture using bioreactors, which are becoming increasingly common as we seek to produce increasingly accurate tissue models. Bespoke technology is continuously being developed to tailor systems for specific applications and to allow compatibility with a range of culture techniques. For effective perfusion of a tissue culture many parameters can be controlled, ranging from impacts of the fluid flow such as increased shear stress and mass transport, to potentially unwanted side effects such as temperature fluctuations. A thorough understanding of these properties and their implications on the culture model can aid with a more accurate interpretation of results. Improved and more complete characterisation of bioreactor properties will also lead to greater accuracy when reporting culture conditions in protocols, aiding experimental reproducibility, and allowing more precise comparison of results between different systems. In this review we provide an analysis of the different factors involved in the development of benchtop flow bioreactors and their potential biological impacts across a range of applications.
Collapse
Key Words
- 3D, three-dimensional
- ABS, acrylonitrile butadiene styrene
- ALI, air-liquid interface
- Bioreactors
- CFD, computational fluid dynamics
- Cell culture
- ECM, extracellular matrix
- FDM, fused deposition modelling
- Fluid flow
- PC, polycarbonate
- PET, polyethylene terephthalate
- PLA, polylactic acid
- PTFE, polytetrafluoroethylene
- SLA, stereolithography
- Tissue engineering
- UL, unstirred layer
- UV, ultraviolet light
Collapse
Affiliation(s)
- H.W. Hoyle
- Department of Biosciences, Durham University, South Road, Durham DH1 3LE, UK
| | - C.M.L. Stenger
- Department of Biosciences, Durham University, South Road, Durham DH1 3LE, UK
| | - S.A. Przyborski
- Department of Biosciences, Durham University, South Road, Durham DH1 3LE, UK,NETPark Incubator, Reprocell Europe Ltd., Thomas Wright Way, Sedgefield TS21 3FD, UK,Corresponding author at: Department of Biosciences, Durham University, South Road, Durham DH1 3LE, UK.
| |
Collapse
|
15
|
Sugiura S, Satoh T, Shin K, Onuki-Nagasaki R, Kanamori T. Perfusion culture of multi-layered HepG2 hepatocellular carcinoma cells in a pressure-driven microphysiological system. J Biosci Bioeng 2022; 134:348-355. [PMID: 35963667 DOI: 10.1016/j.jbiosc.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/03/2022] [Accepted: 07/04/2022] [Indexed: 11/25/2022]
Abstract
Here we report the perfusion culture of a multi-layered tissue composed of HepG2 cells (a human hepatoma line) in a pressure-driven microphysiological system (PD-MPS), which we developed previously as a multi-throughput perfusion culture platform. The perfusion culture of multi-layered tissue model was constructed by inserting a modified commercially available permeable membrane insert into the PD-MPS. HepG2 cells were layered on the membrane, and culture medium was perfused both through and below the membrane. The seeded density (number of cells/cm2) of the culture model is 70 times that of static culture in a conventional 35-mm culture dish. Pressure-driven circulation of the medium in our compact device (8.6 × 7.0 × 4.5 cm3), which comprised two perfusion-culture modules and a pneumatic connection port, enabled perfusion culture of two multi-layered tissues (initially 1 × 105 cells). To obtain insight into the basic functionality of the multi-layered tissues as hepatocytes, we compared albumin production and urea synthesis between perfusion cultures and static cultures. The HepG2 cells grew and secreted increasing amounts of albumin throughout 20 days of perfusion culture, whereas albumin secretion did not increase under static culture conditions. In addition, on day 20, the amount of albumin secreted by the HepG2 cells in the microfluidic device was 68% of that in the conventional culture dish, which was seeded with the same number of cells but had a 70 times larger culture area. These features of high-density culture of functioning cells in a compact device support the application of PD-MPS in single- and multi-organ MPS.
Collapse
Affiliation(s)
- Shinji Sugiura
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan.
| | - Taku Satoh
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan; Stem Cell Evaluation Technology Research Association, Astellas Pharma, 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - Kazumi Shin
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| | - Reiko Onuki-Nagasaki
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan; Stem Cell Evaluation Technology Research Association, Astellas Pharma, 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - Toshiyuki Kanamori
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| |
Collapse
|
16
|
A new insight into a thermoplastic microfluidic device aimed at improvement of oxygenation process and avoidance of shear stress during cell culture. Biomed Microdevices 2022; 24:15. [PMID: 35277762 PMCID: PMC8917112 DOI: 10.1007/s10544-022-00615-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/18/2022] [Indexed: 01/01/2023]
Abstract
Keeping the oxygen concentration at the desired physiological limits is a challenging task in cellular microfluidic devices. A good knowledge of affecting parameters would be helpful to control the oxygen delivery to cells. This study aims to provide a fundamental understanding of oxygenation process within a hydrogel-based microfluidic device considering simultaneous mass transfer, medium flow, and cellular consumption. For this purpose, the role of geometrical and hydrodynamic properties was numerically investigated. The results are in good agreement with both numerical and experimental data in the literature. The obtained results reveal that increasing the microchannel height delays the oxygen depletion in the absence of media flow. We also observed that increasing the medium flow rate increases the oxygen concentration in the device; however, it leads to high maximum shear stress. A novel pulsatile medium flow injection pattern is introduced to reduce detrimental effect of the applied shear stress on the cells.
Collapse
|
17
|
Kanabekova P, Kadyrova A, Kulsharova G. Microfluidic Organ-on-a-Chip Devices for Liver Disease Modeling In Vitro. MICROMACHINES 2022; 13:428. [PMID: 35334720 PMCID: PMC8950395 DOI: 10.3390/mi13030428] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 03/05/2022] [Accepted: 03/08/2022] [Indexed: 12/12/2022]
Abstract
Mortality from liver disease conditions continues to be very high. As liver diseases manifest and progress silently, prompt measures after diagnosis are essential in the treatment of these conditions. Microfluidic organs-on-chip platforms have significant potential for the study of the pathophysiology of liver diseases in vitro. Different liver-on-a-chip microphysiological platforms have been reported to study cell-signaling pathways such as those activating stellate cells within liver diseases. Moreover, the drug efficacy for liver conditions might be evaluated on a cellular metabolic level. Here, we present a comprehensive review of microphysiological platforms used for modelling liver diseases. First, we briefly introduce the concept and importance of organs-on-a-chip in studying liver diseases in vitro, reflecting on existing reviews of healthy liver-on-a-chip platforms. Second, the techniques of cell cultures used in the microfluidic devices, including 2D, 3D, and spheroid cells, are explained. Next, the types of liver diseases (NAFLD, ALD, hepatitis infections, and drug injury) on-chip are explained for a further comprehensive overview of the design and methods of developing liver diseases in vitro. Finally, some challenges in design and existing solutions to them are reviewed.
Collapse
Affiliation(s)
- Perizat Kanabekova
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan;
| | - Adina Kadyrova
- Department of Biological Sciences, School of Sciences and Humanities, Nazarbayev University, Nur-Sultan 010000, Kazakhstan;
| | - Gulsim Kulsharova
- School of Engineering and Digital Sciences, Nazarbayev University, Nur-Sultan 010000, Kazakhstan;
| |
Collapse
|
18
|
Telles-Silva KA, Pacheco L, Komatsu S, Chianca F, Caires-Júnior LC, Araujo BHS, Goulart E, Zatz M. Applied Hepatic Bioengineering: Modeling the Human Liver Using Organoid and Liver-on-a-Chip Technologies. Front Bioeng Biotechnol 2022; 10:845360. [PMID: 35237587 PMCID: PMC8882846 DOI: 10.3389/fbioe.2022.845360] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 01/19/2022] [Indexed: 12/19/2022] Open
Abstract
The liver is the most important metabolic hub of endo and xenobiotic compounds. Pre-clinical studies using rodents to evaluate the toxicity of new drugs and cosmetics may produce inconclusive results for predicting clinical outcomes in humans, moreover being banned in the European Union. Human liver modeling using primary hepatocytes presents low reproducibility due to batch-to-batch variability, while iPSC-derived hepatocytes in monolayer cultures (2D) show reduced cellular functionality. Here we review the current status of the two most robust in vitro approaches in improving hepatocyte phenotype and metabolism while mimicking the hepatic physiological microenvironment: organoids and liver-on-chip. Both technologies are reviewed in design and manufacturing techniques, following cellular composition and functionality. Furthermore, drug screening and liver diseases modeling efficiencies are summarized. Finally, organoid and liver-on-chip technologies are compared regarding advantages and limitations, aiming to guide the selection of appropriate models for translational research and the development of such technologies.
Collapse
Affiliation(s)
- Kayque Alves Telles-Silva
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
| | - Lara Pacheco
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
| | - Sabrina Komatsu
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
| | - Fernanda Chianca
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
| | - Luiz Carlos Caires-Júnior
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
| | - Bruno Henrique Silva Araujo
- Lieber Institute for Brain Development, School of Medicine, Johns Hopkins University, Baltimore, MD, United States
| | - Ernesto Goulart
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
- *Correspondence: Ernesto Goulart, ; Mayana Zatz,
| | - Mayana Zatz
- Human Genome and Stem-Cell Research Center (HUG-CEL), Institute of Biosciences, University of Sao Paulo (USP), Sao Paulo, Brazil
- *Correspondence: Ernesto Goulart, ; Mayana Zatz,
| |
Collapse
|
19
|
From organ-on-chip to body-on-chip: The next generation of microfluidics platforms for in vitro drug efficacy and toxicity testing. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:41-91. [PMID: 35094781 DOI: 10.1016/bs.pmbts.2021.07.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The high failure rate in drug development is often attributed to the lack of accurate pre-clinical models that may lead to false discoveries and inconclusive data when the compounds are eventually tested in clinical phase. With the evolution of cell culture technologies, drug testing systems have widely improved, and today, with the emergence of microfluidics devices, drug screening seems to be at the dawn of an important revolution. An organ-on-chip allows the culture of living cells in continuously perfused microchambers to reproduce physiological functions of a particular tissue or organ. The advantages of such systems are not only their ability to recapitulate the complex biochemical interactions between different human cell types but also to incorporate physical forces, including shear stress and mechanical stretching or compression. To improve this model, and to reproduce the absorption, distribution, metabolism, and elimination process of an exogenous compound, organ-on-chips can even be linked fluidically to mimic physiological interactions between different organs, leading to the development of body-on-chips. Although these technologies are still at a young age and need to address a certain number of limitations, they already demonstrated their relevance to study the effect of drugs or toxins on organs, displaying a similar response to what is observed in vivo. The purpose of this review is to present the evolution from organ-on-chip to body-on-chip, examine their current use for drug testing and discuss their advantages and future challenges they will face in order to become an essential pillar of pharmaceutical research.
Collapse
|
20
|
Alvarez-Dominguez JR, Melton DA. Cell maturation: Hallmarks, triggers, and manipulation. Cell 2022; 185:235-249. [PMID: 34995481 PMCID: PMC8792364 DOI: 10.1016/j.cell.2021.12.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 12/03/2021] [Accepted: 12/10/2021] [Indexed: 02/06/2023]
Abstract
How cells become specialized, or "mature," is important for cell and developmental biology. While maturity is usually deemed a terminal fate, it may be more helpful to consider maturation not as a switch but as a dynamic continuum of adaptive phenotypic states set by genetic and environment programing. The hallmarks of maturity comprise changes in anatomy (form, gene circuitry, and interconnectivity) and physiology (function, rhythms, and proliferation) that confer adaptive behavior. We discuss efforts to harness their chemical (nutrients, oxygen, and growth factors) and physical (mechanical, spatial, and electrical) triggers in vitro and in vivo and how maturation strategies may support disease research and regenerative medicine.
Collapse
Affiliation(s)
- Juan R. Alvarez-Dominguez
- Department of Cell and Developmental Biology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104, USA
| | - Douglas A. Melton
- Department of Stem Cell and Regenerative Biology, Harvard Stem Cell Institute, Harvard University, Cambridge, MA 02138, USA
| |
Collapse
|
21
|
Zheng YB, Ma LD, Wu JL, Wang YM, Meng XS, Hu P, Liang QL, Xie YY, Luo GA. Design and fabrication of an integrated 3D dynamic multicellular liver-on-a-chip and its application in hepatotoxicity screening. Talanta 2022; 241:123262. [DOI: 10.1016/j.talanta.2022.123262] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 01/16/2022] [Accepted: 01/22/2022] [Indexed: 01/05/2023]
|
22
|
Sphabmixay P, Raredon MSB, Wang AJS, Lee H, Hammond PT, Fang NX, Griffith LG. High resolution stereolithography fabrication of perfusable scaffolds to enable long-term meso-scale hepatic culture for disease modeling. Biofabrication 2021; 13. [PMID: 34479229 DOI: 10.1088/1758-5090/ac23aa] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 09/03/2021] [Indexed: 12/18/2022]
Abstract
Microphysiological systems (MPS), comprising human cell cultured in formats that capture features of the three-dimensional (3D) microenvironments of native human organs under microperfusion, are promising tools for biomedical research. Here we report the development of a mesoscale physiological system (MePS) enabling the long-term 3D perfused culture of primary human hepatocytes at scales of over 106cells per MPS. A central feature of the MePS, which employs a commercially-available multiwell bioreactor for perfusion, is a novel scaffold comprising a dense network of nano- and micro-porous polymer channels, designed to provide appropriate convective and diffusive mass transfer of oxygen and other nutrients while maintaining physiological values of shear stress. The scaffold design is realized by a high resolution stereolithography fabrication process employing a novel resin. This new culture system sustains mesoscopic hepatic tissue-like cultures with greater hepatic functionality (assessed by albumin and urea synthesis, and CYP3A4 activity) and lower inflammation markers compared to comparable cultures on the commercial polystyrene scaffold. To illustrate applications to disease modeling, we established an insulin-resistant phenotype by exposing liver cells to hyperglycemic and hyperinsulinemic media. Future applications of the MePS include the co-culture of hepatocytes with resident immune cells and the integration with multiple organs to model complex liver-associated diseases.
Collapse
Affiliation(s)
- Pierre Sphabmixay
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America.,Whitehead Institute of Biomedical Research, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Micha Sam Brickman Raredon
- Department of Biomedical Engineering, Yale University, New Haven, CT, United States of America.,Vascular Biology and Therapeutics, Yale University, New Haven, CT, United States of America
| | - Alex J-S Wang
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Howon Lee
- Department of Mechanical Engineering, Seoul National University, Seoul, Korea
| | - Paula T Hammond
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America.,Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Nicholas X Fang
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Linda G Griffith
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America.,Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America.,Center for Gynepathology Research, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| |
Collapse
|
23
|
A scalable and sensitive steatosis chip with long-term perfusion of in situ differentiated HepaRG organoids. Biomaterials 2021; 275:120904. [PMID: 34119888 DOI: 10.1016/j.biomaterials.2021.120904] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 05/01/2021] [Accepted: 05/20/2021] [Indexed: 12/12/2022]
Abstract
Nonalcoholic fatty liver disease (NAFLD) is a significant liver disease without approved therapy, lacking human NAFLD models to aid drug development. Existing models are either under-performing or too complex to allow robust drug screening. Here we have developed a 100-well drug testing platform with improved HepaRG organoids formed with uniform size distribution, and differentiated in situ in a perfusion microfluidic device, SteatoChip, to recapitulate major NAFLD features. Compared with the pre-differentiated spheroids, the in situ differentiated HepaRG organoids with perfusion experience well-controlled chemical and mechanical microenvironment, and 3D cellular niche, to exhibit enhanced hepatic differentiation (albumin+ cells ratio: 66.2% in situ perfusion vs 46.1% pre-differentiation), enriched and uniform hepatocyte distribution in organoids, higher level of hepatocyte functions (5.2 folds in albumin secretion and 7.6 folds in urea synthesis), enhanced cell polarity and bile canaliculi structures. When induced with free fatty acid (FFA), cells exhibit significantly higher level of lipid accumulation (6.6 folds for in situ perfusion vs 4.4 folds for pre-differentiation), altered glucose regulation and reduced Akt phosphorylation in the organoids. SteatoChip detects reduction of steatosis when cells are incubated with three different anti-steatosis compounds, 78.5% by metformin hydrochloride, 71.3% by pioglitazone hydrochloride and 66.6% by obeticholic acid, versus the control FFA-free media (38% reduction). The precision microenvironment control in SteatoChip enables improved formation, differentiation, and function of HepaRG organoids to serve as a scalable and sensitive drug testing platform, to potentially accelerate the NAFLD drug development.
Collapse
|
24
|
Goldstein Y, Spitz S, Turjeman K, Selinger F, Barenholz Y, Ertl P, Benny O, Bavli D. Breaking the Third Wall: Implementing 3D-Printing Technics to Expand the Complexity and Abilities of Multi-Organ-on-a-Chip Devices. MICROMACHINES 2021; 12:627. [PMID: 34071476 PMCID: PMC8227399 DOI: 10.3390/mi12060627] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/19/2021] [Accepted: 05/26/2021] [Indexed: 12/12/2022]
Abstract
The understanding that systemic context and tissue crosstalk are essential keys for bridging the gap between in vitro models and in vivo conditions led to a growing effort in the last decade to develop advanced multi-organ-on-a-chip devices. However, many of the proposed devices have failed to implement the means to allow for conditions tailored to each organ individually, a crucial aspect in cell functionality. Here, we present two 3D-print-based fabrication methods for a generic multi-organ-on-a-chip device: One with a PDMS microfluidic core unit and one based on 3D-printed units. The device was designed for culturing different tissues in separate compartments by integrating individual pairs of inlets and outlets, thus enabling tissue-specific perfusion rates that facilitate the generation of individual tissue-adapted perfusion profiles. The device allowed tissue crosstalk using microchannel configuration and permeable membranes used as barriers between individual cell culture compartments. Computational fluid dynamics (CFD) simulation confirmed the capability to generate significant differences in shear stress between the two individual culture compartments, each with a selective shear force. In addition, we provide preliminary findings that indicate the feasibility for biological compatibility for cell culture and long-term incubation in 3D-printed wells. Finally, we offer a cost-effective, accessible protocol enabling the design and fabrication of advanced multi-organ-on-a-chip devices.
Collapse
Affiliation(s)
- Yoel Goldstein
- Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel;
| | - Sarah Spitz
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Keren Turjeman
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| | - Florian Selinger
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Yechezkel Barenholz
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry, Vienna University of Technology, 1040 Vienna, Austria; (S.S.); (F.S.); (P.E.)
| | - Ofra Benny
- Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem 91120, Israel;
| | - Danny Bavli
- Membrane and Liposome Research Lab, Hebrew University Hadassah Medical School, Jerusalem 91120, Israel; (K.T.); (Y.B.)
| |
Collapse
|
25
|
Zhu L, Wang Z, Xia H, Yu H. Design and Fabrication of the Vertical-Flow Bioreactor for Compaction Hepatocyte Culture in Drug Testing Application. BIOSENSORS-BASEL 2021; 11:bios11050160. [PMID: 34069382 PMCID: PMC8158682 DOI: 10.3390/bios11050160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 04/30/2021] [Accepted: 05/06/2021] [Indexed: 12/12/2022]
Abstract
The perfusion culture of primary hepatocytes has been widely adopted to build bioreactors for various applications. As a drug testing platform, a unique vertical-flow bioreactor (VfB) array was found to create the compaction culture of hepatocytes which mimicked the mechanic microenvironment in vivo while maintaining the 3D cell morphology in a 2D culture setup and enhancing the hepatic functions for a sustained culture. Here, we report the methodology in designing and fabricating the VfB to reach ideal bioreactor requirements, optimizing the VfB as a prototype for drug testing, and to demonstrate the enhanced hepatic function so as to demonstrate the performance of the bioreactor. This device enables the modular, scalable, and manufacturable construction of a functional drug testing platform through the sustained maintenance of model cells.
Collapse
Affiliation(s)
- Liang Zhu
- Singapore Institute of Manufacturing Technology, Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, #08-04 Innovis, Singapore 138634, Singapore; (L.Z.); (H.X.)
- Mechanobiology Institute, National University of Singapore, T-Lab, #05-01, 5A Engineering Drive 1, Singapore 117411, Singapore;
- Institute of Biotechnology and Nanotechnology, Agency for Science, Technology and Research (A*STAR), The Nanos, #04-01, 31 Biopolis Way, Singapore 138669, Singapore
| | - Zhenfeng Wang
- Mechanobiology Institute, National University of Singapore, T-Lab, #05-01, 5A Engineering Drive 1, Singapore 117411, Singapore;
| | - Huanming Xia
- Singapore Institute of Manufacturing Technology, Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, #08-04 Innovis, Singapore 138634, Singapore; (L.Z.); (H.X.)
- School of Mechanical Engineering, Nanjing University of Science and Technology, 200 Xiaolingwei St., Nanjing 210094, China
| | - Hanry Yu
- Mechanobiology Institute, National University of Singapore, T-Lab, #05-01, 5A Engineering Drive 1, Singapore 117411, Singapore;
- Institute of Biotechnology and Nanotechnology, Agency for Science, Technology and Research (A*STAR), The Nanos, #04-01, 31 Biopolis Way, Singapore 138669, Singapore
- Department of Physiology, Yong Loo Lin School of Medicine, MD9-04-11, 2 Medical Drive, Singapore 117597, Singapore
- Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, #10-01 CREATE Tower, Singapore 138602, Singapore
- Correspondence:
| |
Collapse
|
26
|
Duivenvoorde LPM, Louisse J, Pinckaers NET, Nguyen T, van der Zande M. Comparison of gene expression and biotransformation activity of HepaRG cells under static and dynamic culture conditions. Sci Rep 2021; 11:10327. [PMID: 33990636 PMCID: PMC8121841 DOI: 10.1038/s41598-021-89710-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 04/27/2021] [Indexed: 11/08/2022] Open
Abstract
Flow conditions have been shown to be important in improving longevity and functionality of primary hepatocytes, but the impact of flow on HepaRG cells is largely unknown. We studied the expression of genes encoding CYP enzymes and transporter proteins and CYP1 and CYP3A4 activity during 8 weeks of culture in HepaRG cells cultured under static conditions (conventional 24-/96-well plate culture with common bicarbonate/CO2 buffering) and under flow conditions in an organ-on-chip (OOC) device. Since the OOC-device is a closed system, bicarbonate/CO2 buffering was not possible, requiring application of another buffering agent, such as HEPES. In order to disentangle the effects of HEPES from the effects of flow, we also applied HEPES-supplemented medium in static cultures and studied gene expression and CYP activity. We found that cells cultured under flow conditions in the OOC-device, as well as cells cultured under static conditions with HEPES-supplemented medium, showed more stable gene expression levels. Furthermore, only cells cultured in the OOC-device showed relatively high baseline CYP1 activity, and their gene expression levels of selected CYPs and transporters were most similar to gene expression levels in human primary hepatocytes. However, there was a decrease in baseline CYP3A4 activity under flow conditions compared to HepaRG cells cultured under static conditions. Altogether, the present study shows that HepaRG cells cultured in the OOC-device were more stable than in static cultures, being a promising in vitro model to study hepatoxicity of chemicals upon chronic exposure.
Collapse
Affiliation(s)
- Loes P M Duivenvoorde
- Wageningen Food Safety Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands.
| | - Jochem Louisse
- Wageningen Food Safety Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Nicole E T Pinckaers
- Wageningen Food Safety Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Tien Nguyen
- Wageningen Food Safety Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| | - Meike van der Zande
- Wageningen Food Safety Research, P.O. Box 230, 6700 AE, Wageningen, The Netherlands
| |
Collapse
|
27
|
Lee-Montiel FT, Laemmle A, Charwat V, Dumont L, Lee CS, Huebsch N, Okochi H, Hancock MJ, Siemons B, Boggess SC, Goswami I, Miller EW, Willenbring H, Healy KE. Integrated Isogenic Human Induced Pluripotent Stem Cell-Based Liver and Heart Microphysiological Systems Predict Unsafe Drug-Drug Interaction. Front Pharmacol 2021; 12:667010. [PMID: 34025426 PMCID: PMC8138446 DOI: 10.3389/fphar.2021.667010] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Accepted: 04/14/2021] [Indexed: 12/14/2022] Open
Abstract
Three-dimensional (3D) microphysiological systems (MPSs) mimicking human organ function in vitro are an emerging alternative to conventional monolayer cell culture and animal models for drug development. Human induced pluripotent stem cells (hiPSCs) have the potential to capture the diversity of human genetics and provide an unlimited supply of cells. Combining hiPSCs with microfluidics technology in MPSs offers new perspectives for drug development. Here, the integration of a newly developed liver MPS with a cardiac MPS—both created with the same hiPSC line—to study drug–drug interaction (DDI) is reported. As a prominent example of clinically relevant DDI, the interaction of the arrhythmogenic gastroprokinetic cisapride with the fungicide ketoconazole was investigated. As seen in patients, metabolic conversion of cisapride to non-arrhythmogenic norcisapride in the liver MPS by the cytochrome P450 enzyme CYP3A4 was inhibited by ketoconazole, leading to arrhythmia in the cardiac MPS. These results establish integration of hiPSC-based liver and cardiac MPSs to facilitate screening for DDI, and thus drug efficacy and toxicity, isogenic in the same genetic background.
Collapse
Affiliation(s)
- Felipe T Lee-Montiel
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Alexander Laemmle
- Department of Surgery, Division of Transplant Surgery, Liver Center and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, University of California San Francisco, San Francisco, CA, United States.,Institute of Clinical Chemistry and Department of Pediatrics, Inselspital, University Hospital Bern, Bern, Switzerland
| | - Verena Charwat
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Laure Dumont
- Department of Surgery, Division of Transplant Surgery, Liver Center and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, University of California San Francisco, San Francisco, CA, United States
| | - Caleb S Lee
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Nathaniel Huebsch
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Hideaki Okochi
- Department of Bioengineering and Therapeutic Sciences, Schools of Pharmacy and Medicine, University of California San Francisco, San Francisco, CA, United States
| | | | - Brian Siemons
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Steven C Boggess
- Department of Chemistry, University of California Berkeley, Berkeley, CA, United States
| | - Ishan Goswami
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| | - Evan W Miller
- Departments of Chemistry and Molecular & Cell Biology, and Helen Wills Neuroscience Institute, University of California Berkeley, Berkeley, CA, United States
| | - Holger Willenbring
- Department of Surgery, Division of Transplant Surgery, Liver Center and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, University of California San Francisco, San Francisco, CA, United States
| | - Kevin E Healy
- Departments of Bioengineering, and Materials Science & Engineering, University of California Berkeley, Berkeley, CA, United States
| |
Collapse
|
28
|
Clarke GA, Hartse BX, Niaraki Asli AE, Taghavimehr M, Hashemi N, Abbasi Shirsavar M, Montazami R, Alimoradi N, Nasirian V, Ouedraogo LJ, Hashemi NN. Advancement of Sensor Integrated Organ-on-Chip Devices. SENSORS (BASEL, SWITZERLAND) 2021; 21:1367. [PMID: 33671996 PMCID: PMC7922590 DOI: 10.3390/s21041367] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 02/10/2021] [Accepted: 02/11/2021] [Indexed: 02/06/2023]
Abstract
Organ-on-chip devices have provided the pharmaceutical and tissue engineering worlds much hope since they arrived and began to grow in sophistication. However, limitations for their applicability were soon realized as they lacked real-time monitoring and sensing capabilities. The users of these devices relied solely on endpoint analysis for the results of their tests, which created a chasm in the understanding of life between the lab the natural world. However, this gap is being bridged with sensors that are integrated into organ-on-chip devices. This review goes in-depth on different sensing methods, giving examples for various research on mechanical, electrical resistance, and bead-based sensors, and the prospects of each. Furthermore, the review covers works conducted that use specific sensors for oxygen, and various metabolites to characterize cellular behavior and response in real-time. Together, the outline of these works gives a thorough analysis of the design methodology and sophistication of the current sensor integrated organ-on-chips.
Collapse
Affiliation(s)
- Gabriel A. Clarke
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Brenna X. Hartse
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Amir Ehsan Niaraki Asli
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Mehrnoosh Taghavimehr
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Niloofar Hashemi
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 11365, Iran;
| | - Mehran Abbasi Shirsavar
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Reza Montazami
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Nima Alimoradi
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Vahid Nasirian
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Lionel J. Ouedraogo
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
| | - Nicole N. Hashemi
- Department of Mechanical Engineering, Iowa State University, Ames, IA 50011, USA; (G.A.C.); (B.X.H.); (A.E.N.A.); (M.T.); (M.A.S.); (R.M.); (N.A.); (V.N.); (L.J.O.)
- Department of Biomedical Sciences, Iowa State University, Ames, IA 50011, USA
| |
Collapse
|
29
|
Kühnl J, Tao TP, Brandmair K, Gerlach S, Rings T, Müller-Vieira U, Przibilla J, Genies C, Jaques-Jamin C, Schepky A, Marx U, Hewitt NJ, Maschmeyer I. Characterization of application scenario-dependent pharmacokinetics and pharmacodynamic properties of permethrin and hyperforin in a dynamic skin and liver multi-organ-chip model. Toxicology 2020; 448:152637. [PMID: 33220337 DOI: 10.1016/j.tox.2020.152637] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 11/11/2020] [Accepted: 11/12/2020] [Indexed: 12/12/2022]
Abstract
Microphysiological systems (MPS) aim to mimic the dynamic microenvironment and the interaction between tissues. While MPS exist for investigating pharmaceuticals, the applicability of MPS for cosmetics ingredients is yet to be evaluated. The HUMIMIC Chip2 ("Chip2″), is the first multi-organ chip technology to incorporate skin models, allowing for the topical route to be tested. Therefore, we have used this model to analyze the impact of different exposure scenarios on the pharmacokinetics and pharmacodynamics of two topically exposed chemicals, hyperforin and permethrin. The Chip2 incorporated reconstructed human epidermis models (EpiDerm™) and HepaRG-stellate spheroids. Initial experiments using static incubations of single organoids helped determine the optimal dose. In the Chip2 studies, parent and metabolites were analyzed in the circuit over 5 days after application of single and repeated topical or systemic doses. The gene expression of relevant xenobiotic metabolizing enzymes in liver spheroids was measured to reflect toxicodynamics effects of the compounds in liver. The results show that 1) metabolic capacities of EpiDerm™ and liver spheroids were maintained over five days; 2) EpiDerm™ model barrier function remained intact; 3) repeated application of compounds resulted in higher concentrations of parent chemicals and most metabolites compared to single application; 4) compound-specific gene induction e.g. induction of CYP3A4 by hyperforin depended on the application route and frequency; 5) different routes of application influenced the systemic concentrations of both parents and metabolites in the chip over the course of the experiment; 6) there was excellent intra- and inter-lab reproducibility. For permethrin, a process similar to the excretion in a human in vivo study could be simulated which was remarkably comparable to the in vivo situation. These results support the use of the Chip2 model to provide information on parent and metabolite disposition that may be relevant to risk assessment of topically applied cosmetics ingredients.
Collapse
Affiliation(s)
- Jochen Kühnl
- Beiersdorf AG, Unnastraße 48, D-20253, Hamburg, Germany.
| | - Thi Phuong Tao
- TissUse GmbH, Oudenarder Str. 16, D-13347, Berlin, Germany
| | | | - Silke Gerlach
- Beiersdorf AG, Unnastraße 48, D-20253, Hamburg, Germany
| | - Thamée Rings
- Beiersdorf AG, Unnastraße 48, D-20253, Hamburg, Germany
| | | | - Julia Przibilla
- Pharmacelsus GmbH, Science Park 2, D-66123, Saarbrücken, Germany
| | | | | | | | - Uwe Marx
- TissUse GmbH, Oudenarder Str. 16, D-13347, Berlin, Germany
| | - Nicola J Hewitt
- Cosmetics Europe, Avenue Herrmann-Debroux 40, 1160, Auderghem, Belgium
| | | |
Collapse
|
30
|
Huang D, Gibeley SB, Xu C, Xiao Y, Celik O, Ginsberg HN, Leong KW. Engineering liver microtissues for disease modeling and regenerative medicine. ADVANCED FUNCTIONAL MATERIALS 2020; 30:1909553. [PMID: 33390875 PMCID: PMC7774671 DOI: 10.1002/adfm.201909553] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Indexed: 05/08/2023]
Abstract
The burden of liver diseases is increasing worldwide, accounting for two million deaths annually. In the past decade, tremendous progress has been made in the basic and translational research of liver tissue engineering. Liver microtissues are small, three-dimensional hepatocyte cultures that recapitulate liver physiology and have been used in biomedical research and regenerative medicine. This review summarizes recent advances, challenges, and future directions in liver microtissue research. Cellular engineering approaches are used to sustain primary hepatocytes or produce hepatocytes derived from pluripotent stem cells and other adult tissues. Three-dimensional microtissues are generated by scaffold-free assembly or scaffold-assisted methods such as macroencapsulation, droplet microfluidics, and bioprinting. Optimization of the hepatic microenvironment entails incorporating the appropriate cell composition for enhanced cell-cell interactions and niche-specific signals, and creating scaffolds with desired chemical, mechanical and physical properties. Perfusion-based culture systems such as bioreactors and microfluidic systems are used to achieve efficient exchange of nutrients and soluble factors. Taken together, systematic optimization of liver microtissues is a multidisciplinary effort focused on creating liver cultures and on-chip models with greater structural complexity and physiological relevance for use in liver disease research, therapeutic development, and regenerative medicine.
Collapse
Affiliation(s)
- Dantong Huang
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Sarah B. Gibeley
- Institute of Human Nutrition, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Cong Xu
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Yang Xiao
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Ozgenur Celik
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Henry N. Ginsberg
- Department of Medicine, Columbia University Irving Medical Center, New York, NY 10032, USA
| | - Kam W. Leong
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
- Department of Systems Biology, Columbia University Irving Medical Center, New York, NY 10032, USA
| |
Collapse
|
31
|
Moradi E, Jalili-Firoozinezhad S, Solati-Hashjin M. Microfluidic organ-on-a-chip models of human liver tissue. Acta Biomater 2020; 116:67-83. [PMID: 32890749 DOI: 10.1016/j.actbio.2020.08.041] [Citation(s) in RCA: 94] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 08/22/2020] [Accepted: 08/27/2020] [Indexed: 02/08/2023]
Abstract
The liver is the largest internal organ of the body with complex microarchitecture and function that plays critical roles in drug metabolism. Hepatotoxicity and drug-induced liver injury (DILI) caused by various drugs is the main reason for late-stage drug failures. Moreover, liver diseases are among the leading causes of death in the world, with the number of new cases arising each year. Although animal models have been used to understand human drug metabolism and toxicity before clinical trials, tridimensional microphysiological systems, such as liver-on-a-chip (Liver Chip) platforms, could better recapitulate features of human liver physiology and pathophysiology and thus, are often more predictive of human outcome. Liver Chip devices have shown promising results in mimicking in vivo condition by recapitulating the sinusoidal structure of the liver, maintaining high cell viability and cellular phenotypes, and emulating native liver functions. Here, we first review the cellular constituents and physiology of the liver and then critically discuss the state-of-the-art chip-based liver models and their applications in drug screening, disease modeling, and regenerative medicine. We finally address the pending issues of existing platforms and touch upon future directions for developing new, advanced on-chip models.
Collapse
Affiliation(s)
- Ehsanollah Moradi
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Iran
| | - Sasan Jalili-Firoozinezhad
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| | - Mehran Solati-Hashjin
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Iran.
| |
Collapse
|
32
|
Meng Q, Wang Y, Li Y, Shen C. Hydrogel microfluidic-based liver-on-a-chip: Mimicking the mass transfer and structural features of liver. Biotechnol Bioeng 2020; 118:612-621. [PMID: 33017042 DOI: 10.1002/bit.27589] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Revised: 09/25/2020] [Accepted: 09/28/2020] [Indexed: 01/10/2023]
Abstract
Liver is fed by nutrition via diffusion across the vascular wall from blood flow. However, hepatocytes in liver models are directly exposed to the perfusion culture medium, where the shear stress reduces the cell viability and liver-specific functions. By mimicking the mass transfer and structural features of hepatic lobule, we designed a microfluidic liver-on-a-chip based on the di-acrylated pluronic F127 hydrogel. In the hydrogel chip, hepatocellular carcinoma HepG2 and human hepatic stellate cell LX-2 were statically cultured inside the microwells on the outer channel. These hepatic cells were fed by the diffused medium from the adjacent but separated inner channel with endothelial cell monolayers, which was perfused by the medium with physiologically relevant shear stress. As found, the hepatic cells in the liver-on-a-chip rapidly formed spheroids within 1-day incubation and expressed about one to two-fold higher viability/liver-specific functions than the corresponding static culture for at least 8 days. Moreover, the presence of endothelial cells also contributed to the expression of liver-specific functions in the liver-on-a-chip. Therefore, the proposed liver-on-a-chip provides a new concept for construction of 3D liver models in vitro, and shows the potential value for a variety of applications including bio-artificial livers and drug toxicity screening.
Collapse
Affiliation(s)
- Qin Meng
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, Zhejiang, China
| | - Ying Wang
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, Zhejiang, China
| | - Yingjun Li
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, Zhejiang, China
| | - Chong Shen
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, Zhejiang, China
| |
Collapse
|
33
|
Oleaga C, Bridges LR, Persaud K, McAleer CW, Long CJ, Hickman JJ. A functional long-term 2D serum-free human hepatic in vitro system for drug evaluation. Biotechnol Prog 2020; 37:e3069. [PMID: 32829524 DOI: 10.1002/btpr.3069] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 08/13/2020] [Accepted: 08/20/2020] [Indexed: 01/05/2023]
Abstract
Human in vitro hepatic models generate faster drug toxicity data with higher human predictability compared to animal models. However, for long-term studies, current models require the use of serum and 3D architecture, limiting their utility. Maintaining a functional long-term human in vitro hepatic culture that avoids complex structures and serum would improve the value of such systems for preclinical studies. This would also enable a more straightforward integration with current multi-organ devices to study human systemic toxicity to generate an alternative model to chronic animal evaluations. A human primary hepatocyte culture system was characterized for 28 days in 2D and serum-free defined conditions. Under the studied conditions, human primary hepatocytes maintained their characteristic morphology, hepatic markers and functions for 28 days. The acute and chronic administration of known drugs validated the sensitivity of the system for drug testing. This human 2D model represents a realistic system to evaluate hepatic function for long-term drug studies, without the need of animal serum, confounding variable in most models, and with less complexity and resultant cost compared to most 3D models. The defined culture conditions can easily be integrated into complex multi-organ in vitro models for studying systemic effects driven by the liver function for long-term evaluations.
Collapse
Affiliation(s)
- Carlota Oleaga
- NanoScience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - L Richard Bridges
- NanoScience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - Keisha Persaud
- NanoScience Technology Center, University of Central Florida, Orlando, Florida, USA
| | | | - Christopher J Long
- NanoScience Technology Center, University of Central Florida, Orlando, Florida, USA
| | - James J Hickman
- NanoScience Technology Center, University of Central Florida, Orlando, Florida, USA
| |
Collapse
|
34
|
Jayaprakash V, Costalonga M, Dhulipala S, Varanasi KK. Enhancing the Injectability of High Concentration Drug Formulations Using Core Annular Flows. Adv Healthc Mater 2020; 9:e2001022. [PMID: 32830449 DOI: 10.1002/adhm.202001022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Indexed: 01/01/2023]
Abstract
Highly concentrated biological drug formulations would offer tremendous benefits to global health, yet they cannot be manually injected using commercial syringes and needles due to their high viscosities. Current approaches to address this problem face several challenges such as crosscontamination, high cost, needle clogging, and protein inactivation. This work reports a simple method to enhance formulation injectability using a core annular flow, where the transport of highly viscous fluids through a needle is enabled by coaxial lubrication by a less viscous fluid. A phase diagram to ensure optimally lubricated flow while minimizing the volume fraction of lubricant injected is established. The technique presented here allows for up to a 7x reduction in injection force for the highest viscosity ratio tested. The role of buoyancy-driven eccentricity in governing nominal pressure reduction is also examined. Finally, the findings are implemented into the development of a double barreled syringe that significantly expands the range of injectable concentrations of several biologic formulations.
Collapse
Affiliation(s)
- Vishnu Jayaprakash
- Department of Mechanical Engineering Massachusetts Institute of Technology 77 Massachusetts Ave Cambridge MA 02139 USA
| | - Maxime Costalonga
- Department of Mechanical Engineering Massachusetts Institute of Technology 77 Massachusetts Ave Cambridge MA 02139 USA
| | - Somayajulu Dhulipala
- Department of Mechanical Engineering Massachusetts Institute of Technology 77 Massachusetts Ave Cambridge MA 02139 USA
| | - Kripa K. Varanasi
- Department of Mechanical Engineering Massachusetts Institute of Technology 77 Massachusetts Ave Cambridge MA 02139 USA
| |
Collapse
|
35
|
Ehrlich A, Duche D, Ouedraogo G, Nahmias Y. Challenges and Opportunities in the Design of Liver-on-Chip Microdevices. Annu Rev Biomed Eng 2020; 21:219-239. [PMID: 31167098 DOI: 10.1146/annurev-bioeng-060418-052305] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The liver is the central hub of xenobiotic metabolism and consequently the organ most prone to cosmetic- and drug-induced toxicity. Failure to detect liver toxicity or to assess compound clearance during product development is a major cause of postmarketing product withdrawal, with disastrous clinical and financial consequences. While small animals are still the preferred model in drug development, the recent ban on animal use in the European Union created a pressing need to develop precise and efficient tools to detect human liver toxicity during cosmetic development. This article includes a brief review of liver development, organization, and function and focuses on the state of the art of long-term cell culture, including hepatocyte cell sources, heterotypic cell-cell interactions, oxygen demands, and culture medium formulation. Finally, the article reviews emerging liver-on-chip devices and discusses the advantages and pitfalls of individual designs. The goal of this review is to provide a framework to design liver-on-chip devices and criteria with which to evaluate this emerging technology.
Collapse
Affiliation(s)
- Avner Ehrlich
- Grass Center for Bioengineering, Benin School of Computer Science and Engineering, Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - Daniel Duche
- L'Oréal Research and Innovation, Aulnay-sous-Bois 93600, France
| | | | - Yaakov Nahmias
- Grass Center for Bioengineering, Benin School of Computer Science and Engineering, Hebrew University of Jerusalem, Jerusalem 91904, Israel.,Department of Cell and Developmental Biology, Silberman Institute of Life Sciences, Hebrew University of Jerusalem, Jerusalem 91904, Israel.,Tissue Dynamics Ltd., Jerusalem 91904, Israel
| |
Collapse
|
36
|
Nikmaneshi MR, Firoozabadi B, Munn LL. A mechanobiological mathematical model of liver metabolism. Biotechnol Bioeng 2020; 117:2861-2874. [PMID: 32501531 DOI: 10.1002/bit.27451] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 05/30/2020] [Accepted: 06/04/2020] [Indexed: 02/01/2023]
Abstract
The liver plays a complex role in metabolism and detoxification, and better tools are needed to understand its function and to develop liver-targeted therapies. In this study, we establish a mechanobiological model of liver transport and hepatocyte biology to elucidate the metabolism of urea and albumin, the production/detoxification of ammonia, and consumption of oxygen and nutrients. Since hepatocellular shear stress (SS) can influence the enzymatic activities of liver, the effect of SS on the urea and albumin synthesis are empirically modeled through the mechanotransduction mechanisms. The results demonstrate that the rheology and dynamics of the sinusoid flow can significantly affect liver metabolism. We show that perfusate rheology and blood hematocrit can affect urea and albumin production by changing hepatocyte mechanosensitive metabolism. The model can also simulate enzymatic diseases of the liver such as hyperammonemia I, hyperammonemia II, hyperarginemia, citrollinemia, and argininosuccinicaciduria, which disrupt the urea metabolism and ammonia detoxification. The model is also able to predict how aggregate cultures of hepatocytes differ from single cell cultures. We conclude that in vitro perfusable devices for the study of liver metabolism or personalized medicine should be designed with similar morphology and fluid dynamics as patient liver tissue. This robust model can be adapted to any type of hepatocyte culture to determine how hepatocyte viability, functionality, and metabolism are influenced by liver pathologies and environmental conditions.
Collapse
Affiliation(s)
- Mohammad R Nikmaneshi
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.,Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Bahar Firoozabadi
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Lance L Munn
- Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
37
|
Danoy M, Poulain S, Lereau-Bernier M, Kato S, Scheidecker B, Kido T, Miyajima A, Sakai Y, Plessy C, Leclerc E. Characterization of liver zonation-like transcriptomic patterns in HLCs derived from hiPSCs in a microfluidic biochip environment. Biotechnol Prog 2020; 36:e3013. [PMID: 32364651 DOI: 10.1002/btpr.3013] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 04/20/2020] [Accepted: 04/28/2020] [Indexed: 12/17/2022]
Abstract
The liver zonation is an important phenomenon characterized by a gradient of several functions along the liver acinus. However, this gradient remains difficult to reproduce in in-vitro conditions, making the obtention of an in-vitro method to recapitulate the liver zonation a challenging issue. In this study, we evaluated the spatial evolution of the transcriptome profile of human induced pluripotent stem cells (hiPSCs) differentiated toward hepatocytes-like cells (HLCs) phenotype in a microfluidic biochip environment. Cells collected at the inlet of the biochip, where the oxygen concentration is higher, were identified by the expression of genes involved in metabolic pathways related to cellular reorganization and cell proliferation. Cells collected in the middle and at the outlet of the biochips, where oxygen concentrations are lower, were characterized by the upregulation of genes involved in cellular detoxification processes (CYP450), PPAR signaling or arginine biosynthesis. A subset of 16 transcription factors (TFs) was extracted and identified as upstream regulators to HNF1A and PPARA. These TFs are also known as regulators to target genes engaged in the Wnt/βcatenin pathway, in the TGFβ/BMP/SMAD signaling, in the transition between epithelial mesenchymal transition (EMT) and mesenchymal epithelial transition (MET), in the homeostasis of lipids, bile acids and carbohydrates homeostasis, in drug metabolism, in the estrogen processing and in the oxidative stress response. Overall, the analysis allowed to confirm a partial zonation-like pattern in hiPSCs-derived HLCs in the microfluidic biochip environment. These results provide important insights into the reproduction of liver zonation in-vitro for a better understanding of the phenomenon.
Collapse
Affiliation(s)
- Mathieu Danoy
- CNRS UMI 2820, Laboratory for Integrated Micro Mechatronic Systems, Institute of Industrial Science, University of Tokyo, Tokyo, Japan
| | - Stéphane Poulain
- RIKEN Center for Integrative Medical Sciences, Division of Genomic Medicine, Yokohama, Kanagawa, Japan
| | - Myriam Lereau-Bernier
- CNRS UMI 2820, Laboratory for Integrated Micro Mechatronic Systems, Institute of Industrial Science, University of Tokyo, Tokyo, Japan
| | - Sachi Kato
- RIKEN Center for Integrative Medical Sciences, Division of Genomic Medicine, Yokohama, Kanagawa, Japan
| | - Benedikt Scheidecker
- Department of Chemical System Engineering, graduate school of Engineering, The University of Tokyo, Tokyo, Japan
| | - Taketomo Kido
- Laboratory of Stem Cell Therapy, Institute for Quantitative Biosciences, The University of Tokyo, Tokyo, Japan
| | - Atsushi Miyajima
- Laboratory of Stem Cell Therapy, Institute for Quantitative Biosciences, The University of Tokyo, Tokyo, Japan
| | - Yasuyuki Sakai
- Department of Chemical System Engineering, graduate school of Engineering, The University of Tokyo, Tokyo, Japan
| | - Charles Plessy
- RIKEN Center for Integrative Medical Sciences, Division of Genomic Medicine, Yokohama, Kanagawa, Japan
| | - Eric Leclerc
- CNRS UMI 2820, Laboratory for Integrated Micro Mechatronic Systems, Institute of Industrial Science, University of Tokyo, Tokyo, Japan
| |
Collapse
|
38
|
Liver Bioreactor Design Issues of Fluid Flow and Zonation, Fibrosis, and Mechanics: A Computational Perspective. J Funct Biomater 2020; 11:jfb11010013. [PMID: 32121053 PMCID: PMC7151609 DOI: 10.3390/jfb11010013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 01/27/2020] [Accepted: 02/18/2020] [Indexed: 02/06/2023] Open
Abstract
Tissue engineering, with the goal of repairing or replacing damaged tissue and organs, has continued to make dramatic science-based advances since its origins in the late 1980’s and early 1990’s. Such advances are always multi-disciplinary in nature, from basic biology and chemistry through physics and mathematics to various engineering and computer fields. This review will focus its attention on two topics critical for tissue engineering liver development: (a) fluid flow, zonation, and drug screening, and (b) biomechanics, tissue stiffness, and fibrosis, all within the context of 3D structures. First, a general overview of various bioreactor designs developed to investigate fluid transport and tissue biomechanics is given. This includes a mention of computational fluid dynamic methods used to optimize and validate these designs. Thereafter, the perspective provided by computer simulations of flow, reactive transport, and biomechanics responses at the scale of the liver lobule and liver tissue is outlined, in addition to how bioreactor-measured properties can be utilized in these models. Here, the fundamental issues of tortuosity and upscaling are highlighted, as well as the role of disease and fibrosis in these issues. Some idealized simulations of the effects of fibrosis on lobule drug transport and mechanics responses are provided to further illustrate these concepts. This review concludes with an outline of some practical applications of tissue engineering advances and how efficient computational upscaling techniques, such as dual continuum modeling, might be used to quantify the transition of bioreactor results to the full liver scale.
Collapse
|
39
|
Rimington RP, Capel AJ, Chaplin KF, Fleming JW, Bandulasena HCH, Bibb RJ, Christie SDR, Lewis MP. Differentiation of Bioengineered Skeletal Muscle within a 3D Printed Perfusion Bioreactor Reduces Atrophic and Inflammatory Gene Expression. ACS Biomater Sci Eng 2019; 5:5525-5538. [PMID: 33464072 DOI: 10.1021/acsbiomaterials.9b00975] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Bioengineered skeletal muscle tissues benefit from dynamic culture environments which facilitate the appropriate provision of nutrients and removal of cellular waste products. Biologically compatible perfusion systems hold the potential to enhance the physiological biomimicry of in vitro tissues via dynamic culture, in addition to providing technological advances in analytical testing and live cellular imaging for analysis of cellular development. To meet such diverse requirements, perfusion systems require the capacity and adaptability to incorporate multiple cell laden constructs of both monolayer and bioengineered tissues. This work reports perfusion systems produced using additive manufacturing technology for the in situ phenotypic development of myogenic precursor cells in monolayer and bioengineered tissue. Biocompatibility of systems 3D printed using stereolithography (SL), laser sintering (LS), and PolyJet outlined preferential morphological development within both SL and LS devices. When exposed to intermittent perfusion in the monolayer, delayed yet physiologically representative cellular proliferation, MyoD and myogenin transcription of C2C12 cells was evident. Long-term (8 days) intermittent perfusion of monolayer cultures outlined viable morphological and genetic in situ differentiation for the live cellular imaging of myogenic development. Continuous perfusion cultures (13 days) of bioengineered skeletal muscle tissues outlined in situ myogenic differentiation, forming mature multinucleated myotubes. Here, reductions in IL-1β and TNF-α inflammatory cytokines, myostatin, and MuRF-1 atrophic mRNA expression were observed. Comparable myosin heavy chain (MyHC) isoform transcription profiles were evident between conditions; however, total mRNA expression was reduced in perfusion conditions. Decreased transcription of MuRF1 and subsequent reduced ubiquitination of the MyHC protein allude to a decreased requirement for transcription of MyHC isoform transcripts. Together, these data appear to indicate that 3D printed perfusion systems elicit enhanced stability of the culture environment, resulting in a reduced basal requirement for MyHC gene expression within bioengineered skeletal muscle tissue.
Collapse
|
40
|
Sharifi F, Firoozabadi B, Firoozbakhsh K. Numerical Investigations of Hepatic Spheroids Metabolic Reactions in a Perfusion Bioreactor. Front Bioeng Biotechnol 2019; 7:221. [PMID: 31572719 PMCID: PMC6751279 DOI: 10.3389/fbioe.2019.00221] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 08/28/2019] [Indexed: 12/20/2022] Open
Abstract
Miniaturized culture systems of hepatic cells are emerging as a strong tool facilitating studies related to liver diseases and drug discovery. However, the experimental optimization of various parameters involved in the operation of these systems is time-consuming and expensive. Hence, developing numerical tools predicting the function of such systems can significantly reduce the associated cost. In this paper, a perfusion-based three dimensional (3D) bioreactor comprising encapsulated human liver hepatocellular carcinoma (HepG2) spheroids are analyzed. The flow and mass transfer equations for oxygen as well as different metabolites such as albumin, glucose, glutamine, ammonia, and urea were solved in three different domains, i.e., free flow, hydrogel, and spheroid porous media sections. Since the spheroids were encapsulated inside the hydrogel, shear stress imposed on them were found to be less than tolerable thresholds. The predicted cumulative albumin concentration over the 7 days of culture period showed a good agreement with the experimental data. Based on the critical role of oxygen supply to the hepatocytes, a parametric study was performed and the effect of various parameters was investigated. Results illustrated that convection mechanism was the dominant transport mechanism in the main-stream section contrary to the intra spheroids parts where the diffusion was the prevailing transport mechanism. In the hydrogel parts, the rate of diffusion and convection mechanisms were almost identical. As expected, higher perfusion rate would provide high oxygen level for the cells and, smaller spheroids with a diameter of 100 μm were at the low risk of hypoxic conditions due to short diffusive oxygen penetration depth. Numerical results evidenced that spheroids with diameter size >200 μm at low porosities (ε = 0.2-0.3) were at risk of oxygen depletion, especially at locations near the core center. Therefore, these results could be beneficial in preventing hypoxic conditions during in vitro experiments. The presented numerical model provides a numerical platform which can help researchers to design and optimize complex bioreactors and obtain numerical indexes of the main metabolites in a very short time prior to any fabrications. Such numerical indexes can be helpful in certifying the outcomes of forensic investigations.
Collapse
Affiliation(s)
| | - Bahar Firoozabadi
- School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | | |
Collapse
|
41
|
Matsumoto S, Safitri AR, Danoy M, Maekawa T, Kinoshita H, Shinohara M, Sakai Y, Fujii T, Leclerc E. Investigation of the hepatic respiration and liver zonation on rat hepatocytes using an integrated oxygen biosensor in a microscale device. Biotechnol Prog 2019; 35:e2854. [PMID: 31131557 DOI: 10.1002/btpr.2854] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 01/08/2019] [Accepted: 05/15/2019] [Indexed: 02/06/2023]
Abstract
The development of an in vitro functional liver zonation model is a major issue to reproduce physiological liver features. Oxygen concentration is one of the potential explanations of a primary regulating factor of zonation. In this frame, we investigated the oxygen gradient inside a microfluidic device containing rat hepatocyte cultures. The device integrated a platinum (Pt) (II) octaethylporphyrin sensor, allowing a 2D mapping of the oxygen concentration. After 3 hr adhesion of the hepatocytes, the sensor indicated an intense oxygen depletion, leading to an oxygen shortage in the center of the device. After a 30 min perfusion of the culture medium, we monitored the formation of the oxygen gradient along the culture due to cellular respiration. The profile of the oxygen gradient was modulated and controlled by increasing either the perfusion flow rate or the device thickness. In addition, the oxygen gradient was time dependent as far as it decreased with the time of culture. Perivenous and periportal liver patterns were characterized by the immunostaining of the hepatic markers. We put in evidence a spatio temporal hepatic organization. We observed the overexpression since 24 hr of perfusion of the APC and PCK1 proteins upstream in the oxygen-rich area of the device. The overexpression of GS, GCK, CYP1A, and HIFα proteins were observed downstream in the oxygen-poor area. Then, CYP3A2 and β-catenin spatial reorganization was achieved after 48 hr of culture. The results presented a partial zonation-like pattern that was superimposed with an oxygen gradient profile.
Collapse
Affiliation(s)
- Satomi Matsumoto
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Applied Microfluidic Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Astia R Safitri
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Organ Biosystem Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Mathieu Danoy
- Organ Biosystem Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- LIMMS/CNRS-IIS (UMI 2820), Laboratory for Integrated Micro-Mechatronic Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Toshiro Maekawa
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Applied Microfluidic Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Haruyuki Kinoshita
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Applied Microfluidic Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Marie Shinohara
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Organ Biosystem Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Yasuyuki Sakai
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Organ Biosystem Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Teruo Fujii
- CIBiS, Center for International Research on Integrative Biomedical Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- Applied Microfluidic Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| | - Eric Leclerc
- Organ Biosystem Laboratory, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
- LIMMS/CNRS-IIS (UMI 2820), Laboratory for Integrated Micro-Mechatronic Systems, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
42
|
Agarwal T, Subramanian B, Maiti TK. Liver Tissue Engineering: Challenges and Opportunities. ACS Biomater Sci Eng 2019; 5:4167-4182. [PMID: 33417776 DOI: 10.1021/acsbiomaterials.9b00745] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Liver tissue engineering aims at the possibility of reproducing a fully functional organ for the treatment of acute and chronic liver disorders. Approaches in this field endeavor to replace organ transplantation (gold standard treatment for liver diseases in a clinical setting) with in vitro developed liver tissue constructs. However, the complexity of the liver microarchitecture and functionality along with the limited supply of cellular components of the liver pose numerous challenges. This review provides a comprehensive outlook onto how the physicochemical, mechanobiological, and spatiotemporal aspects of the substrates could be tuned to address current challenges in the field. We also highlight the strategic advancements made in the field so far for the development of artificial liver tissue. We further showcase the currently available prototypes in research and clinical trials, which shows the hope for the future of liver tissue engineering.
Collapse
|
43
|
Young AT, Rivera KR, Erb PD, Daniele MA. Monitoring of Microphysiological Systems: Integrating Sensors and Real-Time Data Analysis toward Autonomous Decision-Making. ACS Sens 2019; 4:1454-1464. [PMID: 30964652 DOI: 10.1021/acssensors.8b01549] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Microphysiological systems replicate human organ function and are promising technologies for discovery of translatable biomarkers, pharmaceuticals, and regenerative therapies. Because microphysiological systems require complex microscale anatomical structures and heterogeneous cell populations, a major challenge remains to manufacture and operate these products with reproducible and standardized function. In this Perspective, three stages of microphysiological system monitoring, including process, development, and function, are assessed. The unique features and remaining technical challenges for the required sensors are discussed. Monitoring of microphysiological systems requires nondestructive, continuous biosensors and imaging techniques. With such tools, the extent of cellular and tissue development, as well as function, can be autonomously determined and optimized by correlating physical and chemical sensor outputs with markers of physiological performance. Ultimately, data fusion and analyses across process, development, and function monitors can be implemented to adopt microphysiological systems for broad research and commercial applications.
Collapse
Affiliation(s)
- Ashlyn T. Young
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Drive, Raleigh, North Carolina 27695, United States
| | - Kristina R. Rivera
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Drive, Raleigh, North Carolina 27695, United States
| | - Patrick D. Erb
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Drive, Raleigh, North Carolina 27695, United States
| | - Michael A. Daniele
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina, Chapel Hill, 911 Oval Drive, Raleigh, North Carolina 27695, United States
- Department of Electrical & Computer Engineering, North Carolina State University, 890 Oval Drive, Raleigh, North Carolina 27695, United States
| |
Collapse
|
44
|
Guo Z, Song J, Hao J, Zhao H, Du X, Li E, Kuang Y, Yang F, Wang W, Deng J, Wang Q. M2 macrophages promote NSCLC metastasis by upregulating CRYAB. Cell Death Dis 2019; 10:377. [PMID: 31097690 PMCID: PMC6522541 DOI: 10.1038/s41419-019-1618-x] [Citation(s) in RCA: 80] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 04/28/2019] [Accepted: 04/30/2019] [Indexed: 02/05/2023]
Abstract
The mechanism by which tumor-associated macrophages (TAMs) affect cancer progression is not fully understood. This study developed a microfluidic-based co-culture device to mimic the tumor microenvironment to assess TAM effects on invasion and metastasis in NSCLC. The results showed lung carcinoma cells could cause macrophages to show the M2 (a TAM-like) phenotype, and these M2 macrophages promoted lung cancer cell EMT and invasion. Proteomic analysis by the iTRAQ quantitation strategy and GO ontology of the cancer cells indicated that αB-Crystallin (CRYAB) might be involved in this process. Further, we confirmed the role of CRYAB in cancer invasion and metastasis through cell and animal experiments, as well as human cancer tissue assessment. Overall, we demonstrated that M2 macrophages promote malignancy in lung cancer through the EMT by upregulating CRYAB expression and activating the ERK1/2/Fra-1/slug signaling pathway.
Collapse
Affiliation(s)
- Zhe Guo
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China
- Department of Respiratory Medicine, The First Affiliated Hospital of Shantou University Medical College, Shantou, China
| | - Jing Song
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China
| | - Junxia Hao
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China
| | - Hui Zhao
- Department of Physical Examination Center, The Second Hospital, Dalian Medical University, Dalian, China
| | - Xiaohui Du
- Department of Scientific Research Center, The Second Hospital, Dalian Medical University, Dalian, China
| | - Encheng Li
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China
| | - Yanbin Kuang
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China
| | - Fuquan Yang
- Laboratory of Protein and Peptide Pharmaceuticals and Laboratory of Proteomics, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
| | - Wei Wang
- Institute of Microelectronics, Peking University, Beijing, China.
| | - Jiong Deng
- Translation Medicine Center, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.
| | - Qi Wang
- Department of Respiratory Medicine, The Second Hospital, Dalian Medical University, Dalian, China.
| |
Collapse
|
45
|
Varma S, Voldman J. Caring for cells in microsystems: principles and practices of cell-safe device design and operation. LAB ON A CHIP 2018; 18:3333-3352. [PMID: 30324208 PMCID: PMC6254237 DOI: 10.1039/c8lc00746b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Microfluidic device designers and users continually question whether cells are 'happy' in a given microsystem or whether they are perturbed by micro-scale technologies. This issue is normally brought up by engineers building platforms, or by external reviewers (academic or commercial) comparing multiple technological approaches to a problem. Microsystems can apply combinations of biophysical and biochemical stimuli that, although essential to device operation, may damage cells in complex ways. However, assays to assess the impact of microsystems upon cells have been challenging to conduct and have led to subjective interpretation and evaluation of cell stressors, hampering development and adoption of microsystems. To this end, we introduce a framework that defines cell health, describes how device stimuli may stress cells, and contrasts approaches to measure cell stress. Importantly, we provide practical guidelines regarding device design and operation to minimize cell stress, and recommend a minimal set of quantitative assays that will enable standardization in the assessment of cell health in diverse devices. We anticipate that as microsystem designers, reviewers, and end-users enforce such guidelines, we as a community can create a set of essential principles that will further the adoption of such technologies in clinical, translational and commercial applications.
Collapse
Affiliation(s)
- Sarvesh Varma
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| | - Joel Voldman
- Department of Electrical Engineering and Computer Science
, Massachusetts Institute of Technology
,
77 Massachusetts Avenue, Room 36-824
, Cambridge
, USA
.
; Fax: +617 258 5846
; Tel: +617 253 1583
| |
Collapse
|
46
|
In vitro and ex vivo systems at the forefront of infection modeling and drug discovery. Biomaterials 2018; 198:228-249. [PMID: 30384974 PMCID: PMC7172914 DOI: 10.1016/j.biomaterials.2018.10.030] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Revised: 10/05/2018] [Accepted: 10/23/2018] [Indexed: 12/11/2022]
Abstract
Bacterial infections and antibiotic resistant bacteria have become a growing problem over the past decade. As a result, the Centers for Disease Control predict more deaths resulting from microorganisms than all cancers combined by 2050. Currently, many traditional models used to study bacterial infections fail to precisely replicate the in vivo bacterial environment. These models often fail to incorporate fluid flow, bio-mechanical cues, intercellular interactions, host-bacteria interactions, and even the simple inclusion of relevant physiological proteins in culture media. As a result of these inadequate models, there is often a poor correlation between in vitro and in vivo assays, limiting therapeutic potential. Thus, the urgency to establish in vitro and ex vivo systems to investigate the mechanisms underlying bacterial infections and to discover new-age therapeutics against bacterial infections is dire. In this review, we present an update of current in vitro and ex vivo models that are comprehensively changing the landscape of traditional microbiology assays. Further, we provide a comparative analysis of previous research on various established organ-disease models. Lastly, we provide insight on future techniques that may more accurately test new formulations to meet the growing demand of antibiotic resistant bacterial infections.
Collapse
|
47
|
Ke S, Liu Q, Deng M, Zhang X, Yao Y, Shan M, Yang X, Sui G. Cytotoxicity analysis of indoor air pollution from biomass combustion in human keratinocytes on a multilayered dynamic cell culture platform. CHEMOSPHERE 2018; 208:1008-1017. [PMID: 30068025 DOI: 10.1016/j.chemosphere.2018.06.058] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 06/07/2018] [Indexed: 06/08/2023]
Abstract
Skin tissue is the first barrier against ambient harmful matter and has direct contact with indoor air pollutants. Nevertheless, a comprehensive understanding of cytotoxicity of indoor air pollution on skin cells is insufficiently clear. Herein, for the first time a multilayered dynamic cell culture platform was established to study the cytotoxicity of indoor air pollutant from biomass combustion in human skin keratinocytes. The platform consisted of seven repetitive polydimethylsiloxane modules carrying six pieces of polycarbonate membrane between them as substrate for cell growth to realize the simultaneous dynamic culture of 12 layers of keratinocytes. After exposure to biomass combustion soluble constituents (BCSCs), cell viability under microfluidic platform conditions declined more significantly, and apoptosis rates increased more obviously compared with well plate conditions. Transmission electron microscope showed that keratinocyte microstructures displayed obvious signs of cellular damage. Our study confirmed that the nuclear factor of kappa B (NF-κB) signaling pathway was activated, which significantly increased the Bax/Bcl-2 ratio and tumor necrosis factor-alpha and interleukin 6 expression, indicating that NF-κB signaling pathway was the major factor in BCSCs-induced cytotoxicity. These findings offer an insight into the mechanism of BCSCs-induced cytotoxicity in keratinocytes and provide a theoretical basis for future studies on skin cells.
Collapse
Affiliation(s)
- Shaorui Ke
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, PR China
| | - Qi Liu
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, PR China
| | - Mengsi Deng
- Department of Building Science, Tsinghua University, Beijing 100084, PR China
| | - Xinlian Zhang
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, PR China
| | - Yuhan Yao
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, PR China
| | - Ming Shan
- Department of Building Science, Tsinghua University, Beijing 100084, PR China
| | - Xudong Yang
- Department of Building Science, Tsinghua University, Beijing 100084, PR China.
| | - Guodong Sui
- Shanghai Key Laboratory of Atmospheric Particle Pollution Prevention (LAP3), Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
48
|
Novak C, Horst E, Mehta G. Review: Mechanotransduction in ovarian cancer: Shearing into the unknown. APL Bioeng 2018; 2:031701. [PMID: 31069311 PMCID: PMC6481715 DOI: 10.1063/1.5024386] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 05/21/2018] [Indexed: 12/21/2022] Open
Abstract
Ovarian cancer remains a deadly diagnosis with an 85% recurrence rate and a 5-year survival rate of only 46%. The poor outlook of this disease has improved little over the past 50 years owing to the lack of early detection, chemoresistance and the complex tumor microenvironment. Within the peritoneal cavity, the presence of ascites stimulates ovarian tumors with shear stresses. The stiff environment found within the tumor extracellular matrix and the peritoneal membrane are also implicated in the metastatic potential and epithelial to mesenchymal transition (EMT) of ovarian cancer. Though these mechanical cues remain highly relevant to the understanding and treatment of ovarian cancers, our current knowledge of their biological processes and their clinical relevance is deeply lacking. Seminal studies on ovarian cancer mechanotransduction have demonstrated close ties between mechanotransduction and ovarian cancer chemoresistance, EMT, enhanced cancer stem cell populations, and metastasis. This review summarizes our current understanding of ovarian cancer mechanotransduction and the gaps in knowledge that exist. Future investigations on ovarian cancer mechanotransduction will greatly improve clinical outcomes via systematic studies that determine shear stress magnitude and its influence on ovarian cancer progression, metastasis, and treatment.
Collapse
Affiliation(s)
- Caymen Novak
- Department of Biomedical Engineering, University of
Michigan, Ann Arbor, Michigan 48109-2800,
USA
| | | | - Geeta Mehta
- Author to whom correspondence should be addressed:
| |
Collapse
|
49
|
Buesch S, Schroeder J, Bunger M, D'Souza T, Stosik M. A Novel In Vitro Liver Cell Culture Flow System Allowing Long-Term Metabolism and Hepatotoxicity Studies. ACTA ACUST UNITED AC 2018. [DOI: 10.1089/aivt.2018.0009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
50
|
Ma LD, Wang YT, Wang JR, Wu JL, Meng XS, Hu P, Mu X, Liang QL, Luo GA. Design and fabrication of a liver-on-a-chip platform for convenient, highly efficient, and safe in situ perfusion culture of 3D hepatic spheroids. LAB ON A CHIP 2018; 18:2547-2562. [PMID: 30019731 DOI: 10.1039/c8lc00333e] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Spheroid-based three-dimensional (3D) liver culture models, offering a desirable biomimetic microenvironment, are useful for recapitulating liver functions in vitro. However, a user-friendly, robust and specially optimized method has not been well developed for a convenient, highly efficient, and safe in situ perfusion culture of spheroid-based 3D liver models. Here, we have developed a biomimetic and reversibly assembled liver-on-a-chip (3D-LOC) platform and presented a proof of concept for long-term perfusion culture of 3D human HepG2/C3A spheroids for building a 3D liver spheroid model. On the basis of a fast and reversible seal of concave microwell-based PDMS-membrane-PDMS sandwich multilayer chips, it enables a high-throughput and parallel perfusion culture of 1080 cell spheroids in a high mass transfer and low fluid shear stress biomimetic microenvironment as well as allowing the convenient collection and analysis of the cell spheroids. In terms of reducing spheroid loss and maintaining cell morphology and viability in long-term perfusion culture, the cell spheroids in the 3D-LOC were more safe and efficient. Notably, the polarisation, liver-specific functions, and metabolic activity of the cell spheroids in 3D-LOC were also remarkably improved and exhibited better long-term maintenance over conventional perfusion methods. Additionally, a robust micromilling method that incorporates secondary PDMS coating techniques (SPCs) for fabricating V-shaped concave microwells was also developed. The V-shaped concave microwell arrays exhibited a higher distribution density and aperture ratio, making it easy to form large-scale and uniform-sized cell spheroids with minimum cell loss. In summary, the proposed 3D-LOC could provide a convenient and robust solution for the long-term safe perfusion culture of hepatic spheroids and be beneficial for a variety of potential applications including development of bio-artificial livers, disease modeling, and drug toxicity screening.
Collapse
Affiliation(s)
- Li-Dong Ma
- State Key Laboratory of Quality Research in Chinese Medicine, Macau Institute for Applied Research in Medicine and Health, Macau University of Science and Technology, Macau, China.
| | | | | | | | | | | | | | | | | |
Collapse
|