1
|
Abstract
A hydrogel is a solid form of polymer network absorbed in a substantial amount of aqueous solution. In electrophoresis, hydrogels play versatile roles including as support media, sieving matrixes, affinity scaffolds, and compositions of molecularly imprinting polymers. Recently, the study of hydrogels has been advancing with unprecedented speed, and the application of hydrogels in separation science has brought new opportunities and possible breakthroughs. A good understanding about the roles and effects of the material is essential for hydrogel applications. This review summarizes the hydrogels that has been described in various modes of electrophoretic separations, including isoelectric focusing gel electrophoresis (IEFGE), isotachophoresis (ITP), gel electrophoresis and affinity gel electrophoresis (AGE). As microchip electrophoresis (ME) is one of the future trends in electrophoresis, thought provoking studies related to hydrogels in ME are also introduced. Novel hydrogels and methods that improve separation performance, facilitate the experimental operation process, allow for rapid analysis, and promote the integration to microfluidic devices are highlighted.
Collapse
Affiliation(s)
- Chenchen Liu
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University
| | - Takuya Kubo
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University
| | - Koji Otsuka
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University
| |
Collapse
|
2
|
Bouvarel T, Delaunay N, Pichon V. Molecularly imprinted polymers in miniaturized extraction and separation devices. J Sep Sci 2021; 44:1727-1751. [DOI: 10.1002/jssc.202001223] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 01/18/2021] [Accepted: 01/20/2021] [Indexed: 12/20/2022]
Affiliation(s)
- Thomas Bouvarel
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Nathalie Delaunay
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Valérie Pichon
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
- Sorbonne Université Paris 75005 France
| |
Collapse
|
3
|
Combining capillary electromigration with molecular imprinting techniques towards an optimal separation and determination. Talanta 2021; 221:121546. [DOI: 10.1016/j.talanta.2020.121546] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/19/2020] [Accepted: 08/20/2020] [Indexed: 01/24/2023]
|
4
|
Moreno-González D, Jáč P, Riasová P, Nováková L. In-line molecularly imprinted polymer solid phase extraction-capillary electrophoresis coupled with tandem mass spectrometry for the determination of patulin in apple-based food. Food Chem 2020; 334:127607. [PMID: 32711279 DOI: 10.1016/j.foodchem.2020.127607] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 05/13/2020] [Accepted: 07/16/2020] [Indexed: 01/29/2023]
Abstract
We present a simple and sensitive method for the determination of patulin at µg·kg-1 level in apple-based products. Our method relies on the application of an in-line molecularly imprinted polymer solid-phase extraction microcartridge in capillary electrophoresis coupled with mass spectrometry. Capillary zone electrophoresis method has been developed and parameters affecting the in-line process have been carefully optimized. Validation parameters were assessed for patulin, giving LOQ of 1 µg·kg-1 and linearity range 1-100 µg·kg-1 with R2 ≥ 0.997. The LOQ was below the maximum content of patulin requested by the European Union in this type of products. The precision of the peak area and the migration time were less than 14.9 and 1.6%, respectively. Patulin has been analyzed in the presence of 5-hydroxymethylfurfural, which is the main interference in this kind of matrix. The method was applied to assay patulin content in various apple-based products.
Collapse
Affiliation(s)
- David Moreno-González
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
| | - Pavel Jáč
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| | - Petra Riasová
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
| |
Collapse
|
5
|
Wang S, Xie T, Dong X, Hu J, Men L, Cao J. Determination of Iodine Species in Seafood by Ionic Liquid–Based In-line Solid-Phase Extraction-Capillary Electrophoresis. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01553-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
6
|
A critical retrospective and prospective review of designs and materials in in-line solid-phase extraction capillary electrophoresis. Anal Chim Acta 2019; 1079:1-19. [PMID: 31387699 DOI: 10.1016/j.aca.2019.05.022] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 05/08/2019] [Accepted: 05/10/2019] [Indexed: 11/20/2022]
Abstract
Several strategies have been developed to decrease the concentration limits of detection (LODs) in capillary electrophoresis (CE). Nowadays, chromatographic-based preconcentration using a microcartridge integrated in the separation capillary for in-line solid-phase extraction capillary electrophoresis (SPE-CE) is one of the best alternatives for high throughput and reproducible sample clean-up and analyte preconcentration. This review covers different designs (geometrical configurations, with frits or fritless, capillary types, compatibility with commercial instrumentation, etc.) and materials (sorbents, supports, affinity ligands, etc.) applied for almost 30 years to prepare in-line SPE-CE microcartridges (i.e. analyte concentrators), with emphasis on the conventional unidirectional configuration in capillary format. Advantages, disadvantages and future perspectives are analyzed in detail to provide the reader a wide overview about the great potential of this technique to enhance sensitivity and address trace analysis.
Collapse
|
7
|
An JY, Azizov S, Kumar AP, Lee YI. Quantitative Analysis of Artificial Sweeteners by Capillary Electrophoresis with a Dual-Capillary Design of Molecularly Imprinted Solid-Phase Extractor. B KOREAN CHEM SOC 2018. [DOI: 10.1002/bkcs.11599] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Ji-Yong An
- Department of Chemistry; Changwon National University; Changwon 641-773 Republic of Korea
| | - Shavkatjon Azizov
- Department of Chemistry; Changwon National University; Changwon 641-773 Republic of Korea
| | - Avvaru Praveen Kumar
- Department of Chemistry; Changwon National University; Changwon 641-773 Republic of Korea
| | - Yong-Ill Lee
- Department of Chemistry; Changwon National University; Changwon 641-773 Republic of Korea
| |
Collapse
|
8
|
Hernández-Mesa M, Airado-Rodríguez D, García-Campaña AM, Cruces-Blanco C. Development of an ultrasensitive stacking technique for 5-nitroimidazole determination in untreated biological fluids by micellar electrokinetic chromatography. Electrophoresis 2015; 36:2538-41. [DOI: 10.1002/elps.201500193] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 06/25/2015] [Accepted: 07/06/2015] [Indexed: 11/11/2022]
Affiliation(s)
- Maykel Hernández-Mesa
- Department of Analytical Chemistry; Faculty of Sciences, University of Granada; Granada Spain
| | - Diego Airado-Rodríguez
- Department of Analytical Chemistry; Faculty of Sciences, University of Granada; Granada Spain
| | - Ana M. García-Campaña
- Department of Analytical Chemistry; Faculty of Sciences, University of Granada; Granada Spain
| | - Carmen Cruces-Blanco
- Department of Analytical Chemistry; Faculty of Sciences, University of Granada; Granada Spain
| |
Collapse
|
9
|
Medina-Casanellas S, Tak YH, Benavente F, Sanz-Nebot V, Sastre Toraño J, Somsen GW, de Jong GJ. Evaluation of fritless solid-phase extraction coupled on-line with capillary electrophoresis-mass spectrometry for the analysis of opioid peptides in cerebrospinal fluid. Electrophoresis 2015; 35:2996-3002. [PMID: 25074562 DOI: 10.1002/elps.201400293] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Revised: 07/18/2014] [Accepted: 07/19/2014] [Indexed: 11/07/2022]
Abstract
Fritless SPE on-line coupled to CE with UV and MS detection (SPE-CE-UV and SPE-CE-MS) was evaluated for the analysis of opioid peptides. A microcartridge of 150 μm id was packed with a C18 sorbent (particle size > 50 μm), which was retained between a short inlet capillary and a separation capillary (50 μm id). Several experimental parameters were optimized by SPE-CE-UV using solutions of dynorphin A (DynA), endomorphin 1 (End1), and methionine-enkephaline (Met). A microcartridge length of 4 mm was selected, sample was loaded for 10 min at 930 mbar and the retained peptides were eluted with 67 nL of an acidic hydro-organic solution. Using SPE-CE-MS, peak area and migration time repeatabilities for the three opioid peptides were 12-27% and 4-5%, respectively. SPE recovery was lower for the less hydrophobic DynA (22%) than for End1 (66%) and Met (78%) and linearity was satisfactory in all cases between 5 and 60 ng/mL. The LODs varied between 0.5 and 1.0 ng/mL which represent an enhancement of two orders of magnitude when compared with CE-MS. Cerebrospinal fluid (CSF) samples spiked with the opioid peptides were analyzed to demonstrate the applicability to biological samples. Peak area and migration time repeatabilities were similar to the standard solutions and the opioid peptides could be detected down to 1.0 ng/mL.
Collapse
|
10
|
Elbashir AA, Aboul-Enein HY. Separation and analysis of triazine herbcide residues by capillary electrophoresis. Biomed Chromatogr 2014; 29:835-42. [DOI: 10.1002/bmc.3381] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2014] [Revised: 09/30/2014] [Accepted: 10/07/2014] [Indexed: 01/16/2023]
Affiliation(s)
- Abdalla A. Elbashir
- Chemistry Department, Faculty of Science; University of Khartoum; Khartoum 11115 Sudan
| | - Hassan Y. Aboul-Enein
- Pharmaceutical and Medicinal Chemistry Department, Pharmaceutical and Drug Industries Research Division; National Research Centre; Dokki Cairo 12311 Egypt
| |
Collapse
|
11
|
Whitcombe MJ, Kirsch N, Nicholls IA. Molecular imprinting science and technology: a survey of the literature for the years 2004-2011. J Mol Recognit 2014; 27:297-401. [PMID: 24700625 DOI: 10.1002/jmr.2347] [Citation(s) in RCA: 275] [Impact Index Per Article: 27.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 10/28/2013] [Accepted: 12/01/2013] [Indexed: 12/11/2022]
Abstract
Herein, we present a survey of the literature covering the development of molecular imprinting science and technology over the years 2004-2011. In total, 3779 references to the original papers, reviews, edited volumes and monographs from this period are included, along with recently identified uncited materials from prior to 2004, which were omitted in the first instalment of this series covering the years 1930-2003. In the presentation of the assembled references, a section presenting reviews and monographs covering the area is followed by sections describing fundamental aspects of molecular imprinting including the development of novel polymer formats. Thereafter, literature describing efforts to apply these polymeric materials to a range of application areas is presented. Current trends and areas of rapid development are discussed.
Collapse
|
12
|
Moreno-González D, Lara FJ, Gámiz-Gracia L, García-Campaña AM. Molecularly imprinted polymer as in-line concentrator in capillary electrophoresis coupled with mass spectrometry for the determination of quinolones in bovine milk samples. J Chromatogr A 2014; 1360:1-8. [DOI: 10.1016/j.chroma.2014.07.049] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2014] [Revised: 07/15/2014] [Accepted: 07/17/2014] [Indexed: 12/31/2022]
|
13
|
Rojano-Delgado AM, Luque de Castro MD. Capillary electrophoresis and herbicide analysis: Present and future perspectives. Electrophoresis 2014; 35:2509-19. [DOI: 10.1002/elps.201300556] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 04/16/2014] [Accepted: 04/23/2014] [Indexed: 11/09/2022]
Affiliation(s)
- Antonia María Rojano-Delgado
- Department of Agricultural Chemistry and Soil Science; Córdoba Spain
- Campus of Rabanales, and Agroalimentary Excellence Campus; ceiA3, University of Córdoba; Córdoba Spain
| | - María D. Luque de Castro
- Department of Analytical Chemistry; Córdoba Spain
- Campus of Rabanales, and Agroalimentary Excellence Campus; ceiA3, University of Córdoba; Córdoba Spain
| |
Collapse
|
14
|
Recent advances in solid-phase sorbents for sample preparation prior to chromatographic analysis. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.03.011] [Citation(s) in RCA: 280] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
15
|
Fang R, Yi LX, Shao YX, Zhang L, Chen GH. ON-LINE PRECONCENTRATION IN CAPILLARY ELECTROPHORESIS FOR ANALYSIS OF AGROCHEMICAL RESIDUES. J LIQ CHROMATOGR R T 2014. [DOI: 10.1080/10826076.2013.794740] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Rou Fang
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Ling-Xiao Yi
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Yu-Xiu Shao
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Li Zhang
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| | - Guan-Hua Chen
- a College of Food and Bioengineering , Jiangsu University , Zhenjiang , China
| |
Collapse
|
16
|
Maijó I, Borrull F, Aguilar C, Calull M. Different strategies for the preconcentration and separation of parabens by capillary electrophoresis. Electrophoresis 2013; 34:363-73. [DOI: 10.1002/elps.201200147] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2012] [Revised: 09/14/2012] [Accepted: 09/15/2012] [Indexed: 11/11/2022]
Affiliation(s)
- Irene Maijó
- Department of Analytical Chemistry and Organic Chemistry; Faculty of Chemistry; Rovira i Virgili University; Tarragona; Spain
| | - Francesc Borrull
- Department of Analytical Chemistry and Organic Chemistry; Faculty of Chemistry; Rovira i Virgili University; Tarragona; Spain
| | - Carme Aguilar
- Department of Analytical Chemistry and Organic Chemistry; Faculty of Chemistry; Rovira i Virgili University; Tarragona; Spain
| | - Marta Calull
- Department of Analytical Chemistry and Organic Chemistry; Faculty of Chemistry; Rovira i Virgili University; Tarragona; Spain
| |
Collapse
|
17
|
Zhang X, Xu S, Lee YI, Soper SA. LED-induced in-column molecular imprinting for solid phase extraction/capillary electrophoresis. Analyst 2013; 138:2821-4. [DOI: 10.1039/c3an00257h] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
18
|
Wen Y, Li J, Ma J, Chen L. Recent advances in enrichment techniques for trace analysis in capillary electrophoresis. Electrophoresis 2012; 33:2933-52. [PMID: 23019127 DOI: 10.1002/elps.201200240] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Revised: 06/06/2012] [Accepted: 06/28/2012] [Indexed: 01/25/2023]
Abstract
CE is gaining great popularity as a well-established separation technique for many fields such as pharmaceutical research, clinical application, environmental monitoring, and food analysis, owing to its high resolving power, rapidity, and small amount of samples and reagents required. However, the sensitivity in CE analysis is still considered as being inferior to that in HPLC analysis. Diverse enrichment methods and techniques have been increasingly developed for overcoming this issue. In this review, we summarize the recent advances in enrichment techniques containing off-line preconcentration (sample preparation) and on-line concentration (sample stacking) to enhancing sensitivity in CE for trace analysis over the last 5 years. Some relatively new cleanup and preconcentration methods involving the use of dispersive liquid-liquid microextraction, supercritical fluid extraction, matrix solid-phase dispersion, etc., and the continued use and improvement of conventional SPE, have been comprehensively reviewed and proved effective preconcentration alternatives for liquid, semisolid, and solid samples. As for CE on-line stacking, we give an overview of field amplication, sweeping, pH regulation, and transient isotachophoresis, and the coupling of multiple modes. Moreover, some limitations and comparisons related to such methods/techniques are also discussed. Finally, the combined use of various enrichment techniques and some significant attempts are proposed to further promote analytical merits in CE.
Collapse
Affiliation(s)
- Yingying Wen
- Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research-YIC, Chinese Academy of Sciences-CAS, Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, P. R. China
| | | | | | | |
Collapse
|
19
|
Kohler I, Schappler J, Rudaz S. Microextraction techniques combined with capillary electrophoresis in bioanalysis. Anal Bioanal Chem 2012; 405:125-41. [PMID: 22965532 DOI: 10.1007/s00216-012-6367-y] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2012] [Revised: 08/14/2012] [Accepted: 08/19/2012] [Indexed: 11/28/2022]
Abstract
Over the past two decades, many environmentally sustainable sample-preparation techniques have been proposed, with the objective of reducing the use of toxic organic solvents or substituting these with environmentally friendly alternatives. Microextraction techniques (MEs), in which only a small amount of organic solvent is used, have several advantages, including reduced sample volume, analysis time, and operating costs. Thus, MEs are well adapted in bioanalysis, in which sample preparation is mandatory because of the complexity of a sample that is available in small quantities (mL or even μL only). Capillary electrophoresis (CE) is a powerful and efficient separation technique in which no organic solvents are required for analysis. Combination of CE with MEs is regarded as a very attractive environmentally sustainable analytical tool, and numerous applications have been reported over the last few decades for bioanalysis of low-molecular-weight compounds or for peptide analysis. In this paper we review the use of MEs combined with CE in bioanalysis. The review is divided into two sections: liquid and solid-based MEs. A brief practical and theoretical description of each ME is given, and the techniques are illustrated by relevant applications.
Collapse
Affiliation(s)
- Isabelle Kohler
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Bd d'Yvoy 20, 1211 Geneva 4, Switzerland
| | | | | |
Collapse
|
20
|
Wen Y, Chen L, Li J, Ma Y, Xu S, Zhang Z, Niu Z, Choo J. Molecularly imprinted matrix solid-phase dispersion coupled to micellar electrokinetic chromatography for simultaneous determination of triazines in soil, fruit, and vegetable samples. Electrophoresis 2012; 33:2454-63. [DOI: 10.1002/elps.201100612] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
| | - Lingxin Chen
- Key Laboratory of Coastal Zone Environmental Processes; Yantai Institute of Coastal Zone Research (YIC); Chinese Academy of Sciences (CAS); Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes; YICCAS; Yantai; China
| | - Jinhua Li
- Key Laboratory of Coastal Zone Environmental Processes; Yantai Institute of Coastal Zone Research (YIC); Chinese Academy of Sciences (CAS); Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes; YICCAS; Yantai; China
| | | | | | - Zhong Zhang
- Key Laboratory of Coastal Zone Environmental Processes; Yantai Institute of Coastal Zone Research (YIC); Chinese Academy of Sciences (CAS); Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes; YICCAS; Yantai; China
| | - Zongliang Niu
- Key Laboratory of Coastal Zone Environmental Processes; Yantai Institute of Coastal Zone Research (YIC); Chinese Academy of Sciences (CAS); Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes; YICCAS; Yantai; China
| | - Jaebum Choo
- Department of Bionano Engineering, Hanyang University; Ansan; South Korea
| |
Collapse
|
21
|
Guijarro-Díez M, Paniagua G, Fernández P, Crego AL, Marina ML. Molecularly imprinted SPE and MEKC with in-capillary sample preconcentration for the determination of digoxin in human urine. Electrophoresis 2012; 33:1582-8. [DOI: 10.1002/elps.201100588] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Miguel Guijarro-Díez
- Departamento de Química Analítica; Facultad de Química; Universidad de Alcalá; Madrid; Spain
| | - Gema Paniagua
- Departamento de Ciencias Analíticas; Facultad de Ciencias; Universidad Nacional de Educación a Distancia (UNED); Madrid; Spain
| | - Pilar Fernández
- Departamento de Ciencias Analíticas; Facultad de Ciencias; Universidad Nacional de Educación a Distancia (UNED); Madrid; Spain
| | - Antonio Luis Crego
- Departamento de Química Analítica; Facultad de Química; Universidad de Alcalá; Madrid; Spain
| | - María Luisa Marina
- Departamento de Química Analítica; Facultad de Química; Universidad de Alcalá; Madrid; Spain
| |
Collapse
|
22
|
Chen C, Zhang X, Long Z, Zhang J, Zheng C. Molecularly imprinted dispersive solid-phase microextraction for determination of sulfamethazine by capillary electrophoresis. Mikrochim Acta 2012. [DOI: 10.1007/s00604-012-0833-2] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
23
|
Bubble cell for magnetic bead trapping in capillary electrophoresis. Anal Bioanal Chem 2011; 401:3239-48. [DOI: 10.1007/s00216-011-5417-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2011] [Revised: 09/02/2011] [Accepted: 09/05/2011] [Indexed: 11/25/2022]
|
24
|
Maijó I, Borrull F, Calull M, Aguilar C. An in-line SPE strategy to enhance sensitivity in CE for the determination of pharmaceutical compounds in river water samples. Electrophoresis 2011; 32:2114-22. [DOI: 10.1002/elps.201100054] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Revised: 04/29/2011] [Accepted: 05/03/2011] [Indexed: 11/05/2022]
|
25
|
Determination of trace bisphenol A in complex samples using selective molecularly imprinted solid-phase extraction coupled with capillary electrophoresis. Microchem J 2011. [DOI: 10.1016/j.microc.2011.01.003] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
26
|
Beltran A, Borrull F, Marcé R, Cormack P. Molecularly-imprinted polymers: useful sorbents for selective extractions. Trends Analyt Chem 2010. [DOI: 10.1016/j.trac.2010.07.020] [Citation(s) in RCA: 181] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
27
|
Breadmore MC, Dawod M, Quirino JP. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2008-2010). Electrophoresis 2010; 32:127-48. [PMID: 21171119 DOI: 10.1002/elps.201000412] [Citation(s) in RCA: 129] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2010] [Revised: 09/15/2010] [Accepted: 09/16/2010] [Indexed: 01/22/2023]
Abstract
Capillary electrophoresis has been alive for over two decades now; yet, its sensitivity is still regarded as being inferior to that of more traditional methods of separation such as HPLC. As such, it is unsurprising that overcoming this issue still generates much scientific interest. This review continues to update this series of reviews, first published in Electrophoresis in 2007, with an update published in 2009 and covers material published through to June 2010. It includes developments in the fields of stacking, covering all methods from field-amplified sample stacking and large volume sample stacking, through to ITP, dynamic pH junction and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
Collapse
Affiliation(s)
- Michael C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Hobart, TAS, Australia.
| | | | | |
Collapse
|
28
|
Boonjob W, Yu Y, Miró M, Segundo MA, Wang J, Cerdà V. Online hyphenation of multimodal microsolid phase extraction involving renewable molecularly imprinted and reversed-phase sorbents to liquid chromatography for automatic multiresidue assays. Anal Chem 2010; 82:3052-60. [PMID: 20218575 DOI: 10.1021/ac100185s] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Molecular imprinted polymers (MIP) have recently drawn much attention as highly selective solid-phase materials for handling and isolation of organic pollutants in complex matrices. Because of the impaired retention capacity for target species as compared with reversed-phase materials and irreversible sorption of interfering compounds by nonspecific interactions, the implementation of MIP-based solid-phase reactors as permanent components in automatic flow-systems has not received widespread acceptance as of yet. To tackle this limitation, a dynamic microscale solid phase extraction (microSPE) method capitalizing on the principle of programmable flow and bead injection analysis is herein proposed as a front end to liquid chromatography for multiresidue assays. It involves in-line renewable tandem-SPE microcolumns composed of molecularly imprinted polymers and copolymeric N-vinylpyrrolidone/divinylbenzene beads integrated within the flow network for multimodal extraction. Chlorotriazine herbicides (namely, atrazine, simazine, propazine) and principal degradation products thereof (namely, deisopropylatrazine and deethylatrazine) were selected as model analytes. The effect of several parameters, including the dimensions and chemical composition of the sorptive microcolumns, the sample loading flow rate, the type and volume of eluent, the interface with liquid chromatography (LC), and the disposable nature of the column on the analytical performance were investigated in detail. The assembled flow setup features appropriate removal of interfering organic species via solvent switch with toluene, the circumvention of analyte band-broadening in LC by in-line merging of the eluate with a water stream, and the transfer of the overall analyte-containing eluate into the LC. For 10-mL sample percolation, limits of detection (S/N = 3) of 0.02-0.04 ng mL(-1), limits of quantification (S/N = 10) of 0.07-0.12 ng mL(-1), absolute recovery percentages >79%, precision within 1.4-5.5%, and enrichment factors of 46-49 were obtained for the suite of assayed herbicides. The multimodal microSPE method with renewable beads was applied to the multiresidue determination of the target herbicides in crude soil extracts and untreated environmental waters at concentration levels below those endorsed by the current EU Water Framework Directives following appropriate sample preconcentration and/or cleanup.
Collapse
Affiliation(s)
- Warunya Boonjob
- Department of Chemistry, Faculty of Sciences, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma de Mallorca, Illes Balears, Spain
| | | | | | | | | | | |
Collapse
|
29
|
Affiliation(s)
- Nicholas W. Frost
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455
| | - Meng Jing
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455
| | - Michael T. Bowser
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455
| |
Collapse
|
30
|
|
31
|
|
32
|
Rosengren AM, Golker K, Karlsson JG, Nicholls IA. Dielectric constants are not enough: principal component analysis of the influence of solvent properties on molecularly imprinted polymer-ligand rebinding. Biosens Bioelectron 2009; 25:553-7. [PMID: 19646857 DOI: 10.1016/j.bios.2009.06.042] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2009] [Revised: 06/23/2009] [Accepted: 06/24/2009] [Indexed: 11/17/2022]
Abstract
The influence of the physical properties of incubation medium on the rebinding of template to bupivacaine molecularly imprinted and non-imprinted methacrylic acid-ethylene dimethacrylate co-polymers has been studied. Principal component analysis (PCA) was employed to identify the factors with the greatest influence on binding. While the dielectric constant (D) made a significant contribution to describing the observed binding, the influence of polarity as reflected in the Snyder polarity index (SPI) was also demonstrated to make a significant contribution. The use of solvents containing hydroxyl functionality in particular was observed to exert unique effects on recognition. The variation in solvent influence on binding at constant D motivates more complex analyses when studying MIP-ligand recognition.
Collapse
Affiliation(s)
- Annika M Rosengren
- Bioorganic & Biophysical Chemistry Laboratory, School of Pure & Applied Natural Sciences, University of Kalmar, SE-391 82 Kalmar, Sweden.
| | | | | | | |
Collapse
|
33
|
Determination of sulfonamide residues in water samples by in-line solid-phase extraction-capillary electrophoresis. J Chromatogr A 2009; 1216:3372-9. [DOI: 10.1016/j.chroma.2009.01.097] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2008] [Revised: 01/14/2009] [Accepted: 01/29/2009] [Indexed: 11/22/2022]
|