1
|
Ahmad F, Soe S, Albon J, Errington R, Theobald P. Quantifying the microstructural and biomechanical changes in the porcine ventricles during growth and remodelling. Acta Biomater 2023; 171:166-192. [PMID: 37797709 DOI: 10.1016/j.actbio.2023.09.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 09/19/2023] [Accepted: 09/26/2023] [Indexed: 10/07/2023]
Abstract
Cardiac tissue growth and remodelling (G & R) occur in response to the changing physiological demands of the heart after birth. The early shift to pulmonary circulation produces an immediate increase in ventricular workload, causing microstructural and biomechanical changes that serve to maintain overall physiological homoeostasis. Such cardiac G & R continues throughout life. Quantifying the tissue's mechanical and microstructural changes because of G & R is of increasing interest, dovetailing with the emerging fields of personalised and precision solutions. This study aimed to determine equibiaxial, and non-equibiaxial extension, stress-relaxation, and the underlying microstructure of the passive porcine ventricles tissue at four time points spanning from neonatal to adulthood. The three-dimensional microstructure was investigated via two-photon excited fluorescence and second-harmonic generation microscopy on optically cleared tissues, describing the 3D orientation, rotation and dispersion of the cardiomyocytes and collagen fibrils. The results revealed that during biomechanical testing, myocardial ventricular tissue possessed non-linear, anisotropic, and viscoelastic behaviour. An increase in stiffness and viscoelasticity was noted for the left and right ventricular free walls from neonatal to adulthood. Microstructural analyses revealed concomitant increases in cardiomyocyte rotation and dispersion. This study provides baseline data, describing the biomechanical and microstructural changes in the left and right ventricular myocardial tissue during G & R, which should prove valuable to researchers in developing age-specific, constitutive models for more accurate computational simulations. STATEMENT OF SIGNIFICANCE: There is a dearth of experimental data describing the growth and remodelling of left and right ventricular tissue. The published literature is fragmented, with data reported via different experimental techniques using tissues harvested from a variety of animals, with different gender and ages. This prevents developing a continuum of data spanning birth to death, so limiting the potential that can be leveraged to aid computational modelling and simulations. In this study, equibiaxial, non-equibiaxial, and stress-relaxation data are presented, describing directional-dependent material responses. The biomechanical data is consolidated with equivalent microstructural data, an important element for the development of future material models. Combined, these data describe microstructural and biomechanical changes in the ventricles, spanning G &R from neonatal to adulthood.
Collapse
Affiliation(s)
- Faizan Ahmad
- School of Engineering, Cardiff University, UK; School of Health Sciences, Birmingham City University, UK.
| | - Shwe Soe
- FET - Engineering, Design and Mathematics, University of West of England, UK
| | - Julie Albon
- School of Optometry and Vision Sciences, Cardiff University, UK; Viva Scientia Bioimaging Laboratories, Cardiff University, UK
| | | | | |
Collapse
|
2
|
Wu W, Ching S, Sabin P, Laurence DW, Maas SA, Lasso A, Weiss JA, Jolley MA. The effects of leaflet material properties on the simulated function of regurgitant mitral valves. J Mech Behav Biomed Mater 2023; 142:105858. [PMID: 37099920 PMCID: PMC10199327 DOI: 10.1016/j.jmbbm.2023.105858] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/30/2023] [Accepted: 04/12/2023] [Indexed: 04/28/2023]
Abstract
Advances in three-dimensional imaging provide the ability to construct and analyze finite element (FE) models to evaluate the biomechanical behavior and function of atrioventricular valves. However, while obtaining patient-specific valve geometry is now possible, non-invasive measurement of patient-specific leaflet material properties remains nearly impossible. Both valve geometry and tissue properties play a significant role in governing valve dynamics, leading to the central question of whether clinically relevant insights can be attained from FE analysis of atrioventricular valves without precise knowledge of tissue properties. As such we investigated (1) the influence of tissue extensibility and (2) the effects of constitutive model parameters and leaflet thickness on simulated valve function and mechanics. We compared metrics of valve function (e.g., leaflet coaptation and regurgitant orifice area) and mechanics (e.g., stress and strain) across one normal and three regurgitant mitral valve (MV) models with common mechanisms of regurgitation (annular dilation, leaflet prolapse, leaflet tethering) of both moderate and severe degree. We developed a novel fully-automated approach to accurately quantify regurgitant orifice areas of complex valve geometries. We found that the relative ordering of the mechanical and functional metrics was maintained across a group of valves using material properties up to 15% softer than the representative adult mitral constitutive model. Our findings suggest that FE simulations can be used to qualitatively compare how differences and alterations in valve structure affect relative atrioventricular valve function even in populations where material properties are not precisely known.
Collapse
Affiliation(s)
- Wensi Wu
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA; Division of Pediatric Cardiology, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA
| | - Stephen Ching
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA
| | - Patricia Sabin
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA
| | - Devin W Laurence
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA; Division of Pediatric Cardiology, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA
| | - Steve A Maas
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, UT, USA; Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, UT, USA
| | - Andras Lasso
- Laboratory for Percutaneous Surgery, Queen's University, Kingston, ON, Canada
| | - Jeffrey A Weiss
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, UT, USA; Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, UT 84112, UT, USA
| | - Matthew A Jolley
- Department of Anesthesiology and Critical Care Medicine, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA; Division of Pediatric Cardiology, Children's Hospital of Philadelphia, Philadelphia, 19104, PA, USA.
| |
Collapse
|
3
|
Wang B, Sierad LN, Mercuri JJ, Simionescu A, Simionescu DT, Williams LN, Vela R, Bajona P, Peltz M, Ramaswamy S, Hong Y, Liao J. Structural and biomechanical characterizations of acellular porcine mitral valve scaffolds: anterior leaflets, posterior leaflets, and chordae tendineae. ENGINEERED REGENERATION 2022; 3:374-386. [PMID: 38362305 PMCID: PMC10869114 DOI: 10.1016/j.engreg.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Mitral valve (MV) tissue engineering is still in its early stage, and one major challenge in MV tissue engineering is to identify appropriate scaffold materials. With the potential of acellular MV scaffolds being demonstrated recently, it is important to have a full understanding of the biomechanics of the native MV components and their acellular scaffolds. In this study, we have successfully characterized the structural and mechanical properties of porcine MV components, including anterior leaflet (AL), posterior leaflet (PL), strut chordae, and basal chordae, before and after decellularization. Quantitative DNA assay showed more than 90% reduction in DNA content, and Griffonia simplicifolia (GS) lectin immunohistochemistry confirmed the complete lack of porcine α-Gal antigen in the acellular MV components. In the acellular AL and PL, the atrialis, spongiosa, and fibrosa trilayered structure, along with its ECM constitutes, i.e., collagen fibers, elastin fibers, and portion of GAGs, were preserved. Nevertheless, the ECM of both AL and PL experienced a certain degree of disruption, exhibiting a less dense, porous ECM morphology. The overall anatomical morphology of the strut and basal chordae were also maintained after decellularization, with longitudinal morphology experiencing minimum disruption, but the cross-sectional morphology exhibiting evenly-distributed porous structure. In the acellular AL and PL, the nonlinear anisotropic biaxial mechanical behavior was overall preserved; however, uniaxial tensile tests showed that the removal of cellular content and the disruption of structural ECM did result in small decreases in maximum tensile modulus, tissue extensibility, failure stress, and failure strain for both MV leaflets and chordae.
Collapse
Affiliation(s)
- Bo Wang
- Joint Department of Biomedical Engineering, Medical College of Wisconsin and Marquette University, Milwaukee, WI 53226, United States
| | - Leslie N. Sierad
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Jeremy J. Mercuri
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Agneta Simionescu
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Dan T. Simionescu
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Lakiesha N. Williams
- Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, United States
| | - Ryan Vela
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
| | - Pietro Bajona
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
- Allegheny Health Network-Drexel University College of Medicine, Pittsburgh, PA 15212, United States
| | - Matthias Peltz
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
| | - Sharan Ramaswamy
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, United States
| | - Yi Hong
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76010, United States
| | - Jun Liao
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76010, United States
| |
Collapse
|
4
|
Pandya PK, Wilkerson RJ, Imbrie-Moore AM, Zhu Y, Marin-Cuartas M, Park MH, Woo YJ. Quantitative biomechanical optimization of neochordal implantation location on mitral leaflets during valve repair. JTCVS Tech 2022; 14:89-93. [PMID: 35967240 PMCID: PMC9366621 DOI: 10.1016/j.xjtc.2022.05.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 04/01/2022] [Accepted: 05/10/2022] [Indexed: 11/01/2022] Open
Abstract
Objective Suture pull-out remains a significant mechanism of long-term neochordal repair failure, as demonstrated by clinical reports on recurrent mitral valve regurgitation and need for reoperation. The objective of this study was to provide a quantitative comparison of suture pull-out forces for various neochordal implantation locations. Methods Posterior leaflets were excised from fresh porcine mitral valves (n = 54) and fixed between two 3-dimensional-printed plates. Gore-Tex CV-5 sutures (WL Gore & Associates Inc) were placed with distances from the leading edge and widths between anchoring sutures with values of 2 mm, 6 mm, and 10 mm for a total of 9 groups (n = 6 per group). Mechanical testing was performed using a tensile testing machine to evaluate pull-out force of the suture through the mitral valve leaflet. Results Increasing the suture anchoring width improved failure strength significantly across all leading-edge distances (P < .001). Additionally, increasing the leading-edge distance from 2 mm to 6 mm increased suture pull-out forces significantly across all suture widths (P < .001). For 6-mm and 10-mm widths, increasing the leading-edge distance from 6 mm to 10 mm increased suture pull-out forces by an average of 3.58 ± 0.15 N; in comparison, for leading-edge distances of 6 mm and 10 mm, increasing the suture anchoring width from 6 mm to 10 mm improves the force by an average of 7.09 ± 0.44 N. Conclusions Increasing suture anchoring width and leading-edge distance improves the suture pull-out force through the mitral leaflet, which may optimize postrepair durability. The results suggest a comparative advantage to increasing suture anchoring width compared with leading-edge distance.
Collapse
Affiliation(s)
- Pearly K. Pandya
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- Department of Mechanical Engineering, Stanford University, Stanford, Calif
| | | | - Annabel M. Imbrie-Moore
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- Department of Mechanical Engineering, Stanford University, Stanford, Calif
| | - Yuanjia Zhu
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- Department of Bioengineering, Stanford University, Stanford, Calif
| | - Mateo Marin-Cuartas
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- University Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | - Matthew H. Park
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- Department of Mechanical Engineering, Stanford University, Stanford, Calif
| | - Y. Joseph Woo
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
- Department of Bioengineering, Stanford University, Stanford, Calif
| |
Collapse
|
5
|
Vandemaele P, Vander Linden K, Deferm S, Jashari R, Rega F, Bertrand P, Vandervoort P, Vander Sloten J, Famaey N, Fehervary H. Alterations in Human Mitral Valve Mechanical Properties Secondary to Left Ventricular Remodeling: A Biaxial Mechanical Study. Front Cardiovasc Med 2022; 9:876006. [PMID: 35811738 PMCID: PMC9258718 DOI: 10.3389/fcvm.2022.876006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 04/11/2022] [Indexed: 11/18/2022] Open
Abstract
Secondary mitral regurgitation occurs when a left ventricular problem causes leaking of the mitral valve. The altered left ventricular geometry changes the orientation of the subvalvular apparatus, thereby affecting the mechanical stress on the mitral valve. This in turn leads to active remodeling of the mitral valve, in order to compensate for the ventricular remodeling. In this study, a biomechanical analysis was performed on eight human mitral valves with secondary mitral regurgitation and ten healthy human mitral valves to better understand this pathophysiology and its effect on the mechanical properties of these tissues. Samples were obtained from the anterior and posterior leaflet and used for planar biaxial mechanical experiments. Uniaxial experiments were performed on four groups of mitral valve chords: anterior basal, anterior marginal, posterior basal and posterior marginal chords. The mechanical response of the mitral valve leaflets was fitted to the May-Newman and Yin constitutive model, whereas the material parameters of the third order Ogden model were determined for the chord samples. Next, stiffnesses calculated at low and high stress levels were statistically analyzed. Leaflet samples with secondary mitral regurgitation showed a small thickness increase and a change in anisotropy index compared to healthy control valves. Diseased leaflets were more compliant circumferentially and stiffer radially, resulting in anisotropic samples with the radial direction being stiffest. In addition, chord samples were slightly thicker and less stiff at high stress in secondary mitral regurgitation, when grouped per leaflet type and insertion region. These results confirm mechanical alterations due to the pathophysiological valvular changes caused by left ventricular remodeling. It is important that these changes in mechanical behavior are incorporated into computational models of the mitral valve.
Collapse
Affiliation(s)
- Paulien Vandemaele
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Klaas Vander Linden
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Sébastien Deferm
- Cardiology, Hospital Oost-Limburg, Genk, Belgium
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Ramadan Jashari
- European Homograft Bank, Clinic Saint-Jean, Brussels, Belgium
| | - Filip Rega
- Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | | | - Pieter Vandervoort
- Cardiology, Hospital Oost-Limburg, Genk, Belgium
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Jos Vander Sloten
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Nele Famaey
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
- FIBEr, KU Leuven, Leuven, Belgium
| | - Heleen Fehervary
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
- FIBEr, KU Leuven, Leuven, Belgium
| |
Collapse
|
6
|
Zhao D, Wang H, Deng J, Slavashevich I, Guo X, Mei Y, Sun C. Optical Coherence Elastography of 3D bilayer soft solids using full-field and partial displacement measurements. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
7
|
Rosakis A, Gharib M. The Influence of Valve Leaflet Stiffness Variability on Aortic Wall Shear Stress. Ann Biomed Eng 2022; 50:29-38. [PMID: 34993697 DOI: 10.1007/s10439-021-02899-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 12/01/2021] [Indexed: 11/30/2022]
Abstract
Aortic stenosis is a common cardiac condition that impacts the aorta's hemodynamics downstream of the affected valve. We sought to better understand how non-uniform stiffening of a stenotic aortic valve would affect the wall shear stress (WSS) experienced by the walls of the aorta and the residence time near the valve. Several experimental configurations were created by individually stiffening leaflets of a polymer aortic valve. These configurations were mounted inside an in vitro experimental setup. Digital particle image velocimetry (DPIV) was used to measure velocity profiles inside a model aorta. The DPIV results were used to estimate the WSS and residence time. Our analysis suggests that leaflet asymmetry greatly affects the amount of WSS by vectoring the systolic jet and stiffened leaflets have an increased residence time. This study indicates that valve leaflets with different stiffness conditions can have a more significant impact on wall shear stress than stenosis caused by the uniform increase in all three leaflets (and the subsequent increased systolic velocity) alone. This finding is promising for creating customizable (patient-specific) prosthetic heart valves tailored to individual patients.
Collapse
Affiliation(s)
| | - Morteza Gharib
- Caltech, 1200 E California Blvd, MC 105-50, Pasadena, CA, 91125, USA
| |
Collapse
|
8
|
Kruithof BPT, Paardekooper L, Hiemstra YL, Goumans MJ, Palmen M, Delgado V, Klautz RJM, Ajmone Marsan N. Stress-induced remodelling of the mitral valve: a model for leaflet thickening and superimposed tissue formation in mitral valve disease. Cardiovasc Res 2020; 116:931-943. [PMID: 31497851 DOI: 10.1093/cvr/cvz204] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2019] [Revised: 07/16/2019] [Accepted: 09/02/2019] [Indexed: 11/15/2022] Open
Abstract
AIMS In mitral valve prolapse (MVP), leaflet thickening has recently been suggested to be due, in addition to a myxomatous degeneration, to the presence of a superimposed tissue (SIT), defined as an additional fibrous layer on top of the original leaflet. The mechanisms of SIT formation are currently unknown. We hypothesized that SIT formation would result from excessive leaflet stress and we used a unique ex vivo model to assess the correlation between leaflet remodelling and the type and location of mechanical stress and to elucidate the mechanisms underlying SIT formation. METHODS AND RESULTS Human diseased mitral valves (MVs; n = 21) were histologically analysed for SIT formation and original leaflet thickening. The SIT comprised of various compositions of extracellular matrix and could reach more than 50% of total leaflet thickness. Original leaflet and SIT thickness did not show significant correlation (r = -0.27, P = 0.23), suggesting different regulatory mechanisms. To study the role of the mechanical environment on MV remodelling, mouse MV were cultured in their natural position in the heart and subjected to various haemodynamic conditions representing specific phases of the cardiac cycle and the MVP configuration. SIT formation was induced in the ex vivo model, mostly present on the atrial side, and clearly dependent on the duration, type, and extent of mechanical stress. Specific stainings and lineage tracing experiments showed that SIT comprises of macrophages and myofibroblasts and is associated with the activation of the transforming growth factor-beta and bone morphogenetic protein signalling pathways. Migration of valvular interstitial cells and macrophages through breakages of the endothelial cell lining contributed to SIT formation. CONCLUSIONS Mechanical stresses induce specific cellular and molecular changes in the MV that result in SIT formation. These observations provide the first insights in the mechanism of SIT formation and represent an initial step to identify potential novel and early treatment for MVP.
Collapse
Affiliation(s)
- Boudewijn P T Kruithof
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands.,Department of Cell and Chemical Biology, Leiden University Medical Center, Einthovenweg 20, 2333 ZC Leiden, The Netherlands.,Netherlands Heart Institute, Moreelsepark 1, 3511 EP Utrecht, The Netherlands
| | - Laura Paardekooper
- Department of Cell and Chemical Biology, Leiden University Medical Center, Einthovenweg 20, 2333 ZC Leiden, The Netherlands
| | - Yasmine L Hiemstra
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
| | - Marie-José Goumans
- Department of Cell and Chemical Biology, Leiden University Medical Center, Einthovenweg 20, 2333 ZC Leiden, The Netherlands
| | - Meindert Palmen
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
| | - Victoria Delgado
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
| | - Robert J M Klautz
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
| | - Nina Ajmone Marsan
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2300 RC Leiden, The Netherlands
| |
Collapse
|
9
|
Caballero A, McKay R, Sun W. Computer simulations of transapical mitral valve repair with neochordae implantation: Clinical implications. JTCVS OPEN 2020; 3:27-44. [PMID: 36003874 PMCID: PMC9390497 DOI: 10.1016/j.xjon.2020.05.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 05/21/2020] [Accepted: 05/28/2020] [Indexed: 06/15/2023]
Abstract
OBJECTIVES Transapical beating heart neochordae implantation is an innovative mitral valve repair technique that has demonstrated promising clinical results in patients with primary mitral regurgitation. However, as clinical experience continues to increase, neochordae implantation criteria have not been fully standardized. The aim of this study was to investigate the biomechanical effects of selecting an antero-lateral apical access site compared with a postero-lateral site, and suboptimal neochordae length compared with optimal suture length, on restoring physiologic left heart dynamics. METHODS Transapical neochordae implantation using 3 and 4 sutures was computer simulated under 3 posterior mitral leaflet prolapse conditions: isolated P2, multiscallop P2/P3 and multiscallop P2/P1. Physiologic, pre- and postrepair left heart dynamics were evaluated using a fluid-structure interaction modeling framework. RESULTS Despite the absence of residual mitral regurgitation in all postrepair models with optimal neochordae length, selecting an antero-lateral apical entry site for the treatment of P2/P3 prolapse generated a significant increase (>80%) in neochordae tension and P2 peak stress, with respect to a postero-lateral entry site. During isolated P2 prolapse repair, although neochordae overtension by 5% led to minimal hemodynamic changes in the regurgitant volume compared with using an optimal suture length, a significant increase in systolic and diastolic neochordae tension (>300%) and posterior leaflet average stress (70%-460%) was quantified. On the other hand, neochordae undertension by 5% led to worsening of regurgitation severity. CONCLUSIONS This parametric computer study represents a further step toward an improved understanding of the biomechanical outcomes of transapical neochordae technologies.
Collapse
Key Words
- AL-NC, antero-lateral neochordae
- AML, anterior mitral leaflet
- AV, aortic valve
- FSI, fluid-structure interaction
- LV, left ventricle
- MR, mitral regurgitation
- MV, mitral valve
- NC, neochordae
- PL-NC, postero-lateral neochordae
- PM, papillary muscle
- PML, posterior mitral leaflet
- beating heart mitral valve repair
- ePTFE suture
- ePTFE, expanded polytetrafluoroethylene
- fluid-structure interaction FSI
- primary mitral regurgitation
- transapical neochord
Collapse
Affiliation(s)
- Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Ga
| | - Raymond McKay
- Division of Cardiology, The Hartford Hospital, Hartford, Conn
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Ga
| |
Collapse
|
10
|
Caballero A, Mao W, McKay R, Sun W. Transapical mitral valve repair with neochordae implantation: FSI analysis of neochordae number and complexity of leaflet prolapse. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3297. [PMID: 31833663 DOI: 10.1002/cnm.3297] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 11/05/2019] [Accepted: 12/09/2019] [Indexed: 06/10/2023]
Abstract
Transapical mitral valve repair with neochordae implantation is a relatively new minimally invasive technique to treat primary mitral regurgitation. Quantifying the complex biomechanical interaction and interdependence between the left heart structures and the neochordae during this procedure is technically challenging. The aim of this parametric computational study is to investigate the immediate effects of neochordae number and complexity of leaflet prolapse on restoring physiologic left heart dynamics after optimal transapical neochordae repair procedures. Neochordae implantation using three and four sutures was modeled under three clinically relevant prolapse conditions: isolated P2, multi-scallop P2/P3, and multi-scallop P2/P1. A fluid-structure interaction (FSI) modeling framework was used to evaluate the left heart dynamics under baseline, prerepair, and postrepair states. Despite immediate restoration of leaflet coaptation and no residual mitral regurgitation in all postrepair models, the average and peak stresses in the repaired scallop(s) increased >40% and >100%, respectively, compared with the baseline state. Additionally, anterior mitral leaflet marginal chordae tension increased >30%, while posterior mitral leaflet chordae tension decreased at least 30%. No marked differences in hemodynamic performance, in native and neochordae forces, and in leaflet stress were found when implanting three or four sutures. We report, to our knowledge, the first set of time-dependent in silico FSI human neochordae tension measurements during transapical neochordae repair. This work represents a further step towards an improved understanding of the biomechanical outcomes of minimally invasive mitral valve repair procedures.
Collapse
Affiliation(s)
- Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | - Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | - Raymond McKay
- Division of Cardiology, The Hartford Hospital, Hartford, Connecticut
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| |
Collapse
|
11
|
Imbrie-Moore AM, Paulsen MJ, Zhu Y, Wang H, Lucian HJ, Farry JM, MacArthur JW, Ma M, Woo YJ. A novel cross-species model of Barlow's disease to biomechanically analyze repair techniques in an ex vivo left heart simulator. J Thorac Cardiovasc Surg 2020; 161:1776-1783. [PMID: 32249088 DOI: 10.1016/j.jtcvs.2020.01.086] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/17/2019] [Accepted: 01/02/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVE Barlow's disease remains challenging to repair, given the complex valvular morphology and lack of quantitative data to compare techniques. Although there have been recent strides in ex vivo evaluation of cardiac mechanics, to our knowledge, there is no disease model that accurately simulates the morphology and pathophysiology of Barlow's disease. The purpose of this study was to design such a model. METHODS To simulate Barlow's disease, a cross-species ex vivo model was developed. Bovine mitral valves (n = 4) were sewn into a porcine annulus mount to create excess leaflet tissue and elongated chordae. A heart simulator generated physiologic conditions while hemodynamic data, high-speed videography, and chordal force measurements were collected. The regurgitant valves were repaired using nonresectional repair techniques such as neochord placement. RESULTS The model successfully imitated the complexities of Barlow's disease, including redundant, billowing bileaflet tissues with notable regurgitation. After repair, hemodynamic data confirmed reduction of mitral leakage volume (25.9 ± 2.9 vs 2.1 ± 1.8 mL, P < .001) and strain gauge analysis revealed lower primary chordae forces (0.51 ± 0.17 vs 0.10 ± 0.05 N, P < .001). In addition, the maximum rate of change of force was significantly lower postrepair for both primary (30.80 ± 11.38 vs 8.59 ± 4.83 N/s, P < .001) and secondary chordae (33.52 ± 10.59 vs 19.07 ± 7.00 N/s, P = .006). CONCLUSIONS This study provides insight into the biomechanics of Barlow's disease, including sharply fluctuating force profiles experienced by elongated chordae prerepair, as well as restoration of primary chordae forces postrepair. Our disease model facilitates further in-depth analyses to optimize the repair of Barlow's disease.
Collapse
Affiliation(s)
- Annabel M Imbrie-Moore
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif; Department of Mechanical Engineering, Stanford University, Stanford, Calif
| | - Michael J Paulsen
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Yuanjia Zhu
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif; Department of Bioengineering, Stanford University, Stanford, Calif
| | - Hanjay Wang
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Haley J Lucian
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Justin M Farry
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - John W MacArthur
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Michael Ma
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif
| | - Y Joseph Woo
- Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif; Department of Bioengineering, Stanford University, Stanford, Calif.
| |
Collapse
|
12
|
Robbins AB, Freed AD, Moreno MR. Characterizing the non-linear mechanical behavior of native and biomimetic engineered tissues in 1D with physically meaningful parameters. J Mech Behav Biomed Mater 2020; 102:103509. [DOI: 10.1016/j.jmbbm.2019.103509] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 10/16/2019] [Accepted: 10/23/2019] [Indexed: 01/06/2023]
|
13
|
Salinas SD, Clark MM, Amini R. The effects of -80 °C short-term storage on the mechanical response of tricuspid valve leaflets. J Biomech 2020; 98:109462. [PMID: 31718820 DOI: 10.1016/j.jbiomech.2019.109462] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 10/23/2019] [Accepted: 10/24/2019] [Indexed: 11/19/2022]
Abstract
Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to freezing could be tissue-dependent. Prior to our study, however, such information was not available for the tricuspid valve leaflets. As such, for the first time, we examined whether fresh porcine specimens tested in a biaxial tensile machine would offer comparable results after being frozen at -80 °C. The stress-strain response of the tricuspid valve leaflets displayed no major deviation of the post-frozen leaflets as compared to fresh leaflets. We further compared the radial and circumferential strains as an indicator of deformation at similar stress states in fresh and thawed tissues, and we did not find any significant differences. Ice formation within the extra cellular matrix may modify the collagen fiber configuration, resulting in a slight change in the mechanical response. Nevertheless, our results indicated such a small deviation was negligible, thus enabling the possibility of using frozen porcine tricuspid valve specimens for future research.
Collapse
Affiliation(s)
- Samuel D Salinas
- Department of Biomedical Engineering, The University of Akron, Akron, Ohio, United States.
| | - Margaret M Clark
- Department of Biomedical Engineering, The University of Akron, Akron, Ohio, United States.
| | - Rouzbeh Amini
- Department of Biomedical Engineering, The University of Akron, Akron, Ohio, United States.
| |
Collapse
|
14
|
Duginski GA, Ross CJ, Laurence DW, Johns CH, Lee CH. An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets. J Mech Behav Biomed Mater 2019; 101:103438. [PMID: 31542570 PMCID: PMC8008703 DOI: 10.1016/j.jmbbm.2019.103438] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 07/27/2019] [Accepted: 09/15/2019] [Indexed: 01/03/2023]
Abstract
The atrioventricular heart valve (AHV) leaflets are critical to the facilitation of proper unidirectional blood flow through the heart. Previously, studies have been conducted to understand the tissue mechanics of healthy AHV leaflets to inform the development of valve-specific computational models and replacement materials for use in diagnosing and treating valvular heart disease. Generally, these studies involved biaxial mechanical testing of the AHV leaflet tissue specimens to extract relevant mechanical properties. Most of those studies considered freezing-based storage systems based on previous findings for other connective tissues such as aortic tissue or skin. However, there remains no study that specifically examines the effects of freezing storage on the characterized mechanical properties of the AHV leaflets. In this study, we aimed to address this gap in knowledge by performing biaxial mechanical characterizations of the tricuspid valve anterior leaflet (TVAL) tissue both before and after a 48-h freezing period. Primary findings of this study include: (i) a statistically insignificant change in the tissue extensibilities, with the frozen tissues being slightly stiffer and more anisotropic than the fresh tissues; and (ii) minimal variations in the stress relaxation behaviors between the fresh and frozen tissues, with the frozen tissues demonstrating slightly lessened relaxation. The findings from this study suggested that freezing-based storage does not significantly impact the observed mechanical properties of one of the five AHV leaflets-the TVAL. The results from this study are useful for reaffirming the experimental methodologies in the previous studies, as well as informing the tissue preservation methods of future investigations of AHV leaflet mechanics.
Collapse
Affiliation(s)
- Grace A Duginski
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA.
| | - Colton J Ross
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA.
| | - Devin W Laurence
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA.
| | - Cortland H Johns
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA.
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA; Institute for Biomedical Engineering, Science and Technology, School of Aerospace and Mechanical Engineering (IBEST), The University of Oklahoma, Norman, OK, 73019, USA.
| |
Collapse
|
15
|
Kramer KE, Ross CJ, Laurence DW, Babu AR, Wu Y, Towner RA, Mir A, Burkhart HM, Holzapfel GA, Lee CH. An investigation of layer-specific tissue biomechanics of porcine atrioventricular valve anterior leaflets. Acta Biomater 2019; 96:368-384. [PMID: 31260822 PMCID: PMC6717680 DOI: 10.1016/j.actbio.2019.06.049] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 06/24/2019] [Accepted: 06/26/2019] [Indexed: 12/29/2022]
Abstract
Atrioventricular heart valves (AHVs) are composed of structurally complex and morphologically heterogeneous leaflets. The coaptation of these leaflets during the cardiac cycle facilitates unidirectional blood flow. Valve regurgitation is treated preferably by surgical repair if possible or replacement based on the disease state of the valve tissue. A comprehensive understanding of valvular morphology and mechanical properties is crucial to refining computational models, serving as a patient-specific diagnostic and surgical tool for preoperative planning. Previous studies have modeled the stress distribution throughout the leaflet's thickness, but validations with layer-specific biaxial mechanical experiments are missing. In this study, we sought to fill this gap in literature by investigating the impact of microstructure constituents on mechanical behavior throughout the thickness of the AHVs' anterior leaflets. Porcine mitral valve anterior leaflets (MVAL) and tricuspid valve anterior leaflets (TVAL) were micro-dissected into three layers (atrialis/spongiosa, fibrosa, and ventricular) and two layers (atrialis/spongiosa and fibrosa/ventricularis), respectively, based on their relative distributions of extracellular matrix components as quantified by histological analyses: collagen, elastin, and glycosaminoglycans. Our results suggest that (i) for both valves, the atrialis/spongiosa layer is the most extensible and anisotropic layer, possibly due to its relatively low collagen content as compared to other layers, (ii) the intact TVAL response is stiffer than the atrialis/spongiosa layer but more compliant than the fibrosa/ventricularis layer, and (iii) the MVAL fibrosa and ventricularis layers behave nearly isotropic. These novel findings emphasize the biomechanical variances throughout the AHV leaflets, and our results could better inform future AHV computational model developments. STATEMENT OF SIGNIFICANCE: This study, which is the first of its kind for atrioventricular heart valve (AHV) leaflet tissue layers, rendered a mechanical characterization of the biaxial mechanical properties and distributions of extracellular matrix components (collagen, elastin, and glycosaminoglycans) of the mitral and tricuspid valve anterior leaflet layers. The novel findings from the present study emphasize the biomechanical variances throughout the thickness of AHV leaflets, and our results indicate that the previously-adopted homogenous leaflet in the AHV biomechanical modeling may be an oversimplification of the complex leaflet anatomy. Such improvement in the understanding of valvular morphology and tissue mechanics is crucial to future refinement of AHV computational models, serving as a patient-specific diagnostic and surgical tool, at the preoperative stage, for treating valvular heart diseases.
Collapse
Affiliation(s)
- Katherine E Kramer
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Colton J Ross
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Devin W Laurence
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Anju R Babu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Rheal A Towner
- Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation, Oklahoma City, OK 73104, USA
| | - Arshid Mir
- Division of Pediatric Cardiology, Department of Pediatrics, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Harold M Burkhart
- Division of Cardiothoracic Surgery, Department of Surgery, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, Norman, OK 73019, USA.
| |
Collapse
|
16
|
Vekilov DP, Singh M, Aglyamov SR, Larin KV, Grande-Allen KJ. Mapping the spatial variation of mitral valve elastic properties using air-pulse optical coherence elastography. J Biomech 2019; 93:52-59. [PMID: 31300156 PMCID: PMC10575695 DOI: 10.1016/j.jbiomech.2019.06.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/18/2019] [Accepted: 06/14/2019] [Indexed: 10/26/2022]
Abstract
The mitral valve is a highly heterogeneous tissue composed of two leaflets, anterior and posterior, whose unique composition and regional differences in material properties are essential to overall valve function. While mitral valve mechanics have been studied for many decades, traditional testing methods limit the spatial resolution of measurements and can be destructive. Optical coherence elastography (OCE) is an emerging method for measuring viscoelastic properties of tissues in a noninvasive, nondestructive manner. In this study, we employed air-pulse OCE to measure the spatial variation in mitral valve elastic properties with micro-scale resolution at 1 mm increments along the radial length of the leaflets. We analyzed differences between the leaflets, as well as between regions of the valve. We found that the anterior leaflet has a higher elastic wave velocity, which is reported as a surrogate for stiffness, than the posterior leaflet, most notably at the annular edge of the sample. In addition, we found a spatial elastic gradient in the anterior leaflet, where the annular edge was found to have a greater elastic wave velocity than the free edge. This gradient was less pronounced in the posterior leaflet. These patterns were confirmed using established uniaxial tensile testing methods. Overall, the anterior leaflet was stiffer and had greater heterogeneity in its mechanical properties than the posterior leaflet. This study measures differences between the two mitral leaflets with greater resolution than previously feasible and demonstrates a method that may be suitable for assessing valve mechanics following repair or during the engineering of synthetic valve replacements.
Collapse
Affiliation(s)
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, TX, United States
| | - Salavat R Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, TX, United States; University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, United States
| | - Kirill V Larin
- University of Houston, Department of Biomedical Engineering, Houston, TX, United States
| | | |
Collapse
|
17
|
Ross C, Laurence D, Wu Y, Lee CH. Biaxial Mechanical Characterizations of Atrioventricular Heart Valves. J Vis Exp 2019. [PMID: 31033941 PMCID: PMC8008701 DOI: 10.3791/59170] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Extensive biaxial mechanical testing of the atrioventricular heart valve leaflets can be utilized to derive optimal parameters used in constitutive models, which provide a mathematical representation of the mechanical function of those structures. This presented biaxial mechanical testing protocol involves (i) tissue acquisition, (ii) the preparation of tissue specimens, (iii) biaxial mechanical testing, and (iv) postprocessing of the acquired data. First, tissue acquisition requires obtaining porcine or ovine hearts from a local Food and Drug Administration-approved abattoir for later dissection to retrieve the valve leaflets. Second, tissue preparation requires using tissue specimen cutters on the leaflet tissue to extract a clear zone for testing. Third, biaxial mechanical testing of the leaflet specimen requires the use of a commercial biaxial mechanical tester, which consists of force-controlled, displacement-controlled, and stress-relaxation testing protocols to characterize the leaflet tissue's mechanical properties. Finally, post-processing requires the use of data image correlation techniques and force and displacement readings to summarize the tissue's mechanical behaviors in response to external loading. In general, results from biaxial testing demonstrate that the leaflet tissues yield a nonlinear, anisotropic mechanical response. The presented biaxial testing procedure is advantageous to other methods since the method presented here allows for a more comprehensive characterization of the valve leaflet tissue under one unified testing scheme, as opposed to separate testing protocols on different tissue specimens. The proposed testing method has its limitations in that shear stress is potentially present in the tissue sample. However, any potential shear is presumed negligible.
Collapse
Affiliation(s)
- Colton Ross
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Devin Laurence
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma; Institute for Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma;
| |
Collapse
|
18
|
Imbrie-Moore AM, Paulsen MJ, Thakore AD, Wang H, Hironaka CE, Lucian HJ, Farry JM, Edwards BB, Bae JH, Cutkosky MR, Woo YJ. Ex Vivo Biomechanical Study of Apical Versus Papillary Neochord Anchoring for Mitral Regurgitation. Ann Thorac Surg 2019; 108:90-97. [PMID: 30836099 DOI: 10.1016/j.athoracsur.2019.01.053] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Revised: 01/07/2019] [Accepted: 01/21/2019] [Indexed: 11/27/2022]
Abstract
BACKGROUND Neochordoplasty is an important repair technique, but optimal anchoring position is unknown. Although typically anchored at papillary muscles, new percutaneous devices anchor the neochordae at or near the ventricular apex, which may have an effect on chordal forces and the long-term durability of the repair. METHODS Porcine mitral valves (n = 6) were mounted in a left heart simulator that generates physiologic pressure and flow through the valves, and chordal forces were measured with Fiber Bragg Grating strain gauge sensors. Isolated mitral regurgitation was induced by cutting P2 primary chordae, and the regurgitant valve was repaired with polytetrafluoroethylene neochord with apical anchoring, followed by papillary muscle fixation for comparison. In both situations, the neochord was anchored to a customized force-sensing post positioned to mimic the relevant in vivo placement. RESULTS Echocardiographic and hemodynamic data confirmed that the repairs restored physiologic hemodynamics. Forces on the chordae and neochord were lower for papillary fixation than for the apical fixation (p = 0.003). In addition, the maximum rate of change of force on the chordae and neochordae was higher for apical fixation than for papillary fixation (p = 0.028). CONCLUSIONS Apical neochord anchoring results in effective repair of mitral regurgitation, albeit with somewhat higher forces on the chordae and neochord suture, as well as an increased rate of loading on the neochord compared with the papillary muscle fixation. These results may guide strategies to reduce stresses on neochordae as well as aid optimal patient selection.
Collapse
Affiliation(s)
- Annabel M Imbrie-Moore
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California; Department of Mechanical Engineering, Stanford University, Stanford, California
| | - Michael J Paulsen
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Akshara D Thakore
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Hanjay Wang
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Camille E Hironaka
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Haley J Lucian
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Justin M Farry
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Bryan B Edwards
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California
| | - Jung Hwa Bae
- Department of Mechanical Engineering, Stanford University, Stanford, California
| | - Mark R Cutkosky
- Department of Mechanical Engineering, Stanford University, Stanford, California
| | - Y Joseph Woo
- Department of Cardiothoracic Surgery, Stanford University, Stanford, California; Department of Bioengineering, Stanford University, Stanford, California.
| |
Collapse
|
19
|
Fatemifar F, Feldman MD, Oglesby M, Han HC. Comparison of Biomechanical Properties and Microstructure of Trabeculae Carneae, Papillary Muscles, and Myocardium in the Human Heart. J Biomech Eng 2019; 141:021007. [PMID: 30418486 PMCID: PMC6298537 DOI: 10.1115/1.4041966] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Revised: 10/28/2018] [Indexed: 12/13/2022]
Abstract
Trabeculae carneae account for a significant portion of human ventricular mass, despite being considered embryologic remnants. Recent studies have found trabeculae hypertrophy and fibrosis in hypertrophied left ventricles with various pathological conditions. The objective of this study was to investigate the passive mechanical properties and microstructural characteristics of trabeculae carneae and papillary muscles compared to the myocardium in human hearts. Uniaxial tensile tests were performed on samples of trabeculae carneae and myocardium strips, while biaxial tensile tests were performed on samples of papillary muscles and myocardium sheets. The experimental data were fitted with a Fung-type strain energy function and material coefficients were determined. The secant moduli at given diastolic stress and strain levels were determined and compared among the tissues. Following the mechanical testing, histology examinations were performed to investigate the microstructural characteristics of the tissues. Our results demonstrated that the trabeculae carneae were significantly stiffer (Secant modulus SM2 = 80.06 ± 10.04 KPa) and had higher collagen content (16.10 ± 3.80%) than the myocardium (SM2 = 55.14 ± 20.49 KPa, collagen content = 10.06 ± 4.15%) in the left ventricle. The results of this study improve our understanding of the contribution of trabeculae carneae to left ventricular compliance and will be useful for building accurate computational models of the human heart.
Collapse
Affiliation(s)
- Fatemeh Fatemifar
- Department of Mechanical Engineering,
University of Texas at San Antonio,
San Antonio, TX 78249
| | - Marc D. Feldman
- Department of Medicine,
University of Texas Health Science
Center at San Antonio,
San Antonio, TX 78229
| | - Meagan Oglesby
- Department of Medicine,
University of Texas Health Science
Center at San Antonio,
San Antonio, TX 78229
| | - Hai-Chao Han
- Department of Mechanical Engineering,
University of Texas at San Antonio,
San Antonio, TX 78249
e-mail:
| |
Collapse
|
20
|
Caballero A, Mao W, McKay R, Primiano C, Hashim S, Sun W. New insights into mitral heart valve prolapse after chordae rupture through fluid-structure interaction computational modeling. Sci Rep 2018; 8:17306. [PMID: 30470812 PMCID: PMC6251907 DOI: 10.1038/s41598-018-35555-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 11/07/2018] [Indexed: 12/19/2022] Open
Abstract
Mitral valve (MV) dynamics depends on a force balance across the mitral leaflets, the chordae tendineae, the mitral annulus, the papillary muscles and the adjacent ventricular wall. Chordae rupture disrupts the link between the MV and the left ventricle (LV), causing mitral regurgitation (MR), the most common valvular disease. In this study, a fluid-structure interaction (FSI) modeling framework is implemented to investigate the impact of chordae rupture on the left heart (LH) dynamics and severity of MR. A control and seven chordae rupture LH models were developed to simulate a pathological process in which minimal chordae rupture precedes more extensive chordae rupture. Different non-eccentric and eccentric regurgitant jets were identified during systole. Cardiac efficiency was evaluated by the ratio of external stroke work. MV structural results showed that basal/strut chordae were the major load-bearing chordae. An increased number of ruptured chordae resulted in reduced basal/strut tension, but increased marginal/intermediate load. Chordae rupture in a specific scallop did not necessarily involve an increase in the stress of the entire prolapsed leaflet. This work represents a further step towards patient-specific modeling of pathological LH dynamics, and has the potential to improve our understanding of the biomechanical mechanisms and treatment of primary MR.
Collapse
Affiliation(s)
- Andrés Caballero
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Wenbin Mao
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Raymond McKay
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Charles Primiano
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Sabet Hashim
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Wei Sun
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.
| |
Collapse
|
21
|
Basu A, Lacerda C, He Z. Mechanical Properties and Composition of the Basal Leaflet-Annulus Region of the Tricuspid Valve. Cardiovasc Eng Technol 2018; 9:217-225. [DOI: 10.1007/s13239-018-0343-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 02/19/2018] [Indexed: 10/17/2022]
|
22
|
Gao H, Qi N, Feng L, Ma X, Danton M, Berry C, Luo X. Modelling mitral valvular dynamics-current trend and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2858. [PMID: 27935265 PMCID: PMC5697636 DOI: 10.1002/cnm.2858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/30/2016] [Accepted: 11/26/2016] [Indexed: 05/19/2023]
Abstract
Dysfunction of mitral valve causes morbidity and premature mortality and remains a leading medical problem worldwide. Computational modelling aims to understand the biomechanics of human mitral valve and could lead to the development of new treatment, prevention and diagnosis of mitral valve diseases. Compared with the aortic valve, the mitral valve has been much less studied owing to its highly complex structure and strong interaction with the blood flow and the ventricles. However, the interest in mitral valve modelling is growing, and the sophistication level is increasing with the advanced development of computational technology and imaging tools. This review summarises the state-of-the-art modelling of the mitral valve, including static and dynamics models, models with fluid-structure interaction, and models with the left ventricle interaction. Challenges and future directions are also discussed.
Collapse
Affiliation(s)
- Hao Gao
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Nan Qi
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Liuyang Feng
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | | | - Mark Danton
- Department of Cardiac SurgeryRoyal Hospital for ChildrenGlasgowUK
| | - Colin Berry
- Institute of Cardiovascular and Medical SciencesUniversity of GlasgowUK
| | - Xiaoyu Luo
- School of Mathematics and StatisticsUniversity of GlasgowUK
| |
Collapse
|
23
|
Mao W, Caballero A, McKay R, Primiano C, Sun W. Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model. PLoS One 2017; 12:e0184729. [PMID: 28886196 PMCID: PMC5590990 DOI: 10.1371/journal.pone.0184729] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 08/29/2017] [Indexed: 12/17/2022] Open
Abstract
In this study, we present a fully-coupled fluid-structure interaction (FSI) framework that combines smoothed particle hydrodynamics (SPH) and nonlinear finite element (FE) method to investigate the coupled aortic and mitral valves structural response and the bulk intraventricular hemodynamics in a realistic left ventricle (LV) model during the entire cardiac cycle. The FSI model incorporates valve structures that consider native asymmetric leaflet geometries, anisotropic hyperelastic material models and human material properties. Comparison of FSI results with subject-specific echocardiography data demonstrates that the SPH-FE approach is able to quantitatively predict the opening and closing times of the valves, the mitral leaflet opening and closing angles, and the large-scale intraventricular flow phenomena with a reasonable agreement. Moreover, comparison of FSI results with a LV model without valves reveals substantial differences in the flow field. Peak systolic velocities obtained from the FSI model and the LV model without valves are 2.56 m/s and 1.16 m/s, respectively, compared to the Doppler echo data of 2.17 m/s. The proposed SPH-FE FSI framework represents a further step towards modeling patient-specific coupled LV-valve dynamics, and has the potential to improve our understanding of cardiovascular physiology and to support professionals in clinical decision-making.
Collapse
Affiliation(s)
- Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| | - Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| | - Raymond McKay
- Cardiology Department, The Hartford Hospital, Hartford, Connecticut, United States of America
| | - Charles Primiano
- Cardiology Department, The Hartford Hospital, Hartford, Connecticut, United States of America
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| |
Collapse
|
24
|
Kubíková T, Kochová P, Brázdil J, Špatenka J, Burkert J, Králíčková M, Tonar Z. The composition and biomechanical properties of human cryopreserved aortas, pulmonary trunks, and aortic and pulmonary cusps. Ann Anat 2017; 212:17-26. [DOI: 10.1016/j.aanat.2017.03.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 01/06/2017] [Accepted: 03/21/2017] [Indexed: 11/26/2022]
|
25
|
Aleman J, Adkins A, Boies L, Al-Quiati F, Sako E, Bhattacharya S. Effects of Cinching Force on the Tricuspid Annulus: A Species Comparison. JOURNAL OF CARDIOVASCULAR DISEASES & DIAGNOSIS 2017; 5:283. [PMID: 29911126 PMCID: PMC6002154 DOI: 10.4172/2329-9517.1000283] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
PURPOSE Tricuspid annuloplasty rings are commonly used to cinch an enlarged tricuspid annulus back to its original shape and size in patients with severe functional tricuspid regurgitation. However, the invasive operation is contraindicated for patients at risk for reoperation. Fortunately, transcatheter repair procedures, currently in the development process, are minimally invasive alternatives to current repair techniques. This study aims to determine the species-dependence of cinching force with the potential of informing transcatheter repair design by quantifying the minimum required cinching force necessary to reduce tricuspid regurgitation. METHODS The cinching force necessary to reduce the septal-lateral diameter of a dilated annuls was quantified and compared in ten ovine hearts and nine porcine hearts. Additionally, a deparaffinization protocol and Verhoeff-Van Gieson stain were used to compare the microscopic structure of tissue samples at different stages of the experimental procedure in the two species. RESULTS The maximum annulus dilation observed for the porcine was 11.2%, and the maximum cinching force was 0.40 ± 0.12 N. As previously demonstrated, ovine hearts yielded a maximum annulus dilation and cinching force of 8.82% and 0.38 ± 0.09 N respectively. Histological stains revealed no gross tissue differences between ovine and porcine septal or free wall tissues. CONCLUSION The cinching force was not species dependent between ovine and porcine models. This study is an essential first step for determining which animal model should be utilized for the development of transcatheter devices.
Collapse
Affiliation(s)
- Jesus Aleman
- School of Science, Engineering, and Technology, St. Mary’s University, 1 Camino Santa Maria, San Antonio, Texas, USA
| | - Amy Adkins
- School of Science, Engineering, and Technology, St. Mary’s University, 1 Camino Santa Maria, San Antonio, Texas, USA
| | - Lori Boies
- School of Science, Engineering, and Technology, St. Mary’s University, 1 Camino Santa Maria, San Antonio, Texas, USA
| | - Fatima Al-Quiati
- School of Science, Engineering, and Technology, St. Mary’s University, 1 Camino Santa Maria, San Antonio, Texas, USA
| | - Edward Sako
- Department of Cardiothoracic Surgery, University of Texas Health Science Center, San Antonio, Texas, USA
| | - Shamik Bhattacharya
- School of Science, Engineering, and Technology, St. Mary’s University, 1 Camino Santa Maria, San Antonio, Texas, USA
| |
Collapse
|
26
|
Quantification and comparison of the mechanical properties of four human cardiac valves. Acta Biomater 2017; 54:345-355. [PMID: 28336153 DOI: 10.1016/j.actbio.2017.03.026] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 02/21/2017] [Accepted: 03/16/2017] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. METHODS A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. RESULTS The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). CONCLUSIONS Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. STATEMENT OF SIGNIFICANCE Most research on heart valve mechanics have been conducted mainly on mitral and aortic valves or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same relatively healthy elderly patient population. In this study, the mechanical and microstructural properties of 114 leaflets of aortic, mitral, pulmonary and tricuspid valves from 12 human cadaver hearts were mechanically tested, analyzed and compared. Our results not only provided a baseline quantification of the mechanical properties of aged human valves, but a age range between patients (51-87years) also offers a better understanding of the age-dependent differences among the four valves. It is hoped that the obtained experimental data and associated constitutive parameters can facilitate studies of valve diseases, treatments and the development of interventional devices.
Collapse
|
27
|
Brinkman EL, Weed BC, Patnaik SS, Brazile BL, Centini RM, Wills RW, Olivier B, Sledge DG, Cooley J, Liao J, Rashmir-Raven AM. Cardiac findings in Quarter Horses with heritable equine regional dermal asthenia. J Am Vet Med Assoc 2017; 250:538-547. [DOI: 10.2460/javma.250.5.538] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
28
|
Khalighi AH, Drach A, Bloodworth CH, Pierce EL, Yoganathan AP, Gorman RC, Gorman JH, Sacks MS. Mitral Valve Chordae Tendineae: Topological and Geometrical Characterization. Ann Biomed Eng 2017; 45:378-393. [PMID: 27995395 PMCID: PMC7077931 DOI: 10.1007/s10439-016-1775-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2016] [Accepted: 12/07/2016] [Indexed: 01/27/2023]
Abstract
Mitral valve (MV) closure depends upon the proper function of each component of the valve apparatus, which includes the annulus, leaflets, and chordae tendineae (CT). Geometry plays a major role in MV mechanics and thus highly impacts the accuracy of computational models simulating MV function and repair. While the physiological geometry of the leaflets and annulus have been previously investigated, little effort has been made to quantitatively and objectively describe CT geometry. The CT constitute a fibrous tendon-like structure projecting from the papillary muscles (PMs) to the leaflets, thereby evenly distributing the loads placed on the MV during closure. Because CT play a major role in determining the shape and stress state of the MV as a whole, their geometry must be well characterized. In the present work, a novel and comprehensive investigation of MV CT geometry was performed to more fully quantify CT anatomy. In vitro micro-tomography 3D images of ovine MVs were acquired, segmented, then analyzed using a curve-skeleton transform. The resulting data was used to construct B-spline geometric representations of the CT structures, enriched with a continuous field of cross-sectional area (CSA) data. Next, Reeb graph models were developed to analyze overall topological patterns, along with dimensional attributes such as segment lengths, 3D orientations, and CSA. Reeb graph results revealed that the topology of ovine MV CT followed a full binary tree structure. Moreover, individual chords are mostly planar geometries that together form a 3D load-bearing support for the MV leaflets. We further demonstrated that, unlike flow-based branching patterns, while individual CT branches became thinner as they propagated further away from the PM heads towards the leaflets, the total CSA almost doubled. Overall, our findings indicate a certain level of regularity in structure, and suggest that population-based MV CT geometric models can be generated to improve current MV repair procedures.
Collapse
Affiliation(s)
- Amir H Khalighi
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
| | - Andrew Drach
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
| | - Charles H Bloodworth
- Cardiovascular Fluid Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Eric L Pierce
- Cardiovascular Fluid Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Ajit P Yoganathan
- Cardiovascular Fluid Mechanics Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Robert C Gorman
- Gorman Cardiovascular Research Group, Department of Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph H Gorman
- Gorman Cardiovascular Research Group, Department of Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Michael S Sacks
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
29
|
Pham T, Kong F, Martin C, Wang Q, Primiano C, McKay R, Elefteriades J, Sun W. Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation. Cardiovasc Eng Technol 2017; 8:3-16. [PMID: 28070866 DOI: 10.1007/s13239-016-0291-9] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 12/29/2016] [Indexed: 12/30/2022]
Abstract
Functional mitral regurgitation (FMR) is a significant complication of left ventricular dysfunction and strongly associated with a poor prognosis. In this study, we developed a patient-specific finite element (FE) model of the mitral apparatus in a FMR patient which included: both leaflets with thickness, annulus, chordae tendineae, and chordae insertions on the leaflets and origins on the papillary muscles. The FE model incorporated human age- and gender-matched anisotropic hyperelastic material properties, and MV closure at systole was simulated. The model was validated by comparing the FE results from valve closure simulation with the in vivo geometry of the MV at systole. It was found that the FE model could not replicate the in vivo MV geometry without the application of tethering pre-tension force in the chordae at diastole. Upon applying the pre-tension force and performing model optimization by adjusting the chordal length, position, and leaflet length, a good agreement between the FE model and the in vivo model was established. Not only were the chordal forces high at both diastole and systole, but the tethering force on the anterior papillary muscle was higher than that of the posterior papillary muscle, which resulted in an asymmetrical gap with a larger orifice area at the anterolateral commissure resulting in MR. The analyses further show that high peak stress and strain were found at the chordal insertions where large chordal tethering forces were found. This study shows that the pre-tension tethering force plays an important role in accurately simulating the MV dynamics in this FMR patient, particularly in quantifying the degree of leaflet coaptation and stress distribution. Due to the complexity of the disease, the patient-specific computational modeling procedure of FMR patients presented should be further evaluated using a large patient cohort. However, this study provides useful insights into the MV biomechanics of a FMR patient, and could serve as a tool to assist in pre-operative planning for MV repair or replacement surgical or interventional procedures.
Collapse
Affiliation(s)
- Thuy Pham
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Fanwei Kong
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Caitlin Martin
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Qian Wang
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | | | - Raymond McKay
- Cardiology Department of Hartford Hospital, Hartford, CT, USA
| | | | - Wei Sun
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Room 206, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
| |
Collapse
|
30
|
Zhang F, Kanik J, Mansi T, Voigt I, Sharma P, Ionasec RI, Subrahmanyan L, Lin BA, Sugeng L, Yuh D, Comaniciu D, Duncan J. Towards patient-specific modeling of mitral valve repair: 3D transesophageal echocardiography-derived parameter estimation. Med Image Anal 2017; 35:599-609. [DOI: 10.1016/j.media.2016.09.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 09/12/2016] [Accepted: 09/19/2016] [Indexed: 11/29/2022]
|
31
|
Popa MO, Irimia AM, Papagheorghe MN, Vasile EM, Tircol SA, Negulescu RA, Toader C, Adam R, Dorobantu L, Caldararu C, Alexandrescu M, Onciul S. The mechanisms, diagnosis and management of mitral regurgitation in mitral valve prolapse and hypertrophic cardiomyopathy. Discoveries (Craiova) 2016; 4:e61. [PMID: 32309580 PMCID: PMC7159827 DOI: 10.15190/d.2016.8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Valvular disease is a frequent cardiac pathology leading to heart failure and, ultimately, death. Mitral regurgitation, defined as the inability of the two mitral leaflets to coapt, is a common valvular disease and a self sustained pathology. A better understanding of the mitral valve histological layers provides a better understanding of the leaflet and chordae changes in mitral valve prolapse.
Mitral valve prolapse may occur in myxomatous degenerative abnormalities, connective tissue disorders or in sporadic isolated cases. It is the most common mitral abnormality of non-ischemic cause leading to severe surgery-requiring mitral regurgitation. In addition to standard echocardiographic investigations, newly implemented three-dimensional techniques are being used and they permit a better visualisation, from the so-called ‘surgical view’, and an improved evaluation of the mitral valve.
Hypertrophic cardiomyopathy is the most frequent inherited myocardial disease caused by mutations in various genes encoding proteins of the cardiac sarcomere, leading to a marked left ventricular hypertrophy unexplained by other comorbidities. The pathological echocardiographic hallmarks of hypertrophic cardiomyopathy are left ventricular hypertrophy, left ventricular outflow tract obstruction and systolic anterior motion of the mitral valve. The systolic anterior motion of the mitral valve contributes to the development of mitral regurgitation and further narrows the left ventricular outflow tract, leading to more severe symptomatology. Cardiac magnetic resonance imaging accurately measures the left ventricular mass, the degree of diastolic function and it may also be used to distinguish phenotypic variants.
The clinical outcome of patients with these pathologies is mostly determined by the selected option of treatment. The purpose of surgical correction regarding mitral valve involvement is to restore valvular competence. Surgery has proven to be the only useful treatment in preventing heart failure, improving symptomatology and reducing mortality. Our approach wishes to enhance the understanding of the mitral valve’s involvement in hypertrophic cardiomyopathy and mitral valve prolapse from genetic, haemodynamic and clinical perspectives, as well as to present novelties in the grand field of treatment.
Collapse
Affiliation(s)
| | - Ana Maria Irimia
- Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| | | | | | | | | | - Catalina Toader
- Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| | - Robert Adam
- Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| | - Lucian Dorobantu
- Department of Cardiovascular Surgery, Monza Hospital, Bucharest, Romania
| | | | - Maria Alexandrescu
- Department of Radiology and Imaging Sciences, Monza Hospital, Bucharest, Romania
| | - Sebastian Onciul
- Department of Cardiology, Floreasca Clinical Emergency Hospital, Bucharest, Romania
| |
Collapse
|
32
|
Levine RA, Hagége AA, Judge DP, Padala M, Dal-Bianco JP, Aikawa E, Beaudoin J, Bischoff J, Bouatia-Naji N, Bruneval P, Butcher JT, Carpentier A, Chaput M, Chester AH, Clusel C, Delling FN, Dietz HC, Dina C, Durst R, Fernandez-Friera L, Handschumacher MD, Jensen MO, Jeunemaitre XP, Le Marec H, Le Tourneau T, Markwald RR, Mérot J, Messas E, Milan DP, Neri T, Norris RA, Peal D, Perrocheau M, Probst V, Pucéat M, Rosenthal N, Solis J, Schott JJ, Schwammenthal E, Slaugenhaupt SA, Song JK, Yacoub MH. Mitral valve disease--morphology and mechanisms. Nat Rev Cardiol 2015; 12:689-710. [PMID: 26483167 DOI: 10.1038/nrcardio.2015.161] [Citation(s) in RCA: 253] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but--even in adult life--remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular-ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease.
Collapse
Affiliation(s)
- Robert A Levine
- Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Yawkey 5E, Boston, MA 02114, USA
| | - Albert A Hagége
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | | | | | - Jacob P Dal-Bianco
- Massachusetts General Hospital, Cardiac Ultrasound Laboratory, Harvard Medical School, Boston, MA, USA
| | | | | | | | - Nabila Bouatia-Naji
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | - Patrick Bruneval
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | | | - Alain Carpentier
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | | | | | | | - Francesca N Delling
- Beth Israel Deaconess Medical Centre, Harvard Medical School, Boston, MA, USA
| | | | - Christian Dina
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | - Ronen Durst
- Hadassah-Hebrew University Medical Centre, Jerusalem, Israel
| | - Leticia Fernandez-Friera
- Hospital Universitario HM Monteprincipe and the Centro Nacional de Investigaciones Cardiovasculares, Carlos III (CNIC), Madrid, Spain
| | - Mark D Handschumacher
- Massachusetts General Hospital, Cardiac Ultrasound Laboratory, Harvard Medical School, Boston, MA, USA
| | | | - Xavier P Jeunemaitre
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | - Hervé Le Marec
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | - Thierry Le Tourneau
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | | | - Jean Mérot
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | - Emmanuel Messas
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | - David P Milan
- Cardiovascular Research Center, Harvard Medical School, Boston, MA, USA
| | - Tui Neri
- Aix-Marseille University, INSERM UMR 910, Marseille, France
| | | | - David Peal
- Cardiovascular Research Center, Harvard Medical School, Boston, MA, USA
| | - Maelle Perrocheau
- Hôpital Européen Georges Pompidou, Université René Descartes, UMR 970, Paris, France
| | - Vincent Probst
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | - Michael Pucéat
- Aix-Marseille University, INSERM UMR 910, Marseille, France
| | | | - Jorge Solis
- Hospital Universitario HM Monteprincipe and the Centro Nacional de Investigaciones Cardiovasculares, Carlos III (CNIC), Madrid, Spain
| | - Jean-Jacques Schott
- University of Nantes, Thoracic Institute, INSERM UMR 1097, CNRS UMR 6291, Nantes, France
| | | | - Susan A Slaugenhaupt
- Center for Human Genetic Research, MGH Research Institute, Harvard Medical School, Boston, MA, USA
| | | | | | | |
Collapse
|
33
|
Functional and Biomechanical Effects of the Edge-to-Edge Repair in the Setting of Mitral Regurgitation: Consolidated Knowledge and Novel Tools to Gain Insight into Its Percutaneous Implementation. Cardiovasc Eng Technol 2014; 6:117-40. [PMID: 26577231 DOI: 10.1007/s13239-014-0208-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Accepted: 12/05/2014] [Indexed: 10/24/2022]
Abstract
Mitral regurgitation is the most prevalent heart valve disease in the western population. When severe, it requires surgical treatment, repair being the preferred option. The edge-to-edge repair technique treats mitral regurgitation by suturing the leaflets together and creating a double-orifice valve. Due to its relative simplicity and versatility, it has become progressively more widespread. Recently, its percutaneous version has become feasible, and has raised interest thanks to the positive results of the Mitraclip(®) device. Edge-to-edge features and evolution have stimulated debate and multidisciplinary research by both clinicians and engineers. After providing an overview of representative studies in the field, here we propose a novel computational approach to the most recent percutaneous evolution of the edge-to-edge technique. Image-based structural finite element models of three mitral valves affected by posterior prolapse were derived from cine-cardiac magnetic resonance imaging. The models accounted for the patient-specific 3D geometry of the valve, including leaflet compound curvature pattern, patient-specific motion of annulus and papillary muscles, and hyperelastic and anisotropic mechanical properties of tissues. The biomechanics of the three valves throughout the entire cardiac cycle was simulated before and after Mitraclip(®) implantation, assessing the biomechanical impact of the procedure. For all three simulated MVs, Mitraclip(®) implantation significantly improved systolic leaflets coaptation, without inducing major alterations in systolic peak stresses. Diastolic orifice area was decreased, by up to 58.9%, and leaflets diastolic stresses became comparable, although lower, to systolic ones. Despite established knowledge on the edge-to-edge surgical repair, latest technological advances make its percutanoues implementation a challenging field of research. The modeling approach herein proposed may be expanded to analyze clinical scenarios that are currently critical for Mitraclip(®) implantation, helping the search for possible solutions.
Collapse
|
34
|
Abstract
In the past two decades, major advances have been made in the clinical evaluation and treatment of valvular heart disease owing to the advent of noninvasive cardiac imaging modalities. In clinical practice, valvular disease evaluation is typically performed on two-dimensional (2D) images, even though most imaging modalities offer three-dimensional (3D) volumetric, time-resolved data. Such 3D data offer researchers the possibility to reconstruct the 3D geometry of heart valves at a patient-specific level. When these data are integrated with computational models, native heart valve biomechanical function can be investigated, and preoperative planning tools can be developed. In this review, we outline the advances in valve geometry reconstruction, tissue property modeling, and loading and boundary definitions for the purpose of realistic computational structural analysis of cardiac valve function and intervention.
Collapse
Affiliation(s)
- Wei Sun
- Tissue Mechanics Lab, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30313;
| | | | | |
Collapse
|
35
|
Bhattacharya S, Pham T, He Z, Sun W. Tension to passively cinch the mitral annulus through coronary sinus access: an ex vivo study in ovine model. J Biomech 2014; 47:1382-8. [PMID: 24607007 DOI: 10.1016/j.jbiomech.2014.01.044] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2013] [Revised: 01/22/2014] [Accepted: 01/23/2014] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The transcatheter mitral valve repair (TMVR) technique utilizes a stent to cinch a segment of the mitral annulus (MA) and reduces mitral regurgitation. The cinching mechanism results in reduction of the septal-lateral distance. However, the mechanism has not been characterized completely. In this study, a method was developed to quantify the relation between cinching tension and MA area in an ex vivo ovine model. METHOD The cinching tension was measured from a suture inserted within the coronary sinus (CS) vessel with one end tied to the distal end of the vessel and the other end exited to the CS ostium where it was attached to a force transducer on a linear stage. The cinching tension, MA area, septal-lateral (S-L) and commissure-commissure (C-C) diameters and leakage was simultaneously measured in normal and dilated condition, under a hydrostatic left ventricular pressure of 90 mm Hg. RESULTS The MA area was increased up to 22.8% after MA dilation. A mean tension of 2.1 ± 0.5 N reduced the MA area by 21.3 ± 5.6% and S-L diameter by 24.2 ± 5.3%. Thus, leakage was improved by 51.7 ± 16.2% following restoration of normal MA geometry. CONCLUSION The cinching tension generated by the suture acts as a compensation force in MA reduction, implying the maximum tension needed to be generated by annuloplasty device to restore normal annular size. The relationship between cinching tension and the corresponding MA geometry will contribute to the development of future TMVR devices and understanding of myocardial contraction function.
Collapse
Affiliation(s)
- Shamik Bhattacharya
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States
| | - Thuy Pham
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States
| | - Zhaoming He
- Department of Mechanical Engineering Texas Tech University, Lubbock, TX 79409, United States
| | - Wei Sun
- Tissue Mechanics Laboratory Biomedical Engineering Program and Department of Mechanical Engineering University of Connecticut, Storrs, CT 06269, United States.
| |
Collapse
|