1
|
Nikolić O, Nikolić MB, Pantelić M, Lukač S, Till V, Stojanović S, Molnar U. Compressed SENSE acceleration factor influence on magnetic resonance image quality in patients with endometrial cancer. Phys Med 2025; 130:104899. [PMID: 39823914 DOI: 10.1016/j.ejmp.2025.104899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 10/30/2024] [Accepted: 01/07/2025] [Indexed: 01/20/2025] Open
Abstract
OBJECTIVES To investigate the impact of compressed sensing - sensitivity encoding (CS-SENSE) acceleration factor on the diagnostic performance of magnetic resonance imaging (MRI) within standard female pelvis protocol in patients with endometrial cancer. METHODS T2-weighted turbo spin echo (TSE) sequence from standard female pelvic MRI protocol was chosen due to its long acquisition time and essential role in the evaluation of morphological characteristics of the female pelvic anatomical structures. Fully sampled reference scans and multiple prospectively 2x to 5x under-sampled CS-SENSE scans were acquired. Retrospectively, under-sampled scans were compared to fully sampled scans and visually assessed for image quality and diagnostic quality by two independent radiologists dedicated to urogenital imaging with different experience levels. RESULTS Images obtained with CS-SENSE accelerated acquisition were of diagnostically acceptable quality at up to 3x acceleration for T2 TSE in both axial and sagittal planes (with an acquisition time reduction of 64 %). Among all evaluated uterine structures, the junctional zone proved to be most sensitive to the influence of the acceleration factor. Statistical analysis showed statistically significant differences between image interpretation qualities between two radiologists of different experience levels (p < 0.05). CONCLUSION CS-SENSE accelerated T2 TSE sequence of the female pelvis shows image quality similar to that of conventional acquisitions with reduced acquisition time. CS-SENSE can moderately reduce scan time, providing many benefits without losing the image quality.
Collapse
Affiliation(s)
- Olivera Nikolić
- Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Marijana Basta Nikolić
- Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Miloš Pantelić
- Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Clinic for Gynecology and Obstetrics, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Sonja Lukač
- Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Viktor Till
- Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Sanja Stojanović
- Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia.
| | - Una Molnar
- Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovića 3, 21000 Novi Sad, Serbia.
| |
Collapse
|
2
|
Wang B, Lian Y, Xiong X, Han H, Liu Z. CRNN-Refined Spatiotemporal Transformer for Dynamic MRI reconstruction. Comput Biol Med 2024; 182:109133. [PMID: 39276614 DOI: 10.1016/j.compbiomed.2024.109133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Revised: 05/28/2024] [Accepted: 09/07/2024] [Indexed: 09/17/2024]
Abstract
Magnetic Resonance Imaging (MRI) plays a pivotal role in modern clinical practice, providing detailed anatomical visualization with exceptional spatial resolution and soft tissue contrast. Dynamic MRI, aiming to capture both spatial and temporal characteristics, faces challenges related to prolonged acquisition times and susceptibility to motion artifacts. Balancing spatial and temporal resolutions becomes crucial in real-world clinical scenarios. In the realm of dynamic MRI reconstruction, while Convolutional Recurrent Neural Networks (CRNNs) struggle with long-range dependencies, CRNNs require extensive iterations, impacting efficiency. Transformers, known for their effectiveness in high-dimensional imaging, are underexplored in dynamic MRI reconstruction. Additionally, prevailing algorithms fall short of achieving superior results in demanding generative reconstructions at high acceleration rates. This research proposes a novel approach for dynamic MRI reconstruction, named CRNN-Refined Spatiotemporal Transformer Network (CST-Net). The spatiotemporal Transformer initiates reconstruction, modeling temporal and spatial correlations, followed by refinement using the CRNN. This integration mitigates inaccuracies caused by damaged frames and reduces CRNN iterations, enhancing computational efficiency without compromising reconstruction quality. Our study compares the performance of the proposed CST-Net at 6 × and 12 × undersampling rates, showcasing its superiority over existing algorithms. Particularly, in challenging 25× generative reconstructions, the CST-Net outperforms current methods. The comparison includes experiments under both radial and Cartesian undersampling patterns. In conclusion, CST-Net successfully addresses the limitations inherent in existing generative reconstruction algorithms, thereby paving the way for further exploration and optimization of Transformer-based approaches in dynamic MRI reconstruction. Code and Datasets can be available: https://github.com/XWangBin/CST-Net.
Collapse
Affiliation(s)
- Bin Wang
- Center for Metrology Scientific Data, National Institute of Metrology, Beijing, 100029, China; Key Laboratory of Metrology Digitalization and Digital Metrology, State Administration for Market Regulation, Beijing, 100029, China; School of Printing and Packaging Engineering, Beijing Institute of Graphic Communication, Beijing, 102600, China.
| | - Yusheng Lian
- School of Printing and Packaging Engineering, Beijing Institute of Graphic Communication, Beijing, 102600, China.
| | - Xingchuang Xiong
- Center for Metrology Scientific Data, National Institute of Metrology, Beijing, 100029, China; Key Laboratory of Metrology Digitalization and Digital Metrology, State Administration for Market Regulation, Beijing, 100029, China.
| | - Hongbin Han
- Department of Radiology, Peking University Third Hospital. Institute of Medical Technology, Peking University Health Science Center. Beijing Key Laboratory of Magnetic Resonance Imaging Devices and Technology, Peking University Third Hospital, Beijing, 100191, China.
| | - Zilong Liu
- Center for Metrology Scientific Data, National Institute of Metrology, Beijing, 100029, China; Key Laboratory of Metrology Digitalization and Digital Metrology, State Administration for Market Regulation, Beijing, 100029, China.
| |
Collapse
|
3
|
Sjöberg P, Lala T, Wittgren J, Jin N, Hedström E, Töger J. Image reconstruction impacts haemodynamic parameters derived from 4D flow magnetic resonance imaging with compressed sensing. EUROPEAN HEART JOURNAL. IMAGING METHODS AND PRACTICE 2024; 2:qyae137. [PMID: 39776817 PMCID: PMC11705387 DOI: 10.1093/ehjimp/qyae137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 12/08/2024] [Indexed: 01/11/2025]
Abstract
Aims 4D blood flow measurements by cardiac magnetic resonance imaging (CMR) can be used to simplify blood flow assessment. Compressed sensing (CS) can provide better flow measurements than conventional parallel imaging (PI), but clinical validation is needed. This study aimed to validate stroke volume (SV) measurements by 4D-CS in healthy volunteers and patients while also investigating the influence of the CS image reconstruction parameter λ on haemodynamic parameters. Methods and results Healthy participants (n = 9; 20-62 years) underwent CMR with 2D, 4D-CS, and 4D-PI flow. Patients (n = 30, 17 with congenital heart defect; 2-75 years) had 4D-CS added to their clinical examination. Impact of λ was assessed by reconstructing 4D-CS data for six different λ values. In healthy volunteers, 4D-CS and 4D-PI SV differed by 0.4 ± 6.5 mL [0.6 ± 9.1%; intraclass correlation coefficient (ICC) 0.98], and 4D-CS and 2D flow by 0.9 ± 7.0 mL (0.9 ± 10.6%; ICC 0.98). In patients, 4D-CS and 2D flow differed by -1.3 ± 6.0 mL (-7.2 ± 20%; ICC 0.97). SV was not dependent on λ in patients (P = 0.75) but an increase in λ by 0.001 led to increased differences between 4D-CS and 4D-PI of -0.4% (P = 0.0021) in healthy participants. There were significant differences for ventricular kinetic energy (systole: P < 0.0001; diastole: P < 0.0001) and haemodynamic forces (systole: P < 0.0001; diastole: P < 0.0001), where error increased with increasing λ values in both healthy participants and patients. Conclusion 4D flow CMR with CS can be used clinically to assess SV in paediatric and adult patients. Ventricular kinetic energy and haemodynamic forces are however sensitive to the change in reconstruction parameter λ, and it is therefore important to validate advanced blood flow measurements before comparing data between scanners and centres.
Collapse
Affiliation(s)
- Pia Sjöberg
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden
- Department of Clinical Physiology, Skåne University Hospital, Lund 221 85, Sweden
| | - Tania Lala
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden
- Biomedical Engineering, Lund University, Lund, Sweden
| | - Johan Wittgren
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden
- Department of Clinical Physiology, Skåne University Hospital, Lund 221 85, Sweden
| | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Cleveland, OH, USA
| | - Erik Hedström
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden
- Department of Clinical Physiology, Skåne University Hospital, Lund 221 85, Sweden
- Diagnostic Radiology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
- Department of Radiology, Skåne University Hospital, Lund, Sweden
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Lund 221 00, Sweden
- Department of Clinical Physiology, Skåne University Hospital, Lund 221 85, Sweden
- Biomedical Engineering, Lund University, Lund, Sweden
| |
Collapse
|
4
|
Villegas-Martinez M, de Villedon de Naide V, Muthurangu V, Bustin A. The beating heart: artificial intelligence for cardiovascular application in the clinic. MAGMA (NEW YORK, N.Y.) 2024; 37:369-382. [PMID: 38907767 DOI: 10.1007/s10334-024-01180-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 04/25/2024] [Accepted: 06/13/2024] [Indexed: 06/24/2024]
Abstract
Artificial intelligence (AI) integration in cardiac magnetic resonance imaging presents new and exciting avenues for advancing patient care, automating post-processing tasks, and enhancing diagnostic precision and outcomes. The use of AI significantly streamlines the examination workflow through the reduction of acquisition and postprocessing durations, coupled with the automation of scan planning and acquisition parameters selection. This has led to a notable improvement in examination workflow efficiency, a reduction in operator variability, and an enhancement in overall image quality. Importantly, AI unlocks new possibilities to achieve spatial resolutions that were previously unattainable in patients. Furthermore, the potential for low-dose and contrast-agent-free imaging represents a stride toward safer and more patient-friendly diagnostic procedures. Beyond these benefits, AI facilitates precise risk stratification and prognosis evaluation by adeptly analysing extensive datasets. This comprehensive review article explores recent applications of AI in the realm of cardiac magnetic resonance imaging, offering insights into its transformative potential in the field.
Collapse
Affiliation(s)
- Manuel Villegas-Martinez
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Hôpital Xavier Arnozan, Université de Bordeaux-INSERM U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - Victor de Villedon de Naide
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Hôpital Xavier Arnozan, Université de Bordeaux-INSERM U1045, Avenue du Haut Lévêque, 33604, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - Vivek Muthurangu
- Center for Cardiovascular Imaging, UCL Institute of Cardiovascular Science, University College London, London, WC1N 1EH, UK
| | - Aurélien Bustin
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Hôpital Xavier Arnozan, Université de Bordeaux-INSERM U1045, Avenue du Haut Lévêque, 33604, Pessac, France.
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Avenue de Magellan, 33604, Pessac, France.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| |
Collapse
|
5
|
Ma P, Zhu L, Wen R, Lv F, Li Y, Li X, Zhang Z. Revolutionizing vascular imaging: trends and future directions of 4D flow MRI based on a 20-year bibliometric analysis. Quant Imaging Med Surg 2024; 14:1873-1890. [PMID: 38415143 PMCID: PMC10895087 DOI: 10.21037/qims-23-1227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 12/08/2023] [Indexed: 02/29/2024]
Abstract
Background Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a promising new technology with potential clinical value in hemodynamic quantification. Although an increasing number of articles on 4D flow MRI have been published over the past decades, few studies have statistically analyzed these published articles. In this study, we aimed to perform a systematic and comprehensive bibliometric analysis of 4D flow MRI to explore the current hotspots and potential future directions. Methods The Web of Science Core Collection searched for literature on 4D flow MRI between 2003 and 2022. CiteSpace was utilized to analyze the literature data, including co-citation, cooperative network, cluster, and burst keyword analysis. Results A total of 1,069 articles were extracted for this study. The main research hotspots included the following: quantification and visualization of blood flow in different clinical settings, with keywords such as "cerebral aneurysm", "heart", "great vessel", "tetralogy of Fallot", "portal hypertension", and "stiffness"; optimization of image acquisition schemes, such as "resolution" and "reconstruction"; measurement and analysis of flow components and patterns, as indicated by keywords "pattern", "KE", "WSS", and "fluid dynamics". In addition, international consensus for metrics derived from 4D flow MRI and multimodality imaging may also be the future research direction. Conclusions The global domain of 4D flow MRI has grown over the last 2 decades. In the future, 4D flow MRI will evolve towards becoming a relatively short scan duration with adequate spatiotemporal resolution, expansion into the diagnosis and treatment of vascular disease in other related organs, and a shift in focus from vascular structure to function. In addition, artificial intelligence (AI) will assist in the clinical promotion and application of 4D flow MRI.
Collapse
Affiliation(s)
- Peisong Ma
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Lishu Zhu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Ru Wen
- Department of Radiology, Guizhou Provincial People Hospital, Guiyang, China
| | - Fajin Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Yongmei Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xinyou Li
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhiwei Zhang
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
6
|
Ebrahimkhani M, Johnson EMI, Sodhi A, Robinson JD, Rigsby CK, Allen BD, Markl M. A Deep Learning Approach to Using Wearable Seismocardiography (SCG) for Diagnosing Aortic Valve Stenosis and Predicting Aortic Hemodynamics Obtained by 4D Flow MRI. Ann Biomed Eng 2023; 51:2802-2811. [PMID: 37573264 DOI: 10.1007/s10439-023-03342-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/27/2023] [Indexed: 08/14/2023]
Abstract
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.
Collapse
Affiliation(s)
- Mahmoud Ebrahimkhani
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Ethan M I Johnson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Aparna Sodhi
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
| | - Joshua D Robinson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Cynthia K Rigsby
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Bradly D Allen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA.
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
7
|
Ridderbos FJS, Chan FP, van Melle JP, Ebels T, Feinstein JA, Berger RMF, Willems TP. Quantification of systemic-to-pulmonary collateral flow in univentricular physiology with 4D flow MRI. Cardiol Young 2023; 33:1634-1642. [PMID: 36120930 DOI: 10.1017/s1047951122002840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE Systemic-to-pulmonary collateral flow is a well-recognised phenomenon in patients with single ventricle physiology, but remains difficult to quantify. The aim was to compare the reported formula's that have been used for calculation of systemic-to-pulmonary-collateral flow to assess their consistency and to quantify systemic-to-pulmonary collateral flow in patients with a Glenn and/or Fontan circulation using four-dimensional flow MRI (4D flow MR). METHODS Retrospective case-control study of Glenn and Fontan patients who had a 4D flow MR study. Flows were measured at the ascending aorta, left and right pulmonary arteries, left and right pulmonary veins, and both caval veins. Systemic-to-pulmonary collateral flow was calculated using two formulas: 1) pulmonary veins - pulmonary arteries and 2) ascending aorta - caval veins. Anatomical identification of collaterals was performed using the 4D MR image set. RESULTS Fourteen patients (n = 11 Fontan, n = 3 Glenn) were included (age 26 [22-30] years). Systemic-to-pulmonary collateral flow was significantly higher in the patients than the controls (n = 10, age 31.2 [15.1-38.4] years) with both formulas: 0.28 [0.09-0.5] versus 0.04 [-0.66-0.21] l/min/m2 (p = 0.036, formula 1) and 0.67 [0.24-0.88] versus -0.07 [-0.16-0.08] l/min/m2 (p < 0.001, formula 2). In patients, systemic-to-pulmonary collateral flow differed significantly between formulas 1 and 2 (13% versus 26% of aortic flow, p = 0.038). In seven patients, veno-venous collaterals were detected and no aortopulmonary collaterals were visualised. CONCLUSION 4D flow MR is able to detect increased systemic-to-pulmonary collateral flow and visualise collaterals vessels in Glenn and Fontan patients. However, the amount of systemic-to-pulmonary collateral flow varies with the formula employed. Therefore, further research is necessary before it could be applied in clinical care.
Collapse
Affiliation(s)
- Floris-Jan S Ridderbos
- Department of Radiology, Stanford University Medical Center, Stanford University, Stanford, USA
- Department of Pediatric Cardiology, Center for Congenital Heart Diseases, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Frandics P Chan
- Department of Radiology, Stanford University Medical Center, Stanford University, Stanford, USA
| | - Joost P van Melle
- Department of Cardiology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Tjark Ebels
- Department of Cardiothoracic Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
- Department of Cardiothoracic Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Jeffrey A Feinstein
- Department of Pediatrics (Cardiology), Stanford University Medical Center / Lucile Packard Children's Hospital, Stanford University, Stanford, USA
| | - Rolf M F Berger
- Department of Pediatric Cardiology, Center for Congenital Heart Diseases, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Tineke P Willems
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| |
Collapse
|
8
|
Soulat G, Alattar Y, Ladouceur M, Craiem D, Pascaner A, Gencer U, Malekzadeh-Milani S, Iserin L, Karsenty C, Mousseaux E. Discordance between 2D and 4D flow in the assessment of pulmonary regurgitation severity: a right ventricular remodeling follow-up study. Eur Radiol 2023; 33:5455-5464. [PMID: 36905468 DOI: 10.1007/s00330-023-09502-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 12/06/2022] [Accepted: 02/06/2023] [Indexed: 03/12/2023]
Abstract
OBJECTIVES Pulmonary regurgitation (PR) is common in adult congenital heart disease (ACHD). 2D phase contrast MRI is the reference method for the quantification of PR and helps in the decision of pulmonary valve replacement (PVR). 4D flow MRI can be an alternative method to estimate PR but more validation is still needed. Our purpose was to compare 2D and 4D flow in PR quantification using the degree of right ventricular remodeling after PVR as the reference standard. METHODS In 30 adult patients with a pulmonary valve disease recruited between 2015 and 2018, PR was assessed using both 2D and 4D flow. Based on the clinical standard of care, 22 underwent PVR. The pre PVR estimate of PR was compared using the post-operative decrease in right ventricle end-diastolic volume on follow-up exam as reference. RESULTS In the overall cohort, regurgitant volume (Rvol) and regurgitant fraction (RF) of PR measured by 2D and 4D flow were well correlated but with moderate agreement in the overall cohort (r = 0.90, mean diff. -14 ± 12.5 mL; and r = 0.72, mean diff. -15 ± 13%; all p < 0.0001). Correlations between Rvol estimates and right ventricle end-diastolic volume decrease after PVR was higher with 4D flow (r = 0.80, p < 0.0001) than with 2D flow (r = 0.72, p < 0.0001). CONCLUSIONS In ACHD, PR quantification from 4D flow better predicts post-PVR right ventricle remodeling than that from 2D flow. Further studies are needed to evaluate the added value of this 4D flow quantification for guiding replacement decision. KEY POINTS • Using 4D flow MRI allows a better quantification of pulmonary regurgitation in adult congenital heart disease than 2D flow when taking right ventricle remodeling after pulmonary valve replacement as a reference. • A plane positioned perpendicular to the ejected flow volume as allowed by 4D flow provides better results to estimate pulmonary regurgitation.
Collapse
Affiliation(s)
- Gilles Soulat
- Université Paris cité, PARCC (Paris-Cardiovascular Research Center), INSERM 970, 20 rue Leblanc, F-75015, Paris, France.
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France.
| | - Yousef Alattar
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Magalie Ladouceur
- Université Paris cité, PARCC (Paris-Cardiovascular Research Center), INSERM 970, 20 rue Leblanc, F-75015, Paris, France
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Damian Craiem
- Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Buenos Aires, Argentina
| | - Ariel Pascaner
- Instituto de Medicina Traslacional, Trasplante y Bioingeniería (IMeTTyB), Universidad Favaloro-CONICET, Buenos Aires, Argentina
| | - Umit Gencer
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Sophie Malekzadeh-Milani
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Laurence Iserin
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Clement Karsenty
- Université Paris cité, PARCC (Paris-Cardiovascular Research Center), INSERM 970, 20 rue Leblanc, F-75015, Paris, France
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| | - Elie Mousseaux
- Université Paris cité, PARCC (Paris-Cardiovascular Research Center), INSERM 970, 20 rue Leblanc, F-75015, Paris, France
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, F-75015, Paris, France
| |
Collapse
|
9
|
An analysis of reconstruction noise from undersampled 4D flow MRI. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2023.104800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
|
10
|
Panayiotou HR, Mills LK, Broadbent DA, Shelley D, Scheffczik J, Olaru AM, Jin N, Greenwood JP, Michael H, Plein S, Bissell MM. Comprehensive Neonatal Cardiac, Feed and Wrap, Non-contrast, Non-sedated, Free-breathing Compressed Sensing 4D Flow MRI Assessment. J Magn Reson Imaging 2023; 57:789-799. [PMID: 35792484 DOI: 10.1002/jmri.28325] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/05/2022] [Accepted: 06/06/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Cardiac MRI is an important imaging tool in congenital cardiac disease, but its use has been limited in the neonatal population as general anesthesia has been needed for breath-holding. Technological advances in four-dimensional (4D) flow MRI have now made nonsedated free-breathing acquisition protocols a viable clinical option, but the method requires prospective validation in neonates. PURPOSE To test the feasibility of compressed sensing (CS) 4D flow MRI in the neonatal population and to compare with standard previously validated two-dimensional (2D) phase-contrast (PC) flow MRI. STUDY TYPE Prospective, cohort, image quality. POPULATION A total of 14 healthy neonates (median [range] age: 2.5 [0-80] days; 8 male). FIELD STRENGTH AND SEQUENCE Noncontrast 2D cine gradient echo sequence with through-plane velocity encoding (PC) sequence and compressed sensing (CS) three-dimensional (3D), time-resolved, cine phase-contrast MRI with 3D velocity-encoding (4D flow MRI) at 3 T. ASSESSMENT Aortic 2D PC, and aortic, pulmonary trunk and superior vena cava CS 4D flow MRI were acquired using the feed and wrap technique (nonsedated) and quantified using commercially available software. Aortic flow and peak velocity were compared between methods. Internal consistency of 4D flow MRI was determined by comparing mean forward flow of the main pulmonary artery (MPA) vs. the sum of left and right pulmonary artery flows (LPA and RPA) and by comparing mean ascending aorta forward flow (AAo) vs. the sum of superior vena cava (SVC) and descending aorta flows (DAo). STATISTICAL TESTS Flow and peak-velocity comparisons were assessed using paired t-tests, with P < 0.05 considered significant, and Bland-Altman analysis. Interobserver and intraobserver agreement and internal consistency were analyzed by intraclass correlation co-efficient (ICC). RESULTS There was no statistically significant difference between ascending aortic forward flow between 2D PC and CS 4D Flow MRI (P = 0.26) with a bias of 0.11 mL (-0.59 to 0.82 mL) nor peak velocity (P = 0.11), with a bias of -5 cm/sec and (-26 to 16 cm/sec). There was excellent interobserver and intraobserver agreement for each vessel (interobserver ICC: AAo 1.00; DAo 0.94, SVC 0.90, MPA 0.99, RPA 0.98, LPA 0.96; intraobserver ICC: AAo 1.00; DAo 0.99, SVC 0.98, MPA 1.00, RPA 1.00, LPA 0.99). Internal consistency measures showed excellent agreement for both mean forward flow of main pulmonary artery vs. the sum of left and right pulmonary arteries (ICC: 0.95) and mean ascending aorta forward flow vs. the sum of superior vena cava and descending aorta flows (ICC: 1.00). CONCLUSION Sedation-free neonatal feed and wrap MRI is well tolerated and feasible. CS 4D flow MRI quantification is similar to validated 2D PC free-breathing imaging with excellent interobserver and intraobserver agreement. EVIDENCE LEVEL 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
| | - Lily K Mills
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK
| | - David A Broadbent
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK.,Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - David Shelley
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK
| | - Jutta Scheffczik
- Department of Anaesthesiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | | | - Ning Jin
- Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | - John P Greenwood
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK
| | - Helen Michael
- Department of Paediatric Cardiology, Leeds Teaching Hospitals NHS Trust, UK
| | - Sven Plein
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK
| | - Malenka M Bissell
- Biomedical Imaging Sciences Department, University of Leeds, Leeds, UK.,Department of Paediatric Cardiology, Leeds Teaching Hospitals NHS Trust, UK
| |
Collapse
|
11
|
Varga-Szemes A, Halfmann M, Schoepf UJ, Jin N, Kilburg A, Dargis DM, Düber C, Ese A, Aquino G, Xiong F, Kreitner KF, Markl M, Emrich T. Highly Accelerated Compressed-Sensing 4D Flow for Intracardiac Flow Assessment. J Magn Reson Imaging 2022. [PMID: 36264176 DOI: 10.1002/jmri.28484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 10/03/2022] [Accepted: 10/04/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Four-dimensional (4D) flow MRI allows for the quantification of complex flow patterns; however, its clinical use is limited by its inherently long acquisition time. Compressed sensing (CS) is an acceleration technique that provides substantial reduction in acquisition time. PURPOSE To compare intracardiac flow measurements between conventional and CS-based highly accelerated 4D flow acquisitions. STUDY TYPE Prospective. SUBJECTS Fifty healthy volunteers (28.0 ± 7.1 years, 24 males). FIELD STRENGTH/SEQUENCE Whole heart time-resolved 3D gradient echo with three-directional velocity encoding (4D flow) with conventional parallel imaging (factor 3) as well as CS (factor 7.7) acceleration at 3 T. ASSESSMENT 4D flow MRI data were postprocessed by applying a valve tracking algorithm. Acquisition times, flow volumes (mL/cycle) and diastolic function parameters (ratio of early to late diastolic left ventricular peak velocities [E/A] and ratio of early mitral inflow velocity to mitral annular early diastolic velocity [E/e']) were quantified by two readers. STATISTICAL TESTS Paired-samples t-test and Wilcoxon rank sum test to compare measurements. Pearson correlation coefficient (r), Bland-Altman-analysis (BA) and intraclass correlation coefficient (ICC) to evaluate agreement between techniques and readers. A P value < 0.05 was considered statistically significant. RESULTS A significant improvement in acquisition time was observed using CS vs. conventional accelerated acquisition (6.7 ± 1.3 vs. 12.0 ± 1.3 min). Net forward flow measurements for all valves showed good correlation (r > 0.81) and agreement (ICCs > 0.89) between conventional and CS acceleration, with 3.3%-8.3% underestimation by the CS technique. Evaluation of diastolic function showed 3.2%-17.6% error: E/A 2.2 [1.9-2.4] (conventional) vs. 2.3 [2.0-2.6] (CS), BA bias 0.08 [-0.81-0.96], ICC 0.82; and E/e' 4.6 [3.9-5.4] (conventional) vs. 3.8 [3.4-4.3] (CS), BA bias -0.90 [-2.31-0.50], ICC 0.89. DATA CONCLUSION Analysis of intracardiac flow patterns and evaluation of diastolic function using a highly accelerated 4D flow sequence prototype is feasible, but it shows underestimation of flow measurements by approximately 10%. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Moritz Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany.,German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Ning Jin
- Siemens Medical Solutions USA Inc., Chicago, Illinois, USA
| | - Anton Kilburg
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Danielle M Dargis
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Christoph Düber
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Amir Ese
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Gilberto Aquino
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Fei Xiong
- Siemens Medical Solutions USA Inc., Chicago, Illinois, USA
| | - Karl-Friedrich Kreitner
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina.,Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany.,German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| |
Collapse
|
12
|
Nishigake D, Yamasaki Y, Yamamura K, Funatsu R, Wada T, Oga M, Kobayashi K, Kato T, Ishigami K. High-resolution systolic T1 mapping with compressed sensing for the evaluation of the right ventricle: a phantom and volunteer study. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2022; 38:2219-2225. [PMID: 37726459 DOI: 10.1007/s10554-022-02622-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 04/12/2022] [Indexed: 11/28/2022]
Abstract
To investigate the usefulness of high-resolution systolic T1 mapping using compressed sensing for right ventricular (RV) evaluation. Phantoms and normal volunteers were scanned at 3 T by using a high-resolution (HR) modified look-locker inversion recovery (MOLLI) pulse sequence and a conventional MOLLI pulse sequence. The T1 values of the left ventricular (LV) and RV myocardium and blood pool were measured for each sequence. T1 values of HR-MOLLI and MOLLI sequences were compared in the LV myocardium, blood pool, and RV myocardium. The T1 values of HR-MOLLI and MOLLI showed good agreement in both phantoms and the LV myocardium and blood pool of volunteers. However, there was a significant difference between HR-MOLLI and MOLLI in the RV myocardium (1258 ± 52 ms vs. 1327 ± 73 ms; P = 0.0005). No significant difference was observed between the T1 value of RV and that of LV (1217 ± 32 ms) in HR-MOLLI, whereas the T1 value of RV was significantly higher than that of LV in MOLLI (P < 0.0001). The interclass correlation coefficients of intraobserver variabilities from HR-MOLLI and MOLLI were 0.919 and 0.804, respectively, and the interobserver variabilities from HR-MOLLI and MOLLI were 0.838 and 0.848, respectively. Assessment of RV myocardium by using HR systolic T1 mapping was superior to the conventional MOLLI sequence in terms of accuracy and reproducibility.
Collapse
Affiliation(s)
- Daisuke Nishigake
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Yuzo Yamasaki
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
| | - Kenichiro Yamamura
- Department of Perinatal and Pediatric Medicine, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Ryohei Funatsu
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Masahiro Oga
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koji Kobayashi
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Toyoyuki Kato
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Kousei Ishigami
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
13
|
Isoda H, Fukuyama A. Quality Control for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:278-292. [PMID: 35197395 PMCID: PMC9680545 DOI: 10.2463/mrms.rev.2021-0165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023] Open
Abstract
In recent years, 4D flow MRI has become increasingly important in clinical applications for the blood vessels in the whole body, heart, and cerebrospinal fluid. 4D flow MRI has advantages over 2D cine phase-contrast (PC) MRI in that any targeted area of interest can be analyzed post-hoc, but there are some factors to be considered, such as ensuring measurement accuracy, a long imaging time and post-processing complexity, and interobserver variability.Due to the partial volume phenomenon caused by low spatial and temporal resolutions, the accuracy of flow measurement in 4D flow MRI is reduced. For spatial resolution, it is recommended to include at least four voxels in the vessel of interest, and if possible, six voxels. In large vessels such as the aorta, large voxels can be secured and SNR can be maintained, but in small cerebral vessels, SNR is reduced, resulting in reduced accuracy. A temporal resolution of less than 40 ms is recommended. The velocity-to-noise ratio (VNR) of low-velocity blood flow is low, resulting in poor measurement accuracy. The use of dual velocity encoding (VENC) or multi-VENC is recommended to avoid velocity wrap around and to increase VNR. In order to maintain sufficient spatio-temporal resolution, a longer imaging time is required, leading to potential patient movement during examination and a corresponding decrease in measurement accuracy.For the clinical application of new technologies, including various acceleration techniques, in vitro and in vivo accuracy verification based on existing accuracy-validated 2D cine PC MRI and 4D flow MRI, as well as accuracy verification on the conservation of mass' principle, should be performed, and intraobserver repeatability, interobserver reproducibility, and test-retest reproducibility should be checked.
Collapse
Affiliation(s)
- Haruo Isoda
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
- Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Atsushi Fukuyama
- Faculty of Health Sciences, Department of Radiological Sciences, Japan Healthcare University, Sapporo, Hokkaido, Japan
| |
Collapse
|
14
|
Alattar Y, Soulat G, Gencer U, Messas E, Bollache E, Kachenoura N, Mousseaux E. Left ventricular diastolic early and late filling quantified from 4D flow magnetic resonance imaging. Diagn Interv Imaging 2022; 103:345-352. [DOI: 10.1016/j.diii.2022.02.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/17/2022] [Accepted: 02/09/2022] [Indexed: 01/02/2023]
|
15
|
Corrado PA, Seiter DP, Wieben O. Automatic measurement plane placement for 4D Flow MRI of the great vessels using deep learning. Int J Comput Assist Radiol Surg 2022; 17:199-210. [PMID: 34403045 PMCID: PMC8851604 DOI: 10.1007/s11548-021-02475-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 08/03/2021] [Indexed: 01/03/2023]
Abstract
PURPOSE Despite the great potential and flexibility of 4D flow MRI for hemodynamic analysis, a major limitation is the need for time-consuming and user-dependent post-processing. We propose a fast four-step algorithm for rapid, robust, and repeatable flow measurements in the great vessels based on automatic placement of measurement planes and vessel segmentation. METHODS Our algorithm works by (1) subsampling the 3D image into 3D patches, (2) predicting the probability of each patch containing individual vessels and location/orientation of the vessel within the patch via a convolutional neural network, (3) selecting the predicted planes with highest probabilities for each vessel, and (4) shifting the plane centers to the maximum velocity within each plane. The method was trained on 283 scans and evaluated on 40 unseen scans by comparing algorithm-derived processing times, plane locations, and flow measurements to those of two manual observers (graduate students) using t-tests, Pearson correlation, and Bland-Altman analysis. RESULTS The average processing time for the algorithm (18 s) was shorter than observer 1 (362 s; P < 0.001) and observer 2 (317 s; P < 0.001). The distance between planes placed by the algorithm and those placed by manual observers was slightly greater (O1 vs. algorithm: 9.0 mm, O2 vs. algorithm: 10.3 mm) than the distance between planes placed by the two manual observers (8.3 mm). The correlation between flow values for planes placed by the algorithm and those placed by manual observers was slightly lower (O1 vs. algorithm: R = 0.68, O2 vs. algorithm: R = 0.72) than the flow correlation between the two manual observers (R = 0.81). CONCLUSION Our method is a feasible and accurate approach for fast, reproducible, and automated flow measurement and visualization in 4D flow MRI of the great vessels, with similar variability compared to a manual annotator as the variability between two manual observers. This approach could be applied in other anatomical regions.
Collapse
Affiliation(s)
- Philip A Corrado
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.
| | - Daniel P Seiter
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Oliver Wieben
- Departments of Medical Physics and Radiology, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
16
|
Ghodrati V, Bydder M, Bedayat A, Prosper A, Yoshida T, Nguyen KL, Finn JP, Hu P. Temporally aware volumetric generative adversarial network-based MR image reconstruction with simultaneous respiratory motion compensation: Initial feasibility in 3D dynamic cine cardiac MRI. Magn Reson Med 2021; 86:2666-2683. [PMID: 34254363 PMCID: PMC10172149 DOI: 10.1002/mrm.28912] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 06/02/2021] [Accepted: 06/12/2021] [Indexed: 12/26/2022]
Abstract
PURPOSE Develop a novel three-dimensional (3D) generative adversarial network (GAN)-based technique for simultaneous image reconstruction and respiratory motion compensation of 4D MRI. Our goal was to enable high-acceleration factors 10.7X-15.8X, while maintaining robust and diagnostic image quality superior to state-of-the-art self-gating (SG) compressed sensing wavelet (CS-WV) reconstruction at lower acceleration factors 3.5X-7.9X. METHODS Our GAN was trained based on pixel-wise content loss functions, adversarial loss function, and a novel data-driven temporal aware loss function to maintain anatomical accuracy and temporal coherence. Besides image reconstruction, our network also performs respiratory motion compensation for free-breathing scans. A novel progressive growing-based strategy was adapted to make the training process possible for the proposed GAN-based structure. The proposed method was developed and thoroughly evaluated qualitatively and quantitatively based on 3D cardiac cine data from 42 patients. RESULTS Our proposed method achieved significantly better scores in general image quality and image artifacts at 10.7X-15.8X acceleration than the SG CS-WV approach at 3.5X-7.9X acceleration (4.53 ± 0.540 vs. 3.13 ± 0.681 for general image quality, 4.12 ± 0.429 vs. 2.97 ± 0.434 for image artifacts, P < .05 for both). No spurious anatomical structures were observed in our images. The proposed method enabled similar cardiac-function quantification as conventional SG CS-WV. The proposed method achieved faster central processing unit-based image reconstruction (6 s/cardiac phase) than the SG CS-WV (312 s/cardiac phase). CONCLUSION The proposed method showed promising potential for high-resolution (1 mm3 ) free-breathing 4D MR data acquisition with simultaneous respiratory motion compensation and fast reconstruction time.
Collapse
Affiliation(s)
- Vahid Ghodrati
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Biomedical Physics Inter-Departmental Graduate Program, University of California, Los Angeles, California, USA
| | - Mark Bydder
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Arash Bedayat
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Ashley Prosper
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Takegawa Yoshida
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Kim-Lien Nguyen
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Biomedical Physics Inter-Departmental Graduate Program, University of California, Los Angeles, California, USA.,Department of Medicine (Cardiology), David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - J Paul Finn
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Peng Hu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Biomedical Physics Inter-Departmental Graduate Program, University of California, Los Angeles, California, USA
| |
Collapse
|
17
|
Komoriyama H, Kamiya K, Nagai T, Oyama-Manabe N, Tsuneta S, Kobayashi Y, Kato Y, Sarashina M, Omote K, Konishi T, Sato T, Tsujinaga S, Iwano H, Shingu Y, Wakasa S, Anzai T. Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement. J Cardiovasc Magn Reson 2021; 23:81. [PMID: 34176516 PMCID: PMC8237445 DOI: 10.1186/s12968-021-00771-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 05/04/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Pre- and post-procedural hemodynamic changes which could affect adverse outcomes in aortic stenosis (AS) patients who undergo transcatheter aortic valve replacement (TAVR) have not been well investigated. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) enables accurate analysis of blood flow dynamics such as flow velocity, flow pattern, wall shear stress (WSS), and energy loss (EL). We sought to examine the changes in blood flow dynamics of patients with severe AS who underwent TAVR. METHODS We examined 32 consecutive severe AS patients who underwent TAVR between May 2018 and June 2019 (17 men, 82 ± 5 years, median left ventricular ejection fraction 61%, 6 self-expanding valve), after excluding those without CMR because of a contraindication or inadequate imaging from the analyses. We analyzed blood flow patterns, WSS and EL in the ascending aorta (AAo), and those changes before and after TAVR using 4D flow CMR. RESULTS After TAVR, semi-quantified helical flow in the AAo was significantly decreased (1.4 ± 0.6 vs. 1.9 ± 0.8, P = 0.002), whereas vortical flow and eccentricity showed no significant changes. WSS along the ascending aortic circumference was significantly decreased in the left (P = 0.038) and left anterior (P = 0.033) wall at the basal level, right posterior (P = 0.011) and left (P = 0.010) wall at the middle level, and right (P = 0.012), left posterior (P = 0.019) and left anterior (P = 0.028) wall at the upper level. EL in the AAo was significantly decreased (15.6 [10.8-25.1 vs. 25.8 [18.6-36.2]] mW, P = 0.012). Furthermore, a significant negative correlation was observed between EL and effective orifice area index after TAVR (r = - 0.38, P = 0.034). CONCLUSIONS In severe AS patients undergoing TAVR, 4D flow CMR demonstrates that TAVR improves blood flow dynamics, especially when a larger effective orifice area index is obtained.
Collapse
Affiliation(s)
- Hirokazu Komoriyama
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kiwamu Kamiya
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshiyuki Nagai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan.
| | - Noriko Oyama-Manabe
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Kita 14, Nishi 5, Kita-ku, Sapporo, Hokkaido, 060-8648, Japan
| | - Yuta Kobayashi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yoshiya Kato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Miwa Sarashina
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Kazunori Omote
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takao Konishi
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Takuma Sato
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Shingo Tsujinaga
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Hiroyuki Iwano
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yasushige Shingu
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Satoru Wakasa
- Department of Cardiovascular and Thoracic Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Toshihisa Anzai
- Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita 15, Nishi 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| |
Collapse
|
18
|
Boban M. Editorial for "Traveling Volunteers - A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance". J Magn Reson Imaging 2021; 55:223-224. [PMID: 34159678 DOI: 10.1002/jmri.27800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 06/09/2021] [Accepted: 06/10/2021] [Indexed: 11/10/2022] Open
Affiliation(s)
- Marko Boban
- Faculty for Dental Medicine and Health, University of "JJ Strossmayer", Osijek, Croatia.,Medical Faculty Rijeka, University of Rijeka, Rijeka, Croatia.,Medical Faculty Osijek, University of "JJ Strossmayer", Osijek, Croatia.,Working Group for Cardiac Magnetic Resonance of the European Society for Cardiology, Biot, France.,International Society for Magnetic Resonance Imaging, Weizmann Institute for Science, Rehovot, Israel
| |
Collapse
|
19
|
Elsayed A, Gilbert K, Scadeng M, Cowan BR, Pushparajah K, Young AA. Four-dimensional flow cardiovascular magnetic resonance in tetralogy of Fallot: a systematic review. J Cardiovasc Magn Reson 2021; 23:59. [PMID: 34011372 PMCID: PMC8136126 DOI: 10.1186/s12968-021-00745-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 03/17/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Patients with repaired Tetralogy of Fallot (rTOF) often develop cardiovascular dysfunction and require regular imaging to evaluate deterioration and time interventions such as pulmonary valve replacement. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) enables detailed assessment of flow characteristics in all chambers and great vessels. We performed a systematic review of intra-cardiac 4D flow applications in rTOF patients, to examine clinical utility and highlight optimal methods for evaluating rTOF patients. METHODS A comprehensive literature search was undertaken in March 2020 on Google Scholar and Scopus. A modified version of the Critical Appraisal Skills Programme (CASP) tool was used to assess and score the applicability of each study. Important clinical outcomes were assessed including similarities and differences. RESULTS Of the 635 articles identified, 26 studies met eligibility for systematic review. None of these were below 59% applicability on the modified CASP score. Studies could be broadly classified into four groups: (i) pilot studies, (ii) development of new acquisition methods, (iii) validation and (vi) identification of novel flow features. Quantitative comparison with other modalities included 2D phase contrast CMR (13 studies) and echocardiography (4 studies). The 4D flow study applications included stroke volume (18/26;69%), regurgitant fraction (16/26;62%), relative branch pulmonary artery flow(4/26;15%), systolic peak velocity (9/26;35%), systemic/pulmonary total flow ratio (6/26;23%), end diastolic and end systolic volume (5/26;19%), kinetic energy (5/26;19%) and vorticity (2/26;8%). CONCLUSIONS 4D flow CMR shows potential in rTOF assessment, particularly in retrospective valve tracking for flow evaluation, velocity profiling, intra-cardiac kinetic energy quantification, and vortex visualization. Protocols should be targeted to pathology. Prospective, randomized, multi-centered studies are required to validate these new characteristics and establish their clinical use.
Collapse
Affiliation(s)
- Ayah Elsayed
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Kathleen Gilbert
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Miriam Scadeng
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
| | - Brett R. Cowan
- Institute of Environmental Science and Research, Auckland, New Zealand
| | | | - Alistair A. Young
- Department of Anatomy and Medical Imaging, University of Auckland, Auckland, New Zealand
- Department of Biomedical Engineering, King’s College London, London, UK
| |
Collapse
|
20
|
Right Ventricular Volume and Function Assessment in Congenital Heart Disease Using CMR Compressed-Sensing Real-Time Cine Imaging. J Clin Med 2021; 10:jcm10091930. [PMID: 33947025 PMCID: PMC8125206 DOI: 10.3390/jcm10091930] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 04/16/2021] [Accepted: 04/20/2021] [Indexed: 11/18/2022] Open
Abstract
Background and objective: To evaluate the reliability of compressed-sensing (CS) real-time single-breath-hold cine imaging for quantification of right ventricular (RV) function and volumes in congenital heart disease (CHD) patients in comparison with the standard multi-breath-hold technique. Methods: Sixty-one consecutive CHD patients (mean age = 22.2 ± 9.0 (SD) years) were prospectively evaluated during either the initial work-up or after repair. For each patient, two series of cine images were acquired: first, the reference segmented multi-breath-hold steady-state free-precession sequence (SSFPref), including a short-axis stack, one four-chamber slice, and one long-axis slice; then, an additional real-time compressed-sensing single-breath-hold sequence (CSrt) providing the same slices. Two radiologists independently assessed the image quality and RV volumes for both techniques, which were compared using the Wilcoxon test and paired Student’s t test, Bland–Altman, and linear regression analyses. The visualization of wall-motion disorders and tricuspid-regurgitation-related signal voids were also analyzed. Results: The mean acquisition time for CSrt was 22.4 ± 6.2 (SD) s (95% CI: 20.8–23.9 s) versus 442.2 ± 89.9 (SD) s (95% CI: 419.2–465.2 s) for SSFPref (p < 0.001). The image quality of CSrt was diagnostic in all examinations and was mostly rated as good (n = 49/61; 80.3%). There was a high correlation between SSFPref and CSrt images regarding RV ejection fraction (49.8 ± 7.8 (SD)% (95% CI: 47.8–51.8%) versus 48.7 ± 8.6 (SD)% (95% CI: 46.5–50.9%), respectively; r = 0.94) and RV end-diastolic volume (192.9 ± 60.1 (SD) mL (95% CI: 177.5–208.3 mL) versus 194.9 ± 62.1 (SD) mL (95% CI: 179.0–210.8 mL), respectively; r = 0.98). In CSrt images, tricuspid-regurgitation and wall-motion disorder visualization was good (area under receiver operating characteristic curve (AUC) = 0.87) and excellent (AUC = 1), respectively. Conclusions: Compressed-sensing real-time cine imaging enables, in one breath hold, an accurate assessment of RV function and volumes in CHD patients in comparison with standard SSFPref, allowing a substantial improvement in time efficiency.
Collapse
|
21
|
Geiger J, Callaghan FM, Burkhardt BEU, Valsangiacomo Buechel ER, Kellenberger CJ. Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children. Pediatr Radiol 2021; 51:1503-1517. [PMID: 33313980 PMCID: PMC8266722 DOI: 10.1007/s00247-020-04885-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/08/2020] [Accepted: 10/12/2020] [Indexed: 12/12/2022]
Abstract
Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15-20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT. In recent years, four-dimensional (4-D) flow MRI has emerged as an additional MR technique for retrospective assessment and visualisation of blood flow within the heart and any vessel of interest within the acquired three-dimensional (3-D) volume. Its application in young children requires special adaptations for the smaller vessel size and faster heart rate compared to adolescents or adults. In this article, we provide an overview of 4-D flow MRI in various types of complex CHD in neonates and infants to demonstrate its potential indications and beneficial application for optimised individual cardiovascular assessment. We focus on its application in clinical routine cardiovascular workup and, in addition, show some examples with pathologies other than CHD to highlight that 4-D flow MRI yields new insights in disease understanding and therapy planning. We shortly review the essentials of 4-D flow data acquisition, pre- and post-processing techniques in neonates, infants and young children. Finally, we conclude with some details on accuracy, limitations and pitfalls of the technique.
Collapse
Affiliation(s)
- Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital Zürich, Steinwiesstr 75, 8032, Zürich, Switzerland. .,Children's Research Centre, University Children's Hospital Zürich, Zürich, Switzerland.
| | - Fraser M. Callaghan
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Center for MR research, University Children’s Hospital Zürich, Zürich, Switzerland
| | - Barbara E. U. Burkhardt
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Department of Pediatric Cardiology, University Hospital Zürich, Zürich, Switzerland
| | - Emanuela R. Valsangiacomo Buechel
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Department of Pediatric Cardiology, University Hospital Zürich, Zürich, Switzerland
| | - Christian J. Kellenberger
- Department of Diagnostic Imaging, University Children’s Hospital Zürich, Steinwiesstr 75, 8032 Zürich, Switzerland ,Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland
| |
Collapse
|
22
|
Rizk J. 4D flow MRI applications in congenital heart disease. Eur Radiol 2020; 31:1160-1174. [PMID: 32870392 DOI: 10.1007/s00330-020-07210-z] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 07/04/2020] [Accepted: 08/19/2020] [Indexed: 12/15/2022]
Abstract
Advances in the diagnosis and management of congenital heart disease (CHD) have resulted in a growing population of patients surviving well into adulthood and requiring lifelong follow-up. Flow quantification is a central component in the assessment of patients with CHD. 4D flow magnetic resonance imaging (MRI) has emerged as a tool that enables comprehensive study of flow. It involves the acquisition of a three-dimensional time-resolved volume with velocity encoding in all three spatial directions along the cardiac cycle. This allows flow quantification and visualization of blood flow patterns as well as the study of advanced hemodynamic parameters as kinetic energy and wall shear stress. 4D flow MRI-based study of flow has given insight into the altered hemodynamics in CHD particularly in bicuspid aortic valve disease and Fontan circulation. The aim of this review is to discuss the expanding clinical and research applications of 4D flow MRI in CHD as well its limitations.Key Points• Three-dimensional velocity encoding allows not only flow quantification but also the visualization of multidirectional flow patterns and the study of advanced hemodynamic parameters.• 4D flow MRI has added insight into the abnormal hemodynamics involved in congenital heart disease in particular in bicuspid aortic valve and Fontan circulation.• The main limitation of 4D flow MRI in congenital heart disease is the relatively long scan duration required for the complete coverage of the heart and great vessels with adequate spatiotemporal resolution.
Collapse
Affiliation(s)
- Judy Rizk
- Department of Cardiology, Faculty of Medicine, Alexandria University, El-Khartoum Square, Alexandria, 21521, Egypt.
| |
Collapse
|
23
|
Abstract
Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiac and vascular diseases. Since its introduction in the late 1980s, quantitative flow imaging with MRI has become a routine part of standard-of-care cardiothoracic and vascular MRI for the assessment of pathological changes in blood flow in patients with cardiovascular disease. More recently, time-resolved flow imaging with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (4D flow MRI) has been developed and applied to enable comprehensive 3D visualization and quantification of hemodynamics throughout the human circulatory system. This article provides an overview of the use of 4D flow applications in different cardiac and vascular regions in the human circulatory system, with a focus on using 4D flow MRI in cardiothoracic and cerebrovascular diseases.
Collapse
Affiliation(s)
- Gilles Soulat
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
| | - Patrick McCarthy
- Division of Cardiac Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois 60611, USA
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois 60208, USA
| |
Collapse
|
24
|
Jacobs K, Rigdon J, Chan F, Cheng JY, Alley MT, Vasanawala S, Maskatia SA. Direct measurement of atrioventricular valve regurgitant jets using 4D flow cardiovascular magnetic resonance is accurate and reliable for children with congenital heart disease: a retrospective cohort study. J Cardiovasc Magn Reson 2020; 22:33. [PMID: 32404159 PMCID: PMC7222506 DOI: 10.1186/s12968-020-00612-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Accepted: 03/02/2020] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND 3D-time resolved flow (4DF) cardiovascular magnetic resonance (CMR) with retrospective analysis of atrioventricular valve regurgitation (AVVR) allows for internal validation by multiple direct and indirect methods. Limited data exist on direct measurement of AVVR by 4DF CMR in pediatric congenital heart disease (CHD). We aimed to validate direct measurement of the AVVR jet as accurate and reliable compared to the volumetric method (clinical standard by 2D CMR) and as a superior method of internal validation than the annular inflow method. METHODS We identified 44 consecutive patients with diverse CHD referred for evaluation of AVVR by CMR. 1.5 T or 3 T scanners, intravenous contrast, and a combination of parallel imaging and compressed sensing were used. Four methods of measuring AVVR volume (RVol) were used: volumetric method (VOL; the clinical standard) = stroke volume by 2D balanced steady-state free precession - semilunar valve forward flow (SLFF); annular inflow method (AIM) = atrioventricular valve forward flow [AVFF] - semilunar valve net flow (SLNF); and direct measurement (JET). AVFF was measured using static and retrospective valve tracking planes. SLFF, SLNF, AVFF, and JET were measured by 4DF phase contrast. Regurgitant fraction was calculated as [RVol/(RVol+SLNF)]× 100. Statistical methods included Spearman, Wilcoxon rank sum test/Student paired t-test, Bland Altman analysis, and intra-class coefficient (ICC), where appropriate. RESULTS Regurgitant fraction by JET strongly correlated with the indirect methods (VOL and AIM) (ρ = 0.73-0.80, p < 0.001) and was similar to VOL with a median difference (interquartile range) of - 1.5% (- 8.3-7.2%; p = 0.624). VOL had weaker correlations with AIM and JET (ρ = 0.69-0.73, p < 0.001). AIM underestimated RF by 3.6-6.9% compared to VOL and JET, p < 0.03. Intra- and inter- observer reliability were excellent for all methods (ICC 0.94-0.99). The mean (±standard deviation) inter-observer difference for VOL was 2.4% (±5.1%), p < 0.05. CONCLUSIONS In a diverse cohort of pediatric CHD, measurement of AVVR using JET is accurate and reliable to VOL and is a superior method of internal validation compared to AIM. This study supports use of 4DF CMR for measurement of AVVR, obviating need for expert prospective prescription during image acquisition by 2D CMR.
Collapse
Affiliation(s)
- Kimberley Jacobs
- Department of Pediatrics, Stanford University School of Medicine, 725 Welch Rd, Room G71, MC 5906, Palo Alto, CA, 94304, USA.
| | - Joseph Rigdon
- Department of Medicine, Quantitative Sciences Unit, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Frandics Chan
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Joseph Y Cheng
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Marcus T Alley
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Shreyas Vasanawala
- Department of Radiology, Divisions of Pediatric Radiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| | - Shiraz A Maskatia
- Department of Pediatrics, Divisions of Pediatric Cardiology and Cardiovascular Imaging, Stanford University School of Medicine, 300 Pasteur Dr, Palo Alto, CA, 94305, USA
| |
Collapse
|
25
|
Urmeneta Ulloa J, Álvarez Vázquez A, Martínez de Vega V, Cabrera JÁ. Evaluation of Cardiac Shunts With
4D
Flow Cardiac Magnetic Resonance: Intra‐ and Interobserver Variability. J Magn Reson Imaging 2020; 52:1055-1063. [DOI: 10.1002/jmri.27158] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 03/18/2020] [Accepted: 03/19/2020] [Indexed: 01/03/2023] Open
Affiliation(s)
- Javier Urmeneta Ulloa
- Cardiology Department. Quirón‐Salud University Hospital European University of Madrid Madrid Spain
| | - Ana Álvarez Vázquez
- Radiology Department. Quirón‐Salud University Hospital European University of Madrid Madrid Spain
| | - Vicente Martínez de Vega
- Radiology Department. Quirón‐Salud University Hospital European University of Madrid Madrid Spain
| | - José Ángel Cabrera
- Cardiology Department. Quirón‐Salud University Hospital European University of Madrid Madrid Spain
| |
Collapse
|
26
|
Ong F, Zhu X, Cheng JY, Johnson KM, Larson PEZ, Vasanawala SS, Lustig M. Extreme MRI: Large-scale volumetric dynamic imaging from continuous non-gated acquisitions. Magn Reson Med 2020; 84:1763-1780. [PMID: 32270547 DOI: 10.1002/mrm.28235] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 02/05/2020] [Accepted: 02/06/2020] [Indexed: 12/30/2022]
Abstract
PURPOSE To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast-enhanced (DCE) imaging. THEORY AND METHODS The problem considered here requires recovering 100 gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three-dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (a) A compressed representation using multiscale low-rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (b) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory-resolved reconstruction for pulmonary imaging. RESULTS The proposed technique shows transient dynamics that are not seen in gating-based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features. CONCLUSIONS We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.
Collapse
Affiliation(s)
- Frank Ong
- Electrical Engineering, Stanford University, Stanford, CA, USA.,Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| | - Xucheng Zhu
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco, CA, USA.,Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Joseph Y Cheng
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Kevin M Johnson
- Medical Physics, University of Wisconsin, Madison, WI, USA.,Department of Radiology, University of Wisconsin, Madison, WI, USA
| | - Peder E Z Larson
- Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | | | - Michael Lustig
- Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
| |
Collapse
|
27
|
Töger J, Zahr MJ, Aristokleous N, Markenroth Bloch K, Carlsson M, Persson P. Blood flow imaging by optimal matching of computational fluid dynamics to 4D‐flow data. Magn Reson Med 2020; 84:2231-2245. [DOI: 10.1002/mrm.28269] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 02/21/2020] [Accepted: 03/09/2020] [Indexed: 01/08/2023]
Affiliation(s)
- Johannes Töger
- Department of Clinical Sciences Lund Diagnostic Radiology Lund UniversitySkåne University Hospital Lund Sweden
- Department of Clinical Sciences Lund Clinical Physiology Lund UniversitySkåne University Hospital Lund Sweden
| | - Matthew J. Zahr
- Mathematics Group Lawrence Berkeley National Laboratory Berkeley CA
- Department of Aerospace and Mechanical Engineering University of Notre Dame Notre Dame IN
| | - Nicolas Aristokleous
- Department of Clinical Sciences Lund Clinical Physiology Lund UniversitySkåne University Hospital Lund Sweden
| | | | - Marcus Carlsson
- Department of Clinical Sciences Lund Clinical Physiology Lund UniversitySkåne University Hospital Lund Sweden
| | - Per‐Olof Persson
- Mathematics Group Lawrence Berkeley National Laboratory Berkeley CA
- Department of Mathematics University of California Berkeley CA
| |
Collapse
|
28
|
Johnson EMI, Heller JA, Garcia Vicente F, Sarnari R, Gordon D, McCarthy PM, Barker AJ, Etemadi M, Markl M. Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI. Ann Biomed Eng 2020; 48:1779-1792. [PMID: 32180050 DOI: 10.1007/s10439-020-02491-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 03/09/2020] [Indexed: 01/01/2023]
Abstract
Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly and easily, with inexpensive electronics. This study investigates relationships between CMR metrics of function and SCG signal features. Same-day CMR and SCG data were collected from 28 healthy adults and 6 subjects with aortic valve disease history. Correlation testing and statistical median/decile calculations were performed with data from the healthy cohort. MR-quantified flow and function parameters in the healthy cohort correlated with particular SCG energy levels, such as peak aortic velocity with low-frequency SCG (coefficient 0.43, significance 0.02) and peak flow with high-frequency SCG (coefficient 0.40, significance 0.03). Valve disease-induced flow abnormalities in patients were visualized with MRI, and corresponding abnormalities in SCG signals were identified. This investigation found significant cross-modality correlations in cardiac function metrics and SCG signals features from healthy subjects. Additionally, through comparison to normative ranges from healthy subjects, it observed correspondences between pathological flow and abnormal SCG. This may support development of an easy clinical test used to identify potential aortic flow abnormalities.
Collapse
Affiliation(s)
- Ethan M I Johnson
- Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Tech E310, Evanston, IL, 60208, USA.
| | - J Alex Heller
- Department of Anesthesiology, Northwestern University, 676 N St Clair St, Suite 10, Chicago, IL, 60611, USA
| | - Florencia Garcia Vicente
- Department of Anesthesiology, Northwestern University, 676 N St Clair St, Suite 10, Chicago, IL, 60611, USA
| | - Roberto Sarnari
- Department of Radiology, Northwestern University, 737 N Michigan Ave, Suite 1600, Chicago, IL, 60611, USA
| | - Daniel Gordon
- Department of Radiology, Northwestern University, 737 N Michigan Ave, Suite 1600, Chicago, IL, 60611, USA
| | - Patrick M McCarthy
- Division of Cardiac Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, USA
| | - Alex J Barker
- Department of Radiology, Northwestern University, 737 N Michigan Ave, Suite 1600, Chicago, IL, 60611, USA
| | - Mozziyar Etemadi
- Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Tech E310, Evanston, IL, 60208, USA.,Department of Anesthesiology, Northwestern University, 676 N St Clair St, Suite 10, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Tech E310, Evanston, IL, 60208, USA.,Department of Radiology, Northwestern University, 737 N Michigan Ave, Suite 1600, Chicago, IL, 60611, USA
| |
Collapse
|
29
|
Bustin A, Fuin N, Botnar RM, Prieto C. From Compressed-Sensing to Artificial Intelligence-Based Cardiac MRI Reconstruction. Front Cardiovasc Med 2020; 7:17. [PMID: 32158767 PMCID: PMC7051921 DOI: 10.3389/fcvm.2020.00017] [Citation(s) in RCA: 77] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Accepted: 01/31/2020] [Indexed: 12/28/2022] Open
Abstract
Cardiac magnetic resonance (CMR) imaging is an important tool for the non-invasive assessment of cardiovascular disease. However, CMR suffers from long acquisition times due to the need of obtaining images with high temporal and spatial resolution, different contrasts, and/or whole-heart coverage. In addition, both cardiac and respiratory-induced motion of the heart during the acquisition need to be accounted for, further increasing the scan time. Several undersampling reconstruction techniques have been proposed during the last decades to speed up CMR acquisition. These techniques rely on acquiring less data than needed and estimating the non-acquired data exploiting some sort of prior information. Parallel imaging and compressed sensing undersampling reconstruction techniques have revolutionized the field, enabling 2- to 3-fold scan time accelerations to become standard in clinical practice. Recent scientific advances in CMR reconstruction hinge on the thriving field of artificial intelligence. Machine learning reconstruction approaches have been recently proposed to learn the non-linear optimization process employed in CMR reconstruction. Unlike analytical methods for which the reconstruction problem is explicitly defined into the optimization process, machine learning techniques make use of large data sets to learn the key reconstruction parameters and priors. In particular, deep learning techniques promise to use deep neural networks (DNN) to learn the reconstruction process from existing datasets in advance, providing a fast and efficient reconstruction that can be applied to all newly acquired data. However, before machine learning and DNN can realize their full potentials and enter widespread clinical routine for CMR image reconstruction, there are several technical hurdles that need to be addressed. In this article, we provide an overview of the recent developments in the area of artificial intelligence for CMR image reconstruction. The underlying assumptions of established techniques such as compressed sensing and low-rank reconstruction are briefly summarized, while a greater focus is given to recent advances in dictionary learning and deep learning based CMR reconstruction. In particular, approaches that exploit neural networks as implicit or explicit priors are discussed for 2D dynamic cardiac imaging and 3D whole-heart CMR imaging. Current limitations, challenges, and potential future directions of these techniques are also discussed.
Collapse
Affiliation(s)
- Aurélien Bustin
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Niccolo Fuin
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - René M. Botnar
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
30
|
|
31
|
Sieren MM, Berlin C, Oechtering TH, Hunold P, Drömann D, Barkhausen J, Frydrychowicz A. Comparison of 4D Flow MRI to 2D Flow MRI in the pulmonary arteries in healthy volunteers and patients with pulmonary hypertension. PLoS One 2019; 14:e0224121. [PMID: 31648286 PMCID: PMC6812822 DOI: 10.1371/journal.pone.0224121] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Accepted: 10/06/2019] [Indexed: 01/23/2023] Open
Abstract
Purpose 4D and 2D phase-contrast MRI (2D Flow MRI, 4D Flow MRI, respectively) are increasingly being used to noninvasively assess pulmonary hypertension (PH). The goals of this study were i) to evaluate whether established quantitative parameters in 2D Flow MRI associated with pulmonary hypertension can be assessed using 4D Flow MRI; ii) to compare results from 4D Flow MRI on a digital broadband 3T MR system with data from clinically established MRI-techniques as well as conservation of mass analysis and phantom correction and iii) to elaborate on the added value of secondary flow patterns in detecting PH. Methods 11 patients with PH (4f, 63 ± 16y), 15 age-matched healthy volunteers (9f, 56 ± 11y), and 20 young healthy volunteers (13f, 23 ± 2y) were scanned on a 3T MR scanner (Philips Ingenia). Subjects were examined with a 4D Flow, a 2D Flow and a bSSFP sequence. For extrinsic comparison, quantitative parameters measured with 4D Flow MRI were compared to i) a static phantom, ii) 2D Flow acquisitions and iii) stroke volume derived from a bSSFP sequence. For intrinsic comparison conservation of mass-analysis was employed. Dedicated software was used to extract various flow, velocity, and anatomical parameters. Visualization of blood flow was performed to detect secondary flow patterns. Results Overall, there was good agreement between all techniques, 4D Flow results revealed a considerable spread. Data improved after phantom correction. Both 4D and 2D Flow MRI revealed concordant results to differentiate patients from healthy individuals, especially based on values derived from anatomical parameters. The visualization of a vortex, indicating the presence of PH was achieved in 9 /11 patients and 2/35 volunteers. Discussion This study confirms that quantitative parameters used for characterizing pulmonary hypertension can be gathered using 4D Flow MRI within clinically reasonable limits of agreement. Despite its unfavorable spatial and lesser temporal resolution and a non-neglible spread of results, the identification of diseased study participants was possible.
Collapse
Affiliation(s)
- Malte Maria Sieren
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
- * E-mail:
| | - Clara Berlin
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Thekla Helene Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Peter Hunold
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Daniel Drömann
- Department of Pneumology, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Jörg Barkhausen
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Lübeck, Germany
| |
Collapse
|
32
|
Pugliese S, Vanderpool RR. Looking backwards: is it time to assess veno-atrial interactions in pulmonary arterial hypertension? Eur Respir J 2019; 54:54/4/1901598. [PMID: 31624132 DOI: 10.1183/13993003.01598-2019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 08/16/2019] [Indexed: 11/05/2022]
Affiliation(s)
- Steven Pugliese
- Pulmonary, Allergy, and Critical Care Division, University of Pennsylvania, Philadelphia, PA, USA
| | - Rebecca R Vanderpool
- Division of Translational and Regenerative Medicine, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
33
|
Suqin L, Mingli Z, Shiteng S, Honglan M, Lan Z, Qihong N, Qing L. Assessment of the Hemodynamics of Autogenous Arteriovenous Fistulas With 4D Phase Contrast-Based Flow Quantification MRI in Dialysis Patients. J Magn Reson Imaging 2019; 51:1272-1280. [PMID: 31584228 DOI: 10.1002/jmri.26936] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 08/31/2019] [Accepted: 09/05/2019] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Regular monitoring of autogenous arteriovenous fistulas (AVFs) for hemodialysis patients has importance. Hence, 4D flow MRI may be an alternative for assessing the hemodynamics of AVFs. PURPOSE To compare the hemodynamics of AVFs using Doppler ultrasound (DUS) and 4D-MRI in renal dialysis patients. STUDY TYPE Case-control study from October 2017 to April 2018. POPULATION Fifty patients (age [range] = 59.52 [39-71] years) with AVFs were included. FIELD STRENGTH/SEQUENCE Black-blood MRI and 4D flow MRI at 3.0T and AVF ultrasonography were also performed. ASSESSMENT The hemodynamics acquired from 4D flow MRI and ultrasonography by two radiologists were compared. The AVF anatomy was described through an examination of the black-blood MRI. STATISTICAL TESTS The consistency of AVF anatomy and hemodynamics and the consistency of the hemodynamics of AVFs from 4D flow MRI and ultrasound were analyzed by paired t-tests. The morphological parameters of AVFs acquired from black-blood MRI were used for a Pearson correlation analysis with the hemodynamic parameters obtained from 4D flow MRI data. RESULTS The consistency of the morphological and hemodynamic parameters measured from MRI by the two radiologists was good (all P < 0.01). The velocities and flow volumes from the 4D flow MRI and vascular ultrasound of AVFs were in moderate agreement (all P < 0.05, r = 0.292-0.569), except for the peak flow velocity at the anastomosis (P = 0.366, r = -0.078). The flow volume and WSS near the anastomotic site were closely related to the morphology of the AVFs (all P < 0.05). The hemodynamics of the complications group were significantly different from those of patients without any complications (normal patients group) (all P < 0.01). DATA CONCLUSION Compared with ultrasonography, 4D flow MRI is a promising technique to noninvasively estimate the AVF hemodynamics of renal dialysis patients. LEVEL OF EVIDENCE 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:1272-1280.
Collapse
Affiliation(s)
- Li Suqin
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Zhu Mingli
- Department of Nephrology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Suo Shiteng
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Mi Honglan
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Zhang Lan
- Department of Vascular Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Ni Qihong
- Department of Vascular Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| | - Lu Qing
- Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, China
| |
Collapse
|
34
|
Walheim J, Dillinger H, Kozerke S. Multipoint 5D flow cardiovascular magnetic resonance - accelerated cardiac- and respiratory-motion resolved mapping of mean and turbulent velocities. J Cardiovasc Magn Reson 2019; 21:42. [PMID: 31331353 PMCID: PMC6647085 DOI: 10.1186/s12968-019-0549-0] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 06/05/2019] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND Volumetric quantification of mean and fluctuating velocity components of transient and turbulent flows promises a comprehensive characterization of valvular and aortic flow characteristics. Data acquisition using standard navigator-gated 4D Flow cardiovascular magnetic resonance (CMR) is time-consuming and actual scan times depend on the breathing pattern of the subject, limiting the applicability of the method in a clinical setting. We sought to develop a 5D Flow CMR framework which combines undersampled data acquisition including multipoint velocity encoding with low-rank image reconstruction to provide cardiac- and respiratory-motion resolved assessment of velocity maps and turbulent kinetic energy in fixed scan times. METHODS Data acquisition and data-driven motion state detection was performed using an undersampled Cartesian tiny Golden angle approach. Locally low-rank (LLR) reconstruction was implemented to exploit correlations among heart phases and respiratory motion states. To ensure accurate quantification of mean and turbulent velocities, a multipoint encoding scheme with two velocity encodings per direction was incorporated. Velocity-vector fields and turbulent kinetic energy (TKE) were obtained using a Bayesian approach maximizing the posterior probability given the measured data. The scan time of 5D Flow CMR was set to 4 min. 5D Flow CMR with acceleration factors of 19 .0 ± 0.21 (mean ± std) and velocity encodings (VENC) of 0.5 m/s and 1.5 m/s per axis was compared to navigator-gated 2x SENSE accelerated 4D Flow CMR with VENC = 1.5 m/s in 9 subjects. Peak velocities and peak flow were compared and magnitude images, velocity and TKE maps were assessed. RESULTS While net scan time of 5D Flow CMR was 4 min independent of individual breathing patterns, the scan times of the standard 4D Flow CMR protocol varied depending on the actual navigator gating efficiency and were 17.8 ± 3.9 min on average. Velocity vector fields derived from 5D Flow CMR in the end-expiratory state agreed well with data obtained from the navigated 4D protocol (normalized root-mean-square error 8.9 ± 2.1%). On average, peak velocities assessed with 5D Flow CMR were higher than for the 4D protocol (3.1 ± 4.4%). CONCLUSIONS Respiratory-motion resolved multipoint 5D Flow CMR allows mapping of mean and turbulent velocities in the aorta in 4 min.
Collapse
Affiliation(s)
- Jonas Walheim
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35 8092, Zurich, Switzerland
| | - Hannes Dillinger
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35 8092, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35 8092, Zurich, Switzerland
| |
Collapse
|
35
|
Schuchardt FF, Kaller CP, Strecker C, Lambeck J, Wehrum T, Hennemuth A, Anastasopoulos C, Mader I, Harloff A. Hemodynamics of cerebral veins analyzed by 2d and 4d flow mri and ultrasound in healthy volunteers and patients with multiple sclerosis. J Magn Reson Imaging 2019; 51:205-217. [PMID: 31102341 DOI: 10.1002/jmri.26782] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 04/25/2019] [Accepted: 04/25/2019] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Hemodynamic alterations of extracranial veins are considered an etiologic factor in multiple sclerosis (MS). However, ultrasound and MRI studies could not confirm a pathophysiological link. Because of technical challenges using standard diagnostics, information about the involvement of superficial intracranial veins in proximity to the affected brain in MS is scarce. PURPOSE To comprehensively investigate the hemodynamics of intracranial veins and of the venous outflow tract in MS patients and controls. STUDY TYPE Prospective. POPULATION Twenty-eight patients with relapsing-remitting MS (EDSS1.9 ± 1.1; range 0-3) and 41 healthy controls. FIELD STRENGTH/SEQUENCE 3T/2D phase-contrast and time-resolved 4D flow MRI, extra- and transcranial sonography. ASSESSMENT Hemodynamics within the superficial and deep intracranial venous system and outflow tract including the internal, basal, and great cerebral vein, straight, superior sagittal, and transverse sinuses, internal jugular and vertebral veins. Sonography adhered to the chronic cerebrospinal venous insufficiency (CCSVI) criteria. STATISTICAL TESTS Multivariate repeated measure analysis of variance, Student's two-sample t-test, chi-square, Fisher's exact test; separate analysis of the entire cohort and 32 age- and sex-matched participants. RESULTS Multi- and univariate main effects of the factor group (MS patient vs. control) and its interactions with the factor vessel position (lower flow within dorsal superior sagittal sinus in MS, 3 ± 1 ml/s vs. 3.8 ± 1 ml/s; P < 0.05) in the uncontrolled cohort were attributable to age-related differences. Age- and sex-matched pairs showed a different velocity gradient in a single segment within the deep cerebral veins (great cerebral vein, vena cerebri magna [VCM] 7.6 ± 1.7 cm/s; straight sinus [StS] 10.5 ± 2.2 cm/s vs. volunteers: VCM 9.2 ± 2.3 cm/s; StS 10.2 ± 2.3 cm/s; P = 0.01), reaching comparable velocities instantaneously downstream. Sonography was not statistically different between groups. DATA CONCLUSION Consistent with previous studies focusing on extracranial hemodynamics, our comprehensive analysis of intracerebral venous blood flow did not reveal relevant differences between MS patients and controls. Level of Evidence 1. Technical Efficacy Stage 3. J. Magn. Reson. Imaging 2020;51:205-217.
Collapse
Affiliation(s)
- Florian F Schuchardt
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany
| | - Christoph P Kaller
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany.,Department of Neuroradiology, Medical Center, University of Freiburg, Germany
| | - Christoph Strecker
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany
| | - Johann Lambeck
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany
| | - Thomas Wehrum
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany
| | - Anja Hennemuth
- Fraunhofer Institute for Medical Image Computing MEVIS, Berlin, Germany.,Institute for Cardiovascular Computer-assisted Medicine, Charité, Universitätsmedizin Berlin, Campus Virchow-Klinikum, Germany
| | - Constantinos Anastasopoulos
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neuroradiology, Medical Center, University of Freiburg, Germany.,Department of Radiology, University of Basel, Basel, Switzerland
| | - Irina Mader
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neuroradiology, Medical Center, University of Freiburg, Germany.,Department of Radiology, Schön-Klinik, Vogtareuth, Germany
| | - Andreas Harloff
- Faculty of Medicine, University of Freiburg, Germany.,Department of Neurology and Neurophysiology, Medical Center, University of Freiburg, Germany
| |
Collapse
|
36
|
Loecher M, Magrath P, Aliotta E, Ennis DB. Time‐optimized 4D phase contrast MRI with real‐time convex optimization of gradient waveforms and fast excitation methods. Magn Reson Med 2019; 82:213-224. [DOI: 10.1002/mrm.27716] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 02/01/2019] [Accepted: 02/04/2019] [Indexed: 11/05/2022]
Affiliation(s)
- Michael Loecher
- Department of Radiological Sciences University of California Los Angeles California
| | - Patrick Magrath
- Department of Bioengineering University of California Los Angeles California
| | - Eric Aliotta
- Department of Biomedical Physics University of California Los Angeles California
| | - Daniel B. Ennis
- Department of Radiological Sciences University of California Los Angeles California
- Department of Bioengineering University of California Los Angeles California
- Department of Biomedical Physics University of California Los Angeles California
| |
Collapse
|
37
|
Ma LE, Markl M, Chow K, Huh H, Forman C, Vali A, Greiser A, Carr J, Schnell S, Barker AJ, Jin N. Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction. Magn Reson Med 2019; 81:3675-3690. [PMID: 30803006 DOI: 10.1002/mrm.27684] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 01/14/2019] [Accepted: 01/15/2019] [Indexed: 01/09/2023]
Abstract
PURPOSE To evaluate the accuracy and feasibility of a free-breathing 4D flow technique using compressed sensing (CS), where 4D flow imaging of the thoracic aorta is performed in 2 min with inline image reconstruction on the MRI scanner in less than 5 min. METHODS The 10 in vitro 4D flow MRI scans were performed with different acceleration rates on a pulsatile flow phantom (9 CS acceleration factors [R = 5.4-14.1], 1 generalized autocalibrating partially parallel acquisition [GRAPPA] R = 2). Based on in vitro results, CS-accelerated 4D flow of the thoracic aorta was acquired in 20 healthy volunteers (38.3 ± 15.2 years old) and 11 patients with aortic disease (61.3 ± 15.1 years) with R = 7.7. A conventional 4D flow scan was acquired with matched spatial coverage and temporal resolution. RESULTS CS depicted similar hemodynamics to conventional 4D flow in vitro, and in vivo, with >70% reduction in scan time (volunteers: 1:52 ± 0:25 versus 7:25 ± 2:35 min). Net flow values were within 3.5% in healthy volunteers, and voxel-by-voxel comparison demonstrated good agreement. CS significantly underestimated peak velocities (vmax ) and peak flow (Qmax ) in both volunteers and patients (volunteers: vmax , -16.2% to -9.4%, Qmax : -11.6% to -2.9%, patients: vmax , -11.2% to -4.0%; Qmax , -10.2% to -5.8%). CONCLUSION Aortic 4D flow with CS is feasible in a two minute scan with less than 5 min for inline reconstruction. While net flow agreement was excellent, CS with R = 7.7 produced underestimation of Qmax and vmax ; however, these were generally within 13% of conventional 4D flow-derived values. This approach allows 4D flow to be feasible in clinical practice for comprehensive assessment of hemodynamics.
Collapse
Affiliation(s)
- Liliana E Ma
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.,Department of Biomedical Engineering, Northwestern University, Chicago, Illinois
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.,Department of Biomedical Engineering, Northwestern University, Chicago, Illinois
| | - Kelvin Chow
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.,Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc, Chicago, Illinois
| | - Hyungkyu Huh
- Daegu-Gyeongbuk Medical Innovation Foundation, Medical Device Development Center, Daegu, South Korea
| | | | - Alireza Vali
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | | | - James Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Susanne Schnell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Alex J Barker
- Department of Radiology, Children's Hospital Colorado, University of Colorado, Anschutz Medical Campus, Denver, Colorado.,Department of Bioengineering, University of Colorado, Anschutz Medical Campus, Denver, Colorado
| | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc, Cleveland, Ohio
| |
Collapse
|
38
|
Chen C, Liu Y, Schniter P, Jin N, Craft J, Simonetti O, Ahmad R. Sparsity adaptive reconstruction for highly accelerated cardiac MRI. Magn Reson Med 2019; 81:3875-3887. [PMID: 30666694 DOI: 10.1002/mrm.27671] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 01/02/2019] [Accepted: 01/03/2019] [Indexed: 01/22/2023]
Abstract
PURPOSE To enable parameter-free, accelerated cardiovascular magnetic resonance (CMR). METHODS Regularized reconstruction methods, such as compressed sensing (CS), can significantly accelerate MRI data acquisition but require tuning of regularization weights. In this work, a technique, called Sparsity adaptive Composite Recovery (SCoRe) that exploits sparsity in multiple, disparate sparsifying transforms is presented. A data-driven adjustment of the relative contributions of different transforms yields a parameter-free CS recovery process. SCoRe is validated in a dynamic digital phantom as well as in retrospectively and prospectively undersampled cine CMR data. RESULTS The results from simulation and 6 retrospectively undersampled datasets indicate that SCoRe with auto-tuned regularization weights yields lower root-mean-square error (RMSE) and higher structural similarity index (SSIM) compared to state-of-the-art CS methods. In 45 prospectively undersampled datasets acquired from 15 volunteers, the image quality was scored by 2 expert reviewers, with SCoRe receiving a higher average score (p < 0.01) compared to other CS methods. CONCLUSIONS SCoRe enables accelerated cine CMR from highly undersampled data. In contrast to other acceleration techniques, SCoRe adapts regularization weights based on noise power and level of sparsity in each transform, yielding superior performance without admitting any free parameters.
Collapse
Affiliation(s)
- Chong Chen
- Biomedical Engineering, The Ohio State University, Columbus, Ohio
| | - Yingmin Liu
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, Ohio
| | - Philip Schniter
- Electrical and Computer Engineering, The Ohio State University, Columbus, Ohio
| | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA Inc., Columbus, Ohio
| | - Jason Craft
- Internal Medicine, The Ohio State University, Columbus, Ohio
| | - Orlando Simonetti
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, Ohio.,Internal Medicine, The Ohio State University, Columbus, Ohio.,Radiology, The Ohio State University, Columbus, Ohio
| | - Rizwan Ahmad
- Biomedical Engineering, The Ohio State University, Columbus, Ohio.,Davis Heart & Lung Research Institute, The Ohio State University, Columbus, Ohio.,Electrical and Computer Engineering, The Ohio State University, Columbus, Ohio
| |
Collapse
|
39
|
Dunås T, Holmgren M, Wåhlin A, Malm J, Eklund A. Accuracy of blood flow assessment in cerebral arteries with 4D flow MRI: Evaluation with three segmentation methods. J Magn Reson Imaging 2019; 50:511-518. [PMID: 30637846 PMCID: PMC6767555 DOI: 10.1002/jmri.26641] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 12/20/2018] [Accepted: 12/20/2018] [Indexed: 12/03/2022] Open
Abstract
Background Accelerated 4D flow MRI allows for high‐resolution velocity measurements with whole‐brain coverage. Such scans are increasingly used to calculate flow rates of individual arteries in the vascular tree, but detailed information about the accuracy and precision in relation to different postprocessing options is lacking. Purpose To evaluate and optimize three proposed segmentation methods and determine the accuracy of in vivo 4D flow MRI blood flow rate assessments in major cerebral arteries, with high‐resolution 2D PCMRI as a reference. Study Type Prospective. Subjects Thirty‐five subjects (20 women, 79 ± 5 years, range 70–91 years). Field Strength/Sequence 4D flow MRI with PC‐VIPR and 2D PCMRI acquired with a 3 T scanner. Assessment We compared blood flow rates measured with 4D flow MRI, to the reference, in nine main cerebral arteries. Lumen segmentation in the 4D flow MRI was performed with k‐means clustering using four different input datasets, and with two types of thresholding methods. The threshold was defined as a percentage of the maximum intensity value in the complex difference image. Local and global thresholding approaches were used, with evaluated thresholds from 6–26%. Statistical Tests Paired t‐test, F‐test, linear correlation (P < 0.05 was considered significant) along with intraclass correlation (ICC). Results With the thresholding methods, the lowest average flow difference was obtained for 20% local (0.02 ± 15.0 ml/min, ICC = 0.97, n = 310) or 10% global (0.08 ± 17.3 ml/min, ICC = 0.97, n = 310) thresholding with a significant lower standard deviation for local (F‐test, P = 0.01). For all clustering methods, we found a large systematic underestimation of flow compared with 2D PCMRI (16.1–22.3 ml/min). Data Conclusion A locally adapted threshold value gives a more stable result compared with a globally fixed threshold. 4D flow with the proposed segmentation method has the potential to become a useful reliable clinical tool for assessment of blood flow in the major cerebral arteries. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:511–518.
Collapse
Affiliation(s)
- Tora Dunås
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | | | - Anders Wåhlin
- Department of Radiation Sciences, Umeå University, Umeå, Sweden.,Umeå Center for Functional Brain Imaging, Umeå University, Umeå, Sweden
| | - Jan Malm
- Department of Pharmacology and Clinical Neuroscience, Umeå University, Umeå, Sweden
| | - Anders Eklund
- Department of Radiation Sciences, Umeå University, Umeå, Sweden.,Umeå Center for Functional Brain Imaging, Umeå University, Umeå, Sweden
| |
Collapse
|
40
|
Evaluation of atrial septal defects with 4D flow MRI-multilevel and inter-reader reproducibility for quantification of shunt severity. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 32:269-279. [PMID: 30171383 PMCID: PMC6424937 DOI: 10.1007/s10334-018-0702-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 08/10/2018] [Accepted: 08/16/2018] [Indexed: 01/08/2023]
Abstract
Purpose With the hypothesis that 4D flow can be used in evaluation of cardiac shunts, we seek to evaluate the multilevel and interreader reproducibility of measurements of the blood flow, shunt fraction and shunt volume in patients with atrial septum defect (ASD) in practice at multiple clinical sites. Materials and methods Four-dimensional flow MRI examinations were performed at four institutions across Europe and the US. Twenty-nine patients (mean age, 43 years; 11 male) were included in the study. Flow measurements were performed at three levels (valve, main artery and periphery) in both the pulmonary and systemic circulation by two independent readers and compared against stroke volumes from 4D flow anatomic data. Further, the shunt ratio (Qp/Qs) was calculated. Additionally, shunt volume was quantified at the atrial level by tracking the atrial septum. Results Measurements of the pulmonary blood flow at multiple levels correlate well whether measuring at the valve, main pulmonary artery or branch pulmonary arteries (r = 0.885–0.886). Measurements of the systemic blood flow show excellent correlation, whether measuring at the valve, ascending aorta or sum of flow from the superior vena cava (SVC) and descending aorta (r = 0.974–0.991). Intraclass agreement between the two observers for the flow measurements varies between 0.96 and 0.99. Compared with stroke volume, pulmonic flow is underestimated with 0.26 l/min at the main pulmonary artery level, and systemic flow is overestimated with 0.16 l/min at the ascending aorta level. Direct measurements of ASD flow are feasible in 20 of 29 (69%) patients. Conclusion Blood flow and shunt quantification measured at multiple levels and performed by different readers are reproducible and consistent with 4D flow MRI. Electronic supplementary material The online version of this article (10.1007/s10334-018-0702-z) contains supplementary material, which is available to authorized users.
Collapse
|
41
|
Siedek F, Giese D, Weiss K, Ekdawi S, Brinkmann S, Schroeder W, Bruns C, Chang DH, Persigehl T, Maintz D, Haneder S. 4D flow MRI for the analysis of celiac trunk and mesenteric artery stenoses. Magn Reson Imaging 2018; 53:52-62. [PMID: 30008436 DOI: 10.1016/j.mri.2018.06.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 05/31/2018] [Accepted: 06/28/2018] [Indexed: 01/13/2023]
Abstract
PURPOSE This study aims to assess the feasibility of 4D flow MRI measurements in complex vascular territories; namely, the celiac artery (CA) and superior mesenteric artery (SMA). MATERIALS AND METHODS In this prospective study, 22 healthy volunteers and 10 patients were scanned at 3 T. Blood flow parameters were compared between healthy volunteers and patients with stenosis of the CA and/or SMA as a function of stenosis grade characterized by prior contrast-enhanced computed tomography (CE-CT). The 4D flow MRI acquisition covered the CA, SMA and adjusting parts of the abdominal aorta (AO). Measurements of velocity- (peak velocity [PV], average velocity [AV]) and volume-related parameters (peak flow [PF], stroke volume [SV]) were conducted. Further, stenosis grade and wall shear stress in the CA, SMA and AO were evaluated. RESULTS In patients, prior evaluation by CE-CT revealed 11 low- and 5 mid-grade stenoses of the CA and/or SMA. PV and AV were significantly higher in patients than in healthy volunteers [PV: p < 0.0001; AV: p = 0.03, p < 0.001]. PF and SV did not differ significantly between healthy volunteers and patients; however, a trend towards lower PF and SV could be detected in patients with mid-grade stenoses. Comparison of 4D flow MRI with CE-CT revealed a strong positive correlation in estimated degree of stenosis (CA: r = 0.86, SMA: r = 0.98). Patients with mid-grade stenoses had a significantly higher average WSS magnitude (AWM) than healthy volunteers (p = 0.02). CONCLUSION This feasibility study suggests that 4D flow MRI is a viable technique for the evaluation of complex flow characteristics in small vessels such as the CA and SMA. 4D flow MRI approves comparable to the morphologic assessment of complex vascular territories using CE-CT but, in addition, offers the functional evaluation of flow parameters that goes beyond the morphology.
Collapse
Affiliation(s)
- Florian Siedek
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany.
| | - Daniel Giese
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Kilian Weiss
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany; Philips Healthcare Germany, Hamburg, Germany
| | - Sandra Ekdawi
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Sebastian Brinkmann
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Wolfgang Schroeder
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Christiane Bruns
- Department of General, Visceral and Tumor Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - De-Hua Chang
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Thorsten Persigehl
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - David Maintz
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Stefan Haneder
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| |
Collapse
|
42
|
Wang N, Badar F, Xia Y. Compressed sensing in quantitative determination of GAG concentration in cartilage by microscopic MRI. Magn Reson Med 2018; 79:3163-3171. [PMID: 29083096 PMCID: PMC5843514 DOI: 10.1002/mrm.26973] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 09/06/2017] [Accepted: 09/26/2017] [Indexed: 12/19/2022]
Abstract
PURPOSE To evaluate the potentials of compressed sensing (CS) in MRI quantification of glycosaminoglycan (GAG) concentration in articular cartilage at microscopic resolution. METHODS T1 -weighted 2D experiments of cartilage were fully sampled in k-space with five inversion times at 17.6 μm resolution. These fully sampled k-space data were re-processed, by undersampling at various 1D and 2D CS undersampling factors (UFs). The undersampled data were reconstructed individually into 2D images using nonlinear reconstruction, which were used to calculate 2D maps of T1 and GAG concentration. The values of T1 and GAG in cartilage were evaluated at different UFs (up to 16, which used 6.25% of the data). K-space sampling pattern and zonal variations were also investigated. RESULTS Using 2D variable density sampling pattern, the T1 images at UFs up to eight preserved major visual information and produced negligible artifacts. The GAG concentration remained accurate for different sub-tissue zones at various UFs. The variation of the mean GAG concentration through the whole tissue depth was 1.20%, compared to the fully sampled results. The maximum variation was 2.24% in the deep zone of cartilage. Using 1D variable density sampling pattern, the quantitative T1 mapping and GAG concentration at UFs up to 4 showed negligible variations. CONCLUSION This study demonstrates that CS could be beneficial in microscopic MRI (µMRI) studies of cartilage by acquiring less data, without losing significant accuracy in the quantification of GAG concentration. Magn Reson Med 79:3163-3171, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Nian Wang
- Center for In Vivo Microscopy, Department of Radiology, Duke University, Durham, NC 27710
| | - Farid Badar
- Department of Physics and Center for Biomedical Research, Oakland University, Rochester, MI 48309
| | - Yang Xia
- Department of Physics and Center for Biomedical Research, Oakland University, Rochester, MI 48309
| |
Collapse
|
43
|
Loecher M, Ennis DB. Velocity reconstruction with nonconvex optimization for low-velocity-encoding phase-contrast MRI. Magn Reson Med 2017; 80:42-52. [PMID: 29130519 DOI: 10.1002/mrm.26997] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 10/13/2017] [Accepted: 10/16/2017] [Indexed: 11/09/2022]
Abstract
PURPOSE To introduce and demonstrate a nonconvex optimization method for reconstructing velocity data from low-velocity-encoding (Venc ) phase-contrast MRI data. THEORY AND METHODS Solving for velocity values from phase-contrast MRI data was formulated as a nonconvex optimization problem. Weighting was added to account for intravoxel dephasing, and a Laplacian-based regularization was used to account for residual velocity aliasing. The reconstruction was tested with two low-Venc schemes: dual-Venc and a multidirectional high-moment encoding. The reconstruction method was tested in a digital simulation, in flow phantoms, and in healthy volunteers (N = 5). RESULTS The nonconvex-optimization reconstruction velocity error was lower than the conventional reconstruction in simulations (4.6 versus 3.0 cm/s for multidirectional high moment, 8.3 versus 3.8 cm/s for dual-Venc ) and in flow phantoms (23.9 versus 5.9 cm/s for multidirectional high moment, 15.2 versus 6.4 cm/s for dual-Venc ). Qualitative assessment of velocity fields in all experiments, including healthy volunteers, showed decreased apparent noise in the velocity fields and fewer phase wraps. No additional velocity bias in measured velocities was seen in volunteers with the proposed method. CONCLUSIONS The proposed nonconvex-optimization reconstruction method incorporates additional information to solve for velocities when using any type of low-Venc (high-moment) acquisition. The method reduces the amount of residual phase aliasing, and decreases velocity errors that result from intravoxel dephasing. These improvements allow for more robust acquisitions, and for Venc to be lowered 2 to 4 times relative to conventional acquisitions, thereby increasing the velocity-to-noise ratio. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. Magn Reson Med 80:42-52, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Michael Loecher
- Department of Radiological Sciences, University of California, Los Angeles, California, USA
| | - Daniel B Ennis
- Department of Radiological Sciences, University of California, Los Angeles, California, USA.,Department of Biomedical Physics IDP, University of California, Los Angeles, California, USA
| |
Collapse
|
44
|
Pelvic Blood Flow Predicts Fibroid Volume and Embolic Required for Uterine Fibroid Embolization: A Pilot Study With 4D Flow MR Angiography. AJR Am J Roentgenol 2017; 210:189-200. [PMID: 29090998 DOI: 10.2214/ajr.17.18127] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
OBJECTIVE We report here an initial experience using 4D flow MRI in pelvic imaging-specifically, in imaging uterine fibroids. We hypothesized that blood flow might correlate with fibroid volume and that quantifying blood flow might help to predict the amount of embolic required to achieve stasis at subsequent uterine fibroid embolization (UFE). MATERIALS AND METHODS Thirty-three patients with uterine fibroids and seven control subjects underwent pelvic MRI with 4D flow imaging. Of the patients with fibroids, 10 underwent 4D flow imaging before UFE and seven after UFE; in the remaining 16 patients with fibroids, UFE had yet to be performed. Four-dimensional flow measurements were performed using Arterys CV Flow. The flow fraction of the internal iliac artery was expressed as the ratio of internal iliac artery flow to external iliac artery flow and was compared between groups. The flow ratios between the internal iliac arteries on each side were calculated. Fibroid volume versus internal iliac flow fraction, embolic volume versus internal iliac flow fraction, and embolic volume ratio between sides versus the ratio of internal iliac artery flows between sides were compared. RESULTS The mean internal iliac flow fraction was significantly higher in the 26 patients who underwent imaging before UFE (mean ± standard error, 0.78 ± 0.06) than in the seven patients who underwent imaging after UFE (0.48 ± 0.07, p < 0.01) and in the seven control patients without fibroids (0.48 ± 0.08, p < 0.0001). The internal iliac flow fraction correlated well with fibroid volumes before UFE (r = 0.7754, p < 0.0001) and did not correlate with fibroid volumes after UFE (r = -0.3051, p = 0.51). The ratio of embolic required to achieve stasis between sides showed a modest correlation with the ratio of internal iliac flow (r = 0.6776, p = 0.03). CONCLUSION Internal iliac flow measured by 4D flow MRI correlates with fibroid volume and is predictive of the ratio of embolic required to achieve stasis on each side at subsequent UFE and may be useful for preprocedural evaluation of patients with uterine fibroids.
Collapse
|
45
|
|
46
|
Slesnick TC. Role of Computational Modelling in Planning and Executing Interventional Procedures for Congenital Heart Disease. Can J Cardiol 2017; 33:1159-1170. [PMID: 28843327 DOI: 10.1016/j.cjca.2017.05.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 05/26/2017] [Accepted: 05/27/2017] [Indexed: 10/19/2022] Open
Abstract
Increasingly, computational modelling and numerical simulations are used to help plan complex surgical and interventional cardiovascular procedures in children and young adults with congenital heart disease. From its origins more than 30 years ago, surgical planning with analysis of flow hemodynamics and energy loss/efficiency has helped design and implement many modifications to existing techniques. On the basis of patient-specific medical imaging, surgical planning allows accurate model production that can then be manipulated in a virtual surgical environment, with the proposed solutions finally tested with advanced computational fluid dynamics to evaluate the results. Applications include a broad range of congenital heart disease, including patients with single-ventricle anatomy undergoing staged palliation, those with arch obstruction, with double outlet right ventricle, or with tetralogy of Fallot. In the present work, we focus on clinical applications of this exciting field. We describe the framework for these techniques, including brief descriptions of the engineering principles applied and the interaction between "benchtop" data with medical decision-making. We highlight some early insights learned from pioneers over the past few decades, including refinements in Fontan baffle geometries and configurations. Finally, we offer a glimpse into exciting advances that are presently being explored, including use of modelling for transcatheter interventions. In this era of personalized medicine, computational modelling and surgical planning allows patient-specific tailoring of interventions to optimize clinical outcomes.
Collapse
Affiliation(s)
- Timothy C Slesnick
- Emory University School of Medicine, Children's Healthcare of Atlanta, Atlanta, Georgia.
| |
Collapse
|
47
|
Garg P, Westenberg JJM, van den Boogaard PJ, Swoboda PP, Aziz R, Foley JRJ, Fent GJ, Tyl FGJ, Coratella L, ElBaz MSM, van der Geest RJ, Higgins DM, Greenwood JP, Plein S. Comparison of fast acquisition strategies in whole-heart four-dimensional flow cardiac MR: Two-center, 1.5 Tesla, phantom and in vivo validation study. J Magn Reson Imaging 2017; 47:272-281. [PMID: 28470915 PMCID: PMC5801550 DOI: 10.1002/jmri.25746] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 04/07/2017] [Indexed: 01/02/2023] Open
Abstract
Purpose To validate three widely‐used acceleration methods in four‐dimensional (4D) flow cardiac MR; segmented 4D‐spoiled‐gradient‐echo (4D‐SPGR), 4D‐echo‐planar‐imaging (4D‐EPI), and 4D‐k‐t Broad‐use Linear Acquisition Speed‐up Technique (4D‐k‐t BLAST). Materials and Methods Acceleration methods were investigated in static/pulsatile phantoms and 25 volunteers on 1.5 Tesla MR systems. In phantoms, flow was quantified by 2D phase‐contrast (PC), the three 4D flow methods and the time‐beaker flow measurements. The later was used as the reference method. Peak velocity and flow assessment was done by means of all sequences. For peak velocity assessment 2D PC was used as the reference method. For flow assessment, consistency between mitral inflow and aortic outflow was investigated for all pulse‐sequences. Visual grading of image quality/artifacts was performed on a four‐point‐scale (0 = no artifacts; 3 = nonevaluable). Results For the pulsatile phantom experiments, the mean error for 2D PC = 1.0 ± 1.1%, 4D‐SPGR = 4.9 ± 1.3%, 4D‐EPI = 7.6 ± 1.3% and 4D‐k‐t BLAST = 4.4 ± 1.9%. In vivo, acquisition time was shortest for 4D‐EPI (4D‐EPI = 8 ± 2 min versus 4D‐SPGR = 9 ± 3 min, P < 0.05 and 4D‐k‐t BLAST = 9 ± 3 min, P = 0.29). 4D‐EPI and 4D‐k‐t BLAST had minimal artifacts, while for 4D‐SPGR, 40% of aortic valve/mitral valve (AV/MV) assessments scored 3 (nonevaluable). Peak velocity assessment using 4D‐EPI demonstrated best correlation to 2D PC (AV:r = 0.78, P < 0.001; MV:r = 0.71, P < 0.001). Coefficient of variability (CV) for net forward flow (NFF) volume was least for 4D‐EPI (7%) (2D PC:11%, 4D‐SPGR: 29%, 4D‐k‐t BLAST: 30%, respectively). Conclusion In phantom, all 4D flow techniques demonstrated mean error of less than 8%. 4D‐EPI demonstrated the least susceptibility to artifacts, good image quality, modest agreement with the current reference standard for peak intra‐cardiac velocities and the highest consistency of intra‐cardiac flow quantifications. Level of Evidence: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:272–281.
Collapse
Affiliation(s)
- Pankaj Garg
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | | | | | - Peter P Swoboda
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - Rahoz Aziz
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - James R J Foley
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - Graham J Fent
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - F G J Tyl
- Leiden University Medical Center, Leiden, The Netherlands
| | - L Coratella
- Leiden University Medical Center, Leiden, The Netherlands
| | | | | | | | - John P Greenwood
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
| |
Collapse
|
48
|
Bollache E, Barker AJ, Dolan RS, Carr JC, van Ooij P, Ahmadian R, Powell A, Collins JD, Geiger J, Markl M. k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements. Magn Reson Med 2017; 79:195-207. [PMID: 28266062 DOI: 10.1002/mrm.26661] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 02/08/2017] [Accepted: 02/08/2017] [Indexed: 01/29/2023]
Abstract
PURPOSE To assess the performance of highly accelerated free-breathing aortic four-dimensional (4D) flow MRI acquired in under 2 minutes compared to conventional respiratory gated 4D flow. METHODS Eight k-t accelerated nongated 4D flow MRI (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition kernels [PEAK GRAPPA], R = 5, TRes = 67.2 ms) using four ky -kz Cartesian sampling patterns (linear, center-out, out-center-out, random) and two spatial resolutions (SRes1 = 3.5 × 2.3 × 2.6 mm3 , SRes2 = 4.5 × 2.3 × 2.6 mm3 ) were compared in vitro (aortic coarctation flow phantom) and in 10 healthy volunteers, to conventional 4D flow (16 mm-navigator acceptance window; R = 2; TRes = 39.2 ms; SRes = 3.2 × 2.3 × 2.4 mm3 ). The best k-t accelerated approach was further assessed in 10 patients with aortic disease. RESULTS The k-t accelerated in vitro aortic peak flow (Qmax), net flow (Qnet), and peak velocity (Vmax) were lower than conventional 4D flow indices by ≤4.7%, ≤ 11%, and ≤22%, respectively. In vivo k-t accelerated acquisitions were significantly shorter but showed a trend to lower image quality compared to conventional 4D flow. Hemodynamic indices for linear and out-center-out k-space samplings were in agreement with conventional 4D flow (Qmax ≤ 13%, Qnet ≤ 13%, Vmax ≤ 17%, P > 0.05). CONCLUSION Aortic 4D flow MRI in under 2 minutes is feasible with moderate underestimation of flow indices. Differences in k-space sampling patterns suggest an opportunity to mitigate image artifacts by an optimal trade-off between scan time, acceleration, and k-space sampling. Magn Reson Med 79:195-207, 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Emilie Bollache
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex J Barker
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ryan Scott Dolan
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Pim van Ooij
- Department of Radiology, Academic Medical Center, Amsterdam, the Netherlands
| | - Rouzbeh Ahmadian
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex Powell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jeremy D Collins
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Julia Geiger
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
49
|
Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography. Int J Cardiovasc Imaging 2016; 32:301-307. [PMID: 26498478 PMCID: PMC4737795 DOI: 10.1007/s10554-015-0779-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2015] [Accepted: 09/25/2015] [Indexed: 11/21/2022]
Abstract
Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (κ = 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging.
Collapse
|
50
|
Lambert L, Grus T, Balik M, Fichtl J, Kavan J, Belohlavek J. Hemodynamic changes in patients with extracorporeal membrane oxygenation (ECMO) demonstrated by contrast-enhanced CT examinations - implications for image acquisition technique. Perfusion 2016; 32:220-225. [PMID: 27799498 DOI: 10.1177/0267659116677308] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Extracorporeal membrane oxygenation (ECMO) is an established tool for respiratory and circulatory support. In computed tomography, altered hemodynamics in ECMO patients requires special considerations and handling in contrast injection and its timing. In this article, we demonstrate changes in hemodynamics in ECMO patients captured on contrast-enhanced CT examinations and pitfalls in strategies for contrast injection in relation to the ECMO flow, cardiac function and the placement of ECMO cannulas. Contrast-enhanced CT of patients with ECMO requires prior knowledge of the ECMO cannulas, central venous lines, changes of hemodynamics induced by low cardiac output and the influence of adjustment of ECMO on blood flow in order to optimize injection of the contrast material and timing of the scan. Special considerations include temporary reduction of the ECMO flow, selection of the injection site and increasing volume or flow rate of the contrast material.
Collapse
Affiliation(s)
- Lukas Lambert
- 1 Department of Radiology, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| | - Tomas Grus
- 2 2nd Department of Surgery, Cardiovascular Surgery, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| | - Martin Balik
- 3 Department of Anesthesiology, Resuscitation and Intensive Care, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| | - Jaromir Fichtl
- 2 2nd Department of Surgery, Cardiovascular Surgery, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| | - Jan Kavan
- 1 Department of Radiology, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| | - Jan Belohlavek
- 4 2nd Department of Medicine, Cardiovascular Medicine, General University Hospital in Prague, First Faculty of Medicine, Charles University in Prague, Czech Republic
| |
Collapse
|