Uzun D, Yildirim DK, Bruce CG, Halaby RN, Jaimes A, Potersnak A, Ramasawmy R, Campbell-Washburn A, Lederman RJ, Kocaturk O. Interventional device tracking under MRI via alternating current controlled inhomogeneities. Magn Reson Med 2024; 92:346-360. [PMID: 38394163 PMCID: PMC11055668 DOI: 10.1002/mrm.30031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.
Collapse
Affiliation(s)
- Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rim N. Halaby
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Andi Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
2
|
Zhang J, Fang J, Xu Y, Si G. How AI and Robotics Will Advance Interventional Radiology: Narrative Review and Future Perspectives. Diagnostics (Basel) 2024; 14:1393. [PMID: 39001283 PMCID: PMC11241154 DOI: 10.3390/diagnostics14131393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 06/20/2024] [Accepted: 06/26/2024] [Indexed: 07/16/2024] Open
Abstract
The rapid advancement of artificial intelligence (AI) and robotics has led to significant progress in various medical fields including interventional radiology (IR). This review focuses on the research progress and applications of AI and robotics in IR, including deep learning (DL), machine learning (ML), and convolutional neural networks (CNNs) across specialties such as oncology, neurology, and cardiology, aiming to explore potential directions in future interventional treatments. To ensure the breadth and depth of this review, we implemented a systematic literature search strategy, selecting research published within the last five years. We conducted searches in databases such as PubMed and Google Scholar to find relevant literature. Special emphasis was placed on selecting large-scale studies to ensure the comprehensiveness and reliability of the results. This review summarizes the latest research directions and developments, ultimately analyzing their corresponding potential and limitations. It furnishes essential information and insights for researchers, clinicians, and policymakers, potentially propelling advancements and innovations within the domains of AI and IR. Finally, our findings indicate that although AI and robotics technologies are not yet widely applied in clinical settings, they are evolving across multiple aspects and are expected to significantly improve the processes and efficacy of interventional treatments.
Collapse
Affiliation(s)
- Jiaming Zhang
- Department of Radiology, Clinical Medical College, Southwest Medical University, Luzhou 646699, China; (J.Z.); (J.F.)
| | - Jiayi Fang
- Department of Radiology, Clinical Medical College, Southwest Medical University, Luzhou 646699, China; (J.Z.); (J.F.)
| | - Yanneng Xu
- Department of Radiology, Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou 646699, China;
| | - Guangyan Si
- Department of Radiology, Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou 646699, China;
| |
Collapse
|
3
|
Zhou W, Li X, Zabihollahy F, Lu DS, Wu HH. Deep learning-based automatic pipeline for 3D needle localization on intra-procedural 3D MRI. Int J Comput Assist Radiol Surg 2024:10.1007/s11548-024-03077-3. [PMID: 38520646 DOI: 10.1007/s11548-024-03077-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 02/09/2024] [Indexed: 03/25/2024]
Abstract
PURPOSE Accurate and rapid needle localization on 3D magnetic resonance imaging (MRI) is critical for MRI-guided percutaneous interventions. The current workflow requires manual needle localization on 3D MRI, which is time-consuming and cumbersome. Automatic methods using 2D deep learning networks for needle segmentation require manual image plane localization, while 3D networks are challenged by the need for sufficient training datasets. This work aimed to develop an automatic deep learning-based pipeline for accurate and rapid 3D needle localization on in vivo intra-procedural 3D MRI using a limited training dataset. METHODS The proposed automatic pipeline adopted Shifted Window (Swin) Transformers and employed a coarse-to-fine segmentation strategy: (1) initial 3D needle feature segmentation with 3D Swin UNEt TRansfomer (UNETR); (2) generation of a 2D reformatted image containing the needle feature; (3) fine 2D needle feature segmentation with 2D Swin Transformer and calculation of 3D needle tip position and axis orientation. Pre-training and data augmentation were performed to improve network training. The pipeline was evaluated via cross-validation with 49 in vivo intra-procedural 3D MR images from preclinical pig experiments. The needle tip and axis localization errors were compared with human intra-reader variation using the Wilcoxon signed rank test, with p < 0.05 considered significant. RESULTS The average end-to-end computational time for the pipeline was 6 s per 3D volume. The median Dice scores of the 3D Swin UNETR and 2D Swin Transformer in the pipeline were 0.80 and 0.93, respectively. The median 3D needle tip and axis localization errors were 1.48 mm (1.09 pixels) and 0.98°, respectively. Needle tip localization errors were significantly smaller than human intra-reader variation (median 1.70 mm; p < 0.01). CONCLUSION The proposed automatic pipeline achieved rapid pixel-level 3D needle localization on intra-procedural 3D MRI without requiring a large 3D training dataset and has the potential to assist MRI-guided percutaneous interventions.
Collapse
Affiliation(s)
- Wenqi Zhou
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Xinzhou Li
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Fatemeh Zabihollahy
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Joint Department of Medical Imaging, Sinai Health System and University of Toronto, Toronto, Canada
| | - David S Lu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
4
|
Schilling M, Unterberg-Buchwald C, Lotz J, Uecker M. Assessment of deep learning segmentation for real-time free-breathing cardiac magnetic resonance imaging at rest and under exercise stress. Sci Rep 2024; 14:3754. [PMID: 38355969 PMCID: PMC10866998 DOI: 10.1038/s41598-024-54164-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 02/09/2024] [Indexed: 02/16/2024] Open
Abstract
In recent years, a variety of deep learning networks for cardiac MRI (CMR) segmentation have been developed and analyzed. However, nearly all of them are focused on cine CMR under breathold. In this work, accuracy of deep learning methods is assessed for volumetric analysis (via segmentation) of the left ventricle in real-time free-breathing CMR at rest and under exercise stress. Data from healthy volunteers (n = 15) for cine and real-time free-breathing CMR at rest and under exercise stress were analyzed retrospectively. Exercise stress was performed using an ergometer in the supine position. Segmentations of two deep learning methods, a commercially available technique (comDL) and an openly available network (nnU-Net), were compared to a reference model created via the manual correction of segmentations obtained with comDL. Segmentations of left ventricular endocardium (LV), left ventricular myocardium (MYO), and right ventricle (RV) are compared for both end-systolic and end-diastolic phases and analyzed with Dice's coefficient. The volumetric analysis includes the cardiac function parameters LV end-diastolic volume (EDV), LV end-systolic volume (ESV), and LV ejection fraction (EF), evaluated with respect to both absolute and relative differences. For cine CMR, nnU-Net and comDL achieve Dice's coefficients above 0.95 for LV and 0.9 for MYO, and RV. For real-time CMR, the accuracy of nnU-Net exceeds that of comDL overall. For real-time CMR at rest, nnU-Net achieves Dice's coefficients of 0.94 for LV, 0.89 for MYO, and 0.90 for RV and the mean absolute differences between nnU-Net and the reference are 2.9 mL for EDV, 3.5 mL for ESV, and 2.6% for EF. For real-time CMR under exercise stress, nnU-Net achieves Dice's coefficients of 0.92 for LV, 0.85 for MYO, and 0.83 for RV and the mean absolute differences between nnU-Net and reference are 11.4 mL for EDV, 2.9 mL for ESV, and 3.6% for EF. Deep learning methods designed or trained for cine CMR segmentation can perform well on real-time CMR. For real-time free-breathing CMR at rest, the performance of deep learning methods is comparable to inter-observer variability in cine CMR and is usable for fully automatic segmentation. For real-time CMR under exercise stress, the performance of nnU-Net could promise a higher degree of automation in the future.
Collapse
Affiliation(s)
- Martin Schilling
- Institute for Diagnostic and Interventional Radiology, Universitätsmedizin Göttingen, Göttingen, Germany
| | - Christina Unterberg-Buchwald
- Institute for Diagnostic and Interventional Radiology, Universitätsmedizin Göttingen, Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
- Clinic of Cardiology and Pneumology, Universitätsmedizin Göttingen, Göttingen, Germany
| | - Joachim Lotz
- Institute for Diagnostic and Interventional Radiology, Universitätsmedizin Göttingen, Göttingen, Germany
| | - Martin Uecker
- Institute for Diagnostic and Interventional Radiology, Universitätsmedizin Göttingen, Göttingen, Germany.
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany.
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria.
| |
Collapse
|
5
|
Tian Y, Nayak KS. Real-time water/fat imaging at 0.55T with spiral out-in-out-in sampling. Magn Reson Med 2024; 91:649-659. [PMID: 37815020 PMCID: PMC10841523 DOI: 10.1002/mrm.29885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 08/23/2023] [Accepted: 09/21/2023] [Indexed: 10/11/2023]
Abstract
PURPOSE To develop an efficient and flexible water/fat separated real-time MRI (RT-MRI) method using spiral out-in-out-in (OIOI) sampling and balanced SSFP (bSSFP) at 0.55T. METHODS A bSSFP sequence with golden-angle spiral OIOI readout was developed, capturing three echoes to allow water/fat separation. A low-latency reconstruction that combines all echoes was available for online visualization. An offline reconstruction provided water and fat RT-MRI in two steps: (1) image reconstruction with spatiotemporally constrained reconstruction (STCR) and (2) water/fat separation with hierarchical iterative decomposition of water and fat with echo asymmetry and least-squares estimation (HIDEAL). In healthy volunteers, spiral OIOI was acquired in the wrist during a radial-to-ulnar deviation maneuver, in the heart without breath-hold and cardiac gating, and in the lower abdomen during free-breathing for visualizing small bowel motility. RESULTS We demonstrate successful water/fat separated RT-MRI for all tested applications. In the wrist, resulting images provided clear depiction of ligament gaps and their interactions during the radial-to-ulnar deviation maneuver. In the heart, water/fat RT-MRI depicted epicardial fat, provided improved delineation of epicardial coronary arteries, and provided high blood-myocardial contrast for ventricular function assessment. In the abdomen, water-only RT-MRI captured small bowel mobility clearly with improved water-fat contrast. CONCLUSIONS We have demonstrated a novel and flexible bSSFP spiral OIOI sequence at 0.55T that can provide water/fat separated RT-MRI with a variety of application-specific temporal resolution and spatial resolution requirements.
Collapse
Affiliation(s)
- Ye Tian
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
| | - Krishna S. Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
6
|
Schramm J, Cronin I, McCarter R, Mandell JG, Downing T, Kanter J, Cross R, Olivieri L. Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast. Cardiol Young 2024; 34:262-267. [PMID: 37317547 PMCID: PMC10721722 DOI: 10.1017/s1047951123001440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
BACKGROUND Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.
Collapse
Affiliation(s)
- Jennifer Schramm
- Department of Anesthesia and Critical Care Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Ileen Cronin
- Department of Pediatric Cardiology, Seattle Children's Hospital, Seattle, WA, USA
| | | | - Jason G Mandell
- Division of Pediatric Cardiology, University of Rochester Medical Center, Rochester, NY, USA
| | - Tacy Downing
- Department of Pediatric Cardiology, Children's National Medical Center, Washington, DC, USA
| | - Joshua Kanter
- Department of Pediatric Cardiology, Children's National Medical Center, Washington, DC, USA
| | - Russell Cross
- Department of Pediatric Cardiology, Children's National Medical Center, Washington, DC, USA
| | - Laura Olivieri
- Department of Pediatric Cardiology, Children's Hospital of Pittsburgh, One Children's Hospital DrivePittsburgh, PA, USA
| |
Collapse
|
7
|
Contijoch F, Rasche V, Seiberlich N, Peters DC. The future of CMR: All-in-one vs. real-time CMR (Part 2). J Cardiovasc Magn Reson 2024; 26:100998. [PMID: 38237901 PMCID: PMC11211235 DOI: 10.1016/j.jocmr.2024.100998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/10/2024] [Indexed: 02/20/2024] Open
Abstract
Cardiac Magnetic Resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR protocols. To this end, the vision of all-in-one and real-time imaging are described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 tackles the "All-in-One" approaches, and Part 2 focuses on the "Real-Time" approaches along with an overall summary of these emerging methods.
Collapse
Affiliation(s)
| | - Volker Rasche
- Ulm University Medical Center, Department of Internal Medicine II, Ulm, Germany
| | - Nicole Seiberlich
- Michigan Institute for Imaging Technology and Translation, Department of Radiology, University of Michigan, Ann Arbor, MI, USA
| | | |
Collapse
|
8
|
Vidya Shankar R, Huang L, Neji R, Kowalik G, Neofytou AP, Mooiweer R, Moon T, Mellor N, Razavi R, Pushparajah K, Roujol S. Real-time automatic image-based slice tracking of gadolinium-filled balloon wedge catheter during MR-guided cardiac catheterization: A proof-of-concept study. Magn Reson Med 2024; 91:388-397. [PMID: 37676923 PMCID: PMC10952810 DOI: 10.1002/mrm.29822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 06/28/2023] [Accepted: 07/17/2023] [Indexed: 09/09/2023]
Abstract
PURPOSE MR-guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium-filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real-time catheter tracking during MR-guided cardiac catheterization is presented. METHODS The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10-20 contiguous saturated slices combined with real-time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR-guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated. RESULTS The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real-time measurements in the phantom and patients, respectively. CONCLUSION The proposed framework enabled real-time continuous automatic tracking of a gadolinium-filled catheter balloon during MR-guided cardiac catheterization.
Collapse
Affiliation(s)
- Rohini Vidya Shankar
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Li Huang
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Radhouene Neji
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
- MR Research Collaborations, Siemens Healthcare LimitedCamberleyUK
| | - Grzegorz Kowalik
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Alexander Paul Neofytou
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Ronald Mooiweer
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
- MR Research Collaborations, Siemens Healthcare LimitedCamberleyUK
| | - Tracy Moon
- Guy's and St Thomas' NHS Foundation TrustLondonUK
| | - Nina Mellor
- Guy's and St Thomas' NHS Foundation TrustLondonUK
| | - Reza Razavi
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Kuberan Pushparajah
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Sébastien Roujol
- Biomedical Engineering Department, School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| |
Collapse
|
9
|
Marashly Q, Najjar SN, Hahn J, Rector GJ, Khawaja M, Chelu MG. Innovations in ventricular tachycardia ablation. J Interv Card Electrophysiol 2023; 66:1499-1518. [PMID: 35879516 DOI: 10.1007/s10840-022-01311-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 07/18/2022] [Indexed: 11/30/2022]
Abstract
Catheter ablation of ventricular arrhythmias (VAs) has evolved significantly over the past decade and is currently a well-established therapeutic option. Technological advances and improved understanding of VA mechanisms have led to tremendous innovations in VA ablation. The purpose of this review article is to provide an overview of current innovations in VA ablation. Mapping techniques, such as ultra-high density mapping, isochronal late activation mapping, and ripple mapping, have provided improved arrhythmogenic substrate delineation and potential procedural success while limiting duration of ablation procedure and potential hemodynamic compromise. Besides, more advanced mapping and ablation techniques such as epicardial and intramyocardial ablation approaches have allowed operators to more precisely target arrhythmogenic substrate. Moreover, advances in alternate energy sources, such as electroporation, as well as stereotactic radiation therapy have been proposed to be effective and safe. New catheters, such as the lattice and the saline-enhanced radiofrequency catheters, have been designed to provide deeper and more durable tissue ablation lesions compared to conventional catheters. Contact force optimization and baseline impedance modulation are important tools to optimize VT radiofrequency ablation and improve procedural success. Furthermore, advances in cardiac imaging, specifically cardiac MRI, have great potential in identifying arrhythmogenic substrate and evaluating ablation success. Overall, VA ablation has undergone significant advances over the past years. Innovations in VA mapping techniques, alternate energy source, new catheters, and utilization of cardiac imaging have great potential to improve overall procedural safety, hemodynamic stability, and procedural success.
Collapse
Affiliation(s)
- Qussay Marashly
- Division of Cardiology, Department of Medicine, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Salim N Najjar
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA
| | - Joshua Hahn
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA
| | - Graham J Rector
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA
| | - Muzamil Khawaja
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA
| | - Mihail G Chelu
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA.
- Baylor St. Luke's Medical Center, Houston, USA.
- Texas Heart Institute, Houston, USA.
| |
Collapse
|
10
|
Zawadzki M, Pinkiewicz M, Pinkiewicz M, Walecki J, Walczak P, Gołubczyk D, Sady M, Gajewski Z. Real-Time MRI Monitoring of Liquid Embolic Agent (Onyx) Injection in a Swine Arteriovenous Malformation Model. Brain Sci 2023; 13:915. [PMID: 37371393 DOI: 10.3390/brainsci13060915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/30/2023] [Accepted: 06/03/2023] [Indexed: 06/29/2023] Open
Abstract
The paradigm is gradually shifting, with radiosurgery and endovascular embolization being increasingly chosen over surgical resection in the selected cases of brain arteriovenous malformations. Routinely used X-ray monitoring of liquid embolic infusion has very good spatial and temporal resolution but is not without significant drawbacks regarding poor visualization of the complex AVM angioarchitecture, especially after many embolizations in the past and therefore limiting the technical ability of the embocure-total occlusion of the feeding arteries, nidus, and draining veins. The purpose of this study was to evaluate the use of real-time MRI guidance in endovascular embolization with Onyx (instead of X-ray) in a single swine rete mirabile (RM) AVM model in order to provide the scaffolding for the real-time MRI guidance method. Onyx propagation was observed in real-time dynamic GE-EPI scan with initial ipsilateral RM filling followed by main cerebral arterial branch distribution. The relatively bright signal within RM and the brain prior to Onyx injection provided a good background for the dark, low signal of the embolic agent spreading in rete mirabile and brain arteries. X-ray picture confirmed Onyx cast distribution at the end of the procedure. In this initial experience, real-time MRI seems to be a promising method that may significantly improve liquid embolic agent infusion monitoring in the future, although requiring further development before clinical use.
Collapse
Affiliation(s)
- Michał Zawadzki
- Department of Radiology, Centre of Postgraduate Medical Education, 01-813 Warsaw, Poland
- Division of Interventional Neuroradiology, Department of Radiology, The National Institute of Medicine of the Ministry of Interior and Administration, 02-507 Warsaw, Poland
| | - Miłosz Pinkiewicz
- Faculty of Medicine, Wroclaw Medical University, 50-368 Wrocław, Poland
| | - Mateusz Pinkiewicz
- Department of Diagnostic Imaging, Mazowiecki Regional Hospital in Siedlce, 08-110 Siedlce, Poland
| | - Jerzy Walecki
- Department of Radiology, Centre of Postgraduate Medical Education, 01-813 Warsaw, Poland
- Division of Interventional Neuroradiology, Department of Radiology, The National Institute of Medicine of the Ministry of Interior and Administration, 02-507 Warsaw, Poland
| | - Piotr Walczak
- Program in Image Guided Neurointerventions, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD 21201, USA
| | - Dominika Gołubczyk
- Center for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland
| | - Maria Sady
- Center for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland
| | - Zdzisław Gajewski
- Center for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland
| |
Collapse
|
11
|
Tang L, Zhao Y, Li Y, Guo R, Cai B, Wang J, Li Y, Liang ZP, Peng X, Luo J. JSENSE-Pro: Joint sensitivity estimation and image reconstruction in parallel imaging using pre-learned subspaces of coil sensitivity functions. Magn Reson Med 2023; 89:1531-1542. [PMID: 36480000 DOI: 10.1002/mrm.29548] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 11/12/2022] [Accepted: 11/15/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE To improve calibrationless parallel imaging using pre-learned subspaces of coil sensitivity functions. THEORY AND METHODS A subspace-based joint sensitivity estimation and image reconstruction method was developed for improved parallel imaging with no calibration data. Specifically, we proposed to use a probabilistic subspace model to capture prior information of the coil sensitivity functions from previous scans acquired using the same receiver system. Both the subspace basis and coefficient distributions were learned from a small set of training data. The learned subspace model was then incorporated into the regularized reconstruction formalism that includes a sparsity prior. The nonlinear optimization problem was solved using alternating minimization algorithm. Public fastMRI brain dataset was retrospectively undersampled by different schemes for performance evaluation of the proposed method. RESULTS With no calibration data, the proposed method consistently produced the most accurate coil sensitivity estimation and highest quality image reconstructions at all acceleration factors tested in comparison with state-of-the-art methods including JSENSE, DeepSENSE, P-LORAKS, and Sparse BLIP. Our results are comparable to or even better than those from SparseSENSE, which used calibration data for sensitivity estimation. The work also demonstrated that the probabilistic subspace model learned from T2 w data can be generalized to aiding the reconstruction of FLAIR data acquired from the same receiver system. CONCLUSION A subspace-based method named JSENSE-Pro has been proposed for accelerated parallel imaging without the acquisition of companion calibration data. The method is expected to further enhance the practical utility of parallel imaging, especially in applications where calibration data acquisition is not desirable or limited.
Collapse
Affiliation(s)
- Lihong Tang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yibo Zhao
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.,Beckman Institute for Advanced Sciences and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Yudu Li
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.,Beckman Institute for Advanced Sciences and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Rong Guo
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.,Beckman Institute for Advanced Sciences and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Bingyang Cai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jia Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yao Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhi-Pei Liang
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.,Beckman Institute for Advanced Sciences and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Xi Peng
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Jie Luo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
12
|
Yildirim DK, Uzun D, Bruce CG, Khan JM, Rogers T, Schenke WH, Ramasawmy R, Campbell-Washburn A, Herzka D, Lederman RJ, Kocaturk O. An interventional MRI guidewire combining profile and tip conspicuity for catheterization at 0.55T. Magn Reson Med 2023; 89:845-858. [PMID: 36198118 PMCID: PMC9712240 DOI: 10.1002/mrm.29466] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 08/04/2022] [Accepted: 09/02/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Jaffar M. Khan
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - William H. Schenke
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Daniel Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
13
|
Wang D, Rao W. Bench-to-bedside development of multifunctional flexible embolic agents. Theranostics 2023; 13:2114-2139. [PMID: 37153738 PMCID: PMC10157739 DOI: 10.7150/thno.80213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 12/22/2022] [Indexed: 05/10/2023] Open
Abstract
Transarterial chemoembolization (TACE) has been demonstrated to provide a survival benefit for patients with unresectable hepatocellular carcinoma (HCC). However, conventional TACE still faces limitations associated with complications, side effects, unsatisfactory tumor responses, repeated treatment, and narrow indications. For further improvement of TACE, additional beneficial functions such as degradability, drug-loading and releasing properties, detectability, targetability, and multiple therapeutic modalities were introduced. The purpose here is to provide a comprehensive overview of current and emerging particulate embolization technology with respect to materials. Therefore, this review systematically identified and described typical features, various functions, and practical applications of recently emerging micro/nano materials as particulate embolic agents for TACE. Besides, new insights into the liquid metals-based multifunctional and flexible embolic agents were highlighted. The current development routes and future outlooks of these micro/nano embolic materials were also presented to promote advancement in the field.
Collapse
Affiliation(s)
- Dawei Wang
- Key Lab of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- Beijing Key Lab of CryoBiomedical Engineering, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- ✉ Corresponding author: Dr. Dawei Wang. ; Pro. Wei Rao.
| | - Wei Rao
- Key Lab of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- Beijing Key Lab of CryoBiomedical Engineering, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- ✉ Corresponding author: Dr. Dawei Wang. ; Pro. Wei Rao.
| |
Collapse
|
14
|
Gruionu LG, Udriștoiu AL, Iacob AV, Constantinescu C, Stan R, Gruionu G. Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer. PLoS One 2022; 17:e0277938. [PMID: 36476838 PMCID: PMC9728835 DOI: 10.1371/journal.pone.0277938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 11/07/2022] [Indexed: 12/12/2022] Open
Abstract
Currently early diagnosis of malignant lesions at the periphery of lung parenchyma requires guidance of the biopsy needle catheter from the bronchoscope into the smaller peripheral airways via harmful X-ray radiation. Previously, we developed an image-guided system, iMTECH which uses electromagnetic tracking and although it increases the precision of biopsy collection and minimizes the use of harmful X-ray radiation during the interventional procedures, it only traces the tip of the biopsy catheter leaving the remaining catheter untraceable in real time and therefore increasing image registration error. To address this issue, we developed a shape sensing guidance system containing a fiber-Bragg grating (FBG) catheter and an artificial intelligence (AI) software, AIrShape to track and guide the entire biopsy instrument inside the lung airways, without radiation or electromagnetic navigation. We used a FBG fiber with one central and three peripheral cores positioned at 120° from each other, an array of 25 draw tower gratings with 1cm/3nm spacing, 2 mm grating length, Ormocer-T coating, and a total outer diameter of 0.2 mm. The FBG fiber was placed in the working channel of a custom made three-lumen catheter with a tip bending mechanism (FBG catheter). The AIrShape software determines the position of the FBG catheter by superimposing its position to the lung airway center lines using an AI algorithm. The feasibility of the FBG system was tested in an anatomically accurate lung airway model and validated visually and with the iMTECH platform. The results prove a viable shape-sensing hardware and software navigation solution for flexible medical instruments to reach the peripheral airways. During future studies, the feasibility of FBG catheter will be tested in pre-clinical animal models.
Collapse
Affiliation(s)
| | | | | | - Cătălin Constantinescu
- Faculty of Automation, Computers and Electronics, University of Craiova, Craiova, Romania
| | - Răzvan Stan
- Faculty of Mechanics, University of Craiova, Craiova, Romania
| | - Gabriel Gruionu
- Faculty of Mechanics, University of Craiova, Craiova, Romania
- Division of Cardiology, Department of Medicine, Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, United States of America
- * E-mail: (GG); (LGG)
| |
Collapse
|
15
|
A survey of catheter tracking concepts and methodologies. Med Image Anal 2022; 82:102584. [DOI: 10.1016/j.media.2022.102584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/01/2022] [Accepted: 08/11/2022] [Indexed: 11/23/2022]
|
16
|
Nijsink H, Overduin CG, Willems LH, Warlé MC, Fütterer JJ. Current State of MRI-Guided Endovascular Arterial Interventions: A Systematic Review of Preclinical and Clinical Studies. J Magn Reson Imaging 2022; 56:1322-1342. [PMID: 35420239 PMCID: PMC9790618 DOI: 10.1002/jmri.28205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 04/04/2022] [Accepted: 04/04/2022] [Indexed: 12/30/2022] Open
Abstract
BACKGROUND MRI guidance of arterial endovascular interventions could be beneficial as it does not require radiation exposure, allows intrinsic blood-tissue contrast, and enables three-dimensional and functional imaging, however, clinical applications are still limited. PURPOSE To review the current state of MRI-guided arterial endovascular interventions and to identify the most commonly reported challenges. STUDY TYPE Systematic review. POPULATION Pubmed, Embase, Web of Science, and The Cochrane Library were systematically searched to find relevant articles. The search strategy combined synonyms for vascular pathology, endovascular therapy, and real-time MRI guidance. FIELD STRENGTH/SEQUENCE No field strength or sequence restrictions were applied. ASSESSMENT Two reviewers independently identified and reviewed the original articles and extracted relevant data. STATISTICAL TESTS Results of the included original articles are reported. RESULTS A total of 24,809 studies were identified for screening. Eighty-eight studies were assessed for eligibility, after which data were extracted from 43 articles (6 phantom, 33 animal, and 4 human studies). Reported technical success rates for animal and human studies ranged between 42% to 100%, and the average complication rate was 5.8% (animal studies) and 8.8% (human studies). Main identified challenges were related to spatial and temporal resolution as well as safety, design, and scarcity of current MRI-compatible endovascular devices. DATA CONCLUSION MRI guidance of endovascular arterial interventions seems feasible, however, included articles included mostly small single-center case series. Several hurdles remain to be overcome before larger trials can be undertaken. Main areas of research should focus on adequate imaging protocols with integrated tracking of dedicated endovascular devices.
Collapse
Affiliation(s)
- Han Nijsink
- Department of Medical ImagingRadboudumcNijmegenNetherlands
| | | | | | | | | |
Collapse
|
17
|
Kilbride BF, Narsinh KH, Jordan CD, Mueller K, Moore T, Martin AJ, Wilson MW, Hetts SW. MRI-guided endovascular intervention: current methods and future potential. Expert Rev Med Devices 2022; 19:763-778. [PMID: 36373162 PMCID: PMC9869980 DOI: 10.1080/17434440.2022.2141110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 10/25/2022] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Image-guided endovascular interventions, performed using the insertion and navigation of catheters through the vasculature, have been increasing in number over the years, as minimally invasive procedures continue to replace invasive surgical procedures. Such endovascular interventions are almost exclusively performed under x-ray fluoroscopy, which has the best spatial and temporal resolution of all clinical imaging modalities. Magnetic resonance imaging (MRI) offers unique advantages and could be an attractive alternative to conventional x-ray guidance, but also brings with it distinctive challenges. AREAS COVERED In this review, the benefits and limitations of MRI-guided endovascular interventions are addressed, systems and devices for guiding such interventions are summarized, and clinical applications are discussed. EXPERT OPINION MRI-guided endovascular interventions are still relatively new to the interventional radiology field, since significant technical hurdles remain to justify significant costs and demonstrate safety, design, and robustness. Clinical applications of MRI-guided interventions are promising but their full potential may not be realized until proper tools designed to function in the MRI environment are available. Translational research and further preclinical studies are needed before MRI-guided interventions will be practical in a clinical interventional setting.
Collapse
Affiliation(s)
- Bridget F. Kilbride
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Kazim H. Narsinh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | | | | | - Teri Moore
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Alastair J. Martin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Mark W. Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| | - Steven W. Hetts
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
18
|
Guo F, Ng M, Kuling G, Wright G. Cardiac MRI segmentation with sparse annotations: Ensembling deep learning uncertainty and shape priors. Med Image Anal 2022; 81:102532. [PMID: 35872359 DOI: 10.1016/j.media.2022.102532] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 06/07/2022] [Accepted: 07/07/2022] [Indexed: 10/17/2022]
Abstract
The performance of deep learning for cardiac magnetic resonance imaging (MRI) segmentation is oftentimes degraded when using small datasets and sparse annotations for training or adapting a pre-trained model to previously unseen datasets. Here, we developed and evaluated an approach to addressing some of these issues to facilitate broader use of deep learning for short-axis cardiac MRI segmentation. We developed a globally optimal label fusion (GOLF) algorithm that enforced spatial smoothness to generate consensus segmentation from segmentation predictions provided by a deep learning ensemble algorithm. The GOLF consensus was entered into an uncertainty-guided coupled continuous kernel cut (ugCCKC) algorithm that employed normalized cut, image-grid continuous regularization, and "nesting" and circular shape priors of the left ventricular myocardium (LVM) and cavity (LVC). In addition, the uncertainty measurements derived from the segmentation predictions were used to constrain the similarity of GOLF and final segmentation. We optimized ugCCKC through upper bound relaxation, for which we developed an efficient coupled continuous max-flow algorithm implemented in an iterative manner. We showed that GOLF yielded average symmetric surface distance (ASSD) 0.2-0.8 mm lower than an averaging method with higher or similar Dice similarity coefficient (DSC). We also demonstrated that ugCCKC incorporating the shape priors improved DSC by 0.01-0.05 and reduced ASSD by 0.1-0.9 mm. In addition, we integrated GOLF and ugCCKC into a deep learning ensemble algorithm by refining the segmentation of an unannotated dataset and using the refined segmentation to update the trained models. With the proposed framework, we demonstrated the capability of using relatively small datasets (5-10 subjects) with sparse (5-25% slices labeled) annotations to train a deep learning algorithm, while achieving DSC of 0.871-0.893 for LVM and 0.933-0.959 for LVC on the LVQuan dataset, and these were 0.844-0.871 for LVM and 0.923-0.931 for LVC on the ACDC dataset. Furthermore, we showed that the proposed approach can be adapted to substantially alleviate the domain shift issue. Moreover, we calculated a number of commonly used LV function measurements using the derived segmentation and observed strong correlations (Pearson r=0.77-1.00, p<0.001) between algorithm and manual LV function analyses. These results suggest that the developed approaches can be used to facilitate broader application of deep learning in research and clinical cardiac MR imaging workflow.
Collapse
Affiliation(s)
- Fumin Guo
- Wuhan National Laboratory for Optoelectronics, Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China; Department of Medical Biophysics, University of Toronto, Toronto, Canada; Sunnybrook Research Institute, University of Toronto, Toronto, Canada.
| | - Matthew Ng
- Department of Medical Biophysics, University of Toronto, Toronto, Canada; Sunnybrook Research Institute, University of Toronto, Toronto, Canada
| | - Grey Kuling
- Department of Medical Biophysics, University of Toronto, Toronto, Canada; Sunnybrook Research Institute, University of Toronto, Toronto, Canada
| | - Graham Wright
- Department of Medical Biophysics, University of Toronto, Toronto, Canada; Sunnybrook Research Institute, University of Toronto, Toronto, Canada
| |
Collapse
|
19
|
Chang Y, Zhang J, Pham HA, Lyu J, Li Z. Interpretable Dimension Reduction for MRI Channel Suppression. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:1456-1459. [PMID: 36085960 DOI: 10.1109/embc48229.2022.9871474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Channel suppression can reduce the redundant information in multiple channel receiver coils and accelerate reconstruction speed to meet real-time imaging requirements. The principal component analysis has been used for channel suppression, but it is difficult to be interpreted because all channels contribute to principal components. Furthermore, the importance of interpretability in machine learning has recently attracted increasing attention in radiology. To improve the interpretability of PCA-based channel suppression, a sparse PCA method is proposed to reduce the most coils' loadings to be zero. Channel suppression is formulated as solving a nonlinear eigenvalue problem using the inverse power method instead of the direct matrix decomposition. Experimental results of in vivo data show that the sparse PCA-based channel suppression not only improves the interpretability with sparse channels, but also improves reconstruction quality compared to the standard PCA-based reconstruction with the similar reconstruction time.
Collapse
|
20
|
Greer JS, Hussein MA, Vamsee R, Arar Y, Krueger S, Weiss S, Dillenbeck J, Greil G, Veeram Reddy SR, Hussain T. Improved catheter tracking during cardiovascular magnetic resonance-guided cardiac catheterization using overlay visualization. J Cardiovasc Magn Reson 2022; 24:32. [PMID: 35650624 PMCID: PMC9161533 DOI: 10.1186/s12968-022-00863-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 04/06/2022] [Indexed: 11/07/2022] Open
Abstract
INTRODUCTION Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.
Collapse
Affiliation(s)
- Joshua S Greer
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
- Children's Medical Center Dallas, 1935 Medical District Drive, Dallas, TX, 75235, USA.
| | - Mohamed Abdelghafar Hussein
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
- Pediatric Department, Kafrelsheikh University, Kafr el-Sheikh, Egypt
| | - Ravi Vamsee
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Yousef Arar
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Sascha Krueger
- Philips Research Laboratories, Philips GmbH Innovative Technologies, Hamburg, Germany
| | - Steffen Weiss
- Philips Research Laboratories, Philips GmbH Innovative Technologies, Hamburg, Germany
| | - Jeanne Dillenbeck
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Gerald Greil
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Surendranath R Veeram Reddy
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| | - Tarique Hussain
- Department of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA
| |
Collapse
|
21
|
Bracamonte JH, Saunders SK, Wilson JS, Truong UT, Soares JS. Patient-Specific Inverse Modeling of In Vivo Cardiovascular Mechanics with Medical Image-Derived Kinematics as Input Data: Concepts, Methods, and Applications. APPLIED SCIENCES-BASEL 2022; 12:3954. [PMID: 36911244 PMCID: PMC10004130 DOI: 10.3390/app12083954] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Inverse modeling approaches in cardiovascular medicine are a collection of methodologies that can provide non-invasive patient-specific estimations of tissue properties, mechanical loads, and other mechanics-based risk factors using medical imaging as inputs. Its incorporation into clinical practice has the potential to improve diagnosis and treatment planning with low associated risks and costs. These methods have become available for medical applications mainly due to the continuing development of image-based kinematic techniques, the maturity of the associated theories describing cardiovascular function, and recent progress in computer science, modeling, and simulation engineering. Inverse method applications are multidisciplinary, requiring tailored solutions to the available clinical data, pathology of interest, and available computational resources. Herein, we review biomechanical modeling and simulation principles, methods of solving inverse problems, and techniques for image-based kinematic analysis. In the final section, the major advances in inverse modeling of human cardiovascular mechanics since its early development in the early 2000s are reviewed with emphasis on method-specific descriptions, results, and conclusions. We draw selected studies on healthy and diseased hearts, aortas, and pulmonary arteries achieved through the incorporation of tissue mechanics, hemodynamics, and fluid-structure interaction methods paired with patient-specific data acquired with medical imaging in inverse modeling approaches.
Collapse
Affiliation(s)
- Johane H. Bracamonte
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - Sarah K. Saunders
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
| | - John S. Wilson
- Department of Biomedical Engineering and Pauley Heart Center, Virginia Commonwealth University, Richmond, VA 23219, USA
| | - Uyen T. Truong
- Department of Pediatrics, School of Medicine, Children’s Hospital of Richmond at Virginia Commonwealth University, Richmond, VA 23219, USA
| | - Joao S. Soares
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA 23284, USA
- Correspondence:
| |
Collapse
|
22
|
Inam O, Qureshi M, Laraib Z, Akram H, Omer H. GPU accelerated Cartesian GRAPPA reconstruction using CUDA. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 337:107175. [PMID: 35259611 DOI: 10.1016/j.jmr.2022.107175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 02/10/2022] [Accepted: 02/21/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE GRAPPA (Generalized Auto-calibrating Partially Parallel Acquisition) is an advanced parallel MRI reconstruction method (pMRI) that enables under-sampled data acquisition with multiple receiver coils to reduce the MRI scan time and reconstructs artifact free image from the acquired under-sampled data. However, the reduction in MRI scan time comes at the expense of long reconstruction time. It is because the GRAPPA reconstruction time shows exponential growth with increasing number of receiver coils. Consequently, the conventional CPU platforms may not adhere to the requirements of fast data processing for MR image reconstruction. METHODS Graphics Processing Units (GPUs) have recently emerged as a viable commodity hardware to reduce the reconstruction time of pMRI methods. This paper presents a novel GPU based implementation of GRAPPA using custom built CUDA kernels, to meet the rising demands of fast MRI processing. The proposed framework exploits intrinsic parallelism in the calibration and synthesis phases of GRAPPA reconstruction process, aiming to achieve high speed MR image reconstruction for various GRAPPA configuration settings using different number of receiver coils, auto-calibration signals (ACS), sizes of GRAPPA kernel and acceleration factors. In-vivo experiments (using 8, 12 and 30 receiver coils) are performed to compare the performance of the proposed GPU accelerated GRAPPA with the CPU based GRAPPA extensions and GPU counterpart. RESULTS The results indicate that the proposed method achieves up to ≈47.8× , ≈17× and ≈3.8× speed up gains over multicore CPU (single thread), multicore CPU (8 thread) and Gadgetron (GPU based GRAPPA) respectively, without compromising the reconstruction accuracy. CONCLUSIONS The proposed method reduces the GRAPPA reconstruction time by employing the calibration phase (GRAPPA weights estimation) and synthesis phase (interpolation) on GPU. Our study shows that the proposed GPU based parallel framework for GRAPPA reconstruction provides a solution for high-speed image reconstruction while maintaining the quality of the reconstructed images.
Collapse
Affiliation(s)
- Omair Inam
- Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan.
| | - Mahmood Qureshi
- Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan.
| | - Zoia Laraib
- Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan
| | - Hamza Akram
- Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan
| | - Hammad Omer
- Medical Image Processing Research Group (MIPRG), Department of Electrical & Computer Engineering, COMSATS University Islamabad, Pakistan.
| |
Collapse
|
23
|
Nijsink H, Overduin CG, Brand P, De Jong SF, Borm PJA, Warlé MC, Fütterer JJ. Optimised passive marker device visibility and automatic marker detection for 3-T MRI-guided endovascular interventions: a pulsatile flow phantom study. Eur Radiol Exp 2022; 6:11. [PMID: 35199259 PMCID: PMC8866618 DOI: 10.1186/s41747-022-00262-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 01/04/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Passive paramagnetic markers on magnetic resonance imaging (MRI)-compatible endovascular devices induce susceptibility artifacts, enabling MRI-visibility and real-time MRI-guidance. Optimised visibility is crucial for automatic detection and device tracking but depends on MRI technical parameters and marker characteristics. We assessed marker visibility and automatic detection robustness for varying MRI parameters and marker characteristics in a pulsatile flow phantom. METHODS Guidewires with varying iron(II,III) oxide nanoparticle (IONP) concentration markers were imaged using gradient-echo (GRE) and balanced steady-state free precession (bSSFP) sequences at 3 T. Furthermore, echo time (TE), slice thickness (ST) and phase encoding direction (PED) were varied. Artifact width was measured and contrast-to-noise ratios were calculated. Marker visibility and image quality were scored by two MRI interventional radiologists. Additionally, a deep learning model for automatic marker detection was trained and the effects of the parameters on detection performance were evaluated. Two-tailed Wilcoxon signed-rank tests were used (significance level, p < 0.05). RESULTS Medan artifact width (IQR) was larger in bSSFP compared to GRE images (12.7 mm (11.0-15.2) versus 8.4 mm (6.5-11.0)) (p < 0.001) and showed a positive relation with TE and IONP concentration. Switching PED and doubling ST had limited effect on artifact width. Image quality assessment scores were higher for GRE compared to bSSFP images. The deep learning model automatically detected the markers. However, the model performance was reduced after adjusting PED, TE, and IONP concentration. CONCLUSION Marker visibility was sufficient and a large range of artifact sizes was generated by adjusting TE and IONP concentration. Deep learning-based marker detection was feasible but performance decreased for altered MR parameters. These factors should be considered to optimise device visibility and ensure reliable automatic marker detectability in MRI-guided endovascular interventions.
Collapse
Affiliation(s)
- Han Nijsink
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands.
| | - Christiaan G Overduin
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| | - Patrick Brand
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| | - Sytse F De Jong
- Department of Cardiothoracic Surgery, Radboudumc, Nijmegen, The Netherlands
| | | | - Michiel C Warlé
- Department of Vascular and Transplant Surgery, Radboudumc, Nijmegen, The Netherlands
| | - Jurgen J Fütterer
- Department of Medical Imaging, Radboudumc, Geert Grooteplein Zuid 10, 6525, Nijmegen, GA, The Netherlands
| |
Collapse
|
24
|
Amin EK, Campbell-Washburn A, Ratnayaka K. MRI-Guided Cardiac Catheterization in Congenital Heart Disease: How to Get Started. Curr Cardiol Rep 2022; 24:419-429. [PMID: 35107702 PMCID: PMC8979923 DOI: 10.1007/s11886-022-01659-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/15/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE OF REVIEW Cardiac magnetic resonance imaging provides radiation-free, 3-dimensional soft tissue visualization with adjunct hemodynamic data, making it a promising candidate for image-guided transcatheter interventions. This review focuses on the benefits and background of real-time magnetic resonance imaging (MRI)-guided cardiac catheterization, guidance on starting a clinical program, and recent research developments. RECENT FINDINGS Interventional cardiac magnetic resonance (iCMR) has an established track record with the first entirely MRI-guided cardiac catheterization for congenital heart disease reported nearly 20 years ago. Since then, many centers have embarked upon clinical iCMR programs primarily performing diagnostic MRI-guided cardiac catheterization. There have also been limited reports of successful real-time MRI-guided transcatheter interventions. Growing experience in performing cardiac catheterization in the magnetic resonance environment has facilitated practical workflows appropriate for efficiency-focused cardiac catheterization laboratories. Most exciting developments in imaging technology, MRI-compatible equipment and MRI-guided novel transcatheter interventions have been limited to preclinical research. Many of these research developments are ready for clinical translation. With increasing iCMR clinical experience and translation of preclinical research innovations, the time to make the leap to radiation-free procedures is now.
Collapse
Affiliation(s)
- Elena K Amin
- Division of Pediatric Cardiology, UCSF Benioff Children's Hospitals, University of California, San Francisco, San Francisco, CA, USA.
| | - Adrienne Campbell-Washburn
- Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Kanishka Ratnayaka
- Division of Pediatric Cardiology, Rady Children's Hospital, University of California, San Diego, 3020 Children's Way, San Diego, CA, USA
| |
Collapse
|
25
|
Nayak KS, Lim Y, Campbell-Washburn AE, Steeden J. Real-Time Magnetic Resonance Imaging. J Magn Reson Imaging 2022; 55:81-99. [PMID: 33295674 PMCID: PMC8435094 DOI: 10.1002/jmri.27411] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Revised: 10/06/2020] [Accepted: 10/09/2020] [Indexed: 01/03/2023] Open
Abstract
Real-time magnetic resonance imaging (RT-MRI) allows for imaging dynamic processes as they occur, without relying on any repetition or synchronization. This is made possible by modern MRI technology such as fast-switching gradients and parallel imaging. It is compatible with many (but not all) MRI sequences, including spoiled gradient echo, balanced steady-state free precession, and single-shot rapid acquisition with relaxation enhancement. RT-MRI has earned an important role in both diagnostic imaging and image guidance of invasive procedures. Its unique diagnostic value is prominent in areas of the body that undergo substantial and often irregular motion, such as the heart, gastrointestinal system, upper airway vocal tract, and joints. Its value in interventional procedure guidance is prominent for procedures that require multiple forms of soft-tissue contrast, as well as flow information. In this review, we discuss the history of RT-MRI, fundamental tradeoffs, enabling technology, established applications, and current trends. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Krishna S. Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA,Address reprint requests to: K.S.N., 3740 McClintock Ave, EEB 400C, Los Angeles, CA 90089-2564, USA.
| | - Yongwan Lim
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Adrienne E. Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Jennifer Steeden
- Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, University College London, London, UK
| |
Collapse
|
26
|
Franson D, Dupuis A, Gulani V, Griswold M, Seiberlich N. A System for Real-Time, Online Mixed-Reality Visualization of Cardiac Magnetic Resonance Images. J Imaging 2021; 7:jimaging7120274. [PMID: 34940741 PMCID: PMC8709155 DOI: 10.3390/jimaging7120274] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 12/07/2021] [Accepted: 12/09/2021] [Indexed: 11/16/2022] Open
Abstract
Image-guided cardiovascular interventions are rapidly evolving procedures that necessitate imaging systems capable of rapid data acquisition and low-latency image reconstruction and visualization. Compared to alternative modalities, Magnetic Resonance Imaging (MRI) is attractive for guidance in complex interventional settings thanks to excellent soft tissue contrast and large fields-of-view without exposure to ionizing radiation. However, most clinically deployed MRI sequences and visualization pipelines exhibit poor latency characteristics, and spatial integration of complex anatomy and device orientation can be challenging on conventional 2D displays. This work demonstrates a proof-of-concept system linking real-time cardiac MR image acquisition, online low-latency reconstruction, and a stereoscopic display to support further development in real-time MR-guided intervention. Data are acquired using an undersampled, radial trajectory and reconstructed via parallelized through-time radial generalized autocalibrating partially parallel acquisition (GRAPPA) implemented on graphics processing units. Images are rendered for display in a stereoscopic mixed-reality head-mounted display. The system is successfully tested by imaging standard cardiac views in healthy volunteers. Datasets comprised of one slice (46 ms), two slices (92 ms), and three slices (138 ms) are collected, with the acquisition time of each listed in parentheses. Images are displayed with latencies of 42 ms/frame or less for all three conditions. Volumetric data are acquired at one volume per heartbeat with acquisition times of 467 ms and 588 ms when 8 and 12 partitions are acquired, respectively. Volumes are displayed with a latency of 286 ms or less. The faster-than-acquisition latencies for both planar and volumetric display enable real-time 3D visualization of the heart.
Collapse
Affiliation(s)
- Dominique Franson
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Correspondence: (D.F.); (A.D.)
| | - Andrew Dupuis
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Correspondence: (D.F.); (A.D.)
| | - Vikas Gulani
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA; (V.G.); (N.S.)
| | - Mark Griswold
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA;
- Department of Radiology, Case Western Reserve University, Cleveland, OH 44106, USA
| | - Nicole Seiberlich
- Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA; (V.G.); (N.S.)
| |
Collapse
|
27
|
Jaubert O, Montalt‐Tordera J, Knight D, Coghlan GJ, Arridge S, Steeden JA, Muthurangu V. Real-time deep artifact suppression using recurrent U-Nets for low-latency cardiac MRI. Magn Reson Med 2021; 86:1904-1916. [PMID: 34032308 PMCID: PMC8613539 DOI: 10.1002/mrm.28834] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 03/22/2021] [Accepted: 04/17/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE Real-time low latency MRI is performed to guide various cardiac interventions. Real-time acquisitions often require iterative image reconstruction strategies, which lead to long reconstruction times. In this study, we aim to reconstruct highly undersampled radial real-time data with low latency using deep learning. METHODS A 2D U-Net with convolutional long short-term memory layers is proposed to exploit spatial and preceding temporal information to reconstruct highly accelerated tiny golden radial data with low latency. The network was trained using a dataset of breath-hold CINE data (including 770 time series from 7 different orientations). Synthetic paired data were created by retrospectively undersampling the magnitude images, and the network was trained to recover the target images. In the spirit of interventional imaging, the network was trained and tested for varying acceleration rates and orientations. Data were prospectively acquired and reconstructed in real time in 1 healthy subject interactively and in 3 patients who underwent catheterization. Images were visually compared to sliding window and compressed sensing reconstructions and a conventional Cartesian real-time sequence. RESULTS The proposed network generalized well to different acceleration rates and unseen orientations for all considered metrics in simulated data (less than 4% reduction in structural similarity index compared to similar acceleration and orientation-specific networks). The proposed reconstruction was demonstrated interactively, successfully depicting catheters in vivo with low latency (39 ms, including 19 ms for deep artifact suppression) and an image quality comparing favorably to other reconstructions. CONCLUSION Deep artifact suppression was successfully demonstrated in the time-critical application of non-Cartesian real-time interventional cardiac MR.
Collapse
Affiliation(s)
- Olivier Jaubert
- Department of Computer ScienceUniversity College LondonLondonUnited Kingdom
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
| | - Javier Montalt‐Tordera
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
| | - Dan Knight
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
- Department of CardiologyRoyal Free London NHS Foundation TrustLondonUnited Kingdom
| | - Gerry J. Coghlan
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
- Department of CardiologyRoyal Free London NHS Foundation TrustLondonUnited Kingdom
| | - Simon Arridge
- Department of Computer ScienceUniversity College LondonLondonUnited Kingdom
| | - Jennifer A. Steeden
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
| | - Vivek Muthurangu
- UCL Centre for Translational Cardiovascular ImagingUniversity College LondonLondonUnited Kingdom
| |
Collapse
|
28
|
Godinez F, Tomi-Tricot R, Delcey M, Williams SE, Mooiweer R, Quesson B, Razavi R, Hajnal JV, Malik SJ. Interventional cardiac MRI using an add-on parallel transmit MR system: In vivo experience in sheep. Magn Reson Med 2021; 86:3360-3372. [PMID: 34286866 DOI: 10.1002/mrm.28931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/15/2021] [Accepted: 06/28/2021] [Indexed: 12/19/2022]
Abstract
PURPOSE We present in vivo testing of a parallel transmit system intended for interventional MR-guided cardiac procedures. METHODS The parallel transmit system was connected in-line with a conventional 1.5 Tesla MRI system to transmit and receive on an 8-coil array. The system used a current sensor for real-time feedback to achieve real-time current control by determining coupling and null modes. Experiments were conducted on 4 Charmoise sheep weighing 33.9-45.0 kg with nitinol guidewires placed under X-ray fluoroscopy in the atrium or ventricle of the heart via the femoral vein. Heating tests were done in vivo and post-mortem with a high RF power imaging sequence using the coupling mode. Anatomical imaging was done using a combination of null modes optimized to produce a useable B1 field in the heart. RESULTS Anatomical imaging produced cine images of the heart comparable in quality to imaging with the quad mode (all channels with the same amplitude and phase). Maximum observed temperature increases occurred when insulation was stripped from the wire tip. These were 4.1℃ and 0.4℃ for the coupling mode and null modes, respectively for the in vivo case; increasing to 6.0℃ and 1.3℃, respectively for the ex vivo case, because cooling from blood flow is removed. Heating < 0.1℃ was observed when insulation was not stripped from guidewire tips. In all tests, the parallel transmit system managed to reduce the temperature at the guidewire tip. CONCLUSION We have demonstrated the first in vivo usage of an auxiliary parallel transmit system employing active feedback-based current control for interventional MRI with a conventional MRI scanner.
Collapse
Affiliation(s)
- Felipe Godinez
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Raphael Tomi-Tricot
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Marylène Delcey
- Centre de Recherche Cardio, Thoracique de Bordeaux/IHU Liryc, INSERM U1045-University of Bordeaux, Pessac, France.,Siemens Healthcare, Saint-Denis, France
| | - Steven E Williams
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Ronald Mooiweer
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Bruno Quesson
- Centre de Recherche Cardio, Thoracique de Bordeaux/IHU Liryc, INSERM U1045-University of Bordeaux, Pessac, France
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Joseph V Hajnal
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Shaihan J Malik
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.,Centre for the Developing Brain, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
29
|
Unger M, Berger J, Melzer A. Robot-Assisted Image-Guided Interventions. Front Robot AI 2021; 8:664622. [PMID: 34322519 PMCID: PMC8312560 DOI: 10.3389/frobt.2021.664622] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 07/01/2021] [Indexed: 12/23/2022] Open
Abstract
Image guidance is a common methodology of minimally invasive procedures. Depending on the type of intervention, various imaging modalities are available. Common imaging modalities are computed tomography, magnetic resonance tomography, and ultrasound. Robotic systems have been developed to enable and improve the procedures using these imaging techniques. Spatial and technological constraints limit the development of versatile robotic systems. This paper offers a brief overview of the developments of robotic systems for image-guided interventions since 2015 and includes samples of our current research in this field.
Collapse
Affiliation(s)
- Michael Unger
- Innovation Center Computer Assisted Surgery, Leipzig, Germany
| | - Johann Berger
- Innovation Center Computer Assisted Surgery, Leipzig, Germany
| | - Andreas Melzer
- Innovation Center Computer Assisted Surgery, Leipzig, Germany.,Institute for Medical Science and Technology, IMSaT, University Dundee, Dundee, United Kingdom
| |
Collapse
|
30
|
Wang D, Wu Q, Guo R, Lu C, Niu M, Rao W. Magnetic liquid metal loaded nano-in-micro spheres as fully flexible theranostic agents for SMART embolization. NANOSCALE 2021; 13:8817-8836. [PMID: 33960346 DOI: 10.1039/d1nr01268a] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Transcatheter arterial chemoembolization (TACE) has become one of the preferred choices for advanced liver cancer patients. Current clinically used microsphere embolic agents, such as PVA, gelatin, and alginate microspheres, have limited therapeutic efficacy and lack the function of real-time imaging. In this work, we fabricated magnetic liquid metal nanoparticle (Fe@EGaIn NP) loaded calcium alginate (CA) microspheres (denoted as Fe@EGaIn/CA microspheres), which integrate CT/MR dual-modality imaging and photothermal/photodynamic functions of the Fe@EGaIn NP core, as well as embolization and drug-loading functions of CA microspheres. Namely, such nano-in-micro spheres can be used as fully flexible theranostic agents to achieve smart-chemoembolization. It has been confirmed by in vitro and in vivo experiments that Fe@EGaIn/CA microspheres have advantageous morphology, favorable biocompatibility, splendid versatility, and advanced embolic efficacy. Benefiting from these properties, excellent therapeutic efficiency was achieved with a tumor growth-inhibiting value of 100% in tumor-bearing rabbits. As a novel microsphere embolic agent with promising therapeutic efficacy and diagnostic capability, Fe@EGaIn/CA microspheres have shown potential applications in clinical transcatheter arterial chemoembolization. And the preparation strategy presented here provides a generalized paradigm for achieving multifunctional and fully flexible theranostics.
Collapse
Affiliation(s)
- Dawei Wang
- Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China. and School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qirun Wu
- Department of Interventional Medical, Zhuhai People's Hospital (Zhuhai hospital affiliated with Jinan University), Zhuhai 519000, China
| | - Rui Guo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Chennan Lu
- Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China. and School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Meng Niu
- Department of Radiology, First Hospital of China Medical University, Shenyang 110001, China
| | - Wei Rao
- Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China. and School of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
31
|
Delcey M, Bour P, Ozenne V, Ben Hassen W, Quesson B. A fast MR-thermometry method for quantitative assessment of temperature increase near an implanted wire. PLoS One 2021; 16:e0250636. [PMID: 33983935 PMCID: PMC8118538 DOI: 10.1371/journal.pone.0250636] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 04/09/2021] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To propose a MR-thermometry method and associated data processing technique to predict the maximal RF-induced temperature increase near an implanted wire for any other MRI sequence. METHODS A dynamic single shot echo planar imaging sequence was implemented that interleaves acquisition of several slices every second and an energy deposition module with adjustable parameters. Temperature images were processed in real time and compared to invasive fiber-optic measurements to assess accuracy of the method. The standard deviation of temperature was measured in gel and in vivo in the human brain of a volunteer. Temperature increases were measured for different RF exposure levels in a phantom containing an inserted wire and then a MR-conditional pacemaker lead. These calibration data set were fitted to a semi-empirical model allowing estimation of temperature increase of other acquisition sequences. RESULTS The precision of the measurement obtained after filtering with a 1.6x1.6 mm2 in plane resolution was 0.2°C in gel, as well as in the human brain. A high correspondence was observed with invasive temperature measurements during RF-induced heating (0.5°C RMSE for a 11.5°C temperature increase). Temperature rises of 32.4°C and 6.5°C were reached at the tip of a wire and of a pacemaker lead, respectively. After successful fitting of temperature curves of the calibration data set, temperature rise predicted by the model was in good agreement (around 5% difference) with measured temperature by a fiber optic probe, for three other MRI sequences. CONCLUSION This method proposes a rapid and reliable quantification of the temperature rise near an implanted wire. Calibration data set and resulting fitting coefficients can be used to estimate temperature increase for any MRI sequence as function of its power and duration.
Collapse
Affiliation(s)
- Marylène Delcey
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France
- Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Univ. Bordeaux, Bordeaux, France
- INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
- Siemens Healthcare, Saint-Denis, France
- * E-mail:
| | - Pierre Bour
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France
- Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Univ. Bordeaux, Bordeaux, France
- INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
| | - Valéry Ozenne
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France
- Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Univ. Bordeaux, Bordeaux, France
- INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
| | | | - Bruno Quesson
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France
- Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Univ. Bordeaux, Bordeaux, France
- INSERM, Centre de recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux, France
| |
Collapse
|
32
|
Yildirim DK, Bruce C, Uzun D, Rogers T, O'Brien K, Ramasawmy R, Campbell-Washburn A, Herzka DA, Lederman RJ, Kocaturk O. A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T. Magn Reson Med 2021; 86:1786-1801. [PMID: 33860962 DOI: 10.1002/mrm.28804] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 03/05/2021] [Accepted: 03/23/2021] [Indexed: 01/14/2023]
Abstract
PURPOSE This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.
Collapse
Affiliation(s)
- Dursun Korel Yildirim
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Christopher Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Dogangun Uzun
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Toby Rogers
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Kendall O'Brien
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Daniel A Herzka
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert J Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Kandilli Campus, Istanbul, Turkey.,Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
33
|
Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids-Efficiency Assessment with the Use of Dynamic Contrast-Enhanced Magnetic Resonance Imaging and the Potential Role of the Administration of Uterotonic Drugs. Diagnostics (Basel) 2021; 11:diagnostics11040715. [PMID: 33923667 PMCID: PMC8072686 DOI: 10.3390/diagnostics11040715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/11/2021] [Accepted: 04/13/2021] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE The assessment of the usefulness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) when qualifying patients with uterine fibroids (UFs) for magnetic resonance-guided high-intensity ultrasound (MR-HIFU). MATERIAL AND METHODS This retrospective, single center study included 283 women who underwent DCE-MRI and were treated with MR-HIFU. The patients were divided according to non-perfused volume (NPV) as well as by the type of curve for patients with a washout curve in the DCE-MRI study and patients without a washout curve. The studied women were assessed in three groups according to the type of uterotonics administered. Group A (57 patients) received one dose of misoprostol/diclofenac transvaginally and group B (71 patients) received oxytocin intravenously prior to the MR-HIFU procedure. The remaining 155 women (group C) were treated with the traditional non-drug enhanced MR-HIFU procedure. RESULTS The average NPV value was higher in no washout group, and depended on the uterotonics used. CONCLUSIONS We demonstrated a correlation between dynamic contrast enhancement curve types and the therapeutic efficacy of MR-HIFU. Our results suggest that DCE-MRI has the potential to assess treatment outcomes among patients with UFs, and patients with UFs that present with a washout curve may benefit from the use of uterotonic drugs. More studies are required to draw final conclusions.
Collapse
|
34
|
MR and ultrasound cardiac image dynamic visualization and synchronization over Internet for distributed heart function diagnosis. Comput Med Imaging Graph 2020; 88:101850. [PMID: 33418302 DOI: 10.1016/j.compmedimag.2020.101850] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 12/15/2020] [Accepted: 12/18/2020] [Indexed: 11/23/2022]
Abstract
Dual-modality 4D cardiac data visualization can convey a significant amount of complementary image information from various sources into a single and meaningful display. Even though there are existing publications on combining multiple medical images into a unique representation, there has been no work on rendering a series of cardiac image sequences, acquired from multiple sources, using web browsers and synchronizing the result over the Internet in real time. The ability to display multi-modality beating heart images using Web-based technology is hampered by the lack of efficient algorithms for fusing and visualizing constantly updated multi-source images and streaming the rendering results using internet protocols. To address this practical issue, in this paper we introduce a new Internet-based algorithm and a software platform running on a Node.js server, where a series of registered cardiac images from both magnetic resonance (MR) and ultrasound are employed to display dynamic fused cardiac structures in web browsers. Taking advantage of the bidirectional WebSocket protocol and WebGL-based graphics acceleration, internal cardiac structures are dynamically displayed, and the results of rendering and data exploration are synchronized among all the connected client computers. The presented research and software have the potential to provide clinicians with comprehensive information and intuitive feedback relating to cardiac behavior and anatomy and could impact areas such as distributed diagnosis of cardiac function and collaborative treatment planning for various heart diseases.
Collapse
|
35
|
Li X, Young AS, Raman SS, Lu DS, Lee YH, Tsao TC, Wu HH. Automatic needle tracking using Mask R-CNN for MRI-guided percutaneous interventions. Int J Comput Assist Radiol Surg 2020; 15:1673-1684. [PMID: 32676870 DOI: 10.1007/s11548-020-02226-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 07/03/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE Accurate needle tracking provides essential information for MRI-guided percutaneous interventions. Passive needle tracking using MR images is challenged by variations of the needle-induced signal void feature in different situations. This work aimed to develop an automatic needle tracking algorithm for MRI-guided interventions based on the Mask Region Proposal-Based Convolutional Neural Network (R-CNN). METHODS Mask R-CNN was adapted and trained to segment the needle feature using 250 intra-procedural images from 85 MRI-guided prostate biopsy cases and 180 real-time images from MRI-guided needle insertion in ex vivo tissue. The segmentation masks were passed into the needle feature localization algorithm to extract the needle feature tip location and axis orientation. The proposed algorithm was tested using 208 intra-procedural images from 40 MRI-guided prostate biopsy cases, and 3 real-time MRI datasets in ex vivo tissue. The algorithm results were compared with human-annotated references. RESULTS In prostate datasets, the proposed algorithm achieved needle feature tip localization error with median Euclidean distance (dxy) of 0.71 mm and median difference in axis orientation angle (dθ) of 1.28°, respectively. In 3 real-time MRI datasets, the proposed algorithm achieved consistent dynamic needle feature tracking performance with processing time of 75 ms/image: (a) median dxy = 0.90 mm, median dθ = 1.53°; (b) median dxy = 1.31 mm, median dθ = 1.9°; (c) median dxy = 1.09 mm, median dθ = 0.91°. CONCLUSIONS The proposed algorithm using Mask R-CNN can accurately track the needle feature tip and axis on MR images from in vivo intra-procedural prostate biopsy cases and ex vivo real-time MRI experiments with a range of different conditions. The algorithm achieved pixel-level tracking accuracy in real time and has potential to assist MRI-guided percutaneous interventions.
Collapse
Affiliation(s)
- Xinzhou Li
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Adam S Young
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - Steven S Raman
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - David S Lu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA
| | - Yu-Hsiu Lee
- Department of Mechanical and Aerospace Engineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Tsu-Chin Tsao
- Department of Mechanical and Aerospace Engineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, 300 UCLA Medical Plaza, Suite B119, Los Angeles, CA, 90095, USA.
- Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
36
|
Salavitabar A, Figueroa CA, Lu JC, Owens ST, Axelrod DM, Zampi JD. Emerging 3D technologies and applications within congenital heart disease: teach, predict, plan and guide. Future Cardiol 2020; 16:695-709. [PMID: 32628520 DOI: 10.2217/fca-2020-0004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
3D visualization technologies have evolved to become a mainstay in the management of congenital heart disease (CHD) with a growing presence within multiple facets. Printed and virtual 3D models allow for a more comprehensive approach to educating trainees and care team members. Computational fluid dynamics can take 3D modeling to the next level, by predicting post-procedural outcomes and helping to determine surgical approach. 3D printing and extended reality are developing resources for pre-procedural planning and intra-procedural guidance with the potential to revolutionize decision-making and procedural success. Challenges still remain within existing technologies and their applications to the CHD field. Addressing these gaps, both by those within and outside of CHD, will transform education and patient care within our field.
Collapse
Affiliation(s)
- Arash Salavitabar
- C.S. Mott Children's Hospital, University of Michigan Congenital Heart Center, Ann Arbor, MI 48109, USA
| | - C Alberto Figueroa
- Departments of Biomedical Engineering & Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Jimmy C Lu
- C.S. Mott Children's Hospital, University of Michigan Congenital Heart Center, Ann Arbor, MI 48109, USA
| | - Sonal T Owens
- C.S. Mott Children's Hospital, University of Michigan Congenital Heart Center, Ann Arbor, MI 48109, USA
| | - David M Axelrod
- Division of Pediatric Cardiology, Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA 94304, USA
| | - Jeffrey D Zampi
- C.S. Mott Children's Hospital, University of Michigan Congenital Heart Center, Ann Arbor, MI 48109, USA
| |
Collapse
|
37
|
Hamideh RA, Akbari B, Fathi P, Misra SK, Sutrisno A, Lam F, Pan D. Biodegradable MRI Visible Drug Eluting Stent Reinforced by Metal Organic Frameworks. Adv Healthc Mater 2020; 9:e2000136. [PMID: 32548977 DOI: 10.1002/adhm.202000136] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 04/13/2020] [Indexed: 12/18/2022]
Abstract
Metal-organic frameworks (MOFs) have applications in numerous fields. However, the development of MOF-based "theranostic" macroscale devices is not achieved. Here, heparin-coated biocompatible MOF/poly(ε-caprolactone) (PCL) "theranostic" stents are developed, where NH2 -Materials of Institute Lavoisier (MIL)-101(Fe) encapsulates and releases rapamycin (an immunosuppressive drug). These stents also act as a remarkable source of contrast in ex vivo magnetic resonance imaging (MRI) compared to the invisible polymeric stent. The in vitro release patterns of heparin and rapamycin respectively can ensure a type of programmed model to prevent blood coagulation immediately after stent placement in the artery and stenosis over a longer term. Due to the presence of hydrolysable functionalities in MOFs, the stents are shown to be highly biodegradable in degradation tests under various conditions. Furthermore, there is no compromise of mechanical strength or flexibility with MOF compositing. The system described here promises many biomedical applications in macroscale theranostic devices. The use of MOF@PCL can render a medical device MRI-visible while simultaneously acting as a carrier for therapeutic agents.
Collapse
Affiliation(s)
- Rezvani Alanagh Hamideh
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, P.O. Box 14395-1561, Tehran, Iran
- Department of Bioengineering, Beckman Institute of Advanced Science and Technology, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Carle Foundation Hospital, 611 West Park Street, Urbana, IL, 61801, USA
| | - Babak Akbari
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, P.O. Box 14395-1561, Tehran, Iran
| | - Parinaz Fathi
- Department of Bioengineering, Beckman Institute of Advanced Science and Technology, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Carle Foundation Hospital, 611 West Park Street, Urbana, IL, 61801, USA
| | - Santosh K Misra
- Department of Bioengineering, Beckman Institute of Advanced Science and Technology, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Carle Foundation Hospital, 611 West Park Street, Urbana, IL, 61801, USA
| | - Andre Sutrisno
- NMR/EPR Laboratory, School of Chemical Sciences, University of Illinois at Urbana-Champaign, IL, USA
| | - Fan Lam
- Department of Bioengineering, Beckman Institute of Advanced Science and Technology, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Carle Foundation Hospital, 611 West Park Street, Urbana, IL, 61801, USA
| | - Dipanjan Pan
- Department of Bioengineering, Beckman Institute of Advanced Science and Technology, Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Carle Foundation Hospital, 611 West Park Street, Urbana, IL, 61801, USA
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland Baltimore, Health Sciences Facility III, 670 W Baltimore St., Baltimore, MD, 21201, USA
- Department of Pediatrics, University of Maryland Baltimore, Health Sciences Facility III, 670 W Baltimore St., Baltimore, MD, 21201, USA
- Department of Chemical, Biochemical and Environmental Engineering, University of Maryland Baltimore County, Interdisciplinary Health Sciences Facility, 1000 Hilltop Circle, Baltimore, MD, 21250, USA
| |
Collapse
|
38
|
Respiratory Motion Prediction Using Fusion-Based Multi-Rate Kalman Filtering and Real-Time Golden-Angle Radial MRI. IEEE Trans Biomed Eng 2020; 67:1727-1738. [DOI: 10.1109/tbme.2019.2944803] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
39
|
Real-time 3T MRI-guided cardiovascular catheterization in a porcine model using a glass-fiber epoxy-based guidewire. PLoS One 2020; 15:e0229711. [PMID: 32102092 PMCID: PMC7043930 DOI: 10.1371/journal.pone.0229711] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Accepted: 02/13/2020] [Indexed: 11/19/2022] Open
Abstract
PURPOSE Real-time magnetic resonance imaging (MRI) is a promising alternative to X-ray fluoroscopy for guiding cardiovascular catheterization procedures. Major challenges, however, include the lack of guidewires that are compatible with the MRI environment, not susceptible to radiofrequency-induced heating, and reliably visualized. Preclinical evaluation of new guidewire designs has been conducted at 1.5T. Here we further evaluate the safety (device heating), device visualization, and procedural feasibility of 3T MRI-guided cardiovascular catheterization using a novel MRI-visible glass-fiber epoxy-based guidewire in phantoms and porcine models. METHODS To evaluate device safety, guidewire tip heating (GTH) was measured in phantom experiments with different combinations of catheters and guidewires. In vivo cardiovascular catheterization procedures were performed in both healthy (N = 5) and infarcted (N = 5) porcine models under real-time 3T MRI guidance using a glass-fiber epoxy-based guidewire. The times for each procedural step were recorded separately. Guidewire visualization was assessed by measuring the dimensions of the guidewire-induced signal void and contrast-to-noise ratio (CNR) between the guidewire tip signal void and the blood signal in real-time gradient-echo MRI (specific absorption rate [SAR] = 0.04 W/kg). RESULTS In the phantom experiments, GTH did not exceed 0.35°C when using the real-time gradient-echo sequence (SAR = 0.04 W/kg), demonstrating the safety of the glass-fiber epoxy-based guidewire at 3T. The catheter was successfully placed in the left ventricle (LV) under real-time MRI for all five healthy subjects and three out of five infarcted subjects. Signal void dimensions and CNR values showed consistent visualization of the glass-fiber epoxy-based guidewire in real-time MRI. The average time (minutes:seconds) for the catheterization procedure in all subjects was 4:32, although the procedure time varied depending on the subject's specific anatomy (standard deviation = 4:41). CONCLUSIONS Real-time 3T MRI-guided cardiovascular catheterization using a new MRI-visible glass-fiber epoxy-based guidewire is feasible in terms of visualization and guidewire navigation, and safe in terms of radiofrequency-induced guidewire tip heating.
Collapse
|
40
|
FPGA-based hardware accelerator for SENSE (a parallel MR image reconstruction method). Comput Biol Med 2020; 117:103598. [PMID: 32072979 DOI: 10.1016/j.compbiomed.2019.103598] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 12/23/2019] [Accepted: 12/30/2019] [Indexed: 11/20/2022]
Abstract
SENSE (Sensitivity Encoding) is a parallel MRI (pMRI) technique that allows accelerated data acquisition using multiple receiver coils and reconstructs the artifact-free images from the acquired under-sampled data. However, an increasing number of receiver coils has raised the computational demands of pMRI techniques to an extent where the reconstruction time on general purpose computers becomes impractically long for real-time MRI. Field Programmable Gate Arrays (FPGAs) have recently emerged as a viable hardware platform for accelerating pMRI algorithms (e.g. SENSE). However, recent efforts to accelerate SENSE using FPGAs have been focused on a fixed number of receiver coils (L=8) and acceleration factor (Af=2). This paper presents a novel 32-bit floating-point FPGA-based hardware accelerator for SENSE (HW-ACC-SENSE); having an ability to work in coordination with an on-chip ARM processor performing reconstructions for different values of L and Af. Moreover, the proposed design provides flexibility to integrate multiple units of HW-ACC-SENSE with an on-chip ARM processor, for low-latency image reconstruction. The VIVADO High-Level-Synthesis (HLS) tool has been used to design and implement the HW-ACC-SENSE on the Xilinx FPGA development board (ZCU102). A series of experiments has been performed on in-vivo datasets acquired using 8, 12 and 30 receiver coil elements. The performance of the proposed architecture is compared with the single thread and multi-thread CPU-based implementations of SENSE. The results show that the proposed design withstands the reconstruction quality of the SENSE algorithm while demonstrating a maximum speed-gain up to 298× over the CPU counterparts in our experiments.
Collapse
|
41
|
Özen AC, Silemek B, Lottner T, Atalar E, Bock M. MR safety watchdog for active catheters: Wireless impedance control with real-time feedback. Magn Reson Med 2020; 84:1048-1060. [PMID: 31961965 DOI: 10.1002/mrm.28153] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/29/2019] [Accepted: 12/09/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE To dynamically minimize radiofrequency (RF)-induced heating of an active catheter through an automatic change of the termination impedance. METHODS A prototype wireless module was designed that modifies the input impedance of an active catheter to keep the temperature rise during MRI below a threshold, ΔTmax . The wireless module (MR safety watchdog; MRsWD) measures the local temperature at the catheter tip using either a built-in thermistor or external data from a fiber-optical thermometer. It automatically changes the catheter input impedance until the temperature rise during MRI is minimized. If ΔTmax is exceeded, RF transmission is blocked by a feedback system. RESULTS The thermistor and fiber-optical thermometer provided consistent temperature data in a phantom experiment. During MRI, the MRsWD was able to reduce the maximum temperature rise by 25% when operated in real-time feedback mode. CONCLUSION This study demonstrates the technical feasibility of an MRsWD as an alternative or complementary approach to reduce RF-induced heating of active interventional devices. The automatic MRsWD can reduce heating using direct temperature measurements at the tip of the catheter. Given that temperature measurements are intrinsically slow, for a clinical implementation, a faster feedback parameter would be required such as the RF currents along the catheter or scattered electric fields at the tip.
Collapse
Affiliation(s)
- Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany.,Faculty of Medicine, University of Freiburg, Freiburg, Germany.,German Consortium for Translational Cancer Research Partner Site Freiburg, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Berk Silemek
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany
| | - Thomas Lottner
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany
| | - Ergin Atalar
- National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey.,Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey
| | - Michael Bock
- Department of Radiology, Medical Physics, Medical Center - University of Freiburg, Freiburg, Germany
| |
Collapse
|
42
|
Godinez F, Scott G, Padormo F, Hajnal JV, Malik SJ. Safe guidewire visualization using the modes of a PTx transmit array MR system. Magn Reson Med 2019; 83:2343-2355. [PMID: 31722119 PMCID: PMC7048617 DOI: 10.1002/mrm.28069] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 10/16/2019] [Accepted: 10/16/2019] [Indexed: 02/06/2023]
Abstract
Purpose MRI‐guided cardiovascular intervention using standard metal guidewires can produce focal tissue heating caused by induced radiofrequency guidewire currents. It has been shown that safe operation is made possible by using parallel transmit radiofrequency coils driven in the null current mode, which does not induce radiofrequency currents and hence allows safe tissue visualization. We propose that the maximum current modes, usually considered unsafe, be used at very low power levels to visualize conductive wires, and we investigate pulse sequences best suited for this application. Methods Spoiled gradient echo, balanced steady‐state free precession, and turbo spin echo sequences were evaluated for their ability to visualize a conductive guidewire embedded in a gel phantom when run in maximum current modes at very low power level. Temperature at the guidewire tip was monitored for safety assessment. Results Excellent guidewire visualization could be achieved using maximum current modes excitation, with the turbo spin echo sequence giving the best image quality. Although turbo spin echo is usually considered to be a high‐power sequence, our method reduced all pulses to 1% amplitude (0.01% power), and heating was not detected. In addition, visualization of background tissue can be achieved using null current mode, also with no recorded heating at the guidewire tip even when running at 100% (reported) specific absorption rate. Conclusion Parallel transmit is a promising approach for both guidewire and tissue visualization using maximum and null current modes, respectively, for interventional cardiac MRI. Such systems can switch excitation mode instantaneously, allowing for flexible integration into interactive sequences.
Collapse
Affiliation(s)
- Felipe Godinez
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Greig Scott
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | | | - Joseph V Hajnal
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Shaihan J Malik
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
43
|
Menchón-Lara RM, Simmross-Wattenberg F, Casaseca-de-la-Higuera P, Martín-Fernández M, Alberola-López C. Reconstruction techniques for cardiac cine MRI. Insights Imaging 2019; 10:100. [PMID: 31549235 PMCID: PMC6757088 DOI: 10.1186/s13244-019-0754-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 05/17/2019] [Indexed: 12/17/2022] Open
Abstract
The present survey describes the state-of-the-art techniques for dynamic cardiac magnetic resonance image reconstruction. Additionally, clinical relevance, main challenges, and future trends of this image modality are outlined. Thus, this paper aims to provide a general vision about cine MRI as the standard procedure in functional evaluation of the heart, focusing on technical methodologies.
Collapse
Affiliation(s)
- Rosa-María Menchón-Lara
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain.
| | - Federico Simmross-Wattenberg
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Pablo Casaseca-de-la-Higuera
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Marcos Martín-Fernández
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Carlos Alberola-López
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| |
Collapse
|
44
|
Grant EK, Kanter JP, Olivieri LJ, Cross RR, Campbell-Washburn A, Faranesh AZ, Cronin I, Hamann KS, O’Byrne ML, Slack MC, Lederman RJ, Ratnayaka K. X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions. Catheter Cardiovasc Interv 2019; 94:399-408. [PMID: 31062506 PMCID: PMC6823111 DOI: 10.1002/ccd.28324] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 03/15/2019] [Accepted: 04/14/2019] [Indexed: 11/10/2022]
Abstract
OBJECTIVES To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.
Collapse
Affiliation(s)
- Elena K. Grant
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Joshua P. Kanter
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Laura J. Olivieri
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Russell R. Cross
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Adrienne Campbell-Washburn
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Anthony Z. Faranesh
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Ileen Cronin
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Karin S. Hamann
- Department of Cardiology, Children’s National Medical Center, Washington, District of Columbia
| | - Michael L. O’Byrne
- Divison of Cardiology, The Children’s Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Michael C. Slack
- Children’s Heart Program, University of Maryland Children’s Heart Program, Baltimore, Maryland
| | - Robert J. Lederman
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
| | - Kanishka Ratnayaka
- Division of Intramural Research, Cardiovascular Branch, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland
- Department of Cardiology, Rady Children’s Hospital, San Diego, California
| |
Collapse
|
45
|
Okada DR, Wu KC. Applications of Cardiac MR Imaging in Electrophysiology. Magn Reson Imaging Clin N Am 2019; 27:465-473. [PMID: 31279450 DOI: 10.1016/j.mric.2019.04.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
46
|
Mukherjee RK, Whitaker J, Williams SE, Razavi R, O'Neill MD. Magnetic resonance imaging guidance for the optimization of ventricular tachycardia ablation. Europace 2019; 20:1721-1732. [PMID: 29584897 PMCID: PMC6212773 DOI: 10.1093/europace/euy040] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Accepted: 02/19/2018] [Indexed: 01/02/2023] Open
Abstract
Catheter ablation has an important role in the management of patients with ventricular tachycardia (VT) but is limited by modest long-term success rates. Magnetic resonance imaging (MRI) can provide valuable anatomic and functional information as well as potentially improve identification of target sites for ablation. A major limitation of current MRI protocols is the spatial resolution required to identify the areas of tissue responsible for VT but recent developments have led to new strategies which may improve substrate assessment. Potential ways in which detailed information gained from MRI may be utilized during electrophysiology procedures include image integration or performing a procedure under real-time MRI guidance. Image integration allows pre-procedural magnetic resonance (MR) images to be registered with electroanatomical maps to help guide VT ablation and has shown promise in preliminary studies. However, multiple errors can arise during this process due to the registration technique used, changes in ventricular geometry between the time of MRI and the ablation procedure, respiratory and cardiac motion. As isthmus sites may only be a few millimetres wide, reducing these errors may be critical to improve outcomes in VT ablation. Real-time MR-guided intervention has emerged as an alternative solution to address the limitations of pre-acquired imaging to guide ablation. There is now a growing body of literature describing the feasibility, techniques, and potential applications of real-time MR-guided electrophysiology. We review whether real-time MR-guided intervention could be applied in the setting of VT ablation and the potential challenges that need to be overcome.
Collapse
Affiliation(s)
- Rahul K Mukherjee
- School of Biomedical Engineering and Imaging Sciences, 4th Floor, North Wing, St Thomas' Hospital, King's College London, London, UK
| | - John Whitaker
- School of Biomedical Engineering and Imaging Sciences, 4th Floor, North Wing, St Thomas' Hospital, King's College London, London, UK
| | - Steven E Williams
- School of Biomedical Engineering and Imaging Sciences, 4th Floor, North Wing, St Thomas' Hospital, King's College London, London, UK.,Department of Cardiology, Guy's and St Thomas' Hospital NHS Foundation Trust, London, UK
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, 4th Floor, North Wing, St Thomas' Hospital, King's College London, London, UK
| | - Mark D O'Neill
- School of Biomedical Engineering and Imaging Sciences, 4th Floor, North Wing, St Thomas' Hospital, King's College London, London, UK.,Department of Cardiology, Guy's and St Thomas' Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
47
|
Mukherjee RK, Chubb H, Roujol S, Razavi R, O'Neill MD. Advances in Real-Time MRI-Guided Electrophysiology. CURRENT CARDIOVASCULAR IMAGING REPORTS 2019; 12:6. [PMID: 31501689 PMCID: PMC6733706 DOI: 10.1007/s12410-019-9481-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Purpose of Review Theoretical benefits of real-time MRI guidance over conventional electrophysiology include contemporaneous 3D substrate assessment and accurate intra-procedural guidance and evaluation of ablation lesions. We review the unique challenges inherent to MRI-guided electrophysiology and how to translate the potential benefits in the treatment of cardiac arrhythmias. Recent Findings Over the last 5 years, there has been substantial progress, initially in animal models and more recently in clinical studies, to establish methods and develop workflows within the MR environment that resemble those of conventional electrophysiology laboratories. Real-time MRI-guided systems have been used to perform electroanatomic mapping and ablation in patients with atrial flutter, and there is interest in developing the technology to tackle more complex arrhythmias including atrial fibrillation and ventricular tachycardia. Summary Mainstream adoption of real-time MRI-guided electrophysiology will require demonstration of clinical benefit and will be aided by increased availability of devices suitable for use in the MRI environment.
Collapse
Affiliation(s)
- Rahul K Mukherjee
- School of Biomedical Engineering and Imaging Sciences, King's College London, 4th Floor, North Wing, St Thomas' Hospital, London SE1 7EH, UK
| | - Henry Chubb
- School of Biomedical Engineering and Imaging Sciences, King's College London, 4th Floor, North Wing, St Thomas' Hospital, London SE1 7EH, UK
| | - Sébastien Roujol
- School of Biomedical Engineering and Imaging Sciences, King's College London, 4th Floor, North Wing, St Thomas' Hospital, London SE1 7EH, UK
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, King's College London, 4th Floor, North Wing, St Thomas' Hospital, London SE1 7EH, UK
| | - Mark D O'Neill
- School of Biomedical Engineering and Imaging Sciences, King's College London, 4th Floor, North Wing, St Thomas' Hospital, London SE1 7EH, UK.,Department of Cardiology, King's College Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
48
|
Wang T, Xiong J, Xu X, Jiang M, Yuan H, Huang M, Zhuang J, Shi Y. MSU-Net: Multiscale Statistical U-Net for Real-Time 3D Cardiac MRI Video Segmentation. LECTURE NOTES IN COMPUTER SCIENCE 2019. [DOI: 10.1007/978-3-030-32245-8_68] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
49
|
Bock M, Traser L, Caglar Özen A, Burdumy M, Richter B, Echternach M. Reply to Letter to the Editor: "Nomenclature for real-time magnetic resonance imaging". Magn Reson Med 2018; 81:1485. [PMID: 30450633 DOI: 10.1002/mrm.27599] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Accepted: 10/17/2018] [Indexed: 12/29/2022]
Affiliation(s)
- Michael Bock
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Germany.,Faculty of Medicine, University of Freiburg, Germany
| | - Louisa Traser
- Faculty of Medicine, University of Freiburg, Germany.,Institute of Musicians' Medicine, Medical Center - University of Freiburg, Germany.,Department of Otolaryngology, Medical Center - University of Freiburg, Germany
| | - Ali Caglar Özen
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Germany.,Faculty of Medicine, University of Freiburg, Germany
| | - Michael Burdumy
- Dept. of Radiology, Medical Physics, Medical Center - University of Freiburg, Germany.,Faculty of Medicine, University of Freiburg, Germany
| | - Bernhard Richter
- Faculty of Medicine, University of Freiburg, Germany.,Institute of Musicians' Medicine, Medical Center - University of Freiburg, Germany.,Department of Otolaryngology, Medical Center - University of Freiburg, Germany
| | - Matthias Echternach
- Faculty of Medicine, University of Freiburg, Germany.,Institute of Musicians' Medicine, Medical Center - University of Freiburg, Germany.,Department of Otolaryngology, Medical Center - University of Freiburg, Germany
| |
Collapse
|
50
|
Dietz B, Fallone BG, Wachowicz K. Nomenclature for real‐time magnetic resonance imaging. Magn Reson Med 2018; 81:1483-1484. [DOI: 10.1002/mrm.27487] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 07/11/2018] [Accepted: 07/18/2018] [Indexed: 12/15/2022]
Affiliation(s)
- Bryson Dietz
- Division of Medical Physics, Department of Oncology University of Alberta, Cross Cancer Institute Edmonton Canada
| | - B. Gino Fallone
- Department of Medical Physics Cross Cancer Institute Edmonton Canada
- Departments of Oncology and Physics University of Alberta Edmonton Canada
| | - Keith Wachowicz
- Department of Medical Physics Cross Cancer Institute Edmonton Canada
- Departments of Oncology and Physics University of Alberta Edmonton Canada
| |
Collapse
|