1
|
Kakkar S, Gupta P, Singh Yadav SP, Raj D, Singh G, Chauhan S, Mishra MK, Martín-Ortega E, Chiussi S, Kant K. Lateral flow assays: Progress and evolution of recent trends in point-of-care applications. Mater Today Bio 2024; 28:101188. [PMID: 39221210 PMCID: PMC11364909 DOI: 10.1016/j.mtbio.2024.101188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 07/20/2024] [Accepted: 08/05/2024] [Indexed: 09/04/2024] Open
Abstract
Paper based point-of-care (PoC) detection platforms applying lateral flow assays (LFAs) have gained paramount approval in the diagnostic domain as well as in environmental applications owing to their ease of utility, low cost, and rapid signal readout. It has centralized the aspect of self-evaluation exhibiting promising potential in the last global pandemic era of Covid-19 implementing rapid management of public health in remote areas. In this perspective, the present review is focused towards landscaping the current framework of LFAs along with integration of components and characteristics for improving the assay by pushing the detection limits. The review highlights the synergistic aspects of assay designing, sample enrichment strategies, novel nanomaterials-based signal transducers, and high-end analytical techniques that contribute significantly towards sensitivity and specificity enhancement. Various recent studies are discussed supporting the innovations in LFA systems that focus upon the accuracy and reliability of rapid PoC testing. The review also provides a comprehensive overview of all the possible difficulties in commercialization of LFAs subjecting its applicability to pathogen surveillance, water and food testing, disease diagnostics, as well as to agriculture and environmental issues.
Collapse
Affiliation(s)
- Saloni Kakkar
- Council of Scientific and Industrial Research (CSIR)- Centre for Cellular & Molecular Biology (CCMB), Hyderabad, 500007, India
| | - Payal Gupta
- Department of Biotechnology, Graphic Era (Deemed to be University), Dehradun, 248002, India
| | - Shiv Pratap Singh Yadav
- Council of Scientific and Industrial Research (CSIR)- Centre for Cellular & Molecular Biology (CCMB), Hyderabad, 500007, India
| | - Divakar Raj
- Department of Allied Sciences, School of Health Sciences and Technology, UPES, Dehradun, 248007, India
| | - Garima Singh
- Department of Allied Sciences, School of Health Sciences and Technology, UPES, Dehradun, 248007, India
| | - Sakshi Chauhan
- Dept. of Cardiothoracic and Vascular Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, 160012, India
| | | | - Elena Martín-Ortega
- IFCAE, Research Institute of Physics and Aerospace Science, Universidade de Vigo, Ourense, 32004, Spain
| | - Stefano Chiussi
- CINTECX, Universidade de Vigo, New Materials Group, Vigo, 36310, Spain
| | - Krishna Kant
- CINBIO, Universidade de Vigo, Campus Universitario As Lagoas Marcosende, Vigo, 36310, Spain
- Department of Biotechnology, School of Engineering and Applied Sciences, Bennett University, Greater Noida, U.P., India
| |
Collapse
|
2
|
Kim MJ, Haizan I, Ahn MJ, Park DH, Choi JH. Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors. BIOSENSORS 2024; 14:197. [PMID: 38667190 PMCID: PMC11048458 DOI: 10.3390/bios14040197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/12/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024]
Abstract
Controlling the progression of contagious diseases is crucial for public health management, emphasizing the importance of early viral infection diagnosis. In response, lateral flow assays (LFAs) have been successfully utilized in point-of-care (POC) testing, emerging as a viable alternative to more traditional diagnostic methods. Recent advancements in virus detection have primarily leveraged methods such as reverse transcription-polymerase chain reaction (RT-PCR), reverse transcription-loop-mediated isothermal amplification (RT-LAMP), and the enzyme-linked immunosorbent assay (ELISA). Despite their proven effectiveness, these conventional techniques are often expensive, require specialized expertise, and consume a significant amount of time. In contrast, LFAs utilize nanomaterial-based optical sensing technologies, including colorimetric, fluorescence, and surface-enhanced Raman scattering (SERS), offering quick, straightforward analyses with minimal training and infrastructure requirements for detecting viral proteins in biological samples. This review describes the composition and mechanism of and recent advancements in LFAs for viral protein detection, categorizing them into colorimetric, fluorescent, and SERS-based techniques. Despite significant progress, developing a simple, stable, highly sensitive, and selective LFA system remains a formidable challenge. Nevertheless, an advanced LFA system promises not only to enhance clinical diagnostics but also to extend its utility to environmental monitoring and beyond, demonstrating its potential to revolutionize both healthcare and environmental safety.
Collapse
Affiliation(s)
- Min Jung Kim
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
| | - Izzati Haizan
- Department of Bioprocess Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea;
| | - Min Ju Ahn
- Department of Biotechnology, Jeonbuk National University, 79 Gobongro, Iksan-si 54596, Jeollabuk-do, Republic of Korea;
| | - Dong-Hyeok Park
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
| | - Jin-Ha Choi
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
- Department of Bioprocess Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea;
| |
Collapse
|
3
|
Lu P, Zhan C, Huang C, Miao L, Chen R, Zhao Y, Xianyu Y, Chen X, Chen Y. A Wash-Free Spheres-on-Sphere Strategy for On-Site and Multiplexed Biosensing. ACS NANO 2024; 18:8270-8282. [PMID: 38451231 DOI: 10.1021/acsnano.3c12289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
Respiratory infections and food contaminants pose severe challenges to global health and the economy. A rapid on-site platform for the simultaneous detection of multiple pathogens is crucial for accurate diagnosis, appropriate treatment, and a reduced healthcare burden. Herein, we present a spheres-on-sphere (SOS) platform for multiplexed detection using a portable Coulter counter, which employs millimeter- and micron-sized spheres coupled with antibodies as multitarget probes. The assay allows for quantitative detection of multiple analytes within 20 min by simple mixing, enabling on-site detection. The platform shows high accuracy in identifying three respiratory viruses (SARS-CoV-2, influenza A virus, and parainfluenza virus) from throat swab samples, with LOD of 50.7, 32.4, and 49.1 pg/mL. It also demonstrates excellent performance in quantifying three mycotoxins (aflatoxin B1, deoxynivalenol, and ochratoxin A) from food samples. The SOS platform offers a rapid on-site approach with high sensitivity and specificity for applications in resource-limited settings.
Collapse
Affiliation(s)
- Peng Lu
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Chen Zhan
- College of Informatics, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Chenxi Huang
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Lin Miao
- The First School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
| | - Rui Chen
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Yongkun Zhao
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Yunlei Xianyu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, Zhejiang, China
| | - Xiaohua Chen
- The First School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
| | - Yiping Chen
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
- State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China
| |
Collapse
|
4
|
Qiao W, He B, Yang J, Ren W, Zhao R, Zhang Y, Bai C, Suo Z, Xu Y, Wei M, Jin H. Pt@AuNF nanozyme and horseradish peroxidase-based lateral flow immunoassay dual enzymes signal amplification strategy for sensitive detection of zearalenone. Int J Biol Macromol 2024; 254:127746. [PMID: 37923041 DOI: 10.1016/j.ijbiomac.2023.127746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/24/2023] [Accepted: 10/26/2023] [Indexed: 11/07/2023]
Abstract
Lateral flow immunoassay (LFIA) has been employed extensively for the rapid, accurate, and portable detection of foodborne toxins. Here, the platinum gold nanoflower core-shell (Pt@AuNF) nanozyme with excellent optical properties, good catalytic ability and controllable reaction conditions were prepared to effectively improve the performance of lateral flow immunoassay (LFIA) strips. The Pt@AuNF nanozyme and horseradish peroxidase (HRP) combined with monoclonal antibody were used as signal probes based on the dual enzymes catalytic signal amplification strategy to detect Zearalenone sensitively. Dual enzymes catalyze the decomposition of hydrogen peroxide into hydroxyl radicals, and under the influence of hydroxyl radicals, colorless 3,3',5,5' -tetramethylbenzidine (TMB) is oxidized to blue ox-TMB, which is superimposed on the strips for signal amplification to broaden the detection range. The limit of detection (LOD) of the Pt@AuNF-HRP labeled LFIA strips after signal amplification was 0.052 ng/mL, and the detection range was 0.052-7.21 ng/mL. Compared with the Pt@AuNF labeled strips, while reducing the probes amount by half to achieve antibody conservation, the detection range was expanded by 5-fold based on achieving improved sensitivity. The study provided a meaningful reference for expanding the detection range based on immunoassay.
Collapse
Affiliation(s)
- Weili Qiao
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Baoshan He
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China.
| | - Jun Yang
- Department of Entomology, University of California, Davis, CA 95616, United States
| | - Wenjie Ren
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Renyong Zhao
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Yurong Zhang
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou, Henan 450001, PR China.
| | - Chunqi Bai
- School of Food and Strategic Reserves, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Zhiguang Suo
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Yiwei Xu
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Min Wei
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Huali Jin
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| |
Collapse
|
5
|
Link JS, Carrell CS, Jang I, Barstis EJO, Call ZD, Bellows RA, O'Donnell-Sloan JJ, Terry JS, Anderson LBR, Panraksa Y, Geiss BJ, Dandy DS, Henry CS. Capillary flow-driven immunoassay platform for COVID-19 antigen diagnostics. Anal Chim Acta 2023; 1277:341634. [PMID: 37604607 PMCID: PMC10476143 DOI: 10.1016/j.aca.2023.341634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 07/14/2023] [Accepted: 07/15/2023] [Indexed: 08/23/2023]
Abstract
Over the last few years, the SARS-CoV-2 pandemic has made the need for rapid, affordable diagnostics more compelling than ever. While traditional laboratory diagnostics like PCR and well-plate ELISA are sensitive and specific, they can be costly and take hours to complete. Diagnostic tests that can be used at the point-of-care or at home, like lateral flow assays (LFAs) are a simple, rapid alternative, but many commercially available LFAs have been criticized for their lack of sensitivity compared to laboratory methods like well-plate ELISAs. The Capillary-Driven Immunoassay (CaDI) device described in this work uses microfluidic channels and capillary action to passively automate the steps of a traditional well-plate ELISA for visual read out. This work builds on prior capillary-flow devices by further simplifying operation and use of colorimetric detection. Upon adding sample, an enzyme-conjugated secondary antibody, wash steps, and substrate are sequentially delivered to test and control lines on a nitrocellulose strip generating a colorimetric response. The end user can visually detect SARS-CoV-2 antigen in 15-20 min by naked eye, or results can be quantified using a smartphone and software such as ImageJ. An analytical detection limit of 83 PFU/mL for SARS-CoV-2 was determined for virus in buffer, and 222 PFU/mL for virus spiked into nasal swabs using image analysis, similar to the LODs determined by traditional well-plate ELISA. Additionally, a visual detection limit of 100 PFU/mL was determined in contrived nasal swab samples by polling 20 untrained end-users. While the CaDI device was used for detecting clinically relevant levels of SARS-CoV-2 in this study, the CaDI device can be easily adapted to other immunoassay applications by changing the reagents and antibodies.
Collapse
Affiliation(s)
- Jeremy S Link
- Department of Chemistry, Colorado State University, USA
| | | | - Ilhoon Jang
- Department of Chemistry, Colorado State University, USA; Institute of Nano Science and Technology, Hanyang University, South Korea
| | | | | | - Rae A Bellows
- Department of Chemistry, Colorado State University, USA
| | | | - James S Terry
- Department of Microbiology, Immunology and Pathology, Colorado State University, USA
| | - Loran B R Anderson
- Department of Microbiology, Immunology and Pathology, Colorado State University, USA
| | - Yosita Panraksa
- Department of Microbiology, Immunology and Pathology, Colorado State University, USA; Myobacteria Research Laboratories, Colorado State University, USA
| | - Brian J Geiss
- Department of Microbiology, Immunology and Pathology, Colorado State University, USA; School of Biomedical Engineering, Colorado State University, USA
| | - David S Dandy
- Department of Chemical and Biological Engineering, Colorado State University, USA; School of Biomedical Engineering, Colorado State University, USA
| | - Charles S Henry
- Department of Chemistry, Colorado State University, USA; Department of Chemical and Biological Engineering, Colorado State University, USA; School of Biomedical Engineering, Colorado State University, USA; Metalluragy and Materials Research Institute, Chulalongkorn University, Bangkok, Thailand.
| |
Collapse
|
6
|
Panferov VG, Zherdev AV, Dzantiev BB. Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review. BIOSENSORS 2023; 13:866. [PMID: 37754100 PMCID: PMC10526817 DOI: 10.3390/bios13090866] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/15/2023] [Accepted: 08/23/2023] [Indexed: 09/28/2023]
Abstract
Lateral flow immunoassay (LFIA) has found a broad application for testing in point-of-care (POC) settings. LFIA is performed using test strips-fully integrated multimembrane assemblies containing all reagents for assay performance. Migration of liquid sample along the test strip initiates the formation of labeled immunocomplexes, which are detected visually or instrumentally. The tradeoff of LFIA's rapidity and user-friendliness is its relatively low sensitivity (high limit of detection), which restricts its applicability for detecting low-abundant targets. An increase in LFIA's sensitivity has attracted many efforts and is often considered one of the primary directions in developing immunochemical POC assays. Post-assay enhancements based on chemical reactions facilitate high sensitivity. In this critical review, we explain the performance of post-assay chemical enhancements, discuss their advantages, limitations, compared limit of detection (LOD) improvements, and required time for the enhancement procedures. We raise concerns about the performance of enhanced LFIA and discuss the bottlenecks in the existing experiments. Finally, we suggest the experimental workflow for step-by-step development and validation of enhanced LFIA. This review summarizes the state-of-art of LFIA with chemical enhancement, offers ways to overcome existing limitations, and discusses future outlooks for highly sensitive testing in POC conditions.
Collapse
Affiliation(s)
- Vasily G. Panferov
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
- Department of Chemistry, York University, Toronto, ON M3J 1P3, Canada
| | - Anatoly V. Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| | - Boris B. Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| |
Collapse
|
7
|
Ijadi Bajestani M, Ahmadzadeh H. Modified polysulfone membrane facilitates rapid separation of plasma from whole blood for an effective anti-SARS-CoV-2-IgM diagnosis. Sci Rep 2023; 13:13712. [PMID: 37608047 PMCID: PMC10444766 DOI: 10.1038/s41598-023-40871-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Accepted: 08/17/2023] [Indexed: 08/24/2023] Open
Abstract
During the outbreak of coronavirus, RT-PCR was the premier gold standard method for severe acute respiratory syndrome coronavirus 2 (SARSCoV-2) diagnosis. However, the sophisticated procedure of RT-PCR persuades researchers to develop sustainable point-of-need immunoassay methods for tracing unwitting carriers of SARSCoV-2. Herein, by fabricating a modified polysulfone (MPSF) membrane, we developed an integrated radial flow immunoassay (IRFIA) platform as a point-of-care system, capable of multiplying the immunoassays at a short run time. The target molecule is the SARSCoV-2 IgM in separated plasma. Although the lateral flow immunoassay kits for the rapid identification of Covid-19 have already been commercially developed but, the proposed method is superior to the conventional lateral flow immunoassay. In the newly designed membrane system, we have combined the five membranes of prevalent lateral flow immunoassay (LFIA) strips in one polymeric membrane. The MPSF membrane is capable of separating plasma from whole blood sample, which will reduce the interference of red colour of hemoglobin with generated signal and enhance the immunoassay precision. The efficiency of plasma separation, reached the mean value of 97.34 v/v% in 5 s. Furthermore, the gel electrophoresis results of the separated plasma contrasted with centrifuged plasma sample, demonstrated more efficient separation by the membrane. Using the MPSF membrane, signal generation time reduced from about 20 min in conventional rapid test strip for Covid-19 to about 7 min in IRFIA platform. The sensitivity and specificity of the membrane platform were determined to be 89% and 90%, respectively and a Kappa coefficient of 0.79 showed reliable agreement between the RT-PCR and the membrane system.
Collapse
Affiliation(s)
- Maryam Ijadi Bajestani
- Faculty of Science, Department of Chemistry, Ferdowsi University of Mashhad, Mashhad, 9177948974, Iran
| | - Hossein Ahmadzadeh
- Faculty of Science, Department of Chemistry, Ferdowsi University of Mashhad, Mashhad, 9177948974, Iran.
| |
Collapse
|
8
|
Boegner DJ, Everitt ML, White IM. Thermally Responsive Alkane Partitions for Assay Automation. ACS APPLIED MATERIALS & INTERFACES 2022; 14:8865-8875. [PMID: 35147027 PMCID: PMC10044609 DOI: 10.1021/acsami.2c00493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
For point-of-care diagnostic tools to be impactful, they must be inexpensive, equipment-free, and sample-to-answer (i.e., require no user intervention). Here, we report a new approach to enable sample-to-answer diagnostics that utilizes thermally responsive alkane partitions (TRAPs) as automated pseudo-valves. When combined with the magnetic manipulation of microbeads, TRAPs enable the pumpless automation of all steps in complex assays. We demonstrate that in relatively narrow channel geometries, liquified alkane partitions continue to separate reagents on each side of the partition while enabling the transition of magnetic beads from one reagent to the next, replacing manual pipetting steps in conventional assays. In addition, we show that in relatively broader geometries, liquified partitions breach, enabling the addition/mixing of preloaded reagents. Through calculation and experimentation, we determine the geometric design rules for implementing the stationary and removable partitions in fluidic channels. In addition, we demonstrate that magnetic microbeads can be pulled through liquified stationary TRAPs without disrupting partition integrity and without disrupting bound protein complexes attached at the microbead surface. The TRAP technology introduced here can enable a new low-cost and equipment-free approach for fully automated sample-to-answer diagnostics.
Collapse
Affiliation(s)
- David J Boegner
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Micaela L Everitt
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| | - Ian M White
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, Maryland 20742, United States
| |
Collapse
|
9
|
Kim S, Sikes HD. Dual Photoredox Catalysis Strategy for Enhanced Photopolymerization-Based Colorimetric Biodetection. ACS APPLIED MATERIALS & INTERFACES 2021; 13:57962-57970. [PMID: 34797978 DOI: 10.1021/acsami.1c17589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Catalytic redox reactions have been employed to enhance colorimetric biodetection signals in point-of-care diagnostic tests, while their time-sensitive visual readouts may increase the risk of false results. To address this issue, we developed a dual photocatalyst signal amplification strategy that can be controlled by a fixed light dose, achieving time-independent colorimetric biodetection in paper-based tests. In this method, target-associated methylene blue (MB+) photocatalytically amplifies the concentration of eosin Y by oxidizing deactivated eosin Y (EYH3-) under red light, followed by photopolymerization with eosin Y autocatalysis under green light to generate visible hydrogels. Using the insights from mechanistic studies on MB+-sensitized photo-oxidation of EYH3-, we improved the photocatalytic efficiency of MB+ by suppressing its degradation. Lastly, we characterized 100- to 500-fold enhancement in sensitivity obtained from MB+-specific eosin Y amplification, highlighting the advantages of using dual photocatalyst signal amplification.
Collapse
Affiliation(s)
- Seunghyeon Kim
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Hadley D Sikes
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
- Antimicrobial Resistance Integrated Research Group, Singapore-MIT Alliance for Research and Technology, 1 CREATE Way, Singapore 138602, Singapore
| |
Collapse
|
10
|
Naseri M, Ziora ZM, Simon GP, Batchelor W. ASSURED‐compliant point‐of‐care diagnostics for the detection of human viral infections. Rev Med Virol 2021. [DOI: 10.1002/rmv.2263] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Mahdi Naseri
- Department of Chemical Engineering Bioresource Processing Research Institute of Australia (BioPRIA) Monash University Clayton VIC Australia
| | - Zyta M Ziora
- Institute for Molecular Bioscience The University of Queensland St Lucia QLD Australia
| | - George P Simon
- Department of Materials Science and Engineering Monash University Clayton VIC Australia
| | - Warren Batchelor
- Department of Chemical Engineering Bioresource Processing Research Institute of Australia (BioPRIA) Monash University Clayton VIC Australia
| |
Collapse
|
11
|
Farre C, Viezzi S, Wright A, Robin P, Lejal N, Manzano M, Vidic J, Chaix C. Specific and sensitive detection of Influenza A virus using a biotin-coated nanoparticle enhanced immunomagnetic assay. Anal Bioanal Chem 2020; 414:265-276. [PMID: 33230699 PMCID: PMC7682758 DOI: 10.1007/s00216-020-03081-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 11/04/2020] [Accepted: 11/17/2020] [Indexed: 10/27/2022]
Abstract
This study reports the development of a sensitive magnetic bead-based enzyme-linked immunoassay (MELISA) for the pan-reactive detection of the Influenza A virus. The assay combines immunomagnetic beads and biotin-nanoparticle-based detection to quantify a highly conserved viral nucleoprotein in virus lysates. At the capture step, monoclonal antibody-coated magnetic microbeads were used to bind and concentrate the nucleoprotein in samples. The colorimetric detection signal was amplified using biotinylated silica nanoparticles (NP). These nanoparticles were functionalized on the surface with short DNA spacers bearing biotin groups by an automated supported synthesis method performed on nano-on-micro assemblies with a DNA/RNA synthesizer. A biotin-nanoparticle and immunomagnetic bead-based assay was developed. We succeeded in detecting Influenza A viruses directly in the lysis buffer supplemented with 10% saliva to simulate the clinical context. The biotin-nanoparticle amplification step enabled detection limits as low as 3 × 103 PFU mL-1 and 4 × 104 PFU mL-1 to be achieved for the H1N1 and H3N2 strains respectively. In contrast, a classical ELISA test based on the same antibody sandwich showed detection limit of 1.2 × 107 PFU mL-1 for H1N1. The new enhanced MELISA proved to be specific, as no cross-reactivity was found with a porcine respiratory virus (PRRSV). Graphical abstract.
Collapse
Affiliation(s)
- Carole Farre
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Sara Viezzi
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France.,Dipartimento di Scienze Agro-Alimentari, Ambientali e Animali, Università degli Studi di Udine, via Sondrio 2/A, 33100, Udine, Italy
| | - Alice Wright
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Perrine Robin
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Nathalie Lejal
- Université Paris-Saclay, UR892, INRAE, 78350, Jouy-en-Josas, France
| | - Marisa Manzano
- Dipartimento di Scienze Agro-Alimentari, Ambientali e Animali, Università degli Studi di Udine, via Sondrio 2/A, 33100, Udine, Italy
| | - Jasmina Vidic
- Université Paris-Saclay, INRAE, AgroParisTech, Micalis Institute, 78350, Jouy-en-Josas, France
| | - Carole Chaix
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, 69100, Villeurbanne, France.
| |
Collapse
|
12
|
Evaluation of Lateral-Flow Assay for Rapid Detection of Influenza Virus. BIOMED RESEARCH INTERNATIONAL 2020; 2020:3969868. [PMID: 32964030 PMCID: PMC7495160 DOI: 10.1155/2020/3969868] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 08/11/2020] [Indexed: 12/22/2022]
Abstract
Background Influenza virus mainly causes acute respiratory infections in humans. However, the diagnosis of influenza is not accurate based on clinical evidence, as the symptoms of flu are similar to other respiratory virus. The lateral-flow assay is a rapid method to detect influenza virus. But the effectiveness of the technique in detecting flu viruses is unclear. Hence, a meta-analysis would be performed to evaluate the accuracy of LFA in detecting influenza virus. Methods Relevant literature was searched out in PubMed, Embase, Web of Science, and Cochrane Library databases with the keywords "lateral flow assay" and "flu virus". By Meta-DiSc software, pooled sensitivity, pooled specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver operating characteristic curve (SROC), and area under the curve (AUC) can be calculated. Results This meta-analysis contains 13 studies and 24 data. The pooled sensitivity and specificity of the influenza virus detected by LFA were 0.84 (95% CI: 0.82-0.86) and 0.97 (95% CI: 0.97-0.98), respectively. The pooled values of PLR, NLR, DOR, and SROC were 32.68 (17.16-62.24), 0.17 (0.13-0.24), 334.07 (144.27-773.53), and 0.9877. No publication bias was found. Conclusions LFA exhibited high sensitivity and specificity in diagnosing influenza virus. It is a valuable alternative method which can diagnose influenza virus quickly. However, more evidence is required to confirm whether LFA is comparable to traditional methods for detecting the virus.
Collapse
|
13
|
Axelrod T, Eltzov E, Marks RS. Capture-Layer Lateral Flow Immunoassay: A New Platform Validated in the Detection and Quantification of Dengue NS1. ACS OMEGA 2020; 5:10433-10440. [PMID: 32426600 PMCID: PMC7226885 DOI: 10.1021/acsomega.0c00367] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2020] [Accepted: 03/31/2020] [Indexed: 05/07/2023]
Abstract
The lateral flow immunoassay (LFIA) is the most successful point-of-care testing (POCT) method to date. In the case of clinical biomarkers that require quantification, it remains a challenge to quantitate those biomarkers using the lateral flow immunoassay remains a challenge due to the cost of the reader and possibly the type of marker used. In the present work, a new concept of a platform LFIA device configuration is proposed in which different, aligned membrane components, some already existing in the classical lateral flow immunoassay, and the others created with special new functions in the present device. As the sample containing the target analyte passes through the aforementioned membranes, the target analyte will initially interact with a target-specific antibody-conjugated to horseradish peroxidase (HRP). Thereafter, the newly formed immunocomplex will diffuse through a proprietary capture membrane (that ensures that the nontarget-bound antibodies do not continue further and thus remain "captured" to that specific area). This is done by having the target molecules (or components thereof) immobilized onto the said capture layer. The target-bound immunocomplexes will then be allowed by the system configuration to continue further to the last layer, where the signal will be generated and quantified. Thus, in the absence of the target analyte in the sample, the free antibodies will be filtered at the capture layer by preimmobilized analyte molecules, thus preventing a false positive signal to occur. We validated the concept in the detection of dengue NS1 protein in view of making a triage test. The sample containing NS1 will first meet HRP-conjugated NS1-specific antibodies and become attached, thus producing an NS1-specific antibody-HRP immunocomplex. The sample then flows through the blocking layer, where the immunocomplex is unchallenged and thus allowed to reach the last "absorbent" pad, incorporating the substrate for the HRP marker. In the case of a positive test, a signal is generated, that is proportional to the amount of immunocomplexes (and therefore the NS1 concentration), and then analyzed and measured at the absorbent pad. Any unbound anti-NS1 antibody will be stopped at the blocking matrix by preimmobilized NS1, so there will be no false positive. As this study is the initial study of a novel configuration, much of the work comprised of optimization steps, such as determining the required NS1 membrane-immobilization concentration and the required target-specific capture antibody concentration. Our immunoassay was tested with spiked buffer and serum samples to mimic the clinical conditions, with a range of NS1 concentrations, and was found, at this time, to be fivefold more sensitive than a gold standard enzyme-linked immunosorbent assay (ELISA) test (5 ng mL-1) performed in our laboratory. This method shows another form of LFIA that has the potential to be quantitative (at least semiquantitative), albeit not solving the reader cost; however, unlike the regular LFIA, we do not use nanobeads but instead enzymes, allowing, in theory, greater sensitivity, while retaining the one-step procedure. The test is accurate and has low production costs.
Collapse
Affiliation(s)
- Tim Axelrod
- Department
of Biotechnology Engineering, Faculty of Engineering Science, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
| | - Evgeni Eltzov
- Department
of Postharvest Science, Institute of Postharvest and Food Sciences, The Volcani Center, Agricultural Research Organization, Bet Dagan 50250, Israel
| | - Robert S. Marks
- Department
of Biotechnology Engineering, Faculty of Engineering Science, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
- National
Institute for Biotechnology in the Negev, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
- The
Ilse Katz Center for Meso and Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
| |
Collapse
|
14
|
Kim S, Sikes HD. Liposome-Enhanced Polymerization-Based Signal Amplification for Highly Sensitive Naked-Eye Biodetection in Paper-Based Sensors. ACS APPLIED MATERIALS & INTERFACES 2019; 11:28469-28477. [PMID: 31291078 DOI: 10.1021/acsami.9b08125] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Polymerization-based signal amplification (PBA) is a material-based approach to improving the sensitivity of paper-based diagnostic tests. Eosin Y is used as an assay label to photo-initiate free-radical polymerization to produce colored hydrogels in the presence of target analytes captured by bioactive paper. PBA achieves high-contrast and time-independent signals, but its nanomolar detection limit makes it impractical for early diagnosis of many diseases. In this work, we demonstrated efficient localization of large quantities of eosin Y per captured target analyte by incorporating eosin Y-loaded liposomes into PBA. This new "materials approach" allowed 30-fold signal enhancement compared to conventional PBA. To further improve the detection limit of liposome-enhanced PBA, we used a continuous flow-through assay format with 100 μL of analyte solution, achieving sub-nanomolar detection limits with high-contrast signals that were easily discernible to the unaided eye.
Collapse
Affiliation(s)
| | - Hadley D Sikes
- Antimicrobial Resistance Integrated Research Group , Singapore-MIT Alliance for Research and Technology , 1 Create Way 138602 , Singapore
| |
Collapse
|