1
|
Dong X, Zhang H, Duan P, Liu K, Yu Y, Wei W, Wang W, Liu Y, Cheng Q, Liang X, Huo Y, Yan L, Yu A, Dai H. An injectable and adaptable hydrogen sulfide delivery system for modulating neuroregenerative microenvironment. SCIENCE ADVANCES 2023; 9:eadi1078. [PMID: 38117891 PMCID: PMC10732521 DOI: 10.1126/sciadv.adi1078] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 11/17/2023] [Indexed: 12/22/2023]
Abstract
Peripheral nerve regeneration is a complex physiological process. Single-function nerve scaffolds often struggle to quickly adapt to the imbalanced regenerative microenvironment, leading to slow nerve regeneration and limited functional recovery. In this study, we demonstrate a "pleiotropic gas transmitter" strategy based on endogenous reactive oxygen species (ROS), which trigger the on-demand H2S release at the defect area for transected peripheral nerve injury (PNI) repair through concurrent neuroregeneration and neuroprotection processing. This H2S delivery system consists of an H2S donor (peroxyTCM) encapsulated in a ROS-responsive polymer (mPEG-PMet) and loaded into a temperature-sensitive poly (amino acid) hydrogel (mPEG-PA-PP). This multi-effect combination strategy greatly promotes the regeneration of PNI, attributed to the physiological effects of H2S. These effects include the inhibition of inflammation and oxidative stress, protection of nerve cells, promotion of angiogenesis, and the restoration of normal mitochondrial function. The adaptive release of pleiotropic messengers to modulate the tissue regeneration microenvironment offers promising peripheral nerve repair and tissue engineering opportunities.
Collapse
Affiliation(s)
- Xianzhen Dong
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Hao Zhang
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Ping Duan
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Kun Liu
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Yifeng Yu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Wenying Wei
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Weixing Wang
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Yuhang Liu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Qiang Cheng
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Xinyue Liang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Yuanfang Huo
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Lesan Yan
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
| | - Aixi Yu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
| | - Honglian Dai
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Biomedical Materials and Engineering Research Center of Hubei Province, Wuhan 430070, China
- Shenzhen Research Institute of Wuhan University of Technology, Shenzhen 518000, China
| |
Collapse
|
2
|
Xu C, Hong Y. Rational design of biodegradable thermoplastic polyurethanes for tissue repair. Bioact Mater 2022; 15:250-271. [PMID: 35386346 PMCID: PMC8940769 DOI: 10.1016/j.bioactmat.2021.11.029] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 11/09/2021] [Accepted: 11/24/2021] [Indexed: 12/25/2022] Open
Abstract
As a type of elastomeric polymers, non-degradable polyurethanes (PUs) have a long history of being used in clinics, whereas biodegradable PUs have been developed in recent decades, primarily for tissue repair and regeneration. Biodegradable thermoplastic (linear) PUs are soft and elastic polymeric biomaterials with high mechanical strength, which mimics the mechanical properties of soft and elastic tissues. Therefore, biodegradable thermoplastic polyurethanes are promising scaffolding materials for soft and elastic tissue repair and regeneration. Generally, PUs are synthesized by linking three types of changeable blocks: diisocyanates, diols, and chain extenders. Alternating the combination of these three blocks can finely tailor the physio-chemical properties and generate new functional PUs. These PUs have excellent processing flexibilities and can be fabricated into three-dimensional (3D) constructs using conventional and/or advanced technologies, which is a great advantage compared with cross-linked thermoset elastomers. Additionally, they can be combined with biomolecules to incorporate desired bioactivities to broaden their biomedical applications. In this review, we comprehensively summarized the synthesis, structures, and properties of biodegradable thermoplastic PUs, and introduced their multiple applications in tissue repair and regeneration. A whole picture of their design and applications along with discussions and perspectives of future directions would provide theoretical and technical supports to inspire new PU development and novel applications.
Collapse
Affiliation(s)
- Cancan Xu
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Yi Hong
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| |
Collapse
|
3
|
Hsu SH, Chang CJ, Tang CM, Lin FT. In Vitro and In Vivo Effects of Ginkgo biloba Extract EGb 761 on Seeded Schwann Cells within Poly(DL-lactic acid-co-glycolic acid) Conduits for Peripheral Nerve Regeneration. J Biomater Appl 2016; 19:163-82. [PMID: 15381788 DOI: 10.1177/0885328204045580] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study investigated the effects of Ginkgo biloba (EGb 761) extract on seeded Schwann cells within poly(DL-lactic acid-co-glycolic acid) (PLGA) conduits by in vitro and in vivo trials for peripheral nerve regeneration. The seeding efficiency of Schwann cells in serum-deprived culture medium, which simulated the environment of mechanical trauma on an injured nerve site, was improved by adding different dosages of EGb 761 (0, 1, 10, 20, 50, 100, 200 mg/mL). The analytical results showed enhanced cell attachment and survival, reduced LDH release and increased MTT values, particularly in the range 10-100 mg/mL. The PLGA nerve conduits seeded with Schwann cells (6 103 cells) and filled with gelatin containing EGb 761 (0, 10, 50, 100 mg/mL) were implanted to 10-mm right sciatic nerve defects in rats. Autograft was performed as another control. Electromyography was assessed based on the motor unit action potential (MUAP) and fibrillation potential (Fib) at 2, 4, and 6 weeks during all periods. The specimens of the experimental and control groups were harvested for histological analysis at 6 weeks after surgery. The Fib was found to gradually decay, and the MUAP was found not to be present until 4 weeks after surgery. Meanwhile, the experimental groups were all statically better than the control group (without EGb 761) and autografts were observed at 6 weeks, especially at the concentration of 10 mg/mL, where there was higher amplitude of MUAP and a significantly larger number of myelinated axons. This study concluded that a proper concentration of EGb 761 (10-50 mg/mL) promoted seeding efficiency of Schwann cells in a tissue-engineered PLGA conduit. Addition of EGb 761 in Schwann cells-seeded conduit could increase the total number of myelinated axons in nerve regeneration and improve peripheral nerve functional recovery.
Collapse
Affiliation(s)
- Shan-Hui Hsu
- Department of Chemical Engineering, National Chung Hsing University, Taichung, Taiwan.
| | | | | | | |
Collapse
|
4
|
Reichenberger MA, Mueller W, Hartmann J, Diehm Y, Lass U, Koellensperger E, Leimer U, Germann G, Fischer S. ADSCs in a fibrin matrix enhance nerve regeneration after epineural suturing in a rat model. Microsurgery 2015; 36:491-500. [DOI: 10.1002/micr.30018] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Revised: 11/14/2015] [Accepted: 12/08/2015] [Indexed: 01/05/2023]
Affiliation(s)
- Matthias A. Reichenberger
- ETHIANUM-Clinic for Plastic and Reconstructive Surgery; Aesthetic and Preventive Medicine at Heidelberg University Hospital; Heidelberg Germany
| | - Wolf Mueller
- University Hospital Leipzig, Department of Neuropathology; University of Leipzig; Leipzig Germany
| | - Jennifer Hartmann
- ETHIANUM-Clinic for Plastic and Reconstructive Surgery; Aesthetic and Preventive Medicine at Heidelberg University Hospital; Heidelberg Germany
| | - Yannick Diehm
- BG Trauma Centre Ludwigshafen; Clinic for Hand, Plastic and Reconstructive Surgery, Burn Centre, Hand and Plastic Surgery of the University of Heidelberg; Heidelberg Germany
| | - Ulrike Lass
- Clinical Cooperation Unit Neuropathology; German Cancer Research Center; Heidelberg Germany
| | - Eva Koellensperger
- ETHIANUM-Clinic for Plastic and Reconstructive Surgery; Aesthetic and Preventive Medicine at Heidelberg University Hospital; Heidelberg Germany
| | - Uwe Leimer
- ETHIANUM-Clinic for Plastic and Reconstructive Surgery; Aesthetic and Preventive Medicine at Heidelberg University Hospital; Heidelberg Germany
| | - Günter Germann
- ETHIANUM-Clinic for Plastic and Reconstructive Surgery; Aesthetic and Preventive Medicine at Heidelberg University Hospital; Heidelberg Germany
| | - Sebastian Fischer
- BG Trauma Centre Ludwigshafen; Clinic for Hand, Plastic and Reconstructive Surgery, Burn Centre, Hand and Plastic Surgery of the University of Heidelberg; Heidelberg Germany
| |
Collapse
|
5
|
Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 49:541-548. [PMID: 25686982 DOI: 10.1016/j.msec.2015.01.051] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Revised: 12/10/2014] [Accepted: 01/14/2015] [Indexed: 02/05/2023]
Abstract
Engineering of small diameter (<6mm) vascular grafts (SDVGs) for clinical use remains a significant challenge. Here, elastomeric polyester urethane (PEU)-based hollow fiber membranes (HFMs) are presented as an SDVG candidate to target the limitations of current technologies and improve tissue engineering designs. HFMs are fabricated by a simple phase inversion method. HFM dimensions are tailored through adjustments to fabrication parameters. The walls of HFMs are highly porous. The HFMs are very elastic, with moduli ranging from 1-4MPa, strengths from 1-5MPa, and max strains from 300-500%. Permeability of the HFMs varies from 0.5-3.5×10(-6)cm/s, while burst pressure varies from 25 to 35psi. The suture retention forces of HFMs are in the range of 0.8 to 1.2N. These properties match those of blood vessels. A slow degradation profile is observed for all HFMs, with 71 to 78% of the original mass remaining after 8weeks, providing a suitable profile for potential cellular incorporation and tissue replacement. Both human endothelial cells and human mesenchymal stem cells proliferate well in the presence of HFMs up to 7days. These results demonstrate a promising customizable PEU HFMs for small diameter vascular repair and tissue engineering applications.
Collapse
|
6
|
Mercado-Pagán ÁE, Ker DFE, Yang Y. Hemocompatibility evaluation of small elastomeric hollow fiber membranes as vascular substitutes. J Biomater Appl 2014; 29:557-65. [PMID: 24913612 DOI: 10.1177/0885328214537541] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
One of the main challenges for clinical implementation of small diameter vascular grafts (SDVGs) is their limited hemocompatibility. Important design specifications for such grafts include features that minimize the long-term risks of restenosis, fouling, and thrombus formation. In our lab, we have developed elastomeric hollow fiber membranes (HFMs), using a phase inversion method, as candidates for SDVGs. Here, we present our results for in vitro hemocompatibility testing of our HFM under flow and static conditions. Our results showed that the polymer-based HFMs do not damage the integrity of human red blood cells (RBCs) as shown by their low hemolytic extent (less than 2%). When analyzed for blood cell lysis using lactate dehydrogenase (LDH) activity as an indicator, no significant differences were observed between blood exposed to our HFMs and uncoagulated blood. Analysis of protein adsorption showed a low concentration of proteins deposited on the surfaces of HFM after 24 h. Platelet adhesion profiles using human platelet-rich plasma (PRP) showed that a low level of platelets adhered to the HFMs after 24 h, indicating minimal thrombotic potential. Under the majority of conditions, no significant differences were observed between medical-grade polymers and our HFMs. Eventual optimization of hemocompatible elastomeric HFM vessel grafts could lead to improved tissue vascularization as well as vascularized, tissue-engineered scaffolds for organ repair.
Collapse
Affiliation(s)
| | - Dai Fei Elmer Ker
- Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA
| | - Yunzhi Yang
- Department of Orthopaedic Surgery, Stanford University, Stanford, CA, USA Department of Materials Science and Engineering, Stanford University, Stanford, CA, USA
| |
Collapse
|
7
|
Owens CM, Marga F, Forgacs G, Heesch CM. Biofabrication and testing of a fully cellular nerve graft. Biofabrication 2013; 5:045007. [PMID: 24192236 DOI: 10.1088/1758-5082/5/4/045007] [Citation(s) in RCA: 119] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Rupture of a nerve is a debilitating injury with devastating consequences for the individual's quality of life. The gold standard of repair is the use of an autologous graft to bridge the severed nerve ends. Such repair however involves risks due to secondary surgery at the donor site and may result in morbidity and infection. Thus the clinical approach to repair often involves non-cellular solutions, grafts composed of synthetic or natural materials. Here we report on a novel approach to biofabricate fully biological grafts composed exclusively of cells and cell secreted material. To reproducibly and reliably build such grafts of composite geometry we use bioprinting. We test our grafts in a rat sciatic nerve injury model for both motor and sensory function. In particular we compare the regenerative capacity of the biofabricated grafts with that of autologous grafts and grafts made of hollow collagen tubes by measuring the compound action potential (for motor function) and the change in mean arterial blood pressure as consequence of electrically eliciting the somatic pressor reflex. Our results provide evidence that bioprinting is a promising approach to nerve graft fabrication and as a consequence to nerve regeneration.
Collapse
Affiliation(s)
- Christopher M Owens
- Department of Physics and Astronomy, University of Missouri, Columbia, MO 65211, USA
| | | | | | | |
Collapse
|
8
|
Donzelli R, Maiuri F, Piscopo GA, de Notaris M, Colella A, Divitiis E. Role of extracellular matrix components in facial nerve regeneration: an experimental study. Neurol Res 2013; 28:794-801. [PMID: 17288733 DOI: 10.1179/016164106x110427] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
OBJECTIVE The aim of this study is to evaluate the role of extracellular matrix components in nerve regeneration. Matrigel, a complex of extracellular matrix components such as laminin (the most abundant) heparan sulphate proteoglycans (HSPG), type IV collagen and fibronectin, was used. METHODS Forty male rabbits, which had undergone section of the right facial nerve, were later treated by reinnervation through an artificial graft of expanded polytetrafluoroethylene (ePTFE). In 20 animals the tubes of ePTFE were filled with Matrigel; in 20 control animals the tubes were filled with saline solution. RESULTS The Matrigel group showed a better axonal organization and a significantly higher number of regenerated axons in the early phases (at days 15 and 30 respectively) than the control group, whereas the difference of the axons number at day 60 was less significant; besides, the axon diameter and the myelin thickness were not significantly improved by Matrigel. DISCUSSION Our data suggest that Matrigel is an important factor in promoting and enhancing the early phases of the regeneration after nerve injuries. Tree neurite promoting agents, such as laminin, fibronectin and collagen, allow a more systematic and agonized regeneration. Extracellular matrix components may represent a direction guidance for axonal pathway.
Collapse
Affiliation(s)
- Renato Donzelli
- Department of Neurosurgery, University 'Federico II' School of Medicine, Naples, Italy.
| | | | | | | | | | | |
Collapse
|
9
|
Geuna S, Gnavi S, Perroteau I, Tos P, Battiston B. Tissue Engineering and Peripheral Nerve Reconstruction. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2013; 108:35-57. [DOI: 10.1016/b978-0-12-410499-0.00002-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
10
|
Rai R, Tallawi M, Grigore A, Boccaccini AR. Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review. Prog Polym Sci 2012. [DOI: 10.1016/j.progpolymsci.2012.02.001] [Citation(s) in RCA: 334] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
11
|
CHEN PEIRU, KANG PEILEUN, SU WENYU, LIN FENGHUEI, CHEN MINGHONG. THE EVALUATION OF THERMAL PROPERTIES AND IN VITRO TEST OF CARBODIIMIDE OR GLUTARALDEHYDE CROSS-LINKED GELATIN FOR PC 12 CELLS CULTURE. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS 2012. [DOI: 10.4015/s1016237205000160] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The thermal and degradable properties of carbodiimide (EDC) or glutaraldehyde (GTA) cross-linked gelatin membranes have been investigated in order to evaluate the effects of different concentrations of two kinds of cross-linking reagent on the stability of membranes. In the thermogram recorded from a gelatin membrane cross-linked with EDC solution, the endothermic peak of 0.8% EDC cross-linking gelatin was centered at about 61°C that was higher than other samples treated with EDC solutions. Denaturation temperature (Td) of gelatin samples increased on increasing EDC concentration (0.2% to 0.8%), in agreement with the simultaneous increased of the extent of cross-linking. But increasing GTA concentration from 0.05% to 0.6%, the Td values of gelatin samples were decreased from 66.2°C to 56.3°C . In addition, two endothermic peaks were observed in 0.4% and 0.6% GTA cross-linking groups because of the GTA concentration was too high to complete cross-linking reaction. Therefore, partial of gelatin membrane was cross-linked completely but others were not. In the thermogravimetric analysis, the proportion of cracking endothermic peak of 0.6% GTA cross-linking gelatin (g15G0.6) was higher than the peak of 0.6% EDC cross-linking gelatin (g15C0.6). Therefore, g15G0.6 cracked to smaller molecules has to absorb more calorific capacity than g15C0.6. The increase in the strength of covalent binding on increasing the proportion of endothermic peak was evident. The results of degradable rate were in agreement with the lower concentration of cross-linked reagent the faster degraded rate of gelatin membrane. The MTT assay showed that 15% gelatin cross-linked by 0.8% EDC has the least cytotoxicity, and cell activity of this group was similar to control group (blank dish). As the concentration of GTA in gelatin membranes was down to 0.05% or 0.1% the cell viability was returned to approach the value of control group.
Collapse
Affiliation(s)
- PEI-RU CHEN
- Institute of Biomedical Engineering, College of Medicine, College of Engineering, National Taiwan University, Taipei, Taiwan
| | - PEI-LEUN KANG
- Cardiovascular Division, Department of surgery, Kaoshiung Veterans General Hospital, Kaoshiung, Taiwan
| | - WEN-YU SU
- Institute of Biomedical Engineering, College of Medicine, College of Engineering, National Taiwan University, Taipei, Taiwan
| | - FENG-HUEI LIN
- Institute of Biomedical Engineering, College of Medicine, College of Engineering, National Taiwan University, Taipei, Taiwan
| | - MING-HONG CHEN
- Institute of Biomedical Engineering, College of Medicine, College of Engineering, National Taiwan University, Taipei, Taiwan
- Division of Neurosurgery, Department of surgery, Cathay General Hospital, Taiwan
| |
Collapse
|
12
|
HUANG YICHENG, HUANG YIYOU. TISSUE ENGINEERING FOR NERVE REPAIR. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS 2012. [DOI: 10.4015/s101623720600018x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Nerve regeneration is a complex biological phenomenon. Once the nervous system is impaired, its recovery is difficult and malfunctions in other parts of the body may occur because mature neurons don't undergo cell division. To increase the prospects of axonal regeneration and functional recovery, researches have focused on designing “nerve guidance channels” or “nerve conduits”. For developing tissue engineered nerve conduits, four components come to mind, including a scaffold for axonal proliferation, supporting cells such as Schwann cells, growth factors, and extracelluar matrix. This article reviews the nervous system physiology, the factors that are critical for nerve repair, and the advanced technologies that are explored to fabricate nerve conduits. Furthermore, we also introduce a new method we developed to create longitudinally oriented channels within biodegradable polymers, Chitosan and PLGA, using a combined lyophilizing and wire-heating process. This innovative method using Ni-Cr wires as mandrels to create nerve guidance channels. The process is easy, straightforward, highly reproducible, and could easily be tailored to other polymer and solvent systems. These scaffolds could be useful for guided regeneration after transection injury in either the peripheral nerve or spinal cord.
Collapse
Affiliation(s)
- YI-CHENG HUANG
- Institute of Biomedical Engineering, College of Medicine and Engineering, National Taiwan University, Taipei, Taiwan
| | - YI-YOU HUANG
- Institute of Biomedical Engineering, College of Medicine and Engineering, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
13
|
Lin YC, Marra KG. Injectable systems and implantable conduits for peripheral nerve repair. Biomed Mater 2012; 7:024102. [DOI: 10.1088/1748-6041/7/2/024102] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
14
|
Sun M, Kingham PJ, Reid AJ, Armstrong SJ, Terenghi G, Downes S. In vitro and in vivo testing of novel ultrathin PCL and PCL/PLA blend films as peripheral nerve conduit. J Biomed Mater Res A 2010; 93:1470-81. [PMID: 19967758 DOI: 10.1002/jbm.a.32681] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In an attempt to obviate the drawbacks of nerve autograft, ultrathin microporous biodegradable PCL and PCL/PLA films were tested for their compatibility with motor neuron-like NG108-15 cells and primary Schwann cells. Data obtained from MTS colorimetric and DNA fluorimetric assays showed that both cell lines readily attached and proliferated on these materials. Images taken using scanning electron microscope and fluorescence microscope confirmed these observations. Enhanced cell-surface interaction was achieved by pretreating the films in NaOH solution. Importantly, NG108-15 cells could be induced into differentiated phenotype with long, un-branched neurites growing across the surface of the materials. The bipolar spindle-shaped phenotype of Schwann cells was also retained on these scaffolds. Positive immunochemical staining using antibodies against neurofilament for NG108-15 cells and S100 for Schwann cells indicated the expression of these marker proteins. In a small-scaled pilot testing, the performance of PCL conduits in bridging up a 10 mm gap in rat sciatic nerve model was assessed. Immunohistochemical staining showed that regenerated nerve tissue and penetrated Schwann cells have the potential to span the whole length of the conduit in 2 weeks.
Collapse
Affiliation(s)
- M Sun
- Materials Science Centre, Department of Engineering and Physical Sciences, The University of Manchester, Grosvenor Street, Manchester M1 7HS, United Kingdom
| | | | | | | | | | | |
Collapse
|
15
|
Sinis N, Kraus A, Tselis N, Haerle M, Werdin F, Schaller HE. Functional recovery after implantation of artificial nerve grafts in the rat- a systematic review. J Brachial Plex Peripher Nerve Inj 2009; 4:19. [PMID: 19852862 PMCID: PMC2770034 DOI: 10.1186/1749-7221-4-19] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2009] [Accepted: 10/25/2009] [Indexed: 01/26/2023] Open
Abstract
Purpose The aim of this study was to compare functional data of different nerve-gap bridging materials evaluated in rat experiments by means of a systematic review. Materials and methods A systematic review was conducted, searching MEDLINE, HTS and CENTRAL to identify all trials evaluating functional recovery of artificial nerve conduits in the rat model. Results There was a trend towards a favourable outcome of conduits coated with Schwann-cells compared to the plain synthetics. Histomorphometry, electrophysiology and muscle-weight correlated poorly with functional outcome. Conclusion Schwann-cell coated conduits showed promising results concerning functional recovery. Further standardization in outcome reporting is encouraged.
Collapse
Affiliation(s)
- Nektarios Sinis
- Clinic for Hand, Plastic, Reconstructive and Burn Surgery, BG Trauma Center, Eberhard-Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany
| | - Armin Kraus
- Clinic for Hand, Plastic, Reconstructive and Burn Surgery, BG Trauma Center, Eberhard-Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany
| | - Nikolaos Tselis
- Dept of Radiotherapy, Hospital of Offenbach, Starkenburgring 66, D-63069 Offenbach, Germany
| | - Max Haerle
- Dept of Hand and Plastic Surgery, Orthopaedic Hospital Markgroeningen, Kurt-Lindemann-Weg 10 D-71706 Markgroeningen, Germany
| | - Frank Werdin
- Clinic for Hand, Plastic, Reconstructive and Burn Surgery, BG Trauma Center, Eberhard-Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany
| | - Hans-Eberhard Schaller
- Clinic for Hand, Plastic, Reconstructive and Burn Surgery, BG Trauma Center, Eberhard-Karls University, Schnarrenbergstrasse 95, D-72076 Tuebingen, Germany
| |
Collapse
|
16
|
Jiang X, Lim SH, Mao HQ, Chew SY. Current applications and future perspectives of artificial nerve conduits. Exp Neurol 2009; 223:86-101. [PMID: 19769967 DOI: 10.1016/j.expneurol.2009.09.009] [Citation(s) in RCA: 268] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2009] [Revised: 09/09/2009] [Accepted: 09/11/2009] [Indexed: 12/27/2022]
Abstract
Artificial nerve guide conduits have the advantage over autografts in terms of their availability and ease of fabrication. However, clinical outcomes associated with the use of artificial nerve conduits are often inferior to that of autografts, particularly over long lesion gaps. There have been significant advances in the designs of artificial nerve conduits over the years. In terms of materials selection and design, a wide variety of new synthetic polymers and biopolymers have been evaluated. The inclusion of nerve conduit lumen fillers has also been demonstrated as essential to enable nerve regeneration across large defect gaps. These lumen filler designs have involved the integration of physical cues for contact guidance and biochemical signals to control cellular function and differentiation. Novel conduit architectural designs using porous and fibrous substrates have also been developed. This review highlights the recent advances in synthetic nerve guide designs for peripheral nerve regeneration, and the in vivo applicability and future prospects of these nerve guide conduits.
Collapse
Affiliation(s)
- Xu Jiang
- School of Chemical & Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Block N1.2-B2-20, Singapore 637459, Singapore
| | | | | | | |
Collapse
|
17
|
Xu H, Yan Y, Wan T, Li S. Degradation properties of the electrostatic assembly PDLLA/CS/CHS nerve conduit. Biomed Mater 2009; 4:045006. [DOI: 10.1088/1748-6041/4/4/045006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Sun M, Downes S. Physicochemical characterisation of novel ultra-thin biodegradable scaffolds for peripheral nerve repair. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2009; 20:1181-1192. [PMID: 19132511 DOI: 10.1007/s10856-008-3671-3] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2008] [Accepted: 12/15/2008] [Indexed: 05/27/2023]
Abstract
In this study, the physicochemical properties of microporous poly (epsilon-caprolactone) (PCL) films and a composite material made of PCL and polylactic acid (PLA) blend were tested. Fabricated by solvent casting using dichloromethane, these ultra-thin films (60 +/- 5 microm in thickness) have a novel double-sided surface topography, i.e. a porous surface with pores 1-10 microm in diameter and a relatively smooth surface with nano-scaled texture. Porous surfaces were found to be associated with increased protein adsorption and the treatment of these polyester scaffolds with NaOH rendered them more hydrophilic. Differential Scanning Calorimetry (DSC) showed that the incorporation of PLA reduced the crystallinity of the original homopolymer. Chemical changes were investigated by means of Fourier Transform Infrared Spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). Average surface roughness (Ra), hydrophilicity/hydrophobicity and mechanical properties of these materials were also assessed for the suitability of these materials as nerve conduits.
Collapse
Affiliation(s)
- Mingzhu Sun
- Department of Engineering and Physical Sciences, Materials Science Centre, The University of Manchester, Manchester, UK
| | | |
Collapse
|
19
|
Cui T, Yan Y, Zhang R, Liu L, Xu W, Wang X. Rapid Prototyping of a Double-Layer Polyurethane–Collagen Conduit for Peripheral Nerve Regeneration. Tissue Eng Part C Methods 2009; 15:1-9. [DOI: 10.1089/ten.tec.2008.0354] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
20
|
Chang CJ. The Effect of Pulse-Released Nerve Growth Factor from Genipin-Crosslinked Gelatin in Schwann Cell–Seeded Polycaprolactone Conduits on Large-Gap Peripheral Nerve Regeneration. Tissue Eng Part A 2009; 15:547-57. [DOI: 10.1089/ten.tea.2007.0342] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
21
|
Battiston B, Raimondo S, Tos P, Gaidano V, Audisio C, Scevola A, Perroteau I, Geuna S. Chapter 11 Tissue Engineering of Peripheral Nerves. INTERNATIONAL REVIEW OF NEUROBIOLOGY 2009; 87:227-49. [DOI: 10.1016/s0074-7742(09)87011-6] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
22
|
Piskin A, Kaplan S, Aktaş A, Ayyildiz M, Raimondo S, Aliç T, Bozkurt HH, Geuna S. Platelet gel does not improve peripheral nerve regeneration: An electrophysiological, stereological, and electron microscopic study. Microsurgery 2008; 29:144-53. [DOI: 10.1002/micr.20599] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
23
|
|
24
|
Vein Grafts Used as Nerve Conduits for Obstetrical Brachial Plexus Palsy Reconstruction. Plast Reconstr Surg 2007; 120:1930-1941. [DOI: 10.1097/01.prs.0000287391.12943.00] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
25
|
Vleggeert-Lankamp CLAM. The role of evaluation methods in the assessment of peripheral nerve regeneration through synthetic conduits: a systematic review. J Neurosurg 2007; 107:1168-89. [DOI: 10.3171/jns-07/12/1168] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Object
A number of evaluation methods that are currently used to compare peripheral nerve regeneration with alternative repair methods and to judge the outcome of a new paradigm were hypothesized to lack resolving power. This would too often lead to the conclusion that the outcome of a new paradigm could not be discerned from the outcome of the current gold standard, the autograft. As a consequence, the new paradigm would incorrectly be judged as successful.
Methods
An overview of the methods that were used to evaluate peripheral nerve regeneration after grafting of the rat sciatic nerve was prepared. All articles that were published between January 1975 and December 2004 and concerned grafting of the rat sciatic nerve (minimum graft length 5 mm) and in which the experimental method was compared with an untreated or another grafted nerve were included. The author scored the presence of statistically significant differences between paradigms.
Results
Evaluation of nerve fiber count, nerve fiber density, N-ratio, nerve histological success ratio, compound muscle action potential, muscle weight, and muscle tetanic force are methods that were demonstrated to have resolving power.
Conclusions
A number of evaluation methods are not suitable to demonstrate a significant difference between experimental paradigms in peripheral nerve regeneration. It is preferable to apply a combination of evaluation methods with resolving power to evaluate nerve regeneration properly.
Collapse
|
26
|
Chang CJ, Hsu SH, Yen HJ, Chang H, Hsu SK. Effects of unidirectional permeability in asymmetric poly(DL-lactic acid-co-glycolic acid) conduits on peripheral nerve regeneration: Anin vitro andin vivo study. J Biomed Mater Res B Appl Biomater 2007; 83:206-15. [PMID: 17405166 DOI: 10.1002/jbm.b.30785] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The high outflow permeability of the nerve conduit used to emit the drained waste generated from the traumatized host nerve stump is critical in peripheral nerve regeneration. Our earlier studies have established that asymmetric conduits fulfill the basic requirements for use as nerve guide conduits. In this study, the inflow characteristics of optimal nerve conduits were further examined using in vivo and in vitro trials. Various asymmetric poly(DL-lactic acid-co-glycolic acid) (PLGA) conduits were controlled by modifying precipitation baths using 0, 20, and 95% isopropyl alcohol, with high-porosity (permeability), medium-porosity (high outflow and low inflow), and low-porosity (permeability), respectively. In the in vitro trial, the Schwann cells and fibroblasts were seeded on either side of the asymmetric PLGA films in a newly designed coculture system that simulated the repaired nerve conduit environment. The results of the directional permeable films indicated the statistically significant proliferation of Schwann cells and the inhibition of the division of fibroblasts in lactate dehydrogenase release and inhibition of 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl-tetrazolium bromide (MTT) reduction, compared with the other films. In the in vivo trial, the PLGA conduits seeded with Schwann cells were implanted into 10 mm right sciatic nerve defects in rats. After 6 weeks, implanted conduits were harvested. Histological examination verified that directional permeable conduits had markedly more A-type and B-type myelin fibers in the midconduit and distal nerve. In this work, the directional transport characteristics were established as an extremely important factor to the design and development of optimal nerve guide conduits in peripheral nerve regeneration.
Collapse
Affiliation(s)
- Chen-Jung Chang
- Department of Radiological Technology, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | | | | | | | | |
Collapse
|
27
|
Vleggeert-Lankamp CLAM, de Ruiter GCW, Wolfs JFC, Pêgo AP, van den Berg RJ, Feirabend HKP, Malessy MJA, Lakke EAJF. Pores in synthetic nerve conduits are beneficial to regeneration. J Biomed Mater Res A 2006; 80:965-82. [PMID: 17106899 DOI: 10.1002/jbm.a.30941] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Current opinion holds that pores in synthetic nerve guides facilitate nerve regeneration. Solid factual support for this opinion, however, is absent; most of the relevant studies assessed only morphological parameters and results have been contradictory. To evaluate the effect of pores, the rat sciatic nerve was either autografted or grafted with nonporous, macroporous (10-230 mum), and microporous (1-10 microm) biodegradable epsilon-caprolactone grafts. Twelve weeks later, the grafted nerves were resected, and the electrophysiological properties were determined in vitro. Subsequently midgraft-level sections were inspected, and peroneal nerve sections were evaluated morphometrically. Finally, the gastrocnemic and tibial muscle morphometrical properties were quantified. The microporous nerve graft performed much better than the nonporous and macroporous grafts with respect to most parameters: it was bridged by a free floating bundle that contained myelinated nerve fibers, there were more nerve fibers present distal to the graft, the electrophysiological response rate was higher, and the decrease in muscle cross-sectional area was markedly smaller. Hence, the present study demonstrates the beneficial effect of synthetic nerve guide pores on nerve regeneration, although with the caveat that not pores per se, but only small (1-10 microm) pores were effective.
Collapse
Affiliation(s)
- C L A M Vleggeert-Lankamp
- Neuroregulation Group, Department of Neurosurgery, Leiden University Medical Centre (LUMC), P.O. Box 9600, NL-2300 RC Leiden, the Netherlands.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Nerve regeneration is a complex biological phenomenon. Once the nervous system is impaired, its recovery is difficult and malfunctions in other parts of the body may occur because mature neurons do not undergo cell division. To increase the prospects of axonal regeneration and functional recovery, researches have focused on designing "nerve guidance channels" or "nerve conduits." When developing ideal tissue-engineered nerve conduits, several components come to mind. They include a biodegradable and porous channel wall, the ability to deliver bioactive growth factors, incorporation of support cells, an internal oriented matrix to support cell migration, intraluminal channels to mimic the structure of nerve fascicles, and electrical activities. This article reviews the factors that are critical for nerve repair, and the advanced technologies that are explored to fabricate nerve conduits. To more accurately mimic natural repair in the body, recent studies have focused on the use of various advanced approaches to create ideal nerve conduits that combine multiple stimuli in an effort to better mimic the complex signals normally found in the body.
Collapse
Affiliation(s)
- Yi-Cheng Huang
- Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Taiwan.
| | | |
Collapse
|
29
|
Chang CJ, Hsu SH. The effect of high outflow permeability in asymmetric poly(dl-lactic acid-co-glycolic acid) conduits for peripheral nerve regeneration. Biomaterials 2006; 27:1035-42. [PMID: 16098582 DOI: 10.1016/j.biomaterials.2005.07.003] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2005] [Accepted: 07/02/2005] [Indexed: 10/25/2022]
Abstract
This study attempted to accelerate the peripheral nerve regeneration, using the high outflow rate of asymmetric poly(dl-lactic acid-co-glycolic acid) (PLGA) nerve conduits. Asymmetric PLGA nerve conduits of monomer ratio 85/15 were prepared by immersion-precipitation method to serve as possible materials. In this study, mandrels were immersed into a 20% (wt/wt) of PLGA/1,4-dioxane solution and precipitated in a non-solvent bath followed by freeze-drying. Different concentrations of isopropyl alcohol (95%, 40% and 20%) were used as precipitation baths where non-asymmetric (95%) and asymmetric (40% and 20%) conduits could easily form. The asymmetric nerve conduits that consisted of macrovoids on the outer layer, and interconnected micropores in the inner sublayer, possessed characters of larger outflow rate than inflow rate. The asymmetric conduits were implanted to 10mm right sciatic nerve defects in rats. Autografts, silicone and non-asymmetric PLGA conduits were performed as the control and the contrast groups. Implanted graft specimens of all groups were harvested for histological analysis at 4 and 6 weeks following surgery. The asymmetric PLGA conduits maintained a stable supporting structure and inhibited exogenous cells invasion during entire regeneration process. Asymmetric PLGA conduits were found to have statistically greater number of regenerated axons at the midconduit and distal nerve site of implanted grafts, as compared to the silicone and non-asymmetric groups at 4 and 6 weeks. Of interest was that the results of 4 weeks in asymmetric groups were better than the non-asymmetric groups at 6 weeks in number of axons. According to the results of permeability, the asymmetric structure in the conduit wall seemed to enhance the removal of the blockage of the waste drain from the inner inflamed wound in the early stage, which may have improved the efficacy of the peripheral nerve regeneration. The asymmetric structure could be adequately employed in the future as optimal nerve conduits in peripheral nerve regeneration.
Collapse
Affiliation(s)
- Chen-Jung Chang
- Department of Radiological Technology, Chung-Tai Institute of Health Science and Technology, Taichung, Taiwan
| | | |
Collapse
|
30
|
Chang CJ, Hsu SH, Lin FT, Chang H, Chang CS. Low-intensity-ultrasound-accelerated nerve regeneration using cell-seeded poly(D,L-lactic acid-co-glycolic acid) conduits: an in vivo and in vitro study. J Biomed Mater Res B Appl Biomater 2006; 75:99-107. [PMID: 16015644 DOI: 10.1002/jbm.b.30269] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This study investigated the effects of low intensity ultrasound on seeded Schwann cells within poly(DL-lactic acid-co-glycolic acid) (PLGA) conduits by in vitro and in vivo trials for peripheral nerve regeneration. The possible differences in the ultrasonic effects when using biodegradable and non-biodegradable materials as the conduits were also studied, using silicone rubber tubes as comparisons. In the in vitro study, seeded Schwann cells were cultured in serum deprivation culture medium that simulated the environment of mechanical trauma on injury nerve site. After 12, 24, and 48 h, only the PLGA conduit groups exposed to 0.05 W/cm(2), 3 min/treatment of ultrasound exhibited decreased LDH release and increased MTT values compared to the sham groups. Based on the results of the in vitro experiment in LDH and MTT testing, the silicone conduits with seeded Schwann cells group was ignored in the in vivo study. The PLGA nerve conduits seeded with Schwann cells (9 x 10(3) cells) were implanted to 15-mm right sciatic nerve defects in rats. Each conduit received 12 ultrasonic treatment sessions over 2 weeks after 1 day of rest. Ultrasound was applied as follows: frequency, 1MHz; intensity, 0.3 W/cm(2) (SATP); treatment, 5 min/day. Implanted graft specimens were harvested for histological analysis at 8 weeks following surgery. PLGA groups (with and without Schwann cells) treated with pulsed ultrasonic stimulation were found to have significantly greater number and area of regenerated axons at the mid-conduit of implanted grafts, as compared to the sham groups. Ultrasonic stimulation on silicone groups was found to induce a mass of fibrous tissues that covered the nerve conduits and retarded axon regeneration.
Collapse
Affiliation(s)
- Chen-Jung Chang
- Department of Radiological Technology, Chung-Tai Institute of Health Science and Technology, Taichung, Taiwan, Republic of China
| | | | | | | | | |
Collapse
|
31
|
Chen MH, Chen PR, Chen MH, Hsieh ST, Huang JS, Lin FH. Anin vivo study of tricalcium phosphate and glutaraldehyde crosslinking gelatin conduits in peripheral nerve repair. J Biomed Mater Res B Appl Biomater 2006; 77:89-97. [PMID: 16211569 DOI: 10.1002/jbm.b.30402] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In order to modulate the mechanical properties of gelatin, we previously developed a biodegradable composite composed by tricalcium phosphate and glutaraldehyde crosslinking gelatin (GTG) feasible for surgical manipulation. In this study, we evaluated the in vivo applications of GTG conduit for peripheral nerve repair. The effect of sciatic nerve reconstruction was compared between resorbable permeable GTG conduits and durable impermeable silicone tubes. Traditional methods of assessing nerve recovery following peripheral nerve repair including histomorphometric and electrophysiologic features were conducted in our study. In addition, autotomy score and sciatic function index (SFI) in walking tract analysis were used as additional parameters for assessing the return of nerve function. Twenty-four weeks after sciatic nerve repair, the GTG conduits were harvested. Microscopically, regeneration of nerves was observed in the cross-section at the mid portion of all implanted GTG conduits. The cross-sectional area of regenerated nerve of the GTG group was significant larger than that of the silicone group. In the compound muscle action potentials (CMAP), the mean recovery index of CMAP amplitude was 0.24 +/- 0.02 for the silicone group, 0.41 +/- 0.07 for the GTG group. The mean SFI increased with time in the GTG group during the evaluation period until 24 weeks. Walking tract analysis showed a higher SFI score in the GTG group at both 12 and 24 weeks. The difference reached a significant level at 24 weeks. Thus, the histomorphometric, electrophysiologic, and functional assessments demonstrate that GTG can be a candidate for peripheral nerve repair.
Collapse
Affiliation(s)
- Ming-Hong Chen
- Institute of Biomedical Engineering, National Taiwan University, No. 1, Sec. 1, Jen-Ai Road, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
32
|
Weyn B, van Remoortere M, Nuydens R, Meert T, van de Wouwer G. A multiparametric assay for quantitative nerve regeneration evaluation. J Microsc 2005; 219:95-101. [PMID: 16159345 DOI: 10.1111/j.1365-2818.2005.01495.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
We introduce an assay for the semi-automated quantification of nerve regeneration by image analysis. Digital images of histological sections of regenerated nerves are recorded using an automated inverted microscope and merged into high-resolution mosaic images representing the entire nerve. These are analysed by a dedicated image-processing package that computes nerve-specific features (e.g. nerve area, fibre count, myelinated area) and fibre-specific features (area, perimeter, myelin sheet thickness). The assay's performance and correlation of the automatically computed data with visually obtained data are determined on a set of 140 semithin sections from the distal part of a rat tibial nerve from four different experimental treatment groups (control, sham, sutured, cut) taken at seven different time points after surgery. Results show a high correlation between the manually and automatically derived data, and a high discriminative power towards treatment. Extra value is added by the large feature set. In conclusion, the assay is fast and offers data that currently can be obtained only by a combination of laborious and time-consuming tests.
Collapse
Affiliation(s)
- B Weyn
- Visielab, Department of Physics, University of Antwerp, Belgium.
| | | | | | | | | |
Collapse
|
33
|
Battiston B, Geuna S, Ferrero M, Tos P. Nerve repair by means of tubulization: literature review and personal clinical experience comparing biological and synthetic conduits for sensory nerve repair. Microsurgery 2005; 25:258-67. [PMID: 15934044 DOI: 10.1002/micr.20127] [Citation(s) in RCA: 240] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Nerve repair is usually accomplished by direct suture when the two stumps can be approximated without tension. In the presence of a nerve defect, the placement of an autologous nerve graft is the current gold standard for nerve restoration. However, over the last 20 years, an increasing number of research articles reported on the use of non-nervous tubes (tubulization) for repairing nerve defects. The clinical employment of tubes (both biological and synthetic) as an alternative to autogenous nerve grafts is mainly justified by the limited availability of donor tissue for nerve autografts and the related morbidity. In addition, tubulization was proposed as an alternative to direct nerve sutures in order to create optimal conditions for nerve regeneration over the short empty space intentionally left between two nerve stumps. This paper outlines recent important advances in this field. Different tubulization techniques proposed so far are described, focusing in particular on studies that reported on the employment of tubes with patients. Our personal clinical experience on tubulization repair of sensory nerve lesions (digital nerves), using both biological and synthetic tubes, is presented, and the clinical results are compared. In our case series, both types of tubes led to good clinical results. Finally, we speculate about the prospects in the clinical application of tubulization for peripheral nerve repair.
Collapse
Affiliation(s)
- Bruno Battiston
- UOD Reconstructive Microsurgery, Department of Orthopedics, C.T.O. Hospital, Turin, Italy.
| | | | | | | |
Collapse
|
34
|
Bertleff MJOE, Meek MF, Nicolai JPA. A prospective clinical evaluation of biodegradable neurolac nerve guides for sensory nerve repair in the hand. J Hand Surg Am 2005; 30:513-8. [PMID: 15925161 DOI: 10.1016/j.jhsa.2004.12.009] [Citation(s) in RCA: 161] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2004] [Revised: 12/17/2004] [Accepted: 12/17/2004] [Indexed: 02/02/2023]
Abstract
PURPOSE Our purpose was to study the recovery of sensory nerve function after treatment of traumatic peripheral nerve lesions with a biodegradable poly(DL-lactide-epsilon-caprolactone) Neurolac nerve guide (Polyganics B.V., Groningen, the Netherlands) versus the current standard reconstruction techniques. METHODS Thirty patients with 34 nerve lesions were included in this randomized, multicenter trial. RESULTS Both groups were comparable considering their demographics. After a small learning curve the nerve guide could be implanted easily. There were more complications in the experimental group but none of them was directly device related. Recovery of sensibility in the nerve guide group was at least as good as in the control group. CONCLUSIONS These results indicate that the Neurolac nerve guide is suitable for the repair of transected peripheral nerves in the hand.
Collapse
|
35
|
IJkema-Paassen J, Jansen K, Gramsbergen A, Meek MF. Transection of peripheral nerves, bridging strategies and effect evaluation. Biomaterials 2004; 25:1583-92. [PMID: 14697860 DOI: 10.1016/s0142-9612(03)00504-0] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Disruption of peripheral nerves due to trauma is a frequently occurring clinical problem. Gaps in the nerve are bridged by guiding the regenerating nerves along autologous grafts or artificial guides. This review gives an overview on the different methods of nerve repair techniques. Conventional suturing techniques are discussed as well as the use of e.g. biological, synthetic, non-degradable or degradable nerve guides. Functional assessment showed that repair of a gap with a bio-degradable guide is superior to that with autologous grafts. But still, long lasting changes were observed in the Sciatic Function Index (SFI), abnormal walking patterns, disturbed Electro Myo Graphic (EMG) patterns, next to shifts in the histochemical properties of the muscles and longlasting abnormalities in neuromuscular contacts. These phenomena are explained by an at-random reinnervation. When transecting the nerve at young ages, this did not lead to enhanced recovery. Rearing rats operated at adult age in an enriched environment, also had no beneficial effect. Future research should aim at developing longer guides, possibly lined with Schwann cells, or additives, improving specific reinnervation of the former target areas.
Collapse
Affiliation(s)
- J IJkema-Paassen
- Department of Medical Physiology, University of Groningen, Ant. Deusinglaan 1, bldg 3215, Groningen 9713 AV, The Netherlands.
| | | | | | | |
Collapse
|
36
|
Bryan DJ, Tang JB, Doherty SA, Hile DD, Trantolo DJ, Wise DL, Summerhayes IC. Enhanced peripheral nerve regeneration through a poled bioresorbable poly(lactic-co-glycolic acid) guidance channel. J Neural Eng 2004; 1:91-8. [PMID: 15876627 DOI: 10.1088/1741-2560/1/2/004] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
In this study we investigated the effects of materials prepared with electrical poling on neurite outgrowth in vitro and nerve regeneration in vivo. Neuro-2a cells were seeded on poled and unpoled poly(lactic-co-glycolic) (PLGA) films and observed at time periods 24, 48 and 72 h post-seeding. The percentage of cells with neurites and the neurites per cell were quantified using light microscopy. At 48 and 72 h post-seeding, both the number of cells with neurites and the neurites per cell were significantly increased on the poled films compared to those on unpoled films. An established rat sciatic nerve model was used for in vivo studies to assess the effects of PLGA guides, poled for two different periods, on peripheral nerve regeneration. Guides were inserted in rats to bridge a 1.0 cm gap created in the right sciatic nerve. After four weeks, nerves regenerated through poled guides displayed a significant increase in conduction velocity and significantly increased numbers of axons across the guides, as compared to nerves regenerating through an unpoled guidance channel. Electrical poling was shown to promote neurite growth, axon regeneration and the conduction rate of the repaired nerve. We concluded that guides prepared with electrical poling enhance peripheral nerve regeneration.
Collapse
Affiliation(s)
- David J Bryan
- Tissue Engineering Laboratory, Robert E Wise MD Research and Education Institute, Lahey Clinic Medical Center, 31 Mall Road, Burlington, MA 01805, USA.
| | | | | | | | | | | | | |
Collapse
|
37
|
Gunn JW, Turner SD, Mann BK. Adhesive and mechanical properties of hydrogels influence neurite extension. ACTA ACUST UNITED AC 2004; 72:91-7. [PMID: 15536643 DOI: 10.1002/jbm.a.30203] [Citation(s) in RCA: 161] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Photopolymerizable polyethylene glycol (PEG) hydrogels conjugated with bioactive ligands were examined for their use as scaffolds in peripheral nerve regeneration applications. The bioactivity and mechanical properties of PEG hydrogels can be tailored through the integration of bioactive factors (adhesion ligands, proteolytic sites, growth factors) and the alteration of PEG concentrations, respectively. For peripheral nerve regeneration, it will be important to determine the type and concentration of the bioactive molecules required to improve neurite extension. In this study, cell adhesion ligands (RGDS, IKVAV, and YIGSR) were covalently attached to PEG hydrogels. Both the type and concentration of cell adhesion ligand used affected neurite extension. Extension from PC12 cells was greater on hydrogels with RGDS incorporated than IKVAV, and the optimal concentration for each ligand was different. Cells adhered to but did not extend neurites on hydrogels with YIGSR. Cells did not adhere to hydrogels containing RGES. Furthermore, different combinations of these ligands affected neurite extension to different degrees. The mechanical properties of the hydrogels also significantly affected neurite extension. PC12 cells grown on more flexible hydrogels exhibited the greatest degree of neurite extension. PEG hydrogels have thus been developed with varying biochemical and mechanical properties that may enhance nerve regeneration.
Collapse
Affiliation(s)
- Jonathan W Gunn
- Keck Graduate Institute, 535 Watson Drive, Claremont, California 91711, USA
| | | | | |
Collapse
|
38
|
|
39
|
Chafik D, Bear D, Bui P, Patel A, Jones NF, Kim BT, Hung CT, Gupta R. Optimization of Schwann cell adhesion in response to shear stress in an in vitro model for peripheral nerve tissue engineering. TISSUE ENGINEERING 2003; 9:233-41. [PMID: 12740086 DOI: 10.1089/107632703764664701] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The design of nerve guidance channels (NGCs) is evolving to produce a favorable environment for neural regeneration. We created an in vitro model to evaluate the interactions between three centrally important components of this altered host environment: (1). Schwann cells, (2). substrate, and (3). sustained mechanical stimulus in the form of shear stress with laminar fluid flow. Preconfluent Schwann cells were plated on slides coated either with laminin, poly-D-lysine, type IV collagen, or fibronectin. These slides were placed into custom-designed, parallel-plate, flow chambers and were administered laminar fluid flow at a rate of 15 mL/min for 2 h. Schwann cell adhesion assays demonstrated that laminin (mean, 86.1%; SEM, 4.47%) and fibronectin (mean, 81.7%; SEM, 3.24%) were statistically superior to collagen type IV (mean, 57.7%; SEM, 3.96%) and poly-D-lysine (mean, 58.0%; SEM, 4.97%) (p < 0.001). Fibronectin (mean, 12.20%; SEM, 0.374%) induced statistically greater Schwann cell proliferation than did laminin (mean, 8.14%; SEM, 0.682%) (p < 0.001). Therefore, we recommend that fibronectin should be used as an important component of NGCs with further in vivo studies. As mechanical stress is an integral part of the host environment, our study is the first to incorporate this factor into an in vitro model for peripheral nerve tissue engineering.
Collapse
Affiliation(s)
- Dara Chafik
- Department of Orthopedic Surgery, University of California, Irvine, Irvine, California 92657, USA
| | | | | | | | | | | | | | | |
Collapse
|
40
|
|
41
|
Wang S, Wan AC, Xu X, Gao S, Mao HQ, Leong KW, Yu H. A new nerve guide conduit material composed of a biodegradable poly(phosphoester). Biomaterials 2001; 22:1157-69. [PMID: 11352095 DOI: 10.1016/s0142-9612(00)00356-2] [Citation(s) in RCA: 143] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
There is a resurgence of interest in the development of degradable and biocompatible polymers for fabrication of nerve guide conduits (NGCs) in recent years. Poly(phosphoester) (PPE) polymers are among the attractive candidates in this context, in view of their high biocompatibility, adjustable biodegradability, flexibility in coupling fragile biomolecules under physiological conditions and a wide variety of physicochemical properties. The feasibility of using a biodegradable PPE, P(BHET-EOP/TC), as a novel NGC material was investigated. Two types of conduits were fabricated by using two batches of P(BHET-EOP/TC) with different weight-average molecular weights (Mw) and polydispersity indexes (PI). The polymers as well as conduits were non-toxic to all six types of cells tested, including primary neurones and neuronally differentiated PC12 cells. After in situ implantation in the sciatic nerve of the rat, two types of conduits triggered a similar tissue response, inducing the formation of a thin tissue capsule composed of approximately eight layers of fibroblasts surrounding the conduits at 3 months. Biological performances of the conduits were examined in the rat sciatic nerve model with a 10 mm gap. Although tube fragmentation, even tube breakage, was observed within less than 5 days post-implantation, successful regeneration through the gap occurred in both types of conduits, with four out of 10 in the Type I conduits (Mw 14,900 and PI 2.57) and 11 out of 12 in the Type II conduits (Mw 18,900 and PI 1.72). The degradation of conduits was further evidenced by increased roughness on the tube surface in vivo under scanning electron microscope and a mass decrease in a time-dependent manner in vitro. The Mw of the polymers dropped 33 and 24% in the Type I and II conduits, respectively, in vitro within 3 months. Among their advantages over other biodegradable NGCs, the PPE conduits showed negligible swelling and no crystallisation after implantation. Thus, these PPE conduits can be effective aids for nerve regeneration with potential to be further developed into more sophisticated NGCs that have better control of the conduit micro-environment for improved nerve regeneration.
Collapse
Affiliation(s)
- S Wang
- Tissue Engineering Initiative, Institute of Materials Research & Engineering and National University of Singapore, Singapore.
| | | | | | | | | | | | | |
Collapse
|
42
|
Heijke GC, Klopper PJ, Van Doorn IB, Baljet B. Processed porcine collagen tubulization versus conventional suturing in peripheral nerve reconstruction: An experimental study in rabbits. Microsurgery 2001; 21:84-95. [PMID: 11372068 DOI: 10.1002/micr.1015] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In peripheral nerve reconstruction, various procedures are used. One of the procedures that received the most interest in the past decade is the tubulization technique for small nerve gaps. A disadvantage in the use of non-biodegradable tubes is that the material often has to be removed owing to its mechanical properties. Some investigators, in exploring the use of collagen tubes, being a natural biodegradable material, found either allogenicity or xenogenicity and immune responses that may inhibit nerve regeneration. Processed porcine collagen (PPC) is a new inert and biodegradable material that has a favorable effect on wound healing, as demonstrated by experiments on other tissues. The aim of our study was to compare the healing of nerve sutures with PPC tubes with conventional end-to-end sutures. In our experiments, we reconstructed the saphenous nerves of 27 rabbits. In series 1 (n = 12) and 2 (n = 12), PPC tubes were slid over an end-to-end nerve suture without or with a 10-mm nerve gap, respectively. In series 3 (n = 12), conventional suturing was performed in the collateral saphenous nerves of the animals of series 1. Epineurial suturing was performed. Three other non-operated saphenous nerves served as controls. The healing was studied after 3, 6, and 12 months in sections stained by monoclonal antibodies and by conventional histologic staining. Morphometric analysis of the regenerating axons was done by using confocal scanning laser microscopy (CLSM). Data analysis was carried out using a software program especially developed for this purpose. All results were evaluated statistically. Our results showed that during the healing period in the distal nerve stump, the number of axons of the PPC procedure with a 10-mm gap was significantly higher than that in the procedure without a gap. At 12 months, the mean number of axons of all procedures was significantly lower than in the non-operated nerve, and the mean axon diameter in all distal stumps did not differ significantly from that of the non-operated nerve. In the distal nerve stump, the ratio of total axon area to total fascicle area in the PPC procedure with a gap was significantly higher than that in the conventional suturing procedure. After 12 months, there was no significant difference between the percentages of axon outgrowth of the PPC procedure without a gap, the conventional suturing procedure, and the non-operated nerve (100%). The percentage of axon outgrowth in PPC with a gap was significantly higher than in the other procedures.
Collapse
Affiliation(s)
- G C Heijke
- Department of Experimental Surgery, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
| | | | | | | |
Collapse
|
43
|
Rangappa N, Romero A, Nelson KD, Eberhart RC, Smith GM. Laminin-coated poly(L-lactide) filaments induce robust neurite growth while providing directional orientation. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2000; 51:625-34. [PMID: 10880110 DOI: 10.1002/1097-4636(20000915)51:4<625::aid-jbm10>3.0.co;2-u] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Cellular channels during development and after peripheral nerve injury are thought to provide guidance cues to growing axons. In tissue culture where these cues are absent, neurites from dorsal root ganglion neurons grow with a radial distribution. To induce directional axonal growth and to enhance the rate of axonal growth after injury, we have designed microfilaments of poly(L-lactide). We demonstrate that dorsal root ganglia grown on these filaments in vitro extend longitudinally oriented neurites in a manner similar to native peripheral nerves. The extent of neurite growth was significantly higher on laminin-coated filaments compared with uncoated and poly-L-lysine-coated filaments. As high as 5.8 +/- 0.2 mm growth was observed on laminin-coated filaments compared with 2.0 +/- 0.2 mm on uncoated and 2.2 +/- 0.3 mm on poly-L-lysine-coated filaments within 8 days. Schwann cells were found to grow on all types of filaments. They were, however, absent in the leading edges of growth on laminin-coated filaments. Photolysis of Schwann cells caused a significant reduction in the neurite length on all types of filaments. Laminin-coated filaments, however, induced significantly longer neurites compared with uncoated and/or poly-L-lysine-coated filaments even in the absence of Schwann cells. Our results suggest that laminin-coated poly(L-lactide) filaments are suitable for inducing directional and enhanced axonal growth. Implants designed by arranging these microfilaments into bundles should aid regenerating axons by providing guidance cues and channels to organize matrix deposition, cell migration, axon growth, and improve functional recovery.
Collapse
Affiliation(s)
- N Rangappa
- Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, Dallas, Texas 75235-9130, USA
| | | | | | | | | |
Collapse
|
44
|
den Dunnen WF, Meek MF, Grijpma DW, Robinson PH, Schakenraad JM. In vivo and in vitro degradation of poly[(50)/(50) ((85)/(15)(L)/(D))LA/epsilon-CL], and the implications for the use in nerve reconstruction. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2000; 51:575-85. [PMID: 10880105 DOI: 10.1002/1097-4636(20000915)51:4<575::aid-jbm5>3.0.co;2-z] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Nerve guides can be used for the reconstruction of peripheral nerve defects. After serving their function, nerve guides should degrade. p[(50)/(50) ((85)/(15)(L)/(D))LA/epsilon-CL] degrades completely within 1 year without the formation of a slow degrading crystalline fraction. Although the tensile strength (TS) of a p[(50)/(50) ((85)/(15)(L)/(D))LA/epsilon-CL] nerve guide is negligible after 2 months, nerve regeneration across a 1-cm gap in the sciatic nerve of the rat is faster and qualitatively better than after reconstruction using autologous nerve grafts. During degradation p[(50)/(50) ((85)/(15)(L)/(D))LA/epsilon-CL] swells, especially during the first 3 months. This can have a negative influence on the regenerating nerve. p[(50)/(50) ((85)/(15)(L)/(D))LA/epsilon-CL] nerve guides could only be used in the clinical situation in case of short nerve gaps (several mm) in small nerves (for instance digital nerves). Refinements will be needed to successfully reconstruct longer nerve gaps (several cm).
Collapse
Affiliation(s)
- W F den Dunnen
- Department of Pathology, Groningen University Hospital, Hanzeplein 1, 9713 GZ Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
45
|
Abstract
Tissue engineering in the peripheral nervous system unites efforts by physicians, engineers, and biologists to create either natural or synthetic tubular nerve guidance channels as alternatives to nerve autografts for the repair of peripheral nerve defects. Guidance channels help direct axons sprouting from the regenerating nerve end, provide a conduit for diffusion of neurotropic and neurotrophic factors secreted by the damaged nerve stumps, and minimize infiltration of fibrous tissue. In addition to efforts to control these physical characteristics of nerve guidance channels, researchers are optimizing the incorporation of biologic factors and engineering interactive biomaterial that can specifically stimulate the regeneration process. Current and future research will ultimately result in biologically active and interactive nerve guidance channels that can support and enhance peripheral nerve regeneration over longer, more clinically relevant defect lengths.
Collapse
Affiliation(s)
- T W Hudson
- Department of Chemical Engineering, University of Texas at Austin, Austin, Texas 78712, USA
| | | | | |
Collapse
|
46
|
Chamberlain LJ, Yannas IV, Hsu HP, Strichartz GR, Spector M. Near-terminus axonal structure and function following rat sciatic nerve regeneration through a collagen-GAG matrix in a ten-millimeter gap. J Neurosci Res 2000; 60:666-77. [PMID: 10820438 DOI: 10.1002/(sici)1097-4547(20000601)60:5<666::aid-jnr12>3.0.co;2-0] [Citation(s) in RCA: 114] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The objectives of this study were to evaluate the regenerated axon structure at near-terminal locations in the peroneal and tibial branches 1 year following implantation of several tubular devices in a 10-mm gap in the adult rat sciatic nerve and to determine the extent of recovery of selected sensory and motor functions. The devices were collagen and silicone tubes implanted alone or filled with a porous collagen-glycosaminoglycan matrix. Intact contralateral nerves and autografts were used as controls. Nerves were retrieved at 30 and 60 weeks postoperatively for histological evaluation of the number and diameter of regenerated axons proximal and distal to the gap and in the tibial and peroneal nerve branches, near the termination point. Several functional evaluation methods were employed: gait analysis, pinch test, muscle circumference, and response to electrical stimulation. A notable finding was that the matrix-filled collagen tube group had a significantly greater number of large-diameter myelinated axons (> or =6 microm in diameter) in the distal nerve branches than any other group, including the autograft group. These results were consistent with previously reported electrophysiological measurements that showed that the action potential amplitude for the A fibers in the matrix-filled collagen tube group was greater than for the autograft control group. Functional testing revealed the existence of both sensory and motor recovery following peripheral nerve regeneration through all devices; however, the tests employed in this study did not show differences among the groups with regeneration. Electrical stimulation in vivo showed that threshold parameters to elicit muscle twitch were the same for reinnervating and control nerves. The investigation is of importance in showing for the first time the superiority of a specific fully resorbable off-the-shelf device over an autograft for bridging gaps in peripheral nerve, with respect to the near-terminus axonal structure.
Collapse
Affiliation(s)
- L J Chamberlain
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge 02139, USA
| | | | | | | | | |
Collapse
|
47
|
Mohammad J, Shenaq J, Rabinovsky E, Shenaq S. Modulation of peripheral nerve regeneration: a tissue-engineering approach. The role of amnion tube nerve conduit across a 1-centimeter nerve gap. Plast Reconstr Surg 2000; 105:660-6. [PMID: 10697174 DOI: 10.1097/00006534-200002000-00027] [Citation(s) in RCA: 90] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A new type of a biodegradable nerve graft conduit material, the amnion tube, has been developed in our laboratory. To test the tube in the peripheral nerve regeneration process, it was initially applied across a 1-cm sciatic nerve gap in rats and was compared with other nerve conduit materials. We used male Sprague-Dawley rats as our animal model. The experiment included 66 rats that were randomly assigned into five groups: autograft (n = 17), amnion tube (n = 19), silicone tube (n = 20), no repair (n = 7), and sham group (n = 3). The process of peripheral nerve regeneration was evaluated at 2, 4, 10, and 17 weeks following injury and repair by using morphologic and functional assessments of the outcome of nerve regeneration in each animal. Nerve regeneration across the amnion tube nerve conduit was comparable with that seen in autograft and superior to that of the silicone group. A uniform nerve tissue was seen filling and crossing the amnion conduit, and the regenerated nerve from the proximal stump reached the distal end and was undifferentiated from the normal nerve tissues. At 4 months, the amnion tube biodegraded and no longer could be identified and differentiated from the nerve tissues. The amnion tube animal group showed a number of axons very close to that in the nerve autograft group (37,157 versus 33,054). Functional recovery at a 2- to 4-week interval was significantly statistically higher only in the amnion tube animal group (p = 0.01). However, the improvement disappeared between 10 and 17 weeks. In conclusion, the amnion tube is a potential ideal nerve conduit material secondary to its unique characteristics: it contains important neurotropic factors, is biodegradable, provokes a very weak immune response, is semiflexible, is readily available, and is easily manufactured into different sizes and diameters.
Collapse
Affiliation(s)
- J Mohammad
- Division of Plastic Surgery, at the Baylor College of Medicine, Houston, Texas, USA.
| | | | | | | |
Collapse
|
48
|
|
49
|
Gautier SE, Oudega M, Fragoso M, Chapon P, Plant GW, Bunge MB, Parel JM. Poly(alpha-hydroxyacids) for application in the spinal cord: resorbability and biocompatibility with adult rat Schwann cells and spinal cord. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 1998; 42:642-54. [PMID: 9827690 DOI: 10.1002/(sici)1097-4636(19981215)42:4<642::aid-jbm22>3.0.co;2-k] [Citation(s) in RCA: 94] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Future surgical strategies to restore neurological function in the damaged human spinal cord may involve replacement of nerve tissue with cultured Schwann cells using biodegradable guiding implants. We have studied the in vitro and in vivo degradability of various aliphatic polyesters as well as their effects on rat Schwann cells in vitro and on spinal cord tissue in vivo. In vitro, cylinders made of poly(D,L-lactic-co-glycolic acid) 50:50 (PLA25GA50) started to degrade at 7 days, compared with 28 days for cylinders made of poly(D,L-lactic acid) (PLA50). This faster degradation of PLA25GA50 was reflected by a much higher absorption of water. In vivo, after implantation of PLA25GA50 or PLA50 cylinders between the stumps of a completely transected adult rat spinal cord, the decrease in molecular weight of both polymers was similar to that found in vitro. In vitro degradation of poly(L-lactic acid) (PLA100) mixed with increasing amounts of PLA100 oligomers also was determined. The degradation rate of PLA100 mixed with 30% oligomers was found to be similar to that of PLA50. In vitro, PLA25GA50 and the breakdown products had no adverse effect on the morphology, survival, and proliferation of cultured rat Schwann cells. In vivo, PLA25GA50 cylinders were integrated into the spinal tissue 2 weeks after implantation, unlike PLA50 cylinders. At all time points after surgery, the glial and inflammatory response near the lesion site was largely similar in both experimental and control animals. At time points later than 1 week, neurofilament-positive fibers were found within PLA25GA50 cylinders or the remains thereof. Growth-associated protein 43, which is indicative of regenerating axons, was observed in fibers in the vicinity of the injury site and in the remains of PLA25GA50 cylinders. The results suggest that poly(alpha-hydroxyacids) are likely candidates for application in spinal cord regeneration paradigms involving Schwann cells.
Collapse
Affiliation(s)
- S E Gautier
- Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami School of Medicine, Florida 33136, USA
| | | | | | | | | | | | | |
Collapse
|
50
|
Chamberlain LJ, Yannas IV, Hsu HP, Strichartz G, Spector M. Collagen-GAG substrate enhances the quality of nerve regeneration through collagen tubes up to level of autograft. Exp Neurol 1998; 154:315-29. [PMID: 9878170 DOI: 10.1006/exnr.1998.6955] [Citation(s) in RCA: 152] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Peripheral nerve regeneration was studied across a tubulated 10-mm gap in the rat sciatic nerve using histomorphometry and electrophysiological measurements of A-fiber, B-fiber, and C-fiber peaks of the evoked action potentials. Tubes fabricated from large-pore collagen (max. pore diameter, 22 nm), small-pore collagen (max. pore diameter, 4 nm), and silicone were implanted either saline-filled or filled with a highly porous, collagen-glycosaminoglycan (CG) matrix. The CG matrix was deliberately synthesized, based on a previous optimization study, to degrade with a half-life of about 6 weeks and to have a very high specific surface through a combination of high pore volume fraction (0.95) and relatively small average pore diameter (35 microm). Nerves regenerated through tubes fabricated from large-pore collagen and filled with the CG matrix had significantly more large-diameter axons, more total axons, and significantly higher A-fiber conduction velocities than any other tubulated group; and, although lower than normal, their histomorphometric and electrophysiological properties were statistically indistinguishable from those of the autograft control. Although the total number of myelinated axons in nerves regenerated by tubulation had reached a plateau by 30 weeks, the number of axons with diameter larger than 6 microm, which have been uniquely associated with the A-fiber peak of the action potential, continued to increase at substantial rates through the completion of the study (60 weeks). The kinetic data strongly suggest that a nerve trunk maturation process, not previously reported in studies of the tubulated 10-mm gap in the rat sciatic nerve, and consisting in increase of axonal tissue area with decrease in total tissue area, continues beyond 60 weeks after injury, resulting in a nerve trunk which increasingly approaches the structure of the normal control.
Collapse
Affiliation(s)
- L J Chamberlain
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, 02139, USA
| | | | | | | | | |
Collapse
|