1
|
Naresh NK, Misener S, Zhang Z, Yang C, Ruh A, Bertolino N, Epstein FH, Collins JD, Markl M, Procissi D, Carr JC, Allen BA. Cardiac MRI Myocardial Functional and Tissue Characterization Detects Early Cardiac Dysfunction in a Mouse Model of Chemotherapy-Induced Cardiotoxicity. NMR IN BIOMEDICINE 2020; 33:e4327. [PMID: 32567177 DOI: 10.1002/nbm.4327] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 04/14/2020] [Accepted: 05/06/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Doxorubicin and doxorubicin-trastuzumab combination chemotherapy have been associated with cardiotoxicity that eventually leads to heart failure and may limit dose-effective cancer treatment. Current diagnostic strategies rely on decreased ejection fraction (EF) to diagnose cardiotoxicity. PURPOSE The aim of this study is to explore the potential of cardiac MR (CMR) imaging to identify imaging biomarkers in a mouse model of chemotherapy-induced cardiotoxicity. METHODS A cumulative dose of 25 mg/kg doxorubicin was administered over three weeks using subcutaneous pellets (n = 9, Dox). Another group (n = 9) received same dose of Dox and a total of 10 mg/kg trastuzumab (DT). Mice were imaged at baseline, 5/6 weeks and 10 weeks post-treatment on a 7T MRI system. The protocol included short-axis cine MRI covering the left ventricle (LV) and mid-ventricular short-axis tissue phase mapping (TPM), pre- and post-contrast T1 mapping, T2 mapping and Displacement Encoding with Stimulated Echoes (DENSE) strain encoded MRI. EF, peak myocardial velocities, native T1, T2, extracellular volume (ECV), and myocardial strain were quantified. N = 7 mice were sacrificed for histopathologic assessment of apoptosis at 5/6 weeks. RESULTS Global peak systolic longitudinal velocity was reduced at 5/6 weeks in Dox (0.6 ± 0.3 vs 0.9 ± 0.3, p = 0.02). In the Dox group, native T1 was reduced at 5/6 weeks (1.3 ± 0.2 ms vs 1.6 ± 0.2 ms, p = 0.02), and relatively normalized at week 10 (1.4 ± 0.1 ms vs 1.6 ± 0.2 ms, p > 0.99). There was no change in EF and other MRI parameters and histopathologic results demonstrated minimal apoptosis in all mice (~1-2 apoptotic cell/high power field), suggesting early-stage cardiotoxicity. CONCLUSIONS In a mouse model of chemotherapy-induced cardiotoxicity using doxorubicin and trastuzumab, advanced CMR shows promise in identifying treatment-related decrease in myocardial velocity and native T1 prior to the onset of cardiomyocyte apoptosis and reduction of EF.
Collapse
Affiliation(s)
- Nivedita K Naresh
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Sol Misener
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Zhouli Zhang
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Cynthia Yang
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Alexander Ruh
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Nicola Bertolino
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Frederick H Epstein
- Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Jeremy D Collins
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Michael Markl
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
- McCormick School of Engineering, Northwestern University, Chicago, IL, USA
| | - Daniele Procissi
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - James C Carr
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| | - Bradley A Allen
- Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA
| |
Collapse
|
2
|
Vanhoutte L, Gerber BL, Gallez B, Po C, Magat J, Balligand JL, Feron O, Moniotte S. High field magnetic resonance imaging of rodents in cardiovascular research. Basic Res Cardiol 2016; 111:46. [PMID: 27287250 DOI: 10.1007/s00395-016-0565-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 06/01/2016] [Indexed: 02/07/2023]
Abstract
Transgenic and gene knockout rodent models are primordial to study pathophysiological processes in cardiovascular research. Over time, cardiac MRI has become a gold standard for in vivo evaluation of such models. Technical advances have led to the development of magnets with increasingly high field strength, allowing specific investigation of cardiac anatomy, global and regional function, viability, perfusion or vascular parameters. The aim of this report is to provide a review of the various sequences and techniques available to image mice on 7-11.7 T magnets and relevant to the clinical setting in humans. Specific technical aspects due to the rise of the magnetic field are also discussed.
Collapse
Affiliation(s)
- Laetitia Vanhoutte
- Department of Paediatric Cardiology, Cliniques universitaires Saint Luc, Université Catholique de Louvain (UCL), Brussels, Belgium. .,Pole of Pharmacology and Therapeutics (FATH), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCL), Brussels, Belgium.
| | - Bernhard L Gerber
- Division of Cardiology, Cliniques universitaires Saint Luc, Université Catholique de Louvain (UCL), Brussels, Belgium.,Pole of Cardiovascular Research (CARD), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCL), Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Unit (REMA), Louvain Drug Research Institute (LDRI), Université Catholique de Louvain (UCL), Brussels, Belgium
| | - Chrystelle Po
- CNRS, ICube, FMTS, Institut de Physique Biologique, Faculté de Médecine, Université de Strasbourg, Strasbourg, France
| | - Julie Magat
- L'Institut de RYthmologie et de Modélisation Cardiaque (LIRYC), Inserm U1045, Bordeaux, France
| | - Jean-Luc Balligand
- Pole of Pharmacology and Therapeutics (FATH), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCL), Brussels, Belgium
| | - Olivier Feron
- Pole of Pharmacology and Therapeutics (FATH), Institute of Experimental and Clinical Research (IREC), Université Catholique de Louvain (UCL), Brussels, Belgium
| | - Stéphane Moniotte
- Department of Paediatric Cardiology, Cliniques universitaires Saint Luc, Université Catholique de Louvain (UCL), Brussels, Belgium
| |
Collapse
|
3
|
Reproducibility and observer variability of tissue phase mapping for the quantification of regional myocardial velocities. Int J Cardiovasc Imaging 2016; 32:1227-34. [PMID: 27116238 DOI: 10.1007/s10554-016-0894-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Accepted: 04/11/2016] [Indexed: 10/21/2022]
Abstract
To systematically investigate the reproducibility of global and segmental left ventricular (LV) velocities derived from tissue phase mapping (TPM). Breath held and ECG synchronized TPM data (spatial/temporal resolution = 2 × 2 mm(2)/20.8 ms) were acquired in 18 healthy volunteers. To analyze scan-rescan variability, TPM was repeated in all subjects during a second visit separated by 16 ± 5 days. Data analysis included LV segmentation, and quantification of global and regional (AHA 16-segment modal) metrics of LV function [velocity-time curves, systolic and diastolic peak and time-to-peak (TTP) velocities] for radial (Vr), long-axis (Vz) and circumferential (VΦ) LV velocities. Mean velocity time curves in basal, mid-ventricular, and apical locations showed highly similar LV motion patterns for all three velocity components (Vr, VΦ, Vz) for scan and rescan. No significant differences for both systolic and diastolic peak and TTP myocardial velocities were observed. Segmental analysis revealed similar regional peak Vr and Vz during both systole and diastole except for three LV segments (p = 0.045, p = 0.033, and p = 0.009). Excellent (p < 0.001) correlations between scans and rescan for peak Vr (R(2) = 0.92), peak Vz (R(2) = 0.90), radial TTP (R(2) = 0.91) and long-axis TTP (R(2) = 0.88) confirmed good agreement. Bland-Altman analysis demonstrated excellent intra-observer and good inter-observer analysis agreement but increased variability for long axis peak velocities. TPM based analysis of global and regional myocardial velocities can be performed with good reproducibility. Robustness of regional quantification of long-axis velocities was limited but spatial velocity distributions across the LV could reliably be replicated.
Collapse
|
4
|
Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV. Cardiovascular magnetic resonance phase contrast imaging. J Cardiovasc Magn Reson 2015; 17:71. [PMID: 26254979 PMCID: PMC4529988 DOI: 10.1186/s12968-015-0172-7] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 07/16/2015] [Indexed: 11/10/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) phase contrast imaging has undergone a wide range of changes with the development and availability of improved calibration procedures, visualization tools, and analysis methods. This article provides a comprehensive review of the current state-of-the-art in CMR phase contrast imaging methodology, clinical applications including summaries of past clinical performance, and emerging research and clinical applications that utilize today's latest technology.
Collapse
Affiliation(s)
- Krishna S Nayak
- Ming Hsieh Department of Electrical Engineering, University of Southern California, 3740 McClintock Ave, EEB 406, Los Angeles, California, 90089-2564, USA.
| | - Jon-Fredrik Nielsen
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | | | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, IL, USA.
| | - Peter D Gatehouse
- Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, London, UK.
| | - Rene M Botnar
- Cardiovascular Imaging, Imaging Sciences Division, Kings's College London, London, UK.
| | - David Saloner
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
| | - Christine Lorenz
- Center for Applied Medical Imaging, Siemens Corporation, Baltimore, MD, USA.
| | - Han Wen
- Imaging Physics Laboratory, National Heart Lung and Blood Institute, Bethesda, MD, USA.
| | - Bob S Hu
- Palo Alto Medical Foundation, Palo Alto, CA, USA.
| | - Frederick H Epstein
- Departments of Radiology and Biomedical Engineering, University of Virginia, Charlottesville, VA, USA.
| | - John N Oshinski
- Departments of Radiology and Biomedical Engineering, Emory University School of Medicine, Atlanta, GA, USA.
| | - Subha V Raman
- Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA.
| |
Collapse
|
5
|
Bakermans AJ, Abdurrachim D, Moonen RPM, Motaal AG, Prompers JJ, Strijkers GJ, Vandoorne K, Nicolay K. Small animal cardiovascular MR imaging and spectroscopy. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2015; 88-89:1-47. [PMID: 26282195 DOI: 10.1016/j.pnmrs.2015.03.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 03/09/2015] [Accepted: 03/09/2015] [Indexed: 06/04/2023]
Abstract
The use of MR imaging and spectroscopy for studying cardiovascular disease processes in small animals has increased tremendously over the past decade. This is the result of the remarkable advances in MR technologies and the increased availability of genetically modified mice. MR techniques provide a window on the entire timeline of cardiovascular disease development, ranging from subtle early changes in myocardial metabolism that often mark disease onset to severe myocardial dysfunction associated with end-stage heart failure. MR imaging and spectroscopy techniques play an important role in basic cardiovascular research and in cardiovascular disease diagnosis and therapy follow-up. This is due to the broad range of functional, structural and metabolic parameters that can be quantified by MR under in vivo conditions non-invasively. This review describes the spectrum of MR techniques that are employed in small animal cardiovascular disease research and how the technological challenges resulting from the small dimensions of heart and blood vessels as well as high heart and respiratory rates, particularly in mice, are tackled.
Collapse
Affiliation(s)
- Adrianus J Bakermans
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Desiree Abdurrachim
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rik P M Moonen
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Abdallah G Motaal
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Jeanine J Prompers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Gustav J Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Katrien Vandoorne
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Klaas Nicolay
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| |
Collapse
|
6
|
Meßner NM, Zöllner FG, Kalayciyan R, Schad LR. Pre-clinical functional Magnetic Resonance Imaging Part II: The heart. Z Med Phys 2014; 24:307-22. [PMID: 25023418 DOI: 10.1016/j.zemedi.2014.06.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Revised: 05/09/2014] [Accepted: 06/17/2014] [Indexed: 12/21/2022]
Abstract
One third of all deaths worldwide in 2008 were caused by cardiovascular diseases (CVD), and the incidence of CVD related deaths rises ever more. Thus, improved imaging techniques and modalities are needed for the evaluation of cardiac morphology and function. Cardiac magnetic resonance imaging (CMRI) is a minimally invasive technique that is increasingly important due to its high spatial and temporal resolution, its high soft tissue contrast and its ability of functional and quantitative imaging. It is widely accepted as the gold standard of cardiac functional analysis. In the short period of small animal MRI, remarkable progress has been achieved concerning new, fast imaging schemes as well as purpose-built equipment. Dedicated small animal scanners allow for tapping the full potential of recently developed animal models of cardiac disease. In this paper, we review state-of-the-art cardiac magnetic resonance imaging techniques and applications in small animals at ultra-high fields (UHF).
Collapse
Affiliation(s)
- Nadja M Meßner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
| | - Raffi Kalayciyan
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|
7
|
Akki A, Gupta A, Weiss RG. Magnetic resonance imaging and spectroscopy of the murine cardiovascular system. Am J Physiol Heart Circ Physiol 2013; 304:H633-48. [PMID: 23292717 DOI: 10.1152/ajpheart.00771.2011] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Magnetic resonance imaging (MRI) has emerged as a powerful and reliable tool to noninvasively study the cardiovascular system in clinical practice. Because transgenic mouse models have assumed a critical role in cardiovascular research, technological advances in MRI have been extended to mice over the last decade. These have provided critical insights into cardiac and vascular morphology, function, and physiology/pathophysiology in many murine models of heart disease. Furthermore, magnetic resonance spectroscopy (MRS) has allowed the nondestructive study of myocardial metabolism in both isolated hearts and in intact mice. This article reviews the current techniques and important pathophysiological insights from the application of MRI/MRS technology to murine models of cardiovascular disease.
Collapse
Affiliation(s)
- Ashwin Akki
- Division of Cardiology, Department of Medicine, and Division of Magnetic Resonance Research, Department of Radiology, The Johns Hopkins University, School of Medicine, Baltimore, MD, USA
| | | | | |
Collapse
|
8
|
Jung B, Odening KE, Dall’Armellina E, Föll D, Menza M, Markl M, Schneider JE. A quantitative comparison of regional myocardial motion in mice, rabbits and humans using in-vivo phase contrast CMR. J Cardiovasc Magn Reson 2012; 14:87. [PMID: 23270566 PMCID: PMC3579745 DOI: 10.1186/1532-429x-14-87] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2012] [Accepted: 12/06/2012] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Genetically manipulated animals like mice or rabbits play an important role in the exploration of human cardiovascular diseases. It is therefore important to identify animal models that closely mimic physiological and pathological human cardiac function. METHODS In-vivo phase contrast cardiovascular magnetic resonance (CMR) was used to measure regional three-directional left ventricular myocardial motion with high temporal resolution in mice (N=18), rabbits (N=8), and humans (N=20). Radial, long-axis, and rotational myocardial velocities were acquired in left ventricular basal, mid-ventricular, and apical short-axis locations. RESULTS Regional analysis revealed different patterns of motion: 1) In humans and rabbits, the apex showed slower radial velocities compared to the base. 2) Significant differences within species were seen in the pattern of long-axis motion. Long-axis velocities during systole were fairly homogeneously distributed in mice, whereas humans showed a dominant component in the lateral wall and rabbits in the base. 3) Rotational velocities and twist showed the most distinct patterns in both temporal evolution and relative contribution of base, mid-ventricle and apex, respectively. Interestingly, a marked difference in rotational behavior during early-systole was found in mice, which exhibited clockwise rotation in all slice locations compared to counter-clockwise rotation in rabbits and humans. CONCLUSIONS Phase contrast CMR revealed subtle, but significantly different regional myocardial motion patterns in mice, rabbits and humans. This finding has to be considered when investigating myocardial motion pattern in small animal models of heart disease.
Collapse
Affiliation(s)
- Bernd Jung
- Department of Radiology, Medical Physics, University Medical Center, Freiburg, Germany
| | - Katja E Odening
- Department of Cardiology, University Medical Center, Freiburg, Germany
| | | | - Daniela Föll
- Department of Cardiology, University Medical Center, Freiburg, Germany
| | - Marius Menza
- Department of Radiology, Medical Physics, University Medical Center, Freiburg, Germany
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | | |
Collapse
|
9
|
Espe EKS, Aronsen JM, Skrbic B, Skulberg VM, Schneider JE, Sejersted OM, Zhang L, Sjaastad I. Improved MR phase-contrast velocimetry using a novel nine-point balanced motion-encoding scheme with increased robustness to eddy current effects. Magn Reson Med 2012; 69:48-61. [PMID: 22392844 DOI: 10.1002/mrm.24226] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2011] [Revised: 01/17/2012] [Accepted: 02/04/2012] [Indexed: 01/23/2023]
Abstract
Phase-contrast MRI (PC-MRI) velocimetry is a noninvasive, high-resolution motion assessment tool. However, high motion sensitivity requires strong motion-encoding magnetic gradients, making phase-contrast-MRI prone to baseline shift artifacts due to the generation of eddy currents. In this study, we propose a novel nine-point balanced velocity-encoding strategy, designed to be more accurate in the presence of strong and rapidly changing gradients. The proposed method was validated using a rotating phantom, and its robustness and precision were explored and compared with established approaches through computer simulations and in vivo experiments. Computer simulations yielded a 39-57% improvement in velocity-noise ratio (corresponding to a 27-33% reduction in measurement error), depending on which method was used for comparison. Moreover, in vivo experiments confirmed this by demonstrating a 26-53% reduction in accumulated velocity error over the R-R interval. The nine-point balanced phase-contrast-MRI-encoding strategy is likely useful for settings where high spatial and temporal resolution and/or high motion sensitivity is required, such as in high-resolution rodent myocardial tissue phase mapping.
Collapse
Affiliation(s)
- Emil K S Espe
- Institute for Experimental Medical Research, Oslo University Hospital and University of Oslo, Oslo, Norway.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Dall'Armellina E, Jung BA, Lygate CA, Neubauer S, Markl M, Schneider JE. Improved method for quantification of regional cardiac function in mice using phase-contrast MRI. Magn Reson Med 2012; 67:541-51. [PMID: 21674616 PMCID: PMC3378699 DOI: 10.1002/mrm.23022] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2011] [Revised: 04/04/2011] [Accepted: 05/05/2011] [Indexed: 11/08/2022]
Abstract
Phase-contrast magnetic resonance imaging is a technique that allows for characterization of regional cardiac function and for measuring transmural myocardial velocities in human hearts with high temporal and spatial resolution. The application of this technique (also known as tissue phase mapping) to murine hearts has been very limited so far. The aim of our study was to implement and to optimize tissue phase mapping for a comprehensive assessment of murine transmural wall motion. Baseline values for regional motion patterns in mouse hearts, based on the clinically used American Heart Association's 17-segment model, were established, and a detailed motion analysis of mouse heart for the entire cardiac cycle (including epicardial and endocardial motion patterns) is provided. Black-blood contrast was found to be essential to obtain reproducible velocity encoding. Tissue phase mapping of the mouse heart permits the detailed assessment of regional myocardial velocities. While a proof-of-principle application in a murine ischemia-reperfusion model was performed, future studies are warranted to assess its potential for the investigation of systolic and diastolic functions in genetically and surgically manipulated mouse models of human heart disease.
Collapse
Affiliation(s)
- Erica Dall'Armellina
- Department of Cardiovascular Medicine, University of OxfordOxford, United Kingdom
| | - Bernd A Jung
- Department of Radiology, Medical Physics, University Hospital FreiburgGermany
| | - Craig A Lygate
- Department of Cardiovascular Medicine, University of OxfordOxford, United Kingdom
| | - Stefan Neubauer
- Department of Cardiovascular Medicine, University of OxfordOxford, United Kingdom
| | - Michael Markl
- Department of Radiology, Medical Physics, University Hospital FreiburgGermany
| | - Jürgen E Schneider
- Department of Cardiovascular Medicine, University of OxfordOxford, United Kingdom
| |
Collapse
|
11
|
Abstract
High-resolution magnetic resonance cine imaging (cine-MRI) allows for a non-invasive assessment of ventricular function and mass in normal mice and in genetically and surgically modified mouse models of cardiac disease. The assessment of myocardial mass and function by cine-MRI does not rely on geometric assumptions, as the hearts are covered from the base to the apex, typically by a stack of two-dimensional images. The MR data acquisition is then followed by image segmentation of specific cine frames in each slice to obtain geometric and functional parameters, such as end-diastolic volume (EDV), end-systolic volume (ESV) or ejection fraction (EF). This technique has been well established in clinical routine application and it is now also becoming the reference method in experimental cardiovascular MRI. The cine images are typically acquired in short- and long-axis orientations of the heart to facilitate an accurate assessment of cardiac functional parameters. These views can be difficult to identify, particularly in animals with diseased hearts. Furthermore, data analysis can be the source of a systematic error, mainly for myocardial mass measurement. We have established protocols that allow for a quick and reproducible way of obtaining the relevant cardiac views for cine-MRI, and for accurate image analysis.
Collapse
|
12
|
Botnar RM, Makowski MR. Cardiovascular magnetic resonance imaging in small animals. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2012; 105:227-61. [PMID: 22137434 DOI: 10.1016/b978-0-12-394596-9.00008-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Noninvasive imaging studies involving small animals are becoming increasingly important in preclinical pharmacological, genetic, and biomedical cardiovascular research. Especially small animal magnetic resonance imaging (MRI) using high field and clinical MRI systems has gained significant importance in recent years. Compared to other imaging modalities, like computer tomography, MRI can provide an excellent soft tissue contrast, which enables the characterization of different kinds of tissues without the use of contrast agents. In addition, imaging can be performed with high spatial and temporal resolution. Small animal MRI cannot only provide anatomical information about the beating murine heart; it can also provide functional and molecular information, which makes it a unique imaging modality. Compared to clinical MRI examinations in humans, small animal MRI is associated with additional challenges. These included a smaller size of all cardiovascular structures and a up to ten times higher heart rate. Dedicated small animal monitoring devices make a reliable cardiac triggering and respiratory gating feasible. MRI in combination with molecular probes enables the noninvasive imaging of biological processes at a molecular level. Different kinds of iron oxide or gadolinium-based contrast agents can be used for this purpose. Compared to other molecular imaging modalities, like single photon emission computed tomography (SPECT) and positron emission tomography (PET), MRI can also provide imaging with high spatial resolution, which is of high importance for the assessment of the cardiovascular system. The sensitivity for detection of MRI contrast agents is however lower compared to sensitivity of radiation associated techniques like PET and SPECT. This chapter is divided into the following sections: (1) "Introduction," (2) "Principals of Magnetic Resonance Imaging," (3) "MRI Systems for Preclinical Imaging and Experimental Setup," and (4) "Cardiovascular Magnetic Resonance Imaging."
Collapse
Affiliation(s)
- René M Botnar
- Division of Imaging Sciences, King's College London, London, United Kingdom
| | | |
Collapse
|
13
|
Zhong X, Gibberman LB, Spottiswoode BS, Gilliam AD, Meyer CH, French BA, Epstein FH. Comprehensive cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE. J Cardiovasc Magn Reson 2011; 13:83. [PMID: 22208954 PMCID: PMC3278394 DOI: 10.1186/1532-429x-13-83] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2011] [Accepted: 12/30/2011] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Quantitative noninvasive imaging of myocardial mechanics in mice enables studies of the roles of individual genes in cardiac function. We sought to develop comprehensive three-dimensional methods for imaging myocardial mechanics in mice. METHODS A 3D cine DENSE pulse sequence was implemented on a 7T small-bore scanner. The sequence used three-point phase cycling for artifact suppression and a stack-of-spirals k-space trajectory for efficient data acquisition. A semi-automatic 2D method was adapted for 3D image segmentation, and automated 3D methods to calculate strain, twist, and torsion were employed. A scan protocol that covered the majority of the left ventricle in a scan time of less than 25 minutes was developed, and seven healthy C57Bl/6 mice were studied. RESULTS Using these methods, multiphase normal and shear strains were measured, as were myocardial twist and torsion. Peak end-systolic values for the normal strains at the mid-ventricular level were 0.29 ± 0.17, -0.13 ± 0.03, and -0.18 ± 0.14 for E(rr), E(cc), and E(ll), respectively. Peak end-systolic values for the shear strains were 0.00 ± 0.08, 0.04 ± 0.12, and 0.03 ± 0.07 for E(rc), E(rl), and E(cl), respectively. The peak end-systolic normalized torsion was 5.6 ± 0.9°. CONCLUSIONS Using a 3D cine DENSE sequence tailored for cardiac imaging in mice at 7 T, a comprehensive assessment of 3D myocardial mechanics can be achieved with a scan time of less than 25 minutes and an image analysis time of approximately 1 hour.
Collapse
Affiliation(s)
| | | | - Bruce S Spottiswoode
- MRC/UCT Medical Imaging Research Unit, University of Cape Town, Cape Town, South Africa
| | | | - Craig H Meyer
- Radiology Department, University of Virginia, Charlottesville, USA
- Biomedical Engineering Department, University of Virginia, Charlottesville, USA
| | - Brent A French
- Biomedical Engineering Department, University of Virginia, Charlottesville, USA
| | - Frederick H Epstein
- Radiology Department, University of Virginia, Charlottesville, USA
- Biomedical Engineering Department, University of Virginia, Charlottesville, USA
| |
Collapse
|
14
|
Schneider JE, Lanz T, Barnes H, Stork LA, Bohl S, Lygate CA, Ordidge RJ, Neubauer S. Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla. Magn Reson Med 2011; 65:60-70. [PMID: 20740650 PMCID: PMC3021721 DOI: 10.1002/mrm.22605] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequently limit the number of parameters available in one imaging session. Parallel imaging techniques to reduce acquisition times require coil arrays, which are technically challenging to design at ultrahigh magnetic field strengths. This work validates the use of an eight-channel volume phased-array coil for cardiac MRI in mice at 9.4 T. Two- and three-dimensional sequences were combined with parallel imaging techniques and used to quantify global cardiac function, T(1)-relaxation times and infarct sizes. Furthermore, the rapid acquisition of functional cine-data allowed for the first time in mice measurement of left-ventricular peak filling and ejection rates under intravenous infusion of dobutamine. The results demonstrate that a threefold accelerated data acquisition is generally feasible without compromising the accuracy of the results. This strategy may eventually pave the way for routine, multiparametric phenotyping of mouse hearts in vivo within one imaging session of tolerable duration.
Collapse
Affiliation(s)
- Jürgen E Schneider
- British Heart Foundation Experimental MR Unit (BMRU), Department of Cardiovascular Medicine, University of Oxford, Oxford OX3 7BN, United Kingdom.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Price AN, Cheung KK, Cleary JO, Campbell AE, Riegler J, Lythgoe MF. Cardiovascular magnetic resonance imaging in experimental models. Open Cardiovasc Med J 2010; 4:278-92. [PMID: 21331311 PMCID: PMC3040459 DOI: 10.2174/1874192401004010278] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2010] [Revised: 09/27/2010] [Accepted: 10/04/2010] [Indexed: 12/19/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) imaging is the modality of choice for clinical studies of the heart and vasculature, offering detailed images of both structure and function with high temporal resolution. Small animals are increasingly used for genetic and translational research, in conjunction with models of common pathologies such as myocardial infarction. In all cases, effective methods for characterising a wide range of functional and anatomical parameters are crucial for robust studies. CMR is the gold-standard for the non-invasive examination of these models, although physiological differences, such as rapid heart rate, make this a greater challenge than conventional clinical imaging. However, with the help of specialised magnetic resonance (MR) systems, novel gating strategies and optimised pulse sequences, high-quality images can be obtained in these animals despite their small size. In this review, we provide an overview of the principal CMR techniques for small animals for example cine, angiography and perfusion imaging, which can provide measures such as ejection fraction, vessel anatomy and local blood flow, respectively. In combination with MR contrast agents, regional dysfunction in the heart can also be identified and assessed. We also discuss optimal methods for analysing CMR data, particularly the use of semi-automated tools for parameter measurement to reduce analysis time. Finally, we describe current and emerging methods for imaging the developing heart, aiding characterisation of congenital cardiovascular defects. Advanced small animal CMR now offers an unparalleled range of cardiovascular assessments. Employing these methods should allow new insights into the structural, functional and molecular basis of the cardiovascular system.
Collapse
Affiliation(s)
- Anthony N Price
- UCL Centre for Advanced Biomedical Imaging, Department of Medicine and UCL Institute of Child Health, University College London, UK
| | | | | | | | | | | |
Collapse
|
16
|
Teh I, Golay X, Larkman DJ. PROPELLER for motion-robust imaging of in vivo mouse abdomen at 9.4 T. NMR IN BIOMEDICINE 2010; 23:1077-1086. [PMID: 20963802 DOI: 10.1002/nbm.1535] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
In vivo high-field MRI in the abdomen of small animals is technically challenging because of the small voxel sizes, short T(2) and physiological motion. In standard Cartesian sampling, respiratory and gastrointestinal motion can lead to ghosting artefacts. Although respiratory triggering and navigator echoes can either avoid or compensate for motion, they can lead to variable TRs, require invasive intubation and ventilation, or extend TEs. A self-navigated fast spin echo (FSE)-based periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) acquisition was implemented at 9.4 T to enable high-resolution in vivo MRI of mouse abdomen without the use of additional navigators or triggering. T(2)-weighted FSE-PROPELLER data were compared with single-shot FSE and multi-shot FSE data with and without triggering. Single-shot methods, although rapid and robust to motion, demonstrated strong blurring. Multi-shot FSE data showed better resolution, but suffered from marked blurring in the phase-encoding direction and motion in between shots, leading to ghosting artefacts. When respiratory triggering was used, motion artefacts were largely avoided. However, TRs and acquisition times were lengthened by up to approximately 20%. The PROPELLER data showed a 25% and 61% improvement in signal-to-noise ratio and contrast-to-noise ratio, respectively, compared with multi-shot FSE data, together with a 35% reduction in artefact power. A qualitative comparison between acquisition methods using diffusion-weighted imaging was performed. The results were similar, with the exception that respiratory triggering was unable to exclude major motion artefacts as a result of the sensitisation to motion by the diffusion gradients. The PROPELLER data were of consistently higher quality. Considerations specific to the use of PROPELLER at high field are discussed, including the selection of practical blade widths and the effects on contrast, resolution and artefacts.
Collapse
Affiliation(s)
- Irvin Teh
- Imaging Sciences Department, MRC Clinical Sciences Centre, Hammersmith Hospital, Imperial College, London, UK.
| | | | | |
Collapse
|
17
|
Le Y, Stein A, Berry C, Kellman P, Bennett EE, Taylor J, Lucas K, Kopace R, Chefd’Hotel C, Lorenz CH, Croisille P, Wen H. Simultaneous myocardial strain and dark-blood perfusion imaging using a displacement-encoded MRI pulse sequence. Magn Reson Med 2010; 64:787-98. [PMID: 20544714 PMCID: PMC2932773 DOI: 10.1002/mrm.22461] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2009] [Accepted: 03/01/2010] [Indexed: 11/06/2022]
Abstract
The purpose of this study is to develop and evaluate a displacement-encoded pulse sequence for simultaneous perfusion and strain imaging. Displacement-encoded images in two to three myocardial slices were repeatedly acquired using a single-shot pulse sequence for 3 to 4 min, which covers a bolus infusion of Gadolinium contrast. The magnitudes of the images were T(1) weighted and provided quantitative measures of perfusion, while the phase maps yielded strain measurements. In an acute coronary occlusion swine protocol (n = 9), segmental perfusion measurements were validated against microsphere reference standard with a linear regression (slope 0.986, R(2) = 0.765, Bland-Altman standard deviation = 0.15 mL/min/g). In a group of ST-elevation myocardial infarction patients (n = 11), the scan success rate was 76%. Short-term contrast washout rate and perfusion are highly correlated (R(2) = 0.72), and the pixelwise relationship between circumferential strain and perfusion was better described with a sigmoidal Hill curve than linear functions. This study demonstrates the feasibility of measuring strain and perfusion from a single set of images.
Collapse
Affiliation(s)
- Yuan Le
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Ashley Stein
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Colin Berry
- Western Infirmary & Associated Hospital, Dept. Cardiology, Glasgow, Scotland
| | - Peter Kellman
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Eric E. Bennett
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Joni Taylor
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Katherine Lucas
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Rael Kopace
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | | | | | - Pierre Croisille
- Departement de Radiologie, Hôpital Cardiologique et Pneumologique, L. Pradel, Lyon, France
| | - Han Wen
- National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
18
|
Zhong J, Yu X. Strain and torsion quantification in mouse hearts under dobutamine stimulation using 2D multiphase MR DENSE. Magn Reson Med 2010; 64:1315-22. [PMID: 20740659 DOI: 10.1002/mrm.22530] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2009] [Revised: 05/13/2010] [Accepted: 05/17/2010] [Indexed: 11/08/2022]
Abstract
In this study, a 2D multiphase magnetic resonance displacement encoding with stimulated echoes (DENSE) imaging and analysis method was developed for direct quantification of Lagrangian strain in the mouse heart. Using the proposed method, <10 ms temporal resolution and 0.56 mm in-plane resolution were achieved. A validation study that compared strain calculation by displacement encoding with stimulated echoes and by magnetic resonance tagging showed high correlation between the two methods (R(2) > 0.80). Regional ventricular wall strain and twist were characterized in mouse hearts at baseline and under dobutamine stimulation. Dobutamine stimulation induced significant increase in radial and circumferential strains and torsion at peak systole. A rapid untwisting was also observed during early diastole. This work demonstrates the capability of characterizing cardiac functional response to dobutamine stimulation in the mouse heart using 2D multiphase magnetic resonance displacement encoding with stimulated echoes.
Collapse
Affiliation(s)
- Jia Zhong
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | | |
Collapse
|
19
|
Makowski MR, Wiethoff AJ, Jansen CHP, Botnar RM. Cardiovascular MRI in small animals. Expert Rev Cardiovasc Ther 2010; 8:35-47. [PMID: 20014933 DOI: 10.1586/erc.09.126] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Imaging studies of cardiovascular disease in small rodents have become a prerequisite in preclinical cardiovascular research. Transgenic and gene-knockout models of cardiovascular diseases enables the investigation of the influence of single genes or groups of genes on disease pathogenesis. In addition, experimental and genetically altered models provide valuable in vivo platforms to investigate the efficacy of novel drugs and contrast agents. Owing to the excellent soft tissue contrast, high spatial and temporal resolution, as well as the tomographic nature of MRI, anatomy and function can be assessed with unique accuracy and reproducibility. Furthermore, using novel targeted MRI contrast agents, molecular changes associated with cardiovascular disease can be investigated in the same imaging session. This review focuses on recent advances in hardware, imaging sequences and probe design.
Collapse
Affiliation(s)
- Marcus R Makowski
- Division of Imaging Sciences, King's College London, 4th Floor, Lambeth Wing, St Thomas' Hospital, London SE1 7EH, UK.
| | | | | | | |
Collapse
|
20
|
Visualization of multidirectional regional left ventricular dynamics by high-temporal-resolution tissue phase mapping. J Magn Reson Imaging 2009; 29:1043-52. [DOI: 10.1002/jmri.21634] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
|
21
|
Strijkers GJ, Bouts A, Blankesteijn WM, Peeters THJM, Vilanova A, van Prooijen MC, Sanders HMHF, Heijman E, Nicolay K. Diffusion tensor imaging of left ventricular remodeling in response to myocardial infarction in the mouse. NMR IN BIOMEDICINE 2009; 22:182-190. [PMID: 18780284 DOI: 10.1002/nbm.1299] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The cardiac muscle architecture lies at the basis of the mechanical and electrical properties of the heart, and dynamic alterations in fiber structure are known to be of prime importance in healing and remodeling after myocardial infarction. In this study, left ventricular remodeling was characterized using diffusion tensor imaging (DTI) in a mouse model of myocardial infarction. Myocardial infarction was induced in mice by permanent ligation of the left anterior descending coronary artery. Serial ex vivo DTI measurements were performed 7, 14, 28, and 60 days after ligation. Apparent diffusion coefficient, fractional anisotropy, the three eigenvalues of the diffusion tensor, and the myofiber disarray served as readout parameters. After myocardial infarction, the mouse hearts displayed extreme wall thinning in the infarcted area, which covered large parts of the apex and extended into the free wall up to the equator. Average heart mass increased by 70% 7-60 days after infarction. Histological analysis showed that the infarct at 7 days consisted of unstructured tissue with residual necrosis and infiltration of macrophages and myofibroblasts. At 14 days after infarction, the necrotic tissue had disappeared and collagen fibers were starting to appear. From 28 to 60 days, the infarct had fully developed into a mature scar. DTI parameters showed dynamic changes as a function of time after infarction. The apparent diffusion coefficient in the infarcted region was lower than in remote regions and increased as a function of time after infarction. The fractional anisotropy was higher in the infarcted region and was maximum at 28 days, which was attributed to the development of structured collagen fibers. Myofiber disarray, which was analyzed by considering the alignment of fibers in neighboring voxels, was significantly higher in infarcted regions. DTI provides a valuable non-destructive tool for characterizing structural remodeling in diseased myocardium.
Collapse
Affiliation(s)
- Gustav J Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
| | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Zhong J, Liu W, Yu X. Characterization of three-dimensional myocardial deformation in the mouse heart: an MR tagging study. J Magn Reson Imaging 2008; 27:1263-70. [PMID: 18504746 DOI: 10.1002/jmri.21367] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
PURPOSE To develop a 3D MR tagging method that combines harmonic phase (HARP) and homogeneous strain analysis methods for quantification of regional myocardial wall motion in mice. MATERIALS AND METHODS 3D tagged images were acquired from seven C57BL/6 mice. Intersecting tag points were reconstructed and 3D strains were quantified at apical, midventricular, and basal levels. Circumferential and radial strains quantified with 2D MR tagging were compared with those calculated from 3D tagged images. RESULTS Our data showed significant heterogeneity in radial, circumferential, and shear strains. Longitudinal strain was more homogeneous. The circumferential-longitudinal shear strain, a unitless measure of ventricular torsion, was positive throughout the left ventricle. There were strong correlations between 2D and 3D studies at the basal and midventricular levels. CONCLUSION This work demonstrates the feasibility of 3D characterization of cardiac function in mouse via the combination of HARP and homogeneous strain analysis.
Collapse
Affiliation(s)
- Jia Zhong
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | | | | |
Collapse
|
23
|
Delfino JG, Johnson KR, Eisner RL, Eder S, Leon AR, Oshinski JN. Three-directional myocardial phase-contrast tissue velocity MR imaging with navigator-echo gating: in vivo and in vitro study. Radiology 2008; 246:917-25. [PMID: 18223122 DOI: 10.1148/radiol.2463062155] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The study protocol was HIPAA compliant and institutional review board approved. Informed consent was obtained from all participants. The purpose of the study was to prospectively validate the capability of navigator-echo-gated phase-contrast magnetic resonance (MR) imaging for measurement of myocardial velocities in a phantom and to prospectively use the phase-contrast MR sequence to measure three-directional velocity in the myocardium in vivo in volunteers and in patients scheduled for cardiac resynchronization therapy. An excellent correlation between the measured velocity and the true phantom motion (R = 0.90 for longitudinal velocity, R = 0.93 for circumferential velocity) was observed. Myocardial velocities were successfully measured in 17 healthy volunteers (11 male, six female; mean age, 27.5 years +/- 6.5 [standard deviation]) and 28 patients with heart failure (18 male, 10 female; mean age, 63.9 years +/- 15.0). Velocity values were significantly lower in the patients than in the volunteers. The time to peak velocity in the lateral wall of the patients, as compared with that in the volunteers, was delayed. Phase-contrast MR imaging can be combined with navigator-echo gating to measure three-directional myocardial tissue velocities in vivo.
Collapse
Affiliation(s)
- Jana G Delfino
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, 101 Woodruff Cir, Suite 2001, Atlanta, GA 30322, USA.
| | | | | | | | | | | |
Collapse
|
24
|
Hiller KH, Waller C, Haase A, Jakob PM. Magnetic resonance of mouse models of cardiac disease. Handb Exp Pharmacol 2008:245-57. [PMID: 18626605 DOI: 10.1007/978-3-540-77496-9_10] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
In recent years magnetic resonance imaging (MRI) has become the noninvasive standard for the quantitative evaluation of cardiac function, masses, and infarct size. Wall motion analysis is used to display myocardial dysfunction and microcirculatory deficits can be displayed by perfusion imaging and quantification of the myocardial regional blood volume. Magnetic resonance spectroscopy (MRS) also provides quantitative information on cardiac energetics and, in combination with MRI, insights into cardiac structure and function. The use of both techniques permits complementary data collection within the same experimental setup.Nevertheless, it should be mentioned that MR does not directly visualize genes or gene product expression but morphological or bioenergetical outcomes of gene expression instead. In conclusion, cardiac MR is a valuable tool applicable to mouse phenotyping and, also, can be applied to assess the effects of therapeutic agents. Thus, MR of mouse models of cardiac disease has great potential to substantially contribute to the understanding of the underlying pathomechanisms and can help to evaluate new therapy options.
Collapse
Affiliation(s)
- Karl-Heinz Hiller
- Physikalisches Institut, Universität Würzburg, 97074 Würzburg, Germany.
| | | | | | | |
Collapse
|
25
|
Chin BB, Metzler SD, Lemaire A, Curcio A, Vemulapalli S, Greer KL, Petry NA, Turkington TG, Coleman RE, Rockman H, Jaszczak RJ. Left ventricular functional assessment in mice: feasibility of high spatial and temporal resolution ECG-gated blood pool SPECT. Radiology 2007; 245:440-8. [PMID: 17940303 DOI: 10.1148/radiol.2452061973] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE To prospectively determine feasibility of evaluating murine left ventricular (LV) function with electrocardiographically (ECG)-gated blood pool single photon emission computed tomography (SPECT). MATERIALS AND METHODS All animal studies had institutional animal care and use committee approval. SPECT was performed with conventional time-binned acquisition (eight frames per ECG cycle) in normal mice (normal group A, n = 6) and mice with myocardial infarction (MI) (n = 8). To determine feasibility of high temporal resolution and rapid data acquisition, another group of normal mice (normal group B, n = 4) underwent imaging with conventional (eight-frame) time-binned and list-mode (LM) acquisitions. LM acquisitions were reconstructed with eight and 16 frames per ECG cycle and 10 minutes of data (short LM). SPECT images were assessed visually, and LV-to-lung background activity ratios were calculated. LV end-systolic and end-diastolic volumes were defined with a phase analysis and threshold method. LV ejection fraction (LVEF) was calculated from LV volumes and count-based methods (n = 18 mice). Fractional shortening (FS) at echocardiography defined MI dysfunction (mild MI: FS > or = 50%; severe MI: FS < 50%). Group means were compared for significant differences with analysis of variance. RESULTS ECG-gated blood pool SPECT demonstrated normal, concentric LV contraction in all normal mice (n = 10). LV-to-lung background ratio was more than 10:1 (range, 10.3-29.4; n = 18). Focal wall motion abnormalities were detected at SPECT both visually and with phase analysis in all mice with severe MI (n = 5). Mice with severe MI had significantly lower LVEF than normal group A mice (32% +/- 14 [standard deviation] vs 64% +/- 8%; P < .001). All mice with mild MI (n = 3) had normal contraction and LVEF. In paired acquisitions in normal group B mice, all reconstructions (n = 16) showed normal LV contraction. LVEF was not significantly different (P = .88) between time-binned (71% +/- 12), eight-frame LM (71% +/- 12), 16-frame LM (77% +/- 10), and short LM (73% +/- 14) reconstructions. CONCLUSION Murine LV functional assessment is feasible with high spatial and temporal resolution ECG-gated blood pool SPECT. LV dysfunction can be quantified and focal wall motion abnormalities detected in the MI model of heart failure.
Collapse
Affiliation(s)
- Bennett B Chin
- Department of Radiology, Duke University School of Medicine, Durham, NC 27710, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Li Y, Garson CD, Xu Y, Beyers RJ, Epstein FH, French BA, Hossack JA. Quantification and MRI validation of regional contractile dysfunction in mice post myocardial infarction using high resolution ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2007; 33:894-904. [PMID: 17434660 PMCID: PMC2136434 DOI: 10.1016/j.ultrasmedbio.2006.12.008] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2006] [Revised: 12/06/2006] [Accepted: 12/22/2006] [Indexed: 05/14/2023]
Abstract
A versatile, computationally efficient two-dimensional (2D) speckle-tracking method based on high resolution ultrasound imaging is proposed to quantify regional myocardial dysfunction in mice. Ultrasound scans were performed on the hearts of normal and post myocardial infarction (MI) mice with a Vevo770 scanner (VisualSonics, Toronto, Canada) operating at 30 MHz frequency. Regional myocardial motion was tracked using a 2D minimum sum of absolute differences (MSAD) block-matching algorithm. Motion analyses calculated from ultrasound images were compared with gold-standard analyses performed using small animal magnetic resonance imaging (MRI). The radial and circumferential components of strain were compared between ultrasound and MRI short axis views and promising correlations were obtained (r = 0.90 and r = 0.85 for radial and circumferential strain, respectively). Therefore, ultrasound imaging, followed by 2D image tracking, provides an effective, low cost, mobile method to quantify murine cardiac function accurately and reliably.
Collapse
Affiliation(s)
- Yinbo Li
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
| | - Christopher D. Garson
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
| | - Yaqin Xu
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
| | - Ronald J. Beyers
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
| | | | - Brent A. French
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
- Department of Radiology, University of Virginia (Charlottesville, VA, USA)
| | - John A. Hossack
- Department of Biomedical Engineering, University of Virginia (Charlottesville, VA, USA)
| |
Collapse
|
27
|
Abstract
Transgenic and knockout mice can be used to study the genes and basic mechanisms involved in heart disease, and have therefore assumed a central role in modern cardiac research. MRI and MRS techniques have recently been developed for mice that enable the quantitative or semi-quantitative in vivo assessment of cardiac anatomy, function, perfusion, infarction, Ca(2+) influx, and metabolism. With these techniques, the normal mouse heart has been shown to be well suited as a model of human cardiac disease. The roles of individual genes in normal cardiac physiology have recently been studied by MR, including the role of neuronal nitric oxide synthase in beta-adrenergic stimulation, the roles of the inducible nitric oxide synthase and myoglobin in function, dilation, and energetics, and the role of cardiac troponin I in contractility. Furthermore, with a mouse model of myocardial infarction, the roles of the angiotensin II type 2 receptor, xanthine oxidase inhibitors, blood coagulation factor XIII, and inducible nitric oxide synthase in post-infarct function and remodeling have been further elucidated. Non-invasive in vivo MRI and MRS in mice provide a unique and powerful means for phenotyping genetically engineered mice and can improve our understanding of the roles of specific genes and proteins in cardiac physiology and pathophysiology.
Collapse
Affiliation(s)
- Frederick H Epstein
- Departments of Radiology and Biomedical Engineering, and the Cardiovascular Research Center, University of Virginia, Charlottesville, VA 22908, USA.
| |
Collapse
|
28
|
Herold V, Mörchel P, Faber C, Rommel E, Haase A, Jakob PM. In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T. Magn Reson Med 2006; 55:1058-64. [PMID: 16596630 DOI: 10.1002/mrm.20866] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired at three different levels in the murine myocardium with an in-plane resolution of 98 mum, a slice thickness of 0.6 mm, and a temporal resolution of 6 ms. The applied PC-MRI method was validated with phantom experiments that confirmed the correctness of the method with deviations of <1.7%. Myocardial in-plane velocities between 0.5 cm/s and 2.2 cm/s were determined for the healthy murine myocardium. Through-plane velocities of 0.1-0.83 cm/s were measured. Velocity data was also used to calculate the myocardial twist angle during systole at different slices in the short-axis view.
Collapse
Affiliation(s)
- Volker Herold
- Department of Experimental Physics 5, University of Würzburg, Würzburg, Germany.
| | | | | | | | | | | |
Collapse
|
29
|
Nahrendorf M, Streif JU, Hiller KH, Hu K, Nordbeck P, Ritter O, Sosnovik D, Bauer L, Neubauer S, Jakob PM, Ertl G, Spindler M, Bauer WR. Multimodal functional cardiac MRI in creatine kinase-deficient mice reveals subtle abnormalities in myocardial perfusion and mechanics. Am J Physiol Heart Circ Physiol 2006; 290:H2516-21. [PMID: 16415075 DOI: 10.1152/ajpheart.01038.2005] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A decrease in the supply of ATP from the creatine kinase (CK) system is thought to contribute to the evolution of heart failure. However, previous studies on mice with a combined knockout of the mitochondrial and cytosolic CK (CK−/−) have not revealed overt left ventricular dysfunction. The aim of this study was to employ novel MRI techniques to measure maximal myocardial velocity ( Vmax) and myocardial perfusion and thus determine whether abnormalities in the myocardial phenotype existed in CK−/− mice, both at baseline and 4 wk after myocardial infarction (MI). As a result, myocardial hypertrophy was seen in all CK−/− mice, but ejection fraction (EF) remained normal. Vmax, however, was significantly reduced in the CK−/− mice [wild-type, 2.32 ± 0.09 vs. CK−/−, 1.43 ± 0.16 cm/s, P < 0.05; and wild-type MI, 1.53 ± 0.11 vs. CK−/− MI, 1.26 ± 0.11 cm/s, P = not significant (NS), P < 0.05 vs. baseline]. Myocardial perfusion was also lower in the CK−/− mice (wild-type, 6.68 ± 0.27 vs. CK−/−, 4.12 ± 0.63 ml/g·min, P < 0.05; and wild-type MI, 3.97 ± 0.65 vs. CK−/− MI, 3.71 ± 0.57 ml/g·min, P = NS, P < 0.05 vs. baseline), paralleled by a significantly reduced capillary density (histology). In conclusion, myocardial function in transgenic mice may appear normal when only gross indexes of performance such as EF are assessed. However, the use of a combination of novel MRI techniques to measure myocardial perfusion and mechanics allowed the abnormalities in the CK−/− phenotype to be detected. The myocardium in CK-deficient mice is characterized by reduced perfusion and reduced maximal contraction velocity, suggesting that the myocardial hypertrophy seen in these mice cannot fully compensate for the absence of the CK system.
Collapse
Affiliation(s)
- Matthias Nahrendorf
- Medizinische Klinik und Poliklinik 1, Universität Würzburg, Josef Schneider-Strasse 2, 97080 Würzburg, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Delfino JG, Bhasin M, Cole R, Eisner RL, Merlino J, Leon AR, Oshinski JN. Comparison of myocardial velocities obtained with magnetic resonance phase velocity mapping and tissue doppler imaging in normal subjects and patients with left ventricular dyssynchrony. J Magn Reson Imaging 2006; 24:304-11. [PMID: 16786564 DOI: 10.1002/jmri.20641] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To compare longitudinal myocardial velocity and time to peak longitudinal velocity obtained with magnetic resonance phase velocity mapping (MR-PVM) and tissue Doppler imaging (TDI), and to assess the reproducibility of each method. MATERIALS AND METHODS Longitudinal myocardial velocity was measured by TDI and MR-PVM in 10 normal volunteers and 10 patients with dyssynchrony. The reproducibility of MR-PVM and TDI was assessed on repeated measurements in the 10 normal volunteers. RESULTS MR and TDI measurements of longitudinal myocardial velocity correlated well (r = 0.86) in both normal subjects and patients with dyssynchrony. However, myocardial velocities measured with MR consistently exceeded velocities measured with TDI. MR and TDI agreed strongly in measuring the time to peak velocity (r = 0.97). The reproducibility of TDI and MR-PVM appeared similar in measuring peak velocities (13.1% vs. 11.0%, respectively; P = NS) and time to peak velocity (9.1% vs. 5.7%, respectively; P = NS). CONCLUSION Excellent correlation and reproducibility were observed between MR-PVM and TDI in measuring longitudinal myocardial velocity and time to peak velocity in both normal subjects and patients with dyssynchrony.
Collapse
Affiliation(s)
- Jana G Delfino
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA 30332, USA
| | | | | | | | | | | | | |
Collapse
|
31
|
Bishop J, Feintuch A, Bock NA, Nieman B, Dazai J, Davidson L, Henkelman RM. Retrospective gating for mouse cardiac MRI. Magn Reson Med 2006; 55:472-7. [PMID: 16450339 DOI: 10.1002/mrm.20794] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Cardiac MR imaging in small animals presents some difficulties due to shorter cardiac cycles and smaller dimensions than in human beings, but prospectively gated techniques have been successfully applied. As with human imaging, there may be certain applications in animal imaging for which retrospective gating is preferable to prospective gating. For example, cardiac imaging in multiple mice simultaneously is one such application. In this work we investigate the use of retrospective gating for cardiac imaging in a mouse. Using a three-dimensional imaging protocol, we show that image quality with retrospective gating is comparable to prospectively gated imaging. We conclude that retrospective gating is applicable for small animal cardiac MRI and show how it can be applied to the problem of cardiac MRI in multiple mice.
Collapse
Affiliation(s)
- Jonathan Bishop
- Mouse Imaging Centre, Hospital for Sick Children, Toronto, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
32
|
Wise RG, Al-Shafei AIM, Carpenter TA, Hall LD, Huang CLH. Simultaneous measurement of blood and myocardial velocity in the rat heart by phase contrast MRI using sparseq-space sampling. J Magn Reson Imaging 2005; 22:614-27. [PMID: 16193471 DOI: 10.1002/jmri.20423] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
PURPOSE To measure cardiac blood flow patterns and ventricular wall velocities through the cardiac cycle in anesthetized Wistar Kyoto (WKY) rats. MATERIALS AND METHODS A gradient-echo cine pulse sequence incorporating pulsed field gradients (PFGs) provided phase contrast (PC) motion encoding. We achieved a range of velocity sensitivity that was sufficient to measure simultaneously the large flow velocities within the cardiac chambers and aortic outflow tract (up to 70 cm s(-1) during systole), and the comparatively small velocities of the cardiac wall (0-3 cm s(-1)). A scheme of sparsely sampling q-space combined with a probability-based method of velocity calculation permitted such measurements along three orthogonal axes, and yielded velocity vector maps in all four chambers of the heart and the aorta, in both longitudinal and transverse sections, for up to 12 time-points in the cardiac cycle. RESULTS Left ventricular systole was associated with a symmetrical laminar flow pattern along the cardiac axis, with no appearance of turbulence. In contrast, blood showed a swirling motion within the right ventricle (RV) in the region of the pulmonary outflow tract. During left ventricular diastole a plume of blood entered the left ventricle (LV) from the left atrium. The ventricular flow patterns could also be correlated with measurements of left ventricular wall motion. The greatest velocities of the ventricular walls occurred in the transverse cardiac plane and were maximal during diastolic refilling. The cardiac wall motion in the longitudinal axis demonstrated a caudal-apical movement that may also contribute to diastolic refilling. CONCLUSION The successful measurements of blood and myocardial velocity during normal myocardial function may be extended to quantify pathological cardiac changes in animal models of human cardiac disease.
Collapse
Affiliation(s)
- Richard G Wise
- Department of Human Anatomy and Genetics, University of Oxford, Oxford, UK.
| | | | | | | | | |
Collapse
|
33
|
Prasad S, Henein MY. Novel Insights into LV Remodelling after Murine Myocardial Infarction by In vivo Magnetic Resonance Tissue Velocity Mapping. Int J Cardiovasc Imaging 2005; 21:565-7. [PMID: 16175448 DOI: 10.1007/s10554-005-0671-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
34
|
Heijman E, Strijkers GJ, Habets J, Janssen B, Nicolay K. Magnetic resonance imaging of regional cardiac function in the mouse. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2004; 17:170-8. [PMID: 15614514 DOI: 10.1007/s10334-004-0082-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2004] [Revised: 10/27/2004] [Accepted: 10/29/2004] [Indexed: 12/17/2022]
Abstract
In this paper we introduce an improved harmonic phase (HARP) analysis for complementary spatial modulation of magnetization (CSPAMM) tagging of the mouse left ventricular wall, which enables the determination of regional displacement fields with the same resolution as the corresponding CINE anatomical images. CINE MRI was used to measure global function, such as the ejection fraction. The method was tested on two healthy mouse hearts and two mouse hearts with a myocardial infarction, which was induced by a ligation of the left anterior descending coronary artery. We show that the regional displacement fields can be determined. The mean circumferential strain for the left ventricular wall of one of the healthy mice was -0.09 +/- 0.04 (mean +/- standard deviation), while for one of the infarcted mouse hearts strains of -0.02 +/- 0.02 and -0.10 +/- 0.03 were found in the infarcted and remote regions, respectively.
Collapse
Affiliation(s)
- E Heijman
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | | | | | | | | |
Collapse
|
35
|
Vallée JP, Ivancevic MK, Nguyen D, Morel DR, Jaconi M. Current status of cardiac MRI in small animals. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2004; 17:149-56. [PMID: 15605278 DOI: 10.1007/s10334-004-0066-4] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2004] [Revised: 08/27/2004] [Accepted: 09/15/2004] [Indexed: 10/26/2022]
Abstract
Cardiac magnetic resonance imaging (MRI) on small animals is possible but remains challenging and not well standardized. This publication aims to provide an overview of the current techniques, applications and challenges of cardiac MRI in small animals for researchers interested in moving into this field. Solutions have been developed to obtain a reliable cardiac trigger in both the rat and the mouse. Techniques to measure ventricular function and mass have been well validated and are used by several research groups. More advanced techniques like perfusion imaging, delayed enhancement or tag imaging are emerging. Regarding cardiac applications, not only coronary ischemic disease but several other pathologies or conditions including cardiopathies in transgenic animals have already benefited from these new developments. Therefore, cardiac MRI has a bright future for research in small animals.
Collapse
Affiliation(s)
- J-P Vallée
- Digital Imaging Unit, Radiology and Medical Informatics Department, Geneva University Hospitals, CH-1211, Geneva 14, Switzerland.
| | | | | | | | | |
Collapse
|
36
|
Jalife J, Berenfeld O. Molecular mechanisms and global dynamics of fibrillation: an integrative approach to the underlying basis of vortex-like reentry. J Theor Biol 2004; 230:475-87. [PMID: 15363670 DOI: 10.1016/j.jtbi.2004.02.024] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2003] [Revised: 01/29/2004] [Accepted: 02/20/2004] [Indexed: 11/16/2022]
Abstract
Art Winfree's scientific legacy has been particularly important to our laboratory whose major goal is to understand the mechanisms of ventricular fibrillation (VF). Here, we take an integrative approach to review recent studies on the manner in which nonlinear electrical waves organize to result in VF. We describe the contribution of specific potassium channel proteins and of the myocardial fiber structure to such organization. The discussion centers on data derived from a model of stable VF in the Langendorff-perfused guinea pig heart that demonstrates distinct patterns of organization in the left (LV) and right (RV) ventricles. Analysis of optical mapping data reveals that VF excitation frequencies are distributed throughout the ventricles in clearly demarcated domains. The highest frequency domains are found on the anterior wall of the LV at a location where sustained reentrant activity is present. The optical data suggest that a high frequency rotor that remains stationary in the LV is the mechanism that sustains VF in this model. Computer simulations predict that the inward rectifying potassium current (IK1) is an essential determinant of rotor stability and frequency, and patch-clamp results strongly suggest that the outward component of IK1 of cells in the LV is significantly larger than in the RV. Additional computer simulations and analytical procedures predict that the filaments of the reentrant activity (scroll waves) adopt a non-random configuration depending on fiber organization within the ventricular wall. Using the minimal principle we have concluded that filaments align with the trajectory of least resistance (i.e. the geodesic) between their endpoints. Overall, the data discussed have opened new and potentially exciting avenues of research on the possible role played by inward rectifier channels in the mechanism of VF, as well as the organization of its reentrant sources in three-dimensional cardiac muscle. Such an integrative approach may lead us toward an understanding of the molecular and structural basis of VF and hopefully to new preventative approaches.
Collapse
Affiliation(s)
- José Jalife
- Department of Pharmacology, Institute for Cardiovascular Research, SUNY Upstate Medical University, Syracuse, NY 13210, USA.
| | | |
Collapse
|
37
|
Gilson WD, Yang Z, French BA, Epstein FH. Measurement of myocardial mechanics in mice before and after infarction using multislice displacement-encoded MRI with 3D motion encoding. Am J Physiol Heart Circ Physiol 2004; 288:H1491-7. [PMID: 15513963 DOI: 10.1152/ajpheart.00632.2004] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Cardiac MRI is an accurate, noninvasive modality for assessing the structure and function of the murine heart. In addition to conventional imaging, MRI tissue tracking methods can quantify numerous aspects of myocardial mechanics, including intramyocardial displacement, strain, twist, and torsion. In the present study, we developed and applied a novel pulse sequence based on displacement-encoded imaging using stimulated echoes (DENSE) that achieves multislice coverage, high spatial resolution, and three-dimensional (3D) displacement encoding. With the use of this technique, myocardial mechanics of C57Bl/6 mice were measured at baseline and 1 day after experimental myocardial infarction. At baseline, the mean systolic transmural circumferential strain was -0.14 +/- 0.02 and the mean systolic radial strain was 0.30 +/- 0.05. Changes in circumferential and radial strains from the subepicardium to the subendocardium were detected at baseline (P < 0.05). One day after infarction, significantly reduced 3D displacements and strain were detected in infarcted and noninfarcted myocardium. Infarction also reduced normalized systolic torsion from its baseline value of 1.35 +/- 0.27 degrees /mm (R = 0.99) to 0.07 +/- 0.54 degrees /mm (R = 0.96, P < 0.05). DENSE MRI can assess the 3D myocardial mechanics of the murine heart in <1 h of scan time at 4.7 T and may be applied to studies of myocardial mechanics in genetically engineered mice.
Collapse
Affiliation(s)
- Wesley D Gilson
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22908, USA
| | | | | | | |
Collapse
|
38
|
Abstract
The purpose of this review is to provide an introduction to the rapidly expanding field of mouse magnetic resonance imaging (MRI). It is by no means meant to be all-inclusive but rather to provide a brief introduction to the basics of MRI theory, provide some insight into the basic experiments that can be performed in mice by using MRI, and bring to light some factors to consider when planning a mouse MRI experiment.
Collapse
Affiliation(s)
- Robia G Pautler
- Department of Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas 77030, USA.
| |
Collapse
|
39
|
Gilson WD, Yang Z, French BA, Epstein FH. Complementary displacement-encoded MRI for contrast-enhanced infarct detection and quantification of myocardial function in mice. Magn Reson Med 2004; 51:744-52. [PMID: 15065247 DOI: 10.1002/mrm.20003] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
MRI is emerging as an important modality for assessing myocardial function in transgenic and knockout mouse models of cardiovascular disease, including myocardial infarction (MI). Displacement encoding with stimulated echoes (DENSE) measures myocardial motion at high spatial resolution using phase-reconstructed images. The current DENSE technique uses inversion recovery (IR) to suppress T(1)-relaxation artifacts; however, IR is ill-suited for contrast-enhanced infarct imaging in the heart, where multiple T(1) values are observed. We have developed a modified DENSE method employing complementary acquisitions for T(1)-independent artifact suppression. With this technique, displacement and strain are measured in phase-reconstructed images, and contrast-enhanced regions of infarction are depicted in perfectly coregistered magnitude-reconstructed images. The displacement measurements and T(1)-weighted image contrast were validated with the use of a rotating phantom. Modified DENSE was performed in mice (N = 9) before and after MI. Circumferential (E(cc)) and radial (E(rr)) strain were measured, and contrast-enhanced infarcted myocardium was detected by DENSE. At baseline, E(cc) was -0.16 +/- 0.01 and E(rr) was 0.39 +/- 0.07. After MI, E(cc) was 0.04 +/- 0.02 and E(rr) was 0.03 +/- 0.04 in infarcted regions, whereas E(cc) was -0.12 +/- 0.02 and E(rr) was 0.38 +/- 0.09 in noninfarcted regions. In vivo E(cc) as determined by DENSE correlated well with E(cc) obtained by conventional tag analysis (R = 0.90).
Collapse
Affiliation(s)
- Wesley D Gilson
- Department of Radiology, University of Virginia Health System, Charlottesville, Virginia 22908, USA
| | | | | | | |
Collapse
|