Uzun D, Yildirim DK, Bruce CG, Halaby RN, Jaimes A, Potersnak A, Ramasawmy R, Campbell-Washburn A, Lederman RJ, Kocaturk O. Interventional device tracking under MRI via alternating current controlled inhomogeneities. Magn Reson Med 2024; 92:346-360. [PMID: 38394163 PMCID: PMC11055668 DOI: 10.1002/mrm.30031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 02/25/2024]
Abstract
PURPOSE To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.
Collapse
Affiliation(s)
- Dogangun Uzun
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| | - Dursun Korel Yildirim
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Christopher G. Bruce
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rim N. Halaby
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Andi Jaimes
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Amanda Potersnak
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Adrienne Campbell-Washburn
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Robert J. Lederman
- Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, MD, USA
| | - Ozgur Kocaturk
- Institute of Biomedical Engineering, Bogazici University, Istanbul, Turkey
| |
Collapse
|
2
|
Roth BJ. Can MRI Be Used as a Sensor to Record Neural Activity? SENSORS (BASEL, SWITZERLAND) 2023; 23:1337. [PMID: 36772381 PMCID: PMC9918955 DOI: 10.3390/s23031337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/17/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
Magnetic resonance provides exquisite anatomical images and functional MRI monitors physiological activity by recording blood oxygenation. This review attempts to answer the following question: Can MRI be used as a sensor to directly record neural behavior? It considers MRI sensing of electrical activity in the heart and in peripheral nerves before turning to the central topic: recording of brain activity. The primary hypothesis is that bioelectric current produced by a nerve or muscle creates a magnetic field that influences the magnetic resonance signal, although other mechanisms for detection are also considered. Recent studies have provided evidence that using MRI to sense neural activity is possible under ideal conditions. Whether it can be used routinely to provide functional information about brain processes in people remains an open question. The review concludes with a survey of artificial intelligence techniques that have been applied to functional MRI and may be appropriate for MRI sensing of neural activity.
Collapse
Affiliation(s)
- Bradley J Roth
- Department of Physics, Oakland University, Rochester, MI 48309, USA
| |
Collapse
|
3
|
Benders S, Mohammadi M, Ganter MJ, Klug CA, Jerschow A. Mapping oscillating magnetic fields around rechargeable batteries. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 319:106811. [PMID: 32920429 DOI: 10.1016/j.jmr.2020.106811] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/14/2020] [Accepted: 08/20/2020] [Indexed: 06/11/2023]
Abstract
Power storage devices such as batteries are a crucial part of modern technology. The development and use of batteries has accelerated in the past decades, yet there are only a few techniques that allow gathering vital information from battery cells in a nonivasive fashion. A widely used technique to investigate batteries is electrical impedance spectroscopy (EIS), which provides information on how the impedance of a cell changes as a function of the frequency of applied alternating currents. Building on recent developments of inside-out MRI (ioMRI), a technique is presented here which produces spatially-resolved maps of the oscillating magnetic fields originating from the alternating electrical currents distributed within a cell. The technique works by using an MRI pulse sequence synchronized with a gated alternating current applied to the cell terminals. The approach is benchmarked with a current-carrying wire coil, and demonstrated with commercial and prototype lithium-ion cells. Marked changes in the fields are observed for different cell types.
Collapse
Affiliation(s)
- Stefan Benders
- Department of Chemistry, New York University, New York, United States
| | | | - Matthew J Ganter
- Battery Prototyping Center, Rochester Institute of Technology, United States
| | - Christopher A Klug
- United States Naval Research Laboratory, District of Columbia, United States; Department of Chemistry, New York University, New York, United States
| | - Alexej Jerschow
- Department of Chemistry, New York University, New York, United States.
| |
Collapse
|
4
|
Kim KH, Heo HI, Park SH. Detection of fast oscillating magnetic fields using dynamic multiple TR imaging and Fourier analysis. PLoS One 2018; 13:e0189916. [PMID: 29320580 PMCID: PMC5761850 DOI: 10.1371/journal.pone.0189916] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 12/04/2017] [Indexed: 11/18/2022] Open
Abstract
Neuronal oscillations produce oscillating magnetic fields. There have been trials to detect neuronal oscillations using MRI, but the detectability in in vivo is still in debate. Major obstacles to detecting neuronal oscillations are (i) weak amplitudes, (ii) fast oscillations, which are faster than MRI temporal resolution, and (iii) random frequencies and on/off intervals. In this study, we proposed a new approach for direct detection of weak and fast oscillating magnetic fields. The approach consists of (i) dynamic acquisitions using multiple times to repeats (TRs) and (ii) an expanded frequency spectral analysis. Gradient echo echo-planar imaging was used to test the feasibility of the proposed approach with a phantom generating oscillating magnetic fields with various frequencies and amplitudes and random on/off intervals. The results showed that the proposed approach could precisely detect the weak and fast oscillating magnetic fields with random frequencies and on/off intervals. Complex and phase spectra showed reliable signals, while no meaningful signals were observed in magnitude spectra. A two-TR approach provided an absolute frequency spectrum above Nyquist sampling frequency pixel by pixel with no a priori target frequency information. The proposed dynamic multiple-TR imaging and Fourier analysis are promising for direct detection of neuronal oscillations and potentially applicable to any pulse sequences.
Collapse
Affiliation(s)
- Ki Hwan Kim
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Hyo-Im Heo
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
| | - Sung-Hong Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea
- * E-mail:
| |
Collapse
|
5
|
Sundaram P, Nummenmaa A, Wells W, Orbach D, Orringer D, Mulkern R, Okada Y. Direct neural current imaging in an intact cerebellum with magnetic resonance imaging. Neuroimage 2016; 132:477-490. [PMID: 26899788 DOI: 10.1016/j.neuroimage.2016.01.059] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 11/10/2015] [Accepted: 01/26/2016] [Indexed: 10/22/2022] Open
Abstract
The ability to detect neuronal currents with high spatiotemporal resolution using magnetic resonance imaging (MRI) is important for studying human brain function in both health and disease. While significant progress has been made, we still lack evidence showing that it is possible to measure an MR signal time-locked to neuronal currents with a temporal waveform matching concurrently recorded local field potentials (LFPs). Also lacking is evidence that such MR data can be used to image current distribution in active tissue. Since these two results are lacking even in vitro, we obtained these data in an intact isolated whole cerebellum of turtle during slow neuronal activity mediated by metabotropic glutamate receptors using a gradient-echo EPI sequence (TR=100ms) at 4.7T. Our results show that it is possible (1) to reliably detect an MR phase shift time course matching that of the concurrently measured LFP evoked by stimulation of a cerebellar peduncle, (2) to detect the signal in single voxels of 0.1mm(3), (3) to determine the spatial phase map matching the magnetic field distribution predicted by the LFP map, (4) to estimate the distribution of neuronal current in the active tissue from a group-average phase map, and (5) to provide a quantitatively accurate theoretical account of the measured phase shifts. The peak values of the detected MR phase shifts were 0.27-0.37°, corresponding to local magnetic field changes of 0.67-0.93nT (for TE=26ms). Our work provides an empirical basis for future extensions to in vivo imaging of neuronal currents.
Collapse
Affiliation(s)
- Padmavathi Sundaram
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Aapo Nummenmaa
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.
| | - William Wells
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Darren Orbach
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Daniel Orringer
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Robert Mulkern
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Yoshio Okada
- Department of Newborn Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA 02215, USA.
| |
Collapse
|
6
|
Eibofner F, Martirosian P, Würslin C, Graf H, Syha R, Clasen S. Technical Note: MR-visualization of interventional devices using transient field alterations and balanced steady-state free precession imaging. Med Phys 2015; 42:6558-63. [PMID: 26520746 DOI: 10.1118/1.4932629] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In interventional magnetic resonance imaging, instruments can be equipped with conducting wires for visualization by current application. The potential of sequence triggered application of transient direct currents in balanced steady-state free precession (bSSFP) imaging is demonstrated. METHODS A conductor and a modified catheter were examined in water phantoms and in an ex vivo porcine liver. The current was switched by a trigger pulse in the bSSFP sequence in an interval between radiofrequency pulse and signal acquisition. Magnitude and phase images were recorded. Regions with transient field alterations were evaluated by a postprocessing algorithm. A phase mask was computed and overlaid with the magnitude image. RESULTS Transient field alterations caused continuous phase shifts, which were separated by the postprocessing algorithm from phase jumps due to persistent field alterations. The overlaid images revealed the position of the conductor. The modified catheter generated visible phase offset in all orientations toward the static magnetic field and could be unambiguously localized in the ex vivo porcine liver. CONCLUSIONS The application of a sequence triggered, direct current in combination with phase imaging allows conspicuous localization of interventional devices with a bSSFP sequence.
Collapse
Affiliation(s)
- Frank Eibofner
- Section on Experimental Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| | - Petros Martirosian
- Section on Experimental Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| | - Christian Würslin
- Section on Experimental Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| | - Hansjörg Graf
- Section on Experimental Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| | - Roland Syha
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| | - Stephan Clasen
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen D-72076, Germany
| |
Collapse
|
7
|
Balasubramanian M, Mulkern RV, Wells WM, Sundaram P, Orbach DB. Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow. Magn Reson Med 2014; 74:1145-55. [PMID: 25273917 DOI: 10.1002/mrm.25445] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Revised: 07/25/2014] [Accepted: 08/15/2014] [Indexed: 11/06/2022]
Abstract
PURPOSE Reliably detecting MRI signals in the brain that are more tightly coupled to neural activity than blood-oxygen-level-dependent fMRI signals could not only prove valuable for basic scientific research but could also enhance clinical applications such as epilepsy presurgical mapping. This endeavor will likely benefit from an improved understanding of the behavior of ionic currents, the mediators of neural activity, in the presence of the strong magnetic fields that are typical of modern-day MRI scanners. THEORY Of the various mechanisms that have been proposed to explain the behavior of ionic volume currents in a magnetic field, only one-magnetohydrodynamic flow-predicts a slow evolution of signals, on the order of a minute for normal saline in a typical MRI scanner. METHODS This prediction was tested by scanning a volume-current phantom containing normal saline with gradient-echo-planar imaging at 3 T. RESULTS Greater signal changes were observed in the phase of the images than in the magnitude, with the changes evolving on the order of a minute. CONCLUSION These results provide experimental support for the MHD flow hypothesis. Furthermore, MHD-driven cerebrospinal fluid flow could provide a novel fMRI contrast mechanism.
Collapse
Affiliation(s)
- Mukund Balasubramanian
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Robert V Mulkern
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - William M Wells
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Padmavathi Sundaram
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Darren B Orbach
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
8
|
Buračas GT, Jung Y, Lee J, Buxton RB, Wong EC, Liu TT. On multiple alternating steady states induced by periodic spin phase perturbation waveforms. Magn Reson Med 2011; 67:1412-8. [PMID: 21826730 DOI: 10.1002/mrm.23105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 05/29/2011] [Accepted: 06/25/2011] [Indexed: 11/09/2022]
Abstract
Direct measurement of neural currents by means of MRI can potentially open a high temporal resolution (10-100 ms) window applicable for monitoring dynamics of neuronal activity without loss of the high spatial resolution afforded by MRI. Previously, we have shown that the alternating balanced steady state imaging affords high sensitivity to weak periodic currents owing to its amplification of periodic spin phase perturbations. This technique, however, requires precise synchronization of such perturbations to the radiofrequency pulses. Herein, we extend alternating balanced steady state imaging to multiple balanced alternating steady states for estimation of neural current waveforms. Simulations and phantom experiments show that the off-resonance profile of the multiple alternating steady state signal carries information about the frequency content of driving waveforms. In addition, the method is less sensitive than alternating balanced steady state to precise waveform timing relative to radiofrequency pulses. Thus, multiple alternating steady state technique is potentially applicable to MR imaging of the waveforms of periodic neuronal activity.
Collapse
Affiliation(s)
- Giedrius T Buračas
- Center for Functional MRI, Department of Radiology, University of California, San Diego, La Jolla, California 92037, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Miller KL, Tijssen RHN, Stikov N, Okell TW. Steady-state MRI: methods for neuroimaging. ACTA ACUST UNITED AC 2011. [DOI: 10.2217/iim.10.66] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
10
|
Wojtczyk H, Graf H, Martirosian P, Ballweg V, Kraiger M, Pintaske J, Schick F. Quantification of direct current in electrically active implants using MRI methods. Z Med Phys 2011; 21:135-46. [PMID: 21277177 DOI: 10.1016/j.zemedi.2010.12.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2010] [Revised: 11/30/2010] [Accepted: 12/01/2010] [Indexed: 11/19/2022]
Abstract
The aim of this study was to evaluate a variety of phase- and magnitude-based MRI methods at 1.5 T and 3 T regarding their sensitivity and accuracy with respect to the quantification of electrical direct current via the induced magnetic field inhomogeneity. For this, a phantom was constructed which was specially designed to reduce RF effects and which provided a one-dimensional electrical direct current in a thin copper conductor perpendicular to the static magnetic field of the scanner. The current was varied between 4 mA and 472 mA. The analysis of FLASH phase images as well as trueFISP and MAGSUS images revealed that the accuracy of the MR current measurement depended on the method and the field strength: the mean of the absolute deviations of the measured current values from the adjusted current values varied between 9% and 21%. The phase measurement with a FLASH sequence was found to be more sensitive than the trueFISP and MAGSUS measurements. In FLASH magnitude images as well as in images of spin echo sequences with on- and off-resonant frequency selective saturation pulses the extension of the artifact increased with the electrical current. MRI methods for the quantification of electrical direct current might e.g. play a role in functional testing of electrically active devices in the human body in terms of measuring the present current. One-dimensional electrical direct current in a thin, straight conductor could also be applied to the visualization of instruments in interventional MRI procedures. Currents below 100 mA would be sufficient to create distinct artifacts, at least under simplified conditions (homogeneous background etc.).
Collapse
Affiliation(s)
- Hanne Wojtczyk
- Section on Experimental Radiology, Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Hoppe-Seyler-Straße, Germany.
| | | | | | | | | | | | | |
Collapse
|
11
|
Lee J, Fukunaga M, Duyn JH. Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession. Neuroimage 2010; 54:2779-88. [PMID: 21040793 DOI: 10.1016/j.neuroimage.2010.10.071] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2010] [Revised: 10/20/2010] [Accepted: 10/23/2010] [Indexed: 11/29/2022] Open
Abstract
Recent MRI studies have exploited subtle magnetic susceptibility differences between brain tissues to improve anatomical contrast and resolution. These susceptibility differences lead to resonance frequency shifts which can be visualized by reconstructing the signal phase in conventional gradient echo (GRE) acquisition techniques. In this work, a method is proposed to improve the contrast to noise ratio per unit time (CNR efficiency) of anatomical MRI based on resonance frequency contrast. The method, based on the balanced steady-state free precession (bSSFP) MRI acquisition technique, was evaluated in its ability to generate contrast between gray and white matter in human brain at 3T and 7T. The results show substantially improved CNR efficiency of bSSFP phase images (2.85±0.21 times at 3 T and 1.71±0.11 times at 7 T) compared to the GRE data in a limited spatial area. This limited spatial coverage is attributed to the sensitivity of bSSFP to macroscopic B(0) inhomogeneities. With this CNR improvement, high resolution bSSFP phase images (resolution=0.3×0.3×2 mm(3), acquisition time=10min) acquired at 3T had sufficient CNR to allow the visualization of cortical laminar structures in invivo human primary visual cortex. Practical application of the proposed method may require improvement of B(0) homogeneity and stability by additional preparatory scans and/or compensation schemes such as respiration and drift compensation. Without these additions, the CNR benefits of the method may be limited to studies at low field or limited regions of interest.
Collapse
Affiliation(s)
- Jongho Lee
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD 20892-1065, USA.
| | | | | |
Collapse
|
12
|
Abstract
Functional MRI has become an important tool of researchers and clinicians who seek to understand patterns of neuronal activation that accompany sensory and cognitive processes. However, the interpretation of fMRI images rests on assumptions about the relationship between neuronal firing and hemodynamic response that are not firmly grounded in rigorous theory or experimental evidence. Further, the blood-oxygen-level-dependent effect, which correlates an MRI observable to neuronal firing, evolves over a period that is 2 orders of magnitude longer than the underlying processes that are thought to cause it. Here, we instead demonstrate experiments to directly image oscillating currents by MRI. The approach rests on a resonant interaction between an applied rf field and an oscillating magnetic field in the sample and, as such, permits quantitative, frequency-selective measurements of current density without spatial or temporal cancellation. We apply this method in a current loop phantom, mapping its magnetic field and achieving a detection sensitivity near the threshold required for the detection of neuronal currents. Because the contrast mechanism is under spectroscopic control, we are able to demonstrate how ramped and phase-modulated spin-lock radiation can enhance the sensitivity and robustness of the experiment. We further demonstrate the combination of these methods with remote detection, a technique in which the encoding and detection of an MRI experiment are separated by sample flow or translation. We illustrate that remotely detected MRI permits the measurement of currents in small volumes of flowing water with high sensitivity and spatial resolution.
Collapse
|
13
|
Luo Q, Lu H, Lu H, Yang Y, Gao JH. Comparison of visually evoked local field potentials in isolated turtle brain: Patterned versus blank stimulation. J Neurosci Methods 2010; 187:26-32. [PMID: 20034520 DOI: 10.1016/j.jneumeth.2009.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2009] [Revised: 12/09/2009] [Accepted: 12/11/2009] [Indexed: 11/17/2022]
Affiliation(s)
- Qingfei Luo
- Department of Radiology, Brain Research Imaging Center, The University of Chicago, Chicago, IL 60637, United States
| | | | | | | | | |
Collapse
|
14
|
|
15
|
Lee J, Hirano Y, Fukunaga M, Silva AC, Duyn JH. On the contribution of deoxy-hemoglobin to MRI gray-white matter phase contrast at high field. Neuroimage 2009; 49:193-8. [PMID: 19619663 DOI: 10.1016/j.neuroimage.2009.07.017] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2009] [Revised: 06/30/2009] [Accepted: 07/13/2009] [Indexed: 11/15/2022] Open
Abstract
High field (> or =7 T) MRI studies based on signal phase have been used to improve visualization of the fine structure of the brain, most notably the major white matter fiber bundles, the gray-white matter subdivision, and the laminar cortical architecture. The observed contrast has been attributed in part to local variations in magnetic susceptibility arising from iron in storage proteins and tissue lipid. Another contribution could come from the paramagnetic blood constituent deoxy-hemoglobin, the tissue concentration of which may vary through local variations in vascular density. To investigate this possibility, we examined phase contrast between gray and white matter in rats after intravenous administration of a superparamagnetic contrast agent at various dosages. At the maximum dosage (3 mg Fe/kg), which resulted in an estimated paramagnetic susceptibility shift 4-8 times larger than deoxy-hemoglobin, we observed a negligible increase in phase contrast between gray and white matter. This result suggests that endogenous deoxy-hemoglobin has no significant contribution to phase contrast between gray and white matter.
Collapse
Affiliation(s)
- Jongho Lee
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD 20892, USA.
| | | | | | | | | |
Collapse
|
16
|
Luo Q, Lu H, Lu H, Senseman D, Worsley K, Yang Y, Gao JH. Physiologically evoked neuronal current MRI in a bloodless turtle brain: detectable or not? Neuroimage 2009; 47:1268-76. [PMID: 19539040 DOI: 10.1016/j.neuroimage.2009.06.017] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2009] [Revised: 05/29/2009] [Accepted: 06/05/2009] [Indexed: 10/20/2022] Open
Abstract
Contradictory reports regarding the detection of neuronal currents have left the feasibility of neuronal current MRI (ncMRI) an open question. Most previous ncMRI studies in human subjects are suspect due to their inability to separate or eliminate hemodynamic effects. In this study, we used a bloodless turtle brain preparation that eliminates hemodynamic effects, to explore the feasibility of detecting visually-evoked ncMRI signals at 9.4 T. Intact turtle brains, with eyes attached, were dissected from the cranium and placed in artificial cerebral spinal fluid. Light flashes were delivered to the eyes to evoke neuronal activity. Local field potential (LFP) and MRI signals were measured in an interleaved fashion. Robust visually-evoked LFP signals were observed in turtle brains, but no significant signal changes synchronized with neuronal currents were found in the ncMRI images. In this study, detection thresholds of 0.1% and 0.1 degrees were set for MRI magnitude and phase signal changes, respectively. The absence of significant signal changes in the MRI images suggests that visually-evoked ncMRI signals in the turtle brain are below these detectable levels.
Collapse
Affiliation(s)
- Qingfei Luo
- Brain Research Imaging Center and Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
| | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
The rapid advancement of neuroimaging methodology and its growing availability has transformed neuroscience research. The answers to many questions that we ask about how the brain is organized depend on the quality of data that we are able to obtain about the locations, dynamics, fluctuations, magnitudes, and types of brain activity and structural changes. In this review an attempt is made to take a snapshot of the cutting edge of a small component of the very rapidly evolving field of neuroimaging. For each area covered, a brief context is provided along with a summary of a few of the current developments and issues. Then, several outstanding papers, published in the past year or so, are described, providing an example of the directions in which each area is progressing. The areas covered include functional magnetic resonance imaging (fMRI), voxel-based morphometry (VBM), diffusion tensor imaging (DTI), electroencephalography (EEG), magnetoencephalography (MEG), optical imaging, and positron emission tomography (PET). More detail is included on fMRI; its subsections include fMRI interpretation, new fMRI contrasts, MRI technology, MRI paradigms and processing, and endogenous oscillations in fMRI.
Collapse
Affiliation(s)
- Peter A Bandettini
- Section on Functional Imaging Methods & Functional MRI Core Facility, National Institute of Mental Health, Bethesda, Maryland 20894, USA.
| |
Collapse
|
18
|
Chow LS, Dagens A, Fu Y, Cook GG, Paley MNJ. Comparison of BOLD and direct-MR neuronal detection (DND) in the human visual cortex at 3T. Magn Reson Med 2009; 60:1147-54. [PMID: 18956466 DOI: 10.1002/mrm.21753] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Direct-MR neuronal detection (DND) of transient magnetic fields has recently been investigated as a novel imaging alternative to the conventional BOLD functional MRI (fMRI) technique. However, there remain controversial issues and debate surrounding this methodology, and this study attempts clarification by comparing BOLD responses in the human visual system with those of DND. BOLD relies on indirectly measuring blood oxygenation and flow changes as a result of neuronal activity, whereas the putative DND method is based on the hypothesis that the components of the in vivo neuronal magnetic fields, which lie parallel to the B(0) field, can potentially modulate the MR signal, thus providing a means of direct detection of nerve impulses. Block paradigms of checkerboard patterns were used for visual stimulation in both DND and BOLD experiments, allowing detection based on different frequency responses. This study shows colocalization of some voxels with slow BOLD responses and putative fast DND responses using General Linear Model (GLM) analysis. Frequency spectra for the activated voxel cluster are also shown for both stimulated and control data. The mean percentage signal change for the DND responses is 0.2%, corresponding to a predicted neuronal field of 0.14 nT.
Collapse
Affiliation(s)
- Li Sze Chow
- Section of Academic Radiology, University of Sheffield, Sheffield, UK
| | | | | | | | | |
Collapse
|