Schäper J, Bieri O. Myelin water imaging at 0.55 T using a multigradient-echo sequence. Magn Reson Med 2024; 91:1043-1056. [PMID: 38010053 DOI: 10.1002/mrm.29949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/19/2023] [Accepted: 11/12/2023] [Indexed: 11/29/2023]
Abstract
PURPOSE To investigate the prospects of a multigradient-echo (mGRE) acquisition for in vivo myelin water imaging at 0.55 T. METHODS Scans were performed on the brain of four healthy volunteers at 0.55 and 3 T, using a 3D mGRE sequence. The myelin water fraction (MWF) was calculated for both field strengths using a nonnegative least squares (NNLS) algorithm, implemented in the qMRLab suite. The quality of these maps as well as single-voxel fits were compared visually for 0.55 and 3 T. RESULTS The obtained MWF values at 0.55 T are consistent with previously reported ones at higher field strengths. The MWF maps are a considerable improvement over the ones at 3 T. Example fits show that 0.55 T data is better described by an exponential model than 3 T data, making the assumed multi-exponential model of the NNLS algorithm more accurate. CONCLUSION This first assessment shows that mGRE myelin water imaging at 0.55 T is feasible and has the potential to yield better results than at higher fields.
Collapse
Affiliation(s)
- Jessica Schäper
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
- Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland
| | - Oliver Bieri
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
- Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, Switzerland
| |
Collapse
|
2
|
Michell-Robinson MA, Watt KEN, Grouza V, Macintosh J, Pinard M, Tuznik M, Chen X, Darbelli L, Wu CL, Perrier S, Chitsaz D, Uccelli NA, Liu H, Cox TC, Müller CW, Kennedy TE, Coulombe B, Rudko DA, Trainor PA, Bernard G. Hypomyelination, hypodontia and craniofacial abnormalities in a Polr3b mouse model of leukodystrophy. Brain 2023; 146:5070-5085. [PMID: 37635302 PMCID: PMC10690025 DOI: 10.1093/brain/awad249] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 06/23/2023] [Accepted: 07/06/2023] [Indexed: 08/29/2023] Open
Abstract
RNA polymerase III (Pol III)-related hypomyelinating leukodystrophy (POLR3-HLD), also known as 4H leukodystrophy, is a severe neurodegenerative disease characterized by the cardinal features of hypomyelination, hypodontia and hypogonadotropic hypogonadism. POLR3-HLD is caused by biallelic pathogenic variants in genes encoding Pol III subunits. While approximately half of all patients carry mutations in POLR3B encoding the RNA polymerase III subunit B, there is no in vivo model of leukodystrophy based on mutation of this Pol III subunit. Here, we determined the impact of POLR3BΔ10 (Δ10) on Pol III in human cells and developed and characterized an inducible/conditional mouse model of leukodystrophy using the orthologous Δ10 mutation in mice. The molecular mechanism of Pol III dysfunction was determined in human cells by affinity purification-mass spectrometry and western blot. Postnatal induction with tamoxifen induced expression of the orthologous Δ10 hypomorph in triple transgenic Pdgfrα-Cre/ERT; R26-Stopfl-EYFP; Polr3bfl mice. CNS and non-CNS features were characterized using a variety of techniques including microCT, ex vivo MRI, immunofluorescence, immunohistochemistry, spectral confocal reflectance microscopy and western blot. Lineage tracing and time series analysis of oligodendrocyte subpopulation dynamics based on co-labelling with lineage-specific and/or proliferation markers were performed. Proteomics suggested that Δ10 causes a Pol III assembly defect, while western blots demonstrated reduced POLR3BΔ10 expression in the cytoplasm and nucleus in human cells. In mice, postnatal Pdgfrα-dependent expression of the orthologous murine mutant protein resulted in recessive phenotypes including severe hypomyelination leading to ataxia, tremor, seizures and limited survival, as well as hypodontia and craniofacial abnormalities. Hypomyelination was confirmed and characterized using classic methods to quantify myelin components such as myelin basic protein and lipids, results which agreed with those produced using modern methods to quantify myelin based on the physical properties of myelin membranes. Lineage tracing uncovered the underlying mechanism for the hypomyelinating phenotype: defective oligodendrocyte precursor proliferation and differentiation resulted in a failure to produce an adequate number of mature oligodendrocytes during postnatal myelinogenesis. In summary, we characterized the Polr3bΔ10 mutation and developed an animal model that recapitulates features of POLR3-HLD caused by POLR3B mutations, shedding light on disease pathogenesis, and opening the door to the development of therapeutic interventions.
Collapse
Affiliation(s)
- Mackenzie A Michell-Robinson
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Kristin E N Watt
- Stowers Institute for Medical Research, Kansas City, MO 64110, USA
| | - Vladimir Grouza
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC H3A 2B4, Canada
| | - Julia Macintosh
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Maxime Pinard
- Translational Proteomics Research Unit, Montreal Clinical Research Institute, Montréal, QC H2W 1R7, Canada
| | - Marius Tuznik
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC H3A 2B4, Canada
| | - Xiaoru Chen
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Lama Darbelli
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Chia-Lun Wu
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Stefanie Perrier
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| | - Daryan Chitsaz
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
| | - Nonthué A Uccelli
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
| | - Hanwen Liu
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC H3A 2B4, Canada
| | - Timothy C Cox
- Department of Oral and Craniofacial Sciences, School of Dentistry, and Pediatrics, School of Medicine, University of Missouri – Kansas City, Kansas City, MO 64108, USA
| | - Christoph W Müller
- Structural and Computational Biology Unit, European Molecular Biology Laboratory (EMBL), 69117 Heidelberg, Germany
| | - Timothy E Kennedy
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
| | - Benoit Coulombe
- Translational Proteomics Research Unit, Montreal Clinical Research Institute, Montréal, QC H2W 1R7, Canada
- Department of Biochemistry and Molecular Medicine, University of Montréal, Montréal, QC H3C 3J7, Canada
| | - David A Rudko
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC H3A 2B4, Canada
- Department of Biomedical Engineering, McGill University, Montréal, QC H3A 2B4, Canada
| | - Paul A Trainor
- Stowers Institute for Medical Research, Kansas City, MO 64110, USA
- Department of Anatomy and Cell Biology, The University of Kansas School of Medicine, Kansas City, KS 66160, USA
| | - Geneviève Bernard
- Department of Neurology and Neurosurgery, McGill University, Montréal, QC H3A 1A1, Canada
- Child Health and Human Development Program, Research Institute of the McGill University Health Centre, Montréal, QC H4A 3J1, Canada
- Department of Pediatrics, McGill University, Montréal, QC H4A 3J1, Canada
- Department of Human Genetics, McGill University, Montréal, QC H4A 0C7, Canada
- Department of Specialized Medicine, Division of Medical Genetics, Montreal Children’s Hospital and McGill University Health Centre, Montréal, QC H4A 3J1, Canada
| |
Collapse
|
3
|
Ostenson J, Robison RK, Brittain EL, Damon BM. Feasibility of joint mapping of triglyceride saturation and water longitudinal relaxation in a single breath hold applied to high fat-fraction adipose depots in the periclavicular anatomy. Magn Reson Imaging 2023; 99:58-66. [PMID: 36764629 PMCID: PMC10088071 DOI: 10.1016/j.mri.2023.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/27/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023]
Abstract
INTRODUCTION Simultaneous mapping of triglyceride (TAG) saturation and tissue water relaxation may improve the characterization of the structure and function of anatomies with significant adipose tissue. While several groups have demonstrated in vivo TAG saturation imaging using MRI, joint mapping of relaxation and TAG saturation is understudied. Such mappings may avoid bias from physiological motion, if they can be done within a single breath-hold, and also account for static and applied magnetic field heterogeneity. METHODS We propose a transient-state/MR fingerprinting single breath-hold sequence at 3 T, a low-rank reconstruction, and a parameter estimation pipeline that jointly estimates the number of double bonds (NDB), number of methylene interrupted double bonds (NMIDB), and tissue water T1, while accounting for non-ideal radiofrequency transmit scaling and off-resonance effects. We test the proposed method in simulations, in phantom against MR spectroscopy (MRS), and in vivo regions in and around high fat fraction (FF) periclavicular adipose tissue. Partial volume and multi-peak transverse relaxation effects are explored. RESULTS The simulation results demonstrate accurate NDB, NMIDB, and water T1 estimates across a range of NDB, NMIDB, and T1 values. In phantoms, the proposed method's estimates of NDB and NMIDB correlate with those from MR spectroscopy (Pearson correlation ≥0.98), while the water T1 estimates are concordant with a standard phantom. The NDB and NMIDB are sensitive to partial volumes of water, showing increasing bias at FF < 40%. This bias is found to be due to noise and transverse relaxation effects. The in vivo periclavicular adipose tissue has high FF (>90%). The adipose tissue NDB and NMIDB, and muscle T1 estimates are comparable to those reported in the literature. CONCLUSION Robust estimation of NDB, NMIDB at high FF and water T1 across a broad range of FFs are feasible using the proposed methods. Further reduction of noise and model bias are needed to employ the proposed technique in low FF anatomies and pathologies.
Collapse
Affiliation(s)
- Jason Ostenson
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States of America; Dept. of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States of America.
| | - Ryan K Robison
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, United States of America; Philips, Gainesville, FL, United States of America
| | - Evan L Brittain
- Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, TN, United States of America
| | - Bruce M Damon
- Dept. of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, United States of America; Carle Clinical Imaging Research Program, Urbana, IL, United States of America; Stephens Family Clinical Research Institute, Carle Health, Urbana, IL, United States of America; Department of Bioengineering and Beckman Institute, University of Illinois at Urbana-Champaign, Urbana, IL, United States of America; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States of America
| |
Collapse
|
4
|
Pan Z, Liu S, Hu J, Luo H, Han M, Sun H, Liu W, Wu Z, Guo H. Improved MR temperature imaging at 0.5 T using view-sharing accelerated multiecho thermometry for MR-guided laser interstitial thermal therapy. NMR IN BIOMEDICINE 2023:e4933. [PMID: 36941216 DOI: 10.1002/nbm.4933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
The aim of the current study was to improve temperature-monitoring precision using multiecho proton resonance frequency shift-based thermometry with view-sharing acceleration for MR-guided laser interstitial thermal therapy (MRgLITT) on a 0.5-T low-field MR system. Both precision and speed of the temperature measurement for clinical MRgLITT treatments suffer at low field, due to reduced image signal-to-noise ratio (SNR), decreased temperature-induced phase changes, and limited RF receiver channels. In this work, a bipolar multiecho gradient-recalled echo sequence with a temperature-to-noise ratio optimal weighted echo combination is applied to improve the temperature precision. A view-sharing-based approach is utilized to accelerate signal acquisitions while preserving image SNRs. The method was evaluated using ex vivo (pork and pig brain) LITT heating experiments and in vivo (human brain) nonheating experiments on a high-performance 0.5-T scanner. In terms of results, (1) after echo combination, multiecho thermometry (i.e., ~7.5-40.5 ms, 7 TEs) provides ~1.5-1.9 times higher temperature precision than the no echo combination case (i.e., TE7 = 40.5 ms) within the same readout bandwidth. Additionally, echo registration is necessary for the bipolar multiecho sequence; (2) for a threefold acceleration, the view-sharing approach with variable-density subsampling shows around 1.8 times lower temperature errors than the GRAPPA method. Particularly for view-sharing, variable-density subsampling performs better than Interleave subsampling; and (3) ex vivo heating and in vivo nonheating experiments demonstrated that the temperature accuracy was less than 0.5 ° C $$ {}^{{}^{\circ}}\mathrm{C} $$ and that the temperature precision was less than 0.6 ° C $$ {}^{{}^{\circ}}\mathrm{C} $$ using the proposed 0.5-T thermometry. It was concluded that view-sharing accelerated multiecho thermometry is a practical temperature measurement approach for MRgLITT at 0.5 T.
Collapse
Affiliation(s)
- Ziyi Pan
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Simin Liu
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | | | - Hai Luo
- Marvel Stone Healthcare, Wuxi, Jiangsu, China
| | - Meng Han
- Sinovation Medical, Beijing, China
| | - Hao Sun
- Sinovation Medical, Beijing, China
| | | | - Ziyue Wu
- Marvel Stone Healthcare, Wuxi, Jiangsu, China
| | - Hua Guo
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| |
Collapse
|
5
|
Shin S, Yun SD, Shah NJ. T2* quantification using multi-echo gradient echo sequences: a comparative study of different readout gradients. Sci Rep 2023; 13:1138. [PMID: 36670286 PMCID: PMC9860026 DOI: 10.1038/s41598-023-28265-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Accepted: 01/16/2023] [Indexed: 01/22/2023] Open
Abstract
To quantify T2*, multiple echoes are typically acquired with a multi-echo gradient echo sequence using either monopolar or bipolar readout gradients. The use of bipolar readout gradients achieves a shorter echo spacing time, enabling the acquisition of a larger number of echoes in the same scan time. However, despite their relative time efficiency and the potential for more accurate quantification, a comparative investigation of these readout gradients has not yet been addressed. This work aims to compare the performance of monopolar and bipolar readout gradients for T2* quantification. The differences in readout gradients were theoretically investigated with a Cramér-Rao lower bound and validated with computer simulations with respect to the various imaging parameters (e.g., flip angle, TR, TE, TE range, and BW). The readout gradients were then compared at 3 T using phantom and in vivo experiments. The bipolar readout gradients provided higher precision than monopolar readout gradients in both computer simulations and experimental results. The difference between the two readout gradients increased for a lower SNR and smaller TE range, consistent with the prediction made using Cramér-Rao lower bound. The use of bipolar readout gradients is advantageous for regions or situations where a lower SNR is expected or a shorter acquisition time is required.
Collapse
Affiliation(s)
- Seonyeong Shin
- grid.8385.60000 0001 2297 375XInstitute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428 Jülich, Germany ,grid.1957.a0000 0001 0728 696XRWTH Aachen University, Aachen, Germany
| | - Seong Dae Yun
- grid.8385.60000 0001 2297 375XInstitute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428 Jülich, Germany
| | - N. Jon Shah
- grid.8385.60000 0001 2297 375XInstitute of Neuroscience and Medicine 4, Forschungszentrum Jülich, INM-4, 52428 Jülich, Germany ,grid.1957.a0000 0001 0728 696XRWTH Aachen University, Aachen, Germany ,grid.494742.8Institute of Neuroscience and Medicine 11, JARA, Forschungszentrum Jülich, INM-11, Jülich, Germany ,JARA-BRAIN-Translational Medicine, Aachen, Germany ,grid.1957.a0000 0001 0728 696XDepartment of Neurology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
6
|
Liu H, Grouza V, Tuznik M, Siminovitch KA, Bagheri H, Peterson A, Rudko DA. Self-labelled encoder-decoder (SLED) for multi-echo gradient echo-based myelin water imaging. Neuroimage 2022; 264:119717. [PMID: 36367497 DOI: 10.1016/j.neuroimage.2022.119717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/07/2022] [Accepted: 10/27/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Reconstruction of high quality myelin water imaging (MWI) maps is challenging, particularly for data acquired using multi-echo gradient echo (mGRE) sequences. A non-linear least squares fitting (NLLS) approach has often been applied for MWI. However, this approach may produce maps with limited detail and, in some cases, sub-optimal signal to noise ratio (SNR), due to the nature of the voxel-wise fitting. In this study, we developed a novel, unsupervised learning method called self-labelled encoder-decoder (SLED) to improve gradient echo-based MWI data fitting. METHODS Ultra-high resolution, MWI data was collected from five mouse brains with variable levels of myelination, using a mGRE sequence. Imaging data was acquired using a 7T preclinical MRI system. A self-labelled, encoder-decoder network was implemented in TensorFlow for calculation of myelin water fraction (MWF) based on the mGRE signal decay. A simulated MWI phantom was also created to evaluate the performance of MWF estimation. RESULTS Compared to NLLS, SLED demonstrated improved MWF estimation, in terms of both stability and accuracy in phantom tests. In addition, SLED produced less noisy MWF maps from high resolution MR microscopy images of mouse brain tissue. It specifically resulted in lower noise amplification for all mouse genotypes that were imaged and yielded mean MWF values in white matter ROIs that were highly correlated with those derived from standard NLLS fitting. Lastly, SLED also exhibited higher tolerance to low SNR data. CONCLUSION Due to its unsupervised and self-labeling nature, SLED offers a unique alternative to analyze gradient echo-based MWI data, providing accurate and stable MWF estimations.
Collapse
Affiliation(s)
- Hanwen Liu
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Vladimir Grouza
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Marius Tuznik
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Katherine A Siminovitch
- Departments of Medicine and Immunology, University of Toronto, Toronto, ON, Canada; Lunenfeld Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON, Canada
| | - Hooman Bagheri
- Department of Human Genetics, McGill University, Montreal, QC, Canada
| | - Alan Peterson
- Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada; Department of Human Genetics, McGill University, Montreal, QC, Canada; Gerald Bronfman Department of Oncology, McGill University, Montreal, QC, Canada
| | - David A Rudko
- McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, QC, Canada; Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada; Department of Biomedical Engineering, McGill University, Montreal, QC, Canada.
| |
Collapse
|
7
|
Li S, Shen C, Ding Z, She H, Du YP. Accelerating multi-echo chemical shift encoded water-fat MRI using model-guided deep learning. Magn Reson Med 2022; 88:1851-1866. [PMID: 35649172 DOI: 10.1002/mrm.29307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 04/30/2022] [Accepted: 05/02/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE To accelerate chemical shift encoded (CSE) water-fat imaging by applying a model-guided deep learning water-fat separation (MGDL-WF) framework to the undersampled k-space data. METHODS A model-guided deep learning water-fat separation framework is proposed for the acceleration using Cartesian/radial undersampling data. The proposed MGDL-WF combines the power of CSE water-fat imaging model and data-driven deep learning by jointly using a multi-peak fat model and a modified residual U-net network. The model is used to guide the image reconstruction, and the network is used to capture the artifacts induced by the undersampling. A data consistency layer is used in MGDL-WF to ensure the output images to be consistent with the k-space measurements. A Gauss-Newton iteration algorithm is adapted for the gradient updating of the networks. RESULTS Compared with the compressed sensing water-fat separation (CS-WF) algorithm/2-step procedure algorithm, the MGDL-WF increased peak signal-to-noise ratio (PSNR) by 5.31/5.23, 6.11/4.54, and 4.75 dB/1.88 dB with Cartesian sampling, and by 4.13/6.53, 2.90/4.68, and 1.68 dB/3.48 dB with radial sampling, at acceleration rates (R) of 4, 6, and 8, respectively. By using MGDL-WF, radial sampling increased the PSNR by 2.07 dB at R = 8, compared with Cartesian sampling. CONCLUSIONS The proposed MGDL-WF enables exploiting features of the water images and fat images from the undersampled multi-echo data, leading to improved performance in the accelerated CSE water-fat imaging. By using MGDL-WF, radial sampling can further improve the image quality with comparable scan time in comparison with Cartesian sampling.
Collapse
Affiliation(s)
- Shuo Li
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenfei Shen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zekang Ding
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Huajun She
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiping P Du
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
8
|
Peng H, Cheng C, Wan Q, Jia S, Wang S, Lv J, Liang D, Liu W, Liu X, Zheng H, Zou C. Fast multi-parametric imaging in abdomen by B 1 + corrected dual-flip angle sequence with interleaved echo acquisition. Magn Reson Med 2021; 87:2194-2208. [PMID: 34888911 DOI: 10.1002/mrm.29127] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 11/28/2021] [Accepted: 11/29/2021] [Indexed: 11/07/2022]
Abstract
PURPOSE To achieve simultaneous T1, w /proton density fat fraction (PDFF)/ R 2 ∗ mapping in abdomen within a single breadth-hold, and validate the accuracy using state-of-art measurement. THEORY AND METHODS An optimized multiple echo gradient echo (GRE) sequence with dual flip-angle acquisition was used to realize simultaneous water T1 (T1, w )/PDFF/ R 2 ∗ quantification. A new method, referred to as "solving the fat-water ambiguity based on their T1 difference" (SORT), was proposed to address the fat-water separation problem. This method was based on the finding that compared to the true solution, the wrong (or aliased) solution to fat-water separation problem showed extra dependency on the applied flip angle due to the T1 difference between fat and water. The B 1 + measurement sequence was applied to correct the B 1 + inhomogeneity for T1, w relaxometry. The 2D parallel imaging was incorporated to enable the acquisition within a single breath-hold in abdomen. RESULTS The multi-parametric quantification results of the proposed method were consistent with the results of reference methods in phantom experiments (PDFF quantification: R2 = 0.993, mean error 0.73%; T1, w quantification: R2 = 0.999, mean error 4.3%; R 2 ∗ quantification: R2 = 0.949, mean error 4.07 s-1 ). For volunteer studies, robust fat-water separation was achieved without evident fat-water swaps. Based on the accurate fat-water separation, simultaneous T1, w /PDFF/ R 2 ∗ quantification was realized for whole liver within a single breath-hold. CONCLUSION The proposed method accurately quantified T1, w /PDFF/ R 2 ∗ for the whole liver within a single breath-hold. This technique serves as a quantitative tool for disease management in patients with hepatic steatosis.
Collapse
Affiliation(s)
- Hao Peng
- School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Chuanli Cheng
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Qian Wan
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Sen Jia
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Shuai Wang
- School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.,Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jianxun Lv
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Wenzhong Liu
- School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan, China.,Key Laboratory of Image Processing and Intelligent Control, Huazhong University of Science and Technology, Wuhan, China
| | - Xin Liu
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| | - Chao Zou
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advance Technology, Chinese Academy of Sciences, Shenzhen, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
9
|
Zijlstra F, Seevinck PR. Multiple-echo steady-state (MESS): Extending DESS for joint T 2 mapping and chemical-shift corrected water-fat separation. Magn Reson Med 2021; 86:3156-3165. [PMID: 34270127 PMCID: PMC8596862 DOI: 10.1002/mrm.28921] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 06/21/2021] [Accepted: 06/21/2021] [Indexed: 12/21/2022]
Abstract
Purpose To extend the double echo steady‐state (DESS) sequence to enable chemical‐shift corrected water‐fat separation. Methods This study proposes multiple‐echo steady‐state (MESS), a sequence that modifies the readouts of the DESS sequence to acquire two echoes each with bipolar readout gradients with higher readout bandwidth. This enables water‐fat separation and eliminates the need for water‐selective excitation that is often used in combination with DESS, without increasing scan time. An iterative fitting approach was used to perform joint chemical‐shift corrected water‐fat separation and T2 estimation on all four MESS echoes simultaneously. MESS and water‐selective DESS images were acquired for five volunteers, and were compared qualitatively as well as quantitatively on cartilage T2 and thickness measurements. Signal‐to‐noise ratio (SNR) and T2 quantification were evaluated numerically using pseudo‐replications of the acquisition. Results The water‐fat separation provided by MESS was robust and with quality comparable to water‐selective DESS. MESS T2 estimation was similar to DESS, albeit with slightly higher variability. Noise analysis showed that SNR in MESS was comparable to DESS on average, but did exhibit local variations caused by uncertainty in the water‐fat separation. Conclusion In the same acquisition time as DESS, MESS provides water‐fat separation with comparable SNR in the reconstructed water and fat images. By providing additional image contrasts in addition to the water‐selective DESS images, MESS provides a promising alternative to DESS.
Collapse
Affiliation(s)
- Frank Zijlstra
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.,Department of Radiology and Nuclear Medicine, St Olav's University Hospital, Trondheim, Norway
| | - Peter R Seevinck
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands.,MRIGuidance BV, Utrecht, The Netherlands
| |
Collapse
|
10
|
Dong Y, Koolstra K, Riedel M, van Osch MJP, Börnert P. Regularized joint water-fat separation with B 0 map estimation in image space for 2D-navigated interleaved EPI based diffusion MRI. Magn Reson Med 2021; 86:3034-3051. [PMID: 34255392 PMCID: PMC8596522 DOI: 10.1002/mrm.28919] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 06/09/2021] [Accepted: 06/16/2021] [Indexed: 12/15/2022]
Abstract
Purpose To develop a new water–fat separation and B0 estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor. Methods Water–fat separation based on chemical‐shift encoding enables robust fat suppression in routine MRI. However, for EPI the different chemical‐shift displacements of the multiple fat resonances along the phase‐encoding direction can be problematic for conventional separation algorithms. This work proposes a suitable model approximation for EPI under B0 and fat off‐resonance effects, providing a feasible multi‐peak water–fat separation algorithm. Simulations were performed to validate the algorithm. In vivo validation was performed in 6 volunteers, acquiring spin‐echo EPI images in the leg (B0 homogeneous) and head‐neck (B0 inhomogeneous) regions, using a TE‐shifted interleaved EPI sequence with/without diffusion sensitization. The results are numerically and statistically compared with voxel‐independent water–fat separation and fat saturation techniques to demonstrate the performance of the proposed algorithm. Results The reference separation algorithm without the proposed spatial shift correction caused water–fat ambiguities in simulations and in vivo experiments. Some spectrally selective fat saturation approaches also failed to suppress fat in regions with severe B0 inhomogeneities. The proposed algorithm was able to achieve improved fat suppression for DWI data and ADC maps in the head–neck and leg regions. Conclusion The proposed algorithm shows improved suppression of the multi‐peak fat components in multi‐shot interleaved EPI applications compared to the conventional fat saturation approaches and separation algorithms.
Collapse
Affiliation(s)
- Yiming Dong
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands
| | - Kirsten Koolstra
- Radiology, Division of Image Processing, Leiden University Medical Center, Leiden, The Netherlands
| | - Malte Riedel
- Institute for Signal Processing, University of Lübeck, Lübeck, Germany
| | - Matthias J P van Osch
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter Börnert
- Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.,Philips Research Hamburg, Hamburg, Germany
| |
Collapse
|
11
|
Bachrata B, Strasser B, Bogner W, Schmid AI, Korinek R, Krššák M, Trattnig S, Robinson SD. Simultaneous Multiple Resonance Frequency imaging (SMURF): Fat-water imaging using multi-band principles. Magn Reson Med 2021; 85:1379-1396. [PMID: 32981114 PMCID: PMC7756227 DOI: 10.1002/mrm.28519] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 07/31/2020] [Accepted: 08/24/2020] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop a fat-water imaging method that allows reliable separation of the two tissues, uses established robust reconstruction methods, and requires only one single-echo acquisition. THEORY AND METHODS The proposed method uses spectrally selective dual-band excitation in combination with CAIPIRINHA to generate separate images of fat and water simultaneously. Spatially selective excitation without cross-contamination is made possible by the use of spatial-spectral pulses. Fat and water images can either be visualized separately, or the fat images can be corrected for chemical shift displacement and, in gradient echo imaging, for chemical shift-related phase discrepancy, and recombined with water images, generating fat-water images free of chemical shift effects. Gradient echo and turbo spin echo sequences were developed based on this Simultaneous Multiple Resonance Frequency imaging (SMURF) approach and their performance was assessed at 3Tesla in imaging of the knee, breasts, and abdomen. RESULTS The proposed method generated well-separated fat and water images with minimal unaliasing artefacts or cross-excitation, evidenced by the near absence of water signal attributed to the fat image and vice versa. The separation achieved was similar to or better than that using separate acquisitions with water- and fat-saturation or Dixon methods. The recombined fat-water images provided similar image contrast to conventional images, but the chemical shift effects were eliminated. CONCLUSION Simultaneous Multiple Resonance Frequency imaging is a robust fat-water imaging technique that offers a solution to imaging of body regions with significant amounts of fat.
Collapse
Affiliation(s)
- Beata Bachrata
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria,Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
| | - Bernhard Strasser
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria,Athinoula A. Martinos Center for Biomedical Imaging, Department of RadiologyMassachusetts General Hospital, Harvard Medical SchoolBostonMAUSA
| | - Wolfgang Bogner
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria
| | - Albrecht Ingo Schmid
- High Field MR Centre, Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Radim Korinek
- Institute of Scientific Instruments of the CASBrnoCzech Republic
| | - Martin Krššák
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria,Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria,Department of Internal Medicine III, Division of Endocrinology and MetabolismMedical University of ViennaViennaAustria
| | - Siegfried Trattnig
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria,Christian Doppler Laboratory for Clinical Molecular MR ImagingViennaAustria
| | - Simon Daniel Robinson
- High Field MR Centre, Department of Biomedical Imaging and Image‐Guided TherapyMedical University of ViennaViennaAustria,Centre of Advanced ImagingUniversity of QueenslandBrisbaneQLDAustralia,Department of NeurologyMedical University of GrazGrazAustria
| |
Collapse
|
12
|
Aigner CS, Dietrich S, Schmitter S. Three-dimensional static and dynamic parallel transmission of the human heart at 7 T. NMR IN BIOMEDICINE 2021; 34:e4450. [PMID: 33325581 DOI: 10.1002/nbm.4450] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 11/04/2020] [Accepted: 11/05/2020] [Indexed: 06/12/2023]
Abstract
Three-dimensional (3D) human heart imaging at ultra-high fields is highly challenging due to respiratory and cardiac motion-induced artifacts as well as spatially heterogeneous B1+ profiles. In this study, we investigate the feasibility of applying 3D flip angle (FA) homogenization targeting the whole heart via static phase-only and dynamic kT-point in vivo parallel transmission at 7 T. 3D B1+ maps of the thorax were acquired under free breathing in eight subjects to compute parallel transmission pulses that improve excitation homogeneity in the human heart. To analyze the number of kT-points required, excitation homogeneity and radiofrequency (RF) power were compared using different regions of interest in six subjects with different body mass index (BMI) values of 20-34 kg/m2 for a wide range of regularization parameters. One subset of the optimized subject-specific pulses was applied in vivo on a 7 T scanner for six subjects in Cartesian 3D breath-hold scans as well as in two subjects in a radial phase-encoded 3D free-breathing scan. Across all subjects, 3-4 kT-points achieved a good tradeoff between RF power and nominal FA homogeneity. For subjects with a BMI in the normal range, the 4 kT-point pulses reliably improved the coefficient of variation by less than 10% compared with less than 25% achieved by static phase-only parallel transmission. in vivo measurements on a 7 T scanner validated the B1+ estimations and the pulse design, despite neglecting ΔB0 in the optimizations and Bloch simulations. This study demonstrates in vivo that kT-point pTx pulses are highly suitable for mitigating nominal FA heterogeneities across the entire 3D heart volume at 7 T. Furthermore, 3-4 kT-points demonstrate a practical tradeoff between nominal FA heterogeneity mitigation and RF power.
Collapse
Affiliation(s)
| | | | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Germany
- University of Minnesota, Center for Magnetic Resonance Research, Minneapolis, Minnesota
| |
Collapse
|
13
|
Rydén H, Norbeck O, Avventi E, Skorpil M, van Niekerk A, Skare S, Berglund J. Chemical shift encoding using asymmetric readout waveforms. Magn Reson Med 2020; 85:1468-1480. [PMID: 33090529 PMCID: PMC7756491 DOI: 10.1002/mrm.28529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 08/20/2020] [Accepted: 09/01/2020] [Indexed: 11/25/2022]
Abstract
Purpose To describe a new method for encoding chemical shift using asymmetric readout waveforms that enables more SNR‐efficient fat/water imaging. Methods Chemical shift was encoded using asymmetric readout waveforms, rather than conventional shifted trapezoid readouts. Two asymmetric waveforms are described: a triangle and a spline. The concept was applied to a fat/water separated RARE sequence to increase sampling efficiency. The benefits were investigated through comparisons to shifted trapezoid readouts. Using asymmetric readout waveforms, the scan time was either shortened or maintained to increase SNR. A matched in‐phase waveform is also described that aims to improve the SNR transfer function of the fat and water estimates. The sequence was demonstrated for cervical spine, musculoskeletal (MSK), and optic nerve applications at 3T and compared with conventional shifted readouts. Results By removing sequence dead times, scan times were shortened by 30% with maintained SNR. The shorter echo spacing also reduced
T2 blurring. Maintaining the scan times and using asymmetric readout waveforms achieved an SNR improvement in agreement with the prolonged sampling duration. Conclusions Asymmetric readout waveforms offer an additional degree of freedom in pulse sequence designs where chemical shift encoding is desired. This can be used to significantly shorten scan times or to increase SNR with maintained scan time.
Collapse
Affiliation(s)
- Henric Rydén
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Ola Norbeck
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Enrico Avventi
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Mikael Skorpil
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Adam van Niekerk
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Stefan Skare
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Johan Berglund
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
14
|
Ruetten PPR, Cluroe AD, Usman A, Priest AN, Gillard JH, Graves MJ. Simultaneous MRI water‐fat separation and quantitative susceptibility mapping of carotid artery plaque pre‐ and post‐ultrasmall superparamagnetic iron oxide‐uptake. Magn Reson Med 2020; 84:686-697. [DOI: 10.1002/mrm.28151] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/28/2019] [Accepted: 12/08/2019] [Indexed: 12/20/2022]
Affiliation(s)
| | - Alison D. Cluroe
- Department of Histopathology Addenbrooke’s Hospital Histopathology, Cambridge United Kingdom
| | - Ammara Usman
- Department of Radiology University of Cambridge Cambridge United Kingdom
| | - Andrew N. Priest
- Department of Medical Physics Cambridge University Hospitals NHS Foundation Trust Cambridge United Kingdom
| | | | - Martin J. Graves
- Department of Radiology Cambridge University Hospitals NHS Foundation Trust Cambridge United Kingdom
| |
Collapse
|
15
|
Constraints in estimating the proton density fat fraction. Magn Reson Imaging 2019; 66:1-8. [PMID: 31740195 DOI: 10.1016/j.mri.2019.11.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 10/16/2019] [Accepted: 11/09/2019] [Indexed: 11/21/2022]
Abstract
The study evaluates four physically motivated constraints in the estimation of the proton density fat fraction (PDFF). Least squares approaches were developed for constraining the parameters in PDFF quantification based on the physics of magnetic resonance imaging. These were smooth fieldmap, smooth initial phase, nonnegative proton density and moderate R2∗ values. The constraints were evaluated in terms of their influence on the bias and standard deviation of the estimated parameters using numerical simulations and in vivo data acquired at 0.35 T. Results show that unconstrained least squares estimation is noisy and biased and that constraints can be effective at reducing both the standard deviation and bias.
Collapse
|
16
|
Berglund J, Rydén H, Avventi E, Norbeck O, Sprenger T, Skare S. Fat/water separation in k‐space with real‐valued estimates and its combination with POCS. Magn Reson Med 2019; 83:653-661. [DOI: 10.1002/mrm.27949] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 07/09/2019] [Accepted: 07/24/2019] [Indexed: 01/10/2023]
Affiliation(s)
- Johan Berglund
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Department of Neuroradiology Karolinska University Hospital Stockholm Sweden
| | - Henric Rydén
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Department of Neuroradiology Karolinska University Hospital Stockholm Sweden
| | - Enrico Avventi
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Department of Neuroradiology Karolinska University Hospital Stockholm Sweden
| | - Ola Norbeck
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Department of Neuroradiology Karolinska University Hospital Stockholm Sweden
| | - Tim Sprenger
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Applied Science Laboratory Europe GE Healthcare Stockholm Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience Karolinska Institutet Stockholm Sweden
- Department of Neuroradiology Karolinska University Hospital Stockholm Sweden
| |
Collapse
|
17
|
Zou C, Cheng C, Qiao Y, Wan Q, Tie C, Pan M, Liang D, Zheng H, Liu X. Hierarchical iterative linear-fitting algorithm (HILA) for phase correction in fat quantification by bipolar multi-echo sequence. Quant Imaging Med Surg 2019; 9:247-262. [PMID: 30976549 DOI: 10.21037/qims.2019.02.07] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Background Multi-echo gradient echo (GRE) sequence with bipolar readout gradients can reduce achievable echo spacing and thus have higher acquisition efficiency compared to unipolar readout gradients for fat fraction (FF) quantification. However, the eddy current induced phase (EC-phase) in a bipolar sequence corrupts the phase consistency between echoes and can lead to inaccurate fat quantification. Methods A hierarchical iterative linear-fitting algorithm (HILA) was proposed for EC-phase correction. In each iteration, image blocks were divided into sub-blocks. The EC-phase was fitted to a linear model in each sub-block. The estimated linear phase in each sub-block was then used as a starting value for the next iteration. Finally, a weighted average over all levels was calculated to obtain the final EC-phase map. Monte Carlo simulations were adopted to evaluate how the residual EC-phase would affect FF quantification accuracy. The performance of the proposed HILA method was then compared to the well-established unipolar acquisition method in phantom and in vivo experiments on 3T. Results The simulations showed that certain ΔTE values, such as ΔTE =~0.80/1.50/1.95 ms, allowed for FF estimation that were relatively robust to the residual EC-phase ranging from -2π/15 to 2π/15 for a 6-echo bipolar acquisition on 3T. The phantom study showed that the maximum mean FF error, after EC-phase correction with the proposed HILA method, was smaller than 2%, implying that HILA can approximate the high-order term of the EC-phase through step-wise linear fitting. There was no significant difference between the FFs from bipolar and unipolar acquisitions on the two MR systems in the in vivo experiments. Conclusions The proposed HILA method provides a simple and efficient EC-phase correction method for bipolar acquisition without acquiring additional data. The appropriate choice of TEs may further reduce the effect of the residual EC-phase on accurate FF quantification with bipolar readout sequence.
Collapse
Affiliation(s)
- Chao Zou
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Chuanli Cheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yangzi Qiao
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Qian Wan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.,Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China
| | - Changjun Tie
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Min Pan
- Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen 518049, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.,Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine, Chongqing 400016, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.,Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine, Chongqing 400016, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.,Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine, Chongqing 400016, China
| |
Collapse
|
18
|
Peng H, Zou C, Cheng C, Tie C, Qiao Y, Wan Q, Lv J, He Q, Liang D, Liu X, Liu W, Zheng H. Fat‐water separation based on Transition REgion Extraction (TREE). Magn Reson Med 2019; 82:436-448. [DOI: 10.1002/mrm.27710] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Revised: 01/29/2019] [Accepted: 02/05/2019] [Indexed: 12/26/2022]
Affiliation(s)
- Hao Peng
- Huazhong University of Science and Technology Wuhan China
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
| | - Chao Zou
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Chuanli Cheng
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Changjun Tie
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
| | - Yangzi Qiao
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
| | - Qian Wan
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Jianxun Lv
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Qiang He
- Shanghai United Imaging Healthcare Co., Ltd Shanghai China
| | - Dong Liang
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Xin Liu
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| | - Wenzhong Liu
- Huazhong University of Science and Technology Wuhan China
| | - Hairong Zheng
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen China
- University of Chinese Academy of Sciences Beijing China
| |
Collapse
|
19
|
Cho J, Park H. Robust water–fat separation for multi‐echo gradient‐recalled echo sequence using convolutional neural network. Magn Reson Med 2019; 82:476-484. [DOI: 10.1002/mrm.27697] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Revised: 01/10/2019] [Accepted: 01/25/2019] [Indexed: 12/24/2022]
Affiliation(s)
- JaeJin Cho
- Department of Electrical Engineering Korea Advanced Institute of Science and Technology (KAIST) Daejeon South Korea
| | - HyunWook Park
- Department of Electrical Engineering Korea Advanced Institute of Science and Technology (KAIST) Daejeon South Korea
| |
Collapse
|
20
|
Schneider M, Janas G, Lugauer F, Hoppe E, Nickel D, Dale BM, Kiefer B, Maier A, Bashir MR. Accurate fatty acid composition estimation of adipose tissue in the abdomen based on bipolar multi‐echo MRI. Magn Reson Med 2018; 81:2330-2346. [DOI: 10.1002/mrm.27557] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 08/18/2018] [Accepted: 09/11/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Manuel Schneider
- Pattern Recognition Lab, Department of Computer Science Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
| | - Gemini Janas
- Radiology Duke University Medical Center Durham North Carolina
- Center for Advanced Magnetic Resonance Development Duke University Medical Center Durham North Carolina
| | - Felix Lugauer
- Pattern Recognition Lab, Department of Computer Science Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
| | - Elisabeth Hoppe
- Pattern Recognition Lab, Department of Computer Science Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
| | - Dominik Nickel
- MR Applications Predevelopment Siemens Healthcare GmbH Erlangen Germany
| | - Brian M. Dale
- MR R&D Collaborations Siemens Healthineers Cary North Carolina
| | - Berthold Kiefer
- MR Applications Predevelopment Siemens Healthcare GmbH Erlangen Germany
| | - Andreas Maier
- Pattern Recognition Lab, Department of Computer Science Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
| | - Mustafa R. Bashir
- Radiology Duke University Medical Center Durham North Carolina
- Center for Advanced Magnetic Resonance Development Duke University Medical Center Durham North Carolina
| |
Collapse
|
21
|
Cho J, Park H. Technical Note: Interleaved bipolar acquisition and low‐rank reconstruction for water–fat separation in
MRI. Med Phys 2018; 45:3229-3237. [DOI: 10.1002/mp.12981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 05/07/2018] [Accepted: 05/07/2018] [Indexed: 11/06/2022] Open
Affiliation(s)
- JaeJin Cho
- Department of Electrical Engineering Korea Advanced Institute of Science and Technology (KAIST) Daejeon South Korea
| | - HyunWook Park
- Department of Electrical Engineering Korea Advanced Institute of Science and Technology (KAIST) Daejeon South Korea
| |
Collapse
|
22
|
Single multi-echo GRE acquisition with short and long echo spacing for simultaneous quantitative mapping of fat fraction, B0 inhomogeneity, and susceptibility. Neuroimage 2018; 172:703-717. [DOI: 10.1016/j.neuroimage.2018.02.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 02/01/2018] [Accepted: 02/06/2018] [Indexed: 12/23/2022] Open
|
23
|
Rydén H, Berglund J, Norbeck O, Avventi E, Skare S. T1 weighted fat/water separated PROPELLER acquired with dual bandwidths. Magn Reson Med 2018; 80:2501-2513. [DOI: 10.1002/mrm.27228] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/28/2018] [Accepted: 03/29/2018] [Indexed: 11/12/2022]
Affiliation(s)
- Henric Rydén
- Department of Neuroradiology; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Neuroscience; Karolinska Institutet; Stockholm Sweden
| | - Johan Berglund
- Department of Neuroradiology; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Neuroscience; Karolinska Institutet; Stockholm Sweden
| | - Ola Norbeck
- Department of Neuroradiology; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Neuroscience; Karolinska Institutet; Stockholm Sweden
| | - Enrico Avventi
- Department of Neuroradiology; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Neuroscience; Karolinska Institutet; Stockholm Sweden
| | - Stefan Skare
- Department of Neuroradiology; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Neuroscience; Karolinska Institutet; Stockholm Sweden
| |
Collapse
|
24
|
Validation of goose liver fat measurement by QCT and CSE-MRI with biochemical extraction and pathology as reference. Eur Radiol 2017; 28:2003-2012. [PMID: 29238866 DOI: 10.1007/s00330-017-5189-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 11/05/2017] [Accepted: 11/09/2017] [Indexed: 12/19/2022]
Abstract
OBJECTIVES This study aimed to validate the accuracy and reliability of quantitative computed tomography (QCT) and chemical shift encoded magnetic resonance imaging (CSE-MRI) to assess hepatic steatosis. METHODS Twenty-two geese with a wide range of hepatic steatosis were collected. After QCT and CSE-MRI examinations, the liver of each goose was removed and samples were taken from the left lobe, upper and lower half of the right lobe for biochemical measurement and histology. Fat percentages by QCT and proton density fat fraction by MRI (MRI-PDFF) were measured within the sample regions of biochemical measurement and histology. The accuracy of QCT and MR measurements were assessed through Spearman correlation coefficients (r) and Passing and Bablok regression equations using biochemical measurement as the "gold standard". RESULTS Both QCT and MRI correlated highly with chemical extraction [r = 0.922 (p < 0.001) and r = 0.949 (p < 0.001) respectively]. Chemically extracted triglyceride was accurately predicted by both QCT liver fat percentages (Y = 0.6 + 0.866 × X) and by MRI-PDFF (Y = -1.8 + 0.773 × X). CONCLUSIONS QCT and CSE-MRI measurements of goose liver fat were accurate and reliable compared with biochemical measurement. KEY POINTS • QCT and CSE-MRI can measure liver fat content accurately and reliably • Histological grading of hepatic steatosis has larger sampling variability • QCT and CSE-MRI have potential in the clinical setting.
Collapse
|
25
|
Jung W, Lee J, Shin HG, Nam Y, Zhang H, Oh SH, Lee J. Whole brain g-ratio mapping using myelin water imaging (MWI) and neurite orientation dispersion and density imaging (NODDI). Neuroimage 2017; 182:379-388. [PMID: 28962901 DOI: 10.1016/j.neuroimage.2017.09.053] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2017] [Revised: 08/23/2017] [Accepted: 09/24/2017] [Indexed: 10/18/2022] Open
Abstract
MR g-ratio, which measures the ratio of the aggregate volume of axons to that of fibers in a voxel, is a potential biomarker for white matter microstructures. In this study, a new approach for acquiring an in-vivo whole human brain g-ratio map is proposed. To estimate the g-ratio, myelin volume fraction and axonal volume fraction are acquired using multi-echo gradient echo myelin water imaging (GRE-MWI) and neurite orientation dispersion and density imaging (NODDI), respectively. In order to translate myelin water fraction measured in GRE-MWI into myelin volume fraction, a new scaling procedure is proposed and validated. This scaling approach utilizes geometric measures of myelin structure and, therefore, provides robustness over previous methods. The resulting g-ratio map reveals an expected range of g-ratios (0.71-0.85 in major fiber bundles) with a small inter-subject coefficient of variance (less than 2%). Additionally, a few fiber bundles (e.g. cortico-spinal tract and optic radiation) show different constituents of myelin volume fraction and axonal volume fraction, indicating potentials to utilize the measures for deciphering fiber tracking.
Collapse
Affiliation(s)
- Woojin Jung
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
| | - Jingu Lee
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
| | - Hyeong-Geol Shin
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea
| | - Yoonho Nam
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Hui Zhang
- Department of Computer Science & Centre for Medical Image Computing, University College London, London, United Kingdom
| | - Se-Hong Oh
- Division of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, South Korea
| | - Jongho Lee
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea.
| |
Collapse
|
26
|
Mao D, Li Y, Liu P, Peng SL, Pillai JJ, Lu H. Three-dimensional mapping of brain venous oxygenation using R2* oximetry. Magn Reson Med 2017; 79:1304-1313. [PMID: 28585238 DOI: 10.1002/mrm.26763] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Revised: 04/07/2017] [Accepted: 05/03/2017] [Indexed: 11/11/2022]
Abstract
PURPOSE Cerebral venous oxygenation (Yv ) is an important biomarker for brain diseases. This study aims to develop an R2*-based MR oximetry that can measure cerebral Yv in 3D. METHODS This technique separates blood signal from tissue by velocity-encoding phase contrast and measures the R2* of pure blood by multi-gradient-echo acquisition. The blood R2* was converted to Yv using an R2*-versus-oxygenation (Y) calibration curve, which was obtained by in vitro bovine blood experiments. Reproducibility, sensitivity, validity, and resolution dependence of the technique were evaluated. RESULTS In vitro R2*-Y calibration plot revealed a strong dependence of blood R2* on oxygenation, with additional dependence on hematocrit. In vivo results demonstrated that the technique can provide a 3D venous oxygenation map that depicts both large sinuses and smaller cortical veins, with venous oxygenation ranging from 57 to 72%. Intrasession coefficient of variation of the measurement was 3.0%. The technique detected an average Yv increase of 10.8% as a result of hyperoxia, which was validated by global oxygenation measurement from T2 -Relaxation-Under-Spin-Tagging (TRUST) MRI. Two spatial resolutions, one with an isotropic voxel dimension and the other with a nonisotropic dimension, were tested for full brain coverage. CONCLUSIONS This study demonstrated the feasibility of 3D brain oxygenation mapping without using contrast agent. Magn Reson Med 79:1304-1313, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Deng Mao
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Graduate School of Biomedical Sciences, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Yang Li
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Graduate School of Biomedical Sciences, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Peiying Liu
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Shin-Lei Peng
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan
| | - Jay J Pillai
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hanzhang Lu
- The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
27
|
Kolbitsch C, Neji R, Fenchel M, Mallia A, Marsden P, Schaeffter T. Fully integrated 3D high-resolution multicontrast abdominal PET-MR with high scan efficiency. Magn Reson Med 2017; 79:900-911. [DOI: 10.1002/mrm.26757] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 03/29/2017] [Accepted: 04/22/2017] [Indexed: 12/19/2022]
Affiliation(s)
- Christoph Kolbitsch
- Physikalisch-Technische Bundesanstalt (PTB); Braunschweig and Berlin Germany
- King's College London, Division of Imaging Sciences and Biomedical Engineering; London UK
| | - Radhouene Neji
- MR Research Collaborations, Siemens Healthcare; Frimley UK
| | - Matthias Fenchel
- MR Oncology Application Development, Siemens Healthcare; Erlangen Germany
| | - Andrew Mallia
- King's College London, Division of Imaging Sciences and Biomedical Engineering; London UK
| | - Paul Marsden
- King's College London, Division of Imaging Sciences and Biomedical Engineering; London UK
| | - Tobias Schaeffter
- Physikalisch-Technische Bundesanstalt (PTB); Braunschweig and Berlin Germany
- King's College London, Division of Imaging Sciences and Biomedical Engineering; London UK
| |
Collapse
|
28
|
Armstrong T, Dregely I, Stemmer A, Han F, Natsuaki Y, Sung K, Wu HH. Free-breathing liver fat quantification using a multiecho 3D stack-of-radial technique. Magn Reson Med 2017; 79:370-382. [PMID: 28419582 DOI: 10.1002/mrm.26693] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 02/22/2017] [Accepted: 03/09/2017] [Indexed: 12/11/2022]
Abstract
PURPOSE The diagnostic gold standard for nonalcoholic fatty liver disease is an invasive biopsy. Noninvasive Cartesian MRI fat quantification remains limited to a breath-hold (BH). In this work, a novel free-breathing 3D stack-of-radial (FB radial) liver fat quantification technique is developed and evaluated in a preliminary study. METHODS Phantoms and healthy subjects (n = 11) were imaged at 3 Tesla. The proton-density fat fraction (PDFF) determined using FB radial (with and without scan acceleration) was compared to BH single-voxel MR spectroscopy (SVS) and BH 3D Cartesian MRI using linear regression (correlation coefficient ρ and concordance coefficient ρc ) and Bland-Altman analysis. RESULTS In phantoms, PDFF showed significant correlation (ρ > 0.998, ρc > 0.995) and absolute mean differences < 2.2% between FB radial and BH SVS, as well as significant correlation (ρ > 0.999, ρc > 0.998) and absolute mean differences < 0.6% between FB radial and BH Cartesian. In the liver and abdomen, PDFF showed significant correlation (ρ > 0.986, ρc > 0.985) and absolute mean differences < 1% between FB radial and BH SVS, as well as significant correlation (ρ > 0.996, ρc > 0.995) and absolute mean differences < 0.9% between FB radial and BH Cartesian. CONCLUSION Accurate 3D liver fat quantification can be performed in 1 to 2 min using a novel FB radial technique. Magn Reson Med 79:370-382, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Tess Armstrong
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Physics and Biology in Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
| | - Isabel Dregely
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Biomedical Engineering, King's College London, London, United Kingdom
| | | | - Fei Han
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | | | - Kyunghyun Sung
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Physics and Biology in Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
| | - Holden H Wu
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.,Department of Physics and Biology in Medicine, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
| |
Collapse
|
29
|
Measurement of vertebral bone marrow proton density fat fraction in children using quantitative water-fat MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 30:449-460. [PMID: 28382554 DOI: 10.1007/s10334-017-0617-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 03/23/2017] [Accepted: 03/24/2017] [Indexed: 12/21/2022]
Abstract
OBJECTIVES To investigate the feasibility of employing a 3D time-interleaved multi-echo gradient-echo (TIMGRE) sequence to measure the proton density fat fraction (PDFF) in the vertebral bone marrow (VBM) of children and to examine cross-sectional changes with age and intra-individual variations from the lumbar to the cervical region in the first two decades of life. MATERIALS AND METHODS Quantitative water-fat imaging of the spine was performed in 93 patients (49 girls; 44 boys; age median 4.5 years; range 0.1-17.6 years). For data acquisition, a six-echo 3D TIMGRE sequence was used with phase correction and complex-based water-fat separation. Additionally, single-voxel MR spectroscopy (MRS) was performed in the L4 vertebrae of 37 patients. VBM was manually segmented in the midsagittal slice of each vertebra. Univariable and multivariable linear regression models were calculated between averaged lumbar, thoracic and cervical bone marrow PDFF and age with adjustments for sex, height, weight, and body mass index percentile. RESULTS Measured VBM PDFF correlated strongly between imaging and MRS (R 2 = 0.92, slope = 0.94, intercept = -0.72%). Lumbar, thoracic and cervical VBM PDFF correlated significantly (all p < 0.001) with the natural logarithm of age. Differences between female and male patients were not significant (p > 0.05). CONCLUSION VBM development in children showed a sex-independent cross-sectional increase of PDFF correlating with the natural logarithm of age and an intra-individual decrease of PDFF from the lumbar to the cervical region in all age groups. The present results demonstrate the feasibility of using a 3D TIMGRE sequence for PDFF assessment in VBM of children.
Collapse
|
30
|
Dagher J, Nael K. MR phase imaging with bipolar acquisition. NMR IN BIOMEDICINE 2017; 30:10.1002/nbm.3523. [PMID: 27149433 PMCID: PMC5097709 DOI: 10.1002/nbm.3523] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2015] [Revised: 01/20/2016] [Accepted: 02/26/2016] [Indexed: 06/05/2023]
Abstract
We have previously proposed a novel magnetic resonance (MR) phase imaging framework (MAGPI) based on a three-echo sequence that demonstrated substantial gains in phase signal-to-noise ratio (SNR). We improve upon the performance of MAGPI by extending the formulation to handle (i) an alternating gradient polarity (bipolar) readout scheme and (ii) an arbitrary number of echoes. We formulate the phase-imaging problem using maximum-likelihood (ML) estimation. The acquisition uses an optimized multi-echo gradient echo (MEGE) sequence. The tissue-phase estimation algorithm is a voxel-per-voxel approach, which requires no reference scans, no phase unwrapping and no spatial denoising. Unlike other methods, our bipolar readout model is general and does not make simplifying assumptions about the even-odd echo phase errors. The results show that (a) our proposed bipolar MAGPI approach improves on the phase SNR gains achieved with monopolar MAGPI and (b) the phase SNR converges with the number of echoes more rapidly with bipolar MAGPI. Importantly, bipolar MAGPI enables phase imaging in severely SNR-constrained scenarios, where monopolar MAGPI is unable to find solutions. The substantial phase SNR gains achieved with our framework are used here to (a) accelerate acquisitions (full brain 0.89 mm in-plane resolution in 2 min 30 sec) and (b) enable high-contrast high-resolution phase imaging (310 µm in-plane resolution) at clinical field strengths. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Joseph Dagher
- Corresponding author: ; 1609 N. Warren Bldg 211 Rm 110, Tucson, AZ, USA 85719; (520) 621-0809
| | | |
Collapse
|
31
|
Kim H, Kim DH, Sohn CH, Park J. Rapid chemical shift encoding with single-acquisition single-slab 3D GRASE. Magn Reson Med 2017; 78:1852-1861. [DOI: 10.1002/mrm.26595] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2016] [Revised: 12/08/2016] [Accepted: 12/08/2016] [Indexed: 12/21/2022]
Affiliation(s)
- Hahnsung Kim
- Department of Biomedical Engineering; Sungkyunkwan University; Suwon Republic of Korea
- Department of Electrical and Electronic Engineering; Yonsei University; Seoul Republic of Korea
| | - Dong-Hyun Kim
- Department of Electrical and Electronic Engineering; Yonsei University; Seoul Republic of Korea
| | - Chul-Ho Sohn
- Department of Radiology; Seoul National University Hospital; Seoul Republic of Korea
| | - Jaeseok Park
- Department of Biomedical Engineering; Sungkyunkwan University; Suwon Republic of Korea
| |
Collapse
|
32
|
Nam Y, Gho SM, Kim DH, Kim EY, Lee J. Imaging of nigrosome 1 in substantia nigra at 3T using multiecho susceptibility map-weighted imaging (SMWI). J Magn Reson Imaging 2016; 46:528-536. [PMID: 27859983 DOI: 10.1002/jmri.25553] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 10/26/2016] [Indexed: 12/26/2022] Open
Abstract
PURPOSE To enhance the visibility of nigrosome 1 in substantia nigra, which has recently been suggested as an imaging biomarker for Parkinson's disease (PD) at 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS The substantia nigra structure was visualized at 3T MRI using multiecho susceptibility map-weighted imaging (SMWI) in 15 healthy volunteers and 6 patients with Parkinson's disease (PD). The visibility of nigrosome 1 was further enhanced by acquiring data in an oblique-coronal imaging plane at a high spatial resolution (0.5 × 0.5 × 1.0 mm3 ). To compare the visibility, the contrast-to-noise ratios (CNR) of the nigrosome 1 structure relative to the neighboring substantia nigra structure were evaluated in the SMWI and other conventional susceptibility contrast images (magnitude, frequency, quantitative susceptibility map [QSM] and susceptibility-weighted image). RESULTS In healthy volunteers, the CNRs of the nigrosome 1 structure were 1.04 ± 0.38, 0.84 ± 0.32, 1.04 ± 0.40, 0.86 ± 0.41, and 1.45 ± 0.48 for magnitude, frequency, quantitative susceptibility map, susceptibility-weighted image, and SMWI, respectively. Compared to conventional susceptibility contrast images, the SMWI method significantly improved the CNR of nigrosome 1 (P = 0.014 for magnitude, P = 0.030 for QSM, and P < 0.001 for frequency and SWI, respectively). The magnetic susceptibility difference between nigrosome 1 and neighboring substantia nigra structures was 0.037 ± 0.016 ppm (measured in QSM, P < 0.001) in healthy volunteers. In the PD patients, the visibility of the nigrosome 1 structures was reduced. CONCLUSION The SMWI method enhances the visibility of nigrosome 1 structures at 3T MRI when compared to conventional susceptibility contrast images. LEVEL OF EVIDENCE 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:528-536.
Collapse
Affiliation(s)
- Yoonho Nam
- Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Sung-Min Gho
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | - Dong-Hyun Kim
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
| | - Eung Yeop Kim
- Department of Radiology, Gachon University Gil Medical Center, Incheon, Korea
| | - Jongho Lee
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Korea
| |
Collapse
|
33
|
Ruschke S, Eggers H, Kooijman H, Diefenbach MN, Baum T, Haase A, Rummeny EJ, Hu HH, Karampinos DC. Correction of phase errors in quantitative water-fat imaging using a monopolar time-interleaved multi-echo gradient echo sequence. Magn Reson Med 2016; 78:984-996. [PMID: 27797100 DOI: 10.1002/mrm.26485] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 09/06/2016] [Accepted: 09/08/2016] [Indexed: 12/11/2022]
Abstract
PURPOSE To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS A three-step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time-interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field-induced PDFF bias and the performance estimating the phase offset between time-interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. RESULTS The simulation, phantom, and in vivo results showed in agreement with the theory an echo time-dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. CONCLUSION Complex-based time-interleaved water-fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984-996, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Stefan Ruschke
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | | | | | - Maximilian N Diefenbach
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Thomas Baum
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Axel Haase
- Institute of Medical Engineering, Technical University of Munich, Garching, Germany
| | - Ernst J Rummeny
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Houchun H Hu
- Radiology, Phoenix Children's Hospital, Phoenix, Arizona, USA
| | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| |
Collapse
|
34
|
Berglund J, Skorpil M. Multi-scale graph-cut algorithm for efficient water-fat separation. Magn Reson Med 2016; 78:941-949. [DOI: 10.1002/mrm.26479] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Revised: 08/30/2016] [Accepted: 09/01/2016] [Indexed: 12/28/2022]
Affiliation(s)
- Johan Berglund
- Department of Medical Radiation Physics; Karolinska University Hospital; Stockholm Sweden
- Department of Clinical Science; Intervention and Technology, Karolinska Institute; Stockholm Sweden
| | - Mikael Skorpil
- Department of Radiology; Uppsala University Hospital; Uppsala Sweden
- Department of Radiation Sciences; Umeå University; Umeå Sweden
| |
Collapse
|
35
|
Jang H, McMillan AB. A rapid and robust gradient measurement technique using dynamic single-point imaging. Magn Reson Med 2016; 78:950-962. [PMID: 27699867 DOI: 10.1002/mrm.26481] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 09/01/2016] [Accepted: 09/02/2016] [Indexed: 12/20/2022]
Abstract
PURPOSE We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory. METHODS To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system. RESULTS The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom. CONCLUSION The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Hyungseok Jang
- Department of Radiology, Wisconsin Institute for Medical Research, University of Wisconsin, Madison, Wisconsin, USA.,Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Alan B McMillan
- Department of Radiology, Wisconsin Institute for Medical Research, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
36
|
Baron CA, Nishimura DG. B 0 mapping using rewinding trajectories (BMART). Magn Reson Med 2016; 78:664-669. [PMID: 27555219 DOI: 10.1002/mrm.26391] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 07/27/2016] [Accepted: 07/27/2016] [Indexed: 11/10/2022]
Abstract
PURPOSE To create a B0 map and correct for off-resonance with minimal scan time increase for two-dimensional (2D) or 3D non-Cartesian acquisitions. METHODS Rewinding trajectories that bring the zeroth gradient moment to zero every repetition time (TR) were used to estimate the off-resonance with a center-out 3D cones trajectory, which required an increase in the minimum TR by 5%. The off-resonance estimation and correction was implemented using an algorithm based on binning and object-domain phase correction. B0 maps using BMART (B0 mapping using rewinding trajectories) were compared to maps obtained using separate scans with multiple echo time (TE) in a phantom and human brain. RESULTS Excellent agreement between BMART and the multiple-TE method were observed, and images corrected with BMART were deblurred. CONCLUSION BMART can correct for off-resonance without requiring an additional scan, and can be easily applied to center-out or projection trajectories (2D or 3D). Magn Reson Med 78:664-669, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Corey A Baron
- Department of Electrical Engineering, Magnetic Resonance Systems Research Laboratory, Stanford University, Stanford, California, USA
| | - Dwight G Nishimura
- Department of Electrical Engineering, Magnetic Resonance Systems Research Laboratory, Stanford University, Stanford, California, USA
| |
Collapse
|
37
|
Son JB, Hwang KP, Madewell JE, Bayram E, Hazle JD, Low RN, Ma J. A flexible fast spin echo triple-echo Dixon technique. Magn Reson Med 2016; 77:1049-1057. [PMID: 26982770 DOI: 10.1002/mrm.26186] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Revised: 02/08/2016] [Accepted: 02/08/2016] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw images with relative phase shifts of -θ, 0, and θ between water and fat signals. A region growing-based two-point Dixon phase correction algorithm was used to joint process two separate pairs of the three raw images, yielding a final set of water-only and fat-only images. The flexible FTED technique was implemented on 1.5T and 3.0T scanners and evaluated in five subjects for fat-suppressed T2-weighted imaging and in one subject for post-contrast fat-suppressed T1-weighted imaging. RESULTS The flexible FTED technique achieved a high data acquisition efficiency, comparable to that of FSE, and was flexible in scan protocols. The joint two-point Dixon phase correction algorithm helped to ensure consistency in the processing of the two separate pairs of raw images. Reliable and uniform separation of water and fat was achieved in all of the test cases. CONCLUSION The flexible FTED technique incorporates the benefits of both FSE and Dixon imaging and provided more flexibility than the original FTED in applications such as fat-suppressed T2-weighted and T1-weighted imaging. Magn Reson Med 77:1049-1057, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Jong Bum Son
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Ken-Pin Hwang
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - John E Madewell
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Ersin Bayram
- Global MR Applications and Workflow, GE Healthcare Technologies, Waukesha, Wisconsin, USA
| | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Russell N Low
- Sharp and Children's MRI Center and San Diego Imaging Medical Group, San Diego, California, USA
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
38
|
Yilmaz O, Saritas EU, Çukur T. Enhanced phase-sensitive SSFP reconstruction for fat-water separation in phased-array acquisitions. J Magn Reson Imaging 2015; 44:148-57. [PMID: 26696005 DOI: 10.1002/jmri.25138] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Accepted: 12/08/2015] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To propose and assess a method to improve the reliability of phase-sensitive fat-water separation for phased-array balanced steady-state free precession (bSSFP) acquisitions. Phase-sensitive steady-state free precession (PS-SSFP) is an efficient fat-water separation technique that detects the phase difference between neighboring bands in the bSSFP magnetization profile. However, large spatial variations in the sensitivity profiles of phased-array coils can lead to noisy phase estimates away from the coil centers, compromising tissue classification. MATERIALS AND METHODS We first perform region-growing phase correction in individual coil images via unsupervised selection of a fat-voxel seed near the peak of each coil's sensitivity profile. We then use an optimal linear combination of phase-corrected images to segregate fat and water signals. The proposed method was demonstrated on noncontrast-enhanced SSFP angiograms of the thigh, lower leg, and foot acquired at 1.5T using an 8-channel coil. Individual coil PS-SSFP with a common seed selection for all coils, individual coil PS-SSFP with coil-wise seed selection, PS-SSFP after coil combination, and IDEAL reconstructions were also performed. Water images reconstructed via PS-SSFP methods were compared in terms of the level of fat suppression and the similarity to reference IDEAL images (signed-rank test). RESULTS While tissue misclassification was broadly evident across regular PS-SSFP images, the proposed method achieved significantly higher levels of fat suppression (P < 0.005) and increased similarity to reference IDEAL images (P < 0.005). CONCLUSION The proposed method enhances fat-water separation in phased-array acquisitions by producing improved phase estimates across the imaging volume. J. Magn. Reson. Imaging 2016;44:148-157.
Collapse
Affiliation(s)
- Ozgur Yilmaz
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey
| | - Emine Ulku Saritas
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey.,Neuroscience Program, Bilkent University, Ankara, Turkey
| | - Tolga Çukur
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center, Bilkent University, Ankara, Turkey.,Neuroscience Program, Bilkent University, Ankara, Turkey
| |
Collapse
|
39
|
Hedderich DM, Weiss K, Maintz D, Persigehl T. [Modern magnetic resonance imaging of the liver]. Radiologe 2015; 55:1045-56. [PMID: 26628259 DOI: 10.1007/s00117-015-0031-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Magnetic resonance imaging (MRI) of the liver has become an essential tool in the radiological diagnostics of both focal and diffuse diseases of the liver and is subject to constant change due to technological progress. Recently, important improvements could be achieved by innovations regarding MR hardware, sequences and postprocessing methods. The diagnostic spectrum of MRI could be broadened particularly due to new examination sequences, while at the same time scanning time could be shortened and image quality has been improved. The aim of this article is to explain both the technological background and the clinical application of recent MR sequence developments and to present the scope of a modern MRI protocol for the liver.
Collapse
Affiliation(s)
- D M Hedderich
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - K Weiss
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Köln, Kerpener Str. 62, 50937, Köln, Deutschland.,Philips Healthcare Deutschland, Hamburg, Deutschland
| | - D Maintz
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - T Persigehl
- Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Köln, Kerpener Str. 62, 50937, Köln, Deutschland.
| |
Collapse
|
40
|
Leporq B, Lambert SA, Ronot M, Boucenna I, Colinart P, Cauchy F, Vilgrain V, Paradis V, Van Beers BE. Hepatic fat fraction and visceral adipose tissue fatty acid composition in mice: Quantification with 7.0T MRI. Magn Reson Med 2015; 76:510-8. [PMID: 26527483 DOI: 10.1002/mrm.25895] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Revised: 07/23/2015] [Accepted: 07/25/2015] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop an MRI method for quantifying hepatic fat content and visceral adipose tissue fatty acid composition in mice on a 7.0T preclinical system. METHODS MR acquisitions were performed with a multiple echo spoiled gradient echo with bipolar readout gradients. After phase correction, the number of double bounds (ndb) and the number of methylene interrupted double bounds (nmidb) were quantified with a model including eight fat components, and parametric maps of saturated, monounsaturated, and polyunsaturated fatty acids were derived. The model included a complex error map to correct for the phase errors and the amplitude modulation caused by the bipolar acquisition. Validations were performed in fat-water emulsions and vegetable oils. In vivo, the feasibility was evaluated in mice receiving a high-fat diet containing primarily saturated fatty acids and a low-fat diet containing primarily unsaturated fatty acids. RESULTS Linear regressions showed strong agreements between ndb and nmidb quantified with MRI and the theoretical values calculated using oil compositions, as well as between the proton density and the fat fractions in the emulsions. At MRI, the mouse liver fat fraction was smaller in mice fed the low-fat diet compared with mice fed the high-fat diet. In visceral adipose tissue, saturated fatty acids were significantly higher, whereas monounsaturated and polyunsaturated fatty acids were significantly lower in mice fed the low-fat diet compared with mice fed the high-fat diet. CONCLUSION It is feasible to simultaneously quantify hepatic fat content and visceral adipose tissue fatty acid composition with 7.0T MRI in mice. Magn Reson Med 76:510-518, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Collapse
Affiliation(s)
- Benjamin Leporq
- Laboratory of Imaging Biomarkers, Center of Research on Inflammation, UMR1149 INSERM-University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Simon A Lambert
- Laboratory of Imaging Biomarkers, Center of Research on Inflammation, UMR1149 INSERM-University Paris Diderot, Sorbonne Paris Cité, Paris, France.,BHF Centre of Excellence, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St. Thomas' Hospital, London, United Kingdom
| | - Maxime Ronot
- Laboratory of Imaging Biomarkers, Center of Research on Inflammation, UMR1149 INSERM-University Paris Diderot, Sorbonne Paris Cité, Paris, France.,Department of Radiology, Beaujon University Hospital Paris Nord, Clichy, France
| | - Imane Boucenna
- Matière et Systèmes Complexes, UMR 7057 CNRS-University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Pierre Colinart
- Matière et Systèmes Complexes, UMR 7057 CNRS-University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Francois Cauchy
- Department of HPB and liver transplantation, Beaujon University Hospital Paris Nord, Clichy, France
| | - Valerie Vilgrain
- Laboratory of Imaging Biomarkers, Center of Research on Inflammation, UMR1149 INSERM-University Paris Diderot, Sorbonne Paris Cité, Paris, France.,Department of Radiology, Beaujon University Hospital Paris Nord, Clichy, France
| | - Valerie Paradis
- Department of Pathology, Beaujon University Hospital Paris Nord, Clichy, France
| | - Bernard E Van Beers
- Laboratory of Imaging Biomarkers, Center of Research on Inflammation, UMR1149 INSERM-University Paris Diderot, Sorbonne Paris Cité, Paris, France.,Department of Radiology, Beaujon University Hospital Paris Nord, Clichy, France
| |
Collapse
|
41
|
Mann LW, Higgins DM, Peters CN, Cassidy S, Hodson KK, Coombs A, Taylor R, Hollingsworth KG. Accelerating MR Imaging Liver Steatosis Measurement Using Combined Compressed Sensing and Parallel Imaging: A Quantitative Evaluation. Radiology 2015. [PMID: 26218662 DOI: 10.1148/radiol.2015150320] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
PURPOSE To determine the limits of agreement of hepatic fat fraction and R2* relaxation rate quantified with accelerated magnetic resonance (MR) imaging reconstructed with combined compressed sensing and parallel imaging compared with conventional fully sampled acquisitions. MATERIALS AND METHODS Eleven subjects with type 2 diabetes and a healthy control subject were recruited with the approval of the Newcastle and North Tyneside 2 ethics committee and written consent. Undersampled data at ratios of 2.6×, 2.9×, 3.8×, and 4.8× were prospectively acquired in addition to fully sampled data by using five gradient echoes per repetition time at 3.0 T. Fat fraction maps were calculated by using combined compressed sensing and parallel imaging (CS-PI) reconstruction and Bland-Altman analysis performed to assess bias and 95% limits of agreement. Inter- and intrarater analysis was performed for quantitative fat fraction and R2* relaxation rate, and image quality was assessed with a four-point scale by two independent observers. RESULTS The fat fractions from the accelerated acquisitions had 95% limits of agreement of 1.2%, 1.2%, 1.1%, and 1.5%, respectively, with no bias. When compared with the intra- and interrater 95% limits of agreement (0.7% and 0.8%), acceleration of up to 3.8× did not greatly degrade the fat fraction measurements. No or minimal artifact was detected at 2.6× and 2.9× accelerations, moderate artifact was detected at 3.8× acceleration, and substantial artifact was detected at 4.8× acceleration. CONCLUSION Prospective undersampling and CS-PI reconstruction of liver fat fractions can be used to accelerate liver fat fraction measurements. The fat fractions and image quality produced were acceptable up to a factor of 3.8×, thereby shortening the required breath-hold duration from 17.7 seconds to 4.7 seconds.
Collapse
Affiliation(s)
- Louis W Mann
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - David M Higgins
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Carl N Peters
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Sophie Cassidy
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Kenneth K Hodson
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Anna Coombs
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Roy Taylor
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| | - Kieren G Hollingsworth
- From the Newcastle Magnetic Resonance Centre (L.W.M., C.N.P., K.K.H., A.C., R.T., K.G.H.) and MoveLab (S.C.), Institute of Cellular Medicine, Newcastle University, Newcastle upon Tyne, NE4 5PL, England; and Philips Healthcare, Guildford, England (D.M.H.)
| |
Collapse
|
42
|
Soliman AS, Wiens CN, Wade TP, McKenzie CA. Fat quantification using an interleaved bipolar acquisition. Magn Reson Med 2015; 75:2000-8. [DOI: 10.1002/mrm.25807] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Revised: 05/20/2015] [Accepted: 05/21/2015] [Indexed: 12/11/2022]
Affiliation(s)
- Abraam S. Soliman
- Biomedical Engineering; Western University; London Canada
- Robarts Research Institute; Western University; London Canada
| | - Curtis N. Wiens
- Department of Radiology; University of Wisconsin-Madison; Madison Wisconsin USA
| | - Trevor P. Wade
- Robarts Research Institute; Western University; London Canada
- Department of Medical Biophysics; Western University; London Canada
| | - Charles A. McKenzie
- Biomedical Engineering; Western University; London Canada
- Robarts Research Institute; Western University; London Canada
- Department of Medical Biophysics; Western University; London Canada
| |
Collapse
|
43
|
Phase-corrected bipolar gradients in multi-echo gradient-echo sequences for quantitative susceptibility mapping. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2014; 28:347-55. [PMID: 25408108 DOI: 10.1007/s10334-014-0470-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Revised: 09/25/2014] [Accepted: 10/22/2014] [Indexed: 10/24/2022]
Abstract
OBJECTIVE Large echo spacing of unipolar readout gradients in current multi-echo gradient-echo (GRE) sequences for mapping fields in quantitative susceptibility mapping (QSM) can be reduced using bipolar readout gradients thereby improving acquisition efficiency. MATERIALS AND METHODS Phase discrepancies between odd and even echoes in the bipolar readout gradients caused by non-ideal gradient behaviors were measured, modeled as polynomials in space and corrected for accordingly in field mapping. The bipolar approach for multi-echo GRE field mapping was compared with the unipolar approach for QSM. RESULTS The odd-even-echo phase discrepancies were approximately constant along the phase encoding direction and linear along the readout and slice-selection directions. A simple linear phase correction in all three spatial directions was shown to enable accurate QSM of the human brain using a bipolar multi-echo GRE sequence. Bipolar multi-echo acquisition provides QSM in good quantitative agreement with unipolar acquisition while also reducing noise. CONCLUSION With a linear phase correction between odd-even echoes, bipolar readout gradients can be used in multi-echo GRE sequences for QSM.
Collapse
|
44
|
Rahimi MS, Holmes JH, Wang K, Reeder SB, Korosec FR. Flow-induced signal misallocation artifacts in two-point fat-water chemical shift MRI. Magn Reson Med 2014; 73:1926-31. [PMID: 24911325 DOI: 10.1002/mrm.25315] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 05/21/2014] [Accepted: 05/21/2014] [Indexed: 12/22/2022]
Abstract
PURPOSE Two-point fat-water separation methods are increasingly being used for chest and abdominal MRI and have recently been introduced for use in MR angiography of the lower extremities. With these methods, flowing spins can accumulate unintended phase shifts between the echo times. The purpose of this study is to demonstrate that these phase shifts can lead to inaccurate signals in the water and fat images. THEORY AND METHODS In vitro experiments were conducted at 1.5T and 3.0T using a stenosis-mimicking phantom and a computer-controlled pump to image a range of physiologically relevant velocities. RESULTS In the phantom images acquired using bipolar readout gradients, fat-water signal inaccuracies were visible in regions of flow, with increasing severity as the flow rate was increased. Additionally, similar effects were observed in regions of high flow in clinical chest and liver exams. In the phantom images, the effect was eliminated by using a dual-pass method without bipolar readout gradients. CONCLUSION When using fat-water separation methods with bipolar readout gradients, phase shifts caused by the motion of spins can lead to signal inaccuracies in the fat and water images. These artifacts can be mitigated by using approaches that do not use bipolar readout gradients.
Collapse
Affiliation(s)
- Mahdi Salmani Rahimi
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | | | | | | |
Collapse
|
45
|
Chen Y, Cai C, Zhong J, Chen Z. Water-fat separation from a single spatiotemporally encoded echo based on nominal k-space peaking and joint regularized estimation. Magn Reson Med 2014; 73:1441-9. [PMID: 24798405 DOI: 10.1002/mrm.25261] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2013] [Revised: 03/26/2014] [Accepted: 04/01/2014] [Indexed: 11/08/2022]
Abstract
PURPOSE To present a new high-resolution single-point water-fat separation algorithm based on the spatiotemporally encoded chemical shift imaging technique. THEORY Identifying water and fat peaks on the ensemble of the nominal k-space profiles of all spatiotemporally encoded lines enables evaluation of the mean off-resonance frequencies of the two components. With utilization of the spatial smoothness and filtering regularizations, the water/fat profiles can be discriminated with twice joint linear least squares estimations line-by-line. METHODS The effectiveness of the proposed algorithm was assessed by experiments on oil-water phantoms and in vivo in rats at 7T using a spatiotemporally encoded variant of the multishot spin-echo sequence. The results were compared with those obtained from previously proposed 1-point Dixon, 2-point Dixon, and 3-point IDEAL methods. RESULTS The results demonstrate that the new technique can achieve high-quality water-fat separations, comparable in signal-to-noise ratio and contrast to the multipoint methods and is more robust in cases when large areas of low signals or motion artifacts jeopardize the results from the 1-point Dixon method. CONCLUSIONS The proposed technique is potentially a new viable alternative for single-point water-fat separation.
Collapse
Affiliation(s)
- Ying Chen
- Department of Electronics Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| | | | | | | |
Collapse
|
46
|
Eggers H, Börnert P. Chemical shift encoding-based water-fat separation methods. J Magn Reson Imaging 2014; 40:251-68. [PMID: 24446249 DOI: 10.1002/jmri.24568] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 12/12/2013] [Indexed: 12/13/2022] Open
Abstract
The suppression of signal from fat constitutes a basic requirement in many applications of magnetic resonance imaging. To date, this is predominantly achieved during data acquisition, using fat saturation, inversion recovery, or water excitation methods. Postponing the separation of signal from water and fat until image reconstruction holds the promise of resolving some of the problems associated with these methods, such as failure in the presence of field inhomogeneities or contrast agents. In this article, methods are reviewed that rely on the difference in chemical shift between the hydrogen atoms in water and fat to perform such a retrospective separation. The basic principle underlying these so-called Dixon methods is introduced, and some fundamental implementations of the required chemical shift encoding in the acquisition and the subsequent water-fat separation in the reconstruction are described. Practical issues, such as the selection of key parameters and the appearance of typical artifacts, are illustrated, and a broad range of applications is demonstrated, including abdominal, cardiovascular, and musculoskeletal imaging. Finally, advantages and disadvantages of these Dixon methods are summarized, and emerging opportunities arising from the availability of information on the amount and distribution of fat are discussed.
Collapse
|
47
|
Moran CJ, Brodsky EK, Bancroft LH, Reeder SB, Yu H, Kijowski R, Engel D, Block WF. High-resolution 3D radial bSSFP with IDEAL. Magn Reson Med 2013; 71:95-104. [PMID: 23504943 DOI: 10.1002/mrm.24633] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 12/16/2012] [Accepted: 12/18/2012] [Indexed: 12/19/2022]
Abstract
Radial trajectories facilitate high-resolution balanced steady state free precession (bSSFP) because the efficient gradients provide more time to extend the trajectory in k-space. A number of radial bSSFP methods that support fat-water separation have been developed; however, most of these methods require an environment with limited B0 inhomogeneity. In this work, high-resolution bSSFP with fat-water separation is achieved in more challenging B0 environments by combining a 3D radial trajectory with the IDEAL chemical species separation method. A method to maintain very high resolution within the timing constraints of bSSFP and IDEAL is described using a dual-pass pulse sequence. The sampling of a unique set of radial lines at each echo time is investigated as a means to circumvent the longer scan time that IDEAL incurs as a multiecho acquisition. The manifestation of undersampling artifacts in this trajectory and their effect on chemical species separation are investigated in comparison to the case in which each echo samples the same set of radial lines. This new bSSFP method achieves 0.63 mm isotropic resolution in a 5-min scan and is demonstrated in difficult in vivo imaging environments, including the breast and a knee with ACL reconstruction hardware at 1.5 T.
Collapse
Affiliation(s)
- Catherine J Moran
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | | | | | | | | | | | | | | |
Collapse
|
48
|
Peterson P, Månsson S. Fat quantification using multiecho sequences with bipolar gradients: investigation of accuracy and noise performance. Magn Reson Med 2013; 71:219-29. [PMID: 23412971 DOI: 10.1002/mrm.24657] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 12/20/2012] [Accepted: 01/03/2013] [Indexed: 02/01/2023]
Abstract
PURPOSE To investigate the accuracy and noise performance of fat quantification with multiple gradient-echo images acquired using bipolar read-out gradients and compare them with those of the well-established unipolar technique. THEORY The bipolar read-out technique induces phase and amplitude errors caused by gradient delays, eddy currents, and frequency-dependent coil sensitivity. In this study, these errors were corrected for jointly with the fat/water separation by modeling the impact of these effects on the signal. This approach did not require acquisition of reference data or modification of the pulse sequence. METHODS Simulations and a phantom experiment were used to investigate the accuracy and noise performance of the technique and compare them with those of a well-established technique using unipolar read-out gradients. Also, the in vivo feasibility was demonstrated for abdominal applications. RESULTS The phantom experiment demonstrated similar accuracy of the bipolar and unipolar fat quantification techniques. In addition, the noise performance was shown not to be affected by the added estimations of the phase and amplitude errors for most inter-echo times. CONCLUSION The bipolar technique was found to provide accurate fat quantification with noise performance similar to the unipolar technique given an appropriate choice of inter-echo time.
Collapse
Affiliation(s)
- Pernilla Peterson
- Department of Medical Radiation Physics, Lund University, Skåne University Hospital, Malmö, Sweden
| | | |
Collapse
|
49
|
Feng W, Neelavalli J, Haacke EM. Catalytic multiecho phase unwrapping scheme (CAMPUS) in multiecho gradient echo imaging: Removing phase wraps on a voxel-by-voxel basis. Magn Reson Med 2012; 70:117-26. [DOI: 10.1002/mrm.24457] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2012] [Revised: 07/04/2012] [Accepted: 07/17/2012] [Indexed: 12/22/2022]
|
50
|
Le Y, Kroeker R, Kipfer HD, Lin C. Development and evaluation of TWIST Dixon for dynamic contrast-enhanced (DCE) MRI with improved acquisition efficiency and fat suppression. J Magn Reson Imaging 2012; 36:483-91. [PMID: 22544731 DOI: 10.1002/jmri.23663] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2011] [Accepted: 03/07/2012] [Indexed: 02/06/2023] Open
Abstract
PURPOSE To develop a new pulse sequence called time-resolved angiography with stochastic trajectories (TWIST) Dixon for dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS The method combines dual-echo Dixon to generate separated water and fat images with a k-space view-sharing scheme developed for 3D TWIST. The performance of TWIST Dixon was compared with a volume interpolated breathhold examination (VIBE) sequence paired with spectrally selective adiabatic inversion Recovery (SPAIR) and quick fat-sat (QFS) fat-suppression techniques at 3.0T using quantitative measurements of fat-suppression accuracy and signal-to-noise ratio (SNR) efficiency, as well as qualitative breast image evaluations. RESULTS The water fraction of a uniform phantom was calculated from the following images: 0.66 ± 0.03 for TWIST Dixon; 0.56 ± 0.23 for VIBE-SPAIR, and 0.53 ± 0.14 for VIBE-QFS, while the reference value is 0.70 measured by spectroscopy. For phantoms with contrast (Gd-BOPTA) concentration ranging from 0-6 mM, TWIST Dixon also provides consistently higher SNR efficiency (3.2-18.9) compared with VIBE-SPAIR (2.8-16.8) and VIBE-QFS (2.4-12.5). Breast images acquired with TWIST Dixon at 3.0T show more robust and uniform fat suppression and superior overall image quality compared with VIBE-SPAIR. CONCLUSION The results from phantom and volunteer evaluation suggest that TWIST Dixon outperforms conventional methods in almost every aspect and it is a promising method for DCE-MRI and contrast-enhanced perfusion MRI, especially at higher field strength where fat suppression is challenging.
Collapse
Affiliation(s)
- Yuan Le
- Department of Radiology and Imaging Science, Indiana University School of Medicine, Indianapolis, IN 46202, USA
| | | | | | | |
Collapse
|