1
|
Berry DB, Galinsky VL, Hutchinson EB, Galons JP, Ward SR, Frank LR. Double pulsed field gradient diffusion MRI to assess skeletal muscle microstructure. Magn Reson Med 2023; 90:1582-1593. [PMID: 37392410 PMCID: PMC11390096 DOI: 10.1002/mrm.29751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/28/2023] [Accepted: 05/21/2023] [Indexed: 07/03/2023]
Abstract
PURPOSE Preliminary study to determine whether double pulsed field gradient (PFG) diffusion MRI is sensitive to key features of muscle microstructure related to function. METHODS The restricted diffusion profile of molecules in models of muscle microstructure derived from histology were systematically simulated using a numerical simulation approach. Diffusion tensor subspace imaging analysis of the diffusion signal was performed, and spherical anisotropy (SA) was calculated for each model. Linear regression was used to determine the predictive capacity of SA on the fiber area, fiber diameter, and surface area to volume ratio of the models. Additionally, a rat model of muscle hypertrophy was scanned using a single PFG and a double PFG pulse sequence, and the restricted diffusion measurements were compared with histological measurements of microstructure. RESULTS Excellent agreement between SA and muscle fiber area (r2 = 0.71; p < 0.0001), fiber diameter (r2 = 0.83; p < 0.0001), and surface area to volume ratio (r2 = 0.97; p < 0.0001) in simulated models was found. In a scanned rat leg, the distribution of these microstructural features measured from histology was broad and demonstrated that there is a wide variance in the microstructural features observed, similar to the SA distributions. However, the distribution of fractional anisotropy measurements in the same tissue was narrow. CONCLUSIONS This study demonstrates that SA-a scalar value from diffusion tensor subspace imaging analysis-is highly sensitive to muscle microstructural features predictive of function. Furthermore, these techniques and analysis tools can be translated to real experiments in skeletal muscle. The increased dynamic range of SA compared with fractional anisotropy in the same tissue suggests increased sensitivity to detecting changes in tissue microstructure.
Collapse
Affiliation(s)
- D B Berry
- Department of Orthopedic Surgery, University of California, San Diego, California, USA
- Department of Nanoengineering, University of California, San Diego, San Diego, California, USA
| | - V L Galinsky
- Center for Scientific Computation in Imaging, University of California, San Diego, San Diego, California, USA
| | - E B Hutchinson
- Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA
| | - J P Galons
- Department of Medical Imaging, University of Arizona, Tucson, Arizona, USA
| | - S R Ward
- Department of Orthopedic Surgery, University of California, San Diego, California, USA
- Department of Radiology, University of California, San Diego, California, USA
- Department of Bioengineering, University of California, San Diego, California, USA
| | - L R Frank
- Center for Scientific Computation in Imaging, University of California, San Diego, San Diego, California, USA
| |
Collapse
|
2
|
Ulloa P, Methot V, Wottschel V, Koch MA. Extra-axonal contribution to double diffusion encoding-based pore size estimates in the corticospinal tract. MAGMA (NEW YORK, N.Y.) 2023; 36:589-612. [PMID: 36745290 PMCID: PMC10468962 DOI: 10.1007/s10334-022-01058-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 12/14/2022] [Accepted: 12/19/2022] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To study the origin of compartment size overestimation in double diffusion encoding MRI (DDE) in vivo experiments in the human corticospinal tract. Here, the extracellular space is hypothesized to be the origin of the DDE signal. By exploiting the DDE sensitivity to pore shape, it could be possible to identify the origin of the measured signal. The signal difference between parallel and perpendicular diffusion gradient orientation can indicate if a compartment is regular or eccentric in shape. As extracellular space can be considered an eccentric compartment, a positive difference would mean a high contribution to the compartment size estimates. MATERIALS AND METHODS Computer simulations using MISST and in vivo experiments in eight healthy volunteers were performed. DDE experiments using a double spin-echo preparation with eight perpendicular directions were measured in vivo. The difference between parallel and perpendicular gradient orientations was analyzed using a Wilcoxon signed-rank test and a Mann-Whitney U test. RESULTS Simulations and MR experiments showed a statistically significant difference between parallel and perpendicular diffusion gradient orientation signals ([Formula: see text]). CONCLUSION The results suggest that the DDE-based size estimate may be considerably influenced by the extra-axonal compartment. However, the experimental results are also consistent with purely intra-axonal contributions in combination with a large fiber orientation dispersion.
Collapse
Affiliation(s)
- Patricia Ulloa
- Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| | - Vincent Methot
- Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| | - Viktor Wottschel
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, De Boelelaan 1117, 1081, Amsterdam, The Netherlands
| | - Martin A. Koch
- Institute of Medical Engineering, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany
| |
Collapse
|
3
|
Ludwig D, Laun FB, Ladd ME, Bachert P, Kuder TA. Apparent exchange rate imaging: On its applicability and the connection to the real exchange rate. Magn Reson Med 2021; 86:677-692. [PMID: 33749019 DOI: 10.1002/mrm.28714] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 01/11/2021] [Accepted: 01/15/2021] [Indexed: 12/15/2022]
Abstract
PURPOSE Water exchange between the intracellular and extracellular space can be measured using apparent exchange rate (AXR) imaging. The aim of this study was to investigate the relationship between the measured AXR and the geometry of diffusion restrictions, membrane permeability, and the real exchange rate, as well as to explore the applicability of AXR for typical human measurement settings. METHODS The AXR measurements and the underlying exchange rates were simulated using the Monte Carlo method with different geometries, size distributions, packing densities, and a broad range of membrane permeabilities. Furthermore, the influence of SNR and sequence parameters was analyzed. RESULTS The estimated AXR values correspond to the simulated values and show the expected proportionality to membrane permeability, except for fast exchange (ie, AXR > 20 - 30 s - 1 ) and small packing densities. Moreover, it was found that the duration of the filter gradient must be shorter than 2 · AX R - 1 . In cell size and permeability distributions, AXR depends on the average surface-to-volume ratio, permeability, and the packing density. Finally, AXR can be reliably determined in the presence of orientation dispersion in axon-like structures with sufficient gradient sampling (ie, 30 gradient directions). CONCLUSION Currently used experimental settings for in vivo human measurements are well suited for determining AXR, with the exception of single-voxel analysis, due to limited SNR. The detection of changes in membrane permeability in diseased tissue is nonetheless challenging because of the AXR dependence on further factors, such as packing density and geometry, which cannot be disentangled without further knowledge of the underlying cell structure.
Collapse
Affiliation(s)
- Dominik Ludwig
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Frederik Bernd Laun
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | - Mark Edward Ladd
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.,Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| | - Peter Bachert
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Tristan Anselm Kuder
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
4
|
Henriques RN, Palombo M, Jespersen SN, Shemesh N, Lundell H, Ianuş A. Double diffusion encoding and applications for biomedical imaging. J Neurosci Methods 2020; 348:108989. [PMID: 33144100 DOI: 10.1016/j.jneumeth.2020.108989] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/25/2020] [Accepted: 10/20/2020] [Indexed: 12/11/2022]
Abstract
Diffusion Magnetic Resonance Imaging (dMRI) is one of the most important contemporary non-invasive modalities for probing tissue structure at the microscopic scale. The majority of dMRI techniques employ standard single diffusion encoding (SDE) measurements, covering different sequence parameter ranges depending on the complexity of the method. Although many signal representations and biophysical models have been proposed for SDE data, they are intrinsically limited by a lack of specificity. Advanced dMRI methods have been proposed to provide additional microstructural information beyond what can be inferred from SDE. These enhanced contrasts can play important roles in characterizing biological tissues, for instance upon diseases (e.g. neurodegenerative, cancer, stroke), aging, learning, and development. In this review we focus on double diffusion encoding (DDE), which stands out among other advanced acquisitions for its versatility, ability to probe more specific diffusion correlations, and feasibility for preclinical and clinical applications. Various DDE methodologies have been employed to probe compartment sizes (Section 3), decouple the effects of microscopic diffusion anisotropy from orientation dispersion (Section 4), probe displacement correlations, study exchange, or suppress fast diffusing compartments (Section 6). DDE measurements can also be used to improve the robustness of biophysical models (Section 5) and study intra-cellular diffusion via magnetic resonance spectroscopy of metabolites (Section 7). This review discusses all these topics as well as important practical aspects related to the implementation and contrast in preclinical and clinical settings (Section 9) and aims to provide the readers a guide for deciding on the right DDE acquisition for their specific application.
Collapse
Affiliation(s)
- Rafael N Henriques
- Champalimaud Research, Champalimaud Centre for the Unknown, Lisbon, Portugal
| | - Marco Palombo
- Centre for Medical Image Computing and Dept. of Computer Science, University College London, London, UK
| | - Sune N Jespersen
- Center of Functionally Integrative Neuroscience (CFIN) and MINDLab, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark
| | - Noam Shemesh
- Champalimaud Research, Champalimaud Centre for the Unknown, Lisbon, Portugal
| | - Henrik Lundell
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Denmark
| | - Andrada Ianuş
- Champalimaud Research, Champalimaud Centre for the Unknown, Lisbon, Portugal.
| |
Collapse
|
5
|
Jelescu IO, Palombo M, Bagnato F, Schilling KG. Challenges for biophysical modeling of microstructure. J Neurosci Methods 2020; 344:108861. [PMID: 32692999 PMCID: PMC10163379 DOI: 10.1016/j.jneumeth.2020.108861] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/10/2020] [Accepted: 07/14/2020] [Indexed: 02/07/2023]
Abstract
The biophysical modeling efforts in diffusion MRI have grown considerably over the past 25 years. In this review, we dwell on the various challenges along the journey of bringing a biophysical model from initial design to clinical implementation, identifying both hurdles that have been already overcome and outstanding issues. First, we describe the critical initial task of selecting which features of tissue microstructure can be estimated using a model and which acquisition protocol needs to be implemented to make the estimation possible. The model performance should necessarily be tested in realistic numerical simulations and in experimental data - adapting the fitting strategy accordingly, and parameter estimates should be validated against complementary techniques, when/if available. Secondly, the model performance and validity should be explored in pathological conditions, and, if appropriate, dedicated models for pathology should be developed. We build on examples from tumors, ischemia and demyelinating diseases. We then discuss the challenges associated with clinical translation and added value. Finally, we single out four major unresolved challenges that are related to: the availability of a microstructural ground truth, the validation of model parameters which cannot be accessed with complementary techniques, the development of a generalized standard model for any brain region and pathology, and the seamless communication between different parties involved in the development and application of biophysical models of diffusion.
Collapse
|
6
|
Duchêne G, Abarca-Quinones J, Feza-Bingi N, Leclercq I, Duprez T, Peeters F. Double Diffusion Encoding for Probing Radiation-Induced Microstructural Changes in a Tumor Model: A Proof-of-Concept Study With Comparison to the Apparent Diffusion Coefficient and Histology. J Magn Reson Imaging 2020; 52:941-951. [PMID: 32147929 DOI: 10.1002/jmri.27119] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 02/17/2020] [Accepted: 02/18/2020] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Microstructure analyses are gaining interest in cancer MRI as an alternative to the conventional apparent diffusion coefficient (ADC), of which the determinants remain unclear. PURPOSE To assess the sensitivity of parameters calculated from a double diffusion encoding (DDE) sequence to changes in a tumor's microstructure early after radiotherapy and to compare them with ADC and histology. STUDY TYPE Cohort study on experimental tumors. ANIMAL MODEL Sixteen WAG/Rij rats grafted with one rhabdomyosarcoma fragment in each thigh. Thirty-one were imaged at days 1 and 4, of which 17 tumors received a 20 Gy radiation dose after the first imagery. FIELD STRENGTH/SEQUENCE 3T. Diffusion-weighted imaging, DDE with flow compensated, and noncompensated measurements. ASSESSMENTS 1) To compare, after irradiation, DDE-derived parameters (intracellular fraction, cell size, and cell density) to their histological counterparts (fraction of stained area, minimal Feret diameter, and nuclei count, respectively). 2) To compare percentage changes in DDE-derived parameters and ADC. 3) To evaluate the evolution of DDE-derived parameters describing perfusion. STATISTICAL TESTS Wilcoxon rank sum test. RESULTS 1) Intracellular fraction, cell size, and cell density were respectively lower (-24%, P < 0.001), higher (+7.5%, P < 0.001) and lower (-38%, P < 0.001) in treated tumors as compared to controls. Fraction of stained area, minimal Feret diameter, and nuclei count were respectively lower (-20%, P < 0.001), higher (+28%, P < 0.001), and lower (-34%, P < 0.001) in treated tumors. 2) The magnitude of ADC's percentage change due to irradiation (16.4%) was superior to the one of cell size (8.4%, P < 0.01) but inferior to those of intracellular fraction (35.5%, P < 0.001) and cell density (42%, P < 0.001). 3) After treatment, the magnitude of the vascular fraction's decrease was higher than the increase of flow velocity (33.3%, vs. 13.3%, P < 0.001). DATA CONCLUSION The DDE sequence allows quantitatively monitoring the effects of radiotherapy on a tumor's microstructure, whereas ADC only reveals global changes. EVIDENCE LEVEL 2. TECHNICAL EFFICACY Stage 4. J. Magn. Reson. Imaging 2020;52:941-951.
Collapse
Affiliation(s)
- Gaëtan Duchêne
- Department of medical imaging, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium
| | - Jorge Abarca-Quinones
- Department of medical imaging, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium.,MRI unit, Department of medical imaging, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Natacha Feza-Bingi
- Department of medical imaging, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium.,Laboratory of Hepato-gastroenterology, Institut de Recherche Expérimentale et Clinique, Université catholique de Louvain, Brussels, Belgium
| | - Isabelle Leclercq
- Department of medical imaging, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium.,MRI unit, Department of medical imaging, Cliniques Universitaires Saint-Luc, Brussels, Belgium.,Laboratory of Hepato-gastroenterology, Institut de Recherche Expérimentale et Clinique, Université catholique de Louvain, Brussels, Belgium
| | - Thierry Duprez
- Department of medical imaging, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Brussels, Belgium.,MRI unit, Department of medical imaging, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| | - Frank Peeters
- MRI unit, Department of medical imaging, Cliniques Universitaires Saint-Luc, Brussels, Belgium
| |
Collapse
|
7
|
Frank LR, Zahneisen B, Galinsky VL. JEDI: Joint Estimation Diffusion Imaging of macroscopic and microscopic tissue properties. Magn Reson Med 2020; 84:966-990. [PMID: 31916626 DOI: 10.1002/mrm.28141] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 11/12/2019] [Accepted: 11/30/2019] [Indexed: 11/07/2022]
Abstract
PURPOSE A new method for enhancing the sensitivity of diffusion MRI (dMRI) by combining the data from single (sPFG) and double (dPFG) pulsed field gradient experiments is presented. METHODS This method uses our JESTER framework to combine microscopic anisotropy information from dFPG experiments using a new method called diffusion tensor subspace imaging (DiTSI) to augment the macroscopic anisotropy information from sPFG data analyzed using our guided by entropy spectrum pathways method. This new method, called joint estimation diffusion imaging (JEDI), combines the sensitivity to macroscopic diffusion anisotropy of sPFG with the sensitivity to microscopic diffusion anisotropy of dPFG methods. RESULTS Its ability to produce significantly more detailed anisotropy maps and more complete fiber tracts than existing methods within both brain white matter (WM) and gray matter (GM) is demonstrated on normal human subjects on data collected using a novel fast, robust, and clinically feasible sPFG/dPFG acquisition. CONCLUSIONS The potential utility of this method is suggested by an initial demonstration of its ability to mitigate the problem of gyral bias. The capability of more completely characterizing the tissue structure and connectivity throughout the entire brain has broad implications for the utility and scope of dMRI in a wide range of research and clinical applications.
Collapse
Affiliation(s)
- Lawrence R Frank
- Center for Scientific Computation in Imaging, University of California at San Diego, La Jolla, CA, USA
- Center for Functional MRI, University of California at San Diego, La Jolla, CA, USA
| | | | - Vitaly L Galinsky
- Center for Scientific Computation in Imaging, University of California at San Diego, La Jolla, CA, USA
- Electrical and Computer Engineering Department, University of California at San Diego, La Jolla, CA, USA
| |
Collapse
|
8
|
Duchêne G, Abarca‐Quinones J, Leclercq I, Duprez T, Peeters F. Insights into tissue microstructure using a double diffusion encoding sequence on a clinical scanner: Validation and application to experimental tumor models. Magn Reson Med 2019; 83:1263-1276. [DOI: 10.1002/mrm.28012] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 09/03/2019] [Accepted: 09/05/2019] [Indexed: 12/15/2022]
Affiliation(s)
| | - Jorge Abarca‐Quinones
- Université Catholique de Louvain Brussels Belgium
- Cliniques Universitaires Saint‐Luc Brussels Belgium
| | - Isabelle Leclercq
- Université Catholique de Louvain Brussels Belgium
- Cliniques Universitaires Saint‐Luc Brussels Belgium
| | - Thierry Duprez
- Université Catholique de Louvain Brussels Belgium
- Cliniques Universitaires Saint‐Luc Brussels Belgium
| | | |
Collapse
|
9
|
Schilling KG, Daducci A, Maier-Hein K, Poupon C, Houde JC, Nath V, Anderson AW, Landman BA, Descoteaux M. Challenges in diffusion MRI tractography - Lessons learned from international benchmark competitions. Magn Reson Imaging 2019; 57:194-209. [PMID: 30503948 PMCID: PMC6331218 DOI: 10.1016/j.mri.2018.11.014] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 11/17/2018] [Indexed: 12/13/2022]
Abstract
Diffusion MRI (dMRI) fiber tractography has become a pillar of the neuroimaging community due to its ability to noninvasively map the structural connectivity of the brain. Despite widespread use in clinical and research domains, these methods suffer from several potential drawbacks or limitations. Thus, validating the accuracy and reproducibility of techniques is critical for sound scientific conclusions and effective clinical outcomes. Towards this end, a number of international benchmark competitions, or "challenges", has been organized by the diffusion MRI community in order to investigate the reliability of the tractography process by providing a platform to compare algorithms and results in a fair manner, and evaluate common and emerging algorithms in an effort to advance the state of the field. In this paper, we summarize the lessons from a decade of challenges in tractography, and give perspective on the past, present, and future "challenges" that the field of diffusion tractography faces.
Collapse
Affiliation(s)
- Kurt G Schilling
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States of America.
| | | | - Klaus Maier-Hein
- Division of Medical Image Computing, German Cancer Research Center (DKFZ), Heidelberg 69120, Germany
| | - Cyril Poupon
- Neurospin, Frédéric Joliot Life Sciences Institute, CEA, Gif-sur-Yvette, France
| | - Jean-Christophe Houde
- Sherbrooke Connectivity Imaging Lab (SCIL), Computer Science Department, Université de Sherbrooke, Québec, Canada
| | - Vishwesh Nath
- Electrical Engineering & Computer Science, Vanderbilt University, Nashville, TN, United States of America
| | - Adam W Anderson
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States of America; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States of America
| | - Bennett A Landman
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States of America; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, United States of America; Department of Electrical Engineering, Vanderbilt University, Nashville, TN, United States of America
| | - Maxime Descoteaux
- Sherbrooke Connectivity Imaging Lab (SCIL), Computer Science Department, Université de Sherbrooke, Québec, Canada
| |
Collapse
|
10
|
Novikov DS, Fieremans E, Jespersen SN, Kiselev VG. Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation. NMR IN BIOMEDICINE 2019; 32:e3998. [PMID: 30321478 PMCID: PMC6481929 DOI: 10.1002/nbm.3998] [Citation(s) in RCA: 264] [Impact Index Per Article: 52.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 06/11/2018] [Accepted: 06/28/2018] [Indexed: 05/18/2023]
Abstract
We review, systematize and discuss models of diffusion in neuronal tissue, by putting them into an overarching physical context of coarse-graining over an increasing diffusion length scale. From this perspective, we view research on quantifying brain microstructure as occurring along three major avenues. The first avenue focusses on transient, or time-dependent, effects in diffusion. These effects signify the gradual coarse-graining of tissue structure, which occurs qualitatively differently in different brain tissue compartments. We show that transient effects contain information about the relevant length scales for neuronal tissue, such as the packing correlation length for neuronal fibers, as well as the degree of structural disorder along the neurites. The second avenue corresponds to the long-time limit, when the observed signal can be approximated as a sum of multiple nonexchanging anisotropic Gaussian components. Here, the challenge lies in parameter estimation and in resolving its hidden degeneracies. The third avenue employs multiple diffusion encoding techniques, able to access information not contained in the conventional diffusion propagator. We conclude with our outlook on future directions that could open exciting possibilities for designing quantitative markers of tissue physiology and pathology, based on methods of studying mesoscopic transport in disordered systems.
Collapse
Affiliation(s)
- Dmitry S. Novikov
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, NY, USA
| | - Els Fieremans
- Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, NY, USA
| | - Sune N. Jespersen
- CFIN/MINDLab, Department of Clinical Medicine and Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark
| | - Valerij G. Kiselev
- Medical Physics, Deptartment of Radiology, Faculty of Medicine, University of Freiburg, Germany
| |
Collapse
|
11
|
Palombo M, Shemesh N, Ronen I, Valette J. Insights into brain microstructure from in vivo DW-MRS. Neuroimage 2018; 182:97-116. [DOI: 10.1016/j.neuroimage.2017.11.028] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2017] [Revised: 10/09/2017] [Accepted: 11/15/2017] [Indexed: 12/27/2022] Open
|
12
|
Komlosh ME, Benjamini D, Hutchinson EB, King S, Haber M, Avram AV, Holtzclaw LA, Desai A, Pierpaoli C, Basser PJ. Using double pulsed-field gradient MRI to study tissue microstructure in traumatic brain injury (TBI). MICROPOROUS AND MESOPOROUS MATERIALS : THE OFFICIAL JOURNAL OF THE INTERNATIONAL ZEOLITE ASSOCIATION 2018; 269:156-159. [PMID: 30337835 PMCID: PMC6188654 DOI: 10.1016/j.micromeso.2017.05.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Double pulsed-field gradient (dPFG) MRI is proposed as a new sensitive tool to detect and characterize tissue microstructure following diffuse axonal injury. In this study dPFG MRI was used to estimate apparent mean axon diameter in a diffuse axonal injury animal model and in healthy fixed mouse brain. Histological analysis was used to verify the presence of the injury detected by MRI.
Collapse
Affiliation(s)
- Michal E Komlosh
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
- Center for Neuroscience and Regenerative Medicine, Uniform Service University of the Health Sciences, Bethesda, MD, USA
| | - Dan Benjamini
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
| | - Elizabeth B Hutchinson
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
- Center for Neuroscience and Regenerative Medicine, Uniform Service University of the Health Sciences, Bethesda, MD, USA
| | - Sarah King
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
- Center for Neuroscience and Regenerative Medicine, Uniform Service University of the Health Sciences, Bethesda, MD, USA
| | - Margalit Haber
- Department of Neurology, University of Pennsylvania, Philadelphia, PA, USA
| | - Alexandru V Avram
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
| | - Lynne A Holtzclaw
- Microscopy and Imaging Core, NICHD, National Institutes of Health, Bethesda, MD, USA
| | - Abhishek Desai
- Laboratory of Molecular Signaling, NIAAA, National Institutes of Health, Rockville, MD, USA
| | - Carlo Pierpaoli
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
| | - Peter J Basser
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
13
|
Yang G, Tian Q, Leuze C, Wintermark M, McNab JA. Double diffusion encoding MRI for the clinic. Magn Reson Med 2017; 80:507-520. [PMID: 29266375 DOI: 10.1002/mrm.27043] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2017] [Revised: 11/17/2017] [Accepted: 11/18/2017] [Indexed: 12/13/2022]
Abstract
PURPOSE The purpose of this study is to develop double diffusion encoding (DDE) MRI methods for clinical use. Microscopic diffusion anisotropy measurements from DDE promise greater specificity to changes in tissue microstructure compared with conventional diffusion tensor imaging, but implementation of DDE sequences on whole-body MRI scanners is challenging because of the limited gradient strengths and lengthy acquisition times. METHODS A custom single-refocused DDE sequence was implemented on a 3T whole-body scanner. The DDE gradient orientation scheme and sequence parameters were optimized based on a Gaussian diffusion assumption. Using an optimized 5-min DDE acquisition, microscopic fractional anisotropy (μFA) maps were acquired for the first time in multiple sclerosis patients. RESULTS Based on simulations and in vivo human measurements, six parallel and six orthogonal diffusion gradient pairs were found to be the minimum number of diffusion gradient pairs necessary to produce a rotationally invariant measurement of μFA. Simulations showed that optimal precision and accuracy of μFA measurements were obtained using b-values between 1500 and 3000 s/mm2 . The μFA maps showed improved delineation of multiple sclerosis lesions compared with conventional fractional anisotropy and distinct contrast from T2 -weighted fluid attenuated inversion recovery and T1 -weighted imaging. CONCLUSION The μFA maps can be measured using DDE in a clinical setting and may provide new opportunities for characterizing multiple sclerosis lesions and other types of tissue degeneration. Magn Reson Med 80:507-520, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Grant Yang
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.,Department of Radiology, Stanford University, Stanford, California, USA
| | - Qiyuan Tian
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.,Department of Radiology, Stanford University, Stanford, California, USA
| | - Christoph Leuze
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Max Wintermark
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Jennifer A McNab
- Department of Radiology, Stanford University, Stanford, California, USA
| |
Collapse
|
14
|
Distinguishing neuronal from astrocytic subcellular microstructures using in vivo Double Diffusion Encoded 1H MRS at 21.1 T. PLoS One 2017; 12:e0185232. [PMID: 28968410 PMCID: PMC5624579 DOI: 10.1371/journal.pone.0185232] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 09/09/2017] [Indexed: 12/27/2022] Open
Abstract
Measuring cellular microstructures non-invasively and achieving specificity towards a cell-type population within an interrogated in vivo tissue, remains an outstanding challenge in brain research. Magnetic Resonance Spectroscopy (MRS) provides an opportunity to achieve cellular specificity via the spectral resolution of metabolites such as N-Acetylaspartate (NAA) and myo-Inositol (mI), which are considered neuronal and astrocytic markers, respectively. Yet the information typically obtained with MRS describes metabolic concentrations, diffusion coefficients or relaxation rates rather than microstructures. Understanding how these metabolites are compartmentalized is a challenging but important goal, which so far has been mainly addressed using diffusion models. Here, we present direct in vivo evidence for the confinement of NAA and mI within sub-cellular components, namely, the randomly oriented process of neurons and astrocytes, respectively. Our approach applied Relaxation Enhanced MRS at ultrahigh (21.1 T) field, and used its high 1H sensitivity to measure restricted diffusion correlations for NAA and mI using a Double Diffusion Encoding (DDE) filter. While very low macroscopic anisotropy was revealed by spatially localized Diffusion Tensor Spectroscopy, DDE displayed characteristic amplitude modulations reporting on confinements in otherwise randomly oriented anisotropic microstructures for both metabolites. This implies that for the chosen set of parameters, the DDE measurements had a biased sensitivity towards NAA and mI sited in the more confined environments of neurites and astrocytic branches, than in the cell somata. These measurements thus provide intrinsic diffusivities and compartment diameters, and revealed subcellular neuronal and astrocytic morphologies in normal in vivo rat brains. The relevance of these measurements towards human applications—which could in turn help understand CNS plasticity as well as diagnose brain diseases—is discussed.
Collapse
|
15
|
Shaw CB, Hui ES, Helpern JA, Jensen JH. Tensor estimation for double-pulsed diffusional kurtosis imaging. NMR IN BIOMEDICINE 2017; 30:e3722. [PMID: 28328072 DOI: 10.1002/nbm.3722] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Revised: 02/08/2017] [Accepted: 02/09/2017] [Indexed: 06/06/2023]
Abstract
Double-pulsed diffusional kurtosis imaging (DP-DKI) represents the double diffusion encoding (DDE) MRI signal in terms of six-dimensional (6D) diffusion and kurtosis tensors. Here a method for estimating these tensors from experimental data is described. A standard numerical algorithm for tensor estimation from conventional (i.e. single diffusion encoding) diffusional kurtosis imaging (DKI) data is generalized to DP-DKI. This algorithm is based on a weighted least squares (WLS) fit of the signal model to the data combined with constraints designed to minimize unphysical parameter estimates. The numerical algorithm then takes the form of a quadratic programming problem. The principal change required to adapt the conventional DKI fitting algorithm to DP-DKI is replacing the three-dimensional diffusion and kurtosis tensors with the 6D tensors needed for DP-DKI. In this way, the 6D diffusion and kurtosis tensors for DP-DKI can be conveniently estimated from DDE data by using constrained WLS, providing a practical means for condensing DDE measurements into well-defined mathematical constructs that may be useful for interpreting and applying DDE MRI. Data from healthy volunteers for brain are used to demonstrate the DP-DKI tensor estimation algorithm. In particular, representative parametric maps of selected tensor-derived rotational invariants are presented.
Collapse
Affiliation(s)
- Calvin B Shaw
- Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Edward S Hui
- Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong, SAR, China
| | - Joseph A Helpern
- Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Neuroscience, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Neurology, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Jens H Jensen
- Center for Biomedical Imaging, Medical University of South Carolina, Charleston, South Carolina, USA
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina, USA
| |
Collapse
|
16
|
Nilsson M, Lasič S, Drobnjak I, Topgaard D, Westin C. Resolution limit of cylinder diameter estimation by diffusion MRI: The impact of gradient waveform and orientation dispersion. NMR IN BIOMEDICINE 2017; 30:e3711. [PMID: 28318071 PMCID: PMC5485041 DOI: 10.1002/nbm.3711] [Citation(s) in RCA: 98] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 01/16/2017] [Accepted: 01/20/2017] [Indexed: 05/20/2023]
Abstract
Diffusion MRI has been proposed as a non-invasive technique for axonal diameter mapping. However, accurate estimation of small diameters requires strong gradients, which is a challenge for the transition of the technique from preclinical to clinical MRI scanners, since these have weaker gradients. In this work, we develop a framework to estimate the lower bound for accurate diameter estimation, which we refer to as the resolution limit. We analyse only the contribution from the intra-axonal space and assume that axons can be represented by impermeable cylinders. To address the growing interest in using techniques for diffusion encoding that go beyond the conventional single diffusion encoding (SDE) sequence, we present a generalised analysis capable of predicting the resolution limit regardless of the gradient waveform. Using this framework, waveforms were optimised to minimise the resolution limit. The results show that, for parallel cylinders, the SDE experiment is optimal in terms of yielding the lowest possible resolution limit. In the presence of orientation dispersion, diffusion encoding sequences with square-wave oscillating gradients were optimal. The resolution limit for standard clinical MRI scanners (maximum gradient strength 60-80 mT/m) was found to be between 4 and 8 μm, depending on the noise levels and the level of orientation dispersion. For scanners with a maximum gradient strength of 300 mT/m, the limit was reduced to between 2 and 5 μm.
Collapse
Affiliation(s)
- Markus Nilsson
- Clinical Sciences Lund, Department of RadiologyLund UniversityLundSweden
| | | | | | - Daniel Topgaard
- Division of Physical Chemistry, Department of ChemistryLund UniversityLundSweden
| | - Carl‐Fredrik Westin
- Department of Biomedical EngineeringLinköping UniversityLinköpingSweden
- Brigham and Women's HospitalHarvard Medical SchoolBostonMAUSA
| |
Collapse
|
17
|
Benjamini D, Komlosh ME, Basser PJ. Imaging Local Diffusive Dynamics Using Diffusion Exchange Spectroscopy MRI. PHYSICAL REVIEW LETTERS 2017; 118:158003. [PMID: 28452522 PMCID: PMC11079612 DOI: 10.1103/physrevlett.118.158003] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Indexed: 06/07/2023]
Abstract
The movement of water between microenvironments presents a central challenge in the physics of soft matter and porous media. Diffusion exchange spectroscopy (DEXSY) is a powerful 2D nuclear magnetic resonance method for measuring such exchange, yet it is rarely used because of its long scan time requirements. Moreover, it has never been combined with magnetic resonance imaging (MRI). Using probability theory, we vastly reduce the required data, making DEXSY MRI feasible for the first time. Experiments are performed on a composite nerve tissue phantom with restricted and free water-exchanging compartments.
Collapse
Affiliation(s)
- Dan Benjamini
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, Maryland 20892, USA
| | - Michal E. Komlosh
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, Maryland 20892, USA
- Center for Neuroscience and Regenerative Medicine, Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, Maryland 20892, USA
| | - Peter J. Basser
- Section on Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, Maryland 20892, USA
| |
Collapse
|
18
|
Ianuş A, Shemesh N, Alexander DC, Drobnjak I. Double oscillating diffusion encoding and sensitivity to microscopic anisotropy. Magn Reson Med 2016; 78:550-564. [PMID: 27580027 PMCID: PMC5516160 DOI: 10.1002/mrm.26393] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2016] [Revised: 07/05/2016] [Accepted: 07/31/2016] [Indexed: 12/13/2022]
Abstract
Purpose To introduce a novel diffusion pulse sequence, namely double oscillating diffusion encoding (DODE), and to investigate whether it adds sensitivity to microscopic diffusion anisotropy (µA) compared to the well‐established double diffusion encoding (DDE) methodology. Methods We simulate measurements from DODE and DDE sequences for different types of microstructures exhibiting restricted diffusion. First, we compare the effect of varying pulse sequence parameters on the DODE and DDE signal. Then, we analyse the sensitivity of the two sequences to the microstructural parameters (pore diameter and length) which determine µA. Finally, we investigate specificity of measurements to particular substrate configurations. Results Simulations show that DODE sequences exhibit similar signal dependence on the relative angle between the two gradients as DDE sequences, however, the effect of varying the mixing time is less pronounced. The sensitivity analysis shows that in substrates with elongated pores and various orientations, DODE sequences increase the sensitivity to pore diameter, while DDE sequences are more sensitive to pore length. Moreover, DDE and DODE sequence parameters can be tailored to enhance/suppress the signal from a particular range of substrates. Conclusions A combination of DODE and DDE sequences maximize sensitivity to µA, compared to using just the DDE method. Magn Reson Med 78:550–564, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
Affiliation(s)
- Andrada Ianuş
- Centre for Medical Image Computing, University College London, London, UK
| | - Noam Shemesh
- Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown, Lisbon, Portugal
| | - Daniel C Alexander
- Centre for Medical Image Computing, University College London, London, UK
| | - Ivana Drobnjak
- Centre for Medical Image Computing, University College London, London, UK
| |
Collapse
|
19
|
Ianuş A, Drobnjak I, Alexander DC. Model-based estimation of microscopic anisotropy using diffusion MRI: a simulation study. NMR IN BIOMEDICINE 2016; 29:672-685. [PMID: 27003223 DOI: 10.1002/nbm.3496] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Revised: 01/04/2016] [Accepted: 01/06/2016] [Indexed: 06/05/2023]
Abstract
Non-invasive estimation of cell size and shape is a key challenge in diffusion MRI. This article presents a model-based approach that provides independent estimates of pore size and eccentricity from diffusion MRI data. The technique uses a geometric model of finite cylinders with gamma-distributed radii to represent pores of various sizes and elongations. We consider both macroscopically isotropic substrates and substrates of semi-coherently oriented anisotropic pores and we use Monte Carlo simulations to generate synthetic data. We compare the sensitivity of single and double diffusion encoding (SDE and DDE) sequences to the size distribution and eccentricity, and further analyse different protocols of DDE sequences with parallel and/or perpendicular pairs of gradients. We show that explicitly accounting for size distribution is necessary for accurate microstructural parameter estimates, and a model that assumes a single size yields biased eccentricity values. We also find that SDE sequences support estimates, although DDE sequences with mixed parallel and perpendicular gradients enhance accuracy. In the case of macroscopically anisotropic substrates, this model-based approach can be extended to a rotationally invariant framework to provide features of pore shape (specifically eccentricity) in the presence of size distribution and orientation dispersion.
Collapse
Affiliation(s)
- Andrada Ianuş
- Center for Medical Image Computing, Department of Computer Science, University College London, UK
| | - Ivana Drobnjak
- Center for Medical Image Computing, Department of Computer Science, University College London, UK
| | - Daniel C Alexander
- Center for Medical Image Computing, Department of Computer Science, University College London, UK
| |
Collapse
|
20
|
Benjamini D, Komlosh ME, Holtzclaw LA, Nevo U, Basser PJ. White matter microstructure from nonparametric axon diameter distribution mapping. Neuroimage 2016; 135:333-44. [PMID: 27126002 DOI: 10.1016/j.neuroimage.2016.04.052] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 03/18/2016] [Accepted: 04/21/2016] [Indexed: 12/31/2022] Open
Abstract
We report the development of a double diffusion encoding (DDE) MRI method to estimate and map the axon diameter distribution (ADD) within an imaging volume. A variety of biological processes, ranging from development to disease and trauma, may lead to changes in the ADD in the central and peripheral nervous systems. Unlike previously proposed methods, this ADD experimental design and estimation framework employs a more general, nonparametric approach, without a priori assumptions about the underlying form of the ADD, making it suitable to analyze abnormal tissue. In the current study, this framework was used on an ex vivo ferret spinal cord, while emphasizing the way in which the ADD can be weighted by either the number or the volume of the axons. The different weightings, which result in different spatial contrasts, were considered throughout this work. DDE data were analyzed to derive spatially resolved maps of average axon diameter, ADD variance, and extra-axonal volume fraction, along with a novel sub-micron restricted structures map. The morphological information contained in these maps was then used to segment white matter into distinct domains by using a proposed k-means clustering algorithm with spatial contiguity and left-right symmetry constraints, resulting in identifiable white matter tracks. The method was validated by comparing histological measures to the estimated ADDs using a quantitative similarity metric, resulting in good agreement. With further acquisition acceleration and experimental parameters adjustments, this ADD estimation framework could be first used preclinically, and eventually clinically, enabling a wide range of neuroimaging applications for improved understanding of neurodegenerative pathologies and assessing microstructural changes resulting from trauma.
Collapse
Affiliation(s)
- Dan Benjamini
- Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD 20892, USA; Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel.
| | - Michal E Komlosh
- Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD 20892, USA; Center for Neuroscience and Regenerative Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA
| | - Lynne A Holtzclaw
- Microscopy & Imaging Core, NICHD, National Institutes of Health, Bethesda, MD 20892, USA
| | - Uri Nevo
- Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel
| | - Peter J Basser
- Quantitative Imaging and Tissue Sciences, NICHD, National Institutes of Health, Bethesda, MD 20892, USA
| |
Collapse
|
21
|
Skinner NP, Kurpad SN, Schmit BD, Tugan Muftuler L, Budde MD. Rapid in vivo detection of rat spinal cord injury with double-diffusion-encoded magnetic resonance spectroscopy. Magn Reson Med 2016; 77:1639-1649. [PMID: 27080726 DOI: 10.1002/mrm.26243] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Revised: 03/04/2016] [Accepted: 03/27/2016] [Indexed: 11/07/2022]
Abstract
PURPOSE Diffusion-weighted imaging is a common experimental tool for evaluating spinal cord injury (SCI), yet it suffers from complications that decrease its clinical effectiveness. The most commonly used technique, diffusion tensor imaging (DTI), is often confounded by effects of edema accompanying acute SCI, limiting its sensitivity to the important functional status marker of axonal integrity. The purpose of this study is to introduce a novel diffusion-acquisition method with the goal of overcoming these limitations. METHODS A double diffusion encoding (DDE) pulse sequence was implemented with a diffusion-weighted filter orthogonal to the spinal cord for suppressing nonneural signals prior to diffusion weighting parallel to the cord. A point-resolved spectroscopy readout (DDE-PRESS) was used for improved sensitivity and compared with DTI in a rat model of SCI with varying injury severities. RESULTS The DDE-PRESS parameter, restricted fraction, showed a strong relationship with injury severity (P < 0.001, R2 = 0.67). Although the whole-cord averaged DTI parameter values exhibited only minor injury relationships, a weighted region of interest (ROI) based DTI analysis improved sensitivity to injury (P < 0.001, R2 = 0.66). CONCLUSIONS In a rat model of SCI, DDE-PRESS demonstrated high sensitivity to injury with substantial decreases in acquisition time and data processing. This method shows promise for application in rapid evaluation of SCI severity. Magn Reson Med 77:1639-1649, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Nathan P Skinner
- Biophysics Graduate Program, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.,Dept. of Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Shekar N Kurpad
- Dept. of Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Brian D Schmit
- Dept. of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin, USA
| | - L Tugan Muftuler
- Dept. of Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Matthew D Budde
- Dept. of Neurosurgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| |
Collapse
|
22
|
Xu J, Li H, Li K, Harkins KD, Jiang X, Xie J, Kang H, Dortch RD, Anderson AW, Does MD, Gore JC. Fast and simplified mapping of mean axon diameter using temporal diffusion spectroscopy. NMR IN BIOMEDICINE 2016; 29:400-410. [PMID: 27077155 PMCID: PMC4832578 DOI: 10.1002/nbm.3484] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Mapping axon diameter is of interest for the potential diagnosis and monitoring of various neuronal pathologies. Advanced diffusion-weighted MRI methods have been developed to measure mean axon diameters non-invasively, but suffer major drawbacks that prevent their direct translation into clinical practice, such as complex non-linear data fitting and, more importantly, long scanning times that are usually not tolerable for most human subjects. In the current study, temporal diffusion spectroscopy using oscillating diffusion gradients was used to measure mean axon diameters with high sensitivity to small axons in the central nervous system. Axon diameters have been found to be correlated with a novel metric, DDR⊥ (the rate of dispersion of the perpendicular diffusion coefficient with gradient frequency), which is a model-free quantity that does not require complex data analyses and can be obtained from two diffusion coefficient measurements in clinically relevant times with conventional MRI machines. A comprehensive investigation including computer simulations and animal experiments ex vivo showed that measurements of DDR⊥ agree closely with histological data. In humans in vivo, DDR⊥ was also found to correlate well with reported mean axon diameters in human corpus callosum, and the total scan time was only about 8 min. In conclusion, DDR⊥ may have potential to serve as a fast, simple and model-free approach to map the mean axon diameter of white matter in clinics for assessing axon diameter changes.
Collapse
Affiliation(s)
- Junzhong Xu
- Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA; Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Mueller L, Wetscherek A, Kuder TA, Laun FB. Eddy current compensated double diffusion encoded (DDE) MRI. Magn Reson Med 2015; 77:328-335. [PMID: 26715361 DOI: 10.1002/mrm.26092] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Revised: 11/06/2015] [Accepted: 11/24/2015] [Indexed: 11/07/2022]
Abstract
PURPOSE Eddy currents might lead to image distortions in diffusion-weighted echo planar imaging. A method is proposed to reduce their effects on double diffusion encoding (DDE) MRI experiments and the thereby derived microscopic fractional anisotropy (μFA). METHODS The twice-refocused spin echo scheme was adapted for DDE measurements. To assess the effect of individual diffusion encodings on the image distortions, measurements of a grid of plastic rods in water were performed. The effect of eddy current compensation on μFA measurements was evaluated in the brains of six healthy volunteers. RESULTS The use of an eddy current compensation reduced the signal variation. As expected, the distortions caused by the second encoding were larger than those of the first encoding, entailing a stronger need to compensate for them. For an optimal result, however, both encodings had to be compensated. The artifact reduction strongly improved the measurement of the μFA in ventricles and gray matter by reducing the overestimation. An effect of the compensation on absolute μFA values in white matter was not observed. CONCLUSION It is advisable to compensate both encodings in DDE measurements for eddy currents. Magn Reson Med 77:328-335, 2017. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Lars Mueller
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Andreas Wetscherek
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Tristan Anselm Kuder
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Frederik Bernd Laun
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
24
|
Shemesh N, Jespersen SN, Alexander DC, Cohen Y, Drobnjak I, Dyrby TB, Finsterbusch J, Koch MA, Kuder T, Laun F, Lawrenz M, Lundell H, Mitra PP, Nilsson M, Özarslan E, Topgaard D, Westin CF. Conventions and nomenclature for double diffusion encoding NMR and MRI. Magn Reson Med 2015; 75:82-7. [DOI: 10.1002/mrm.25901] [Citation(s) in RCA: 140] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Revised: 07/13/2015] [Accepted: 07/29/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Noam Shemesh
- Champalimaud Neuroscience Programme, Champalimaud Centre for the Unknown; Lisbon Portugal
| | - Sune N. Jespersen
- CFIN/MindLab, Aarhus University; Aarhus Denmark
- Department of Physics and Astronomy; Aarhus University; Aarhus Denmark
| | - Daniel C. Alexander
- Centre for Medical Image Computing, Department of Computer Science, University College London; London United Kingdom
| | - Yoram Cohen
- School of Chemistry, the Raymond and Beverly Sackler Faculty of Exact Sciences; Tel Aviv University; Tel Aviv Israel
- Sagol School of Neurosciences; Tel Aviv University; Tel Aviv Israel
| | - Ivana Drobnjak
- Centre for Medical Image Computing, Department of Computer Science, University College London; London United Kingdom
| | - Tim B. Dyrby
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre; Hvidovre Denmark
| | - Jurgen Finsterbusch
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
- Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck; Germany
| | - Martin A. Koch
- Institute of Medical Engineering; University of Lübeck; Lübeck Germany
| | - Tristan Kuder
- Medical Physics in Radiology, German Cancer Research Center; Im Neuenheimer Feld 280 Heidelberg Germany
| | - Fredrik Laun
- Medical Physics in Radiology, German Cancer Research Center; Im Neuenheimer Feld 280 Heidelberg Germany
| | - Marco Lawrenz
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
| | - Henrik Lundell
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre; Hvidovre Denmark
| | - Partha P. Mitra
- Cold Spring Harbor Laboratory; Cold Spring Harbor New York USA
| | - Markus Nilsson
- Lund University Bioimaging Center, Lund University; Lund Sweden
| | - Evren Özarslan
- Department of Physics; Boğaziçi University; Bebek Istanbul Turkey
| | - Daniel Topgaard
- Division of Physical Chemistry, Department of Chemistry; Lund University; Lund Sweden
| | - Carl-Fredrik Westin
- Department of Radiology, Brigham and Women's Hospital; Harvard Medical School; Boston Massachusetts USA
| |
Collapse
|
25
|
Berl MM, Walker L, Modi P, Irfanoglu MO, Sarlls JE, Nayak A, Pierpaoli C. Investigation of vibration-induced artifact in clinical diffusion-weighted imaging of pediatric subjects. Hum Brain Mapp 2015; 36:4745-57. [PMID: 26350492 DOI: 10.1002/hbm.22846] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 05/04/2015] [Accepted: 05/08/2015] [Indexed: 11/07/2022] Open
Abstract
It has been reported that mechanical vibrations of the magnetic resonance imaging scanner could produce spurious signal dropouts in diffusion-weighted images resulting in artifactual anisotropy in certain regions of the brain with red appearance in the Directionally Encoded Color maps. We performed a review of the frequency of this artifact across pediatric studies, noting differences by scanner manufacturer, acquisition protocol, as well as weight and position of the subject. We also evaluated the ability of automated and quantitative methods to detect this artifact. We found that the artifact may be present in over 50% of data in certain protocols and is not limited to one scanner manufacturer. While a specific scanner had the highest incidence, low body weight and positioning were also associated with appearance of the artifact for both scanner types evaluated, making children potentially more susceptible than adults. Visual inspection remains the best method for artifact identification. Software for automated detection showed very low sensitivity (10%). The artifact may present inconsistently in longitudinal studies. We discuss a published case report that has been widely cited and used as evidence to set policy about diagnostic criteria for determining vegetative state. That report attributed longitudinal changes in anisotropy to white matter plasticity without considering the possibility that the changes were caused by this artifact. Our study underscores the need to check for the presence of this artifact in clinical studies, analyzes circumstances for when it may be more likely to occur, and suggests simple strategies to identify and potentially avoid its effects.
Collapse
Affiliation(s)
- Madison M Berl
- Division of Pediatric Neuropsychology, Washington, District of Columbia, Children's Research Institute, Children's National Health System, Washington, DC
| | - Lindsay Walker
- Program on Pediatric Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD
| | - Pooja Modi
- Program on Pediatric Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD
| | - M Okan Irfanoglu
- Program on Pediatric Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD.,Henry Jackson Foundation, Bethesda, Maryland
| | - Joelle E Sarlls
- NMRF, NINDS, National Institutes of Health, Bethesda, Maryland
| | - Amritha Nayak
- Program on Pediatric Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD.,Henry Jackson Foundation, Bethesda, Maryland
| | - Carlo Pierpaoli
- Program on Pediatric Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD.,Center for Neuroscience and Regenerative Medicine, Uniformed Services University of the Health Sciences, Bethesda, Maryland
| |
Collapse
|
26
|
Studying the extracellular contribution to the double wave vector diffusion-weighted signal. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2015. [DOI: 10.1515/cdbme-2015-0060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
AbstractThe use of two independent diffusion periods between excitation and acquisition, known as double wave vector (DWV) diffusion-weighting or double diffusion encoding, was proven to yield structural information that it is otherwise not easily available in vivo. Comparing the signal difference between relative diffusion gradient orientations, the antiparallel-parallel and the parallel-perpendicular differences yield information on pore size and shape, respectively. However, results in vivo provided larger pore sizes than expected for axons in the corticospinal tract. This study exploits DWV sensitivity to pore shape and aims to obtain information on the extracellular contributions to the DWV pore size results presented here. The in vivo DWV experiments resulted in a positive parallel-perpendicular difference which is consistent with an irregularly shaped pore dominating the origin of the signal.
Collapse
|
27
|
Lawrenz M, Brassen S, Finsterbusch J. Microscopic diffusion anisotropy in the human brain: reproducibility, normal values, and comparison with the fractional anisotropy. Neuroimage 2015; 109:283-97. [PMID: 25595503 DOI: 10.1016/j.neuroimage.2015.01.025] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 01/05/2015] [Accepted: 01/06/2015] [Indexed: 11/28/2022] Open
Abstract
Human neuroimaging of tissue microstructure, such as axonal density and integrity, is key in clinical and neuroscience research. Most studies rely on diffusion tensor imaging (DTI) and the measures derived from it, most prominently fractional anisotropy (FA). However, FA also depends on fiber orientation distribution, a more macroscopic tissue property. Recently introduced measures of so-called microscopic diffusion anisotropy, diffusion anisotropy on a cellular or microscopic level, overcome this limitation because they are independent of the orientation distributions of axons and fibers. In this study, we evaluate the feasibility of two measures of microscopic diffusion anisotropy I(MA) and MA indices, for human neuroscience and clinical research. Both indices reflect the eccentricity of the cells but while I(MA) also depends on the cell size, MA is independent of the cell size and, like FA, scaled between 0 and 1. In whole-brain measurements of a group of 19 healthy volunteers, we measured average values and variability, evaluated their reproducibility, both within and between sessions, and compared MA to FA values in selected regions-of-interest (ROIs). The within- and between-session comparison did not show substantial differences but the reproducibility was much better for the MA than I(MA) (coefficient of variation between sessions 10.5% vs. 28.9%). The reproducibility was less for MA than FA overall, but comparable in the defined ROIs and the average group sizes required for between-group comparisons was similar (about 60 participants for a relative difference of 5%). Group-averaged values of MA index were generally larger and showed less variation across white-matter brain ROIs than FA (mean ± standard deviation of seven ROIs 0.83 ± 0.10 vs. 0.58 ± 0.13). Even in some gray-matter ROIs, MA values comparable to those of white matter ROIs were observed. Furthermore, the within-group variation of the values in white matter ROIs was lower for the MA compared to the FA (mean standard deviation over volunteers 0.038 vs. 0.049) which could be due to significant variability in the distribution of fiber orientation contributing to FA. These results indicate that MA (i) should be preferred to I(MA), (ii) has a reproducibility and group-size requirements comparable to those of FA; (iii) is less sensitive to the fiber orientation distribution than FA; and (iv) could be more sensitive to differences or changes of the tissue microstructure than FA. R1.1.
Collapse
Affiliation(s)
- Marco Lawrenz
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany
| | - Stefanie Brassen
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany
| | - Jürgen Finsterbusch
- Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Neuroimage Nord, University Medical Centers Hamburg-Kiel-Lübeck, Germany.
| |
Collapse
|
28
|
Paulsen JL, Song YQ. Two-dimensional diffusion time correlation experiment using a single direction gradient. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 244:6-11. [PMID: 24819424 DOI: 10.1016/j.jmr.2014.04.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 04/08/2014] [Accepted: 04/10/2014] [Indexed: 06/03/2023]
Abstract
The time dependence of the diffusion coefficient is a well known property of porous media and commonly obtained by pulsed field gradient (PFG) NMR. In practical materials, its analysis can be complicated by the presence of a broad pore size distribution and multiple fluid phases with different diffusion coefficients. We propose a two-dimensional Diffusion Time Correlation experiment (DTC), which utilizes the double-PFG with a single-direction gradient to yield a two-dimensional correlation function of the diffusion coefficient for two different diffusion times. This correlation map separates out restricted diffusion from the bulk diffusion process and we demonstrate this on a plant and bulk water sample. In its development, we show that the d-PFG should then be thought of as correlating two apparent diffusion coefficients measured by two overlapping gradient waveforms.
Collapse
Affiliation(s)
| | - Yi-Qiao Song
- Schlumberger-Doll Research Cambridge, MA 02139, United States
| |
Collapse
|
29
|
Lawrenz M, Finsterbusch J. Mapping measures of microscopic diffusion anisotropy in human brain white matter in vivo with double-wave-vector diffusion-weighted imaging. Magn Reson Med 2014; 73:773-83. [DOI: 10.1002/mrm.25140] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2013] [Revised: 12/12/2013] [Accepted: 01/02/2014] [Indexed: 11/07/2022]
Affiliation(s)
- Marco Lawrenz
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
- Neuroimage Nord; University Medical Centers Hamburg-Kiel-Lübeck; Germany
| | - Jürgen Finsterbusch
- Department of Systems Neuroscience; University Medical Center Hamburg-Eppendorf; Hamburg Germany
- Neuroimage Nord; University Medical Centers Hamburg-Kiel-Lübeck; Germany
| |
Collapse
|
30
|
Jespersen SN, Lundell H, Sønderby CK, Dyrby TB. Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments. NMR IN BIOMEDICINE 2013; 26:1647-1662. [PMID: 24038641 DOI: 10.1002/nbm.2999] [Citation(s) in RCA: 139] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2013] [Revised: 06/11/2013] [Accepted: 06/13/2013] [Indexed: 06/02/2023]
Abstract
Pulsed field gradient diffusion sequences (PFG) with multiple diffusion encoding blocks have been indicated to offer new microstructural tissue information, such as the ability to detect nonspherical compartment shapes in macroscopically isotropic samples, i.e. samples with negligible directional signal dependence on diffusion gradients in standard diffusion experiments. However, current acquisition schemes are not rotationally invariant in the sense that the derived metrics depend on the orientation of the sample, and are affected by the interplay of sampling directions and compartment orientation dispersion when applied to macroscopically anisotropic systems. Here we propose a new framework, the d-PFG 5-design, to enable rotationally invariant estimation of double wave vector diffusion metrics (d-PFG). The method is based on the idea that an appropriate orientational average of the signal emulates the signal from a powder preparation of the same sample, where macroscopic anisotropy is absent by construction. Our approach exploits the theory of exact numerical integration (quadrature) of polynomials on the rotation group, and we exemplify the general procedure with a set consisting of 60 pairs of diffusion wave vectors (the d-PFG 5-design) facilitating a theoretically exact determination of the fourth order Taylor or cumulant expansion of the orientationally averaged signal. The d-PFG 5-design is evaluated with numerical simulations and ex vivo high field diffusion MRI experiments in a nonhuman primate brain. Specifically, we demonstrate rotational invariance when estimating compartment eccentricity, which we show offers new microstructural information, complementary to that of fractional anisotropy (FA) from diffusion tensor imaging (DTI). The imaging observations are supported by a new theoretical result, directly relating compartment eccentricity to FA of individual pores.
Collapse
Affiliation(s)
- Sune Nørhøj Jespersen
- Center of Functionally Integrative Neuroscience (CFIN) and MINDLab, Clinical Institute, Aarhus University, Aarhus, Denmark; Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark
| | | | | | | |
Collapse
|
31
|
Benjamini D, Nevo U. Estimation of pore size distribution using concentric double pulsed-field gradient NMR. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2013; 230:198-204. [PMID: 23548563 DOI: 10.1016/j.jmr.2013.03.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 02/22/2013] [Accepted: 03/01/2013] [Indexed: 06/02/2023]
Abstract
Estimation of pore size distribution of well calibrated phantoms using NMR is demonstrated here for the first time. Porous materials are a central constituent in fields as diverse as biology, geology, and oil drilling. Noninvasive characterization of monodisperse porous samples using conventional pulsed-field gradient (PFG) NMR is a well-established method. However, estimation of pore size distribution of heterogeneous polydisperse systems, which comprise most of the materials found in nature, remains extremely challenging. Concentric double pulsed-field gradient (CDPFG) is a 2-D technique where both q (the amplitude of the diffusion gradient) and φ (the relative angle between the gradient pairs) are varied. A recent prediction indicates this method should produce a more accurate and robust estimation of pore size distribution than its conventional 1-D versions. Five well defined size distribution phantoms, consisting of 1-5 different pore sizes in the range of 5-25 μm were used. The estimated pore size distributions were all in good agreement with the known theoretical size distributions, and were obtained without any a priori assumption on the size distribution model. These findings support that in addition to its theoretical benefits, the CDPFG method is experimentally reliable. Furthermore, by adding the angle parameter, sensitivity to small compartment sizes is increased without the use of strong gradients, thus making CDPFG safe for biological applications.
Collapse
Affiliation(s)
- Dan Benjamini
- Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel
| | | |
Collapse
|
32
|
Morozov D, Bar L, Sochen N, Cohen Y. Measuring small compartments with relatively weak gradients by angular double-pulsed-field-gradient NMR. Magn Reson Imaging 2013; 31:401-7. [DOI: 10.1016/j.mri.2012.08.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2012] [Accepted: 08/31/2012] [Indexed: 11/30/2022]
|
33
|
Bourne R. Magnetic resonance microscopy of prostate tissue: How basic science can inform clinical imaging development. J Med Radiat Sci 2013; 60:5-10. [PMID: 26229601 PMCID: PMC4175794 DOI: 10.1002/jmrs.3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2012] [Accepted: 12/05/2012] [Indexed: 12/26/2022] Open
Abstract
This commentary outlines how magnetic resonance imaging (MRI) microscopy studies of prostate tissue samples and whole organs have shed light on a number of clinical imaging mysteries and may enable more effective development of new clinical imaging methods.
Collapse
Affiliation(s)
- Roger Bourne
- Discipline of Medical Radiation Sciences, Faculty of Health Sciences, The University of Sydney Sydney, New South Wales 2006, Australia
| |
Collapse
|
34
|
Avram AV, Özarslan E, Sarlls JE, Basser PJ. In vivo detection of microscopic anisotropy using quadruple pulsed-field gradient (qPFG) diffusion MRI on a clinical scanner. Neuroimage 2013; 64:229-39. [PMID: 22939872 PMCID: PMC3520437 DOI: 10.1016/j.neuroimage.2012.08.048] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Revised: 08/02/2012] [Accepted: 08/18/2012] [Indexed: 11/20/2022] Open
Abstract
We report our design and implementation of a quadruple pulsed-field gradient (qPFG) diffusion MRI pulse sequence on a whole-body clinical scanner and demonstrate its ability to non-invasively detect restriction-induced microscopic anisotropy in human brain tissue. The microstructural information measured using qPFG diffusion MRI in white matter complements that provided by diffusion tensor imaging (DTI) and exclusively characterizes diffusion of water trapped in microscopic compartments with unique measures of average cell geometry. We describe the effect of white matter fiber orientation on the expected MR signal and highlight the importance of incorporating such information in the axon diameter measurement using a suitable mathematical framework. Integration of qPFG diffusion-weighted images (DWI) with fiber orientations measured using high-resolution DTI allows the estimation of average axon diameters in the corpus callosum of healthy human volunteers. Maps of inter-hemispheric average axon diameters reveal an anterior-posterior variation in good topographical agreement with anatomical measurements reported in previous post-mortem studies. With further technical refinements and additional clinical validation, qPFG diffusion MRI could provide a quantitative whole-brain histological assessment of white and gray matter, enabling a wide range of neuroimaging applications for improved diagnosis of neurodegenerative pathologies, monitoring neurodevelopmental processes, and mapping brain connectivity.
Collapse
Affiliation(s)
- Alexandru V Avram
- Section on Tissue Biophysics and Biomimetics, PPITS, NICHD, National Institutes of Health, Bethesda, MD 20892, USA.
| | | | | | | |
Collapse
|
35
|
Lawrenz M, Finsterbusch J. Double-wave-vector diffusion-weighted imaging reveals microscopic diffusion anisotropy in the living human brain. Magn Reson Med 2012; 69:1072-82. [DOI: 10.1002/mrm.24347] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2012] [Revised: 04/27/2012] [Accepted: 04/30/2012] [Indexed: 11/05/2022]
|
36
|
Jespersen SN. Equivalence of double and single wave vector diffusion contrast at low diffusion weighting. NMR IN BIOMEDICINE 2012; 25:813-818. [PMID: 22134913 DOI: 10.1002/nbm.1808] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2011] [Revised: 09/28/2011] [Accepted: 10/07/2011] [Indexed: 05/31/2023]
Abstract
Multiple pulsed field gradient diffusion sequences have received renewed interest in recent years as a potentially new type of MRI contrast. This attention is largely a result of the ability to measure pore sizes using low-amplitude diffusion gradients, and to distinguish between macroscopically isotropic systems of anisotropic pores and systems of isotropic pores. In this article, it is shown that, under many circumstances, the same type of information can be obtained by combining two or more standard single pulse diffusion-weighted experiments acquired at different diffusion times. Similarly, information from multiple pulsed field gradient diffusion can be reconstructed from several single pulsed diffusion experiments. This possibility is rooted in the information contained in the time dependence of the diffusion tensor, which provides a complete description of the diffusion-weighted MR signal at low gradient amplitudes. The new information arising at the fourth order in the cumulant expansion is discussed. The coupling of the wave vectors at long mixing times is found to be controlled by the variance of the single pore mean displacement tensor. In particular, a discussion is given concerning the way in which the sensitivity of the fourth-order term to the pore shape anisotropy is modulated by pore orientation anisotropy and vanishes in coherently oriented homogeneous ensembles. For macroscopically isotropic systems, a new index of pore shape anisotropy is proposed.
Collapse
Affiliation(s)
- Sune Nørhøj Jespersen
- Center of Functionally Integrative Neuroscience/MINDLab, Aarhus University, Aarhus, Denmark.
| |
Collapse
|