1
|
Hui SC, Zöllner HJ, Gong T, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS perform similarly at revealing metabolite-age correlations at 3 T. Magn Reson Med 2024; 91:431-442. [PMID: 37876339 PMCID: PMC10942734 DOI: 10.1002/mrm.29895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 10/03/2023] [Accepted: 10/04/2023] [Indexed: 10/26/2023]
Abstract
PURPOSE To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate at 3 T. METHODS MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale and posterior cingulate cortex (PCC). Acquisition parameters included TR/TE = 2000/30 ms, 96 transients, and 2048 datapoints sampled at 2 kHz. Spectra were analyzed using Osprey. SNR, FWHM linewidth of total creatine, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. RESULTS SNR and linewidth were significantly higher (p < 0.01) for sLASER than PRESS in PCC. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. PRESS-sLASER measurements were significantly correlated (p < 0.05) for most metabolites. Metabolite-age relationships were consistently identified using both methods. Similar coefficients of variation were observed for most metabolites. CONCLUSION The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in centrum semiovale and PCC data acquired at 3 T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in homogeneous brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- Developing Brain Institute, Children’s National Hospital, Washington, DC, USA
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
2
|
Reitlo LS, Mihailovic JM, Stensvold D, Wisløff U, Hyder F, Håberg AK. Hippocampal neurochemicals are associated with exercise group and intensity, psychological health, and general cognition in older adults. GeroScience 2023; 45:1667-1685. [PMID: 36626020 PMCID: PMC10400748 DOI: 10.1007/s11357-022-00719-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 12/24/2022] [Indexed: 01/11/2023] Open
Abstract
Based on the premise that physical activity/exercise impacts hippocampal structure and function, we investigated if hippocampal metabolites for neuronal viability and cell membrane density (i.e., N-acetyl aspartate (NAA), choline (Cho), creatine (Cr)) were higher in older adults performing supervised exercise compared to following national physical activity guidelines. Sixty-three participants (75.3 ± 1.9 years after 3 years of intervention) recruited from the Generation 100 study (NCT01666340_date:08.16.2012) were randomized into a supervised exercise group (SEG) performing twice weekly moderate- to high-intensity training, and a control group (CG) following national physical activity guidelines of ≥ 30-min moderate physical activity ≥ 5 days/week. Hippocampal body and head volumes and NAA, Cho, and Cr levels were acquired at 3T with magnetic resonance imaging and spectroscopic imaging. Sociodemographic data, peak oxygen uptake (VO2peak), exercise characteristics, psychological health, and cognition were recorded. General linear models were used to assess group differences and associations corrected for age, sex, education, and hippocampal volume. Both groups adhered to their training, where SEG trained at higher intensity. SEG had significantly lower NAA/Cr in hippocampal body than CG (p = 0.04). Across participants, higher training intensity was associated with lower Cho/Cr in hippocampal body (p < 0.001). Change in VO2peak, increasing VO2peak from baseline to 3 years, or VO2peak at 3 years were not associated with hippocampal neurochemicals. Lower NAA/Cr in hippocampal body was associated with poorer psychological health and slightly higher cognitive scores. Thus, following the national physical activity guidelines and not training at the highest intensity level were associated with the best neurochemical profile in the hippocampus at 3 years.
Collapse
Affiliation(s)
- Line S Reitlo
- Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Jelena M Mihailovic
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Dorthe Stensvold
- Department of Circulation and Medical Imaging, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Ulrik Wisløff
- Department of Circulation and Medical Imaging, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
- School of Human Movement and Nutrition Science, University of Queensland, Brisbane, Australia
| | - Fahmeed Hyder
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
| | - Asta Kristine Håberg
- Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway.
- Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.
| |
Collapse
|
3
|
Pfyffer D, Zimmermann S, Şimşek K, Kreis R, Freund P, Seif M. Magnetic resonance spectroscopy investigation in the right human hippocampus following spinal cord injury. Front Neurol 2023; 14:1120227. [PMID: 37251221 PMCID: PMC10213741 DOI: 10.3389/fneur.2023.1120227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 04/20/2023] [Indexed: 05/31/2023] Open
Abstract
Objective Preclinical studies have shown that cognitive impairments following spinal cord injury (SCI), such as impaired spatial memory, are linked to inflammation, neurodegeneration, and reduced neurogenesis in the right hippocampus. This cross-sectional study aims to characterize metabolic and macrostructural changes in the right hippocampus and their association to cognitive function in traumatic SCI patients. Methods Within this cross-sectional study, cognitive function was assessed in 28 chronic traumatic SCI patients and 18 age-, sex-, and education-matched healthy controls by a visuospatial and verbal memory test. A magnetic resonance spectroscopy (MRS) and structural MRI protocol was performed in the right hippocampus of both groups to quantify metabolic concentrations and hippocampal volume, respectively. Group comparisons investigated changes between SCI patients and healthy controls and correlation analyses investigated their relationship to memory performance. Results Memory performance was similar in SCI patients and healthy controls. The quality of the recorded MR spectra was excellent in comparison to the best-practice reports for the hippocampus. Metabolite concentrations and volume of the hippocampus measured based on MRS and MRI were not different between two groups. Memory performance in SCI patients and healthy controls was not correlated with metabolic or structural measures. Conclusion This study suggests that the hippocampus may not be pathologically affected at a functional, metabolic, and macrostructural level in chronic SCI. This points toward the absence of significant and clinically relevant trauma-induced neurodegeneration in the hippocampus.
Collapse
Affiliation(s)
- Dario Pfyffer
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
- Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Palo Alto, CA, United States
| | - Sandra Zimmermann
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
| | - Kadir Şimşek
- Magnetic Resonance Methodology, Institute of Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Roland Kreis
- Magnetic Resonance Methodology, Institute of Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Patrick Freund
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Maryam Seif
- Spinal Cord Injury Center, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| |
Collapse
|
4
|
Hui SC, Gong T, Zöllner HJ, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.18.524597. [PMID: 36711794 PMCID: PMC9882274 DOI: 10.1101/2023.01.18.524597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Purpose To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. Methods MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz.Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. Results SNR and linewidth were significantly higher (p<0.05) for sLASER than PRESS. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. Metabolite measures were significantly correlated (p<0.05) for most metabolites between the two methods except GABA, Gln and Lac in CSO and GSH, Lac and NAAG in PCC. Metabolite-age relationships were consistently identified using both PRESS and sLASER. Similar CVs were observed for most metabolites. Conclusion The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in 'good' brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
5
|
Ziegs T, Wright AM, Henning A. Test-retest reproducibility of human brain multi-slice 1 H FID-MRSI data at 9.4T after optimization of lipid regularization, macromolecular model, and spline baseline stiffness. Magn Reson Med 2022; 89:11-28. [PMID: 36128885 DOI: 10.1002/mrm.29423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 07/28/2022] [Accepted: 08/02/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE This study analyzes the effects of retrospective lipid suppression, a simulated macromolecular prior knowledge and different spline baseline stiffness values on 9.4T multi-slice proton FID-MRSI data spanning the whole cerebrum of human brain and the reproducibility of respective metabolite ratio to total creatine (/tCr) maps for 10 brain metabolites. METHODS Measurements were performed twice on 5 volunteers using a short TR and TE FID MRSI 2D sequence at 9.4T. The effects of retrospective lipid L2-regularization, macromolecular spectrum and different LCModel baseline flexibilities on SNR, FWHM, fitting residual, Cramér-Rao lower bound, and metabolite ratio maps were investigated. Intra-subject, inter-session coefficient of variation and the test-retest reproducibility of the mean metabolite ratios (/tCr) of each slice was calculated. RESULTS Transversal, sagittal, and coronal slices of many metabolite ratio maps correspond to the anatomically expected concentration relations in gray and white matter for the majority of the cerebrum when using a flexible baseline in LCModel fit. Results from the second measurements of the same subjects show that slice positioning and data quality correlate significantly to the first measurement. L2-regularization provided effective suppression of lipid-artifacts, but should be avoided if no artifacts are detected. CONCLUSION Reproducible concentration ratio maps (/tCr) for 4 metabolites (total choline, N-acetylaspartate, glutamate, and myoinositol) spanning the majority of the cerebrum and 6 metabolites (N-acetylaspartylglutamate, γ-aminobutyric acid, glutathione, taurine, glutamine, and aspartate) covering 32 mm in the upper part of the brain were acquired at 9.4T using multi-slice FID MRSI with retrospective lipid suppression, a macromolecular spectrum and a flexible LCModel baseline.
Collapse
Affiliation(s)
- Theresia Ziegs
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, Tübingen, Germany
| | - Andrew Martin Wright
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, Tübingen, Germany
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
6
|
Heckova E, Považan M, Strasser B, Motyka S, Hangel G, Hingerl L, Moser P, Lipka A, Gruber S, Trattnig S, Bogner W. Effects of different macromolecular models on reproducibility of FID-MRSI at 7T. Magn Reson Med 2020; 83:12-21. [PMID: 31393037 PMCID: PMC6851974 DOI: 10.1002/mrm.27922] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 06/12/2019] [Accepted: 07/08/2019] [Indexed: 12/25/2022]
Abstract
PURPOSE A properly characterized macromolecular (MM) contribution is essential for accurate metabolite quantification in FID-MRSI. MM information can be included into the fitting model as a single component or parameterized and included over several individual MM resonances, which adds flexibility when pathologic changes are present but is prone to potential overfitting. This study investigates the effects of different MM models on MRSI reproducibility. METHODS Clinically feasible, high-resolution FID-MRSI data were collected in ~5 min at 7 Tesla from 10 healthy volunteers and quantified via LCModel (version 6.3) with 3 basis sets, each with a different approach for how the MM signal was handled: averaged measured whole spectrum (full MM), 9 parameterized components (param MM) with soft constraints to avoid overparameterization, or without any MM information included in the fitting prior knowledge. The test-retest reproducibility of MRSI scans was assessed voxel-wise using metabolite coefficients of variation and intraclass correlation coefficients and compared between the basis sets. Correlations of concentration estimates were investigated for the param MM fitting model. RESULTS The full MM model provided the most reproducible quantification of total NAA, total Cho, myo-inositol, and glutamate + glutamine ratios to total Cr (coefficients of variations ≤ 8%, intraclass correlation coefficients ≥ 0.76). Using the param MM model resulted in slightly lower reproducibility (up to +3% higher coefficients of variations, up to -0.1 decreased intraclass correlation coefficients). The quantification of the parameterized macromolecules did not affect quantification of the overlapping metabolites. CONCLUSION Clinically feasible FID-MRSI with an experimentally acquired MM spectrum included in prior knowledge provides highly reproducible quantification for the most common neurometabolites in healthy volunteers. Parameterization of the MM spectrum may be preferred as a compromise between quantification accuracy and reproducibility when the MM content is expected to be pathologically altered.
Collapse
Affiliation(s)
- Eva Heckova
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Michal Považan
- Russell H. Morgan Department of Radiology and Radiological Science, The John Hopkins University School of Medicine, Baltimore, Maryland
| | - Bernhard Strasser
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Stanislav Motyka
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Gilbert Hangel
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Lukas Hingerl
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Philipp Moser
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Alexandra Lipka
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Stephan Gruber
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Wolfgang Bogner
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.,Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| |
Collapse
|
7
|
Graf C, MacMillan EL, Fu E, Harris T, Traboulsee A, Vavasour IM, MacKay AL, Mädler B, Li DKB, Laule C. Intra- and inter-site reproducibility of human brain single-voxel proton MRS at 3 T. NMR IN BIOMEDICINE 2019; 32:e4083. [PMID: 30889311 DOI: 10.1002/nbm.4083] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 01/24/2019] [Accepted: 01/28/2019] [Indexed: 06/09/2023]
Abstract
INTRODUCTION Clinical trials that involve participants from multiple sites necessitate standardized and reliable quantitative MRI outcomes to detect significant group differences over time. Metabolite concentrations measured by proton MRS (1 H-MRS) provide valuable information about in vivo metabolism of the central nervous system, but can vary based on the acquisition and quantitation methods used by different MR sites. Therefore, we investigated the intra- and inter-site reproducibility of metabolite concentrations measured by 1 H-MRS on MRI scanners from a single manufacturer across six sites. METHODS Five healthy controls were scanned twice within 24 h at six participating 3 T MR sites with large single-voxel PRESS (TE/TR/NSA = 36 ms/4000 ms/56) and anatomical images for voxel positioning and correction of partial volume relaxation. Absolute metabolite concentrations were calculated relative to the T1 and T2 relaxation corrected signal from water. Intra- and inter-site reproducibility was assessed using Bland-Altman plots and intra- and inter-site coefficient of variation (CoV) as well as intra- and inter-site intra-class correlation coefficient. RESULTS The median intra-site CoVs for the five major metabolite concentrations ([NAA], [tCr], [Glu], [tCho] and [Ins]) were between 2.5 and 5.3%. Inter-site CoVs were also low, with the median CoVs for all metabolites between 3.7 and 6.4%. Metabolite concentrations were robust to small inconsistencies in voxel placement and site was not the driving factor in the variance of the measurement of any metabolite concentration. Between-subject differences accounted for the majority of the concentration variability for creatine, choline and myo-inositol (42-65% of the variance). CONCLUSION A large single-voxel 1 H-MRS acquisition from a single manufacturer's MRI scanner is highly reproducible and reliable for multi-site clinical trials.
Collapse
Affiliation(s)
- Carina Graf
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
- International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada
| | - Erin L MacMillan
- MR Clinical Science, Philips Canada, Markham, Ontario, Canada
- UBC MRI Research Centre, University of British Columbia, Vancouver, British Columbia, Canada
- ImageTech Lab, Simon Fraser University, Surrey, British Columbia, Canada
| | - Eric Fu
- Statistics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Trudy Harris
- UBC MRI Research Centre, University of British Columbia, Vancouver, British Columbia, Canada
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Anthony Traboulsee
- Medicine (Neurology), University of British Columbia, Vancouver, British Columbia, Canada
| | - Irene M Vavasour
- UBC MRI Research Centre, University of British Columbia, Vancouver, British Columbia, Canada
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | - Alex L MacKay
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
- UBC MRI Research Centre, University of British Columbia, Vancouver, British Columbia, Canada
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada
| | | | - David K B Li
- UBC MRI Research Centre, University of British Columbia, Vancouver, British Columbia, Canada
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada
- Medicine (Neurology), University of British Columbia, Vancouver, British Columbia, Canada
| | - Cornelia Laule
- Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada
- International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada
- Radiology, University of British Columbia, Vancouver, British Columbia, Canada
- Pathology & Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
8
|
Diurnal stability and long-term repeatability of neurometabolites using single voxel 1H magnetic resonance spectroscopy. Eur J Radiol 2018; 108:107-113. [DOI: 10.1016/j.ejrad.2018.09.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Accepted: 09/15/2018] [Indexed: 11/16/2022]
|
9
|
Zhang Y, Taub E, Salibi N, Uswatte G, Maudsley AA, Sheriff S, Womble B, Mark VW, Knight DC. Comparison of reproducibility of single voxel spectroscopy and whole-brain magnetic resonance spectroscopy imaging at 3T. NMR IN BIOMEDICINE 2018; 31:e3898. [PMID: 29436038 PMCID: PMC6291009 DOI: 10.1002/nbm.3898] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 12/11/2017] [Accepted: 12/26/2017] [Indexed: 05/09/2023]
Abstract
To date, single voxel spectroscopy (SVS) is the most commonly used MRS technique. SVS is relatively easy to use and provides automated and immediate access to the resulting spectra. However, it is also limited in spatial coverage. A new and very promising MRS technique allows for whole-brain MR spectroscopic imaging (WB-MRSI) with much improved spatial resolution. Establishing the reproducibility of data obtained using SVS and WB-MRSI is an important first step for using these techniques to evaluate longitudinal changes in metabolite concentration. The purpose of this study was to assess and directly compare the reproducibility of metabolite quantification at 3T using SVS and WB-MRSI in 'hand-knob' areas of motor cortices and hippocampi in healthy volunteers. Ten healthy adults were scanned using both SVS and WB-MRSI on three occasions one week apart. N-acetyl aspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mI) were quantified using SVS and WB-MRSI with reference to both Cr and H2 O. The reproducibility of each technique was evaluated using the coefficient of variation (CV), and the correspondence between the two techniques was assessed using Pearson correlation analysis. The measured mean (range) intra-subject CVs for SVS were 5.90 (2.65-10.66)% for metabolites (i.e. NAA, Cho, mI) relative to Cr, and 8.46 (4.21-21.07)% for metabolites (NAA, Cr, Cho, mI) relative to H2 O. The mean (range) CVs for WB-MRSI were 7.56 (2.78-11.41)% for metabolites relative to Cr, and 7.79 (4.57-14.11)% for metabolites relative to H2 O. Significant positive correlations were observed between metabolites quantified using SVS and WB-MRSI techniques when the Cr but not H2 O reference was used. The results demonstrate that reproducibilities of SVS and WB-MRSI are similar for quantifying the four major metabolites (NAA, Cr, Cho, mI); both SVS and WB-MRSI exhibited good reproducibility. Our findings add reference information for choosing the appropriate 1 H-MRS technique in future studies.
Collapse
Affiliation(s)
- Yue Zhang
- Department of Psychology, University of Alabama at Birmingham, AL, USA
| | - Edward Taub
- Department of Psychology, University of Alabama at Birmingham, AL, USA
| | | | - Gitendra Uswatte
- Department of Psychology, University of Alabama at Birmingham, AL, USA
- Department of Physical Therapy, University of Alabama at Birmingham, AL, USA
| | | | | | - Brent Womble
- Department of Psychology, University of Alabama at Birmingham, AL, USA
| | - Victor W Mark
- Department of Psychology, University of Alabama at Birmingham, AL, USA
- Department of Physical Medicine and Rehabilitation, University of Alabama at Birmingham, AL, USA
- Department of Neurology, University of Alabama at Birmingham, AL, USA
| | - David C Knight
- Department of Psychology, University of Alabama at Birmingham, AL, USA
| |
Collapse
|
10
|
Terpstra M, Cheong I, Lyu T, Deelchand DK, Emir UE, Bednařík P, Eberly LE, Öz G. Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T. Magn Reson Med 2016; 76:1083-91. [PMID: 26502373 PMCID: PMC4846596 DOI: 10.1002/mrm.26022] [Citation(s) in RCA: 117] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 09/23/2015] [Accepted: 09/28/2015] [Indexed: 02/03/2023]
Abstract
PURPOSE To determine the test-retest reproducibility of neurochemical concentrations obtained with a highly optimized, short-echo, single-voxel proton MR spectroscopy (MRS) pulse sequence at 3T and 7T using state-of-the-art hardware. METHODS A semi-LASER sequence (echo time = 26-28 ms) was used to acquire spectra from the posterior cingulate and cerebellum at 3T and 7T from six healthy volunteers who were scanned four times weekly on both scanners. Spectra were quantified with LCModel. RESULTS More neurochemicals were quantified with mean Cramér-Rao lower bounds (CRLBs) ≤20% at 7T than at 3T despite comparable frequency-domain signal-to-noise ratio. Whereas CRLBs were lower at 7T (P < 0.05), between-session coefficients of variance (CVs) were comparable at the two fields with 64 transients. Five metabolites were quantified with between-session CVs ≤5% at both fields. Analysis of subspectra showed that a minimum achievable CV was reached with a lower number of transients at 7T for multiple metabolites and that between-session CVs were lower at 7T than at 3T with fewer than 64 transients. CONCLUSION State-of-the-art MRS methodology allows excellent reproducibility for many metabolites with 5-min data averaging on clinical 3T hardware. Sensitivity and resolution advantages at 7T are important for weakly represented metabolites, short acquisitions, and small volumes of interest. Magn Reson Med 76:1083-1091, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Melissa Terpstra
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Ian Cheong
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Tianmeng Lyu
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, Minnesota, USA
| | - Dinesh K Deelchand
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Uzay E Emir
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Petr Bednařík
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
- Division of Endocrinology and Diabetes, Department of Medicine, University of Minnesota, Minneapolis, Minnesota, USA
- Multimodal and Functional Neuroimaging Research Group, Central European Institute of Technology, Masaryk University, Brno, Czech Republic
| | - Lynn E Eberly
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, Minnesota, USA
| | - Gülin Öz
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.
| |
Collapse
|
11
|
Hippocampal harms, protection and recovery following regular cannabis use. Transl Psychiatry 2016; 6:e710. [PMID: 26756903 PMCID: PMC5068875 DOI: 10.1038/tp.2015.201] [Citation(s) in RCA: 95] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2015] [Accepted: 11/05/2015] [Indexed: 11/09/2022] Open
Abstract
Shifting policies towards legalisation of cannabis for therapeutic and recreational use raise significant ethical issues for health-care providers seeking evidence-based recommendations. We investigated whether heavy cannabis use is associated with persistent harms to the hippocampus, if exposure to cannabidiol offers protection, and whether recovery occurs with abstinence. To do this, we assessed 111 participants: 74 long-term regular cannabis users (with an average of 15.4 years of use) and 37 non-user healthy controls. Cannabis users included subgroups of participants who were either exposed to Δ9-tetrahydrocannabinol (THC) but not to cannabidiol (CBD) or exposed to both, and former users with sustained abstinence. Participants underwent magnetic resonance imaging from which three measures of hippocampal integrity were assessed: (i) volume; (ii) fractional anisotropy; and (iii) N-acetylaspartate (NAA). Three curve-fitting models across the entire sample were tested for each measure to examine whether cannabis-related hippocampal harms are persistent, can be minimised (protected) by exposure to CBD or recovered through long-term abstinence. These analyses supported a protection and recovery model for hippocampal volume (P=0.003) and NAA (P=0.001). Further pairwise analyses showed that cannabis users had smaller hippocampal volumes relative to controls. Users not exposed to CBD had 11% reduced volumes and 15% lower NAA concentrations. Users exposed to CBD and former users did not differ from controls on any measure. Ongoing cannabis use is associated with harms to brain health, underpinned by chronic exposure to THC. However, such harms are minimised by CBD, and can be recovered with extended periods of abstinence.
Collapse
|
12
|
Allaïli N, Valabrègue R, Auerbach EJ, Guillemot V, Yahia-Cherif L, Bardinet E, Jabourian M, Fossati P, Lehéricy S, Marjańska M. Single-voxel (1)H spectroscopy in the human hippocampus at 3 T using the LASER sequence: characterization of neurochemical profile and reproducibility. NMR IN BIOMEDICINE 2015; 28:1209-17. [PMID: 26282328 PMCID: PMC4573920 DOI: 10.1002/nbm.3364] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 06/17/2015] [Accepted: 06/18/2015] [Indexed: 05/22/2023]
Abstract
The hippocampus is crucial for long-term episodic memory and learning. It undergoes structural change in aging and is sensitive to neurodegenerative and psychiatric diseases. MRS studies have seldom been performed in the hippocampus due to technical challenges. The reproducibility of MRS in the hippocampus has not been evaluated at 3 T. The purpose of the present study was to quantify the concentration of metabolites in a small voxel placed in the hippocampus and evaluate the reproducibility of the quantification. Spectra were measured in a 2.4 mL voxel placed in the left hippocampus covering the body and most of the tail of the structure in 10 healthy subjects across three different sessions and quantified using LCModel. High-quality spectra were obtained, which allowed a reliable quantification of 10 metabolites including glutamate and glutamine. Reproducibility of MRS was evaluated with coefficient of variation, standard errors of measurement, and intraclass correlation coefficients. All of these measures showed improvement with increased number of averages. Changes of less than 5% in concentration of N-acetylaspartate, choline-containing compounds, and total creatine and of less than 10% in concentration of myo-inositol and the sum of glutamate and glutamine can be confidently detected between two measurements in a group of 20 subjects. A reliable and reproducible neurochemical profile of the human hippocampus was obtained using MRS at 3 T in a small hippocampal volume.
Collapse
Affiliation(s)
- Najib Allaïli
- Institut du cerveau et de la Moelle épinière – ICM, Centre de NeuroImagerie de Recherche – CENIR, Paris, France
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
- Université Paris Diderot, Sorbonne Paris Cité, Paris, F-75013, France
- APHP – Département de Psychiatrie et de Médecine Addictologique, Groupe Hospitalier Saint-Louis – Lariboisière – Fernand-Widal, Paris, France
| | - Romain Valabrègue
- Institut du cerveau et de la Moelle épinière – ICM, Centre de NeuroImagerie de Recherche – CENIR, Paris, France
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
| | - Edward J. Auerbach
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, USA
| | - Vincent Guillemot
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
- ICM, Plate-forme de Bio-informatique/Biostatistique, F-75013, Paris, France
| | - Lydia Yahia-Cherif
- Institut du cerveau et de la Moelle épinière – ICM, Centre de NeuroImagerie de Recherche – CENIR, Paris, France
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
| | - Eric Bardinet
- Institut du cerveau et de la Moelle épinière – ICM, Centre de NeuroImagerie de Recherche – CENIR, Paris, France
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
| | | | - Philippe Fossati
- Department of Psychiatry, Groupe Hospitalier Pitié-Salpêtrière, Paris, France
| | - Stéphane Lehéricy
- Institut du cerveau et de la Moelle épinière – ICM, Centre de NeuroImagerie de Recherche – CENIR, Paris, France
- Inserm U 1127, Paris, France
- CNRS UMR 7225, Paris, France
- Sorbonne Universités, UPMC Univ Paris 06 UMR S 1127, Paris, France
- Department of Neuroradiology, Groupe Hospitalier Pitié-Salpêtrière, Paris, France
| | - Małgorzata Marjańska
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, USA
| |
Collapse
|
13
|
Bednařík P, Moheet A, Deelchand DK, Emir UE, Eberly LE, Bareš M, Seaquist ER, Öz G. Feasibility and reproducibility of neurochemical profile quantification in the human hippocampus at 3 T. NMR IN BIOMEDICINE 2015; 28:685-93. [PMID: 25904240 PMCID: PMC4454404 DOI: 10.1002/nbm.3309] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 03/10/2015] [Accepted: 03/23/2015] [Indexed: 05/21/2023]
Abstract
Hippocampal dysfunction is known to be associated with several neurological and neuropsychiatric disorders such as Alzheimer's disease, epilepsy, schizophrenia and depression; therefore, there has been significant clinical interest in studying hippocampal neurochemistry. However, the hippocampus is a challenging region to study using (1) H MRS, hence the use of MRS for clinical research in this region has been limited. Our goal was therefore to investigate the feasibility of obtaining high-quality hippocampal spectra that allow reliable quantification of a neurochemical profile and to establish inter-session reproducibility of hippocampal MRS, including reproducibility of voxel placement, spectral quality and neurochemical concentrations. Ten healthy volunteers were scanned in two consecutive sessions using a standard clinical 3 T MR scanner. Neurochemical profiles were obtained with a short-echo (T(E) = 28 ms) semi-LASER localization sequence from a relatively small (~4 mL) voxel that covered about 62% of the hippocampal volume as calculated from segmentation of T1 -weighted images. Voxel composition was highly reproducible between sessions, with test-retest coefficients of variation (CVs) of 3.5% and 7.5% for gray and white matter volume fraction, respectively. Excellent signal-to-noise ratio (~54 based on the N-acetylaspartate (NAA) methyl peak in non-apodized spectra) and linewidths (~9 Hz for water) were achieved reproducibly in all subjects. The spectral quality allowed quantification of NAA, total choline, total creatine, myo-inositol and glutamate with high scan-rescan reproducibility (CV ≤ 6%) and quantification precision (Cramér-Rao lower bound, CRLB < 9%). Four other metabolites, including glutathione and glucose, were quantified with scan-rescan CV below 20%. Therefore, the highly optimized, short-echo semi-LASER sequence together with FASTMAP shimming substantially improved the reproducibility and number of quantifiable metabolites relative to prior reports. In addition, the between-session variation in metabolite concentrations, as well as CRLB, was lower than the between-subject variation of the concentrations for most metabolites, indicating that the method has the sensitivity to detect inter-individual differences in the healthy brain.
Collapse
Affiliation(s)
- Petr Bednařík
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, United States
- Division of Endocrinology and Diabetes, Department of Medicine, University of Minnesota, Minneapolis, MN, United States
- Multimodal and Functional Neuroimaging Research Group, Central European Institute of Technology, CEITEC MU, Brno, Czech Republic
| | - Amir Moheet
- Division of Endocrinology and Diabetes, Department of Medicine, University of Minnesota, Minneapolis, MN, United States
| | - Dinesh K. Deelchand
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, United States
| | - Uzay E. Emir
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, United States
| | - Lynn E. Eberly
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, MN, United States
| | - Martin Bareš
- Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, CEITEC MU, Brno, Czech Republic
- First Department of Neurology, Masaryk University and St. Anne's Teaching Hospital, Brno, Czech Republic
| | - Elizabeth R. Seaquist
- Division of Endocrinology and Diabetes, Department of Medicine, University of Minnesota, Minneapolis, MN, United States
| | - Gülin Öz
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|
14
|
van de Bank B, Emir U, Boer V, van Asten J, Maas M, Wijnen JP, Kan H, Oz G, Klomp D, Scheenen T. Multi-center reproducibility of neurochemical profiles in the human brain at 7 T. NMR IN BIOMEDICINE 2015; 28:306-16. [PMID: 25581510 PMCID: PMC4339538 DOI: 10.1002/nbm.3252] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 11/26/2014] [Accepted: 11/27/2014] [Indexed: 05/06/2023]
Abstract
The purpose of this work was to harmonize data acquisition and post-processing of single voxel proton MRS ((1) H-MRS) at 7 T, and to determine metabolite concentrations and the accuracy and reproducibility of metabolite levels in the adult human brain. This study was performed in compliance with local institutional human ethics committees. The same seven subjects were each examined twice using four different 7 T MR systems from two different vendors using an identical semi-localization by adiabatic selective refocusing spectroscopy sequence. Neurochemical profiles were obtained from the posterior cingulate cortex (gray matter, GM) and the corona radiata (white matter, WM). Spectra were analyzed with LCModel, and sources of variation in concentrations ('subject', 'institute' and 'random') were identified with a variance component analysis. Concentrations of 10-11 metabolites, which were corrected for T1 , T2 , magnetization transfer effects and partial volume effects, were obtained with mean Cramér-Rao lower bounds below 20%. Data variances and mean concentrations in GM and WM were comparable for all institutions. The primary source of variance for glutamate, myo-inositol, scyllo-inositol, total creatine and total choline was between subjects. Variance sources for all other metabolites were associated with within-subject and system noise, except for total N-acetylaspartate, glutamine and glutathione, which were related to differences in signal-to-noise ratio and in shimming performance between vendors. After multi-center harmonization of acquisition and post-processing protocols, metabolite concentrations and the sizes and sources of their variations were established for neurochemical profiles in the healthy brain at 7 T, which can be used as guidance in future studies quantifying metabolite and neurotransmitter concentrations with (1) H-MRS at ultra-high magnetic field.
Collapse
Affiliation(s)
- B.L. van de Bank
- Department of Radiology, Radboud university medical center, Nijmegen, the Netherlands
| | - U.E. Emir
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, United States of America
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, UK
| | - V.O. Boer
- Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - J.J.A. van Asten
- Department of Radiology, Radboud university medical center, Nijmegen, the Netherlands
| | - M.C. Maas
- Department of Radiology, Radboud university medical center, Nijmegen, the Netherlands
| | - J. P. Wijnen
- Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - H.E. Kan
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - G. Oz
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, United States of America
| | - D.W.J. Klomp
- Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands
| | - T.W.J. Scheenen
- Department of Radiology, Radboud university medical center, Nijmegen, the Netherlands
- Erwin L. Hahn Institute, University Hospital Duisburg-Essen, Essen, Germany
| |
Collapse
|
15
|
Physiological effects of cigarette smoking in the limbic system revealed by 3 tesla magnetic resonance spectroscopy. J Neural Transm (Vienna) 2014; 121:1211-9. [PMID: 24643301 DOI: 10.1007/s00702-014-1190-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2013] [Accepted: 03/02/2014] [Indexed: 01/07/2023]
Abstract
Several studies and recent models of effects of nicotine, the main addictive and psychoactive component in tobacco, point to action of the drug on the limbic system during maintenance of addiction, either direct or indirect via projections from the ventral tegmental area. The objective of this study was to demonstrate physiological effects of cigarette smoking on the hippocampus and the grey matter of the dorsal anterior cingulate cortex in the human brain with regard to addiction and withdrawal. This aim was achieved by group comparisons of results of magnetic resonance spectroscopy between non-smokers, smokers and smokers during withdrawal. 12 smokers and 12 non-smokers were measured with single voxel proton magnetic resonance spectroscopy for total N-acetyl aspartate, glutamate and glutamine, choline-containing compounds, myo-inositol and total creatine in the right and the left hippocampus and in the right and the left dorsal anterior cingulate cortex. Smokers were examined twice, first during regular cigarette smoking and second on the third day of nicotine withdrawal. The ratios to total creatine were used for better reliability. In our study, Glx/tCr was significantly increased and tCho/tCr was significantly decreased in the left cingulate cortex in smokers compared to non-smokers (p = 0.01, both). Six out of seven smokers showed normalization of the Glx/tCr in the left cingulate cortex during withdrawal. Although these results are preliminary due to the small sample size, our results confirm the assumption that cigarette smoking interferes directly or indirectly with the glutamate circuit in the dorsal anterior cingulate cortex.
Collapse
|
16
|
Öz G, Alger JR, Barker PB, Bartha R, Bizzi A, Boesch C, Bolan PJ, Brindle KM, Cudalbu C, Dinçer A, Dydak U, Emir UE, Frahm J, González RG, Gruber S, Gruetter R, Gupta RK, Heerschap A, Henning A, Hetherington HP, Howe FA, Hüppi PS, Hurd RE, Kantarci K, Klomp DWJ, Kreis R, Kruiskamp MJ, Leach MO, Lin AP, Luijten PR, Marjańska M, Maudsley AA, Meyerhoff DJ, Mountford CE, Nelson SJ, Pamir MN, Pan JW, Peet AC, Poptani H, Posse S, Pouwels PJW, Ratai EM, Ross BD, Scheenen TWJ, Schuster C, Smith ICP, Soher BJ, Tkáč I, Vigneron DB, Kauppinen RA. Clinical proton MR spectroscopy in central nervous system disorders. Radiology 2014; 270:658-79. [PMID: 24568703 PMCID: PMC4263653 DOI: 10.1148/radiol.13130531] [Citation(s) in RCA: 411] [Impact Index Per Article: 41.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
A large body of published work shows that proton (hydrogen 1 [(1)H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of (1)H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of (1)H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which (1)H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units.
Collapse
Affiliation(s)
- Gülin Öz
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Jeffry R. Alger
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Peter B. Barker
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Robert Bartha
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Alberto Bizzi
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Chris Boesch
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Patrick J. Bolan
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Kevin M. Brindle
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Cristina Cudalbu
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Alp Dinçer
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Ulrike Dydak
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Uzay E. Emir
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Jens Frahm
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Ramón Gilberto González
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Stephan Gruber
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Rolf Gruetter
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Rakesh K. Gupta
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Arend Heerschap
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Anke Henning
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Hoby P. Hetherington
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Franklyn A. Howe
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Petra S. Hüppi
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Ralph E. Hurd
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Kejal Kantarci
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Dennis W. J. Klomp
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Roland Kreis
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Marijn J. Kruiskamp
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Martin O. Leach
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Alexander P. Lin
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Peter R. Luijten
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Małgorzata Marjańska
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Andrew A. Maudsley
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Dieter J. Meyerhoff
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Carolyn E. Mountford
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Sarah J. Nelson
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - M. Necmettin Pamir
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Jullie W. Pan
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Andrew C. Peet
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Harish Poptani
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Stefan Posse
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Petra J. W. Pouwels
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Eva-Maria Ratai
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Brian D. Ross
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Tom W. J. Scheenen
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Christian Schuster
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Ian C. P. Smith
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Brian J. Soher
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Ivan Tkáč
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | - Daniel B. Vigneron
- From the Center for Magnetic Resonance Research, University of Minnesota,
2021 6th St SE, Minneapolis, MN 55455 (G.O.)
| | | |
Collapse
|
17
|
Differential impact of hyponatremia and hepatic encephalopathy on health-related quality of life and brain metabolite abnormalities in cirrhosis. J Hepatol 2013; 59:467-73. [PMID: 23665182 PMCID: PMC3748234 DOI: 10.1016/j.jhep.2013.04.023] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Revised: 04/16/2013] [Accepted: 04/20/2013] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS Hyponatremia (HN) and hepatic encephalopathy (HE) together can impair health-related quality of life (HRQOL) and cognition in cirrhosis. We aimed at studying the effect of hyponatremia on cognition, HRQOL, and brain MR spectroscopy (MRS) independent of HE. METHODS Four cirrhotic groups (no HE/HN, HE alone, HN alone (sodium <130 mEq/L), HE+HN) underwent cognitive testing, HRQOL using Sickness Impact Profile (SIP: higher score is worse; has psychosocial and physical sub-scores) and brain MRS (myoinositol (mI) and glutamate+glutamine (Glx)), which were compared across groups. A subset underwent HRQOL testing before/after diuretic withdrawal. RESULTS 82 cirrhotics (30 no HE/HN, 25 HE, 17 HE+HN, and 10 HN, MELD 12, 63% hepatitis C) were included. Cirrhotics with HN alone and without HE/HN had better cognition compared to HE groups (median abnormal tests no-HE/HN: 3, HN: 3.5, HE: 6.5, HE+HN: 7, p=0.008). Despite better cognition, HN only patients had worse HRQOL in total and psychosocial SIP while both HN groups (with/without HE) had a significantly worse physical SIP (p<0.0001, all comparisons). Brain MRS showed the lowest Glx in HN and the highest in HE groups (p<0.02). mI levels were comparably decreased in the three affected (HE, HE+HN, and HN) groups compared to no HE/HN and were associated with poor HRQOL. Six HE+HN cirrhotics underwent diuretic withdrawal which improved serum sodium and total/psychosocial SIP scores. CONCLUSIONS Hyponatremic cirrhotics without HE have poor HRQOL despite better cognition than those with concomitant HE. Glx levels were lowest in HN without HE but mI was similar across affected groups. HRQOL improved after diuretic withdrawal. Hyponatremia has a complex, non-linear relationship with brain Glx and mI, cognition and HRQOL.
Collapse
|
18
|
Kubo H, Harada M, Sakama M, Matsuda T, Otsuka H. Preliminary observation of dynamic changes in alcohol concentration in the human brain with proton magnetic resonance spectroscopy on a 3T MR instrument. Magn Reson Med Sci 2013; 12:235-40. [PMID: 23857146 DOI: 10.2463/mrms.2012-0056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Our purposes were to establish suitable conditions for proton magnetic resonance spectroscopy (MRS) to measure dynamic changes in alcohol concentration in the human brain, to evaluate these changes, and to compare the findings with data from analysis of breath vapor and blood samples. MATERIALS AND METHODS We evaluated 4 healthy volunteers (mean age 26.5 years; 3 males, one female) with no neurological findings. All studies were performed with 3-tesla clinical equipment using an 8-channel head coil. We applied our modified single-voxel point-resolved spectroscopy (PRESS) sequence. Continuous measurements of MRS, breath vapor, and blood samples were conducted before and after the subjects drank alcohol with a light meal. The obtained spectra were quantified by LCModel Ver. 6.1, and the accuracy of the MRS measurements was estimated using the estimated standard deviation expressed in percentage (%SD) as a criterion. RESULTS Alcohol peaks after drinking were clearly detected at 1.2 ppm for all durations of measurement. Good correlations between breath vapor or blood sample and MRS were found by sub-minute MRS measurement. The continuous measurement showed time-dependent changes in alcohol in the brain and various patterns that differed among subjects. CONCLUSIONS The clinical 3T equipment enables direct evaluation of sub-minute changes in alcohol metabolism in the human brain.
Collapse
Affiliation(s)
- Hitoshi Kubo
- Department of Medical Imaging, Institute of Health Biosciences, The University of Tokushima Graduate School
| | | | | | | | | |
Collapse
|
19
|
In vivo intervertebral disc characterization using magnetic resonance spectroscopy and T1ρ imaging: association with discography and Oswestry Disability Index and Short Form-36 Health Survey. Spine (Phila Pa 1976) 2012; 37:214-21. [PMID: 21697767 PMCID: PMC3633556 DOI: 10.1097/brs.0b013e3182294a63] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN An in vivo study of intervertebral disc degeneration by using quantitative magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS). OBJECTIVE To quantify water and proteoglycan (PG) content in the intervertebral disc by using in vivo MRS and to evaluate the relationship between MRS-quantified water/PG content, T1ρ, Pfirrmann score, clinical self-assessment, and discography. SUMMARY OF BACKGROUND DATA Previous in vitro studies have investigated the relationship between MRS-quantified water/PG content and degenerative grade by using cadaveric intervertebral discs. T1ρ has been shown to relate to Pfirrmann grade and clinical self-assessment. However, the associations between MRS-quantified water/PG content, MRI-based T1ρ, self-assessment of health status, and clinical response to discography have not been studied in vivo. METHODS MRS and MRI were performed in 26 patients (70 discs) with symptomatic intervertebral degenerative disc (IVDD) and 23 controls (41 discs). Patients underwent evaluation of intervertebral discs with provocative discography. All subjects completed the Short Form-36 Health Survey and Oswestry Disability Index questionnaires. RESULTS The water/PG peak area ratio was significantly elevated in (a) patients (compared with controls) and in (b) discs with positive discography (compared with negative discography). Magnetic resonance (MR) T1ρ exhibited similar trends. A significant association was found between T1ρ and normalized PG content (R = 0.61, P < 0.05) but not between T1ρ and normalized water content (R = 0.24, P > 0.05). The water/PG peak area ratio, normalized water, normalized PG, and Pfirrmann grade were significantly associated with patient self-assessment of disability and physical composite score, while disc height was not. CONCLUSION This study demonstrated a relationship between in vivo MRS spectroscopy (water content and PG content), imaging parameters (T1ρ and Pfirrmann grade), discography results, and clinical self-assessment, suggesting that MRS-quantified water, PG, and MR T1ρ relaxation time may potentially serve as biomarkers of symptomatic IVDD.
Collapse
|
20
|
Quantitative proton magnetic resonance spectroscopy and spectroscopic imaging of the brain: a didactic review. Top Magn Reson Imaging 2011; 21:115-28. [PMID: 21613876 DOI: 10.1097/rmr.0b013e31821e568f] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
This article presents background information related to methodology for estimating brain metabolite concentration from magnetic resonance spectroscopy (MRS) and magnetic resonance spectroscopic imaging measurements of living human brain tissue. It reviews progress related to this methodology, with emphasis placed on progress reported during the past 10 years. It is written for a target audience composed of radiologists and magnetic resonance imaging technologists. It describes in general terms the relationship between MRS signal amplitude and concentration. It then presents an overview of the many practical problems associated with deriving concentration solely from absolute measured signal amplitudes and demonstrates how a various signal calibration approaches can be successfully used. The concept of integrated signal amplitude is presented with examples that are helpful for qualitative reading of MRS data as well as for understanding the methodology used for quantitative measurements. The problems associated with the accurate measurement of individual signal amplitudes in brain spectra having overlapping signals from other metabolites and overlapping nuisance signals from water and lipid are presented. Current approaches to obtaining accurate amplitude estimates with least-squares fitting software are summarized.
Collapse
|
21
|
Multi-voxel magnetic resonance spectroscopy at 3T in patients with idiopathic generalised epilepsy. Seizure 2010; 19:485-92. [PMID: 20688545 DOI: 10.1016/j.seizure.2010.07.005] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2010] [Revised: 05/23/2010] [Accepted: 07/09/2010] [Indexed: 11/23/2022] Open
|
22
|
Doelken MT, Hammen T, Bogner W, Mennecke A, Stadlbauer A, Boettcher U, Doerfler A, Stefan H. Alterations of intracerebral γ-aminobutyric acid (GABA) levels by titration with levetiracetam in patients with focal epilepsies. Epilepsia 2010; 51:1477-82. [DOI: 10.1111/j.1528-1167.2010.02544.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
23
|
Wijnen JP, van Asten JJA, Klomp DWJ, Sjobakk TE, Gribbestad IS, Scheenen TWJ, Heerschap A. Short echo time 1H MRSI of the human brain at 3T with adiabatic slice-selective refocusing pulses; reproducibility and variance in a dual center setting. J Magn Reson Imaging 2010; 31:61-70. [PMID: 20027568 DOI: 10.1002/jmri.21999] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To assess the reproducibility of (1)H-MR spectroscopic imaging (MRSI) of the human brain at 3T with volume selection by a double spin echo sequence for localization with adiabatic refocusing pulses (semi-LASER). MATERIALS AND METHODS Twenty volunteers in two different institutions were measured twice with the same pulse sequence at an echo time of 30 msec. Magnetic resonance (MR) spectra were analyzed with LCModel with a simulated basis set including an experimentally acquired macromolecular signal profile. For specific regions in the brain mean metabolite levels, within and between subject variance, and the coefficient of variation (CoV) were calculated (for taurine, glutamate, total N-acetylaspartate, total creatine, total choline, myo-inositol + glycine, and glutamate + glutamine). RESULTS Repeated measurements showed no significant differences with a paired t-test and a high reproducibility (CoV ranging from 3%-30% throughout the selected volume). Mean metabolite levels and CoV obtained in similar regions in the brain did not differ significantly between two contributing institutions. The major source of differences between different measurements was identified to be the between-subject variations in the volunteers. CONCLUSION We conclude that semi-LASER (1)H-MRSI at 3T is an adequate method to obtain quantitative and reproducible measures of metabolite levels over large parts of the brain, applicable across multiple centers.
Collapse
Affiliation(s)
- Jannie P Wijnen
- Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
24
|
Zuo J, Saadat E, Romero A, Loo K, Li X, Link TM, Kurhanewicz J, Majumdar S. Assessment of intervertebral disc degeneration with magnetic resonance single-voxel spectroscopy. Magn Reson Med 2010; 62:1140-6. [PMID: 19780173 DOI: 10.1002/mrm.22093] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This study examined the feasibility of using short-echo water-suppressed point-resolved spectroscopy (PRESS) on a clinical 3T magnetic resonance (MR) scanner for evaluating biochemical changes in degenerated bovine and cadaveric human intervertebral discs. In bovine discs (N = 17), degeneration was induced with papain injections. Degeneration of human cadaveric discs (N = 27) was assessed using the Pfirrmann grading on T(2)-weighted images. Chemicals in the carbohydrate region (Carb), the choline head group (Cho), the N-acetyl region (N-acetyl), and the lipid and lactate region (Lac+Lip) were quantified using (1)H PRESS, and were compared between specimens with different degrees of degeneration. The correlation between the spectroscopic findings and glycosaminoglycan (GAG) quantification using biochemical assays was determined. Significant differences were found between the ratios (N-acetyl/Cho, N-acetyl/Lac+Lip) acquired before and after papain injection in bovine discs. For human cadaveric discs, significant differences in the ratios (N-acetyl/Carb, N-acetyl/Lac+Lip) were found between discs having high and low Pfirrmann scores. Significant correlations were found between N-acetyl/Lac+Lip and GAG content in bovine discs (R = 0.77, P = 0.0007) and cadaveric discs (R = 0.83, P < 0.0001). Significant correlation between N-acetyl/Cho and GAG content was also found in cadaver discs (R = 0.64, P = 0.0039). This study demonstrates for the first time that short-echo PRESS on a clinical 3T MR scanner can be used to noninvasively and can reproducibly quantify metabolic changes associated with degeneration of intervertebral discs.
Collapse
Affiliation(s)
- Jin Zuo
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA.
| | | | | | | | | | | | | | | |
Collapse
|
25
|
Doelken MT, Mennecke A, Stadlbauer A, Kloska S, Struffert T, Engelhorn T, Thuerauf N, Doerfler A, Stefan H, Hammen T. Multi-voxel magnetic resonance spectroscopy of cerebral metabolites in healthy adults at 3 Tesla. Acad Radiol 2009; 16:1493-501. [PMID: 19781961 DOI: 10.1016/j.acra.2009.07.025] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2009] [Revised: 07/08/2009] [Accepted: 07/23/2009] [Indexed: 11/28/2022]
Abstract
RATIONALE AND OBJECTIVES The objective of this study was to determine how metabolite values (total N-acetyl aspartate [tNAA], glutamate plus glutamine [Glx], total choline [tCho], myoinositol [mI], and total creatine [tCr]) vary across brain regions in healthy subjects. This study was implemented to create an internal reference database for patients with psychiatric disorders and epilepsy. MATERIALS AND METHODS Using the multivoxel technique with a voxelwise phantom calibration on a 3-T magnetic resonance imaging scanner, metabolite levels of 29 healthy controls (13 men, 16 women; average age, 29 years) were obtained from the hippocampi, basal ganglia, insula cortex, cingulum, and precuneus. Additionally, gray and white matter metabolite values were obtained from the frontal and parietal lobes. RESULTS No significant effect of gender was noticed. The total magnitude of variation was greatest for Glx, followed by tNAA, mI, tCho, and tCr. Glx/tCr, Glx, and tCr were increased in gray matter, while tNAA/tCr, tCho/tCr, respectively tNAA and tCho, were elevated in white matter. These findings indicate (1) anterior-to-posterior increases of tNAA/tCr and Glx/tCr, respectively tNAA and Glx, along the midline in gray matter (cingulum); (2) increased tNAA/tCr, respectively tNAA, in white matter in the fiber tracts of the precentral region; (3) an accentuated anterior-to-posterior increase of tCr in the insula cortex; and (4) an anterior-to-posterior decrease of tCho/tCr and tCho in white matter. CONCLUSIONS There are significant metabolic differences within tissue types and within tissue types at different locations; therefore, the spectra and metabolite values presented should provide a useful internal reference for both clinical and research studies.
Collapse
Affiliation(s)
- Marc Thorsten Doelken
- Department of Neuroradiology, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Gimenez M, Soria-Pastor S, Junque C, Caldu X, Narberhaus A, Botet F, Bargallo N, Falcon C, Mercader JM. Proton magnetic resonance spectroscopy reveals medial temporal metabolic abnormalities in adolescents with history of preterm birth. Pediatr Res 2008; 64:572-7. [PMID: 18596571 DOI: 10.1203/pdr.0b013e3181841eab] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Prematurity is associated with volumetric reductions in specific brain areas such as the hippocampus and with metabolic changes that can be detected by spectroscopy. Short echo time (35 ms) Proton magnetic resonance spectroscopy (1H MRS) was performed to assess possible medial temporal lobe metabolic abnormalities in 21 adolescents with preterm birth (mean age: 14.8, SD: 1.3) compared with an age-matched control sample (mean age: 14.8, SD: 1.6). 1H MRS spectra were analyzed with linear combination model fitting, obtaining the absolute metabolite concentrations for Creatine (Cr), and myo-inositol (Ins). In addition, the following metabolite sums were measured: total Cho (glycerophospho-choline + phosphocholine), total N-acetyl-aspartate + N-acetyl-aspartylglutamate (NA), and total Glx (glutamate + glutamine). A stereological analysis was performed to calculate hippocampal volume. Absolute Cr, and total NA values were decreased in the preterm group (p = 0.016; p = 0.002, respectively). The preterm also showed a hippocampal reduction (p < 0.0001). Significant relationships were found between gestational age and different metabolites and the hippocampal volume. Moreover, hippocampal volume correlated with brain metabolites in the whole sample. Results demonstrate that prematurity affects medial temporal lobe metabolites, and that the alteration is related to structural changes, suggesting that the cerebral changes persist until adolescence.
Collapse
Affiliation(s)
- Monica Gimenez
- Department of Psychiatry and Clinical Psychobiology, University of Barcelona, Barcelona 08036, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Doelken M, Stefan H, Pauli E, Stadlbauer A, Struffert T, Engelhorn T, Richter G, Ganslandt O, Doerfler A, Hammen T. 1H-MRS profile in MRI positive- versus MRI negative patients with temporal lobe epilepsy. Seizure 2008; 17:490-7. [DOI: 10.1016/j.seizure.2008.01.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2007] [Revised: 01/08/2008] [Accepted: 01/23/2008] [Indexed: 01/09/2023] Open
|
28
|
Hammen T, Hildebrandt M, Stadlbauer A, Doelken M, Engelhorn T, Kerling F, Kasper B, Romstoeck J, Ganslandt O, Nimsky C, Blumcke I, Doerfler A, Stefan H. Non-invasive detection of hippocampal sclerosis: correlation between metabolite alterations detected by (1)H-MRS and neuropathology. NMR IN BIOMEDICINE 2008; 21:545-552. [PMID: 18035849 DOI: 10.1002/nbm.1222] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We assessed (1)H-MRS as a screening tool for detection of hippocampal sclerosis in patients with temporal lobe epilepsy (TLE). (1)H-MRS was carried out in the hippocampus of 23 patients with unilateral TLE. Metabolite alterations detected by (1)H-MRS correlated with degree of segmental neuronal cell loss and amount of astrogliosis. Positive correlation was found between total N-Acetylaspartate (tNAA) reduction and neuronal density in hippocampal CA1 (P < 0.001), CA3 (P = 0.015), and CA4 subfields (P = 0.031) and the dentate gyrus (P = 0.006). Neuronal cell loss in CA1 turned out to be the most predictive and only significant variable for tNAA reduction (P = 0.027). The association between myo-inositol (m-Ins) and astroglial glial fibrillary acidic protein (GFAP) expression revealed significantly increased m-Ins concentrations associated with diffuse astrogliosis (m-Ins = 6.4 +/- 1.1 institutional units) compared with gliosis restricted to isolated sectors of the hippocampus (i.e. hilus) (m-Ins = 5.2 +/- 1.2 institutional units) (P = 0.039). A negative correlation was found between m-Ins and neuronal loss in the CA4 subfield of the hippocampus (P = 0.028). Our results support (1)H-MRS as a suitable non-invasive method for preoperative identification of hippocampal sclerosis in patients with TLE. The extent of tNAA reduction correlates with hippocampal neuronal cell density. Furthermore, m-Ins is associated with the extent of hippocampal astrogliosis.
Collapse
Affiliation(s)
- Thilo Hammen
- Center Epilepsy Erlangen (ZEE), Department of Neurology, University of Erlangen-Nuremberg, Erlangen, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Craig MC, Daly EM, O'Gorman R, Rymer J, Lythgoe D, Ng G, Simmons A, Maki PM, Murphy DGM. Effects of acute ovarian hormone suppression on the human brain: an in vivo 1H MRS study. Psychoneuroendocrinology 2007; 32:1128-32. [PMID: 17658694 DOI: 10.1016/j.psyneuen.2007.06.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2007] [Revised: 06/01/2007] [Accepted: 06/02/2007] [Indexed: 11/16/2022]
Abstract
A previous proton magnetic resonance spectroscopy ((1)H MRS) study carried out by our group indicated that post-menopausal women who started taking oestrogen therapy (ET) at or around the menopause had a significantly lower choline (Cho) concentration in the hippocampus and parietal lobe than those who were ET naïve, suggesting that long-term ET positively modulates neuronal/glial membrane turnover in older females. The objective of the current study was to determine whether neuronal membrane turnover is modulated by sex hormones in younger women following a pharmacologic challenge that induced acute ovarian hormone suppression. We carried out an in vivo(1)H MRS study in a group of 10 premenopausal women pre- and post-8 weeks of acute ovarian suppression with a Gonadotrophin Releasing Hormone analogue (GnRHa) (two Zoladex 3.6 mg implants). We report that young women, post-ovarian suppression, had a significant increase in Cho concentration (and Cho/Cr ratio) in the dorsolateral prefrontal cortex (DLPFC). They also showed a trend to a significant increase in Cho concentration in the hippocampus. This supports our previous findings and adds to the evidence that neuronal/glial membrane metabolism is affected by sex hormones in women.
Collapse
Affiliation(s)
- Michael C Craig
- Department of Psychological Medicine, Institute of Psychiatry, Section of Brain Maturation, London, UK.
| | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Over the past two decades, proton magnetic resonance spectroscopy (proton MRS) of the brain has made the transition from research tool to a clinically useful modality. In this review, we first describe the localization methods currently used in MRS studies of the brain and discuss the technical and practical factors that determine the applicability of the methods to particular clinical studies. We also describe each of the resonances detected by localized solvent-suppressed proton MRS of the brain and discuss the metabolic and biochemical information that can be derived from an analysis of their concentrations. We discuss spectral quantitation and summarize the reproducibility of both single-voxel and multivoxel methods at 1.5 and 3-4 T. We have selected three clinical neurologic applications in which there has been a consensus as to the diagnostic value of MRS and summarize the information relevant to clinical applications. Finally, we speculate about some of the potential technical developments, either in progress or in the future, that may lead to improvements in the performance of proton MRS.
Collapse
Affiliation(s)
- Yael Rosen
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 02215 Boston, Massachusetts
| | - Robert E. Lenkinski
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, 02215 Boston, Massachusetts
| |
Collapse
|
31
|
Højrup S, Jensen FT, Hokland S, Simonsen C, Christensen T, Frøkiaer J, Pedersen M. Interobserver and within-subject variances of T2-relaxation time and 1H-metabolite ratios in the normal hippocampus. J Neuroradiol 2007; 34:198-204. [PMID: 17568675 DOI: 10.1016/j.neurad.2007.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE To investigate the magnetic resonance (MR) reproducibility of normal hippocampal volume (HV), temporal lobe volume (TLV), transversal relaxation time (T(2)) and (1)H-MR spectroscopy ((1)H-MRS) metabolite ratios. MATERIALS AND METHODS Two sets of HV, TLV, T(2) and MR spectroscopic metabolite signal ratios were determined in 27 healthy volunteers. HV and TLV were measured with a T(1)-weighted MR sequence; whereas T(2) measurements were performed with conventional spin-echo (CSE) and fast spin-echo (FSE) MR imaging sequences. The interobserver and within-subject variances of T(2) measurements were estimated. RESULTS Estimated right and left HV coefficients of variation (CV)=0.13. FSE T(2) measurements showed no significant differences in the interobserver (CV=0.02) and within-subject variances (CV=0.02). Measurements showed no differences in the interobserver (CV=0.02) and within-subject (CV=0.04) variances for the CSE T(2) of the right and left hippocampi. Metabolite ratios between N-acetyl aspartate (NAA) and creatine (Cr), choline (Cho) and creatine, and NAA and choline plus creatine (Cho + Cr) for the right hippocampus were 2.29+/-0.19, 1.52+/-0.14 and 0.91+/-0.05, respectively. Metabolite ratios for the left hippocampus were 2.18+/-0.10, 1.48+/-0.10 and 0.88+/-0.06, respectively. CONCLUSIONS HV, TLV, T(2) and (1)H MRS metabolite ratio measurements showed fair reproducibility with small CVs, and no differences in the interobserver and within-subject variances, including no differences between right and left TLV, and in the right and left T(2).
Collapse
Affiliation(s)
- S Højrup
- MR Research Center, Aarhus University Hospital, 8200 Aarhus, Denmark
| | | | | | | | | | | | | |
Collapse
|
32
|
Langer DL, Rakaric P, Kirilova A, Jaffray DA, Damyanovich AZ. Assessment of metabolite quantitation reproducibility in serial 3D-1H-MR spectroscopic imaging of human brain using stereotactic repositioning. Magn Reson Med 2007; 58:666-73. [PMID: 17899591 DOI: 10.1002/mrm.21351] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Intrasubject reproducibility of metabolite quantitation in three-dimensional proton magnetic resonance spectroscopic imaging (3D-MRSI) was investigated in 10 healthy volunteers over five separate sessions using two echo times (TEs): 144 and 30 ms. The use of a Gill-Thomas-Cosman (GTC) stereotactic head frame enabled precise subject repositioning and immobilization. Metabolite levels from each voxel in the volume of interest (VOI) were quantified using the Linear Combination of Model spectra (LCModel) analysis algorithm, and coefficients of variation (CVs) were calculated. Standard error estimates (%SD or Cramer-Rao lower bounds) generated by LCModel were used as a confidence filter. The 95% confidence interval (CI) was found for each metabolite, providing an indication of the normal fluctuation expected for 3D-MRSI. In vivo, median CVs at the %SD < or = 20 level were found to be (%CV for TE = 144 and 30 ms, respectively): N-acetyl-aspartate plus N-acetyl-aspartyl-glutamate (NAA): 10.2% and 13.5%; creatine plus phosphocreatine (Cr), 14.4% and 21.7%; and choline-containing compounds (Cho), 15.2% and 18.4%. Relaxing the statistical filtering criteria to %SD < or = 30 increased median CVs by less than 5% and permitted in vivo quantitation reproducibility to be evaluated for glutamine plus glutamate (Glx) and myoinositol (Ins) for TE = 30 ms, yielding CVs of 24.0% and 21.0%, respectively.
Collapse
Affiliation(s)
- Deanna L Langer
- Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario, Canada
| | | | | | | | | |
Collapse
|