Schüre JR, Casagranda S, Sedykh M, Liebig P, Papageorgakis C, Mancini L, Bisdas S, Nichelli L, Pinter N, Mechtler L, Jafari R, Boddaert N, Dangouloff-Ros V, Poujol J, Schmidt M, Doerfler A, Zaiss M. Fluid suppression in amide proton transfer-weighted (APTw) CEST imaging: New theoretical insights and clinical benefits. Magn Reson Med 2024; 91:1354-1367. [PMID: 38073061 DOI: 10.1002/mrm.29915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 10/17/2023] [Accepted: 10/18/2023] [Indexed: 02/03/2024]
Abstract
PURPOSE Amide proton transfer-weighted (APTw) MRI at 3T provides a unique contrast for brain tumor imaging. However, APTw imaging suffers from hyperintensities in liquid compartments such as cystic or necrotic structures and provides a distorted APTw signal intensity. Recently, it has been shown that heuristically motivated fluid suppression can remove such artifacts and significantly improve the readability of APTw imaging. THEORY AND METHODS In this work, we show that the fluid suppression can actually be understood by the known concept of spillover dilution, which itself can be derived from the Bloch-McConnell equations in comparison to the heuristic approach. Therefore, we derive a novel post-processing formula that efficiently removes fluid artifact, and explains previous approaches. We demonstrate the utility of this APTw assessment in silico, in vitro, and in vivo in brain tumor patients acquired at MR scanners from different vendors. RESULTS Our results show a reduction of the CEST signals from fluid environments while keeping the APTw-CEST signal intensity almost unchanged for semi-solid tissue structures such as the contralateral normal appearing white matter. This further allows us to use the same color bar settings as for conventional APTw imaging. CONCLUSION Fluid suppression has considerable value in improving the readability of APTw maps in the neuro-oncological field. In this work, we derive a novel post-processing formula from the underlying Bloch-McConnell equations that efficiently removes fluid artifact, and explains previous approaches which justify the derivation of this metric from a theoretical point of view, to reassure the scientific and medical field about its use.
Collapse
Affiliation(s)
- Jan-Rüdiger Schüre
- Institute of Neuroradiology, University Clinic Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Stefano Casagranda
- Department of R&D Advanced Applications, Olea Medical, La Ciotat, France
| | - Maria Sedykh
- Institute of Neuroradiology, University Clinic Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | | | - Laura Mancini
- Lysholm Department of Neuroradiology, University College of London Hospitals NHS Foundation Trus, London, UK
- Institute of Neurology UCL, London, UK
| | - Sotirios Bisdas
- Lysholm Department of Neuroradiology, University College of London Hospitals NHS Foundation Trus, London, UK
- Institute of Neurology UCL, London, UK
| | - Lucia Nichelli
- Department of Neuroradiology, Sorbonne Université, AP-HP, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Paris, France
| | - Nandor Pinter
- DENT Neurologic Institute, Buffalo, New York, USA
- Department of Radiology, Jacobs School of Medicine and Biomedical Sciences, State University of New York, Buffalo, New York, USA
| | | | - Ramin Jafari
- Philips Healthcare, Cambridge, Massachusetts, USA
| | - Nathalie Boddaert
- Necker-Enfants Malades Hospital, AP-HP, Pediatric Radiology Department, Université Paris, Paris, France
- Imagine Institute, INSERM U1163, Université Paris cité, Paris, France
| | - Volodia Dangouloff-Ros
- Necker-Enfants Malades Hospital, AP-HP, Pediatric Radiology Department, Université Paris, Paris, France
- Imagine Institute, INSERM U1163, Université Paris cité, Paris, France
| | | | - Manuel Schmidt
- Institute of Neuroradiology, University Clinic Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Arnd Doerfler
- Institute of Neuroradiology, University Clinic Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Moritz Zaiss
- Institute of Neuroradiology, University Clinic Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
2
|
Igarashi T, Kim H, Sun PZ. Detection of tissue pH with quantitative chemical exchange saturation transfer magnetic resonance imaging. NMR IN BIOMEDICINE 2023; 36:e4711. [PMID: 35141979 PMCID: PMC10249910 DOI: 10.1002/nbm.4711] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 02/03/2022] [Accepted: 02/05/2022] [Indexed: 05/12/2023]
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) has emerged as a novel means for sensitive detection of dilute labile protons and chemical exchange rates. By sensitizing to pH-dependent chemical exchange, CEST MRI has shown promising results in monitoring tissue statuses such as pH changes in disorders like acute stroke, tumor, and acute kidney injury. This article briefly reviews the basic principles for CEST imaging and quantitative measures, from the simplistic asymmetry analysis to multipool Lorentzian decoupling and quasi-steady-state reconstruction. In particular, the advantages and limitations of commonly used quantitative approaches for CEST applications are discussed.
Collapse
Affiliation(s)
- Takahiro Igarashi
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA
| | - Hahnsung Kim
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA
| |
Collapse
|
3
|
Mueller S, Scheffler K, Zaiss M. On the interference from agar in chemical exchange saturation transfer MRI parameter optimization in model solutions. NMR IN BIOMEDICINE 2021; 34:e4403. [PMID: 32929815 DOI: 10.1002/nbm.4403] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 08/10/2020] [Accepted: 08/14/2020] [Indexed: 06/11/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is currently set to become part of clinical routine as it enables indirect detection of low concentrated molecules and proteins. Recently, intermediate to fast exchanging functional groups of glucose and its derivatives, glutamate and dextran, have gained attention as promising CEST contrast agents. To increase the specificity of CEST MRI for certain functional groups, the presaturation module is commonly optimized. At an early stage, this is performed in well-defined model solutions, in which, for instance, the relaxation times are adjusted to mimic in vivo conditions. This often involves agar, assuming the substance would not yield significant CEST effects by itself, which the current study proves to be an invalid assumption. Model solutions at different pH values and concentrations of agar were investigated at different temperatures at a 9.4 T human whole body MR scanner. High power presaturation of around 4 μT, optimal for investigating intermediate to fast exchanging groups, was applied. Postprocessing included spatiotemporal corrections for B0 and spatial corrections for B1+ . CEST effects of up to 3 % of the bulk water signal were observed. From pH, concentration and temperature dependency, it was concluded that the observed behavior reflects a CEST effect of agar. It was also shown how to remove this undesirable contribution from CEST MRI data. It was concluded that if agar is involved in the CEST MRI parameter optimization process, its contribution to the observed effects has to be taken into account. CEST agent concentration must be sufficiently high to be able to neglect the contribution of agar, or a control sample at matched pH is necessary for correction. Experiments on pure agarose showed reduced CEST effects compared with agar but did not provide a neutral baseline either.
Collapse
Affiliation(s)
- Sebastian Mueller
- High-field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
| | - Klaus Scheffler
- High-field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- Department of Biomedical Magnetic Resonance, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Moritz Zaiss
- High-field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany
- Department of Neuroradiology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
4
|
Tomar JS, Shen J. Characterization of Carbonic Anhydrase In Vivo Using Magnetic Resonance Spectroscopy. Int J Mol Sci 2020; 21:E2442. [PMID: 32244610 PMCID: PMC7178054 DOI: 10.3390/ijms21072442] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 03/29/2020] [Accepted: 03/30/2020] [Indexed: 01/30/2023] Open
Abstract
Carbonic anhydrase is a ubiquitous metalloenzyme that catalyzes the reversible interconversion of CO2/HCO3-. Equilibrium of these species is maintained by the action of carbonic anhydrase. Recent advances in magnetic resonance spectroscopy have allowed, for the first time, in vivo characterization of carbonic anhydrase in the human brain. In this article, we review the theories and techniques of in vivo 13C magnetization (saturation) transfer magnetic resonance spectroscopy as they are applied to measuring the rate of exchange between CO2 and HCO3- catalyzed by carbonic anhydrase. Inhibitors of carbonic anhydrase have a wide range of therapeutic applications. Role of carbonic anhydrases and their inhibitors in many diseases are also reviewed to illustrate future applications of in vivo carbonic anhydrase assessment by magnetic resonance spectroscopy.
Collapse
Affiliation(s)
| | - Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, NIH, Bethesda, MD 20892, USA
| |
Collapse
|
5
|
Simegn GL, Van der Kouwe AJW, Robertson FC, Meintjes EM, Alhamud A. Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs). Magn Reson Med 2018; 81:2600-2613. [PMID: 30506877 DOI: 10.1002/mrm.27597] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Revised: 10/13/2018] [Accepted: 10/16/2018] [Indexed: 11/11/2022]
Abstract
PURPOSE CEST MRI allows for indirect detection of molecules with exchangeable protons, measured as a reduction in water signal because of continuous transfer of saturated protons. CEST requires saturation pulses on the order of a second, as well as repeated acquisitions at different offset frequencies. The resulting extended scan time makes CEST susceptible to subject motion, which introduces field inhomogeneity, shifting offset frequencies and causing distortions in CEST spectra that resemble true CEST effects. This is a particular problem for molecules that resonate close to water, such as hydroxyl group in glycogen. To address this, a technique for real-time measurement and correction of motion and field inhomogeneity is proposed. METHODS A CEST sequence was modified to include double volumetric navigators (DvNavs) for real-time simultaneous motion and shim correction. Phantom tests were conducted to investigate the effects of motion and shim changes on CEST quantification and to validate the accuracy of DvNav motion and shim estimates. To evaluate DvNav shim and motion correction in vivo, acquisitions including 5 experimental conditions were performed in the calf muscle of 2 volunteers. RESULTS Phantom data show that DvNav-CEST accurately estimates frequency and linear gradient changes because of motion and corrects resulting image distortions. In addition, DvNav-CEST improves CEST quantification in vivo in the presence of motion. CONCLUSION The proposed technique allows for real-time simultaneous motion and shim correction with no additional scanning time, enabling accurate CEST quantification even in the presence of motion and field inhomogeneity.
Collapse
Affiliation(s)
- Gizeaddis L Simegn
- UCT Medical Imaging Research Unit, Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | - Andre J W Van der Kouwe
- UCT Medical Imaging Research Unit, Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Cape Town, South Africa.,Athinoula A. Martinos Center for Biomedical Imaging/MGH, Charlestown, Massachusetts.,Department of Radiology, Harvard Medical School, Boston, Massachusetts
| | - Frances C Robertson
- UCT Medical Imaging Research Unit, Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Cape Town, South Africa.,Cape Universities Body Imaging Centre (CUBIC-UCT), Cape Town, South Africa
| | - Ernesta M Meintjes
- UCT Medical Imaging Research Unit, Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Cape Town, South Africa.,Cape Universities Body Imaging Centre (CUBIC-UCT), Cape Town, South Africa
| | - Ali Alhamud
- UCT Medical Imaging Research Unit, Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Cape Town, South Africa.,Cape Universities Body Imaging Centre (CUBIC-UCT), Cape Town, South Africa
| |
Collapse
|
6
|
Righi V, Starkey M, Dai G, Rahme LG, Tzika AA. Magnetization transfer contrast MRI in GFP‑tagged live bacteria. Mol Med Rep 2018; 19:617-621. [PMID: 30483743 PMCID: PMC6297796 DOI: 10.3892/mmr.2018.9669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 05/22/2018] [Indexed: 11/29/2022] Open
Abstract
Green fluorescent protein (GFP) is a widely utilized molecular reporter of gene expression. However, its use in in vivo imaging has been restricted to transparent tissue mainly due to the tissue penetrance limitation of optical imaging. Magnetization transfer contrast (MTC) is a magnetic resonance imaging (MRI) methodology currently utilized to detect macromolecule changes such as decrease in myelin and increase in collagen content. MTC MRI imaging was performed to detect GFP in both in vitro cells and in an in vivo mouse model to determine if MTC imaging could be used to detect infection from Pseudomonas aeruginosa in murine tissues. It was demonstrated that the approach produces values that are protein specific and concentration dependent. This method provides a valuable, non-invasive imaging tool to study the impact of novel antibacterial therapeutics on bacterial proliferation and perhaps viability within the host system, and could potentially suggest the modulation of bacterial gene expression within the host when exposed to such compounds.
Collapse
Affiliation(s)
- Valeria Righi
- NMR Surgical Laboratory, Department of Surgery, Massachusetts General Hospital and Shriners Burns Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Melissa Starkey
- Molecular Surgery Laboratory, Department of Surgery, Massachusetts General Hospital and Shriners Burns Institute, Harvard Medical School, Boston, MA 02114, USA
| | - George Dai
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Boston, MA 02114, USA
| | - Laurence G Rahme
- Molecular Surgery Laboratory, Department of Surgery, Massachusetts General Hospital and Shriners Burns Institute, Harvard Medical School, Boston, MA 02114, USA
| | - Aria A Tzika
- NMR Surgical Laboratory, Department of Surgery, Massachusetts General Hospital and Shriners Burns Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
7
|
Ren J, Sherry AD, Malloy CR. A simple approach to evaluate the kinetic rate constant for ATP synthesis in resting human skeletal muscle at 7 T. NMR IN BIOMEDICINE 2016; 29:1240-8. [PMID: 25943328 PMCID: PMC4673044 DOI: 10.1002/nbm.3310] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Revised: 03/25/2015] [Accepted: 03/27/2015] [Indexed: 05/11/2023]
Abstract
Inversion transfer (IT) is a well-established technique with multiple attractive features for analysis of kinetics. However, its application in measurement of ATP synthesis rate in vivo has lagged behind the more common saturation transfer (ST) techniques. One well-recognized issue with IT is the complexity of data analysis in comparison with much simpler analysis by ST. This complexity arises, in part, because the γ-ATP spin is involved in multiple chemical reactions and magnetization exchanges, whereas Pi is involved in a single reaction, Pi → γ-ATP. By considering the reactions involving γ-ATP only as a lumped constant, the rate constant for the reaction of physiological interest, kPi→γATP , can be determined. Here, we present a new IT data analysis method to evaluate kPi→γATP using data collected from resting human skeletal muscle at 7 T. The method is based on the basic Bloch-McConnell equation, which relates kPi→γATP to m˙Pi, the rate of Pi magnetization change. The kPi→γATP value is accessed from m˙Pi data by more familiar linear correlation approaches. For a group of human subjects (n = 15), the kPi→γATP value derived for resting calf muscle was 0.066 ± 0.017 s(-1) , in agreement with literature-reported values. In this study we also explored possible time-saving strategies to speed up data acquisition for kPi→γATP evaluation using simulations. The analysis indicates that it is feasible to carry out a (31) P IT experiment in about 10 min or less at 7 T with reasonable outcome in kPi→γATP variance for measurement of ATP synthesis in resting human skeletal muscle. We believe that this new IT data analysis approach will facilitate the wide acceptance of IT to evaluate ATP synthesis rate in vivo. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX75390
- VA North Texas Health Care System, Dallas, TX75216
| |
Collapse
|
8
|
Clark DJ, Smith AK, Dortch RD, Knopp MV, Smith SA. Investigating hydroxyl chemical exchange using a variable saturation power chemical exchange saturation transfer (vCEST) method at 3 T. Magn Reson Med 2016; 76:826-37. [PMID: 26414937 PMCID: PMC4809798 DOI: 10.1002/mrm.25987] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 08/21/2015] [Accepted: 08/24/2015] [Indexed: 12/22/2022]
Abstract
PURPOSE To develop a chemical exchange saturation transfer (CEST) scheme sensitive to hydroxyl protons at 3 T. Clinical imaging of hydroxyl moieties can have an impact on osteoarthritis, neuropsychiatric disorders, and cancer. THEORY By varying saturation amplitude linearly with frequency offset, the direct water saturation component of the Z-spectrum is flattened and can be subtracted to produce a magnetization transfer ratio difference spectrum (MTRdiff ) that isolates solute resonances. Variable saturation power allows for near optimization of hydroxyl and amine/amide moieties in one Z-spectrum. METHODS Phantom studies were used to test vCEST performance in two environments: (1) aqueous single-solute (glycogen, glucose); (2) aqueous multiple solute (glycogen with bovine serum albumin). In vivo vCEST imaging of glycosaminoglycan content in patellar-femoral cartilage was performed in a subject with history of cartilage transplant. RESULTS In solutions with overlapping resonances, vCEST resolves separate hydroxyl and amine/amide peaks. CEST hydroxyl signal in cartilage is negligible, but with vCEST, hydroxyl signal ranged from 2 to 5% ppm and showed distinct contrast between lesions and normal appearing cartilage. CONCLUSION Introduced a variable saturation amplitude CEST (vCEST) scheme to improve sensitivity to exchangeable hydroxyl moieties at 3 T resulting in detection of hydroxyl in the presence of multiple solutes with overlapping resonances. Magn Reson Med 76:826-837, 2016. © 2015 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Daniel James Clark
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
- Wright Center of Innovation, The Ohio State University, Columbus, Ohio, USA
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA
| | - Alex K Smith
- Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Richard D Dortch
- Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee, USA
| | - Michael V Knopp
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
- Wright Center of Innovation, The Ohio State University, Columbus, Ohio, USA
| | - Seth A Smith
- Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee, USA
| |
Collapse
|
9
|
Baguet E. Refinement of the inversion-transfer NMR experiment for faster characterization of chemical exchange. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2016; 54:51-57. [PMID: 26303323 DOI: 10.1002/mrc.4320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Revised: 07/16/2015] [Accepted: 07/23/2015] [Indexed: 06/04/2023]
Abstract
It is shown theoretically that the inversion-transfer experiment used to estimate the value of unidirectional rate constants in chemical exchange systems can be performed faster via a reduction of the recovery delay. The chemical exchange rate constants can then be estimated accurately with a formula close to that of standard inversion transfer and easy to use, after a justified approximation. A function was developed to determine the optimal value of the recovery delay for an optimal inversion-transfer sequence. The validity of these theoretical results was checked experimentally with a solution of N,N-dimethylacetamide in which chemical exchange arises from internal hindered rotation.
Collapse
Affiliation(s)
- Evelyne Baguet
- CEISAM CNRS UMR 6230, Département de Chimie, Université de Nantes, 2 rue de la Houssiniére, F-44322 Nantes cedex 3, France
| |
Collapse
|
10
|
Ren J, Sherry AD, Malloy CR. Amplification of the effects of magnetization exchange by (31) P band inversion for measuring adenosine triphosphate synthesis rates in human skeletal muscle. Magn Reson Med 2015; 74:1505-14. [PMID: 25469992 PMCID: PMC4792267 DOI: 10.1002/mrm.25514] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 09/23/2014] [Accepted: 10/09/2014] [Indexed: 01/06/2023]
Abstract
PURPOSE The goal of this study was to amplify the effects of magnetization exchange between γ-adenosine triphosphate (ATP) and inorganic phosphate (Pi) for evaluation of ATP synthesis rates in human skeletal muscle. METHODS The strategy works by simultaneously inverting the (31) P resonances of phosphocreatine (PCr) and ATP using a wide bandwidth, adiabatic inversion radiofrequency pulse followed by observing dynamic changes in intensity of the noninverted Pi signal versus the delay time between the inversion and observation pulses. This band inversion technique significantly delays recovery of γ-ATP magnetization; consequently, the exchange reaction, Pi ↔ γ-ATP, is readily detected and easily analyzed. RESULTS The ATP synthesis rate measured from high-quality spectral data using this method was 0.073 ± 0.011 s(-1) in resting human skeletal muscle (N = 10). The T1 of Pi was 6.93 ± 1.90 s, consistent with the intrinsic T1 of Pi at this field. The apparent T1 of γ-ATP was 4.07 ± 0.32 s, about two-fold longer than its intrinsic T1 due to storage of magnetization in PCr. CONCLUSION Band inversion provides an effective method to amplify the effects of magnetization transfer between γ-ATP and Pi. The resulting data can be easily analyzed to obtain the ATP synthesis rate using a two-site exchange model.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX75390
- VA North Texas Health Care System, Dallas, TX75216
| |
Collapse
|
11
|
Ren J, Sherry AD, Malloy CR. (31)P-MRS of healthy human brain: ATP synthesis, metabolite concentrations, pH, and T1 relaxation times. NMR IN BIOMEDICINE 2015; 28:1455-62. [PMID: 26404723 PMCID: PMC4772768 DOI: 10.1002/nbm.3384] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 07/22/2015] [Accepted: 07/24/2015] [Indexed: 05/18/2023]
Abstract
The conventional method for measuring brain ATP synthesis is (31)P saturation transfer (ST), a technique typically dependent on prolonged pre-saturation with γ-ATP. In this study, ATP synthesis rate in resting human brain is evaluated using EBIT (exchange kinetics by band inversion transfer), a technique based on slow recovery of γ-ATP magnetization in the absence of B1 field following co-inversion of PCr and ATP resonances with a short adiabatic pulse. The unidirectional rate constant for the Pi → γ-ATP reaction is 0.21 ± 0.04 s(-1) and the ATP synthesis rate is 9.9 ± 2.1 mmol min(-1) kg(-1) in human brain (n = 12 subjects), consistent with the results by ST. Therefore, EBIT could be a useful alternative to ST in studying brain energy metabolism in normal physiology and under pathological conditions. In addition to ATP synthesis, all detectable (31)P signals are analyzed to determine the brain concentration of phosphorus metabolites, including UDPG at around 10 ppm, a previously reported resonance in liver tissues and now confirmed in human brain. Inversion recovery measurements indicate that UDPG, like its diphosphate analogue NAD, has apparent T1 shorter than that of monophosphates (Pi, PMEs, and PDEs) but longer than that of triphosphate ATP, highlighting the significance of the (31)P-(31)P dipolar mechanism in T1 relaxation of polyphosphates. Another interesting finding is the observation of approximately 40% shorter T1 for intracellular Pi relative to extracellular Pi, attributed to the modulation by the intracellular phosphoryl exchange reaction Pi ↔ γ-ATP. The sufficiently separated intra- and extracellular Pi signals also permit the distinction of pH between intra- and extracellular environments (pH 7.0 versus pH 7.4). In summary, quantitative (31)P MRS in combination with ATP synthesis, pH, and T1 relaxation measurements may offer a promising tool to detect biochemical alterations at early stages of brain dysfunctions and diseases.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
| | - A. Dean Sherry
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Chemistry, University of Texas at Dallas, Richardson, TX 75080
| | - Craig R. Malloy
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390
- VA North Texas Health Care System, Dallas, TX 75216
- To whom correspondence should be addressed: Craig R. Malloy, 5323 Harry Hines Blvd, NE4.2, Dallas, Texas 75390-8568, USA, (214) 645-2722,
| |
Collapse
|
12
|
Kim J, Wu Y, Guo Y, Zheng H, Sun PZ. A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging. CONTRAST MEDIA & MOLECULAR IMAGING 2015; 10:163-178. [PMID: 25641791 DOI: 10.1002/cmmi.1628] [Citation(s) in RCA: 86] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 08/26/2014] [Accepted: 09/10/2014] [Indexed: 01/10/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile imaging method that probes the chemical exchange between bulk water and exchangeable protons. CEST imaging indirectly detects dilute labile protons via bulk water signal changes following selective saturation of exchangeable protons, which offers substantial sensitivity enhancement and has sparked numerous biomedical applications. Over the past decade, CEST imaging techniques have rapidly evolved owing to contributions from multiple domains, including the development of CEST mathematical models, innovative contrast agent designs, sensitive data acquisition schemes, efficient field inhomogeneity correction algorithms, and quantitative CEST (qCEST) analysis. The CEST system that underlies the apparent CEST-weighted effect, however, is complex. The experimentally measurable CEST effect depends not only on parameters such as CEST agent concentration, pH and temperature, but also on relaxation rate, magnetic field strength and more importantly, experimental parameters including repetition time, RF irradiation amplitude and scheme, and image readout. Thorough understanding of the underlying CEST system using qCEST analysis may augment the diagnostic capability of conventional imaging. In this review, we provide a concise explanation of CEST acquisition methods and processing algorithms, including their advantages and limitations, for optimization and quantification of CEST MRI experiments.
Collapse
Affiliation(s)
- Jinsuh Kim
- Department of Radiology, University of Iowa, Iowa City, IA, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Yingkun Guo
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Key Laboratory for MRI, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| |
Collapse
|
13
|
Ren J, Yang B, Sherry AD, Malloy CR. Exchange kinetics by inversion transfer: integrated analysis of the phosphorus metabolite kinetic exchanges in resting human skeletal muscle at 7 T. Magn Reson Med 2014; 73:1359-69. [PMID: 24733433 DOI: 10.1002/mrm.25256] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2013] [Revised: 03/06/2014] [Accepted: 03/26/2014] [Indexed: 01/06/2023]
Abstract
PURPOSE To develop an inversion pulse-based, chemical exchange saturation transfer-like method for detection of (31) P magnetization exchanges among all nuclear magnetic resonance visible metabolites suitable for providing an integrated kinetic analysis of phosphorus exchange reactions in vivo. METHODS The exchange kinetics by inversion transfer (EKIT) sequence includes application of a frequency-selective inversion pulse arrayed over the range of relevant (31) P frequencies, followed by a constant delay and a hard readout pulse. A series of EKIT spectra, each given by a plot of Z-magnetization for each metabolite of interest versus frequency of the inversion pulse, can be generated from this single data set. RESULTS EKIT spectra reflect chemical exchange due to known biochemical reactions, cross-relaxation effects, and relayed magnetization transfers due to both processes. The rate constants derived from EKIT data collected on resting human skeletal muscle were: ATP synthesis via ATP synthase (0.050 ± 0.016 s(-1) ), ATP synthesis via creatine kinase (0.264 ± 0.023 s(-1) ), and cross-relaxation between neighboring spin pairs within ATP (0.164 ± 0.022 s(-1) ). CONCLUSION EKIT provides a simple, alternative method to detect chemical exchange, cross relaxation, and relayed magnetization transfer effects in human skeletal muscle at 7 T.
Collapse
Affiliation(s)
- Jimin Ren
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | | | | | | |
Collapse
|
14
|
Zaiss M, Bachert P. Chemical exchange saturation transfer (CEST) and MRZ-spectroscopyin vivo: a review of theoretical approaches and methods. Phys Med Biol 2013; 58:R221-69. [DOI: 10.1088/0031-9155/58/22/r221] [Citation(s) in RCA: 216] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
15
|
Sun PZ, Wang Y, Xiao G, Wu R. Simultaneous experimental determination of labile proton fraction ratio and exchange rate with irradiation radio frequency power-dependent quantitative CEST MRI analysis. CONTRAST MEDIA & MOLECULAR IMAGING 2013; 8:246-51. [PMID: 23606428 DOI: 10.1002/cmmi.1524] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Revised: 11/22/2012] [Accepted: 11/26/2012] [Indexed: 12/20/2022]
Abstract
Chemical exchange saturation transfer (CEST) imaging is sensitive to dilute proteins/peptides and microenvironmental properties, and has been increasingly evaluated for molecular imaging and in vivo applications. However, the experimentally measured CEST effect depends on the CEST agent concentration, exchange rate and relaxation time. In addition, there may be non-negligible direct radio-frequency (RF) saturation effects, particularly severe for diamagnetic CEST (DIACEST) agents owing to their relatively small chemical shift difference from that of the bulk water resonance. As such, the commonly used asymmetry analysis only provides CEST-weighted information. Recently, it has been shown with numerical simulation that both labile proton concentration and exchange rate can be determined by evaluating the RF power dependence of DIACEST effect. To validate the simulation results, we prepared and imaged two CEST phantoms: a pH phantom of serially titrated pH at a fixed creatine concentration and a concentration phantom of serially varied creatine concentration titrated to the same pH, and solved the labile proton fraction ratio and exchange rate per-pixel. For the concentration phantom, we showed that the labile proton fraction ratio is proportional to the CEST agent concentration with negligible change in the exchange rate. Additionally, we found the exchange rate of the pH phantom is dominantly base-catalyzed with little difference in the labile proton fraction ratio. In summary, our study demonstrated quantitative DIACEST MRI, which remains promising to augment the conventional CEST-weighted MRI analysis.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | | | | | | |
Collapse
|
16
|
Sun PZ, Lu J, Wu Y, Xiao G, Wu R. Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity. Phys Med Biol 2013; 58:N229-40. [PMID: 23939228 DOI: 10.1088/0031-9155/58/17/n229] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Chemical exchange saturation transfer (CEST) is a magnetic resonance imaging (MRI) contrast mechanism that can detect dilute CEST agents and microenvironmental properties, with a host of promising applications. Experimental measurement of the CEST effect is complex, and depends on not only CEST agent concentration and exchange rate, but also experimental parameters such as RF irradiation amplitude and scheme. Although echo planar imaging (EPI) has been increasingly used for CEST MRI, the relationship between CEST effect and repetition time (TR), RF irradiation duty cycle (DC) and EPI flip angle (α) has not been fully evaluated and optimized to enhance CEST MRI sensitivity. In addition, our study evaluated gradient echo CEST-EPI by quantifying the CEST effect and its signal-to-noise ratio per unit time (SNRput) as functions of TR, DC and α. We found that CEST effect increased with TR and DC but decreased with α. Importantly, we found that SNRput peaked at intermediate TRs of about twice the T1 and α, at approximately 75°, and increased with RF DC. The simulation results were validated using a dual-pH creatine-gel CEST phantom. In summary, our study provides a useful framework for optimizing CEST MRI experiments.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA.
| | | | | | | | | |
Collapse
|
17
|
Zaiss M, Bachert P. Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange -- modeling off-resonant spin-lock and chemical exchange saturation transfer. NMR IN BIOMEDICINE 2013; 26:507-18. [PMID: 23281186 DOI: 10.1002/nbm.2887] [Citation(s) in RCA: 168] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 10/08/2012] [Accepted: 10/09/2012] [Indexed: 05/17/2023]
Abstract
Chemical exchange observed by NMR saturation transfer (CEST) and spin-lock (SL) experiments provide an MRI contrast by indirect detection of exchanging protons. The determination of the relative concentrations and exchange rates is commonly achieved by numerical integration of the Bloch-McConnell equations. We derive an analytical solution of the Bloch-McConnell equations that describes the magnetization of coupled spin populations under radiofrequency irradiation. As CEST and off-resonant SL are equivalent, their steady-state magnetization and dynamics can be predicted by the same single eigenvalue: the longitudinal relaxation rate in the rotating frame R1ρ . For the case of slowly exchanging systems, e.g. amide protons, the saturation of the small proton pool is affected by transverse relaxation (R2b ). It turns out, that R2b is also significant for intermediate exchange, such as amine- or hydroxyl-exchange or paramagnetic CEST agents, if pools are only partially saturated. We propose a solution for R1ρ that includes R2 of the exchanging pool by extending existing approaches, and verify it by numerical simulations. With the appropriate projection factors, we obtain an analytical solution for CEST and SL for nonzero R2 of the exchanging pool, exchange rates in the range 1-10(4) Hz, B1 from 0.1 to 20 μT and arbitrary chemical shift differences between the exchanging pools, whilst considering the dilution by direct water saturation across the entire Z-spectra. This allows the optimization of irradiation parameters and the quantification of pH-dependent exchange rates and metabolite concentrations. In addition, we propose evaluation methods that correct for concomitant direct saturation effects. It is shown that existing theoretical treatments for CEST are special cases of this approach.
Collapse
Affiliation(s)
- Moritz Zaiss
- Department of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
| | | |
Collapse
|
18
|
Vinogradov E, Soesbe TC, Balschi JA, Sherry AD, Lenkinski RE. pCEST: Positive contrast using Chemical Exchange Saturation Transfer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2012; 215:64-73. [PMID: 22237630 PMCID: PMC3288637 DOI: 10.1016/j.jmr.2011.12.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 12/13/2011] [Accepted: 12/14/2011] [Indexed: 05/11/2023]
Abstract
Chemical Exchange Saturation Transfer (CEST) contrast utilizes selective pre-saturation of a small pool of exchanging protons and subsequent detection of the decrease in bulk water signal. The CEST contrast is negative and requires detection of small signal change in the presence of a strong background signal. Here we develop a Positive CEST (pCEST) detection scheme utilizing the analogous nature of the CEST and off-resonance T(1)(ρ) experiments and exploring increased apparent relaxation rates in the presence of the selective pre-saturation. pCEST leads to the positive contrast, i.e., increased signal intensity as the result of the presence of the agent and RF pre-saturation. Simultaneously substantial background suppression is achieved. The contrast can be switched "ON" and "OFF", similar to the original CEST.
Collapse
Affiliation(s)
- Elena Vinogradov
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | |
Collapse
|
19
|
Song X, Gilad AA, Joel S, Liu G, Bar-Shir A, Liang Y, Gorelik M, Pekar JJ, van Zijl PCM, Bulte JWM, McMahon MT. CEST phase mapping using a length and offset varied saturation (LOVARS) scheme. Magn Reson Med 2012; 68:1074-86. [PMID: 22246684 DOI: 10.1002/mrm.23312] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2011] [Revised: 10/11/2011] [Accepted: 11/08/2011] [Indexed: 02/04/2023]
Abstract
Chemical exchange saturation transfer MRI is a promising new technique for cellular and molecular imaging. This contrast allows the detection of tumors and ischemia without the use of gadolinium as well as the design of microenvironment-sensitive probes that can be discriminated based on their exchange contrast properties and saturation frequency. Current acquisition schemes to detect and analyze this contrast suffer from sensitivity to spatial B0 inhomogeneity and low contrast-to-noise-ratio, which is an obstacle to widespread adoption of the technology. A new method to detect chemical exchange saturation transfer contrast is proposed here, termed "length and offset varied saturation" which acquires a set of images with the saturation parameters varied so as to modulate the exchange contrast. Either fast fourier transform or the general linear model can be employed to decompose the modulation patterns into separate sources of water signal loss. After transformation, a length and offset varied saturation phase map is generated, which is insensitive to B0 inhomogeneity. When collected on live mice bearing 9L gliosarcomas, and compared to the conventional asymmetry in the magnetization transfer ratio map using offset increment correction, the results show that length and offset varied saturation phase mapping obtains about three to four times contrast-to-noise-ratio and exhibits less B0 artifacts.
Collapse
Affiliation(s)
- Xiaolei Song
- Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Zaiss M, Schmitt B, Bachert P. Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 211:149-55. [PMID: 21641247 DOI: 10.1016/j.jmr.2011.05.001] [Citation(s) in RCA: 215] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2011] [Revised: 04/26/2011] [Accepted: 05/09/2011] [Indexed: 05/24/2023]
Abstract
Chemical exchange saturation transfer (CEST) processes in aqueous systems are quantified by evaluation of z-spectra, which are obtained by acquisition of the water proton signal after selective RF presaturation at different frequencies. When saturation experiments are performed in vivo, three effects are contributing: CEST, direct water saturation (spillover), and magnetization transfer (MT) mediated by protons bound to macromolecules and bulk water molecules. To analyze the combined saturation a new analytical model is introduced which is based on the weak-saturation-pulse (WSP) approximation. The model combines three single WSP approaches to a general model function. Simulations demonstrated the benefits and constraints of the model, in particular the capability of the model to reproduce the ideal proton transfer rate (PTR) and the conventional MT rate for moderate spillover effects (up to 50% direct saturation at CEST-resonant irradiation). The method offers access to PTR from z-spectra data without further knowledge of the system, but requires precise measurements with dense saturation frequency sampling of z-spectra. PTR is related to physical parameters such as concentration, transfer rates and thereby pH or temperature of tissue, using either exogenous contrast agents (PARACEST, DIACEST) or endogenous agents such as amide protons and -OH protons of small metabolites.
Collapse
Affiliation(s)
- Moritz Zaiss
- Department of Medical Physics in Radiology, Deutsches Krebsforschungszentrum (DKFZ, German Cancer Research Center), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany.
| | | | | |
Collapse
|
21
|
Schär M, El-Sharkawy AMM, Weiss RG, Bottomley PA. Triple repetition time saturation transfer (TRiST) 31P spectroscopy for measuring human creatine kinase reaction kinetics. Magn Reson Med 2010; 63:1493-501. [PMID: 20512852 DOI: 10.1002/mrm.22347] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Human cardiac phosphorus MR saturation transfer experiments to quantify creatine kinase forward rate constants (k(f)) have previously been performed at 1.5 T. Such experiments could benefit from increased signal-to-noise ratio (SNR) and spectral resolution at 3 T. At 1.5 T, the four-angle saturation transfer method was applied with low-angle adiabatic pulses and surface coils. However, low-angle adiabatic pulses are potentially problematic above 1.5 T due to bandwidth limitations, power requirements, power deposition, and intrapulse spin-spin relaxation. For localized metabolite spin-lattice relaxation time (T(1)) measurements, a dual repetition time approach with adiabatic half-passage pulses was recently introduced to solve these problems at 3 T. Because the saturation transfer experiment requires a T(1) measurement performed while one reacting moiety is saturated, we adapt the dual repetition time approach to measure k(f) using a triple repetition time saturation transfer (TRiST) method. A new pulsed saturation scheme with reduced sensitivity to static magnetic field inhomogeneity and compatibility with cardiac triggering is also presented. TRiST measurements of k(f) are validated in human calf muscle against conventional saturation transfer and found to agree within 3%. The first 3-T TRiST measurements of creatine kinase k(f) in the human calf (n = 6), chest muscle, and heart (n = 8) are 0.26 +/- 0.04 s(-1), 0.23 +/- 0.03 s(-1), and 0.32 +/- 0.07 s(-1), respectively, consistent with prior 1.5 T values.
Collapse
Affiliation(s)
- Michael Schär
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, USA.
| | | | | | | |
Collapse
|
22
|
Viswanathan S, Kovacs Z, Green KN, Ratnakar SJ, Sherry AD. Alternatives to gadolinium-based metal chelates for magnetic resonance imaging. Chem Rev 2010; 110:2960-3018. [PMID: 20397688 PMCID: PMC2874212 DOI: 10.1021/cr900284a] [Citation(s) in RCA: 310] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Subha Viswanathan
- Advanced Imaging Research Center, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390 and Department of Chemistry, University of Texas at Dallas, 800 West Campbell Road, Richardson, Texas 75080
| | - Zoltan Kovacs
- Advanced Imaging Research Center, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390 and Department of Chemistry, University of Texas at Dallas, 800 West Campbell Road, Richardson, Texas 75080
| | - Kayla N. Green
- Advanced Imaging Research Center, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390 and Department of Chemistry, University of Texas at Dallas, 800 West Campbell Road, Richardson, Texas 75080
| | - S. James Ratnakar
- Advanced Imaging Research Center, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390 and Department of Chemistry, University of Texas at Dallas, 800 West Campbell Road, Richardson, Texas 75080
| | - A. Dean Sherry
- Advanced Imaging Research Center, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, Texas 75390 and Department of Chemistry, University of Texas at Dallas, 800 West Campbell Road, Richardson, Texas 75080
| |
Collapse
|
23
|
Sun PZ. Simultaneous determination of labile proton concentration and exchange rate utilizing optimal RF power: Radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 202:155-61. [PMID: 19926319 PMCID: PMC2818407 DOI: 10.1016/j.jmr.2009.10.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2009] [Revised: 10/26/2009] [Accepted: 10/28/2009] [Indexed: 05/11/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. However, CEST MRI contrast mechanism is complex, depending not only on the CEST agent concentration, exchange and relaxation properties, but also varying with experimental conditions such as magnetic field strength and RF power. Hence, it remains somewhat difficult to quantify apparent CEST MRI contrast for properties such as pH, temperature and protein content. In particular, CEST MRI is susceptible to RF spillover effects in that RF irradiation may directly saturate the bulk water MR signal, leading to an optimal RF power at which the CEST contrast is maximal. Whereas RF spillover is generally considered an adverse effect, it is noted here that the optimal RF power strongly varies with exchange rate, although with negligible dependence on labile proton concentration. An empirical solution suggested that optimal RF power may serve as a sensitive parameter for simultaneously determining the labile proton content and exchange rate, hence, allowing improved characterization of the CEST system. The empirical solution was confirmed by numerical simulation, and experimental validation is needed to further evaluate the proposed technique.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Rm 2301, 149 13th Street, Charlestown, MA 02129-2020, USA.
| |
Collapse
|
24
|
Huang CH, Morrow JR. Cerium(III), europium(III), and ytterbium(III) complexes with alcohol donor groups as chemical exchange saturation transfer agents for MRI. Inorg Chem 2009; 48:7237-43. [PMID: 19722692 DOI: 10.1021/ic900696f] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Lanthanide(III) complexes of macrocycles 1,4,7,10-tetrakis(2-hydroxyethyl)-1,4,7,10-tetraazacyclododecane (THED) and (1S,4S,7S,10S)-1,4,7,10-tetrakis(2-hydroxypropyl)-1,4,7,10-tetraazacyclododecane (S-THP) were studied as chemical exchange saturation transfer (CEST) agents for magnetic resonance imaging (MRI) applications. The four hyperfine-shifted alcohol protons of these Ln(III) complexes gave rise to a single (1)H resonance in wet d(3)-acetonitrile that was separated from the bulk water resonance (Delta omega) by 8 ppm (Ce), 2 ppm (Nd), 7 ppm (Eu), or 17 ppm (Yb). A CEST peak corresponding to the alcohol protons was observed for all Ln(THED)(3+) or Ln(S-THP)(3+) complexes except Nd(III) at low water concentrations (<1%). In 100% aqueous buffered solutions, the CEST hydroxyl peak is observed for the Eu(III), Ce(III), and Yb(III) complexes over a range of pH values. The optimal pH range for the CEST effect of each complex is related to the pK(a) of the hydroxyl/water ligands of the complex. Optimum pH values for the CEST effect from alcohol proton exchange are pH = 6.0 for Ce(S-THP)(3+), pH = 4.5 for Eu(THED)(3+), and pH = 3.0 for Yb(S-THP)(3+).
Collapse
Affiliation(s)
- Ching-Hui Huang
- Department of Chemistry, 526 Natural Sciences Complex, University at Buffalo, State University of New York, Amherst, New York 14260-3000, USA
| | | |
Collapse
|
25
|
Xu S, Shen J. Studying Enzymes by In Vivo C Magnetic Resonance Spectroscopy. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2009; 55:266-283. [PMID: 20161496 PMCID: PMC2796782 DOI: 10.1016/j.pnmrs.2009.06.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Affiliation(s)
- Su Xu
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD 20892, USA
| | | |
Collapse
|
26
|
Gabr RE, Weiss RG, Bottomley PA. Correcting reaction rates measured by saturation-transfer magnetic resonance spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2008; 191:248-258. [PMID: 18226939 PMCID: PMC2398708 DOI: 10.1016/j.jmr.2007.12.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2007] [Revised: 12/24/2007] [Accepted: 12/24/2007] [Indexed: 05/25/2023]
Abstract
Off-resonance or spillover irradiation and incomplete saturation can introduce significant errors in the estimates of chemical rate constants measured by saturation-transfer magnetic resonance spectroscopy (MRS). Existing methods of correction are effective only over a limited parameter range. Here, a general approach of numerically solving the Bloch-McConnell equations to calculate exchange rates, relaxation times and concentrations for the saturation-transfer experiment is investigated, but found to require more measurements and higher signal-to-noise ratios than in vivo studies can practically afford. As an alternative, correction formulae for the reaction rate are provided which account for the expected parameter ranges and limited measurements available in vivo. The correction term is a quadratic function of experimental measurements. In computer simulations, the new formulae showed negligible bias and reduced the maximum error in the rate constants by about 3-fold compared to traditional formulae, and the error scatter by about 4-fold, over a wide range of parameters for conventional saturation transfer employing progressive saturation, and for the four-angle saturation-transfer method applied to the creatine kinase (CK) reaction in the human heart at 1.5 T. In normal in vivo spectra affected by spillover, the correction increases the mean calculated forward CK reaction rate by 6-16% over traditional and prior correction formulae.
Collapse
Affiliation(s)
- Refaat E Gabr
- Division of MR Research, Department of Radiology, The Johns Hopkins University, JHOC 4221, Baltimore, MD 21287, USA
| | | | | |
Collapse
|
27
|
Sun PZ, Farrar CT, Sorensen AG. Correction for artifacts induced by B(0) and B(1) field inhomogeneities in pH-sensitive chemical exchange saturation transfer (CEST) imaging. Magn Reson Med 2008; 58:1207-15. [PMID: 17969015 DOI: 10.1002/mrm.21398] [Citation(s) in RCA: 128] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Chemical exchange saturation transfer (CEST) imaging provides an indirect detection mechanism that allows quantification of certain labile groups unobservable using conventional MRI. Recently, amide proton transfer (APT) imaging, a variant form of CEST imaging, has been shown capable of detecting lactic acidosis during acute ischemia, providing information complementary to that of perfusion and diffusion MRI. However, CEST contrast is usually small, and therefore, it is important to optimize experimental conditions for reliable and quantitative CEST imaging. In particular, CEST imaging is sensitive to B(0) and B(1) field, while on the other hand; field inhomogeneities persist despite recent advances in magnet technologies, especially for in vivo imaging at high fields. Consequently, correction algorithms that can compensate for field inhomogeneity-induced measurement errors in CEST imaging might be very useful. In this study, the dependence of CEST contrast on field distribution was solved and a correction algorithm was developed to compensate for field inhomogeneity-induced CEST imaging artifacts. In addition, the proposed algorithm was verified with both numerical simulation and experimental measurements, and showed nearly complete correction of CEST imaging measurement errors caused by moderate field inhomogeneity.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts, USA.
| | | | | |
Collapse
|
28
|
Kövér KE, Groves P, Jiménez-Barbero J, Batta G. Molecular Recognition and Screening Using a15N Group Selective STD NMR Method. J Am Chem Soc 2007; 129:11579-82. [PMID: 17722925 DOI: 10.1021/ja073291l] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We present a novel saturation transfer difference (STD) experiment where group selective (GS) saturation of amide protons in (15)N labeled hosts is achieved. It is demonstrated that a train of BIRD(d) pulses that inverts only protons attached to (15)N indeed results in saturation of the amide protons, while the background proton magnetization is much less affected. The undesired effect of partial saturation of the unlabeled protons can be completely cancelled out in difference spectra by switching the (15)N carrier between the on- and the off-resonance frequencies. As a result, clean and artifact-free STD spectra are obtained without the need of time-consuming optimization of experimental parameters and acquiring control spectra in the absence of the host. The use of the (15)N-GS STD experiment is demonstrated for the case of a glycopeptide antibiotic (dimeric eremomycin)-cell-wall analogue peptide (N-Ac-D-Ala) model system where the host and guest (1)H signals overlap. The application seems feasible for ligand screening against proteins without the prerequisite of a clean on-resonance frequency or defined ligand library. The new experiment can be used as the basis for studying intermolecular interactions where the standard STD experiment is difficult to optimize.
Collapse
Affiliation(s)
- Katalin E Kövér
- Department of Inorganic and Analytical Chemistry, Centre of Arts, Humanities and Sciences, University of Debrecen, Egyetem tér 1, H-4010 Debrecen, Hungary.
| | | | | | | |
Collapse
|
29
|
Sun PZ, Zhou J, Huang J, van Zijl P. Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia. Magn Reson Med 2007; 57:405-10. [PMID: 17260362 DOI: 10.1002/mrm.21151] [Citation(s) in RCA: 112] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Amide proton transfer (APT) imaging employs the chemical exchange saturation transfer (CEST) mechanism to detect mobile endogenous proteins and peptides. It can be used to detect pH reduction during acute ischemia and thus provide complementary information to perfusion-weighted (PWI) and diffusion-weighted (DWI) imaging. However, the APT contrast depends strongly on the choice of imaging parameters, especially the radiofrequency (RF) saturation time and strength, which need to be optimized. In this work it is shown that even though at least three proton pools are present, the description of the APT process during acute ischemia can be greatly simplified by means of a dual two-pool model analysis. With this approach, the experimentally measured RF irradiation power dependence of the effect in the rat brain was well predicted. The results showed an optimal RF strength of 0.75 microT for our particular coil setup, and a maximally obtainable APT ratio difference of 2.9%+/-0.3% between ischemic and normal brain regions.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA.
| | | | | | | |
Collapse
|
30
|
McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JWM, van Zijl PCM. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer. Magn Reson Med 2006; 55:836-47. [PMID: 16506187 PMCID: PMC2860536 DOI: 10.1002/mrm.20818] [Citation(s) in RCA: 257] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The ability to measure proton exchange rates in tissue using MRI would be very useful for quantitative assessment of magnetization transfer properties, both in conventional MT imaging and in the more recent chemical exchange saturation transfer (CEST) approach. CEST is a new MR contrast mechanism that depends on several factors, including the exchange rate of labile protons in the agent in a pH-dependent manner. Two new methods to monitor local exchange rate based on CEST are introduced. The two MRI-compatible approaches to measure exchange are quantifying exchange using saturation time (QUEST) dependence and quantifying exchange using saturation power (QUESP) dependence. These techniques were applied to poly-L-lysine (PLL) and a generation-5 polyamidoamine dendrimer (SPD-5) to measure the pH dependence of amide proton exchange rates in the physiologic range. Data were fit both to an analytical expression and to numerical solutions to the Bloch equations. Results were validated by comparison with exchange rates determined by two established spectroscopic methods. The exchange rates determined using the four methods were pooled for the pH-calibration curve of the agents consisting of contributions from spontaneous (k0) acid catalyzed (ka), and base catalyzed (kb) exchange rate constants. These constants were k0 = 68.9 Hz, ka = 1.21 Hz, kb = 1.92 x 10(9) Hz, and k0 = 106.4 Hz, ka = 25.8 Hz, kb = 5.45 x 10(8) Hz for PLL and SPD-5, respectively, showing the expected predominance of base-catalyzed exchange for these amide protons.
Collapse
Affiliation(s)
- Michael T. McMahon
- F. M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Assaf A. Gilad
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Institute for Cell Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jinyuan Zhou
- F. M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Phillip Z. Sun
- F. M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jeff W. M. Bulte
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Institute for Cell Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Peter C. M. van Zijl
- F. M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Correspondence to: P. C. M. van Zijl.
| |
Collapse
|
31
|
Shen J, Xu S. Theoretical analysis of carbon-13 magnetization transfer for in vivo exchange between alpha-ketoglutarate and glutamate. NMR IN BIOMEDICINE 2006; 19:248-54. [PMID: 16521093 DOI: 10.1002/nbm.1021] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Many enzymes catalyze fast exchange between a small pool and a large pool in vivo. For example, aspartate aminotransferase catalyzes fast exchanges between alpha-ketoglutarate and glutamate and between oxaloacetate and aspartate, which can be detected using in vivo(13)C MRS while saturating alpha-carbons of the keto acids. Unlike in the traditional saturation transfer experiments studied using (31)P MRS, the tricarboxylic acid cycle intermediates alpha-ketoglutarate and oxaloacetate are below the detection limit of in vivo NMR. In this work, a theoretical analysis of the saturation transfer between alpha-ketoglutarate and glutamate catalyzed by aspartate aminotransferase was presented to examine the requirements for complete saturation of the rapidly turning over alpha-ketoglutarate pool without affecting the longitudinal magnetization of glutamate. The fast turnover of the small alpha-ketoglutarate pool also allows a quasi-steady-state approximation of its dynamic longitudinal relaxation. The theoretical analysis provides a useful guide for designing experimental methods to characterize saturation transfer processes associated with fast turning over small pools in vivo.
Collapse
Affiliation(s)
- Jun Shen
- Molecular Imaging Branch, National Institute of Mental Health, Bethesda, MD 20892, USA.
| | | |
Collapse
|
32
|
Sun PZ, van Zijl PCM, Zhou J. Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2005; 175:193-200. [PMID: 15893487 DOI: 10.1016/j.jmr.2005.04.005] [Citation(s) in RCA: 136] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2005] [Revised: 04/06/2005] [Accepted: 04/07/2005] [Indexed: 05/02/2023]
Abstract
In chemical exchange dependent saturation transfer imaging experiments, exchangeable solute protons are saturated and the transfer of saturation to water is subsequently detected. When the applied irradiation power is comparable to the resonance frequency difference between the water protons and saturated solute protons, the proton transfer (PT) efficiency is reduced due to concomitant direct saturation effects. In this study, the PT process is modeled using a two-pool system. An empirical general proton transfer ratio (PTR) equation for arbitrary RF irradiation power is derived, and its optimal power to maximize the PTR is analyzed. The results are confirmed experimentally on 4.7 T using a poly-L-lysine solution. The theory provides a useful tool for optimizing the irradiation power of the PT sequences in the presence of direct saturation effects.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Division of MRI Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA.
| | | | | |
Collapse
|
33
|
Bottomley PA, Ouwerkerk R, Lee RF, Weiss RG. Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo. Magn Reson Med 2002; 47:850-63. [PMID: 11979563 PMCID: PMC1995126 DOI: 10.1002/mrm.10130] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2001] [Accepted: 01/07/2002] [Indexed: 11/09/2022]
Abstract
A new fast method of measuring kinetic reaction rates for two-site chemical exchange is described. The method employs saturation transfer magnetic resonance spectroscopy (MRS) and acquisition of only four spectra under partially saturated, high signal-to-noise ratio (SNR) conditions. In two acquisitions one of the exchanging species is saturated; the other two employ a control saturation. Each pair of acquisitions is applied with two different flip angles, and the equilibrium magnetization, relaxation times, and reaction rates are calculated therefrom. This four-angle saturation transfer (FAST) method is validated theoretically using the Bloch equations modified for two-state chemical exchange. Potential errors in the rate measurements due to the effects of exchange are evaluated for creatine kinase (CK) metabolism modeled for skeletal and heart muscle, and are found to be < 5% for forward CK flux rates of 0.05 < or = k(f) < or = 1.0 s(-1), and up to a 90% depletion of phosphocreatine (PCr). The effect of too much or too little saturating irradiation on FAST appears to be comparable to that of the conventional saturation transfer method, although the relative performance deteriorates when spillover irradiation cuts the PCr signal by 50% or more. "FASTer" and " FASTest" protocols are introduced for dynamic CK studies wherein [PCr] and/or k(f) changes. These protocols permit the omission of one or two of the four acquisitions in repeat experiments, and the missing information is recreated from initial data via a new iterative algorithm. The FAST method is validated empirically in phosphorus ((31)P) MRS studies of human calf muscle at 1.5 T. FAST measurements of 10 normal volunteers yielded the same CK reaction rates measured by the conventional method (0.29 +/- 0.06 s(-1)) in the same subjects, but an average of seven times faster. Application of the FASTer algorithm to these data correctly restored missing information within seven iterations. Finally, the FAST method was combined with 1D spatially localized (31)P MRS in a study of six volunteers, yielding the same k(f) values independent of depth, in total acquisition times of 17-39 min. These timesaving FAST methods are enabling because they permit localized measurements of metabolic flux, which were previously impractical due to intolerably long scan times.
Collapse
Affiliation(s)
- Paul A Bottomley
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21287-0843, USA.
| | | | | | | |
Collapse
|
34
|
Idiyatullin D, Daragan VA, Mayo KH. Improved measurement of (15)N-[(1)H] NOEs in the presence of H(N)-water proton chemical exchange. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2001; 153:138-143. [PMID: 11700091 DOI: 10.1006/jmre.2001.2412] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A simple method is presented to accurately determine (15)N-[(1)H] NOEs in biomolecules in the presence of H(N)-water proton chemical exchange. Three measurements are required: one with nonselective proton saturation and two with different water saturation conditions to determine the equilibrium value of the (15)N signal. This approach is exemplified with data on two peptides, one helix-forming 17-mer and one compactly folded 56-mer. Results indicate that (15)N-[(1)H] NOEs determined using the standard approach with short recycle times (3 to 4 s) can be significantly in error when H(N)-water proton chemical exchange is relatively rapid, water proton relaxation is relatively slow, and (15)N-[(1)H] NOEs are away from the value of -1. This new method avoids such inaccuracies resulting from the use of short recycle times.
Collapse
Affiliation(s)
- D Idiyatullin
- Department of Biochemistry, Molecular Biology, & Biophysics, University of Minnesota Health Sciences Center, 6-155 Jackson Hall, 321 Church Street, Minneapolis, MN 55455, USA
| | | | | |
Collapse
|
35
|
Kingsley PB, Monahan WG. Correcting for incomplete saturation and off-resonance effects in multiple-site saturation-transfer kinetic measurements. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2000; 146:100-109. [PMID: 10968962 DOI: 10.1006/jmre.2000.2124] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The effects of incomplete saturation and off-resonance irradiation on nuclear magnetic resonance saturation-transfer measurements of three-site chemical-exchange rates are discussed. A new method that uses double-saturation measurements is compared with two published methods, one that uses single-saturation measurements and one that uses a single-saturation measurement and a double-saturation measurement. Several formulas are compared for measuring the exchange rate constant k(DE) for exchange from a detected spin D to an exchanging spin E in the presence of exchange from spin D to a competing spin C. For each method, formulas are derived with corrections for incomplete saturation or off-resonance effects, with both corrections, and with neither correction. Exact formulas are available for three exchanging sites with incomplete saturation if there are no off-resonance effects. Off-resonance corrections are imperfect even with complete saturation.
Collapse
Affiliation(s)
- P B Kingsley
- Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, New York, 11030 USA.
| | | |
Collapse
|
36
|
Kingsley PB, Monahan WG. Corrections for off-resonance effects and incomplete saturation in conventional (two-site) saturation-transfer kinetic measurements. Magn Reson Med 2000; 43:810-9. [PMID: 10861875 DOI: 10.1002/1522-2594(200006)43:6<810::aid-mrm6>3.0.co;2-j] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The effects of off-resonance irradiation and incomplete saturation on saturation-transfer measurements of chemical-exchange rates are discussed. With off-resonance effects there is no exact formula for the exchange rate constant from spin D to spin E, k(DE), in terms of observable signal intensities and relaxation rates. However, k(DE) can be estimated by measuring the effective spin-lattice relaxation rate constant of spin D when spin E is saturated, *R(1), plus signal intensities with no RF irradiation, M(0D) and M(0E); with irradiation of a control position, M'(D) and M'(E); and with saturation of spin E, *M(D) and *M(E). Several formulas are compared and the best formula for calculating k(DE) appears to be either k(DE) = *R(1) [(M'(D)- *M(D))/M(0D)]/[(M'(E) - *M(E))/M(0E)], or the same formula with M(0D) and M(0E) replaced by M'(D) and M'(E). These formulas are exact with incomplete saturation and no off-resonance effects, and are better than previously published formulas when off-resonance effects are present. More accurate formulas are available if signal intensities and relaxation rates can be measured while the exchange process is stopped. Magn Reson Med 43:810-819, 2000.
Collapse
Affiliation(s)
- P B Kingsley
- Department of Radiology, North Shore University Hospital, Manhasset, New York 11030, USA.
| | | |
Collapse
|
37
|
Kingsley PB, Monahan WG. Effects of off-resonance irradiation, cross-relaxation, and chemical exchange on steady-state magnetization and effective spin-lattice relaxation times. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2000; 143:360-375. [PMID: 10729261 DOI: 10.1006/jmre.2000.2018] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In the presence of an off-resonance radiofrequency field, recovery of longitudinal magnetization to a steady state is not purely monoexponential. Under reasonable conditions with zero initial magnetization, recovery is nearly exponential and an effective relaxation rate constant R(1eff) = 1/T(1eff) can be obtained. Exact and approximate formulas for R(1eff) and steady-state magnetization are derived from the Bloch equations for spins undergoing cross-relaxation and chemical exchange between two sites in the presence of an off-resonance radiofrequency field. The relaxation formulas require that the magnetization of one spin is constant, but not necessarily zero, while the other spin relaxes. Extension to three sites with one radiofrequency field is explained. The special cases of off-resonance effects alone and with cross-relaxation or chemical exchange, cross-relaxation alone, and chemical exchange alone are compared. The inaccuracy in saturation transfer measurements of exchange rate constants by published formulas is discussed for the creatine kinase reaction. Copyright 2000 Academic Press.
Collapse
Affiliation(s)
- PB Kingsley
- Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, New York, 11030, USA
| | | |
Collapse
|