1
|
Pang Y. Deciphering adiabatic rotating frame relaxometry in biological tissues. Magn Reson Med 2024; 92:2670-2682. [PMID: 39099141 DOI: 10.1002/mrm.30240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 06/26/2024] [Accepted: 07/12/2024] [Indexed: 08/06/2024]
Abstract
PURPOSE This work aims to unravel the intricacies of adiabatic rotating frame relaxometry in biological tissues. THEORY AND METHODS The classical formalisms of dipolar relaxationR 1 ρ $$ {R}_{1\rho } $$ andR 2 ρ $$ {R}_{2\rho } $$ were systematically analyzed for water molecules reorienting on "fast" and "slow" timescales. These two timescales are, respectively, responsible for the absence and presence ofR 1 ρ $$ {R}_{1\rho } $$ dispersion. A time-averagedR 1 ρ $$ {R}_{1\rho } $$ orR 2 ρ $$ {R}_{2\rho } $$ over an adiabatic pulse duration was recast into a sum ofR 1 $$ {R}_1 $$ andR 2 $$ {R}_2 $$ , but with different weightings. These weightings depend on the specific modulations of adiabatic pulse waveforms. In this context, stretched hyperbolic secant (HSn $$ HSn $$ ) pulses were characterized. Previously publishedH S 1 $$ HS1 $$ R 1 ρ $$ {R}_{1\rho } $$ , continuous-wave (CW)R 1 ρ $$ {R}_{1\rho } $$ , andR 1 $$ {R}_1 $$ measures from 12 agarose phantoms were used to validate the theoretical predictions. A similar validation was also performed on previously publishedHSn $$ HSn $$ R 1 ρ $$ {R}_{1\rho } $$ (n $$ n $$ =1, 4, 8) andHS 1 $$ HS1 $$ R 2 ρ $$ {R}_{2\rho } $$ from bovine cartilage specimens. RESULTS Longitudinal relaxation weighting decreases forHSn $$ HSn $$ pulses asn $$ n $$ increases. Predicted CWR 1 ρ cal $$ {R}_{1\rho}^{cal} $$ values from agarose phantoms align well with the measured CWR 1 ρ exp $$ {R}_{1\rho}^{exp} $$ values, as indicated by a linear regression function:R 1 ρ cal = 1.04 * R 1 ρ exp - 1.96 $$ {R}_{1\rho}^{cal}={1.04}^{\ast }{R}_{1\rho}^{exp}-1.96 $$ . The predicted adiabaticR 1 ρ $$ {R}_{1\rho } $$ andR 2 ρ $$ {R}_{2\rho } $$ from cartilage specimens are consistent with those previously measured, as quantified by:R 1 ρ , 2 ρ cal = 1.10 * R 1 ρ , 2 ρ exp - 0.41 $$ {R}_{1\rho, 2\rho}^{cal}={1.10}^{\ast }{R}_{1\rho, 2\rho}^{exp}-0.41 $$ . CONCLUSION This work has theoretically and experimentally demonstrated that adiabaticR 1 ρ $$ {R}_{1\rho } $$ andR 2 ρ $$ {R}_{2\rho } $$ can be recast into a sum ofR 1 $$ {R}_1 $$ andR 2 $$ {R}_2 $$ , with varying weightings. Therefore, any suggestions that adiabatic rotating frame relaxometry in biological tissues could provide more information than the standardR 1 $$ {R}_1 $$ andR 2 $$ {R}_2 $$ warrant closer scrutiny.
Collapse
Affiliation(s)
- Yuxi Pang
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA
| |
Collapse
|
2
|
Coletti C, Naaktgeboren R, Tourais J, Van De Steeg-Henzen C, Weingärtner S. Generalized inhomogeneity-resilient relaxation along a fictitious field (girRAFF) for improved robustness in rotating frame relaxometry at 3T. Magn Reson Med 2024; 92:2373-2391. [PMID: 39046914 DOI: 10.1002/mrm.30219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 06/07/2024] [Accepted: 06/26/2024] [Indexed: 07/27/2024]
Abstract
PURPOSE To optimize Relaxation along a Fictitious Field (RAFF) pulses for rotating frame relaxometry with improved robustness in the presence ofB 0 $$ {\mathrm{B}}_0 $$ andB 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneities. METHODS The resilience of RAFF pulses againstB 0 $$ {\mathrm{B}}_0 $$ andB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities was studied using Bloch simulations. A parameterized extension of the RAFF formulation was introduced and used to derive a generalized inhomogeneity-resilient RAFF (girRAFF) pulse. RAFF and girRAFF preparation efficiency, defined as the ratio of the longitudinal magnetization before and after the preparation (M z ( T p ) / M 0 $$ {M}_z\left({T}_p\right)/{M}_0 $$ ), were simulated and validated in phantom experiments.T RAFF $$ {T}_{\mathrm{RAFF}} $$ andT girRAFF $$ {T}_{\mathrm{girRAFF}} $$ parametric maps were acquired at 3T in phantom, the calf muscle, and the knee cartilage of healthy subjects. The relaxation time maps were analyzed for resilience against artificially induced field inhomogeneities and assessed in terms of in vivo reproducibility. RESULTS Optimized girRAFF preparations yielded improved preparation efficiency (0.95/0.91 simulations/phantom) with respect to RAFF (0.36/0.67 simulations/phantom).T girRAFF $$ {T}_{\mathrm{girRAFF}} $$ preparations showed in phantom/calf 6.0/4.8 times higher resilience toB 0 $$ {\mathrm{B}}_0 $$ inhomogeneities than RAFF, and a 4.7/5.3 improved resilience toB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. In the knee cartilage,T girRAFF $$ {T}_{\mathrm{girRAFF}} $$ (53± $$ \pm $$ 14 ms) was higher thanT RAFF $$ {T}_{\mathrm{RAFF}} $$ (42± $$ \pm $$ 11 ms). Moreover, girRAFF preparations yielded 7.6/4.9 times improved reproducibility acrossB 0 $$ {\mathrm{B}}_0 $$ /B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneity conditions, 1.9 times better reproducibility across subjects and 1.2 times across slices compared with RAFF. Dixon-based fat suppression led to a further 15-fold improvement in the robustness of girRAFF to inhomogeneities. CONCLUSIONS RAFF pulses display residual sensitivity to off-resonance and pronounced sensitivity toB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. Optimized girRAFF pulses provide increased robustness and may be an appealing alternative for applications where resilience against field inhomogeneities is required.
Collapse
Affiliation(s)
- Chiara Coletti
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Roeland Naaktgeboren
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Joao Tourais
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | | | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
- HollandPTC, Delft, The Netherlands
| |
Collapse
|
3
|
Gut P, Cochet H, Stuber M, Bustin A. Magnetic Resonance Myocardial Imaging in Patients With Implantable Cardiac Devices: Challenges, Techniques, and Clinical Applications. Echocardiography 2024; 41:e70012. [PMID: 39469755 DOI: 10.1111/echo.70012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Accepted: 10/10/2024] [Indexed: 10/30/2024] Open
Abstract
Cardiovascular magnetic resonance imaging (MRI) in patients with cardiac implants, such as pacemakers and defibrillators, has gained importance in recent years with the development of modern cardiac implantable electronic devices. The increasing clinical need to perform MRI examinations in patients with cardiac implants has driven the development of new advanced MRI sequences to mitigate image artifacts associated with cardiac implants. More specifically, advances in imaging techniques, such as wideband late gadolinium enhancement imaging, wideband T1 mapping, and wideband perfusion, have been designed to improve image quality and examinations in patients with cardiac implants, enabling a comprehensive and more reliable diagnosis, which was previously unattainable in these patients. This review article explores recent developments and applications of wideband techniques in the field of cardiovascular MRI, offering insights into their transformative potential. Clinical applications of wideband cardiovascular MRI are highlighted, particularly in assessing myocardial viability, guiding ventricular tachycardia ablation, and characterizing myocardial tissue.
Collapse
Affiliation(s)
- Pauline Gut
- IHU LIRYC, Heart Rhythm Disease Institute, Université de Bordeaux - INSERM U1045, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Hubert Cochet
- IHU LIRYC, Heart Rhythm Disease Institute, Université de Bordeaux - INSERM U1045, Pessac, France
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Pessac, France
| | - Matthias Stuber
- IHU LIRYC, Heart Rhythm Disease Institute, Université de Bordeaux - INSERM U1045, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
| | - Aurélien Bustin
- IHU LIRYC, Heart Rhythm Disease Institute, Université de Bordeaux - INSERM U1045, Pessac, France
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Pessac, France
| |
Collapse
|
4
|
Hesse F, Low J, Cao J, Bulat F, Kreis F, Wright AJ, Brindle KM. Deuterium MRI of serine metabolism in mouse models of glioblastoma. Magn Reson Med 2024; 92:1811-1821. [PMID: 38946234 DOI: 10.1002/mrm.30198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Revised: 05/10/2024] [Accepted: 06/04/2024] [Indexed: 07/02/2024]
Abstract
PURPOSE Serine is a major source of one-carbon units needed for the synthesis of nucleotides and the production of intramitochondrial nicotinamide adenine dinucleotide phosphate (NADPH), and it plays an important role in cancer cell proliferation. The aim of this study was to develop a deuterium (2H) MRS imaging method for imaging tumor serine metabolism. METHODS Sequential (2H) spectra and spectroscopic images were used to monitor the metabolism of [2,3,3-2H3]serine in patient-derived glioblastoma cells in vitro and in tumors obtained by their orthotopic implantation in mouse brain. RESULTS [14,14-2H2] 5,10-methylene-tetrahydrofolate, [2H]glycine, [2H]formate, and labeled water were detected in cell suspensions and water labeling in spectroscopic images of tumors. Studies in cells and tumors with variable mitochondrial content and inhibitor studies in cells demonstrated that most of the labeled serine was metabolized in the mitochondria. Water labeling in the cell suspensions was correlated with formate labeling; therefore, water labeling observed in tumors could be used to provide a surrogate measure of flux in the pathway of one-carbon metabolism in vivo. CONCLUSION The method has the potential to be used clinically to select patients for treatment with inhibitors of one-carbon metabolism and subsequently to detect their early responses to such treatment.
Collapse
Affiliation(s)
- Friederike Hesse
- Cancer Research UK Cambridge Institute, Cambridge, UK
- Department of Radiology, University of Cambridge, Cambridge, UK
| | - Jacob Low
- Cancer Research UK Cambridge Institute, Cambridge, UK
| | - Jianbo Cao
- Cancer Research UK Cambridge Institute, Cambridge, UK
| | - Flaviu Bulat
- Cancer Research UK Cambridge Institute, Cambridge, UK
- Department of Chemistry, University of Cambridge, Cambridge, UK
| | - Felix Kreis
- Cancer Research UK Cambridge Institute, Cambridge, UK
| | - Alan J Wright
- Cancer Research UK Cambridge Institute, Cambridge, UK
| | - Kevin M Brindle
- Cancer Research UK Cambridge Institute, Cambridge, UK
- Department of Biochemistry, University of Cambridge, Cambridge, UK
| |
Collapse
|
5
|
Maguin C, Mougel E, Valette J, Flament J. Toward quantitative CEST imaging of glutamate in the mouse brain using a multi-pool exchange model calibrated by 1H-MRS. Magn Reson Med 2024. [PMID: 39449296 DOI: 10.1002/mrm.30353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 09/09/2024] [Accepted: 10/03/2024] [Indexed: 10/26/2024]
Abstract
PURPOSE To develop a CEST quantification model to map glutamate concentration in the mouse brain at 11.7 T, overcoming the limitations of conventional glutamate-weighted CEST (gluCEST) contrast (magnetization transfer ratio with asymmetric analysis). METHODS 1H-MRS was used as a gold standard for glutamate quantification to calibrate a CEST-based quantitative pipeline. Joint localized measurements of Z-spectra at B1 = 5 μT and quantitative 1H-MRS were carried out in two voxels of interest in the mouse brain. A six-pool Bloch-McConnell model was found appropriate to fit experimental data. Glutamate exchange rate was estimated in both regions with this dedicated multi-pool fitting model and using glutamate concentration determined by 1H-MRS. RESULTS Glutamate exchange rate was estimated to be ˜1300 Hz in the mouse brain. Using this calibrated value, maps of glutamate concentration in the mouse brain were obtained by pixel-by-pixel fitting of Z-spectra at B1 = 5 μT. A complementary study of simulations, however, showed that the quantitative model has high sensitivity to noise, and therefore, requires high-SNR acquisitions. Interestingly, fitted [Glu] seemed to be overestimated compared to 1H-MRS measurements, although it was estimated with simulations that the model has no intrinsic fitting bias with our experimental level of noise. The hypothesis of an unknown proton-exchanging pool contributing to gluCEST signal is discussed. CONCLUSION High-resolution mapping of glutamate in the brain was made possible using the proposed calibrated quantification model of gluCEST data. Further studying of the in vivo molecular contributions to gluCEST signal could improve modeling.
Collapse
Affiliation(s)
- Cécile Maguin
- Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Fontenay-aux-Roses, France
| | - Eloïse Mougel
- Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Fontenay-aux-Roses, France
| | - Julien Valette
- Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Fontenay-aux-Roses, France
| | - Julien Flament
- Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Fontenay-aux-Roses, France
| |
Collapse
|
6
|
Jang A, He X, Liu F. Physics-guided self-supervised learning: Demonstration for generalized RF pulse design. Magn Reson Med 2024. [PMID: 39385438 DOI: 10.1002/mrm.30307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/07/2024] [Accepted: 09/01/2024] [Indexed: 10/12/2024]
Abstract
PURPOSE To introduce a new method for generalized RF pulse design using physics-guided self-supervised learning (GPS), which uses the Bloch equations as the guiding physics model. THEORY AND METHODS The GPS framework consists of a neural network module and a physics module, where the physics module is a Bloch simulator for MRI applications. For RF pulse design, the neural network module maps an input target profile to an RF pulse, which is subsequently loaded into the physics module. Through the supervision of the physics module, the neural network module designs an RF pulse corresponding to the target profile. GPS was applied to design 1D selective,B 1 $$ {B}_1 $$ -insensitive, saturation, and multidimensional RF pulses, each conventionally requiring dedicated design algorithms. We further demonstrate our method's flexibility and versatility by compensating for experimental and scanner imperfections through online adaptation. RESULTS Both simulations and experiments show that GPS can design a variety of RF pulses with corresponding profiles that agree well with the target input. Despite these verifications, GPS-designed pulses have unique differences compared to conventional designs, such as achievingB 1 $$ {B}_1 $$ -insensitivity using different mechanisms and using non-sampled regions of the conventional design to lower its peak power. Experiments, both ex vivo and in vivo, further verify that it can also be used for online adaptation to correct system imperfections, such asB 0 $$ {B}_0 $$ /B 1 + $$ {B}_1^{+} $$ inhomogeneity. CONCLUSION This work demonstrates the generalizability, versatility, and flexibility of the GPS method for designing RF pulses and showcases its utility in several applications.
Collapse
Affiliation(s)
- Albert Jang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Xingxin He
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| | - Fang Liu
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
7
|
Graf C, Stollberger R, Rund A, Schweiger M, Diwoky C. Robust dual-angle T 1 measurement in magnetization transfer spectroscopy by time-optimal control. NMR IN BIOMEDICINE 2024; 37:e5151. [PMID: 38583871 DOI: 10.1002/nbm.5151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/07/2024] [Accepted: 03/01/2024] [Indexed: 04/09/2024]
Abstract
Magnetization transfer spectroscopy relies heavily on the robust determination ofT 1 relaxation times of nuclei participating in metabolic exchange. Challenges arise due to the use of surface RF coils for transmission (highB 1 + variation) and the broad resonance band of most X nuclei. These challenges are particularly pronounced when fastT 1 mapping methods, such as the dual-angle method, are employed. Consequently, in this work, we develop resonance offset andB 1 + robust excitation RF pulses for 31P magnetization transfer spectroscopy at 7T through ensemble-based time-optimal control. In our approach, we introduce a cost functional for designing robust pulses, incorporating the full Bloch equations as constraints, which are solved using symmetric operator splitting techniques. The optimal control design of the RF pulses developed demonstrates improved accuracy, desired phase properties, and reduced RF power when applied to dual-angleT 1 mapping, thereby improving the precision of exchange-rate measurements, as demonstrated in a preclinical in vivo study quantifying brain creatine kinase activity.
Collapse
Affiliation(s)
- Christina Graf
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- Department of Pediatrics, University of British Columbia, Vancouver, BC, Canada
| | - Rudolf Stollberger
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- BioTechMed-Graz, Graz, Austria
| | - Armin Rund
- Institute for Mathematics and Scientific Computing, Karl-Franzens University Graz, Graz, Austria
| | - Martina Schweiger
- BioTechMed-Graz, Graz, Austria
- Institute of Molecular Biosciences, Karl-Franzens University Graz, Graz, Austria
- Field of Excellence BioHealthKarl-Franzens University Graz, Graz, Austria
| | - Clemens Diwoky
- Institute of Molecular Biosciences, Karl-Franzens University Graz, Graz, Austria
| |
Collapse
|
8
|
Kantola V, Karjalainen J, Jaakola T, Leskinen HPP, Nissi MJ, Casula V, Nieminen MT. Anisotropy of T 2 and T 1ρ relaxation time in articular cartilage at 3 T. Magn Reson Med 2024; 92:1177-1188. [PMID: 38558167 DOI: 10.1002/mrm.30096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 03/14/2024] [Accepted: 03/15/2024] [Indexed: 04/04/2024]
Abstract
PURPOSE The anisotropy of R2 and R1ρ relaxation rates in articular cartilage contains information about the collagenous structure of the tissue. Here we determine and study the anisotropic and isotropic components of T2 and T1ρ relaxation parameters in articular cartilage with a clinical 3T MRI device. Furthermore, a visual representation of the topographical variation in anisotropy is given via anisotropy mapping. METHODS Eight bovine stifle joints were imaged at 22 orientations with respect to the main magnetic field using T2, continuous-wave (CW) T1ρ, and adiabatic T1ρ mapping sequences. Relaxation rates were separated into isotropic and anisotropic relaxation components using a previously established relaxation anisotropy model. Pixel-wise anisotropy values were determined from the relaxation-time maps using Michelson contrast. RESULTS The relaxation rates obtained from the samples displayed notable variation depending on the sample orientation, magnetization preparation, and cartilage layer. R2 demonstrated significant anisotropy, whereas CW-R1ρ (300 Hz) and CW-R1ρ (500 Hz) displayed a low degree of anisotropy. Adiabatic R1ρ was largely isotropic. In the deep cartilage regions, relaxation rates were generally faster and more anisotropic than in the cartilage closer to the tissue surface. The isotropic relaxation rate components were found to have similar values regardless of measurement sequence. CONCLUSIONS The fitted relaxation model for T2 and T1ρ demonstrated varying amounts anisotropy, depending on magnetization preparation, and studied the articular cartilage layer. Anisotropy mapping of full joints showed varying amounts of anisotropy depending on the quantitative MRI parameter and topographical location, and in the case of T2, showed systematic changes in anisotropy across cartilage depth.
Collapse
Affiliation(s)
- Ville Kantola
- Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
- Medical Research Center, University of Oulu, Oulu University Hospital, Oulu, Finland
| | - Jouni Karjalainen
- Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
- Medical Research Center, University of Oulu, Oulu University Hospital, Oulu, Finland
| | - Tomi Jaakola
- Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
| | - Henri P P Leskinen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
| | - Mikko J Nissi
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
| | - Victor Casula
- Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
- Medical Research Center, University of Oulu, Oulu University Hospital, Oulu, Finland
| | - Miika T Nieminen
- Research Unit of Health Sciences and Technology, University of Oulu, Oulu, Finland
- Medical Research Center, University of Oulu, Oulu University Hospital, Oulu, Finland
- Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland
| |
Collapse
|
9
|
Shah ND, Krishnam M, Ambale Venkatesh B, Khan F, Smith M, Jones DR, Koon P, Mao X, Janich MA, Brau ACS, Salerno M, Dash R, Chan F, Yang PC. Wideband radiofrequency pulse sequence for evaluation of myocardial scar in patients with cardiac implantable devices. FRONTIERS IN RADIOLOGY 2024; 4:1327406. [PMID: 39175870 PMCID: PMC11339872 DOI: 10.3389/fradi.2024.1327406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 07/17/2024] [Indexed: 08/24/2024]
Abstract
Background Cardiac magnetic resonance is a useful clinical tool to identify late gadolinium enhancement in heart failure patients with implantable electronic devices. Identification of LGE in patients with CIED is limited by artifact, which can be improved with a wide band radiofrequency pulse sequence. Objective The authors hypothesize that image quality of LGE images produced using wide-band pulse sequence in patients with devices is comparable to image quality produced using standard LGE sequences in patients without devices. Methods Two independent readers reviewed LGE images of 16 patients with CIED and 7 patients without intracardiac devices to assess for image quality, device-related artifact, and presence of LGE using the American Society of Echocardiography/American Heart Association 17 segment model of the heart on a 4-point Likert scale. The mean and standard deviation for image quality and artifact rating were determined. Inter-observer reliability was determined by calculating Cohen's kappa coefficient. Statistical significance was determined by T-test as a p {less than or equal to} 0.05 with a 95% confidence interval. Results All patients underwent CMR without any adverse events. Overall IQ of WB LGE images was significantly better in patients with devices compared to standard LGE in patients without devices (p = 0.001) with reduction in overall artifact rating (p = 0.05). Conclusion Our study suggests wide-band pulse sequence for LGE can be applied safely to heart failure patients with devices in detection of LV myocardial scar while maintaining image quality, reducing artifact, and following routine imaging protocol after intravenous gadolinium contrast administration.
Collapse
Affiliation(s)
- Neil D. Shah
- Department of Medicine, Medical College of Wisconsin, Milwaukee, WI, United States
| | - Mayil Krishnam
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Bharat Ambale Venkatesh
- Department of Medicine, Division of Cardiovascular Medicine, Johns Hopkins University, Baltimore, MD, United States
| | - Fouzia Khan
- Department of Medicine, Division of Cardiovascular Medicine, Stanford University, Stanford, CA, United States
| | - Michele Smith
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Darwin R. Jones
- Department of Radiology, Stanford University, Stanford, CA, United States
| | | | | | | | | | - Michael Salerno
- Department of Medicine, Division of Cardiovascular Medicine, Stanford University, Stanford, CA, United States
| | - Rajesh Dash
- Department of Medicine, Division of Cardiovascular Medicine, Stanford University, Stanford, CA, United States
| | - Frandics Chan
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Phillip C. Yang
- Department of Medicine, Division of Cardiovascular Medicine, Stanford University, Stanford, CA, United States
| |
Collapse
|
10
|
Shin SH, Moazamian D, Suprana A, Zeng C, Athertya JS, Carl M, Ma Y, Jang H, Du J. Yet more evidence that non-aqueous myelin lipids can be directly imaged with ultrashort echo time (UTE) MRI on a clinical 3T scanner: a lyophilized red blood cell membrane lipid study. Neuroimage 2024; 296:120666. [PMID: 38830440 PMCID: PMC11380916 DOI: 10.1016/j.neuroimage.2024.120666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 05/16/2024] [Accepted: 05/31/2024] [Indexed: 06/05/2024] Open
Abstract
Direct imaging of semi-solid lipids, such as myelin, is of great interest as a noninvasive biomarker of neurodegenerative diseases. Yet, the short T2 relaxation times of semi-solid lipid protons hamper direct detection through conventional magnetic resonance imaging (MRI) pulse sequences. In this study, we examined whether a three-dimensional ultrashort echo time (3D UTE) sequence can directly acquire signals from membrane lipids. Membrane lipids from red blood cells (RBC) were collected from commercially available blood as a general model of the myelin lipid bilayer and subjected to D2O exchange and freeze-drying for complete water removal. Sufficiently high MR signals were detected with the 3D UTE sequence, which showed an ultrashort T2* of ∼77-271 µs and a short T1 of ∼189 ms for semi-solid RBC membrane lipids. These measurements can guide designing UTE-based sequences for direct in vivo imaging of membrane lipids.
Collapse
Affiliation(s)
- Soo Hyun Shin
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Dina Moazamian
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Arya Suprana
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Shu Chien-Gene Lay Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA
| | - Chun Zeng
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Jiyo S Athertya
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | | | - Yajun Ma
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Shu Chien-Gene Lay Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, La Jolla, CA, USA.
| |
Collapse
|
11
|
Kobayashi N. Optimization of flip angle and radiofrequency pulse phase to maximize steady-state magnetization in three-dimensional missing pulse steady-state free precession. NMR IN BIOMEDICINE 2024; 37:e5112. [PMID: 38299770 PMCID: PMC11078623 DOI: 10.1002/nbm.5112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 12/07/2023] [Accepted: 01/09/2024] [Indexed: 02/02/2024]
Abstract
Missing pulse (MP) steady-state free precession (SSFP) is a magnetic resonance imaging (MRI) pulse sequence that is highly tolerant to the magnetic field inhomogeneity. In this study, optimal flip angle and radiofrequency (RF) phase scheduling in three-dimensional (3D) MP-SSFP is introduced to maximize the steady-state magnetization while keeping broadband excitation to cover widely distributed frequencies generated by inhomogeneous magnetic fields. Numerical optimization based on extended phase graph (EPG) simulation was performed to maximize the MP-SSFP steady-state magnetization. To limit the specific absorption rate (SAR) associated with the broadband excitation in 3D MP-SSFP, SAR constraint was introduced in the numerical optimization. Optimized flip angle and RF phase settings were experimentally tested by introducing a linear inhomogeneous magnetic field in a range of 10-20 mT/m and using a phantom with known T1/T2 relaxation and diffusion parameters at 3 T. The experimental results were validated through comparisons with EPG simulation. Image contrasts and molecular diffusion effects were investigated in in vivo human brain imaging with 3D MP-SSFP with the optimal flip angle and RF phase settings. In the phantom measurements, the optimal flip angle and RF phase settings improved the MP-SSFP steady-state magnetization/signal-to-noise ratio by up to 41% under the fixed SAR conditions, which matched well with EPG simulation results. In vivo brain imaging with the optimal RF pulse settings provided T2-like image contrasts. Diffusion effects were relatively minor with the linear inhomogeneous field of 10-20 mT/m for white and gray matter, but cerebrospinal fluid showed conspicuous signal intensity attenuation as the linear inhomogeneous field increased. Numerical optimization achieved significant improvement in the steady-state magnetization in MP-SSFP compared with the RF pulse settings used in previous studies. The proposed flip angle and RF phase optimization is promising to improve 3D MP-SSFP image quality for MRI in inhomogeneous magnetic fields.
Collapse
Affiliation(s)
- Naoharu Kobayashi
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
12
|
Zhan H, Chen Y, Cui Y, Zeng Y, Feng X, Tan C, Huang C, Lin E, Huang Y, Chen Z. Pure-Shift-Based Proton Magnetic Resonance Spectroscopy for High-Resolution Studies of Biological Samples. Int J Mol Sci 2024; 25:4698. [PMID: 38731917 PMCID: PMC11083948 DOI: 10.3390/ijms25094698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 04/18/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024] Open
Abstract
Proton magnetic resonance spectroscopy (1H MRS) presents a powerful tool for revealing molecular-level metabolite information, complementary to the anatomical insight delivered by magnetic resonance imaging (MRI), thus playing a significant role in in vivo/in vitro biological studies. However, its further applications are generally confined by spectral congestion caused by numerous biological metabolites contained within the limited proton frequency range. Herein, we propose a pure-shift-based 1H localized MRS method as a proof of concept for high-resolution studies of biological samples. Benefitting from the spectral simplification from multiplets to singlet peaks, this method addresses the challenge of spectral congestion encountered in conventional MRS experiments and facilitates metabolite analysis from crowded NMR resonances. The performance of the proposed pure-shift 1H MRS method is demonstrated on different kinds of samples, including brain metabolite phantom and in vitro biological samples of intact pig brain tissue and grape tissue, using a 7.0 T animal MRI scanner. This proposed MRS method is readily implemented in common commercial NMR/MRI instruments because of its generally adopted pulse-sequence modules. Therefore, this study takes a meaningful step for MRS studies toward potential applications in metabolite analysis and disease diagnosis.
Collapse
Affiliation(s)
- Haolin Zhan
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
- Department of Biomedical Engineering, Anhui Provincial Engineering Research Center of Semiconductor Inspection Technology and Instrument, Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, Hefei University of Technology, Hefei 230009, China
| | - Yulei Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Yinping Cui
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Yunsong Zeng
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Xiaozhen Feng
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Chunhua Tan
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Chengda Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Enping Lin
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Yuqing Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen 361005, China
| |
Collapse
|
13
|
Saleh MG, Prescot A, Chang L, Cloak C, Cunningham E, Subramaniam P, Renshaw PF, Yurgelun-Todd D, Zöllner HJ, Roberts TPL, Edden RAE, Ernst T. Glutamate measurements using edited MRS. Magn Reson Med 2024; 91:1314-1322. [PMID: 38044723 PMCID: PMC10865745 DOI: 10.1002/mrm.29929] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/02/2023] [Accepted: 10/31/2023] [Indexed: 12/05/2023]
Abstract
PURPOSE To demonstrate J-difference coediting of glutamate using Hadamard encoding and reconstruction of Mescher-Garwood-edited spectroscopy (HERMES). METHODS Density-matrix simulations of HERMES (TE 80 ms) and 1D J-resolved (TE 31-229 ms) of glutamate (Glu), glutamine (Gln), γ-aminobutyric acid (GABA), and glutathione (GSH) were performed. HERMES comprised four sub-experiments with editing pulses applied as follows: (A) 1.9/4.56 ppm simultaneously (ONGABA /ONGSH ); (B) 1.9 ppm only (ONGABA /OFFGSH ); (C) 4.56 ppm only (OFFGABA /ONGSH ); and (D) 7.5 ppm (OFFGABA /OFFGSH ). Phantom HERMES and 1D J-resolved experiments of Glu were performed. Finally, in vivo HERMES (20-ms editing pulses) and 1D J-resolved (TE 31-229 ms) experiments were performed on 137 participants using 3 T MRI scanners. LCModel was used for quantification. RESULTS HERMES simulation and phantom experiments show a Glu-edited signal at 2.34 ppm in the Hadamard sum combination A+B+C+D with no overlapping Gln signal. The J-resolved simulations and phantom experiments show substantial TE modulation of the Glu and Gln signals across the TEs, whose average yields a well-resolved Glu signal closely matching the Glu-edited signal from the HERMES sum spectrum. In vivo quantification of Glu show that the two methods are highly correlated (p < 0.001) with a bias of ∼10%, along with similar between-subject coefficients of variation (HERMES/TE-averaged: ∼7.3%/∼6.9%). Other Hadamard combinations produce the expected GABA-edited (A+B-C-D) or GSH-edited (A-B+C-D) signal. CONCLUSION HERMES simulation and phantom experiments show the separation of Glu from Gln. In vivo HERMES experiments yield Glu (without Gln), GABA, and GSH in a single MRS scan.
Collapse
Affiliation(s)
- Muhammad G Saleh
- Lurie Family Foundations MEG Imaging Center, Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Andrew Prescot
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, USA
| | - Linda Chang
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Christine Cloak
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Eric Cunningham
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| | - Punitha Subramaniam
- Department of Psychiatry, University of Utah, Salt Lake City, Utah, USA
- Diagnostic Neuroimaging Laboratory, University of Utah, Salt Lake City, Utah, USA
| | - Perry F Renshaw
- Department of Psychiatry, University of Utah, Salt Lake City, Utah, USA
- Diagnostic Neuroimaging Laboratory, University of Utah, Salt Lake City, Utah, USA
| | - Deborah Yurgelun-Todd
- Department of Psychiatry, University of Utah, Salt Lake City, Utah, USA
- Diagnostic Neuroimaging Laboratory, University of Utah, Salt Lake City, Utah, USA
| | - Helge J Zöllner
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Timothy P L Roberts
- Lurie Family Foundations MEG Imaging Center, Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Richard A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Thomas Ernst
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
14
|
Shahid SS, Dzemidzic M, Butch ER, Jarvis EE, Snyder SE, Wu YC. Estimating the synaptic density deficit in Alzheimer's disease using multi-contrast CEST imaging. PLoS One 2024; 19:e0299961. [PMID: 38483851 PMCID: PMC10939256 DOI: 10.1371/journal.pone.0299961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 02/12/2024] [Indexed: 03/17/2024] Open
Abstract
In vivo noninvasive imaging of neurometabolites is crucial to improve our understanding of the underlying pathophysiological mechanism in neurodegenerative diseases. Abnormal changes in synaptic organization leading to synaptic degradation and neuronal loss is considered as one of the primary factors driving Alzheimer's disease pathology. Magnetic resonance based molecular imaging techniques such as chemical exchange saturation transfer (CEST) and magnetic resonance spectroscopy (MRS) can provide neurometabolite specific information which may relate to underlying pathological and compensatory mechanisms. In this study, CEST and short echo time single voxel MRS was performed to evaluate the sensitivity of cerebral metabolites to beta-amyloid (Aβ) induced synaptic deficit in the hippocampus of a mouse model of Alzheimer's disease. The CEST based spectra (Z-spectra) were acquired on a 9.4 Tesla small animal MR imaging system with two radiofrequency (RF) saturation amplitudes (1.47 μT and 5.9 μT) to obtain creatine-weighted and glutamate-weighted CEST contrasts, respectively. Multi-pool Lorentzian fitting and quantitative T1 longitudinal relaxation maps were used to obtain metabolic specific apparent exchange-dependent relaxation (AREX) maps. Short echo time (TE = 12 ms) single voxel MRS was acquired to quantify multiple neurometabolites from the right hippocampus region. AREX contrasts and MRS based metabolite concentration levels were examined in the ARTE10 animal model for Alzheimer's disease and their wild type (WT) littermate counterparts (age = 10 months). Using MRS voxel as a region of interest, group-wise analysis showed significant reduction in Glu-AREX and Cr-AREX in ARTE10, compared to WT animals. The MRS based results in the ARTE10 mice showed significant decrease in glutamate (Glu) and glutamate-total creatine (Glu/tCr) ratio, compared to WT animals. The MRS results also showed significant increase in total creatine (tCr), phosphocreatine (PCr) and glutathione (GSH) concentration levels in ARTE10, compared to WT animals. In the same ROI, Glu-AREX and Cr-AREX demonstrated positive associations with Glu/tCr ratio. These results indicate the involvement of neurotransmitter metabolites and energy metabolism in Aβ-mediated synaptic degradation in the hippocampus region. The study also highlights the feasibility of CEST and MRS to identify and track multiple competing and compensatory mechanisms involved in heterogeneous pathophysiology of Alzheimer's disease in vivo.
Collapse
Affiliation(s)
- Syed Salman Shahid
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, United States of America
| | - Mario Dzemidzic
- Department of Neurology, Indiana University School of Medicine, Indianapolis, IN, United States of America
| | - Elizabeth R. Butch
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, United States of America
| | - Erin E. Jarvis
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, United States of America
- Stark Neurosciences Research Institute, Indiana University School of Medicine, Indianapolis, IN, United States of America
| | - Scott E. Snyder
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, United States of America
| | - Yu-Chien Wu
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN, United States of America
- Stark Neurosciences Research Institute, Indiana University School of Medicine, Indianapolis, IN, United States of America
- Weldon School of Biomedical Engineering at Purdue University, West Lafayette, IN, United States of America
| |
Collapse
|
15
|
Wi S, Li C, Pham K, Lee W, Frydman L. Short and long range 2D 15N- 15N NMR correlations among peptide groups by novel solid state dipolar mixing schemes. JOURNAL OF BIOMOLECULAR NMR 2024; 78:19-30. [PMID: 38102490 DOI: 10.1007/s10858-023-00429-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 11/06/2023] [Indexed: 12/17/2023]
Abstract
A recently developed homonuclear dipolar recoupling scheme, Adiabatic Linearly FREquency Swept reCOupling (AL FRESCO), was applied to record two-dimensional (2D) 15N-15N correlations on uniformly 15N-labeled GB1 powders. A major feature exploited in these 15N-15N correlations was AL FRESCO's remarkably low RF power demands, which enabled seconds-long mixing schemes when establishing direct correlations. These 15N-15N mixing schemes proved efficient regardless of the magic-angle spinning (MAS) rate and, being nearly free from dipolar truncation effects, they enabled the detection of long-range, weak dipolar couplings, even in the presence of strong short-range dipolar couplings. This led to a connectivity information that was significantly better than that obtained with spontaneously proton-driven, 15N spin-diffusion experiments. An indirect approach producing long-range 15N-15N correlations was also tested, relying on short (ms-long) 1HN-1HN mixings schemes while applying AL FRESCO chirped pulses along the 15N channel. These indirect mixing schemes produced numerous long-distance Ni-Ni±n (n = 2 - 5) correlations, that might be useful for characterizing three-dimensional arrangements in proteins. Once again, these AL FRESCO mediated experiments proved more informative than variants based on spin-diffusion-based 1HN-1HN counterparts.
Collapse
Affiliation(s)
- Sungsool Wi
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, 32304, USA.
| | - Conggang Li
- Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan, 430071, People's Republic of China
| | - Karen Pham
- Department of Chemistry, University of Colorado at Denver, Denver, CO, 80217-3364, USA
| | - Woonghee Lee
- Department of Chemistry, University of Colorado at Denver, Denver, CO, 80217-3364, USA
| | - Lucio Frydman
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, 32304, USA.
- Department of Chemical and Biological Physics, Weizmann Institute of Sciences, Rehovot, Israel.
| |
Collapse
|
16
|
Tsai YC, Huang SM, Peng HH, Lin SW, Lin SR, Chin TY, Huang SM. Imbalance of synaptic and extrasynaptic NMDA receptors induced by the deletion of CRMP1 accelerates age-related cognitive decline in mice. Neurobiol Aging 2024; 135:48-59. [PMID: 38176125 DOI: 10.1016/j.neurobiolaging.2023.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 12/25/2023] [Accepted: 12/27/2023] [Indexed: 01/06/2024]
Abstract
Collapsin response mediator protein 1 (CRMP1) is involved in semaphorin 3A signaling pathway, promoting neurite extension and growth cone collapse. It is highly expressed in the nervous system, especially the hippocampus. The crmp1 knockout (KO) mice display impaired spatial learning and memory, and this phenomenon seemingly tends to deteriorate with age. Here we investigated whether CRMP1 is involved in age-related cognitive decline in WT and crmp1 KO mice at adult, middle-aged and older stages. The results revealed that cognitive dysfunction in the Morris water maze task became more severe and decreased glutamate and glutamine level in middle-aged crmp1 KO mice. Additionally, increasing levels of extrasynaptic NMDA receptors and phosphorylation of Tau were observed in middle-aged crmp1 KO mice, leading to synaptic and neuronal loss in the CA3 regions of hippocampus. These findings suggest that deletion of CRMP1 accelerates age-related cognitive decline by disrupting the balance between synaptic and extrasynaptic NMDA receptors, resulting in the loss of synapses and neurons.
Collapse
Affiliation(s)
- Yun-Chieh Tsai
- Graduate Institute of Life Sciences, National Defense Medical Center, Taipei, Taiwan
| | - Sheng-Min Huang
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Miaoli, Taiwan
| | - Hsu-Hsia Peng
- Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan
| | - Shu-Wha Lin
- Department of Clinical Laboratory Sciences and Medical Biotechnology, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shu-Rung Lin
- Department of Bioscience Technology, Chung Yuan Christian University, Taoyuan, Taiwan.
| | - Ting-Yu Chin
- Department of Bioscience Technology, Chung Yuan Christian University, Taoyuan, Taiwan.
| | - Shih-Ming Huang
- Graduate Institute of Life Sciences, National Defense Medical Center, Taipei, Taiwan; Department of Biochemistry, National Defense Medical Center, Taipei, Taiwan.
| |
Collapse
|
17
|
Ligneul C, Najac C, Döring A, Beaulieu C, Branzoli F, Clarke WT, Cudalbu C, Genovese G, Jbabdi S, Jelescu I, Karampinos D, Kreis R, Lundell H, Marjańska M, Möller HE, Mosso J, Mougel E, Posse S, Ruschke S, Simsek K, Szczepankiewicz F, Tal A, Tax C, Oeltzschner G, Palombo M, Ronen I, Valette J. Diffusion-weighted MR spectroscopy: Consensus, recommendations, and resources from acquisition to modeling. Magn Reson Med 2024; 91:860-885. [PMID: 37946584 DOI: 10.1002/mrm.29877] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/18/2023] [Accepted: 09/08/2023] [Indexed: 11/12/2023]
Abstract
Brain cell structure and function reflect neurodevelopment, plasticity, and aging; and changes can help flag pathological processes such as neurodegeneration and neuroinflammation. Accurate and quantitative methods to noninvasively disentangle cellular structural features are needed and are a substantial focus of brain research. Diffusion-weighted MRS (dMRS) gives access to diffusion properties of endogenous intracellular brain metabolites that are preferentially located inside specific brain cell populations. Despite its great potential, dMRS remains a challenging technique on all levels: from the data acquisition to the analysis, quantification, modeling, and interpretation of results. These challenges were the motivation behind the organization of the Lorentz Center workshop on "Best Practices & Tools for Diffusion MR Spectroscopy" held in Leiden, the Netherlands, in September 2021. During the workshop, the dMRS community established a set of recommendations to execute robust dMRS studies. This paper provides a description of the steps needed for acquiring, processing, fitting, and modeling dMRS data, and provides links to useful resources.
Collapse
Affiliation(s)
- Clémence Ligneul
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Chloé Najac
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - André Döring
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
| | - Christian Beaulieu
- Departments of Biomedical Engineering and Radiology, University of Alberta, Alberta, Edmonton, Canada
| | - Francesca Branzoli
- Paris Brain Institute-ICM, Sorbonne University, UMR S 1127, Inserm U 1127, CNRS UMR 7225, Paris, France
| | - William T Clarke
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Cristina Cudalbu
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Guglielmo Genovese
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minnesota, Minneapolis, USA
| | - Saad Jbabdi
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Ileana Jelescu
- Department of Radiology, Lausanne University Hospital, Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| | - Dimitrios Karampinos
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Roland Kreis
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| | - Henrik Lundell
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital-Amager anf Hvidovre, Hvidovre, Denmark
- Department of Health Technology, Technical University of Denmark, Lyngby, Denmark
| | - Małgorzata Marjańska
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minnesota, Minneapolis, USA
| | - Harald E Möller
- NMR Methods & Development Group, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Jessie Mosso
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- LIFMET, EPFL, Lausanne, Switzerland
| | - Eloïse Mougel
- Université Paris-Saclay, CEA, CNRS, MIRCen, Laboratoires des Maladies Neurodégénératives, Fontenay-aux-Roses, France
| | - Stefan Posse
- Department of Neurology, University of New Mexico School of Medicine, New Mexico, Albuquerque, USA
- Department of Physics and Astronomy, University of New Mexico School of Medicine, New Mexico, Albuquerque, USA
| | - Stefan Ruschke
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munich, Germany
| | - Kadir Simsek
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| | | | - Assaf Tal
- Department of Chemical and Biological Physics, The Weizmann Institute of Science, Rehovot, Israel
| | - Chantal Tax
- University Medical Center Utrecht, Utrecht, The Netherlands
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff, United Kingdom
| | - Georg Oeltzschner
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Maryland, Baltimore, USA
- F. M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Maryland, Baltimore, USA
| | - Marco Palombo
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, UK
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK
| | - Itamar Ronen
- Clinical Imaging Sciences Centre, Brighton and Sussex Medical School, Brighton, UK
| | - Julien Valette
- Université Paris-Saclay, CEA, CNRS, MIRCen, Laboratoires des Maladies Neurodégénératives, Fontenay-aux-Roses, France
| |
Collapse
|
18
|
Ma Y, Carl M, Tang Q, Moazamian D, Athertya JS, Jang H, Bukata SV, Chung CB, Chang EY, Du J. Whole knee joint mapping using a phase modulated UTE adiabatic T 1ρ (PM-UTE-AdiabT 1ρ ) sequence. Magn Reson Med 2024; 91:896-910. [PMID: 37755319 PMCID: PMC10843531 DOI: 10.1002/mrm.29871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 08/14/2023] [Accepted: 08/31/2023] [Indexed: 09/28/2023]
Abstract
PURPOSE To develop a 3D phase modulated UTE adiabatic T1ρ (PM-UTE-AdiabT1ρ ) sequence for whole knee joint mapping on a clinical 3 T scanner. METHODS This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, and (6) a 3D UTE Cones sequence for data acquisition. A simple exponential fitting was used for T1ρ quantification. Phantom studies were performed to investigate PM-UTE-AdiabT1ρ 's sensitivity to compositional changes and reproducibility as well as its correlation with continuous wave-T1ρ measurement. The PM-UTE-AdiabT1ρ technique was then applied to five ex vivo and five in vivo normal knees to measure T1ρ values of femoral cartilage, meniscus, posterior cruciate ligament, anterior cruciate ligament, patellar tendon, and muscle. RESULTS The phantom study demonstrated PM-UTE-AdiabT1ρ 's high sensitivity to compositional changes, its high reproducibility, and its strong linear correlation with continuous wave-T1ρ measurement. The ex vivo and in vivo knee studies demonstrated average T1ρ values of 105.6 ± 8.4 and 77.9 ± 3.9 ms for the femoral cartilage, 39.2 ± 5.1 and 30.1 ± 2.2 ms for the meniscus, 51.6 ± 5.3 and 29.2 ± 2.4 ms for the posterior cruciate ligament, 79.0 ± 9.3 and 52.0 ± 3.1 ms for the anterior cruciate ligament, 19.8 ± 4.5 and 17.0 ± 1.8 ms for the patellar tendon, and 91.1 ± 8.8 and 57.6 ± 2.8 ms for the muscle, respectively. CONCLUSION The 3D PM-UTE-AdiabT1ρ sequence allows volumetric T1ρ assessment for both short and long T2 tissues in the knee joint on a clinical 3 T scanner.
Collapse
Affiliation(s)
- Yajun Ma
- Department of Radiology, University of California San Diego, CA, USA
| | | | - Qingbo Tang
- Department of Radiology, University of California San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
| | - Dina Moazamian
- Department of Radiology, University of California San Diego, CA, USA
| | - Jiyo S Athertya
- Department of Radiology, University of California San Diego, CA, USA
| | - Hyungseok Jang
- Department of Radiology, University of California San Diego, CA, USA
| | - Susan V Bukata
- Department of Orthopaedic Surgery, University of California San Diego, CA, USA
| | - Christine B Chung
- Department of Radiology, University of California San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
| | - Eric Y Chang
- Department of Radiology, University of California San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
| | - Jiang Du
- Department of Radiology, University of California San Diego, CA, USA
- Radiology Service, Veterans Affairs San Diego Healthcare System, CA, USA
- Department of Bioengineering, University of California San Diego, CA, USA
| |
Collapse
|
19
|
Wong D, Bellyou M, Li A, Prado MAM, Beauchet O, Annweiler C, Montero-Odasso M, Bartha R. Magnetic resonance spectroscopy in the hippocampus of adult APP/PS1 mice following chronic vitamin D deficiency. Behav Brain Res 2024; 457:114713. [PMID: 37838248 DOI: 10.1016/j.bbr.2023.114713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/28/2023] [Accepted: 10/10/2023] [Indexed: 10/16/2023]
Abstract
Vitamin D (VitD) deficiency can exacerbate AD progression and may cause changes in brain metabolite levels that can be detected by magnetic resonance spectroscopy (MRS). The purpose of this study was to determine whether chronic VitD deficiency in an AD mouse model caused persistent metabolite levels changes in the hippocampus associated with memory performance. Six-month-old APPSwe/PS1ΔE9 (APP/PS1) mice (N = 14 mice/group) were fed either a VitD deficient (VitD-) diet or a control diet. Metabolite level changes in the hippocampus were evaluated by 1H MRS using a 9.4 T MRI. Ventricle volume was assessed by imaging and spatial memory was evaluated using the Barnes maze. All measurements were made at 6, 9, 12, and 15 months of age. At 15 months of age, amyloid plaque load and astrocyte number were evaluated histologically (N = 4 mice/group). Levels of N-acetyl aspartate and creatine were lower in VitD- mice compared to control diet mice at 12 months of age. VitD deficiency did not change ventricle volume. Lactate levels increased over time in VitD- mice and increases from 12 to 15 months were negatively correlated with changes in primary latency to the target hole in the Barns Maze. VitD- mice showed improved spatial memory performance compared to control diet mice. VitD- mice also had more astrocytes in the cortex and hippocampus at 15 months than control diet mice. This study suggests that severe VitD deficiency in APP/PS1 mice may lead to compensatory changes in metabolite and astrocyte levels that contribute to improved performance on spatial memory tasks.
Collapse
Affiliation(s)
- Dickson Wong
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Miranda Bellyou
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Alex Li
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Marco A M Prado
- Department of Anatomy and Cell Biology, Western University, London, ON, Canada; Department of Physiology and Pharmacology, Western University, London, ON, Canada
| | | | - Cédric Annweiler
- Department of Geriatric Medicine and Memory Clinic, Research Center on Autonomy and Longevity, University Hospital, Angers, France
| | - Manuel Montero-Odasso
- Department of Medicine, Division of Geriatric Medicine, Parkwood Hospital, Western University, London, ON, Canada; Department of Epidemiology and Biostatistics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada
| | - Robert Bartha
- Centre for Functional and Metabolic Mapping, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.
| |
Collapse
|
20
|
Jerban S, Jang H, Chang EY, Bukata S, Du J, Chung CB. Bone Biomarkers Based on Magnetic Resonance Imaging. Semin Musculoskelet Radiol 2024; 28:62-77. [PMID: 38330971 DOI: 10.1055/s-0043-1776431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2024]
Abstract
Magnetic resonance imaging (MRI) is increasingly used to evaluate the microstructural and compositional properties of bone. MRI-based biomarkers can characterize all major compartments of bone: organic, water, fat, and mineral components. However, with a short apparent spin-spin relaxation time (T2*), bone is invisible to conventional MRI sequences that use long echo times. To address this shortcoming, ultrashort echo time MRI sequences have been developed to provide direct imaging of bone and establish a set of MRI-based biomarkers sensitive to the structural and compositional changes of bone. This review article describes the MRI-based bone biomarkers representing total water, pore water, bound water, fat fraction, macromolecular fraction in the organic matrix, and surrogates for mineral density. MRI-based morphological bone imaging techniques are also briefly described.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, La Jolla, California
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, La Jolla, California
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
| | - Susan Bukata
- Department of Orthopaedic Surgery, University of California, San Diego, La Jolla, California
| | - Jiang Du
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
- Department of Bioengineering, University of California, San Diego, La Jolla, California
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, La Jolla, California
- Research Service, Veterans Affairs San Diego Healthcare System, San Diego, California
| |
Collapse
|
21
|
Hui SC, Zöllner HJ, Gong T, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS perform similarly at revealing metabolite-age correlations at 3 T. Magn Reson Med 2024; 91:431-442. [PMID: 37876339 PMCID: PMC10942734 DOI: 10.1002/mrm.29895] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 10/03/2023] [Accepted: 10/04/2023] [Indexed: 10/26/2023]
Abstract
PURPOSE To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate at 3 T. METHODS MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale and posterior cingulate cortex (PCC). Acquisition parameters included TR/TE = 2000/30 ms, 96 transients, and 2048 datapoints sampled at 2 kHz. Spectra were analyzed using Osprey. SNR, FWHM linewidth of total creatine, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. RESULTS SNR and linewidth were significantly higher (p < 0.01) for sLASER than PRESS in PCC. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. PRESS-sLASER measurements were significantly correlated (p < 0.05) for most metabolites. Metabolite-age relationships were consistently identified using both methods. Similar coefficients of variation were observed for most metabolites. CONCLUSION The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in centrum semiovale and PCC data acquired at 3 T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in homogeneous brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- Developing Brain Institute, Children’s National Hospital, Washington, DC, USA
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
22
|
Schiavina M, Bracaglia L, Rodella MA, Kümmerle R, Konrat R, Felli IC, Pierattelli R. Optimal 13C NMR investigation of intrinsically disordered proteins at 1.2 GHz. Nat Protoc 2024; 19:406-440. [PMID: 38087081 DOI: 10.1038/s41596-023-00921-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 09/20/2023] [Indexed: 02/12/2024]
Abstract
Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique for characterizing biomolecules such as proteins and nucleic acids at atomic resolution. Increased magnetic field strengths drive progress in biomolecular NMR applications, leading to improved performance, e.g., higher resolution. A new class of NMR spectrometers with a 28.2 T magnetic field (1.2 GHz 1H frequency) has been commercially available since the end of 2019. The availability of ultra-high-field NMR instrumentation makes it possible to investigate more complex systems using NMR. This is especially true for highly flexible intrinsically disordered proteins (IDPs) and highly flexible regions (IDRs) of complex multidomain proteins. Indeed, the investigation of these proteins is frequently hampered by the crowding of NMR spectra. The advantages, however, are accompanied by challenges that the user must overcome when conducting experiments at such a high field (e.g., large spectral widths, radio frequency bandwidth, performance of decoupling schemes). This protocol presents strategies and tricks for optimising high-field NMR experiments for IDPs/IDRs based on the analysis of the relaxation properties of the investigated protein. The protocol, tested on three IDPs of different molecular weight and structural complexity, focuses on 13C-detected NMR at 1.2 GHz. A set of experiments, including some multiple receiver experiments, and tips to implement versions tailored for IDPs/IDRs are described. However, the general approach and most considerations can also be applied to experiments that acquire 1H or 15N nuclei and to experiments performed at lower field strengths.
Collapse
Affiliation(s)
- Marco Schiavina
- Department of Chemistry 'Ugo Schiff' and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy.
| | - Lorenzo Bracaglia
- Department of Chemistry 'Ugo Schiff' and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy
| | - Maria Anna Rodella
- Department of Chemistry 'Ugo Schiff' and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy
| | | | - Robert Konrat
- Department of Computational and Structural Biology, Max Perutz Labs, University of Vienna, Vienna, Austria
| | - Isabella C Felli
- Department of Chemistry 'Ugo Schiff' and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy.
| | - Roberta Pierattelli
- Department of Chemistry 'Ugo Schiff' and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy.
| |
Collapse
|
23
|
Panariti D, Conron SM, Zhang J, Wasielewski MR, Di Valentin M, Tait CE. Control of excitation selectivity in pulse EPR on spin-correlated radical pairs with shaped pulses. Phys Chem Chem Phys 2024; 26:3842-3856. [PMID: 38221856 DOI: 10.1039/d3cp06009h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
Spin-correlated radical pairs generated by photoinduced electron transfer are characterised by a distinctive spin polarisation and a unique behaviour in pulse electron paramagnetic resonance (EPR) spectroscopy. Under non-selective excitation, an out-of-phase echo signal modulated by the dipolar and exchange coupling interactions characterising the radical pair is observed and allows extraction of geometric information in the two-pulse out-of-phase electron spin echo envelope modulation (ESEEM) experiment. The investigation of the role of spin-correlated radical pairs in a variety of biological processes and in the fundamental mechanisms underlying device function in optoelectronics, as well as their potential use in quantum information science, relies on the ability to precisely address and manipulate the spins using microwave pulses. Here, we explore the use of shaped pulses for controlled narrowband selective and broadband non-selective excitation of spin-correlated radical pairs in two model donor-bridge-acceptor triads, characterised by different spectral widths, at X- and Q-band frequencies. We demonstrate selective excitation with close to rectangular excitation profiles using BURP (band-selective, uniform response, pure-phase) pulses and complete non-selective excitation of both spins of the radical pair using frequency-swept chirp pulses. The use of frequency-swept pulses in out-of-phase ESEEM experiments enables increased modulation depths and, combined with echo transient detection and Fourier transformation, correlation of the dipolar frequencies with the EPR spectrum and therefore the potential to extract additional information on the donor-acceptor pair geometry.
Collapse
Affiliation(s)
- Daniele Panariti
- Department of Chemical Sciences, University of Padova, 35131 Padova, Italy
| | - Sarah M Conron
- Department of Chemistry, Applied Physics Program, and Center for Molecular Quantum Transduction, Northwestern University, Evanston, Illinois 60208-3113, USA
| | - Jinyuan Zhang
- Department of Chemistry, Applied Physics Program, and Center for Molecular Quantum Transduction, Northwestern University, Evanston, Illinois 60208-3113, USA
| | - Michael R Wasielewski
- Department of Chemistry, Applied Physics Program, and Center for Molecular Quantum Transduction, Northwestern University, Evanston, Illinois 60208-3113, USA
| | | | - Claudia E Tait
- Department of Chemistry, University of Oxford, Oxford OX1 3QZ, UK.
| |
Collapse
|
24
|
Wu L, Carchi C, Michaeli S, Mangia S, Idiyatullin D. Alternating Look-Locker for quantitative T 1 , T 1ρ and B 1 3D MRI mapping. Magn Reson Med 2024; 91:149-161. [PMID: 37582198 PMCID: PMC10651079 DOI: 10.1002/mrm.29839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 08/01/2023] [Accepted: 08/02/2023] [Indexed: 08/17/2023]
Abstract
PURPOSE To develop a new MRI method, entitled alternating Look-Locker (aLL), for quantitativeT 1 $$ {T}_1 $$ ,T 1 ρ $$ {T}_{1\uprho} $$ , andB 1 $$ {B}_1 $$ 3D mapping. METHODS A Look-Locker scheme that alternates magnetization from +Z and -Z axes of the laboratory frame is utilized in combination with a 3D Multi-Band Sweep Imaging with Fourier Transformation (MB-SWIFT) readout. The analytical solution describing the spin evolution during aLL, as well as the correction required for segmented acquisition were derived. The simultaneousB 1 $$ {B}_1 $$ andT 1 $$ {T}_1 $$ mapping are demonstrated on an agar/saline phantom and on an in-vivo rat head.T 1 ρ $$ {T}_{1\uprho} $$ relaxation was achieved by cyclically applying magnetization preparation (MP) modules consisting of two adiabatic pulses.T 1 ρ $$ {T}_{1\uprho} $$ values in the rat brain in-vivo and in a gadobenate dimeglumine (Gd-DTPA) phantom were compared to those obtained with a previously introduced steady-state (SS) method. RESULTS The accuracy and precision of the analytical solution was tested by Bloch simulations. With the application of MP modules, the aLL method provides simultaneousT 1 $$ {T}_1 $$ andT 1 ρ $$ {T}_{1\uprho} $$ maps. Conversely, without it, the method can be used for simultaneousT 1 $$ {T}_1 $$ andB 1 $$ {B}_1 $$ mapping.T 1 ρ $$ {T}_{1\uprho} $$ values were similar with both aLL and SS techniques. However, the aLL method resulted in more robust quantitative mapping compared to the SS method. Unlike the SS method, the aLL method does not require additional scans for generatingT 1 $$ {T}_1 $$ maps. CONCLUSION The proposed method offers a new flexible tool for quantitative mapping ofT 1 $$ {T}_1 $$ ,T 1 ρ $$ {T}_{1\uprho} $$ , andB 1 $$ {B}_1 $$ . The aLL method can also be used with readout schemes different from MB-SWIFT.
Collapse
Affiliation(s)
- Lin Wu
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Chris Carchi
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Shalom Michaeli
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Silvia Mangia
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Djaudat Idiyatullin
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA
| |
Collapse
|
25
|
Mosso J, Simicic D, Lanz B, Gruetter R, Cudalbu C. Diffusion-weighted SPECIAL improves the detection of J-coupled metabolites at ultrahigh magnetic field. Magn Reson Med 2024; 91:4-18. [PMID: 37771277 DOI: 10.1002/mrm.29805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 06/16/2023] [Accepted: 07/04/2023] [Indexed: 09/30/2023]
Abstract
PURPOSE To improve the detection and subsequent estimation of the diffusion properties of strongly J-coupled metabolites in diffusion-weighted MRS (DWS). METHODS A new sequence for single-voxel diffusion-weighted 1 H MR spectroscopy, named DW-SPECIAL, is proposed. It combines the semi-adiabatic SPECIAL sequence with a stimulated echo diffusion block. Acquisitions with DW-SPECIAL and STE-LASER, the current gold standard for rodent DWS experiments at high fields, were performed at 14.1T on phantoms and in vivo on the rat brain. The apparent diffusion coefficient and intra-stick diffusivity (Callaghan's model, randomly-oriented sticks) were fitted and compared between the sequences for glutamate, glutamine, myo-inositol, taurine, total NAA, total Cho, total Cr, and the macromolecules. RESULTS The shorter TE achieved with DW-SPECIAL (18 ms against 33 ms with STE-LASER) substantially limited the metabolites' signal loss caused by J-evolution. In addition, DW-SPECIAL preserved the main advantages of STE-LASER: absence of cross-terms, diffusion time during a stimulated echo, and limited sensitivity to B1 inhomogeneities. In vivo, compared to STE-LASER, DW-SPECIAL yielded the same spectral quality and reduced the Cramer Rao Lower Bounds for J-coupled metabolites, irrespective of the b-value. DW-SPECIAL also reduced the SD of the metabolites' diffusion estimates based on individual animal fitting without loss of accuracy compared to the fit on the averaged decay. CONCLUSION We conclude that due to its reduced TE, DW-SPECIAL can serve as an alternative to STE-LASER when strongly J-coupled metabolites like glutamine are investigated, thereby extending the range of accessible metabolites in the context of DWS acquisitions.
Collapse
Affiliation(s)
- Jessie Mosso
- LIFMET, EPFL, Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, EPFL, Lausanne, Switzerland
| | - Dunja Simicic
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, EPFL, Lausanne, Switzerland
| | - Bernard Lanz
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, EPFL, Lausanne, Switzerland
| | | | - Cristina Cudalbu
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, EPFL, Lausanne, Switzerland
| |
Collapse
|
26
|
Kimball JJ, Altenhof AR, Jaroszewicz MJ, Schurko RW. Broadband Cross-Polarization to Half-Integer Quadrupolar Nuclei: Wideline Static NMR Spectroscopy. J Phys Chem A 2023; 127:9621-9634. [PMID: 37922436 DOI: 10.1021/acs.jpca.3c05447] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2023]
Abstract
Cross-polarization (CP) is a technique commonly used for the signal enhancement of NMR spectra; however, applications to quadrupolar nuclei have heretofore been limited due to a number of problems, including poor spin-locking efficiency, inconvenient relaxation times, and reduced CP efficiencies over broad spectral bandwidths─this is unfortunate, since they constitute 73% of NMR-active nuclei in the periodic table. The Broadband Adiabatic Inversion CP (BRAIN-CP) pulse sequence has proven useful for the signal enhancement of wideline and ultra-wideline (i.e., 250 kHz to several MHz in breadth) powder patterns arising from stationary samples; however, a comprehensive investigation of its application to half-integer quadrupolar nuclei (HIQN) is currently lacking. Herein, we present theoretical and experimental considerations for applying BRAIN-CP to acquire central-transition (CT, +1/2 ↔ -1/2) powder patterns of HIQN. Consideration is given to parameters crucial to the success of the experiment, such as the Hartmann-Hahn (HH) matching conditions and the phase modulation of the contact pulse. Modifications to the BRAIN-CP sequence such as flip-back (FB) pulses and ramped contact pulses applied to the 1H spins are used for the reduction of experimental times and increased CP bandwidth capabilities, respectively. Spectra for a series of quadrupolar nuclei with broad CT powder patterns, including 35Cl (S = 3/2), 55Mn (S = 5/2), 59Co (S = 7/2), and 93Nb (S = 9/2), are acquired via direct excitation (CPMG and WCPMG) and indirect excitation (CP/CPMG and BRAIN-CP) methods. We demonstrate that proper implementation of the sequence can enable 1H-S broadband CP over a bandwidth of 1 MHz, which to the best of our knowledge is the largest CP bandwidth reported to date. Finally, we establish the basic principles necessary for simplified optimization and execution of the BRAIN-CP pulse sequence for a wide range of HIQNs.
Collapse
Affiliation(s)
- James J Kimball
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
- National High Magnetic Field Laboratory, Tallahassee, Florida 32310, United States
| | - Adam R Altenhof
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
- National High Magnetic Field Laboratory, Tallahassee, Florida 32310, United States
| | - Michael J Jaroszewicz
- Department of Chemical & Biological Physics, Weizmann Institute of Science, Rehovot 7610001, Israel
| | - Robert W Schurko
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
- National High Magnetic Field Laboratory, Tallahassee, Florida 32310, United States
| |
Collapse
|
27
|
Tkáč I, Xie T, Shah N, Larson S, Dubinsky JM, Gomez-Pastor R, McLoughlin HS, Orr HT, Eberly LE, Öz G. Regional sex differences in neurochemical profiles of healthy mice measured by magnetic resonance spectroscopy at 9.4 tesla. Front Neurosci 2023; 17:1278828. [PMID: 37954878 PMCID: PMC10634209 DOI: 10.3389/fnins.2023.1278828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 10/03/2023] [Indexed: 11/14/2023] Open
Abstract
Objective To determine sex differences in the neurochemical concentrations measured by in vivo proton magnetic resonance spectroscopy (1H MRS) of healthy mice on a genetic background commonly used for neurodegenerative disease models. Methods 1H MRS data collected from wild type mice with C57BL/6 or related genetic backgrounds in seven prior studies were used in this retrospective analysis. To be included, data had to be collected at 9.4 tesla magnetic field using advanced 1H MRS protocols, with isoflurane anesthesia and similar animal handling protocols, and a similar number of datasets from male and female mice had to be available for the brain regions analyzed. Overall, 155 spectra from female mice and 166 spectra from male mice (321 in total), collected from six brain regions (brainstem, cerebellum, cortex, hippocampus, hypothalamus, and striatum) at various ages were included. Results Concentrations of taurine, total creatine (creatine + phosphocreatine), ascorbate, glucose and glutamate were consistently higher in male vs. female mice in most brain regions. Striatum was an exception with similar total creatine in male and female mice. The sex difference pattern in the hypothalamus was notably different from other regions. Interaction between sex and age was significant for total creatine and taurine in the cerebellum and hippocampus. Conclusion Sex differences in regional neurochemical levels are small but significant and age-dependent, with consistent male-female differences across most brain regions. The neuroendocrine region hypothalamus displays a different pattern of sex differences in neurochemical levels. Differences in energy metabolism and cellular density may underlie the differences, with higher metabolic rates in females and higher osmoregulatory and antioxidant capacity in males.
Collapse
Affiliation(s)
- Ivan Tkáč
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States
| | - Tiankai Xie
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, MN, United States
| | - Nitya Shah
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, MN, United States
| | - Sarah Larson
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States
| | - Janet M. Dubinsky
- Department of Neuroscience, University of Minnesota, Minneapolis, MN, United States
| | - Rocio Gomez-Pastor
- Department of Neuroscience, University of Minnesota, Minneapolis, MN, United States
| | | | - Harry T. Orr
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, United States
| | - Lynn E. Eberly
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, MN, United States
| | - Gülin Öz
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|
28
|
Coletti C, Fotaki A, Tourais J, Zhao Y, van de Steeg-Henzen C, Akçakaya M, Tao Q, Prieto C, Weingärtner S. Robust cardiac T 1 ρ $$ {\mathrm{T}}_{1_{\boldsymbol{\rho}}} $$ mapping at 3T using adiabatic spin-lock preparations. Magn Reson Med 2023; 90:1363-1379. [PMID: 37246420 PMCID: PMC10984724 DOI: 10.1002/mrm.29713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 04/26/2023] [Accepted: 05/04/2023] [Indexed: 05/30/2023]
Abstract
PURPOSE The aim of this study is to develop and optimize an adiabaticT 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ (T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ ) mapping method for robust quantification of spin-lock (SL) relaxation in the myocardium at 3T. METHODS Adiabatic SL (aSL) preparations were optimized for resilience againstB 0 $$ {\mathrm{B}}_0 $$ andB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities using Bloch simulations. OptimizedB 0 $$ {\mathrm{B}}_0 $$ -aSL, Bal-aSL andB 1 $$ {\mathrm{B}}_1 $$ -aSL modules, each compensating for different inhomogeneities, were first validated in phantom and human calf. MyocardialT 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ mapping was performed using a single breath-hold cardiac-triggered bSSFP-based sequence. Then, optimizedT 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ preparations were compared to each other and to conventional SL-preparedT 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ maps (RefSL) in phantoms to assess repeatability, and in 13 healthy subjects to investigate image quality, precision, reproducibility and intersubject variability. Finally, aSL and RefSL sequences were tested on six patients with known or suspected cardiovascular disease and compared with LGE,T 1 $$ {\mathrm{T}}_1 $$ , and ECV mapping. RESULTS The highestT 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ preparation efficiency was obtained in simulations for modules comprising 2 HS pulses of 30 ms each. In vivoT 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ maps yielded significantly higher quality than RefSL maps. Average myocardialT 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ values were 183.28± $$ \pm $$ 25.53 ms, compared with 38.21± $$ \pm $$ 14.37 ms RefSL-preparedT 1 ρ $$ {\mathrm{T}}_{1\uprho} $$ .T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ maps showed a significant improvement in precision (avg. 14.47± $$ \pm $$ 3.71% aSL, 37.61± $$ \pm $$ 19.42% RefSL, p < 0.01) and reproducibility (avg. 4.64± $$ \pm $$ 2.18% aSL, 47.39± $$ \pm $$ 12.06% RefSL, p < 0.0001), with decreased inter-subject variability (avg. 8.76± $$ \pm $$ 3.65% aSL, 51.90± $$ \pm $$ 15.27% RefSL, p < 0.0001). Among aSL preparations,B 0 $$ {\mathrm{B}}_0 $$ -aSL achieved the better inter-subject variability. In patients,B 1 $$ {\mathrm{B}}_1 $$ -aSL preparations showed the best artifact resilience among the adiabatic preparations.T 1 ρ , adiab $$ {\mathrm{T}}_{1\uprho, \mathrm{adiab}} $$ times show focal alteration colocalized with areas of hyper-enhancement in the LGE images. CONCLUSION Adiabatic preparations enable robust in vivo quantification of myocardial SL relaxation times at 3T.
Collapse
Affiliation(s)
- Chiara Coletti
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Anastasia Fotaki
- Department of Biomedical Engineering, King’s College London, London, United Kingdom
| | - Joao Tourais
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Yidong Zhao
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | | | - Mehmet Akçakaya
- Department of Electrical and Computer Engineering and Center for Magnetic Resonance Research, University of Minnesota, Minnesota, USA
| | - Qian Tao
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| | - Claudia Prieto
- Department of Biomedical Engineering, King’s College London, London, United Kingdom
- School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
- Milleniun Institute for Intelligent Healthcare Engineering, Santiago, Chile
| | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
29
|
McLoughlin HS, Gundry K, Rainwater O, Schuster KH, Wellik IG, Zalon AJ, Benneyworth MA, Eberly LE, Öz G. Antisense Oligonucleotide Silencing Reverses Abnormal Neurochemistry in Spinocerebellar Ataxia 3 Mice. Ann Neurol 2023; 94:658-671. [PMID: 37243335 PMCID: PMC10543567 DOI: 10.1002/ana.26713] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 05/10/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023]
Abstract
OBJECTIVE Spinocerebellar ataxia type 3 (SCA3) is the most common dominantly inherited ataxia, and biomarkers are needed to noninvasively monitor disease progression and treatment response. Anti-ATXN3 antisense oligonucleotide (ASO) treatment has been shown to mitigate neuropathology and rescue motor phenotypes in SCA3 mice. Here, we investigated whether repeated ASO administration reverses brainstem and cerebellar neurochemical abnormalities by magnetic resonance spectroscopy (MRS). METHODS Symptomatic SCA3 mice received intracerebroventricular treatment of ASO or vehicle and were compared to wild-type vehicle-treated littermates. To quantify neurochemical changes in treated mice, longitudinal 9.4T MRS of cerebellum and brainstem was performed. Acquired magnetic resonance (MR) group means were analyzed by 2-way analysis of variance mixed-effects sex-adjusted analysis with post hoc Sidak correlation for multiple comparisons. Pearson correlations were used to relate SCA3 pathology and behavior. RESULTS MR spectra yielded 15 to 16 neurochemical concentrations in the cerebellum and brainstem. ASO treatment in SCA3 mice resulted in significant total choline rescue and partial reversals of taurine, glutamine, and total N-acetylaspartate across both regions. Some ASO-rescued neurochemicals correlated with reduction in diseased protein and nuclear ATXN3 accumulation. ASO-corrected motor activity correlated with total choline and total N-acetylaspartate levels early in disease. INTERPRETATION SCA3 mouse cerebellar and brainstem neurochemical trends parallel those in patients with SCA3. Decreased total choline may reflect oligodendrocyte abnormalities, decreased total N-acetylaspartate highlights neuronal health disturbances, and high glutamine may indicate gliosis. ASO treatment fully or partially reversed select neurochemical abnormalities in SCA3 mice, indicating the potential for these measures to serve as noninvasive treatment biomarkers in future SCA3 gene silencing trials. ANN NEUROL 2023;94:658-671.
Collapse
Affiliation(s)
| | - Katherine Gundry
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, USA
| | - Orion Rainwater
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, USA
| | | | - Isabel G. Wellik
- Department of Neurology, University of Michigan, Ann Arbor, MI, USA
| | - Annie J. Zalon
- Department of Neurology, University of Michigan, Ann Arbor, MI, USA
| | | | - Lynn E. Eberly
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, USA
- Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, MN, USA
| | - Gülin Öz
- Center for Magnetic Resonance Research, Department of Radiology, Medical School, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
30
|
Hesse F, Wright A, Bulat F, Kreis F, Brindle KM. Assessment of the sensitivity of 2 H MR spectroscopy measurements of [2,3- 2 H 2 ]fumarate metabolism for detecting tumor cell death. NMR IN BIOMEDICINE 2023; 36:e4965. [PMID: 37148156 PMCID: PMC10909471 DOI: 10.1002/nbm.4965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/28/2023] [Accepted: 05/02/2023] [Indexed: 05/07/2023]
Abstract
Imaging the metabolism of [2,3-2 H2 ]fumarate to produce malate can be used to detect tumor cell death post-treatment. Here, we assess the sensitivity of the technique for detecting cell death by lowering the concentration of injected [2,3-2 H2 ]fumarate and by varying the extent of tumor cell death through changes in drug concentration. Mice were implanted subcutaneously with human triple negative breast cancer cells (MDA-MB-231) and injected with 0.1, 0.3, and 0.5 g/kg [2,3-2 H2 ]fumarate before and after treatment with a multivalent TRAlL-R2 agonist (MEDI3039) at 0.1, 0.4, and 0.8 mg/kg. Tumor conversion of [2,3-2 H2 ]fumarate to [2,3-2 H2 ]malate was assessed from a series of 13 spatially localized 2 H MR spectra acquired over 65 min using a pulse-acquire sequence with a 2-ms BIR4 adiabatic excitation pulse. Tumors were then excised and stained for histopathological markers of cell death: cleaved caspase 3 (CC3) and DNA damage (terminal deoxynucleotidyl transferase dUTP nick end labeling [TUNEL]). The rate of malate production and the malate/fumarate ratio plateaued at tumor fumarate concentrations of 2 mM, which were obtained with injected [2,3-2 H2 ]fumarate concentrations of 0.3 g/kg and above. Tumor malate concentration and the malate/fumarate ratio increased linearly with the extent of cell death determined histologically. At an injected [2,3-2 H2 ]fumarate concentration of 0.3 g/kg, 20% CC3 staining corresponded to a malate concentration of 0.62 mM and a malate/fumarate ratio of 0.21. Extrapolation indicated that there would be no detectable malate at 0% CC3 staining. The use of low and nontoxic fumarate concentrations and the production of [2,3-2 H2 ]malate at concentrations that are within the range that can be detected clinically suggest this technique could translate to the clinic.
Collapse
Affiliation(s)
- Friederike Hesse
- Cancer Research UK Cambridge InstituteCambridgeUK
- Department of RadiologyUniversity of CambridgeCambridgeUK
| | - Alan Wright
- Guy's and St Thomas's NHS Foundation TrustSt Thomas' HospitalLondonUK
| | - Flaviu Bulat
- Cancer Research UK Cambridge InstituteCambridgeUK
- Department of ChemistryUniversity of CambridgeCambridgeUK
| | - Felix Kreis
- Cancer Research UK Cambridge InstituteCambridgeUK
| | - Kevin M. Brindle
- Cancer Research UK Cambridge InstituteCambridgeUK
- Department of BiochemistryUniversity of CambridgeCambridgeUK
| |
Collapse
|
31
|
Boucher MC, Sun P, Keresztes I, Harrell LE, Marohn JA. The Landau-Zener-Stückelberg-Majorana transition in the T 2 ≪ T 1 limit. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 354:107523. [PMID: 37625202 PMCID: PMC11382182 DOI: 10.1016/j.jmr.2023.107523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/08/2023] [Accepted: 07/09/2023] [Indexed: 08/27/2023]
Abstract
Landau-Zener-Stückelberg-Majorana (LZSM) transitions occur between quantum states when parameters in the system's Hamiltonian are varied continuously and rapidly. In magnetic resonance, losses in adiabatic rapid passage can be understood using the physics of LZSM transitions. Most treatments of LZSM transitions ignore the T2 dephasing of coherences, however. Motivated by ongoing work in magnetic resonance force microscopy, we employ the Bloch equations, coordinate transformation, and the Magnus expansion to derive expressions for the final magnetization following a rapid field sweep at fixed irradiation intensity that include T2 losses. Our derivation introduces an inversion-function, Fourier transform method for numerically evaluating highly oscillatory integrals. Expressions for the final magnetization are given for low and high irradiation intensity, valid in the T2≪T1 limit. Analytical results are compared to numerical simulations and nuclear magnetic resonance experiments. Our relatively straightforward calculation reproduces semiquantitatively the well known LZSM result in the T2→0 limit.
Collapse
Affiliation(s)
- Michael C Boucher
- Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA
| | - Peter Sun
- Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA
| | - Ivan Keresztes
- Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA
| | - Lee E Harrell
- Department of Physics and Nuclear Engineering, U.S. Military Academy, West Point, NY 10996, USA
| | - John A Marohn
- Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA.
| |
Collapse
|
32
|
Gudmundson AT, Davies-Jenkins CW, Özdemir İ, Murali-Manohar S, Zöllner HJ, Song Y, Hupfeld KE, Schnitzler A, Oeltzschner G, Stark CEL, Edden RAE. Application of a 1H Brain MRS Benchmark Dataset to Deep Learning for Out-of-Voxel Artifacts. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.08.539813. [PMID: 37215030 PMCID: PMC10197548 DOI: 10.1101/2023.05.08.539813] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Neural networks are potentially valuable for many of the challenges associated with MRS data. The purpose of this manuscript is to describe the AGNOSTIC dataset, which contains 259,200 synthetic 1H MRS examples for training and testing neural networks. AGNOSTIC was created using 270 basis sets that were simulated across 18 field strengths and 15 echo times. The synthetic examples were produced to resemble in vivo brain data with combinations of metabolite, macromolecule, residual water signals, and noise. To demonstrate the utility, we apply AGNOSTIC to train two Convolutional Neural Networks (CNNs) to address out-of-voxel (OOV) echoes. A Detection Network was trained to identify the point-wise presence of OOV echoes, providing proof of concept for real-time detection. A Prediction Network was trained to reconstruct OOV echoes, allowing subtraction during post-processing. Complex OOV signals were mixed into 85% of synthetic examples to train two separate CNNs for the detection and prediction of OOV signals. AGNOSTIC is available through Dryad and all Python 3 code is available through GitHub. The Detection network was shown to perform well, identifying 95% of OOV echoes. Traditional modeling of these detected OOV signals was evaluated and may prove to be an effective method during linear-combination modeling. The Prediction Network greatly reduces OOV echoes within FIDs and achieved a median log10 normed-MSE of -1.79, an improvement of almost two orders of magnitude.
Collapse
Affiliation(s)
- Aaron T Gudmundson
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Christopher W Davies-Jenkins
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - İpek Özdemir
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Saipavitra Murali-Manohar
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Helge J Zöllner
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Yulu Song
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Kathleen E Hupfeld
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Alfons Schnitzler
- Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - Georg Oeltzschner
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| | - Craig E L Stark
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA
| | - Richard A E Edden
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins School of Medicine
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute
| |
Collapse
|
33
|
Soher BJ, Semanchuk P, Todd D, Ji X, Deelchand D, Joers J, Oz G, Young K. Vespa: Integrated applications for RF pulse design, spectral simulation and MRS data analysis. Magn Reson Med 2023; 90:823-838. [PMID: 37183778 PMCID: PMC10330446 DOI: 10.1002/mrm.29686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 03/24/2023] [Accepted: 04/12/2023] [Indexed: 05/16/2023]
Abstract
PURPOSE The Vespa package (Versatile Simulation, Pulses, and Analysis) is described and demonstrated. It provides workflows for developing and optimizing linear combination modeling (LCM) fitting for 1 H MRS data using intuitive graphical user interface interfaces for RF pulse design, spectral simulation, and MRS data analysis. Command line interfaces for embedding workflows in MR manufacturer platforms and utilities for synthetic dataset creation are included. Complete provenance is maintained for all steps in workflows. THEORY AND METHODS Vespa is written in Python for compatibility across operating systems. It embeds the PyGAMMA spectral simulation library for spectral simulation. Multiprocessing methods accelerate processing and visualization. Applications use the Vespa database for results storage and cross-application access. Three projects demonstrate pulse, sequence, simulation, and data analysis workflows: (1) short TE semi-LASER single-voxel spectroscopy (SVS) LCM fitting, (2) optimizing MEGA-PRESS (MEscher-GArwood Point RESolved Spectroscopy) flip angle and LCM fitting, and (3) creating a synthetic short TE dataset. RESULTS The LCM workflows for in vivo basis set creation and spectral analysis showed reasonable results for both the short TE semi-LASER and MEGA-PRESS. Examples of pulses, simulations, and data fitting are shown in Vespa application interfaces for various steps to demonstrate the interactive workflow. CONCLUSION Vespa provides an efficient and extensible platform for characterizing RF pulses, pulse design, spectral simulation optimization, and automated LCM fitting via an interactive platform. Modular design and command line interface make it easy to embed in other platforms. As open source, it is free to the MRS community for use and extension. Vespa source code and documentation are available through GitHub.
Collapse
Affiliation(s)
- Brian J. Soher
- Center for Advanced MR Development, Department of Radiology, Duke University Medical Center, Durham, NC, USA
| | - Philip Semanchuk
- Center for Advanced MR Development, Department of Radiology, Duke University Medical Center, Durham, NC, USA
| | | | - Xiao Ji
- Center for Advanced MR Development, Department of Radiology, Duke University Medical Center, Durham, NC, USA
| | - Dinesh Deelchand
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| | - James Joers
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| | - Gulin Oz
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota Medical School, Minneapolis, MN, USA
| | - Karl Young
- Department of Radiology, University of California, San Francisco, CA
| |
Collapse
|
34
|
Endeward B, Bretschneider M, Trenkler P, Prisner TF. Implementation and applications of shaped pulses in EPR. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2023; 136-137:61-82. [PMID: 37716755 DOI: 10.1016/j.pnmrs.2023.04.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 04/12/2023] [Accepted: 04/26/2023] [Indexed: 09/18/2023]
Abstract
In this review, we describe the application of shaped pulses for EPR spectroscopy. Pulses generated by fast arbitrary waveform generators are mostly used in the field of EPR spectroscopy for broadband (200 MHz-1 GHz) excitation of paramagnetic species. The implementation and optimization of such broadband pulses in existing EPR spectrometers, often designed and optimized for short rectangular microwave pulses, is demanding. Therefore, a major part of this review will describe in detail the implementation, testing and optimization of shaped pulses in existing EPR spectrometers. Additionally, we review applications using such pulses for broadband inversion of longitudinal magnetization as well as for the creation and manipulation of transverse magnetization in the field of dipolar and hyperfine EPR spectroscopy. They demonstrate the great potential of shaped pulses to improve the performance of pulsed EPR experiments. We give a brief theoretical description of shaped pulses and their limitations, especially for adiabatic pulses, most often used in EPR. We believe that this review can on the one hand be of practical use to EPR groups starting to work with such pulses, and on the other hand give readers an overview of the state of the art of shaped pulse applications in EPR spectroscopy.
Collapse
Affiliation(s)
- Burkhard Endeward
- Institute of Physical and Theoretical Chemistry and Center of Biomolecular Magnetic Resonance, Goethe University Frankfurt, Max-von-Laue Str. 7, 60438 Frankfurt am Main, Germany
| | - Matthias Bretschneider
- Institute of Physical and Theoretical Chemistry and Center of Biomolecular Magnetic Resonance, Goethe University Frankfurt, Max-von-Laue Str. 7, 60438 Frankfurt am Main, Germany
| | - Paul Trenkler
- Institute of Physical and Theoretical Chemistry and Center of Biomolecular Magnetic Resonance, Goethe University Frankfurt, Max-von-Laue Str. 7, 60438 Frankfurt am Main, Germany
| | - Thomas F Prisner
- Institute of Physical and Theoretical Chemistry and Center of Biomolecular Magnetic Resonance, Goethe University Frankfurt, Max-von-Laue Str. 7, 60438 Frankfurt am Main, Germany.
| |
Collapse
|
35
|
Mishra SK, Suryaprakash N. Pure shift edited NMR methodologies for the extraction of Homo- and heteronuclear couplings with ultra-high resolution. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2023; 136-137:1-60. [PMID: 37716754 DOI: 10.1016/j.pnmrs.2023.02.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 01/20/2023] [Accepted: 02/01/2023] [Indexed: 09/18/2023]
Abstract
The scalar couplings that result in the splitting of the signals in the NMR spectrum arise due to the interaction of the nuclear spins, whereby the spin polarization is transmitted through chemical bonds. The interaction strengths depend inter alia on the number of consecutive chemical bonds intervening between the two interacting spins and on the molecular conformation. The pairwise interaction of many spins in a molecule resulting in a complex spectrum poses a severe challenge to analyse the spectrum and hence the determination of magnitudes and signs of homo- and heteronuclear couplings. The problem is more severe in the analysis of 1H spectra than the spectra of most of the other nuclei due to the often very small chemical shift dispersion. As a consequence, the straightforward analysis and the accurate extraction of the coupling constants from the 1H spectrum of a complex spin system continues to remain a challenge, and often may be a formidable task. Over the years, the several pure shift-based one-dimensional and two-dimensional methodologies have been developed by workers in the field, which provide broadband homonuclear decoupling of proton spectra, removing the complexity but at the cost of the very informative scalar couplings. To circumvent this problem, several one-dimensional and two-dimensional NMR experiments have been developed for the determination of homonuclear and heteronuclear couplings (nJHX, where n = 1,2,3) while retaining the high resolution obtained by implementing pure shift strategies. This review attempts to summarize the extensive work reported by a large number of researchers over the years for the accurate determination of homo- and heteronuclear scalar couplings.
Collapse
Affiliation(s)
- Sandeep Kumar Mishra
- Department of Physics and NMR Research Centre, Indian Institute of Science Education and Research, Pune 411008, India.
| | - N Suryaprakash
- NMR Research Centre and Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560012, India.
| |
Collapse
|
36
|
Sorce DJ, Michaeli S. On the geometric phases during radio frequency pulses with sine and cosine amplitude and frequency modulation. AIP ADVANCES 2023; 13:085210. [PMID: 37584043 PMCID: PMC10424156 DOI: 10.1063/5.0138779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 07/10/2023] [Indexed: 08/17/2023]
Abstract
In this work, we describe the formation of geometric phases during nonadiabatic frequency swept (FS) radio frequency (RF) pulses with sine amplitude modulation and cosine frequency modulation functions. The geometric phases during the FS pulse were analyzed using a Schrödinger equation formalism, and the unified analytical expression for the geometric phase was derived. We present the solutions for sub-geometric phase components incorporated in spinor wavefunctions for the RF Hamiltonian of spin ½ nuclei. We demonstrate that the geometric phases during sine/cosine RF pulses are opposite in signs for different initial conditions of the spinor and that geometric phases can accumulate in correspondence to different magnetization trajectories. The derived formalism could be extended for the evaluation of the geometric phases during a wide class of amplitude- and frequency-modulated pulses used in MRI and in high-resolution NMR.
Collapse
Affiliation(s)
- Dennis J. Sorce
- Independent Researcher, 6 Stonegate Court, Cockeysville, Maryland 21030, USA
| | - Shalom Michaeli
- Center for Magnetic Resonance Research, University of Minnesota, 2021 6th Street SE, Minneapolis, Minnesota 55455, USAs
| |
Collapse
|
37
|
Walder BJ, McBrayer JD, Harrison KL, Fritzsching KJ. Multipurpose Broadband NMR Inversion Sequences. J Phys Chem A 2023. [PMID: 37318142 DOI: 10.1021/acs.jpca.3c02445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Solution-state 2D correlation experiments increase signal-to-noise, provide improved resolution, and inform about molecular connectivity. NMR experiments are compromised when the nuclei have broad chemical shift ranges that exceed the bandwidth of the experiment. Spectra acquired under these conditions are unphasable and artifact-prone, and peaks may disappear from the spectrum altogether. Existing remedies provide usable spectra only in specific experimental contexts. Here, we introduce a general broadband strategy that leads to a library of high performing NMR experiments. We achieve arbitrary and independent evolution of NMR interactions by only changing delays in our pulse block, letting the block replace inversion elements in any NMR experiment. The experiments improve the experimental bandwidth for both nuclei by an order of magnitude over conventional sequences, covering chemical shift ranges of most molecules, even at ultrahigh field. This library enables robust spectroscopy of molecules such as perfluorinated oils (19F{13C}) and fluorophosphorous compounds in battery electrolytes (19F{31P}).
Collapse
Affiliation(s)
- Brennan J Walder
- Sandia National Laboratories, 1611 Innovation Pkwy SE, Albuquerque, New Mexico 87123, United States
| | - Josefine D McBrayer
- Sandia National Laboratories, 1611 Innovation Pkwy SE, Albuquerque, New Mexico 87123, United States
| | - Katharine L Harrison
- Sandia National Laboratories, 1611 Innovation Pkwy SE, Albuquerque, New Mexico 87123, United States
| | - Keith J Fritzsching
- Sandia National Laboratories, 1611 Innovation Pkwy SE, Albuquerque, New Mexico 87123, United States
| |
Collapse
|
38
|
Froelich T, DelaBarre L, Wang P, Radder J, Torres E, Garwood M. Fast spin-echo approach for accelerated B 1 gradient-based MRI. Magn Reson Med 2023; 89:2204-2216. [PMID: 36669882 PMCID: PMC10050123 DOI: 10.1002/mrm.29592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 12/06/2022] [Accepted: 01/05/2023] [Indexed: 01/22/2023]
Abstract
PURPOSE To expand on the previously developedB 1 + $$ {\mathrm{B}}_1^{+} $$ -encoding technique, frequency-modulated Rabi-encoded echoes (FREE), to perform accelerated image acquisition by collecting multiple lines of k-space in an echo train. METHODS FREE uses adiabatic full-passage pulses and a spatially varying RF field to encode unique spatial information without the use of traditional B0 gradients. The original implementation relied on acquiring single lines of k-space, leading to long acquisitions. In this work, an acceleration scheme is presented in which multiple echoes are acquired in a single shot, analogous to conventional fast spin-echo sequences. Theoretical analysis and computer simulations investigated the feasibility of this approach and presented a framework to analyze important imaging parameters of FREE-based sequences. Experimentally, the multi-echo approach was compared with conventional phase-encoded images of the human visual cortex using a simple surface transceiver coil. Finally, different contrasts demonstrated the clinical versatility of the new accelerated sequence. RESULTS Images were acquired with an acceleration factor of 3.9, compared with the previous implementation of FREE, without exceeding specific absorption rate limits. Different contrasts can easily be acquired without major modifications, including inversion recovery-type images. CONCLUSION FREE initially illustrated the feasibility of performing slice-selective 2D imaging of the human brain without the need for a B0 gradient along the y-direction. The multi-echo version maintains the advantages thatB 1 + $$ {\mathrm{B}}_1^{+} $$ encoding provides but represents an important step toward improving the clinical feasibility of such sequences. Additional acceleration and more advanced reconstruction techniques could further improve the clinical viability of FREE-based techniques.
Collapse
Affiliation(s)
- Taylor Froelich
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Lance DelaBarre
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Paul Wang
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| | - Jerahmie Radder
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Efraín Torres
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| | - Michael Garwood
- Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
39
|
Anazodo UC, Wong DY, Théberge J, Dacey M, Gomes J, Penny JD, van Ginkel M, Poirier SE, McIntyre CW. Hemodialysis-Related Acute Brain Injury Demonstrated by Application of Intradialytic Magnetic Resonance Imaging and Spectroscopy. J Am Soc Nephrol 2023; 34:1090-1104. [PMID: 36890644 PMCID: PMC10278857 DOI: 10.1681/asn.0000000000000105] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 02/11/2023] [Indexed: 03/10/2023] Open
Abstract
SIGNIFICANCE STATEMENT Hemodialysis (HD) results in reduced brain blood flow, and HD-related circulatory stress and regional ischemia are associated with brain injury over time. However, studies to date have not provided definitive direct evidence of acute brain injury during a HD treatment session. Using intradialytic magnetic resonance imaging (MRI) and spectroscopy to examine HD-associated changes in brain structure and neurochemistry, the authors found that multiple white (WM) tracts had diffusion imaging changes characteristic of cytotoxic edema, a consequence of ischemic insult and a precursor to fixed structural WM injury. Spectroscopy showed decreases in prefrontal N -acetyl aspartate (NAA) and choline concentrations consistent with energy deficit and perfusion anomaly. This suggests that one HD session can cause brain injury and that studies of interventions that mitigate this treatment's effects on the brain are warranted. BACKGROUND Hemodialysis (HD) treatment-related hemodynamic stress results in recurrent ischemic injury to organs such as the heart and brain. Short-term reduction in brain blood flow and long-term white matter changes have been reported, but the basis of HD-induced brain injury is neither well-recognized nor understood, although progressive cognitive impairment is common. METHODS We used neurocognitive assessments, intradialytic anatomical magnetic resonance imaging, diffusion tensor imaging, and proton magnetic resonance spectroscopy to examine the nature of acute HD-associated brain injury and associated changes in brain structure and neurochemistry relevant to ischemia. Data acquired before HD and during the last 60 minutes of HD (during maximal circulatory stress) were analyzed to assess the acute effects of HD on the brain. RESULTS We studied 17 patients (mean age 63±13 years; 58.8% were male, 76.5% were White, 17.6% were Black, and 5.9% were of Indigenous ethnicity). We found intradialytic changes, including the development of multiple regions of white matter exhibiting increased fractional anisotropy with associated decreases in mean diffusivity and radial diffusivity-characteristic features of cytotoxic edema (with increase in global brain volumes). We also observed decreases in proton magnetic resonance spectroscopy-measured N -acetyl aspartate and choline concentrations during HD, indicative of regional ischemia. CONCLUSIONS This study demonstrates for the first time that significant intradialytic changes in brain tissue volume, diffusion metrics, and brain metabolite concentrations consistent with ischemic injury occur in a single dialysis session. These findings raise the possibility that HD might have long-term neurological consequences. Further study is needed to establish an association between intradialytic magnetic resonance imaging findings of brain injury and cognitive impairment and to understand the chronic effects of HD-induced brain injury. CLINICAL TRIALS INFORMATION NCT03342183 .
Collapse
Affiliation(s)
- Udunna C. Anazodo
- Lawson Health Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Dickson Y. Wong
- Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Jean Théberge
- Lawson Health Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Department of Medical Imaging, Western University, London, Ontario, Canada
| | - Madeleine Dacey
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Janice Gomes
- Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada
- Lilibeth Caberto Kidney Clinical Research Unit, London Health Sciences Centre, London, Ontario, Canada
| | - Jarrin D. Penny
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Lilibeth Caberto Kidney Clinical Research Unit, London Health Sciences Centre, London, Ontario, Canada
| | - Michael van Ginkel
- Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Stefan E. Poirier
- Lawson Health Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Christopher W. McIntyre
- Lawson Health Research Institute, London, Ontario, Canada
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
- Lilibeth Caberto Kidney Clinical Research Unit, London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
40
|
Qi X, Sun J, Zhu J, Kong D, Roberts N, Dong Y, Huang X, He Q, Xing H, Gong Q. SPatiotemporal-ENcoded acoustic radiation force imaging of focused ultrasound. Front Hum Neurosci 2023; 17:1184629. [PMID: 37180550 PMCID: PMC10172656 DOI: 10.3389/fnhum.2023.1184629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 04/03/2023] [Indexed: 05/16/2023] Open
Abstract
Neuromodulation technology has provided novel therapeutic approaches for diseases caused by neural circuit dysfunction. Transcranial focused ultrasound (FU) is an emerging neuromodulation approach that combines noninvasiveness with relatively sharp focus, even in deep brain regions. It has numerous advantages such as high precision and good safety in neuromodulation, allowing for modulation of both peripheral and central nervous systems. To ensure accurate treatment targeting in FU neuromodulation, a magnetic resonance acoustic radiation force imaging (MR-ARFI) sequence is crucial for the visualization of the focal point. Currently, the commonly used 2D Spin Echo ARFI (2D SE-ARFI) sequence suffers from the long acquisition time, while the echo planar imaging ARFI (EPI-ARFI) sequence with a shorter acquisition time is vulnerable to the magnetic field inhomogeneities. To address these problems, we proposed a spatiotemporal-encoded acoustic radiation force imaging sequence (i.e., SE-SPEN-ARFI, shortened to SPEN-ARFI) in this study. The displacement at the focal spot obtained was highly consistent with that of the SE-ARFI sequence. Our research shows that SPEN-ARFI allows for rapid image acquisition and has less image distortions even under great field inhomogeneities. Therefore, a SPEN-ARFI sequence is a practical alternative for the treatment planning in ultrasound neuromodulation.
Collapse
Affiliation(s)
- Xu Qi
- College of Physics, Sichuan University, Chengdu, China
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Jiayu Sun
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Jiayu Zhu
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Dechen Kong
- College of Physics, Sichuan University, Chengdu, China
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Neil Roberts
- College of Physics, Sichuan University, Chengdu, China
- Edinburgh Imaging and Centre for Reproductive Health (CFRH), Queen's Medical Research Institute, University of Edinburgh, Edinburgh, United Kingdom
| | - Yijing Dong
- Central Research Institute, United Imaging Healthcare Group, Shanghai, China
| | - Xiaoqi Huang
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
- Research Unit of Psychoradiology, Chinese Academy of Medical Sciences, Chengdu, China
| | - Qiang He
- Brain Laboratory, United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, China
| | - Haoyang Xing
- College of Physics, Sichuan University, Chengdu, China
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
- Research Unit of Psychoradiology, Chinese Academy of Medical Sciences, Chengdu, China
| | - Qiyong Gong
- Huaxi MR Research Center (HMRRC), Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
- Research Unit of Psychoradiology, Chinese Academy of Medical Sciences, Chengdu, China
| |
Collapse
|
41
|
Satrom KM, Rao RB, Tkáč I. Neonatal hyperbilirubinemia differentially alters the neurochemical profiles of the developing cerebellum and hippocampus in a preterm Gunn rat model. NMR IN BIOMEDICINE 2023:e4946. [PMID: 37009906 DOI: 10.1002/nbm.4946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 03/29/2023] [Accepted: 03/30/2023] [Indexed: 06/19/2023]
Abstract
Neonatal hyperbilirubinemia (NHB) can lead to brain injury in newborn infants by affecting specific regions including the cerebellum and hippocampus. Extremely preterm infants are more vulnerable to bilirubin neurotoxicity, but the mechanism and extent of injury is not well understood. A preterm version of the Gunn rat model was utilized to investigate severe preterm NHB. Homozygous/jaundiced Gunn rat pups were injected (i.p.) on postnatal day (P) 5 with sulfadimethoxine, which increases serum free bilirubin capable of crossing the blood-brain barrier and causing brain injury. The neurochemical profiles of the cerebellum and hippocampus were determined using in vivo 1 H MRS at 9.4 T on P30 and compared with those of heterozygous/non-jaundiced control rats. Transcript expression of related genes was determined by real-time quantitative PCR. MRI revealed significant morphological changes in the cerebellum of jaundiced rats. The concentrations of myo-inositol (+54%), glucose (+51%), N-acetylaspartylglutamate (+21%), and the sum of glycerophosphocholine and phosphocholine (+17%) were significantly higher in the cerebellum of the jaundiced group compared with the control group. Despite the lack of morphologic changes in the hippocampus, the concentration of myo-inositol (+9%) was higher and the concentrations of creatine (-8%) and of total creatine (-3%) were lower in the jaundiced group. In the hippocampus, expression of calcium/calmodulin dependent protein kinase II alpha (Camk2a), glucose transporter 1 (Glut1), and Glut3 transcripts were downregulated in the jaundiced group. In the cerebellum, glial fibrillary acidic protein (Gfap), myelin basic protein (Mbp), and Glut1 transcript expression was upregulated in the jaundiced group. These results indicate osmotic imbalance, gliosis, and changes in energy utilization and myelination, and demonstrate that preterm NHB critically affects brain development in a region-specific manner, with the cerebellum more severely impacted than the hippocampus.
Collapse
Affiliation(s)
- Katherine M Satrom
- Department of Pediatrics, Division of Neonatology, University of Minnesota, Minneapolis, MN, USA
| | - Raghavendra B Rao
- Department of Pediatrics, Division of Neonatology, University of Minnesota, Minneapolis, MN, USA
| | - Ivan Tkáč
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
42
|
Segawa TF, Igarashi R. Nanoscale quantum sensing with Nitrogen-Vacancy centers in nanodiamonds - A magnetic resonance perspective. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2023; 134-135:20-38. [PMID: 37321756 DOI: 10.1016/j.pnmrs.2022.12.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 11/30/2022] [Accepted: 12/07/2022] [Indexed: 06/17/2023]
Abstract
Nanodiamonds containing fluorescent Nitrogen-Vacancy (NV) centers are the smallest single particles, of which a magnetic resonance spectrum can be recorded at room temperature using optically-detected magnetic resonance (ODMR). By recording spectral shift or changes in relaxation rates, various physical and chemical quantities can be measured such as the magnetic field, orientation, temperature, radical concentration, pH or even NMR. This turns NV-nanodiamonds into nanoscale quantum sensors, which can be read out by a sensitive fluorescence microscope equipped with an additional magnetic resonance upgrade. In this review, we introduce the field of ODMR spectroscopy of NV-nanodiamonds and how it can be used to sense different quantities. Thereby we highlight both, the pioneering contributions and the latest results (covered until 2021) with a focus on biological applications.
Collapse
Affiliation(s)
- Takuya F Segawa
- Laboratory of Physical Chemistry, ETH Zurich, 8093 Zurich, Switzerland; Laboratory for Solid State Physics, ETH Zurich, 8093 Zurich, Switzerland.
| | - Ryuji Igarashi
- Institute for Quantum Life Science, National Institutes for Quantum Science and Technology, 4-9-1, Anagawa, Inage-Ku, Chiba 263-8555, Japan; Takasaki Advanced Radiation Research Institute, National Institutes for Quantum Science and Technology, 1233 Watanuki, Takasaki, Gunma 370-1292, Japan; JST, PRESTO, Kawaguchi, Japan.
| |
Collapse
|
43
|
Jerban S, Ma Y, Alenezi S, Moazamian D, Athertya J, Jang H, Dorthe E, Dlima D, Woods G, Chung CB, Chang EY, Du J. Ultrashort Echo Time (UTE) MRI porosity index (PI) and suppression ratio (SR) correlate with the cortical bone microstructural and mechanical properties: Ex vivo study. Bone 2023; 169:116676. [PMID: 36657630 PMCID: PMC9987215 DOI: 10.1016/j.bone.2023.116676] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 12/19/2022] [Accepted: 01/08/2023] [Indexed: 01/18/2023]
Abstract
Ultrashort echo time (UTE) MRI can image and consequently enable quantitative assessment of cortical bone. UTE-MRI-based evaluation of bone is largely underutilized due to the high cost and time demands of MRI in general. The signal ratio in dual-echo UTE imaging, known as porosity index (PI), as well as the signal ratio between UTE and inversion recovery UTE (IR-UTE) imaging, known as the suppression ratio (SR), are two rapid UTE-based bone evaluation techniques (∼ 5 mins scan time each), which can potentially reduce the time demand and cost in future clinical studies. This study aimed to investigate the correlations of PI and SR measures with cortical bone microstructural and mechanical properties. Cortical bone strips (n = 135) from tibial and femoral midshafts of 37 donors (61 ± 24 years old) were scanned using a dual-echo 3D Cones UTE sequence and a 3D Cones IR-UTE sequence for PI and SR calculations, respectively. Average bone mineral density, porosity, and pore size were measured using microcomputed tomography (μCT). Bone mechanical properties were measured using 4-point bending tests. The μCT measures showed significant correlations with PI (moderate to strong, R = 0.68-0.71) and SR (moderate, R = 0.58-0.68). Young's modulus, yield stress, and ultimate stress demonstrated significant moderate correlations with PI and SR (R = 0.52-0.62) while significant strong correlations with μCT measures (R > 0.7). PI and SR can potentially serve as fast and noninvasive (non-ionizing radiation) biomarkers for evaluating cortical bone in various bone diseases.
Collapse
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA; Department of Orthopedic Surgery, University of California, San Diego, La Jolla, CA, USA.
| | - Yajun Ma
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA
| | - Salem Alenezi
- Research and Laboratories Sector, Saudi Food and Drug Authority, Riyadh, Kingdom of Saudi Arabia
| | - Dina Moazamian
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Jiyo Athertya
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA
| | - Erik Dorthe
- Shiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA
| | - Darryl Dlima
- Shiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA
| | - Gina Woods
- Department of Medicine, University of California, San Diego, La Jolla, CA, USA
| | - Christine B Chung
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA
| | - Eric Y Chang
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA
| | - Jiang Du
- Department of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA.
| |
Collapse
|
44
|
Rangadurai AK, Toyama Y, Kay LE. Sometimes pulses just have to be perfect - An example based on the measurement of amide proton transverse relaxation rates in proteins. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 349:107412. [PMID: 36907132 DOI: 10.1016/j.jmr.2023.107412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 02/17/2023] [Accepted: 02/19/2023] [Indexed: 06/18/2023]
Abstract
The measurement of spin relaxation rates provides a unique avenue for quantifying dynamic processes in biomolecules. In order to simplify analysis of the measurements so that a few key intuitive parameters can be extracted, it is often the case that experiments are designed to eliminate interference effects between different classes of spin relaxation. One example emerges in the measurement of amide proton (1HN) transverse relaxation rates in 15N labeled proteins, where 15N inversion pulses are applied during a relaxation element to eliminate cross-correlated spin relaxation between 1HN-15N dipole-1HN CSA interactions. We show that unless these pulses are essentially perfect, significant oscillations in magnetization decay profiles can be obtained, due to the excitation of multiple-quantum coherences, leading potentially to errors in measured R2 rates. With the recent development of experiments for quantifying electrostatic potentials via amide proton relaxation rates, the need for highly accurate measurement schemes becomes critical. Straightforward modifications to existing pulse sequences are suggested to achieve this goal.
Collapse
Affiliation(s)
- Atul Kaushik Rangadurai
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Biochemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Chemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Hospital for Sick Children, Program in Molecular Medicine, 555 University Avenue, Toronto, Ontario M5G 1X8, Canada.
| | - Yuki Toyama
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Biochemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Chemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada.
| | - Lewis E Kay
- Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Biochemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Department of Chemistry, University of Toronto, Toronto, Ontario M5S 1A8, Canada; Hospital for Sick Children, Program in Molecular Medicine, 555 University Avenue, Toronto, Ontario M5G 1X8, Canada.
| |
Collapse
|
45
|
Pala S, Hänninen NE, Nykänen O, Liimatainen T, Nissi MJ. New methods for robust continuous wave T 1ρ relaxation preparation. NMR IN BIOMEDICINE 2023; 36:e4834. [PMID: 36115012 PMCID: PMC10078184 DOI: 10.1002/nbm.4834] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 09/08/2022] [Accepted: 09/12/2022] [Indexed: 06/15/2023]
Abstract
Measurement of the longitudinal relaxation time in the rotating frame of reference (T1ρ ) is sensitive to the fidelity of the main imaging magnetic field (B0 ) and that of the RF pulse (B1 ). The purpose of this study was to introduce methods for producing continuous wave (CW) T1ρ contrast with improved robustness against field inhomogeneities and to compare the sensitivities of several existing and the novel T1ρ contrast generation methods with the B0 and B1 field inhomogeneities. Four hard-pulse and four adiabatic CW-T1ρ magnetization preparations were investigated. Bloch simulations and experimental measurements at different spin-lock amplitudes under ideal and non-ideal conditions, as well as theoretical analysis of the hard-pulse preparations, were conducted to assess the sensitivity of the methods to field inhomogeneities, at low (ω1 << ΔB0 ) and high (ω1 >> ΔB0 ) spin-locking field strengths. In simulations, previously reported single-refocus and new triple-refocus hard-pulse and double-refocus adiabatic preparation schemes were found to be the most robust. The mean normalized absolute deviation between the experimentally measured relaxation times under ideal and non-ideal conditions was found to be smallest for the refocused preparation schemes and broadly in agreement with the sensitivities observed in simulations. Experimentally, all refocused preparations performed better than those that were non-refocused. The findings promote the use of the previously reported hard-pulse single-refocus ΔB0 and B1 insensitive T1ρ as a robust method with minimal RF energy deposition. The double-refocus adiabatic B1 insensitive rotation-4 CW-T1ρ preparation offers further improved insensitivity to field variations, but because of the extra RF deposition, may be preferred for ex vivo applications.
Collapse
Affiliation(s)
- Swetha Pala
- Department of Applied PhysicsUniversity of Eastern FinlandKuopioFinland
| | - Nina E. Hänninen
- Department of Applied PhysicsUniversity of Eastern FinlandKuopioFinland
- Research Unit of Medical Imaging, Physics and TechnologyUniversity of OuluOuluFinland
| | - Olli Nykänen
- Department of Applied PhysicsUniversity of Eastern FinlandKuopioFinland
- Research Unit of Medical Imaging, Physics and TechnologyUniversity of OuluOuluFinland
| | - Timo Liimatainen
- Research Unit of Medical Imaging, Physics and TechnologyUniversity of OuluOuluFinland
- Department of RadiologyOulu University HospitalOuluFinland
| | - Mikko J. Nissi
- Department of Applied PhysicsUniversity of Eastern FinlandKuopioFinland
- Research Unit of Medical Imaging, Physics and TechnologyUniversity of OuluOuluFinland
| |
Collapse
|
46
|
Yang Y, Wang C, Liu Y, Chen Z, Liu X, Zheng H, Liang D, Zhu Y. A robust adiabatic constant amplitude spin-lock preparation module for myocardial T 1ρ quantification at 3 T. NMR IN BIOMEDICINE 2023; 36:e4830. [PMID: 36093600 DOI: 10.1002/nbm.4830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 08/25/2022] [Accepted: 09/08/2022] [Indexed: 06/15/2023]
Abstract
T1ρ quantification has the potential to assess myocardial fibrosis without contrast agent. However, its preparation spin-lock pulse is sensitive to B1 and B0 inhomogeneities, resulting in severe banding artifacts in the heart region, especially at high magnetic field such as 3 T. We aimed to design a robust spin-lock (SL) preparation module that can be used in myocardial T1ρ quantification at 3 T. We used the tan/tanh pulse to tip up and tip down the magnetization in the spin-lock preparation module (tan/tanh-SL). Bloch simulation was used to optimize pulse shape parameters of the tan/tanh with a pulse duration (Tp ) of 8, 4, and 2 ms, respectively. The designed tan/tanh-SL modules were implemented on a 3-T MR scanner. They were evaluated in phantom studies under three different cases of B0 and B1 inhomogeneities, and tested in cardiac T1ρ quantification of healthy volunteers. The performance of the tan/tanh-SL was compared with the composite SL preparation pulses and the commonly used hyperbolic secant pulse for spin-lock (HS-SL). Feasible pulse shape parameters were obtained using Bloch simulation. Compared with HS-SL, the quantification error of tan/tanh-SL was reduced by 27.7% for Tp = 8 ms (mean ∆Q = 126.15 vs. 174.42) and 75.6% for Tp = 4 ms (mean ∆Q = 136.65 vs. 559.53). In the phantom study, tan/tanh-SL was less sensitive to B1 and B0 inhomogeneity compared with composite SL pulses and HS-SL. In cardiac T1ρ quantification, the T1ρ maps using tan/tanh-SL showed fewer banding artifacts than using composite SL pulses and HS-SL. The proposed tan/tanh-SL preparation module greatly improves the robustness to B0 and B1 field inhomogeneities and can be used in cardiac T1ρ quantification at 3 T.
Collapse
Affiliation(s)
- Yuxin Yang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Che Wang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Yuanyuan Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Zhongmin Chen
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Xin Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Dong Liang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Yanjie Zhu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| |
Collapse
|
47
|
Das S, Khaneja N. Composite pulse combinations for chirp excitation. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 347:107359. [PMID: 36563420 DOI: 10.1016/j.jmr.2022.107359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 12/13/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
Composite pulses are the efficient method for broadband excitation to get control of the limitations of high field NMR, such as resonance offset effects with constraints on rf power that leads to signal intensity distortion. Phase-modulated chirp pulses are used as ordered composite pulse sequences in this paper as CHORUS sequence in a high-field NMR spectrometer (BRUKER 750 MHz) for broadband excitation. The composite pulse sequence applies chirp pulses with the forward and the reverse sweep mechanisms. A single excitation pulse combines adiabatic and non-adiabatic rotation, explained as a three-phase rotation, which leaves the magnetizing vectors to a non-uniform phase dispersion as a function of the offset frequency. One adiabatic refocusing pulse of the double sweep rate after the excitation pulse cannot satisfactorily compensate for the phase dispersion. Hence, composite self-refocussing CHORUS excitation pulse, with forward, reverse, and their combinations are used to remove the non-uniform phase dispersion generated due to offset resonance frequency. Four such combinations of composite pulses are produced with analytical explanation in this paper. MATLAB simulation results and experimental verification on the BRUKER 750 MHz NMR spectrometer of the composite pulses are also presented in this paper.
Collapse
Affiliation(s)
- Sreya Das
- Systems and Control Engineering Department, Indian Institute of Technology, Bombay, India.
| | - Navin Khaneja
- Systems and Control Engineering Department, Indian Institute of Technology, Bombay, India
| |
Collapse
|
48
|
Ylä-Herttuala E, Vuorio T, Kettunen S, Laidinen S, Ylä-Herttuala S, Liimatainen T. Lymphatic insufficiency leads to distinct myocardial infarct content assessed by magnetic resonance T RAFFn, T 1ρ and T 2 relaxation times. Sci Rep 2023; 13:1579. [PMID: 36709358 PMCID: PMC9884273 DOI: 10.1038/s41598-023-28219-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 01/16/2023] [Indexed: 01/30/2023] Open
Abstract
The role of cardiac lymphatics in the pathogenesis of myocardial infarction (MI) is unclear. Lymphatic system regulates cardiac physiological processes such as edema and tissue fluid balance, which affect MI pathogenesis. Recently, MI and fibrosis have been assessed using endogenous contrast in magnetic resonance imaging (MRI) based on the relaxation along a fictitious field with rank n (RAFFn). We extended the RAFFn applications to evaluate the effects of lymphatic insufficiency on MI with comparison to longitudinal rotating frame (T1ρ) and T2 relaxation times. MI was induced in transgenic (TG) mice expressing soluble decoy VEGF receptor 3 that reduces lymphatic vessel formation and their wild-type (WT) control littermates for comparison. The RAFFn relaxation times with rank 2 (TRAFF2), and rank 4 (TRAFF4), T1ρ and T2 were acquired at time points 0, 3, 7, 21 and 42 days after the MI at 9.4 T. Infarct sizes were determined based on TRAFF2, TRAFF4, T1ρ and T2 relaxation time maps. The area of differences (AOD) was calculated based on the MI areas determined on T2 and TRAFF2, TRAFF4 or T1ρ relaxation time maps. Hematoxylin-eosin and Sirius red stained histology sections were prepared to confirm MI locations and sizes. MI was detected as increased TRAFF2, TRAFF4, T1ρ and T2 relaxation times. Infarct sizes were similar on all relaxation time maps during the experimental period. Significantly larger AOD values were found together with increased AOD values in the TG group compared to the WT group. Histology confirmed these findings. The lymphatic deficiency was found to increase cardiac edema in MI. The combination of TRAFF2 (or TRAFF4) and T2 characterizes MI and edema in the myocardium in both lymphatic insufficiency and normal mice without any contrast agents.
Collapse
Affiliation(s)
- Elias Ylä-Herttuala
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland.,Clinical Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Taina Vuorio
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Sanna Kettunen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Svetlana Laidinen
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
| | - Seppo Ylä-Herttuala
- A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland.,Heart Center and Gene Therapy Unit, Kuopio University Hospital, Kuopio, Finland
| | - Timo Liimatainen
- Research Unit of Medical Imaging, Physics and Technology, University of Oulu, P.O. Box 5000, 90014, Oulu, Finland. .,Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland.
| |
Collapse
|
49
|
Hui SC, Gong T, Zöllner HJ, Hupfeld KE, Gudmundson AT, Murali-Manohar S, Davies-Jenkins CW, Song Y, Chen Y, Oeltzschner G, Wang G, Edden RAE. sLASER and PRESS Perform Similarly at Revealing Metabolite-Age Correlations. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.18.524597. [PMID: 36711794 PMCID: PMC9882274 DOI: 10.1101/2023.01.18.524597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Purpose To compare the respective ability of PRESS and sLASER to reveal biological relationships, using age as a validation covariate. Methods MRS data were acquired from 102 healthy volunteers using PRESS and sLASER in centrum semiovale (CSO) and posterior cingulate cortex (PCC) regions. Acquisition parameters included TR/TE 2000/30 ms; 96 transients; 2048 datapoints sampled at 2 kHz.Spectra were analyzed using Osprey. Signal-to-noise ratio (SNR), full-width-half-maximum linewidth of tCr, and metabolite concentrations were extracted. A linear model was used to compare SNR and linewidth. Paired t-tests were used to assess differences in metabolite measurements between PRESS and sLASER. Correlations were used to evaluate the relationship between PRESS and sLASER metabolite estimates, as well as the strength of each metabolite-age relationship. Coefficients of variation were calculated to assess inter-subject variability in each metabolite measurement. Results SNR and linewidth were significantly higher (p<0.05) for sLASER than PRESS. Paired t-tests showed significant differences between PRESS and sLASER in most metabolite measurements. Metabolite measures were significantly correlated (p<0.05) for most metabolites between the two methods except GABA, Gln and Lac in CSO and GSH, Lac and NAAG in PCC. Metabolite-age relationships were consistently identified using both PRESS and sLASER. Similar CVs were observed for most metabolites. Conclusion The study results suggest strong agreement between PRESS and sLASER in identifying relationships between brain metabolites and age in CSO and PCC data acquired at 3T. sLASER is technically desirable due to the reduced chemical shift displacement artifact; however, PRESS performed similarly in 'good' brain regions at clinical field strength.
Collapse
Affiliation(s)
- Steve C.N. Hui
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Tao Gong
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Helge J. Zöllner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Kathleen E. Hupfeld
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Aaron T. Gudmundson
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Saipavitra Murali-Manohar
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Christopher W. Davies-Jenkins
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yulu Song
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Yufan Chen
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Georg Oeltzschner
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Guangbin Wang
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China
- Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China
| | - Richard A. E. Edden
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| |
Collapse
|
50
|
Harris AD, Amiri H, Bento M, Cohen R, Ching CRK, Cudalbu C, Dennis EL, Doose A, Ehrlich S, Kirov II, Mekle R, Oeltzschner G, Porges E, Souza R, Tam FI, Taylor B, Thompson PM, Quidé Y, Wilde EA, Williamson J, Lin AP, Bartnik-Olson B. Harmonization of multi-scanner in vivo magnetic resonance spectroscopy: ENIGMA consortium task group considerations. Front Neurol 2023; 13:1045678. [PMID: 36686533 PMCID: PMC9845632 DOI: 10.3389/fneur.2022.1045678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 12/06/2022] [Indexed: 01/06/2023] Open
Abstract
Magnetic resonance spectroscopy is a powerful, non-invasive, quantitative imaging technique that allows for the measurement of brain metabolites that has demonstrated utility in diagnosing and characterizing a broad range of neurological diseases. Its impact, however, has been limited due to small sample sizes and methodological variability in addition to intrinsic limitations of the method itself such as its sensitivity to motion. The lack of standardization from a data acquisition and data processing perspective makes it difficult to pool multiple studies and/or conduct multisite studies that are necessary for supporting clinically relevant findings. Based on the experience of the ENIGMA MRS work group and a review of the literature, this manuscript provides an overview of the current state of MRS data harmonization. Key factors that need to be taken into consideration when conducting both retrospective and prospective studies are described. These include (1) MRS acquisition issues such as pulse sequence, RF and B0 calibrations, echo time, and SNR; (2) data processing issues such as pre-processing steps, modeling, and quantitation; and (3) biological factors such as voxel location, age, sex, and pathology. Various approaches to MRS data harmonization are then described including meta-analysis, mega-analysis, linear modeling, ComBat and artificial intelligence approaches. The goal is to provide both novice and experienced readers with the necessary knowledge for conducting MRS data harmonization studies.
Collapse
Affiliation(s)
- Ashley D. Harris
- Department of Radiology, University of Calgary, Calgary, AB, Canada
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Houshang Amiri
- Neuroscience Research Center, Institute of Neuropharmacology, Kerman University of Medical Sciences, Kerman, Iran
| | - Mariana Bento
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Ronald Cohen
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Christopher R. K. Ching
- Imaging Genetics Center, Mark and Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, Los Angeles, CA, United States
| | - Christina Cudalbu
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Animal Imaging and Technology, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Emily L. Dennis
- TBI and Concussion Center, Department of Neurology, University of Utah, Salt Lake City, UT, United States
| | - Arne Doose
- Division of Psychological and Social Medicine and Developmental Neurosciences, Faculty of Medicine, Technische Universität Dresden, Dresden, Germany
| | - Stefan Ehrlich
- Division of Psychological and Social Medicine and Developmental Neurosciences, Faculty of Medicine, Technische Universität Dresden, Dresden, Germany
| | - Ivan I. Kirov
- Department of Radiology, Center for Advanced Imaging Innovation and Research, New York University Grossman School of Medicine, New York, NY, United States
| | - Ralf Mekle
- Center for Stroke Research Berlin, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Georg Oeltzschner
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Eric Porges
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Roberto Souza
- Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Department of Electrical and Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Friederike I. Tam
- Division of Psychological and Social Medicine and Developmental Neurosciences, Faculty of Medicine, Technische Universität Dresden, Dresden, Germany
| | - Brian Taylor
- Division of Diagnostic Imaging, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - Paul M. Thompson
- Imaging Genetics Center, Mark and Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, Los Angeles, CA, United States
| | - Yann Quidé
- School of Psychology, University of New South Wales (UNSW), Sydney, NSW, Australia
| | - Elisabeth A. Wilde
- TBI and Concussion Center, Department of Neurology, University of Utah, Salt Lake City, UT, United States
| | - John Williamson
- Department of Clinical and Health Psychology, College of Public Health and Health Professions, University of Florida, Gainesville, FL, United States
| | - Alexander P. Lin
- Center for Clinical Spectroscopy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, United States
| | - Brenda Bartnik-Olson
- Department of Radiology, Loma Linda University Medical Center, Loma Linda, CA, United States
| |
Collapse
|