1
|
Gerba CP, Boone S, Nims RW, Maillard JY, Sattar SA, Rubino JR, McKinney J, Ijaz MK. Mechanisms of action of microbicides commonly used in infection prevention and control. Microbiol Mol Biol Rev 2024:e0020522. [PMID: 38958456 DOI: 10.1128/mmbr.00205-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024] Open
Abstract
SUMMARYUnderstanding how commonly used chemical microbicides affect pathogenic microorganisms is important for formulation of microbicides. This review focuses on the mechanism(s) of action of chemical microbicides commonly used in infection prevention and control. Contrary to the typical site-specific mode of action of antibiotics, microbicides often act via multiple targets, causing rapid and irreversible damage to microbes. In the case of viruses, the envelope or protein capsid is usually the primary structural target, resulting in loss of envelope integrity or denaturation of proteins in the capsid, causing loss of the receptor-binding domain for host cell receptors, and/or breakdown of other viral proteins or nucleic acids. However, for certain virucidal microbicides, the nucleic acid may be a significant site of action. The region of primary damage to the protein or nucleic acid is site-specific and may vary with the virus type. Due to their greater complexity and metabolism, bacteria and fungi offer more targets. The rapid and irreversible damage to microbes may result from solubilization of lipid components and denaturation of enzymes involved in the transport of nutrients. Formulation of microbicidal actives that attack multiple sites on microbes, or control of the pH, addition of preservatives or potentiators, and so on, can increase the spectrum of action against pathogens and reduce both the concentrations and times needed to achieve microbicidal activity against the target pathogens.
Collapse
Affiliation(s)
- Charles P Gerba
- Department of Environmental Science, University of Arizona, Tucson, Arizona, USA
| | - Stephanie Boone
- Department of Environmental Science, University of Arizona, Tucson, Arizona, USA
| | | | - Jean-Yves Maillard
- School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff, Wales, United Kingdom
| | - Syed A Sattar
- Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | | | - Julie McKinney
- Global Research and Development for Lysol and Dettol, Reckitt Benckiser LLC, Montvale, New Jersey, USA
| | - M Khalid Ijaz
- Global Research and Development for Lysol and Dettol, Reckitt Benckiser LLC, Montvale, New Jersey, USA
| |
Collapse
|
2
|
Allende A, Férez-Rubio JA, Tudela JA, Aznar R, Gil MI, Sánchez G, Randazzo W. Human intestinal enteroids and predictive models validate the operational limits of sanitizers used for viral disinfection of vegetable process wash water. Int J Food Microbiol 2024; 413:110601. [PMID: 38301540 DOI: 10.1016/j.ijfoodmicro.2024.110601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 11/20/2023] [Accepted: 01/20/2024] [Indexed: 02/03/2024]
Abstract
Vegetables are globally associated with a considerable number of foodborne outbreaks caused by viral infections, specifically human norovirus. In fresh produce industry, washing represents a critical step for food safety as process wash water (PWW) needs to be maintained at appropriate microbial quality to prevent water-mediated cross-contamination. This study aimed to explore the disinfection efficacy of chlorine (free chlorine, FC), chlorine dioxide (ClO2) and peracetic acid (PAA) in PWW against infectious human norovirus and Tulane virus (TV). First, we tested the extent of TV inactivation in baby leaf, bell pepper, and vegetables mix PWW and monitored the viral decay by cell culture. Then, inactivation kinetics were defined for infectious human norovirus exposed to FC, ClO2 and PAA in baby leaves PWW using the human intestinal enteroids (HIE) system. Finally, kinetic inactivation models were fitted to TV reduction and decay of sanitizers to aid the implementation of disinfection strategies. Results showed that >8 log10 human norovirus and 3.9 log10 TV were inactivated by 20 ppm FC within 1 min; and by 3 ppm ClO2 in 1 min (TV) or 5 min (norovirus). PAA treatment at 80 ppm reduced ca. 2 log10 TV but not completely inactivated the virus even after 20 min exposure, while 5 min treatment prevented norovirus replication in HIE. TV inactivation in PWWs was described using an exponential decay model. Taking these data together, we demonstrated the value of applying the HIE model to validate current operational limits for the most commonly used sanitizers. The inactivation kinetics for human norovirus and TV, along with the predictive model described in this study expand the current knowledge to implement post-harvest produce safety procedures in industry settings.
Collapse
Affiliation(s)
- Ana Allende
- Research Group on Microbiology and Quality of Fruits and Vegetables (MxQ), Department of Food Science and Technology, CEBAS-CSIC, Campus Universitario de Espinardo, 25, 30100 Murcia, Spain
| | - José Antonio Férez-Rubio
- Research Group on Microbiology and Quality of Fruits and Vegetables (MxQ), Department of Food Science and Technology, CEBAS-CSIC, Campus Universitario de Espinardo, 25, 30100 Murcia, Spain
| | - Juan Antonio Tudela
- Research Group on Microbiology and Quality of Fruits and Vegetables (MxQ), Department of Food Science and Technology, CEBAS-CSIC, Campus Universitario de Espinardo, 25, 30100 Murcia, Spain
| | - Rosa Aznar
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna 46980, Valencia, Spain; Department of Microbiology and Ecology, University of Valencia, Valencia, Spain
| | - Maria Isabel Gil
- Research Group on Microbiology and Quality of Fruits and Vegetables (MxQ), Department of Food Science and Technology, CEBAS-CSIC, Campus Universitario de Espinardo, 25, 30100 Murcia, Spain
| | - Gloria Sánchez
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna 46980, Valencia, Spain
| | - Walter Randazzo
- Department of Preservation and Food Safety Technologies, Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna 46980, Valencia, Spain.
| |
Collapse
|
3
|
Wang Z, Yeo D, Kwon H, Zhang Y, Yoon D, Jung S, Hossain MI, Jeong MI, Choi C. Disinfection efficiency of chlorine dioxide and peracetic acid against MNV-1 and HAV in simulated soil-rich wash water. Food Res Int 2024; 175:113772. [PMID: 38129061 DOI: 10.1016/j.foodres.2023.113772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/06/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023]
Abstract
Wash water from fresh vegetables and root vegetables is an important vehicle for foodborne virus transmission. However, there is lack of assessing rapid viral inactivation strategies in wash water characterized by a high soil content at the post-harvest stage. Considering the significance of food safety during the washing stage for fresh and root vegetable produce prior to marketing, we assessed the inactivation efficacy by using chlorine dioxide (ClO2) and peracetic acid (PAA) against a surrogate of human norovirus (murine norovirus 1, MNV-1) and hepatitis A virus (HAV), in wash water containing black soil and clay loam. The results indicated that MNV-1 and HAV were reduced to the process limit of detection (PLOD), with reductions ranging from 4.89 to 6.35 log10 PFU, and 4.63 to 4.96 log10 PFU when treated with ClO2 at 2.5 ppm for 10 mins. Comparatively, when treated with 500 ppm of PAA for 10 mins, MNV-1 and HAV were maximum reduced to 1.75 ± 0.23 log10 PFU (4.50 log10 PFU reduction) and 2.13 ± 0.12 log10 PFU (2.72 log10 PFU reduction). This demonstrated the efficacy of ClO2 in eliminating foodborne viruses in soil-rich wash water. When we validated the recovery of the virus from two types of wash water, the pH (9.24 ± 0.33 and 5.95 ± 0.05) had no impact on the recovery of MNV-1, while the recovery of HAV was less than 1 %. By adjusting the pH to a neutral level, recovery of HAV and its RNA levels was increased to 15.94 and 3.89 %. Thus, this study emphasized the critical role of pH in the recovery of HAV from the complex soil-rich aqueous environment, and the efficacy of ClO2 serving as a pivotal reference for the development of control strategies against foodborne viruses in the supply chain of fresh and root vegetables.
Collapse
Affiliation(s)
- Zhaoqi Wang
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Daseul Yeo
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Hyojin Kwon
- Department of Food Science and Technology, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Yuan Zhang
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Danbi Yoon
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Soontag Jung
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Md Iqbal Hossain
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea
| | - Myeong-In Jeong
- National Institute of Agricultural Sciences, Wanju-gun, Jeollabuk-do 55365, Republic of Korea
| | - Changsun Choi
- Department of Food and Nutrition, College of Biotechnology and Natural Resources, Chung-Ang University, 4726, Gyeonggi-do 17546, Republic of Korea.
| |
Collapse
|
4
|
Oishi W, Sano D. Estimation of alkali dosage and contact time for treating human excreta containing viruses as an emergency response: a systematic review. Front Public Health 2023; 11:1286595. [PMID: 38026419 PMCID: PMC10667465 DOI: 10.3389/fpubh.2023.1286595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 10/31/2023] [Indexed: 12/01/2023] Open
Abstract
Water, sanitation, and hygiene provisions are essential during emergencies to prevent infectious disease outbreaks caused by improper human excreta management in settlements for people affected by natural disasters and conflicts. Human excreta disinfection is required when long-term containment in latrines is not feasible on-site. Alkali additives, including lime, are effective disinfectants for wastewater and faecal sludge containing large amounts of solid and dissolved organic matter. The aim of this study was to determine the minimum dose and contact time of alkali additives for treating virus-containing human excreta in emergency situations. We used literature data collected by searching Google Scholar and Web of Science. The date of the last search for each study was 31th May 2023. Only peer-reviewed articles that included disinfection practices in combination with quantitative data for the physicochemical data of a matrix and viral decay were selected for data extraction. Two reviewers independently collected data from each study. We extracted datasets from 14 studies that reported quantitative information about their disinfection tests, including viral decay over time, matrix types, and physicochemical properties. Three machine learning algorithms were applied to the collected dataset to determine the time required to achieve specified levels of virus inactivation under different environmental conditions. The best model was used to estimate the contact time to achieve a 3-log10 inactivation of RNA virus in wastewater and faeces. The most important variables for predicting the contact time were pH, temperature, and virus type. The estimated contact time for 3 log inactivation of RNA virus was <2 h at pH 12, which was achieved by adding 1.8 and 3.1% slaked lime to wastewater and faeces, respectively. The contact time decreased exponentially with the pH of the sludge and wastewater. In contrast, the pH of the sludge and wastewater increased linearly with the slaked lime dosage. Lime treatment is a promising measure where long-term containment in latrine is not feasible in densely populated areas, as 1 day is sufficient to inactivate viruses. The relationship we have identified between required contact time and lime dosage is useful for practitioners in determining appropriate treatment conditions of human waste.
Collapse
Affiliation(s)
- Wakana Oishi
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
| | - Daisuke Sano
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
- Department of Frontier Science for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Japan
| |
Collapse
|
5
|
Ouyang L, Wang N, Irudayaraj J, Majima T. Virus on surfaces: Chemical mechanism, influence factors, disinfection strategies, and implications for virus repelling surface design. Adv Colloid Interface Sci 2023; 320:103006. [PMID: 37778249 DOI: 10.1016/j.cis.2023.103006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 09/07/2023] [Accepted: 09/22/2023] [Indexed: 10/03/2023]
Abstract
While SARS-CoV-2 is generally under control, the question of variants and infections still persists. Fundamental information on how the virus interacts with inanimate surfaces commonly found in our daily life and when in contact with the skin will be helpful in developing strategies to inhibit the spread of the virus. Here in, a critically important review of current understanding of the interaction between virus and surface is summarized from chemistry point-of-view. The Derjaguin-Landau-Verwey-Overbeek and extended Derjaguin-Landau-Verwey-Overbeek theories to model virus attachments on surfaces are introduced, along with the interaction type and strength, and quantification of each component. The virus survival and transfer are affected by a combination of biological, physical, and chemical parameters, as well as environmental parameters. The surface properties for virus and virus survival on typical surfaces such as metals, plastics, and glass are summarized. Attention is also paid to the transfer of virus to/from surfaces and skin. Typical virus disinfection strategies utilizing heat, light, chemicals, and ozone are discussed together with their disinfection mechanism. In the last section, design principles for virus repelling surface chemistry such as surperhydrophobic or surperhydrophilic surfaces are also introduced, to demonstrate how the integration of surface property control and advanced material fabrication can lead to the development of functional surfaces for mitigating the effect of viral infection upon contact.
Collapse
Affiliation(s)
- Lei Ouyang
- State Key Laboratory of Biogeology and Environmental Geology, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China.
| | - Nan Wang
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Joseph Irudayaraj
- Department of Bioengineering, College of Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States
| | - Tetsuro Majima
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; The Institute of Scientific and Industrial Research (SANKEN), Osaka University, Ibaraki, Osaka 567-0047, Japan
| |
Collapse
|
6
|
Yang W, Li X, Chen R, Shen S, Xiao L, Li J, Dong F. Efficient purification of a nitrate and chlorate mixture in water via photoredox activated intermediate coupling-decoupling pathway. JOURNAL OF HAZARDOUS MATERIALS 2023; 458:131964. [PMID: 37399724 DOI: 10.1016/j.jhazmat.2023.131964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/13/2023] [Accepted: 06/27/2023] [Indexed: 07/05/2023]
Abstract
Nitrate (NO3-) is a widespread contaminant that threatens human health and ecological safety. Meanwhile, the disinfection byproducts chlorate (ClO3-) is generated inevitably in conventional wastewater treatment. Therefore, the contaminants mixture of NO3- and ClO3- are universal in common emission units. Photocatalysis technology is a feasible approach for the synergistic abatement of contaminant mixture, where matching suitable oxidation reactions is a potential strategy to improve the photocatalytic reduction reactions. Herein, formate (HCOOH) oxidation is introduced to facilitate the photocatalytic reduction of the NO3- and ClO3- mixture. As a result, high purification efficiency of NO3- and ClO3- mixture are achieved, evidenced by 84.6% e--dependent removal of the mixture at a reaction time of 30 min, with 94.5% N2 selectivity and 100% Cl- selectivity, respectively. Specifically, by the close combination of in-situ characterizations and theoretical calculations, the detailed reaction mechanism is revealed, in which the intermediate coupling-decoupling route from NO3- reduction and HCOOH oxidation is established by the chlorate-induced photoredox activation, leading to the significantly enhanced efficiency for the wastewater mixture purification. The practical application of this pathway is established for simulated wastewater to show its wide applicability. This work provides new insights into photoredox catalysis technology for its environmental application.
Collapse
Affiliation(s)
- Weiping Yang
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Xin Li
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Ruimin Chen
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Shujie Shen
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Lei Xiao
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| | - Jieyuan Li
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China.
| | - Fan Dong
- Research Center for Carbon-Neutral Environmental & Energy Technology, Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 611731, China
| |
Collapse
|
7
|
Liu H, Zhang J, Liu J, Cao G, Xu F, Li X. Bactericidal Mechanisms of Chlorine Dioxide against Beta-Hemolytic Streptococcus CMCC 32210. Curr Issues Mol Biol 2023; 45:5132-5144. [PMID: 37367075 DOI: 10.3390/cimb45060326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 06/07/2023] [Accepted: 06/08/2023] [Indexed: 06/28/2023] Open
Abstract
Chlorine dioxide is a globally recognized green and efficient disinfectant. This study aims to investigate the bactericidal mechanism of chlorine dioxide using beta-hemolytic Streptococcus (BHS) CMCC 32210 as a representative strain. BHS was exposed to chlorine dioxide, the minimum bactericidal concentration (MBC) values of chlorine dioxide against BHS were determined by the checkerboard method in preparation for subsequent tests. Cell morphology was observed using electron microscopy. Protein content leakage, adenosine triphosphatase (ATPase) activity, and lipid peroxidation were determined by kits, and DNA damage was determined using agar gel electrophoresis. The concentration of chlorine dioxide during disinfection showed a linear relationship with the concentration of BHS. Scanning electron microscopy (SEM) results showed that chlorine dioxide caused significant damage to the cell walls of BHS at a concentration of 50 mg/L, but had no significant effect on Streptococcus exposed to different exposure times. Furthermore, the extracellular protein concentration increased with increasing chlorine dioxide concentration, while the total protein content remained unchanged. The activities of Na+/K+-ATPase and Ca2+/Mg2+-ATPase decreased with increasing chlorine dioxide concentration. Chlorine dioxide treatment led to significant lipid peroxidation and DNA degradation in BHS. Leakage of intracellular components indicated that chlorine dioxide damaged the cell membrane of BHS. Chlorine dioxide exposure resulted in oxidative damage to lipids and proteins, which negatively impacted the cell wall and membrane of Streptococcus. This caused increased permeability and inactivation of key enzymes (Na+/K+-ATPase and Ca2+/Mg2+-ATPase) involved in respiratory metabolism, ultimately leading to DNA degradation and bacterial death due to either content leakage or metabolic failure.
Collapse
Affiliation(s)
- Huan Liu
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Jingju Zhang
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Jing Liu
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Guangjie Cao
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | - Fei Xu
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
- Key Laboratory of Animal Antimicrobial Resistance Surveillance, Ministry of Agriculture and Rural Affairs, Beijing 100081, China
| | - Xiubo Li
- National Feed Drug Reference Laboratories, Institute of Feed Research, Chinese Academy of Agricultural Sciences, Beijing 100081, China
- Key Laboratory of Animal Antimicrobial Resistance Surveillance, Ministry of Agriculture and Rural Affairs, Beijing 100081, China
| |
Collapse
|
8
|
Rashed AO, Huynh C, Merenda A, Rodriguez-Andres J, Kong L, Kondo T, Razal JM, Dumée LF. Dry-spun carbon nanotube ultrafiltration membranes tailored by anti-viral metal oxide coatings for human coronavirus 229E capture in water. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2023; 11:110176. [PMID: 37234558 PMCID: PMC10201849 DOI: 10.1016/j.jece.2023.110176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 04/21/2023] [Accepted: 05/20/2023] [Indexed: 05/28/2023]
Abstract
Although waterborne virus removal may be achieved using separation membrane technologies, such technologies remain largely inefficient at generating virus-free effluents due to the lack of anti-viral reactivity of conventional membrane materials required to deactivating viruses. Here, a stepwise approach towards simultaneous filtration and disinfection of Human Coronavirus 229E (HCoV-229E) in water effluents, is proposed by engineering dry-spun ultrafiltration carbon nanotube (CNT) membranes, coated with anti-viral SnO2 thin films via atomic layer deposition. The thickness and pore size of the engineered CNT membranes were fine-tuned by varying spinnable CNT sheets and their relative orientations on carbon nanofibre (CNF) porous supports to reach thicknesses less than 1 µm and pore size around 28 nm. The nanoscale SnO2 coatings were found to further reduce the pore size down to ∼21 nm and provide more functional groups on the membrane surface to capture the viruses via size exclusion and electrostatic attractions. The synthesized CNT and SnO2 coated CNT membranes were shown to attain a viral removal efficiency above 6.7 log10 against HCoV-229E virus with fast water permeance up to ∼4 × 103 and 3.5 × 103 L.m-2.h-1.bar-1, respectively. Such high performance was achieved by increasing the dry-spun CNT sheets up to 60 layers, orienting successive 30 CNT layers at 45°, and coating 40 nm SnO2 on the synthesized membranes. The current study provides an efficient scalable fabrication scheme to engineer flexible ultrafiltration CNT-based membranes for cost-effective filtration and inactivation of waterborne viruses to outperform the state-of-the-art ultrafiltration membranes.
Collapse
Affiliation(s)
- Ahmed O Rashed
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Chi Huynh
- LINTEC OF AMERICA, INC. Nano-Science and Technology Center, 2900 E. Plano Pkwy. Suite 100, Plano, TX 75074, United States
| | - Andrea Merenda
- School of Science, RMIT University, 124 La Trobe Street, Melbourne, VIC 3000, Australia
| | | | - Lingxue Kong
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Takeshi Kondo
- LINTEC OF AMERICA, INC. Nano-Science and Technology Center, 2900 E. Plano Pkwy. Suite 100, Plano, TX 75074, United States
| | - Joselito M Razal
- Deakin University, Geelong, Institute for Frontier Materials, 3216 Waurn Ponds, Victoria, Australia
| | - Ludovic F Dumée
- Khalifa University, Department of Chemical Engineering, Abu Dhabi, United Arab Emirates
- Research and Innovation Center on CO2 and Hydrogen, Khalifa University, Abu Dhabi, United Arab Emirates
- Center for Membrane and Advanced Water Technology, Khalifa University, Abu Dhabi, United Arab Emirates
| |
Collapse
|
9
|
Ali F, Lestari DL, Putri MD, Azmi KN. The effectiveness of chlorine dioxide gas in portable personal disinfectants to inhibit bacterial growth. JOURNAL OF WATER AND HEALTH 2023; 21:537-546. [PMID: 37254903 PMCID: wh_2023_191 DOI: 10.2166/wh.2023.191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Disinfectants, especially air disinfectants, are necessary to prevent the potential spread of pathogens (bacteria and viruses) in the pandemic era and minimize the spread of pathogens. Some of the commercial disinfectant products that are often used generally contain chlorine dioxide (ClO2) gas. This study tested the effectiveness of two different commercial disinfectants, a liquid stick disinfectant and a powder disinfection card, to carry out the disinfection of pathogenic bacteria in the environment. These two disinfectants were used as a medium for releasing chlorine dioxide gas which has a much stronger bactericidal effect. In the form of liquid stick, ClO2 is more effective in the disinfection process rather than in the form of powder. The effectiveness of the liquid disinfectant in inhibiting the growth of pathogenic bacteria is influenced by the temperature and the area of the open space covered. Considering that the release from both disinfectants used is very small (0.002 ppmv/h), it takes a small area to ensure that the disinfection process runs effectively.
Collapse
Affiliation(s)
- Firdaus Ali
- Environmental Engineering Study Program, Department of Civil Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, Depok City, Indonesia E-mail:
| | - Dwi Lintang Lestari
- Indonesia Water Institute, Rukan Tanjung Barat Indah No. F02, South Jakarta 12530, Indonesia
| | - Marsya Dyasthi Putri
- Indonesia Water Institute, Rukan Tanjung Barat Indah No. F02, South Jakarta 12530, Indonesia
| | - Khalidah Nurul Azmi
- Indonesia Water Institute, Rukan Tanjung Barat Indah No. F02, South Jakarta 12530, Indonesia
| |
Collapse
|
10
|
D’Accolti M, Soffritti I, Bini F, Mazziga E, Arnoldo L, Volta A, Bisi M, Antonioli P, Laurenti P, Ricciardi W, Vincenti S, Mazzacane S, Caselli E. Potential Use of a Combined Bacteriophage–Probiotic Sanitation System to Control Microbial Contamination and AMR in Healthcare Settings: A Pre-Post Intervention Study. Int J Mol Sci 2023; 24:ijms24076535. [PMID: 37047510 PMCID: PMC10095405 DOI: 10.3390/ijms24076535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 03/24/2023] [Accepted: 03/26/2023] [Indexed: 04/03/2023] Open
Abstract
Microbial contamination in the hospital environment is a major concern for public health, since it significantly contributes to the onset of healthcare-associated infections (HAIs), which are further complicated by the alarming level of antimicrobial resistance (AMR) of HAI-associated pathogens. Chemical disinfection to control bioburden has a temporary effect and can favor the selection of resistant pathogens, as observed during the COVID-19 pandemic. Instead, probiotic-based sanitation (probiotic cleaning hygiene system, PCHS) was reported to stably abate pathogens, AMR, and HAIs. PCHS action is not rapid nor specific, being based on competitive exclusion, but the addition of lytic bacteriophages that quickly and specifically kill selected bacteria was shown to improve PCHS effectiveness. This study aimed to investigate the effect of such combined probiotic–phage sanitation (PCHSφ) in two Italian hospitals, targeting staphylococcal contamination. The results showed that PCHSφ could provide a significantly higher removal of staphylococci, including resistant strains, compared with disinfectants (−76%, p < 0.05) and PCHS alone (−50%, p < 0.05). Extraordinary sporadic chlorine disinfection appeared compatible with PCHSφ, while frequent routine chlorine usage inactivated the probiotic/phage components, preventing PCHSφ action. The collected data highlight the potential of a biological sanitation for better control of the infectious risk in healthcare facilities, without worsening pollution and AMR concerns.
Collapse
Affiliation(s)
- Maria D’Accolti
- Section of Microbiology, Department of Chemical, Pharmaceutical and Agricultural Sciences, and LTTA, University of Ferrara, 44121 Ferrara, Italy; (M.D.)
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Irene Soffritti
- Section of Microbiology, Department of Chemical, Pharmaceutical and Agricultural Sciences, and LTTA, University of Ferrara, 44121 Ferrara, Italy; (M.D.)
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Francesca Bini
- Section of Microbiology, Department of Chemical, Pharmaceutical and Agricultural Sciences, and LTTA, University of Ferrara, 44121 Ferrara, Italy; (M.D.)
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Eleonora Mazziga
- Section of Microbiology, Department of Chemical, Pharmaceutical and Agricultural Sciences, and LTTA, University of Ferrara, 44121 Ferrara, Italy; (M.D.)
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Luca Arnoldo
- Department of Medicine, University of Udine, 33100 Udine, Italy
| | - Antonella Volta
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Matteo Bisi
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Paola Antonioli
- Department of Infection Prevention Control and Risk Management, S. Anna University Hospital, 44124 Ferrara, Italy
| | - Patrizia Laurenti
- Department of Health Sciences and Public Health, Section of Hygiene, Catholic University of the Sacred Heart, 00168 Rome, Italy
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy
| | - Walter Ricciardi
- Department of Health Sciences and Public Health, Section of Hygiene, Catholic University of the Sacred Heart, 00168 Rome, Italy
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy
| | - Sara Vincenti
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy
| | - Sante Mazzacane
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
| | - Elisabetta Caselli
- Section of Microbiology, Department of Chemical, Pharmaceutical and Agricultural Sciences, and LTTA, University of Ferrara, 44121 Ferrara, Italy; (M.D.)
- CIAS Research Center, University of Ferrara, 44122 Ferrara, Italy
- Correspondence:
| |
Collapse
|
11
|
Forés E, Mejías-Molina C, Ramos A, Itarte M, Hundesa A, Rusiñol M, Martínez-Puchol S, Esteve-Bricullé P, Espejo-Valverde A, Sirés I, Calvo M, Araujo RM, Girones R. Evaluation of pathogen disinfection efficiency of electrochemical advanced oxidation to become a sustainable technology for water reuse. CHEMOSPHERE 2023; 313:137393. [PMID: 36442679 DOI: 10.1016/j.chemosphere.2022.137393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/04/2022] [Accepted: 11/24/2022] [Indexed: 06/16/2023]
Abstract
Water treatment and reuse is gaining acceptance as a strategy to fight against water contamination and scarcity, but it usually requires complex treatments to ensure safety. Consequently, the electrochemical advanced processes have emerged as an effective alternative for water remediation. The main objective here is to perform a systematic study that quantifies the efficiency of a laboratory-scale electrochemical system to inactivate bacteria, bacterial spores, protozoa, bacteriophages and viruses in synthetic water, as well as in urban wastewater once treated in a wetland for reuse in irrigation. A Ti|RuO2-based plate and Si|BDD thin-film were comparatively employed as the anode, which was combined with a stainless-steel cathode in an undivided cell operating at 12 V. Despite the low resulting current density (<15 mA/cm2), both anodes demonstrated the production of oxidants in wetland effluent water. The disinfection efficiency was high for the bacteriophage MS2 (T99 in less than 7.1 min) and bacteria (T99 in about 30 min as maximum), but limited for CBV5 and TuV, spores and amoebas (T99 in more than 300 min). MS2 presented a rapid exponential inactivation regardless of the anode and bacteria showed similar sigmoidal curves, whereas human viruses, spores and amoebas resulted in linear profiles. Due the different sensitivity of microorganisms, different models must be considered to predict their inactivation kinetics. On this basis, it can be concluded that evaluating the viral inactivation from inactivation profiles determined for bacteria or some bacteriophages may be misleading. Therefore, neither bacteria nor bacteriophages are suitable models for the disinfection of water containing enteric viruses. The electrochemical treatment added as a final disinfection step enhances the inactivation of microorganisms, which could contribute to safe water reuse for irrigation. Considering the calculated low energy consumption, decentralized water treatment units powered by photovoltaic modules might be a near reality.
Collapse
Affiliation(s)
- Eva Forés
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Cristina Mejías-Molina
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Arantxa Ramos
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Itarte
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Ayalkibet Hundesa
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Marta Rusiñol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Sandra Martínez-Puchol
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain
| | - Pau Esteve-Bricullé
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Alejandro Espejo-Valverde
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Ignasi Sirés
- Laboratori d'Electroquímica dels Materials i del Medi Ambient, Departament de Ciència de Materials i Química Física, Secció de Química Física, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain
| | - Miquel Calvo
- Secció d'Estadística, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosa M Araujo
- Secció de Microbiologia, Virologia i Biotecnologia, Departament de Genètica, Microbiologia i Estadística, Universitat de Barcelona (UB), Barcelona, Spain
| | - Rosina Girones
- Laboratory of Viruses Contaminants of Water and Food, Departament de Genètica, Microbiologia i Estadística, Facultat de Biologia, Universitat de Barcelona (UB), Barcelona, Spain; Institut de Recerca de l'Aigua (IdRA), Universitat de Barcelona (UB), Barcelona, Spain.
| |
Collapse
|
12
|
Xu MY, Lin YL, Zhang TY, Hu CY, Tang YL, Deng J, Xu B. Chlorine dioxide-based oxidation processes for water purification:A review. JOURNAL OF HAZARDOUS MATERIALS 2022; 436:129195. [PMID: 35739725 DOI: 10.1016/j.jhazmat.2022.129195] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 05/14/2022] [Accepted: 05/18/2022] [Indexed: 06/15/2023]
Abstract
Chlorine dioxide (ClO2) has emerged as a broad-spectrum, safe, and effective disinfectant due to its high oxidation efficiency and reduced formation of organochlorinated by-products during application. This article provides an updated overview of ClO2-based oxidation processes used in water treatment. A systematic review of scientific information and experimental data on ClO2-based water purification procedures is presented. Concerning ClO2-based oxidation derivative problems, the pros and cons of ClO2-based combined processes are assessed and disinfection by-product (DBP) control approaches are proposed. The kinetic and mechanistic data on ClO2 reactivity towards micropollutants are discussed. ClO2 selectively reacts with electron-rich moieties (anilines, phenols, olefins, and amines) and eliminates certain inorganic ions and microorganisms with high efficiency. The formation of chlorite and chlorate during the oxidation process is a crucial concern when utilizing ClO2. Future applications include the combination of ClO2 with ferrous ions, activated carbon, ozone, UV, visible light, or persulfate processes. The combined process can reduce by-product generation while still ensuring ClO2 sterilization and disinfection. Overall, this research could provide useful information and new insights into the application of ClO2-based technologies.
Collapse
Affiliation(s)
- Meng-Yuan Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Yi-Li Lin
- Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 824, Taiwan, ROC
| | - Tian-Yang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Chen-Yan Hu
- College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, PR China
| | - Yu-Lin Tang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jing Deng
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou 310023, PR China
| | - Bin Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
13
|
Xiao S, Yuan Z, Huang Y. Disinfectants against SARS-CoV-2: A Review. Viruses 2022; 14:v14081721. [PMID: 36016342 PMCID: PMC9413547 DOI: 10.3390/v14081721] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/22/2022] [Accepted: 08/01/2022] [Indexed: 11/16/2022] Open
Abstract
The pandemic due to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has emerged as a serious global public health issue. Besides the high transmission rate from individual to individual, indirect transmission from inanimate objects or surfaces poses a more significant threat. Since the start of the outbreak, the importance of respiratory protection, social distancing, and chemical disinfection to prevent the spread of the virus has been the prime focus for infection control. Health regulatory organizations have produced guidelines for the formulation and application of chemical disinfectants to manufacturing industries and the public. On the other hand, extensive literature on the virucidal efficacy testing of microbicides for SARS-CoV-2 has been published over the past year and a half. This review summarizes the studies on the most common chemical disinfectants and their virucidal efficacy against SARS-CoV-2, including the type and concentration of the chemical disinfectant, the formulation, the presence of excipients, the exposure time, and other critical factors that determine the effectiveness of chemical disinfectants. In this review, we also critically appraise these disinfectants and conduct a discussion on the role they can play in the COVID-19 pandemic.
Collapse
Affiliation(s)
- Shuqi Xiao
- Wuhan Institute of Virology, Chinese Academy of Sciences, Wuhan 430020, China
| | - Zhiming Yuan
- National Biosafety Laboratory, Chinese Academy of Sciences, Wuhan 430020, China
| | - Yi Huang
- National Biosafety Laboratory, Chinese Academy of Sciences, Wuhan 430020, China
- Correspondence:
| |
Collapse
|
14
|
Hardison RL, Nelson SW, Barriga D, Ruiz NF, Ghere JM, Fenton GA, Lindstrom DJ, James RR, Stewart MJ, Lee SD, Calfee MW, Ryan SP, Howard MW. Evaluation of surface disinfection methods to inactivate the beta coronavirus Murine Hepatitis Virus. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:455-468. [PMID: 35687041 PMCID: PMC9547328 DOI: 10.1080/15459624.2022.2088768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The list of EPA-approved disinfectants for coronavirus features many products for use on hard, non-porous materials. There are significantly fewer products registered for use on porous materials. Further, many common, high-touch surfaces fall in between non-porous materials such as glass and porous materials such as soft fabrics. The objective of this study was to assess the efficacy of selected commercially available disinfectant products against coronaviruses on common, high-touch surfaces. Four disinfectants (Clorox Total 360, Bleach solution, Vital Oxide, and Peroxide Multi-Surface Cleaner) were evaluated against Murine Hepatitis Virus A59 (MHV) as a surrogate coronavirus for SARS-CoV-2. MHV in cell culture medium was inoculated onto four materials: stainless steel, latex-painted drywall tape, Styrene Butadiene rubber (rubber), and bus seat fabric. Immediately (T0) or 2-hr (T2) post-inoculation, disinfectants were applied by trigger-pull or electrostatic sprayer and either held for recommended contact times (Spray only) or immediately wiped (Spray and Wipe). Recovered infectious MHV was quantified by median tissue culture infectious dose assay. Bleach solution, Clorox Total 360, and Vital Oxide were all effective (>3-log10 reduction or complete kill of infectious virus) with both the Spray Only and Spray and Wipe methods on stainless steel, rubber, and painted drywall tape when used at recommended contact times at both T0 and T2 hr. Multi-Surface Cleaner unexpectedly showed limited efficacy against MHV on stainless steel within the recommended contact time; however, it showed increased (2.3 times greater efficacy) when used in the Spray and Wipe method compared to Spray Only. The only products to achieve a 3-log10 reduction on fabric were Vital Oxide and Clorox Total 360; however, the efficacy of Vital Oxide against MHV on fabric was reduced to below 3-log10 when applied by an electrostatic sprayer compared to a trigger-pull sprayer. This study highlights the importance of considering the material, product, and application method when developing a disinfection strategy for coronaviruses on high-touch surfaces.
Collapse
Affiliation(s)
| | | | - D. Barriga
- Battelle Memorial Institute, Columbus, Ohio
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Travis BJ, Elste J, Gao F, Joo BY, Cuevas‐Nunez M, Kohlmeir E, Tiwari V, Mitchell JC. Significance of chlorine-dioxide-based oral rinses in preventing SARS-CoV-2 cell entry. Oral Dis 2022; 28 Suppl 2:2481-2491. [PMID: 35841377 PMCID: PMC9349900 DOI: 10.1111/odi.14319] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 06/08/2022] [Accepted: 07/01/2022] [Indexed: 12/30/2022]
Abstract
OBJECTIVE This work aims to determine the efficacy of preprocedural oral rinsing with chlorine dioxide solutions to minimize the risk of coronavirus disease 2019 (COVID-19) transmission during high-risk dental procedures. METHODS The antiviral activity of chlorine-dioxide-based oral rinse (OR) solutions was tested by pre-incubating with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pseudovirus in a dosage-dependent manner before transducing to human embryonic kidney epithelial (HEK293T-ACE2) cells, which stably expresses ACE-2 receptor. Viral entry was determined by measuring luciferase activity using a luminescence microplate reader. In the cell-to-cell fusion assay, effector Chinese hamster ovary (CHO-K1) cells co-expressing spike glycoprotein of SARS-CoV-2 and T7 RNA polymerase were pre-incubated with the ORs before co-culturing with the target CHO-K1 cells co-expressing human ACE2 receptor and luciferase gene. The luciferase signal was quantified 24 h after mixing the cells. Surface expression of SARS-CoV-2 spike glycoprotein and ACE-2 receptor was confirmed using direct fluorescent imaging and quantitative cell-ELISA. Finally, dosage-dependent cytotoxic effects of ORs were evaluated at two different time points. RESULTS A dosage-dependent antiviral effect of the ORs was observed against SARS-CoV-2 cell entry and spike glycoprotein mediated cell-to-cell fusion. This demonstrates that ORs can be useful as a preprocedural step to reduce viral infectivity. CONCLUSIONS Chlorine-dioxide-based ORs have a potential benefit for reducing SARS-CoV-2 entry and spread.
Collapse
Affiliation(s)
- Briana Joy Travis
- College of Dental MedicineMidwestern UniversityDowners GroveIllinoisUSA
| | - James Elste
- Department of Microbiology and ImmunologyMidwestern UniversityDowners GroveIllinoisUSA
| | - Feng Gao
- College of Dental MedicineMidwestern UniversityDowners GroveIllinoisUSA
| | - Bo Young Joo
- Department of Microbiology and ImmunologyMidwestern UniversityDowners GroveIllinoisUSA
| | | | - Ellen Kohlmeir
- Core FacilityMidwestern University, IllinoisDowners GroveIllinoisUSA
| | - Vaibhav Tiwari
- Department of Microbiology and ImmunologyMidwestern UniversityDowners GroveIllinoisUSA
| | - John C. Mitchell
- College of Dental MedicineMidwestern UniversityDowners GroveIllinoisUSA
| |
Collapse
|
16
|
Direct and Activated Chlorine Dioxide Oxidation for Micropollutant Abatement: A Review on Kinetics, Reactive Sites, and Degradation Pathway. WATER 2022. [DOI: 10.3390/w14132028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Recently, ClO2-based oxidation has attracted increasing attention to micropollutant abatement, due to high oxidation potential, low disinfection byproduct (DBPs) formation, and easy technical implementation. However, the kinetics, reactive sites, activation methods, and degradation pathways involved are not fully understood. Therefore, we reviewed current literature on ClO2-based oxidation in micropollutant abatement. In direct ClO2 oxidation, the reactions of micropollutants with ClO2 followed second-order reaction kinetics (kapp = 10−3–106 M−1 s−1 at neutral pH). The kapp depends significantly on the molecular structures of the micropollutant and solution pH. The reactive sites of micropollutants start with certain functional groups with the highest electron densities including piperazine, sulfonyl amido, amino, aniline, pyrazolone, phenol groups, urea group, etc. The one-electron transfer was the dominant micropollutant degradation pathway, followed by indirect oxidation by superoxide anion radical (O2•−) or hydroxyl radical (•OH). In UV-activated ClO2 oxidation, the reactions of micropollutants followed the pseudo-first-order reaction kinetics with the rates of 1.3 × 10−4–12.9 s−1 at pH 7.0. Their degradation pathways include direct ClO2 oxidation, direct UV photolysis, ozonation, •OH-involved reaction, and reactive chlorine species (RCS)-involved reaction. Finally, we identified the research gaps and provided recommendations for further research. Therefore, this review gives a critical evaluation of ClO2-based oxidation in micropollutant abatement, and provides recommendations for further research.
Collapse
|
17
|
Lu S, Zhang G. Recent advances on inactivation of waterborne pathogenic microorganisms by (photo) electrochemical oxidation processes: Design and application strategies. JOURNAL OF HAZARDOUS MATERIALS 2022; 431:128619. [PMID: 35359104 DOI: 10.1016/j.jhazmat.2022.128619] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 02/18/2022] [Accepted: 03/01/2022] [Indexed: 06/14/2023]
Abstract
Compared with other conventional water disinfection processes, (photo) electrochemical oxidation (P/ECO) processes have the characteristics of environmental friendliness, convenient installation and operation, easy control and high efficiency of inactivating waterborne pathogenic microorganisms (PMs), so that more and more research work has been focused on this topic, but there is still a huge gap between the research and practical application. Here, the research network of inactivating PMs by P/ECO processes has been comprehensively summarized, and the electrode/reactor/process design strategies based on strengthening direct and indirect oxidation, enhancing mass transfer efficiency and electron transfer efficiency, and improving the effective dose of electrogenerated oxidants are discussed. Furthermore, the factors affecting the inactivation of PMs and the issues regarding to stability and lifetime of the electrode are discussed respectively. Finally, the important research priorities and possible research challenges of P/ECO processes are put forward to make significant progress of this technology.
Collapse
Affiliation(s)
- Sen Lu
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, PR China; School of Civil and Environmental Engineering, Harbin Institute of Technology, Shenzhen 518055, PR China
| | - Guan Zhang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, PR China; School of Civil and Environmental Engineering, Harbin Institute of Technology, Shenzhen 518055, PR China.
| |
Collapse
|
18
|
Sloan A, Kasloff SB, Cutts T. Mechanical Wiping Increases the Efficacy of Liquid Disinfectants on SARS-CoV-2. Front Microbiol 2022; 13:847313. [PMID: 35391722 PMCID: PMC8981239 DOI: 10.3389/fmicb.2022.847313] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Accepted: 02/03/2022] [Indexed: 12/24/2022] Open
Abstract
High-touch environmental surfaces are acknowledged as potential sources of pathogen transmission, particularly in health care settings where infectious agents may be readily abundant. Methods of disinfecting these surfaces often include direct application of a chemical disinfectant or simply wiping the surface with a disinfectant pre-soaked wipe (DPW). In this study, we examine the ability of four disinfectants, ethanol (EtOH), sodium hypochlorite (NaOCl), chlorine dioxide (ClO2), and potassium monopersulfate (KMPS), to inactivate SARS-CoV-2 on a hard, non-porous surface, assessing the effects of concentration and contact time. The efficacy of DPWs to decontaminate carriers spiked with SARS-CoV-2, as well as the transferability of the virus from used DPWs to clean surfaces, is also assessed. Stainless steel carriers inoculated with approximately 6 logs of SARS-CoV-2 prepared in a soil load were disinfected within 5 min through exposure to 66.5% EtOH, 0.5% NaOCl, and 1% KMPS. The addition of mechanical wiping using DPWs impregnated with these biocides rendered the virus inactive almost immediately, with no viral transfer from the used DPW to adjacent surfaces. Carriers treated with 100 ppm of ClO2 showed a significant amount of viable virus remaining after 10 min of biocide exposure, while the virus was only completely inactivated after 10 min of treatment with 500 ppm of ClO2. Wiping SARS-CoV-2-spiked carriers with DPWs containing either concentration of ClO2 for 5 s left significant amounts of viable virus on the carriers. Furthermore, higher titers of infectious virus retained on the ClO2-infused DPWs were transferred to uninoculated carriers immediately after wiping. Overall, 66.5% EtOH, 0.5% NaOCl, and 1% KMPS appear to be highly effective biocidal agents against SARS-CoV-2, while ClO2 formulations are much less efficacious.
Collapse
Affiliation(s)
| | | | - Todd Cutts
- National Microbiology Laboratory, Applied Biosafety Research Program, Safety and Environmental Services, Public Health Agency of Canada, Winnipeg, MB, Canada
| |
Collapse
|
19
|
Hossain F. Sources, enumerations and inactivation mechanisms of four emerging viruses in aqueous phase. JOURNAL OF WATER AND HEALTH 2022; 20:396-440. [PMID: 36366995 DOI: 10.2166/wh.2022.263] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Emergence and re-emergence of four types of severely infectious viruses have claimed significant numbers of lives when anthropogenic activities contribute to the mutagenesis of these pathogens and infectivity of these pathogens has been noticeably altered. However, both point and non-point sources can transport these viruses in water treatment and resource recovery facilities (RRF) where the presence of these pathogens in aerosolized form or in suspension can cause astronomical public health concerns. Hence, numerous scientific studies have been reviewed to comprehend the possible inactivation mechanisms of those viruses in aqueous phase where thermal-, photo-, and chemical-inactivation have confirmed their effectiveness in restraining those viruses and inactivation mechanisms are the major focuses to apprehend the quick and cost-effective virus removal process from water and RRF. Although practical applications of nano-sized disinfectants have challenged researchers, those disinfectants can completely kill the viruses and hamper RNA/DNA replication without any sign of reactivation or repair. Moreover, limitations and future research potential are discussed so that efficacious strategic management for a treatment facility can be developed at the forefront of fighting tactics against an epidemic or a pandemic. Enumerations, besides state-of-the-art detection techniques with gene sequences, are mentioned for these viruses.
Collapse
Affiliation(s)
- Fahim Hossain
- Department of Environmental Engineering, Imam Abdulrahman Bin Faisal University, Dammam, KSA E-mail:
| |
Collapse
|
20
|
OBINATA KAORU. New Countermeasures Against Infections with/after COVID-19: Is Chlorine Dioxide a Useful and Safe Disinfectant? JUNTENDO MEDICAL JOURNAL 2022. [DOI: 10.14789/jmj.jmj22-0030-r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- KAORU OBINATA
- Department of Prevention Medicine for Mass Infection, Juntendo University Graduate School of Medicine
| |
Collapse
|
21
|
Alahdal HM, AlYahya S, Ameen F, Sonbol H, Alomary MN. A review on Saudi Arabian wastewater treatment facilities and available disinfection methods: Implications to SARS-CoV-2 control. JOURNAL OF KING SAUD UNIVERSITY. SCIENCE 2021; 33:101574. [PMID: 34421280 PMCID: PMC8372479 DOI: 10.1016/j.jksus.2021.101574] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 08/04/2021] [Accepted: 08/10/2021] [Indexed: 05/28/2023]
Abstract
COVID-19 pandemic has severe impacts on human health and economy worldwide. Aerosols and droplets are the major routes of transmission of SARS-CoV-2 coronavirus causing COVID-19 disease. However, wastewater is a possible transmission pathway. Therefore, many studies have been published about the relation of wastewater and COVID-19 disease. Many studies have shown the presence of viral RNA in wastewater throughout the world recently. Therefore, research on wastewater treatments and disinfection methods are needed. Communities must make sure that the virus is not transmitted via treated wastewater. This review focuses on the Saudi Arabian wastewater treatment and disinfection techniques to assess the possibility of SARS-CoV-2 transmission through wastewaters. In view of the current pandemic situation, the wide analysis of wastewater treatments in Saudi Arabia is needed. The review gives guidelines to develop the wastewater treatment in Saudi Arabia.
Collapse
Affiliation(s)
- Hadil M Alahdal
- Department of Biology, College of Science, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Sami AlYahya
- National Center for Biotechnology, King Abdulaziz City for Science & Technology, Riyadh, Saudi Arabia
| | - Fuad Ameen
- Department of Botany & Microbiology, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Hana Sonbol
- Department of Biology, College of Science, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Mohammad N Alomary
- National Center for Biotechnology, King Abdulaziz City for Science & Technology, Riyadh, Saudi Arabia
| |
Collapse
|
22
|
Totaro M, Badalucco F, Costa AL, Tuvo B, Casini B, Privitera G, Menchini Fabris GB, Baggiani A. Effectiveness of Disinfection with Chlorine Dioxide on Respiratory Transmitted, Enteric, and Bloodborne Viruses: A Narrative Synthesis. Pathogens 2021; 10:pathogens10081017. [PMID: 34451481 PMCID: PMC8398083 DOI: 10.3390/pathogens10081017] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 08/04/2021] [Accepted: 08/10/2021] [Indexed: 11/23/2022] Open
Abstract
A viral spread occurrence such as the SARS-CoV-2 pandemic has prompted the evaluation of different disinfectants suitable for a wide range of environmental matrices. Chlorine dioxide (ClO2) represents one of the most-used virucidal agents in different settings effective against both enveloped and nonenveloped viruses. This narrative synthesis is focused on the effectiveness of ClO2 applied in healthcare and community settings in order to eliminate respiratory transmitted, enteric, and bloodborne viruses. Influenza viruses were reduced by 99.9% by 0.5–1.0 mg/L of ClO2 in less than 5 min. Higher concentration (20 mg/L) eliminated SARS-CoV-2 from sewage. ClO2 concentrations from 0.2 to 1.0 mg/L ensured at least a 99% viral reduction of AD40, HAV, Coxsackie B5 virus, and other enteric viruses in less than 30 min. Considering bloodborne viruses, 30 mg/L of ClO2 can eliminate them in 5 min. Bloodborne viruses (HIV-1, HCV, and HBV) may be completely eliminated from medical devices and human fluids after a treatment with 30 mg/L of ClO2 for 30 min. In conclusion, ClO2 is a versatile virucidal agent suitable for different environmental matrices.
Collapse
Affiliation(s)
- Michele Totaro
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | - Federica Badalucco
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | - Anna Laura Costa
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | - Benedetta Tuvo
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | - Beatrice Casini
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | - Gaetano Privitera
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
| | | | - Angelo Baggiani
- Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy; (M.T.); (F.B.); (A.L.C.); (B.T.); (B.C.); (G.P.)
- Correspondence: ; Tel.: +50-221-3583; Fax: +50-221-3588
| |
Collapse
|
23
|
Kuzniewski S. Prevalence, environmental fate, treatment strategies, and future challenges for wastewater contaminated with SARS-CoV-2. REMEDIATION (NEW YORK, N.Y.) 2021; 31:97-110. [PMID: 34539159 PMCID: PMC8441782 DOI: 10.1002/rem.21691] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been detected in untreated and treated wastewater and studies have shown that the concentration of SARS-CoV-2 is proportional to the prevalence of the coronavirus disease 2019 (COVID-19) in communities. This article presents a literature review of the prevalence of SARS-CoV-2 in wastewater, its environmental fate, recommended treatment strategies for contaminated wastewater, and treatment challenges to be faced in the future. The environmental fate of SARS-CoV-2 in wastewater is not straightforward because it can be a source of infection when present in the treated wastewater depending on the permeability of the wastewater treatment plant containment area, and can also leach into aquifers, which may serve as drinking water supplies. Secondly, there are different practices that can mitigate the SARS-CoV-2 infection rate from infected feces and urine. The World Health Organization has recommended the use of ultraviolet radiation (UV), disinfection, and filtration for wastewater contaminated with SARS-CoV-2, processes also common in wastewater treatment facilities. This article discusses these strategies referencing studies performed with surrogate viruses and shows that SARS-CoV-2 treatment can be complicated due to the interference from other aqueous chemical and physical factors. Considering that COVID-19 is not the first and certainly not the last pandemic, it is imperative to develop an effective multitreatment strategy for wastewater contaminated with contagious viruses and, preferably, those that are compatible with current wastewater treatment methods.
Collapse
|
24
|
Malka SK, Park MH. Fresh Produce Safety and Quality: Chlorine Dioxide's Role. FRONTIERS IN PLANT SCIENCE 2021; 12:775629. [PMID: 35087550 PMCID: PMC8787301 DOI: 10.3389/fpls.2021.775629] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 12/16/2021] [Indexed: 05/03/2023]
Abstract
Maintaining microbial safety and quality of fresh fruits and vegetables are a global concern. Harmful microbes can contaminate fresh produce at any stage from farm to fork. Microbial contamination can affect the quality and shelf-life of fresh produce, and the consumption of contaminated food can cause foodborne illnesses. Additionally, there has been an increased emphasis on the freshness and appearance of fresh produce by modern consumers. Hence, disinfection methods that not only reduce microbial load but also preserve the quality of fresh produce are required. Chlorine dioxide (ClO2) has emerged as a better alternative to chlorine-based disinfectants. In this review, we discuss the efficacy of gaseous and aqueous ClO2 in inhibiting microbial growth immediately after treatment (short-term effect) versus regulating microbial growth during storage of fresh produce (long-term effect). We further elaborate upon the effects of ClO2 application on retaining or enhancing the quality of fresh produce and discuss the current understanding of the mode of action of ClO2 against microbes affecting fresh produce.
Collapse
|