1
|
Duarte JMN. Challenges of Investigating Compartmentalized Brain Energy Metabolism Using Nuclear Magnetic Resonance Spectroscopy in vivo. Neurochem Res 2025; 50:73. [PMID: 39754627 DOI: 10.1007/s11064-024-04324-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Revised: 12/16/2024] [Accepted: 12/17/2024] [Indexed: 01/06/2025]
Abstract
Brain function requires continuous energy supply. Thus, unraveling brain metabolic regulation is critical not only for our basic understanding of overall brain function, but also for the cellular basis of functional neuroimaging techniques. While it is known that brain energy metabolism is exquisitely compartmentalized between astrocytes and neurons, the metabolic and neuro-energetic basis of brain activity is far from fully understood. 1H nuclear magnetic resonance (NMR) spectroscopy has been widely used to detect variations in metabolite levels, including glutamate and GABA, while 13C NMR spectroscopy has been employed to study metabolic compartmentation and to determine metabolic rates coupled brain activity, focusing mainly on the component corresponding to excitatory glutamatergic neurotransmission. The rates of oxidative metabolism in neurons and astrocytes are both associated with the rate of the glutamate-glutamine cycle between neurons and astrocytes. However, any possible correlation between energy metabolism pathways and the inhibitory GABAergic neurotransmission rate in the living brain remains to be experimentally demonstrated. That is due to low GABA levels, and the consequent challenge of determining GABAergic rates in a non-invasive manner. This brief review surveys the state-of-the-art analyses of energy metabolism in neurons and astrocytes contributing to glutamate and GABA synthesis using 13C NMR spectroscopy in vivo, and identifies limitations that need to be overcome in future studies.
Collapse
Affiliation(s)
- João M N Duarte
- Department of Experimental Medical Science, Faculty of Medicine, Lund University, Lund, Sweden.
- Wallenberg Centre for Molecular Medicine, Lund University, Lund, Sweden.
| |
Collapse
|
2
|
Rafiee Z, García-Serrano AM, Duarte JMN. Taurine Supplementation as a Neuroprotective Strategy upon Brain Dysfunction in Metabolic Syndrome and Diabetes. Nutrients 2022; 14:1292. [PMID: 35334949 PMCID: PMC8952284 DOI: 10.3390/nu14061292] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/14/2022] [Accepted: 03/15/2022] [Indexed: 02/07/2023] Open
Abstract
Obesity, type 2 diabetes, and their associated comorbidities impact brain metabolism and function and constitute risk factors for cognitive impairment. Alterations to taurine homeostasis can impact a number of biological processes, such as osmolarity control, calcium homeostasis, and inhibitory neurotransmission, and have been reported in both metabolic and neurodegenerative disorders. Models of neurodegenerative disorders show reduced brain taurine concentrations. On the other hand, models of insulin-dependent diabetes, insulin resistance, and diet-induced obesity display taurine accumulation in the hippocampus. Given the possible cytoprotective actions of taurine, such cerebral accumulation of taurine might constitute a compensatory mechanism that attempts to prevent neurodegeneration. The present article provides an overview of brain taurine homeostasis and reviews the mechanisms by which taurine can afford neuroprotection in individuals with obesity and diabetes. We conclude that further research is needed for understanding taurine homeostasis in metabolic disorders with an impact on brain function.
Collapse
Affiliation(s)
- Zeinab Rafiee
- Department of Experimental Medical Science, Faculty of Medicine, Lund University, 22100 Lund, Sweden; (Z.R.); (A.M.G.-S.)
- Wallenberg Centre for Molecular Medicine, Lund University, 22100 Lund, Sweden
| | - Alba M. García-Serrano
- Department of Experimental Medical Science, Faculty of Medicine, Lund University, 22100 Lund, Sweden; (Z.R.); (A.M.G.-S.)
- Wallenberg Centre for Molecular Medicine, Lund University, 22100 Lund, Sweden
| | - João M. N. Duarte
- Department of Experimental Medical Science, Faculty of Medicine, Lund University, 22100 Lund, Sweden; (Z.R.); (A.M.G.-S.)
- Wallenberg Centre for Molecular Medicine, Lund University, 22100 Lund, Sweden
| |
Collapse
|
3
|
El-Abtah ME, Talati P, Dietrich J, Gerstner ER, Ratai EM. Magnetic resonance spectroscopic imaging for detecting metabolic changes in glioblastoma after anti-angiogenic therapy—a systematic literature review. Neurooncol Adv 2022; 4:vdac103. [PMID: 35892047 PMCID: PMC9307101 DOI: 10.1093/noajnl/vdac103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
The impact of anti-angiogenic therapy (AAT) on patients with glioblastoma (GBM) is unclear due to a disconnect between radiographic findings and overall survivorship. MR spectroscopy (MRS) can provide clinically relevant information regarding tumor metabolism in response to AAT. This review explores the use of MRS to track metabolic changes in patients with GBM treated with AAT.
Methods
We conducted a systematic literature review in accordance with PRISMA guidelines to identify primary research articles that reported metabolic changes in GBMs treated with AAT. Collected variables included single or multi-voxel MRS acquisition parameters, metabolic markers, reported metabolic changes in response to AAT, and survivorship data.
Results
Thirty-five articles were retrieved in the initial query. After applying inclusion and exclusion criteria, 11 studies with 262 patients were included for qualitative synthesis with all studies performed using multi-voxel 1H MRS. Two studies utilized 31P MRS. Post-AAT initiation, shorter-term survivors had increased choline (cellular proliferation marker), increased lactate (a hypoxia marker), and decreased levels of the short echo time (TE) marker, myo-inositol (an osmoregulator and gliosis marker). MRS detected metabolic changes as soon as 1-day after AAT, and throughout the course of AAT, to predict survival. There was substantial heterogeneity in the timing of scans, which ranged from 1-day to 6–9 months after AAT initiation.
Conclusions
Multi-voxel MRS at intermediate and short TE can serve as a robust prognosticator of outcomes of patients with GBM who are treated with AAT.
Collapse
Affiliation(s)
- Mohamed E El-Abtah
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital , Charlestown, Massachusetts , USA
| | - Pratik Talati
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital , Charlestown, Massachusetts , USA
- Department of Neurological Surgery, Massachusetts General Hospital , Boston, Massachusetts , USA
| | - Jorg Dietrich
- Massachusetts General Hospital, Cancer Center , Boston, Massachusetts , USA
- Harvard Medical School , Boston, Massachusetts , USA
| | - Elizabeth R Gerstner
- Massachusetts General Hospital, Cancer Center , Boston, Massachusetts , USA
- Harvard Medical School , Boston, Massachusetts , USA
| | - Eva-Maria Ratai
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital , Charlestown, Massachusetts , USA
- Harvard Medical School , Boston, Massachusetts , USA
| |
Collapse
|
4
|
Hangel G, Spurny‐Dworak B, Lazen P, Cadrien C, Sharma S, Hingerl L, Hečková E, Strasser B, Motyka S, Lipka A, Gruber S, Brandner C, Lanzenberger R, Rössler K, Trattnig S, Bogner W. Inter-subject stability and regional concentration estimates of 3D-FID-MRSI in the human brain at 7 T. NMR IN BIOMEDICINE 2021; 34:e4596. [PMID: 34382280 PMCID: PMC11475238 DOI: 10.1002/nbm.4596] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 07/14/2021] [Accepted: 07/14/2021] [Indexed: 05/13/2023]
Abstract
PURPOSE Recently, a 3D-concentric ring trajectory (CRT)-based free induction decay (FID)-MRSI sequence was introduced for fast high-resolution metabolic imaging at 7 T. This technique provides metabolic ratio maps of almost the entire brain within clinically feasible scan times, but its robustness has not yet been thoroughly investigated. Therefore, we have assessed quantitative concentration estimates and their variability in healthy volunteers using this approach. METHODS We acquired whole-brain 3D-CRT-FID-MRSI at 7 T in 15 min with 3.4 mm nominal isometric resolution in 24 volunteers (12 male, 12 female, mean age 27 ± 6 years). Concentration estimate maps were calculated for 15 metabolites using internal water referencing and evaluated in 55 different regions of interest (ROIs) in the brain. Data quality, mean metabolite concentrations, and their inter-subject coefficients of variation (CVs) were compared for all ROIs. RESULTS Of 24 datasets, one was excluded due to motion artifacts. The concentrations of total choline, total creatine, glutamate, myo-inositol, and N-acetylaspartate in 44 regions were estimated within quality thresholds. Inter-subject CVs (mean over 44 ROIs/minimum/maximum) were 9%/5%/19% for total choline, 10%/6%/20% for total creatine, 11%/7%/24% for glutamate, 10%/6%/19% for myo-inositol, and 9%/6%/19% for N-acetylaspartate. DISCUSSION We defined the performance of 3D-CRT-based FID-MRSI for metabolite concentration estimate mapping, showing which metabolites could be robustly quantified in which ROIs with which inter-subject CVs expected. However, the basal brain regions and lesser-signal metabolites in particular remain as a challenge due susceptibility effects from the proximity to nasal and auditory cavities. Further improvement in quantification and the mitigation of B0 /B1 -field inhomogeneities will be necessary to achieve reliable whole-brain coverage.
Collapse
Affiliation(s)
- Gilbert Hangel
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
- Department of NeurosurgeryMedical University of ViennaViennaAustria
| | - Benjamin Spurny‐Dworak
- Division of General Psychiatry, Department of Psychiatry and PsychotherapyMedical University of ViennaViennaAustria
| | - Philipp Lazen
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Cornelius Cadrien
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
- Department of NeurosurgeryMedical University of ViennaViennaAustria
| | - Sukrit Sharma
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Lukas Hingerl
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Eva Hečková
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Bernhard Strasser
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Stanislav Motyka
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Alexandra Lipka
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
- Institute for Clinical Molecular MRIKarl Landsteiner SocietySt. PöltenAustria
| | - Stephan Gruber
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| | - Christoph Brandner
- High‐field MR Center, Center for Medical Physics and Biomedical EngineeringMedical University of ViennaViennaAustria
| | - Rupert Lanzenberger
- Division of General Psychiatry, Department of Psychiatry and PsychotherapyMedical University of ViennaViennaAustria
| | - Karl Rössler
- Department of NeurosurgeryMedical University of ViennaViennaAustria
| | - Siegfried Trattnig
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
- Institute for Clinical Molecular MRIKarl Landsteiner SocietySt. PöltenAustria
| | - Wolfgang Bogner
- High‐field MR Center, Department of Biomedical Imaging and Image‐guided TherapyMedical University of ViennaViennaAustria
| |
Collapse
|
5
|
Riemann LT, Aigner CS, Ellison SLR, Brühl R, Mekle R, Schmitter S, Speck O, Rose G, Ittermann B, Fillmer A. Assessment of measurement precision in single-voxel spectroscopy at 7 T: Toward minimal detectable changes of metabolite concentrations in the human brain in vivo. Magn Reson Med 2021; 87:1119-1135. [PMID: 34783376 DOI: 10.1002/mrm.29034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 09/14/2021] [Accepted: 09/16/2021] [Indexed: 12/13/2022]
Abstract
PURPOSE To introduce a study design and statistical analysis framework to assess the repeatability, reproducibility, and minimal detectable changes (MDCs) of metabolite concentrations determined by in vivo MRS. METHODS An unbalanced nested study design was chosen to acquire in vivo MRS data within different repeatability and reproducibility scenarios. A spin-echo, full-intensity acquired localized (SPECIAL) sequence was employed at 7 T utlizing three different inversion pulses: a hyperbolic secant (HS), a gradient offset independent adiabaticity (GOIA), and a wideband, uniform rate, smooth truncation (WURST) pulse. Metabolite concentrations, Cramér-Rao lower bounds (CRLBs) and coefficients of variation (CVs) were calculated. Both Bland-Altman analysis and a restricted maximum-likelihood estimation (REML) analysis were performed to estimate the different variance contributions of the repeatability and reproducibility of the measured concentration. A Bland-Altmann analysis of the spectral shape was performed to assess the variance of the spectral shape, independent of quantification model influences. RESULTS For the used setup, minimal detectable changes of brain metabolite concentrations were found to be between 0.40 µmol/g and 2.23 µmol/g. CRLBs account for only 16 % to 74 % of the total variance of the metabolite concentrations. The application of gradient-modulated inversion pulses in SPECIAL led to slightly improved repeatability, but overall reproducibility appeared to be limited by differences in positioning, calibration, and other day-to-day variations throughout different sessions. CONCLUSION A framework is introduced to estimate the precision of metabolite concentrations obtained by MRS in vivo, and the minimal detectable changes for 13 metabolite concentrations measured at 7 T using SPECIAL are obtained.
Collapse
Affiliation(s)
| | | | | | - Rüdiger Brühl
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| | - Ralf Mekle
- Center for Stroke Research Berlin, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | | | - Oliver Speck
- Biomedical Magnetic Resonance, Otto-von-Guericke University, Magdeburg, Germany.,Research Campus STIMULATE, Magdeburg, Germany
| | - Georg Rose
- Research Campus STIMULATE, Magdeburg, Germany.,Institut für Medizintechnik, Otto-von-Guericke University, Magdeburg, Germany
| | - Bernd Ittermann
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| | - Ariane Fillmer
- Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, Germany
| |
Collapse
|
6
|
El-Abtah ME, Wenke MR, Talati P, Fu M, Kim D, Weerasekera A, He J, Vaynrub A, Vangel M, Rapalino O, Andronesi O, Arrillaga-Romany I, Forst DA, Yen YF, Rosen B, Batchelor TT, Gonzalez RG, Dietrich J, Gerstner ER, Ratai EM. Myo-Inositol Levels Measured with MR Spectroscopy Can Help Predict Failure of Antiangiogenic Treatment in Recurrent Glioblastoma. Radiology 2021; 302:410-418. [PMID: 34751617 PMCID: PMC8805659 DOI: 10.1148/radiol.2021210826] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Background Patients with recurrent glioblastoma (GBM) are often treated with antiangiogenic agents, such as bevacizumab (BEV). Despite therapeutic promise, conventional MRI methods fail to help determine which patients may not benefit from this treatment. Purpose To use MR spectroscopic imaging (MRSI) with intermediate and short echo time to measure corrected myo-inositol (mI)normalized by contralateral creatine (hereafter, mI/c-Cr) in participants with recurrent GBM treated with BEV and to investigate whether such measurements can help predict survivorship before BEV initiation (baseline) and at 1 day, 4 weeks, and 8 weeks thereafter. Materials and Methods In this prospective longitudinal study (2016-2020), spectroscopic data on mI-a glial marker and osmoregulator within the brain-normalized by contralateral creatine in the intratumoral, contralateral, and peritumoral volumes of patients with recurrent GBM were evaluated. Area under the receiver operating characteristic curve (AUC) was calculated for all volumes at baseline and 1 day, 4 weeks, and 8 weeks after treatment to determine the ability of mI/c-Cr to help predict survivorship. Results Twenty-one participants (median age ± standard deviation, 62 years ± 12; 15 men) were evaluated. Lower mI/c-Cr in the tumor before and during BEV treatment was predictive of poor survivorship, with receiver operating characteristic analyses showing an AUC of 0.75 at baseline, 0.87 at 1 day after treatment, and 1 at 8 weeks after. A similar result was observed in contralateral normal-appearing tissue and the peritumoral volume, with shorter-term survivors having lower levels of mI/c-Cr. In the contralateral volume, a lower ratio of mI to creatine (hereafter, mI/Cr) predicted shorter-term survival at baseline and all other time points. Within the peritumoral volume, lower mI/c-Cr levels were predictive of shorter-term survival at baseline (AUC, 0.80), at 1 day after treatment (AUC, 0.93), and at 4 weeks after treatment (AUC, 0.68). Conclusion Lower levels of myo-inositol normalized by contralateral creatine within intratumoral, contralateral, and peritumoral volumes were predictive of poor survivorship and antiangiogenic treatment failure as early as before bevacizumab treatment. Adapting MR spectroscopic imaging alongside conventional MRI modalities conveys critical information regarding the biologic characteristics of tumors to help better treat individuals with recurrent glioblastoma. Clinical trial registration no. NCT02843230 © RSNA, 2021 Online supplemental material is available for this article.
Collapse
|
7
|
Ruiz-Rodado V, Brender JR, Cherukuri MK, Gilbert MR, Larion M. Magnetic resonance spectroscopy for the study of cns malignancies. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2021; 122:23-41. [PMID: 33632416 PMCID: PMC7910526 DOI: 10.1016/j.pnmrs.2020.11.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 11/20/2020] [Accepted: 11/22/2020] [Indexed: 05/04/2023]
Abstract
Despite intensive research, brain tumors are amongst the malignancies with the worst prognosis; therefore, a prompt diagnosis and thoughtful assessment of the disease is required. The resistance of brain tumors to most forms of conventional therapy has led researchers to explore the underlying biology in search of new vulnerabilities and biomarkers. The unique metabolism of brain tumors represents one potential vulnerability and the basis for a system of classification. Profiling this aberrant metabolism requires a method to accurately measure and report differences in metabolite concentrations. Magnetic resonance-based techniques provide a framework for examining tumor tissue and the evolution of disease. Nuclear Magnetic Resonance (NMR) analysis of biofluids collected from patients suffering from brain cancer can provide biological information about disease status. In particular, urine and plasma can serve to monitor the evolution of disease through the changes observed in the metabolic profiles. Moreover, cerebrospinal fluid can be utilized as a direct reporter of cerebral activity since it carries the chemicals exchanged with the brain tissue and the tumor mass. Metabolic reprogramming has recently been included as one of the hallmarks of cancer. Accordingly, the metabolic rewiring experienced by these tumors to sustain rapid growth and proliferation can also serve as a potential therapeutic target. The combination of 13C tracing approaches with the utilization of different NMR spectral modalities has allowed investigations of the upregulation of glycolysis in the aggressive forms of brain tumors, including glioblastomas, and the discovery of the utilization of acetate as an alternative cellular fuel in brain metastasis and gliomas. One of the major contributions of magnetic resonance to the assessment of brain tumors has been the non-invasive determination of 2-hydroxyglutarate (2HG) in tumors harboring a mutation in isocitrate dehydrogenase 1 (IDH1). The mutational status of this enzyme already serves as a key feature in the clinical classification of brain neoplasia in routine clinical practice and pilot studies have established the use of in vivo magnetic resonance spectroscopy (MRS) for monitoring disease progression and treatment response in IDH mutant gliomas. However, the development of bespoke methods for 2HG detection by MRS has been required, and this has prevented the wider implementation of MRS methodology into the clinic. One of the main challenges for improving the management of the disease is to obtain an accurate insight into the response to treatment, so that the patient can be promptly diverted into a new therapy if resistant or maintained on the original therapy if responsive. The implementation of 13C hyperpolarized magnetic resonance spectroscopic imaging (MRSI) has allowed detection of changes in tumor metabolism associated with a treatment, and as such has been revealed as a remarkable tool for monitoring response to therapeutic strategies. In summary, the application of magnetic resonance-based methodologies to the diagnosis and management of brain tumor patients, in addition to its utilization in the investigation of its tumor-associated metabolic rewiring, is helping to unravel the biological basis of malignancies of the central nervous system.
Collapse
Affiliation(s)
- Victor Ruiz-Rodado
- Neuro-Oncology Branch, National Cancer Institute, Center for Cancer Research, National Institute of Health, Bethesda, United States.
| | - Jeffery R Brender
- Radiation Biology Branch, Center for Cancer Research, National Institute of Health, Bethesda, United States
| | - Murali K Cherukuri
- Radiation Biology Branch, Center for Cancer Research, National Institute of Health, Bethesda, United States
| | - Mark R Gilbert
- Neuro-Oncology Branch, National Cancer Institute, Center for Cancer Research, National Institute of Health, Bethesda, United States
| | - Mioara Larion
- Neuro-Oncology Branch, National Cancer Institute, Center for Cancer Research, National Institute of Health, Bethesda, United States.
| |
Collapse
|
8
|
Berrington A, Voets NL, Larkin SJ, de Pennington N, Mccullagh J, Stacey R, Schofield CJ, Jezzard P, Clare S, Cadoux-Hudson T, Plaha P, Ansorge O, Emir UE. A comparison of 2-hydroxyglutarate detection at 3 and 7 T with long-TE semi-LASER. NMR IN BIOMEDICINE 2018; 31. [PMID: 29315915 DOI: 10.1002/nbm.3886] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 11/21/2017] [Accepted: 11/22/2017] [Indexed: 06/07/2023]
Abstract
Abnormally high levels of the 'oncometabolite' 2-hydroxyglutarate (2-HG) occur in many grade II and III gliomas, and correlate with mutations in the genes of isocitrate dehydrogenase (IDH) isoforms. In vivo measurement of 2-HG in patients, using magnetic resonance spectroscopy (MRS), has largely been carried out at 3 T, yet signal overlap continues to pose a challenge for 2-HG detection. To combat this, several groups have proposed MRS methods at ultra-high field (≥7 T) where theoretical increases in signal-to-noise ratio and spectral resolution could improve 2-HG detection. Long echo time (long-TE) semi-localization by adiabatic selective refocusing (semi-LASER) (TE = 110 ms) is a promising method for improved 2-HG detection in vivo at either 3 or 7 T owing to the use of broad-band adiabatic localization. Using previously published semi-LASER methods at 3 and 7 T, this study directly compares the detectability of 2-HG in phantoms and in vivo across nine patients. Cramér-Rao lower bounds (CRLBs) of 2-HG fitting were found to be significantly lower at 7 T (6 ± 2%) relative to 3 T (15 ± 7%) (p = 0.0019), yet were larger at 7 T in an IDH wild-type patient. Although no increase in SNR was detected at 7 T (77 ± 26) relative to 3 T (77 ± 30), the detection of 2-HG was greatly enhanced through an improved spectral profile and increased resolution at 7 T. 7 T had a large effect on pairwise fitting correlations between γ-aminobutyric acid (GABA) and 2-HG (p = 0.004), and resulted in smaller coefficients. The increased sensitivity for 2-HG detection using long-TE acquisition at 7 T may allow for more rapid estimation of 2-HG (within a few spectral averages) together with other associated metabolic markers in glioma.
Collapse
Affiliation(s)
- Adam Berrington
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | - Natalie L Voets
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | - Sarah J Larkin
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Nick de Pennington
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | | | - Richard Stacey
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | | | - Peter Jezzard
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | - Stuart Clare
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | - Tom Cadoux-Hudson
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Puneet Plaha
- Department of Neurosurgery, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Olaf Ansorge
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Uzay E Emir
- FMRIB Centre, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, UK
- School of Health Sciences, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
9
|
Tiwari V, An Z, Ganji SK, Baxter J, Patel TR, Pan E, Mickey BE, Maher EA, Pinho MC, Choi C. Measurement of glycine in healthy and tumorous brain by triple-refocusing MRS at 3 T in vivo. NMR IN BIOMEDICINE 2017; 30:10.1002/nbm.3747. [PMID: 28548710 PMCID: PMC5557683 DOI: 10.1002/nbm.3747] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Revised: 04/10/2017] [Accepted: 04/11/2017] [Indexed: 05/21/2023]
Abstract
Glycine (Gly) has been implicated in several neurological disorders, including malignant brain tumors. The precise measurement of Gly is challenging largely as a result of the spectral overlap with myo-inositol (mI). We report a new triple-refocusing sequence for the reliable co-detection of Gly and mI at 3 T and for the evaluation of Gly in healthy and tumorous brain. The sequence parameters were optimized with density-matrix simulations and phantom validation. With a total TE of 134 ms, the sequence gave complete suppression of the mI signal between 3.5 and 3.6 ppm and, consequently, well-defined Gly (3.55 ppm) and mI (3.64 ppm) peaks. In vivo 1 H magnetic resonance spectroscopy (MRS) data were acquired from the gray matter (GM)-dominant medial occipital and white matter (WM)-dominant left parietal regions in six healthy subjects, and analyzed with LCModel using in-house-calculated basis spectra. Tissue segmentation was performed to obtain the GM and WM contents within the MRS voxels. Metabolites were quantified with reference to GM-rich medial occipital total creatine at 8 mM. The Gly and mI concentrations were estimated to be 0.63 ± 0.05 and 8.6 ± 0.6 mM for the medial occipital and 0.34 ± 0.05 and 5.3 ± 0.8 mM for the left parietal regions, respectively. From linear regression of the metabolite estimates versus fractional GM content, the concentration ratios between pure GM and pure WM were estimated to be 2.6 and 2.1 for Gly and mI, respectively. Clinical application of the optimized sequence was performed in four subjects with brain tumor. The Gly levels in tumors were higher than those of healthy brain. Gly elevation was more extensive in a post-contrast enhancing region than in a non-enhancing region. The data indicate that the optimized triple-refocusing sequence may provide reliable co-detection of Gly and mI, and alterations of Gly in brain tumors can be precisely evaluated.
Collapse
Affiliation(s)
- Vivek Tiwari
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Zhongxu An
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Sandeep K. Ganji
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Jeannie Baxter
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Toral R. Patel
- Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Edward Pan
- Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Bruce E. Mickey
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Annette Strauss Center for Neuro-Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Elizabeth A. Maher
- Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Annette Strauss Center for Neuro-Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Marco C. Pinho
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Correspondence to: Changho Choi, PhD, Advanced Imaging Research Center, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, Texas 75390-8542,
| |
Collapse
|
10
|
Henning A. Proton and multinuclear magnetic resonance spectroscopy in the human brain at ultra-high field strength: A review. Neuroimage 2017; 168:181-198. [PMID: 28712992 DOI: 10.1016/j.neuroimage.2017.07.017] [Citation(s) in RCA: 74] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Revised: 06/27/2017] [Accepted: 07/10/2017] [Indexed: 12/11/2022] Open
Abstract
Magnetic Resonance Spectroscopy (MRS) allows for a non-invasive and non-ionizing determination of in vivo tissue concentrations and metabolic turn-over rates of more than 20 metabolites and compounds in the central nervous system of humans. The aim of this review is to give a comprehensive overview about the advantages, challenges and advances of ultra-high field MRS with regard to methodological development, discoveries and applications from its beginnings around 15 years ago up to the current state. The review is limited to human brain and spinal cord application at field strength of 7T and 9.4T and includes all relevant nuclei (1H, 31P, 13C).
Collapse
Affiliation(s)
- Anke Henning
- Max Plank Institute for Biological Cybernetics, Tübingen, Germany; Institute of Physics, Ernst-Moritz-Arndt University, Greifswald, Germany.
| |
Collapse
|
11
|
Gambarota G. Optimization of metabolite detection by quantum mechanics simulations in magnetic resonance spectroscopy. Anal Biochem 2017; 529:65-78. [DOI: 10.1016/j.ab.2016.08.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Revised: 07/31/2016] [Accepted: 08/22/2016] [Indexed: 10/21/2022]
|
12
|
Godlewska BR, Clare S, Cowen PJ, Emir UE. Ultra-High-Field Magnetic Resonance Spectroscopy in Psychiatry. Front Psychiatry 2017; 8:123. [PMID: 28744229 PMCID: PMC5504194 DOI: 10.3389/fpsyt.2017.00123] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 06/26/2017] [Indexed: 12/30/2022] Open
Abstract
The advantages of ultra-high-field (UHF ≥ 7T) MR have been demonstrated in a variety of MR acquisition modalities. Magnetic resonance spectroscopy (MRS) can particularly benefit from substantial gains in signal-to-noise ratio (SNR) and spectral resolution at UHF, enabling the quantification of numerous metabolites, including glutamate, glutamine, glutathione, and γ-aminobutyric acid that are relevant to psychiatric disorders. The aim of this review is to give an overview about the advantages and advances of UHF MRS and its application to psychiatric disorders. In order to provide a practical guide for potential applications of MRS at UHF, a literature review is given, surveying advantages and disadvantages of MRS at UHF. Key concepts, emerging technologies, practical considerations, and applications of UHF MRS are provided. Second, the strength of UHF MRS is demonstrated using some examples of its application in psychiatric disorders.
Collapse
Affiliation(s)
- Beata R Godlewska
- Department of Psychiatry, University of Oxford, Warneford Hospital, Oxford, United Kingdom
| | - Stuart Clare
- Oxford Centre for Functional MRI of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| | - Philip J Cowen
- Department of Psychiatry, University of Oxford, Warneford Hospital, Oxford, United Kingdom
| | - Uzay E Emir
- Oxford Centre for Functional MRI of the Brain, Nuffield Department of Clinical Neurosciences, University of Oxford, John Radcliffe Hospital, Oxford, United Kingdom
| |
Collapse
|
13
|
Xu H, Zhang H, Zhang J, Huang Q, Shen Z, Wu R. Evaluation of neuron-glia integrity by in vivo proton magnetic resonance spectroscopy: Implications for psychiatric disorders. Neurosci Biobehav Rev 2016; 71:563-577. [PMID: 27702600 DOI: 10.1016/j.neubiorev.2016.09.027] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2016] [Revised: 09/18/2016] [Accepted: 09/26/2016] [Indexed: 02/05/2023]
Abstract
Proton magnetic resonance spectroscopy (1H-MRS) has been widely applied in human studies. There is now a large literature describing findings of brain MRS studies with mental disorder patients including schizophrenia, bipolar disorder, major depressive disorder, and anxiety disorders. However, the findings are mixed and cannot be reconciled by any of the existing interpretations. Here we proposed the new theory of neuron-glia integrity to explain the findings of brain 1H-MRS stuies. It proposed the neurochemical correlates of neuron-astrocyte integrity and axon-myelin integrity on the basis of update of neurobiological knowledge about neuron-glia communication and of experimental MRS evidence for impairments in neuron-glia integrity from the authors and the other investigators. Following the neuron-glia integrity theories, this review collected evidence showing that glutamate/glutamine change is a good marker for impaired neuron-astrocyte integrity and that changes in N-acetylaspartate and lipid precursors reflect impaired myelination. Moreover, this new theory enables us to explain the differences between MRS findings in neuropsychiatric and neurodegenerative disorders.
Collapse
Affiliation(s)
- Haiyun Xu
- The Mental Health Center, Shantou University Medical College, China.
| | - Handi Zhang
- The Mental Health Center, Shantou University Medical College, China
| | - Jie Zhang
- The Mental Health Center, Shantou University Medical College, China
| | - Qingjun Huang
- The Mental Health Center, Shantou University Medical College, China
| | - Zhiwei Shen
- The Department of Radiology, the second affiliated hospital, Shantou University Medical College, China
| | - Renhua Wu
- The Department of Radiology, the second affiliated hospital, Shantou University Medical College, China
| |
Collapse
|
14
|
Wijtenburg SA, Yang S, Fischer BA, Rowland LM. In vivo assessment of neurotransmitters and modulators with magnetic resonance spectroscopy: application to schizophrenia. Neurosci Biobehav Rev 2015; 51:276-95. [PMID: 25614132 PMCID: PMC4427237 DOI: 10.1016/j.neubiorev.2015.01.007] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Revised: 01/02/2015] [Accepted: 01/08/2015] [Indexed: 12/28/2022]
Abstract
In vivo measurement of neurotransmitters and modulators is now feasible with advanced proton magnetic resonance spectroscopy ((1)H MRS) techniques. This review provides a basic tutorial of MRS, describes the methods available to measure brain glutamate, glutamine, γ-aminobutyric acid, glutathione, N-acetylaspartylglutamate, glycine, and serine at magnetic field strengths of 3T or higher, and summarizes the neurochemical findings in schizophrenia. Overall, (1)H MRS holds great promise for producing biomarkers that can serve as treatment targets, prediction of disease onset, or illness exacerbation in schizophrenia and other brain diseases.
Collapse
Affiliation(s)
- S Andrea Wijtenburg
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, PO Box 21247, Baltimore, MD 21228, USA.
| | - Shaolin Yang
- Department of Psychiatry, University of Illinois at Chicago, 1601 W. Taylor Street, Suite 512, Chicago, IL 60612, USA; Department of Radiology, University of Illinois at Chicago, 1601 W. Taylor Street, Suite 512, Chicago, IL 60612, USA; Department of Bioengineering, University of Illinois at Chicago, 1601 W. Taylor Street, Suite 512, Chicago, IL 60612, USA
| | - Bernard A Fischer
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, PO Box 21247, Baltimore, MD 21228, USA; Veterans Affairs Capital Network (VISN 5) Mental Illness Research, Education, and Clinical Center (MIRECC), Department of Veterans Affairs, 10 N. Greene Street, Baltimore, MD 21201, USA
| | - Laura M Rowland
- Maryland Psychiatric Research Center, Department of Psychiatry, University of Maryland School of Medicine, PO Box 21247, Baltimore, MD 21228, USA; Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 N. Wolfe Street, Baltimore, MD 21287, USA; Department of Psychology, University of Maryland, Baltimore County, Baltimore, MD 21228, USA
| |
Collapse
|
15
|
Ganji SK, Maher EA, Choi C. In vivo (1)H MRSI of glycine in brain tumors at 3T. Magn Reson Med 2015; 75:52-62. [PMID: 25651788 DOI: 10.1002/mrm.25588] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Revised: 11/06/2014] [Accepted: 11/28/2014] [Indexed: 01/10/2023]
Abstract
PURPOSE MR spectroscopic imaging (SI) of glycine (Gly) in the human brain is challenging due to the interference of the abundant neighboring J-coupled resonances. Our aim is to accomplish reliable imaging of Gly in healthy brain and brain tumors using an optimized MR sequence scheme at 3 tesla. METHODS Two-dimensional (1)H SI was performed with a point-resolved spectroscopy scheme. An echo time of 160 ms was used for separation between Gly and myo-inositol signals. Data were collected from eight healthy volunteers and 14 subjects with gliomas. Spectra were analyzed with the linear combination model using numerically calculated basis spectra. Metabolite concentrations were estimated with reference to creatine in white matter (WM) regions at 6.4 molar concentrations (mM). RESULTS From a linear regression analysis with respect to the fractional gray matter (GM) content, the Gly concentrations in pure GM and WM in healthy brains were estimated to be 1.1 and 0.3 mM, respectively. Gly was significantly elevated in tumors. The tumor-to-contralateral Gly concentration ratio was more extensive with higher grades, showing ∼ 10-fold elevation of Gly in glioblastomas. CONCLUSION The Gly level is significantly different between GM and WM in healthy brains. Our data indicate that SI of Gly may provide a biomarker of brain tumor malignancy.
Collapse
Affiliation(s)
- Sandeep K Ganji
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Elizabeth A Maher
- Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Annette Strauss Center for Neuro-Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Neurology and Neurotherapeutics, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Harold C. Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
16
|
Hulsey KM, Mashimo T, Banerjee A, Soesbe TC, Spence JS, Vemireddy V, Maher EA, Bachoo RM, Choi C. ¹H MRS characterization of neurochemical profiles in orthotopic mouse models of human brain tumors. NMR IN BIOMEDICINE 2015; 28:108-115. [PMID: 25394324 DOI: 10.1002/nbm.3231] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2014] [Revised: 10/03/2014] [Accepted: 10/06/2014] [Indexed: 06/04/2023]
Abstract
Glioblastoma (GBM), the most common primary brain tumor, is resistant to currently available treatments. The development of mouse models of human GBM has provided a tool for studying mechanisms involved in tumor initiation and growth as well as a platform for preclinical investigation of new drugs. In this study we used (1) H MR spectroscopy to study the neurochemical profile of a human orthotopic tumor (HOT) mouse model of human GBM. The goal of this study was to evaluate differences in metabolite concentrations in the GBM HOT mice when compared with normal mouse brain in order to determine if MRS could reliably differentiate tumor from normal brain. A TE =19 ms PRESS sequence at 9.4 T was used for measuring metabolite levels in 12 GBM mice and 8 healthy mice. Levels for 12 metabolites and for lipids/macromolecules at 0.9 ppm and at 1.3 ppm were reliably detected in all mouse spectra. The tumors had significantly lower concentrations of total creatine, GABA, glutamate, total N-acetylaspartate, aspartate, lipids/macromolecules at 0.9 ppm, and lipids/macromolecules at 1.3 ppm than did the brains of normal mice. The concentrations of glycine and lactate, however, were significantly higher in tumors than in normal brain.
Collapse
Affiliation(s)
- Keith M Hulsey
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Toncelli A, Noeske R, Cosottini M, Costagli M, Domenici V, Tiberi G, Tosetti M. STEAM-MiTiS: An MR spectroscopy method for the detection of scalar-coupled metabolites and its application to glutamate at 7 T. Magn Reson Med 2014; 74:1515-22. [DOI: 10.1002/mrm.25556] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2014] [Revised: 10/28/2014] [Accepted: 11/09/2014] [Indexed: 11/07/2022]
Affiliation(s)
| | - Ralph Noeske
- MR Applications and Workflow Development; GE Healthcare; Berlin Germany
| | - Mirco Cosottini
- Dipartimento di Ricerca Traslazionale e delle Nuove Tecnologie in Medicina e Chirurgia; University of Pisa; Pisa Italy
- Fondazione IMAGO7; Pisa Italy
| | - Mauro Costagli
- Fondazione IMAGO7; Pisa Italy
- Laboratorio di Fisica Medica e Biotecnologie per la Risonanza Magnetica IRCCS Fondazione Stella Maris; Pisa Italy
| | - Valentina Domenici
- Dipartimento di Chimica e Chimica Industriale; University of Pisa; Pisa Italy
| | - Gianluigi Tiberi
- Fondazione IMAGO7; Pisa Italy
- Laboratorio di Fisica Medica e Biotecnologie per la Risonanza Magnetica IRCCS Fondazione Stella Maris; Pisa Italy
| | - Michela Tosetti
- Fondazione IMAGO7; Pisa Italy
- Laboratorio di Fisica Medica e Biotecnologie per la Risonanza Magnetica IRCCS Fondazione Stella Maris; Pisa Italy
| |
Collapse
|
18
|
Duarte JM, Do KQ, Gruetter R. Longitudinal neurochemical modifications in the aging mouse brain measured in vivo by 1H magnetic resonance spectroscopy. Neurobiol Aging 2014; 35:1660-8. [DOI: 10.1016/j.neurobiolaging.2014.01.135] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 11/19/2013] [Accepted: 01/27/2014] [Indexed: 12/29/2022]
|
19
|
Maudsley AA, Gupta RK, Stoyanova R, Parra NA, Roy B, Sheriff S, Hussain N, Behari S. Mapping of glycine distributions in gliomas. AJNR Am J Neuroradiol 2014; 35:S31-6. [PMID: 24481330 DOI: 10.3174/ajnr.a3845] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
BACKGROUND AND PURPOSE Increased glycine concentration in the brain is associated with altered metabolism in cancer and can be detected by using in vivo MR spectroscopy. This has been proposed as a marker for grade IV gliomas; however, little is known about the potential significance and frequency of in vivo glycine observation. The purpose of this study was to examine the rate of occurrence and spatial distribution of glycine observation with respect to other MR imaging parameters. MATERIALS AND METHODS Data from volumetric whole-brain MR spectroscopic imaging of 59 subjects with glioma were analyzed with glycine included in the spectral model. The associations of the signal amplitude and spatial distributions of glycine with findings from contrast-enhanced T1, perfusion, and diffusion MR imaging were then examined. RESULTS Glycine was detected in 24% of all studies, though with a wide range of signal amplitude and extent of the spatial distributions. While more commonly seen in grade IV tumors (42% of studies), relatively large concentrations were also detected in grade II and III gliomas. Coanalysis with other metabolites indicated a strong association with choline and that glycine was frequently seen to be overlapping with, and adjacent to, areas of high lactate concentration. Increased glycine was always associated with contrast enhancement and areas of increased cerebral blood flow, but without any clear association with other image parameters. CONCLUSIONS Detection of increased glycine in gliomas appears to identify a subgroup of tumors and areas of increased proliferation.
Collapse
Affiliation(s)
- A A Maudsley
- From the Departments of Radiology (A.A.M., S.S.)
| | - R K Gupta
- Department of Radiology and Imaging (R.K.G., B.R.), Fortis Memorial Research Institute, Gurgaon, Haryana, India
| | - R Stoyanova
- Radiation Oncology (R.S., N.A.P.), University of Miami, Miami, Florida
| | - N A Parra
- Radiation Oncology (R.S., N.A.P.), University of Miami, Miami, Florida
| | - B Roy
- Department of Radiology and Imaging (R.K.G., B.R.), Fortis Memorial Research Institute, Gurgaon, Haryana, India
| | - S Sheriff
- From the Departments of Radiology (A.A.M., S.S.)
| | - N Hussain
- Department of Pathology (N.H.), Ram Manohar Lohia, Institute of Medical Sciences, Lucknow, India
| | - S Behari
- Department of Neurosurgery (S.B.), Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India
| |
Collapse
|
20
|
Wijnen JP, Idema AJS, Stawicki M, Lagemaat MW, Wesseling P, Wright AJ, Scheenen TWJ, Heerschap A. Quantitative short echo time 1H MRSI of the peripheral edematous region of human brain tumors in the differentiation between glioblastoma, metastasis, and meningioma. J Magn Reson Imaging 2012; 36:1072-82. [PMID: 22745032 DOI: 10.1002/jmri.23737] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2011] [Accepted: 05/21/2012] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To assess metabolite levels in peritumoral edematous (PO) and surrounding apparently normal (SAN) brain regions of glioblastoma, metastasis, and meningioma in humans with (1)H-MRSI to find biomarkers that can discriminate between tumors and characterize infiltrative tumor growth. MATERIALS AND METHODS Magnetic resonance (MR) spectra (semi-LASER MRSI, 30 msec echo time, 3T) were selected from regions of interest (ROIs) under MRI guidance, and after quality control of MR spectra. Statistical testing between patient groups was performed for mean metabolite ratios of an entire ROI and for the highest value within that ROI. RESULTS The highest ratios of the level of choline compounds and the sum of myo-inositol and glycine over N-acetylaspartate and creatine compounds were significantly increased in PO regions of glioblastoma versus that of metastasis and meningioma. In the SAN region of glioblastoma some of these ratios were increased. Differences were less prominent for metabolite levels averaged over entire ROIs. CONCLUSION Specific metabolite ratios in PO and SAN regions can be used to discriminate glioblastoma from metastasis and meningioma. An analysis of these ratios averaged over entire ROIs and those with most abnormal values indicates that infiltrative tumor growth in glioblastoma is inhomogeneous and extends into the SAN region.
Collapse
Affiliation(s)
- J P Wijnen
- Department of Radiology, Radboud University Medical Centre Nijmegen, Nijmegen, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
21
|
Banerjee A, Ganji S, Hulsey K, Dimitrov I, Maher E, Ghose S, Tamminga C, Choi C. Measurement of glycine in gray and white matter in the human brain in vivo by 1H MRS at 7.0 T. Magn Reson Med 2012; 68:325-31. [PMID: 22693073 DOI: 10.1002/mrm.24368] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2012] [Revised: 05/14/2012] [Accepted: 05/16/2012] [Indexed: 01/07/2023]
Abstract
The concentration of glycine (Gly) was measured in gray matter (GM) and white matter (WM) in the human brain using single-voxel localized (1)H MRS at 7 T. A point-resolved spectroscopy sequence with echo time = 150 ms was used for measuring Gly levels in various regions of the frontal and occipital lobes in 11 healthy volunteers and one subject with a glioblastoma. The point-resolved spectroscopy spectra were analyzed with LCModel using basis functions generated from density matrix simulations that included the effects of volume localized radio-frequency and gradient pulses. The fraction of GM and white matter within the voxels was obtained from T(1)-weighted image segmentation. The metabolite concentrations within the voxels, estimated with respect to the GM + WM water concentrations, were fitted to a linear function of fractional GM content. The Gly concentrations in pure GM and white matter were estimated to be 1.1 and 0.1 mM, with 95% confidence intervals 1.0-1.2 and 0.0-0.2, respectively.
Collapse
Affiliation(s)
- Abhishek Banerjee
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | | | | | | | | | | | | | | |
Collapse
|
22
|
The neurochemical profile quantified by in vivo 1H NMR spectroscopy. Neuroimage 2012; 61:342-62. [DOI: 10.1016/j.neuroimage.2011.12.038] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Accepted: 12/15/2011] [Indexed: 12/13/2022] Open
|
23
|
das Neves Duarte JM, Kulak A, Gholam-Razaee MM, Cuenod M, Gruetter R, Do KQ. N-acetylcysteine normalizes neurochemical changes in the glutathione-deficient schizophrenia mouse model during development. Biol Psychiatry 2012; 71:1006-14. [PMID: 21945305 DOI: 10.1016/j.biopsych.2011.07.035] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Revised: 07/11/2011] [Accepted: 07/29/2011] [Indexed: 12/21/2022]
Abstract
BACKGROUND Glutathione (GSH) is the major cellular redox-regulator and antioxidant. Redox-imbalance due to genetically impaired GSH synthesis is among the risk factors for schizophrenia. Here we used a mouse model with chronic GSH deficit induced by knockout (KO) of the key GSH-synthesizing enzyme, glutamate-cysteine ligase modulatory subunit (GCLM). METHODS With high-resolution magnetic resonance spectroscopy at 14.1 T, we determined the neurochemical profile of GCLM-KO, heterozygous, and wild-type mice in anterior cortex throughout development in a longitudinal study design. RESULTS Chronic GSH deficit was accompanied by an elevation of glutamine (Gln), glutamate (Glu), Gln/Glu, N-acetylaspartate, myo-Inositol, lactate, and alanine. Changes were predominantly present at prepubertal ages (postnatal days 20 and 30). Treatment with N-acetylcysteine from gestation on normalized most neurochemical alterations to wild-type level. CONCLUSIONS Changes observed in GCLM-KO anterior cortex, notably the increase in Gln, Glu, and Gln/Glu, were similar to those reported in early schizophrenia, emphasizing the link between redox imbalance and the disease and validating the model. The data also highlight the prepubertal period as a sensitive time for redox-related neurochemical changes and demonstrate beneficial effects of early N-acetylcysteine treatment. Moreover, the data demonstrate the translational value of magnetic resonance spectroscopy to study brain disease in preclinical models.
Collapse
Affiliation(s)
- Joao Miguel das Neves Duarte
- Laboratory for Functional and Metabolic Imaging, Center for Biomedical Imaging, Ecole Polytechnique Federale, University Hospital Lausanne, Switzerland.
| | | | | | | | | | | |
Collapse
|
24
|
Moser E, Stahlberg F, Ladd ME, Trattnig S. 7-T MR--from research to clinical applications? NMR IN BIOMEDICINE 2012; 25:695-716. [PMID: 22102481 DOI: 10.1002/nbm.1794] [Citation(s) in RCA: 143] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2010] [Revised: 08/25/2011] [Accepted: 08/31/2011] [Indexed: 05/31/2023]
Abstract
Over 20,000 MR systems are currently installed worldwide and, although the majority operate at magnetic fields of 1.5 T and below (i.e. about 70%), experience with 3-T (in high-field clinical diagnostic imaging and research) and 7-T (research only) human MR scanners points to a future in functional and metabolic MR diagnostics. Complementary to previous studies, this review attempts to provide an overview of ultrahigh-field MR research with special emphasis on emerging clinical applications at 7 T. We provide a short summary of the technical development and the current status of installed MR systems. The advantages and challenges of ultrahigh-field MRI and MRS are discussed with special emphasis on radiofrequency inhomogeneity, relaxation times, signal-to-noise improvements, susceptibility effects, chemical shifts, specific absorption rate and other safety issues. In terms of applications, we focus on the topics most likely to gain significantly from 7-T MR, i.e. brain imaging and spectroscopy and musculoskeletal imaging, but also body imaging, which is particularly challenging. Examples are given to demonstrate the advantages of susceptibility-weighted imaging, time-of-flight MR angiography, high-resolution functional MRI, (1)H and (31)P MRSI in the human brain, sodium and functional imaging of cartilage and the first results (and artefacts) using an eight-channel body array, suggesting future areas of research that should be intensified in order to fully explore the potential of 7-T MR systems for use in clinical diagnosis.
Collapse
Affiliation(s)
- Ewald Moser
- Centre for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
| | | | | | | |
Collapse
|
25
|
Fuchs A, Luttje M, Boesiger P, Henning A. SPECIAL semi-LASER with lipid artifact compensation for 1H MRS at 7 T. Magn Reson Med 2012; 69:603-12. [PMID: 22517487 DOI: 10.1002/mrm.24292] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2011] [Revised: 03/19/2012] [Accepted: 03/21/2012] [Indexed: 11/06/2022]
Abstract
The measurement of full metabolic profiles at ultrahigh fields including low concentrated or fast-relaxing metabolites is usually achieved by applying short echo time sequences. One sequence beside stimulated echo acquisition mode that was proposed in this regard is spin echo full intensity-acquired localized spectroscopy. Typical problems that are still persistent for spin echo full intensity-acquired localized spectroscopy are B(1) inhomogeneities especially for signal acquisition with surface coils and chemical shift displacement artifacts due to limited B(1) amplitudes when using volume coils. In addition, strong lipid contaminations in the final spectrum can occur when only a limited number of outer volume suppression pulses is used. Therefore, an adiabatic short echo time (= 19 ms) spin echo full intensity-acquired localized spectroscopy semilocalization by adiabatic selective refocusing sequence is presented that is less sensitive to strong B(1) variations and that offers increased excitation and refocusing pulse bandwidths than regular spin echo full intensity acquired localized spectroscopy. Furthermore, the existence of the systematic lipid artifact is identified and linked to unfavorable effects due to the preinversion localization pulse. A method to control this artifact is presented and validated in both phantom and in vivo measurements. The viability of the proposed sequence was further assessed for in vivo measurements by scanning 17 volunteers using a surface coil and moreover acquiring additional volume coil measurements. The results show well-suppressed lipid artifacts, good signal-to-noise ratio, and reproducible fitting results in accordance with other published studies.
Collapse
Affiliation(s)
- Alexander Fuchs
- Department of Information Technology and Electrical Engineering, Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.
| | | | | | | |
Collapse
|
26
|
Emir UE, Auerbach EJ, Van De Moortele PF, Marjańska M, Uğurbil K, Terpstra M, Tkáč I, Oz G. Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming. NMR IN BIOMEDICINE 2012; 25:152-60. [PMID: 21766380 PMCID: PMC3197892 DOI: 10.1002/nbm.1727] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2010] [Revised: 02/23/2011] [Accepted: 03/18/2011] [Indexed: 05/04/2023]
Abstract
Increased sensitivity and chemical shift dispersion at ultra-high magnetic fields enable the precise quantification of an extended range of brain metabolites from (1)H MRS. However, all previous neurochemical profiling studies using single-voxel MRS at 7 T have been limited to data acquired from the occipital lobe with half-volume coils. The challenges of (1)H MRS of the human brain at 7 T include short T(2) and complex B(1) distribution that imposes limitations on the maximum achievable B(1) strength. In this study, the feasibility of acquiring and quantifying short-echo (TE =8 ms), single-voxel (1)H MR spectra from multiple brain regions was demonstrated by utilizing a 16-channel transceiver array coil with 16 independent transmit channels, allowing local transmit B(1) (B(1)(+)) shimming. Spectra were acquired from volumes of interest of 1-8 mL in brain regions that are of interest for various neurological disorders: frontal white matter, posterior cingulate, putamen, substantia nigra, pons and cerebellar vermis. Local B(1)(+) shimming substantially increased the transmit efficiency, especially in the peripheral and ventral brain regions. By optimizing a STEAM sequence for utilization with a 16-channel coil, artifact-free spectra were acquired with a small chemical shift displacement error (<5% /ppm/direction) from all regions. The high signal-to-noise ratio enabled the quantification of neurochemical profiles consisting of at least nine metabolites, including γ-aminobutyric acid, glutamate and glutathione, in all brain regions. Significant differences in neurochemical profiles were observed between brain regions. For example, γ-aminobutyric acid levels were highest in the substantia nigra, total creatine was highest in the cerebellar vermis and total choline was highest in the pons, consistent with the known biochemistry of these regions. These findings demonstrate that single-voxel (1)H MRS at ultra-high field can reliably detect region-specific neurochemical patterns in the human brain, and has the potential to objectively detect alterations in neurochemical profiles associated with neurological diseases.
Collapse
Affiliation(s)
- Uzay E Emir
- Center for Magnetic Resonance Research, Department of Radiology, School of Medicine, University of Minnesota, Minneapolis, MN 55455, USA.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Terpstra M, Torkelson C, Emir U, Hodges JS, Raatz S. Noninvasive quantification of human brain antioxidant concentrations after an intravenous bolus of vitamin C. NMR IN BIOMEDICINE 2011; 24:521-8. [PMID: 21674654 PMCID: PMC3335753 DOI: 10.1002/nbm.1619] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Revised: 07/19/2010] [Accepted: 08/14/2010] [Indexed: 05/14/2023]
Abstract
Until now, the lack of a means to detect a deficiency or to measure the pharmacologic effect in the human brain in situ has been a hindrance to the development of antioxidant-based prevention and treatment of dementia. In this study, a recently developed (1) H MRS approach was applied to quantify key human brain antioxidant concentrations throughout the course of an aggressive antioxidant-based intervention. The concentrations of the two most abundant central nervous system chemical antioxidants, vitamin C and glutathione, were quantified noninvasively in the human occipital cortex prior to and throughout 24 h after bolus intravenous delivery of 3 g of vitamin C. Although the kinetics of the sodium-dependent vitamin C transporter and physiologic blood vitamin C concentrations predict theoretically that brain vitamin C concentration will not increase above its homeostatically maintained level, this theory has never been tested experimentally in the living human brain. Therefore, human brain vitamin C and glutathione concentrations were quantified noninvasively using MEGA-PRESS double-edited (1) H MRS and LCModel. Healthy subjects (age, 19-63 years) with typical dietary consumption, who did not take vitamin supplements, fasted overnight and then reported for the measurement of baseline antioxidant concentrations. They then began controlled feeding which they adhered to until after vitamin C and glutathione concentrations had been measured at 2, 6, 10 and 24 h after receiving intravenous vitamin C. Two of the twelve studies were sham controls in which no vitamin C was administered. The main finding was that human brain vitamin C and glutathione concentrations remained constant throughout the protocol, even though blood serum vitamin C concentrations spanned from the low end of the normal range to very high.
Collapse
Affiliation(s)
- Melissa Terpstra
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
| | | | | | | | | |
Collapse
|
28
|
Cerebral magnetic resonance spectroscopy at 7 Tesla: standard values and regional differences. Acad Radiol 2011; 18:584-7. [PMID: 21377907 DOI: 10.1016/j.acra.2010.12.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2010] [Revised: 11/29/2010] [Accepted: 12/16/2010] [Indexed: 12/27/2022]
Abstract
RATIONALE AND OBJECTIVES At lower magnetic field strengths, regional differences of cerebral metabolite distributions have been described, but these data are controversial. Magnetic resonance spectroscopy at 7 T is expected to deliver high spectral resolution and good differentiation, but there are problems arising at high magnetic field strengths that may diminish spectral quality. Because there have been only a few studies in humans so far, there are no standard values for 7 T concerning regional metabolite distributions and concentrations. MATERIALS AND METHODS In the present study, the metabolites detectable with (1)H magnetic resonance spectroscopy, N-acetyl-aspartate, choline, and creatine (Cr), were evaluated with a single-voxel sequence. Five voxels were placed in the frontal and parietal white matter and the insular, thalamic, and occipital gray matter. RESULTS For N-acetyl-aspartate, the lowest values were found in frontal white matter and the highest in thalamic gray matter. Choline displayed the lowest values in frontal white matter and the highest in insular gray matter. Cr showed the lowest values in frontal white matter and the highest in thalamic gray matter. The highest ratio of choline to Cr was found in parietal white matter and the lowest in thalamic gray matter. The highest ratio of N-acetyl-aspartate to Cr was found in thalamic gray matter and the lowest in frontal white matter. CONCLUSIONS In the present study, regional cerebral metabolite differences were verified with high-field magnetic resonance spectroscopy. Quantitative values and metabolite ratios could be a basis for further clinical studies.
Collapse
|
29
|
Choi C, Ganji SK, DeBerardinis RJ, Dimitrov IE, Pascual JM, Bachoo R, Mickey BE, Malloy CR, Maher EA. Measurement of glycine in the human brain in vivo by 1H-MRS at 3 T: application in brain tumors. Magn Reson Med 2011; 66:609-18. [PMID: 21394775 DOI: 10.1002/mrm.22857] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2010] [Revised: 12/21/2010] [Accepted: 01/10/2011] [Indexed: 01/27/2023]
Abstract
Glycine is a key metabolic intermediate required for the synthesis of proteins, nucleic acids, and other molecules, and its detection in cancer could, therefore, provide biologically relevant information about the growth of the tumor. Here, we report measurement of glycine in human brain and gliomas by an optimized point-resolved spectroscopy sequence at 3 T. Echo time dependence of the major obstacle, myo-inositol (mI) multiplet, was investigated with numerical simulations, incorporating the 3D volume localization. The simulations indicated that a subecho pair (TE(1) , TE(2) ) = (60, 100) ms permits detection of both glycine and mI with optimum selectivity. In vivo validation of the optimized point-resolved spectroscopy was conducted on the right parietal cortex of five healthy volunteers. Metabolite signals estimated from LC Model were normalized with respect to the brain water signal, and the concentrations were evaluated assuming the total creatine concentration at 8 mM. The glycine concentration was estimated as 0.6 ± 0.1 mM (mean ± SD, n = 5), with a mean Cramér-Rao lower bound of 9 ± 1%. The point-resolved spectroscopy sequence was applied to measure the glycine levels in patients with glioblastoma multiforme. Metabolite concentrations were obtained using the water signal from the tumor mass. The study revealed that a subset of human gliomas contains glycine levels elevated 1.5-8 fold relative to normal.
Collapse
Affiliation(s)
- Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Faria A, Macedo Jr. F, Marsaioli A, Ferreira M, Cendes F. Classification of brain tumor extracts by high resolution ¹H MRS using partial least squares discriminant analysis. Braz J Med Biol Res 2011; 44:149-64. [DOI: 10.1590/s0100-879x2010007500146] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2009] [Accepted: 11/17/2010] [Indexed: 11/22/2022] Open
Affiliation(s)
- A.V. Faria
- Universidade Estadual de Campinas; The Johns Hopkins University, USA
| | - F.C. Macedo Jr.
- Universidade Estadual de Campinas, Brasil; Universidade Estadual de Londrina, Brasil
| | | | | | - F. Cendes
- Universidade Estadual de Campinas, Brasil
| |
Collapse
|
31
|
Choi C, Dimitrov IE, Douglas D, Patel A, Kaiser LG, Amezcua CA, Maher EA. Improvement of resolution for brain coupled metabolites by optimized (1)H MRS at 7T. NMR IN BIOMEDICINE 2010; 23:1044-1052. [PMID: 20963800 DOI: 10.1002/nbm.1529] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Resolution enhancement for glutamate (Glu), glutamine (Gln) and glutathione (GSH) in the human brain by TE-optimized point-resolved spectroscopy (PRESS) at 7 T is reported. Sub-TE dependences of the multiplets of Glu, Gln, GSH, γ-aminobutyric acid (GABA) and N-acetylaspartate (NAA) at 2.2-2.6 ppm were investigated with density matrix simulations, incorporating three-dimensional volume localization. The numerical simulations indicated that the C4-proton multiplets can be completely separated with (TE(1), TE(2)) = (37, 63) ms, as a result of a narrowing of the multiplets and suppression of the NAA 2.5 ppm signal. Phantom experiments reproduced the signal yield and lineshape from simulations within experimental errors. In vivo tests of optimized PRESS were conducted on the prefrontal cortex of six healthy volunteers. In spectral fitting by LCModel, Cramér-Rao lower bounds (CRLBs) of Glu, Gln and GSH were 2 ± 1, 5 ± 1 and 6 ± 2 (mean ± SD), respectively. To evaluate the performance of the optimized PRESS method under identical experimental conditions, stimulated-echo spectra were acquired with (TE, TM) = (14, 37) and (74, 68) ms. The CRLB of Glu was similar between PRESS and short-TE stimulated-echo acquisition mode (STEAM), but the CRLBs of Gln and GSH were lower in PRESS than in both STEAM acquisitions.
Collapse
Affiliation(s)
- Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA.
| | | | | | | | | | | | | |
Collapse
|
32
|
Xin L, Gambarota G, Duarte JMN, Mlynárik V, Gruetter R. Direct in vivo measurement of glycine and the neurochemical profile in the rat medulla oblongata. NMR IN BIOMEDICINE 2010; 23:1097-1102. [PMID: 20963803 DOI: 10.1002/nbm.1537] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
The medulla oblongata (MO) contains a high density of glycinergic synapses and a particularly high concentration of glycine. The aims of this study were to measure directly in vivo the neurochemical profile, including glycine, in MO using a spin-echo-based (1)H MRS sequence at TE = 2.8 ms and to compare it with three other brain regions (cortex, striatum and hippocampus) in the rat. Glycine was quantified in MO at TE = 2.8 ms with a Cramér-Rao lower bound (CRLB) of approximately 5%. As a result of the relatively low level of glycine in the other three regions, the measurement of glycine was performed at TE = 20 ms, which provides a favorable J-modulation of overlapping myo-inositol resonance. The other 14 metabolites composing the neurochemical profile were quantified in vivo in MO with CRLBs below 25%. Absolute concentrations of metabolites in MO, such as glutamate, glutamine, γ-aminobutyrate, taurine and glycine, were in the range of previous in vitro quantifications in tissue extracts. Compared with the other regions, MO had a three-fold higher glycine concentration, and was characterised by reduced (p < 0.001) concentrations of glutamate (-50 ± 4%), glutamine (-54 ± 3%) and taurine (-78 ± 3%). This study suggests that the functional specialisation of distinct brain regions is reflected in the neurochemical profile.
Collapse
Affiliation(s)
- Lijing Xin
- Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
| | | | | | | | | |
Collapse
|
33
|
Righi V, Andronesi OC, Mintzopoulos D, Black PM, Tzika AA. High-resolution magic angle spinning magnetic resonance spectroscopy detects glycine as a biomarker in brain tumors. Int J Oncol 2010; 36:301-6. [PMID: 20043062 PMCID: PMC3715372 DOI: 10.3892/ijo_00000500] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The non-essential amino acid neurotransmitter glycine (Gly) may serve as a biomarker for brain tumors. Using 36 biopsies from patients with brain tumors [12 glioblastoma multiforme (GBM); 10 low-grade (LG), including 7 schwannoma and 3 pylocytic astrocytoma; 7 meningioma (MN); 7 brain metastases (MT), including 3 adenocarcinoma and 4 breast cancer] and 9 control biopsies from patients undergoing surgery for epilepsy, we tested the hypothesis that the presence of glycine may distinguish among these brain tumor types. Using high-resolution magic angle spinning (HRMAS) 1H magnetic resonance spectroscopy (MRS), we determined a theoretically optimum echo time (TE) of 50 ms for distinguishing Gly signals from overlapping myo-inositol (Myo) signals and tested our methodology in phantom and biopsy specimens. Quantitative analysis revealed higher levels of Gly in tumor biopsies (all combined) relative to controls; Gly levels were significantly elevated in LG, MT and GBM biopsies (P≤0.05). Residual Myo levels were elevated in LG and MT and reduced in MN and GBM (P<0.05 vs. control levels). We observed higher levels of Gly in GBM as compared to LG tumors (P=0.05). Meanwhile, although Gly levels in GBM and MT did not differ significantly from each other, the Gly:Myo ratio did distinguish GBM from MT (P<0.003) and from all other groups, a distinction that has not been adequately made previously. We conclude from these findings that Gly can serve as a biomarker for brain tumors and that the Gly:Myo ratio may be a useful index for brain tumor classification.
Collapse
Affiliation(s)
- Valeria Righi
- NMR Surgical Laboratory, Department of Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA 02114, USA
| | | | | | | | | |
Collapse
|
34
|
High-dose glycine treatment of refractory obsessive-compulsive disorder and body dysmorphic disorder in a 5-year period. Neural Plast 2010; 2009:768398. [PMID: 20182547 PMCID: PMC2825652 DOI: 10.1155/2009/768398] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Revised: 08/12/2009] [Accepted: 12/04/2009] [Indexed: 12/17/2022] Open
Abstract
This paper describes an individual who was diagnosed with obsessive-compulsive disorder (OCD) and body dysmorphic disorder (BDD) at age 17 when education was discontinued. By age 19, he was housebound without social contacts except for parents. Adequate trials of three selective serotonin reuptake inhibitors, two with atypical neuroleptics, were ineffective. Major exacerbations following ear infections involving Group A β-hemolytic streptococcus at ages 19 and 20 led to intravenous immune globulin therapy, which was also ineffective. At age 22, another severe exacerbation followed antibiotic treatment for H. pylori. This led to a hypothesis that postulates deficient signal transduction by the N-methyl-D-aspartate receptor (NMDAR). Treatment with glycine, an NMDAR coagonist, over 5 years led to robust reduction of OCD/BDD signs and symptoms except for partial relapses during treatment cessation. Education and social life were resumed and evidence suggests improved cognition. Our findings motivate further study of glycine treatment of OCD and BDD.
Collapse
|
35
|
Webb AG, Collins CM, Versluis MJ, Kan HE, Smith NB. MRI and localized proton spectroscopy in human leg muscle at 7 Tesla using longitudinal traveling waves. Magn Reson Med 2010; 63:297-302. [PMID: 20099323 PMCID: PMC2846515 DOI: 10.1002/mrm.22262] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2009] [Accepted: 09/30/2009] [Indexed: 11/08/2022]
Abstract
Using a small resonant loop to produce a longitudinal traveling wave on a human 7-T system allows MR to be performed over the entire volume of the human leg. We have used this capability to perform localized proton MR spectroscopy of the lipid composition of muscle in volunteers with a coil placed approximately 30 cm away from the region of interest. Spectra with a reasonable signal-to-noise ratio can be acquired in a clinically relevant data acquisition time of less than 5 min using the loop in transmit/receive mode, maintaining the full flexibility to acquire spectra from any part of the calf and/or thigh. If a local receive coil is used in combination with the remote transmit coil, then the signal-to-noise improves significantly, as expected.
Collapse
Affiliation(s)
- Andrew G Webb
- C.J.Gorter Center for High Field Magnetic Resonance Imaging, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.
| | | | | | | | | |
Collapse
|
36
|
Choi C, Douglas D, Hawesa H, Jindal A, Storey C, Dimitrov I. Measurement of glycine in human prefrontal brain by point-resolved spectroscopy at 7.0 tesla in vivo. Magn Reson Med 2010; 62:1305-10. [PMID: 19780175 DOI: 10.1002/mrm.22125] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Measurement of glycine in human frontal brain by an optimized point-resolved spectroscopy sequence at 7 T is reported. Echo time dependencies of the overlapping coupled resonances of myo-inositol, free choline, and threonine were investigated with density matrix simulations, incorporating the slice-selective radiofrequency and gradient pulses. The numerical simulations indicated that the selectivity of the 3.55-ppm glycine singlet is maximized at (TE(1), TE(2)) = (101, 51) ms. Phantom experiments indicated that the myo-inositol peak amplitude between 3.5 and 3.6 ppm is reduced by a factor of 30 following the optimized point-resolved spectroscopy, as predicted by the simulation. From LCModel analyses, the glycine concentration in the medial prefrontal cortex in healthy adults was estimated, with a mean Cramér-Rao lower bound of 7 +/- 1% (mean +/- standard deviation; n = 7), to be 0.8 +/- 0.1 mM, with reference to total creatine at 8 mM.
Collapse
Affiliation(s)
- Changho Choi
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390, USA.
| | | | | | | | | | | |
Collapse
|
37
|
Davies NP, Wilson M, Natarajan K, Sun Y, MacPherson L, Brundler MA, Arvanitis TN, Grundy RG, Peet AC. Non-invasive detection of glycine as a biomarker of malignancy in childhood brain tumours using in-vivo 1H MRS at 1.5 tesla confirmed by ex-vivo high-resolution magic-angle spinning NMR. NMR IN BIOMEDICINE 2010; 23:80-87. [PMID: 19795380 DOI: 10.1002/nbm.1432] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Management of brain tumours in children would benefit from improved non-invasive diagnosis, characterisation and prognostic biomarkers. Metabolite profiles derived from in-vivo MRS have been shown to provide such information. Studies indicate that using optimum a priori information on metabolite contents in the construction of linear combination (LC) models of MR spectra leads to improved metabolite profile estimation. Glycine (Gly) is usually neglected in such models due to strong overlap with myo-inositol (mI) and a low concentration in normal brain. However, biological studies indicate that Gly is abundant in high-grade brain tumours. This study aimed to investigate the quantitation of Gly in paediatric brain tumours using MRS analysed by LCModel, and its potential as a non-invasive biomarker of malignancy. Single-voxel MRS was performed using PRESS (TR 1500 ms, TE 30 ms/135 ms) on a 1.5 T scanner. Forty-seven cases (18 high grade (HG), 17 low grade (LG), 12 ungraded) were retrospectively selected if both short-TE and long-TE MRS (n = 33) or short-TE MRS and high-resolution magic-angle spinning (HRMAS) of matched surgical samples (n = 15) were available. The inclusion of Gly in LCModel analyses led to significantly reduced fit residues for both short-TE and long-TE MRS (p < 0.05). The Gly concentrations estimated from short-TE MRS were significantly correlated with the long-TE values (R = 0.91, p < 0.001). The Gly concentration estimated by LCModel was significantly higher in HG versus LG tumours for both short-TE (p < 1e-6) and long-TE (p = 0.003) MRS. This was consistent with the HRMAS results, which showed a significantly higher normalised Gly concentration in HG tumours (p < 0.05) and a significant correlation with the normalised Gly concentration measured from short-TE in-vivo MRS (p < 0.05). This study suggests that glycine can be reliably detected in paediatric brain tumours using in-vivo MRS on standard clinical scanners and that it is a promising biomarker of tumour aggressiveness.
Collapse
Affiliation(s)
- N P Davies
- Cancer Sciences, University of Birmingham, Birmingham, UK.
| | | | | | | | | | | | | | | | | |
Collapse
|