1
|
Khairallah S, Rahouma M, Gambardella I, Habib R, Gaudino M, Girardi L, Mick SL. Trends in the Management of Anterior Mitral Leaflet Regurgitation. JAMA Netw Open 2024; 7:e246726. [PMID: 38619838 PMCID: PMC11019396 DOI: 10.1001/jamanetworkopen.2024.6726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 02/17/2024] [Indexed: 04/16/2024] Open
Abstract
Importance The overall prevalence of mitral valve replacement (MVR) or MV repair at the time of cardiac surgery in the setting of isolated anterior mitral leaflet degenerative pathologic status in the US population is unknown. Objective To investigate the prevalence of MVR and MV repair using the Society of Thoracic Surgeons' Adult Cardiac Surgery Database. Design, Setting, and Participants In a cross-sectional study, all patients diagnosed with isolated anterior mitral leaflet degenerative regurgitation who underwent either surgical MVR or MV repair between July 1, 2011, and June 30, 2022, were identified. Linear regression analysis was used to assess trends over time. Main Outcomes and Measures Assessment of the trends in MV repair and MVR over time. Results A total of 16 259 patients (9624 [59.2%] men) were identified, and the median age was 68 (IQR, 58-74) years. A total of 7214 patients (44.4%) had MVR, and 9045 (55.6%) had MV repair. There was a declining trend of MV repair from 58.0% in 2011 to 51.6% in 2022 (P = .05). The MVR group was older (median [IQR] age, 70 [62-77] vs 67 [58-74] years; P < .001) and had more comorbidities. A total of 85.1% of all patients underwent concomitant procedures. In 81.7% of MVR cases, no attempt at MV repair was made. The median (IQR) annual hospital volume was lower with MVR vs MV repair (2.50 [1.50-5.00] vs 4.00 [2.00-7.00]; P < .001). Conventional surgical approaches were most common (91.5%) but with a declining trend (P < .001). Minimally invasive approaches were used in 13.1% (robotic, 4.6%), and with an inclining trend from 5.0% in 2011 to 12.0% in 2022 (P < .001). Annuloplasty was performed in 88.8% of MV repair cases. Its use as a sole mean of MV repair decreased from 48.0% in 2011 to 13.9% in 2022 (P < .001). Repair maneuvers in addition to annuloplasty were neochordae (overall 40.1%, increasing from 22.5% in 2011 to 62.3% in 2022; P < .001), leaflet resection (overall 10.2%, decreasing from 13.1% in 2011 to 7.9% in 2022, P = .002), edge-to-edge MV repair (overall 5.3%, decreasing from 6.9% in 2011 to 4.5% in 2022; P = 0.04), and chordal transfer (overall 2.4%, decreasing from 2.7% in 2011 to 0.7% in 2022; P = .004). Conclusions and Relevance In this cross-sectional study, MV repair was the preferred option for degenerative mitral valve disease but was only slightly more commonly performed than MVR for isolated anterior leaflet pathologic status. A large proportion of MVR was performed without an MV repair attempt, suggesting reluctance to repair this pathologic condition.
Collapse
Affiliation(s)
- Sherif Khairallah
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York
- National Cancer Institute, Cairo University, Cairo, Egypt
| | - Mohamed Rahouma
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York
- National Cancer Institute, Cairo University, Cairo, Egypt
| | | | - Robert Habib
- Society of Thoracic Surgeons Research Center, Chicago, Illinois
| | - Mario Gaudino
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York
| | - Leonard Girardi
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York
| | - Stephanie L. Mick
- Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, New York
| |
Collapse
|
2
|
Feng X, Liu Y, Kamensky D, McComb DW, Breuer CK, Sacks MS. Functional mechanical behavior of the murine pulmonary heart valve. Sci Rep 2023; 13:12852. [PMID: 37553466 PMCID: PMC10409802 DOI: 10.1038/s41598-023-40158-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 08/05/2023] [Indexed: 08/10/2023] Open
Abstract
Genetically modified mouse models provide a versatile and efficient platform to extend our understanding of the underlying disease processes and evaluate potential treatments for congenital heart valve diseases. However, applications have been limited to the gene and molecular levels due to the small size of murine heart valves, which prohibits the use of standard mechanical evaluation and in vivo imaging methods. We have developed an integrated imaging/computational mechanics approach to evaluate, for the first time, the functional mechanical behavior of the murine pulmonary heart valve (mPV). We utilized extant mPV high resolution µCT images of 1-year-old healthy C57BL/6J mice, with mPVs loaded to 0, 10, 20 or 30 mmHg then chemically fixed to preserve their shape. Individual mPV leaflets and annular boundaries were segmented and key geometric quantities of interest defined and quantified. The resulting observed inter-valve variations were small and consistent at each TVP level. This allowed us to develop a high fidelity NURBS-based geometric model. From the resultant individual mPV geometries, we developed a mPV shape-evolving geometric model (SEGM) that accurately represented mPV shape changes as a continuous function of transvalvular pressure. The SEGM was then integrated into an isogeometric finite element based inverse model that estimated the individual leaflet and regional mPV mechanical behaviors. We demonstrated that the mPV leaflet mechanical behaviors were highly anisotropic and nonlinear, with substantial leaflet and regional variations. We also observed the presence of strong axial mechanical coupling, suggesting the important role of the underlying collagen fiber architecture in the mPV. When compared to larger mammalian species, the mPV exhibited substantially different mechanical behaviors. Thus, while qualitatively similar, the mPV exhibited important functional differences that will need to accounted for in murine heart valve studies. The results of this novel study will allow detailed murine tissue and organ level investigations of semi-lunar heart valve diseases.
Collapse
Affiliation(s)
- Xinzeng Feng
- Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, 78712, USA
| | - Yifei Liu
- Center for Electron Microscopy and Analysis, The Ohio State University, Columbus, OH, 43210, USA
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - David Kamensky
- Department of Mechanical and Aerospace Engineering, University of California San Diego, San Diego, CA, 92093, USA
| | - David W McComb
- Center for Electron Microscopy and Analysis, The Ohio State University, Columbus, OH, 43210, USA
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Christopher K Breuer
- Center for Regenerative Medicine, Abigail Wexner Research Institute, Nationwide Children's Hospital, Columbus, OH, 43205, USA
- Department of Pediatric Surgery, Nationwide Children's Hospital, Columbus, OH, 43205, USA
| | - Michael S Sacks
- Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, 78712, USA.
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA.
| |
Collapse
|
3
|
Khairallah S, Rahouma M, Dabsha A, Demetres M, Gaudino MF, Mick SL. Comparison of meta-analytical estimates of outcomes after Alfieri or neochordal repair in isolated anterior mitral prolapse. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY : OFFICIAL JOURNAL OF THE EUROPEAN ASSOCIATION FOR CARDIO-THORACIC SURGERY 2023; 63:6984718. [PMID: 36629477 DOI: 10.1093/ejcts/ezac587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 12/07/2022] [Accepted: 01/10/2023] [Indexed: 01/12/2023]
Abstract
OBJECTIVES Repair of the isolated degenerative anterior mitral leaflet has been considered more challenging and associated with compromised durability compared with isolated posterior leaflet in major series. Implantation of neochordae or Alfieri edge-to-edge is the most employed repair technique for isolated anterior repair currently, but little data exist comparing their relative durability. We sought to investigate this issue with this meta-analysis. METHODS A literature search was performed (Ovid MEDLINE, Ovid Embase and The Cochrane Library). The primary outcome was the incidence rate (IR) of reoperation, the secondary outcomes were recurrent moderately severe/severe mitral regurgitation (MR), in-hospital/30-day reoperation and mortality and follow-up mortality. A random-effect model was used. Leave-one-out, subgroup analysis (Alfieri versus neochordae) and meta-regression were done. RESULTS Seventeen studies (including 1358 patients) were included. At a weighted mean follow-up of 5.56 ± 3.31 years, the IR for reoperation was 14.45 event per 1000 person-year and significantly lower in Alfieri than neochordae repair (9.40 vs 18.61, P = 0.04) on subgroup analysis. The IR of follow-up moderately severe/severe MR was 19.89 event per 1000 person-year and significantly lower in Alfieri than neochordae repair (10.68 and 28.63, P = 0.01). In a sensitivity analysis comparing homogenous studies, a significant difference in the recurrence of regurgitation in favour of the Alfieri approach remained. There were no differences in operative outcomes or survival. There were significant associations between increased incidence of late reoperation and New York Heart Association class III/IV and associated coronary artery bypass graft procedure for whole cohort. CONCLUSIONS Alfieri repair may be associated with a lower incidence of recurrent MR compared with neochordae-based repair in the setting of isolated degenerative anterior mitral pathology. This is the first such meta-analysis and further inquiry into this area is needed.
Collapse
Affiliation(s)
- Sherif Khairallah
- Cardiothoracic Surgery Department, Weill Cornell Medicine New York-Presbyterian Hospital (WCM), New York, NY, USA
| | - Mohamed Rahouma
- Cardiothoracic Surgery Department, Weill Cornell Medicine New York-Presbyterian Hospital (WCM), New York, NY, USA
| | - Anas Dabsha
- Cardiothoracic Surgery Department, Weill Cornell Medicine New York-Presbyterian Hospital (WCM), New York, NY, USA
| | - Michelle Demetres
- Scholarly Communications Librarian, Weill Cornell Medicine (WCM), Samuel J. Wood Library & C.V. Starr Biomedical Information Center, New York, NY, USA
| | - Mario Fl Gaudino
- Cardiothoracic Surgery Department, Weill Cornell Medicine New York-Presbyterian Hospital (WCM), New York, NY, USA
| | - Stephanie L Mick
- Cardiothoracic Surgery Department, Weill Cornell Medicine New York-Presbyterian Hospital (WCM), New York, NY, USA
| |
Collapse
|
4
|
Rego BV, Khalighi AH, Gorman JH, Gorman RC, Sacks MS. Simulation of Mitral Valve Plasticity in Response to Myocardial Infarction. Ann Biomed Eng 2023; 51:71-87. [PMID: 36030332 DOI: 10.1007/s10439-022-03043-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 08/01/2022] [Indexed: 01/13/2023]
Abstract
Left ventricular myocardial infarction (MI) has broad and debilitating effects on cardiac function. In many cases, MI leads to ischemic mitral regurgitation (IMR), a condition characterized by incompetency of the mitral valve (MV). IMR has many deleterious effects as well as a high mortality rate. While various clinical treatments for IMR exist, success of these procedures remains limited, in large part because IMR dramatically alters the geometry and function of the MV in ways that are currently not well understood. Previous investigations of post-MI MV remodeling have elucidated that MV tissues have a significant ability to undergo a form of permanent inelastic deformations in the first phase of the post-MI period. These changes appear to be attributable to the altered loading and boundary conditions on the MV itself, as opposed to an independent pathophysiological process. Mechanistically, these results suggest that the MV mostly responds passively to MI during the first 8 weeks post-MI by undergoing a permanent deformation. In the present study, we developed the first computational model of this post-MI MV remodeling process, which we term "mitral valve plasticity." Integrating methodologies and insights from previous studies of in vivo ovine MV function, image-based patient-specific model development, and post-MI MV adaptation, we constructed a representative geometric model of a pre-MI MV. We then performed finite element simulations of the entire MV apparatus under time-dependent boundary conditions and accounting for changes to material properties equivalent to those observed 0-8 weeks post-MI. Our results suggest that during this initial period of adaptation, the MV response to MI can be accurately modeled using a soft tissue plasticity approach, similar to permanent set frameworks that have been applied previously in the context of exogenously crosslinked tissues.
Collapse
Affiliation(s)
- Bruno V Rego
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Amir H Khalighi
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Joseph H Gorman
- Gorman Cardiovascular Research Group, Smilow Center for Translational Research, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Robert C Gorman
- Gorman Cardiovascular Research Group, Smilow Center for Translational Research, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Michael S Sacks
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
5
|
Nian G, Kim J, Bao X, Suo Z. Making Highly Elastic and Tough Hydrogels from Doughs. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2206577. [PMID: 36126085 DOI: 10.1002/adma.202206577] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 09/11/2022] [Indexed: 06/15/2023]
Abstract
A hydrogel is often fabricated from preexisting polymer chains by covalently crosslinking them into a polymer network. The crosslinks make the hydrogel swell-resistant but brittle. This conflict is resolved here by making a hydrogel from a dough. The dough is formed by mixing long polymer chains with a small amount of water and photoinitiator. The dough is then homogenized by kneading and annealing at elevated temperatures, during which the crowded polymer chains densely entangle. The polymer chains are then sparsely crosslinked into a polymer network under an ultraviolet lamp, and submerged in water to swell to equilibrium. The resulting hydrogel is both swell-resistant and tough. The hydrogel also has near-perfect elasticity, high strength, high fatigue resistance, and low friction. The method is demonstrated with two widely used polymers, poly(ethylene glycol) and cellulose. These hydrogels have never been made swell-resistant, elastic, and tough before. The method is generally applicable to synthetic and natural polymers, and is compatible with industrial processing technologies, opening doors to the development of sustainable, high-performance hydrogels.
Collapse
Affiliation(s)
- Guodong Nian
- John A. Paulson School of Engineering and Applied Sciences, Kavli Institute for Bionano Science and Technology, Harvard University, Cambridge, MA, 02138, USA
| | - Junsoo Kim
- John A. Paulson School of Engineering and Applied Sciences, Kavli Institute for Bionano Science and Technology, Harvard University, Cambridge, MA, 02138, USA
| | - Xianyang Bao
- John A. Paulson School of Engineering and Applied Sciences, Kavli Institute for Bionano Science and Technology, Harvard University, Cambridge, MA, 02138, USA
- Centre for Polymer from Renewable Resource, SFSE, South China University of Technology, Guangzhou, 510640, China
| | - Zhigang Suo
- John A. Paulson School of Engineering and Applied Sciences, Kavli Institute for Bionano Science and Technology, Harvard University, Cambridge, MA, 02138, USA
| |
Collapse
|
6
|
Wang B, Sierad LN, Mercuri JJ, Simionescu A, Simionescu DT, Williams LN, Vela R, Bajona P, Peltz M, Ramaswamy S, Hong Y, Liao J. Structural and biomechanical characterizations of acellular porcine mitral valve scaffolds: anterior leaflets, posterior leaflets, and chordae tendineae. ENGINEERED REGENERATION 2022; 3:374-386. [PMID: 38362305 PMCID: PMC10869114 DOI: 10.1016/j.engreg.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Mitral valve (MV) tissue engineering is still in its early stage, and one major challenge in MV tissue engineering is to identify appropriate scaffold materials. With the potential of acellular MV scaffolds being demonstrated recently, it is important to have a full understanding of the biomechanics of the native MV components and their acellular scaffolds. In this study, we have successfully characterized the structural and mechanical properties of porcine MV components, including anterior leaflet (AL), posterior leaflet (PL), strut chordae, and basal chordae, before and after decellularization. Quantitative DNA assay showed more than 90% reduction in DNA content, and Griffonia simplicifolia (GS) lectin immunohistochemistry confirmed the complete lack of porcine α-Gal antigen in the acellular MV components. In the acellular AL and PL, the atrialis, spongiosa, and fibrosa trilayered structure, along with its ECM constitutes, i.e., collagen fibers, elastin fibers, and portion of GAGs, were preserved. Nevertheless, the ECM of both AL and PL experienced a certain degree of disruption, exhibiting a less dense, porous ECM morphology. The overall anatomical morphology of the strut and basal chordae were also maintained after decellularization, with longitudinal morphology experiencing minimum disruption, but the cross-sectional morphology exhibiting evenly-distributed porous structure. In the acellular AL and PL, the nonlinear anisotropic biaxial mechanical behavior was overall preserved; however, uniaxial tensile tests showed that the removal of cellular content and the disruption of structural ECM did result in small decreases in maximum tensile modulus, tissue extensibility, failure stress, and failure strain for both MV leaflets and chordae.
Collapse
Affiliation(s)
- Bo Wang
- Joint Department of Biomedical Engineering, Medical College of Wisconsin and Marquette University, Milwaukee, WI 53226, United States
| | - Leslie N. Sierad
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Jeremy J. Mercuri
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Agneta Simionescu
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Dan T. Simionescu
- Department of Bioengineering, Clemson University, Clemson, SC 29634, United States
| | - Lakiesha N. Williams
- Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611, United States
| | - Ryan Vela
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
| | - Pietro Bajona
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
- Allegheny Health Network-Drexel University College of Medicine, Pittsburgh, PA 15212, United States
| | - Matthias Peltz
- Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States
| | - Sharan Ramaswamy
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, United States
| | - Yi Hong
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76010, United States
| | - Jun Liao
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76010, United States
| |
Collapse
|
7
|
Fitzpatrick DJ, Pham K, Ross CJ, Hudson LT, Laurence DW, Yu Y, Lee CH. Ex vivo experimental characterizations for understanding the interrelationship between tissue mechanics and collagen microstructure of porcine mitral valve leaflets. J Mech Behav Biomed Mater 2022; 134:105401. [DOI: 10.1016/j.jmbbm.2022.105401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 07/18/2022] [Accepted: 07/24/2022] [Indexed: 12/13/2022]
|
8
|
Vandemaele P, Vander Linden K, Deferm S, Jashari R, Rega F, Bertrand P, Vandervoort P, Vander Sloten J, Famaey N, Fehervary H. Alterations in Human Mitral Valve Mechanical Properties Secondary to Left Ventricular Remodeling: A Biaxial Mechanical Study. Front Cardiovasc Med 2022; 9:876006. [PMID: 35811738 PMCID: PMC9258718 DOI: 10.3389/fcvm.2022.876006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 04/11/2022] [Indexed: 11/18/2022] Open
Abstract
Secondary mitral regurgitation occurs when a left ventricular problem causes leaking of the mitral valve. The altered left ventricular geometry changes the orientation of the subvalvular apparatus, thereby affecting the mechanical stress on the mitral valve. This in turn leads to active remodeling of the mitral valve, in order to compensate for the ventricular remodeling. In this study, a biomechanical analysis was performed on eight human mitral valves with secondary mitral regurgitation and ten healthy human mitral valves to better understand this pathophysiology and its effect on the mechanical properties of these tissues. Samples were obtained from the anterior and posterior leaflet and used for planar biaxial mechanical experiments. Uniaxial experiments were performed on four groups of mitral valve chords: anterior basal, anterior marginal, posterior basal and posterior marginal chords. The mechanical response of the mitral valve leaflets was fitted to the May-Newman and Yin constitutive model, whereas the material parameters of the third order Ogden model were determined for the chord samples. Next, stiffnesses calculated at low and high stress levels were statistically analyzed. Leaflet samples with secondary mitral regurgitation showed a small thickness increase and a change in anisotropy index compared to healthy control valves. Diseased leaflets were more compliant circumferentially and stiffer radially, resulting in anisotropic samples with the radial direction being stiffest. In addition, chord samples were slightly thicker and less stiff at high stress in secondary mitral regurgitation, when grouped per leaflet type and insertion region. These results confirm mechanical alterations due to the pathophysiological valvular changes caused by left ventricular remodeling. It is important that these changes in mechanical behavior are incorporated into computational models of the mitral valve.
Collapse
Affiliation(s)
- Paulien Vandemaele
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Klaas Vander Linden
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Sébastien Deferm
- Cardiology, Hospital Oost-Limburg, Genk, Belgium
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Ramadan Jashari
- European Homograft Bank, Clinic Saint-Jean, Brussels, Belgium
| | - Filip Rega
- Cardiac Surgery, University Hospitals Leuven, Leuven, Belgium
| | | | - Pieter Vandervoort
- Cardiology, Hospital Oost-Limburg, Genk, Belgium
- Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium
| | - Jos Vander Sloten
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Nele Famaey
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
- FIBEr, KU Leuven, Leuven, Belgium
| | - Heleen Fehervary
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
- FIBEr, KU Leuven, Leuven, Belgium
- *Correspondence: Heleen Fehervary
| |
Collapse
|
9
|
Lee N, Shi L, Colon Caraballo M, Nallasamy S, Mahendroo M, Myers K. Mechanical Response of Mouse Cervices Lacking Decorin and Biglycan During Pregnancy. J Biomech Eng 2022; 144:1139857. [PMID: 35348624 DOI: 10.1115/1.4054199] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Indexed: 11/08/2022]
Abstract
Cervical remodeling is critical for a healthy pregnancy. The proper regulation of extracellular matrix (ECM) turnover leads to remodeling throughout gestation, transforming the tissue from a stiff material to a compliant, extensible, viscoelastic tissue prepared for delivery. Small leucine rich proteoglycans (SLRPs) are known to regulate structural fiber assembly in the cervical ECM and overall tissue material properties. To quantify the SLRPs' mechanical role in the cervix, whole cervix specimens from non-pregnant and late pregnant knockout mice of SLRPs, decorin and biglycan, were subjected to cyclic load-unload, ramp-hold, and load-to-failure mechanical tests. Further, a fiber composite material model, accounting for collagen fiber bundle waviness, was developed to describe the three-dimensional large deformation equilibrium behavior of the cervix. In nonpregnant tissue, SLRP KO cervices have the same equilibrium material properties as wild-type tissue. In contrast, the load-to-failure and ramp-hold tests reveal SLRPs impact rupture and time-dependent relaxation behavior. Loss of decorin in NP cervices results in inferior rupture properties. While remodeling recovers cervical strength, the SLRP-deficient tissue has diminished ability to dissipate stress during a ramp-hold. In mice with a combined loss of decorin and biglycan, the pregnant cervix loses its extensibility, compliance, and viscoelasticity. Taken together, these results suggest decorin and biglycan are necessary for key compliance and viscoelastic material property features of a healthy remodeled pregnant cervix.
Collapse
Affiliation(s)
- Nicole Lee
- Department of Mechanical Engineering, Columbia University, New York, New York
| | - Lei Shi
- Department of Mechanical Engineering, Columbia University, New York, New York
| | - Mariano Colon Caraballo
- Department of Obstetrics and Gynecology, Cecil H. and Ida Green Center for Reproductive Biological Science, The University of Texas, Southwestern Medical Center, Dallas, Texas
| | - Shanmugasundaram Nallasamy
- Department of Obstetrics and Gynecology, Cecil H. and Ida Green Center for Reproductive Biological Science, The University of Texas, Southwestern Medical Center, Dallas, Texas
| | - Mala Mahendroo
- Department of Obstetrics and Gynecology, Cecil H. and Ida Green Center for Reproductive Biological Science, The University of Texas, Southwestern Medical Center, Dallas, Texas
| | - Kristin Myers
- Department of Mechanical Engineering, Columbia University, New York, New York
| |
Collapse
|
10
|
Dover CM, Goth W, Goodbrake C, Tunnell JW, Sacks MS. Simultaneous Wide-Field Planar Strain-Fiber Orientation Distribution Measurement Using Polarized Spatial Domain Imaging. Ann Biomed Eng 2022; 50:253-277. [PMID: 35084627 DOI: 10.1007/s10439-021-02889-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 11/04/2021] [Indexed: 11/26/2022]
Abstract
In the present study, we demonstrate that soft tissue fiber architectural maps captured using polarized spatial frequency domain imaging (pSFDI) can be utilized as an effective texture source for DIC-based planar surface strain analyses. Experimental planar biaxial mechanical studies were conducted using pericardium as the exemplar tissue, with simultaneous pSFDI measurements taken. From these measurements, the collagen fiber preferred direction [Formula: see text] was determined at the pixel level over the entire strain range using established methods ( https://doi.org/10.1007/s10439-019-02233-0 ). We then utilized these pixel-level [Formula: see text] maps as a texture source to quantify the deformation gradient tensor [Formula: see text] as a function of spatial position [Formula: see text] within the specimen at time t. Results indicted that that the pSFDI approach produced accurate deformation maps, as validated using both physical markers and conventional particle based method derived from the DIC analysis of the same specimens. We then extended the pSFDI technique to extract the fiber orientation distribution [Formula: see text] as a function of [Formula: see text] from the pSFDI intensity signal. This was accomplished by developing a calibration procedure to account for the optical behavior of the constituent fibers for the soft tissue being studied. We then demonstrated that the extracted [Formula: see text] was accurately computed in both the referential (i.e. unloaded) and deformed states. Moreover, we noted that the measured [Formula: see text] agreed well with affine kinematic deformation predictions. We also demonstrated this calibration approach could also be effectively used on electrospun biomaterials, underscoring the general utility of the approach. In a final step, using the ability to simultaneously quantify [Formula: see text] and [Formula: see text], we examined the effect of deformation and collagen structural measurements on the measurement region size. For pericardial tissues, we determined a critical length of [Formula: see text] 8 mm wherein the regional variations sufficiently dissipated. This result has immediate potential in the identification of optimal length scales for meso-scale strain measurement in soft tissues and fibrous biomaterials.
Collapse
Affiliation(s)
- Coinneach Mackenzie Dover
- James T. Willerson Center for Cardiovascular Modeling and Simulation, The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
| | - Will Goth
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Christian Goodbrake
- James T. Willerson Center for Cardiovascular Modeling and Simulation, The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
| | - James W Tunnell
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Michael S Sacks
- James T. Willerson Center for Cardiovascular Modeling and Simulation, The Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA.
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
11
|
Ross CJ, Laurence DW, Echols AL, Babu AR, Gu T, Duginski GA, Johns CH, Mullins BT, Casey KM, Laurence KA, Zhao YD, Amini R, Fung KM, Mir A, Burkhart HM, Wu Y, Holzapfel GA, Lee CH. Effects of enzyme-based removal of collagen and elastin constituents on the biaxial mechanical responses of porcine atrioventricular heart valve anterior leaflets. Acta Biomater 2021; 135:425-440. [PMID: 34481053 DOI: 10.1016/j.actbio.2021.08.043] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 08/22/2021] [Accepted: 08/26/2021] [Indexed: 12/24/2022]
Abstract
The leaflets of the atrioventricular heart valves (AHVs) regulate the one-directional flow of blood through a coordination of the extracellular matrix components, including the collagen fibers, elastin, and glycosaminoglycans. Dysfunction of the AHVs, such as those caused by unfavorable microstructural remodeling, lead to valvular heart diseases and improper blood flow, which can ultimately cause heart failure. In order to better understand the mechanics and remodeling of the AHV leaflets and how therapeutics can inadvertently cause adverse microstructural changes, a systematic characterization of the role of each constituent in the biomechanical properties is appropriate. Previous studies have quantified the contributions of the individual microstructural components to tissue-level behavior for the semilunar valve cusps, but not for the AHV leaflets. In this study, for the first time, we quantify the relationships between microstructure and mechanics of the AHV leaflet using a three-step experimental procedure: (i) biaxial tension and stress relaxation testing of control (untreated) porcine AHV anterior leaflet specimens; (ii) enzyme treatment to remove a portion of either the collagen or elastin constituent; and (iii) biaxial tensile and stress relaxation testing of the constituent-removed (treated) specimens. We have observed that the removal of ∼100% elastin resulted in a ∼10% decrease in the tissue extensibility with biaxial tension and a ∼10% increase in the overall stress reduction with stress relaxation. In contrast, removal of 46% of the collagen content insignificantly affected tissue extensibility with biaxial tension and significantly increased stress decay (10%) with stress relaxation. These findings provide an insight into the microstructure-mechanics relationship of the AHVs and will be beneficial for future developments and refinements of microstructurally informed constitutive models for the simulation of diseased and surgically intervened AHV function. STATEMENT OF SIGNIFICANCE: This study presents, for the first time, a thorough mechanical characterization of the atrioventricular heart valve leaflets before and after enzymatic removal of elastin and collagen. We found that the biaxial tensile properties of elastin-deficient tissues and collagen-deficient are stiffer. The fact of elastin supporting low-stress valve function and collagen as the main load-bearing component was evident in a decrease in the low-tension modulus for elastin-deficient tissues and in the high-tension modulus for collagen-deficient tissues. Our quantification and experimental technique could be useful in predicting the disease-related changes in heart valve mechanics. The information obtained from this work is valuable for refining the constitutive models that describe the essential microstructure-mechanics relationship.
Collapse
|
12
|
Adventures in Heart Valve Function A Personal Thank You to Dr. Ajit P. Yoganathan. Cardiovasc Eng Technol 2021; 12:651-653. [PMID: 34145557 DOI: 10.1007/s13239-021-00555-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 06/07/2021] [Indexed: 01/19/2023]
|
13
|
Xu L, Yang F, Ge Y, Guo G, Wang Y. Crosslinking porcine aortic valve by radical polymerization for the preparation of BHVs with improved cytocompatibility, mild immune response, and reduced calcification. J Biomater Appl 2021; 35:1218-1232. [PMID: 33478311 DOI: 10.1177/0885328220984066] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Over one million artificial heart valve transplantations are performed each year due to valvular stenosis or regurgitation. Among them, bioprosthetic heart valves (BHVs) are increasingly being used because of the absence of the need for lifelong anticoagulation. Almost all of the commercial BHVs are treated with Glutaraldehyde (GLUT). As GLUT-treated BHVs are prone to calcification and structural degradation, their durability is greatly reduced with a service life of only 12-15 years. The physiological structure and mechanical properties of the porcine aortic valve (PAV) are closer to that of a human heart valve, so in this study, PAV is used as the model to explore the comprehensive properties of the prepared BHVs by radical polymerization crosslinking method. We found that PAV treated by radical polymerization crosslinking method showed similar ECM stability and biaxial mechanical properties with GLUT-treated PAV. However, radical polymerization crosslinked PAV exhibited better cytocompatibility and endothelialization potential in vitro cell experiment as better anticalcification potential and reduced immune response than GLUT-treated PAV through subcutaneous animal experiments in rats. To conclude, a novel crosslinking method of non-glutaraldehyde fixation of xenogeneic tissues for the preparation of BHVs is expected.
Collapse
Affiliation(s)
- Liangpeng Xu
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, PR China
| | - Fan Yang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, PR China
| | - Yao Ge
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, PR China
| | - Gaoyang Guo
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, PR China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, PR China
| |
Collapse
|
14
|
Biomechanical properties of acellular scar ECM during the acute to chronic stages of myocardial infarction. J Mech Behav Biomed Mater 2021; 116:104342. [PMID: 33516128 DOI: 10.1016/j.jmbbm.2021.104342] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 01/14/2021] [Accepted: 01/17/2021] [Indexed: 02/08/2023]
Abstract
After myocardial infarction (MI), the infarcted tissue undergoes dynamic and time-dependent changes. Previous knowledge on MI biomechanical alterations has been obtained by studying the explanted scar tissues. In this study, we decellularized MI scar tissue and characterized the biomechanics of the obtained pure scar ECM. By thoroughly removing the cellular content in the MI scar tissue, we were able to avoid its confounding effects. Rat MI hearts were obtained from a reliable and reproducible model based on permanent left coronary artery ligation (PLCAL). MI heart explants at various time points (15 min, 1 week, 2 weeks, 4 weeks, and 12 weeks) were subjected to decellularization with 0.1% sodium dodecyl sulfate solution for ~1-2 weeks to obtain acellular scar ECM. A biaxial mechanical testing system was used to characterize the acellular scar ECM under physiologically relevant loading conditions. After decellularization, large decrease in wall thickness was observed in the native heart ECM and 15 min scar ECM, implying the collapse of cardiomyocyte lacunae after removal of heart muscle fibers. For scar ECM 1 week, 2 weeks, and 4 weeks post infarction, the decrease in wall thickness after decellularization was small. For scar ECM 12 weeks post infarction, the reduction amount of wall thickness due to decellularization was minimal. We found that the scar ECM preserved the overall mechanical anisotropy of the native ventricle wall and MI scar tissue, in which the longitudinal direction is more extensible. Acellular scar ECM from 15 min to 12 weeks post infarction showed an overall stiffening trend in biaxial behavior, in which longitudinal direction was mostly affected and manifested with a decreased extensibility and increased modulus. This reduction trend of longitudinal extensibility also led to a decreased anisotropy index in the scar ECM from the acute to chronic stages of MI. The post-MI change in biomechanical properties of the scar ECM reflected the alterations of collagen fiber network, confirmed by the histology of scar ECM. In short, the reported structure-property relationship reveals how scar ECM biophysical properties evolve from the acute to chronic stages of MI. The obtained information will help establish a knowledge basis about the dynamics of scar ECM to better understand post-MI cardiac remodeling.
Collapse
|
15
|
Bender JM, Adams WR, Mahadevan-Jansen A, Merryman WD, Bersi MR. Radiofrequency ablation alters the microstructural organization of healthy and enzymatically digested porcine mitral valves. EXPERIMENTAL MECHANICS 2021; 61:235-251. [PMID: 33776074 PMCID: PMC7992362 DOI: 10.1007/s11340-020-00662-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 08/20/2020] [Accepted: 08/25/2020] [Indexed: 05/12/2023]
Abstract
BACKGROUND Myxomatous mitral valve degeneration is a common cause of mitral regurgitation and is often associated with mitral valve prolapse. With no known targets to pharmacologically treat mitral valve prolapse, surgery is often the only treatment option. Recently, radiofrequency ablation has been proposed as a percutaneous alternative to surgical resection for the reduction of mitral valve leaflet area. OBJECTIVE Using an in vitro model of porcine mitral valve anterior leaflet enlargement following enzymatic digestion, we sought to investigate mechanisms by which radiofrequency ablation alters the geometry, microstructural organization, and mechanical properties of healthy and digested leaflets. METHODS Paired measurements before and after ablation revealed the impact of radiofrequency ablation on leaflet properties. Multiphoton imaging was used to characterize changes in the structure and organization of the valvular extracellular matrix; planar biaxial mechanical testing and constitutive modeling were used to estimate mechanical properties of healthy and digested leaflets. RESULTS Enzymatic digestion increased leaflet area and thickness to a similar extent as clinical mitral valve disease. Radiofrequency ablation altered extracellular matrix alignment and reduced the area of digested leaflets to that of control. Additionally, enzymatic digestion resulted in fiber alignment and reorientation toward the radial direction, causing increased forces during ablation and a structural stiffening which was improved by radiofrequency ablation. CONCLUSION Radiofrequency ablation induces radial extracellular matrix alignment and effectively reduces the area of enlarged mitral valve leaflets. Hence, this technique may be a therapeutic approach for myxomatous mitral valve disease and is thus an avenue for future study.
Collapse
Affiliation(s)
- J M Bender
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - W R Adams
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - A Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - W D Merryman
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - M R Bersi
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
16
|
He Q, Laurence DW, Lee CH, Chen JS. Manifold learning based data-driven modeling for soft biological tissues. J Biomech 2020; 117:110124. [PMID: 33515902 DOI: 10.1016/j.jbiomech.2020.110124] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 07/16/2020] [Accepted: 11/03/2020] [Indexed: 02/08/2023]
Abstract
Data-driven modeling directly utilizes experimental data with machine learning techniques to predict a material's response without the necessity of using phenomenological constitutive models. Although data-driven modeling presents a promising new approach, it has yet to be extended to the modeling of large-deformation biological tissues. Herein, we extend our recent local convexity data-driven (LCDD) framework (He and Chen, 2020) to model the mechanical response of a porcine heart mitral valve posterior leaflet. The predictability of the LCDD framework by using various combinations of biaxial and pure shear training protocols are investigated, and its effectiveness is compared with a full structural, phenomenological model modified from Zhang et al. (2016) and a continuum phenomenological Fung-type model (Tong and Fung, 1976). We show that the predictivity of the proposed LCDD nonlinear solver is generally less sensitive to the type of loading protocols (biaxial and pure shear) used in the data set, while more sensitive to the insufficient coverage of the experimental data when compared to the predictivity of the two selected phenomenological models. While no pre-defined functional form in the material model is necessary in LCDD, this study reinstates the importance of having sufficiently rich data coverage in the date-driven and machine learning type of approaches. It is also shown that the proposed LCDD method is an enhancement over the earlier distance-minimization data-driven (DMDD) against noisy data. This study demonstrates that when sufficient data is available, data-driven computing can be an alternative method for modeling complex biological materials.
Collapse
Affiliation(s)
- Qizhi He
- Department of Structural Engineering, University of California, San Diego, La Jolla, CA 92093, USA; Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, WA 99354, USA
| | - Devin W Laurence
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, Norman, OK 73019, USA
| | - Jiun-Shyan Chen
- Department of Structural Engineering, University of California, San Diego, La Jolla, CA 92093, USA.
| |
Collapse
|
17
|
A versatile biaxial testing platform for soft tissues. J Mech Behav Biomed Mater 2020; 114:104144. [PMID: 33153924 DOI: 10.1016/j.jmbbm.2020.104144] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 09/02/2020] [Accepted: 10/14/2020] [Indexed: 11/20/2022]
Abstract
Uniaxial testing remains the most common modality of mechanical analysis for biological and other soft materials; however, biaxial testing enables a more comprehensive understanding of these materials' mechanical behavior. In recent years, a number of commercially available biaxial testing systems designed for biological materials have been produced; however, there are common limitations that are often associated with using these systems. For example, the range of allowable sample geometries are relatively constrained, the clamping systems are relatively limited with respect to allowable configurations, the load and displacement ranges are relatively small, and the software and control elements offer relatively limited options. Due to these constraints, there are significant benefits associated with designing custom biaxial testing systems that meet the technical requirements for testing a broad range of materials. Herein we present a design for a biaxial testing system with capabilities that extend beyond those associated with typical commercially available systems. Our design is capable of performing uniaxial tests, traditional biaxial tests, and double lap shear (simple shear) tests, in either a displacement or load control mode. Testing protocols have been developed and proof-of-concept experiments have been performed on commercially available silicone membranes and rat abdominal skin samples.
Collapse
|
18
|
Shi X, Liu Y, Copeland KM, McMahan SR, Zhang S, Butler JR, Hong Y, Cho M, Bajona P, Gao H, Liao J. Epicardial prestrained confinement and residual stresses: a newly observed heart ventricle confinement interface. J R Soc Interface 2020; 16:20190028. [PMID: 30862283 DOI: 10.1098/rsif.2019.0028] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The heart epicardial layer, with elastin as the dominant component, has not been well investigated, specifically on how it contributes to ventricular biomechanics. In this study, we revealed and quantitatively assessed the overall status of prestraining and residual stresses exerted by the epicardial layer on the heart left ventricle (LV). During porcine heart wall dissection, we discovered that bi-layered LV surface strips, consisting of an epicardial layer and cardiac muscle, always curled towards the epicardial side due to epicardial residual stresses. We hence developed a curling angle characterization technique to intuitively and qualitatively reveal the location-dependency and direction-dependency of epicardial residual stresses. Moreover, by combining prestrain measurement and biaxial mechanical testing, we were able to quantify the epicardial prestrains and residual stresses on the unpressurized intact LV. To investigate the potential mechanical effect of epicardial prestraining, a finite-element (FE) model has been constructed, and we demonstrate that it is the prestraining of the epicardial layer, not the epicardial layer alone, providing an additional resistance mechanism during LV diastolic expansion and ventricular wall protection by reducing myocardial stress. In short, our study on healthy, native porcine hearts has revealed an important phenomenon-the epicardial layer, rich in elastin, acts like a prestrained 'balloon' that wraps around the heart and functions as an extra confinement and protection interface. The obtained knowledge fills a gap in ventricular biomechanics and will help design novel biomimicking materials or prosthetic devices to target the maintenance/recreation of this ventricle confinement interface.
Collapse
Affiliation(s)
- Xiaodan Shi
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA.,3 Bagley College of Engineering, College of Veterinary Medicine, Mississippi State University , Mississippi State, MS 39762 , USA
| | - Yue Liu
- 2 School of Engineering, Brown University , Providence, RI 02912 , USA
| | - Katherine M Copeland
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA
| | - Sara R McMahan
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA
| | - Song Zhang
- 3 Bagley College of Engineering, College of Veterinary Medicine, Mississippi State University , Mississippi State, MS 39762 , USA
| | - J Ryan Butler
- 3 Bagley College of Engineering, College of Veterinary Medicine, Mississippi State University , Mississippi State, MS 39762 , USA
| | - Yi Hong
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA.,5 Joint Biomedical Engineering Graduate Program, University of Texas Southwestern Medical Center , Dallas, TX 75390 , USA
| | - Michael Cho
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA
| | - Pietro Bajona
- 4 Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center , Dallas, TX 75390 , USA.,5 Joint Biomedical Engineering Graduate Program, University of Texas Southwestern Medical Center , Dallas, TX 75390 , USA
| | - Huajian Gao
- 2 School of Engineering, Brown University , Providence, RI 02912 , USA
| | - Jun Liao
- 1 Department of Bioengineering, University of Texas at Arlington , Arlington, TX 76010 , USA.,5 Joint Biomedical Engineering Graduate Program, University of Texas Southwestern Medical Center , Dallas, TX 75390 , USA
| |
Collapse
|
19
|
Xu C, Okpokwasili C, Huang Y, Shi X, Wu J, Liao J, Tang L, Hong Y. Optimizing Anisotropic Polyurethane Scaffolds to Mechanically Match with Native Myocardium. ACS Biomater Sci Eng 2020; 6:2757-2769. [PMID: 33313394 PMCID: PMC7725265 DOI: 10.1021/acsbiomaterials.9b01860] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Biodegradable cardiac patch is desirable to possess mechanical properties mimicking native myocardium for heart infarction treatment. We fabricated a series of anisotropic and biodegradable polyurethane porous scaffolds via thermally induced phase separation (TIPS) and tailored their mechanical properties by using various polyurethanes with different soft segments and varying polymer concentrations. The uniaxial mechanical properties, suture retention strength, ball-burst strength, and biaxial mechanical properties of the anisotropic porous scaffolds were optimized to mechanically match native myocardium. The optimal anisotropic scaffold had a ball burst strength (20.7 ± 1.5 N) comparable to that of native porcine myocardium (20.4 ± 6.0 N) and showed anisotropic behavior close to biaxial stretching behavior of the native porcine myocardium. Furthermore, the optimized porous scaffold was combined with a porcine myocardium-derived hydrogel to form a biohybrid scaffold. The biohybrid scaffold showed morphologies similar to the decellularized porcine myocardial matrix. This combination did not affect the mechanical properties of the synthetic scaffold alone. After in vivo rat subcutaneous implantation, the biohybrid scaffolds showed minimal immune response and exhibited higher cell penetration than the polyurethane scaffold alone. This biohybrid scaffold with biomimetic mechanics and good tissue compatibility would have great potential to be applied as a biodegradable acellular cardiac patch for myocardial infarction treatment.
Collapse
Affiliation(s)
- Cancan Xu
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Chuka Okpokwasili
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Yihui Huang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Xiaodan Shi
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Jinglei Wu
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Jun Liao
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Liping Tang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Yi Hong
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX 76019, USA
- Joint Biomedical Engineering Program, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| |
Collapse
|
20
|
Howsmon DP, Rego BV, Castillero E, Ayoub S, Khalighi AH, Gorman RC, Gorman JH, Ferrari G, Sacks MS. Mitral valve leaflet response to ischaemic mitral regurgitation: from gene expression to tissue remodelling. J R Soc Interface 2020; 17:20200098. [PMID: 32370692 PMCID: PMC7276554 DOI: 10.1098/rsif.2020.0098] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 04/07/2020] [Indexed: 02/06/2023] Open
Abstract
Ischaemic mitral regurgitation (IMR), a frequent complication following myocardial infarction (MI), leads to higher mortality and poor clinical prognosis if untreated. Accumulating evidence suggests that mitral valve (MV) leaflets actively remodel post MI, and this remodelling increases both the severity of IMR and the occurrence of MV repair failures. However, the mechanisms of extracellular matrix maintenance and modulation by MV interstitial cells (MVICs) and their impact on MV leaflet tissue integrity and repair failure remain largely unknown. Herein, we sought to elucidate the multiscale behaviour of IMR-induced MV remodelling using an established ovine model. Leaflet tissue at eight weeks post MI exhibited significant permanent plastic radial deformation, eliminating mechanical anisotropy, accompanied by altered leaflet composition. Interestingly, no changes in effective collagen fibre modulus were observed, with MVICs slightly rounder, at eight weeks post MI. RNA sequencing indicated that YAP-induced genes were elevated at four weeks post MI, indicating elevated mechanotransduction. Genes related to extracellular matrix organization were downregulated at four weeks post MI when IMR occurred. Transcriptomic changes returned to baseline by eight weeks post MI. This multiscale study suggests that IMR induces plastic deformation of the MV with no functional damage to the collagen fibres, providing crucial information for computational simulations of the MV in IMR.
Collapse
Affiliation(s)
- Daniel P. Howsmon
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Bruno V. Rego
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Estibaliz Castillero
- Department of Surgery, Columbia University Irving Medical Center, New York, NY, USA
| | - Salma Ayoub
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Amir H. Khalighi
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Robert C. Gorman
- Gorman Cardiovascular Research Group, Smilow Center for Translational Research, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Joseph H. Gorman
- Gorman Cardiovascular Research Group, Smilow Center for Translational Research, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Giovanni Ferrari
- Department of Surgery, Columbia University Irving Medical Center, New York, NY, USA
| | - Michael S. Sacks
- James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences and the Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
21
|
Anssari-Benam A, Tseng YT, Holzapfel GA, Bucchi A. Rate-dependent mechanical behaviour of semilunar valves under biaxial deformation: From quasi-static to physiological loading rates. J Mech Behav Biomed Mater 2020; 104:103645. [PMID: 32174403 DOI: 10.1016/j.jmbbm.2020.103645] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 11/29/2022]
Abstract
In this study we investigate the rate-dependency of the mechanical behaviour of semilunar heart valves under biaxial deformation, from quasi-static to physiological loading rates. This work extends and complements our previous undertaking, where the rate-dependency in the mechanical behaviour of semilunar valve specimens was documented in sub-physiological rate domains (Acta Biomater. 2019; https://doi.org/10.1016/j.actbio.2019.02.008). For the first time we demonstrate herein that the stress-stretch curves obtained from specimens under physiological rates too are markedly different to those at sufficiently lower rates and at quasi-static conditions. The results importantly underline that the mechanical behaviour of semilunar heart valves is rate dependent, and the physiological mechanical behaviour of the valves may not be correctly obtained via material characterisation tests at arbitrary low deformation rates. Presented results in this work provide an inclusive dataset for material characterisation and modelling of semilunar heart valves across a 10,000 fold deformation rate, both under equi-biaxial and 1:3 ratio deformation rates. The important application of these results is to inform the development of appropriate mechanical testing protocols, as well as devising new models, for suitable determination of the rate-dependent constitutive mechanical behaviour of the semilunar valves.
Collapse
Affiliation(s)
- Afshin Anssari-Benam
- Cardiovascular Engineering Research Laboratory (CERL), School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Road, Portsmouth, PO1 3DJ, United Kingdom.
| | - Yuan-Tsan Tseng
- National Heart and Lung Institute, Heart Science Centre, Imperial College London, Middlesex, United Kingdom
| | - Gerhard A Holzapfel
- Graz University of Technology, Institute of Biomechanics, Graz, Austria; Norwegian University of Science and Technology (NTNU), Department of Structural Engineering, Trondheim, Norway
| | - Andrea Bucchi
- Cardiovascular Engineering Research Laboratory (CERL), School of Mechanical and Design Engineering, University of Portsmouth, Anglesea Road, Portsmouth, PO1 3DJ, United Kingdom
| |
Collapse
|
22
|
Jett SV, Hudson LT, Baumwart R, Bohnstedt BN, Mir A, Burkhart HM, Holzapfel GA, Wu Y, Lee CH. Integration of polarized spatial frequency domain imaging (pSFDI) with a biaxial mechanical testing system for quantification of load-dependent collagen architecture in soft collagenous tissues. Acta Biomater 2020; 102:149-168. [PMID: 31734412 PMCID: PMC8101699 DOI: 10.1016/j.actbio.2019.11.028] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 11/11/2019] [Accepted: 11/12/2019] [Indexed: 12/30/2022]
Abstract
Collagen fiber networks provide the structural strength of tissues, such as tendons, skin and arteries. Quantifying the fiber architecture in response to mechanical loads is essential towards a better understanding of the tissue-level mechanical behaviors, especially in assessing disease-driven functional changes. To enable novel investigations into these load-dependent fiber structures, a polarized spatial frequency domain imaging (pSFDI) device was developed and, for the first time, integrated with a biaxial mechanical testing system. The integrated instrument is capable of a wide-field quantification of the fiber orientation and the degree of optical anisotropy (DOA), representing the local degree of fiber alignment. The opto-mechanical instrument''s performance was assessed through uniaxial loading on tendon tissues with known collagen fiber microstructures. Our results revealed that the bulk fiber orientation angle of the tendon tissue changed minimally with loading (median ± 0.5*IQR of 52.7° ± 3.3° and 51.9° ± 3.3° under 0 and 3% longitudinal strains, respectively), whereas on a micro-scale, the fibers became better aligned with the direction of loading: the DOA (mean ± SD) increased from 0.149 ± 0.032 to 0.198 ± 0.056 under 0 and 3% longitudinal strains, respectively, p < 0.001. The integrated instrument was further applied to study two representative mitral valve anterior leaflet (MVAL) tissues subjected to various biaxial loads. The fiber orientations within these representative MVAL tissue specimens demonstrated noticeable heterogeneity, with the local fiber orientations dependent upon the sample, the spatial and transmural locations, and the applied loading. Our results also showed that fibers were generally better aligned under equibiaxial (DOA = 0.089 ± 0.036) and circumferentially-dominant loading (DOA = 0.086 ± 0.037) than under the radially-dominant loading (DOA = 0.077 ± 0.034), indicating circumferential predisposition. These novel findings exemplify a deeper understanding of the load-dependent collagen fiber microstructures obtained through the use of the integrated opto-mechanical instrument. STATEMENT OF SIGNIFICANCE: In this study, a novel quantitative opto-mechanical system was developed by combining a polarized Spatial Frequency Domain Imaging (pSFDI) device with a biaxial mechanical tester. The integrated system was used to quantify the load-dependent collagen fiber microstructures in representative tendon and mitral valve anterior leaflet (MVAL) tissues. Our results revealed that MVAL's fiber architectures exhibited load-dependent spatial and transmural heterogeneities, suggesting further microstructural complexity than previously reported in heart valve tissues. These novel findings were possible through the system's ability to, for the first time, capture the load-dependent collagen architecture in the mitral valve anterior leaflet tissue over a wide field of view (e.g., 10 × 10 mm for the MVAL tissue specimens). Such capabilities afford unique future opportunities to improve patient outcomes through concurrent mechanical and microstructural assessments of healthy and diseased tissues in conditions such as heart valve regurgitation and calcification.
Collapse
Affiliation(s)
- Samuel V Jett
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, Affiliated Faculty Member, Institute for Biomedical Engineering, Science, and Technology, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219C, Norman, OK 73019-3609, United States
| | - Luke T Hudson
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, Affiliated Faculty Member, Institute for Biomedical Engineering, Science, and Technology, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219C, Norman, OK 73019-3609, United States
| | - Ryan Baumwart
- Center for Veterinary Health Sciences, Oklahoma State University, 2065 W. Farm Rd., Stillwater, OK 74078, United States
| | - Bradley N Bohnstedt
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, 1000 N Lincoln Blvd #400, Oklahoma City, OK 73104, United States
| | - Arshid Mir
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Oklahoma Health Sciences Center, 1200 Children's Ave., Suite 2F, Oklahoma City, OK 73104, United States
| | - Harold M Burkhart
- Division of Cardiothoracic Surgery, Department of Surgery, The University of Oklahoma Health Sciences Center, 800 Stanton L. Young Blvd. Suite 9000, Oklahoma City, OK 73104, United States
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16/2 8010 Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, Affiliated Faculty Member, Institute for Biomedical Engineering, Science, and Technology, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219C, Norman, OK 73019-3609, United States
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, Affiliated Faculty Member, Institute for Biomedical Engineering, Science, and Technology, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219C, Norman, OK 73019-3609, United States; Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, 202 West Boyd St., Norman, OK 73019, United States.
| |
Collapse
|
23
|
Li RL, Russ J, Paschalides C, Ferrari G, Waisman H, Kysar JW, Kalfa D. Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing. Biomaterials 2019; 225:119493. [PMID: 31569017 PMCID: PMC6948849 DOI: 10.1016/j.biomaterials.2019.119493] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/21/2019] [Accepted: 09/11/2019] [Indexed: 01/12/2023]
Abstract
The native human heart valve leaflet contains a layered microstructure comprising a hierarchical arrangement of collagen, elastin, proteoglycans and various cell types. Here, we review the various experimental methods that have been employed to probe this intricate microstructure and which attempt to elucidate the mechanisms that govern the leaflet's mechanical properties. These methods include uniaxial, biaxial, and flexural tests, coupled with microstructural characterization techniques such as small angle X-ray scattering (SAXS), small angle light scattering (SALS), and polarized light microscopy. These experiments have revealed complex elastic and viscoelastic mechanisms that are highly directional and dependent upon loading conditions and biochemistry. Of all engineering materials, polymers and polymer-based composites are best able to mimic the tissue-level mechanical behavior of the native leaflet. This similarity to native tissue permits the fabrication of polymeric valves with physiological flow patterns, reducing the risk of thrombosis compared to mechanical valves and in some cases surpassing the in vivo durability of bioprosthetic valves. Earlier work on polymeric valves simply assumed the mechanical properties of the polymer material to be linear elastic, while more recent studies have considered the full hyperelastic stress-strain response. These material models have been incorporated into computational models for the optimization of valve geometry, with the goal of minimizing internal stresses and improving durability. The latter portion of this review recounts these developments in polymeric heart valves, with a focus on mechanical testing of polymers, valve geometry, and manufacturing methods.
Collapse
Affiliation(s)
- Richard L Li
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA; Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY, USA
| | - Jonathan Russ
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Costas Paschalides
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Giovanni Ferrari
- Department of Surgery and Biomedical Engineering, Columbia University Medical Center, New York, NY, USA
| | - Haim Waisman
- Department of Civil Engineering and Engineering Mechanics, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA
| | - Jeffrey W Kysar
- Department of Mechanical Engineering, Fu Foundation School of Engineering and Applied Science, Columbia University, New York, NY, USA; Department of Otolaryngology - Head and Neck Surgery, Columbia University Medical Center, New York, NY, USA.
| | - David Kalfa
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children's Hospital, Columbia University Medical Center, New York, NY, USA.
| |
Collapse
|
24
|
Taylor M, Shirani M, Dabiri Y, Guccione JM, Steigmann DJ. Finite elastic wrinkling deformations of incompressible fiber-reinforced plates. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE 2019; 144:10.1016/j.ijengsci.2019.103138. [PMID: 32063652 PMCID: PMC7020621 DOI: 10.1016/j.ijengsci.2019.103138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
A two-dimensional plate theory, valid for finite elastic deformations with small strains, is derived for incompressible, fiber-reinforced materials. Single-layer plates and two-layer laminates are considered. Numerical simulations illustrate the substantial effect that fiber reinforcement has on wrinkling patterns in the sheet.
Collapse
Affiliation(s)
- M. Taylor
- Department of Mechanical Engineering, Santa Clara University, Santa Clara, CA 95053 USA
| | - M. Shirani
- Department of Mechanical Engineering, University of California, Berkeley, CA 94720 USA
| | - Y. Dabiri
- Department of Surgery, University of California, San Francisco, CA 94143 USA
| | - J. M. Guccione
- Department of Surgery, University of California, San Francisco, CA 94143 USA
| | - D. J. Steigmann
- Department of Mechanical Engineering, University of California, Berkeley, CA 94720 USA
| |
Collapse
|
25
|
Khoiy KA, Pant AD, Amini R. Quantification of Material Constants for a Phenomenological Constitutive Model of Porcine Tricuspid Valve Leaflets for Simulation Applications. J Biomech Eng 2019; 140:2681002. [PMID: 29801174 DOI: 10.1115/1.4040126] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 11/08/2022]
Abstract
The tricuspid valve is a one-way valve on the pulmonary side of the heart, which prevents backflow of blood during ventricular contractions. Development of computational models of the tricuspid valve is important both in understanding the normal valvular function and in the development/improvement of surgical procedures and medical devices. A key step in the development of such models is quantification of the mechanical properties of the tricuspid valve leaflets. In this study, after examining previously measured five-loading-protocol biaxial stress-strain response of porcine tricuspid valves, a phenomenological constitutive framework was chosen to represent this response. The material constants were quantified for all three leaflets, which were shown to be highly anisotropic with average anisotropy indices of less than 0.5 (an anisotropy index value of 1 indicates a perfectly isotropic response, whereas a smaller value of the anisotropy index indicates an anisotropic response). To obtain mean values of material constants, stress-strain responses of the leaflet samples were averaged and then fitted to the constitutive model (average R2 over 0.9). Since the sample thicknesses were not hugely different, averaging the data using the same tension levels and stress levels produced similar average material constants for each leaflet.
Collapse
Affiliation(s)
- Keyvan Amini Khoiy
- Department of Biomedical Engineering, The University of Akron Olson Research Center, Room 322/3 260 South Forge Street, Akron, OH 44325 e-mail:
| | - Anup D Pant
- Department of Biomedical Engineering, The University of Akron Olson Research Center, Room 322/3 260 South Forge Street, Akron, OH 44325 e-mail:
| | - Rouzbeh Amini
- Mem. ASME Department of Biomedical Engineering, The University of Akron Olson Research Center, , Akron, OH 44325 e-mail:
| |
Collapse
|
26
|
Kramer KE, Ross CJ, Laurence DW, Babu AR, Wu Y, Towner RA, Mir A, Burkhart HM, Holzapfel GA, Lee CH. An investigation of layer-specific tissue biomechanics of porcine atrioventricular valve anterior leaflets. Acta Biomater 2019; 96:368-384. [PMID: 31260822 PMCID: PMC6717680 DOI: 10.1016/j.actbio.2019.06.049] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 06/24/2019] [Accepted: 06/26/2019] [Indexed: 12/29/2022]
Abstract
Atrioventricular heart valves (AHVs) are composed of structurally complex and morphologically heterogeneous leaflets. The coaptation of these leaflets during the cardiac cycle facilitates unidirectional blood flow. Valve regurgitation is treated preferably by surgical repair if possible or replacement based on the disease state of the valve tissue. A comprehensive understanding of valvular morphology and mechanical properties is crucial to refining computational models, serving as a patient-specific diagnostic and surgical tool for preoperative planning. Previous studies have modeled the stress distribution throughout the leaflet's thickness, but validations with layer-specific biaxial mechanical experiments are missing. In this study, we sought to fill this gap in literature by investigating the impact of microstructure constituents on mechanical behavior throughout the thickness of the AHVs' anterior leaflets. Porcine mitral valve anterior leaflets (MVAL) and tricuspid valve anterior leaflets (TVAL) were micro-dissected into three layers (atrialis/spongiosa, fibrosa, and ventricular) and two layers (atrialis/spongiosa and fibrosa/ventricularis), respectively, based on their relative distributions of extracellular matrix components as quantified by histological analyses: collagen, elastin, and glycosaminoglycans. Our results suggest that (i) for both valves, the atrialis/spongiosa layer is the most extensible and anisotropic layer, possibly due to its relatively low collagen content as compared to other layers, (ii) the intact TVAL response is stiffer than the atrialis/spongiosa layer but more compliant than the fibrosa/ventricularis layer, and (iii) the MVAL fibrosa and ventricularis layers behave nearly isotropic. These novel findings emphasize the biomechanical variances throughout the AHV leaflets, and our results could better inform future AHV computational model developments. STATEMENT OF SIGNIFICANCE: This study, which is the first of its kind for atrioventricular heart valve (AHV) leaflet tissue layers, rendered a mechanical characterization of the biaxial mechanical properties and distributions of extracellular matrix components (collagen, elastin, and glycosaminoglycans) of the mitral and tricuspid valve anterior leaflet layers. The novel findings from the present study emphasize the biomechanical variances throughout the thickness of AHV leaflets, and our results indicate that the previously-adopted homogenous leaflet in the AHV biomechanical modeling may be an oversimplification of the complex leaflet anatomy. Such improvement in the understanding of valvular morphology and tissue mechanics is crucial to future refinement of AHV computational models, serving as a patient-specific diagnostic and surgical tool, at the preoperative stage, for treating valvular heart diseases.
Collapse
Affiliation(s)
- Katherine E Kramer
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Colton J Ross
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Devin W Laurence
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Anju R Babu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Rheal A Towner
- Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation, Oklahoma City, OK 73104, USA
| | - Arshid Mir
- Division of Pediatric Cardiology, Department of Pediatrics, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Harold M Burkhart
- Division of Cardiothoracic Surgery, Department of Surgery, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, Norman, OK 73019, USA.
| |
Collapse
|
27
|
Vekilov DP, Singh M, Aglyamov SR, Larin KV, Grande-Allen KJ. Mapping the spatial variation of mitral valve elastic properties using air-pulse optical coherence elastography. J Biomech 2019; 93:52-59. [PMID: 31300156 PMCID: PMC10575695 DOI: 10.1016/j.jbiomech.2019.06.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 05/18/2019] [Accepted: 06/14/2019] [Indexed: 10/26/2022]
Abstract
The mitral valve is a highly heterogeneous tissue composed of two leaflets, anterior and posterior, whose unique composition and regional differences in material properties are essential to overall valve function. While mitral valve mechanics have been studied for many decades, traditional testing methods limit the spatial resolution of measurements and can be destructive. Optical coherence elastography (OCE) is an emerging method for measuring viscoelastic properties of tissues in a noninvasive, nondestructive manner. In this study, we employed air-pulse OCE to measure the spatial variation in mitral valve elastic properties with micro-scale resolution at 1 mm increments along the radial length of the leaflets. We analyzed differences between the leaflets, as well as between regions of the valve. We found that the anterior leaflet has a higher elastic wave velocity, which is reported as a surrogate for stiffness, than the posterior leaflet, most notably at the annular edge of the sample. In addition, we found a spatial elastic gradient in the anterior leaflet, where the annular edge was found to have a greater elastic wave velocity than the free edge. This gradient was less pronounced in the posterior leaflet. These patterns were confirmed using established uniaxial tensile testing methods. Overall, the anterior leaflet was stiffer and had greater heterogeneity in its mechanical properties than the posterior leaflet. This study measures differences between the two mitral leaflets with greater resolution than previously feasible and demonstrates a method that may be suitable for assessing valve mechanics following repair or during the engineering of synthetic valve replacements.
Collapse
Affiliation(s)
| | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering, Houston, TX, United States
| | - Salavat R Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, TX, United States; University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, United States
| | - Kirill V Larin
- University of Houston, Department of Biomedical Engineering, Houston, TX, United States
| | | |
Collapse
|
28
|
Thomas VS, Lai V, Amini R. A computational multi-scale approach to investigate mechanically-induced changes in tricuspid valve anterior leaflet microstructure. Acta Biomater 2019; 94:524-535. [PMID: 31229629 DOI: 10.1016/j.actbio.2019.05.074] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 05/10/2019] [Accepted: 05/16/2019] [Indexed: 12/12/2022]
Abstract
The tricuspid valve is an atrioventricular valve that prevents blood backflow from the right ventricle into the right atrium during ventricular contractions. It is important to study mechanically induced microstructural alterations in the tricuspid valve leaflets, as this aids both in understanding valvular diseases and in the development of new engineered tissue replacements. The structure and composition of the extracellular matrix (ECM) fiber networks are closely tied to an overall biomechanical function of the tricuspid valve. In this study, we conducted experiments and implemented a multiscale modeling approach to predict ECM microstructural changes to tissue-level mechanical responses in a controlled loading environment. In particular, we characterized a sample of a porcine anterior leaflet at a macroscale using a biaxial mechanical testing method. We then generated a three-dimensional finite element model, to which computational representations of corresponding fiber networks were incorporated based on properties of the microstructural architecture obtained from small angle light scattering. Using five different biaxial boundary conditions, we performed iterative simulations to obtain model parameters with an overall R2 value of 0.93. We observed that mechanical loading could markedly alter the underlying ECM architecture. For example, a relatively isotropic fiber network (with an anisotropy index value α of 28%) became noticeably more anisotropic (with an α of 40%) when it underwent mechanical loading. We also observed that the mechanical strain was distributed in a different manner at the ECM/fiber level as compared to the tissue level. The approach presented in this study has the potential to be implemented in pathophysiologically altered biomechanical and structural conditions and to bring insights into the mechanobiology of the tricuspid valve. STATEMENT OF SIGNIFICANCE: Quantifying abnormal cellar/ECM-level deformation of tricuspid valve leaflets subjected to a modified loading environment is of great importance, as it is believed to be linked to valvular remodeling responses. For example, developing surgical procedures or engineered tissue replacements that maintain/mimic ECM-level mechanical homeostasis could lead to more durable outcomes. To quantify leaflet deformation, we built a multiscale framework encompassing the contributions of disorganized ECM components and organized fibers, which can predict the behavior of the tricuspid valve leaflets under physiological loading conditions both at the tissue level and at the ECM level. In addition to future in-depth studies of tricuspid valve pathologies, our model can be used to characterize tissues in other valves of the heart.
Collapse
|
29
|
Ross CJ, Laurence DW, Richardson J, Babu AR, Evans LE, Beyer EG, Childers RC, Wu Y, Towner RA, Fung KM, Mir A, Burkhart HM, Holzapfel GA, Lee CH. An investigation of the glycosaminoglycan contribution to biaxial mechanical behaviours of porcine atrioventricular heart valve leaflets. J R Soc Interface 2019; 16:20190069. [PMID: 31266416 PMCID: PMC6685018 DOI: 10.1098/rsif.2019.0069] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Accepted: 06/03/2019] [Indexed: 01/06/2023] Open
Abstract
The atrioventricular heart valve (AHV) leaflets have a complex microstructure composed of four distinct layers: atrialis, ventricularis, fibrosa and spongiosa. Specifically, the spongiosa layer is primarily proteoglycans and glycosaminoglycans (GAGs). Quantification of the GAGs' mechanical contribution to the overall leaflet function has been of recent focus for aortic valve leaflets, but this characterization has not been reported for the AHV leaflets. This study seeks to expand current GAG literature through novel mechanical characterizations of GAGs in AHV leaflets. For this characterization, mitral and tricuspid valve anterior leaflets (MVAL and TVAL, respectively) were: (i) tested by biaxial mechanical loading at varying loading ratios and by stress-relaxation procedures, (ii) enzymatically treated for removal of the GAGs and (iii) biaxially mechanically tested again under the same protocols as in step (i). Removal of the GAG contents from the leaflet was conducted using a 100 min enzyme treatment to achieve approximate 74.87% and 61.24% reductions of all GAGs from the MVAL and TVAL, respectively. Our main findings demonstrated that biaxial mechanical testing yielded a statistically significant difference in tissue extensibility after GAG removal and that stress-relaxation testing revealed a statistically significant smaller stress decay of the enzyme-treated tissue than untreated tissues. These novel findings illustrate the importance of GAGs in AHV leaflet behaviour, which can be employed to better inform heart valve therapeutics and computational models.
Collapse
Affiliation(s)
- Colton J. Ross
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Devin W. Laurence
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Jacob Richardson
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Anju R. Babu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Lauren E. Evans
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Ean G. Beyer
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Rachel C. Childers
- Stephenson School of Biomedical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Rheal A. Towner
- Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation, Oklahoma City, OK, USA
| | - Kar-Ming Fung
- Department of Pathology, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
- Stephenson Cancer Center, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Arshid Mir
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Harold M. Burkhart
- Division of Cardiothoracic Surgery, Department of Surgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Gerhard A. Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
- Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, Norman, OK, USA
| |
Collapse
|
30
|
Ross C, Laurence D, Wu Y, Lee CH. Biaxial Mechanical Characterizations of Atrioventricular Heart Valves. J Vis Exp 2019. [PMID: 31033941 PMCID: PMC8008701 DOI: 10.3791/59170] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Extensive biaxial mechanical testing of the atrioventricular heart valve leaflets can be utilized to derive optimal parameters used in constitutive models, which provide a mathematical representation of the mechanical function of those structures. This presented biaxial mechanical testing protocol involves (i) tissue acquisition, (ii) the preparation of tissue specimens, (iii) biaxial mechanical testing, and (iv) postprocessing of the acquired data. First, tissue acquisition requires obtaining porcine or ovine hearts from a local Food and Drug Administration-approved abattoir for later dissection to retrieve the valve leaflets. Second, tissue preparation requires using tissue specimen cutters on the leaflet tissue to extract a clear zone for testing. Third, biaxial mechanical testing of the leaflet specimen requires the use of a commercial biaxial mechanical tester, which consists of force-controlled, displacement-controlled, and stress-relaxation testing protocols to characterize the leaflet tissue's mechanical properties. Finally, post-processing requires the use of data image correlation techniques and force and displacement readings to summarize the tissue's mechanical behaviors in response to external loading. In general, results from biaxial testing demonstrate that the leaflet tissues yield a nonlinear, anisotropic mechanical response. The presented biaxial testing procedure is advantageous to other methods since the method presented here allows for a more comprehensive characterization of the valve leaflet tissue under one unified testing scheme, as opposed to separate testing protocols on different tissue specimens. The proposed testing method has its limitations in that shear stress is potentially present in the tissue sample. However, any potential shear is presumed negligible.
Collapse
Affiliation(s)
- Colton Ross
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Devin Laurence
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma; Institute for Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma;
| |
Collapse
|
31
|
Comparative mechanical, morphological, and microstructural characterization of porcine mitral and tricuspid leaflets and chordae tendineae. Acta Biomater 2019; 85:241-252. [PMID: 30579963 DOI: 10.1016/j.actbio.2018.12.029] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 11/30/2018] [Accepted: 12/19/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND Healthy function of tricuspid valve (TV) structures is essential to avoid tricuspid regurgitation (TR) and may significantly improve disease prognosis. Mitral valve (MV) structures have been extensively studied, but little is known about the TV and right-sided heart diseases. Therefore, clinical decisions and finite element (FE) simulations often rely heavily on MV data for TV applications, despite fundamentally different mechanical and physiological environments. METHOD/RESULTS To bridge this gap, we performed a rigorous mechanical, morphological, and microstructural characterization of the MV and TV leaflets and chordae in a porcine model. Planar biaxial testing, uniaxial testing, second harmonic generation imaging and Verhoeff Van Gieson staining were performed. Morphological parameters, tissue moduli, extensibility, and anisotropy were quantified and compared. No major differences in leaflet mechanics or structure were found between TV and MV; chordal mechanics, morphology, and structure were found to compensate for anatomical and physiological loading differences between the valves. No differences in chordal mechanics were observed by insertion point within a leaflet; the septal tricuspid leaflet (STL) and posterior mitral leaflet (PML) did not have distinguishable strut chords, and the STL had the shortest chords. Within a valve, chords from septally-located leaflets were more extensible. MV chords were stiffer. CONCLUSIONS This study presents the first rigorous comparative mechanical and structural dataset of MV and TV structures. Valve type and anatomical location may be stronger predictors of chordal mechanics. Chords from septally-located leaflets differ from each other and from their intravalvular counterparts; they merit special consideration in surgical and computational applications. STATEMENT OF SIGNIFICANCE A better understanding of the tricuspid valve (TV) and its associated structures is important for making advancements towards the repair of tricuspid regurgitation. Mitral valve structures have been extensively studied, but little is known about the TV and right-sided heart diseases. Clinical decisions and computational simulations often rely heavily on MV data for TV applications, despite fundamentally different environments. We therefore performed a rigorous mechanical, morphological, and microstructural characterization of atrioventricular leaflets and chordae tendineae in a porcine model. Finding that valve type and anatomical location may be strong predictors of chordal mechanics, chords from septally-located leaflets differ from each other and from their intravalvular counterparts; they merit special consideration in surgical and computational applications.
Collapse
|
32
|
Rego BV, Khalighi AH, Drach A, Lai EK, Pouch AM, Gorman RC, Gorman JH, Sacks MS. A noninvasive method for the determination of in vivo mitral valve leaflet strains. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2018; 34:e3142. [PMID: 30133180 DOI: 10.1002/cnm.3142] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 06/21/2018] [Accepted: 08/07/2018] [Indexed: 06/08/2023]
Abstract
Assessment of mitral valve (MV) function is important in many diagnostic, prognostic, and surgical planning applications for treatment of MV disease. Yet, to date, there are no accepted noninvasive methods for determination of MV leaflet deformation, which is a critical metric of MV function. In this study, we present a novel, completely noninvasive computational method to estimate MV leaflet in-plane strains from clinical-quality real-time three-dimensional echocardiography (rt-3DE) images. The images were first segmented to produce meshed medial-surface leaflet geometries of the open and closed states. To establish material point correspondence between the two states, an image-based morphing pipeline was implemented within a finite element (FE) modeling framework in which MV closure was simulated by pressurizing the open-state geometry, and local corrective loads were applied to enforce the actual MV closed shape. This resulted in a complete map of local systolic leaflet membrane strains, obtained from the final FE mesh configuration. To validate the method, we utilized an extant in vitro database of fiducially labeled MVs, imaged in conditions mimicking both the healthy and diseased states. Our method estimated local anisotropic in vivo strains with less than 10% error and proved to be robust to changes in boundary conditions similar to those observed in ischemic MV disease. Next, we applied our methodology to ovine MVs imaged in vivo with rt-3DE and compared our results to previously published findings of in vivo MV strains in the same type of animal as measured using surgically sutured fiducial marker arrays. In regions encompassed by fiducial markers, we found no significant differences in circumferential(P = 0.240) or radial (P = 0.808) strain estimates between the marker-based measurements and our novel noninvasive method. This method can thus be used for model validation as well as for studies of MV disease and repair.
Collapse
Affiliation(s)
- Bruno V Rego
- Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas
| | - Amir H Khalighi
- Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas
| | - Andrew Drach
- Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas
| | - Eric K Lai
- Gorman Cardiovascular Research Group, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Alison M Pouch
- Gorman Cardiovascular Research Group, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Robert C Gorman
- Gorman Cardiovascular Research Group, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Joseph H Gorman
- Gorman Cardiovascular Research Group, Department of Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Michael S Sacks
- Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas
| |
Collapse
|
33
|
Laurence D, Ross C, Jett S, Johns C, Echols A, Baumwart R, Towner R, Liao J, Bajona P, Wu Y, Lee CH. An investigation of regional variations in the biaxial mechanical properties and stress relaxation behaviors of porcine atrioventricular heart valve leaflets. J Biomech 2018; 83:16-27. [PMID: 30497683 PMCID: PMC8008702 DOI: 10.1016/j.jbiomech.2018.11.015] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 10/17/2018] [Accepted: 11/08/2018] [Indexed: 10/27/2022]
Abstract
The facilitation of proper blood flow through the heart depends on proper function of heart valve components, and alterations to any component can lead to heart disease or failure. Comprehension of these valvular diseases is reliant on thorough characterization of healthy heart valve structures for use in computational models. Previously, computational models have treated these leaflet structures as a structurally and mechanically homogenous material, which may not be an accurate description of leaflet mechanical response. In this study, we aimed to characterize the mechanics of the heart valve leaflet as a structurally heterogenous material. Specifically, porcine mitral valve and tricuspid valve anterior leaflets were sectioned into six regions and biaxial mechanical tests with various loading ratios and stress-relaxation test were performed on each regional tissue sample. Three main findings from this study were summarized as follows: (i) the central regions of the leaflet had a more anisotropic nature than edge regions, (ii) the mitral valve anterior leaflet was more extensible in regions closer to the annulus, and (iii) there was variance in the stress-relaxation behavior among all six regions, with mitral valve leaflet tissue regions exhibiting a greater decay than the tricuspid valve regions. This study presents a novel investigation of the regional variations in the heart valve biomechanics that has not been comprehensively examined. Our results thus allow for a refinement of computational models for more accurately predicting diseased or surgically-intervened condition, where tissue heterogeneity plays an essential role in the heart valve function.
Collapse
Affiliation(s)
- Devin Laurence
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Colton Ross
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Samuel Jett
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Cortland Johns
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Allyson Echols
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Ryan Baumwart
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK 74078, USA
| | - Rheal Towner
- Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation, Oklahoma City, OK 73104, USA
| | - Jun Liao
- Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA
| | - Pietro Bajona
- Department of Cardiovascular and Thoracic Surgery, The University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Yi Wu
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology, The University of Oklahoma, Norman, OK 73019, USA.
| |
Collapse
|
34
|
A Thin Layer of Decellularized Porcine Myocardium for Cell Delivery. Sci Rep 2018; 8:16206. [PMID: 30385769 PMCID: PMC6212498 DOI: 10.1038/s41598-018-33946-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 10/08/2018] [Indexed: 01/11/2023] Open
Abstract
Decellularized porcine myocardium has shown many benefits as a cell delivery scaffold for cardiac therapy. However, using full thickness decellularized myocardium as cardiac patch may lead to poor viability and inhomogeneous distribution of delivered cells, due to perfusion limitations. In this study, we explored the feasibility of decellularized porcine myocardial slice (dPMS) to construct a vascularized cardiac patch for cell delivery. Decellularized porcine myocardium was sliced into thin layers (thickness~300 µm). Adipose-derived Stem cells (ASCs) obtained from rat and pig were seeded on dPMS. The viability, infiltration, and differentiation of seeded ASCs were examined. The mechanical properties of dPMSs of various thickness and native myocardium were tested. We noticed dPMS supported attachment and growth of rat and pig ASCs. Both rat and pig ASCs showed high viability, similar patterns of proliferation and infiltration within dPMS. Rat ASCs showed expression of early-endothelial markers followed by mature-endothelial marker without any additional inducers on dPMS. Using rat myocardial infarction model, we delivered ASCs using dPMS patched to the infarcted myocardium. After 1 week, a higher number of transplanted cells were present in the infarcted area when cells were delivered using dPMS versus direct injection. Compared with MI group, increased vascular formation was also observed.
Collapse
|
35
|
Ahmad F, Prabhu RJ, Liao J, Soe S, Jones MD, Miller J, Berthelson P, Enge D, Copeland KM, Shaabeth S, Johnston R, Maconochie I, Theobald PS. Biomechanical properties and microstructure of neonatal porcine ventricles. J Mech Behav Biomed Mater 2018; 88:18-28. [PMID: 30118921 DOI: 10.1016/j.jmbbm.2018.07.038] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 06/26/2018] [Accepted: 07/27/2018] [Indexed: 12/29/2022]
Abstract
Neonatal heart disorders represent a major clinical challenge, with congenital heart disease alone affecting 36,000 new-borns annually within the European Union. Surgical intervention to restore normal function includes the implantation of synthetic and biological materials; however, a lack of experimental data describing the mechanical behaviour of neonatal cardiac tissue is likely to contribute to the relatively poor short- and long-term outcome of these implants. This study focused on characterising the mechanical behaviour of neonatal cardiac tissue using a porcine model, to enhance the understanding of how this differs to the equivalent mature tissue. The biomechanical properties of neonatal porcine cardiac tissue were characterised by uniaxial tensile, biaxial tensile, and simple shear loading modes, using samples collected from the anterior and posterior walls of the right and left ventricles. Histological images were prepared using Masson's trichrome staining, to enable assessment of the microstructure and correlation with tissue behaviour. The mechanical tests demonstrated that the neonatal cardiac tissue is non-linear, anisotropic, viscoelastic and heterogeneous. Our data provide a baseline describing the biomechanical behaviour of immature porcine cardiac tissue. Comparison with published data also indicated that the neonatal porcine cardiac tissue exhibits one-half the stiffness of mature porcine tissue in uniaxial extension testing, one-third in biaxial extension testing, and one-fourth stiffness in simple shear testing; hence, it provides an indication as to the relative change in characteristics associated with tissue maturation. These data may prove valuable to researchers investigating neonatal cardiac mechanics.
Collapse
Affiliation(s)
| | - Ra J Prabhu
- Centre for Advanced Vehicular Systems and Department of Biological Engineering, Mississippi State University, USA
| | - Jun Liao
- Centre for Advanced Vehicular Systems and Department of Biological Engineering, Mississippi State University, USA; Department of Bioengineering, The University of Texas at Arlington, USA.
| | - Shwe Soe
- School of Engineering, Cardiff University, UK
| | | | - Jonathan Miller
- Centre for Advanced Vehicular Systems and Department of Biological Engineering, Mississippi State University, USA
| | - Parker Berthelson
- Centre for Advanced Vehicular Systems and Department of Biological Engineering, Mississippi State University, USA
| | | | | | | | | | | | | |
Collapse
|
36
|
Jett S, Laurence D, Kunkel R, Babu AR, Kramer K, Baumwart R, Towner R, Wu Y, Lee CH. An investigation of the anisotropic mechanical properties and anatomical structure of porcine atrioventricular heart valves. J Mech Behav Biomed Mater 2018; 87:155-171. [PMID: 30071486 PMCID: PMC8008704 DOI: 10.1016/j.jmbbm.2018.07.024] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Revised: 05/05/2018] [Accepted: 07/15/2018] [Indexed: 11/18/2022]
Abstract
Valvular heart diseases are complex disorders, varying in pathophysiological mechanism and affected valve components. Understanding the effects of these diseases on valve functionality requires a thorough characterization of the mechanics and structure of the healthy heart valves. In this study, we performed biaxial mechanical experiments with extensive testing protocols to examine the mechanical behaviors of the mitral valve and tricuspid valve leaflets. We also investigated the effect of loading rate, testing temperatures, species (porcine versus ovine hearts), and age (juvenile vs adult ovine hearts) on the mechanical responses of the leaflet tissues. In addition, we evaluated the structure of chordae tendineae within each valve and performed histological analysis on each atrioventricular leaflet. We found all tissues displayed a characteristic nonlinear anisotropic mechanical response, with radial stretches on average 30.7% higher than circumferential stretches under equibiaxial physiological loading. Tissue mechanical responses showed consistent mechanical stiffening in response to increased loading rate and minor temperature dependence in all five atrioventricular heart valve leaflets. Moreover, our anatomical study revealed similar chordae quantities in the porcine mitral (30.5 ± 1.43 chords) and tricuspid valves (35.3 ± 2.45 chords) but significantly more chordae in the porcine than the ovine valves (p < 0.010). Our histological analyses quantified the relative thicknesses of the four distinct morphological layers in each leaflet. This study provides a comprehensive database of the mechanics and structure of the atrioventricular valves, which will be beneficial to development of subject-specific atrioventricular valve constitutive models and toward multi-scale biomechanical investigations of heart valve function to improve valvular disease treatments.
Collapse
Affiliation(s)
- Samuel Jett
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Devin Laurence
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Robert Kunkel
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Anju R Babu
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Katherine Kramer
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Ryan Baumwart
- Center for Veterinary Health Sciences, Oklahoma State University, 208 S. McFarland Street, Stillwater, OK 74078, USA
| | - Rheal Towner
- Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation 825 N.E. 13th Street, Oklahoma City, OK 73104, USA
| | - Yi Wu
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA
| | - Chung-Hao Lee
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219 C, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma, Norman, OK 73019, USA.
| |
Collapse
|
37
|
Potter S, Graves J, Drach B, Leahy T, Hammel C, Feng Y, Baker A, Sacks MS. A Novel Small-Specimen Planar Biaxial Testing System With Full In-Plane Deformation Control. J Biomech Eng 2018; 140:2666965. [PMID: 29247251 PMCID: PMC5816250 DOI: 10.1115/1.4038779] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 12/11/2017] [Indexed: 01/12/2023]
Abstract
Simulations of soft tissues require accurate and robust constitutive models, whose form is derived from carefully designed experimental studies. For such investigations of membranes or thin specimens, planar biaxial systems have been used extensively. Yet, all such systems remain limited in their ability to: (1) fully prescribe in-plane deformation gradient tensor F2D, (2) ensure homogeneity of the applied deformation, and (3) be able to accommodate sufficiently small specimens to ensure a reasonable degree of material homogeneity. To address these issues, we have developed a novel planar biaxial testing device that overcomes these difficulties and is capable of full control of the in-plane deformation gradient tensor F2D and of testing specimens as small as ∼4 mm × ∼4 mm. Individual actuation of the specimen attachment points, combined with a robust real-time feedback control, enabled the device to enforce any arbitrary F2D with a high degree of accuracy and homogeneity. Results from extensive device validation trials and example tissues illustrated the ability of the device to perform as designed and gather data needed for developing and validating constitutive models. Examples included the murine aortic tissues, allowing for investigators to take advantage of the genetic manipulation of murine disease models. These capabilities highlight the potential of the device to serve as a platform for informing and verifying the results of inverse models and for conducting robust, controlled investigation into the biomechanics of very local behaviors of soft tissues and membrane biomaterials.
Collapse
Affiliation(s)
- Samuel Potter
- Department of Mechanical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 240 East 24th Street, Austin, TX 78712
| | - Jordan Graves
- Department of Biomedical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, , Austin, TX 78712
| | - Borys Drach
- Department of Mechanical and Aerospace Engineering, New Mexico State University, Las Cruces, NM 88003
| | - Thomas Leahy
- Department of Biomedical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, , Austin, TX 78712
| | - Chris Hammel
- Department of Mechanical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, , Austin, TX 78712
| | - Yuan Feng
- Center for Molecular Imaging and Nuclear Medicine, School of Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China
| | - Aaron Baker
- Department of Biomedical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, The University of Texas at Austin, , Austin, TX 78712
| | - Michael S Sacks
- Department of Biomedical Engineering, Willerson Center for Cardiovascular Modeling and Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, , Austin, TX 78712
| |
Collapse
|
38
|
Pant AD, Thomas VS, Black AL, Verba T, Lesicko JG, Amini R. Pressure-induced microstructural changes in porcine tricuspid valve leaflets. Acta Biomater 2018; 67:248-258. [PMID: 29199067 DOI: 10.1016/j.actbio.2017.11.040] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 10/24/2017] [Accepted: 11/13/2017] [Indexed: 12/20/2022]
Abstract
Quantifying mechanically-induced changes in the tricuspid valve extracellular matrix (ECM) structural components, e.g. collagen fiber spread and distribution, is important as it determines the overall macro-scale tissue responses and subsequently its function/malfunction in physiological/pathophysiological states. For example, functional tricuspid regurgitation, a common tricuspid valve disorder, could be caused by elevated right ventricular pressure due to pulmonary hypertension. In such patients, the geometry and the normal function of valve leaflets alter due to chronic pressure overload, which could cause remodeling responses in the ECM and change its structural components. To understand such a relation, we developed an experimental setup and measured alteration of leaflet microstructure in response to pressure increase in porcine tricuspid valves using the small angle light scattering technique. The anisotropy index, a measure of the fiber spread and distribution, was obtained and averaged for each region of the anterior, posterior, and septal leaflet using four averaging methods. The average anisotropy indices (mean ± standard error) in the belly region of the anterior, posterior, and septal leaflets of non-pressurized valves were found to be 12 ± 2%, 21 ± 3% and 12 ± 1%, respectively. For the pressurized valve, the average values of the anisotropy index in the belly region of the anterior, posterior, and septal leaflets were 56 ± 5%, 39 ± 7% and 32 ± 5%, respectively. Overall, the average anisotropy index was found to be higher for all leaflets in the pressurized valves as compared to the non-pressurized valves, indicating that the ECM fibers became more aligned in response to an increased ventricular pressure. STATEMENT OF SIGNIFICANCE Mechanics plays a critical role in development, regeneration, and remodeling of tissues. In the current study, we have conducted experiments to examine how increasing the ventricular pressure leads to realignment of protein fibers comprising the extracellular matrix (ECM) of the tricuspid valve leaflets. Like many other tissues, in cardiac valves, cell-matrix interactions and gene expressions are heavily influenced by changes in the mechanical microenvironment at the ECM/cellular level. We believe that our study will help us better understand how abnormal increases in the right ventricular pressure (due to pulmonary hypertension) could change the structural architecture of tricuspid valve leaflets and subsequently the mechanical microenvironment at the ECM/cellular level.
Collapse
Affiliation(s)
- Anup D Pant
- Department of Biomedical Engineering, The University of Akron, Akron, OH, United States.
| | - Vineet S Thomas
- Department of Biomedical Engineering, The University of Akron, Akron, OH, United States.
| | - Anthony L Black
- Department of Biomedical Engineering, The University of Akron, Akron, OH, United States.
| | - Taylor Verba
- Department of Biomedical Engineering, The University of Akron, Akron, OH, United States.
| | | | - Rouzbeh Amini
- Department of Biomedical Engineering, The University of Akron, Akron, OH, United States.
| |
Collapse
|
39
|
Ayoub S, Lee CH, Driesbaugh KH, Anselmo W, Hughes CT, Ferrari G, Gorman RC, Gorman JH, Sacks MS. Regulation of valve interstitial cell homeostasis by mechanical deformation: implications for heart valve disease and surgical repair. J R Soc Interface 2017; 14:20170580. [PMID: 29046338 PMCID: PMC5665836 DOI: 10.1098/rsif.2017.0580] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2017] [Accepted: 09/21/2017] [Indexed: 11/12/2022] Open
Abstract
Mechanical stress is one of the major aetiological factors underlying soft-tissue remodelling, especially for the mitral valve (MV). It has been hypothesized that altered MV tissue stress states lead to deviations from cellular homeostasis, resulting in subsequent cellular activation and extracellular matrix (ECM) remodelling. However, a quantitative link between alterations in the organ-level in vivo state and in vitro-based mechanobiology studies has yet to be made. We thus developed an integrated experimental-computational approach to elucidate MV tissue and interstitial cell responses to varying tissue strain levels. Comprehensive results at different length scales revealed that normal responses are observed only within a defined range of tissue deformations, whereas deformations outside of this range lead to hypo- and hyper-synthetic responses, evidenced by changes in α-smooth muscle actin, type I collagen, and other ECM and cell adhesion molecule regulation. We identified MV interstitial cell deformation as a key player in leaflet tissue homeostatic regulation and, as such, used it as the metric that makes the critical link between in vitro responses to simulated equivalent in vivo behaviour. Results indicated that cell responses have a delimited range of in vivo deformations that maintain a homeostatic response, suggesting that deviations from this range may lead to deleterious tissue remodelling and failure.
Collapse
Affiliation(s)
- Salma Ayoub
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences (ICES), Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| | - Chung-Hao Lee
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
| | - Kathryn H Driesbaugh
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Wanda Anselmo
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Connor T Hughes
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences (ICES), Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| | - Giovanni Ferrari
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Robert C Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Joseph H Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Michael S Sacks
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences (ICES), Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| |
Collapse
|
40
|
Baxter J, Buchan KG, Espino DM. Viscoelastic properties of mitral valve leaflets: An analysis of regional variation and frequency-dependency. Proc Inst Mech Eng H 2017; 231:938-944. [PMID: 28707559 DOI: 10.1177/0954411917719741] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The aim of this study was to determine the regional variation in viscoelastic properties of mitral valve leaflets over a range of physiological and patho-physiological frequencies. This included comparisons to be made between anterior and posterior leaflets, anterior leaflet clear and rough zones, and radial and circumferential leaflet orientation. Dynamic mechanical analysis was used to determine frequency-dependent viscoelastic properties. The valve leaflets were dissected from eight porcine hearts. The leaflets were loaded under a sinusoidal tensile displacement, with a mean dynamic peak to trough strain of 11%, applied to all leaflet samples at nine different frequencies, ranging from 0.5 to 10 Hz. The anterior leaflet has higher storage and loss stiffness than the posterior leaflet. The storage stiffness of circumferential tissue is greater than that of radially oriented valve tissue (2.0 ± 1.6 N/mm cf. 1.7 ± 0.9 N/mm; p < 0.05); however, the loss stiffness is greater for radial tissue (0.15 ± 0.07 cf. 0.14 ± 0.09 N/mm; p < 0.05). Likewise, the storage stiffness of the anterior leaflet clear zone is greater than that of the rough zone (2.4 ± 1.6 cf. 2.1 ± 1.2; p < 0.05), but the loss stiffness is greater for the rough zone (0.17 ± 0.09 N/mm cf. 0.14 ± 0.08 N/mm; p < 0.05). In conclusion, the viscoelastic properties of porcine mitral valve leaflets have regional variations, with dynamic stiffness being dependent on circumferential or radial orientation and on location at a clear or rough zones.
Collapse
Affiliation(s)
- Jonathan Baxter
- 1 Department of Mechanical Engineering, University of Birmingham, Birmingham, UK
| | - Keith G Buchan
- 2 Cardiothoracic Surgery, Aberdeen Royal Infirmary, Aberdeen, UK
| | - Daniel M Espino
- 1 Department of Mechanical Engineering, University of Birmingham, Birmingham, UK
| |
Collapse
|
41
|
Quantification and comparison of the mechanical properties of four human cardiac valves. Acta Biomater 2017; 54:345-355. [PMID: 28336153 DOI: 10.1016/j.actbio.2017.03.026] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 02/21/2017] [Accepted: 03/16/2017] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. METHODS A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. RESULTS The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). CONCLUSIONS Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. STATEMENT OF SIGNIFICANCE Most research on heart valve mechanics have been conducted mainly on mitral and aortic valves or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same relatively healthy elderly patient population. In this study, the mechanical and microstructural properties of 114 leaflets of aortic, mitral, pulmonary and tricuspid valves from 12 human cadaver hearts were mechanically tested, analyzed and compared. Our results not only provided a baseline quantification of the mechanical properties of aged human valves, but a age range between patients (51-87years) also offers a better understanding of the age-dependent differences among the four valves. It is hoped that the obtained experimental data and associated constitutive parameters can facilitate studies of valve diseases, treatments and the development of interventional devices.
Collapse
|
42
|
Lee CH, Zhang W, Feaver K, Gorman RC, Gorman JH, Sacks MS. On the in vivo function of the mitral heart valve leaflet: insights into tissue-interstitial cell biomechanical coupling. Biomech Model Mechanobiol 2017; 16:1613-1632. [PMID: 28429161 DOI: 10.1007/s10237-017-0908-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Accepted: 04/07/2017] [Indexed: 10/19/2022]
Abstract
There continues to be a critical need for developing data-informed computational modeling techniques that enable systematic evaluations of mitral valve (MV) function. This is important for a better understanding of MV organ-level biomechanical performance, in vivo functional tissue stresses, and the biosynthetic responses of MV interstitial cells (MVICs) in the normal, pathophysiological, and surgically repaired states. In the present study, we utilized extant ovine MV population-averaged 3D fiducial marker data to quantify the MV anterior leaflet (MVAL) deformations in various kinematic states. This approach allowed us to make the critical connection between the in vivo functional and the in vitro experimental configurations. Moreover, we incorporated the in vivo MVAL deformations and pre-strains into an enhanced inverse finite element modeling framework (Path 1) to estimate the resulting in vivo tissue prestresses [Formula: see text] and the in vivo peak functional tissue stresses [Formula: see text]. These in vivo stress estimates were then cross-verified with the results obtained from an alternative forward modeling method (Path 2), by taking account of the changes in the in vitro and in vivo reference configurations. Moreover, by integrating the tissue-level kinematic results into a downscale MVIC microenvironment FE model, we were able to estimate, for the first time, the in vivo layer-specific MVIC deformations and deformation rates of the normal and surgically repaired MVALs. From these simulations, we determined that the placement of annuloplasty ring greatly reduces the peak MVIC deformation levels in a layer-specific manner. This suggests that the associated reductions in MVIC deformation may down-regulate MV extracellular matrix maintenance, ultimately leading to reduction in tissue mechanical integrity. These simulations provide valuable insight into MV cellular mechanobiology in response to organ- and tissue-level alternations induced by MV disease or surgical repair. They will also assist in the future development of computer simulation tools for guiding MV surgery procedure with enhanced durability and improved long-term surgical outcomes.
Collapse
Affiliation(s)
- Chung-Hao Lee
- School of Aerospace and Mechanical Engineering, The University of Oklahoma, 865 Asp Ave., Felgar Hall, Rm. 219C, Norman, OK, 73019, USA.,Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, POB 5.236, 1 University Station, C0200, Austin, TX, 78712, USA
| | - Will Zhang
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, POB 5.236, 1 University Station, C0200, Austin, TX, 78712, USA
| | - Kristen Feaver
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, POB 5.236, 1 University Station, C0200, Austin, TX, 78712, USA
| | - Robert C Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, 3400 Civic Center Blvd, Philadelphia, PA, 19104, USA
| | - Joseph H Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, 3400 Civic Center Blvd, Philadelphia, PA, 19104, USA
| | - Michael S Sacks
- Department of Biomedical Engineering, Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th St, POB 5.236, 1 University Station, C0200, Austin, TX, 78712, USA. .,W. A. Moncrief, Jr. Simulation-Based Engineering Science Chair I, Department of Biomedical Engineering, Institute for Computational Engineering and Sciences, The University of Texas at Austin, 201 East 24th Street, ACES 5.438, 1 University Station, C0200, Austin, TX, 78712-0027, USA.
| |
Collapse
|
43
|
Menciotti G, Borgarelli M, Aherne M, Wesselowski S, Häggström J, Ljungvall I, Lahmers S, Abbott J. Mitral valve morphology assessed by three-dimensional transthoracic echocardiography in healthy dogs and dogs with myxomatous mitral valve disease. J Vet Cardiol 2017; 19:113-123. [DOI: 10.1016/j.jvc.2017.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 12/12/2016] [Accepted: 01/02/2017] [Indexed: 01/15/2023]
|
44
|
Tam H, Zhang W, Infante D, Parchment N, Sacks M, Vyavahare N. Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties. J Cardiovasc Transl Res 2017; 10:194-205. [PMID: 28213846 DOI: 10.1007/s12265-017-9733-5] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Accepted: 01/26/2017] [Indexed: 10/20/2022]
Abstract
Bioprosthetic heart valves (BHVs), derived from glutaraldehyde crosslinked (GLUT) porcine aortic valve leaflets or bovine pericardium (BP), are used to replace defective heart valves. However, valve failure can occur within 12-15 years due to calcification and/or progressive structural degeneration. We present a novel fabrication method that utilizes carbodiimide, neomycin trisulfate, and pentagalloyl glucose crosslinking chemistry (TRI) to better stabilize the extracellular matrix of BP. We demonstrate that TRI-treated BP is more compliant than GLUT-treated BP. GLUT-treated BP exhibited permanent geometric deformation and complete alteration of apparent mechanical properties when subjected to induced static strain. TRI BP, on the other hand, did not exhibit such permanent geometric deformations or significant alterations of apparent mechanical properties. TRI BP also exhibited better resistance to enzymatic degradation in vitro and calcification in vivo when implanted subcutaneously in juvenile rats for up to 30 days.
Collapse
Affiliation(s)
- H Tam
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - W Zhang
- Department of Biomedical Engineering, University of Texas, Austin, TX, USA
| | - D Infante
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - N Parchment
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA
| | - M Sacks
- Department of Biomedical Engineering, University of Texas, Austin, TX, USA
| | - N Vyavahare
- Department of Bioengineering, Clemson University, Clemson, SC, 29634, USA.
| |
Collapse
|
45
|
Mattson JM, Turcotte R, Zhang Y. Glycosaminoglycans contribute to extracellular matrix fiber recruitment and arterial wall mechanics. Biomech Model Mechanobiol 2017; 16:213-225. [PMID: 27491312 PMCID: PMC5288264 DOI: 10.1007/s10237-016-0811-4] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Accepted: 07/26/2016] [Indexed: 01/15/2023]
Abstract
Elastic and collagen fibers are well known to be the major load-bearing extracellular matrix (ECM) components of the arterial wall. Studies of the structural components and mechanics of arterial ECM generally focus on elastin and collagen fibers, and glycosaminoglycans (GAGs) are often neglected. Although GAGs represent only a small component of the vessel wall ECM, they are considerably important because of their diverse functionality and their role in pathological processes. The goal of this study was to study the mechanical and structural contributions of GAGs to the arterial wall. Biaxial tensile testing was paired with multiphoton microscopic imaging of elastic and collagen fibers in order to establish the structure-function relationships of porcine thoracic aorta before and after enzymatic GAG removal. Removal of GAGs results in an earlier transition point of the nonlinear stress-strain curves [Formula: see text]. However, stiffness was not significantly different after GAG removal treatment, indicating earlier but not absolute stiffening. Multiphoton microscopy showed that when GAGs are removed, the adventitial collagen fibers are straighter, and both elastin and collagen fibers are recruited at lower levels of strain, in agreement with the mechanical change. The amount of stress relaxation also decreased in GAG-depleted arteries [Formula: see text]. These findings suggest that the interaction between GAGs and other ECM constituents plays an important role in the mechanics of the arterial wall, and GAGs should be considered in addition to elastic and collagen fibers when studying arterial function.
Collapse
Affiliation(s)
- Jeffrey M Mattson
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | - Raphaël Turcotte
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
- Advanced Microscopy Program, Center for Systems Biology, Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Yanhang Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
46
|
Sirry MS, Butler JR, Patnaik SS, Brazile B, Bertucci R, Claude A, McLaughlin R, Davies NH, Liao J, Franz T. Characterisation of the mechanical properties of infarcted myocardium in the rat under biaxial tension and uniaxial compression. J Mech Behav Biomed Mater 2016; 63:252-264. [DOI: 10.1016/j.jmbbm.2016.06.029] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 06/20/2016] [Accepted: 06/29/2016] [Indexed: 11/26/2022]
|
47
|
Liberski A, Ayad N, Wojciechowska D, Zielińska D, Struszczyk MH, Latif N, Yacoub M. Knitting for heart valve tissue engineering. Glob Cardiol Sci Pract 2016; 2016:e201631. [PMID: 29043276 PMCID: PMC5642840 DOI: 10.21542/gcsp.2016.31] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Knitting is a versatile technology which offers a large portfolio of products and solutions of interest in heart valve (HV) tissue engineering (TE). One of the main advantages of knitting is its ability to construct complex shapes and structures by precisely assembling the yarns in the desired position. With this in mind, knitting could be employed to construct a HV scaffold that closely resembles the authentic valve. This has the potential to reproduce the anisotropic structure that is characteristic of the heart valve with the yarns, in particular the 3-layered architecture of the leaflets. These yarns can provide oriented growth of cells lengthwise and consequently enable the deposition of extracellular matrix (ECM) proteins in an oriented manner. This technique, therefore, has a potential to provide a functional knitted scaffold, but to achieve that textile engineers need to gain a basic understanding of structural and mechanical aspects of the heart valve and in addition, tissue engineers must acquire the knowledge of tools and capacities that are essential in knitting technology. The aim of this review is to provide a platform to consolidate these two fields as well as to enable an efficient communication and cooperation among these two research areas.
Collapse
Affiliation(s)
- Albert Liberski
- Sidra Medical and Research Center, P.O. Box 26999, Doha, Qatar
| | - Nadia Ayad
- Mechanical Engineering and Material Science Department, Military Institute of Engineering (IME), Rio de Janeiro, RJ, Brazil
| | - Dorota Wojciechowska
- Lodz University of Technology, Faculty of Material Technologies and Textile Design, Department of Material and Commodity Sciences and Textile Metrology, ul. Zeromskiego 116, 90-924, Lodz, Poland
| | - Dorota Zielińska
- Institute of Security Technologies "Moratex" 3 M, Skłodowskiej-Curie Street 90-505 Lodz, Poland
| | - Marcin H Struszczyk
- Institute of Security Technologies "Moratex" 3 M, Skłodowskiej-Curie Street 90-505 Lodz, Poland
| | - Najma Latif
- Imperial College of Science and Technology, London, UK
| | - Magdi Yacoub
- Sidra Medical and Research Center, P.O. Box 26999, Doha, Qatar
| |
Collapse
|
48
|
Ayoub S, Ferrari G, Gorman RC, Gorman JH, Schoen FJ, Sacks MS. Heart Valve Biomechanics and Underlying Mechanobiology. Compr Physiol 2016; 6:1743-1780. [PMID: 27783858 PMCID: PMC5537387 DOI: 10.1002/cphy.c150048] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Heart valves control unidirectional blood flow within the heart during the cardiac cycle. They have a remarkable ability to withstand the demanding mechanical environment of the heart, achieving lifetime durability by processes involving the ongoing remodeling of the extracellular matrix. The focus of this review is on heart valve functional physiology, with insights into the link between disease-induced alterations in valve geometry, tissue stress, and the subsequent cell mechanobiological responses and tissue remodeling. We begin with an overview of the fundamentals of heart valve physiology and the characteristics and functions of valve interstitial cells (VICs). We then provide an overview of current experimental and computational approaches that connect VIC mechanobiological response to organ- and tissue-level deformations and improve our understanding of the underlying functional physiology of heart valves. We conclude with a summary of future trends and offer an outlook for the future of heart valve mechanobiology, specifically, multiscale modeling approaches, and the potential directions and possible challenges of research development. © 2016 American Physiological Society. Compr Physiol 6:1743-1780, 2016.
Collapse
Affiliation(s)
- Salma Ayoub
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, USA
| | - Giovanni Ferrari
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, USA
| | - Robert C. Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, USA
| | - Joseph H. Gorman
- Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, USA
| | - Frederick J. Schoen
- Department of Pathology, Brigham and Women’s Hospital, Boston, Massachusetts, USA
| | - Michael S. Sacks
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, Austin, USA
| |
Collapse
|
49
|
Amini Khoiy K, Amini R. On the Biaxial Mechanical Response of Porcine Tricuspid Valve Leaflets. J Biomech Eng 2016; 138:2545527. [DOI: 10.1115/1.4034426] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Indexed: 12/16/2022]
Abstract
Located on the right side of the heart, the tricuspid valve (TV) prevents blood backflow from the right ventricle to the right atrium. Similar to other cardiac valves, quantification of TV biaxial mechanical properties is essential in developing accurate computational models. In the current study, for the first time, the biaxial stress–strain behavior of porcine TV was measured ex vivo under different loading protocols using biaxial tensile testing equipment. The results showed a highly nonlinear response including a compliant region followed by a rapid transition to a stiff region for all of the TV leaflets both in the circumferential and in the radial directions. Based on the data analysis, all three leaflets were found to be anisotropic, and they were stiffer in the circumferential direction in comparison to the radial direction. It was also concluded that the posterior leaflet was the most anisotropic leaflet.
Collapse
Affiliation(s)
- Keyvan Amini Khoiy
- Department of Biomedical Engineering, The University of Akron, Olson Research Center, Room 322/3, 260 South Forge Street, Akron, OH 44325 e-mail:
| | - Rouzbeh Amini
- Mem. ASME Department of Biomedical Engineering, The University of Akron, Olson Research Center, Room 301F, 260 South Forge Street, Akron, OH 44325 e-mail:
| |
Collapse
|
50
|
Soares JS, Feaver KR, Zhang W, Kamensky D, Aggarwal A, Sacks MS. Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance. Cardiovasc Eng Technol 2016; 7:309-351. [PMID: 27507280 DOI: 10.1007/s13239-016-0276-8] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 07/13/2016] [Indexed: 12/11/2022]
Abstract
The use of replacement heart valves continues to grow due to the increased prevalence of valvular heart disease resulting from an ageing population. Since bioprosthetic heart valves (BHVs) continue to be the preferred replacement valve, there continues to be a strong need to develop better and more reliable BHVs through and improved the general understanding of BHV failure mechanisms. The major technological hurdle for the lifespan of the BHV implant continues to be the durability of the constituent leaflet biomaterials, which if improved can lead to substantial clinical impact. In order to develop improved solutions for BHV biomaterials, it is critical to have a better understanding of the inherent biomechanical behaviors of the leaflet biomaterials, including chemical treatment technologies, the impact of repetitive mechanical loading, and the inherent failure modes. This review seeks to provide a comprehensive overview of these issues, with a focus on developing insight on the mechanisms of BHV function and failure. Additionally, this review provides a detailed summary of the computational biomechanical simulations that have been used to inform and develop a higher level of understanding of BHV tissues and their failure modes. Collectively, this information should serve as a tool not only to infer reliable and dependable prosthesis function, but also to instigate and facilitate the design of future bioprosthetic valves and clinically impact cardiology.
Collapse
Affiliation(s)
- Joao S Soares
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA
| | - Kristen R Feaver
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA
| | - Will Zhang
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA
| | - David Kamensky
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA
| | - Ankush Aggarwal
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA
- College of Engineering, Swansea University, Bay Campus, Fabian Way, Swansea, SA1 8EN, UK
| | - Michael S Sacks
- Center for Cardiovascular Simulation, Institute for Computational Engineering and Sciences, Department of Biomedical Engineering, The University of Texas at Austin, 201 East 24th Street, Stop C0200, Austin, TX, 78712-1129, USA.
| |
Collapse
|