1
|
Gholami M, Souraki BA, Shomali A, Pendashteh A. Saline wastewater treatment by bioelectrochemical process (BEC) based on Al-electrocoagulation and halophilic bacteria: optimization using ANN with new approach. ENVIRONMENTAL TECHNOLOGY 2024; 45:4419-4439. [PMID: 37640518 DOI: 10.1080/09593330.2023.2253365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 08/17/2023] [Indexed: 08/31/2023]
Abstract
ABSTRACTIn the present study, a bioelectrochemical reactor (BEC) was utilized to treat two types of real saline produced water (PW). BEC was designed based on the combination of electrocoagulation (EC) process with halophilic microorganisms, and it was assessed in terms of biodegradation of hydrocarbons. The effects of various operating parameters including the current density, electrical contact time (On/Off), hydraulic retention time (HRT), and total dissolved solids (TDS) at different levels on the chemical oxygen demand (COD) removal efficiency, settleability, and performance of isolated halophilic microorganisms were examined. Additionally, a novel neural network (ANN) approach modelling using adaptive factors was used to predict and optimize the effects and interactions between operating parameters during BEC process by predicting complicated mechanisms and variations associated with microorganisms. In addition, a new algorithm was developed for the sensitivity analysis to achieve the optimum operating conditions and obtain maximum efficiency in COD removal, sludge volume index (SVI), mixed liquor suspended solids (MLSS), and specific electrical energy consumption (SEEC), simultaneously. BEC was found to be significantly more effective at removing most hydrocarbons, particularly pristine and phytane. In addition, the results showed a significant improvement in settling ability of the biological flocs with average SVI of 91.5 mL/g and a size of 178.25 μm using BEC. Based on estimated operating costs and energy consumption, BEC was more cost-effective and efficient than other bioelectrochemical systems.
Collapse
Affiliation(s)
- Moeen Gholami
- Department of Chemical Engineering, Faculty of Engineering, University of Guilan, Rasht, Iran
- Department of Civil and Natural Resources Engineering, University of Canterbury, Christchurch, New Zealand
| | - Behrooz Abbasi Souraki
- Department of Chemical Engineering, Faculty of Engineering, University of Guilan, Rasht, Iran
| | - Abbas Shomali
- Department of Chemical Engineering, Faculty of Engineering, University of Guilan, Rasht, Iran
| | - Alireza Pendashteh
- Department of Chemical Engineering, Faculty of Engineering, University of Guilan, Rasht, Iran
- Department of Water Engineering and Environment, The Caspian Sea Basin Research Center, University of Guilan, Rasht, Iran
| |
Collapse
|
2
|
Kumar P, Nawaz T, Singh SP. Optimization of electrocoagulation process parameters for the treatment of oil industry drill site wastewater. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:47101-47115. [PMID: 38987516 DOI: 10.1007/s11356-024-34189-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Accepted: 06/26/2024] [Indexed: 07/12/2024]
Abstract
The effluent from the oil drilling site is a complex mixture of hazardous chemicals that causes environmental impacts on its disposal. The treatment of oil drill-site wastewater has not been explored much, and understanding its characteristics and optimizing the treatment process are required. In the present study, we have optimized the electrocoagulation process with aluminum electrodes for drill-site wastewater treatment. A multi-level factorial center composite design using response surface methodology is applied to optimize the effect of current density (CD), pH, and inter-electrode distance (IED) on chemical oxygen demand (COD) removal. The increasing current density shows a significant increase in COD removal, and a similar trend was observed with a decreased pH. It was found that with current density and inter-electrode distance, the maximum COD removal achieved was 70% at the CD of 19.04 mA cm-2 and IED 2.6 cm. By varying pH and current density, the COD removal reached up to 90% at pH 6 and CD 19.04 mA cm-2. The study shows that the current density is the dominant factor for the process's energy consumption and operating cost, followed by pH. This study's findings could be effectively used to develop large-scale treatment processes through electrocoagulation.
Collapse
Affiliation(s)
- Pramod Kumar
- Environmental Science and Engineering Department (ESED), Indian Institute of Technology Bombay, Mumbai, 400076, India
| | - Tabish Nawaz
- Environmental Science and Engineering Department (ESED), Indian Institute of Technology Bombay, Mumbai, 400076, India
| | - Swatantra P Singh
- Environmental Science and Engineering Department (ESED), Indian Institute of Technology Bombay, Mumbai, 400076, India.
- Centre for Research in Nanotechnology & Science (CRNTS), Indian Institute of Technology Bombay, Mumbai, 400076, India.
- Interdisciplinary Program in Climate Studies, Indian Institute of Technology Bombay, Mumbai, 400076, India.
- Centre of Excellence On Membrane Technologies for Desalination, Brine Management, and Water Recycling (DeSaltM), Indian Institute of Technology Bombay, Mumbai, 400076, India.
| |
Collapse
|
3
|
Singh K, Prasad B, Kumar A, Kumari M, Dubey D, Sillanpää M, Prasad KS. Hyphenated Fenton-column packed nMnO-modified wood biochar for tannery effluent treatment: Adsorption mechanism and reusability study. ENVIRONMENTAL RESEARCH 2024; 252:118786. [PMID: 38537743 DOI: 10.1016/j.envres.2024.118786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 03/20/2024] [Accepted: 03/23/2024] [Indexed: 04/02/2024]
Abstract
Industrial wastewater contains a wide range of pollutants that, if released directly into natural ecosystems, have the potential to pose serious risks to the environment.This study aims to investigate sustainable and efficient approaches for treating tannery wastewater, employing a combination of hyphenated Fenton oxidation and adsorption processes. Rigorous analyses were conducted on wastewater samples, evaluating parameters like COD, sulphide, NH3-N, PO43-, NO3-, and Cr(VI). The performance of this adsorbent material was gauged through column adsorption experiments. A comprehensive characterization of the adsorbent was undertaken using techniques such as SEM, EDX, BET, FTIR, XRD, and LIBS. The study delved into varying operational parameters like bed depth (ranging from 3.5 to 9.5 cm) diameter (2.5 cm) and influent flow rate (ranging from 5 to 15mLmin-1). The experimental outcomes revealed that increasing the bed depth and decreasing the influent flow rate significantly bolstered the adsorption column's effectiveness. Breakthrough curves obtained were fitted with different models, including the Thomas and Yoon-Nelson models. The most optimal column performance was achieved with a bed height of 10.5 cm and a flow rate of 5mLmin-1. The combined process achieved removal efficiencies of 94.5% for COD, 97.4% for sulphide, 96.2% for NH3-N, 83.1% for NO3-, 79.3% for PO43-, and 96.9% for Cr(VI) in tannery effluent. This research presents a notable stride toward the development of sustainable and efficient strategies for tannery wastewater treatment.
Collapse
Affiliation(s)
- Kavita Singh
- Centre of Environmental Science, Institute of Interdisciplinary Studies, University of Allahabad, Allahabad, Uttar Pradesh, India.
| | - Bablu Prasad
- Department of Environmental Studies, Faculty of Science, The Maharaja Sayajirao University of Baroda, Vadodara, India.
| | - Abhishek Kumar
- Department of Geology, Faculty of Science, The Maharaja Sayajirao University of Baroda, Vadodara, India.
| | - Madhu Kumari
- Department of Botany, B. R. A. Bihar University, Muzaffarpur, Bihar, India.
| | - Darpan Dubey
- Department of Physics, Faculty of Science, University of Allahabad, Allahabad, Uttar Pradesh, India.
| | - Mika Sillanpää
- Department of Chemical Engineering, School of Mining, Metallurgy and Chemical Engineering, University of Johannesburg, P. O. Box 17011, Doornfontein 2028, South Africa; Functional Materials Group, Gulf University for Science and Technology, Mubarak Al-Abdullah, 32093, Kuwait; School of Technology, Woxsen University, Hyderabad, Telangana, India; Centre of Research Impact and Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Rajpura 140401, Punjab, India; Division of Research & Development, Lovely Professional University, Phagwara 144411, Punjab, India; Adnan Kassar School of Business, Lebanese American University, Beirut, Lebanon.
| | - Kumar Suranjit Prasad
- Centre of Environmental Science, Institute of Interdisciplinary Studies, University of Allahabad, Allahabad, Uttar Pradesh, India.
| |
Collapse
|
4
|
Brião GDV, da Costa TB, Antonelli R, Costa JM. Electrochemical processes for the treatment of contaminant-rich wastewater: A comprehensive review. CHEMOSPHERE 2024; 355:141884. [PMID: 38575083 DOI: 10.1016/j.chemosphere.2024.141884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/22/2024] [Accepted: 04/01/2024] [Indexed: 04/06/2024]
Abstract
Global water demand and environmental concerns related to climate change require industries to develop high-efficiency wastewater treatment methods to remove pollutants. Likewise, toxic pollutants present in wastewater negatively affect the environment and human health, requiring effective treatment. Although conventional treatment processes remove carbon and nutrients, they are insufficient to remove pharmaceuticals, pesticides, and plasticizers. Electrochemical processes effectively remove pollutants from wastewater through the mineralization of non-biodegradable pollutants with consequent conversion into biodegradable compounds. Its advantages include easy operation, versatility, and short reaction time. In this way, this review initially provides a global water scenario with a view to the future. It comprises global demand, treatment methods, and pollution of water resources, addressing various contaminants such as heavy metals, nutrients, organic compounds, and emerging contaminants. Subsequently, the fundamentals of electrochemical treatments are presented as well as electrochemical treatments, highlighting the latest studies involving electrocoagulation, electroflocculation, electroflotation, capacitive deionization and its derivatives, eletrodeionization, and electrochemical advanced oxidation process. Finally, the challenges and perspectives were discussed. In this context, electrochemical processes have proven promising and effective for the treatment of water and wastewater, allowing safe reuse practices and purification with high contaminant removal.
Collapse
Affiliation(s)
- Giani de Vargas Brião
- Center of Research on Science and Technology of BioResources, São Carlos Institute of Chemistry, University of São Paulo, Trabalhador São Carlense Ave, 400, São Carlos 13566-590, SP, Brazil
| | | | - Raissa Antonelli
- Department of Chemical Engineering, University of São Paulo, Prof. Luciano Gualberto Ave, tr. 3, 380, São Paulo 05508-010, SP, Brazil
| | - Josiel Martins Costa
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom.
| |
Collapse
|
5
|
Bockel T, Marre G, Delaruelle G, Agel N, Boissery P, Guilhaumon F, Mouquet N, Mouillot D, Guilbert A, Deter J. Early signals of Posidonia oceanica meadows recovery in a context of wastewater treatment improvements. MARINE POLLUTION BULLETIN 2024; 201:116193. [PMID: 38428047 DOI: 10.1016/j.marpolbul.2024.116193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/21/2024] [Accepted: 02/21/2024] [Indexed: 03/03/2024]
Abstract
Natural ecological restoration is a cornerstone of modern conservation science and managers need more documented "success stories" to lead the way. In French mediterranean sea, we monitored Posidonia oceanica lower limit using acoustic telemetry and photogrammetry and investigated the descriptors driving its variations, at a national scale and over more than a decade. We showed significant effects of environmental descriptors (region, sea surface temperature and bottom temperature) but also of wastewater treatment plant (WWTP) effluents proxies (size of WWTP, time since conformity, and distance to the closest effluent) on the meadows lower limit progression. This work indicates a possible positive response of P. oceanica meadows to improvements in wastewater treatment and a negative effect of high temperatures. While more data is needed, the example of French wastewater policy should inspire stakeholders and coastal managers in their efforts to limit anthropogenic pressures on vulnerable ecosystems.
Collapse
Affiliation(s)
- Thomas Bockel
- Andromède océanologie, 7 place Cassan, Carnon plage, 34130 Mauguio, France; MARBEC, UMR IRD-CNRS-UM-IFREMER 9190, Université Montpellier, 34095 Montpellier Cedex, France.
| | - Guilhem Marre
- Andromède océanologie, 7 place Cassan, Carnon plage, 34130 Mauguio, France
| | | | - Noémie Agel
- Andromède océanologie, 7 place Cassan, Carnon plage, 34130 Mauguio, France
| | - Pierre Boissery
- Agence de l'Eau Rhône-Méditerranée-Corse, Délégation de Marseille, immeuble CMCI, 2 rue Henri Barbusse, CS 90464, 13207 Marseille Cedex 01, France
| | - François Guilhaumon
- MARBEC, UMR IRD-CNRS-UM-IFREMER 9190, Université Montpellier, 34095 Montpellier Cedex, France
| | - Nicolas Mouquet
- MARBEC, UMR IRD-CNRS-UM-IFREMER 9190, Université Montpellier, 34095 Montpellier Cedex, France; FRB - CESAB, Institut Bouisson Bertrand, 5, rue de l'École de médecine, 34000 Montpellier, France
| | - David Mouillot
- MARBEC, UMR IRD-CNRS-UM-IFREMER 9190, Université Montpellier, 34095 Montpellier Cedex, France
| | - Antonin Guilbert
- Andromède océanologie, 7 place Cassan, Carnon plage, 34130 Mauguio, France
| | - Julie Deter
- Andromède océanologie, 7 place Cassan, Carnon plage, 34130 Mauguio, France; MARBEC, UMR IRD-CNRS-UM-IFREMER 9190, Université Montpellier, 34095 Montpellier Cedex, France
| |
Collapse
|
6
|
Sandoval MA, Coreño O, García V, Salazar-González R. Enhancing industrial swine slaughterhouse wastewater treatment: Optimization of electrocoagulation technique and operating mode. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 349:119556. [PMID: 37984271 DOI: 10.1016/j.jenvman.2023.119556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 10/30/2023] [Accepted: 11/04/2023] [Indexed: 11/22/2023]
Abstract
In this study, industrial swine slaughterhouse effluents were treated by an electrocoagulation process (EC) with aluminum and iron electrodes. Batch and semicontinuous operation were performed. EC tests were carried out in batch operating mode for 2.5 h using fixed current densities (j = 10, 20, and 30 mA cm-2) in sulfate and chloride media. At the laboratory scale, higher TOC removal efficiencies were observed using aluminum electrodes at 20 mA cm-2 without the addition of a supporting electrolyte (82.7%). However, the EC process with Fe electrodes consumed 43.6% less energy. After the best operating parameters were found at the laboratory scale, the process was tested as a semicontinuous prepilot process using a filter-press FM01-LC-type electrochemical reactor equipped with flat plate aluminum electrodes. In this stage, current densities and mean linear flow rates were assessed. The highest TOC removal efficiency of 72.7% (i.e., residual TOC concentration of 85.18 mg L-1) in the semicontinuous process was achieved by the application of j = 25 mA cm-2 and ur = 0.64 cm s-1 with an energy consumption of 19.80 kW h m-3. The residual COD and TP concentrations met the international standard limits. Moreover, complete decoloration and disinfection were accomplished. EDXRF, SEM, EDAX, XRD, and FTIR analyses indicated that pollutants were removed by adsorption on aluminum/iron hydroxides/oxyhydroxides.
Collapse
Affiliation(s)
- Miguel A Sandoval
- Instituto Tecnológico Superior de Guanajuato, Tecnológico Nacional de México, Carretera Estatal Guanajuato-Puentecillas km. 10.5, 36262, Guanajuato, Guanajuato, Mexico; Departamento de Ingeniería Química, Universidad de Guanajuato, Noria Alta S/N, 36050, Guanajuato, Guanajuato, Mexico.
| | - Oscar Coreño
- Departamento de Ingeniería Civil, Universidad de Guanajuato, Av. Juárez 77, Zona Centro, 36000, Guanajuato, Guanajuato, Mexico
| | - Verónica García
- Centro de Estudios en Ciencia y Tecnología de Alimentos (CECTA), Universidad de Santiago de Chile, USACH, Casilla 40, Correo 33, Santiago, Chile
| | - Ricardo Salazar-González
- Analysis, Treatment, Electrochemistry, Recovery and Reuse of Water Research Group, WATER(2), Department of Inorganic Chemistry, Faculty of Chemistry and Pharmacy, Pontificia Universidad Católica de Chile, Chile.
| |
Collapse
|
7
|
Sari Erkan H, Bakaraki Turan N. Effects of hydrogen peroxide and calcium hypochlorite on chemical oxygen demand solubilization and disintegration of waste activated sludge by electro-chemical pretreatment. ENVIRONMENTAL TECHNOLOGY 2024; 45:508-522. [PMID: 35993109 DOI: 10.1080/09593330.2022.2114856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 08/03/2022] [Indexed: 05/16/2023]
Abstract
ABSTRACTThe combination of electrochemical (EC) pretreatment with hydrogen peroxide (HP) and calcium hypochlorite (CHC) was investigated in this study for their effect on soluble chemical oxygen demand (CODs) and disintegration degree (DD) of waste activated sludge (WAS). For this aim, response surface methodology (RSM) and Box-Behnken design (BBD) were applied the determination of the optimum operational conditions. Operational conditions were varied between 0.2 and 2.0 mmol/g SS for HP and CHC dosages, 1-5 A for the applied current, 2-10 for the initial pH, and 15-45 min for the treatment time. Obtained results for each treatment were accurate and significant with correlation coefficients (R2) of 0.8639% and 0.9189% for EC combined with HP pretreatment and EC combined with CHC pretreatment, respectively. According to the obtained results, CODs increased in comparison to the raw sludge (168 mg/L) noting that CODs for EC - CHC (1155 ± 21 mg/L) was higher than EC - HP (811.5 ± 15 mg/L) at optimized conditions (for EC-HP pretreatment: HP dosage: 0.34 mmol/g TSS, Applied current:5 A, Initial pH:10, Time: 45 min, For EC-CHC pretreatment: CHC dosage: 0.23 mmol/g TSS, Applied current:4.83 A, Initial pH:10, Time: 40 min). Besides, the DD in terms of COD, total nitrogen (TN) and total organic carbon (TOC) (DDCOD, DDTN and DDTOC) registered increased values after the application of the EC treatment with both oxidants. The highest DDCOD, DDTN and DDTOC values were obtained with EC-CHC pretreatment for 11.34%, 20.34% and 9.18% respectively compared to EC-HP pretreatment (DDCOD: 7.37%, DDTN: 15.18% and DDTOC: 6.94%).
Collapse
Affiliation(s)
- Hanife Sari Erkan
- Civil Engineering Faculty, Environmental Engineering Department, Yildiz Technical University, Istanbul, Turkey
| | - Nouha Bakaraki Turan
- Civil Engineering Faculty, Environmental Engineering Department, Yildiz Technical University, Istanbul, Turkey
| |
Collapse
|
8
|
Nisa TU, Khokhar WA, Imran U, Khokhar SA, Soomro N. Electrochemical treatment of wastewater containing urea-formaldehyde and melamine-formaldehyde. CHEMOSPHERE 2023; 338:139587. [PMID: 37479002 DOI: 10.1016/j.chemosphere.2023.139587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 06/29/2023] [Accepted: 07/18/2023] [Indexed: 07/23/2023]
Abstract
The wastewater containing urea-formaldehyde (UF) and melamine-formaldehyde (MF) from the medium-density fiberboard (MDF) lamination factory disposed into the waterbodies adversely affects human health and aquatic life. Therefore, its treatment before discharge is necessary. Researchers have used various techniques to treat this type of wastewater in the past, but none have tried electrochemical (EC). However, EC can potentially remove pollutants such as chemical oxygen demand (COD), total organic carbon (TOC), formaldehyde (FA), total nitrogen (TN), nitrogen nitrate (NO3-N), and other hydrocarbons. Hence, this study uses the EC technique to treat wastewater containing UF and MF with aluminium electrodes. The experiments were run in batch mode with a 250 mL working volume in a 500 mL Pyrex glass beaker using a variable DC power supply (0-30 V and 0-5 A). The impacts of various parameters, including reaction time (RT) 30-240 min, current density (CD) 8.66-51.94 mA/cm2, inter-electrode distance (IED) 1-2 cm, and mixing speed in the range of 60-120 rpm were examined to achieve the best pollutant removals. The best removal percentage was reached at the optimized conditions of 150 min RT, 43.28 mA/cm2 CD, 1.5 cm IED, and 80 rpm: 81.1% TOC, 61.5% COD, 76.7% TN, 28.3% NO3-N, and 55.2% FA. During the EC process, electrodes and energy consumption were estimated at around 2.367 (g/L) and 0.18 (kWh/L), respectively. A kinetic analysis was also carried out to determine the pollutant's removal trend. This study concluded that the pseudo-first-order kinetic model was the best fit for removing TOC and FA with regression coefficients of 0.96 and 0.83, respectively.
Collapse
Affiliation(s)
- Tamt Ul Nisa
- US - Pakistan Center for Advanced Studies in Water, Mehran University of Engineering and Technology (USPCAS-W), Jamshoro, 76062, Sindh, Pakistan.
| | - Waheed Ali Khokhar
- US - Pakistan Center for Advanced Studies in Water, Mehran University of Engineering and Technology (USPCAS-W), Jamshoro, 76062, Sindh, Pakistan.
| | - Uzma Imran
- US - Pakistan Center for Advanced Studies in Water, Mehran University of Engineering and Technology (USPCAS-W), Jamshoro, 76062, Sindh, Pakistan.
| | - Shakir Ali Khokhar
- US - Pakistan Center for Advanced Studies in Water, Mehran University of Engineering and Technology (USPCAS-W), Jamshoro, 76062, Sindh, Pakistan
| | - Nayab Soomro
- Department of Textile Engineering, Mehran University of Engineering and Technology, Jamshoro, 76062, Sindh, Pakistan
| |
Collapse
|
9
|
Belli TJ, Bassin JP, de Sousa Vidal CM, Hassemer MEN, Rodrigues C, Lapolli FR. Effects of solid retention time and exposure mode to electric current on Remazol Brilliant Violet removal in an electro-membrane bioreactor. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:58412-58427. [PMID: 36991202 DOI: 10.1007/s11356-023-26593-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 03/18/2023] [Indexed: 05/10/2023]
Abstract
The performance of an electrochemically assisted anoxic-oxic membrane bioreactor (A/O-eMBR) was assessed as an alternative for azo dye (Remazol Brilhant Violet (RBV)) removal from simulated textile wastewater. The A/O-eMBR was operated under three experimental conditions (runs I, II, and III), in which different solids retention time (SRT) (45 and 20 d) and exposure mode to electric current (6'ON/30'OFF and 6'ON/12'OFF) were assessed. The reactor exhibited excellent decolorization performance for all runs, with average dye removal efficiency ranging from 94.3 to 98.2%. Activity batch assays showed that the dye removal rate (DRR) decreased from 16.8 to 10.2 mg RBV L-1 h-1 when the SRT was reduced from 45 to 20 d, likely attributed to the lower biomass content under lower sludge age. At the electric current exposure mode of 6' ON/12'OFF, a more substantial decrease of DRR to 1.5 mg RBV L-1 h-1 was noticed, suggesting a possible inhibitory effect on dye removal via biodegradation. By reducing the SRT to 20 d, a worse mixed liquor filterability condition was observed, with a membrane fouling rate (MFR) of 0.979 kPa d-1. In contrast, using the electric current exposure mode of 6'ON/12'OFF resulted in lower membrane fouling propensity, with an MFR of 0.333 kPa d-1. A more attractive cost-benefit ratio for dye removal was obtained using the exposure mode of 6'ON/30'OFF, for which the energy demand was estimated at 21.9-22.6 kWh kg dye-1 removed, almost two times lower than that observed for the mode of 6'ON/12'OFF.
Collapse
Affiliation(s)
- Tiago José Belli
- Civil Engineering Department, Santa Catarina State University, Ibirama, SC, ZIP 89140-000, Brazil.
| | - João Paulo Bassin
- Chemical Engineering Program, COPPE, Federal University of Rio de Janeiro, P.O. Box 68502, Rio de Janeiro, RJ, 21941-972, Brazil
| | - Carlos Magno de Sousa Vidal
- Environmental and Sanitary Engineering Department, State University of Centro-Oeste (UNICENTRO), PR 153, Km 07, Riozinho, P.O. Box 21, Irati, PR, Brazil
| | - Maria Eliza Nagel Hassemer
- Environmental Engineering Program, PPGEA, Federal University of Santa Catarina, P.O. Box 476, Florianópolis, SC, ZIP 88040-900, Brazil
| | - Caroline Rodrigues
- Environmental Engineering Program, PPGEA, Federal University of Santa Catarina, P.O. Box 476, Florianópolis, SC, ZIP 88040-900, Brazil
| | - Flávio Rubens Lapolli
- Environmental Engineering Program, PPGEA, Federal University of Santa Catarina, P.O. Box 476, Florianópolis, SC, ZIP 88040-900, Brazil
| |
Collapse
|
10
|
Zhang M, Tan X, Ding W, Jiang Z, He K, Zhao B, Takeuchi H, Huang Y. Aluminum-based electrocoagulation for residual fluoride removal during per- and polyfluoroalkyl substances (PFASs) wastewater treatment. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.122989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
11
|
Kosgey K, Zungu PV, Bux F, Kumari S. Biological nitrogen removal from low carbon wastewater. Front Microbiol 2022; 13:968812. [PMID: 36466689 PMCID: PMC9709150 DOI: 10.3389/fmicb.2022.968812] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 10/28/2022] [Indexed: 08/13/2023] Open
Abstract
Nitrogen has traditionally been removed from wastewater by nitrification and denitrification processes, in which organic carbon has been used as an electron donor during denitrification. However, some wastewaters contain low concentrations of organic carbon, which may require external organic carbon supply, increasing treatment costs. As a result, processes such as partial nitrification/anammox (anaerobic ammonium oxidation) (PN/A), autotrophic denitrification, nitritation-denitritation and bioelectrochemical processes have been studied as possible alternatives, and are thus evaluated in this study based on process kinetics, applicability at large-scale and process configuration. Oxygen demand for nitritation-denitritation and PN/A is 25% and 60% lower than for nitrification/denitrification, respectively. In addition, PN/A process does not require organic carbon supply, while its supply for nitritation-denitritation is 40% less than for nitrification/denitrification. Both PN/A and nitritation-denitritation produce less sludge compared to nitrification/denitrification, which saves on sludge handling costs. Similarly, autotrophic denitrification generates less sludge compared to heterotrophic denitrification and could save on sludge handling costs. However, autotrophic denitrification driven by metallic ions, elemental sulfur (S) and its compounds could generate harmful chemicals. On the other hand, hydrogenotrophic denitrification can remove nitrogen completely without generation of harmful chemicals, but requires specialized equipment for generation and handling of hydrogen gas (H2), which complicates process configuration. Bioelectrochemical processes are limited by low kinetics and complicated process configuration. In sum, anammox-mediated processes represent the best alternative to nitrification/denitrification for nitrogen removal in low- and high-strength wastewaters.
Collapse
Affiliation(s)
- Kiprotich Kosgey
- Institute for Water and Wastewater Technology, Durban University of Technology, Durban, South Africa
| | | | | | - Sheena Kumari
- Institute for Water and Wastewater Technology, Durban University of Technology, Durban, South Africa
| |
Collapse
|
12
|
Yasasve M, Manjusha M, Manojj D, Hariharan NM, Sai Preethi P, Asaithambi P, Karmegam N, Saravanan M. Unravelling the emerging carcinogenic contaminants from industrial waste water for prospective remediation by electrocoagulation - A review. CHEMOSPHERE 2022; 307:136017. [PMID: 35977566 DOI: 10.1016/j.chemosphere.2022.136017] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 07/16/2022] [Accepted: 08/07/2022] [Indexed: 06/15/2023]
Abstract
The need of the hour relies on finding new but sustainable ways to curb rising pollution levels. The accelerated levels of urbanization and increase in population deplete the finite resources essential for human sustenance. In this aspect, water is one of the non-renewable sources that is running out very fast and is polluted drastically day by day. One way of tackling the problem is to reduce the pollution levels by decreasing the usage of chemicals in the process, and the other is to find ways to reuse or reduce the contaminants in the effluent by treatment methods. Most of the available water recycling or treatment methods are not sustainable. Some of them even use toxic chemicals in the processing steps. Treatment of organic wastes from industries is a challenging task as they are hard to remove. Electrocoagulation is one of the emerging water treatment technologies that is highly sustainable and has a comparatively cheaper operating cost. Being a broad-spectrum treatment process, it is suitable for treating the most common water pollutants ranging from oils, bacteria, heavy metals, and others. The process is also straightforward, where electrical current is used to coagulate the contaminates. The presence of carcinogens in these waste water increases the need for its treatment towards further use. The present investigation is made as an extensive analysis of the emerging carcinogens and their various sources from process industries, especially in the form of organic waste and their removal by electrocoagulation and its coupled techniques. The paper also aims to ascertain why the electrocoagulation technique may be a better alternative compared with other methods for the removal of carcinogens in organic wastewater, an analysis which has not been explored before.
Collapse
Affiliation(s)
- Madhavan Yasasve
- Department of Biotechnology, Sree Sastha Institute of Engineering and Technology (Affiliated to Anna University), Chembarambakkam, Chennai, 600123, Tamil Nadu, India
| | - Muralidharan Manjusha
- Department of Genetic Engineering, School of Bioengineering, SRM University, Kattankulathur, 603203, Tamil Nadu, India
| | - Dhinakaran Manojj
- Department of Biotechnology, Sree Sastha Institute of Engineering and Technology (Affiliated to Anna University), Chembarambakkam, Chennai, 600123, Tamil Nadu, India
| | - N M Hariharan
- Department of Biotechnology, Sree Sastha Institute of Engineering and Technology (Affiliated to Anna University), Chembarambakkam, Chennai, 600123, Tamil Nadu, India.
| | - P Sai Preethi
- Department of Biotechnology, Sree Sastha Institute of Engineering and Technology (Affiliated to Anna University), Chembarambakkam, Chennai, 600123, Tamil Nadu, India
| | - Perumal Asaithambi
- Faculty of Civil and Environmental Engineering, Jimma Institute of Technology, Jimma University, Jimma, Po Box - 378, Ethiopia
| | - Natchimuthu Karmegam
- Department of Botany, Government Arts College (Autonomous), Salem, 636007, Tamil Nadu, India
| | - Muthupandian Saravanan
- AMR and Nanomedicine Laboratory, Department of Pharmacology, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai, 600077, Tamil Nadu, India.
| |
Collapse
|
13
|
Ashoori R, Samaei MR, Yousefinejad S, Azhdarpoor A, Emadi Z, Mohammadpour A, Lari AR, Mousavi Khaneghah A. Simultaneous removal of fluoride and nitrate from synthetic aqueous solution and groundwater by the electrochemical process using non-coated and coated anode electrodes: A human health risk study. ENVIRONMENTAL RESEARCH 2022; 214:113938. [PMID: 35977584 DOI: 10.1016/j.envres.2022.113938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 07/10/2022] [Accepted: 07/18/2022] [Indexed: 06/15/2023]
Abstract
Co-presence of fluoride (F-) and nitrate (NO3-) in water causes numerous health complications. Thus, they should be eliminated by an appropriate method like the EC process. In this research, simultaneous removal of F- and NO3- from synthetic aqueous solution and groundwater has been considered by the EC technique under operational parameters like anode materials (un-coated (Al and Fe) and synthesized coated (Ti/TiRuSnO2 and Ti/PbO2)), cathode materials (Cu, St, and Gr), current density (12, 24, and 36 mA/cm2), inter-electrode distance (0.5, 1, and 2 cm), pH (5.5, 7, and 8.5), NaCl concentrations (0.5, 1, and 1.5 g/L), electrolysis time (15, 30, 45, 60, 90, and 120 min), NO3- concentrations (75, 150, and 225 mg/L), and F- concentrations (2, 4, 6, and 8 mg/L) for the first time in this research. The results proved that Al as non-coated anode and Cu as cathode electrodes were more effective in the co-removal of F- and NO3-. The maximum removal efficiencies of 94.19 and 95% were observed at the current density of 36 mA/cm2, 1 cm of inter-electrode distance, pH 7, 1 g/L of NaCl, and 90 min electrolysis time by Al-Cu electrode for F- (2 mg/L) and NO3- (75 mg/L), respectively. The higher efficiency of Al-Cu electrodes was due to the simultaneous occurrence of electrocoagulation, electroreduction, and electrooxidation processes. Al-Cu electrode application considerably diminished f- and NO3- concentrations in the groundwater. Health risk assessment proved that HQ of F- was significantly decreased after treatment by the Al-Cu electrode. Thus, the EC process using an appropriate and effective electrode is a promising technique for treating aqueous solutions containing F- and NO3-.
Collapse
Affiliation(s)
- Razieh Ashoori
- Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Reza Samaei
- Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Saeed Yousefinejad
- Research Center for Health Sciences, Institute of Health, Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Abooalfazl Azhdarpoor
- Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Zahra Emadi
- Department of Environmental Health Engineering, School of Health, Shahrekord University of Medical Sciences, Shahrekord, Iran
| | - Amin Mohammadpour
- Department of Chemical Engineering, School of Chemical and Petroleum Engineering, Shiraz University, 71946-84636 Shiraz, Iran
| | - Ali Rasti Lari
- School of Civil and Environmental Engineering, University of Technology Sydney, 15 Broadway, NSW, 2007, Australia
| | - Amin Mousavi Khaneghah
- Department of Fruit and Vegetable Product Technology, Prof. Wacław Dąbrowski Institute of Agricultural and Food Biotechnology - State Research Institute, 36 Rakowiecka St., 02-532, Warsaw, Poland.
| |
Collapse
|
14
|
Mousazadeh M, Kabdaşlı I, Khademi S, Sandoval MA, Moussavi SP, Malekdar F, Gilhotra V, Hashemi M, Dehghani MH. A critical review on the existing wastewater treatment methods in the COVID-19 era: What is the potential of advanced oxidation processes in combatting viral especially SARS-CoV-2? JOURNAL OF WATER PROCESS ENGINEERING 2022; 49:103077. [PMID: 35990175 PMCID: PMC9381433 DOI: 10.1016/j.jwpe.2022.103077] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/19/2022] [Accepted: 08/15/2022] [Indexed: 06/01/2023]
Abstract
The COVID-19 epidemic has put the risk of virus contamination in water bodies on the horizon of health authorities. Hence, finding effective ways to remove the virus, especially SARS-CoV-2, from wastewater treatment plants (WWTPs) has emerged as a hot issue in the last few years. Herein, this study first deals with the fate of SARS-CoV-2 genetic material in WWTPs, then critically reviews and compares different wastewater treatment methods for combatting COVID-19 as well as to increase the water quality. This critical review sheds light the efficiency of advanced oxidation processes (AOPs) to inactivate virus, specially SARS-CoV-2 RNA. Although several physicochemical treatment processes (e.g. activated sludge) are commonly used to eliminate pathogens, AOPs are the most versatile and effective virus inactivation methods. For instance, TiO2 is the most known and widely studied photo-catalyst innocuously utilized to degrade pollutants as well as to photo-induce bacterial and virus disinfection due to its high chemical resistance and efficient photo-activity. When ozone is dissolved in water and wastewater, it generates a wide spectrum of the reactive oxygen species (ROS), which are responsible to degrade materials in virus membranes resulting in destroying the cell wall. Furthermore, electrochemical advanced oxidation processes act through direct oxidation when pathogens react at the anode surface or by indirect oxidation through oxidizing species produced in the bulk solution. Consequently, they represent a feasible choice for the inactivation of a wide range of pathogens. Nonetheless, there are some challenges with AOPs which should be addressed for application at industrial-scale.
Collapse
Affiliation(s)
- Milad Mousazadeh
- Social Determinants of Health Research Center, Research Institute for Prevention of Non-Communicable Diseases, Qazvin University of Medical Sciences, Qazvin, Iran
- Department of Environmental Health Engineering, School of Health, Qazvin University of Medical Sciences, Qazvin, Iran
| | - Işık Kabdaşlı
- İstanbul Technical University, Civil Engineering Faculty, Environmental Engineering Department, Ayazağa Campus, 34469 Maslak, İstanbul, Turkey
| | - Sara Khademi
- Health, Safety, and Environment Specialist, North Drilling Company, Ahvaz, Iran
| | - Miguel Angel Sandoval
- Universidad de Santiago de Chile USACH, Facultad de Química y Biología, Departamento de Química de los Materiales, Laboratorio de Electroquímica Medio Ambiental, LEQMA, Casilla 40, Correo 33, Santiago, Chile
- Universidad de Guanajuato, División de Ciencias Naturales y Exactas, Departamento de Ingeniería Química, Noria Alta S/N, 36050, Guanajuato, Guanajuato, Mexico
| | | | - Fatemeh Malekdar
- Department of Foot and Mouth Disease Vaccine Production, Razi Vaccine and Serum Research Institute, Karaj, Iran
| | - Vishakha Gilhotra
- Department of Botanical and Environmental Sciences, Guru Nanak Dev University, Amritsar, Punjab, India
| | - Marjan Hashemi
- Environmental and Occupational Hazards Control Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mohammad Hadi Dehghani
- Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
- Institute for Environmental Research, Center for Solid Waste Research, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
15
|
Crispim AC, de Araújo DM, Martínez-Huitle CA, Souza FL, Dos Santos EV. Application of electro-Fenton and photoelectro-Fenton processes for the degradation of contaminants in landfill leachate. ENVIRONMENTAL RESEARCH 2022; 213:113552. [PMID: 35710024 DOI: 10.1016/j.envres.2022.113552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 05/16/2022] [Accepted: 05/19/2022] [Indexed: 06/15/2023]
Abstract
Worldwide, most solid waste ends its life in landfill sites, which have a significant environmental impact in several respects. In particular, rainfall over landfill sites results in the production of an aqueous leachate containing compounds having low biodegradability, high toxicity, and a high organic load. For this reason, this study aims to investigate the applicability of electro-Fenton (EF) and photoelectro-Fenton (PEF) processes as alternative for treating a local landfill effluent with high organic content (chemical oxygen demand (COD) = 2684.7 mg-O2 L -1) in a continuous-flow reactor (using, for first time, this kind of system with higher electrodes area of 35 cm2) using boron-doped diamond anode (Nb/BDD) and a carbon felt cathode (FC) electrodes. The effects of current density j (30, 60 and 90 mA cm-2) and UV radiation wavelength (UVA and UVC) were studied to evaluate the treatment efficiency as well as the energy consumption. Results clearly showed that, the best efficiencies removing organic matter, in terms of COD, were about 66%, 68% and 89% with an energy consumption of only 19.41, 17.61 and 17.59 kWh kg COD-1 for EF, PEF-UVA and PEF-UVC respectively, at 90 mA cm-2 after 4 h of operation. The treatment of this kind of effluent produced organic and inorganic by-products, the acetic and formic acids as well as NO2-, NO3-, and NH4+, being assessed their concentrations.
Collapse
Affiliation(s)
- Alana C Crispim
- Laboratório de Eletroquímica Ambiental e Aplicada, Instituto de Química, Universidade Federal Do Rio Grande Do Norte, Lagoa Nova, CEP 59.072-900, RN, Brazil
| | - Danyelle M de Araújo
- Laboratório de Eletroquímica Ambiental e Aplicada, Instituto de Química, Universidade Federal Do Rio Grande Do Norte, Lagoa Nova, CEP 59.072-900, RN, Brazil
| | - Carlos A Martínez-Huitle
- Laboratório de Eletroquímica Ambiental e Aplicada, Instituto de Química, Universidade Federal Do Rio Grande Do Norte, Lagoa Nova, CEP 59.072-900, RN, Brazil; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, UNESP, P.O. Box 355, 14800 900, Araraquara, SP, Brazil
| | - Fernanda L Souza
- National Nanotechnology Laboratory for Agriculture, Brazilian Agriculture Research Corporation (Embrapa), XV de Novembro Street, 1452, São Carlos, Brazil.
| | - Elisama V Dos Santos
- Laboratório de Eletroquímica Ambiental e Aplicada, Instituto de Química, Universidade Federal Do Rio Grande Do Norte, Lagoa Nova, CEP 59.072-900, RN, Brazil; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, UNESP, P.O. Box 355, 14800 900, Araraquara, SP, Brazil.
| |
Collapse
|
16
|
Gong C, Zhang J, Ren X, He C, Han J, Zhang Z. A comparative study of electrocoagulation treatment with iron, aluminum and zinc electrodes for selenium removal from flour production wastewater. CHEMOSPHERE 2022; 303:135249. [PMID: 35691397 DOI: 10.1016/j.chemosphere.2022.135249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 05/20/2022] [Accepted: 06/03/2022] [Indexed: 06/15/2023]
Abstract
Electrocoagulation (EC) using iron (Fe), zinc (Zn) and aluminum (Al) electrodes was comparatively applied in the treatment of selenium (Se) in flour production (FP) wastewater. It was indicated that EC treatment with Fe anode obtained highest removal efficiency (79.1%) for Se in the 90 min treatment in the comparative study, which could be attributed to the superior adsorption capacity of in-situ generated iron flocs. Removal of Se resulted from electrodeposition and adsorption to in-situ generated flocs in EC treatment, and the operational conditions significantly influenced the Se removal performance in this work. The results showed the acidic condition and higher current density favored EC treatment on Se removal, EC removed up to 97.8% of Se at pH 4 under 15 mA cm-2, whereas it obtained 83.5% and 50.4% of removal efficiency at pH 7 and 10, respectively. There was competitive adsorption in the process of selenium removal, as the in-situ generated flocs effectively removed 35.6% of humic acid-like (HA-like) substance in FP wastewater after 90 min treatment. The FTIR results showed that HA-like substance mainly contained the protein water hydrogen bond, carboxylate COO antisymmetric stretching and other functional groups. Through the analysis of existence of Se in flocs and wastewater, it can be found that approximately 2.8%-3.92% of Se was removed by electrodeposition process. This study illustrated the Se removal mechanism and provided constructive suggestion for food manufacturing to the metal removal and utilization of advanced treatment.
Collapse
Affiliation(s)
- Chenhao Gong
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China.
| | - Jian Zhang
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China
| | - Xiaojing Ren
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China
| | - Can He
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China
| | - Junxing Han
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China
| | - Zhongguo Zhang
- Institute of Resource and Environment, Beijing Academy of Science and Technology, No. 1 Gao Li Zhang Road, Beijing, 100095, China.
| |
Collapse
|
17
|
Wastewater Treatment Using a Photoelectrochemical Oxidation Process for the Coffee Processing Industry Optimization of Chemical Oxygen Demand (COD) Removal Using Response Surface Methodology. Int J Anal Chem 2022; 2022:1734411. [PMID: 35959445 PMCID: PMC9357802 DOI: 10.1155/2022/1734411] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 05/19/2022] [Accepted: 07/05/2022] [Indexed: 12/07/2022] Open
Abstract
The elimination of organic compounds in coffee processing effluent utilizing electrochemical oxidation (ECO) as well as a combination of electrochemical oxidation (ECO) and ultraviolet and hydrogen peroxide (UV/H2O2) was explored. Then, the percentage reduction of chemical oxygen demand (COD) was investigated. The effect of different experimental factors such as solution pH, sodium chloride (NaCl) concentration, calcium chloride (CaCl2) concentration, electric current, electrolysis duration, and hydrogen peroxide dosage on the percent removal efficiency of the hybrid electrochemical oxidation (ECO) with the ultraviolet and hydrogen peroxide (UV/H2O2) process has been investigated. The response surface methodology (RSM) based on central composite design (CCD) was used to organize the trial runs and optimize the results. The hybrid electrochemical oxidation (ECO) with the ultraviolet and hydrogen peroxide (UV/H2O2) process removed 99.61% of the chemical oxygen demand (COD) with a low power usage of 1.12 kWh/m3 compared to the other procedures, according to the experimental data analysis. These findings were obtained with a pH of 7, a current of 0.40 A, 1.5 g of CaCl2, and a total electrolysis period of 40 minutes. When it came to eliminating organic compounds from coffee manufacturing effluent, CaCl2 outperformed NaCl. Analysis of variance (ANOVA) with 95% confidence limits was used to examine the significance of independent variables and their interactions.
Collapse
|
18
|
Zampeta C, Mastrantonaki M, Katsaouni N, Frontistis Z, Koutsoukos PG, Vayenas DV. Treatment of printing ink wastewater using a continuous flow electrocoagulation reactor. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 314:115033. [PMID: 35427942 DOI: 10.1016/j.jenvman.2022.115033] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 03/31/2022] [Accepted: 04/05/2022] [Indexed: 06/14/2023]
Abstract
Printing ink wastewater from printing facilities is difficult to treat because of its heavy pollutant load (chemical oxygen demand - COD, color and total suspended solids - TSS). In this study undiluted printing ink wastewater with high COD (i.e., 20,000 mgL-1) was treated using a highly efficient, continuous flow electrocoagulation reactor with aluminum electrodes. The parameters investigated were: initial COD concentration (4000, 10,000 and 20,000 mgL-1), current density (21, 42 and 83 mAcm-2), and inlet flow rate (6, 8 and 10 mLmin-1). All parameters showed great efficiency in terms of pollutant removal for diluted printing ink wastewater. For undiluted printing ink wastewater treatment, COD, color, and TSS removal were maximized at 6 mLmin-1 flow rate reaching 82%, 98%, and 85% COD, color, and TSS removal, respectively, by applying the lower tested current density 21 mAcm-2. COD, color and TSS removal increased with increasing current density. For undiluted printing ink wastewater and a flow rate of 8 mLmin-1, COD removal was between 42 and 88%, color reduction between 85 and 99%, and TSS reduction between 83 and 98% when the applied current was increased (from 21 to 83 mAcm-2). Lower pollutant removal was observed at the highest flow rate of 10 mLmin-1 for all current densities tested. Process cost calculations in terms of electrical energy, electrode material consumption and sludge disposal, showed that the use of continuous flow electrocoagulation reactor (with flow rate 6 mLmin-1, and at 21 mAcm-2) is an affordable and effective treatment method for printing ink wastewater streams with very high COD. Sludge characterization showed Al-silicate-rich sludge. Particle sizes increased after treatment and Cu and Ti were detected in the sludge. A post-treatment stage is necessary before discharging effluent into water bodies.
Collapse
Affiliation(s)
- Charikleia Zampeta
- Department of Chemical Engineering, University of Patras, Rio, GR-26504 Patras, Greece.
| | - Maria Mastrantonaki
- Department of Chemical Engineering, University of Patras, Rio, GR-26504 Patras, Greece.
| | - Niki Katsaouni
- Department of Chemical Engineering, University of Patras, Rio, GR-26504 Patras, Greece.
| | - Zacharias Frontistis
- Department of Chemical Engineering, University of Western Macedonia, GR-50100, Kozani, Greece.
| | - P G Koutsoukos
- Department of Chemical Engineering, University of Patras, Rio, GR-26504 Patras, Greece; Institute of Chemical Engineering and High Temperature Chemical Processes (FORTH/ICE-HT), Stadiou Str., Platani, GR-26504, Patras, Greece.
| | - Dimitris V Vayenas
- Department of Chemical Engineering, University of Patras, Rio, GR-26504 Patras, Greece; Institute of Chemical Engineering and High Temperature Chemical Processes (FORTH/ICE-HT), Stadiou Str., Platani, GR-26504, Patras, Greece.
| |
Collapse
|
19
|
Das PP, Sharma M, Purkait MK. Recent progress on electrocoagulation process for wastewater treatment: A review. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
20
|
Sustainable vs. Conventional Approach for Olive Oil Wastewater Management: A Review of the State of the Art. WATER 2022. [DOI: 10.3390/w14111695] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The main goal of this review is to collect and analyze the recently published research concerning the conventional and sustainable treatment processes for olive mill wastewater (OMW). In the conventional treatment processes, it is noticed that the main objective is to meet the environmental regulations for remediated wastewater without considering the economical values of its valuable constituents such as polyphenols. These substances have many important environmental values and could be used in many vital applications. Conversely, sustainable treatment processes aim to recover the valuable constituents through different processes and then treat the residual wastewater. Both approaches’ operational and design parameters were analyzed to generalize their advantages and possible applications. A valorization-treatment approach for OMW is expected to make it a sustainable resource for ingredients of high economical value that could lead to a profitable business. In addition, inclusion of a recovery process will detoxify the residual OMW, simplify its management treatment, and allow the possible reuse of the vast amounts of processed water. In a nutshell, the proposed approach led to zero waste with a closed water cycle development.
Collapse
|
21
|
Some Well-Known Alginate and Chitosan Modifications Used in Adsorption: A Review. WATER 2022. [DOI: 10.3390/w14091353] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Owing to environmental pollution and increasingly strict regulations, heavy metals have attracted the attention of many researchers in various disciplines. Alginate and chitosan derivatives have gained popularity as biosorbents for water treatment. An increase in the number of publications on modified biosorbents for the biosorption of toxic compounds reveals widespread interest in examining the requirements and positive contribution of each modification type. This paper reviews the advantages and disadvantages of using alginate and chitosan for adsorption. Well-known modifications based on chitosan and alginate, namely, grafting, functionalization, copolymerization and cross-linking, as well as applications in the field of adsorption processes, especially amino acid functionalization, are reviewed. The selection criteria for the best biosorbents and their effectiveness and proposed mechanism of adsorption are discussed critically. In the conclusion, the question of why these adsorbents need modification before use is addressed.
Collapse
|
22
|
Comparison Study on Sonodirect and Sonoalternate Current Electrocoagulation Process for Domestic Wastewater Treatment. Int J Anal Chem 2022; 2022:3477995. [PMID: 35340980 PMCID: PMC8942696 DOI: 10.1155/2022/3477995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 01/20/2022] [Accepted: 02/22/2022] [Indexed: 11/17/2022] Open
Abstract
Nowadays, there is a problem related to wastewater handling which is released from different activities. The electrocoagulation method has been a dominant treatment method for wastewater treatment. There are different forms of electrocoagulation methods for wastewater treatment. Nevertheless, there was no comparison made for the removal efficiency of the sonoalternate current (SAC), alternate current (AC), sonodirect current (SDC), and direct current (DC) electrocoagulation process. The efficiency of electrocoagulation methods was compared for their removal of chemical oxygen demand (COD) from Jimma University domestic wastewater. Batch Reactor DC/AC electrocoagulation cell was used to determine the removal efficiency. During the comparison, the response surface methodology (RSM) was used to analyze and optimize the data taken from the laboratory. Besides, ANOVA was used to analyze the interaction effects of different parameters. The removal of COD from domestic wastewater was achieved with DCE, ACE, SDCE, and SACE which were 82.6%, 86.58%, 88.6%, and 92.5%, respectively, under optimal experimental conditions. From the finding, SACE was more successful at removing % COD than the DCE, ACE, and SDCE methods. For DCE and SDCE, the formation of an impermeable oxide layer at the cathode and the occurrence of corrosion at the anode due to oxidation made the COD removal process less efficient compared with SACE processes. From the experimental results it can be concluded that the SACE has the lowest power consumption and higher process efficiency than the other EC methods and can be a promising solution for removing pollutants from domestic wastewater.
Collapse
|
23
|
Organic Pollutants Removal from Olive Mill Wastewater Using Electrocoagulation Process via Central Composite Design (CCD). WATER 2021. [DOI: 10.3390/w13243522] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Electrocoagulation (EC) was studied in this study as a potential alternative approach for treating Olive Mill Wastewater (OMW). Aluminum plates were utilized as anode and cathode to evaluate the removal of Chemical Oxygen Demand (COD) from OMW and the aluminum electrode’s weight loss. Central Composite Experimental Design (CCD) and Response Surface Methodology were used to optimize its performance. Anodes were weighed before and after each electrocoagulation experiment, to compare the experimental and the theoretical dissolved aluminum weights calculated using Faraday’s law. We discovered the following EC conditions for CCD: current density = 15 mA/cm2, pH = 4, and electrolysis time of 30 min. Under these conditions, the maximum COD removal ratio was 41%, equating to an Al weight loss of 288.89 g/m3 at an estimated operating cost of 1.60 USD/m3. According to the response optimizer, the most economical operating settings for COD removal efficiency of 58.888% are pH 4, a current density of 18.41 mA/cm2, electrolysis time of 36.82 min, and Al weight loss of 337.33 g/m3, with a projected running cost of 2.00 USD/m3.
Collapse
|
24
|
Use of Electrocoagulation for Treatment of Pharmaceutical Compounds in Water/Wastewater: A Review Exploring Opportunities and Challenges. WATER 2021. [DOI: 10.3390/w13152105] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Increasing dependency on pharmaceutical compounds including antibiotics, analgesics, antidepressants, and other drugs has threatened the environment as well as human health. Their occurrence, transformation, and fate in the environment are causing significant concerns. Several existing treatment technologies are there with their pros and cons for the treatment of pharmaceutical wastewater (PWW). Still, electrocoagulation is considered as the modern and decisive technology for treatment. In the EC process, utilizing electricity (AC/DC) and electrodes, contaminants become coagulated with the metal hydroxide and are separated by co-precipitation. The main mechanism is charge neutralization and adsorption of contaminants on the generated flocs. The range of parameters affects the EC process and is directly related to the removal efficiency and its overall operational cost. This process only could be scaled up on the industrial level if process parameters become optimized and energy consumption is reduced. Unfortunately, the removal mechanism of particular pharmaceuticals and complex physiochemical phenomena involved in this process are not fully understood. For this reason, further research and reviews are required to fill the knowledge gap. This review discusses the use of EC for removing pharmaceuticals and focuses on removal mechanism and process parameters, the cost assessment, and the challenges involved in mitigation.
Collapse
|