1
|
Ghosh S, Rector JA, Saknite I, Smith HB, Walsh KM, Byram BC, Bellan LM, Tkaczyk ER. mTG-Gelatin phantoms as standardized testbeds for skin biomechanical measurements with Myoton. J Mech Behav Biomed Mater 2024; 158:106651. [PMID: 39059120 DOI: 10.1016/j.jmbbm.2024.106651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 06/24/2024] [Accepted: 07/01/2024] [Indexed: 07/28/2024]
Abstract
Quantitative assessment of skin mechanical properties can play a pivotal role in diagnosing and tracking various dermatological conditions. Myoton is a promising tool that rapidly and noninvasively measures five skin biomechanical parameters. Accurate interpretation of these parameters requires systematic in vitro testing with easy-to-fabricate, cost-effective skin-mimicking phantoms with controllable properties. In this study, we assessed the ability of phantoms made with 5% and 10% gelatin crosslinked with microbial transglutaminase (mTG) to mimic the human skin for Myoton measurements. We discovered that each of the five Myoton parameters displayed moderate to high correlations with shear elastic modulus of the phantoms. Furthermore, Myoton effectively tracked changes in the mechanical properties of these models over time. Additionally, we designed bilayer phantoms incorporating both dermis and subcutaneous tissue-mimicking layers. Myoton successfully distinguished changes in the mechanical properties of the bilayer phantoms due to the introduction of a stiff 2 mm top layer. We also found that 5% mTG-gelatin phantoms mimic Myoton measurements from healthy subjects and 10% phantoms mimic patients with sclerotic chronic graft-versus-host disease (cGVHD). Therefore, multi-layered mTG-gelatin models for skin and soft tissues can serve as standardized testbeds to study different sclerotic skin conditions in a systematic manner.
Collapse
Affiliation(s)
- Shramana Ghosh
- Medicine Service and Research Service, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA; Department of Dermatology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - John A Rector
- Department of Mechanical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA
| | - Inga Saknite
- Department of Dermatology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Hayden B Smith
- Medicine Service and Research Service, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA; Department of Dermatology, Vanderbilt University Medical Center, Nashville, TN, USA; Vanderbilt University School of Medicine, Nashville, TN, USA
| | - Kristy M Walsh
- Department of Biomedical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA
| | - Brett C Byram
- Department of Biomedical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA
| | - Leon M Bellan
- Department of Mechanical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA
| | - Eric R Tkaczyk
- Medicine Service and Research Service, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA; Department of Dermatology, Vanderbilt University Medical Center, Nashville, TN, USA; Vanderbilt University School of Medicine, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University School of Engineering, Nashville, TN, USA.
| |
Collapse
|
2
|
OH SH, Noh E, Min B. Applicability of non-invasive, digital palpation device to detection of woody breast conditions in chicken breast muscle. JOURNAL OF ANIMAL SCIENCE AND TECHNOLOGY 2024; 66:1069-1078. [PMID: 39398306 PMCID: PMC11466729 DOI: 10.5187/jast.2024.e14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/22/2024] [Accepted: 01/30/2024] [Indexed: 10/15/2024]
Abstract
Woody breast (WB) is one of muscle myopathy found in chicken breast, characterized with enlarged size and extremely stiff texture. The WB condition is one of the most prevalent quality issues in the modern poultry industry. WB has been shown to be heritable, but no effective detection method of WB severity in live birds exists for the selection purpose. The objective of this study was to determine potential of a non-invasive, portable digital palpation device as WB detection method that can be used for the selection to estimate the heritability of WB. The physical and functional properties of WB was also investigated in comparison with normal breast (NB). Two hundred ten breast muscles were obtained from a local processing plant one day after harvest and sorted based on WB scoring (1 for NB and 2 and 3 for WB). The samples were subjected to physical and physicochemical analyses, determining biomechanical properties (muscle tone, stiffness, elasticity, relaxation, and creep), pH, color, cooking yield, and texture (firmness and compression energy were used for raw meat and shear force and energy for cooked meat). The least squares means of the following variables were significantly different between WB and NB (p < 0.01): stiffness (603.4 vs 565.8; N/m), and elasticity (1.40 vs 1.55). However, relaxation and creep were not significantly different (p > 0.05). These results collectively showed that biomechanical properties of WB differ from NB. The degree of muscle stiffness in WB can be considered as a trait to be selected. The WB score showed strong negative correlations with cooking yield (-0.77) and cooked L*(-0.74), which means that as the breast becomes harder, the cooking yield decreases, and the color becomes darker after cooking. The WB score showed high correlations with physical and functional characteristics and exhibited strong correlations with the biomechanical properties measured by the device. Therefore, the results indicated that the digital palpation device has potential to detect the WB severity (degree of stiffness) of breast muscle.
Collapse
Affiliation(s)
- Sang-Hyon OH
- Division of Animal Science, Gyeongsang
National University, Jinju 52725, Korea
| | - Euyeon Noh
- Department of Agriculture, Food, and
Resource Sciences, University of Maryland Eastern Shore,
Princess Ann 21853, USA
| | - Byungrok Min
- Department of Agriculture, Food, and
Resource Sciences, University of Maryland Eastern Shore,
Princess Ann 21853, USA
| |
Collapse
|
3
|
Fan T, Chen R, Wei M, Zhou X, Zheng P, Zhou J, He P, Zhan X, Xie J, Li R, Li R, Cao P, Huang G. Effects of radial extracorporeal shock wave therapy on flexor spasticity of the upper limb in post-stroke patients: A randomized controlled trial. Clin Rehabil 2024; 38:1200-1213. [PMID: 38863234 DOI: 10.1177/02692155241258740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2024]
Abstract
OBJECTIVE This study aimed to assess the efficacy of radial extracorporeal shock wave therapy in treating upper limb spasticity after a stroke. DESIGN Randomized controlled trial. SETTING Zhujiang Hospital of Southern Medical University. SUBJECTS This study included 95 people with stroke. INTERVENTION The active (n = 47) and sham-placebo (n = 48) radial extracorporeal shockwave therapy groups received three treatment sessions (every third day). MAIN MEASURES The Modified Ashworth Scale, Hmax/Mmax ratio, root mean square, co-contraction ratio, mechanical parameters of the muscle and temperature were measured at baseline and days 2, 5 and 8. RESULTS Among the 135 potential participants screened, 100 were enrolled and allocated randomly, with 95 participants ultimately being included in the intent-to-treat analysis dataset. The active group showed significantly better improvements in upper limb spasticity and muscle function than did the sham-placebo group. Greater improvements in the Modified Ashworth Scale were observed in the active group than in the sham-placebo group (difference, -0.45; 95% CI, -0.69 to -0.22; P < 0.001). Moreover, significant differences in root mean square, co-contraction ratio and Hmax/Mmax ratio were observed between the two groups (all P < 0.001). The mechanical parameters of the biceps muscle were significantly better in the active group than in the sham-placebo group (P < 0.001). The active group had a higher temperature than the sham-placebo group, although the difference was not significant (P = 0.070). CONCLUSIONS This study revealed that the treatment with extracorporeal shockwave therapy can relieve upper limb spasticity in people with stroke.
Collapse
Affiliation(s)
- Tao Fan
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- School of Rehabilitation Medicine, Southern Medical University, Guangzhou, Guangdong, China
| | - Rong Chen
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Mingyang Wei
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Xiangying Zhou
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Peng Zheng
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Jing Zhou
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Peichen He
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Xiaojia Zhan
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Jingyu Xie
- Clinical Research Center, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- Department of Biostatistics, School of Public Health, Southern Medical University, Guangzhou, Guangdong, China
| | - Rongdong Li
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Rihui Li
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Peihua Cao
- Clinical Research Center, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- Department of Biostatistics, School of Public Health, Southern Medical University, Guangzhou, Guangdong, China
| | - Guozhi Huang
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
- School of Rehabilitation Medicine, Southern Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
4
|
Moon H, Lee S, Yoon DE, Lee IS, Chae Y. Exploratory Study of Biomechanical Properties and Pain Sensitivity at Back-Shu Points. Brain Sci 2024; 14:823. [PMID: 39199515 PMCID: PMC11353071 DOI: 10.3390/brainsci14080823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/25/2024] [Accepted: 08/13/2024] [Indexed: 09/01/2024] Open
Abstract
OBJECTIVES Hypersensitive acupoints in specific body areas are associated with corresponding internal or visceral disorders. Back-shu points are clinically significant for the diagnosis of visceral organ disease, according to the biomechanical characteristics of the acupoints. In this study, we assessed the biomechanical characteristics and pain sensitivities of five back-shu points linked to five visceral organs in healthy participants. METHODS The study included 48 volunteer participants. A myotonometry was used to assess muscle tone and muscle stiffness at five back-shu points associated with visceral organs. Pressure was monitored using a microcontroller and a force sensor. Pain sensitivity was assessed in response to deep pressure pain produced by a constant force. RESULTS Substantial differences in muscle tone and stiffness were observed at the five back-shu points; muscle tone was highest at BL15, whereas muscle tone and muscle stiffness were lowest at BL23. Moreover, pain sensitivity was significantly different among the acupoints; pain sensitivity was highest at BL23. There was a significant negative correlation between muscle tone and pain sensitivity. CONCLUSIONS We found significant differences in muscle tone, muscle stiffness, and pain sensitivity among five back-shu points associated with visceral organs, which may be attributable to anatomical variations at each point. Our findings suggest that differences at back-shu points should be considered to ensure the accurate diagnosis of visceral disease.
Collapse
Affiliation(s)
- Heeyoung Moon
- Department of Science in Korean Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea; (H.M.); (D.-E.Y.); (I.-S.L.)
| | - Seoyoung Lee
- Department of Behavioral Medicine, Faculty of Medicine, Institute of Basic Medical Sciences, University of Oslo, 0372 Oslo, Norway;
| | - Da-Eun Yoon
- Department of Science in Korean Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea; (H.M.); (D.-E.Y.); (I.-S.L.)
| | - In-Seon Lee
- Department of Science in Korean Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea; (H.M.); (D.-E.Y.); (I.-S.L.)
| | - Younbyoung Chae
- Department of Science in Korean Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea; (H.M.); (D.-E.Y.); (I.-S.L.)
| |
Collapse
|
5
|
Ferran de la Cierva S, Terrasa D, Garaycochea O, Del Rio B, Urdin M, Fernandez S. MyotonPRO as a new valid tool for measuring cervical muscle tension. A reliability study. LOGOP PHONIATR VOCO 2024:1-8. [PMID: 39120117 DOI: 10.1080/14015439.2024.2388896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 07/17/2024] [Accepted: 07/31/2024] [Indexed: 08/10/2024]
Abstract
OBJECTIVE The main objective of this study is to test the reliability of a non-invasive objective method for the measurement of biomechanical parameters of cervicofacial muscle groups, with the purpose of diagnosis and evaluation of voice disorders' treatments, especially focused on muscle tension dysphonia. STUDY DESIGN Prospective study. METHODS The device used is a handheld myotonometer (MyotonPRO) that measures biomechanical and viscoelastic properties in superficial soft tissues frequency, stiffness, elasticity, relaxation time and creep. It is used in the field of medicine, sport and research. This pilot study includes 10 subjects, who have been measured in the masseter, sternocleidomastoid, orbicularis oris, semispinalis capitis, suprahyoid, infrahyoid and trapezius muscles on each side. Measurements were performed by 2 evaluators to assess inter-evaluator reliability. Subsequently, one of them repeated the measurements to assess intra-evaluator reliability. RESULTS The results revealed good to excellent inter-rater reliability for the masseter, sternocleidomastoid, trapezius and suprahyoid muscles, with lower ICCs for the stiffness and creep properties. Intra-rater reliability was good to excellent for the masseter, sternocleidomastoid, semispinalis capitis and suprahyoid muscles. The lowest ICCs were found in the stiffness and creep properties. CONCLUSION The use of a myotonometer to measure the mechanical properties of selected cervical and orofacial muscles is a reliable and reproducible method. Future research is needed to establish an association between the properties of these muscles and their role in voice disorders, as well as to determine whether this tool can aid diagnosis with quantifiable and objectifiable indicators, and for monitoring and treatment efficacy.
Collapse
Affiliation(s)
| | - David Terrasa
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Octavio Garaycochea
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Beatriz Del Rio
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Mikel Urdin
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| | - Secundino Fernandez
- Otorhinolaryngology Department, Clínica Universidad de Navarra. Pamplona, Spain
| |
Collapse
|
6
|
Fukushige K, Okubo T, Shan X, Takeuchi T, Misaki N, Naito M. Regional variations and sex-related differences of stiffness in human tracheal ligaments. Surg Radiol Anat 2024; 46:877-883. [PMID: 38683421 DOI: 10.1007/s00276-024-03361-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 03/31/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE There have been numerous studies focused on the stiffness of tracheal cartilage. However, no research has been conducted specifically on the annular ligament, nor have any regional differences in the annular ligament been identified. The purpose of this study was to investigate the stiffness of the ligaments present between the thyroid, cricoid and tracheal cartilages. METHODS The ligaments were identified in the cervical region of living subjects with ultrasonography. The stiffness of the ligaments was measured from the body surface using a digital palpation device (MyotonPRO). Since it is impossible to measure the entire trachea in a living subject, an additional measurement was performed on human cadavers. RESULTS Both in vivo and cadaveric investigations found that the stiffness of annular ligaments decreased gradually from the superior to inferior parts. There was no difference in the stiffness between males and females in the superior part of the trachea. However, the stiffness of the middle and inferior parts was predominantly higher in females than in males. Furthermore, males showed significant differences in stiffness between the superior and middle parts, while females showed no significant differences. CONCLUSION These results reveal that there are regional and sex-related differences in the stiffness of human tracheal ligaments.
Collapse
Affiliation(s)
- Kaori Fukushige
- Department of Anatomy, School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
| | - Tomohito Okubo
- Department of Anatomy, School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
- Department of General Thoracic, Breast and Endocrinological Surgery, Kagawa University Hospital, 1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, 761-0793, Japan
| | - Xiyao Shan
- Department of Anatomy, School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Takao Takeuchi
- Department of Anatomy, School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| | - Noriyuki Misaki
- Department of General Thoracic, Breast and Endocrinological Surgery, Kagawa University Hospital, 1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa, 761-0793, Japan
| | - Munekazu Naito
- Department of Anatomy, School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan
| |
Collapse
|
7
|
Römer C, Czupajllo J, Wolfarth B, Sichting F, Legerlotz K. The Myometric Assessment of Achilles Tendon and Soleus Muscle Stiffness before and after a Standardized Exercise Test in Elite Female Volleyball and Handball Athletes-A Quasi-Experimental Study. J Clin Med 2024; 13:3243. [PMID: 38892954 PMCID: PMC11172482 DOI: 10.3390/jcm13113243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/23/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024] Open
Abstract
Background: The high prevalence of injuries in female athletes necessitates a course of action that not only enhances research in this field but also incorporates improved prevention programs and regular health monitoring of highly stressed structures such as tendons and muscles. Since myometry is already used by coaches and physiotherapists, it is important to investigate whether tissue stiffness varies in different types of sports, and whether such measures are affected by an acute training session. Methods: Myometric measurements of the Achilles tendon (AT) and soleus muscle (SM) were performed in the longitudinal plane and relaxed tendon position. In total, 38 healthy professional female athletes were examined, applying a quasi-experimental study design, with subgroup analysis performed for different sports. To investigate the stiffness of the AT and SM, 24 female handball and volleyball athletes performed a standardized maximal incremental performance test on a treadmill. In this subgroup, myometric measurements were taken before and after the exercise test. Results: The measurements showed no significant difference between the mean pre- (AT: 661.46 N/m; SM 441.48 N/m) and post-exercise stiffness (AT: 644.71 N/m; SM: 439.07 N/m). Subgroup analysis for different types of sports showed significantly lower AT and SM stiffness in swimming athletes compared to handball (p = 0.002), volleyball (p = 0.000) and hammer throw athletes (p = 0.008). Conclusions: Myometry can be performed on the same day as an acute training session in healthy female professional volleyball and handball athletes. Female swimmers have significantly lower AT and SM stiffness compared to female handball, volleyball and hammer throw athletes. These results show that the stiffness differences in the AT and SM can be assessed by myometry.
Collapse
Affiliation(s)
- Claudia Römer
- Department of Sports Medicine, Charité University Medicine Berlin, 10115 Berlin, Germany
| | - Julia Czupajllo
- Department of Sports Medicine, Charité University Medicine Berlin, 10115 Berlin, Germany
| | - Bernd Wolfarth
- Department of Sports Medicine, Charité University Medicine Berlin, 10115 Berlin, Germany
| | - Freddy Sichting
- Department of Human Movement Science, Chemnitz University of Technology, 09111 Chemnitz, Germany
| | - Kirsten Legerlotz
- Movement Biomechanics, Institute of Sport Sciences, Humboldt University Berlin, 10115 Berlin, Germany
| |
Collapse
|
8
|
Saito R, Shagawa M, Sugimoto Y, Hirai T, Kato K, Sekine C, Yokota H, Hirabayashi R, Ishigaki T, Akuzawa H, Togashi R, Yamada Y, Osanami H, Edama M. Changes in the mechanical properties of the thigh and lower leg muscle-tendon units during the early follicular and early luteal phases. Front Sports Act Living 2024; 6:1323598. [PMID: 38596640 PMCID: PMC11002163 DOI: 10.3389/fspor.2024.1323598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 03/12/2024] [Indexed: 04/11/2024] Open
Abstract
Background This study aimed to determine changes in the muscle and tendon stiffness of the thigh and lower leg muscle-tendon units during the early follicular and early luteal phases, and check for possible relations between muscle and tendon stiffness in each phase. Methods The sample consisted of 15 female university students with regular menstrual cycles. The basal body temperature method, ovulation kit, and salivary estradiol concentration measurement were used to estimate the early follicular and early luteal phases. A portable digital palpation device measured muscle-tendon stiffness in the early follicular and early luteal phases. The measurement sites were the rectus femoris (RF), vastus medialis (VM), patellar tendon (PT), medial head of gastrocnemius muscle, soleus muscle, and Achilles tendon. Results No statistically significant differences in the thigh and lower leg muscle-tendon unit stiffness were seen between the early follicular and early luteal phases. Significant positive correlations were found between the stiffness of the RF and PT (r = 0.608, p = 0.016) and between the VM and PT (r = 0.737, p = 0.002) during the early luteal phase. Conclusion The present results suggest that the stiffness of leg muscle-tendon units of the anterior thigh and posterior lower leg do not change between the early follicular and early luteal phases and that tendons may be stiffer in those women who have stiffer anterior thigh muscles during the early luteal phase.
Collapse
|
9
|
Schoenrock B, Muckelt PE, Hastermann M, Albracht K, MacGregor R, Martin D, Gunga HC, Salanova M, Stokes MJ, Warner MB, Blottner D. Muscle stiffness indicating mission crew health in space. Sci Rep 2024; 14:4196. [PMID: 38378866 PMCID: PMC10879143 DOI: 10.1038/s41598-024-54759-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 02/16/2024] [Indexed: 02/22/2024] Open
Abstract
Muscle function is compromised by gravitational unloading in space affecting overall musculoskeletal health. Astronauts perform daily exercise programmes to mitigate these effects but knowing which muscles to target would optimise effectiveness. Accurate inflight assessment to inform exercise programmes is critical due to lack of technologies suitable for spaceflight. Changes in mechanical properties indicate muscle health status and can be measured rapidly and non-invasively using novel technology. A hand-held MyotonPRO device enabled monitoring of muscle health for the first time in spaceflight (> 180 days). Greater/maintained stiffness indicated countermeasures were effective. Tissue stiffness was preserved in the majority of muscles (neck, shoulder, back, thigh) but Tibialis Anterior (foot lever muscle) stiffness decreased inflight vs. preflight (p < 0.0001; mean difference 149 N/m) in all 12 crewmembers. The calf muscles showed opposing effects, Gastrocnemius increasing in stiffness Soleus decreasing. Selective stiffness decrements indicate lack of preservation despite daily inflight countermeasures. This calls for more targeted exercises for lower leg muscles with vital roles as ankle joint stabilizers and in gait. Muscle stiffness is a digital biomarker for risk monitoring during future planetary explorations (Moon, Mars), for healthcare management in challenging environments or clinical disorders in people on Earth, to enable effective tailored exercise programmes.
Collapse
Affiliation(s)
- Britt Schoenrock
- NeuroMuscular System & Signaling Group, Berlin Center of Space Medicine and Extreme Environments, 10115 Berlin, Germany, Institute of Integrative Neuroanatomy, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10115 Berlin, Germany, 10115, Berlin, Germany
| | - Paul E Muckelt
- School of Health Sciences, University of Southampton, Southampton, UK
| | - Maria Hastermann
- Experimental and Clinical Research Center (ECRC) and NeuroCure Clinical Research Center (NCRC), Charité - Universitätsmedizin Berlin, Berlin, Germany
| | | | | | | | - Hans-Christian Gunga
- Institute of Physiology, Berlin Center of Space Medicine and Extreme Environments, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10115 Berlin, Germany, Berlin, Germany
| | - Michele Salanova
- NeuroMuscular System & Signaling Group, Berlin Center of Space Medicine and Extreme Environments, 10115 Berlin, Germany, Institute of Integrative Neuroanatomy, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10115 Berlin, Germany, 10115, Berlin, Germany
| | - Maria J Stokes
- School of Health Sciences, University of Southampton, Southampton, UK
| | - Martin B Warner
- School of Health Sciences, University of Southampton, Southampton, UK
| | - Dieter Blottner
- NeuroMuscular System & Signaling Group, Berlin Center of Space Medicine and Extreme Environments, 10115 Berlin, Germany, Institute of Integrative Neuroanatomy, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10115 Berlin, Germany, 10115, Berlin, Germany.
| |
Collapse
|
10
|
Chang CH, Ho CS, Li F, Chen CY, Yeh HC, Ho CA. Acute effects of muscle mechanical properties after 2000-m rowing in young male rowers. PeerJ 2024; 12:e16737. [PMID: 38188161 PMCID: PMC10771759 DOI: 10.7717/peerj.16737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 12/07/2023] [Indexed: 01/09/2024] Open
Abstract
Background The mechanical properties of muscles, such as changes in muscle tone and stiffness, are related to sports performance and injuries. Rowers are at increased risk of muscle fatigue and injury during high-repetition and heavy-load cyclic muscle actions. In view of this, the aim of the present study was to investigate the acute effect on muscle tone and stiffness, as well as bilateral muscle asymmetry, in high school rowers after a 2000-meter rowing ergometer test. Methods Twelve young male rowers (age = 17.1 ± 0.9 years, body weight = 73.5 ± 9.7 kg) were included in the study. The data of muscle tone (frequency) and stiffness of the posterior deltoids (PD), latissimus dorsi (LD), and rectus femoris (RF) (dominant and non-dominant side) before and after a 2000-m rowing ergometer test were collected using a handheld MyotonPRO device. Results After the rowing ergometer test, the muscle tone of dominant side PD, LD, and RF were significantly increased (p < 0.05). On the other hand, the muscle stiffness of the non-dominant side LD and RF, as well as the dominant side PD, LD, and RF were significantly increased after the rowing ergometer test (p < 0.05). The muscle tone and stiffness results showed that the dominant side PD, LD, and RF were all significantly higher than the non-dominant side after the rowing ergometer test (p < 0.05), where bilateral PD and RF exhibits moderate asymmetry (5% < symmetry index < 10%). Conclusions After a high-intensity and high-load 2000-m rowing ergometer test, PD, LD, and RF showed increases in muscle tone and stiffness, as well as changes in the symmetry of bilateral muscle mechanical properties.
Collapse
Affiliation(s)
- Chun-Hao Chang
- Graduate Institute of Sports Science, National Taiwan Sport University, Taoyuan City, Taiwan
| | - Chin-Shan Ho
- Graduate Institute of Sports Science, National Taiwan Sport University, Taoyuan City, Taiwan
| | - Fang Li
- School of Physical Education, Central China Normal University, Wuhan City, Hubei Province, China
| | - Chao-Yuan Chen
- Graduate Institute of Sports Science, National Taiwan Sport University, Taoyuan City, Taiwan
- Sport Office, National Taipei University of Business, Taipei City, Taiwan
| | - Hung-Chih Yeh
- Graduate Institute of Sports Science, National Taiwan Sport University, Taoyuan City, Taiwan
| | - Chia-An Ho
- Graduate Institute of Sports Science, National Taiwan Sport University, Taoyuan City, Taiwan
| |
Collapse
|
11
|
Dakkumadugula A, Pankaj L, Alqahtani AS, Ullah R, Ercisli S, Murugan R. Space nutrition and the biochemical changes caused in Astronauts Health due to space flight: A review. Food Chem X 2023; 20:100875. [PMID: 38144801 PMCID: PMC10740090 DOI: 10.1016/j.fochx.2023.100875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 09/05/2023] [Accepted: 09/11/2023] [Indexed: 12/26/2023] Open
Abstract
Astronauts required food that is healthy, nutritious, and tasted good, while also meeting their dietary needs. To ensure the astronauts' nutritional needs are met, a Nutritional Status Assessment Supplemental Medical Objective (Nutrition SMO) is conducted. This involves collecting blood and urine samples from the astronauts, which are then tested and analysed. The assessment looks for indications of bone health, muscle loss, hormonal imbalances, gastrointestinal functions, cardiovascular health, iron metabolism, ophthalmic changes, and immune changes that occur during space flight under conditions of microgravity or weightlessness. It was discovered that iron levels in astronauts tend to increase due to the decrease in body volume during space flight. It requires skilful optimization considering nutrient delivery, shelf life, and packaging of space food, while minimizing resource usage and ensuring reliability, safety, and addressing the physiological and psychological effects on the crew members.
Collapse
Affiliation(s)
- Angel Dakkumadugula
- Food Science and Technology, Department of Food Technology, Faculty of Life and Allied Health Sciences, Ramaiah University of Applied Sciences, Bangalore 560054, Karnataka, India
| | - Lakshaa Pankaj
- Food Science and Technology, Department of Food Technology, Faculty of Life and Allied Health Sciences, Ramaiah University of Applied Sciences, Bangalore 560054, Karnataka, India
| | - Ali S. Alqahtani
- Medicinal Aromatic and Poisonous Plants Research Center, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia
| | - Riaz Ullah
- Medicinal Aromatic and Poisonous Plants Research Center, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia
| | - Sezai Ercisli
- Department of Horticulture, Faculty of Agriculture, Ataturk University, 25240 Erzurum, Turkey
- HGF Agro, Ata Teknokent, TR-25240, Erzurum, Turkiye
| | - Rajadurai Murugan
- Department of Food Technology, Faculty of Life and Allied Health Sciences, Ramaiah University of Applied Sciences, Bangalore 560054, Karnataka, India
| |
Collapse
|
12
|
Ghosh S, Baker L, Chen F, Khera Z, Vain A, Zhang K, Hood A, Smith H, Chen H, Jagasia M, Tkaczyk E. Interrater reproducibility of the Myoton and durometer devices to quantify sclerotic chronic graft-versus-host disease. Arch Dermatol Res 2023; 315:2545-2554. [PMID: 37227518 DOI: 10.1007/s00403-023-02626-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 03/30/2023] [Accepted: 04/10/2023] [Indexed: 05/26/2023]
Abstract
Chronic graft-versus-host disease (cGVHD) is a severe complication in long-term survivors of allogeneic hematopoietic stem cell transplantation. This disease is challenging to manage clinically due to a lack of validated tools to quantitatively measure skin sclerosis. The current gold standard for measuring skin sclerosis is the NIH Skin Score which has only moderate agreement among clinicians and experts. To more accurately assess skin sclerosis in cGVHD, the Myoton and durometer devices can be used to directly measure biomechanical parameters of the skin. However, the reproducibility of these devices is not known in patients with cGVHD. To determine this reproducibility, three observers independently measured 10 anatomic sites in each of seven patients with sclerotic cGVHD using the Myoton and durometer. Clinical reproducibility was measured by mean pairwise differences (U-statistic) and intraclass correlation coefficients (ICCs) with 95% confidence intervals (CIs). Mean pairwise differences, expressed in true physical units, were used to report typical errors for each anatomic site and device. Mean pairwise differences were less than 11% of the average overall values for all five Myoton parameters and durometer hardness. These were lower for Myoton creep (4.1%), relaxation time (4.7%), and frequency (5.1%) than decrement (9.0%), stiffness (10.4%), and durometer hardness (9.0%). Myoton parameters creep, relaxation time, and frequency showed promise for capturing skin biomechanics more accurately than Myoton stiffness, decrement, or durometer hardness. Mean pairwise differences trended highest in the shin and volar forearm and lowest in the dorsal forearm. The interobserver ICC for overall (averaged across all measured body sites of a patient) creep (0.94; 95% CI 0.87-1.00), relaxation time (0.96; 95% CI 0.90-1.00), and frequency (0.95; 95% CI 0.88-1.00), trended higher than that for decrement (0.43; 95% CI 0.00-0.88), stiffness (0.92; 95% CI 0.81-1.00), and durometer hardness (0.82; 95% CI 0.61-1.00). Similar trends were observed in healthy participants. These findings can help clinicians design better studies to assess therapeutic response to new cGVHD treatments and support the interpretation of future measurements.
Collapse
Affiliation(s)
- Shramana Ghosh
- Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Laura Baker
- Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Fuyao Chen
- Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
- Medical Scientist Training Program, Yale School of Medicine, New Haven, CT, USA
| | - Zain Khera
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Arved Vain
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
- University of Tartu Institute of Physics, Tartu, Estonia
| | - Kathy Zhang
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Alexis Hood
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Hayden Smith
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA
| | - Heidi Chen
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt-Ingram Cancer Center, Nashville, TN, USA
| | | | - Eric Tkaczyk
- Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA.
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
- Vanderbilt-Ingram Cancer Center, Nashville, TN, USA.
| |
Collapse
|
13
|
Kurashina W, Takahashi T, Sasanuma H, Saitsu A, Takeshita K. Relationship Between Achilles Tendon Stiffness Using Myoton PRO and Translation Using a Tensile Testing Machine: A Biomechanical Study of a Porcine Model. Cureus 2023; 15:e49359. [PMID: 38146575 PMCID: PMC10749689 DOI: 10.7759/cureus.49359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2023] [Indexed: 12/27/2023] Open
Abstract
Background Achilles tendinopathy is a common ankle disorder in both the general population and athletes. This condition can alter the mechanical characteristics of the Achilles tendon (AT) by decreasing tendon stiffness. Achilles tendinopathy is primarily treated conservatively; however, few monitoring tools exist for evaluating the condition of the AT. The Myoton PRO (Myoton AS, Tallinn, Estonia) device is a handheld tool used to evaluate tissue stiffness. However, no basic studies have examined the validity of Myoton PRO for assessing the AT. This study aimed to assess the validity of Myoton PRO using animal ATs and to examine its clinical applicability. Methods We used 28 fresh porcine ankles and evaluated AT stiffness at the calcaneus insertion site (AT0) and 2.0 cm above the calcaneus (AT2) using Myoton PRO. We also measured changes in the AT length using a tensile testing machine during the cyclic loading test. We investigated the correlation between dynamic stiffness and length change. Furthermore, we assessed the difference in stiffness between AT0 and AT2. Results The dynamic stiffness was 717.6 ± 183.1 N/m at AT0 and 467.4 ± 152.3 N/m at AT2. The change in length during the cyclic loading test was 1.8 ± 0.7 mm. The correlation between dynamic stiffness and length change was as follows: AT0, r=-0.61; AT2, r=-0.64 (P<0.001). The dynamic stiffness at AT0 was significantly greater than that at AT2 (P<0.001). Conclusions AT assessment using Myoton PRO has potential clinical utility as an indicator of tissue stiffness.
Collapse
Affiliation(s)
- Wataru Kurashina
- Graduate School of Medicine, Jichi Medical University, Shimotsuke, JPN
- Department of Rehabilitation, Tochigi Medical Center Shimotsuga, Tochigi, JPN
| | - Tsuneari Takahashi
- Department of Orthopaedic Surgery, Ishibashi General Hospital, Shimotsuke, JPN
| | - Hideyuki Sasanuma
- Department of Orthopaedics, Jichi Medical University, Shimotsuke, JPN
| | - Akihiro Saitsu
- Department of Orthopaedics, Jichi Medical University, Shimotsuke, JPN
| | | |
Collapse
|
14
|
Campi G, Ricci A, Costa N, Genovesi F, Branca JJV, Paternostro F, Della Posta D. Dynamic Correlations and Disorder in the Masticatory Musculature Network. Life (Basel) 2023; 13:2107. [PMID: 38004247 PMCID: PMC10672239 DOI: 10.3390/life13112107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 10/17/2023] [Accepted: 10/21/2023] [Indexed: 11/26/2023] Open
Abstract
BACKGROUND Temporomandibular joint (TMJ) disorders, which affect millions of people worldwide, have multiple etiological factors that make an accurate diagnosis and effective treatments difficult. As a consequence, the gold standard diagnostic criteria for TMJ disorders remain elusive and often depend on subjective decisions. AIM In this context, the lack of a non-invasive quantitative methodology capable of assessing the functional physiological state and, consequently, identifying risk indicators for the early diagnosis of TMJ disorders must be tackled and resolved. METHODOLOGY In this work, we have studied the biomechanics and viscoelastic properties of the functional masticatory system by a non-invasive approach involving 52 healthy subjects, analysed by statistical-physics analysis applied to myotonic measurements on specific points of the masticatory system designing a TMJ network composed of 17 nodes and 20 links. RESULTS We find that the muscle tone and viscoelasticity of a specific cycle linking frontal, temporal, and mandibular nodes of the network play a prominent role in the physiological functionality of the system. At the same time, the functional state is characterised by a landscape of nearly degenerated levels of elasticity in all links of the network, making this parameter critically distributed and deviating from normal behaviour. CONCLUSIONS Time evolution and dynamic correlations between biomechanics and viscoelastic parameters measured on the different cycles of the network provide a quantitative framework associated with the functional state of the masticatory system. Our results are expected to contribute to enriching the taxonomy of this system, primarily based on clinical observations, patient symptoms, and expert consensus.
Collapse
Affiliation(s)
- Gaetano Campi
- Institute of Crystallography, CNR, Via Salaria Km 29.300, 00015 Monterotondo, Italy;
| | - Alessandro Ricci
- Duferco Corporate Innovation, Via Trevano 2A, 6900 Lugano, Switzerland;
| | - Nicola Costa
- The Anatomical Network APS, Via Fermo 2c, 00182 Rome, Italy; (N.C.); (D.D.P.)
| | | | - Jacopo Junio Valerio Branca
- Department of Experimental and Clinical Medicine, Anatomy and Histology Section, University of Florence, 50134 Florence, Italy;
| | - Ferdinando Paternostro
- Department of Experimental and Clinical Medicine, Anatomy and Histology Section, University of Florence, 50134 Florence, Italy;
| | - Daniele Della Posta
- The Anatomical Network APS, Via Fermo 2c, 00182 Rome, Italy; (N.C.); (D.D.P.)
| |
Collapse
|
15
|
Kopecká B, Ravnik D, Jelen K, Bittner V. Objective Methods of Muscle Tone Diagnosis and Their Application-A Critical Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:7189. [PMID: 37631726 PMCID: PMC10458714 DOI: 10.3390/s23167189] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 08/09/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023]
Abstract
"Muscle tone" is a clinically important and widely used term and palpation is a crucial skill for its diagnosis. However, the term is defined rather vaguely, and palpation is not measurable objectively. Therefore, several methods have been developed to measure muscle tone objectively, in terms of biomechanical properties of the muscle. This article aims to summarize these approaches. Through database searches, we identified those studies related to objective muscle tone measurement in vivo, in situ. Based on them, we described existing methods and devices and compared their reliability. Furthermore, we presented an extensive list of the use of these methods in different fields of research. Although it is believed by some authors that palpation cannot be replaced by a mechanical device, several methods have already proved their utility in muscle biomechanical property diagnosis. There appear to be two issues preventing wider usage of these objective methods in clinical practice. Firstly, a high variability of their reliability, and secondly, a lack of valid mathematical models that would provide the observed mechanical characteristics with a clear physical significance and allow the results to be compared with each other.
Collapse
Affiliation(s)
- Barbora Kopecká
- Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
| | - David Ravnik
- Faculty of Health Sciences, University of Primorska, 6310 Izola, Slovenia
| | - Karel Jelen
- Faculty of Physical Education and Sport, Charles University, 162 52 Prague, Czech Republic
| | - Václav Bittner
- Faculty of Science, Humanities and Education, Technical University of Liberec, 461 17 Liberec, Czech Republic
| |
Collapse
|
16
|
Swanenburg J, Easthope CA, Meinke A, Langenfeld A, Green DA, Schweinhardt P. Lunar and mars gravity induce similar changes in spinal motor control as microgravity. Front Physiol 2023; 14:1196929. [PMID: 37565140 PMCID: PMC10411353 DOI: 10.3389/fphys.2023.1196929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 07/13/2023] [Indexed: 08/12/2023] Open
Abstract
Introduction: Once more, plans are underway to send humans to the Moon or possibly even to Mars. It is therefore, important to know potential physiological effects of a prolonged stay in space and to minimize possible health risks to astronauts. It has been shown that spinal motor control strategies change during microgravity induced by parabolic flight. The way in which spinal motor control strategies change during partial microgravity, such as that encountered on the Moon and on Mars, is not known. Methods: Spinal motor control measurements were performed during Earth, lunar, Mars, and micro-gravity conditions and two hypergravity conditions of a parabola. Three proxy measures of spinal motor control were recorded: spinal stiffness of lumbar L3 vertebra using the impulse response, muscle activity of lumbar flexors and extensors using surface electromyography, and lumbar curvature using two curvature distance sensors placed at the upper and lower lumbar spine. The participants were six females and six males, with a mean age of 33 years (standard deviation: 7 years). Results: Gravity condition had a statistically significant (Friedmann tests) effect spinal stiffness (p < 0.001); on EMG measures (multifidus (p = 0.047), transversus abdominis (p < 0.001), and psoas (p < 0.001) muscles) and on upper lumbar curvature sensor (p < 0.001). No effect was found on the erector spinae muscle (p = 0.063) or lower curvature sensor (p = 0.170). Post hoc tests revealed a significant increase in stiffness under micro-, lunar-, and Martian gravity conditions (all p's < 0.034). Spinal stiffness decreased under both hypergravity conditions (all p's ≤ 0.012) and decreased during the second hypergravity compared to the first hypergravity condition (p = 0.012). Discussion: Micro-, lunar-, and Martian gravity conditions resulted in similar increases in spinal stiffness, a decrease in transversus abdominis muscle activity, with no change in psoas muscle activity and thus modulation of spinal motor stabilization strategy compared to those observed under Earth's gravity. These findings suggest that the spine is highly sensitive to gravity transitions but that Lunar and Martian gravity are below that required for normal modulation of spinal motor stabilization strategy and thus may be associated with LBP and/or IVD risk without the definition of countermeasures.
Collapse
Affiliation(s)
- Jaap Swanenburg
- Department of Chiropractic Medicine, Integrative Spinal Research ISR, Balgrist University Hospital, Zürich, Switzerland
- Faculty of Medicine, Institute of Anatomy, University of Zurich, Zurich, Switzerland
- Innovation Cluster Space and Aviation (UZH Space Hub), Air Force Center, University of Zurich, Dübendorf, Switzerland
| | - Christopher A. Easthope
- Cereneo—Center for Interdisciplinary Research, Vitznau, Switzerland
- Lake Lucerne Institute, Vitznau, Switzerland
| | - Anita Meinke
- Department of Chiropractic Medicine, Integrative Spinal Research ISR, Balgrist University Hospital, Zürich, Switzerland
| | - Anke Langenfeld
- Department of Chiropractic Medicine, Integrative Spinal Research ISR, Balgrist University Hospital, Zürich, Switzerland
| | - David A. Green
- Centre of Human and Applied Physiological Sciences, King’s College London, London, United Kingdom
- Space Medicine Team, European Astronaut Centre, European Space Agency, Cologne, Germany
- KBRwyle GmbH, Cologne, Germany
| | - Petra Schweinhardt
- Department of Chiropractic Medicine, Integrative Spinal Research ISR, Balgrist University Hospital, Zürich, Switzerland
| |
Collapse
|
17
|
Lee S, Moon H, Ryu Y, Lee IS, Chae Y. Sensory and emotional responses to deep pressure stimulation at myofascial trigger points: a pilot study. Front Neurosci 2023; 17:1197302. [PMID: 37483352 PMCID: PMC10360180 DOI: 10.3389/fnins.2023.1197302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 06/20/2023] [Indexed: 07/25/2023] Open
Abstract
Objective Although manual pressure, such as that used during a massage, is often associated with pain, it can simultaneously be perceived as pleasant when applied to certain body areas. We hypothesized that stimulation of myofascial trigger points (TPs) leads to simultaneous pain and pleasure. TPs are hyperirritable points located in the taut band of the skeletal muscle. Method In this study, we measured the muscle tone, muscle stiffness, and pressure pain threshold of TPs and control points in the left brachioradialis muscle of 48 healthy participants. We also applied deep compression to the two points and collected subjective data on pain, pleasantness, unpleasantness, and relief. Result Greater muscle stiffness was observed in the TPs versus control points (t = 6.55, p < 0.001), and the pain threshold was significantly lower in the TPs (t = -6.21, p < 0.001). Unpleasantness ratings after deep compression were significantly lower in the TPs compared with control points (t = -2.68, p < 0.05). Participants experienced greater relief at the TPs compared with control points (t = 2.01, p < 0.05), although the perceived pain did not differ between the two types of points. Conclusion We compared the properties of TPs and control points, and found that deep compression at TPs was associated with higher muscle tone and stiffness, lower unpleasantness ratings, and higher relief ratings compared with the control points. These findings suggest that, at least for some TPs, pain and pleasantness are simultaneously elicited by deep pressure stimulation.
Collapse
Affiliation(s)
- Seoyoung Lee
- Acupuncture and Meridian Science Research Center, Kyung Hee University, Seoul, Republic of Korea
| | - Heeyoung Moon
- Acupuncture and Meridian Science Research Center, Kyung Hee University, Seoul, Republic of Korea
| | - Yeonhee Ryu
- KM Science Research Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea
| | - In-Seon Lee
- Acupuncture and Meridian Science Research Center, Kyung Hee University, Seoul, Republic of Korea
| | - Younbyoung Chae
- Acupuncture and Meridian Science Research Center, Kyung Hee University, Seoul, Republic of Korea
| |
Collapse
|
18
|
Çevik Saldıran T, Kara İ, Kutlutürk Yıkılmaz S. Quantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strength. J Electromyogr Kinesiol 2022; 67:102718. [PMID: 36334405 DOI: 10.1016/j.jelekin.2022.102718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 10/10/2022] [Accepted: 10/19/2022] [Indexed: 12/13/2022] Open
Abstract
The primary objective of this study was to investigate the reliability of the myotonometer in the mechanical properties of the forearm muscles [m. extensor carpi radialis brevis (ECRB), and m. flexor carpi ulnaris (FCU)] in healthy individuals. The secondary objective was to investigate the relationship between the handgrip strength and mechanical properties of these forearm muscles. The mechanical properties (muscle tone, stiffness, and elasticity) of the ECRB and FCU were measured using the MyotonPRO device. Examiner 1 performed two sets of measurements with a time interval of 30 min to determine intra-examiner reliability. Examiner 2 performed measurements during the interval between the two sets of examiner 1. The intra- and inter-examiner reliabilities were excellent (ICC˃0.82) for muscle tone, stiffness, and elasticity of the FCU. Both intra- and inter-examiner reliability in the evaluation of ECRB muscle tone, elasticity, and stiffness was moderate to excellent (ICCs = 0.56-0.98). The muscle tone and stiffness properties of the FCU were positively correlated with the handgrip strength (p <.05). The study findings indicate that the MyotonPRO device is a reliable tool to quantify ECRB, and FCU muscles mechanical properties in healthy individuals.
Collapse
Affiliation(s)
- Tülay Çevik Saldıran
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bitlis Eren University, Bitlis, Turkey.
| | - İlke Kara
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bitlis Eren University, Bitlis, Turkey; Department of Physical Therapy and Rehabilitation, Institute of Health Sciences, Dokuz Eylul University, Izmir, Turkey
| | - Seval Kutlutürk Yıkılmaz
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Istanbul Medipol University, Istanbul, Turkey
| |
Collapse
|
19
|
Plehuna A, Green DA, Amirova LE, Tomilovskaya ES, Rukavishnikov IV, Kozlovskaya IB. Dry immersion induced acute low back pain and its relationship with trunk myofascial viscoelastic changes. Front Physiol 2022; 13:1039924. [PMID: 36311233 PMCID: PMC9606241 DOI: 10.3389/fphys.2022.1039924] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 09/26/2022] [Indexed: 08/12/2023] Open
Abstract
Microgravity induces spinal elongation and Low Back Pain (LBP) but the pathophysiology is unknown. Changes in paraspinal muscle viscoelastic properties may play a role. Dry Immersion (DI) is a ground-based microgravity analogue that induces changes in m. erector spinae superficial myofascial tissue tone within 2 h. This study sought to determine whether bilateral m. erector spinae tone, creep, and stiffness persist beyond 2 h; and if such changes correlate with DI-induced spinal elongation and/or LBP. Ten healthy males lay in the DI bath at the Institute of Biomedical Problems (Moscow, Russia) for 6 h. Bilateral lumbar (L1, L4) and thoracic (T11, T9) trunk myofascial tone, stiffness and creep (MyotonPRO), and subjective LBP (0-10 NRS) were recorded before DI, after 1h, 6 h of DI, and 30min post. The non-standing spinal length was evaluated on the bath lifting platform using a bespoke stadiometer before and following DI. DI significantly modulated m. erector spinae viscoelastic properties at L4, L1, T11, and T9 with no effect of laterality. Bilateral tissue tone was significantly reduced after 1 and 6 h DI at L4, L1, T11, and T9 to a similar extent. Stiffness was also reduced by DI at 1 h but partially recovered at 6 h for L4, L1, and T11. Creep was increased by DI at 1 h, with partial recovery at 6 h, although only T11 was significant. All properties returned to baseline 30 min following DI. Significant spinal elongation (1.17 ± 0.20 cm) with mild (at 1 h) to moderate (at 6 h) LBP was induced, mainly in the upper lumbar and lower thoracic regions. Spinal length increases positively correlated (Rho = 0.847, p = 0.024) with middle thoracic (T9) tone reduction, but with no other stiffness or creep changes. Spinal length positively correlated (Rho = 0.557, p = 0.039) with Max LBP; LBP failed to correlate with any m. erector spinae measured parameters. The DI-induced bilateral m. erector spinae tone, creep, and stiffness changes persist beyond 2 h. Evidence of spinal elongation and LBP allows suggesting that the trunk myofascial tissue changes could play a role in LBP pathogenesis observed in real and simulated microgravity. Further study is warranted with longer duration DI, assessment of IVD geometry, and vertebral column stability.
Collapse
Affiliation(s)
- Anastasija Plehuna
- King’s College London, Centre of Human & Applied Physiological Sciences, London, United Kingdom
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - David Andrew Green
- King’s College London, Centre of Human & Applied Physiological Sciences, London, United Kingdom
- Space Medicine Team, HRE-OM, European Astronaut Centre, European Space Agency, Cologne, Germany
- KBRwyle Laboratories GmbH, Cologne, Germany
| | - Liubov E. Amirova
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - Elena S. Tomilovskaya
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - Ilya V. Rukavishnikov
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - Inessa B. Kozlovskaya
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
20
|
Kurashina W, Iijima Y, Sasanuma H, Saito T, Takeshita K. Evaluation of muscle stiffness in adhesive capsulitis with Myoton PRO. JSES Int 2022; 7:25-29. [PMID: 36820433 PMCID: PMC9937826 DOI: 10.1016/j.jseint.2022.08.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Adhesive capsulitis (AC) is characterized by pain and limited range of motion, caused by stiffness of the joint capsule and coracohumeral ligament. On the other hand, there have been few reports on muscle stiffness in AC. The purpose of this study was to assess muscle stiffness in patients of AC with a portable and noninvasive device, Myoton PRO. We hypothesized that muscle stiffness around shoulder joint increases in AC. Methods At first, we surveyed correlation between Myoton PRO and shear wave elastography with phantoms. Second, reproducibility and repeatability of healthy volunteers with Myoton PRO were evaluated. Finally, muscle stiffness was measured in 40 patients who were diagnosed with AC. Muscle stiffness was quantitatively measured with Myoton PRO. We compared the stiffness of the anterior deltoid (AD), pectoralis major, and latissimus dorsi (LD) in AC patients on both the affected and nonaffected sides. Results Correlation coefficient in shear wave elastography and Myoton PRO was 0.99(P = .001). Reliability of intraoperator and interoperator with Myoton PRO was 0.9 or higher. Muscle stiffness values (N/m) of the AD, pectoralis major, and LD were 355 ± 61, 252 ± 54, 207 ± 51 in the affected sides and 328 ± 50, 252 ± 41, 186 ± 37 in the nonaffected sides, and the differences were significant in the AD and LD (P = .005, P = .002, respectively). Conclusions We used Myoton PRO to evaluate muscle stiffness in AC. The AD and LD muscles of AC patients were significantly stiffer on the affected side compared to the nonaffected side.
Collapse
Affiliation(s)
- Wataru Kurashina
- Department of Rehabilitation, Tochigi Medical Center Shimotsuga, Ohira, Tochigi, Japan,Graduate School of Medicine, Jichi Medical University, Tochigi, Japan
| | - Yuki Iijima
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan,Corresponding author: Yuki Iijima, MD, Department of Orthopaedic Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 3292740822, Japan.
| | - Hideyuki Sasanuma
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| | - Tomohiro Saito
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| | - Katsushi Takeshita
- Department of Orthopaedic Surgery, Jichi Medical University, Tochigi, Japan
| |
Collapse
|
21
|
Cruz-Montecinos C, Besomi M, Acevedo-Valenzuela N, Cares-Marambio K, Bustamante A, Guzmán-González B, Tapia-Malebrán C, Sanzana-Cuche R, Calatayud J, Méndez-Rebolledo G. Soleus muscle and Achilles tendon compressive stiffness is related to knee and ankle positioning. J Electromyogr Kinesiol 2022; 66:102698. [PMID: 36007467 DOI: 10.1016/j.jelekin.2022.102698] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 08/06/2022] [Accepted: 08/10/2022] [Indexed: 11/15/2022] Open
Abstract
Changes in fascicle length and tension of the soleus (SOL) muscle have been observed in humans using B-mode ultrasound to examine the knee from different angles. An alternative technique of assessing muscle and tendon stiffness is myometry, which is non-invasive, accessible, and easy to use. This study aimed to estimate the compressive stiffness of the distal SOL and Achilles tendon (AT) using myometry in various knee and ankle joint positions. Twenty-six healthy young males were recruited. The Myoton-PRO device was used to measure the compressive stiffness of the distal SOL and AT in the dominant leg. The knee was measured in two positions (90° of flexion and 0° of flexion) and the ankle joint in three positions (10° of dorsiflexion, neutral position, and 30° of plantar flexion) in random order. A three-way repeated-measures ANOVA test was performed. Significant interactions were found for structure × ankle position, structure × knee position, and structure × ankle position × knee position (p < 0.05). The AT and SOL showed significant increases in compressive stiffness with knee extension over knee flexion for all tested ankle positions (p < 0.05). Changes in stiffness relating to knee positioning were larger in the SOL than in the AT (p < 0.05). These results indicate that knee extension increases the compressive stiffness of the distal SOL and AT under various ankle joint positions, with a greater degree of change observed for the SOL. This study highlights the relevance of knee position in passive stiffness of the SOL and AT.
Collapse
Affiliation(s)
- Carlos Cruz-Montecinos
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile; Division of Research, Devolvement and Innovation in Kinesiology, Kinesiology Unit, San José Hospital, Northern Metropolitan Health Service, Santiago, Chile.
| | - Manuela Besomi
- Carrera de Kinesiología, Facultad de Medicina Clínica Alemana, Universidad del Desarrollo, Chile; School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Queensland, Australia
| | - Nicolás Acevedo-Valenzuela
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile
| | - Kevin Cares-Marambio
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile
| | - Alejandro Bustamante
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile
| | - Benjamín Guzmán-González
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile
| | - Claudio Tapia-Malebrán
- Department of Physical Therapy, Laboratory of Clinical Biomechanics, Faculty of Medicine, University of Chile, Santiago, Chile
| | - Rodolfo Sanzana-Cuche
- Department of Anatomy and Legal Medicine Faculty of Medicine, University of Chile, Chile; Facultad de Medicina y Ciencia, Universidad San Sebastián, Sede Los Leones, Chile
| | - Joaquín Calatayud
- Exercise Intervention for Health Research Group (EXINH-RG), Department of Physiotherapy, University of Valencia, Spain
| | | |
Collapse
|
22
|
Amirova L, Avdeeva M, Shishkin N, Gudkova A, Guekht A, Tomilovskaya E. Effect of Modulated Electromyostimulation on the Motor System of Elderly Neurological Patients. Pilot Study of Russian Currents Also Known as Kotz Currents. Front Physiol 2022; 13:921434. [PMID: 35923241 PMCID: PMC9339608 DOI: 10.3389/fphys.2022.921434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 06/24/2022] [Indexed: 11/13/2022] Open
Abstract
In this brief report, we present preliminary findings from a study of the use of electromyostimulation (EMS) in neurological patients. Assuming the approach to be sufficiently effective, we decided to investigate the motor system of elderly neurological patients before and after a course of Russian currents EMS, which were developed for Soviet athletes and cosmonauts. To this point, 19 patients—EMS (n = 11) and control (n = 8)—have successfully completed the study. The study included patients aged 60–90 years with confirmed walking and balance disorders with a history of chronic cerebral ischemia. Patients in the experimental group underwent a course of modulated EMS of the hip and shin muscles from 3 to 9 procedures. Preliminary results of the study showed good patient acceptance of EMS. After the course, the EMS group showed a significant improvement from baseline in the Tinetti Test (+1.4 points, p = 0.0045), Rivermead Mobility Index (+0.5 points, p = 0.0022), and Timed Up and Go Test (−1.2 s, p = 0.0053). There was also a significant improvement in balance quality of 8.6% (p = 0.04). Shin muscle strength, although trending positively, did not change significantly. There was also no change in hip and shin muscles’ tone. No significant changes were observed in the control group in the same tests. It can be concluded that stimulation of the hip and shin muscles with Russian (Kotz) currents has a positive effect on the motor system of elderly neurological patients. Significant effects with a course of short duration indicate that this EMS regimen is promising.
Collapse
Affiliation(s)
- Liubov Amirova
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems of the Russian Academy of Sciences, Moscow, Russia
- *Correspondence: Liubov Amirova,
| | - Maria Avdeeva
- Consultative and Diagnostic Department, Solovyov Scientific and Practical Psychoneurological Center of the Moscow Department of Health, Moscow, Russia
| | - Nikita Shishkin
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems of the Russian Academy of Sciences, Moscow, Russia
| | - Anna Gudkova
- Consultative and Diagnostic Department, Solovyov Scientific and Practical Psychoneurological Center of the Moscow Department of Health, Moscow, Russia
| | - Alla Guekht
- Consultative and Diagnostic Department, Solovyov Scientific and Practical Psychoneurological Center of the Moscow Department of Health, Moscow, Russia
| | - Elena Tomilovskaya
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems of the Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
23
|
Saldiran TÇ, Kara İ, Yikilmaz SK, Durgun M. Influence of Body Posture and Apnea Severity on the Tone and Elasticity of Upper Airway Muscles in Awake Patients With Obstructive Sleep Apnea: A Cross-Sectional Study. J Manipulative Physiol Ther 2022; 45:365-377. [PMID: 36192260 DOI: 10.1016/j.jmpt.2022.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 07/22/2022] [Accepted: 08/24/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVE The purpose of this study was to compare the effect of body posture and apnea severity on the tone, stiffness, and elasticity of upper airway muscles in awake patients with obstructive sleep apnea syndrome (OSAS). METHODS Eighty adult patients with OSAS from the Sleep Laboratory of the Bitlis State Hospital between April and December 2021 were included in the study. The tone, stiffness, and elasticity of the genioglossus and accessory muscles (sternocleidomastoid, masseter) were measured while the patients were awake, sitting upright, and in supine posture. According to polysomnography results and the Apnea-Hypopnea Index, patients were classified as mild, moderate, or severe OSAS. RESULTS There were 56 male (70%) and 24 female (30%) patients (age 45.0 ± 11.0 years). Tone of genioglossus, masseter, and sternocleidomastoid muscles were higher in supine than in sitting posture (all P < .05). There was no difference in elasticity scores of the bilateral genioglossus muscle in sitting and supine posture (P > .05). The elasticity scores of the sternocleidomastoid and masseter muscles were higher in sitting (all P < .05). An interaction effect of postural change and apnea severity was observed on stiffness scores of the genioglossus muscle (P < .05). CONCLUSION Results showed that the genioglossus muscle and accessory muscles take on the inspiratory load that develops with postural strain, regardless of the severity of apnea, in awake patients with OSAS. For participants measured in this study, accessory muscles supported respiration by increasing their elasticity.
Collapse
Affiliation(s)
- Tülay Çevik Saldiran
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Bitlis Eren University, Bitlis, Turkey.
| | - İlke Kara
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Dokuz Eylül University, İzmir, Turkey
| | - Seval Kutlutürk Yikilmaz
- Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Istanbul Medipol University, Istanbul, Turkey
| | - Mehmet Durgun
- Department of Pulmonary Disease, Bitlis State Hospital, Bitlis, Turkey
| |
Collapse
|
24
|
Bruno V, Sarasso P, Fossataro C, Ronga I, Neppi-Modona M, Garbarini F. The rubber hand illusion in microgravity and water immersion. NPJ Microgravity 2022; 8:15. [PMID: 35523786 PMCID: PMC9076892 DOI: 10.1038/s41526-022-00198-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 03/23/2022] [Indexed: 11/08/2022] Open
Abstract
Our body has evolved in terrestrial gravity and altered gravitational conditions may affect the sense of body ownership (SBO). By means of the rubber hand illusion (RHI), we investigated the SBO during water immersion and parabolic flights, where unconventional gravity is experienced. Our results show that unconventional gravity conditions remodulate the relative weights of visual, proprioceptive, and vestibular inputs favoring vision, thus inducing an increased RHI susceptibility.
Collapse
Affiliation(s)
- V Bruno
- MANIBUS Lab, Psychology Department, University of Turin, Turin, Italy
| | - P Sarasso
- BIP Lab, Department of Psychology, University of Turin, Turin, Italy.
| | - C Fossataro
- MANIBUS Lab, Psychology Department, University of Turin, Turin, Italy
| | - I Ronga
- MANIBUS Lab, Psychology Department, University of Turin, Turin, Italy
- BIP Lab, Department of Psychology, University of Turin, Turin, Italy
| | - M Neppi-Modona
- MANIBUS Lab, Psychology Department, University of Turin, Turin, Italy
- BIP Lab, Department of Psychology, University of Turin, Turin, Italy
- Neuroscience Institute of Turin (NIT), Turin, Italy
| | - F Garbarini
- MANIBUS Lab, Psychology Department, University of Turin, Turin, Italy
- Neuroscience Institute of Turin (NIT), Turin, Italy
| |
Collapse
|
25
|
BANERJEE SHIBSUNDAR, SADHUKHAN DEBOLEENA, ARUNACHALAKASI AROCKIARAJAN, SWAMINATHAN RAMAKRISHNAN. ANALYSIS OF INDUCED ISOMETRIC FATIGUING CONTRACTIONS IN BICEPS BRACHII MUSCLES USING MYOTONOMETRY AND SURFACE ELECTROMYOGRAPHIC MEASUREMENTS. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Viscoelastic properties of skeletal muscle tissue are known to be impacted by fatiguing contractions. In this study, an attempt has been made to utilize myotonometry for analyzing the relationship between muscle viscoelasticity and contractile behaviors in a fatiguing task. For this purpose, thirteen young healthy volunteers are recruited to perform the fatiguing isometric task and the time to task failure (TTF) is recorded. Myotonometric parameters and simultaneous surface electromyographic (sEMG) signals are recorded from the Biceps Brachii muscle of the flexed arm. The correlation between myotonometric parameters and TTF is further analyzed. Cross-validation with sEMG features is also performed. Stiffness of muscle has a positive correlation with TTF in the left hand ([Formula: see text]). Damping property of the nonfatigued muscle is positively associated with the fatigue-induced changes in amplitude features of sEMG signal in the right hand ([Formula: see text]). The normalized rate of change of mean frequency of sEMG signal has a positive correlation with stiffness values in both of the hands ([Formula: see text]). Muscle viscoelasticity is demonstrated to influence the progression of fatigue, although the difference in motor control due to handedness is also found to be an important factor. The results are promising to improve the understanding of the effect of muscle mechanics in fatigue-induced task failure.
Collapse
Affiliation(s)
- SHIB SUNDAR BANERJEE
- Non-Invasive Imaging and Diagnostic Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600 036, India
| | - DEBOLEENA SADHUKHAN
- Non-Invasive Imaging and Diagnostic Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600 036, India
| | - AROCKIARAJAN ARUNACHALAKASI
- Smart Material Characterization Lab, Solid Mechanics Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600 036, India
| | - RAMAKRISHNAN SWAMINATHAN
- Non-Invasive Imaging and Diagnostic Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600 036, India
| |
Collapse
|
26
|
Naczk A, Doś J, Górska-Doś M, Sibilski R, Gramza P, Gajewska E, Naczk M. Relationship between Viscoelastic Properties of Tissues and Bioimpedance Spectroscopy in Breast-Cancer-Related Lymphedema. J Clin Med 2022; 11:jcm11051294. [PMID: 35268385 PMCID: PMC8911425 DOI: 10.3390/jcm11051294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 02/17/2022] [Accepted: 02/24/2022] [Indexed: 11/16/2022] Open
Abstract
The aim of this study was to assess the relationship between the viscoelastic properties of tissues and breast-cancer-related lymphedema (BCRL). After a mastectomy, 46 females were allocated into a lymphedema group (L; n = 15, lymphedema occurred) and a control group (C; n = 31, lack of lymphedema). Bioimpedance spectroscopy was used to test BCRL. The mechanical properties of the tissues in both upper limbs were tested using myotonometry. In group L, tone, stiffness, relaxation time, and creep measured on the biceps brachii of the impaired limb significantly differed from the results on the unimpaired limb. In group C, the differences were not significant. Moreover, both tone and stiffness were inversely correlated with the level of lymphedema (r = −0.72 and r = −0.88, respectively), and both relaxation and creep were significantly related to the level of lymphedema (r = 0.71 and r = 0.59, respectively), when myotonometry was completed on the biceps brachii of the impaired limb in group L. The relationships were not significant in group C. Measurements of viscoelastic properties can provide useful information concerning lymphedema. Our findings suggest that significant correlations between selected mechanical properties of the tissues and BCRL can be used in BCRL detection and treatment.
Collapse
Affiliation(s)
- Alicja Naczk
- Faculty of Physical Culture in Gorzow Wielkopolski, University School of Physical Education in Poznan, Estkowskiego Street 13, 66-400 Gorzow Wielkopolski, Poland; (A.N.); (J.D.); (M.G.-D.)
| | - Janusz Doś
- Faculty of Physical Culture in Gorzow Wielkopolski, University School of Physical Education in Poznan, Estkowskiego Street 13, 66-400 Gorzow Wielkopolski, Poland; (A.N.); (J.D.); (M.G.-D.)
- Department of Oncological Physiotherapy, Greater Poland Cancer Centre, Garbary Street 15, 61-866 Poznan, Poland
| | - Magdalena Górska-Doś
- Faculty of Physical Culture in Gorzow Wielkopolski, University School of Physical Education in Poznan, Estkowskiego Street 13, 66-400 Gorzow Wielkopolski, Poland; (A.N.); (J.D.); (M.G.-D.)
| | - Robert Sibilski
- Institute of Medical Sciences, Collegium Medicum, University of Zielona Gora, Licealna Street 9, 65-417 Zielona Gora, Poland;
| | - Piotr Gramza
- Association of Lubusz Innovation Network, Teatralna Street 49, 66-400 Gorzow Wielkopolski, Poland;
| | - Ewa Gajewska
- Department of Developmental Neurology, Poznan University of Medical Sciences, 49 Przybyszewskiego Street, 60-355 Poznan, Poland;
| | - Mariusz Naczk
- Institute of Health Sciences, Collegium Medicum, University of Zielona Gora, Licealna Street 9, 65-417 Zielona Gora, Poland
- Correspondence:
| |
Collapse
|
27
|
Nguyen AP, Detrembleur C, Fisette P, Selves C, Mahaudens P. MyotonPro Is a Valid Device for Assessing Wrist Biomechanical Stiffness in Healthy Young Adults. Front Sports Act Living 2022; 4:797975. [PMID: 35265831 PMCID: PMC8899712 DOI: 10.3389/fspor.2022.797975] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 01/26/2022] [Indexed: 12/03/2022] Open
Abstract
Background The MyotonPro is a portable device for measuring biomechanical and viscoelastic properties in superficial soft tissues. The aims of this study are firstly to validate the MyotonPro compared to a reliable gold-standard frame and secondly to observe the influence of MyotonPro measurement on the total wrist viscoelasticity. Methods Three silicone polymers with different elastic properties were assessed with the MyotonPro and with a reference rheometer (Universal Tribometer Mod). Then, a free oscillations method was used to measure the passive elastic and viscous stiffness of the wrist and compared to MyotonPro forearm measurements. Results A one-way ANOVA demonstrated the validity of the MyotonPro's stiffness (p = 0.001), decrement (p < 0.001), and relaxation (p = 0.008) parameters for measuring the elastic stiffness (k) of the three polymers. The MyotonPro parameters demonstrated excellent reliability on the forearm. Proximal and distal anterior myofascial measurements of the MyotonPro were moderately correlated to the elastic stiffness (p = 0.0027-0.0275, absolute r = from 0.270 to 0.375) of the wrist while the postero-distal myofascial tissues of the forearm demonstrated a moderate correlation with the viscous stiffness of the wrist (p = 0.0096-0.0433, absolute r = from 0.257 to 0.326). Discussion The MyotonPro is a valid device for measuring elastic stiffness as well as a portable, affordable, and easy-to-use tool for quantifying the biomechanical properties and viscoelasticity of myofascial tissue in healthy subjects.
Collapse
Affiliation(s)
- Anh Phong Nguyen
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Christine Detrembleur
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Paul Fisette
- Institute of Mechanics, Materials and Civil Engineering, Mechatronic, Electrical Energy and Dynamic Systems, Catholic University of Louvain, Louvain-la-Neuve, Belgium
| | - Clara Selves
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
- Service de Médecine Physique et Réadaptation, Cliniques Universitaires Saint-Luc, Woluwe-Saint-Lambert, Belgium
| | - Philippe Mahaudens
- Neuromusculoskeletal Laboratory, Institut de Recherche Expérimentale et Clinique, Catholic University of Louvain, Louvain-la-Neuve, Belgium
- Service de Médecine Physique et Réadaptation, Cliniques Universitaires Saint-Luc, Woluwe-Saint-Lambert, Belgium
| |
Collapse
|
28
|
Wu Z, Ye X, Ye Z, Hong K, Chen Z, Wang Y, Li C, Li J, Huang J, Zhu Y, Lu Y, Liu W, Xu X. Asymmetric Biomechanical Properties of the Paravertebral Muscle in Elderly Patients With Unilateral Chronic Low Back Pain: A Preliminary Study. Front Bioeng Biotechnol 2022; 10:814099. [PMID: 35223786 PMCID: PMC8866935 DOI: 10.3389/fbioe.2022.814099] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/17/2022] [Indexed: 11/13/2022] Open
Abstract
Background: Clinical incidences of chronic low back pain among the elderly are increasing. However, studies have not fully elucidated on changes in biomechanical properties of paravertebral muscles in patients with unilateral chronic low back pain. We evaluated the changes in biomechanical properties of painful and non-painful paravertebral muscles in elderly patients with unilateral chronic low back pain.Methods: Biomechanical properties of paravertebral muscles, including muscle tone and stiffness, in elderly patients with unilateral chronic low back pain were measured using MyotonPRO. Lumbar Lordosis and Sacral Slope were measured by magnetic resonance imaging. Cross-sectional areas of paravertebral muscles were evaluated using ImageJ software version 1.53. Chronic low back pain severity was assessed by Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI) scores. The correlations between VAS scores, ODI scores, Lumbar Lordosis, Sacral Slope, cross-sectional areas (painful side), disease duration, and biomechanical properties of paravertebral muscles in the painful side were analyzed.Results: A total of 60 elderly patients with unilateral chronic low back pain were enrolled in this study. The muscle tone and stiffness of paravertebral muscles on the painful side were significantly higher than those on the non-painful side (p < .05). Cross-sectional areas of paravertebral muscles on the painful side at the L3 level were smaller than those of the non-painful side (p < .05). The VAS scores and ODI scores were significantly positively correlated with muscle tone and stiffness of paravertebral muscles on the painful side (p < .05 and p < .01, respectively). There were no significant correlations between disease duration, cross-sectional areas (painful side), Lumbar Lordosis, or Sacral Slope and muscle tone and stiffness of paravertebral muscles on the painful side (p > .05).Conclusion: In elderly patients with unilateral chronic low back pain, muscle tone and stiffness of paravertebral muscles on the painful side are higher than for those on the non-painful side. The asymmetry of biomechanical properties of paravertebral muscles is associated with severity of chronic low back pain.
Collapse
Affiliation(s)
- Zugui Wu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiangling Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Zixuan Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Kunhao Hong
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Zehua Chen
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Yi Wang
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Congcong Li
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Junyi Li
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Jinyou Huang
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Yue Zhu
- Baishui Health Center, Qujing, China
| | - Yanyan Lu
- Luoyang Orthopedic Hospital Of Henan Province (Orthopedic Hospital of Henan Province), Zhengzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| | - Wengang Liu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| | - Xuemeng Xu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
- *Correspondence: Xuemeng Xu, ; Wengang Liu, ; Yanyan Lu,
| |
Collapse
|
29
|
Chang TT, Zhu YC, Li Z, Li F, Li YP, Guo JY, Wang XQ, Zhang ZJ. Modulation in the Stiffness of Specific Muscles of the Quadriceps in Patients With Knee Osteoarthritis and Their Relationship With Functional Ability. Front Bioeng Biotechnol 2022; 9:781672. [PMID: 35223811 PMCID: PMC8870124 DOI: 10.3389/fbioe.2021.781672] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/13/2021] [Indexed: 11/13/2022] Open
Abstract
Deficits in the flexibility of the quadriceps are one of the risk factors for developing knee joint disorders. No studies have investigated the changes in the stiffness of the quadriceps muscle among patients with knee osteoarthritis (OA). Therefore, the purpose of this study was to investigate changes in the stiffness of specific-muscle of the quadriceps in patients with knee OA and their relationship with functional ability. Twenty-five patients with knee OA and 25 healthy, asymptomatic subjects were recruited in this study. The stiffness of the vastus lateralis (VL), vastus medialis (VM) and rectus femoris (RF) in all participants was evaluated using MyotonPRO at 60° and 90° flexion of the knee joint. The results of this study showed a greater VL stiffness in patients with knee OA than in healthy subjects at both 60° and 90° of knee flexion (p < 0.05). Significant differences in VL, VM and RF stiffness were obtained at different knee joint angles in individuals with and without knee OA (p < 0.05). In addition, there was a positive correlation between VL stiffness and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores in patients with Knee OA (60° of knee flexion: r = 0.508, p = 0.010; 90° of knee flexion: r = 0.456, p = 0.022). These results indicate that there is an increase in VL stiffness in patients with knee OA compared with healthy, asymptomatic subjects, and the quadriceps stiffness was increased with knee flexion in both healthy subjects and patients with knee OA. VL stiffness is associated with WOMAC scores in patients with knee OA.
Collapse
Affiliation(s)
- Tian-Tian Chang
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Yuan-Chun Zhu
- Department of Sport Rehabilitation, Shanghai University of Sport, Shanghai, China
| | - Zhe Li
- The First Clinical Medical School, Shaanxi University of Chinese Medicine, Xi’an, China
| | - Feng Li
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Ya-Peng Li
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Jia-Yi Guo
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| | - Xue-Qiang Wang
- Department of Sport Rehabilitation, Shanghai University of Sport, Shanghai, China
- Department of Rehabilitation Medicine, Shanghai Shangti Orthopaedic Hospital, Shanghai, China
| | - Zhi-Jie Zhang
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
- *Correspondence: Zhi-Jie Zhang,
| |
Collapse
|
30
|
Lee MT, Wu CY, Chen CW, Cheng HL, Chen CC, Hsieh YW. Age and sex differences in the biomechanical and viscoelastic properties of upper limb muscles in middle-aged and older adults: A pilot study. J Biomech 2022; 134:111002. [DOI: 10.1016/j.jbiomech.2022.111002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 12/24/2021] [Accepted: 02/12/2022] [Indexed: 10/19/2022]
|
31
|
Sichting F, Kram NC, Legerlotz K. An Identical Twin Study on Human Achilles Tendon Adaptation: Regular Recreational Exercise at Comparatively Low Intensities Can Increase Tendon Stiffness. Front Physiol 2022; 12:777403. [PMID: 35069241 PMCID: PMC8766644 DOI: 10.3389/fphys.2021.777403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 12/13/2021] [Indexed: 11/13/2022] Open
Abstract
Achilles tendon adaptation is a key aspect of exercise performance and injury risk prevention. However, much debate exists about the adaptation of the Achilles tendon in response to exercise activities. Most published research is currently limited to elite athletes and selected exercise activities. Also, existing studies on tendon adaptation do not control for genetic variation. Our explorative cross-sectional study investigated the effects of regular recreational exercise activities on Achilles tendon mechanical properties in 40 identical twin pairs. Using a handheld oscillation device to determine Achilles tendon mechanical properties, we found that the Achilles tendon appears to adapt to regular recreational exercise at comparatively low intensities by increasing its stiffness. Active twins showed a 28% greater Achilles tendon stiffness than their inactive twin (p < 0.05). Further, our research extends existing ideas on sport-specific adaptation by showing that tendon stiffness seemed to respond more to exercise activities that included an aerial phase such as running and jumping. Interestingly, the comparison of twin pairs revealed a high variation of Achilles tendon stiffness (305.4–889.8 N/m), and tendon adaptation was only revealed when we controlled for genetic variance. Those results offer new insights into the impact of genetic variation on individual Achilles tendon stiffness, which should be addressed more closely in future studies.
Collapse
Affiliation(s)
- Freddy Sichting
- Department of Human Locomotion, Chemnitz University of Technology, Chemnitz, Germany
| | - Nicolai C Kram
- Department of Human Locomotion, Chemnitz University of Technology, Chemnitz, Germany
| | - Kirsten Legerlotz
- Movement Biomechanics, Institute of Sport Sciences, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
32
|
Hamilton RI, Garden CL, Brown SJ. Immediate effect of a spinal mobilisation intervention on muscle stiffness, tone and elasticity in subjects with lower back pain – A randomized cross-over trial. J Bodyw Mov Ther 2022; 29:60-67. [DOI: 10.1016/j.jbmt.2021.09.032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 08/01/2021] [Accepted: 09/24/2021] [Indexed: 11/29/2022]
|
33
|
Do Y, Lall PS, Lee H. Assessing the Effects of Aging on Muscle Stiffness Using Shear Wave Elastography and Myotonometer. Healthcare (Basel) 2021; 9:healthcare9121733. [PMID: 34946459 PMCID: PMC8700831 DOI: 10.3390/healthcare9121733] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/10/2021] [Accepted: 12/13/2021] [Indexed: 12/05/2022] Open
Abstract
The current study investigated the differences in muscle stiffness between older and young adults at rest and during contraction. We also evaluated the differences in muscle stiffness assessments using a myotonometer (MyotonPRO) and shear wave elastography (SWE). Twenty-two older adults (mean age, 66.6 ± 1.6 years) and 23 young adults (mean age, 66.6 ± 1.6 years) participated in this study. Muscle stiffness of the tibialis anterior (TA) and medial gastrocnemius (MG) muscles at rest and during contraction were measured using SWE and the MyotonPRO. The stiffness increase rate (SIR) was also calculated to determine the absolute stiffness difference. The mean muscle stiffness of the TA and MG muscles was significantly lower in older adults than in young adults at rest and during contraction (p < 0.05). Similarly, the SIR values of the TA and MG were significantly lower in older adults than in young adults (p < 0.05). Our results indicate that both instruments could be used to quantify muscle stiffness changes and serve as a cornerstone for assessing aging-related losses in muscle function. Stiffness measures may help exercise professionals to develop an in-depth understanding of muscle impairment at the tissue level.
Collapse
Affiliation(s)
| | | | - Haneul Lee
- Correspondence: ; Tel.: +(82)-32-820-4335; Fax: +(82)-32-820-4420
| |
Collapse
|
34
|
Rosicka K, Mierzejewska-Krzyżowska B, Mrówczyński W. Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body. Skin Res Technol 2021; 28:236-245. [PMID: 34751466 PMCID: PMC9907614 DOI: 10.1111/srt.13116] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 10/16/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND There is still a lack of clinically practical device, which allows to perform rapid and accurate examination of the skin condition. For this reason, suitability of the MyotonPRO for the assessment of skin biomechanical and viscoelastic parameters was evaluated in this study. The aim of the study was to establish the reference values of five parameters measured by MyotonPRO various locations of human skin. MATERIALS AND METHODS Oscillation frequency, dynamic stiffness, logarithmic decrement, mechanical stress relaxation and creep were measured at three different skin locations (clavicula, volar forearm and shin), using L-shape short and medium arm probes in 32 young female volunteers. Mean values of obtained parameters recorded by both probes were compared among three skin locations while reliabilities of measurements were assessed. Additionally, relationships between all recorded parameters were examined RESULTS: There were no statistically significant differences between the mean values of five measured parameters obtained with both probes in all investigated areas. However, statistically significant differences of mean values of almost all parameters measured among three places examined were found. Despite considerable differences in mean values of obtained parameters, there were visible strong correlations between some studied parameters in all three investigated areas of skin. CONCLUSION It was demonstrated in all locations studied that the higher value of oscillation frequency corresponds to the higher value of dynamic stiffness, moreover such tissue recovers faster to its initial shape, and it was characterized by lower creep values. Such results indicate the existence of identical relationships between the same studied parameters in different areas of skin.
Collapse
Affiliation(s)
- Katarzyna Rosicka
- Department of Biological Sciences, Faculty of Physical Culture, Poznań University of Physical Education, Gorzów Wielkopolski, Poland
| | - Barbara Mierzejewska-Krzyżowska
- Department of Biological Sciences, Faculty of Physical Culture, Poznań University of Physical Education, Gorzów Wielkopolski, Poland
| | - Włodzimierz Mrówczyński
- Department of Neurobiology, Faculty of Health Sciences, Poznań University of Physical Education, Poznań, Poland
| |
Collapse
|
35
|
García-Muñoz C, Cortés-Vega MD, Hernández-Rodríguez JC, Fernández-Seguín LM, Escobio-Prieto I, Casuso-Holgado MJ. Immersive Virtual Reality and Vestibular Rehabilitation in Multiple Sclerosis: Case Report. JMIR Serious Games 2021; 10:e31020. [PMID: 34766551 PMCID: PMC8892276 DOI: 10.2196/31020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/07/2021] [Accepted: 10/12/2021] [Indexed: 02/06/2023] Open
Abstract
Background Dizziness and imbalance are common and disabling symptoms in patients with multiple sclerosis (MS) and are caused by a central, peripheral, or mixed vestibulopathy. Central vestibular disorder is the most frequently reported vestibular problem in the MS population due to demyelination. Vestibular rehabilitation ameliorates these symptoms and their repercussions and improves quality of life. Immersive virtual reality (VRi) is an emerging tool in this field; however, no previous research has been performed studying its effects in MS. Objective The aim of this study was to apply a VRi vestibular training protocol to a patient with MS and assess the effects induced by the experimental intervention. Methods This case study included a 54-year-old woman with relapsing-remitting MS. We developed a standardized VRi exercise protocol for vestibular rehabilitation based on the gold-standard Cawthorne-Cooksey vestibular training protocol. The 20-session intervention was made up of 10 initial sessions and 10 advanced sessions. Each 50-minute session was performed two to three times per week for 7 weeks. Four evaluations were carried out over the study period: at baseline (T0), between initial and advances phases (T1), postintervention (T2), and 1 month after the experimental procedure (T3). The research outcomes were dizziness, balance, gait, impact of fatigue, quality of life, repercussions in muscular tone, and usability of the head-mounted display device. Results After implementing the VRi vestibular protocol, improvements were seen in the following patient parameters: Dizziness Handicap Inventory score (62 points at T0; 4 points at T2); Berg Balance Scale score (47 points at T0; 54 points at T2); instrumented Timed Up and Go time (8.35 seconds at T0; 5.57 seconds at T2); muscular tone of the erector spinae, rectus femoris, and soleus; Modified Fatigue Impact Scale score (61 points at T0; 37 points at T2); and Multiple Sclerosis Quality of Life-54 values (67.16% in the physical health area at T2; 33.56% in the mental health area at T2). The patient rated the usability of the system as 90%, based on the System Usability Scale, and gave the system a grade of A. Conclusions Although further research is needed, this study provided initial evidence that the first VRi vestibular protocol for the MS population can improve dizziness, balance, gait, impact of fatigue, quality of life, and muscular tone through an exergame intervention. This study may help establish a standardized VRi protocol for vestibular rehabilitation.
Collapse
Affiliation(s)
- Cristina García-Muñoz
- Physiotherapy Department. Faculty of Nursing, Physiotherapy and Podiatry., University of Seville, C/ Avicena S/N, Seville, ES
| | - María-Dolores Cortés-Vega
- Physiotherapy Department. Faculty of Nursing, Physiotherapy and Podiatry., University of Seville, C/ Avicena S/N, Seville, ES
| | | | - Lourdes M Fernández-Seguín
- Physiotherapy Department. Faculty of Nursing, Physiotherapy and Podiatry., University of Seville, C/ Avicena S/N, Seville, ES
| | - Isabel Escobio-Prieto
- Physiotherapy Department. Faculty of Nursing, Physiotherapy and Podiatry., University of Seville, C/ Avicena S/N, Seville, ES
| | - María Jesús Casuso-Holgado
- Physiotherapy Department. Faculty of Nursing, Physiotherapy and Podiatry., University of Seville, C/ Avicena S/N, Seville, ES
| |
Collapse
|
36
|
Wu Z, Wang Y, Ye Z, Guan Y, Ye X, Chen Z, Li C, Chen G, Zhu Y, Du J, Chen G, Liu W, Xu X. Effects of Age and Sex on Properties of Lumbar Erector Spinae in Healthy People: Preliminary Results From a Pilot Study. Front Physiol 2021; 12:718068. [PMID: 34616306 PMCID: PMC8488426 DOI: 10.3389/fphys.2021.718068] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 08/17/2021] [Indexed: 12/04/2022] Open
Abstract
Background: The influences of age and sex on properties of lumbar erector spinae have not been previously studied. Changes in the performance of lumbar erector spinae properties associated with age represent a valuable indicator of risk for lower-back-related disease. Objective: To investigate the lumbar erector spinae properties with regard to age and sex to provide a reference dataset. Methods: We measured muscle tone and stiffness of the lumbar erector spinae (at the L3–4 level) in healthy men and women (50 young people, aged 20–30 years; 50 middle-aged people, aged 40–50 years; and 50 elderly people, aged 65–75 years) using a MyotonPRO device. Results: In general, there are significant differences in muscle tone and stiffness among young, middle-aged, and elderly participants, and there were significant differences in muscle tone and stiffness between men and women, and there was no interaction between age and sex. The muscle tone and stiffness of the elderly participants were significantly higher than those of the middle-aged and young participants (P < 0.01), and the muscle tone and stiffness of the middle-aged participants were significantly higher than those of the young participants (P < 0.01). In addition, the muscle tone and stiffness of men participants were significantly higher than that of women participants (P < 0.01). Conclusion: Our results indicate that muscle tone and stiffness of the lumbar erector spinae increase with age. The muscle tone and stiffness of the lumbar erector spinae in men are significantly higher than in women. The present study highlights the importance of considering age and sex differences when assessing muscle characteristics of healthy people or patients.
Collapse
Affiliation(s)
- Zugui Wu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Yi Wang
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Zixuan Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Yingxing Guan
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xiangling Ye
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Zehua Chen
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Congcong Li
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Guoqian Chen
- Zhejiang Provincial Hospital of Chinese Medicine, Hangzhou, China
| | - Yue Zhu
- Baishui Health Center, Qujing, China
| | - Jianping Du
- Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Guocai Chen
- Foshan Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Wengang Liu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.,Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| | - Xuemeng Xu
- The Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.,Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China
| |
Collapse
|
37
|
Fan T, Zhou X, He P, Zhan X, Zheng P, Chen R, Li R, Li R, Wei M, Zhang X, Huang G. Effects of Radial Extracorporeal Shock Wave Therapy on Flexor Spasticity of the Upper Limb in Post-stroke Patients: Study Protocol for a Randomized Controlled Trial. Front Neurol 2021; 12:712512. [PMID: 34566855 PMCID: PMC8459743 DOI: 10.3389/fneur.2021.712512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/03/2021] [Indexed: 11/15/2022] Open
Abstract
Background: Flexor spasticity of the upper limb is common in poststroke patients and seriously affects the recovery of upper limb function. However, there are no standard management protocols for this condition. Radial extracorporeal shock wave therapy (rESWT) is widely used for various diseases, some studies reported the effects of ESWT on reducing spasticity, but the mechanism of ESWT to reduce spasticity by affecting the excitability of stretch reflex or non-neural rheological components in spastic muscles or both is not yet clear. A large randomized controlled trial with comprehensive evaluation indicators is still needed. The study is to observe the effect of rESWT on flexor spasticity of the upper limb after stroke and explore its mechanism. Methods: A prospective, randomized, double-blind controlled trial is to be performed. One hundred participants will be recruited from the Inpatient Department of Zhujiang Hospital. Eligible patients will be randomly allocated to either receive three sessions of active rESWT (group A) or sham-placebo rESWT (group B) with 3-day intervals between each session. Assessment will be performed at baseline and at 24 h after each rESWT (t1, t2, and t3). The primary assessment outcome will be the Modified Ashworth Scale, and other assessments include surface electromyography, MyotonPRO digital muscle function evaluation, and infrared thermal imaging. All data will be analyzed using intention-to-treat principles. Multiple imputation by chained equations will be used to address missing data caused by loss to follow-up and nonresponses. Per protocol, analyses will also be performed on the participants who complete other assessments. Statistical analysis will be performed using SPSS software (version 20.0) and the significance level set at p < 0.05. Discussion: This trial aims to analyze the application of rESWT for the management of spasticity after stroke via appropriate assessments. We hypothesized that after receiving active rESWT, patients would show greater improvement of upper limb muscles compared with patients within the sham-placebo group. The rESWT would be an alternative to traditional methods, and the results of this study may provide support for the further study of potential mechanisms. Clinical Trial Registration:www.chictr.org.cn, identifier: ChiCTR1800016144.
Collapse
Affiliation(s)
- Tao Fan
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China.,School of Rehabilitation Medicine, Southern Medical University, Guangzhou, China
| | - Xiangying Zhou
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Peichen He
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Xiaojia Zhan
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Peng Zheng
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Rong Chen
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Rongdong Li
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Rihui Li
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Mingyang Wei
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Xue Zhang
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
| | - Guozhi Huang
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China.,School of Rehabilitation Medicine, Southern Medical University, Guangzhou, China
| |
Collapse
|
38
|
Hu H, Chen Y, Wang X, Lo WLA, Li L. Quantifying the Changes of Mechanical and Electrical Properties of Paralyzed Muscle in Survivors With Cervical Spinal Cord Injury. Front Neurol 2021; 12:720901. [PMID: 34566864 PMCID: PMC8455836 DOI: 10.3389/fneur.2021.720901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Accepted: 07/19/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Survivors with spinal cord injury (SCI) have neuromuscular deficits such as muscle atrophy that lead to functional impairments. This study utilized myotonometry and electrical impedance myography (EIM) to quantitatively evaluate the changes in muscle mechanical properties and compositions after SCI. Methods: This study adopted a cross-sectional design. Eighteen SCI patients and 18 healthy individuals were recruited. The outcome measures were: (1) The myotonometer measured muscle mechanical parameters of oscillation frequency (freq), dynamic stiffness, logarithmic decrement (decr), mechanical stress relaxation time, and indication of creep. (2) The electrical impedance myography measured parameters of resistance (R), reactance (X), and phase angle (θ). (3) muscle strength (maxForce); (4) clinical scales of Manual Muscle Testing (MMT) and modified Ashworth scale (MAS). All outcome measures were compared between the bicep brachii muscle of the weaker side of the SCI group and the non-dominate side of the healthy group. Correlation analysis was performed at quantitative data and clinical scales. Results: Freq, stiffness, and maxForce of the SCI group were significantly lower (p < 0.01) than those of the healthy control. The relaxation time and creep were significantly higher in the SCI group than in the control group. Significant differences of R and Xc were observed between the two groups. Significant correlation was observed between freq, stiffness, and months past injury, and between Xc, creep, and relaxation time. Conclusions: Reduced muscle tone and stiffness might relate to muscle atrophy, and higher relax time and creep may be caused by poor contractile ability. The changes in EIM parameters could indirectly reflect the muscle cell size, and fatty and connective tissue alterations. These findings support the feasibility of myotonometer and EIM to quantify muscle mechanical and intrinsic properties in patients with SCI. The results could facilitate the understanding of neuromuscular changes that are related to functional impairments.
Collapse
Affiliation(s)
- Huijing Hu
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| | - Yingyue Chen
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| | - Xiaoyun Wang
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| | - Wai Leung Ambrose Lo
- Department of Rehabilitation Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Le Li
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, China
| |
Collapse
|
39
|
Rosicka K, Hill M, Wdowski MM. Skin anisotropy: Finding the optimal incision line for volar forearm in males and females. J Mech Behav Biomed Mater 2021; 124:104805. [PMID: 34474321 DOI: 10.1016/j.jmbbm.2021.104805] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE Proper understanding of skin biomechanics, viscoelasticity and investigation of skin tension vectors is necessary to find optimal incision lines. Great tension across a healing wound after any surgical procedure might lead to forming hypertrophic scars. The aim of the study was to investigate tension lines in volar forearm skin in young males and females, in order to ensure best incision line. METHODS Five biomechanical and viscoelastic parameters were measured using a hand-held myotonometer: Oscillation Frequency [Hz], Dynamic Stiffness [N/m], Logarithmic Decrement of tissue's natural oscillation, Mechanical Stress Relaxation Time [ms], and Creep. Measurements were taken in four different directions; Along Forearm, Across Forearm, Along Langer's Line and Across Langer's Line. RESULTS Significant main effects for direction were found for Oscillation Frequency (p < 0.001, η2 = 0.371) [Hz], Dynamic Stiffness (p < 0.001, η2 = 0.522) [N/m], Logarithmic Decrement (p < 0.001, η2 = 0.083), Mechanical Stress Relaxation Time (p < 0.001, η2 = 0.494) [ms] and Creep (p < 0.001, η2 = 0.480). For each parameter except for logarithmic decrement results obtained Along Langers Line and Across Forearm were significantly different to Across Langers Line and Along Forearm (p < 0.001, d = -2.76 - 2.66). Significant main effects for sex were found for logarithmic decrement Along Forearm (p < 0.001, d = 1.698) and Across Langer's Line (p = 0.021, d = 1.697). CONCLUSIONS Our results suggested that optimal incision line for this age group in males and females could potentially be performed diagonally i.e. Across Langer's Line or parallel i.e. Along Forearm to forearm axis. These directions would provide the lowest tension across a healing wound and possibly minimalize the risk of hypertrophic scarring post incision.
Collapse
Affiliation(s)
- K Rosicka
- Department of Biological Sciences, Faculty of Physical Culture in Gorzów Wlkp., Poznań University of Physical Education, Gorzów Wlkp, Poland.
| | - M Hill
- Centre for Sport, Exercise and Life Sciences, School of Life Sciences, Coventry University, United Kingdom
| | - M M Wdowski
- Centre for Sport, Exercise and Life Sciences, School of Life Sciences, Coventry University, United Kingdom
| |
Collapse
|
40
|
Amirova LE, Plehuna A, Rukavishnikov IV, Saveko AA, Peipsi A, Tomilovskaya ES. Sharp Changes in Muscle Tone in Humans Under Simulated Microgravity. Front Physiol 2021; 12:661922. [PMID: 34025451 PMCID: PMC8134537 DOI: 10.3389/fphys.2021.661922] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Accepted: 03/26/2021] [Indexed: 11/17/2022] Open
Abstract
A decrease in muscle tone induced by space flight requires a standardized assessment of changes to control the state of the neuromuscular system. This study is a step toward the development of a unified protocol, aimed at determining the initial effect of the presence or withdrawal of support on muscle tone, the effects of a 2-h supportlessness in Dry Immersion (DI) experiments, and the changes in muscle tone depending on the site of measurement. To perform measurements of changes in muscle tone, we used a MyotonPRO device. The list of muscles that we assessed includes: trunk – mm. deltoideus posterior, trapezius, erector spinae; leg – mm. biceps femoris, rectus femoris, tibialis anterior, soleus, gastrocnemius; foot – m. flexor digitorum brevis, tendo Achillis, aponeurosis plantaris. The study involved 12 healthy volunteers (6 men, 6 women) without musculoskeletal disorders and aged 32.8 ± 1.6 years. At the start of DI, there was a significant decrease in muscle tone of the following muscles: mm. tibialis anterior (−10.9%), soleus (−9.6%), erector spinae (−14.4%), and the tendo Achillis (−15.3%). The decrease continued to intensify over the next 2 h. In contrast, the gastrocnemius muscle demonstrated an increase in muscle tone (+7.5%) 2 h after the start of DI compared to the immediate in-bath baseline. Muscle tone values were found to be site-dependent and varied in different projections of mm. erector spinae and soleus. In previous experiments, we observed a high sensitivity of the myotonometry technique, which was confirmed in this study. To make it possible to compare data from different studies, a standardized protocol for measuring muscle tone for general use in gravitational physiology needs to be developed.
Collapse
Affiliation(s)
- Liubov E Amirova
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | - Anastasija Plehuna
- King's College London, Centre of Human & Applied Physiological Sciences, London, United Kingdom
| | - Ilya V Rukavishnikov
- Department of Medical Support for Spaceflight, Institute of Biomedical Problem of Russian Academy of Science, Moscow, Russia
| | - Alina A Saveko
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| | | | - Elena S Tomilovskaya
- Laboratory of Gravitational Physiology of the Sensorimotor System, Institute of Biomedical Problems, Russian Academy of Sciences, Moscow, Russia
| |
Collapse
|
41
|
Basti A, Yalçin M, Herms D, Hesse J, Aboumanify O, Li Y, Aretz Z, Garmshausen J, El-Athman R, Hastermann M, Blottner D, Relógio A. Diurnal variations in the expression of core-clock genes correlate with resting muscle properties and predict fluctuations in exercise performance across the day. BMJ Open Sport Exerc Med 2021; 7:e000876. [PMID: 33680499 PMCID: PMC7878143 DOI: 10.1136/bmjsem-2020-000876] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/25/2021] [Indexed: 12/14/2022] Open
Abstract
Objectives In this study, we investigated daily fluctuations in molecular (gene expression) and physiological (biomechanical muscle properties) features in human peripheral cells and their correlation with exercise performance. Methods 21 healthy participants (13 men and 8 women) took part in three test series: for the molecular analysis, 15 participants provided hair, blood or saliva time-course sampling for the rhythmicity analysis of core-clock gene expression via RT-PCR. For the exercise tests, 16 participants conducted strength and endurance exercises at different times of the day (9h, 12h, 15h and 18h). Myotonometry was carried out using a digital palpation device (MyotonPRO), five muscles were measured in 11 participants. A computational analysis was performed to relate core-clock gene expression, resting muscle tone and exercise performance. Results Core-clock genes show daily fluctuations in expression in all biological samples tested for all participants. Exercise performance peaks in the late afternoon (15–18 hours for both men and women) and shows variations in performance, depending on the type of exercise (eg, strength vs endurance). Muscle tone varies across the day and higher muscle tone correlates with better performance. Molecular daily profiles correlate with daily variation in exercise performance. Conclusion Training programmes can profit from these findings to increase efficiency and fine-tune timing of training sessions based on the individual molecular data. Our results can benefit both professional athletes, where a fraction of seconds may allow for a gold medal, and rehabilitation in clinical settings to increase therapy efficacy and reduce recovery times.
Collapse
Affiliation(s)
- Alireza Basti
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Systems Medicine and Bioinformatics, Department of Human Medicine, MSH Medical School Hamburg, Hamburg, Germany
| | - Müge Yalçin
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - David Herms
- Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Karate Department, Berliner Turn- und Sportclub e.V, Berlin, Germany
| | - Janina Hesse
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Systems Medicine and Bioinformatics, Department of Human Medicine, MSH Medical School Hamburg, Hamburg, Germany
| | - Ouda Aboumanify
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Yin Li
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Zita Aretz
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Josefin Garmshausen
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Rukeia El-Athman
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Maria Hastermann
- Center of Space Medicine Berlin, NeuroMuscular Group and Institut für Integrative Neuroanatomie, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Dieter Blottner
- Center of Space Medicine Berlin, NeuroMuscular Group and Institut für Integrative Neuroanatomie, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Angela Relógio
- Molecular Cancer Research Center (MKFZ), Medical Department of Hematology, Oncology, and Tumor Immunology, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Theoretical Biology (ITB), Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt - Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.,Institute for Systems Medicine and Bioinformatics, Department of Human Medicine, MSH Medical School Hamburg, Hamburg, Germany
| |
Collapse
|
42
|
Garcia-Bernal MI, Heredia-Rizo AM, Gonzalez-Garcia P, Cortés-Vega MD, Casuso-Holgado MJ. Validity and reliability of myotonometry for assessing muscle viscoelastic properties in patients with stroke: a systematic review and meta-analysis. Sci Rep 2021; 11:5062. [PMID: 33658623 PMCID: PMC7930253 DOI: 10.1038/s41598-021-84656-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 02/16/2021] [Indexed: 01/31/2023] Open
Abstract
There is a lack of consensus about the measurement of the muscle viscoelastic features in stroke patients. Additionally, the psychometric properties of the most-commonly used clinical tools remain controversial. Our objective is to investigate the validity and reliability of myotonometry to assess viscoelastic muscle features in stroke survivors. Pubmed, PEDro, Scopus and Cinahl were systematically searched to include studies reporting the psychometric properties of myotonometric devices used in people after stroke. The QUADAS-2 and the COSMIN checklists were used to assess the methodological quality of the studies and the psychometric properties of myotonometry. Nine studies were included in the qualitative synthesis and data from five of these were pooled in a meta-analysis. Overall, low to moderate risk of bias and applicability concerns were observed. Pooled data from intra-rater reliability for muscle tone showed a mean coefficient of correlation of 0.915 (95% CI: 0.880-0.940, I 2 = 69.2%) for upper limbs, and a mean coefficient of 0.785 (95%CI: 0.708-0.844, I 2 = 4.02%) for lower limbs. Myotonometry seems to be a valid and reliable complementary tool to assess muscle viscoelastic properties in stroke survivors, although definite conclusions about concurrent validity need further research.
Collapse
Affiliation(s)
- Maria-Isabel Garcia-Bernal
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - Alberto Marcos Heredia-Rizo
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - Paula Gonzalez-Garcia
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - María-Dolores Cortés-Vega
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| | - María Jesús Casuso-Holgado
- grid.9224.d0000 0001 2168 1229Department of Physical Therapy, Faculty of Nursing, Physiotherapy and Podiatry, University of Sevilla, Sevilla, Spain
| |
Collapse
|
43
|
Biomechanical and viscoelastic properties of the ankle muscles in men with previous history of ankle sprain. J Biomech 2020; 115:110191. [PMID: 33385869 DOI: 10.1016/j.jbiomech.2020.110191] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 11/09/2020] [Accepted: 12/11/2020] [Indexed: 12/26/2022]
Abstract
In this study, we aimed to explore the impact of previous history of lateral ankle sprain on the mechanical and viscoelastic properties of the tibialis anterior (TA), peroneus longus (PL) and gastrocnemius lateralis (GL) and medialis (GM) in asymptomatic men. For this purpose, a group of 26 men with previous history of lateral ankle sprain (ASG) and a control group (CG) of 29 healthy counter-parts participated in this study. Tone, stiffness, elasticity and mechanical stress relaxation time were measured using a myotonometer in a single session. Higher tone was noted for TA and GL in ASG as compared to CG (effect size of Cohen's d = 0.57 [p = 0.04] and 0.59 [p = 0.04], respectively). Further, stiffness was higher in ASG than in CG for TA (d = 0.56; p = 0.04), PL (d = 0.58; p = 0.04) and GL (d = 0.63; p = 0.02). Stress relaxation time was also lower for the ASG compared to the CG for TA (d = 0.61; p = 0.03), PL (d = 0.55; p = 0.04) and GL (d = 0.68; p = 0.02). There were no significant differences between groups in elasticity (p > 0.05). GM experienced no significant changes after ankle sprain in any of the variables (p > 0.05). To conclude, previous history of lateral ankle sprain results in higher TA and GL muscle tone. Likewise, these muscles in addition to PL exhibit less deformation against resistance due to their increased stiffness, thus needing a shorter time to restore to their original shape after deformation.
Collapse
|
44
|
Chang TT, Li Z, Wang XQ, Zhang ZJ. Stiffness of the Gastrocnemius-Achilles Tendon Complex Between Amateur Basketball Players and the Non-athletic General Population. Front Physiol 2020; 11:606706. [PMID: 33362580 PMCID: PMC7758317 DOI: 10.3389/fphys.2020.606706] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 11/13/2020] [Indexed: 12/28/2022] Open
Abstract
Muscle and tendon stiffness are related to sports performance, tendinopathy, and tendon degeneration. However, the effects of habitual loading on muscle and tendon mechanical properties are unclear. Using amateur basketball players as examples, we investigated the effects of mechanical loading on the stiffness of the gastrocnemius–Achilles tendon (AT) complex in non-dominant and dominant lower limbs. Then, we evaluated the correlation between gastrocnemius and AT stiffness. Forty participants (20 amateur basketball players; 20 normal non-athletic persons) were recruited for this study. Stiffness of the gastrocnemius–AT complex was assessed using MyotonPRO at neutral position and 10° dorsiflexion of the ankle joint in participants from amateur basketball players and the non-athletic general population. Our results showed a greater stiffness of the gastrocnemius–AT complex in amateur basketball players than that in healthy non-athletic subjects at neutral position and 10° dorsiflexion of the ankle joint (P < 0.05). No significant difference in stiffness was found between the non-dominant and dominant lower limbs either in amateur basketball players or in generally healthy subjects (P > 0.05). A significant positive correlation was obtained between stiffness of the AT and medial gastrocnemius (MG) in amateur basketball players (neutral position: r = 0.726 and P = 0.001; dorsiflexion 10°: r = 0.687 and P = 0.001). The amateur basketball players exhibit significantly higher stiffness value in Achilles and gastrocnemius. This is possibly caused by repeated training effects. The symmetric stiffness of the AT and gastrocnemius exists both in amateur basketball players and generally healthy subjects. A significant correlation between the AT and the MG was found in amateur basketball players.
Collapse
Affiliation(s)
- Tian-Tian Chang
- Department of Sport Rehabilitation, Shanghai University of Sport, Shanghai, China
| | - Zhe Li
- The First Clinical Medical School, Shaanxi University of Chinese Medicine, Xi'an, China
| | - Xue-Qiang Wang
- Department of Sport Rehabilitation, Shanghai University of Sport, Shanghai, China
| | - Zhi-Jie Zhang
- Rehabilitation Therapy Center, Luoyang Orthopedic Hospital of Henan Province, Orthopedic Hospital of Henan Province, Luoyang, China
| |
Collapse
|
45
|
Villanueva A, Rabal-Pelay J, Berzosa C, Gutiérrez H, Cimarras-Otal C, Lacarcel-Tejero B, Bataller-Cervero AV. Effect of a Long Exercise Program in the Reduction of Musculoskeletal Discomfort in Office Workers. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17239042. [PMID: 33291564 PMCID: PMC7729612 DOI: 10.3390/ijerph17239042] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 12/01/2020] [Indexed: 12/11/2022]
Abstract
The purpose of this study was to assess the effect of a six week exercise program to reduce the muscle tone of the trapezius and musculoskeletal discomfort (MED) of office workers. Twenty-six workers performed an exercise program based on: (1) stretching of cervical and/or dorsal region; (2) joint mobility of shoulders and rachis; (3) strengthening deep stabilizer and core muscles; and (4) scapula stabilizing exercises. A Myoton device was used to evaluate trapezius tone and the Cornell Musculoskeletal Discomfort Questionnaire was used to assess changes in MED at three points of evaluation: at the beginning (Pre_1) and at the end of the workday (Post_1), and after the training program (Pre_2). The Wilcoxon test and Cohen’s d were performed to examine differences and effect sizes between evaluations. Main results show that trapezius tone remained constant during the workday, but decreased in the dominant upper trapezius (p = 0.003, ES = −0.60) and increased in the non-dominant middle trapezius (p = 0.016, ES = 0.45) after the exercise program, which eliminated significant muscle asymmetries. MED significantly decreased in the neck (p = 0.027, ES = −0.60) and upper back (p = 0.046, ES = −0.67). In conclusion, MED appears to improve in office workers after a six week training program, which may be explained by a decrease in trapezius tone and increase in the left middle trapezius tone.
Collapse
Affiliation(s)
- Alberto Villanueva
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
| | - Juan Rabal-Pelay
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
| | - César Berzosa
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
| | - Héctor Gutiérrez
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
| | - Cristina Cimarras-Otal
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
| | | | - A. Vanessa Bataller-Cervero
- Universidad San Jorge, Campus Universitario Villanueva de Gállego, Autov. A-23 Zaragoza - Huesca, Km 299, Villanueva de Gállego, 50830 Zaragoza, Spain; (A.V.); (J.R.-P.); (C.B.); (H.G.); (C.C.-O.)
- Correspondence:
| |
Collapse
|
46
|
Sichting F, Kram NC. Phantom material testing indicates that the mechanical properties, geometrical dimensions, and tensional state of tendons affect oscillation-based measurements. Physiol Meas 2020; 41:095010. [PMID: 33021964 DOI: 10.1088/1361-6579/abb4b3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE There is an increasing interest in the application of oscillation-based measurement techniques to evaluate the mechanical stiffness of healthy and diseased tendons. These techniques measure the stiffness of a tendon indirectly by registering the oscillation response of a tendon to an external mechanical impulse. Although these measurement techniques seem to be comparatively easy and time-saving, their applicability is implicitly limited by their indirect measurement principle. APPROACH In this study, we aim to find evidence that the oscillation response of a tendon to an external mechanical impulse is not only affected by the stiffness of a tendon but also by the tendons' cross-sectional area (CSA), length, and tension. Therefore, we reviewed the current literature on oscillation-based techniques that measure in vivo tendon properties. Further, a phantom material was used to mimic the nature of tendons and to test the impact of four factors on oscillation-based measurements. MAIN RESULTS Our results indicate that the mechanical properties, geometrical dimensions (length and CSA), and tensional state affect oscillation-based measures. Surprisingly, most studies on tendon behavior often exclusively associate their oscillation-based measurements with the mechanical stiffness of a tendon. SIGNIFICANCE While this narrow perspective bears the risk of misinterpretation or false implications, a broader understanding of oscillation-based measurements has the potential to shed new light on the interaction of muscles and tendons in vivo.
Collapse
Affiliation(s)
- Freddy Sichting
- Department of Human Locomotion, Chemnitz University of Technology, Chemnitz, Germany
| | - Nicolai C Kram
- Department of Human Locomotion, Chemnitz University of Technology, Chemnitz, Germany
| |
Collapse
|
47
|
Kisilewicz A, Madeleine P, Ignasiak Z, Ciszek B, Kawczynski A, Larsen RG. Eccentric Exercise Reduces Upper Trapezius Muscle Stiffness Assessed by Shear Wave Elastography and Myotonometry. Front Bioeng Biotechnol 2020; 8:928. [PMID: 32903634 PMCID: PMC7438744 DOI: 10.3389/fbioe.2020.00928] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/20/2020] [Indexed: 12/31/2022] Open
Abstract
In this study, we tested the hypotheses that unaccustomed eccentric exercise (ECC) would reduce the elastic modulus and dynamic stiffness of the upper trapezius muscle and that these changes would correlate with increases in muscle thickness, reflecting muscle edema. Shear wave elastography was used to measure elastic modulus, dynamic stiffness was assessed using myotonometry, and muscle thickness was measured using ultrasonography. All measurements were performed at four locations over the upper trapezius before and 24 h after a single bout of ECC. Fourteen healthy participants (11 males and 3 females; 23.2 ± 3.0 years; height 175.1 ± 10.4 cm; body mass 73.8 ± 11.3 kg) took part in the study. Overall, ECC resulted in decreased elastic modulus (from 45.8 ± 1.6 to 39.4 ± 1.2 kPa, p < 0.01) and dynamic muscle stiffness (from 369.0 ± 7.3 to 302.6 ± 6.0 N/m, p < 0.01). Additionally, ECC resulted in increased muscle thickness (from 6.9 ± 0.4 to 7.3 ± 0.4 mm, p < 0.01). Spatial changes (across the four locations) were found for elastic modulus, stiffness and thickness. No significant correlations were found between changes in measures of muscle stiffness, or between changes in stiffness and changes in thickness. In conclusion, the present pilot study showed that ECC altered biomechanical muscle properties, reflected by decreased elastic modulus and dynamic muscle stiffness 24 h after ECC.
Collapse
Affiliation(s)
- Aleksandra Kisilewicz
- Department of Paralympics Sports, University School of Physical Education, Wrocław, Poland
| | - Pascal Madeleine
- Sport Sciences - Performance and Technology, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Zofia Ignasiak
- Department of Biostructure, University School of Physical Education, Wrocław, Poland
| | - Bogdan Ciszek
- Department of Descriptive and Clinical Anatomy, Medical University of Warsaw, Warsaw, Poland
| | - Adam Kawczynski
- Department of Paralympics Sports, University School of Physical Education, Wrocław, Poland
| | - Ryan Godsk Larsen
- Sport Sciences - Performance and Technology, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| |
Collapse
|
48
|
Liu CL, Zhou JP, Sun PT, Chen BZ, Zhang J, Tang CZ, Zhang ZJ. Influence of different knee and ankle ranges of motion on the elasticity of triceps surae muscles, Achilles tendon, and plantar fascia. Sci Rep 2020. [DOI: https://doi.org/10.1038/s41598-020-63730-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
AbstractStiffness is a valuable indicator of the functional capabilities of muscle-tendon-fascia. Twenty healthy subjects participated in this study in which the passive elastic properties of the medial gastrocnemius (MG), lateral gastrocnemius (LG), soleus muscles (SOL), Achilles tendon (AT, at 0 cm, 3 cm and 6 cm proximal to the calcaneus tubercle, corresponding to AT0cm, AT3cm and AT6cm, respectively) and plantar fascia (PF) were quantified when their knee was fully extended or flexed to 90° using shear wave elastography at 25° of dorsiflexion (DF25°), 0° (neutral position) of flexion, and 50° of plantar flexion (PF50°) of the ankle joint. The stiffnesses of the AT, MG, LG, SOL and the fascia with the knee fully extended were significantly higher than those with the knee flexed to 90° (p < 0.05), while the stiffness of the PF showed the opposite relationship (p < 0.05). When the knee was fully extended, the stiffness was higher in the LG than in the MG at PF50° and 0° (p < 0.01), and it was higher in the MG than in the LG at DF25° (p = 0.009). Nevertheless, regardless of the knee angle, the stiffness decreased from AT3cm > AT0cm > AT6cm at PF50° and 0° (p < 0.001), while the stiffness decreased from AT0cm > AT3cm > AT6cm at DF25°. Regardless of the knee and ankle angles, the stiffness of the PF increased in a proximal-to-distal direction (p < 0.001). These insights can be used to gain a more intuitive understanding of the relationships between the elastic properties of the muscle-tendon unit and its function.
Collapse
|
49
|
Liu CL, Zhou JP, Sun PT, Chen BZ, Zhang J, Tang CZ, Zhang ZJ. Influence of different knee and ankle ranges of motion on the elasticity of triceps surae muscles, Achilles tendon, and plantar fascia. Sci Rep 2020. [DOI: doi.org/10.1038/s41598-020-63730-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
AbstractStiffness is a valuable indicator of the functional capabilities of muscle-tendon-fascia. Twenty healthy subjects participated in this study in which the passive elastic properties of the medial gastrocnemius (MG), lateral gastrocnemius (LG), soleus muscles (SOL), Achilles tendon (AT, at 0 cm, 3 cm and 6 cm proximal to the calcaneus tubercle, corresponding to AT0cm, AT3cm and AT6cm, respectively) and plantar fascia (PF) were quantified when their knee was fully extended or flexed to 90° using shear wave elastography at 25° of dorsiflexion (DF25°), 0° (neutral position) of flexion, and 50° of plantar flexion (PF50°) of the ankle joint. The stiffnesses of the AT, MG, LG, SOL and the fascia with the knee fully extended were significantly higher than those with the knee flexed to 90° (p < 0.05), while the stiffness of the PF showed the opposite relationship (p < 0.05). When the knee was fully extended, the stiffness was higher in the LG than in the MG at PF50° and 0° (p < 0.01), and it was higher in the MG than in the LG at DF25° (p = 0.009). Nevertheless, regardless of the knee angle, the stiffness decreased from AT3cm > AT0cm > AT6cm at PF50° and 0° (p < 0.001), while the stiffness decreased from AT0cm > AT3cm > AT6cm at DF25°. Regardless of the knee and ankle angles, the stiffness of the PF increased in a proximal-to-distal direction (p < 0.001). These insights can be used to gain a more intuitive understanding of the relationships between the elastic properties of the muscle-tendon unit and its function.
Collapse
|
50
|
Liu CL, Zhou JP, Sun PT, Chen BZ, Zhang J, Tang CZ, Zhang ZJ. Influence of different knee and ankle ranges of motion on the elasticity of triceps surae muscles, Achilles tendon, and plantar fascia. Sci Rep 2020; 10:6643. [PMID: 32313166 PMCID: PMC7171074 DOI: 10.1038/s41598-020-63730-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 03/31/2020] [Indexed: 02/07/2023] Open
Abstract
Stiffness is a valuable indicator of the functional capabilities of muscle-tendon-fascia. Twenty healthy subjects participated in this study in which the passive elastic properties of the medial gastrocnemius (MG), lateral gastrocnemius (LG), soleus muscles (SOL), Achilles tendon (AT, at 0 cm, 3 cm and 6 cm proximal to the calcaneus tubercle, corresponding to AT0cm, AT3cm and AT6cm, respectively) and plantar fascia (PF) were quantified when their knee was fully extended or flexed to 90° using shear wave elastography at 25° of dorsiflexion (DF25°), 0° (neutral position) of flexion, and 50° of plantar flexion (PF50°) of the ankle joint. The stiffnesses of the AT, MG, LG, SOL and the fascia with the knee fully extended were significantly higher than those with the knee flexed to 90° (p < 0.05), while the stiffness of the PF showed the opposite relationship (p < 0.05). When the knee was fully extended, the stiffness was higher in the LG than in the MG at PF50° and 0° (p < 0.01), and it was higher in the MG than in the LG at DF25° (p = 0.009). Nevertheless, regardless of the knee angle, the stiffness decreased from AT3cm > AT0cm > AT6cm at PF50° and 0° (p < 0.001), while the stiffness decreased from AT0cm > AT3cm > AT6cm at DF25°. Regardless of the knee and ankle angles, the stiffness of the PF increased in a proximal-to-distal direction (p < 0.001). These insights can be used to gain a more intuitive understanding of the relationships between the elastic properties of the muscle-tendon unit and its function.
Collapse
Affiliation(s)
- Chun-Long Liu
- Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Ji-Ping Zhou
- Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China.,Nan'ao people's Hospital, Dapeng New District, Shenzhen, China
| | - Peng-Tao Sun
- Department of Medical Ultrasound, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Bai-Zhen Chen
- Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Jun Zhang
- Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Chun-Zhi Tang
- Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Zhi-Jie Zhang
- Luoyang Orthopedics Hospital of Henan Province, Luoyang, China.
| |
Collapse
|