Yao XH, Shen F, Hao J, Huang L, Keng B. A review of Legionella transmission risk in built environments: sources, regulations, sampling, and detection. Front Public Health 2024; 12:1415157. [PMID: 39131570 PMCID: PMC11309999 DOI: 10.3389/fpubh.2024.1415157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 07/08/2024] [Indexed: 08/13/2024] Open
Abstract
The risk of Legionella transmission in built environments remains a significant concern. Legionella can spread within buildings through aerosol transmission, prompting the exploration of airborne transmission pathways and proposing corresponding prevention and control measures based on building characteristics. To this end, a comprehensive literature review on the transmission risk of Legionella in built environments was performed. Four electronic databases (PubMed, Web of Science, Google Scholar, and CNKI) were searched from inception to March 2024 for publications reporting the risk of Legionella transmission in built environments. Relevant articles and gray literature reports were hand-searched, and 96 studies were finally included. Legionella pollution comes from various sources, mainly originates in a variety of built environments in which human beings remain for extended periods. The sources, outbreaks, national standards, regulations, and monitoring techniques for Legionella in buildings are reviewed, in addition to increases in Legionella transmission risk due to poor maintenance of water systems and long-distance transmission events caused by aerosol characteristics. Air and water sampling using various analytical methods helps identify Legionella in the environment, recognize sources in the built environments, and control outbreaks. By comparing the standard regulations of national organizations globally, the authors further highlight gaps and deficiencies in Legionella surveillance in China. Such advancements offer essential insights and references for understanding and addressing Legionella transmission risk in the built environment, with the potential to contribute to safeguarding public health and building environment safety.
Collapse
Affiliation(s)
- Xiao Hui Yao
- Department of Environmental Health, Beijing Center for Disease Prevention and Control, Beijing, China
| | - Fan Shen
- Department of Environmental Health, Beijing Center for Disease Prevention and Control, Beijing, China
| | - Jing Hao
- Department of Environmental Health, Beijing Fengtai District Center for Disease Prevention and Control, Beijing, China
| | - Lu Huang
- Department of Environmental Health, Beijing Dongcheng District Center for Disease Prevention and Control, Beijing, China
| | - Bin Keng
- Department of Environmental Health, Beijing Huairou District Center for Disease Prevention and Control, Beijing, China
| |
Collapse
|
2
|
Colautti A, Civilini M, Bortolomeazzi R, Franchi M, Felice A, De Martin S, Iacumin L. Genotypic and phenotypic profiling of 127 Legionella pneumophila strains: Insights into regional spread. PLoS One 2024; 19:e0307646. [PMID: 39028750 PMCID: PMC11259292 DOI: 10.1371/journal.pone.0307646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 07/10/2024] [Indexed: 07/21/2024] Open
Abstract
Given the recent global surge in Legionnaires' disease cases, the monitoring of Legionella pneumophila becomes increasingly crucial. Epidemiological cases often stem from local outbreaks rather than widespread dissemination, emphasizing the need to study the characteristics of this pathogen at a local level. This study focuses on isolates of L. pneumophila in the Italian region of Friuli Venezia Giulia to assess specific genotype and phenotype distribution over time and space. To this end, a total of 127 L. pneumophila strains isolated between 2005 and 2017 within national surveillance programs were analysed. Rep-PCR, RAPD, and Sau-PCR were used for genotypic characterization, while phenotypic characterization was conducted through fatty acids analysis. RAPD and Sau-PCR effectively assessed genetic characteristics, identifying different profiles for the isolates and excluding the presence of clones. Although Sau-PCR is rarely used to analyse this pathogen, it emerged as the most discriminatory technique. Phenotypically, hierarchical cluster analysis categorized strains into three groups based on varying membrane fatty acid percentages. However, both phenotypic and genotypic analyses revealed a ubiquitous profile distribution at a regional level. These results suggest an absence of correlations between strain profiles, geographical location, and isolation time, indicating instead high variability and strain dissemination within this region.
Collapse
Affiliation(s)
- Andrea Colautti
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Marcello Civilini
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Renzo Bortolomeazzi
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| | - Marinella Franchi
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Antonella Felice
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Stefano De Martin
- Laboratory of Microbiology, ARPA–Regional Agency for Environmental Protection Friuli Venezia Giulia, Udine, Italy
| | - Lucilla Iacumin
- Department of Agricultural, Food, Environmental and Animal Science (Di4A), University of Udine, Udine, Italy
| |
Collapse
|
3
|
Barbosa A, Azevedo NF, Goeres DM, Cerqueira L. Ecology of Legionella pneumophila biofilms: The link between transcriptional activity and the biphasic cycle. Biofilm 2024; 7:100196. [PMID: 38601816 PMCID: PMC11004079 DOI: 10.1016/j.bioflm.2024.100196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 03/10/2024] [Accepted: 03/29/2024] [Indexed: 04/12/2024] Open
Abstract
There has been considerable discussion regarding the environmental life cycle of Legionella pneumophila and its virulence potential in natural and man-made water systems. On the other hand, the bacterium's morphogenetic mechanisms within host cells (amoeba and macrophages) have been well documented and are linked to its ability to transition from a non-virulent, replicative state to an infectious, transmissive state. Although the morphogenetic mechanisms associated with the formation and detachment of the L. pneumophila biofilm have also been described, the capacity of the bacteria to multiply extracellularly is not generally accepted. However, several studies have shown genetic pathways within the biofilm that resemble intracellular mechanisms. Understanding the functionality of L. pneumophila cells within a biofilm is fundamental for assessing the ecology and evaluating how the biofilm architecture influences L. pneumophila survival and persistence in water systems. This manuscript provides an overview of the biphasic cycle of L. pneumophila and its implications in associated intracellular mechanisms in amoeba. It also examines the molecular pathways and gene regulation involved in L. pneumophila biofilm formation and dissemination. A holistic analysis of the transcriptional activities in L. pneumophila biofilms is provided, combining the information of intracellular mechanisms in a comprehensive outline. Furthermore, this review discusses the techniques that can be used to study the morphogenetic states of the bacteria within biofilms, at the single cell and population levels.
Collapse
Affiliation(s)
- Ana Barbosa
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Nuno F. Azevedo
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Darla M. Goeres
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- The Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | - Laura Cerqueira
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| |
Collapse
|
4
|
Ahlinder J, Eriksson KIA, Hellmér M, Salomonsson E, Granberg M, Dacklin I, Elving J, Brindefalk B. Upstream land use with microbial downstream consequences: Iron and humic substances link to Legionella spp. WATER RESEARCH 2024; 256:121579. [PMID: 38631237 DOI: 10.1016/j.watres.2024.121579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 03/28/2024] [Accepted: 04/05/2024] [Indexed: 04/19/2024]
Abstract
Intensified land use can disturb water quality, potentially increasing the abundance of bacterial pathogens, threatening public access to clean water. This threat involves both direct contamination of faecal bacteria as well as indirect factors, such as disturbed water chemistry and microbiota, which can lead to contamination. While direct contamination has been well described, the impact of indirect factors is less explored, despite the potential of severe downstream consequences on water supply. To assess direct and indirect downstream effects of buildings, farms, pastures and fields on potential water sources, we studied five Swedish lakes and their inflows. We analysed a total of 160 samples in a gradient of anthropogenic activity spanning four time points, including faecal and water-quality indicators. Through species distribution modelling, Random Forest and network analysis using 16S rRNA amplicon sequencing data, our findings highlight that land use indirectly impacts lakes via inflows. Land use impacted approximately one third of inflow microbiota taxa, in turn impacting ∼20-50 % of lake taxa. Indirect effects via inflows were also suggested by causal links between e.g. water colour and lake bacterial taxa, where this influenced the abundance of several freshwater bacteria, such as Polynucleobacter and Limnohabitans. However, it was not possible to identify direct effects on the lakes based on analysis of physiochemical- or microbial parameters. To avoid potential downstream consequences on water supply, it is thus important to consider possible indirect effects from upstream land use and inflows, even when no direct effects can be observed on lakes. Legionella (a genus containing bacterial pathogens) illustrated potential consequences, since the genus was particularly abundant in inflows and was shown to increase by the presence of pastures, fields, and farms. The approach presented here could be used to assess the suitability of lakes as alternative raw water sources or help to mitigate contaminations in important water catchments. Continued broad investigations of stressors on the microbial network can identify indirect effects, avoid enrichment of pathogens, and help secure water accessibility.
Collapse
Affiliation(s)
- Jon Ahlinder
- Division of CBRN Defence and Security, Swedish Defence Research Agency (FOI), Sweden; Department of Tree Breeding, Skogforsk, Sävar, SE-91821, Sweden
| | - Karolina Ida Anna Eriksson
- Department of Ecology and Environmental Sciences, Faculty of Science and Technology, Umeå University, Sweden; Umeå Marine Sciences Centre, Umeå University, Hörnefors, 905 71, Sweden.
| | - Maria Hellmér
- Department of Biology, Science Division, Swedish Food Agency, Sweden
| | - Emelie Salomonsson
- Division of CBRN Defence and Security, Swedish Defence Research Agency (FOI), Sweden
| | - Malin Granberg
- Division of CBRN Defence and Security, Swedish Defence Research Agency (FOI), Sweden
| | - Ingrid Dacklin
- Division of CBRN Defence and Security, Swedish Defence Research Agency (FOI), Sweden
| | - Josefine Elving
- Department of Chemistry, Environment and Feed Hygiene, Swedish Veterinary Agency, Sweden
| | - Björn Brindefalk
- Division of CBRN Defence and Security, Swedish Defence Research Agency (FOI), Sweden; Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Sweden
| |
Collapse
|
5
|
Pijnacker R, Brandsema P, Euser S, Vahidnia A, Kuiter A, Limaheluw J, Schout C, Haj Mohammad G, Raven S. An outbreak of Legionnaires' disease linked to a municipal and industrial wastewater treatment plant, The Netherlands, September-October 2022. Euro Surveill 2024; 29:2300506. [PMID: 38757288 PMCID: PMC11100293 DOI: 10.2807/1560-7917.es.2024.29.20.2300506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 02/19/2024] [Indexed: 05/18/2024] Open
Abstract
Wastewater treatment plants (WWTPs) are increasingly identified as Legionnaires' disease (LD) sources. An outbreak investigation was initiated following five LD cases reported in September 2022 in Houten, the Netherlands. Case identification was based on the European LD case definition, with symptom onset from 1 September 2022, residence in or within 5 km of Houten, or visit to Houten within the incubation period, without other likely sources. We sampled potential sources and genotyped environmental and clinical isolates. We identified 15 LD cases with onset between 13 September and 23 October 2022. A spatial source identification and wind direction model suggested an industrial (iWWTP) and a municipal WWTP (mWWTP) as potential sources, with the first discharging water into the latter. Both tested positive for Legionella pneumophila serogroups 1 and 6 with multiple sequence types (ST). We detected L. pneumophila sg1 ST42 in the mWWTP, matching with one of three available clinical isolates. Following control measures at the WWTPs, no further cases were observed. This outbreak underlines that municipal and industrial WWTPs can play an important role in community LD cases and outbreaks, especially those with favourable conditions for Legionella growth and dissemination, or even non-favourable conditions for growth but with the influx of contaminated water.
Collapse
Affiliation(s)
- Roan Pijnacker
- Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, the Netherlands
- Department of Infectious Diseases, Public Health Service region Utrecht (GGD), Zeist, the Netherlands
| | - Petra Brandsema
- Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, the Netherlands
| | - Sjoerd Euser
- Regional Public Health Laboratory Kennemerland, Haarlem, the Netherlands
| | - Ali Vahidnia
- Regional Public Health Laboratory Kennemerland, Haarlem, the Netherlands
| | - Arnold Kuiter
- Environmental Services Regarding Authorization and Enforcement (RUD Utrecht), Utrecht, the Netherlands
| | - Jesse Limaheluw
- Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, the Netherlands
| | - Christine Schout
- Department of Infectious Diseases, Public Health Service region Utrecht (GGD), Zeist, the Netherlands
| | - Gaaled Haj Mohammad
- Department of Infectious Diseases, Public Health Service region Utrecht (GGD), Zeist, the Netherlands
| | - Stijn Raven
- Department of Infectious Diseases, Public Health Service region Utrecht (GGD), Zeist, the Netherlands
| |
Collapse
|
6
|
LeChevallier MW, Prosser T, Stevens M. Opportunistic Pathogens in Drinking Water Distribution Systems-A Review. Microorganisms 2024; 12:916. [PMID: 38792751 PMCID: PMC11124194 DOI: 10.3390/microorganisms12050916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024] Open
Abstract
In contrast to "frank" pathogens, like Salmonella entrocolitica, Shigella dysenteriae, and Vibrio cholerae, that always have a probability of disease, "opportunistic" pathogens are organisms that cause an infectious disease in a host with a weakened immune system and rarely in a healthy host. Historically, drinking water treatment has focused on control of frank pathogens, particularly those from human or animal sources (like Giardia lamblia, Cryptosporidium parvum, or Hepatitis A virus), but in recent years outbreaks from drinking water have increasingly been due to opportunistic pathogens. Characteristics of opportunistic pathogens that make them problematic for water treatment include: (1) they are normally present in aquatic environments, (2) they grow in biofilms that protect the bacteria from disinfectants, and (3) under appropriate conditions in drinking water systems (e.g., warm water, stagnation, low disinfectant levels, etc.), these bacteria can amplify to levels that can pose a public health risk. The three most common opportunistic pathogens in drinking water systems are Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. This report focuses on these organisms to provide information on their public health risk, occurrence in drinking water systems, susceptibility to various disinfectants, and other operational practices (like flushing and cleaning of pipes and storage tanks). In addition, information is provided on a group of nine other opportunistic pathogens that are less commonly found in drinking water systems, including Aeromonas hydrophila, Klebsiella pneumoniae, Serratia marcescens, Burkholderia pseudomallei, Acinetobacter baumannii, Stenotrophomonas maltophilia, Arcobacter butzleri, and several free-living amoebae including Naegleria fowleri and species of Acanthamoeba. The public health risk for these microbes in drinking water is still unclear, but in most cases, efforts to manage Legionella, mycobacteria, and Pseudomonas risks will also be effective for these other opportunistic pathogens. The approach to managing opportunistic pathogens in drinking water supplies focuses on controlling the growth of these organisms. Many of these microbes are normal inhabitants in biofilms in water, so the attention is less on eliminating these organisms from entering the system and more on managing their occurrence and concentrations in the pipe network. With anticipated warming trends associated with climate change, the factors that drive the growth of opportunistic pathogens in drinking water systems will likely increase. It is important, therefore, to evaluate treatment barriers and management activities for control of opportunistic pathogen risks. Controls for primary treatment, particularly for turbidity management and disinfection, should be reviewed to ensure adequacy for opportunistic pathogen control. However, the major focus for the utility's opportunistic pathogen risk reduction plan is the management of biological activity and biofilms in the distribution system. Factors that influence the growth of microbes (primarily in biofilms) in the distribution system include, temperature, disinfectant type and concentration, nutrient levels (measured as AOC or BDOC), stagnation, flushing of pipes and cleaning of storage tank sediments, and corrosion control. Pressure management and distribution system integrity are also important to the microbial quality of water but are related more to the intrusion of contaminants into the distribution system rather than directly related to microbial growth. Summarizing the identified risk from drinking water, the availability and quality of disinfection data for treatment, and guidelines or standards for control showed that adequate information is best available for management of L. pneumophila. For L. pneumophila, the risk for this organism has been clearly established from drinking water, cases have increased worldwide, and it is one of the most identified causes of drinking water outbreaks. Water management best practices (e.g., maintenance of a disinfectant residual throughout the distribution system, flushing and cleaning of sediments in pipelines and storage tanks, among others) have been shown to be effective for control of L. pneumophila in water supplies. In addition, there are well documented management guidelines available for the control of the organism in drinking water distribution systems. By comparison, management of risks for Mycobacteria from water are less clear than for L. pneumophila. Treatment of M. avium is difficult due to its resistance to disinfection, the tendency to form clumps, and attachment to surfaces in biofilms. Additionally, there are no guidelines for management of M. avium in drinking water, and one risk assessment study suggested a low risk of infection. The role of tap water in the transmission of the other opportunistic pathogens is less clear and, in many cases, actions to manage L. pneumophila (e.g., maintenance of a disinfectant residual, flushing, cleaning of storage tanks, etc.) will also be beneficial in helping to manage these organisms as well.
Collapse
Affiliation(s)
| | - Toby Prosser
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| | - Melita Stevens
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| |
Collapse
|
7
|
Clements E, Crank K, Nerenberg R, Atkinson A, Gerrity D, Hannoun D. Quantitative Microbial Risk Assessment Framework Incorporating Water Ages with Legionella pneumophila Growth Rates. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6540-6551. [PMID: 38574283 PMCID: PMC11025131 DOI: 10.1021/acs.est.4c01208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/20/2024] [Accepted: 03/21/2024] [Indexed: 04/06/2024]
Abstract
Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.
Collapse
Affiliation(s)
- Emily Clements
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Katherine Crank
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Robert Nerenberg
- Department
of Civil & Environmental Engineering & Earth Science, University of Notre Dame, 156 Fitzpatrick Hall, Notre
Dame, Indiana 46556, United States
| | - Ariel Atkinson
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Daniel Gerrity
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| | - Deena Hannoun
- Southern
Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States
| |
Collapse
|
8
|
Heilmann A, Rueda Z, Alexander D, Laupland KB, Keynan Y. Impact of climate change on amoeba and the bacteria they host. JOURNAL OF THE ASSOCIATION OF MEDICAL MICROBIOLOGY AND INFECTIOUS DISEASE CANADA = JOURNAL OFFICIEL DE L'ASSOCIATION POUR LA MICROBIOLOGIE MEDICALE ET L'INFECTIOLOGIE CANADA 2024; 9:1-5. [PMID: 38567368 PMCID: PMC10984314 DOI: 10.3138/jammi-2023-09-08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Affiliation(s)
- Ashley Heilmann
- Department of Medical Microbiology and Infectious Diseases, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Zulma Rueda
- Department of Medical Microbiology and Infectious Diseases, University of Manitoba, Winnipeg, Manitoba, Canada
| | - David Alexander
- Department of Medical Microbiology and Infectious Diseases, University of Manitoba, Winnipeg, Manitoba, Canada
- Cadham Provincial Lab, Winnipeg, Manitoba, Canada
| | - Kevin B Laupland
- Department of Intensive Care Services, Royal Brisbane and Women’s Hospital, Butterfield Street, Brisbane, Queensland, Australia
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology (QUT), Brisbane, Australia
| | - Yoav Keynan
- Department of Medical Microbiology and Infectious Diseases, University of Manitoba, Winnipeg, Manitoba, Canada
- Department of Internal Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
- Department of Community Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| |
Collapse
|
9
|
Crépin A, Thiroux A, Alafaci A, Boukerb AM, Dufour I, Chrysanthou E, Bertaux J, Tahrioui A, Bazire A, Rodrigues S, Taupin L, Feuilloley M, Dufour A, Caillon J, Lesouhaitier O, Chevalier S, Berjeaud JM, Verdon J. Sensitivity of Legionella pneumophila to phthalates and their substitutes. Sci Rep 2023; 13:22145. [PMID: 38092873 PMCID: PMC10719263 DOI: 10.1038/s41598-023-49426-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 12/07/2023] [Indexed: 12/17/2023] Open
Abstract
Phthalates constitute a family of anthropogenic chemicals developed to be used in the manufacture of plastics, solvents, and personal care products. Their dispersion and accumulation in many environments can occur at all stages of their use (from synthesis to recycling). However, many phthalates together with other accumulated engineered chemicals have been shown to interfere with hormone activities. These compounds are also in close contact with microorganisms that are free-living, in biofilms or in microbiota, within multicellular organisms. Herein, the activity of several phthalates and their substitutes were investigated on the opportunistic pathogen Legionella pneumophila, an aquatic microbe that can infect humans. Beside showing the toxicity of some phthalates, data suggested that Acetyl tributyl citrate (ATBC) and DBP (Di-n-butyl phthalate) at environmental doses (i.e. 10-6 M and 10-8 M) can modulate Legionella behavior in terms of motility, biofilm formation and response to antibiotics. A dose of 10-6 M mostly induced adverse effects for the bacteria, in contrast to a dose of 10-8 M. No perturbation of virulence towards Acanthamoeba castellanii was recorded. These behavioral alterations suggest that L. pneumophila is able to sense ATBC and DBP, in a cross-talk that either mimics the response to a native ligand, or dysregulates its physiology.
Collapse
Affiliation(s)
- Alexandre Crépin
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Audrey Thiroux
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Aurélien Alafaci
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Amine M Boukerb
- Unité de recherche Communication Bactérienne et Stratégies Anti-infectieuses, UR4312, Université de Rouen Normandie, Normandie Université, Évreux, France
| | - Izelenn Dufour
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Eirini Chrysanthou
- Department of Life Sciences and Systems Biology, University of Turin, 10100, Turin, Italy
- Cancer Genomics Lab, Fondazione Edo ed Elvo Tempia, 13900, Biella, Italy
| | - Joanne Bertaux
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Ali Tahrioui
- Unité de recherche Communication Bactérienne et Stratégies Anti-infectieuses, UR4312, Université de Rouen Normandie, Normandie Université, Évreux, France
| | - Alexis Bazire
- Laboratoire de Biotechnologie et Chimie Marines, Université Bretagne Sud, EMR CNRS 6076, IUEM, Lorient, France
| | - Sophie Rodrigues
- Laboratoire de Biotechnologie et Chimie Marines, Université Bretagne Sud, EMR CNRS 6076, IUEM, Lorient, France
| | - Laure Taupin
- Laboratoire de Biotechnologie et Chimie Marines, Université Bretagne Sud, EMR CNRS 6076, IUEM, Lorient, France
| | - Marc Feuilloley
- Unité de recherche Communication Bactérienne et Stratégies Anti-infectieuses, UR4312, Université de Rouen Normandie, Normandie Université, Évreux, France
| | - Alain Dufour
- Laboratoire de Biotechnologie et Chimie Marines, Université Bretagne Sud, EMR CNRS 6076, IUEM, Lorient, France
| | - Jocelyne Caillon
- Faculté de Médecine, EA3826 Thérapeutiques Cliniques et Expérimentales des Infections, Université de Nantes, Nantes, France
| | - Olivier Lesouhaitier
- Unité de recherche Communication Bactérienne et Stratégies Anti-infectieuses, UR4312, Université de Rouen Normandie, Normandie Université, Évreux, France
| | - Sylvie Chevalier
- Unité de recherche Communication Bactérienne et Stratégies Anti-infectieuses, UR4312, Université de Rouen Normandie, Normandie Université, Évreux, France
| | - Jean-Marc Berjeaud
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France
| | - Julien Verdon
- Laboratoire Ecologie and Biologie des Interactions, UMR CNRS 7267, Université de Poitiers, 1 Rue Georges Bonnet, TSA 51106, 86073, Poitiers Cedex 9, France.
| |
Collapse
|
10
|
Grabowska-Grucza K, Kiersztyn B. Relationships between Legionella and Aeromonas spp. and associated lake bacterial communities across seasonal changes in an anthropogenic eutrophication gradient. Sci Rep 2023; 13:17076. [PMID: 37816753 PMCID: PMC10564844 DOI: 10.1038/s41598-023-43234-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 09/21/2023] [Indexed: 10/12/2023] Open
Abstract
Anthropogenic eutrophication of lakes threatens their homeostasis and carries an increased risk of development of potentially pathogenic microorganisms. In this paper we show how eutrophication affects seasonal changes in the taxonomic structure of bacterioplankton and whether these changes are associated with the relative abundance of pathogenic bacteria of the genera Legionella and Aeromonas. The subject of the study was a unique system of interconnected lakes in northern Poland (Great Masurian Lakes system), characterized by the presence of eutrophic gradient. We found that the taxonomic structure of the bacterial community in eutrophic lakes was significantly season dependent. No such significant seasonal changes were observed in meso-eutrophic lakes. We found that there is a specific taxonomic composition of bacteria associated with the occurrence of Legionella spp. The highest positive significant correlations were found for families Pirellulaceae, Mycobacteriaceae and Gemmataceae. The highest negative correlations were found for the families Sporichthyaceae, Flavobacteriaceae, the uncultured families of class Verrucomicrobia and Chitinophagaceae. We used also an Automatic Neural Network model to estimate the relative abundance of Legionella spp. based on the relative abundance of dominant bacterial families. In the case of Aeromonas spp. we did not find a clear relationship with bacterial communities inhabiting lakes of different trophic state. Our research has shown that anthropogenic eutrophication causes significant changes in the taxonomic composition of lake bacteria and contributes to an increase in the proportion of potentially pathogenic Legionella spp.
Collapse
Affiliation(s)
- Karolina Grabowska-Grucza
- Institute of Functional Biology and Ecology, Faculty of Biology, University of Warsaw, Żwirki i Wigury 101, 02-089, Warszawa, Poland.
| | - Bartosz Kiersztyn
- Institute of Functional Biology and Ecology, Faculty of Biology, University of Warsaw, Żwirki i Wigury 101, 02-089, Warszawa, Poland
| |
Collapse
|
11
|
Bertolino G, Marras L, Coroneo V. The Detection Limits of Legionella According to the EU Directive 2020/2184. Could That Be Too Permissive? ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023. [PMID: 37777698 DOI: 10.1007/5584_2023_790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/02/2023]
Abstract
INTRODUCTION The problem of detecting legionella after a case of legionellosis from the source of environmental contamination has been known since a long time ago. Legionella is a bacterium present in various natural and artificial habitats and especially in surface fresh waters. It is found in greater concentration in warm waters, at temperatures between 20 °C and 42 °C. The greatest risk factor for humans is represented by the presence of Legionella in water distribution systems in hospitals, medical equipment (e.g. respirators, dialyzers, inhalers, humidifiers, water, massage equipment used in balneotherapy) and turbines used in dental practices, especially for hospitalized individuals. In the EU directive 2020/2184, issued by the European parliament on 16/12/2020, the concentration of Legionella was added to the parameters to be determined in assessing the quality of drinking water intended for human consumption. The objectives were to improve the quality standard of drinking water, reduce the consumption of bottled water and consequently reduce plastic waste. The WHO notes that Legionella causes the greatest burden from a health point of view and it is included among the parameters that require careful monitoring with a limit of less than 1000 CFU/L. The aim of this report was to evaluate the new EU directive 2020/2184 on the light of our laboratory experience. MATERIALS AND METHODS A total of 459 samples were processed at our Hygiene of food Laboratory - Department of Medical Sciences and Public Health. All statistical analyses were conducted using the SPSS statistical package (version 23 for Windows. SPSS, Inc. Chicago, Ill). RESULTS AND DISCUSSION Of the 67 structures examined where the cases occurred, 35 showed samples with at least one over-threshold value considering the reference value of 100 CFU/L, whereas using the new limit of 1000 CFU/L, only 25 structures resulted as having at least one sample above the threshold. In our experience as a regional reference laboratory for Legionella research, the increase from 100 CFU/L to 1,000 CFU/L could lead to a lower alert level. In fact, in the period between October 2017 and October 2021, the median value of CFU/L in presence of a case was 0 (0-100). Despite the large amount of studies on Legionella only a few relate the withdrawals and the consequent CFU/L with the confirmed cases of legionellosis, as in our analysis. The 75° percentile values of the Legionella concentration equal to 100 CFU/L in all samples associated with cases and clusters leads us to hypothesize that the limit equal to 1000 CFU/L that will be introduced for environmental monitoring as per recent European regulations may not be sufficiently protective for minimizing risk in the population, especially in healthcare facilities where fragile patients are assisted.
Collapse
Affiliation(s)
- G Bertolino
- Department of Pharmacy, Azienda Ospedaliero-Universitaria di Cagliari, Cagliari, Italy
| | - L Marras
- Department of Pharmacy, Azienda Ospedaliero-Universitaria di Cagliari, Cagliari, Italy
- Clinical Laboratory, Cagliari, Italy
| | - V Coroneo
- Department of Pharmacy, Azienda Ospedaliero-Universitaria di Cagliari, Cagliari, Italy
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italia
| |
Collapse
|
12
|
Ayesha A, Chow FWN, Leung PHM. Role of Legionella pneumophila outer membrane vesicles in host-pathogen interaction. Front Microbiol 2023; 14:1270123. [PMID: 37817751 PMCID: PMC10561282 DOI: 10.3389/fmicb.2023.1270123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 09/11/2023] [Indexed: 10/12/2023] Open
Abstract
Legionella pneumophila is an opportunistic intracellular pathogen that inhabits artificial water systems and can be transmitted to human hosts by contaminated aerosols. Upon inhalation, it colonizes and grows inside the alveolar macrophages and causes Legionnaires' disease. To effectively control and manage Legionnaires' disease, a deep understanding of the host-pathogen interaction is crucial. Bacterial extracellular vesicles, particularly outer membrane vesicles (OMVs) have emerged as mediators of intercellular communication between bacteria and host cells. These OMVs carry a diverse cargo, including proteins, toxins, virulence factors, and nucleic acids. OMVs play a pivotal role in disease pathogenesis by helping bacteria in colonization, delivering virulence factors into host cells, and modulating host immune responses. This review highlights the role of OMVs in the context of host-pathogen interaction shedding light on the pathogenesis of L. pneumophila. Understanding the functions of OMVs and their cargo provides valuable insights into potential therapeutic targets and interventions for combating Legionnaires' disease.
Collapse
Affiliation(s)
| | | | - Polly Hang-Mei Leung
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China
| |
Collapse
|
13
|
Riccò M, Ferraro P, Ranzieri S, Boldini G, Zanella I, Marchesi F. Legionnaires' Disease in Occupational Settings: A Cross-Sectional Study from Northeastern Italy (2019). Trop Med Infect Dis 2023; 8:364. [PMID: 37505660 PMCID: PMC10384770 DOI: 10.3390/tropicalmed8070364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 07/09/2023] [Accepted: 07/15/2023] [Indexed: 07/29/2023] Open
Abstract
In Italy, Legionnaires' Disease (LD) causes >1000 hospital admissions per year, with a lethality rate of 5 to 10%. Occupational exposures could reasonably explain a substantial share of total cases, but the role of Occupational Physicians (OPs) in management and prevention of LD has been scarcely investigated. The present survey therefore evaluates the knowledge, attitudes and practices (KAP) regarding LD from a convenience sample of Italian OPs, focusing on their participation in preventive interventions. A total of 165 OPs were recruited through a training event (Parma, Northeastern Italy, 2019), and completed a specifically designed structured questionnaire. The association between reported participation in preventive interventions and individual factors was analyzed using a binary logistic regression model, calculating corresponding multivariable Odds Ratio (aOR). Overall, participants exhibited satisfactory knowledge of the clinical and diagnostic aspects of LD, while substantial uncertainties were associated epidemiological factors (i.e., notification rate and lethality). Although the majority of participating OPs reportedly assisted at least one hospital (26.7%) and/or a nursing home (42.4%) and/or a wastewater treatment plant, only 41.8% reportedly contributed to the risk assessment for LD and 18.8% promoted specifically designed preventive measures. Working as OPs in nursing homes (aOR 8.732; 95% Confidence Intervals [95%CI] 2.991 to 25.487) and wastewater treatment plants (aOR 8.710; 95%CI 2.844 to 26.668) was associated with participation in the risk assessment for LD, while the promotion of preventive practice was associated with working as an OP in hospitals (aOR 6.792; 95%CI 2.026 to 22.764) and wastewater treatment plants (aOR 4.464, 95%CI 1.363 to 14.619). In other words, the effective participation of the OP in the implementation of preventive measures appears uncommon and is limited to certain occupational settings. Collectively, these results highlight the importance of tailoring specifically designed information campaigns aimed to raise the involvement of OPs in the prevention of LD in occupational settings other than healthcare.
Collapse
Affiliation(s)
- Matteo Riccò
- Servizio di Prevenzione e Sicurezza Negli Ambienti di Lavoro (SPSAL), AUSL-IRCCS di Reggio Emilia, Via Amendola n.2, I-42122 Reggio Emilia, Italy
| | - Pietro Ferraro
- Occupational Medicine Unit, Direzione Sanità, Italian Railways' Infrastructure Division, RFI SpA, I-00161 Rome, Italy
| | - Silvia Ranzieri
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| | - Giorgia Boldini
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
- Servizio di Igiene Pubblica, AUSL di Parma, Via Vasari n.13/a, I-43123 Parma, Italy
| | - Ilaria Zanella
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| | - Federico Marchesi
- Department of Medicine and Surgery, University of Parma, Via Gramsci, 14, I-43126 Parma, Italy
| |
Collapse
|
14
|
Radziminski C, White P. Cooling tower Legionella pneumophila surveillance results: Vancouver, Canada, 2021. JOURNAL OF WATER AND HEALTH 2023; 21:313-328. [PMID: 37338312 PMCID: wh_2023_154 DOI: 10.2166/wh.2023.154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/21/2023]
Abstract
Cooling towers have been linked to Legionnaires' disease cases and outbreaks. Legionella pneumophila results (from a culture-based method) are presented for 557 cooling towers across the City of Vancouver, Canada for 2021. Results of 10 CFU/mL or greater (defined as exceedances) were reported for 30 cooling towers (5.4%), including six >1,000 CFU/mL, and L. pneumophila serogroup 1 (sg1) was identified in 17 of these cooling towers (out of 28 with serogroup-level analysis). The data indicate highly localised Legionella issues, with exceedances concentrated within 16 facilities, including two hospitals. In the 3 months preceding each cooling tower exceedance, the nearest municipal water sampling station had a free chlorine residual of at least 0.46 mg/L and a temperature of <20 °C. There was not a statistically significant correlation between the L. pneumophila concentration of a cooling tower in exceedance and the municipal water free chlorine residual, temperature, pH, turbidity or conductivity. There was a statistically significant negative correlation between the concentrations of L. pneumophila sg1 and other L. pneumophila serogroups in cooling towers. This unique dataset underscores the pivotal role of building owners and managers in preventing the growth of Legionella bacteria and the value of regulations to verify operations and maintenance practices.
Collapse
Affiliation(s)
- Christopher Radziminski
- City of Vancouver, Development, Buildings & Licensing, 515 W 10th Avenue, Vancouver, BC V5Z 4A8, Canada E-mail:
| | - Phillip White
- City of Vancouver, Development, Buildings & Licensing, 515 W 10th Avenue, Vancouver, BC V5Z 4A8, Canada E-mail:
| |
Collapse
|
15
|
Legionella pneumonia as a rising public health threat in Argentina: Is it the time to worry? Ann Med Surg (Lond) 2022; 83:104801. [PMID: 36345419 PMCID: PMC9636435 DOI: 10.1016/j.amsu.2022.104801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 10/23/2022] [Indexed: 11/11/2022] Open
|
16
|
Iliadi V, Staykova J, Iliadis S, Konstantinidou I, Sivykh P, Romanidou G, Vardikov DF, Cassimos D, Konstantinidis TG. Legionella pneumophila: The Journey from the Environment to the Blood. J Clin Med 2022; 11:jcm11206126. [PMID: 36294446 PMCID: PMC9605555 DOI: 10.3390/jcm11206126] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/26/2022] [Accepted: 10/16/2022] [Indexed: 11/16/2022] Open
Abstract
An outbreak of a potentially fatal form of pneumonia in 1976 and in the annual convention of the American Legion was the first time that Legionella spp. was identified. Thereafter, the term Legionnaires’ disease (LD) was established. The infection in humans is transmitted by the inhalation of aerosols that contain the microorganisms that belong to the Legionellaceae family and the genus Legionella. The genus Legionella contains genetically heterogeneous species and serogroups. The Legionella pneumophila serogroup 1 (Lp1) is the most often detected strain in outbreaks of LD. The pathogenesis of LD infection initiates with the attachment of the bacterial cells to the host cells, and subsequent intracellular replication. Following invasion, Legionella spp. activates its virulence mechanisms: generation of specific compartments of Legionella-containing vacuole (LCV), and expression of genes that encode a type IV secretion system (T4SS) for the translocation of proteins. The ability of L. pneumophila to transmigrate across the lung’s epithelium barrier leads to bacteremia, spread, and invasion of many organs with subsequent manifestations, complications, and septic shock. The clinical manifestations of LD depend on the bacterial load in the aerosol, the virulence factors, and the immune status of the patient. The infection has two distinct forms: the non- pneumatic form or Pontiac fever, which is a milder febrile flu-like illness, and LD, a more severe form, which includes pneumonia. In addition, the extrapulmonary involvement of LD can include heart, brain, abdomen, and joints.
Collapse
Affiliation(s)
- Valeria Iliadi
- Izhevsk State Medical Academy, Kommunarov Street 281, 426034 Izhevsk, Russia
| | - Jeni Staykova
- Faculty of Public Health, Medical University of Sofia, Byalo More Str. 8, 1527 Sofia, Bulgaria
| | - Sergios Iliadis
- Izhevsk State Medical Academy, Kommunarov Street 281, 426034 Izhevsk, Russia
| | | | - Polina Sivykh
- State Budgetary Health City Polyclinic No 2 (GBUZ GB2) of Krasnodar, Seleznev Street 4/10, 350059 Krasnodar, Russia
| | - Gioulia Romanidou
- Nephrology Department, General Hospital “Sismanogleio”, 69100 Komotini, Greece
| | - Daniil F. Vardikov
- Russian Research Center for Radiology and Surgical Technologies of the Ministry of Health of the Russian Federation, Tkachey Str. 70-16, 192029 St. Petersburg, Russia
| | - Dimitrios Cassimos
- Pediatric Department, Democritus University of Thrace, 68100 Alexandroupolis, Greece
| | - Theocharis G. Konstantinidis
- Blood Transfusion Center, University General Hospital of Alexandroupolis Dragana Campus, 68100 Alexandroupolis, Greece
- Correspondence: ; Tel.: +30-2551-352005
| |
Collapse
|
17
|
Chawich J, Hassen WM, Singh A, Marquez DT, DeRosa MC, Dubowski JJ. Polymer Brushes on GaAs and GaAs/AlGaAs Nanoheterostructures: A Promising Platform for Attractive Detection of Legionella pneumophila. ACS OMEGA 2022; 7:33349-33357. [PMID: 36157789 PMCID: PMC9494436 DOI: 10.1021/acsomega.2c03959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 08/23/2022] [Indexed: 06/16/2023]
Abstract
This work reports on the potential of polymer brushes (PBs) grown on GaAs substrates (PB-GaAs) as a promising platform for the detection of Legionella pneumophila (Lp). Three functionalization approaches of the GaAs surface were used, and their compatibility with antibodies against Lp was evaluated using Fourier transform infrared spectroscopy and fluorescence microscopy. The incorporation of PBs on GaAs has allowed a significant improvement of the antibody immobilization by increased surface coverage. Bacterial capture experiments demonstrated the promising potential for enhanced immobilization of Lp in comparison with the conventional alkanethiol self-assembled monolayer-based biosensing architectures. Consistent with an eightfold improved capture of bacteria on the surface of a PB-functionalized GaAs/AlGaAs digital photocorrosion biosensor, we report the attractive detection of Lp at 500 CFU/mL.
Collapse
Affiliation(s)
- Juliana Chawich
- Interdisciplinary
Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, Québec J1K 0A5, Canada
| | - Walid M. Hassen
- Interdisciplinary
Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, Québec J1K 0A5, Canada
| | - Amanpreet Singh
- Interdisciplinary
Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, Québec J1K 0A5, Canada
| | - Daniela T. Marquez
- Interdisciplinary
Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, Québec J1K 0A5, Canada
- Department
of Chemistry, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Maria C. DeRosa
- Department
of Chemistry, Carleton University, Ottawa, Ontario K1S 5B6, Canada
| | - Jan J. Dubowski
- Interdisciplinary
Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, Québec J1K 0A5, Canada
| |
Collapse
|
18
|
Johnston JD, Cowger AE, Weber KS. Bioaerosol and microbial exposures from residential evaporative coolers and their potential health outcomes: A review. INDOOR AIR 2022; 32:e13082. [PMID: 36168234 PMCID: PMC9826010 DOI: 10.1111/ina.13082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 06/10/2022] [Accepted: 07/08/2022] [Indexed: 06/16/2023]
Abstract
Evaporative cooling is an energy efficient form of air conditioning in dry climates that functions by pulling hot, dry outdoor air across a wet evaporative pad. While evaporative coolers can help save energy, they also have the potential to influence human health. Studies have shown residential evaporative coolers may pull outdoor air pollutants into the home or contribute to elevated levels of indoor bioaerosols that may be harmful to health. There is also evidence that evaporative coolers can enable a diverse microbial environment that may confer early-life immunological protection against the development of allergies and asthma or exacerbate these same hypersensitivities. This review summarizes the current knowledge of bioaerosol and microbiological studies associated with evaporative coolers, focusing on harmful and potentially helpful outcomes from their use. We evaluate the effects of evaporative coolers on indoor bacterial endotoxins, fungal β-(1 → 3)-D-glucans, dust mite antigens, residential microbial communities, and Legionella pneumophila. To our knowledge, this is the first review to summarize and evaluate studies on the influence that evaporative coolers have on the bioaerosol and microbiological profile of homes. This brings to light a gap in the literature on evaporative coolers, which is the lack of data on health effects associated with their use.
Collapse
Affiliation(s)
| | | | - K. Scott Weber
- Department of Microbiology & Molecular BiologyBrigham Young UniversityProvoUtahUSA
| |
Collapse
|
19
|
Nácher-Vázquez M, Barbosa A, Armelim I, Azevedo AS, Almeida GN, Pizarro C, Azevedo NF, Almeida C, Cerqueira L. Development of a Novel Peptide Nucleic Acid Probe for the Detection of Legionella spp. in Water Samples. Microorganisms 2022; 10:1409. [PMID: 35889127 PMCID: PMC9318766 DOI: 10.3390/microorganisms10071409] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/13/2022] [Accepted: 06/14/2022] [Indexed: 02/04/2023] Open
Abstract
Legionella are opportunistic intracellular pathogens that are found throughout the environment. The Legionella contamination of water systems represents a serious social problem that can lead to severe diseases, which can manifest as both Pontiac fever and Legionnaires' disease (LD) infections. Fluorescence in situ hybridization using nucleic acid mimic probes (NAM-FISH) is a powerful and versatile technique for bacterial detection. By optimizing a peptide nucleic acid (PNA) sequence based on fluorescently selective binding to specific bacterial rRNA sequences, we established a new PNA-FISH method that has been successfully designed for the specific detection of the genus Legionella. The LEG22 PNA probe has shown great theoretical performance, presenting 99.9% specificity and 96.9% sensitivity. We also demonstrated that the PNA-FISH approach presents a good signal-to-noise ratio when applied in artificially contaminated water samples directly on filtration membranes or after cells elution. For water samples with higher turbidity (from cooling tower water systems), there is still the need for further method optimization in order to detect cellular contents and to overcome interferents' autofluorescence, which hinders probe signal visualization. Nevertheless, this work shows that the PNA-FISH approach could be a promising alternative for the rapid (3-4 h) and accurate detection of Legionella.
Collapse
Affiliation(s)
- Montserrat Nácher-Vázquez
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- INIAV, IP—National Institute for Agrarian and Veterinary Research, Vairão, 4485-655 Vila Do Conde, Portugal;
| | - Ana Barbosa
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Inês Armelim
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
| | - Andreia Sofia Azevedo
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
- i3S—Instituto de Investigação e Inovação em Saúde, Universidade do Porto, 4200-135 Porto, Portugal
- IPATIMUP—Instituto de Patologia e Imunologia Molecular, Universidade do Porto, 4200-135 Porto, Portugal
| | - Gonçalo Nieto Almeida
- INIAV, IP—National Institute for Agrarian and Veterinary Research, Vairão, 4485-655 Vila Do Conde, Portugal;
| | - Cristina Pizarro
- INSA—National Institute of Health Doutor Ricardo Jorge, Rua Alexandre Herculano 321, 4000-055 Porto, Portugal;
| | - Nuno Filipe Azevedo
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Carina Almeida
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- INIAV, IP—National Institute for Agrarian and Veterinary Research, Vairão, 4485-655 Vila Do Conde, Portugal;
- Centre of Biological Engineering (CEB), University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal
| | - Laura Cerqueira
- LEPABE—Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal; (M.N.-V.); (A.B.); (I.A.); (A.S.A.); (N.F.A.); (C.A.)
- ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| |
Collapse
|
20
|
Niculita-Hirzel H, Vanhove AS, Leclerc L, Girardot F, Pourchez J, Allegra S. Risk Exposure to Legionella pneumophila during Showering: The Difference between a Classical and a Water Saving Shower System. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19063285. [PMID: 35328980 PMCID: PMC8955837 DOI: 10.3390/ijerph19063285] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/01/2022] [Accepted: 03/08/2022] [Indexed: 02/04/2023]
Abstract
The increase in legionellosis incidence in the general population in recent years calls for a better characterization of the sources of infection, such as showering. Water-efficient shower systems that use water-atomizing technology have been shown to emit slightly more inhalable particles in the range of bacterial sizes than the traditional systems; however, the actual rate of bacterial emission remains poorly documented. The aim of this study was to assess the aerosolisation rate of the opportunistic water pathogen Legionella pneumophila during showering with one shower system representative of each technology. To achieve this objective, we performed controlled experiments inside a glove box and determined the emitted dose and viability of airborne Legionella. The bioaerosols were sampled with a Coriolis® Delta air sampler and the total number of viable (cultivable and noncultivable) Legionella was determined by flow cytometry and culture. We found that the rate of viable and cultivable Legionella aerosolized from the water jet was similar between the two showerheads: the viable fraction represents 0.02% of the overall bacteria present in water, while the cultivable fraction corresponds to only 0.0005%. The two showerhead models emitted a similar ratio of airborne Legionella viable and cultivable per volume of water used. Therefore, the risk of exposure to Legionella is not expected to increase significantly with the new generation of water-efficient showerheads.
Collapse
Affiliation(s)
- Hélène Niculita-Hirzel
- Department Work, Heath & Environment, Center for Primary Care and Public Health (Unisanté), University of Lausanne, Route de la Corniche 2, CH-1066 Epalinges-Lausanne, Switzerland
- Correspondence:
| | - Audrey S. Vanhove
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| | - Lara Leclerc
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023 Saint-Etienne, France; (L.L.); (J.P.)
| | - Françoise Girardot
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| | - Jérémie Pourchez
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023 Saint-Etienne, France; (L.L.); (J.P.)
| | - Séverine Allegra
- EVS-ISTHME UMR 5600, CNRS, University Jean Monnet of Saint-Etienne, F-42023 Saint-Etienne, France; (A.S.V.); (F.G.); (S.A.)
| |
Collapse
|
21
|
Riccò M, Ferraro P, Peruzzi S, Zaniboni A, Ranzieri S. SARS-CoV-2-Legionella Co-Infections: A Systematic Review and Meta-Analysis (2020-2021). Microorganisms 2022; 10:499. [PMID: 35336074 PMCID: PMC8951730 DOI: 10.3390/microorganisms10030499] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/14/2022] [Accepted: 02/21/2022] [Indexed: 02/04/2023] Open
Abstract
Legionnaires' Disease (LD) is a severe, sometimes fatal interstitial pneumonia due to Legionella pneumophila. Since the inception of the SARS-CoV-2 pandemic, some contradictory reports about the effects of lockdown measures on its epidemiology have been published, but no summary evidence has been collected to date. Therefore, we searched two different databases (PubMed and EMBASE) focusing on studies that reported the occurrence of LD among SARS-CoV-2 cases. Data were extracted using a standardized assessment form, and the results of such analyses were systematically reported, summarized, and compared. We identified a total of 38 articles, including 27 observational studies (either prospective or retrospective ones), 10 case reports, and 1 case series. Overall, data on 10,936 SARS-CoV-2 cases were included in the analyses. Of them, 5035 (46.0%) were tested for Legionella either through urinary antigen test or PCR, with 18 positive cases (0.4%). A pooled prevalence of 0.288% (95% Confidence Interval (95% CI) 0.129-0.641), was eventually calculated. Moreover, detailed data on 19 co-infections LD + SARS-CoV-2 were obtained (males: 84.2%; mean age: 61.9 years, range 35 to 83; 78.9% with 1 or more underlying comorbidities), including 16 (84.2%) admissions to the ICU, with a Case Fatality Ratio of 26.3%. In summary, our analyses suggest that the occurrence of SARS-CoV-2-Legionella infections may represent a relatively rare but not irrelevant event, and incident cases are characterized by a dismal prognosis.
Collapse
Affiliation(s)
- Matteo Riccò
- AUSL–IRCCS di Reggio Emilia, Servizio di Prevenzione e Sicurezza Negli Ambienti di Lavoro (SPSAL), Local Health Unit of Reggio Emilia, 42122 Reggio Emilia, Italy
| | - Pietro Ferraro
- Servizio di Medicina del Lavoro, ASL di Foggia, 71121 Foggia, Italy;
| | - Simona Peruzzi
- AUSL–IRCCS di Reggio Emilia, Laboratorio Analisi Chimico Cliniche e Microbiologiche, Ospedale Civile di Guastalla, 42016 Guastalla, Italy;
| | - Alessandro Zaniboni
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (A.Z.); (S.R.)
| | - Silvia Ranzieri
- Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy; (A.Z.); (S.R.)
| |
Collapse
|
22
|
Practitioners’ Perspective on the Prevalent Water Quality Management Practices for Legionella Control in Large Buildings in the United States. WATER 2022. [DOI: 10.3390/w14040663] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Managing building water systems is complicated by the need to maintain hot water temperatures high enough to control the growth of Legionella spp. while minimizing the risk of scalding. This study assessed water quality management practices in large buildings in the United States. Surveys conducted with building water quality managers found that more than 85% of buildings have hot water temperatures that are consistent with scald risk mitigation guidelines (i.e., <122 °F/50 °C). However, nearly two thirds and three quarters of buildings do not comply with the common temperature guidance for opportunistic pathogen control, i.e., water heater setpoint > 140 °F (60 °C) and recirculation loop > 122 °F (50 °C), respectively; median values for both setpoint and recirculation loop temperatures are 10 °F (6 °C) or more below temperatures recommended for opportunistic pathogen control. These observations suggest that many buildings are prone to Legionella spp. risk. The study also found that 27% of buildings do not comply with guidelines for time to equilibrium hot water temperature, over 33% fail to monitor temperature in the recirculation loop, more than 70% fail to replace or disinfect showerheads, more than 40% lack a written management plan, and only a minority conduct any monitoring of residual disinfectant levels or microbiological quality. Given the rise in Legionellosis infections in recent years, coupled with highlighted water quality concerns because of prolonged water stagnation in plumbing, such as in buildings closed due to COVID-19, current management practices, which appear to be focused on scald risk, may need to be broadened to include greater attention to control of opportunistic pathogens. To accomplish this, there is a need for formal training and resources for facility managers.
Collapse
|
23
|
Quantitative Microbial Risk Assessment Applied to Legionella Contamination on Long-Distance Public Transport. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19041960. [PMID: 35206148 PMCID: PMC8872098 DOI: 10.3390/ijerph19041960] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/07/2022] [Accepted: 02/09/2022] [Indexed: 01/01/2023]
Abstract
The quantitative microbial risk assessment (QMRA) framework is used for assessing health risk coming from pathogens in the environment. In this paper, we used QMRA to evaluate the infection risk of L. pneumophila attributable to sink usage in a toilet cabin on Italian long-distance public transportation (LDT). LDT has water distribution systems with risk points for Legionella proliferation, as well as premise plumbing for drinking water, but they are not considered for risk assessment. Monitoring data revealed that approximately 55% of water samples (217/398) were positive for L. pneumophila, and the most frequently isolated was L. pneumophila sg1 (64%, 139/217); therefore, such data were fitted to the best probability distribution function to be used as a stochastic variable in the QMRA model. Then, a sink-specific aerosolization ratio was applied to calculate the inhaled dose, also considering inhalation rate and exposure time, which were used as stochastic parameters based on literature data. At L. pneumophila sg1 concentration ≤100 CFU/L, health risk was approximately 1 infection per 1 million exposures, with an increase of up to 5 infections per 10,000 exposures when the concentrations were ≥10,000 CFU/L. Our QMRA results showed a low Legionella infection risk from faucets on LDT; however, it deserves consideration since LDT can be used by people highly susceptible for the development of a severe form of the disease, owing to their immunological status or other predisposing factors. Further investigations could also evaluate Legionella-laden aerosols from toilet flushing.
Collapse
|
24
|
Talapko J, Frauenheim E, Juzbašić M, Tomas M, Matić S, Jukić M, Samardžić M, Škrlec I. Legionella pneumophila-Virulence Factors and the Possibility of Infection in Dental Practice. Microorganisms 2022; 10:microorganisms10020255. [PMID: 35208710 PMCID: PMC8879694 DOI: 10.3390/microorganisms10020255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/08/2022] [Accepted: 01/21/2022] [Indexed: 02/07/2023] Open
Abstract
Legionella pneumophila is defined as a bacterium that can cause severe pneumonia. It is found in the natural environment and in water, and is often found in water tanks. It can be an integral part of biofilms in nature, and the protozoa in which it can live provide it with food and protect it from harmful influences; therefore, it has the ability to move into a sustainable but uncultured state (VBNC). L. pneumophila has been shown to cause infections in dental practices. The most common transmission route is aerosol generated in dental office water systems, which can negatively affect patients and healthcare professionals. The most common way of becoming infected with L. pneumophila in a dental office is through water from dental instruments, and the dental unit. In addition to these bacteria, patients and the dental team may be exposed to other harmful bacteria and viruses. Therefore, it is vital that the dental team regularly maintains and decontaminates the dental unit, and sterilizes all accessories that come with it. In addition, regular water control in dental offices is necessary.
Collapse
Affiliation(s)
- Jasminka Talapko
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Erwin Frauenheim
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Martina Juzbašić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Matej Tomas
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Suzana Matić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- Faculty of Medicine, Josip Juraj Strossmayer University of Osijek, Josipa Huttlera 4, HR-31000 Osijek, Croatia
| | - Melita Jukić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- General Hospital Vukovar, Županijska 35, HR-32000 Vukovar, Croatia
| | - Marija Samardžić
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
| | - Ivana Škrlec
- Faculty of Dental Medicine and Health, Josip Juraj Strossmayer University of Osijek, HR-31000 Osijek, Croatia; (J.T.); (E.F.); (M.J.); (M.T.); (S.M.); (M.J.); (M.S.)
- Correspondence:
| |
Collapse
|
25
|
Tartakovsky IS, Maleev VV. Legionnaires disease: history of the discovery, the main stages of the study pathogen and infection. TERAPEVT ARKH 2022; 94:145-148. [DOI: 10.26442/00403660.2022.01.201327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 03/14/2022] [Indexed: 11/22/2022]
Abstract
The article discusses main directions and stages of the 45 years of Legionnaires disease study. Analysis of epidemiology and laboratory diagnostics of infection show as unknown until 1976 microorganism occupied a notable niche in the etiology of severe pneumonia. Control and monitoring of potential dangerous water systems, generating water aerosol containing Legionella in high concentration, plays a major role in the prevention of Legionnaires disease.
Collapse
|
26
|
Bavari S, Mirkalantari S, Masjedian Jazi F, Darban-Sarokhalil D, Golnari Marani B. Risk assessment and quantitative measurement along with monitoring of Legionella in hospital water sources. New Microbes New Infect 2022; 45:100948. [PMID: 35399198 PMCID: PMC8984627 DOI: 10.1016/j.nmni.2021.100948] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 08/21/2021] [Accepted: 12/20/2021] [Indexed: 11/25/2022] Open
Abstract
Legionella spp. as a causative agent of Legionnaires' disease (LD) and an opportunistic pathogen creates a public health problem. Isolation and quantification of this bacteria from clinic water sources are essential for hazard appraisal and sickness avoidance. This study aimed at risk assessment and quantitative measurement along with Legionella monitoring in educational hospital water sources in Tehran, Iran. A cross-sectional study was carried out in 1 year. The conventional culture method was used in this study to isolate Legionella from water samples. The polymerase chain reaction (PCR) technique was used to confirm the identity of the isolates and ensure that they were all Legionella. Quantitative PCR (qPCR) was used to determine the count of bacteria, and HeLa cell culture was used to determine the invasion of isolates. A total of 100 water samples were collected and inoculated on GVPC (glycine, vancomycin, polymyxin, and cycloheximide) agar; 12 (12%) and 42 (42%) cases were culture and PCR positive, respectively. Percentage of Legionella presence in PCR-positive samples by the qPCR method in <103 GU/L, in about 103 and lower than 104 GU/L, and in 104 GU/L was 40.47 (17 cases), 4.76% (two cases), and 54.76% (23 cases), respectively. Invasion analysis revealed that five and four isolates had invaded HeLa cells more than twice and equally, respectively, and the others had a lower invasion than the reference strain. The findings revealed that the spread of LD in hospitals was linked to the water system. Given the importance of nosocomial infections in the medical community, establishing a hospital water monitoring system is the most effective way to control these infections, particularly Legionella infections.
Collapse
|
27
|
Jalili M, Ehrampoush MH, Zandi H, Ebrahimi AA, Mokhtari M, Samaei MR, Abbasi F. Risk assessment and disease burden of legionella presence in cooling towers of Iran's central hospitals. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:65945-65951. [PMID: 34327641 DOI: 10.1007/s11356-021-14791-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 07/27/2020] [Indexed: 06/13/2023]
Abstract
Regular monitoring and measurement of Legionella in tower water and preventive measures against contamination are particularly important in hospitals. This study aimed at risk assessment and disease burden because of legionella presence in cooling towers of Iran's central hospitals. Then its correlation with temperature, pH, turbidity, residual chlorine, and EC was investigated by the Pearson test. The health risk and burden of diseases caused by Legionella exposure were determined using QMRA and DALY models. Statistical analysis and modeling were performed in MATLAB2018. Of the total samples, 30-43% was infected with Legionella. The mean concentrations in hospital A and B were 5-102.5 ± 10 and 5-89.7 ± 0.7 CFU/L, respectively. Among environmental factors, turbidity and pH were the most effective factors in increasing and decreasing Legionella concentration, respectively. According to the QMRA model, the risks of Legionella infections and annual mortality in both hospitals were 0.2-0.3, 0-0.19, 2-2.9 × 10-5, and 0-0.7 × 10-5, respectively, which was higher than the acceptable risk range for Legionella (10-4-10-7). However, the trend of its change was negatively correlated with time (RB = - 0.77). According to the results, the concentration of Legionella and the exposure risk in both hospitals were higher than the permissible range, which is necessary to decrease to 0.1 current concentrations.
Collapse
Affiliation(s)
- Mahrokh Jalili
- Department of Environmental Health Engineering, Genetic and Environmental Adventures Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
- Student Research Committee, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
- Department of Environmental Health Engineering, Environmental Science and Technology Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Mohammad Hassan Ehrampoush
- Department of Environmental Health Engineering, Genetic and Environmental Adventures Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Hengameh Zandi
- Department of Microbiology, School of Public Health, Research Center for Food Hygiene and Safety, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Ali Asghar Ebrahimi
- Department of Environmental Health Engineering, Genetic and Environmental Adventures Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Mehdi Mokhtari
- Department of Environmental Health Engineering, Genetic and Environmental Adventures Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Mohammad Reza Samaei
- Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Fariba Abbasi
- Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
28
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
29
|
Riccò M, Peruzzi S, Ranzieri S, Giuri PG. Epidemiology of Legionnaires' Disease in Italy, 2004-2019: A Summary of Available Evidence. Microorganisms 2021; 9:microorganisms9112180. [PMID: 34835307 PMCID: PMC8624895 DOI: 10.3390/microorganisms9112180] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 10/14/2021] [Accepted: 10/18/2021] [Indexed: 01/11/2023] Open
Abstract
Legionnaires’ disease (LD) incidence has been increasing in several European countries since 2011. Currently, Italy is experiencing high notification rates for LD, whose cause still remains scarcely understood. We sought to summarize the available evidence on the epidemiology of LD in Italy (2004–2019), characterizing the risk of LD by region, sex, age group, and settings of the case (i.e., community, healthcare, or travel-associated cases). Environmental factors (e.g., average air temperatures and relative humidity) were also included in a Poisson regression model in order to assess their potential role on the annual incidence of new LD cases. National surveillance data included a total of 23,554 LD cases occurring between 2004 and 2019 (70.4% of them were of male gender, 94.1% were aged 40 years and older), with age-adjusted incidence rates increasing from 1.053 cases per 100,000 in 2004 to 4.559 per 100,000 in 2019. The majority of incident cases came from northern Italy (43.2% from northwestern Italy, 25.6% from northeastern Italy). Of these, 5.9% were healthcare-related, and 21.1% were travel-associated. A case-fatality ratio of 5.2% was calculated for the whole of the assessed timeframe, with a pooled estimate for mortality of 0.122 events per 100,000 population per year. Poisson regression analysis was associated with conflicting results, as any increase in average air temperature resulted in reduced risk for LD cases (Incidence Rate Ratio [IRR] 0.807, 95% Confidence Interval [95% CI] 0.744–0.874), while higher annual income in older individuals was associated with an increased IRR (1.238, 95% CI 1.134–1.351). The relative differences in incidence between Italian regions could not be explained by demographic factors (i.e., age and sex distribution of the population), and also a critical reappraisal of environmental factors failed to substantiate both the varying incidence across the country and the decennial trend we were able to identify.
Collapse
Affiliation(s)
- Matteo Riccò
- Servizio di Prevenzione e Sicurezza Negli Ambienti di Lavoro (SPSAL), AUSL—IRCCS di Reggio Emilia, Via Amendola n.2, I-42022 Reggio Emilia, Italy
- Correspondence: or ; Tel.: +39-3392-994-343 or +39-522-837-587
| | - Simona Peruzzi
- Laboratorio Analisi Chimico Cliniche e Microbiologiche, Ospedale Civile di Guastalla, AUSL—IRCCS di Reggio Emilia, I-42016 Guastalla, Italy;
| | - Silvia Ranzieri
- Department of Medicine and Surgery, School of Occupational Medicine, University of Parma, Via Gramsci n.14, I-43123 Parma, Italy;
| | - Pasquale Gianluca Giuri
- Dipartimento Internistico Interaziendale, Struttura Operativa Semplice Dipartimentale “Medicina Infettivologica”, AUSL—IRCCS di Reggio Emilia, Ospedale “Sant’Anna”, I-42035 Castelnovo ne’ Monti, Italy;
| |
Collapse
|
30
|
Bacterial Long-Range Warfare: Aerial Killing of Legionella pneumophila by Pseudomonas fluorescens. Microbiol Spectr 2021; 9:e0040421. [PMID: 34378969 PMCID: PMC8552673 DOI: 10.1128/spectrum.00404-21] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Legionella pneumophila, the causative agent of Legionnaires’ disease, is mostly found in man-made water systems and is one of the most closely monitored waterborne pathogens. With the aim of finding natural ways to control waterborne pathogens and thus further reduce the impact of disinfection by-products on human health, some studies have demonstrated the ability of bacteria to kill Legionella through the production of secondary metabolites or antimicrobial compounds. Here, we describe an unexpected growth inhibition of L. pneumophila when exposed to a physically separated strain of Pseudomonas fluorescens, designated as MFE01. Most of the members of the Legionellaceae family are sensitive to the volatile substances emitted by MFE01, unlike other bacteria tested. Using headspace solid-phase microextraction GC-MS strategy, a volatilome comparison revealed that emission of 1-undecene, 2-undecanone, and 2-tridecanone were mainly reduced in a Tn5-transposon mutant unable to inhibit at distance the growth of L. pneumophila strain Lens. We showed that 1-undecene was mainly responsible for the inhibition at distance in vitro, and led to cell lysis in small amounts, as determined by gas chromatography-mass spectrometry (GC-MS). Collectively, our results provide new insights into the mode of action of bacterial volatiles and highlight them as potent anti-Legionella agents to focus research on novel strategies to fight legionellosis. IMPORTANCE Microbial volatile compounds are molecules whose activities are increasingly attracting the attention of researchers. Indeed, they can act as key compounds in long-distance intrakingdom and interkingdom communication, but also as antimicrobials in competition and predation. In fact, most studies to date have focused on their antifungal activities and only a few have reported on their antibacterial properties. Here, we describe that 1-undecene, naturally produced by P. fluorescens, is a volatile with potent activity against bacteria of the genus Legionella. In small amounts, it is capable of inducing cell lysis even when the producing strain is physically separated from the target. This is the first time that such activity is described. This molecule could therefore constitute an efficient compound to counter bacterial pathogens whose treatment may fail, particularly in pulmonary diseases. Indeed, inhalation of these volatiles should be considered as a possible route of therapy in addition to antibiotic treatment.
Collapse
|
31
|
Hospital-acquired Legionella pneumonia outbreak at an academic medical center: Lessons learned. Am J Infect Control 2021; 49:1014-1020. [PMID: 33631307 DOI: 10.1016/j.ajic.2021.02.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 11/21/2022]
Abstract
BACKGROUND An outbreak of Legionella pneumonia occurred at a university hospital using copper-silver ionization for potable water disinfection. We present the epidemiological and laboratory investigation of the outbreak, and associated case-control study. METHODS Cases were defined by syndrome compatible with Legionella pneumonia with laboratory-confirmed Legionella infection. The water circuit and disinfection system were assessed, and water samples collected for Legionella culture. Whole genome multi-locus sequence typing (wgMLST) was used to compare the genetic similarity of patient and environmental isolates. A case-control study was conducted to identify risk factors for Legionella pneumonia. RESULTS We identified 13 cases of hospital-acquired Legionella. wgMLST revealed >99.9% shared allele content among strains isolated from clinical and water samples. Smoking (P= .008), steroid use (P= .007), and documented shower during hospitalization (P= .03) were risk factors for Legionella pneumonia on multivariable analysis. Environmental assessment identified modifications to the hospital water system had occurred in the month preceding the outbreak. Multiple mitigation efforts and application of point of use water filters stopped the outbreak. CONCLUSIONS Potable water system Legionella colonization occurs despite existing copper-silver ionization systems, particularly after structural disruptions. Multidisciplinary collaboration and direct monitoring for Legionella are important for outbreak prevention. Showering is a modifiable risk factor for nosocomial Legionella pneumonia. Shower restriction and point-of-use filters merit consideration during an outbreak.
Collapse
|
32
|
Hamilton KA, Kuppravalli A, Heida A, Joshi S, Haas CN, Verhougstraete M, Gerrity D. Legionnaires' disease in dental offices: Quantifying aerosol risks to dental workers and patients. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2021; 18:378-393. [PMID: 34161202 DOI: 10.1080/15459624.2021.1939878] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Legionella pneumophila is an opportunistic bacterial respiratory pathogen that is one of the leading causes of drinking water outbreaks in the United States. Dental offices pose a potential risk for inhalation or aspiration of L. pneumophila due to the high surface area to volume ratio of dental unit water lines-a feature that is conducive to biofilm growth. This is coupled with the use of high-pressure water devices (e.g., ultrasonic scalers) that produce fine aerosols within the breathing zone. Prior research confirms that L. pneumophila occurs in dental unit water lines, but the associated human health risks have not been assessed. We aimed to: (1) synthesize the evidence for transmission and management of Legionnaires' disease in dental offices; (2) create a quantitative modeling framework for predicting associated L. pneumophila infection risk; and (3) highlight influential parameters and research gaps requiring further study. We reviewed outbreaks, management guidance, and exposure studies and used these data to parameterize a quantitative microbial risk assessment (QMRA) model for L. pneumophila in dental applications. Probabilities of infection for dental hygienists and patients were assessed on a per-exposure and annual basis. We also assessed the impact of varying ventilation rates and the use of personal protective equipment (PPE). Following an instrument purge (i.e., flush) and with a ventilation rate of 1.2 air changes per hour, the median per-exposure probability of infection for dental hygienists and patients exceeded a 1-in-10,000 infection risk benchmark. Per-exposure risks for workers during a purge and annual risks for workers wearing N95 masks did not exceed the benchmark. Increasing air change rates in the treatment room from 1.2 to 10 would achieve an ∼85% risk reduction, while utilization of N95 respirators would reduce risks by ∼95%. The concentration of L. pneumophila in dental unit water lines was a dominant parameter in the model and driver of risk. Future risk assessment efforts and refinement of microbiological control protocols would benefit from expanded occurrence datasets for L. pneumophila in dental applications.
Collapse
Affiliation(s)
- Kerry A Hamilton
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, Arizona
- The Biodesign Institute Center for Environmental Health Engineering, Arizona State University, Tempe, Arizona
| | - Aditya Kuppravalli
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, Arizona
- The Biodesign Institute Center for Environmental Health Engineering, Arizona State University, Tempe, Arizona
- BASIS Scottsdale High School, Scottsdale, Arizona
| | - Ashley Heida
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, Arizona
- The Biodesign Institute Center for Environmental Health Engineering, Arizona State University, Tempe, Arizona
| | - Sayalee Joshi
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, Arizona
- The Biodesign Institute Center for Environmental Health Engineering, Arizona State University, Tempe, Arizona
| | - Charles N Haas
- Department of Civil, Architectural, and Environmental Engineering, Drexel University, Philadelphia, Pennsylvania
| | - Marc Verhougstraete
- Mel and Enid Zuckerman College of Public Health, The University of Arizona, Tucson, Arizona
| | | |
Collapse
|
33
|
Beauté J, Plachouras D, Sandin S, Giesecke J, Sparén P. Healthcare-Associated Legionnaires' Disease, Europe, 2008-2017. Emerg Infect Dis 2021; 26:2309-2318. [PMID: 32946366 PMCID: PMC7510712 DOI: 10.3201/eid2610.181889] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Healthcare-associated Legionnaires’ disease (HCA LD) can cause nosocomial outbreaks with high death rates. We compared community-acquired LD cases with HCA LD cases in Europe during 2008−2017 using data from The European Surveillance System. A total of 29 countries reported 40,411 community-acquired and 4,315 HCA LD cases. Of the HCA LD cases, 2,937 (68.1%) were hospital-acquired and 1,378 (31.9%) were linked to other healthcare facilities. The odds of having HCA LD were higher for women, children and persons <20 years of age, and persons >60 years of age. Out of the cases caused by Legionella pneumophila with a known serotype, community-acquired LD was more likely to be caused by L. pneumophila serogroup 1 (92.3%) than was HCA LD (85.1%). HCA LD patients were more likely to die. HCA LD is associated with specific patient demographics, causative strains, and outcomes. Healthcare facilities should consider these characteristics when designing HCA LD prevention strategies.
Collapse
|
34
|
Letter to the Editor regarding the article "Outbreaks of Legionnaires' Disease and Pontiac Fever 2006-2017". Curr Environ Health Rep 2021; 9:120-122. [PMID: 34003468 PMCID: PMC8983519 DOI: 10.1007/s40572-021-00319-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
35
|
Saini N, Gupta RS. A robust phylogenetic framework for members of the order Legionellales and its main genera (Legionella, Aquicella, Coxiella and Rickettsiella) based on phylogenomic analyses and identification of molecular markers demarcating different clades. Antonie van Leeuwenhoek 2021; 114:957-982. [PMID: 33881638 DOI: 10.1007/s10482-021-01569-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 04/01/2021] [Indexed: 12/29/2022]
Abstract
The order Legionellales contains several clinically important microorganisms. Although members of this order are well-studied for their pathogenesis, there is a paucity of reliable characteristics distinguishing members of this order and its constituent genera. Genome sequences are now available for 73 Legionellales species encompassing ≈90% of known members from different genera. With the aim of understanding evolutionary relationships and identifying reliable molecular characteristics that are specific for this order and its constituent genera, detailed phylogenetic and comparative analyses were conducted on the protein sequences from these genomes. A phylogenomic tree was constructed based on 393 single copy proteins that are commonly shared by the members of this order to delineate the evolutionary relationships among its members. In parallel, comparative analyses were performed on protein sequences from Legionellales genomes to identify novel molecular markers consisting of conserved signature indels (CSIs) that are specific for different clades and genera. In the phylogenomic tree and in an amino acid identity matrix based on core proteins, members of the genera Aquicella, Coxiella, Legionella and Rickettsiella formed distinct clades confirming their monophyly. In these studies, Diplorickettsia massiliensis exhibited a close relationship to members of the genus Rickettsiella. The results of our comparative genomic analyses have identified 59 highly specific molecular markers consisting of CSIs in diverse proteins that are uniquely shared by different members of this order. Four of these CSIs are specific for all Legionellales species, except the two deeper-branching "Candidatus Berkiella" species, providing means for identifying members of this order in molecular terms. Twenty four, 7 and 6 CSIs are uniquely shared by members of the genera Legionella, Coxiella and Aquicella, respectively, identifying these groups in molecular terms. The descriptions of these three genera are emended to include information for their novel molecular characteristics. We also describe 12 CSIs that are uniquely shared by D. massiliensis and different members of the genus Rickettsiella. Based on these results, we are proposing an integration of the genus Diplorickettsia with Rickettsiella. Three other CSIs suggest that members of the genera Coxiella and Rickettsiella shared a common ancestor exclusive of other Legionellales. The described molecular markers, due to their exclusivity for the indicated taxa/genera, provide important means for the identification of these clinically important microorganisms and for discovering novel properties unique to them.
Collapse
Affiliation(s)
- Navneet Saini
- Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, ON, L8N 3Z5, Canada
| | - Radhey S Gupta
- Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, ON, L8N 3Z5, Canada.
| |
Collapse
|
36
|
Chauhan D, Shames SR. Pathogenicity and Virulence of Legionella: Intracellular replication and host response. Virulence 2021; 12:1122-1144. [PMID: 33843434 PMCID: PMC8043192 DOI: 10.1080/21505594.2021.1903199] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Bacteria of the genus Legionella are natural pathogens of amoebae that can cause a severe pneumonia in humans called Legionnaires’ Disease. Human disease results from inhalation of Legionella-contaminated aerosols and subsequent bacterial replication within alveolar macrophages. Legionella pathogenicity in humans has resulted from extensive co-evolution with diverse genera of amoebae. To replicate intracellularly, Legionella generates a replication-permissive compartment called the Legionella-containing vacuole (LCV) through the concerted action of hundreds of Dot/Icm-translocated effector proteins. In this review, we present a collective overview of Legionella pathogenicity including infection mechanisms, secretion systems, and translocated effector function. We also discuss innate and adaptive immune responses to L. pneumophila, the implications of Legionella genome diversity and future avenues for the field.
Collapse
Affiliation(s)
- Deepika Chauhan
- Division of Biology, Kansas State University, Manhattan, Kansas, USA
| | | |
Collapse
|
37
|
A Methodology for Classifying Root Causes of Outbreaks of Legionnaires' Disease: Deficiencies in Environmental Control and Water Management. Microorganisms 2021; 9:microorganisms9010089. [PMID: 33401429 PMCID: PMC7824450 DOI: 10.3390/microorganisms9010089] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 12/23/2020] [Accepted: 12/27/2020] [Indexed: 12/03/2022] Open
Abstract
We piloted a methodology for collecting and interpreting root cause—or environmental deficiency (ED)—information from Legionnaires’ disease (LD) outbreak investigation reports. The methodology included a classification framework to assess common failures observed in the implementation of water management programs (WMPs). We reviewed reports from fourteen CDC-led investigations between 1 January 2015 and 21 June 2019 to identify EDs associated with outbreaks of LD. We developed an abstraction guide to standardize data collection from outbreak reports and define relevant parameters. We categorized each ED according to three criteria: ED type, WMP-deficiency type, and source of deficiency. We calculated the prevalence of EDs among facilities and explored differences between facilities with and without WMPs. A majority of EDs identified (81%) were classified as process failures. Facilities with WMPs (n = 8) had lower prevalence of EDs attributed to plumbed devices (9.1%) and infrastructure design (0%) than facilities without WMPs (n = 6; 33.3% and 24.2%, respectively). About three quarters (72%) of LD cases and 81% of the fatalities in our sample originated at facilities without a WMP. This report highlights the importance of WMPs in preventing and mitigating outbreaks of LD. Building water system process management is a primary obstacle toward limiting the root causes of LD outbreaks. Greater emphasis on the documentation, verification, validation, and continuous program review steps will be important in maximizing the effectiveness of WMPs.
Collapse
|
38
|
Proteomics and Lipidomics Investigations to Decipher the Behavior of Willaertia magna C2c Maky According to Different Culture Modes. Microorganisms 2020; 8:microorganisms8111791. [PMID: 33207645 PMCID: PMC7696429 DOI: 10.3390/microorganisms8111791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 11/12/2020] [Accepted: 11/14/2020] [Indexed: 11/17/2022] Open
Abstract
Willaertia magna C2c Maky is a free-living amoeba that has demonstrated its ability to inhibit the intracellular multiplication of some Legionella pneumophila strains, which are pathogenic bacteria inhabiting the aquatic environment. The Amoeba, an industry involved in the treatment of microbiological risk in the water and plant protection sectors, has developed a natural biocide based on the property of W. magna to manage the proliferation of the pathogen in cooling towers. In axenic liquid medium, amoebas are usually cultivated in adhesion on culture flask. However, we implemented a liquid culture in suspension using bioreactors in order to produce large quantities of W. magna. In order to investigate the culture condition effects on W. magna, we conducted a study based on microscopic, proteomics and lipidomics analyzes. According to the culture condition, amoeba exhibited two different phenotypes. The differential proteomics study showed that amoebas seemed to promote the lipid metabolism pathway in suspension culture, whereas we observed an upregulation of the carbohydrate pathway in adherent culture. Furthermore, we observed an over-regulation of proteins related to the cytoskeleton for W. magna cells grown in adhesion. Regarding the lipid analysis, suspension and adhesion cell growth showed comparable lipid class compositions. However, the differential lipid analysis revealed differences that confirmed cell phenotype differences observed by microscopy and predicted by proteomics. Overall, this study provides us with a better insight into the biology and molecular processes of W. magna in different culture lifestyles.
Collapse
|
39
|
Li L, Liu H, Wang Y, Han X, Ge T, Pan L. Construction of a nomogram for predicting the risk of allergic rhinitis among employees of long-distance bus stations in China. INDOOR AIR 2020; 30:1178-1188. [PMID: 32445588 DOI: 10.1111/ina.12694] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 03/30/2020] [Accepted: 05/11/2020] [Indexed: 06/11/2023]
Abstract
This study examined indoor air pollutants and their health effects on allergic rhinitis in 3194 employees of 226 bus station halls and then constructed a nomogram model to predict allergic rhinitis risk in those employees. Indoor air temperature, relative humidity, PM10 , PM2.5 , total bacteria, and total fungi were measured, and questionnaires were used to collect basic station information and employee health information. The results revealed that the over-standard rates of PM10 , PM2.5 , total bacteria, and total fungi were 18.16%, 31.13%, 2.22%, and 55.89%, respectively. Seasonal variations were found in temperature, relative humidity, and PM2.5 . Passenger flow could affect temperature, and total bacteria. Central air conditioning could affect total bacteria. A total of 15.90% of the employees were diagnosed as allergic rhinitis by physicians. Relative humidity, fungi, self-reported allergic rhinitis symptoms, and exposure to smoking were the influencing factors for allergic rhinitis. These four variables were incorporated to construct a nomogram. The concordance index of the nomogram was 0.775 (95% CI: 0.745-0.806) and 0.749 (95% CI: 0.715-0.783) for the training cohort and test cohort, respectively. The calibration plot revealed that the nomogram model exhibited good discrimination and consistency. This nomogram model may help predict the occurrence of allergic rhinitis.
Collapse
Affiliation(s)
- Li Li
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Hang Liu
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Yu Wang
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Xu Han
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Tanxi Ge
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| | - Lijun Pan
- China CDC Key Laboratory of Environment and Population Health, National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing, China
| |
Collapse
|
40
|
Evaluation of GVPC and BCYE Media for Legionella Detection and Enumeration in Water Samples by ISO 11731: Does Plating on BCYE Medium Really Improve Yield? Pathogens 2020; 9:pathogens9090757. [PMID: 32948082 PMCID: PMC7559527 DOI: 10.3390/pathogens9090757] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/14/2020] [Accepted: 09/15/2020] [Indexed: 11/19/2022] Open
Abstract
Legionella spp are the causative agents of Legionnaires’ diseases, which is a pneumonia of important public health concern. Ubiquitous freshwater and soil inhabitants can reach man-made water systems and cause illness. Legionella enumeration and quantification in water systems is crucial for risk assessment and culture examination is the gold standard method. In this study, Legionella recovery from potable water samples, at presumably a low concentration of interfering microorganisms, was compared by plating on buffered charcoal yeast extract (BCYE) and glycine, vancomycin, polymyxin B, cycloheximide (GVPC) Legionella agar media, according to the International Standard Organization (ISO) 11731: 2017. Overall, 556 potable water samples were analyzed and 151 (27.1%) were positive for Legionella. Legionella grew on both BCYE and GVPC agar plates in 85/151 (56.3%) water samples, in 65/151 (43%) on only GVPC agar plates, and in 1/151 (0.7%) on only BCYE agar plates. In addition, GVPC medium identified Legionella species other than pneumophila in six more samples as compared with the culture on BCYE. Although the medians of colony forming units per liter (CFU/L) detected on the BCYE and GVPC agar plates were 2500 and 1350, respectively (p-value < 0.0001), the difference did not exceed one logarithm, and therefore is not relevant for Legionella risk assessment. These results make questionable the need to utilize BCYE agar plates to analyze potable water samples.
Collapse
|
41
|
Rasheduzzaman M, Singh R, Haas CN, Gurian PL. Required water temperature in hotel plumbing to control Legionella growth. WATER RESEARCH 2020; 182:115943. [PMID: 32590203 DOI: 10.1016/j.watres.2020.115943] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/12/2020] [Accepted: 05/13/2020] [Indexed: 05/07/2023]
Abstract
Legionella spp. occurring in hotel hot water systems, in particular Legionella pneumophila, are causing serious pneumonic infections, and water temperature is a key factor to control their occurrence in plumbing systems. We performed a systematic review and meta-analyses of the available evidence on the association between water temperature and Legionella colonization to identify the water temperature in hotel hot water systems required for control of Legionella. Qualitative synthesis and quantitative analysis were performed on 13 studies that met our inclusion criteria to identify the effect of temperature. The Receiver Operating Characteristic (ROC) curve identified 55 °C as a cutoff point for hotel hot water temperature with an Area Under the Curve (AUC) value of 0.914. The odds ratios (OR) for detecting Legionella at temperatures >55 °C compared to lower temperatures from a meta-analysis of three studies was 0.17 [95% CI: 0.11, 0.25], which indicates a strong negative association between temperature and Legionella colonization. A logistic regression on results from multiple studies using both molecular and culture methods found a temperature of 59 °C associated with an 8% probability of detectable Legionella. Only two studies reported sufficiently detailed data to allow a model of concentration vs. temperature to be fit, and this model was not statistically significant. Additional research or more detailed reporting of existing datasets is required to assess if Legionella growth can be limited below particular concentration targets at different temperatures.
Collapse
Affiliation(s)
- Md Rasheduzzaman
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA.
| | - Rajveer Singh
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| | - Charles N Haas
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| | - Patrick L Gurian
- Department of Civil, Architectural and Environmental Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA, 19104, USA
| |
Collapse
|
42
|
Performance of Legiolert Test vs. ISO 11731 to Confirm Legionella pneumophila Contamination in Potable Water Samples. Pathogens 2020; 9:pathogens9090690. [PMID: 32842454 PMCID: PMC7560050 DOI: 10.3390/pathogens9090690] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/21/2020] [Accepted: 08/21/2020] [Indexed: 12/15/2022] Open
Abstract
Detection and enumeration of Legionella in water samples is of great importance for risk assessment analysis. The plate culture method is the gold standard, but has received several well-known criticisms, which have induced researchers to develop alternative methods. The purpose of this study was to compare Legionella counts obtained by the analysis of potable water samples through the plate culture method and through the IDEXX liquid culture Legiolert method. Legionella plate culture, according to ISO 11731:1998, was performed using 1 L of water. Legiolert was performed using both the 10 mL and 100 mL Legiolert protocols. Overall, 123 potable water samples were analyzed. Thirty-seven (30%) of them, positive for L. pneumophila, serogroups 1 or 2–14 by plate culture, were used for comparison with the Legiolert results. The Legiolert 10 mL test detected 34 positive samples (27.6%) and the Legiolert 100 mL test detected 37 positive samples, 27.6% and 30% respectively, out of the total samples analyzed. No significant difference was found between either the Legiolert 10 mL and Legiolert 100 mL vs. the plate culture (p = 0.9 and p = 0.3, respectively) or between the Legiolert 10 mL and Legiolert 100 mL tests (p = 0.83). This study confirms the reliability of the IDEXX Legiolert test for Legionella pneumophila detection and enumeration, as already shown in similar studies. Like the plate culture method, the Legiolert assay is also suitable for obtaining isolates for typing purposes, relevant for epidemiological investigations.
Collapse
|
43
|
Firuzi P, Asl Hashemi A, Samadi Kafil H, Gholizadeh P, Aslani H. Comparative study on the microbial quality in the swimming pools disinfected by the ozone-chlorine and chlorine processes in Tabriz, Iran. ENVIRONMENTAL MONITORING AND ASSESSMENT 2020; 192:516. [PMID: 32666262 DOI: 10.1007/s10661-020-08470-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Accepted: 07/01/2020] [Indexed: 06/11/2023]
Abstract
Applying a desirable disinfestation process is necessary to control the pathogenic microorganisms in the swimming pools and prevent both dermal and intestinal effects. Therefore, the present study was conducted to compare the bacterial community and diversity in the two swimming pools disinfected by the chlorine and ozone (O3)-chlorine processes. A total of 24 samples were taken from the two swimming pools in three distinct seasons to analyze the bacterial and physico-chemical indicators. Culture and molecular methods were used to evaluate the microbial quality. Two sets of sample taken from the pools with the maximum swimmer load in the summer were investigated by the next-generation sequencing (NGS) technique. In total, 410 and 406 bacterial species were identified in the chlorine- and ozone-chlorine-disinfected pools, respectively. Among the eight dominant bacterial species in each swimming pool, Pseudomonas alcaliphila, Pseudomonas stutzeri, and Pseudomonas acnes were common species between the two studied pools. Oleomonas sagaranensis (350 reads/18593), Staphylococcus caprae (302 reads /18593), and Anaerococcus octavius (110 reads/18593) were among the dominant bacteria in the chlorine-disinfected pool. Bacterial diversity was lower in the ozone-chlorine-disinfected pool than the other one, and the highest bacterial sequencing belonged to the genus Pseudomonas (85.79%). Results showed that water quality of in O3-chlorine-disinfected pool was more desirable than the chlorine-disinfected pool. Molecular methods along with conventional culture methods would be advantageous for microbial assessment in the swimming pools.
Collapse
Affiliation(s)
- Parisa Firuzi
- Department of Environmental Health Engineering, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Ahmad Asl Hashemi
- Department of Environmental Health Engineering, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hossein Samadi Kafil
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Pourya Gholizadeh
- Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hassan Aslani
- Health and Environment Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
44
|
Allegra S, Riffard S, Leclerc L, Girardot F, Stauffert M, Forest V, Pourchez J. A valuable experimental setup to model exposure to Legionella's aerosols generated by shower-like systems. WATER RESEARCH 2020; 172:115496. [PMID: 31972415 DOI: 10.1016/j.watres.2020.115496] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Revised: 01/07/2020] [Accepted: 01/08/2020] [Indexed: 06/10/2023]
Abstract
The mechanism underlying Legionella aerosolization and entry into the respiratory tract remains poorly documented. In previous studies, we characterized the aerodynamic behaviour of Legionella aerosols and assessed their regional deposition within the respiratory tract using a human-like anatomical model. The aim of this study was to assess whether this experimental setup could mimic the exposure to bioaerosols generated by showers. To achieve this objective we performed experiments to measure the mass median aerodynamic diameter (MMAD) as well as the emitted dose and the physiological state of the airborne bacteria generated by a shower and two nebulizers (vibrating-mesh and jet nebulizers). The MMADs of the dispersed bioaerosols were characterized using a 12-stage cascade low-pressure impactor. The amount of dispersed airborne bacteria from a shower was quantified using a Coriolis® Delta air sampler and compared to the airborne bacteria reaching the thoracic region in the experimental setup. The physiological state and concentration of airborne Legionella were assessed by qPCR for total cells, culture for viable and cultivable Legionella (VC), and flow cytometry for viable but non-cultivable Legionella (VBNC). In summary, the experimental setup developed appears to mimic the bioaerosol emission of a shower in terms of aerodynamic size distribution. Compared to the specific case of a shower used as a reference in this study, the experimental setup developed underestimates by 2 times (when the jet nebulizer is used) or overestimates by 43 times (when the vibrating-mesh nebulizer is used) the total emitted dose of airborne bacteria. To our knowledge, this report is the first showing that an experimental model mimics so closely an exposure to Legionella aerosols produced by showers to assess human lung deposition and infection in well-controlled and safe conditions.
Collapse
Affiliation(s)
- Séverine Allegra
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France.
| | - Serge Riffard
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Lara Leclerc
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| | - Françoise Girardot
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Magalie Stauffert
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Valérie Forest
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| | - Jérémie Pourchez
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| |
Collapse
|
45
|
Hasni I, Jarry A, Quelard B, Carlino A, Eberst JB, Abbe O, Demanèche S. Intracellular Behaviour of Three Legionella pneumophila Strains within Three Amoeba Strains, Including Willaertia magna C2c Maky. Pathogens 2020; 9:pathogens9020105. [PMID: 32041369 PMCID: PMC7168187 DOI: 10.3390/pathogens9020105] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 02/04/2020] [Accepted: 02/05/2020] [Indexed: 12/12/2022] Open
Abstract
Legionella pneumophila is a facultative intracellular pathogen found in aquatic environments as planktonic cells within biofilms and as intracellular parasites of free-living amoebae such as Acanthamoeba castellanii. This pathogen bypasses the elimination mechanism to replicate within amoebae; however, not all amoeba species support the growth of L. pneumophila. Willaertia magna C2c Maky, a non-pathogenic amoeba, was previously demonstrated to possess the ability to eliminate the L. pneumophila strain Paris. Here, we study the intracellular behaviour of three L. pneumophila strains (Paris, Philadelphia, and Lens) within W. magna C2c Maky and compare this strain to A. castellanii and W. magna Z503, which are used as controls. We observe the intracellular growth of strain Lens within W. magna Z503 and A. castellanii at 22 °C and 37 °C. Strain Paris grows within A. castellanii at any temperature, while it only grows at 22 °C within W. magna Z503. Strain Philadelphia proliferates only within A. castellanii at 37 °C. Within W. magna C2c Maky, none of the three legionella strains exhibit intracellular growth. Additionally, the ability of W. magna C2c Maky to decrease the number of internalized L. pneumophila is confirmed. These results support the idea that W. magna C2c Maky possesses unique behaviour in regard to L. pneumophila strains.
Collapse
Affiliation(s)
- Issam Hasni
- Microbes, Evolution, Phylogeny and Infection Department, Institut de Recherche pour le Développement IRD 198, Institut Hospitalo-Universitaire (IHU), Aix-Marseille Université, 13007 Marseille, France;
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Antoine Jarry
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Benjamin Quelard
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Antoine Carlino
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Jean-Baptiste Eberst
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Olivier Abbe
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
| | - Sandrine Demanèche
- R&D Department, Amoéba, 38 Avenue des Frères Montgolfier, 69680 Chassieu, France; (A.J.); (B.Q.); (A.C.); (J.-B.E.); (O.A.)
- Correspondence:
| |
Collapse
|
46
|
Crook B, Willerton L, Smith D, Wilson L, Poran V, Helps J, McDermott P. Legionella risk in evaporative cooling systems and underlying causes of associated breaches in health and safety compliance. Int J Hyg Environ Health 2019; 224:113425. [PMID: 31978741 DOI: 10.1016/j.ijheh.2019.113425] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 11/25/2019] [Accepted: 11/25/2019] [Indexed: 10/25/2022]
Abstract
Legionella bacteria can colonise and proliferate in water systems in the built environment and can be spread by aerosol generation. If inhaled by a susceptible individual, this can lead to respiratory infections such as Legionnaires' Disease (LD), or the generally milder Pontiac fever. Evaporative cooling systems (ECS), including cooling towers, used in industrial processes to dissipate excessive heat are prone to contamination by Legionella. From these systems it is possible for contaminated aerosols to be dispersed over a wide area, potentially exposing workers on site, neighbouring workplaces or nearby members of the public. Analysis of reported data on outbreaks of LD in Great Britain, collated for a ten year period, identified 44 separate legionellosis outbreaks of which seven were attributed to ECS and were responsible for 229 infections and 10 fatalities. This prompted an examination of health and safety inspection records which revealed, over a five year period, 321 enforcement actions taken against failings in Legionella control, of which 31% were attributed to cooling towers. Based on this evidence, an intervention programme was undertaken by health and safety inspectors in which 1,906 sites with ECS were inspected. During these inspections, sites were rated against four topics that are used to demonstrate compliance with statutory requirements for Legionella control: Risk Assessment; Written Control Scheme; Implementation of Control Scheme; and Record Keeping. While there was compliance at the majority of sites, breaches of the legislation were found at 625 sites (33% of those inspected), leading to 409 Improvement Notices (compelling dutyholders to make improvements to health and safety breaches of law in a given timeframe) and 12 Prohibition Notices (compelling dutyholders to stop work until they have remedied breaches in health and safety law) being served at 229 sites (12.0% of those inspected). Data from the intervention programme was analysed to identify root causes of these breaches of legislation on Legionella control. The majority of Improvement Notices (53%) were issued for the 'lack of effective implementation of a Written Control Scheme', with 'Risk Assessment' and 'Written Control Scheme' both accounting for 23%. More detailed examination showed major problems to be lack of training; failure to maintain the cleanliness of cooling towers and the water within them; risk assessments either being absent or not up to date, i.e., no longer representing the risks present; and Written Control Schemes being absent or insufficiently detailed. This provides a valuable data resource for dutyholders, so that they can understand where they need to focus to achieve significant improvement in legal compliance and therefore reduce the risk of LD for employees and members of the public affected by their workplace, and valuable data for regulators to target future interventions aimed at improving dutyholder compliance leading to better protection of workers and members of the public.
Collapse
Affiliation(s)
- Brian Crook
- Health and Safety Executive, Buxton, SK17 9JN, UK.
| | | | - Duncan Smith
- Health and Safety Executive, Newcastle, NE98 1YX, UK.
| | - Lee Wilson
- Health and Safety Executive, Liverpool, L20 7HS, UK.
| | - Vin Poran
- Health and Safety Executive, Leeds, LS11 9AT, UK.
| | - Julie Helps
- Health and Safety Executive, Cardiff, CF14 5SH, UK.
| | | |
Collapse
|
47
|
Hasni I, Chelkha N, Baptiste E, Mameri MR, Lachuer J, Plasson F, Colson P, La Scola B. Investigation of potential pathogenicity of Willaertia magna by investigating the transfer of bacteria pathogenicity genes into its genome. Sci Rep 2019; 9:18318. [PMID: 31797948 PMCID: PMC6892926 DOI: 10.1038/s41598-019-54580-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 11/10/2019] [Indexed: 12/14/2022] Open
Abstract
Willaertia magna c2c maky is a thermophilic amoeba closely related to the genus Naegleria. This free-living amoeba has the ability to eliminate Legionella pneumophila, which is an amoeba-resisting bacterium living in an aquatic environment. To prevent the proliferation of L. pneumophila in cooling towers, the use of W. magna as natural biocide has been proposed. To provide a better understanding of the W. magna genome, whole-genome sequencing was performed through the study of virulence factors and lateral gene transfers. This amoeba harbors a genome of 36.5 megabases with 18,519 predicted genes. BLASTp analyses reported protein homology between 136 W. magna sequences and amoeba-resistant microorganisms. Horizontal gene transfers were observed based on the basis of the phylogenetic reconstruction hypothesis. We detected 15 homologs of N. fowleri genes related to virulence, although these latter were also found in the genome of N. gruberi, which is a non-pathogenic amoeba. Furthermore, the cytotoxicity test performed on human cells supports the hypothesis that the strain c2c maky is a non-pathogenic amoeba. This work explores the genomic repertory for the first draft genome of genus Willaertia and provides genomic data for further comparative studies on virulence of related pathogenic amoeba, N. fowleri.
Collapse
Affiliation(s)
- Issam Hasni
- Aix-Marseille Université UM63, Institut de Recherche pour le Développement IRD 198, Assistance Publique - Hôpitaux de Marseille (AP-HM), Microbes, Evolution, Phylogeny and Infection (MEΦI), Institut Hospitalo-Universitaire (IHU) - Méditerranée Infection, Marseille, France.,Amoéba, Chassieu, France
| | - Nisrine Chelkha
- Aix-Marseille Université UM63, Institut de Recherche pour le Développement IRD 198, Assistance Publique - Hôpitaux de Marseille (AP-HM), Microbes, Evolution, Phylogeny and Infection (MEΦI), Institut Hospitalo-Universitaire (IHU) - Méditerranée Infection, Marseille, France
| | - Emeline Baptiste
- Aix-Marseille Université UM63, Institut de Recherche pour le Développement IRD 198, Assistance Publique - Hôpitaux de Marseille (AP-HM), Microbes, Evolution, Phylogeny and Infection (MEΦI), Institut Hospitalo-Universitaire (IHU) - Méditerranée Infection, Marseille, France
| | | | - Joel Lachuer
- ProfileXpert/Viroscan3D, UCBL UMS 3453 CNRS - US7 INSERM, Lyon, France.,Inserm U1052, CNRS UMR5286, Centre de Recherche en Cancérologie de Lyon, Lyon, France.,Université de Lyon, Lyon, France
| | | | - Philippe Colson
- Aix-Marseille Université UM63, Institut de Recherche pour le Développement IRD 198, Assistance Publique - Hôpitaux de Marseille (AP-HM), Microbes, Evolution, Phylogeny and Infection (MEΦI), Institut Hospitalo-Universitaire (IHU) - Méditerranée Infection, Marseille, France
| | - Bernard La Scola
- Aix-Marseille Université UM63, Institut de Recherche pour le Développement IRD 198, Assistance Publique - Hôpitaux de Marseille (AP-HM), Microbes, Evolution, Phylogeny and Infection (MEΦI), Institut Hospitalo-Universitaire (IHU) - Méditerranée Infection, Marseille, France.
| |
Collapse
|
48
|
|
49
|
Environmental surveillance and spatio-temporal analysis of Legionella spp. in a region of northeastern Italy (2002-2017). PLoS One 2019; 14:e0218687. [PMID: 31287819 PMCID: PMC6615612 DOI: 10.1371/journal.pone.0218687] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 06/06/2019] [Indexed: 01/01/2023] Open
Abstract
Legionella spp. are considered an important cause of potentially preventable morbidity and mortality, making environmental surveillance a crucial component of risk assessment plans. In this work, 20,319 water samples were collected in 3,983 environmental surveys during a 16-year period by ARPA, the Regional Agency for Environmental Protection, Friuli Venezia Giulia, and the results were studied to better understand the diffusion mechanisms of Legionella. The data showed a strong seasonal signal, a prevalence of L. pneumophila serogroup 2–15 in most environments (63% of positive samples), a prevalence of L. pneumophila serogroup 1 in swimming pool-associated environments (82% of positive samples), a persistent presence of Legionella in hospitals and a recurrent presence of Legionella in other facilities such as hotels, possibly years after interventions, highlighting the difficulty of eradicating the bacteria. Retrospective spatio-temporal analyses on geocoded historical data were carried out with SaTScan using an ordinal model with risk as a covariate to identify potential clusters with an excess of cases in the higher-risk categories. Although no outbreaks occurred during the period of study, such analyses identified spatially restricted zones with unusual contamination, which sometimes were also areas in which several surveys triggered by notifications of clinical cases were performed. Simulations of periodic prospective analyses permitted the assessment of the efficacy of the method in early detection of such clusters. The proposed method may be a useful tool in environmental surveillance, prevention and control of Legionella.
Collapse
|
50
|
Attenuated Legionella pneumophila Survives for a Long Period in an Environmental Water Site. BIOMED RESEARCH INTERNATIONAL 2019; 2019:8601346. [PMID: 31355284 PMCID: PMC6636516 DOI: 10.1155/2019/8601346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 06/05/2019] [Accepted: 06/16/2019] [Indexed: 01/25/2023]
Abstract
Legionella pneumophila is known as a human pathogen and is ubiquitous in natural and artificial aquatic environments. Many studies have revealed the virulence traits of L. pneumophila using clinical strains and a number of studies for characterizing environmental strains are also reported. However, the association between the virulence and survivability in the environment is unclear. In the present study, L. pneumophila was isolated from environmental water sites (Ashiyu foot spa, water fountain, and public bath), and the serogroups of isolated strains were determined by serological tests. Isolated strains were found to belong to serogroups SG1, SG2, SG3, SG4, SG5, SG8, SG9, and SG13. Untypeable strains were also obtained. Isolated strains were used for intracellular growth assay in a human monocytic cell line, THP-1. Among these strains, only an untypeable strain, named AY3, failed to replicate in THP-1. In addition, AY3 was maintained for a long period in an environmental water site, Ashiyu foot spa 2. Further, we compared the characteristics of several strains isolated from Ashiyu foot spa 2 and a clinical strain, Togus-1. AY3 failed to replicate in THP-1 cells but replicated in an amoeba model, Dictyostelium discoideum. Compared with Togus-1, the culturable cell number of environmental strains under stress conditions was higher. Moreover, biofilm formation was assessed, and AY3 showed the same degree of biofilm formation as Togus-1. Biofilm formation, replication in amoebae, and resistance against stress factors would explain the predominance of AY3 at one environmental site. Although the mechanism underlying the difference in the ability of AY3 to replicate in THP-1 cells or amoebae is still unclear, AY3 may abandon the ability to replicate in THP-1 cells to survive in one environment for a long period. Understanding the mechanisms of L. pneumophila in replication within different hosts should help in the control of Legionnaires' disease, but further study is necessary.
Collapse
|