1
|
Nolta NF, Christensen MB, Tresco PA. Advanced age is not a barrier to chronic intracortical single-unit recording in rat cortex. Front Neurosci 2024; 18:1389556. [PMID: 38817909 PMCID: PMC11138162 DOI: 10.3389/fnins.2024.1389556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 05/02/2024] [Indexed: 06/01/2024] Open
Abstract
Introduction Available evidence suggests that as we age, our brain and immune system undergo changes that increase our susceptibility to injury, inflammation, and neurodegeneration. Since a significant portion of the potential patients treated with a microelectrode-based implant may be older, it is important to understand the recording performance of such devices in an aged population. Methods We studied the chronic recording performance and the foreign body response (FBR) to a clinically used microelectrode array implanted in the cortex of 18-month-old Sprague Dawley rats. Results and discussion To the best of our knowledge, this is the first preclinical study of its type in the older mammalian brain. Here, we show that single-unit recording performance was initially robust then gradually declined over a 12-week period, similar to what has been previously reported using younger adult rats and in clinical trials. In addition, we show that FBR biomarker distribution was similar to what has been previously described for younger adult rats implanted with multi-shank recording arrays in the motor cortex. Using a quantitative immunohistochemcal approach, we observed that the extent of astrogliosis and tissue loss near the recording zone was inversely related to recording performance. A comparison of recording performance with a younger cohort supports the notion that aging, in and of itself, is not a limiting factor for the clinical use of penetrating microelectrode recording arrays for the treatment of certain CNS disorders.
Collapse
Affiliation(s)
- Nicholas F. Nolta
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| | - Michael B. Christensen
- Division of Urology, Department of Surgery, University of Utah School of Medicine, Salt Lake City, UT, United States
- Department of Otolaryngology – Head & Neck Surgery, University of Utah School of Medicine, Salt Lake City, UT, United States
| | - Patrick A. Tresco
- Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States
| |
Collapse
|
2
|
Boulingre M, Portillo-Lara R, Green RA. Biohybrid neural interfaces: improving the biological integration of neural implants. Chem Commun (Camb) 2023; 59:14745-14758. [PMID: 37991846 PMCID: PMC10720954 DOI: 10.1039/d3cc05006h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 11/10/2023] [Indexed: 11/24/2023]
Abstract
Implantable neural interfaces (NIs) have emerged in the clinic as outstanding tools for the management of a variety of neurological conditions caused by trauma or disease. However, the foreign body reaction triggered upon implantation remains one of the major challenges hindering the safety and longevity of NIs. The integration of tools and principles from biomaterial design and tissue engineering has been investigated as a promising strategy to develop NIs with enhanced functionality and performance. In this Feature Article, we highlight the main bioengineering approaches for the development of biohybrid NIs with an emphasis on relevant device design criteria. Technical and scientific challenges associated with the fabrication and functional assessment of technologies composed of both artificial and biological components are discussed. Lastly, we provide future perspectives related to engineering, regulatory, and neuroethical challenges to be addressed towards the realisation of the promise of biohybrid neurotechnology.
Collapse
Affiliation(s)
- Marjolaine Boulingre
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| | - Roberto Portillo-Lara
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| | - Rylie A Green
- Department of Bioengineering, Imperial College London, South Kensington, London, SW7 2AZ, UK
| |
Collapse
|
3
|
Rouzitalab A, Boulay CB, Park J, Sachs AJ. Intracortical brain-computer interfaces in primates: a review and outlook. Biomed Eng Lett 2023; 13:375-390. [PMID: 37519868 PMCID: PMC10382423 DOI: 10.1007/s13534-023-00286-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 05/04/2023] [Accepted: 05/14/2023] [Indexed: 08/01/2023] Open
Abstract
Brain-computer interfaces (BCI) translate brain signals into artificial output to restore or replace natural central nervous system (CNS) functions. Multiple processes, including sensorimotor integration, decision-making, motor planning, execution, and updating, are involved in any movement. For example, a BCI may be better able to restore naturalistic motor behaviors if it uses signals from multiple brain areas and decodes natural behaviors' cognitive and motor aspects. This review provides an overview of the preliminary information necessary to plan a BCI project focusing on intracortical implants in primates. Since the brain structure and areas of non-human primates (NHP) are similar to humans, exploring the result of NHP studies will eventually benefit human BCI studies. The different types of BCI systems based on the target cortical area, types of signals, and decoding methods will be discussed. In addition, various successful state-of-the-art cases will be reviewed in more detail, focusing on the general algorithm followed in the real-time system. Finally, an outlook for improving the current BCI research studies will be debated.
Collapse
Affiliation(s)
- Alireza Rouzitalab
- School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON K1N 6N5 Canada
- The Ottawa Hospital Research Institute, Ottawa, ON Canada
| | | | - Jeongwon Park
- School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON K1N 6N5 Canada
- Department of Electrical and Biomedical Engineering, University of Nevada, Reno, NV 89557 USA
| | - Adam J. Sachs
- The Ottawa Hospital Research Institute, Ottawa, ON Canada
- The University of Ottawa Brain and Mind Research Institute, Ottawa, ON Canada
- Division of Neurosurgery, Department of Surgery, The Ottawa Hospital, Ottawa, ON Canada
| |
Collapse
|
4
|
Shen K, Chen O, Edmunds JL, Piech DK, Maharbiz MM. Translational opportunities and challenges of invasive electrodes for neural interfaces. Nat Biomed Eng 2023; 7:424-442. [PMID: 37081142 DOI: 10.1038/s41551-023-01021-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 02/15/2023] [Indexed: 04/22/2023]
Abstract
Invasive brain-machine interfaces can restore motor, sensory and cognitive functions. However, their clinical adoption has been hindered by the surgical risk of implantation and by suboptimal long-term reliability. In this Review, we highlight the opportunities and challenges of invasive technology for clinically relevant electrophysiology. Specifically, we discuss the characteristics of neural probes that are most likely to facilitate the clinical translation of invasive neural interfaces, describe the neural signals that can be acquired or produced by intracranial electrodes, the abiotic and biotic factors that contribute to their failure, and emerging neural-interface architectures.
Collapse
Affiliation(s)
- Konlin Shen
- University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, Berkeley, CA, USA.
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA, USA.
| | - Oliver Chen
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
| | - Jordan L Edmunds
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
| | - David K Piech
- University of California, Berkeley - University of California, San Francisco Graduate Program in Bioengineering, Berkeley, CA, USA
| | - Michel M Maharbiz
- Department of Electrical Engineering and Computer Science, University of California, Berkeley, CA, USA
- Department of Bioengineering, University of California, Berkeley, CA, USA
- Chan-Zuckerberg Biohub, San Francisco, CA, USA
| |
Collapse
|
5
|
Frenzel J, Kupferer A, Zink M, Mayr SG. Laminin Adsorption and Adhesion of Neurons and Glial Cells on Carbon Implanted Titania Nanotube Scaffolds for Neural Implant Applications. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:3858. [PMID: 36364633 PMCID: PMC9656521 DOI: 10.3390/nano12213858] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/17/2022] [Accepted: 10/28/2022] [Indexed: 06/16/2023]
Abstract
Interfacing neurons persistently to conductive matter constitutes one of the key challenges when designing brain-machine interfaces such as neuroelectrodes or retinal implants. Novel materials approaches that prevent occurrence of loss of long-term adhesion, rejection reactions, and glial scarring are highly desirable. Ion doped titania nanotube scaffolds are a promising material to fulfill all these requirements while revealing sufficient electrical conductivity, and are scrutinized in the present study regarding their neuron-material interface. Adsorption of laminin, an essential extracellular matrix protein of the brain, is comprehensively analyzed. The implantation-dependent decline in laminin adsorption is revealed by employing surface characteristics such as nanotube diameter, ζ-potential, and surface free energy. Moreover, the viability of U87-MG glial cells and SH-SY5Y neurons after one and four days are investigated, as well as the material's cytotoxicity. The higher conductivity related to carbon implantation does not affect the viability of neurons, although it impedes glial cell proliferation. This gives rise to novel titania nanotube based implant materials with long-term stability, and could reduce undesirable glial scarring.
Collapse
Affiliation(s)
- Jan Frenzel
- Leibniz Institute of Surface Engineering (IOM), 04318 Leipzig, Germany
- Division of Surface Physics, Faculty of Physics and Earth Sciences, Leipzig University, 04103 Leipzig, Germany
- Research Group Biotechnology and Biomedicine, Faculty of Physics and Earth Sciences, Leipzig University, 04103 Leipzig, Germany
| | - Astrid Kupferer
- Leibniz Institute of Surface Engineering (IOM), 04318 Leipzig, Germany
- Division of Surface Physics, Faculty of Physics and Earth Sciences, Leipzig University, 04103 Leipzig, Germany
| | - Mareike Zink
- Research Group Biotechnology and Biomedicine, Faculty of Physics and Earth Sciences, Leipzig University, 04103 Leipzig, Germany
| | - Stefan G. Mayr
- Leibniz Institute of Surface Engineering (IOM), 04318 Leipzig, Germany
- Division of Surface Physics, Faculty of Physics and Earth Sciences, Leipzig University, 04103 Leipzig, Germany
| |
Collapse
|
6
|
Kim HJ, Ho JS. Wireless interfaces for brain neurotechnologies. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210020. [PMID: 35658679 DOI: 10.1098/rsta.2021.0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/13/2021] [Indexed: 06/15/2023]
Abstract
Wireless interfaces enable brain-implanted devices to remotely interact with the external world. They are critical components in modern research and clinical neurotechnologies and play a central role in determining their overall size, lifetime and functionality. Wireless interfaces use a wide range of modalities-including radio-frequency fields, acoustic waves and light-to transfer energy and data to and from an implanted device. These forms of energy interact with living tissue through distinct mechanisms and therefore lead to systems with vastly different form factors, operating characteristics, and safety considerations. This paper reviews recent advances in the development of wireless interfaces for brain neurotechnologies. We summarize the requirements that state-of-the-art brain-implanted devices impose on the wireless interface, and discuss the working principles and applications of wireless interfaces based on each modality. We also investigate challenges associated with wireless brain neurotechnologies and discuss emerging solutions permitted by recent developments in electrical engineering and materials science. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Han-Joon Kim
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
| | - John S Ho
- Department of Electrical and Computer Engineering National University of Singapore, Queenstown, Singapore
- The N.1 Institute for Health National University of Singapore, Queenstown, Singapore
- Institute for Health Innovation and Technology, National University of Singapore, Queenstown, Singapore
| |
Collapse
|
7
|
Khan ZM, Wilts E, Vlaisavljevich E, Long TE, Verbridge SS. Electroresponsive Hydrogels for Therapeutic Applications in the Brain. Macromol Biosci 2021; 22:e2100355. [PMID: 34800348 DOI: 10.1002/mabi.202100355] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/29/2021] [Indexed: 12/22/2022]
Abstract
Electroresponsive hydrogels possess a conducting material component and respond to electric stimulation through reversible absorption and expulsion of water. The high level of hydration, soft elastomeric compliance, biocompatibility, and enhanced electrochemical properties render these hydrogels suitable for implantation in the brain to enhance the transmission of neural electric signals and ion transport. This review provides an overview of critical electroresponsive hydrogel properties for augmenting electric stimulation in the brain. A background on electric stimulation in the brain through electroresponsive hydrogels is provided. Common conducting materials and general techniques to integrate them into hydrogels are briefly discussed. This review focuses on and summarizes advances in electric stimulation of electroconductive hydrogels for therapeutic applications in the brain, such as for controlling delivery of drugs, directing neural stem cell differentiation and neurogenesis, improving neural biosensor capabilities, and enhancing neural electrode-tissue interfaces. The key challenges in each of these applications are discussed and recommendations for future research are also provided.
Collapse
Affiliation(s)
- Zerin M Khan
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Emily Wilts
- Department of Cellular and Physiological Sciences, University of British Columbia, Vancouver, British Columbia, V6T 1Z3, Canada
| | - Eli Vlaisavljevich
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Timothy E Long
- Biodesign Center for Sustainable Macromolecular Materials and Manufacturing, Arizona State University, Tempe, AZ, 85287, USA
| | - Scott S Verbridge
- Virginia Tech - Wake Forest University School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
8
|
Woods GA, Rommelfanger NJ, Hong G. Bioinspired Materials for In Vivo Bioelectronic Neural Interfaces. MATTER 2020; 3:1087-1113. [PMID: 33103115 PMCID: PMC7583599 DOI: 10.1016/j.matt.2020.08.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The success of in vivo neural interfaces relies on their long-term stability and large scale in interrogating and manipulating neural activity after implantation. Conventional neural probes, owing to their limited spatiotemporal resolution and scale, face challenges for studying the massive, interconnected neural network in its native state. In this review, we argue that taking inspiration from biology will unlock the next generation of in vivo bioelectronic neural interfaces. Reducing the feature sizes of bioelectronic neural interfaces to mimic those of neurons enables high spatial resolution and multiplexity. Additionally, chronic stability at the device-tissue interface is realized by matching the mechanical properties of bioelectronic neural interfaces to those of the endogenous tissue. Further, modeling the design of neural interfaces after the endogenous topology of the neural circuitry enables new insights into the connectivity and dynamics of the brain. Lastly, functionalization of neural probe surfaces with coatings inspired by biology leads to enhanced tissue acceptance over extended timescales. Bioinspired neural interfaces will facilitate future developments in neuroscience studies and neurological treatments by leveraging bidirectional information transfer and integrating neuromorphic computing elements.
Collapse
Affiliation(s)
- Grace A. Woods
- Department of Applied Physics, Stanford University, Stanford, California, 94305, USA
- Wu Tsai Neurosciences Institute, Stanford University, Stanford, California, 94305, USA
| | - Nicholas J. Rommelfanger
- Department of Applied Physics, Stanford University, Stanford, California, 94305, USA
- Wu Tsai Neurosciences Institute, Stanford University, Stanford, California, 94305, USA
| | - Guosong Hong
- Department of Materials Science and Engineering, Stanford University, Stanford, California, 94305, USA
- Wu Tsai Neurosciences Institute, Stanford University, Stanford, California, 94305, USA
| |
Collapse
|
9
|
Gearing M, Kennedy P. Histological Confirmation of Myelinated Neural Filaments Within the Tip of the Neurotrophic Electrode After a Decade of Neural Recordings. Front Hum Neurosci 2020; 14:111. [PMID: 32372930 PMCID: PMC7187752 DOI: 10.3389/fnhum.2020.00111] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 03/11/2020] [Indexed: 11/13/2022] Open
Abstract
Aim Electrodes that provide brain to machine or computer interfacing must survive the lifetime of the person to be considered an acceptable prosthetic. The electrodes may be external such as with electroencephalographic (EEG), internal extracortical such as electrocorticographic (ECoG) or intracortical. Methods Most intracortical electrodes are placed close to the neuropil being recorded and do not survive years of recording. However, the Neurotrophic Electrode is placed within the cortex and the neuropil grows inside and through the hollow tip of the electrode and is thus trapped inside. Highly flexible coiled lead wires minimize the strain on the electrode tip. Histological analysis includes immunohistochemical detection of neurofilaments and the absence of gliosis. Results This configuration led to a decade long recording in this locked-in person. At year nine, the neural activity underwent conditioning experiments indicating that the neural activity was functional and not noise. This paper presents data on the histological analysis of the tissue inside the electrode tip after 13 years of implantation. Conclusion This paper is a singular example of histological analysis after a decade of recording. The histological analysis laid out herein is strong evidence that the brain can grow neurites into the electrode tip and record for a decade. This is profoundly important in the field of brain to machine or computer interfacing by implying that long term electrodes should incorporate some means of growing the neuropil into the electrode rather than placing the electrode into the neuropil.
Collapse
Affiliation(s)
- Marla Gearing
- Laboratory Medicine and Neurology, Department of Pathology, Emory University School of Medicine, Atlanta, GA, United States
| | | |
Collapse
|
10
|
Abstract
Locked-in syndrome (LIS) is characterized by an inability to move or speak in the presence of intact cognition and can be caused by brainstem trauma or neuromuscular disease. Quality of life (QoL) in LIS is strongly impaired by the inability to communicate, which cannot always be remedied by traditional augmentative and alternative communication (AAC) solutions if residual muscle activity is insufficient to control the AAC device. Brain-computer interfaces (BCIs) may offer a solution by employing the person's neural signals instead of relying on muscle activity. Here, we review the latest communication BCI research using noninvasive signal acquisition approaches (electroencephalography, functional magnetic resonance imaging, functional near-infrared spectroscopy) and subdural and intracortical implanted electrodes, and we discuss current efforts to translate research knowledge into usable BCI-enabled communication solutions that aim to improve the QoL of individuals with LIS.
Collapse
|
11
|
A review for the peripheral nerve interface designer. J Neurosci Methods 2019; 332:108523. [PMID: 31743684 DOI: 10.1016/j.jneumeth.2019.108523] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 11/14/2019] [Accepted: 11/15/2019] [Indexed: 12/11/2022]
Abstract
Informational density and relative accessibility of the peripheral nervous system make it an attractive site for therapeutic intervention. Electrode-based electrophysiological interfaces with peripheral nerves have been under development since the 1960s and, for several applications, have seen widespread clinical implementation. However, many applications require a combination of neural target resolution and stability which has thus far eluded existing peripheral nerve interfaces (PNIs). With the goal of aiding PNI designers in development of devices that meet the demands of next-generation applications, this review seeks to collect and present practical considerations and best practices which emerge from the literature, including both lessons learned during early PNI development and recent ideas. Fundamental and practical principles guiding PNI design are reviewed, followed by an updated and critical account of existing PNI designs and strategies. Finally, a brief survey of in vitro and in vivo PNI characterization methods is presented.
Collapse
|
12
|
Adewole DO, Serruya MD, Wolf JA, Cullen DK. Bioactive Neuroelectronic Interfaces. Front Neurosci 2019; 13:269. [PMID: 30983957 PMCID: PMC6449725 DOI: 10.3389/fnins.2019.00269] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 03/07/2019] [Indexed: 12/31/2022] Open
Abstract
Within the neural engineering field, next-generation implantable neuroelectronic interfaces are being developed using biologically-inspired and/or biologically-derived materials to improve upon the stability and functional lifetime of current interfaces. These technologies use biomaterials, bioactive molecules, living cells, or some combination of these, to promote host neuronal survival, reduce the foreign body response, and improve chronic device-tissue integration. This article provides a general overview of the different strategies, milestones, and evolution of bioactive neural interfaces including electrode material properties, biological coatings, and "decoration" with living cells. Another such biohybrid approach developed in our lab uses preformed implantable micro-tissue featuring long-projecting axonal tracts encased within carrier biomaterial micro-columns. These so-called "living electrodes" have been engineered with carefully tailored material, mechanical, and biological properties to enable natural, synaptic based modulation of specific host circuitry while ultimately being under computer control. This article provides an overview of these living electrodes, including design and fabrication, performance attributes, as well as findings to date characterizing in vitro and in vivo functionality.
Collapse
Affiliation(s)
- Dayo O. Adewole
- Center for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, United States
- Center for Neurotrauma, Neurodegeneration and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA, United States
| | - Mijail D. Serruya
- Department of Neurology, Thomas Jefferson University, Philadelphia, PA, United States
| | - John A. Wolf
- Center for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
- Center for Neurotrauma, Neurodegeneration and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA, United States
| | - D. Kacy Cullen
- Center for Brain Injury and Repair, Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, United States
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA, United States
- Center for Neurotrauma, Neurodegeneration and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA, United States
| |
Collapse
|
13
|
Wire Electrodes Embedded in Artificial Conduit for Long-term Monitoring of the Peripheral Nerve Signal. MICROMACHINES 2019; 10:mi10030184. [PMID: 30871203 PMCID: PMC6471311 DOI: 10.3390/mi10030184] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 03/07/2019] [Accepted: 03/08/2019] [Indexed: 01/05/2023]
Abstract
Massive efforts to develop neural interfaces have been made for controlling prosthetic limbs according to the will of the patient, with the ultimate goal being long-term implantation. One of the major struggles is that the electrode’s performance degrades over time due to scar formation. Herein, we have developed peripheral nerve electrodes with a cone-shaped flexible artificial conduit capable of protecting wire electrodes from scar formation. The wire electrodes, which are composed of biocompatible alloy materials, were embedded in the conduit where the inside was filled with collagen to allow the damaged nerves to regenerate into the conduit and interface with the wire electrodes. After implanting the wire electrodes into the sciatic nerve of a rat, we successfully recorded the peripheral neural signals while providing mechanical stimulation. Remarkably, we observed the external stimuli-induced nerve signals at 19 weeks after implantation. This is possibly due to axon regeneration inside our platform. To verify the tissue response of our electrodes to the sciatic nerve, we performed immunohistochemistry (IHC) and observed axon regeneration without scar tissue forming inside the conduit. Thus, our strategy has proven that our neural interface can play a significant role in the long-term monitoring of the peripheral nerve signal.
Collapse
|
14
|
Kearney E, Guenther FH. Articulating: The Neural Mechanisms of Speech Production. LANGUAGE, COGNITION AND NEUROSCIENCE 2019; 34:1214-1229. [PMID: 31777753 PMCID: PMC6880942 DOI: 10.1080/23273798.2019.1589541] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Accepted: 02/21/2019] [Indexed: 05/19/2023]
Abstract
Speech production is a highly complex sensorimotor task involving tightly coordinated processing across large expanses of the cerebral cortex. Historically, the study of the neural underpinnings of speech suffered from the lack of an animal model. The development of non-invasive structural and functional neuroimaging techniques in the late 20th century has dramatically improved our understanding of the speech network. Techniques for measuring regional cerebral blood flow have illuminated the neural regions involved in various aspects of speech, including feedforward and feedback control mechanisms. In parallel, we have designed, experimentally tested, and refined a neural network model detailing the neural computations performed by specific neuroanatomical regions during speech. Computer simulations of the model account for a wide range of experimental findings, including data on articulatory kinematics and brain activity during normal and perturbed speech. Furthermore, the model is being used to investigate a wide range of communication disorders.
Collapse
Affiliation(s)
- Elaine Kearney
- Department of Speech, Language, and Hearing Sciences, Boston University, 635 Commonwealth Avenue, Boston, MA 02215
| | - Frank H. Guenther
- Department of Speech, Language, and Hearing Sciences, Boston University, 635 Commonwealth Avenue, Boston, MA 02215
- Department of Biomedical Engineering, Boston University, 44 Cummington Street, Boston, MA 02215
- The Picower Institute for Learning and Memory, Massachusetts Institute of Technology, 43 Vassar Street, Cambridge, MA 02139
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 149 13th Street, Charlestown, MA 02129
| |
Collapse
|
15
|
Brandman DM, Cash SS, Hochberg LR. Review: Human Intracortical Recording and Neural Decoding for Brain-Computer Interfaces. IEEE Trans Neural Syst Rehabil Eng 2017; 25:1687-1696. [PMID: 28278476 PMCID: PMC5815832 DOI: 10.1109/tnsre.2017.2677443] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Brain-computer interfaces (BCIs) use neural information recorded from the brain for the voluntary control of external devices. The development of BCI systems has largely focused on improving functional independence for individuals with severe motor impairments, including providing tools for communication and mobility. In this review, we describe recent advances in intracortical BCI technology and provide potential directions for further research.
Collapse
|
16
|
Lebedev MA, Nicolelis MAL. Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation. Physiol Rev 2017; 97:767-837. [PMID: 28275048 DOI: 10.1152/physrev.00027.2016] [Citation(s) in RCA: 235] [Impact Index Per Article: 33.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Brain-machine interfaces (BMIs) combine methods, approaches, and concepts derived from neurophysiology, computer science, and engineering in an effort to establish real-time bidirectional links between living brains and artificial actuators. Although theoretical propositions and some proof of concept experiments on directly linking the brains with machines date back to the early 1960s, BMI research only took off in earnest at the end of the 1990s, when this approach became intimately linked to new neurophysiological methods for sampling large-scale brain activity. The classic goals of BMIs are 1) to unveil and utilize principles of operation and plastic properties of the distributed and dynamic circuits of the brain and 2) to create new therapies to restore mobility and sensations to severely disabled patients. Over the past decade, a wide range of BMI applications have emerged, which considerably expanded these original goals. BMI studies have shown neural control over the movements of robotic and virtual actuators that enact both upper and lower limb functions. Furthermore, BMIs have also incorporated ways to deliver sensory feedback, generated from external actuators, back to the brain. BMI research has been at the forefront of many neurophysiological discoveries, including the demonstration that, through continuous use, artificial tools can be assimilated by the primate brain's body schema. Work on BMIs has also led to the introduction of novel neurorehabilitation strategies. As a result of these efforts, long-term continuous BMI use has been recently implicated with the induction of partial neurological recovery in spinal cord injury patients.
Collapse
|
17
|
Sahyouni R, Chang DT, Moshtaghi O, Mahmoodi A, Djalilian HR, Lin HW. Functional and Histological Effects of Chronic Neural Electrode Implantation. Laryngoscope Investig Otolaryngol 2017; 2:80-93. [PMID: 28894826 PMCID: PMC5527370 DOI: 10.1002/lio2.66] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/20/2016] [Indexed: 12/27/2022] Open
Abstract
Objectives Permanent injury to the cranial nerves can often result in a substantial reduction in quality of life. Novel and innovative interventions can help restore form and function in nerve paralysis, with bioelectric interfaces among the more promising of these approaches. The foreign body response is an important consideration for any bioelectric device as it influences the function and effectiveness of the implant. The purpose of this review is to describe tissue and functional effects of chronic neural implantation among the different categories of neural implants and highlight advances in peripheral and cranial nerve stimulation. Data Sources: PubMed, IEEE, and Web of Science literature search. Review Methods: A review of the current literature was conducted to examine functional and histologic effects of bioelectric interfaces for neural implants. Results Bioelectric devices can be characterized as intraneural, epineural, perineural, intranuclear, or cortical depending on their placement relative to nerves and neuronal cell bodies. Such devices include nerve‐specific stimulators, neuroprosthetics, brainstem implants, and deep brain stimulators. Regardless of electrode location and interface type, acute and chronic histological, macroscopic and functional changes can occur as a result of both passive and active tissue responses to the bioelectric implant. Conclusion A variety of chronically implantable electrodes have been developed to treat disorders of the peripheral and cranial nerves, to varying degrees of efficacy. Consideration and mitigation of detrimental effects at the neural interface with further optimization of functional nerve stimulation will facilitate the development of these technologies and translation to the clinic. Level of Evidence 3.
Collapse
Affiliation(s)
- Ronald Sahyouni
- Department of Biomedical Engineering, University of California Irvine U.S.A
| | - David T Chang
- Department of Otolaryngology-Head & Neck Surgery, University of California Irvine U.S.A.,Division of Otolaryngology-Head &Neck Surgery, Irvine, California, Children's Hospital of Orange County Orange California U.S.A
| | - Omid Moshtaghi
- School of Medicine, University of California Irvine U.S.A
| | - Amin Mahmoodi
- Department of Biomedical Engineering, University of California Irvine U.S.A
| | - Hamid R Djalilian
- Department of Otolaryngology-Head & Neck Surgery, University of California Irvine U.S.A
| | - Harrison W Lin
- Department of Otolaryngology-Head & Neck Surgery, University of California Irvine U.S.A
| |
Collapse
|
18
|
Hara SA, Kim BJ, Kuo JTW, Lee CD, Meng E, Pikov V. Long-term stability of intracortical recordings using perforated and arrayed Parylene sheath electrodes. J Neural Eng 2016; 13:066020. [DOI: 10.1088/1741-2560/13/6/066020] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
19
|
Thompson CH, Zoratti MJ, Langhals NB, Purcell EK. Regenerative Electrode Interfaces for Neural Prostheses. TISSUE ENGINEERING PART B-REVIEWS 2016; 22:125-35. [DOI: 10.1089/ten.teb.2015.0279] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Cort H. Thompson
- Department of Electrical and Computer Engineering, Neuroscience Program, Michigan State University, East Lansing, Michigan
| | - Marissa J. Zoratti
- Department of Electrical and Computer Engineering, Neuroscience Program, Michigan State University, East Lansing, Michigan
| | - Nicholas B. Langhals
- Department of Electrical and Computer Engineering, Neuroscience Program, Michigan State University, East Lansing, Michigan
| | - Erin K. Purcell
- Department of Electrical and Computer Engineering, Neuroscience Program, Michigan State University, East Lansing, Michigan
| |
Collapse
|
20
|
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording. Med Biol Eng Comput 2016; 54:23-44. [PMID: 26753777 DOI: 10.1007/s11517-015-1430-4] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Accepted: 12/10/2015] [Indexed: 12/22/2022]
Abstract
Electrodes serve as the first critical interface to the biological organ system. In neuroprosthetic applications, for example, electrodes interface to the tissue for either signal recording or tissue stimulation. In this review, we consider electrodes for recording neural activity. Recording electrodes serve as wiretaps into the neural tissues, providing readouts of electrical activity. These signals give us valuable insights into the organization and functioning of the nervous system. The recording interfaces have also shown promise in aiding treatment of motor and sensory disabilities caused by neurological disorders. Recent advances in fabrication technology have generated wide interest in creating tiny, high-density electrode interfaces for neural tissues. An ideal electrode should be small enough and be able to achieve reliable and conformal integration with the structures of the nervous system. As a result, the existing electrode designs are being shrunk and packed to form small form factor interfaces to tissue. Here, an overview of the historic and state-of-the-art electrode technologies for recording neural activity is presented first with a focus on their development road map. The fact that the dimensions of recording electrode sites are being scaled down from micron to submicron scale to enable dense interfaces is appreciated. The current trends in recording electrode technologies are then reviewed. Current and future considerations in electrode design, including the use of inorganic nanostructures and biologically inspired or biocomapatible materials are discussed, along with an overview of the applications of flexible materials and transistor transduction schemes. Finally, we detail the major technical challenges facing chronic use of reliable recording electrode technology.
Collapse
|
21
|
Abstract
Single neuron actions and interactions are the sine qua non of brain function, and nearly all diseases and injuries of the CNS trace their clinical sequelae to neuronal dysfunction or failure. Remarkably, discussion of neuronal activity is largely absent in clinical neuroscience. Advances in neurotechnology and computational capabilities, accompanied by shifts in theoretical frameworks, have led to renewed interest in the information represented by single neurons. Using direct interfaces with the nervous system, millisecond-scale information will soon be extracted from single neurons in clinical environments, supporting personalized treatment of neurologic and psychiatric disease. In this Perspective, we focus on single-neuronal activity in restoring communication and motor control in patients suffering from devastating neurological injuries. We also explore the single neuron's role in epilepsy and movement disorders, surgical anesthesia, and in cognitive processes disrupted in neurodegenerative and neuropsychiatric disease. Finally, we speculate on how technological advances will revolutionize neurotherapeutics.
Collapse
Affiliation(s)
- Sydney S Cash
- Neurotechnology Trials Unit, Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| | - Leigh R Hochberg
- Neurotechnology Trials Unit, Department of Neurology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA; School of Engineering and Institute for Brain Science, Brown University, Providence, RI 02912, USA; Center for Neurorestoration and Neurotechnology, Providence VA Medical Center, Providence, RI 02908, USA.
| |
Collapse
|
22
|
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing. Biomaterials 2015; 53:173-83. [DOI: 10.1016/j.biomaterials.2015.02.021] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Revised: 01/21/2015] [Accepted: 02/01/2015] [Indexed: 01/10/2023]
|
23
|
Lee CD, Hara SA, Yu L, Kuo JTW, Kim BJ, Hoang T, Pikov V, Meng E. Matrigel coatings for Parylene sheath neural probes. J Biomed Mater Res B Appl Biomater 2015; 104:357-68. [PMID: 25809504 DOI: 10.1002/jbm.b.33390] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 12/26/2014] [Accepted: 01/29/2015] [Indexed: 01/15/2023]
Abstract
The biologically derived hydrogel Matrigel (MG) was used to coat a Parylene-based sheath intracortical electrode to act as a mechanical and biological buffer as well as a matrix for delivering bioactive molecules to modulate the cellular response and improve recording quality. MG was loaded with dexamethasone to reduce the immune response together with nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF) to maintain neuronal density and encourage neuronal ingrowth toward electrodes within the sheath. Coating the Parylene sheath electrode with the loaded MG significantly improved the signal-to-noise ratio for neural events recorded from the motor cortex in rat for more than 3 months. Electron microscopy showed even coverage of both the Parylene substrate and the platinum recording electrodes. Electrochemical impedance spectroscopy (EIS) of coated electrodes in 1× phosphate-buffered saline demonstrated low impedance required for recording neural signals. This result was confirmed by in vivo EIS data, showing significantly decreased impedance during the first week of recording. Dexamethasone, NGF, and BDNF loaded into MG were released within 1 day in 1× phosphate-buffered saline. Although previous studies showed that MG loaded with either the immunosuppressant or the neurotrophic factor cocktail provided modest improvement in recording quality in a 1-month in vivo study, the combination of these bioactive molecules did not improve the signal quality over coating probes with only MG in a 3-month in vivo study. The MG coating may further improve recording quality by optimizing the in vivo release profile for the bioactive molecules.
Collapse
Affiliation(s)
- Curtis D Lee
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Seth A Hara
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Lawrence Yu
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Jonathan T W Kuo
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Brian J Kim
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Tuan Hoang
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111
| | - Victor Pikov
- Neural Engineering Program, Huntington Medical Research Institutes, Pasadena, California, 91105-3104
| | - Ellis Meng
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, 90089-1111.,Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, California, 90089-2560
| |
Collapse
|
24
|
Gunasekera B, Saxena T, Bellamkonda R, Karumbaiah L. Intracortical recording interfaces: current challenges to chronic recording function. ACS Chem Neurosci 2015; 6:68-83. [PMID: 25587704 DOI: 10.1021/cn5002864] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Brain Computer Interfaces (BCIs) offer significant hope to tetraplegic and paraplegic individuals. This technology relies on extracting and translating motor intent to facilitate control of a computer cursor or to enable fine control of an external assistive device such as a prosthetic limb. Intracortical recording interfaces (IRIs) are critical components of BCIs and consist of arrays of penetrating electrodes that are implanted into the motor cortex of the brain. These multielectrode arrays (MEAs) are responsible for recording and conducting neural signals from local ensembles of neurons in the motor cortex with the high speed and spatiotemporal resolution that is required for exercising control of external assistive prostheses. Recent design and technological innovations in the field have led to significant improvements in BCI function. However, long-term (chronic) BCI function is severely compromised by short-term (acute) IRI recording failure. In this review, we will discuss the design and function of current IRIs. We will also review a host of recent advances that contribute significantly to our overall understanding of the cellular and molecular events that lead to acute recording failure of these invasive implants. We will also present recent improvements to IRI design and provide insights into the futuristic design of more chronically functional IRIs.
Collapse
Affiliation(s)
- Bhagya Gunasekera
- Regenerative
Bioscience Center, ADS Complex, The University of Georgia, Athens, Georgia 30602-2771, United States
| | - Tarun Saxena
- Wallace
H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, United States
| | - Ravi Bellamkonda
- Wallace
H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, United States
| | - Lohitash Karumbaiah
- Regenerative
Bioscience Center, ADS Complex, The University of Georgia, Athens, Georgia 30602-2771, United States
| |
Collapse
|
25
|
Multifunctional fibers for simultaneous optical, electrical and chemical interrogation of neural circuits in vivo. Nat Biotechnol 2015; 33:277-84. [PMID: 25599177 DOI: 10.1038/nbt.3093] [Citation(s) in RCA: 338] [Impact Index Per Article: 37.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2014] [Accepted: 11/10/2014] [Indexed: 12/19/2022]
Abstract
Brain function depends on simultaneous electrical, chemical and mechanical signaling at the cellular level. This multiplicity has confounded efforts to simultaneously measure or modulate these diverse signals in vivo. Here we present fiber probes that allow for simultaneous optical stimulation, neural recording and drug delivery in behaving mice with high resolution. These fibers are fabricated from polymers by means of a thermal drawing process that allows for the integration of multiple materials and interrogation modalities into neural probes. Mechanical, electrical, optical and microfluidic measurements revealed high flexibility and functionality of the probes under bending deformation. Long-term in vivo recordings, optogenetic stimulation, drug perturbation and analysis of tissue response confirmed that our probes can form stable brain-machine interfaces for at least 2 months. We expect that our multifunctional fibers will permit more detailed manipulation and analysis of neural circuits deep in the brain of behaving animals than achievable before.
Collapse
|
26
|
Jorfi M, Skousen JL, Weder C, Capadona JR. Progress towards biocompatible intracortical microelectrodes for neural interfacing applications. J Neural Eng 2014; 12:011001. [PMID: 25460808 DOI: 10.1088/1741-2560/12/1/011001] [Citation(s) in RCA: 218] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Collapse
Affiliation(s)
- Mehdi Jorfi
- Adolphe Merkle Institute, University of Fribourg, Rte de l'Ancienne Papeterie, CH-1723 Marly, Switzerland
| | | | | | | |
Collapse
|
27
|
Sohal HS, Jackson A, Jackson R, Clowry GJ, Vassilevski K, O'Neill A, Baker SN. The sinusoidal probe: a new approach to improve electrode longevity. FRONTIERS IN NEUROENGINEERING 2014; 7:10. [PMID: 24808859 PMCID: PMC4010751 DOI: 10.3389/fneng.2014.00010] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2013] [Accepted: 04/07/2014] [Indexed: 11/13/2022]
Abstract
Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive brain-machine interfaces. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We have designed a sinusoidal probe in order to reduce movement of the recording tip relative to the surrounding neural tissue. The probe was microfabricated from flexible materials and incorporated a sinusoidal shaft to minimize tethering forces and a 3D spheroid tip to anchor the recording site within the brain. Compared to standard microwire electrodes, the signal-to-noise ratio and local field potential power of sinusoidal probe recordings from rabbits was more stable across recording periods up to 678 days. Histological quantification of microglia and astrocytes showed reduced neuronal tissue damage especially for the tip region between 6 and 24 months post-implantation. We suggest that the micromotion-reducing measures incorporated into our design, at least partially, decreased the magnitude of gliosis, resulting in enhanced longevity of recording.
Collapse
Affiliation(s)
- Harbaljit S Sohal
- Newcastle Movement Lab, Institute of Neuroscience, Newcastle University Newcastle Upon Tyne, UK ; School of Electrical and Electronic Engineering, Newcastle University Newcastle Upon Tyne, UK
| | - Andrew Jackson
- Newcastle Movement Lab, Institute of Neuroscience, Newcastle University Newcastle Upon Tyne, UK
| | - Richard Jackson
- School of Electrical and Electronic Engineering, Newcastle University Newcastle Upon Tyne, UK
| | - Gavin J Clowry
- Newcastle Movement Lab, Institute of Neuroscience, Newcastle University Newcastle Upon Tyne, UK
| | - Konstantin Vassilevski
- School of Electrical and Electronic Engineering, Newcastle University Newcastle Upon Tyne, UK
| | - Anthony O'Neill
- School of Electrical and Electronic Engineering, Newcastle University Newcastle Upon Tyne, UK
| | - Stuart N Baker
- Newcastle Movement Lab, Institute of Neuroscience, Newcastle University Newcastle Upon Tyne, UK
| |
Collapse
|
28
|
Abstract
The analysis of electrophysiological recordings often involves visual inspection of time series data to locate specific experiment epochs, mask artifacts, and verify the results of signal processing steps, such as filtering or spike detection. Long-term experiments with continuous data acquisition generate large amounts of data. Rapid browsing through these massive datasets poses a challenge to conventional data plotting software because the plotting time increases proportionately to the increase in the volume of data. This paper presents FTSPlot, which is a visualization concept for large-scale time series datasets using techniques from the field of high performance computer graphics, such as hierarchic level of detail and out-of-core data handling. In a preprocessing step, time series data, event, and interval annotations are converted into an optimized data format, which then permits fast, interactive visualization. The preprocessing step has a computational complexity of ; the visualization itself can be done with a complexity of and is therefore independent of the amount of data. A demonstration prototype has been implemented and benchmarks show that the technology is capable of displaying large amounts of time series data, event, and interval annotations lag-free with ms. The current 64-bit implementation theoretically supports datasets with up to bytes, on the x86_64 architecture currently up to bytes are supported, and benchmarks have been conducted with bytes/1 TiB or double precision samples. The presented software is freely available and can be included as a Qt GUI component in future software projects, providing a standard visualization method for long-term electrophysiological experiments.
Collapse
Affiliation(s)
- Michael Riss
- Department of ETSEIB, Technical University of Catalonia (UPC), Barcelona, Spain
- * E-mail:
| |
Collapse
|
29
|
Abstract
Development of neural prostheses over the past few decades has produced a number of clinically relevant brain-machine interfaces (BMIs), such as the cochlear prostheses and deep brain stimulators. Current research pursues the restoration of communication or motor function to individuals with neurological disorders. Efforts in the field, such as the BrainGate trials, have already demonstrated that such interfaces can enable humans to effectively control external devices with neural signals. However, a number of significant issues regarding BMI performance, device capabilities, and surgery must be resolved before clinical use of BMI technology can become widespread. This chapter reviews challenges to clinical translation and discusses potential solutions that have been reported in recent literature, with focuses on hardware reliability, state-of-the-art decoding algorithms, and surgical considerations during implantation.
Collapse
|
30
|
Kim BJ, Kuo JTW, Hara SA, Lee CD, Yu L, Gutierrez CA, Hoang TQ, Pikov V, Meng E. 3D Parylene sheath neural probe for chronic recordings. J Neural Eng 2013; 10:045002. [DOI: 10.1088/1741-2560/10/4/045002] [Citation(s) in RCA: 108] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
31
|
Kuo JTW, Kim BJ, Hara SA, Lee CD, Gutierrez CA, Hoang TQ, Meng E. Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration. LAB ON A CHIP 2013; 13:554-561. [PMID: 23160191 DOI: 10.1039/c2lc40935f] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A Parylene C neural probe with a three dimensional sheath structure was designed, fabricated, and characterized. Multiple platinum (Pt) electrodes for recording neural signals were fabricated on both inner and outer surfaces of the sheath structure. Thermoforming of Parylene was used to create the three dimensional sheath structures from flat surface micromachined microchannels using solid microwires as molds. Benchtop electrochemical characterization was performed on the thin film Pt electrodes using cyclic voltammetry and electrochemical impedance spectroscopy and showed that electrodes possessed low impedances suitable for neuronal recordings. A procedure for implantation of the neural probe was developed and successfully demonstrated in vitro into an agarose brain tissue model. The electrode-lined sheath will be decorated with eluting neurotrophic factors to promote in vivo neural tissue ingrowth post-implantation. These features will enhance tissue integration and improve recording quality towards realizing reliable chronic neural interfaces.
Collapse
Affiliation(s)
- Jonathan T W Kuo
- Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, DRB-140, Los Angeles, CA 90089-1111, USA
| | | | | | | | | | | | | |
Collapse
|
32
|
Kennedy P. Reliable neural interface: the first quarter century of the neurotrophic electrode. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:3332-3335. [PMID: 23366639 DOI: 10.1109/embc.2012.6346678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
For development of a long-term, reliable cortical recording electrode, animal and human data support the approach of trapping the brain inside the electrode.
Collapse
Affiliation(s)
- Phil Kennedy
- Neural Signals Inc., 3400 McClure Bridge Rd., Duluth, GA 30096, USA
| |
Collapse
|
33
|
Kennedy P. Changes in emotional state modulate neuronal firing rates of human speech motor cortex: a case study in long-term recording. Neurocase 2011; 17:381-93. [PMID: 21967282 PMCID: PMC3187572 DOI: 10.1080/13554794.2010.532137] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
In many brain areas, modulations in neuronal firing rates are thought to code information. However, in electrophysiological recording experiments, especially recordings in human patients, the type of information that is coded by a neuron's discharge patterns is often not known, or difficult to determine. From our long experience with chronic recordings in humans, we have come to suspect that such unexplained modulations in firing rates are often due to state changes in the subject. We here present two case studies, with extensive data in one subject to illustrate the point that a change in the subject's emotions, such as sudden fear, surprise, or happiness, may trigger substantial changes in firing rates.
Collapse
Affiliation(s)
- Philip Kennedy
- Neural Signals Inc., Suite D402, 3400 McClure Bridge Road, Duluth, GA 30096, USA.
| |
Collapse
|
34
|
Abstract
The ultimate goal of neuroscience research is to understand the operating mechanism of the human brain and to exploit this understanding to devise methods for repair when it malfunctions. A key feature of this operating mechanism is electrical activity of single brain cells and cell assemblies. For obvious ethical reasons, scientists rely mostly on animal research in the study of such signals. Research in humans is often limited to electrical signals that can be recorded at the scalp or to surrogates of electrical activity, namely magnetic source imaging and measures of regional blood flow and metabolism. Invasive brain recordings performed in patients during various clinical procedures provide a unique opportunity to record high-resolution signals in vivo from the human brain-data that are otherwise unavailable. Of special value are the rare opportunities to record in awake humans the activity of single brain cells and small cellular assemblies. These recordings provide a unique view on aspects of human cognition that are impossible to study in animals, including language, imagery, episodic memory, volition, and even consciousness. In the current review we discuss the unique contribution of invasive recordings from patients to the field of cognitive neuroscience.
Collapse
Affiliation(s)
- Roy Mukamel
- Department of Neurosurgery, David Geffen School of Medicine and Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles, 90095, USA.
| | | |
Collapse
|
35
|
Brumberg JS, Wright EJ, Andreasen DS, Guenther FH, Kennedy PR. Classification of intended phoneme production from chronic intracortical microelectrode recordings in speech-motor cortex. Front Neurosci 2011; 5:65. [PMID: 21629876 PMCID: PMC3096823 DOI: 10.3389/fnins.2011.00065] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2010] [Accepted: 04/24/2011] [Indexed: 11/30/2022] Open
Abstract
We conducted a neurophysiological study of attempted speech production in a paralyzed human volunteer using chronic microelectrode recordings. The volunteer suffers from locked-in syndrome leaving him in a state of near-total paralysis, though he maintains good cognition and sensation. In this study, we investigated the feasibility of supervised classification techniques for prediction of intended phoneme production in the absence of any overt movements including speech. Such classification or decoding ability has the potential to greatly improve the quality-of-life of many people who are otherwise unable to speak by providing a direct communicative link to the general community. We examined the performance of three classifiers on a multi-class discrimination problem in which the items were 38 American English phonemes including monophthong and diphthong vowels and consonants. The three classifiers differed in performance, but averaged between 16 and 21% overall accuracy (chance-level is 1/38 or 2.6%). Further, the distribution of phonemes classified statistically above chance was non-uniform though 20 of 38 phonemes were classified with statistical significance for all three classifiers. These preliminary results suggest supervised classification techniques are capable of performing large scale multi-class discrimination for attempted speech production and may provide the basis for future communication prostheses.
Collapse
Affiliation(s)
| | | | - Dinal S. Andreasen
- Neural Signals Inc. Duluth, GA, USA
- Georgia Tech Research InstituteMarietta, GA, USA
| | - Frank H. Guenther
- Department of Cognitive and Neural Systems, Boston UniversityBoston, MA, USA
- Department of Speech, Language, and Hearing Sciences, Boston UniversityBoston, MA, USA
- Division of Health Sciences and Technology, Harvard University–Massachusetts Institute of TechnologyCambridge, MA, USA
| | | |
Collapse
|
36
|
Brumberg JS, Guenther FH. Development of speech prostheses: current status and recent advances. Expert Rev Med Devices 2011; 7:667-79. [PMID: 20822389 DOI: 10.1586/erd.10.34] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Brain-computer interfaces (BCIs) have been developed over the past decade to restore communication to persons with severe paralysis. In the most severe cases of paralysis, known as locked-in syndrome, patients retain cognition and sensation, but are capable of only slight voluntary eye movements. For these patients, no standard communication method is available, although some can use BCIs to communicate by selecting letters or words on a computer. Recent research has sought to improve on existing techniques by using BCIs to create a direct prediction of speech utterances rather than to simply control a spelling device. Such methods are the first steps towards speech prostheses as they are intended to entirely replace the vocal apparatus of paralyzed users. This article outlines many well known methods for restoration of communication by BCI and illustrates the difference between spelling devices and direct speech prediction or speech prosthesis.
Collapse
Affiliation(s)
- Jonathan S Brumberg
- Department of Cognitive and Neural Systems, Boston University, Boston, MA 02215, USA.
| | | |
Collapse
|
37
|
Schouenborg J. Biocompatible multichannel electrodes for long-term neurophysiological studies and clinical therapy--novel concepts and design. PROGRESS IN BRAIN RESEARCH 2011; 194:61-70. [PMID: 21867794 DOI: 10.1016/b978-0-444-53815-4.00017-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Chronic neural interfaces that are both structurally and functionally stable inside the brain over long time periods and that have minimal effects on the physiological conditions of the neural tissue to be studied hold great promise to become invaluable research and clinical tool in the near future. In this chapter, I will briefly review the state of the art of neural interfaces and the concepts behind our recent research and development of ultrathin multichannel electrodes.
Collapse
Affiliation(s)
- Jens Schouenborg
- Neuronano Research Center, Experimental Medical Science and The Nanometer Consortium, Lund University, Lund, Sweden.
| |
Collapse
|
38
|
Kennedy P, Andreasen D, Bartels J, Ehirim P, Mao H, Velliste M, Wichmann T, Wright J. Making the lifetime connection between brain and machine for restoring and enhancing function. PROGRESS IN BRAIN RESEARCH 2011; 194:1-25. [PMID: 21867791 PMCID: PMC4305334 DOI: 10.1016/b978-0-444-53815-4.00020-0] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A reliable neural interface that lasts a lifetime will lead to the development of neural prosthetic devices as well as the possibility that brain function can be enhanced. Our data demonstrate that a reliable neural interface is best achieved when the surrounding neuropil grows into the electrode tip where it is held securely, allowing myelinated axons to be recorded using implanted amplifiers. Stable single and multiunits were recorded from three implanted subjects and classified according to amplitudes and firing rates. In one paralyzed and mute subject implanted for over 5 years with a double electrode in the speech motor cortex, the single units allowed recognition of over half the 39 English language phonemes detected using a variety of decoding methods. These single units were used by the subject in a speech task where vowel phonemes were recognized and fed back to the subject using audio output. Weeks of training resulted in an 80% success rate in producing four vowels in an adaptation of the classic center-out task used in motor control studies. The importance of using single units was shown in a different task using pure tones that the same subject heard and then sung or hummed in his head. Feedback was associated with smoothly coordinated unit firings. The plasticity of the unit firings was demonstrated over several sessions first without, and then with, feedback. These data suggest that units can be reliably recorded over years, that there is an inverse relationship between single unit firing rate and amplitude, that pattern recognition decoding paradigms can allow phoneme recognition, that single units appear more important than multiunits when precision is important, and that units are plastic in their functional relationships. These characteristics of a reliable neural interface are essential for the development of neural prostheses and also for the future enhancement of human brain function.
Collapse
|
39
|
Cao Y, He W. Synthesis and Characterization of Glucocorticoid Functionalized Poly(N-vinyl pyrrolidone): A Versatile Prodrug for Neural Interface. Biomacromolecules 2010; 11:1298-307. [DOI: 10.1021/bm100095t] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Yu Cao
- Departments of Materials Science and Engineering and Mechanical, Aerospace, and Biomedical Engineering, The University of Tennessee, Knoxville, Tennessee 37996
| | - Wei He
- Departments of Materials Science and Engineering and Mechanical, Aerospace, and Biomedical Engineering, The University of Tennessee, Knoxville, Tennessee 37996
| |
Collapse
|
40
|
Brumberg JS, Nieto-Castanon A, Kennedy PR, Guenther FH. Brain-Computer Interfaces for Speech Communication. SPEECH COMMUNICATION 2010; 52:367-379. [PMID: 20204164 PMCID: PMC2829990 DOI: 10.1016/j.specom.2010.01.001] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This paper briefly reviews current silent speech methodologies for normal and disabled individuals. Current techniques utilizing electromyographic (EMG) recordings of vocal tract movements are useful for physically healthy individuals but fail for tetraplegic individuals who do not have accurate voluntary control over the speech articulators. Alternative methods utilizing EMG from other body parts (e.g., hand, arm, or facial muscles) or electroencephalography (EEG) can provide capable silent communication to severely paralyzed users, though current interfaces are extremely slow relative to normal conversation rates and require constant attention to a computer screen that provides visual feedback and/or cueing. We present a novel approach to the problem of silent speech via an intracortical microelectrode brain computer interface (BCI) to predict intended speech information directly from the activity of neurons involved in speech production. The predicted speech is synthesized and acoustically fed back to the user with a delay under 50 ms. We demonstrate that the Neurotrophic Electrode used in the BCI is capable of providing useful neural recordings for over 4 years, a necessary property for BCIs that need to remain viable over the lifespan of the user. Other design considerations include neural decoding techniques based on previous research involving BCIs for computer cursor or robotic arm control via prediction of intended movement kinematics from motor cortical signals in monkeys and humans. Initial results from a study of continuous speech production with instantaneous acoustic feedback show the BCI user was able to improve his control over an artificial speech synthesizer both within and across recording sessions. The success of this initial trial validates the potential of the intracortical microelectrode-based approach for providing a speech prosthesis that can allow much more rapid communication rates.
Collapse
Affiliation(s)
- Jonathan S. Brumberg
- Department of Cognitive and Neural Systems, Boston University, 677 Beacon Street, Boston, MA, 02215, Telephone: (617) 353- 9481, Fax Number: (617) 353-7755
- Neural Signals, Inc., Duluth, GA 30096, USA
| | | | | | - Frank H. Guenther
- Department of Cognitive and Neural Systems, Boston University, 677 Beacon Street, Boston, MA, 02215, Telephone: (617) 353- 9481, Fax Number: (617) 353-7755
- Division of Health Sciences and Technology, Harvard University - Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA
| |
Collapse
|
41
|
The Electrochemistry of Charge Injection at the Electrode/Tissue Interface. IMPLANTABLE NEURAL PROSTHESES 2 2010. [DOI: 10.1007/978-0-387-98120-8_4] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
42
|
Moxon K, Morizio J, Chapin J, Nicolelis M, Wolf P. Designing a Brain-Machine Interface for Neuroprosthetic Control. ACTA ACUST UNITED AC 2009. [DOI: 10.1201/9781420039054.pt2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
|
43
|
Guenther FH, Brumberg JS, Wright EJ, Nieto-Castanon A, Tourville JA, Panko M, Law R, Siebert SA, Bartels JL, Andreasen DS, Ehirim P, Mao H, Kennedy PR. A wireless brain-machine interface for real-time speech synthesis. PLoS One 2009; 4:e8218. [PMID: 20011034 PMCID: PMC2784218 DOI: 10.1371/journal.pone.0008218] [Citation(s) in RCA: 142] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2009] [Accepted: 11/15/2009] [Indexed: 11/19/2022] Open
Abstract
Background Brain-machine interfaces (BMIs) involving electrodes implanted into the human cerebral cortex have recently been developed in an attempt to restore function to profoundly paralyzed individuals. Current BMIs for restoring communication can provide important capabilities via a typing process, but unfortunately they are only capable of slow communication rates. In the current study we use a novel approach to speech restoration in which we decode continuous auditory parameters for a real-time speech synthesizer from neuronal activity in motor cortex during attempted speech. Methodology/Principal Findings Neural signals recorded by a Neurotrophic Electrode implanted in a speech-related region of the left precentral gyrus of a human volunteer suffering from locked-in syndrome, characterized by near-total paralysis with spared cognition, were transmitted wirelessly across the scalp and used to drive a speech synthesizer. A Kalman filter-based decoder translated the neural signals generated during attempted speech into continuous parameters for controlling a synthesizer that provided immediate (within 50 ms) auditory feedback of the decoded sound. Accuracy of the volunteer's vowel productions with the synthesizer improved quickly with practice, with a 25% improvement in average hit rate (from 45% to 70%) and 46% decrease in average endpoint error from the first to the last block of a three-vowel task. Conclusions/Significance Our results support the feasibility of neural prostheses that may have the potential to provide near-conversational synthetic speech output for individuals with severely impaired speech motor control. They also provide an initial glimpse into the functional properties of neurons in speech motor cortical areas.
Collapse
Affiliation(s)
- Frank H Guenther
- Department of Cognitive and Neural Systems and Sargent College of Health and Rehabilitation Sciences, Boston University, Boston, Massachusetts, United States of America.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Winter JO, Han N, Jensen R, Cogan SF, Rizzo JF. Adhesion molecules promote chronic neural interfaces following neurotrophin withdrawal. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2009:7151-4. [PMID: 19965267 DOI: 10.1109/iembs.2009.5335356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Neural prostheses and recording devices have been successfully interfaced with the nervous system; however, substantial integration issues exist at the biomaterial-tissue interface. In particular, the loss of neurons at the implantation site and the formation of a gliotic scar capsule diminish device performance. We have investigated the potential of a tissue-engineered coating, consisting of adhesion molecule-modified surfaces (i.e., polylysine and collagen) in combination with neurotrophin application (i.e., brain derived neurotrophic factor, BDNF), to enhance the electrode-host interface. Neurite length and density were examined in a retinal explant model. In the presence of BDNF for 7 days, we found no synergistic effect of BDNF and adhesion molecule-modified surfaces on neurite length, although there was a possible increase in neurite density for collagen-coated surfaces. After BDNF withdrawal (7 days BDNF+/7 days BDNF- medium), we found that both polylysine and collagen treated surfaces displayed increases in neurite length and density over negative, untreated control surfaces. These results suggest that adhesion molecules may be used to support chronic neuron-electrode interfaces induced by neurotrophin exposure.
Collapse
Affiliation(s)
- Jessica O Winter
- William G. Lowrie Department of Chemical Engineering, the Ohio State University, Columbus, OH 43210, USA.
| | | | | | | | | |
Collapse
|
45
|
Long-Term Recordings of Multiple, Single-Neurons for Clinical Applications: The Emerging Role of the Bioactive Microelectrode. MATERIALS 2009. [PMCID: PMC5525202 DOI: 10.3390/ma2041762] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
In 1999 we reported an important demonstration of a working brain-machine interface (BMI), in which recordings from multiple, single neurons in sensorimotor cortical areas of rats were used to directly control a robotic arm to retrieve a water reward. Subsequent studies in monkeys, using a similar approach, demonstrated that primates can use a BMI device to control a cursor on a computer screen and a robotic arm. Recent studies in humans with spinal cord injuries have shown that recordings from multiple, single neurons can be used by the patient to control the cursor on a computer screen. The promise is that one day it will be possible to use these control signals from neurons to re-activate the patient’s own limbs. However, the ability to record from large populations of single neurons for long periods of time has been hampered because either the electrode itself fails or the immunological response in the tissue surrounding the microelectrode produces a glial scar, preventing single-neuron recording. While we have largely solved the problem of mechanical or electrical failure of the electrode itself, much less is known about the long term immunological response to implantation of a microelectrode, its effect on neuronal recordings and, of greatest importance, how it can be reduced to allow long term single neuron recording. This article reviews materials approaches to resolving the glial scar to improve the longevity of recordings. The work to date suggests that approaches utilizing bioactive interventions that attempt to alter the glial response and attract neurons to the recording site are likely to be the most successful. Importantly, measures of the glial scar alone are not sufficient to assess the effect of interventions. It is imperative that recordings of single neurons accompany any study of glial activation because, at this time, we do not know the precise relationship between glial activation and loss of neuronal recordings. Moreover, new approaches to immobilize bioactive molecules on microelectrode surfaces while maintaining their functionality may open new avenues for very long term single neuron recording. Finally, it is important to have quantitative measures of glial upregulation and neuronal activity in order to assess the relationship between the two. These types of studies will help rationalize the study of interventions to improve the longevity of recordings from microelectrodes.
Collapse
|
46
|
Purcell EK, Seymour JP, Yandamuri S, Kipke DR. In vivo evaluation of a neural stem cell-seeded prosthesis. J Neural Eng 2009; 6:026005. [PMID: 19287078 DOI: 10.1088/1741-2560/6/2/026005] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Neural prosthetics capable of recording or stimulating neuronal activity may restore function for patients with motor and sensory deficits resulting from injury or degenerative disease. However, overcoming inconsistent recording quality and stability in chronic applications remains a significant challenge. A likely reason for this is the reactive tissue response to the devices following implantation into the brain, which is characterized by neuronal loss and glial encapsulation. We have developed a neural stem cell-seeded probe to facilitate integration of a synthetic prosthesis with the surrounding brain tissue. We fabricated parylene devices that include an open well seeded with neural stem cells encapsulated in an alginate hydrogel scaffold. Quantitative and qualitative data describing the distribution of neuronal, glial, and progenitor cells surrounding seeded and control devices are reported over four time points spanning 3 months. Neuronal loss and glial encapsulation associated with cell-seeded probes were mitigated during the initial week of implantation and exacerbated by 6 weeks post-insertion compared to control conditions. We hypothesize that graft cells secrete neuroprotective and neurotrophic factors that effect the desired healing response early in the study, with subsequent cell death and scaffold degradation accounting for a reversal of these results later. Applications of this biohybrid technology include future long-term neural recording and sensing studies.
Collapse
Affiliation(s)
- E K Purcell
- Department of Biomedical Engineering, University of Michigan, Lurie Biomedical Engineering Building, 1101 Beal Ave., Ann Arbor, MI 48109-2099, USA.
| | | | | | | |
Collapse
|
47
|
|
48
|
|
49
|
HajjHassan M, Chodavarapu V, Musallam S. NeuroMEMS: Neural Probe Microtechnologies. SENSORS 2008; 8:6704-6726. [PMID: 27873894 PMCID: PMC3707475 DOI: 10.3390/s8106704] [Citation(s) in RCA: 130] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2008] [Revised: 09/27/2008] [Accepted: 10/21/2008] [Indexed: 11/25/2022]
Abstract
Neural probe technologies have already had a significant positive effect on our understanding of the brain by revealing the functioning of networks of biological neurons. Probes are implanted in different areas of the brain to record and/or stimulate specific sites in the brain. Neural probes are currently used in many clinical settings for diagnosis of brain diseases such as seizers, epilepsy, migraine, Alzheimer's, and dementia. We find these devices assisting paralyzed patients by allowing them to operate computers or robots using their neural activity. In recent years, probe technologies were assisted by rapid advancements in microfabrication and microelectronic technologies and thus are enabling highly functional and robust neural probes which are opening new and exciting avenues in neural sciences and brain machine interfaces. With a wide variety of probes that have been designed, fabricated, and tested to date, this review aims to provide an overview of the advances and recent progress in the microfabrication techniques of neural probes. In addition, we aim to highlight the challenges faced in developing and implementing ultra-long multi-site recording probes that are needed to monitor neural activity from deeper regions in the brain. Finally, we review techniques that can improve the biocompatibility of the neural probes to minimize the immune response and encourage neural growth around the electrodes for long term implantation studies.
Collapse
Affiliation(s)
- Mohamad HajjHassan
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
| | - Vamsy Chodavarapu
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
| | - Sam Musallam
- Department of Electrical and Computer Engineering, McGill University, 3480 University Street, Montreal, Canada H3A 2A7.
- Department of Physiology, McGill University, 3655 Promenade Osler, Montreal, Canada H3G 1Y6.
| |
Collapse
|
50
|
Abstract
Electrical stimulation of nerve tissue and recording of neural electrical activity are the basis of emerging prostheses and treatments for spinal cord injury, stroke, sensory deficits, and neurological disorders. An understanding of the electrochemical mechanisms underlying the behavior of neural stimulation and recording electrodes is important for the development of chronically implanted devices, particularly those employing large numbers of microelectrodes. For stimulation, materials that support charge injection by capacitive and faradaic mechanisms are available. These include titanium nitride, platinum, and iridium oxide, each with certain advantages and limitations. The use of charge-balanced waveforms and maximum electrochemical potential excursions as criteria for reversible charge injection with these electrode materials are described and critiqued. Techniques for characterizing electrochemical properties relevant to stimulation and recording are described with examples of differences in the in vitro and in vivo response of electrodes.
Collapse
|