1
|
Zhao Z, Wang P, Lu Y. Copper-cobalt dual-site on N-doped carbon nanotube with dual-promoted synergy for glucose electrochemical detection. Anal Chim Acta 2024; 1298:342405. [PMID: 38462349 DOI: 10.1016/j.aca.2024.342405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/01/2024] [Accepted: 02/22/2024] [Indexed: 03/12/2024]
Abstract
Doping specific active sites and accelerating the decisive step of glucose catalysis to construct highly active glucose sensing electrochemical catalysts remains a major challenge for glucose sensing. Herein, we report the detailed design of Cu-Co dual active site N-doped carbon nanotube (CuCo-NCNTs) obtained by electrodeposition modification, programmed warming and calcination for electrochemical glucose detection. In the CuCo-NCNTs material system, Cu serves as the main active site for glucose sensing. Co with good adsorption of hydroxyl groups acts as the site providing hydroxyl groups to provide oxygen source for Cu oxidized glucose sensing. The synergistic effect between the two active sites in the Cu-Co system and the abundant micro-reactive sites exposed by carbon nanotubes greatly ensure the excellent electrocatalytic performance of glucose oxidation reaction. Therefore, CuCo-NCNTs have good electrocatalytic performance with a sensitivity of 0.84 mA mM-1 cm-2 and a detection limit of 1 μM, and also have excellent stability and specificity. DFT calculations elucidate the decisive steps of H-atom removal in the oxidation of glucose by Cu active site N-doped carbon nanotube (Cu-NCNTs) and Co active site N-doped carbon nanotube (CuCo-NCNTs) materials, illustrating the role of oxygen source provided by hydroxyl group adsorption in the electrochemical sensing process of glucose, thus demonstrating that the electrochemical sensing signal of glucose can be effectively enhanced when cobalt species that readily adsorb hydroxyl groups are introduced into the materials.
Collapse
Affiliation(s)
- Zhenlu Zhao
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China; State Key Lab of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, Jilin, China.
| | - Peihan Wang
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China
| | - Yizhong Lu
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China
| |
Collapse
|
2
|
Boucheta H, Zouaoui E, Ferkous H, Madaci A, Yadav KK, Benguerba Y. Advancing Diabetes Management: The Future of Enzyme-Less Nanoparticle-Based Glucose Sensors-A Review. J Diabetes Sci Technol 2024:19322968241236211. [PMID: 38506487 DOI: 10.1177/19322968241236211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
BACKGROUND Glucose is vital for biological processes, requiring blood sugar levels to be maintained between 3.88 and 6.1 mmol/L, especially during fasting. Elevated levels signal diabetes, a global concern affecting 537 million people, necessitating effective glucose-monitoring devices. METHOD Enzyme-based sensors, though selective, are sensitive to environmental factors. Nonenzymatic sensors, especially those with nanoparticles, offer stability, high surface area, and cost-effectiveness. Existing literature supports their immediate glucose oxidation, showcasing exceptional sensitivity. RESULTS This review details nonenzymatic sensors, highlighting materials, detection limits, and the promise of nanoparticle-based designs, which exhibit enhanced sensitivity and selectivity in glucose detection. CONCLUSION Nanoparticle-based sensors, as reviewed, show potential for glucose monitoring, overcoming enzyme-based limitations. The conclusion suggests future directions for advancing these sensors, emphasizing ongoing innovation in this critical research area.
Collapse
Affiliation(s)
- Hana Boucheta
- Laboratory of Physico-Chemistry Research on Surfaces and Interfaces, University of 20 August 1955, Skikda, Algeria
- Department of Process Engineering, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
- Laboratory of Catalysis, Bio-Process and Environment, Department of Process Engineering, University of 20 August 1955, Skikda, Algeria
| | - Emna Zouaoui
- Department of Process Engineering, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
- Laboratory of Catalysis, Bio-Process and Environment, Department of Process Engineering, University of 20 August 1955, Skikda, Algeria
| | - Hana Ferkous
- Laboratory of Mechanical Engineering and Materials, Faculty of Technology, University of 20 August 1955, Skikda, Algeria
| | - Anis Madaci
- Institute of Analytical Sciences, University of Lyon, Villeurbanne, France
- Laboratory of Materials and Electronics Systems, University El-Bachir El-Ibrahimi Bordj Bou Arreridj, Bordj Bou Arreridj, Algeria
| | - Krishna Kumar Yadav
- Faculty of Science and Technology, Madhyanchal Professional University, Bhopal, India
- Environmental and Atmospheric Sciences Research Group, Scientific Research Center, Al-Ayen University, Nasiriyah, Iraq
| | - Yacine Benguerba
- Laboratoire de Biopharmacie et Pharmacotechnie, Université Ferhat Abbas Sétif-1, Sétif, Algeria
| |
Collapse
|
3
|
Jeyachandran S, Chellapandian H, Ali N. Advancements in Composite Materials and Their Expanding Role in Biomedical Applications. Biomimetics (Basel) 2023; 8:518. [PMID: 37999159 PMCID: PMC10669831 DOI: 10.3390/biomimetics8070518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/18/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023] Open
Abstract
The synthesis of a Ni-doped ZnO nanocomposite incorporating chitosan (CS/Ni-doped ZnO) was achieved via a precipitation method, followed by annealing at 250 °C. This study comprehensively examined the nanocomposite's structural, functional, morphological, and porosity properties using various analytical techniques, including X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), high-resolution scanning electron microscopy (HR-SEM), transmission electron microscopy (TEM), and Brunauer-Emmett-Teller (BET) analysis. The presence of chitosan (CS) and nickel (Ni) within the nanocomposite, along with their influence on reducing the band gap of ZnO particles and enhancing the generation of electron-hole pairs, was confirmed using UV-visible near-infrared spectroscopy (UV-vis-NIR). The electrochemical properties of the CS/Ni-doped ZnO nanocomposite were investigated via electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) by utilizing a phosphate buffer solution with a pH of 6, which closely resembled the typical pH of bacterial cell walls. Finally, the prepared CS/Ni-doped ZnO nanocomposite was evaluated for its antibacterial and anticancer activities. The results demonstrated the highest inhibition of bacterial growth in P. vulgaris, whereas the lowest inhibition was found in S. aureus across various concentrations, thus highlighting its potential in antimicrobial applications. The cytotoxicity of CS/Ni-doped ZnO nanocomposites demonstrated remarkable effects with a half-maximum inhibitory concentration of approximately 80 ± 0.23 µg mL-1 against MCF-7 breast cancer cell lines, following a dose-dependent manner.
Collapse
Affiliation(s)
- Sivakamavalli Jeyachandran
- Lab in Biotechnology & Biosignal Transduction, Department of Orthodontics, Saveetha Dental College & Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai 600077, India
| | - Hethesh Chellapandian
- Lab in Biotechnology & Biosignal Transduction, Department of Orthodontics, Saveetha Dental College & Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai 600077, India
| | - Nemat Ali
- Department of Pharmacology and Toxicology, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
| |
Collapse
|
4
|
Rasheed M, Saira F, Batool Z, Khan HM, Yaseen J, Arshad M, Kalsoom A, Ahmed HE, Ashiq MN. Facile synthesis of a CuSe/PVP nanocomposite for ultrasensitive non-enzymatic glucose biosensing. RSC Adv 2023; 13:26755-26765. [PMID: 37681046 PMCID: PMC10481426 DOI: 10.1039/d3ra03175f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 08/03/2023] [Indexed: 09/09/2023] Open
Abstract
Non-enzymatic glucose biosensors show high sensitivity, lower response time, wide linear range and low cost. Copper based composites show excellent electrocatalytic tunability and lead to a better charge transfer in electrochemical non-enzymatic glucose biosensors. In this work, a nanocomposite of polyvinylpyrrolidone (PVP) and copper selenide was synthesized by a facile one pot sol gel method. Synthesized nanomaterials were characterized by XRD, FTIR, UV-visible spectroscopy, SEM, EDS and XPS techniques. Electrochemical behavior was analyzed by cyclic voltammetry (CV), electrochemical impendence (EIS) and chronoamperometry techniques. XRD analysis revealed a hexagonal structure and crystalline nature of CuSe/PVP. FTIR spectra depicted C-N bonding at 1284 cm-1 and C[double bond, length as m-dash]O stretching at 1634 cm-1, which indicated the presence of PVP in the nanocomposite. Stretching at 823 cm-1 was attributed to the presence of copper selenide. UV-visible absorption indicated the bandgap of copper selenide/PVP at 2.7 eV. SEM analysis revealed a flake like morphology of CuSe/PVP. EDS and XPS analysis confirmed the presence of copper and selenium in the prepared nanocomposite. Prior to employing for biosensing applications, it is important to evaluate the antibacterial activity of nanomaterials for long term use in biological in vitro testing. These materials have shown an efficient inhibition zone of 26 mm against Gram negative Pseudomonas at 50 μg ml-1 and MIC value of 10 μg ml-1. Cyclic voltammetry shows that CuSe/PVP is a promising biosensor for monitoring glucose levels in a wide linear range of 0.5 mM to 3 mM at an excellent sensitivity of 13 450 μA mM-1 cm-2 with an LOD of 0.223 μM. Chronoamperometry measurements revealed a selective behavior of CuSe/PVP for glucose biosensing amongst ascorbic acid and dopamine as common interfering molecules. The nanocomposite was stable after 8 repeated cycles with 92% retention for glucose sensing capacity. This is attributed to the stable nature of the CuSe/PVP nanocomposite as well as higher surface area of available active sites. Herein the CuSe/PVP nanocomposite offered reasonable selectivity, high sensitivity wide linear range with very low LOD, as well as being abundant in nature, this Cu based biosensor has promising applications for future point of care tests (POCT).
Collapse
Affiliation(s)
- Momna Rasheed
- Institute of Physics, The Islamia University of Bahawalpur Pakistan
| | - Farhat Saira
- Nanoscience and Technology Division, National Center for Physics (NCP) Islamabad Pakistan
| | - Zahida Batool
- Institute of Physics, The Islamia University of Bahawalpur Pakistan
| | - Hasan M Khan
- Institute of Physics, The Islamia University of Bahawalpur Pakistan
| | - Junaid Yaseen
- Institute of Physics, The Islamia University of Bahawalpur Pakistan
| | - Muhammad Arshad
- Nanoscience and Technology Division, National Center for Physics (NCP) Islamabad Pakistan
| | | | - Hafiz Ejaz Ahmed
- Institute of Physics, The Islamia University of Bahawalpur Pakistan
| | - Muhammad Naeem Ashiq
- Institute of Chemical Sciences, Bahauddin Zakariya University of Multan Pakistan
| |
Collapse
|
5
|
Patra S, Sahu KM, Reddy AA, Swain SK. Polymer and biopolymer based nanocomposites for glucose sensing. INT J POLYM MATER PO 2023. [DOI: 10.1080/00914037.2023.2175824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Affiliation(s)
- Swapnita Patra
- Department of Chemistry, Veer Surendra Sai University of Technology, Burla, Sambalpur, Odisha, India
| | - Krishna Manjari Sahu
- Department of Chemistry, Veer Surendra Sai University of Technology, Burla, Sambalpur, Odisha, India
| | - A. Amulya Reddy
- Department of Chemistry, Veer Surendra Sai University of Technology, Burla, Sambalpur, Odisha, India
| | - Sarat K. Swain
- Department of Chemistry, Veer Surendra Sai University of Technology, Burla, Sambalpur, Odisha, India
| |
Collapse
|
6
|
High-performance enzyme-free glucose and hydrogen peroxide sensors based on bimetallic AuCu nanoparticles coupled with multi-walled carbon nanotubes. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
7
|
Ashrafi M, Salimi A. Dandelion-like CoOx nanostructures decorated with CdS nanoparticles toward the photoelectrocatalytic enzymeless glucose oxidation and detection. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2023. [DOI: 10.1007/s13738-022-02728-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
8
|
Chahrour KM, Ooi PC, Nazeer AA, Al-Hajji LA, Jubu PR, Dee CF, Ahmadipour M, Hamzah AA. CuO/Cu/rGO nanocomposite anodic titania nanotubes for boosted non-enzymatic glucose biosensors. NEW J CHEM 2023. [DOI: 10.1039/d3nj00666b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
Highly arranged porous anodic titania (TiO2) nanotube arrays (ATNT) were fruitfully fabricated by the anodization of Ti foil in an ammonium fluoride electrolyte.
Collapse
Affiliation(s)
- Khaled M. Chahrour
- Mechanical Engineering Dept., Faculty of Engineering, Karabuk University, 78050, Karabuk, Turkey
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Poh Choon Ooi
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Ahmed Abdel Nazeer
- Nanotechnology and Advanced Materials Program, Energy & Building Research Center, Kuwait Institute for Scientific Research (KISR), P.O. Box 24885, Safat, 13109, Kuwait
- Electrochemistry Laboratory, Physical Chemistry Department, National Research Center, Giza, Egypt
| | - Latifa A. Al-Hajji
- Nanotechnology and Advanced Materials Program, Energy & Building Research Center, Kuwait Institute for Scientific Research (KISR), P.O. Box 24885, Safat, 13109, Kuwait
| | - Peverga R. Jubu
- Department of Physics, University of Agriculture Makurdi (Now Joseph Sarwuan Tarka University Makurdi), P.M.B. 2373, Makurdi, Benue State, Nigeria
| | - Chang Fu Dee
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Mohsen Ahmadipour
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| | - Azrul Azlan Hamzah
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia
| |
Collapse
|
9
|
Hydroxyl adsorption derived reactive oxygen species from carbon paper-supported Cu2O for enhanced electrochemical glucose sensing. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
10
|
Rezaie M, Nemati F, Firoozbakhtian A, Tabesh H, Ganjali MR, Hosseini M. Three‐Dimensional Graphene Network Decorated with Bimetallic Cerium/Copper Oxide Nanoparticles for Non‐Enzymatic Diagnosis of Phenylketonuria. ChemistrySelect 2022. [DOI: 10.1002/slct.202203123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Maryam Rezaie
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Fatemeh Nemati
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Ali Firoozbakhtian
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| | - Hadi Tabesh
- Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran Iran
| | - Mohammad Reza Ganjali
- Center of Excellence in Electrochemistry School of Chemistry College of Science University of Tehran Tehran 1439817435 Iran
| | - Morteza Hosseini
- Nanobiosensors Lab Department of Life Science Engineering Faculty of New Sciences & Technologies University of Tehran Tehran 1439817435 Iran
| |
Collapse
|
11
|
Farahmandpour M, Haghshenas H, Kordrostami Z. Blood glucose sensing by back gated transistor strips sensitized by CuO hollow spheres and rGO. Sci Rep 2022; 12:21872. [PMID: 36536057 PMCID: PMC9763381 DOI: 10.1038/s41598-022-26287-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
In this work, a highly sensitive flexible glucose sensor based on a field effect transistor (FET) has been fabricated. It is shown that the proposed flexible transistor can be used as new non-enzymatic blood glucose test strips. CuO hollow-spheres decorated with reduced graphene oxide have been synthesized using the hydrothermal method. The shells of the hollow micro-spheres are formed by nanostructures. The synthesized nanostructured hollow micro-spheres (rGO/CuO-NHS) are deposited on a flexible PET substrate between interdigitated electrodes as the channel of a back gate transistor. The channel concentration and the FET bias are optimized so that the sensor exhibits extremely low limit of detection and high sensitivity. The combination of selective porous CuO hollow spheres and the high surface to volume ratio of their nanostructured shells with the high mobility and high conductivity rGO led to faster and higher charge-transfer capability and superior electro-catalyst activity for glucose oxidation. The glucose-dependent electrical responses of the sensor is measured in both resistive and transistor action modes. The amplification of the current by the induced electric field of the gate in the proposed FET-based biosensor provides advantages such as higher sensitivity and lower limit of detection compared to the resistive sensor. The flexible glucose sensor has a sensitivity of 600 μA μM-1 and a limit of detection of 1 nM with high reproducibility, good stability, and highly selectivity. The high accuracy response of the biosensor towards the real blood serum samples showed that it can be used as a test strip for glucose detection in real blood samples.
Collapse
Affiliation(s)
- Milad Farahmandpour
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| | - Hassan Haghshenas
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| | - Zoheir Kordrostami
- grid.444860.a0000 0004 0600 0546Department of Electrical and Electronic Engineering, Shiraz University of Technology, Shiraz, Iran ,grid.444860.a0000 0004 0600 0546Research Center for Design and Fabrication of Advanced Electronic Devices, Shiraz University of Technology, Shiraz, Iran
| |
Collapse
|
12
|
Rezaie M, Nemati F, Firoozbakhtian A, Tabesh H, Hosseini M. Three-dimensional Graphene Network Decorated with Bimetallic Cerium/Copper Oxide Nanoparticles for Non-enzymatic Diagnosis of Phenylketonuria. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Ren Z, Dong R, Liu Y. Free-standing hybrid material of Cu/Cu 2O/CuO modified by graphene with commercial Cu foil using for non-enzymatic glucose detection. NANOTECHNOLOGY 2022; 33:505702. [PMID: 36084452 DOI: 10.1088/1361-6528/ac90cd] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 09/09/2022] [Indexed: 06/15/2023]
Abstract
Free-standing Cu/Cu2O/CuO modified by graphene was formed through two steps: Firstly, the commercial Cu foil was thermal annealed to form Cu/Cu2O/CuO; Secondly, the Cu/Cu2O/CuO was modified by graphene through electrochemical exfoliated method. The SEM, XRD, TEM and XPS have been used to characterize the morphology, the crystalline phase, and the surface composition of the hybrid electrode as-prepared. The effects of Cu and its oxides on graphene has been uncovered by the Raman results. The sensitivity of the glucose sensor in 0.1 M NaOH by using the as-prepared hybrid material reaches 3102μA·mM-1cm-2within a linear range of 0.002-2.88 mM, which is better than that of the Cu/graphene and the Cu/Cu2O/CuO prepared at the same conditions. The sensor also shows excellent anti-interference ability, good cycling stability and time stability. The advantage of the sensor is caused by the strengthened synergistic effects between the graphene and the Cu/Cu2O/CuO due to the alleviated detrimental effects of the metal on the property of the graphene through using oxides middle layer as well as the large active area that obtained. This work provides a new way to study the effects of graphene in improving the property of the metal oxide especially in using for glucose sensor.
Collapse
Affiliation(s)
- Zhaodi Ren
- Beijing Key Laboratory of Work Safety Intelligent Monitoring, School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, People's Republic of China
| | - Rui Dong
- Beijing Key Laboratory of Work Safety Intelligent Monitoring, School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, People's Republic of China
| | - Yuanan Liu
- Beijing Key Laboratory of Work Safety Intelligent Monitoring, School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, People's Republic of China
| |
Collapse
|
14
|
Lee SJ, Jang H, Lee DN. Inorganic Nanoflowers—Synthetic Strategies and Physicochemical Properties for Biomedical Applications: A Review. Pharmaceutics 2022; 14:pharmaceutics14091887. [PMID: 36145635 PMCID: PMC9505446 DOI: 10.3390/pharmaceutics14091887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 08/30/2022] [Accepted: 09/02/2022] [Indexed: 11/29/2022] Open
Abstract
Nanoflowers, which are flower-shaped nanomaterials, have attracted significant attention from scientists due to their unique morphologies, facile synthetic methods, and physicochemical properties such as a high surface-to-volume ratio, enhanced charge transfer and carrier immobility, and an increased surface reaction efficiency. Nanoflowers can be synthesized using inorganic or organic materials, or a combination of both (called a hybrid), and are mainly used for biomedical applications. Thus far, researchers have focused on hybrid nanoflowers and only a few studies on inorganic nanoflowers have been reported. For the first time in the literature, we have consolidated all the reports on the biomedical applications of inorganic nanoflowers in this review. Herein, we review some important inorganic nanoflowers, which have applications in antibacterial treatment, wound healing, combinatorial cancer therapy, drug delivery, and biosensors to detect diseased conditions such as diabetes, amyloidosis, and hydrogen peroxide poisoning. In addition, we discuss the recent advances in their biomedical applications and preparation methods. Finally, we provide a perspective on the current trends and potential future directions in nanoflower research. The development of inorganic nanoflowers for biomedical applications has been limited to date. Therefore, a diverse range of nanoflowers comprising inorganic elements and materials with composite structures must be synthesized using ecofriendly synthetic strategies.
Collapse
Affiliation(s)
- Su Jung Lee
- Ingenium College of Liberal Arts (Chemistry), Kwangwoon University, Seoul 01897, Korea
| | - Hongje Jang
- Department of Chemistry, Kwangwoon University, Seoul 01897, Korea
- Correspondence: (H.J.); (D.N.L.)
| | - Do Nam Lee
- Ingenium College of Liberal Arts (Chemistry), Kwangwoon University, Seoul 01897, Korea
- Correspondence: (H.J.); (D.N.L.)
| |
Collapse
|
15
|
A fully handwritten-on-paper copper nanoparticle ink-based electroanalytical sweat glucose biosensor fabricated using dual-step pencil and pen approach. Anal Chim Acta 2022; 1227:340257. [DOI: 10.1016/j.aca.2022.340257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 11/20/2022]
|
16
|
Miyagi K, Takano T, Teramoto Y. Glucose‐sensitive structural color change of cholesteric liquid crystal formed by hydroxypropyl cellulose with phenylboronic acid moieties. J Appl Polym Sci 2022. [DOI: 10.1002/app.52984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Kazuma Miyagi
- Department of Forest Resource Chemistry, Forestry and Forest Products Research Institute Forest Research and Management Organization Ibaraki Japan
| | - Toshiyuki Takano
- Division of Forest and Biomaterials Science, Graduate School of Agriculture Kyoto University Kyoto Japan
| | - Yoshikuni Teramoto
- Division of Forest and Biomaterials Science, Graduate School of Agriculture Kyoto University Kyoto Japan
| |
Collapse
|
17
|
Radhakrishnan S, Lakshmy S, Santhosh S, Kalarikkal N, Chakraborty B, Rout CS. Recent Developments and Future Perspective on Electrochemical Glucose Sensors Based on 2D Materials. BIOSENSORS 2022; 12:467. [PMID: 35884271 PMCID: PMC9313175 DOI: 10.3390/bios12070467] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 05/09/2023]
Abstract
Diabetes is a health disorder that necessitates constant blood glucose monitoring. The industry is always interested in creating novel glucose sensor devices because of the great demand for low-cost, quick, and precise means of monitoring blood glucose levels. Electrochemical glucose sensors, among others, have been developed and are now frequently used in clinical research. Nonetheless, despite the substantial obstacles, these electrochemical glucose sensors face numerous challenges. Because of their excellent stability, vast surface area, and low cost, various types of 2D materials have been employed to produce enzymatic and nonenzymatic glucose sensing applications. This review article looks at both enzymatic and nonenzymatic glucose sensors made from 2D materials. On the other hand, we concentrated on discussing the complexities of many significant papers addressing the construction of sensors and the usage of prepared sensors so that readers might grasp the concepts underlying such devices and related detection strategies. We also discuss several tuning approaches for improving electrochemical glucose sensor performance, as well as current breakthroughs and future plans in wearable and flexible electrochemical glucose sensors based on 2D materials as well as photoelectrochemical sensors.
Collapse
Affiliation(s)
- Sithara Radhakrishnan
- Centre for Nano and Material Science, Jain University, Jain Global Campus, Jakkasandra, Ramanagara, Bangalore 562 112, Karnataka, India;
| | - Seetha Lakshmy
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam 686 560, Kerala, India; (S.L.); (S.S.); (N.K.)
| | - Shilpa Santhosh
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam 686 560, Kerala, India; (S.L.); (S.S.); (N.K.)
| | - Nandakumar Kalarikkal
- International and Inter University Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam 686 560, Kerala, India; (S.L.); (S.S.); (N.K.)
- School of Pure and Applied Physics, Mahatma Gandhi University, Kottayam 686 560, Kerala, India
- School of Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam 686 560, Kerala, India
| | - Brahmananda Chakraborty
- High Pressure and Synchroton Radiation Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, Maharashtra, India
- Homi Bhabha National Institute, Mumbai 400 094, Maharashtra, India
| | - Chandra Sekhar Rout
- Centre for Nano and Material Science, Jain University, Jain Global Campus, Jakkasandra, Ramanagara, Bangalore 562 112, Karnataka, India;
| |
Collapse
|
18
|
Lv HW, Li QF, Peng HL. Protein templated Au-CuO bimetallic nanoclusters toward neutral glucose sensing. CHINESE J CHEM PHYS 2022. [DOI: 10.1063/1674-0068/cjcp2005076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
In this study, the application of bovine serum albumin (BSA) as a carrier to glucose-sensitive materials for the detection of glucose was proposed. Au-CuO bimetallic nanoclusters (Au-CuO/BSA) were prepared using BSA as a template, the new sensing material (Au-CuO/BSA/MWCNTs) was synthesized by mixing with multi-walled carbon nanotubes (MWCNT) and applied to non-enzymatic electrochemical sensors to detect glucose stably and effectively under neutral condition. The scanning electron microscopy was used to investigate the morphology of the synthesized nanocomposite. The electrochemical properties of the sensor were studied by cyclic voltammetry. Glucose detection experiments show that Au-CuO/BSA/MWCNTs/Au electrode has good glucose detection ability, stability, accuracy, repeatability, and high selectivity in neutral environment. Unlike existing glucose-sensitive materials, due to the use of BSA, the composite material is firmly fixed to the electrode surface without a Nafion solution, which reduces the current blocking effect on the modified electrode. The composite materials can be effectively preserved for extremely long periods, higher than 80% activity is maintained at room temperature in a closed environment for 3 to 4 months, due to the special effects of BSA. In addition, the feasibility of using BSA in glucose-sensitive materials is confirmed.
Collapse
Affiliation(s)
- Hong-wei Lv
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| | - Quan-fu Li
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| | - Hui-ling Peng
- College of Electronic Engineering, Guangxi Normal University, Guilin 541004, China
| |
Collapse
|
19
|
Lai WF, Obireddy SR, Zhang H, Zhang D, Wong WT. Advances in analysis of pharmaceuticals by using graphene-based sensors. ChemMedChem 2022; 17:e202200111. [PMID: 35618680 DOI: 10.1002/cmdc.202200111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 05/23/2022] [Indexed: 11/10/2022]
Abstract
Safe and effective use of drugs relies on proper pharmaceutical analysis. Graphene has been extensively used to construct sensors for this purpose. Over the years, a large variety of pharmaceutical sensors have been developed from graphene or its derivatives. This articles reviews the current status of sensor development from graphene and its derivatives, and discusses the use of graphene-based sensors in pharmaceutical analysis. It is hoped that this article cannot only offer a snapshot of recent advances in the fabrication and use of graphene-based sensors, but can also provide insights into future engineering and optimization of the sensors for effective pharmaceutical analysis.
Collapse
Affiliation(s)
- Wing-Fu Lai
- The Chinese University of Hong Kong, School of Life and Health Sciences, 518172, Shenzhen, CHINA
| | - Sreekanth Reddy Obireddy
- Sri Krishnadevaraya University, Chemistry, TIRUPATI NATIONAL HIGHWAY, ITUKALAPALLI, 515004, India, 515003, ANANTHAPURAMU, INDIA
| | - Haotian Zhang
- The Chinese University of Hong Kong, School of Life and Health Sciences, CHINA
| | | | - Wing-Tak Wong
- The Hong Kong Polytechnic University, Applied Biology and Chemical Technology, CHINA
| |
Collapse
|
20
|
Arif D, Hussain Z, Abbasi AD, Sohail M. Ag Functionalized In2O3 Derived From MIL-68(In) as an Efficient Electrochemical Glucose Sensor. Front Chem 2022; 10:906031. [PMID: 35615318 PMCID: PMC9124854 DOI: 10.3389/fchem.2022.906031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 04/19/2022] [Indexed: 11/13/2022] Open
Abstract
In this study, Ag@In2O3 modified nickel foam (NF) was reported for its role as a non-enzymatic glucose sensor. Ag@In2O3 was prepared by a simple two-step method; preparation of a metal-organic framework (MOF) MIL-68(In) by solvothermal method, entrapment of Ag + by adding AgNO3 then drying it for 2 h to complete the entrapment process and subsequent calcination at 650°C for 3 h. The Ag@In2O3 modified NF was employed as a non-enzymatic glucose sensor to determine glucose concentrations in an alkaline medium. Two linear ranges were obtained from Ag@In2O3 modified electrode, i.e., 10 μM to 0.8 mM and 0.8–2.16 mM with a sensitivity of 3.31 mA mM−1 cm−2 and 1.51 mA mM−1 cm−2 respectively, with a detection limit of 0.49 µM. Ag@In2O3 modified NF exhibited high selectivity for glucose, among other interfering agents.
Collapse
Affiliation(s)
- Dooa Arif
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| | - Zakir Hussain
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
- *Correspondence: Zakir Hussain,
| | - Amna Didar Abbasi
- Department of Materials Engineering, School of Chemical and Materials Engineering (SCME), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| | - Manzar Sohail
- Department of Chemistry, School of Natural Sciences (SNS), National University of Sciences & Technology (NUST), Islamabad, Pakistan
| |
Collapse
|
21
|
Muslu E, Eren E, Oksuz AU. Prussian Blue-Based Flexible Thin Film Nanoarchitectonics for Non-enzymatic Electrochemical Glucose Sensor. J Inorg Organomet Polym Mater 2022. [DOI: 10.1007/s10904-022-02290-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
22
|
Wang R, Liu X, Zhao Y, Qin J, Xu H, Dong L, Gao S, Zhong L. Novel electrochemical non-enzymatic glucose sensor based on 3D Au@Pt core–shell nanoparticles decorated graphene oxide/multi-walled carbon nanotubes composite. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107061] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
23
|
Arikan K, Burhan H, Sahin E, Sen F. A sensitive, fast, selective, and reusable enzyme-free glucose sensor based on monodisperse AuNi alloy nanoparticles on activated carbon support. CHEMOSPHERE 2022; 291:132718. [PMID: 34756949 DOI: 10.1016/j.chemosphere.2021.132718] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 10/21/2021] [Accepted: 10/25/2021] [Indexed: 06/13/2023]
Abstract
In this study, a glucose sensor modified with activated carbon supported gold-nickel (AuNi@AC) metal nanoparticles was prepared for the early diagnosis of diabetes. Electrochemical tests were carried out by determining the optimum working conditions of the prepared glucose sensor. The characterization analyses of the designed glucose sensor were performed by Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), X-Ray Photoelectron Spectroscopy (XPS) and Raman Spectroscopy. It was determined that the average particle size of the nanoparticles in the AuNi alloy structure was 2.03 ± 0.37 nm. The determined detection limit of the AuNi@AC nanosensor was calculated as 0.41 μM as a result of the high linear range provided up to 1.7 mM. In addition, the sensitivity of AuNi@AC nanosensor to glucose, which has a high sensitivity value of 1955 μA mM-1 cm-2, was determined.
Collapse
Affiliation(s)
- Kubilay Arikan
- Sen Research Group, Biochemistry Department, Faculty of Arts and Science, Dumlupınar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey
| | - Hakan Burhan
- Sen Research Group, Biochemistry Department, Faculty of Arts and Science, Dumlupınar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey
| | - Elif Sahin
- Department of Chemistry, Faculty of Sciences, Dokuz Eylul University, Buca, İzmir, Turkey.
| | - Fatih Sen
- Sen Research Group, Biochemistry Department, Faculty of Arts and Science, Dumlupınar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
| |
Collapse
|
24
|
Sim D, Brothers MC, Slocik JM, Islam AE, Maruyama B, Grigsby CC, Naik RR, Kim SS. Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2104426. [PMID: 35023321 PMCID: PMC8895156 DOI: 10.1002/advs.202104426] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 11/19/2021] [Indexed: 05/04/2023]
Abstract
Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various occupational sectors, such as industry, academy, sports, recreation, and military. While various commercially wearable sensors are on the market with their capability of "quantitative assessments" on human health, physical, and psychological states, their sensing is mostly based on physical traits, and thus lacks precision in HHPM. Minimally or noninvasive biomarkers detectable from the human body, such as body fluid (e.g., sweat, tear, urine, and interstitial fluid), exhaled breath, and skin surface, can provide abundant additional information to the HHPM. Detecting these biomarkers with novel or existing sensor technologies is emerging as critical human monitoring research. This review provides a broad perspective on the state of the art biosensor technologies for HHPM, including the list of biomarkers and their physiochemical/physical characteristics, fundamental sensing principles, and high-performance sensing transducers. Further, this paper expands to the additional scope on the key technical challenges in applying the current HHPM system to the real field.
Collapse
Affiliation(s)
- Daniel Sim
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
- Research Associateship Program (RAP)the National Academies of Sciences, Engineering and MedicineWashingtonDC20001USA
- Integrative Health & Performance Sciences DivisionUES Inc.DaytonOH45432USA
| | - Michael C. Brothers
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
- Integrative Health & Performance Sciences DivisionUES Inc.DaytonOH45432USA
| | - Joseph M. Slocik
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Ahmad E. Islam
- Air Force Research LaboratorySensors DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Benji Maruyama
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson Air Force BaseOH 45433USA
| | - Claude C. Grigsby
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| | - Rajesh R. Naik
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| | - Steve S. Kim
- Air Force Research Laboratory711th Human Performance WingWright‐Patterson Air Force BaseOH 45433USA
| |
Collapse
|
25
|
Zhang H, He R, Niu Y, Han F, Li J, Zhang X, Xu F. Graphene-enabled wearable sensors for healthcare monitoring. Biosens Bioelectron 2022; 197:113777. [PMID: 34781177 DOI: 10.1016/j.bios.2021.113777] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 11/05/2021] [Accepted: 11/06/2021] [Indexed: 01/19/2023]
Abstract
Wearable sensors in healthcare monitoring have recently found widespread applications in biomedical fields for their non- or minimal-invasive, user-friendly and easy-accessible features. Sensing materials is one of the major challenges to achieve these superiorities of wearable sensors for healthcare monitoring, while graphene-based materials with many favorable properties have shown great efficiency in sensing various biochemical and biophysical signals. In this paper, we review state-of-the-art advances in the development and modification of graphene-based materials (i.e., graphene, graphene oxide and reduced graphene oxide) for fabricating advanced wearable sensors with 1D (fibers), 2D (films) and 3D (foams/aerogels/hydrogels) macroscopic structures. We summarize the structural design guidelines, sensing mechanisms, applications and evolution of the graphene-based materials as wearable sensors for healthcare monitoring of biophysical signals (e.g., mechanical, thermal and electrophysiological signals) and biochemical signals from various body fluids and exhaled gases. Finally, existing challenges and future prospects are presented in this area.
Collapse
Affiliation(s)
- Huiqing Zhang
- Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, China; The Key Laboratory of Biomedical Information Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Rongyan He
- The Key Laboratory of Biomedical Information Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Yan Niu
- The Key Laboratory of Biomedical Information Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Fei Han
- The Key Laboratory of Biomedical Information Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China
| | - Jing Li
- Department of Plastic and Burn Surgery, Tangdu Hospital, Fourth Military Medical University, Xi'an, Shaanxi, 710038, China
| | - Xiongwen Zhang
- Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, China.
| |
Collapse
|
26
|
Introducing Graphene–Indium Oxide Electrochemical Sensor for Detecting Ethanol in Aqueous Samples with CCD-RSM Optimization. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10020042] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
There is significant demand for portable sensors that can deliver selective and sensitive measurement of ethanol on-site. Such sensors have application across many industries, including clinical and forensic work as well as agricultural and environmental analysis. Here, we report a new graphene–indium oxide electrochemical sensor for the determination of ethanol in aqueous samples. Graphene layers were functionalised by anchoring In2O3 to its surface and the developed composite was used as a selective electrochemical sensor for sensing ethanol through cyclic voltammetry. The detection limit of the sensor was 0.068 mol/L and it showed a linear response to increasing ethanol in the environment up to 1.2 mol/L. The most significant parameters involved and their interactions in the response of the sensor and optimization procedures were studied using a four-factor central composite design (CCD) combined with response surface modelling (RSM). The sensor was applied in the detection of ethanol in authentic samples.
Collapse
|
27
|
Dendritic Cu(OH)2 nanostructures decorated pencil graphite electrode as a highly sensitive and selective impedimetric non-enzymatic glucose sensor in real human serum blood samples. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-021-02883-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
28
|
Naikoo GA, Awan T, Salim H, Arshad F, Hassan IU, Pedram MZ, Ahmed W, Faruck HL, Aljabali AAA, Mishra V, Serrano‐Aroca Á, Goyal R, Negi P, Birkett M, Nasef MM, Charbe NB, Bakshi HA, Tambuwala MM. Fourth-generation glucose sensors composed of copper nanostructures for diabetes management: A critical review. Bioeng Transl Med 2022; 7:e10248. [PMID: 35111949 PMCID: PMC8780923 DOI: 10.1002/btm2.10248] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/10/2021] [Accepted: 08/13/2021] [Indexed: 01/31/2023] Open
Abstract
More than five decades have been invested in understanding glucose biosensors. Yet, this immensely versatile field has continued to gain attention from the scientific world to better understand and diagnose diabetes. However, such extensive work done to improve glucose sensing devices has still not yielded desirable results. Drawbacks like the necessity of the invasive finger-pricking step and the lack of optimization of diagnostic interventions still need to be considered to improve the testing process of diabetic patients. To upgrade the glucose-sensing devices and reduce the number of intermediary steps during glucose measurement, fourth-generation glucose sensors (FGGS) have been introduced. These sensors, made using robust electrocatalytic copper nanostructures, improve diagnostic efficiency and cost-effectiveness. This review aims to present the essential scientific progress in copper nanostructure-based FGGS in the past 10 years (2010 to present). After a short introduction, we presented the working principles of these sensors. We then highlighted the importance of copper nanostructures as advanced electrode materials to develop reliable real-time FGGS. Finally, we cover the advantages, shortcomings, and prospects for developing highly sensitive, stable, and specific FGGS.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Tasbiha Awan
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Hiba Salim
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Fareeha Arshad
- Department of BiochemistryAligarh Muslim UniversityAligarhIndia
| | | | - Mona Zamani Pedram
- Faculty of Mechanical Engineering—Energy DivisionK.N. Toosi University of TechnologyTehranIran
| | - Waqar Ahmed
- School of Mathematics and PhysicsCollege of Science, University of LincolnLincolnUK
| | | | - Alaa A. A. Aljabali
- Departmnt of Pharmaceutics and Pharmaceutical TechnologyYarmouk UniversityIrbidJordan
| | - Vijay Mishra
- School of Pharmaceutical SciencesLovely Professional UniversityPhagwaraPunjabIndia
| | - Ángel Serrano‐Aroca
- Biomaterials and Bioengineering LabTranslational Research Centre San Alberto Magno, Catholic University of Valencia San Vicente MártirValenciaSpain
| | - Rohit Goyal
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Poonam Negi
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Martin Birkett
- Department of Mechanical and Construction EngineeringNorthumbria UniversityNewcastle upon TyneUK
| | - Mohamed M. Nasef
- Department of PharmacySchool of Applied Science, University of HuddersfieldUK
| | - Nitin B. Charbe
- Department of Pharmaceutical SciencesRangel College of Pharmacy, Texas A&M UniversityKingsvilleTexasUSA
| | - Hamid A. Bakshi
- School of Pharmacy and Pharmaceutical ScienceUlster UniversityColeraineUK
| | | |
Collapse
|
29
|
Production of copper-graphene nanocomposite as a voltammetric sensor for determination of anti-diabetic metformin using response surface methodology. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106877] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
30
|
Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
31
|
Scandurra A, Censabella M, Boscarino S, Condorelli GG, Grimaldi MG, Ruffino F. Fabrication of Cu(II) oxide-hydroxide nanostructures onto graphene paper by laser and thermal processes for sensitive nano-electrochemical sensing of glucose. NANOTECHNOLOGY 2021; 33:045501. [PMID: 34610585 DOI: 10.1088/1361-6528/ac2d0b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 10/05/2021] [Indexed: 06/13/2023]
Abstract
Glucose electrochemical sensors based on nanostructures of CuO/Cu(OH)2onto graphene paper were prepared by thermal (solid) and nanosecond pulsed laser (molten phase) dewetting of a CuO layer 6 nm thin deposited by sputtering. Dewetted systems, obtained without the use of any binder, act as array of nanoelectrodes. Solid state and molten phase dewetting produce nanostructures of copper oxide-hydroxide with different average size, shape and surface composition. Molten phase dewetting originates particles with size below 100 nm, while solid state dewetting produces particles with average size of about 200 nm. Moreover, molten phase dewetting produce drop-shaped nanostructures, conversely nanostructures derived from solid state dewetting are multifaceted. X-ray photoelectron spectroscopy (XPS) characterization revealed that the surface of nanostructures is formed by a copper(II) species CuO and Cu(OH)2. Shape of anodic branch of the cyclic voltammograms of glucose in alkali solution evidenced a convergent diffusion mechanism. Analytical performances in amperometric mode are as good as or better than other sensors based on copper oxide. Amperometric detection of glucose was done at potential as low as 0.4 V versus saturated calomel electrode by both types of electrodes. Linear range from 50μM to 10 mM, sensitivity ranging from 7 to 43μA cm-2mM-1and detection limit of 7μM was obtained. Good analytical performances were obtained by laser dewetted electrodes with a low copper content up to 1.2 by atoms percentage of the surface. Analytical performance of the proposed electrodes is compliant for the determination of glucose both in blood serum, saliva or tear.
Collapse
Affiliation(s)
- Antonino Scandurra
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Maria Censabella
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Stefano Boscarino
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | | | - Maria Grazia Grimaldi
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| | - Francesco Ruffino
- Department of Physics and Astronomy Ettore Majorana of University of Catania, via Santa Sofia 64, 95123 Catania, Italy
- Institute for Microelectronics and Microsystems of National Research Council of Italy (CNR-IMM), via Santa Sofia 64, 95123 Catania, Italy
| |
Collapse
|
32
|
Preparation, Properties and Applications of the Hybrid Organic/Inorganic Nanocomposite Based on Nanoporous Carbon Matrix. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-021-02050-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
33
|
Goodnight L, Butler D, Xia T, Ebrahimi A. Non-Enzymatic Detection of Glucose in Neutral Solution Using PBS-Treated Electrodeposited Copper-Nickel Electrodes. BIOSENSORS 2021; 11:409. [PMID: 34821625 PMCID: PMC8615574 DOI: 10.3390/bios11110409] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 10/11/2021] [Accepted: 10/13/2021] [Indexed: 05/24/2023]
Abstract
Transition metals have been explored extensively for non-enzymatic electrochemical detection of glucose. However, to enable glucose oxidation, the majority of reports require highly alkaline electrolytes which can be damaging to the sensors and hazardous to handle. In this work, we developed a non-enzymatic sensor for detection of glucose in near-neutral solution based on copper-nickel electrodes which are electrochemically modified in phosphate-buffered saline (PBS). Nickel and copper were deposited using chronopotentiometry, followed by a two-step annealing process in air (Step 1: at room temperature and Step 2: at 150 °C) and electrochemical stabilization in PBS. Morphology and chemical composition of the electrodes were characterized using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Cyclic voltammetry was used to measure oxidation reaction of glucose in sodium sulfate (100 mM, pH 6.4). The PBS-Cu-Ni working electrodes enabled detection of glucose with a limit of detection (LOD) of 4.2 nM, a dynamic response from 5 nM to 20 mM, and sensitivity of 5.47 ± 0.45 μA cm-2/log10(mole.L-1) at an applied potential of 0.2 V. In addition to the ultralow LOD, the sensors are selective toward glucose in the presence of physiologically relevant concentrations of ascorbic acid and uric acid spiked in artificial saliva. The optimized PBS-Cu-Ni electrodes demonstrate better stability after seven days storage in ambient compared to the Cu-Ni electrodes without PBS treatment.
Collapse
Affiliation(s)
- Lindsey Goodnight
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA; (L.G.); (D.B.); (T.X.)
| | - Derrick Butler
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA; (L.G.); (D.B.); (T.X.)
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Tunan Xia
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA; (L.G.); (D.B.); (T.X.)
| | - Aida Ebrahimi
- School of Electrical Engineering and Computer Science, The Pennsylvania State University, University Park, PA 16802, USA; (L.G.); (D.B.); (T.X.)
- Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
34
|
Anichini C, Samorì P. Graphene-Based Hybrid Functional Materials. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100514. [PMID: 34174141 DOI: 10.1002/smll.202100514] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 02/24/2021] [Indexed: 06/13/2023]
Abstract
Graphene is a 2D material combining numerous outstanding physical properties, including high flexibility and strength, extremely high thermal conductivity and electron mobility, transparency, etc., which make it a unique testbed to explore fundamental physical phenomena. Such physical properties can be further tuned by combining graphene with other nanomaterials or (macro)molecules to form hybrid functional materials, which by design can display not only the properties of the individual components but also exhibit new properties and enhanced characteristics arising from the synergic interaction of the components. The implementation of the hybrid approach to graphene also allows boosting the performances in a multitude of technological applications. This review reports the hybrids formed by graphene combined with other low-dimensional nanomaterials of diverse dimensionality (0D, 1D, and 2D) and (macro)molecules, with emphasis on the synthetic methods. The most important applications of these hybrids in the fields of sensing, water purification, energy storage, biomedical, (photo)catalysis, and opto(electronics) are also reviewed, with a special focus on the superior performances of these hybrids compared to the individual, nonhybridized components.
Collapse
Affiliation(s)
- Cosimo Anichini
- Université de Strasbourg, CNRS, ISIS, 8 alleé Gaspard Monge, Strasbourg, 67000, France
| | - Paolo Samorì
- Université de Strasbourg, CNRS, ISIS, 8 alleé Gaspard Monge, Strasbourg, 67000, France
| |
Collapse
|
35
|
Awais A, Arsalan M, Qiao X, Yahui W, Sheng Q, Yue T, He Y. Facial synthesis of highly efficient non-enzymatic glucose sensor based on vertically aligned Au-ZnO NRs. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115424] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
36
|
Abstract
The engineering of an efficient electrochemical sensor based on a bismuth sulfide/reduced graphene oxide (Bi2S3/rGO) composite to detect ascorbic acid (AA) is reported. The Bi2S3 nanorods/rGO composite was synthesized using a facile hydrothermal method. By varying the amount of graphene oxide (GO) added to the synthesis, the morphology and size of Bi2S3 nanorods anchored on the surface of rGO can be tuned. Compared to a bare glassy carbon electrode (GCE), the GCE modified with Bi2S3/rGO composite presented enhanced electrochemical performance, which was attributed to the optimal electron transport between the rGO support and the loaded Bi2S3 as well as to an increase in the number of active catalytic sites. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analysis of Bi2S3/rGO/GCE demonstrate that the active Bi2S3/rGO layer on GCE plays an important role in the electrochemical behavior of the sensor. In particular, the Bi2S3/rGO/GCE sensor shows a wide detecting range (5.0–1200 μM), low detection limit (2.9 µM), good sensitivity (268.8 μA mM−1 cm−2), and sufficient recovery values (97.1–101.6%) for the detection of ascorbic acid.
Collapse
|
37
|
Singh KR, Nayak V, Singh J, Singh AK, Singh RP. Potentialities of bioinspired metal and metal oxide nanoparticles in biomedical sciences. RSC Adv 2021; 11:24722-24746. [PMID: 35481029 PMCID: PMC9036962 DOI: 10.1039/d1ra04273d] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/01/2021] [Indexed: 12/15/2022] Open
Abstract
To date, various reports have shown that metallic gold bhasma at the nanoscale form was used as medicine as early as 2500 B.C. in India, China, and Egypt. Owing to their unique physicochemical, biological, and electronic properties, they have broad utilities in energy, environment, agriculture and more recently, the biomedical field. The biomedical domain has been used in drug delivery, imaging, diagnostics, therapeutics, and biosensing applications. In this review, we will discuss and highlight the increasing control over metal and metal oxide nanoparticle structures as smart nanomaterials utilized in the biomedical domain to advance the role of biosynthesized nanoparticles for improving human health through wide applications in the targeted drug delivery, controlled release drug delivery, wound dressing, tissue scaffolding, and medical implants. In addition, we have discussed concerns related to the role of these types of nanoparticles as an anti-viral agent by majorly highlighting the ways to combat the Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) pandemic, along with their prospects.
Collapse
Affiliation(s)
- Kshitij Rb Singh
- Department of Chemistry, Govt. V.Y.T. PG Autonomous College Durg Chhattisgarh (491001) India
| | - Vanya Nayak
- Department of Biotechnology, Faculty of Science, Indira Gandhi National Tribal University Amarkantak Madhya Pradesh (484886) India +91-91-0934-6565
| | - Jay Singh
- Department of Chemistry, Institute of Science, Banaras Hindu University Varanasi Uttar Pradesh (221005) India
| | - Ajaya Kumar Singh
- Department of Chemistry, Govt. V.Y.T. PG Autonomous College Durg Chhattisgarh (491001) India
| | - Ravindra Pratap Singh
- Department of Biotechnology, Faculty of Science, Indira Gandhi National Tribal University Amarkantak Madhya Pradesh (484886) India +91-91-0934-6565
| |
Collapse
|
38
|
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2020025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
Collapse
|
39
|
Liu F, Su N, Guan R. Enhancement on the Tribological Properties of the Multilayer RGO/Al Matrix Composites by Cu-Coating Method. MATERIALS 2021; 14:ma14123163. [PMID: 34207489 PMCID: PMC8229977 DOI: 10.3390/ma14123163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 06/02/2021] [Accepted: 06/05/2021] [Indexed: 11/16/2022]
Abstract
Multilayer reduced graphene oxide (mrGO) was chemically modified by electroless plating of copper on surface to form mrGO-Cu. The scanning electron microscope (SEM) and transmission electron microscope (TEM) analysis revealed that nano-Cu particles were uniformly dispersed on the surface of mrGO. The mrGO-Cu powders were further utilized as reinforcements for aluminum (Al) matrix and the mrGO-Cu/Al composite was successfully fabricated through clad rolling of milled powder. The tribological properties of the mrGO-Cu/Al composites were explored. The tribological results show that the mrGO-Cu could reduce the friction coefficient and wear loss of mrGO-Cu/Al composites, since the mrGO-Cu participated in lubricating processes due to the formation of a transfer layer on the contact surface. Furthermore, it is found that the composition of mrGO-Cu could significantly influence the tribological properties of the mrGO-Cu/Al composites. The composites with 4% of mrGO-Cu for composites exhibited the best tribological behavior, which transformed from adhesive wear to abrasive wear, due to the formation of a graphite lubricating film.
Collapse
Affiliation(s)
- Fengguo Liu
- School of Materials and Metallurgy, Northeastern University, Shenyang 110004, China; (F.L.); (N.S.)
- School of Materials Science and Engineering, Shenyang Ligong University, Shenyang 110004, China
| | - Ning Su
- School of Materials and Metallurgy, Northeastern University, Shenyang 110004, China; (F.L.); (N.S.)
| | - Renguo Guan
- School of Materials and Metallurgy, Northeastern University, Shenyang 110004, China; (F.L.); (N.S.)
- Correspondence: ; Tel.: +86-24-8368-1463
| |
Collapse
|
40
|
Ultrasensitive molecularly imprinted fluorescence sensor for simultaneous determination of CA125 and CA15-3 in human serum and OVCAR-3 and MCF-7 cells lines using Cd and Ni nanoclusters as new emitters. Anal Bioanal Chem 2021; 413:4049-4061. [PMID: 34057557 DOI: 10.1007/s00216-021-03362-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 03/19/2021] [Accepted: 04/19/2021] [Indexed: 02/05/2023]
Abstract
In the clinical diagnosis of tumors, a single-marker immunoassay may lead to false results. Thus there is a need for an effective and valid method for the simultaneous measurement of multiple tumor markers. In this work, an efficient fluorescence immunosensor for the simultaneous measurement of CA125 and CA15-3 tumor markers was fabricated by utilizing the high selectivity of magnetic molecularly imprinted polymers (MMIPs) and the high sensitivity of a fluorescence (FL) method. Ni nanoclusters (Ni NCs) and noble Cd nanoclusters (Cd NCs) were introduced as efficient and economic emitters, and magnetic graphene oxide (GO-Fe3O4) was applied as a support material for surface molecularly imprinted polymers. Under the most favorable experimental conditions, the fluorescence intensity of the Cd NCs and Ni NCs gradually increased with increasing concentration of CA125 and CA15-3 antigens at a range of 0.0005-40 U mL-1, respectively, with a limit of detection (LOD) of 50 μU mL-1. The developed method had excellent properties including a broad linear range, good reproducibility, and simple operation for the clinical diagnosis of CA 125 and CA 15-3 tumor markers. This molecularly imprinted fluorescence sensor has the potential to be an effective clinical tool for the timely screening of breast cancer in human serum samples and OVCAR-3 and MCF-7 cell lines, and can be applied in clinical diagnostics.
Collapse
|
41
|
Biofunctionalization of Porous Ti Substrates Coated with Ag Nanoparticles for Potential Antibacterial Behavior. METALS 2021. [DOI: 10.3390/met11050692] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Ti prosthesis have shown better biological compatibility, mechanical performance, and resistance to corrosion in cases of bone replacements. Nevertheless, fully dense Ti in connection with bone-host tissues show stress-shielding phenomenon that, together with the development of frequent undesirable microbial infections, may lead to implant failures. To overcome these issues, the present study aimed at the development of a novel combination of a chemically functionalized porous Ti substrate with a potentially therapeutic AgNPs coating. Fully dense and porous Ti substrates (30 and 60 vol.%, 100–200 and 355–500 μm, as spacer particles) were studied. Ti surface was treated with acid or basic medium followed by silanization and deposition of AgNPs by “submerged” and “in situ” methods. In general, for similar porosity, mechanical resistance decreased as pore size increased. Acidic reagent and submerged methodology were the best combination for fully dense Ti substrates. Hence, they were also employed for porous Ti substrates. Depending on the porosity of the substrates, variations can be observed both in the size and degree of agglomeration of the deposited AgNPs, entailing differences in the antibacterial behavior of the samples.
Collapse
|
42
|
Wang H, He J, Ge L, Xu Z, Zhou W, Shao Z. Antiperovskite FeNNi2Co and FeNNi3 nanosheets as a non-enzymatic electrochemical sensor for highly sensitive detection of glucose. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
43
|
Kim SJ, Quan Y, Ha E, Shin W. Enhancement of Electrocatalytic Activity upon the Addition of Single Wall Carbon Nanotube to the Redox-hydrogel-based Glucose Sensor. J ELECTROCHEM SCI TE 2021. [DOI: 10.33961/jecst.2020.01039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
44
|
Chowdhury SR, Mukherjee P, Bhattacharya SK. A Highly Sensitive Nonenzymatic Glucose Sensor Based on Carbon Electrode Amplified with Pd
x
Cu
y
Catalyst. ELECTROANAL 2021. [DOI: 10.1002/elan.202060268] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Sreya Roy Chowdhury
- Physical Chemistry Section Department of Chemistry Jadavpur University Kolkata 700032 India
| | | | | |
Collapse
|
45
|
Fernández I, González-Mora JL, Lorenzo-Luis P, Villalonga R, Salazar-Carballo PA. Nickel oxide nanoparticles-modified glassy carbon electrodes for non-enzymatic determination of total sugars in commercial beverages. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105538] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
46
|
Wang L, Liu Y, Yang R, Li J, Qu L. AgNPs–PDA–GR nanocomposites-based molecularly imprinted electrochemical sensor for highly recognition of 2,4,6-trichlorophenol. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105567] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
47
|
Zhu T, Wang X, Chang W, Zhang Y, Maruyama T, Luo L, Zhao X. Green fabrication of Cu/rGO decorated SWCNT buckypaper as a flexible electrode for glucose detection. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 120:111757. [PMID: 33545898 DOI: 10.1016/j.msec.2020.111757] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 10/27/2020] [Accepted: 11/21/2020] [Indexed: 12/17/2022]
Abstract
As a paper-like membrane composed of single-walled carbon nanotube (SWCNT), buckypaper possesses high conductivity, ideal flexibility, large surface area, great thermal/chemical stability and biocompatibility, which has manifested its potential as an alternative support material. However, due to the lack of defects, high quality SWCNT synthesized by arc-discharge method is difficult to be modified with metal nanoparticles for electro-catalysis. In this paper, a novel green strategy has been developed to fabricate SWCNT buckypaper decorated with Cu/reduced graphene oxide (Cu/rGO-BP) for the first time, in which graphene oxide functions as the intermediate between SWCNT and Cu nanoparticles. The fabricated Cu/rGO-BP was applied as a flexible electrode for electrochemical glucose detection. The electrode exhibited excellent electro-catalytic activity for glucose oxidation. The sensor based on Cu/rGO-BP performed a high upper limit of linear range (25 mM), which is close to commercial glucose sensors. The proposed strategy for Cu/rGO-BP fabrication can be extended to modify buckypaper with other metal or metal oxide nanoparticles, and thus opens an innovative route to potential practical applications of flexible buckypaper in wearable bioelectronics.
Collapse
Affiliation(s)
- Tianxiang Zhu
- Department of Physics, Shanghai University, Shanghai 200444, China; Institute of Low-dimensional Carbons and Device Physics, Shanghai University, Shanghai 200444, China
| | - Xiaoer Wang
- Department of Physics, Shanghai University, Shanghai 200444, China; Institute of Low-dimensional Carbons and Device Physics, Shanghai University, Shanghai 200444, China
| | - Weiwei Chang
- Department of Physics, Shanghai University, Shanghai 200444, China; Institute of Low-dimensional Carbons and Device Physics, Shanghai University, Shanghai 200444, China
| | - Yifan Zhang
- Department of Physics, Shanghai University, Shanghai 200444, China; Institute of Low-dimensional Carbons and Device Physics, Shanghai University, Shanghai 200444, China
| | - Takahiro Maruyama
- Department of Applied Chemistry, Meijo University, Nagoya 468-8502, Japan
| | - Liqiang Luo
- Department of Chemistry, Shanghai University, Shanghai 200444, China.
| | - Xinluo Zhao
- Department of Physics, Shanghai University, Shanghai 200444, China; Institute of Low-dimensional Carbons and Device Physics, Shanghai University, Shanghai 200444, China.
| |
Collapse
|
48
|
Graphene and Perovskite-Based Nanocomposite for Both Electrochemical and Gas Sensor Applications: An Overview. SENSORS 2020; 20:s20236755. [PMID: 33255958 PMCID: PMC7731062 DOI: 10.3390/s20236755] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 11/18/2020] [Accepted: 11/22/2020] [Indexed: 01/16/2023]
Abstract
Perovskite and graphene-based nanocomposites have attracted much attention and been proven as promising candidates for both gas (H2S and NH3) and electrochemical (H2O2, CH3OH and glucose) sensor applications. In this review, the development of portable sensor devices on the sensitivity, selectivity, cost effectiveness, and electrode stability of chemical and electrochemical applications is summarized. The authors are mainly focused on the common analytes in gas sensors such as hydrogen sulfide, ammonia, and electrochemical sensors including non-enzymatic glucose, hydrazine, dopamine, and hydrogen peroxide. Finally, the article also addressed the stability of composite performance and outlined recent strategies for future sensor perspectives.
Collapse
|
49
|
Ayranci R. The Rapid and Practical Route to Cu@PCR Sensor: Modification of Copper Nanoparticles Upon Conducting Polymer for a Sensitive Non‐Enzymatic Glucose Sensor. ELECTROANAL 2020. [DOI: 10.1002/elan.202060287] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Rukiye Ayranci
- Department of Labarotory Technology University of Dumlupinar Simav 43500 Kutahya Turkey
| |
Collapse
|
50
|
Güney S, Arslan T, Yanık S, Güney O. An Electrochemical Sensing Platform Based on Graphene Oxide and Molecularly Imprinted Polymer Modified Electrode for Selective Detection of Amoxicillin. ELECTROANAL 2020. [DOI: 10.1002/elan.202060129] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Sevgi Güney
- Department of Chemistry Istanbul Technical University 34469, Maslak Istanbul Turkey
| | - Taner Arslan
- Department of Chemistry Istanbul Technical University 34469, Maslak Istanbul Turkey
| | - Serhat Yanık
- Department of Metallurgical and Materials Engineering Marmara University, Kadıkoy Istanbul 34722 Turkey
| | - Orhan Güney
- Department of Chemistry Istanbul Technical University 34469, Maslak Istanbul Turkey
| |
Collapse
|