1
|
Xie F. Natural polymer starch-based materials for flexible electronic sensor development: A review of recent progress. Carbohydr Polym 2024; 337:122116. [PMID: 38710566 DOI: 10.1016/j.carbpol.2024.122116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/11/2024] [Accepted: 03/30/2024] [Indexed: 05/08/2024]
Abstract
In response to the burgeoning interest in the development of highly conformable and resilient flexible electronic sensors capable of transducing diverse physical stimuli, this review investigates the pivotal role of natural polymers, specifically those derived from starch, in crafting sustainable and biocompatible sensing materials. Expounding on cutting-edge research, the exploration delves into innovative strategies employed to leverage the distinctive attributes of starch in conjunction with other polymers for the fabrication of advanced sensors. The comprehensive discussion encompasses a spectrum of starch-based materials, spanning all-starch-based gels to starch-based soft composites, meticulously scrutinizing their applications in constructing resistive, capacitive, piezoelectric, and triboelectric sensors. These intricately designed sensors exhibit proficiency in detecting an array of stimuli, including strain, temperature, humidity, liquids, and enzymes, thereby playing a pivotal role in the continuous and non-invasive monitoring of human body motions, physiological signals, and environmental conditions. The review highlights the intricate interplay between material properties, sensor design, and sensing performance, emphasizing the unique advantages conferred by starch-based materials, such as self-adhesiveness, self-healability, and re-processibility facilitated by dynamic bonding. In conclusion, the paper outlines current challenges and future research opportunities in this evolving field, offering valuable insights for prospective investigations.
Collapse
Affiliation(s)
- Fengwei Xie
- Department of Chemical Engineering, University of Bath, Bath BA2 7AY, United Kingdom.
| |
Collapse
|
2
|
Bounegru AV, Iticescu C, Georgescu LP, Apetrei C. Development of an Innovative Biosensor Based on Graphene/PEDOT/Tyrosinase for the Detection of Phenolic Compounds in River Waters. Int J Mol Sci 2024; 25:4419. [PMID: 38674004 PMCID: PMC11049897 DOI: 10.3390/ijms25084419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/02/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
Phenolic compounds, originating from industrial, agricultural, and urban sources, can leach into flowing waters, adversely affecting aquatic life, biodiversity, and compromising the quality of drinking water, posing potential health hazards to humans. Thus, monitoring and mitigating the presence of phenolic compounds in flowing waters are essential for preserving ecosystem integrity and safeguarding public health. This study explores the development and performance of an innovative sensor based on screen-printed electrode (SPE) modified with graphene (GPH), poly(3,4-ethylenedioxythiophene) (PEDOT), and tyrosinase (Ty), designed for water analysis, focusing on the manufacturing process and the obtained electroanalytical results. The proposed biosensor (SPE/GPH/PEDOT/Ty) was designed to achieve a high level of precision and sensitivity, as well as to allow efficient analytical recoveries. Special attention was given to the manufacturing process and optimization of the modifying elements' composition. This study highlights the potential of the biosensor as an efficient and reliable solution for water analysis. Modification with graphene, the synthesis and electropolymerization deposition of the PEDOT polymer, and tyrosinase immobilization contributed to obtaining a high-performance and robust biosensor, presenting promising perspectives in monitoring the quality of the aquatic environment. Regarding the electroanalytical experimental results, the detection limits (LODs) obtained with this biosensor are extremely low for all phenolic compounds (8.63 × 10-10 M for catechol, 7.72 × 10-10 M for 3-methoxycatechol, and 9.56 × 10-10 M for 4-methylcatechol), emphasizing its ability to accurately measure even subtle variations in the trace compound parameters. The enhanced sensitivity of the biosensor facilitates detection and quantification in river water samples. Analytical recovery is also an essential aspect, and the biosensor presents consistent and reproducible results. This feature significantly improves the reliability and usefulness of the biosensor in practical applications, making it suitable for monitoring industrial or river water.
Collapse
Affiliation(s)
| | | | | | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galati, 47 Domneasca Street, 800008 Galați, Romania; (A.V.B.); (C.I.)
| |
Collapse
|
3
|
Hyder A, Ali A, Buledi JA, Memon AA, Iqbal M, Bangalni TH, Solangi AR, Thebo KH, Akhtar J. Nanodiamonds: A Cutting-Edge Approach to Enhancing Biomedical Therapies and Diagnostics in Biosensing. CHEM REC 2024; 24:e202400006. [PMID: 38530037 DOI: 10.1002/tcr.202400006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 02/25/2024] [Indexed: 03/27/2024]
Abstract
Nanodiamonds (NDs) have garnered attention in the field of nanomedicine due to their unique properties. This review offers a comprehensive overview of NDs synthesis methods, properties, and their uses in biomedical applications. Various synthesis techniques, such as detonation, high-pressure, high-temperature, and chemical vapor deposition, offer distinct advantages in tailoring NDs' size, shape, and surface properties. Surface modification methods further enhance NDs' biocompatibility and enable the attachment of bioactive molecules, expanding their applicability in biological systems. NDs serve as promising nanocarriers for drug delivery, showcasing biocompatibility and the ability to encapsulate therapeutic agents for targeted delivery. Additionally, NDs demonstrate potential in cancer treatment through hyperthermic therapy and vaccine enhancement for improved immune responses. Functionalization of NDs facilitates their utilization in biosensors for sensitive biomolecule detection, aiding in precise diagnostics and rapid detection of infectious diseases. This review underscores the multifaceted role of NDs in advancing biomedical applications. By synthesizing NDs through various methods and modifying their surfaces, researchers can tailor their properties for specific biomedical needs. The ability of NDs to serve as efficient drug delivery vehicles holds promise for targeted therapy, while their applications in hyperthermic therapy and vaccine enhancement offer innovative approaches to cancer treatment and immunization. Furthermore, the integration of NDs into biosensors enhances diagnostic capabilities, enabling rapid and sensitive detection of biomolecules and infectious diseases. Overall, the diverse functionalities of NDs underscore their potential as valuable tools in nanomedicine, paving the way for advancements in healthcare and biotechnology.
Collapse
Affiliation(s)
- Ali Hyder
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Akbar Ali
- State Key Laboratory of Multi-phase Complex Systems, Institute of Process Engineering (IPE), Chinese Academy of Sciences, Beijing, 100F190, China
- University of the Chinese Academy of Sciences, 19 A Yuquan Road, Beijing, 100049, China
| | - Jamil A Buledi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Ayaz Ali Memon
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Muzaffar Iqbal
- Department of Chemistry, Faculty of Physical and Applied Sciences, The University of Haripur KPK, Haripur, 22620, Pakistan
| | - Talib Hussain Bangalni
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Amber R Solangi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
| | - Khalid Hussain Thebo
- Institute of Metal Research (IMR), Chinese Academy of Science, 2 Wenhua Rood, Shenyang, China
- Department of Chemistry Mirpur, University of Science and Technology (MUST), 10250 (AJK), Mirpur, Pakistan
| | - Javeed Akhtar
- Department of Chemistry Mirpur, University of Science and Technology (MUST), 10250 (AJK), Mirpur, Pakistan
| |
Collapse
|
4
|
Srivastava A, Azad UP. Nanobioengineered surface comprising carbon based materials for advanced biosensing and biomedical application. Int J Biol Macromol 2023; 253:126802. [PMID: 37690641 DOI: 10.1016/j.ijbiomac.2023.126802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/30/2023] [Accepted: 09/06/2023] [Indexed: 09/12/2023]
Abstract
Carbon-based nanomaterials (CNMs) are at the cutting edge of materials science. Due to their distinctive architectures, substantial surface area, favourable biocompatibility, and reactivity to internal and/or external chemico-physical stimuli, carbon-based nanomaterials are becoming more and more significant in a wide range of applications. Numerous research has been conducted and still is going on to investigate the potential uses of carbon-based hybrid materials for diverse applications such as biosensing, bioimaging, smart drug delivery with the potential for theranostic or combinatorial therapies etc. This review is mainly focused on the classifications and synthesis of various types of CNMs and their electroanalytical application for development of efficient and ultra-sensitive electrochemical biosensors for the point of care diagnosis of fatal and severe diseases at their very initial stage. This review is mainly focused on the classification, synthesis and application of carbon-based material for biosensing applications. The integration of various types of CNMs with nanomaterials, enzymes, redox mediators and biomarkers have been used discussed in development of smart biosensing platform. We have also made an effort to discuss the future prospects for these CNMs in the biosensing area as well as the most recent advancements and applications which will be quite useful for the researchers working across the globe working specially in biosensors field.
Collapse
Affiliation(s)
- Ananya Srivastava
- Department of Chemistry, Banaras Hindu University, Varanasi 221005, Uttar Pradesh, India.
| | - Uday Pratap Azad
- Laboratory of Nanoelectrochemistry, Department of Chemistry, Guru Ghasidas Vishwavidyalaya (Central University), Bilaspur 495 009, CG, India.
| |
Collapse
|
5
|
Zandieh M, Liu J. Metal-Mediated DNA Adsorption on Carboxylated, Hydroxylated, and Hydrogenated Nanodiamonds. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:11596-11602. [PMID: 37552885 DOI: 10.1021/acs.langmuir.3c01066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/10/2023]
Abstract
Nanodiamonds (NDs) have attracted considerable attention owing to their quantum properties and versatility in biological applications. In this study, we systematically investigated the adsorption of DNA oligonucleotides onto NDs with three types of surface groups: carboxylated (COOH-), hydroxylated (OH-), and hydrogenated (H-). Among them, only the H-NDs showed fluorescence quenching property that is useful for real-time DNA adsorption kinetic studies. The effect of common metal ions on DNA adsorption was studied. In the presence of Na+, the order of DNA adsorption efficiency was H- > OH- > COOH-, whereas all the NDs showed a similar DNA adsorption efficiency in the presence of divalent metal ions such as Ca2+ and Zn2+. Desorption studies revealed that hydrogen bonding and metal-mediated interactions were dominant for the adsorption of DNA, and the H-NDs exhibited extraordinarily tight DNA adsorption. Finally, a fluorescently labeled DNA was adsorbed on NDs for DNA detection, and the COOH-NDs had the highest target specificity, and a detection limit of 1.4 nM was achieved. This study indicates the feasibility of using metal ions to mediate the physical adsorption of DNA to NDs and compares various NDs with graphene oxide for fundamental understanding.
Collapse
Affiliation(s)
- Mohamad Zandieh
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Juewen Liu
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
6
|
Kilic NM, Singh S, Keles G, Cinti S, Kurbanoglu S, Odaci D. Novel Approaches to Enzyme-Based Electrochemical Nanobiosensors. BIOSENSORS 2023; 13:622. [PMID: 37366987 DOI: 10.3390/bios13060622] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 05/29/2023] [Accepted: 06/01/2023] [Indexed: 06/28/2023]
Abstract
Electrochemistry is a genuinely interdisciplinary science that may be used in various physical, chemical, and biological domains. Moreover, using biosensors to quantify biological or biochemical processes is critical in medical, biological, and biotechnological applications. Nowadays, there are several electrochemical biosensors for various healthcare applications, such as for the determination of glucose, lactate, catecholamines, nucleic acid, uric acid, and so on. Enzyme-based analytical techniques rely on detecting the co-substrate or, more precisely, the products of a catalyzed reaction. The glucose oxidase enzyme is generally used in enzyme-based biosensors to measure glucose in tears, blood, etc. Moreover, among all nanomaterials, carbon-based nanomaterials have generally been utilized thanks to the unique properties of carbon. The sensitivity can be up to pM levels using enzyme-based nanobiosensor, and these sensors are very selective, as all enzymes are specific for their substrates. Furthermore, enzyme-based biosensors frequently have fast reaction times, allowing for real-time monitoring and analyses. These biosensors, however, have several drawbacks. Changes in temperature, pH, and other environmental factors can influence the stability and activity of the enzymes, affecting the reliability and repeatability of the readings. Additionally, the cost of the enzymes and their immobilization onto appropriate transducer surfaces might be prohibitively expensive, impeding the large-scale commercialization and widespread use of biosensors. This review discusses the design, detection, and immobilization techniques for enzyme-based electrochemical nanobiosensors, and recent applications in enzyme-based electrochemical studies are evaluated and tabulated.
Collapse
Affiliation(s)
- Nur Melis Kilic
- Faculty of Science Biochemistry Department, Ege University, 35100 Bornova, Turkey
| | - Sima Singh
- Department of Pharmacy, University of Naples Federico II, 80138 Naples, Italy
| | - Gulsu Keles
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey
| | - Stefano Cinti
- Department of Pharmacy, University of Naples Federico II, 80138 Naples, Italy
| | - Sevinc Kurbanoglu
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, 06560 Ankara, Turkey
| | - Dilek Odaci
- Faculty of Science Biochemistry Department, Ege University, 35100 Bornova, Turkey
| |
Collapse
|
7
|
Bounegru AV, Apetrei C. Tyrosinase Immobilization Strategies for the Development of Electrochemical Biosensors-A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:760. [PMID: 36839128 PMCID: PMC9962745 DOI: 10.3390/nano13040760] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 02/11/2023] [Accepted: 02/15/2023] [Indexed: 06/18/2023]
Abstract
The development of enzyme biosensors has successfully overcome various challenges such as enzyme instability, loss of enzyme activity or long response time. In the electroanalytical field, tyrosinase is used to develop biosensors that exploit its ability to catalyze the oxidation of numerous types of phenolic compounds with antioxidant and neurotransmitter roles. This review critically examines the main tyrosinase immobilization techniques for the development of sensitive electrochemical biosensors. Immobilization strategies are mainly classified according to the degree of reversibility/irreversibility of enzyme binding to the support material. Each tyrosinase immobilization method has advantages and limitations, and its selection depends mainly on the type of support electrode, electrode-modifying nanomaterials, cross-linking agent or surfactants used. Tyrosinase immobilization by cross-linking is characterized by very frequent use with outstanding performance of the developed biosensors. Additionally, research in recent years has focused on new immobilization strategies involving cross-linking, such as cross-linked enzyme aggregates (CLEAs) and magnetic cross-linked enzyme aggregates (mCLEAs). Therefore, it can be considered that cross-linking immobilization is the most feasible and economical approach, also providing the possibility of selecting the reagents used and the order of the immobilization steps, which favor the enhancement of biosensor performance characteristics.
Collapse
|
8
|
Zhang Y, Wang Y, Dong Y, Zhang Z, Hasebe Y, Zhu J, Liu Z, Gao E. Effect of Acridine Orange on Improving the Electrochemical Performance of Tyrosinase Adsorbed Sulfide Minerals Based Catechol Biosensor. ChemistrySelect 2023. [DOI: 10.1002/slct.202202444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Yan Zhang
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech Zone Anshan Liaoning 114051 China
| | - Yue Wang
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech Zone Anshan Liaoning 114051 China
| | - Yan Dong
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech Zone Anshan Liaoning 114051 China
| | - Zhiqiang Zhang
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech Zone Anshan Liaoning 114051 China
| | - Yasushi Hasebe
- Department of Life Science and Green Chemistry Faculty of Engineering Saitama Institute of Technology 1690 Fusaiji Fukaya Saitama 369-0293 Japan
| | - Jianmin Zhu
- Oxiranchem Holding Group Inc. No. 29 Donghuan Road, Hongwei District Liaoyang Liaoning China
| | - Zhaobin Liu
- Oxiranchem Holding Group Inc. No. 29 Donghuan Road, Hongwei District Liaoyang Liaoning China
| | - Enjun Gao
- School of Chemical Engineering University of Science and Technology Liaoning 185 Qianshan Middle Road, High-tech Zone Anshan Liaoning 114051 China
| |
Collapse
|
9
|
Liu Y, Chen Y, Fan Y, Gao G, Zhi J. Development of a Tyrosinase Amperometric Biosensor Based on Carbon Nanomaterials for the Detection of Phenolic Pollutants in Diverse Environments. ChemElectroChem 2022. [DOI: 10.1002/celc.202200861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Yanran Liu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Yafei Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Yining Fan
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Guanyue Gao
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| | - Jinfang Zhi
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials Technical Institute of Physics and Chemistry Chinese Academy of Sciences Beijing 100190 PR China
- University of Chinese Academy of Sciences Beijing 100049 PR China
| |
Collapse
|
10
|
Enzyme Immobilized Nanomaterials: An Electrochemical Bio-Sensing and Biocatalytic Degradation Properties Toward Organic Pollutants. Top Catal 2022. [DOI: 10.1007/s11244-022-01760-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
11
|
Vasudevan M, Perumal V, Karuppanan S, Ovinis M, Bothi Raja P, Gopinath SCB, Immanuel Edison TNJ. A Comprehensive Review on Biopolymer Mediated Nanomaterial Composites and Their Applications in Electrochemical Sensors. Crit Rev Anal Chem 2022:1-24. [PMID: 36288094 DOI: 10.1080/10408347.2022.2135090] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Biopolymers are an attractive green alternative to conventional polymers, owing to their excellent biocompatibility and biodegradability. However, their amorphous and nonconductive nature limits their potential as active biosensor material/substrate. To enhance their bio-analytical performance, biopolymers are combined with conductive materials to improve their physical and chemical characteristics. We review the main advances in the field of electrochemical biosensors, specifically the structure, approach, and application of biopolymers, as well as their conjugation with conductive nanoparticles, polymers and metal oxides in green-based noninvasive analytical biosensors. In addition, we reviewed signal measurement, substrate bio-functionality, biochemical reaction, sensitivity, and limit of detection (LOD) of different biopolymers on various transducers. To date, pectin biopolymer, when conjugated with either gold nanoparticles, polypyrrole, reduced graphene oxide, or multiwall carbon nanotubes forming nanocomposites on glass carbon electrode transducer, tends to give the best LOD, highest sensitivity and can detect multiple analytes/targets. This review will spur new possibilities for the use of biosensors for medical diagnostic tests.
Collapse
Affiliation(s)
- Mugashini Vasudevan
- Centre of Innovative Nanostructures and Nanodevices (COINN), Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Veeradasan Perumal
- Centre of Innovative Nanostructures and Nanodevices (COINN), Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Saravanan Karuppanan
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Mark Ovinis
- School of Engineering and the Built Environment, Birmingham City University, Birmingham, UK
| | - Pandian Bothi Raja
- School of Chemical Sciences, Universiti Sains Malaysia, Penang, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Kangar 01000 & Faculty of Chemical Engineering & Technology, Arau 02600, Universiti Malaysia Perlis, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), Arau 02600, Pauh Campus, Perlis, Malaysia
| | | |
Collapse
|
12
|
Vicentini FC, Silva LRG, Stefano JS, Lima ARF, Prakash J, Bonacin JA, Janegitz BC. Starch-Based Electrochemical Sensors and Biosensors: A Review. BIOMEDICAL MATERIALS & DEVICES 2022. [PMCID: PMC9510496 DOI: 10.1007/s44174-022-00012-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Natural green compounds for sensor modification (binders) are challenging in electrochemistry. Starch is a carbohydrate biopolymer that has been used extensively in the development of biomaterials for the food industry due to its ability to impart textural characteristics and provide gelling or film formation. In particular, the excellent film-forming characteristics have been used for the development of new surface modifying architectures for electrodes. Here, we highlight a very comprehensive overview of the properties of interest of various types of starch in conjunction with (bio)materials in the chemical modification of sensors and biosensors. Throughout the review, we first give an introduction to the extraction, applications, and properties of starches followed by an overview of the prospects and their possible applications in electrochemical sensors and biosensors. In this context, we discuss some important characteristics of starches and different strategies of their film formation with an emphasis on their role in the development of electrochemical sensors and biosensors highlighting their main contributions to enhancing the performance of these devices and their applications in environmental and clinical samples.
Collapse
Affiliation(s)
- Fernando C. Vicentini
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, Buri, SP 18290-000 Brazil
| | - Luiz R. G. Silva
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| | - Jéssica S. Stefano
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| | - Alan R. F. Lima
- Center of Nature Sciences, Federal University of São Carlos, Rod. Lauri Simões de Barros km 12, Buri, SP 18290-000 Brazil
| | - Jai Prakash
- Department of Chemistry, National Institute of Technology Hamirpur, Hamirpur, Himachal Pradesh 177005 India
| | - Juliano A. Bonacin
- Institute of Chemistry, University of Campinas (UNICAMP), Campinas, São Paulo 13083-859 Brazil
| | - Bruno C. Janegitz
- Laboratory of Sensors, Nanomedicine, and Nanostructured Materials (LSNano), Federal University of São Carlos, Araras, São Paulo 13600-970 Brazil
| |
Collapse
|
13
|
Recent innovations in bionanocomposites-based food packaging films – A comprehensive review. Food Packag Shelf Life 2022. [DOI: 10.1016/j.fpsl.2022.100877] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
14
|
Özer EM, Apetrei RM, Camurlu P. Trace-level phenolics detection based on composite PAN-MWCNTs nanofibers. Chembiochem 2022; 23:e202200139. [PMID: 35775384 DOI: 10.1002/cbic.202200139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 06/29/2022] [Indexed: 11/10/2022]
Abstract
In view of major concerns regarding toxicity (genotoxic, mutagenic, hepatotoxic) of phenolics, there is an on-going necessity for sensitive and accurate analytical procedures for detection and measurements in environmental field, water, and food quality control. The current study proposes composite polyacrylonitrile nanofibrous assemblies enriched with multi-wall carbon nanotubes (PAN-MWCNTs NFs) as suitable immobilization platforms for cross-linking of Tyrosinase in detection of both diphenols and monophenols, which are of much interest in water contamination.
Collapse
Affiliation(s)
- Elif Merve Özer
- Akdeniz Üniversitesi: Akdeniz Universitesi, Chemistry, TURKEY
| | | | - Pinar Camurlu
- Akdeniz University: Akdeniz Universitesi, Department of Chemistry, Akdeniz University Department of Chemistry, 07058, Antalya, TURKEY
| |
Collapse
|
15
|
Medyantseva EP, Beilinson RM, Nikolaenko AI, Budnikov HC. Horseradish Peroxidase: Analytical Capabilities in the Determination of Zearalenone. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822060090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Du Y, Wang B, Kang K, Ji X, Wang L, Zhao W, Ren J. Signal synergistic amplification strategy based on functionalized CeMOFs for highly sensitive electrochemical detection of phenolic isomers. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107285] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
17
|
Neven L, Barich H, Sleegers N, Cánovas R, Debruyne G, De Wael K. Development of a combi-electrosensor for the detection of phenol by combining photoelectrochemistry and square wave voltammetry. Anal Chim Acta 2022; 1206:339732. [DOI: 10.1016/j.aca.2022.339732] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 03/08/2022] [Accepted: 03/14/2022] [Indexed: 11/27/2022]
|
18
|
Mirzaei F, Valizadeh H, Pazhang M. Immobilization of papain on nitrogen-doped graphene quantum dots improves the enzymatic properties and makes it a biosensor for cystatin C. Process Biochem 2022. [DOI: 10.1016/j.procbio.2022.04.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
19
|
Recent advances in carbon nanomaterials-based electrochemical sensors for phenolic compounds detection. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106776] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
20
|
Bilal M, Cheng H, González-González RB, Parra-Saldívar R, Iqbal HM. Bio-applications and biotechnological applications of nanodiamonds. JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY 2021. [DOI: 10.1016/j.jmrt.2021.11.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
21
|
Attaallah R, Amine A. The Kinetic and Analytical Aspects of Enzyme Competitive Inhibition: Sensing of Tyrosinase Inhibitors. BIOSENSORS 2021; 11:322. [PMID: 34562912 PMCID: PMC8471001 DOI: 10.3390/bios11090322] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 08/27/2021] [Accepted: 09/02/2021] [Indexed: 11/17/2022]
Abstract
An amperometric biosensor based on tyrosinase, immobilized onto a carbon black paste electrode using glutaraldehyde and BSA was constructed to detect competitive inhibitors. Three inhibitors were used in this study: benzoic acid, sodium azide, and kojic acid, and the obtained values for fifty percent of inhibition (IC50) were 119 µM, 1480 µM, and 30 µM, respectively. The type of inhibition can also be determined from the curve of the degree of inhibition by considering the shift of the inhibition curves. Amperometric experiments were performed with a biosensor polarized at the potential -0.15 V vs. Ag/AgCl and using 0.1 M phosphate buffer (pH 6.8) as an electrolyte. Under optimized conditions, the proposed biosensor showed a linear amperometric response toward catechol detection from 0.5 µM to 38 µM with a detection limit of 0.35 µM (S/N = 3), and its sensitivity was 66.5 mA M-1 cm-2. Moreover, the biosensor exhibited a good storage stability. Conversely, a novel graphical plot for the determination of reversible competitive inhibition was represented for free tyrosinase. The graph consisted of plotting the half-time reaction (t1/2) as a function of the inhibitor concentration at various substrate concentrations. This innovative method relevance was demonstrated in the case of kojic acid using a colorimetric bioassay relying on tyrosinase inhibition. The results showed that the t1/2 provides an extended linear range of tyrosinase inhibitors.
Collapse
Affiliation(s)
| | - Aziz Amine
- Laboratory of Process Engineering & Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, PA 146, Mohammedia 20800, Morocco;
| |
Collapse
|
22
|
Yang M, Guo H, Sun L, Wu N, Wang M, Yang F, Zhang T, Zhang J, Pan Z, Yang W. Simultaneous electrochemical detection of hydroquinone and catechol using MWCNT-COOH/CTF-1 composite modified electrode. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.126917] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
23
|
Bakirhan NK, Kaya SI, Jabbarov R, Gahramanova G, Abdullayeva S, Dedeoglu A, Ozkan CK, Savaser A, Ozkan Y, Ozkan SA. The Power of Carbon Nanotubes on Sensitive Drug Determination Methods. Crit Rev Anal Chem 2021; 53:374-383. [PMID: 34334078 DOI: 10.1080/10408347.2021.1958296] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Nowadays, carbon nanotubes (CNTs) due to their inorganic conducting, semiconducting, and organic π-π stacking properties are becoming innovative materials. CNTs have an adjustable size, large surface area, and other significant chemical properties. Due to their excellent electrical, optical, and mechanical properties, CNTs play an important role in various application fields. In the past decade, many unique intrinsic physical and chemical properties have been intensively explored for pharmaceutical, biological, and biomedical applications. The functionalization of CNTs results in a remarkably reduced cytotoxicity and at the same time increased biocompatibility. The toxicity studies reveal that highly water-soluble and serum stable nanotubes are biocompatible, nontoxic, and potentially useful for biomedical applications. Ultrasensitive drug determination from its dosage form and/or biological samples with carbon nanotubes can be realized after surface modification. The main purpose of this review is to present recent achievements on CNTs which are investigated in electrochemical and chromatographically sensing technologies.
Collapse
Affiliation(s)
- Nurgul K Bakirhan
- Gulhane Faculty of Pharmacy, Department of Analytical Chemistry, University of Health Sciences, Ankara, Turkey
| | - S Irem Kaya
- Gulhane Faculty of Pharmacy, Department of Analytical Chemistry, University of Health Sciences, Ankara, Turkey.,Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| | - Rasim Jabbarov
- Institute of Physics, Azerbaijan National Academy of Sciences, Baku, Azerbaijan.,Research and Development Center for High Technologies, Ministry of Transport, Communication and High Technologies of Azerbaijan Republic, Baku, Azerbaijan
| | - Gulnaz Gahramanova
- Institute of Physics, Azerbaijan National Academy of Sciences, Baku, Azerbaijan.,Research and Development Center for High Technologies, Ministry of Transport, Communication and High Technologies of Azerbaijan Republic, Baku, Azerbaijan
| | - Sevda Abdullayeva
- Institute of Physics, Azerbaijan National Academy of Sciences, Baku, Azerbaijan.,Research and Development Center for High Technologies, Ministry of Transport, Communication and High Technologies of Azerbaijan Republic, Baku, Azerbaijan
| | - Aylin Dedeoglu
- Knowledge, Innovation and Technology Transfer Office, Başkent University, Ankara, Turkey
| | - Cansel Kose Ozkan
- Gulhane Faculty of Pharmacy, Department of Pharmaceutical Technology, University of Health Sciences, Ankara, Turkey
| | - Ayhan Savaser
- Gulhane Faculty of Pharmacy, Department of Pharmaceutical Technology, University of Health Sciences, Ankara, Turkey
| | - Yalcin Ozkan
- Gulhane Faculty of Pharmacy, Department of Pharmaceutical Technology, University of Health Sciences, Ankara, Turkey
| | - Sibel A Ozkan
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| |
Collapse
|
24
|
Hussain A, Rafeeq H, Qasim M, Jabeen Z, Bilal M, Franco M, Iqbal HMN. Engineered tyrosinases with broadened bio-catalysis scope: immobilization using nanocarriers and applications. 3 Biotech 2021; 11:365. [PMID: 34290948 PMCID: PMC8257883 DOI: 10.1007/s13205-021-02913-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/28/2021] [Indexed: 02/08/2023] Open
Abstract
Enzyme immobilization is a widely used technology for creating more stable, active, and reusable biocatalysts. The immobilization process also improves the enzyme's operating efficiency in industrial applications. Various support matrices have been designed and developed to enhance the biocatalytic efficiency of immobilized enzymes. Given their unique physicochemical attributes, including substantial surface area, rigidity, semi-conductivity, high enzyme loading, hyper catalytic activity, and size-assisted optical properties, nanomaterials have emerged as fascinating matrices for enzyme immobilization. Tyrosinase is a copper-containing monooxygenase that catalyzes the o-hydroxylation of monophenols to catechols and o-quinones. This enzyme possesses a wide range of uses in the medical, biotechnological, and food sectors. This article summarizes an array of nanostructured materials as carrier matrices for tyrosinase immobilization. Following a detailed background overview, various nanomaterials, as immobilization support matrices, including carbon nanotubes (CNTs), carbon dots (CDs), carbon black (CB), nanofibers, Graphene nanocomposite, platinum nanoparticles, nano-sized magnetic particles, lignin nanoparticles, layered double hydroxide (LDH) nanomaterials, gold nanoparticles (AuNPs), and zinc oxide nanoparticles have been discussed. Next, applied perspectives have been spotlights with particular reference to environmental pollutant sensing, phenolic compounds detection, pharmaceutical, and food industry (e.g., cereal processing, dairy processing, and meat processing), along with other miscellaneous applications.
Collapse
Affiliation(s)
- Asim Hussain
- grid.414839.30000 0001 1703 6673Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Hamza Rafeeq
- grid.414839.30000 0001 1703 6673Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Qasim
- grid.411727.60000 0001 2201 6036International Islamic University Islamabad, Islamabad, Pakistan
| | - Zara Jabeen
- grid.414839.30000 0001 1703 6673Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Bilal
- grid.417678.b0000 0004 1800 1941School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huai’an, 223003 China
| | - Marcelo Franco
- grid.412324.20000 0001 2205 1915Departament of Exact Sciences and Technology, State University of Santa Cruz, Ilhéus, Brazil
| | - Hafiz M. N. Iqbal
- grid.419886.a0000 0001 2203 4701Tecnologico de Monterrey, School of Engineering and Sciences, 64849 Monterrey, Mexico
| |
Collapse
|
25
|
Öndeş B, Evli S, Uygun M, Aktaş Uygun D. Boron nitride nanosheet modified label-free electrochemical immunosensor for cancer antigen 125 detection. Biosens Bioelectron 2021; 191:113454. [PMID: 34171737 DOI: 10.1016/j.bios.2021.113454] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 06/11/2021] [Accepted: 06/15/2021] [Indexed: 01/01/2023]
Abstract
In this presented study, a new boron nitride nanosheets modified label-free electrochemical immunosensors were prepared for early detection of cancer antigen 125 (CA125). To aim for, boron nitride (BN) nanosheets were synthesized by conventional sonication-assisted method and then characterized. BN nanosheets were used for the surface modification of the working electrode of the screen-printed electrode (SPE). Anti CA125 antibody was then directly immobilized onto the electrode surface due to its natural affinity towards BN nanosheets. Modified electrodes were blocked with BSA and finally protected with Nafion. The newly synthesized label-free immunosensor demonstrated good detection properties to CA125 with a linear range of 5-100 U and a detection limit of 1.18 U/mL. The developed immunosensor also showed excellent reproducibility, selectivity, and stability profiles. Additionally, this immunosensor was successfully used for the detection of CA125 in artificial human serum samples along with the interfering agents. Also, it is expected that the prepared immunosensor should carry the good potential for point-of-care diagnosis in real cases.
Collapse
Affiliation(s)
- Baha Öndeş
- Adnan Menderes University, Faculty of Science and Arts, Department of Chemistry, Aydın, Turkey
| | - Sinem Evli
- Adnan Menderes University, Faculty of Science and Arts, Department of Chemistry, Aydın, Turkey
| | - Murat Uygun
- Adnan Menderes University, Faculty of Science and Arts, Department of Chemistry, Aydın, Turkey; Adnan Menderes University, Nanotechnology Application and Research Center, Aydın, Turkey
| | - Deniz Aktaş Uygun
- Adnan Menderes University, Faculty of Science and Arts, Department of Chemistry, Aydın, Turkey; Adnan Menderes University, Nanotechnology Application and Research Center, Aydın, Turkey.
| |
Collapse
|
26
|
Zhang Y, Wang Y, Zhang Z, Sobhy A, Sato S, Uchida M, Hasebe Y. Natural Molybdenite- and Tyrosinase-Based Amperometric Catechol Biosensor Using Acridine Orange as a Glue, Anchor, and Stabilizer for the Adsorbed Tyrosinase. ACS OMEGA 2021; 6:13719-13727. [PMID: 34095664 PMCID: PMC8173569 DOI: 10.1021/acsomega.1c00973] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 05/06/2021] [Indexed: 06/01/2023]
Abstract
To develop a natural mineral-based electrochemical enzyme biosensor, natural molybdenite (MLN), tyrosinase (TYR), and acridine orange (AO) were coadsorbed onto a glassy carbon electrode (GCE). The developed TYR/AO/MLN-GCE-based amperometric TYR biosensor exhibited excellent performance for highly sensitive determination of catechol (linear range, 0.1-80 μM; sensitivity, 0.0315 μA/μM; LOD, 0.029 μM; response time, <4 s) with good reproducibility and good operational and storage stabilities. The electrochemical impedance spectroscopy (EIS) and quartz crystal microbalance with dissipation (QCM-D) revealed interesting roles of AO: (1) an efficient glue for enhancing the amount of the adsorbed TYR on the MLN-GCE, (2) an anchor for efficient orientation of the adsorbed TYR on the MLN-GCE, and (3) a stabilizer providing a suitable microenvironment for the adsorbed TYR on the MLN-GCE surface. This physical adsorption-based AO-coupled enzyme-modification strategy onto natural MLN would be a versatile strategy to develop cost-effective and environment-friendly natural mineral-based electrochemical biosensors and bioelectronic devices.
Collapse
Affiliation(s)
- Yan Zhang
- School
of Chemical Engineering, University of Science
and Technology Liaoning, 185 Qianshan Middle Road, High-tech Zone, Anshan, Liaoning 114051, China
| | - Yue Wang
- School
of Chemical Engineering, University of Science
and Technology Liaoning, 185 Qianshan Middle Road, High-tech Zone, Anshan, Liaoning 114051, China
| | - Zhiqiang Zhang
- School
of Chemical Engineering, University of Science
and Technology Liaoning, 185 Qianshan Middle Road, High-tech Zone, Anshan, Liaoning 114051, China
| | - Ahmed Sobhy
- School
of Resources and Environmental Engineering, Shandong University of Technology, Zibo, Shandong 255049, China
- Central
Metallurgical Research and Development Institute, Helwan, Cairo 11421, Egypt
| | - Susumu Sato
- Department
of Information Systems, Saitama Institute
of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| | - Masaya Uchida
- Advanced
Science Research Laboratory, Saitama Institute
of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| | - Yasushi Hasebe
- Department
of Life Science and Green Chemistry, Saitama
Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan
| |
Collapse
|
27
|
Pereira MS, Maximino MD, Martin CS, Aoki PHB, Oliveira ON, Alessio P. Lipid-matrix effects on tyrosinase immobilization in Langmuir and Langmuir-Blodgett films. AN ACAD BRAS CIENC 2021; 93:e20200019. [PMID: 33787687 DOI: 10.1590/0001-3765202120200019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 05/17/2020] [Indexed: 11/22/2022] Open
Abstract
The immobilization of the enzyme tyrosinase (Tyr) in lipid matrices can be explored to produce biosensors for detecting polyphenols, which is relevant for the food industry. Herein, we shall demonstrate the importance of the lipid composition to immobilize the enzyme tyrosinase in Langmuir-Blodgett (LB) films. Tyr could be incorporated into Langmuir monolayers of arachidic acid (AA), 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) and 1,2-dipalmitoyl-sn-glycero-3-phospho-(1'-rac-glycerol) (sodium salt) (DPPG), having as the main effect an expansion in the monolayers. Results from polarization-modulated infrared reflection-absorption spectroscopy (PM-IRRAS) pointed to electrostatic interactions between the charged residues of Try and the lipid headgroups, in addition to changes in the order of lipid chains. The interaction between Tyr and DPPC in Langmuir monolayers can be correlated with the superior performance of DPPC/Tyr LB films used as biosensors to detect catechol by cyclic voltammetry. The molecular-level interactions assessed via PM-IRRAS are therefore believed to drive an immobilization process for Tyr in the lipid LB matrix and may serve as a general criterion to identify matrices that preserve enzyme activity.
Collapse
Affiliation(s)
- Matheus S Pereira
- Universidade Estadual Paulista/UNESP, Faculdade de Ciências e Tecnologia, Departamento de Física, Rua Roberto Símonsen, 305, Centro Educacional, Caixa Postal 467, 19060-900 Presidente Prudente, SP, Brazil
| | - Mateus D Maximino
- Universidade Estadual Paulista/UNESP, Faculdade de Ciências e Tecnologia, Departamento de Física, Rua Roberto Símonsen, 305, Centro Educacional, Caixa Postal 467, 19060-900 Presidente Prudente, SP, Brazil
| | - Cibely S Martin
- Universidade Estadual Paulista/UNESP, Faculdade de Ciências e Tecnologia, Departamento de Física, Rua Roberto Símonsen, 305, Centro Educacional, Caixa Postal 467, 19060-900 Presidente Prudente, SP, Brazil
| | - Pedro H B Aoki
- Universidade Estadual Paulista/UNESP, Faculdade de Ciências e Letras, Departamento de Biotecnologia, Av. Dom Antônio, 2100, Parque Universitário, Caixa Postal 65, 19806-900 Assis, SP, Brazil
| | - Osvaldo N Oliveira
- Universidade de São Paulo/USP, Instituto de Física de São Carlos, Av. Trabalhador São Carlense, 400, Parque Arnold Schimidt, Caixa Postal 369, 13566-590 São Carlos, SP, Brazil
| | - Priscila Alessio
- Universidade Estadual Paulista/UNESP, Faculdade de Ciências e Tecnologia, Departamento de Física, Rua Roberto Símonsen, 305, Centro Educacional, Caixa Postal 467, 19060-900 Presidente Prudente, SP, Brazil
| |
Collapse
|
28
|
Bounegru AV, Apetrei C. Voltamperometric Sensors and Biosensors Based on Carbon Nanomaterials Used for Detecting Caffeic Acid-A Review. Int J Mol Sci 2020; 21:E9275. [PMID: 33291758 PMCID: PMC7730703 DOI: 10.3390/ijms21239275] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/01/2020] [Accepted: 12/02/2020] [Indexed: 12/11/2022] Open
Abstract
Caffeic acid is one of the most important hydroxycinnamic acids found in various foods and plant products. It has multiple beneficial effects in the human body such as antioxidant, antibacterial, anti-inflammatory, and antineoplastic. Since overdoses of caffeic acid may have negative effects, the quality and quantity of this acid in foods, pharmaceuticals, food supplements, etc., needs to be accurately determined. The present paper analyzes the most representative scientific papers published mostly in the last 10 years which describe the development and characterization of voltamperometric sensors or biosensors based on carbon nanomaterials and/or enzyme commonly used for detecting caffeic acid and a series of methods which may improve the performance characteristics of such sensors.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galaţi, 47 Domnească Street, 800008 Galaţi, Romania;
| |
Collapse
|
29
|
3D-printed reduced graphene oxide/polylactic acid electrodes: A new prototyped platform for sensing and biosensing applications. Biosens Bioelectron 2020; 170:112684. [DOI: 10.1016/j.bios.2020.112684] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 08/30/2020] [Accepted: 10/02/2020] [Indexed: 12/19/2022]
|
30
|
Bounegru AV, Apetrei C. Development of a Novel Electrochemical Biosensor Based on Carbon Nanofibers-Gold Nanoparticles-Tyrosinase for the Detection of Ferulic Acid in Cosmetics. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6724. [PMID: 33255463 PMCID: PMC7727797 DOI: 10.3390/s20236724] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 11/21/2020] [Accepted: 11/23/2020] [Indexed: 01/16/2023]
Abstract
The present paper deals with the electrochemical behavior of three types of sensors based on modified screen-printed electrodes (SPEs): a sensor based on carbon nanofibers (CNF/SPE), a sensor based on nanofibers of carbon modified with gold nanoparticles (CNF-GNP/SPE) and a biosensor based on nanofibers of carbon modified with gold nanoparticles and tyrosinase (CNF-GNP-Ty/SPE). To prepare the biosensor, the tyrosinase (Ty) was immobilized on the surface of the electrode already modified with carbon nanofibers and gold nanoparticles, by the drop-and-dry technique. The electrochemical properties of the three electrodes were studied by cyclic voltammetry in electroactive solutions, and the position and shape of the active redox peaks are according to the nature of the materials modifying the electrodes. In the case of ferulic acid, a series of characteristic peaks were observed, the processes being more intense for the biosensor, with the higher sensitivity and selectivity being due to the immobilization of tyrosinase, a specific enzyme for phenolic compounds. The calibration curve was subsequently created using CNF-GNP-Ty/SPE in ferulic acid solutions of various concentrations in the range 0.1-129.6 μM. This new biosensor allowed low values of the detection threshold and quantification limit, 2.89 × 10-9 mol·L-1 and 9.64 × 10-9 mol·L-1, respectively, which shows that the electroanalytical method is feasible for quantifying ferulic acid in real samples. The ferulic acid was quantitatively determined in three cosmetic products by means of the CNF-GNP-Ty/SPE biosensor. The results obtained were validated by means of the spectrometric method in the infrared range, the differences between the values of the ferulic acid concentrations obtained by the two methods being under 5%.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galaţi, 47 Domnească Street, 800008 Galaţi, Romania;
| |
Collapse
|
31
|
Xin Y, Wang N, Wang C, Gao W, Chen M, Liu N, Duan J, Hou B. Electrochemical detection of hydroquinone and catechol with covalent organic framework modified carbon paste electrode. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114530] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
32
|
Raymundo-Pereira PA, Silva TA, Caetano FR, Ribovski L, Zapp E, Brondani D, Bergamini MF, Marcolino LH, Banks CE, Oliveira ON, Janegitz BC, Fatibello-Filho O. Polyphenol oxidase-based electrochemical biosensors: A review. Anal Chim Acta 2020; 1139:198-221. [PMID: 33190704 DOI: 10.1016/j.aca.2020.07.055] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 07/14/2020] [Accepted: 07/20/2020] [Indexed: 02/06/2023]
Abstract
The detection of phenolic compounds is relevant not only for their possible benefits to human health but also for their role as chemical pollutants, including as endocrine disruptors. The required monitoring of such compounds on-site or in field analysis can be performed with electrochemical biosensors made with polyphenol oxidases (PPO). In this review, we describe biosensors containing the oxidases tyrosinase and laccase, in addition to crude extracts and tissues from plants as enzyme sources. From the survey in the literature, we found that significant advances to obtain sensitive, robust biosensors arise from the synergy reached with a diversity of nanomaterials employed in the matrix. These nanomaterials are mostly metallic nanoparticles and carbon nanostructures, which offer a suitable environment to preserve the activity of the enzymes and enhance electron transport. Besides presenting a summary of contributions to electrochemical biosensors containing PPOs in the last five years, we discuss the trends and challenges to take these biosensors to the market, especially for biomedical applications.
Collapse
Affiliation(s)
| | - Tiago A Silva
- Departamento de Metalurgia e Química, Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), 35180-008, Timóteo, MG, Brazil
| | - Fábio R Caetano
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Laís Ribovski
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil
| | - Eduardo Zapp
- Department of Exact Sciences and Education, Federal University of Santa Catarina, 89036-256, Brazil
| | - Daniela Brondani
- Department of Exact Sciences and Education, Federal University of Santa Catarina, 89036-256, Brazil
| | - Marcio F Bergamini
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Luiz H Marcolino
- Laboratório de Sensores Eletroquímicos (LabSensE), Departamento de Química, Universidade Federal Do Paraná (UFPR), 81.531-980, Curitiba, PR, Brazil
| | - Craig E Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester, M1 5GD, UK
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, São Carlos, SP, Brazil
| | - Bruno C Janegitz
- Department of Nature Sciences, Mathematics and Education, Federal University of São Carlos, 13600-970, Araras, SP, Brazil.
| | - Orlando Fatibello-Filho
- Department of Chemistry, Federal University of São Carlos, 13560-970, São Carlos, SP, Brazil.
| |
Collapse
|
33
|
Kaçar C, Erden PE. An amperometric biosensor based on poly(L-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase-modified glassy carbon electrode for the determination of L-ascorbic acid. Anal Bioanal Chem 2020; 412:5315-5327. [PMID: 32533225 DOI: 10.1007/s00216-020-02747-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 05/23/2020] [Accepted: 05/28/2020] [Indexed: 02/07/2023]
Abstract
An amperometric L-ascorbic acid biosensor utilizing ascorbate oxidase (AOx) immobilized onto poly(L-aspartic acid) (P(L-Asp)) film was fabricated on carbon nanofiber (CNF) and nanodiamond particle (ND)-modified glassy carbon electrode (GCE). Effects of AOx, ND, and CNF amounts were investigated by monitoring the response currents of the biosensor at different amounts of AOx, ND, and CNF. The electropolymerization step of L-aspartic acid on CNF-ND/GCE surface was also optimized. Scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques were used to enlighten the modification steps of the biosensor. The effects of pH and applied potential were studied in detail to achieve the best analytical performance. Under optimized experimental conditions, the AOx/P(L-Asp)/ND-CNF/GCE biosensor showed a linear response to L-ascorbic acid in the range of 2.0 × 10-7-1.8 × 10-3 M with a detection limit of 1.0 × 10-7 M and sensitivity of 105.0 μAmM-1 cm-2. The novel biosensing platform showed good reproducibility and selectivity. The strong interaction between AOx and the P(L-Asp)/ND-CNF matrix was revealed by the high repeatability (3.4%) and good operational stability. The AOx/P(L-Asp)/ND-CNF/GCE biosensor was successfully applied to the determination of L-ascorbic acid in vitamin C effervescent tablet and pharmaceutical powder containing ascorbic acid with good results, which makes it a promising approach for quantification of L-ascorbic acid. Graphical abstract.
Collapse
Affiliation(s)
- Ceren Kaçar
- Department of Chemistry, Faculty of Science, Ankara University, 06100, Ankara, Turkey
| | - Pınar Esra Erden
- Department of Chemistry, Polatlı Faculty of Science and Arts, Ankara Hacı Bayram Veli University, 06900, Ankara, Turkey.
| |
Collapse
|
34
|
Dabhade A, Jayaraman S, Paramasivan B. Colorimetric paper bioassay by horseradish peroxidase for the detection of catechol and resorcinol in aqueous samples. Prep Biochem Biotechnol 2020; 50:849-856. [DOI: 10.1080/10826068.2020.1760883] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Ajinkya Dabhade
- Department of Biotechnology and Medical Engineering, Agricultural and Environmental Biotechnology Lab, National Institute of Technology Rourkela, Rourkela, India
| | - Sivaraman Jayaraman
- Department of Biotechnology and Medical Engineering, Medical Electronics and Instrumentation Lab, National Institute of Technology Rourkela, Rourkela, India
| | - Balasubramanian Paramasivan
- Department of Biotechnology and Medical Engineering, Agricultural and Environmental Biotechnology Lab, National Institute of Technology Rourkela, Rourkela, India
| |
Collapse
|
35
|
Abstract
Over the past two decades, phenol oxidases, particularly laccases and tyrosinases, have been extensively used for the removal of numerous pollutants in wastewaters due to their broad substrate specificity and their ability to use readily accessible molecular oxygen as the essential cofactor. As for other enzymes, immobilisation of laccases and tyrosinases has been shown to improve the performance and efficiency of the biocatalysts in solution. Several reviews have addressed the enzyme immobilisation techniques and the application of phenol oxidases to decontaminate wastewaters. This paper offers an overview of the recent publications, mainly from 2012 onwards, on the various immobilisation techniques applied to laccases and tyrosinases to induce and/or increase the performance of the biocatalysts. In this paper, the emphasis is on the efficiencies achieved, in terms of structural modifications, stability and resistance to extreme conditions (pH, temperature, inhibitors, etc.), reactivity, reusability, and broad substrate specificity, particularly for application in bioremediation processes. The advantages and disadvantages of several enzyme immobilisation techniques are also discussed. The relevance and effectiveness of the immobilisation techniques with respect to wastewater decontamination are critically assessed. A perspective on the future directions for large-scale application of the phenol oxidases in immobilised forms is provided.
Collapse
|
36
|
Peregrino P, Cavallari MR, Fonseca FJ, Moreira SGC, Sales MJ, Paterno LG. Starch-Mediated Immobilization, Photochemical Reduction, and Gas Sensitivity of Graphene Oxide Films. ACS OMEGA 2020; 5:5001-5012. [PMID: 32201786 PMCID: PMC7081415 DOI: 10.1021/acsomega.9b03892] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 02/25/2020] [Indexed: 05/25/2023]
Abstract
This work unveils the roles played by potato starch (ST) in the immobilization, photochemical reduction, and gas sensitivity of graphene oxide (GO) films. The ST/GO films are assembled layer by layer (LbL) onto quartz substrates by establishing mutual hydrogen bonds that drive a stepwise film growth, with equal amounts of materials being adsorbed in each deposition cycle. Afterward, the films are photochemically reduced with UV irradiation (254 nm), following a first-order kinetics that proceeds much faster when GO is assembled along with ST instead of a nonoxygenated polyelectrolyte, namely, poly(diallyl dimethylammonium) hydrochloride (PDAC). Finally, the gas-sensing performance of ST/reduced graphene oxide (RGO) and PDAC/RGO sensors fabricated via LbL atop of gold interdigitated microelectrodes is evaluated at different relative humidity levels and in different concentrations of ammonia, ethanol, and acetone. In comparison to the PDAC/RGO sensor, the ones containing ST are much more sensitive, especially when operating in a high-relative-humidity environment. An array comprising these chemical sensors provides unique electrical fingerprints for each of the investigated analytes and is capable of discriminating and quantifying them in a wide range of concentrations, from 10 to 1000 ppm.
Collapse
Affiliation(s)
- Priscilla
P. Peregrino
- Laboratório
de Pesquisa em Polímeros e Nanomateriais, Instituto de Química, Universidade de Brasília, Brasília, DF 70904-970, Brazil
| | - Marco R. Cavallari
- Universidade
Federal da Integração Latino-Americana, Engenharia de
Energia, Foz do
Iguaçú, PR 85866-000, Brazil
- Departamento
de Engenharia de Sistemas Eletrônicos, Escola Politécnica da Universidade de São Paulo, São Paulo, SP 05424-970, Brazil
| | - Fernando J. Fonseca
- Departamento
de Engenharia de Sistemas Eletrônicos, Escola Politécnica da Universidade de São Paulo, São Paulo, SP 05424-970, Brazil
| | - Sanclayton G. C. Moreira
- Instituto
de Ciências Exatas e Naturais (ICEN), Universidade Federal do Pará, Belém, PA 66075-900, Brazil
| | - Maria José
A. Sales
- Laboratório
de Pesquisa em Polímeros e Nanomateriais, Instituto de Química, Universidade de Brasília, Brasília, DF 70904-970, Brazil
| | - Leonardo G. Paterno
- Laboratório
de Pesquisa em Polímeros e Nanomateriais, Instituto de Química, Universidade de Brasília, Brasília, DF 70904-970, Brazil
| |
Collapse
|
37
|
Kurbanoglu S, Erkmen C, Uslu B. Frontiers in electrochemical enzyme based biosensors for food and drug analysis. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115809] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
38
|
Shakerian F, Zhao J, Li SP. Recent development in the application of immobilized oxidative enzymes for bioremediation of hazardous micropollutants - A review. CHEMOSPHERE 2020; 239:124716. [PMID: 31521938 DOI: 10.1016/j.chemosphere.2019.124716] [Citation(s) in RCA: 77] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 08/11/2019] [Accepted: 08/29/2019] [Indexed: 05/05/2023]
Abstract
During the past several years, abundant progresses has been made in the development of immobilized oxidative enzymes with focus on finding new support materials, improving the immobilization methods and their applications. Nowadays, immobilized oxidative enzymes are broadly accepted as a green way to face the challenge of high amounts of micropollutants in nature. Among all oxidative enzymes, laccases and horseradish peroxidase were used frequently in recent years as they are general oxidative enzymes with ability to oxidize various types of compounds. Immobilized laccase or horseradish peroxidase are showed better stability, and reusability as well as easy separation from reaction mixture that make them more favorable and economic in compared to free enzymes. However, additional improvements are still essential such as: development of the new materials for immobilization with higher capacity, easy preparation, and cheaper price. Moreover, immobilization methods are still need improving to become more efficient and avoid enzyme wasting during immobilization and enzyme leakage through working cycles.
Collapse
Affiliation(s)
- Farid Shakerian
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, China
| | - Jing Zhao
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, China.
| | - Shao-Ping Li
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macau, China.
| |
Collapse
|
39
|
Pirzada M, Altintas Z. Nanomaterials for Healthcare Biosensing Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E5311. [PMID: 31810313 PMCID: PMC6928990 DOI: 10.3390/s19235311] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 11/22/2019] [Accepted: 11/27/2019] [Indexed: 12/12/2022]
Abstract
In recent years, an increasing number of nanomaterials have been explored for their applications in biomedical diagnostics, making their applications in healthcare biosensing a rapidly evolving field. Nanomaterials introduce versatility to the sensing platforms and may even allow mobility between different detection mechanisms. The prospect of a combination of different nanomaterials allows an exploitation of their synergistic additive and novel properties for sensor development. This paper covers more than 290 research works since 2015, elaborating the diverse roles played by various nanomaterials in the biosensing field. Hence, we provide a comprehensive review of the healthcare sensing applications of nanomaterials, covering carbon allotrope-based, inorganic, and organic nanomaterials. These sensing systems are able to detect a wide variety of clinically relevant molecules, like nucleic acids, viruses, bacteria, cancer antigens, pharmaceuticals and narcotic drugs, toxins, contaminants, as well as entire cells in various sensing media, ranging from buffers to more complex environments such as urine, blood or sputum. Thus, the latest advancements reviewed in this paper hold tremendous potential for the application of nanomaterials in the early screening of diseases and point-of-care testing.
Collapse
Affiliation(s)
| | - Zeynep Altintas
- Technical University of Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany;
| |
Collapse
|
40
|
de Cezaro AM, Rigo AA, Martinazzo J, Muenchen DK, Manzoli A, Correa DS, Steffens J, Steffens C. Cantilever Nanobiosensor Functionalized with Tyrosinase for Detection of Estrone and β-estradiol in Water. Appl Biochem Biotechnol 2019; 190:1512-1524. [PMID: 31784877 DOI: 10.1007/s12010-019-03195-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Accepted: 11/11/2019] [Indexed: 12/16/2022]
Abstract
This work aimed to develop cantilever nanobiosensor functionalized with tyrosinase enzyme to detect 17β-estradiol and estrone hormones. In this system, the tyrosinase enzyme was covalently immobilized by self-assembled monolayer onto the cantilever sensor surface. It was possible to verify that the high hormone concentration investigated resulted in high voltage response. The nanobiosensor presented a distinction between the concentrations evaluated and was verified sensitivities of 0.497 and 0.101 V/μg, limit of detection of 0.1 and 0.4 ng/L for the hormones 17β-estradiol and estrone, respectively. The device showed good reversibility and during 30 days of storage maintained about 99% of the original signal. The cantilever nanobiosensor applied in different water samples (ultrapure, river, tap, and mineral) showed good performance, so could be readily extended toward the on-site monitoring of the other trace small molecular pollutants in environmental water matrices.
Collapse
Affiliation(s)
- Alana Marie de Cezaro
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Aline Andressa Rigo
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Janine Martinazzo
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Daniela Kunkel Muenchen
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Alexandra Manzoli
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Daniel Souza Correa
- Nanotechnology National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, P.O. Box 741, São Carlos, SP, 13560-970, Brazil
| | - Juliana Steffens
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil
| | - Clarice Steffens
- Department of Food Engineering, URI Erechim, Av. Sete de Setembro, 1621, Erechim, RS, 99709-910, Brazil.
| |
Collapse
|
41
|
Min K, Park GW, Yoo YJ, Lee JS. A perspective on the biotechnological applications of the versatile tyrosinase. BIORESOURCE TECHNOLOGY 2019; 289:121730. [PMID: 31279520 DOI: 10.1016/j.biortech.2019.121730] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 06/26/2019] [Accepted: 06/28/2019] [Indexed: 06/09/2023]
Abstract
Tyrosinase (E.C. 1.14.18. 1) is a type of Cu-containing oxidoreductase which has bifunctional activity for various phenolic substrates: ortho-hydroxylation of monophenols to diphenols (a cresolase activity) and oxidation of diphenols to quinones (a catecholase activity). Based on the broad substrate spectrum, tyrosinase has been used in bioremediation of phenolic pollutants, constructing biosensors for identifying phenolic compounds, and L-DOPA synthesis. Furthermore, not only tyrosinase has been used to produce useful polyphenol derivatives, but also it is recently revealed that the promiscuous activity of tyrosinase is closely related with delignification in the biorefinery. Accordingly, tyrosinase might be a potential biocatalyst for industrial applications (e.g., electroenzymatic L-DOPA production, but its long-term stability and reusability should be further explored. In this review, we emphasize the versatility of tyrosinase, which includes conventional applications, and suggest new perspectives as an industrial biocatalyst (e.g., electroenzymatic L-DOPA production). Especially, this review focuses on and comprehensively discusses recent innovative studies.
Collapse
Affiliation(s)
- Kyoungseon Min
- Bio/Energy R&D Center, Korea Institute of Energy Research (KIER), Gwangju 61003, Republic of Korea
| | - Gwon Woo Park
- Bio/Energy R&D Center, Korea Institute of Energy Research (KIER), Gwangju 61003, Republic of Korea
| | - Young Je Yoo
- School of Chemical and Biological Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Jin-Suk Lee
- Bio/Energy R&D Center, Korea Institute of Energy Research (KIER), Gwangju 61003, Republic of Korea.
| |
Collapse
|
42
|
Tyrosinase-immobilized CNT based biosensor for highly-sensitive detection of phenolic compounds. Biosens Bioelectron 2019; 132:279-285. [PMID: 30884314 DOI: 10.1016/j.bios.2019.03.008] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 03/05/2019] [Accepted: 03/06/2019] [Indexed: 11/20/2022]
Abstract
Highly sensitive phenol biosensor was developed by using well-dispersed carbon nanotubes (CNTs) in enzyme solution and adding CNTs in enzyme electrodes. First, the intact CNTs were dispersed in aqueous tyrosinase (TYR) solution, and TYR molecules were precipitated and crosslinked to prepare the sample of enzyme adsorption, precipitation and crosslinking (EAPC). EAPC exhibited 10.5- and 5.4-fold higher TYR activity per mg of CNTs as compared to enzyme adsorption (EA) and enzyme adsorption/crosslinking (EAC), respectively. EAPC retained 29% of its initial activity after incubation at 40 °C for 128 h, while EA and EAC showed no residual activities, respectively. In biosensing a model phenolic compound of catechol, the sensitivities of EA, EAC and EAPC electrodes on glassy carbon electrode (GCE) were 34, 281 and 675 µA/mM/cm2, respectively. When 90 w/w% CNTs were added to the enzyme electrodes, the sensitivities of EA, EAC, and EAPC electrodes were 146, 427, and 1160 µA/mM/cm2, respectively, and the EAPC electrode showed a 2.3-fold increase in sensitivity upon CNT addition. Catechol and phenol could also be detected by EAPC on the screen-printed electrode (SPE), with sensitivities of 1340 and 1170 µA/mM/cm2, respectively. The sensitivity of EAPC-SPE for phenol detection in the effluent from real municipal wastewater treatment plant was 1100 µA/mM/cm2. The sensitivity of EAPC-SPE retained 74% of its initial sensitivity after incubation at 40 °C for 12 h. The combination of EAPC immobilization and CNT addition has great potential for application in the development of sensitive enzyme biosensors for various analytes and phenols in water environments.
Collapse
|
43
|
dos Santos Pereira T, Mauruto de Oliveira GC, Santos FA, Raymundo-Pereira PA, Oliveira ON, Janegitz BC. Use of zein microspheres to anchor carbon black and hemoglobin in electrochemical biosensors to detect hydrogen peroxide in cosmetic products, food and biological fluids. Talanta 2019; 194:737-744. [DOI: 10.1016/j.talanta.2018.10.068] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 10/17/2018] [Accepted: 10/19/2018] [Indexed: 12/22/2022]
|
44
|
Assessment of the Polyphenol Indices and Antioxidant Capacity for Beers and Wines Using a Tyrosinase-Based Biosensor Prepared by Sinusoidal Current Method. SENSORS 2018; 19:s19010066. [PMID: 30585182 PMCID: PMC6339202 DOI: 10.3390/s19010066] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Revised: 12/14/2018] [Accepted: 12/19/2018] [Indexed: 12/27/2022]
Abstract
The application of a novel Poly(3,4-ethylenedioxythiophene)-Tyrosinase/Sonogel-Carbon electrode (PEDOT-Tyr/SNGC) biosensor to beers and wines analysis is proposed. This biosensor implies a new Sinusoidal Current (SC) electrodeposition method to immobilize the enzyme generating a nanostructure surface. The biosensors were characterized electrochemically, employing cyclic voltammetry and electrochemical impedance spectroscopy. Sensitivity, limit of detection, and correlation coefficients of the linear fitting were 2.40 × 10-4 µA·µM-1, 4.33 µM, and R² = 0.9987, respectively. Caffeic acid is used as the reference polyphenol. A sampling of nine beers (four lager, three stout, and two non-alcoholic beers), and four wines (three red and one white wine) purchased in a local store was performed. The Polyphenol indeces for beers and wines have been assessed using the proposed biosensor, and the obtained values are in agreement with the literature data. Antioxidant properties of the samples using the 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid (ABTS) radical spectrophotometric method were also evaluated. The correlation between the polyphenol index and the antioxidant capacity was obtained for beers and wines.
Collapse
|
45
|
Orzari LO, Santos FA, Janegitz BC. Manioc starch thin film as support of reduced graphene oxide: A novel architecture for electrochemical sensors. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.06.036] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|