1
|
Khan R, Anwar F, Ghazali FM. A comprehensive review of mycotoxins: Toxicology, detection, and effective mitigation approaches. Heliyon 2024; 10:e28361. [PMID: 38628751 PMCID: PMC11019184 DOI: 10.1016/j.heliyon.2024.e28361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 01/19/2024] [Accepted: 01/21/2024] [Indexed: 04/19/2024] Open
Abstract
Mycotoxins, harmful compounds produced by fungal pathogens, pose a severe threat to food safety and consumer health. Some commonly produced mycotoxins such as aflatoxins, ochratoxin A, fumonisins, trichothecenes, zearalenone, and patulin have serious health implications in humans and animals. Mycotoxin contamination is particularly concerning in regions heavily reliant on staple foods like grains, cereals, and nuts. Preventing mycotoxin contamination is crucial for a sustainable food supply. Chromatographic methods like thin layer chromatography (TLC), gas chromatography (GC), high-performance liquid chromatography (HPLC), and liquid chromatography coupled with a mass spectrometer (LC/MS), are commonly used to detect mycotoxins; however, there is a need for on-site, rapid, and cost-effective detection methods. Currently, enzyme-linked immunosorbent assays (ELISA), lateral flow assays (LFAs), and biosensors are becoming popular analytical tools for rapid detection. Meanwhile, preventing mycotoxin contamination is crucial for food safety and a sustainable food supply. Physical, chemical, and biological approaches have been used to inhibit fungal growth and mycotoxin production. However, new strains resistant to conventional methods have led to the exploration of novel strategies like cold atmospheric plasma (CAP) technology, polyphenols and flavonoids, magnetic materials and nanoparticles, and natural essential oils (NEOs). This paper reviews recent scientific research on mycotoxin toxicity, explores advancements in detecting mycotoxins in various foods, and evaluates the effectiveness of innovative mitigation strategies for controlling and detoxifying mycotoxins.
Collapse
Affiliation(s)
- Rahim Khan
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
| | - Farooq Anwar
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
- Institute of Chemistry, University of Sargodha, Sargodha, 40100, Pakistan
| | - Farinazleen Mohamad Ghazali
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
| |
Collapse
|
2
|
Dkhar DS, Kumari R, Mahapatra S, Divya, Kumar R, Tripathi T, Chandra P. Antibody-receptor bioengineering and its implications in designing bioelectronic devices. Int J Biol Macromol 2022; 218:225-242. [PMID: 35870626 DOI: 10.1016/j.ijbiomac.2022.07.109] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 07/14/2022] [Accepted: 07/15/2022] [Indexed: 11/16/2022]
Abstract
Antibodies play a crucial role in the defense mechanism countering pathogens or foreign antigens in eukaryotes. Its potential as an analytical and diagnostic tool has been exploited for over a century. It forms immunocomplexes with a specific antigen, which is the basis of immunoassays and aids in developing potent biosensors. Antibody-based sensors allow for the quick and accurate detection of various analytes. Though classical antibodies have prolonged been used as bioreceptors in biosensors fabrication due to their increased fragility, they have been engineered into more stable fragments with increased exposure of their antigen-binding sites in the recent era. In biosensing, the formats constructed by antibody engineering can enhance the signal since the resistance offered by a conventional antibody is much more than these fragments. Hence, signal amplification can be observed when antibody fragments are utilized as bioreceptors instead of full-length antibodies. We present the first systematic review on engineered antibodies as bioreceptors with the description of their engineering methods. The detection of various target analytes, including small molecules, macromolecules, and cells using antibody-based biosensors, has been discussed. A comparison of the classical polyclonal, monoclonal, and engineered antibodies as bioreceptors to construct highly accurate, sensitive, and specific sensors is also discussed.
Collapse
Affiliation(s)
- Daphika S Dkhar
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India
| | - Rohini Kumari
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India
| | - Supratim Mahapatra
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India
| | - Divya
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India
| | - Rahul Kumar
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India
| | - Timir Tripathi
- Molecular and Structural Biophysics Laboratory, Department of Biochemistry, North-Eastern Hill University, Shillong 793022, India; Regional Director's Office, Indira Gandhi National Open University (IGNOU), Regional Centre Kohima, Kenuozou, Kohima 797001, India.
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nano-bioengineering, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Uttar Pradesh 221005, India.
| |
Collapse
|
3
|
Rapid Detection of Deoxynivalenol in Dry Pasta Using a Label-Free Immunosensor. BIOSENSORS 2022; 12:bios12040240. [PMID: 35448300 PMCID: PMC9027790 DOI: 10.3390/bios12040240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 12/13/2022]
Abstract
This work focused on the development and optimization of an impedimetric label-free immunosensor for detecting deoxynivalenol (DON). A monoclonal antibody for DON detection was immobilized on a modified gold electrode with a cysteamine layer and polyamidoamine (PAMAM) dendrimers. Cyclic voltammetry and electrochemical impedance spectroscopy techniques were used to monitor the layer-by-layer development of the immunosensor design, while electrochemical impedance spectroscopy and differential pulse voltammetry were employed to investigate the antigen/antibody interaction. The PAMAM dendrimers, allowing to immobilize a large number of monoclonal antibodies, permitted reaching, through the DPV technique, a high sensitivity and a low limit of detection equal to 1 ppb. The evaluation of the possible reuse of the immunosensors highlighted a decrease in the analytical performances of the regenerated immunosensors. After evaluating the matrix effect, the developed immunosensor was used to quantify DON in pasta samples spiked with a known mycotoxin concentration. Taking into consideration the DON extraction procedure used for the pasta samples and the matrix effect related to the sample, the proposed immunosensor showed a limit of detection of 50 ppb, which is lower than the maximum residual limit imposed by European Regulation for DON in dry pasta (750 ppb).
Collapse
|
4
|
Wang Y, Zhang C, Wang J, Knopp D. Recent Progress in Rapid Determination of Mycotoxins Based on Emerging Biorecognition Molecules: A Review. Toxins (Basel) 2022; 14:toxins14020073. [PMID: 35202100 PMCID: PMC8874725 DOI: 10.3390/toxins14020073] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/14/2022] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
Mycotoxins are secondary metabolites produced by fungal species, which pose significant risk to humans and livestock. The mycotoxins which are produced from Aspergillus, Penicillium, and Fusarium are considered most important and therefore regulated in food- and feedstuffs. Analyses are predominantly performed by official laboratory methods in centralized labs by expert technicians. There is an urgent demand for new low-cost, easy-to-use, and portable analytical devices for rapid on-site determination. Most significant advances were realized in the field bioanalytical techniques based on molecular recognition. This review aims to discuss recent progress in the generation of native biomolecules and new bioinspired materials towards mycotoxins for the development of reliable bioreceptor-based analytical methods. After brief presentation of basic knowledge regarding characteristics of most important mycotoxins, the generation, benefits, and limitations of present and emerging biorecognition molecules, such as polyclonal (pAb), monoclonal (mAb), recombinant antibodies (rAb), aptamers, short peptides, and molecularly imprinted polymers (MIPs), are discussed. Hereinafter, the use of binders in different areas of application, including sample preparation, microplate- and tube-based assays, lateral flow devices, and biosensors, is highlighted. Special focus, on a global scale, is placed on commercial availability of single receptor molecules, test-kits, and biosensor platforms using multiplexed bead-based suspension assays and planar biochip arrays. Future outlook is given with special emphasis on new challenges, such as increasing use of rAb based on synthetic and naïve antibody libraries to renounce animal immunization, multiple-analyte test-kits and high-throughput multiplexing, and determination of masked mycotoxins, including stereoisomeric degradation products.
Collapse
Affiliation(s)
- Yanru Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Cui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
- Correspondence: (J.W.); (D.K.)
| | - Dietmar Knopp
- Chair for Analytical Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische Universitat München, Elisabeth-Winterhalter-Weg 6, D-81377 München, Germany
- Correspondence: (J.W.); (D.K.)
| |
Collapse
|
5
|
Recent Achievements in Electrochemical and Surface Plasmon Resonance Aptasensors for Mycotoxins Detection. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9070180] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Mycotoxins are secondary metabolites of fungi that contaminate agriculture products. Their release in the environment can cause severe damage to human health. Aptasensors are compact analytical devices that are intended for the fast and reliable detection of various species able to specifically interact with aptamers attached to the transducer surface. In this review, assembly of electrochemical and surface plasmon resonance (SPR) aptasensors are considered with emphasis on the mechanism of signal generation. Moreover, the properties of mycotoxins and the aptamers selected for their recognition are briefly considered. The analytical performance of biosensors developed within last three years makes it possible to determine mycotoxin residues in water and agriculture/food products on the levels below their maximal admissible concentrations. Requirements for the development of sample treatment and future trends in aptasensors are also discussed.
Collapse
|
6
|
Sohrabi H, Arbabzadeh O, Khaaki P, Khataee A, Majidi MR, Orooji Y. Patulin and Trichothecene: characteristics, occurrence, toxic effects and detection capabilities via clinical, analytical and nanostructured electrochemical sensing/biosensing assays in foodstuffs. Crit Rev Food Sci Nutr 2021; 62:5540-5568. [PMID: 33624529 DOI: 10.1080/10408398.2021.1887077] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Patulin and Trichothecene as the main groups of mycotoxins in significant quantities can cause health risks from allergic reactions to death on both humans and animals. Accordingly, rapid and highly sensitive determination of these toxics agents is of great importance. This review starts with a comprehensive outlook regarding the characteristics, occurrence and toxic effects of Patulin and Trichothecene. In the following, numerous clinical and analytical approaches have been extensively discussed. The main emphasis of this review is placed on the utilization of novel nanomaterial based electrochemical sensing/biosensing tools for highly sensitive determination of Patulin and Trichothecene. Furthermore, a detailed and comprehensive comparison has been performed between clinical, analytical and sensing methods. Subsequently, the nanomaterial based electrochemical sensing platforms have been approved as reliable tools for on-site analysis of Patulin and Trichothecene in food processing and manufacturing industries. Different nanomaterials in improving the performance of detecting assays were investigated and have various benefits toward clinical and analytical methods. This paper would address the limitations in the current developments as well as the future challenges involved in the successful construction of sensing approaches with the functionalized nanomaterials and also allow exploring into core-research works regarding this area.
Collapse
Affiliation(s)
- Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Omid Arbabzadeh
- Faculty of Chemical and Petroleum Engineering, University of Tabriz, Tabriz, Iran
| | - Pegah Khaaki
- Department of Biology, Faculty of Natural Science, University of Tabriz, Tabriz, Iran
| | - Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.,Рeoples' Friendship University of Russia (RUDN University), Moscow, Russian Federation
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Yasin Orooji
- College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, China
| |
Collapse
|
7
|
Leivo J, Vehniäinen M, Lamminmäki U. Phage Display Selection of an Anti-Idiotype-Antibody with Broad-Specificity to Deoxynivalenol Mycotoxins. Toxins (Basel) 2020; 13:toxins13010018. [PMID: 33379255 PMCID: PMC7823383 DOI: 10.3390/toxins13010018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 12/17/2020] [Accepted: 12/21/2020] [Indexed: 11/16/2022] Open
Abstract
The use of synthetic antibody libraries and phage displays provides an efficient and robust method for the generation of antibodies against a wide range of targets with highly specific binding properties. As the in vitro selection conditions can be easily controlled, these methods enable the rapid generation of binders against difficult targets such as toxins and haptens. In this study, we used deoxynivalenol mycotoxin as a target to generate anti-idiotype-antibodies with unique binding properties from synthetic antibody libraries. The binding of the selected anti-idiotype antibodies can be efficiently inhibited with the addition of free isoforms of deoxynivalenol. The antibody was consecutively used to develop deoxynivalenol-specific ELISA and TRF-immunoassays, which can detect deoxynivalenol and two of the most common metabolic isoforms in the range of 78-115 ng/mL.
Collapse
Affiliation(s)
- Janne Leivo
- Department of Biochemistry, University of Turku, 20520 Turku, Finland;
- Correspondence: ; Tel.: +358-44-0555738
| | | | - Urpo Lamminmäki
- Department of Biochemistry, University of Turku, 20520 Turku, Finland;
| |
Collapse
|
8
|
Subak H, Selvolini G, Macchiagodena M, Ozkan-Ariksoysal D, Pagliai M, Procacci P, Marrazza G. Mycotoxins aptasensing: From molecular docking to electrochemical detection of deoxynivalenol. Bioelectrochemistry 2020; 138:107691. [PMID: 33232846 DOI: 10.1016/j.bioelechem.2020.107691] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 10/15/2020] [Accepted: 10/20/2020] [Indexed: 12/16/2022]
Abstract
This work proposes a voltammetric aptasensor to detect deoxynivalenol (DON) mycotoxin. The development steps of the aptasensor were partnered for the first time to a computational study to gain insights onto the molecular mechanisms involved into the interaction between a thiol-tethered DNA aptamer (80mer-SH) and DON. The exploited docking study allowed to find the binding region of the oligonucleotide sequence and to determine DON preferred orientation. A biotinylated oligonucleotide sequence (20mer-BIO) complementary to the aptamer was chosen to carry out a competitive format. Graphite screen-printed electrodes (GSPEs) were electrochemically modified with polyaniline and gold nanoparticles (AuNPs@PANI) by means of cyclic voltammetry (CV) and worked as a scaffold for the immobilization of the DNA aptamer. Solutions containing increasing concentrations of DON and a fixed amount of 20mer-BIO were dropped onto the aptasensor surface: the resulting hybrids were labeled with an alkaline phosphatase (ALP) conjugate to hydrolyze 1-naphthyl phosphate (1-NPP) substrate into 1-naphthol product, detected by differential pulse voltammetry (DPV). According to its competitive format, the aptasensor response was signal-off in the range 5.0-30.0 ng·mL-1 DON. A detection limit of 3.2 ng·mL-1 was achieved within a 1-hour detection time. Preliminary experiments on maize flour samples spiked with DON yielded good recovery values.
Collapse
Affiliation(s)
- Hasret Subak
- Yuzuncu Yil University, Department of Analytical Chemistry, Faculty of Pharmacy, 65010 Van, Turkey; Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy.
| | - Giulia Selvolini
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy.
| | - Marina Macchiagodena
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy.
| | - Dilsat Ozkan-Ariksoysal
- Ege University, Department of Analytical Chemistry, Faculty of Pharmacy, 35100 Bornova, Izmir, Turkey.
| | - Marco Pagliai
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy.
| | - Piero Procacci
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy.
| | - Giovanna Marrazza
- Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019, Sesto Fiorentino, Florence, Italy; Istituto Nazionale Biostrutture e Biosistemi, Viale delle Medaglie D'Oro 305, 00136 Rome, Italy.
| |
Collapse
|
9
|
Nelis JLD, Migliorelli D, Jafari S, Generelli S, Lou-Franco J, Salvador JP, Marco MP, Cao C, Elliott CT, Campbell K. The benefits of carbon black, gold and magnetic nanomaterials for point-of-harvest electrochemical quantification of domoic acid. Mikrochim Acta 2020; 187:164. [PMID: 32052200 PMCID: PMC7015955 DOI: 10.1007/s00604-020-4150-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Accepted: 01/28/2020] [Indexed: 12/02/2022]
Abstract
Gold nanostars (GNST), gold nanospheres (GNP) and carbon black (CB) are chosen as alternative nanomaterials to modify carbon screen-printed electrodes (c-SPEs). The resulting three kinds of modified c-SPEs (GNP-SPE, CB-SPE and GNSP-SPE) were electrochemically and microscopically characterized and compared with standardized c-SPEs after pretreatment with phosphate buffer by pre-anodization (pre-SPE). The results show outstanding electrochemical performance of the carbon black-modified SPEs which show low transient current, low capacitance and good porosity. A competitive chronoamperometric immunoassay for the shellfish toxin domoic acid (DA) is described. The performances of the CB-SPE, GNP-SPE and pre-SPE were compared. Hapten-functionalized magnetic beads were used to avoid individual c-SPE functionalization with antibody while enhancing the signal by creating optimum surface proximity for electron transfer reactions. This comparison shows that the CB-SPE biosensor operated best at a potential near - 50 mV (vs. Ag/AgCl) and enables DA to be determined with a detection limit that is tenfold lower compared to pre-SPE (4 vs. 0.4 ng mL-1). These results show very good agreement with HPLC data when analysing contaminated scallops, and the LOD is 0.7 mg DA kg-1 of shellfish. Graphical abstractSchematic representation of the magnetic bead-based immunoassay for the quantification of domoic acid (DA) in shellfish with nanomaterial-modified screen-printed electrodes. CB, carbon black; GNP, gold nanospheres; GNST, gold nanostars; MB, magnetic beads; DA-mAb, anti-DA monoclonal mouse antibody; HRP-pAb, horseradish conjugated polyclonal goat anti-mouse antibody; DA-BSA, bovine serum albumin conjugated DA; HQ, hydroquinone; BQ, benzoquinone.
Collapse
Affiliation(s)
- Joost L D Nelis
- Institute for Global Food Security, School of Biological Sciences, Queen's University, 19 Chlorine Gardens, Belfast, BT9 5DL, UK.
| | | | - Safiye Jafari
- CSEM SA, Bahnhofstrasse 1, 7302, Landquart, Switzerland
| | | | - Javier Lou-Franco
- Institute for Global Food Security, School of Biological Sciences, Queen's University, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - J Pablo Salvador
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034, Barcelona, Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034, Barcelona, Spain
| | - M Pilar Marco
- Nanobiotechnology for Diagnostics (Nb4D), Institute for Advanced Chemistry of Catalonia (IQAC) of the Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034, Barcelona, Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034, Barcelona, Spain
| | - Cuong Cao
- Institute for Global Food Security, School of Biological Sciences, Queen's University, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Christopher T Elliott
- Institute for Global Food Security, School of Biological Sciences, Queen's University, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen's University, 19 Chlorine Gardens, Belfast, BT9 5DL, UK
| |
Collapse
|
10
|
Ramadan MM, Mohamed MA, Almoammar H, Abd-Elsalam KA. Magnetic nanomaterials for purification, detection, and control of mycotoxins. NANOMYCOTOXICOLOGY 2020:87-114. [DOI: 10.1016/b978-0-12-817998-7.00005-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
11
|
Abstract
Immunosensors are compact tools on which antibody and antigen interactions are formed. The specific interaction between antibody and antigen is detected by using a transducer and an electrical signal is measured. This specific interaction between these molecules makes immunosensor very attractive for several applications in different fields. Electrochemical immunosensors are successful devices in selective and sensitive detection of several analytes. Electrochemical transducing methods such as voltammetric, potentiometric, conductometric or impedimetric have been utilized in different applications due to their excellent properties such as being low-cost, sensitivity and simplicity. In this chapter, the fundamentals of electrochemical immunosensors are summarized and different applications in food, environmental and clinical analyses are investigated and discussed.
Collapse
Affiliation(s)
- Elif Burcu Aydin
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey.
| | - Muhammet Aydin
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| |
Collapse
|
12
|
Abstract
Modern analysis of food and feed is mostly focused on development of fast and reliable portable devices intended for field applications. In this review, electrochemical biosensors based on immunological reactions and aptamers are considered in the determination of mycotoxins as one of most common contaminants able to negatively affect human health. The characteristics of biosensors are considered from the point of view of general principles of bioreceptor implementation and signal transduction providing sub-nanomolar detection limits of mycotoxins. Moreover, the modern trends of bioreceptor selection and modification are discussed as well as future trends of biosensor development for mycotoxin determination are considered.
Collapse
|
13
|
Valera E, García-Febrero R, Elliott CT, Sánchez-Baeza F, Marco MP. Electrochemical nanoprobe-based immunosensor for deoxynivalenol mycotoxin residues analysis in wheat samples. Anal Bioanal Chem 2019; 411:1915-1926. [DOI: 10.1007/s00216-018-1538-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 11/16/2018] [Accepted: 12/04/2018] [Indexed: 01/07/2023]
|
14
|
Antibody immobilization strategy for the development of a capacitive immunosensor detecting zearalenone. Talanta 2018; 191:202-208. [PMID: 30262050 DOI: 10.1016/j.talanta.2018.08.062] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 08/21/2018] [Accepted: 08/24/2018] [Indexed: 11/20/2022]
Abstract
A highly sensitive flow-injection capacitive immunosensor was developed for detection of the mycotoxin zearalenone (ZEN). Different strategies for immobilization of an anti-ZEN antibody on the surface of a gold electrode, i.e. polytyramine or self-assembled monolayers (SAMs) of 3-mercaptopropionic acid (3-MPA) and lipoic acid (LA), were used and their performances were compared. The LA- and 3-MPA-based systems showed broad linear ranges for ZEN determination, i.e. from 0.010 nM to 10 nM and from 0.020 nM to 10 nM, respectively. Under optimal conditions, the LA-based immunosensor was capable of performing up till 13 regeneration-interaction cycles (with use of glycine HCl, pH 2.4) with a limit of detection (LOD) of 0.0060 nM, equivalent to 1.9 pg mL-1. It also demonstrated a good inter-assay precision (RSD < 10%). However, the tyramine-based capacitive immunosensor showed a bad repeatability (only 4 regeneration-interaction cycles were possible) and inter-assay precision (RSD > 15%) which did not allow sensitive and precise measurements. The LA-based method was compared with a direct ELISA. These results demonstrated that the label-free developed capacitive immunosensor had a better sensitivity and shorter analysis time in comparison with the direct microwell-plate format.
Collapse
|
15
|
Evtugyn G, Subjakova V, Melikishvili S, Hianik T. Affinity Biosensors for Detection of Mycotoxins in Food. ADVANCES IN FOOD AND NUTRITION RESEARCH 2018; 85:263-310. [PMID: 29860976 DOI: 10.1016/bs.afnr.2018.03.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
This chapter reviews recent achievements in methods of detection of mycotoxins in food. Special focus is on the biosensor technology that utilizes antibodies and nucleic acid aptamers as receptors. Development of biosensors is based on the immobilization of antibodies or aptamers onto various conventional supports like gold layer, but also on nanomaterials such as graphene oxide, carbon nanotubes, and quantum dots that provide an effective platform for achieving high sensitivity of detection using various physical methods, including electrochemical, mass sensitive, and optical. The biosensors developed so far demonstrate high sensitivity typically in subnanomolar limit of detection. Several biosensors have been validated in real samples. The sensitivity of biosensors is similar and, in some cases, even better than traditional analytical methods such as ELISA or chromatography. We believe that future trends will be focused on improving biosensor properties toward practical application in food industry.
Collapse
Affiliation(s)
- Gennady Evtugyn
- Analytical Chemistry Department, Chemistry Institute of Kazan Federal University, Kazan, Russian Federation
| | - Veronika Subjakova
- Department of Nuclear Physics and Biophysics, Comenius University, Bratislava, Slovakia
| | - Sopio Melikishvili
- Department of Nuclear Physics and Biophysics, Comenius University, Bratislava, Slovakia
| | - Tibor Hianik
- Department of Nuclear Physics and Biophysics, Comenius University, Bratislava, Slovakia.
| |
Collapse
|
16
|
Peltomaa R, Benito-Peña E, Moreno-Bondi MC. Bioinspired recognition elements for mycotoxin sensors. Anal Bioanal Chem 2017; 410:747-771. [PMID: 29127461 DOI: 10.1007/s00216-017-0701-3] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/05/2017] [Accepted: 10/10/2017] [Indexed: 12/16/2022]
Abstract
Mycotoxins are low molecular weight molecules produced as secondary metabolites by filamentous fungi that can be found as natural contaminants in many foods and feeds. These toxins have been shown to have adverse effects on both human and animal health, and are the cause of significant economic losses worldwide. Sensors for mycotoxin analysis have traditionally applied elements of biological origin for the selective recognition purposes. However, since the 1970s there has been an exponential growth in the use of genetically engineered or synthetic biomimetic recognition elements that allow some of the limitations associated with the use of natural receptors for the analyses of these toxins to be circumvented. This review provides an overview of recent advances in the application of bioinspired recognition elements, including recombinant antibodies, peptides, aptamers, and molecularly imprinted polymers, to the development of sensors for mycotoxins based on different transduction elements. Graphical abstract Novel analytical methods based on bioinspired recognition elements, such as recombinant antibodies, peptides, aptamers, and molecularly imprinted polymers, can improve the detection of mycotoxins and provide better tools than their natural counterparts to ensure food safety.
Collapse
Affiliation(s)
- Riikka Peltomaa
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Av. Complutense s/n, 28040, Madrid, Spain
| | - Elena Benito-Peña
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Av. Complutense s/n, 28040, Madrid, Spain
| | - María C Moreno-Bondi
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Av. Complutense s/n, 28040, Madrid, Spain.
| |
Collapse
|
17
|
Knutsen HK, Alexander J, Barregård L, Bignami M, Brüschweiler B, Ceccatelli S, Cottrill B, Dinovi M, Grasl-Kraupp B, Hogstrand C, Hoogenboom LR, Nebbia CS, Oswald IP, Petersen A, Rose M, Roudot AC, Schwerdtle T, Vleminckx C, Vollmer G, Wallace H, De Saeger S, Eriksen GS, Farmer P, Fremy JM, Gong YY, Meyer K, Naegeli H, Parent-Massin D, Rietjens I, van Egmond H, Altieri A, Eskola M, Gergelova P, Ramos Bordajandi L, Benkova B, Dörr B, Gkrillas A, Gustavsson N, van Manen M, Edler L. Risks to human and animal health related to the presence of deoxynivalenol and its acetylated and modified forms in food and feed. EFSA J 2017; 15:e04718. [PMID: 32625635 PMCID: PMC7010102 DOI: 10.2903/j.efsa.2017.4718] [Citation(s) in RCA: 155] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Deoxynivalenol (DON) is a mycotoxin primarily produced by Fusarium fungi, occurring predominantly in cereal grains. Following the request of the European Commission, the CONTAM Panel assessed the risk to animal and human health related to DON, 3-acetyl-DON (3-Ac-DON), 15-acetyl-DON (15-Ac-DON) and DON-3-glucoside in food and feed. A total of 27,537, 13,892, 7,270 and 2,266 analytical data for DON, 3-Ac-DON, 15-Ac-DON and DON-3-glucoside, respectively, in food, feed and unprocessed grains collected from 2007 to 2014 were used. For human exposure, grains and grain-based products were main sources, whereas in farm and companion animals, cereal grains, cereal by-products and forage maize contributed most. DON is rapidly absorbed, distributed, and excreted. Since 3-Ac-DON and 15-Ac-DON are largely deacetylated and DON-3-glucoside cleaved in the intestines the same toxic effects as DON can be expected. The TDI of 1 μg/kg bw per day, that was established for DON based on reduced body weight gain in mice, was therefore used as a group-TDI for the sum of DON, 3-Ac-DON, 15-Ac-DON and DON-3-glucoside. In order to assess acute human health risk, epidemiological data from mycotoxicoses were assessed and a group-ARfD of 8 μg/kg bw per eating occasion was calculated. Estimates of acute dietary exposures were below this dose and did not raise a health concern in humans. The estimated mean chronic dietary exposure was above the group-TDI in infants, toddlers and other children, and at high exposure also in adolescents and adults, indicating a potential health concern. Based on estimated mean dietary concentrations in ruminants, poultry, rabbits, dogs and cats, most farmed fish species and horses, adverse effects are not expected. At the high dietary concentrations, there is a potential risk for chronic adverse effects in pigs and fish and for acute adverse effects in cats and farmed mink.
Collapse
|
18
|
Deng Q, Qiu M, Wang Y, Lv P, Wu C, Sun L, Ye R, Xu D, Liu Y, Gooneratne R. A sensitive and validated immunomagnetic-bead based enzyme-linked immunosorbent assay for analyzing total T-2 (free and modified) toxins in shrimp tissues. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2017; 142:441-447. [PMID: 28458227 DOI: 10.1016/j.ecoenv.2017.04.037] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 04/05/2017] [Accepted: 04/17/2017] [Indexed: 06/07/2023]
Abstract
Accurate analyses of total T-2 (free and modified) in aquatic organisms including shrimp are important as the hazard caused by T-2 has been caught increasing attention. Therefore, acurate analysis of free T-2 especially of modified T-2 in shrimp tissues is important. A rapid, sensitive, and validated method for quantitative determination of free T-2 and modified T-2 toxin was developed using immunomagnetic-bead based enzyme-linked immunosorbent assay (IMB-ELISA). Super paramagnetic particles with a carboxyl group activated by an ester method coupled with envelope antigen 3- acetylneosolaniol- hemisuccinate - ovalbumin (3-Ac-NEOS-HS-OVA) was used to form immunomagnetic beads which could bind to T-2 skeletal structure antibodies. The conditions for magnetic bead coating of T-2 skeletal structure antibodies, and the concentrations of the polyclonal antibody and HRP-labeled goat anti-rabbit antibody were optimized. A good linear relationship with T-2 concentrations ranging from 5-75ng/mL (R2 =0.9965) was observed. The detection limit of different shrimp tissues of the IMB-ELISA ranged from 2.53 to 3.20ng/mL. And the IC50 was 63ng/mL. The recovery varied from 86% to 99% with a standard deviation of 2.8-5.8%. The application of this method to study the distribution in tissues showed that the total T-2 concentration in hepatopancreas was 26.7µg/kg > blood > head > muscle in the highest dose group of 12.2mg/kg. Our research showed a combination of ELISA and immunomagnetic bead technology provide a new, convenient approach to significantly improve the accuracy and sensitivity of total T-2 measurement in shrimp tissues.
Collapse
Affiliation(s)
- Qi Deng
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Mei Qiu
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China; National Marine Products Quality Supervision and Inspection Centre, Zhanjiang 524096, China
| | - Yaling Wang
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China.
| | - Pengli Lv
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Chaojin Wu
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Lijun Sun
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China.
| | - Riying Ye
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Defeng Xu
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Ying Liu
- College of Food Science and Technology, Guangdong Ocean University, Guangdong Provincial Key Laboratory of Aquatic Product Processing and Safety, Key Laboratory of Advanced Processing of Aquatic Products of Guangdong Higher Education Institution, Zhanjiang 524088, China
| | - Ravi Gooneratne
- Centre for Food Research and Innovation Centre for Food Research and Innovations, P.O. Box 85084, Lincoln University, Lincoln 7647, New Zealand
| |
Collapse
|
19
|
Ji F, Mokoena MP, Zhao H, Olaniran AO, Shi J. Development of an immunochromatographic strip test for the rapid detection of zearalenone in wheat from Jiangsu province, China. PLoS One 2017; 12:e0175282. [PMID: 28489899 PMCID: PMC5425148 DOI: 10.1371/journal.pone.0175282] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Accepted: 03/23/2017] [Indexed: 11/18/2022] Open
Abstract
A colloidal gold (ICS) test was developed for rapid detection of zearalenone (ZEN) in wheat samples. The mAb against ZEN was prepared in our laboratory and labelled with colloidal gold as a probe for the ICS test. The conditions were optimized and 30 nm colloidal gold nanoparticles were chosen for optimal performance. Millipore 135 was chosen as the NC membrane for its level of sensitivity. The optimum amount of coated antigen ZEN-OVA and anti-ZEN mAb was 0.5 mg/mL and 8 μg/mL, respectively. The ICS test, which has a detection limit of 15 ng/mL for ZEN, could be completed in 5 min. Analysis of ZEN in 202 wheat samples over three consecutive years revealed that data obtained from the ICS test were in a good agreement with LC-MS/MS data. This result demonstrated that the ICS test could be used as a qualitative tool to screen on-site for ZEN.
Collapse
Affiliation(s)
- Fang Ji
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding/Key Laboratory of Control Technology and Standard for Agro-Product Safety and Quality/Key Laboratory of Agro-Product Safety Risk Evaluation (Nanjing), Ministry of Agriculture, China/ Institute of Food Quality and Safety, Jiangsu Academy of Agricultural Sciences, Nanjing, China
- University of KwaZulu-Natal, Discipline Microbiology, School of Life Sciences, Westville Campus, Private Bag X54001, Durban, South Africa
- Collaborative Innovation Center for Modern Grain Circulation and Safety, Nanjing, China
| | - Mduduzi P. Mokoena
- University of KwaZulu-Natal, Discipline Microbiology, School of Life Sciences, Westville Campus, Private Bag X54001, Durban, South Africa
| | - Hongyan Zhao
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding/Key Laboratory of Control Technology and Standard for Agro-Product Safety and Quality/Key Laboratory of Agro-Product Safety Risk Evaluation (Nanjing), Ministry of Agriculture, China/ Institute of Food Quality and Safety, Jiangsu Academy of Agricultural Sciences, Nanjing, China
| | - Ademola O. Olaniran
- University of KwaZulu-Natal, Discipline Microbiology, School of Life Sciences, Westville Campus, Private Bag X54001, Durban, South Africa
| | - Jianrong Shi
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding/Key Laboratory of Control Technology and Standard for Agro-Product Safety and Quality/Key Laboratory of Agro-Product Safety Risk Evaluation (Nanjing), Ministry of Agriculture, China/ Institute of Food Quality and Safety, Jiangsu Academy of Agricultural Sciences, Nanjing, China
- Collaborative Innovation Center for Modern Grain Circulation and Safety, Nanjing, China
- * E-mail:
| |
Collapse
|
20
|
|
21
|
Li L, Xia LR, Zhao YF, Wang HY. Development of immune-affinity 96 spots monolith array for multiple mycotoxins detection in food samples. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1029-1030:72-80. [DOI: 10.1016/j.jchromb.2016.07.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 05/16/2016] [Accepted: 07/06/2016] [Indexed: 12/22/2022]
|
22
|
Lu L, Seenivasan R, Wang YC, Yu JH, Gunasekaran S. An Electrochemical Immunosensor for Rapid and Sensitive Detection of Mycotoxins Fumonisin B1 and Deoxynivalenol. Electrochim Acta 2016. [DOI: 10.1016/j.electacta.2016.07.096] [Citation(s) in RCA: 84] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
23
|
Mycotoxin Determination in Foods Using Advanced Sensors Based on Antibodies or Aptamers. Toxins (Basel) 2016; 8:toxins8080239. [PMID: 27529281 PMCID: PMC4999855 DOI: 10.3390/toxins8080239] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 07/08/2016] [Accepted: 07/08/2016] [Indexed: 12/24/2022] Open
Abstract
Mycotoxin contamination threatens health and life of humans and animals throughout the food supply chains. Many of the mycotoxins have been proven to be carcinogens, teratogens and mutagens. The reliable and sensitive sensing methods are requested to monitor mycotoxin contamination. Advanced sensors based on antibodies or aptamers boast the advantages of high sensitivity and rapidity, and have been used in the mycotoxin sensing. These sensors are miniaturized, thereby lowering costs, and are applicable to high-throughput modes. In this work, the latest developments in sensing strategies for mycotoxin determination were critically discussed. Optical and electrochemical sensing modes were compared. The sensing methods for single mycotoxin or multiple mycotoxins in food samples were reviewed, along with the challenges and the future of antibody or aptamer-based sensors. This work might promote academic studies and industrial applications for mycotoxin sensing.
Collapse
|
24
|
Catanante G, Rhouati A, Hayat A, Marty JL. An Overview of Recent Electrochemical Immunosensing Strategies for Mycotoxins Detection. ELECTROANAL 2016. [DOI: 10.1002/elan.201600181] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Gaelle Catanante
- BAE: Biocapteurs-Analyses-Environnement; Universite de Perpignan Via Domitia; 52 Avenue Paul Alduy Perpignan Cedex 66860 France
| | - Amina Rhouati
- BAE: Biocapteurs-Analyses-Environnement; Universite de Perpignan Via Domitia; 52 Avenue Paul Alduy Perpignan Cedex 66860 France
- Ecole Nationale Supérieure de Biotechnologie; Constantine-Algérie
| | - Akhtar Hayat
- Interdisciplinary Research centre in Biomedical Materials (IRCBM); COMSATS Institute of Information technology; Lahore Pakistan
| | - Jean Louis Marty
- BAE: Biocapteurs-Analyses-Environnement; Universite de Perpignan Via Domitia; 52 Avenue Paul Alduy Perpignan Cedex 66860 France
| |
Collapse
|
25
|
Duffy GF, Moore EJ. Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments. ANAL LETT 2016. [DOI: 10.1080/00032719.2016.1167900] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
26
|
Bazin I, Tria SA, Hayat A, Marty JL. New biorecognition molecules in biosensors for the detection of toxins. Biosens Bioelectron 2016; 87:285-298. [PMID: 27568847 DOI: 10.1016/j.bios.2016.06.083] [Citation(s) in RCA: 105] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 06/17/2016] [Accepted: 06/28/2016] [Indexed: 12/24/2022]
Abstract
Biological and synthetic recognition elements are at the heart of the majority of modern bioreceptor assays. Traditionally, enzymes and antibodies have been integrated in the biosensor designs as a popular choice for the detection of toxin molecules. But since 1970s, alternative biological and synthetic binders have been emerged as a promising alternative to conventional biorecognition elements in detection systems for laboratory and field-based applications. Recent research has witnessed immense interest in the use of recombinant enzymatic methodologies and nanozymes to circumvent the drawbacks associated with natural enzymes. In the area of antibody production, technologies based on the modification of in vivo synthesized materials and in vitro approaches with development of "display "systems have been introduced in the recent years. Subsequently, molecularly-imprinted polymers and Peptide nucleic acid (PNAs) were developed as an attractive receptor with applications in the area of sample preparation and detection systems. In this article, we discuss all alternatives to conventional biomolecules employed in the detection of various toxin molecules We review recent developments in modified enzymes, nanozymes, nanobodies, aptamers, peptides, protein scaffolds and DNazymes. With the advent of nanostructures and new interface materials, these recognition elements will be major players in future biosensor development.
Collapse
Affiliation(s)
- Ingrid Bazin
- École des Mines d'Alès, 6 Avenuede Clavières, 30100 Alès Cedex, France.
| | - Scherrine A Tria
- École des Mines d'Alès, 6 Avenuede Clavières, 30100 Alès Cedex, France
| | - Akhtar Hayat
- BAE (Biocapteurs-Analyses-Environnement), Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan Cedex 66860, France; Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology (CIIT), Lahore, Pakistan
| | - Jean-Louis Marty
- BAE (Biocapteurs-Analyses-Environnement), Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan Cedex 66860, France
| |
Collapse
|
27
|
Qing Y, Li C, Yang X, Zhou X, Xue J, Luo M, Xu X, Chen S, Qiu J. Electrochemical immunosensor using single-walled carbon nanotubes/chitosan for ultrasensitive detection of deoxynivalenol in food samples. J APPL ELECTROCHEM 2016. [DOI: 10.1007/s10800-016-0984-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
28
|
Advances in Biosensors, Chemosensors and Assays for the Determination of Fusarium Mycotoxins. Toxins (Basel) 2016; 8:toxins8060161. [PMID: 27231937 PMCID: PMC4926128 DOI: 10.3390/toxins8060161] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2016] [Revised: 05/07/2016] [Accepted: 05/16/2016] [Indexed: 01/06/2023] Open
Abstract
The contaminations of Fusarium mycotoxins in grains and related products, and the exposure in human body are considerable concerns in food safety and human health worldwide. The common Fusarium mycotoxins include fumonisins, T-2 toxin, deoxynivalenol and zearalenone. For this reason, simple, fast and sensitive analytical techniques are particularly important for the screening and determination of Fusarium mycotoxins. In this review, we outlined the related advances in biosensors, chemosensors and assays based on the classical and novel recognition elements such as antibodies, aptamers and molecularly imprinted polymers. Application to food/feed commodities, limit and time of detection were also discussed.
Collapse
|
29
|
Biosensor-Based Technologies for the Detection of Pathogens and Toxins. BIOSENSORS FOR SUSTAINABLE FOOD - NEW OPPORTUNITIES AND TECHNICAL CHALLENGES 2016. [DOI: 10.1016/bs.coac.2016.04.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
30
|
Reverté L, Prieto-Simón B, Campàs M. New advances in electrochemical biosensors for the detection of toxins: Nanomaterials, magnetic beads and microfluidics systems. A review. Anal Chim Acta 2015; 908:8-21. [PMID: 26826685 DOI: 10.1016/j.aca.2015.11.050] [Citation(s) in RCA: 115] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Revised: 11/25/2015] [Accepted: 11/28/2015] [Indexed: 01/01/2023]
Abstract
The use of nanotechnology in bioanalytical devices has special advantages in the detection of toxins of interest in food safety and environmental applications. The low levels to be detected and the small size of toxins justify the increasing number of publications dealing with electrochemical biosensors, due to their high sensitivity and design versatility. The incorporation of nanomaterials in their development has been exploited to further increase their sensitivity, providing simple and fast devices, with multiplexed capabilities. This paper gives an overview of the electrochemical biosensors that have incorporated carbon and metal nanomaterials in their configurations for the detection of toxins. Biosensing systems based on magnetic beads or integrated into microfluidics systems have also been considered because of their contribution to the development of compact analytical devices. The roles of these materials, the methods used for their incorporation in the biosensor configurations as well as the advantages they provide to the analyses are summarised.
Collapse
Affiliation(s)
- Laia Reverté
- IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Beatriz Prieto-Simón
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Future Industries Institute, University of South Australia, SA 5095, Australia
| | - Mònica Campàs
- IRTA, Carretera Poble Nou km. 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain.
| |
Collapse
|
31
|
Qiu YL, He QH, Xu Y, Wang W, Liu YY. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis. Anal Bioanal Chem 2015; 408:895-903. [PMID: 26608283 DOI: 10.1007/s00216-015-9181-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Revised: 10/27/2015] [Accepted: 11/09/2015] [Indexed: 01/28/2023]
Abstract
A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.
Collapse
Affiliation(s)
- Yu-Lou Qiu
- State Key Laboratory of Food Science and Technology, Sino-German Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang, 330047, China
| | - Qing-Hua He
- State Key Laboratory of Food Science and Technology, Sino-German Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang, 330047, China.
| | - Yang Xu
- State Key Laboratory of Food Science and Technology, Sino-German Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang, 330047, China.
| | - Wei Wang
- State Key Laboratory of Food Science and Technology, Sino-German Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang, 330047, China
| | - Yuan-Yuan Liu
- State Key Laboratory of Food Science and Technology, Sino-German Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang, 330047, China
| |
Collapse
|
32
|
Volpe G, Delibato E, Fabiani L, Pucci E, Piermarini S, D'Angelo A, Capuano F, De Medici D, Palleschi G. Development and evaluation of an ELIME assay to reveal the presence of Salmonella in irrigation water: Comparison with Real-Time PCR and the Standard Culture Method. Talanta 2015; 149:202-210. [PMID: 26717832 DOI: 10.1016/j.talanta.2015.11.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Revised: 10/29/2015] [Accepted: 11/04/2015] [Indexed: 11/15/2022]
Abstract
A reliable, low-cost and easy-to-use ELIME (Enzyme-Linked-Immuno-Magnetic-Electrochemical) assay for detection of Salmonella enterica in irrigation water is presented. Magnetic beads (MBs), coupled to a strip of eight-magnetized screen-printed electrodes localized at the bottom of eight wells (8-well/SPE strip), effectively supported a sandwich immunological chain. Enzymatic by-product is quickly measured by chronoamperometry, using a portable instrument. With the goal of developing a method able to detect a wide range of Salmonella serotypes, including S. Napoli and S. Thompson strains responsible for various community alerts, different kinds of MBs, antibodies and blocking agents were tested. The final system employs MBs coated with a broad reactivity monoclonal antibody anti-salmonella and blocked with dry milk. For a simple and rapid assay these two steps were performed in a preliminary phase, while the two sequential incubations for the immuno-recognition events were merged in a single step of 1h. In parallel a Real-Time PCR (RTi-PCR) method, based on a specific locked nucleic acid (LNA) fluorescent probe and an internal amplification control (IAC), was carried out. The selectivity of the ELIME and RTi-PCR assays was proved by inclusivity and exclusivity tests performed analyzing different Salmonella serotypes and non-target microorganisms, most commonly isolated from environmental sources. Furthermore, both methods were applied to experimentally and not experimentally contaminated irrigation water samples. Results confirmed by the ISO culture method, demonstrated the effectiveness of ELIME and RTi-PCR assays to detect a low number of salmonella cells (1-10 CFU/L) reducing drastically the long analysis time usually required to reveal this pathogen.
Collapse
Affiliation(s)
- G Volpe
- Department of Chemical Science and Technologies, "Tor Vergata" University, Via della Ricerca Scientifica, Rome, Italy.
| | - E Delibato
- Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanità, Viale Regina Elena 299, Rome, Italy.
| | - L Fabiani
- Department of Chemical Science and Technologies, "Tor Vergata" University, Via della Ricerca Scientifica, Rome, Italy
| | - E Pucci
- Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanità, Viale Regina Elena 299, Rome, Italy
| | - S Piermarini
- Department of Chemical Science and Technologies, "Tor Vergata" University, Via della Ricerca Scientifica, Rome, Italy
| | - A D'Angelo
- Department of Environment and Primary Prevention, Istituto Superiore di Sanità, Viale Regina Elena 299, Rome, Italy
| | - F Capuano
- Department of Food Inspection, Istituto Zooprofilattico Sperimentale del Mezzogiorno, Via della Salute 2, Portici, NA, Italy
| | - D De Medici
- Department of Veterinary Public Health and Food Safety, Istituto Superiore di Sanità, Viale Regina Elena 299, Rome, Italy
| | - G Palleschi
- Department of Chemical Science and Technologies, "Tor Vergata" University, Via della Ricerca Scientifica, Rome, Italy
| |
Collapse
|
33
|
Lv X, Li Y, Yan T, Pang X, Cao W, Du B, Wu D, Wei Q. Electrochemiluminescence modified electrodes based on RuSi@Ru(bpy)32+ loaded with gold functioned nanoporous CO/Co3O4 for detection of mycotoxin deoxynivalenol. Biosens Bioelectron 2015; 70:28-33. [DOI: 10.1016/j.bios.2015.03.020] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Revised: 02/25/2015] [Accepted: 03/09/2015] [Indexed: 11/28/2022]
|
34
|
Biscay J, González García MB, García AC. Determination of Total PSA Using Magnetic Beads and a Re-usable Screen Printed Carbon Electrode Array. ELECTROANAL 2015. [DOI: 10.1002/elan.201500351] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Neves MMPS, González-García MB, Hernández-Santos D, Fanjul-Bolado P. Screen-Printed Electrochemical 96-Well Plate: a High-Throughput Platform for Multiple Analytical Applications. ELECTROANAL 2014. [DOI: 10.1002/elan.201400388] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
36
|
Hasanzadeh M, Shadjou N, Eskandani M, Soleymani J, Jafari F, de la Guardia M. Dendrimer-encapsulated and cored metal nanoparticles for electrochemical nanobiosensing. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2013.09.015] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
37
|
Zhan X, Tang W, Dou W, Zhao G. Disposable Immunosensor forEscherichia ColiO157:H7 Based on a Multi-Walled Carbon Nanotube-Sodium Alginate Nanocomposite Film Modified Screen-Printed Carbon Electrode. ANAL LETT 2013. [DOI: 10.1080/00032719.2013.811677] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
38
|
Kergaravat SV, Beltramino L, Garnero N, Trotta L, Wagener M, Isabel Pividori M, Hernandez SR. Electrochemical magneto immunosensor for the detection of anti-TG2 antibody in celiac disease. Biosens Bioelectron 2013; 48:203-9. [DOI: 10.1016/j.bios.2013.04.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2013] [Revised: 03/24/2013] [Accepted: 04/08/2013] [Indexed: 12/18/2022]
|
39
|
Development of electrochemical immunosensors towards point of care diagnostics. Biosens Bioelectron 2013; 47:1-11. [DOI: 10.1016/j.bios.2013.02.045] [Citation(s) in RCA: 172] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 02/27/2013] [Accepted: 02/28/2013] [Indexed: 12/21/2022]
|
40
|
Site-directed antibody immobilization techniques for immunosensors. Biosens Bioelectron 2013; 50:460-71. [PMID: 23911661 DOI: 10.1016/j.bios.2013.06.060] [Citation(s) in RCA: 197] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Revised: 06/14/2013] [Accepted: 06/26/2013] [Indexed: 02/07/2023]
Abstract
Immunosensor sensitivity, regenerability, and stability directly depend on the type of antibodies used for the immunosensor design, quantity of immobilized molecules, remaining activity upon immobilization, and proper orientation on the sensing interface. Although sensor surfaces prepared with antibodies immobilized in a random manner yield satisfactory results, site-directed immobilization of the sensing molecules significantly improves the immunosensor sensitivity, especially when planar supports are employed. This review focuses on the three most conventional site-directed antibody immobilization techniques used in immunosensor design. One strategy of immobilizing antibodies on the sensor surface is via affinity interactions with a pre-formed layer of the Fc binding proteins, e.g., protein A, protein G, Fc region specific antibodies or various recombinant proteins. Another immobilization strategy is based on the use of chemically or genetically engineered antibody fragments that can be attached to the sensor surface covered in gold or self-assembled monolayer via the sulfhydryl groups present in the hinge region. The third most common strategy is antibody immobilization via an oxidized oligosaccharide moiety present in the Fc region of the antibody. The principles, advantages, applications, and arising problems of these most often applied immobilization techniques are reviewed.
Collapse
|
41
|
Electrochemical affinity biosensors for detection of mycotoxins: A review. Biosens Bioelectron 2013; 49:146-58. [PMID: 23743326 DOI: 10.1016/j.bios.2013.05.008] [Citation(s) in RCA: 195] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2013] [Revised: 04/26/2013] [Accepted: 05/02/2013] [Indexed: 11/22/2022]
Abstract
This review discusses the current state of electrochemical biosensors in the determination of mycotoxins in foods. Mycotoxins are highly toxic secondary metabolites produced by molds. The acute toxicity of these results in serious human and animal health problems, although it has been only since early 1960s when the first studied aflatoxins were found to be carcinogenic. Mycotoxins affect a broad range of agricultural products, most important cereals and cereal-based foods. A majority of countries, mentioning especially the European Union, have established preventive programs to control contamination and strict laws of the permitted levels in foods. Official methods of analysis of mycotoxins normally requires sophisticated instrumentation, e.g. liquid chromatography with fluorescence or mass detectors, combined with extraction procedures for sample preparation. For about sixteen years, the use of simpler and faster analytical procedures based on affinity biosensors has emerged in scientific literature as a very promising alternative, particularly electrochemical (i.e., amperometric, impedance, potentiometric or conductimetric) affinity biosensors due to their simplicity and sensitivity. Typically, electrochemical biosensors for mycotoxins use specific antibodies or aptamers as affinity ligands, although recombinant antibodies, artificial receptors and molecular imprinted polymers show potential utility. This article deals with recent advances in electrochemical affinity biosensors for mycotoxins and covers complete literature from the first reports about sixteen years ago.
Collapse
|
42
|
Ricci F, Adornetto G, Palleschi G. A review of experimental aspects of electrochemical immunosensors. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.06.033] [Citation(s) in RCA: 225] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
43
|
Towards the development of a single-step immunosensor based on an electrochemical screen-printed electrode strip coupled with immunomagnetic beads. Anal Bioanal Chem 2012; 405:655-63. [DOI: 10.1007/s00216-012-6141-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2012] [Revised: 05/17/2012] [Accepted: 05/23/2012] [Indexed: 10/28/2022]
|
44
|
Meneely J, Quinn J, Flood E, Hajšlová J, Elliott C. Simultaneous screening for T-2/HT-2 and deoxynivalenol in cereals using a surface plasmon resonance immunoassay. WORLD MYCOTOXIN J 2012. [DOI: 10.3920/wmj2011.1351] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
This manuscript describes a rapid surface plasmon resonance (SPR) immunoassay for the simultaneous determination of the sum of T-2/HT-2 toxins (T-2/HT-2) and deoxynivalenol (DON), in cereals and cereal-based products. The assay is based on an inhibition format employing a monoclonal antibody raised against HT-2 with cross reactivity to T-2 and a polyclonal antibody raised against DON, thereby enabling the detection of the three trichothecene mycotoxins (types A and B). The surface chemistry involved an equal mixture of HT-2 and DON covalently coupled onto a high capacity COOH5 sensor chip. Using the specified antibodies and a mixed toxin sensor surface, and running calibration curves (HT-2 and DON) and samples in parallel it has been proven that it is feasible to develop a multiplex assay on this SPR platform. In-house validation has shown limits of detection of 12, 1 and 29 μg/kg for DON and 31, 47 and 36 μg/kg for HT-2 in wheat, breakfast cereal and maize-based baby food, respectively. Both intra-assay and inter-assay precision were calculated using fortified DON and HT-2 samples. Durum wheat, wheatbased breakfast cereal and maize-based baby food were spiked at various concentration levels and the coefficients of variation calculated ranged from 1.1% to 9.9% for DON and from 1.4% to 11.3% for HT-2. A high correlation was observed between the screening assay and confirmatory mass spectrometry.
Collapse
Affiliation(s)
- J.P. Meneely
- Institute of Agri-Food and Land Use, Queen's University Belfast, David Keir Building, Stranmillis Road, Belfast, BT9 5AG, United Kingdom
| | - J.G. Quinn
- FLIR/ICx Nomadics Bioinstrumentation Group, 800 Research Parkway, Suite 100, Oklahoma City, OK 73104-3623, USA
| | - E.M. Flood
- FLIR/ICx Nomadics Bioinstrumentation Group, 800 Research Parkway, Suite 100, Oklahoma City, OK 73104-3623, USA
| | - J. Hajšlová
- Department of Food Chemistry and Analysis, Institute of Chemical Technology, Technicka 3, 16628 Prague, Czech Republic
| | - C.T. Elliott
- Institute of Agri-Food and Land Use, Queen's University Belfast, David Keir Building, Stranmillis Road, Belfast, BT9 5AG, United Kingdom
| |
Collapse
|
45
|
Campàs M, Garibo D, Prieto-Simón B. Novel nanobiotechnological concepts in electrochemical biosensors for the analysis of toxins. Analyst 2012; 137:1055-67. [DOI: 10.1039/c2an15736e] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
46
|
Recombinant antibodies and their use in biosensors. Anal Bioanal Chem 2011; 402:3027-38. [PMID: 22159424 DOI: 10.1007/s00216-011-5569-z] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2011] [Revised: 11/04/2011] [Accepted: 11/09/2011] [Indexed: 12/24/2022]
Abstract
Inexpensive, noninvasive immunoassays can be used to quickly detect disease in humans. Immunoassay sensitivity and specificity are decidedly dependent upon high-affinity, antigen-specific antibodies. Antibodies are produced biologically. As such, antibody quality and suitability for use in immunoassays cannot be readily determined or controlled by human intervention. However, the process through which high-quality antibodies can be obtained has been shortened and streamlined by use of genetic engineering and recombinant antibody techniques. Antibodies that traditionally take several months or more to produce when animals are used can now be developed in a few weeks as recombinant antibodies produced in bacteria, yeast, or other cell types. Typically most immunoassays use two or more antibodies or antibody fragments to detect antigens that are indicators of disease. However, a label-free biosensor, for example, a quartz-crystal microbalance (QCM) needs one antibody only. As such, the cost and time needed to design and develop an immunoassay can be substantially reduced if recombinant antibodies and biosensors are used rather than traditional antibody and assay (e.g. enzyme-linked immunosorbant assay, ELISA) methods. Unlike traditional antibodies, recombinant antibodies can be genetically engineered to self-assemble on biosensor surfaces, at high density, and correctly oriented to enhance antigen-binding activity and to increase assay sensitivity, specificity, and stability. Additionally, biosensor surface chemistry and physical and electronic properties can be modified to further increase immunoassay performance above and beyond that obtained by use of traditional methods. This review describes some of the techniques investigators have used to develop highly specific and sensitive, recombinant antibody-based biosensors for detection of antigens in simple or complex biological samples.
Collapse
|
47
|
Pedrero M, Campuzano S, Pingarrón JM. Magnetic Beads-Based Electrochemical Sensors Applied to the Detection and Quantification of Bioterrorism/Biohazard Agents. ELECTROANAL 2011; 24:470-482. [PMID: 32313410 PMCID: PMC7163718 DOI: 10.1002/elan.201100528] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Accepted: 10/05/2011] [Indexed: 11/12/2022]
Abstract
Nowadays, detecting the presence of bioterrorism and biohazard agents in environmental and food samples is of great concern, due to their toxicity, and because many of them are prone to be used in terrorism attacks. The use of functionalized magnetic beads (MBs) in the development of electrochemical immuno- and genosensors has resulted in innovative and powerful detection strategies that may be applied to environmental, food and clinical analysis. This review describes current research on the combination of functionalized MBs with electrochemical detection for the development of magnetobiosensors applied to rapid, sensitive and specific detection of bioterrorism and biohazard agents.
Collapse
Affiliation(s)
- María Pedrero
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| | - Susana Campuzano
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| | - José M Pingarrón
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| |
Collapse
|
48
|
Mi Q, Wang ZW, Chai CY, Zhang J, Zhao B, Chen CY. Multilayer structured immunosensor based on a glassy carbon electrode modified with multi-wall carbon nanotubes, polythionine, and gold nanoparticles. Mikrochim Acta 2011. [DOI: 10.1007/s00604-011-0572-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
49
|
Shephard G, Berthiller F, Burdaspal P, Crews C, Jonker M, Krska R, MacDonald S, Malone B, Maragos C, Sabino M, Solfrizzo M, van Egmond H, Whitaker T. Developments in mycotoxin analysis: an update for 2009-2010. WORLD MYCOTOXIN J 2011. [DOI: 10.3920/wmj2010.1249] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
This review highlights developments in mycotoxin analysis and sampling over a period between mid-2009 and mid-2010. It covers the major mycotoxins aflatoxins, Alternaria toxins, ergot alkaloids, fumonisins, ochratoxin, patulin, trichothecenes, and zearalenone. New and improved methods for mycotoxins continue to be published. Immunological-based method developments continue to be of wide interest in a broad range of formats. Multimycotoxin determination by LC-MS/MS is now being targeted at the specific ranges of mycotoxins and matrices of interest or concern to the individual laboratory. Although falling outside the main emphasis of the review, some aspects of natural occurrence have been mentioned, especially if linked to novel method developments.
Collapse
Affiliation(s)
- G. Shephard
- PROMEC Unit, Medical Research Council, P.O. Box 19070, Tygerberg 7505, South Africa
| | - F. Berthiller
- Department for Agrobiotechnology (IFA-Tulln), University of Natural Resources and Applied Life Sciences Vienna, Center for Analytical Chemistry, Christian Doppler Laboratory for Mycotoxin Research, Konrad Lorenz Str. 20, 3430 Tulln, Austria
| | - P. Burdaspal
- National Centre for Food, Spanish Food Safety and Nutrition Agency, Carretera a Pozuelo Km 5.1, 28220 Majadahonda (Madrid), Spain
| | - C. Crews
- The Food and Environment Research Agency, Sand Hutton, York YO41 1LZ, United Kingdom
| | - M. Jonker
- RIKILT Institute of Food Safety, Cluster Natural Toxins & Pesticides, P.O. Box 230, 6700 AE Wageningen, The Netherlands
| | - R. Krska
- Department for Agrobiotechnology (IFA-Tulln), University of Natural Resources and Applied Life Sciences Vienna, Center for Analytical Chemistry, Christian Doppler Laboratory for Mycotoxin Research, Konrad Lorenz Str. 20, 3430 Tulln, Austria
| | - S. MacDonald
- The Food and Environment Research Agency, Sand Hutton, York YO41 1LZ, United Kingdom
| | - B. Malone
- Trilogy Analytical Laboratory, 870 Vossbrink Drive, Washington, MO 63090, USA
| | - C. Maragos
- USDA, ARS, National Center for Agricultural Utilization Research, 1815 N. University St, Peoria, IL 61604, USA
| | - M. Sabino
- Instituto Adolfo Lutz, Av Dr Arnaldo 355, 01246-902 São Paulo/SP, Brazil
| | - M. Solfrizzo
- Institute of Sciences of Food Production, National Research Council, Via Amendola 122/o, 70126 Bari, Italy
| | - H. van Egmond
- RIKILT Institute of Food Safety, Cluster Natural Toxins & Pesticides, P.O. Box 230, 6700 AE Wageningen, The Netherlands
| | - T. Whitaker
- Biological and Agricultural Engineering Department, N.C. State University, P.O. Box 7625, Raleigh, NC 27695-7625, USA
| |
Collapse
|
50
|
Meneely J, Ricci F, Vesco S, Abouzied M, Sulyok M, Krska R, Elliott C. A comparative study of qualitative immunochemical screening assays for the combined measurement of T-2/HT-2 in cereals and cereal-based products. WORLD MYCOTOXIN J 2011. [DOI: 10.3920/wmj2011.1313] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzymelinked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.
Collapse
Affiliation(s)
- J. Meneely
- Institute of Agri-Food and Land Use, Queen's University Belfast, David Keir Building, Stranmillis Road, Belfast, BT9 5AG, United Kingdom
| | - F. Ricci
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy
| | - S. Vesco
- Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy
| | - M. Abouzied
- Neogen Corporation, 620 Lesher Place, Lansing MI 48912, USA
| | - M. Sulyok
- Department IFA-Tulln, University of Natural Resources and Life Sciences, Konrad Lorenzstr. 20, 3430 Tulln, Austria
| | - R. Krska
- Department IFA-Tulln, University of Natural Resources and Life Sciences, Konrad Lorenzstr. 20, 3430 Tulln, Austria
| | - C. Elliott
- Institute of Agri-Food and Land Use, Queen's University Belfast, David Keir Building, Stranmillis Road, Belfast, BT9 5AG, United Kingdom
| |
Collapse
|