1
|
Ummalyma SB, Bhaskar T. Recent advances in the role of biocatalyst in biofuel cells and its application: An overview. Biotechnol Genet Eng Rev 2024; 40:2051-2089. [PMID: 37010302 DOI: 10.1080/02648725.2023.2197715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 03/09/2023] [Indexed: 04/04/2023]
Abstract
Biofuel cells have recently gained popularity as a green and renewable energy source. Biofuel cells are unique devices of energy and are capable of converting the stored chemical energy from waste materials such as pollutants, organics and wastewater into reliable, renewable, pollution-free energy sources through the action of biocatalysts such as various microorganisms and enzymes. It is a promising technological device to treat waste to compensate for global warming and the energy crisis through the green energy production process. Due to their unique properties, various potential biocatalysts are attracting researchers to apply them to various microbial biofuel cells for improving electricity and power. Recent research in biofuel cells is focusing on the exploitation of different biocatalysts and how they are enhancing power generation for various applications in the field of environmental technology, and biomedical fields such as implantable devices, testing kits, and biosensors. This review focusing the importance of microbial fuel cells (MFCs) and enzymatic fuel cells (ECFs) and role of different types of biocatalysts and their mechanisms for improving biofuel cell efficiency gathered from recent reports. Finally, its multifaceted applications with special emphasis on environmental technology and biomedical field will be described, along with future perspectives.
Collapse
Affiliation(s)
- Sabeela Beevi Ummalyma
- Department of Biotechnology, Govt. of India Takyelpat, Institute of Bioresources and Sustainable Development (IBSD)An Autonomous Institute, Imphal, India
| | - Thallada Bhaskar
- Material Resource Efficiency Division, CSIR-Indian Institute of Petroleum, Dehradun, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| |
Collapse
|
2
|
Sowa K, Okuda-Shimazaki J, Fukawa E, Sode K. Direct Electron Transfer-Type Oxidoreductases for Biomedical Applications. Annu Rev Biomed Eng 2024; 26:357-382. [PMID: 38424090 DOI: 10.1146/annurev-bioeng-110222-101926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Among the various types of enzyme-based biosensors, sensors utilizing enzymes capable of direct electron transfer (DET) are recognized as the most ideal. However, only a limited number of redox enzymes are capable of DET with electrodes, that is, dehydrogenases harboring a subunit or domain that functions specifically to accept electrons from the redox cofactor of the catalytic site and transfer the electrons to the external electron acceptor. Such subunits or domains act as built-in mediators for electron transfer between enzymes and electrodes; consequently, such enzymes enable direct electron transfer to electrodes and are designated as DET-type enzymes. DET-type enzymes fall into several categories, including redox cofactors of catalytic reactions, built-in mediators for DET with electrodes and by their protein hierarchic structures, DET-type oxidoreductases with oligomeric structures harboring electron transfer subunits, and monomeric DET-type oxidoreductases harboring electron transfer domains. In this review, we cover the science of DET-type oxidoreductases and their biomedical applications. First, we introduce the structural biology and current understanding of DET-type enzyme reactions. Next, we describe recent technological developments based on DET-type enzymes for biomedical applications, such as biosensors and biochemical energy harvesting for self-powered medical devices. Finally, after discussing how to further engineer and create DET-type enzymes, we address the future prospects for DET-type enzymes in biomedical engineering.
Collapse
Affiliation(s)
- Keisei Sowa
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University, Sakyo, Kyoto, Japan
| | - Junko Okuda-Shimazaki
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, Kogane, Tokyo, Japan
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA;
| | - Eole Fukawa
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University, Sakyo, Kyoto, Japan
| | - Koji Sode
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA;
| |
Collapse
|
3
|
Yue O, Wang X, Xie L, Bai Z, Zou X, Liu X. Biomimetic Exogenous "Tissue Batteries" as Artificial Power Sources for Implantable Bioelectronic Devices Manufacturing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307369. [PMID: 38196276 PMCID: PMC10953594 DOI: 10.1002/advs.202307369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/27/2023] [Indexed: 01/11/2024]
Abstract
Implantable bioelectronic devices (IBDs) have gained attention for their capacity to conformably detect physiological and pathological signals and further provide internal therapy. However, traditional power sources integrated into these IBDs possess intricate limitations such as bulkiness, rigidity, and biotoxicity. Recently, artificial "tissue batteries" (ATBs) have diffusely developed as artificial power sources for IBDs manufacturing, enabling comprehensive biological-activity monitoring, diagnosis, and therapy. ATBs are on-demand and designed to accommodate the soft and confining curved placement space of organisms, minimizing interface discrepancies, and providing ample power for clinical applications. This review presents the near-term advancements in ATBs, with a focus on their miniaturization, flexibility, biodegradability, and power density. Furthermore, it delves into material-screening, structural-design, and energy density across three distinct categories of TBs, distinguished by power supply strategies. These types encompass innovative energy storage devices (chemical batteries and supercapacitors), power conversion devices that harness power from human-body (biofuel cells, thermoelectric nanogenerators, bio-potential devices, piezoelectric harvesters, and triboelectric devices), and energy transfer devices that receive and utilize external energy (radiofrequency-ultrasound energy harvesters, ultrasound-induced energy harvesters, and photovoltaic devices). Ultimately, future challenges and prospects emphasize ATBs with the indispensability of bio-safety, flexibility, and high-volume energy density as crucial components in long-term implantable bioelectronic devices.
Collapse
Affiliation(s)
- Ouyang Yue
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xuechuan Wang
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Long Xie
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Zhongxue Bai
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xiaoliang Zou
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xinhua Liu
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| |
Collapse
|
4
|
Garland NT, Kaveti R, Bandodkar AJ. Biofluid-Activated Biofuel Cells, Batteries, and Supercapacitors: A Comprehensive Review. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2303197. [PMID: 37358398 DOI: 10.1002/adma.202303197] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/06/2023] [Indexed: 06/27/2023]
Abstract
Recent developments in wearable and implanted devices have resulted in numerous, unprecedented capabilities that generate increasingly detailed information about a user's health or provide targeted therapy. However, options for powering such systems remain limited to conventional batteries which are large and have toxic components and as such are not suitable for close integration with the human body. This work provides an in-depth overview of biofluid-activated electrochemical energy devices, an emerging class of energy sources judiciously designed for biomedical applications. These unconventional energy devices are composed of biocompatible materials that harness the inherent chemistries of various biofluids to produce useable electrical energy. This work covers examples of such biofluid-activated energy devices in the form of biofuel cells, batteries, and supercapacitors. Advances in materials, design engineering, and biotechnology that form the basis for high-performance, biofluid-activated energy devices are discussed. Innovations in hybrid manufacturing and heterogeneous integration of device components to maximize power output are also included. Finally, key challenges and future scopes of this nascent field are provided.
Collapse
Affiliation(s)
- Nate T Garland
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Rajaram Kaveti
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Amay J Bandodkar
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| |
Collapse
|
5
|
Seo H, Chung WG, Kwon YW, Kim S, Hong YM, Park W, Kim E, Lee J, Lee S, Kim M, Lim K, Jeong I, Song H, Park JU. Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management. Chem Rev 2023; 123:11488-11558. [PMID: 37748126 PMCID: PMC10571045 DOI: 10.1021/acs.chemrev.3c00290] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Indexed: 09/27/2023]
Abstract
The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.
Collapse
Affiliation(s)
- Hunkyu Seo
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Won Gi Chung
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Yong Won Kwon
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Sumin Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Yeon-Mi Hong
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Wonjung Park
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Enji Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Jakyoung Lee
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Sanghoon Lee
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Moohyun Kim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Kyeonghee Lim
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Inhea Jeong
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Hayoung Song
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
| | - Jang-Ung Park
- Department
of Materials Science and Engineering, Yonsei
University, Seoul 03722, Republic
of Korea
- Department
of Neurosurgery, Yonsei University College
of Medicine, Seoul 03722, Republic of Korea
- Center
for Nanomedicine, Institute for Basic Science (IBS), Yonsei University, Seoul 03722, Republic
of Korea
| |
Collapse
|
6
|
Feng X, Ning Y, Wu Z, Li Z, Xu C, Li G, Hu Z. Defect-Enriched Graphene Nanoribbons Tune the Adsorption Behavior of the Mediator to Boost the Lactate/Oxygen Biofuel Cell. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1089. [PMID: 36985983 PMCID: PMC10058110 DOI: 10.3390/nano13061089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 03/11/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Owing to the high efficiency and specificity in moderate conditions, enzymatic biofuel cells (EBFCs) have gained significant interest as a promising energy source for wearable devices. However, the instability of the bioelectrode and the lack of efficient electrical communication between the enzymes and electrodes are the main obstacles. Herein, defect-enriched 3D graphene nanoribbons (GNRs) frameworks are fabricated by unzipping multiwall carbon nanotubes, followed by thermal annealing. It is found that defective carbon shows stronger adsorption energy towards the polar mediators than the pristine carbon, which is beneficial to improving the stability of the bioelectrodes. Consequently, the EBFCs equipped with the GNRs exhibit a significantly enhanced bioelectrocatalytic performance and operational stability, delivering an open-circuit voltage and power density of 0.62 V, 70.7 μW/cm2, and 0.58 V, 18.6 μW/cm2 in phosphate buffer solution and artificial tear, respectively, which represent the high levels among the reported literature. This work provides a design principle according to which defective carbon materials could be more suitable for the immobilization of biocatalytic components in the application of EBFCs.
Collapse
Affiliation(s)
- Xiaoyu Feng
- College of Textiles and Clothing, Xinjiang University, Urumqi 830046, China
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Yongyue Ning
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Nanobiosensing and Nanobioanalysis, Universities of Jilin Province, Northeast Normal University, Changchun 130024, China
| | - Zhongdong Wu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Zihan Li
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Nanobiosensing and Nanobioanalysis, Universities of Jilin Province, Northeast Normal University, Changchun 130024, China
| | - Cuixing Xu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Gangyong Li
- Beijing Institute of Radiation Medicine, Beijing 100850, China
- Key Laboratory of Hunan Province for Advanced Carbon-Based Functional Materials, School of Chemistry and Chemical Engineering, Hunan Institute of Science and Technology, Yueyang 414006, China
| | - Zongqian Hu
- Beijing Institute of Radiation Medicine, Beijing 100850, China
| |
Collapse
|
7
|
Environment-Friendly Ascorbic Acid Fuel Cell. ELECTROCHEM 2023. [DOI: 10.3390/electrochem4010003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Recently, ascorbic acid (AA) has been studied as an environment-friendly fuel for energy conversion devices. This review article has deliberated an overview of ascorbic acid electrooxidation and diverse ion exchange types of AA-based fuel cells for the first time. Metal and carbon-based catalysts generated remarkable energy from environment-friendly AA fuel. The possibility of using AA in a direct liquid fuel cell (DLFC) without emitting any hazardous pollutants is discussed. AA fuel cells have been reviewed based on carbon nanomaterials, alloys/bimetallic nanoparticles, and precious and nonprecious metal nanoparticles. Finally, the obstacles and opportunities for using AA-based fuel cells in practical applications have also been incorporated.
Collapse
|
8
|
Zhang W, Zhang J, Fan S, Zhang L, Liu C, Liu J. Oxygen reduction catalyzed by bilirubin oxidase and applications in biosensors and biofuel cells. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Kang D, Lee JI, Maeng B, Lee S, Kwon Y, Kang MS, Park J, Kim J. Safe, Durable, and Sustainable Self-Powered Smart Contact Lenses. ACS NANO 2022; 16:15827-15836. [PMID: 36069332 DOI: 10.1021/acsnano.2c05452] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Smart contact lenses have the potential to serve as noninvasive healthcare devices or virtual displays. However, their implementation is limited by the lack of suitable power sources for microelectronic devices. This Article demonstrates smart contact lenses with fully embedded glucose fuel cells that are safe, flexible, and durable against deformations. These fuel cells produced stable power throughout the day or during intermittent use after storage for weeks. When the lenses were exposed to 0.05 mM glucose solution, a steady-state maximum power density of 4.4 μW/cm2 was achieved by optimizing the chemistry and porous structure of the fuel cell components. Additionally, even after bending the lenses in half 100 times, the fuel cell performance was maintained without any mechanical failure. Lastly, when the fuel cells were connected to electroresponsive hydrogel capacitors, we could clearly distinguish between the tear glucose levels under normal and diabetic conditions through the naked eye.
Collapse
Affiliation(s)
- Dongwon Kang
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Jong Ik Lee
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Bohee Maeng
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Seyeon Lee
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Yongseok Kwon
- School of Pharmacy, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Moon Sung Kang
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
- Institute of Emergent Materials, Sogang University, Seoul 04107, Republic of Korea
| | - Jungyul Park
- Department of Mechanical Engineering, Sogang University, Seoul 04107, Republic of Korea
| | - Jungwook Kim
- Department of Chemical and Biomolecular Engineering, Sogang University, Seoul 04107, Republic of Korea
| |
Collapse
|
10
|
Serag E, El-Maghraby A, El Nemr A. Recent developments in the application of carbon-based nanomaterials in implantable and wearable enzyme-biofuel cells. CARBON LETTERS 2022; 32:395-412. [DOI: 10.1007/s42823-021-00299-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 10/15/2021] [Accepted: 10/20/2021] [Indexed: 01/12/2025]
|
11
|
Mirzajani H, Mirlou F, Istif E, Singh R, Beker L. Powering smart contact lenses for continuous health monitoring: Recent advancements and future challenges. Biosens Bioelectron 2022; 197:113761. [PMID: 34800926 DOI: 10.1016/j.bios.2021.113761] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 10/15/2021] [Accepted: 10/29/2021] [Indexed: 12/16/2022]
Abstract
As the tear is noninvasively and continuously available, it has been turned into a convenient biological interface as a wearable medical device for out-of-hospital and self-monitoring applications. Recent progress in integrated circuits (ICs) and biosensors coupled with wireless data communication techniques have led to the implementation of smart contact lenses that can continuously sample tear fluid, analyze physiological conditions, and wirelessly transmit data to an electronic device such as smartphone, which can send data to relevant healthcare units. Continuous analyte monitoring is one of the significant characteristics of wearable biosensors. However, despite several advantages over other on-skin wearable medical devices, batteries cannot be incorporated on smart contact lenses for continuous electrical power supply due to the limited area. Herein, we review the progress of power delivery techniques of smart contact lenses for the first time. Different approaches, including wireless power transmission (WPT), biofuel cells, supercapacitors, flexible batteries, wired connections, and hybrid methods, are thoroughly discussed to understand the principles of self-sustainable contact lens biosensors comprehensively. Additionally, recent progress in contact lens biosensors is reviewed in detail, thereby providing the prospects for further developments of smart contact lenses as a common biosensing platform for various disease monitoring and diagnostic applications.
Collapse
Affiliation(s)
- Hadi Mirzajani
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Fariborz Mirlou
- Department of Electrical and Electronics Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Emin Istif
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Rahul Singh
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey
| | - Levent Beker
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey; Koç University Research Center for Translational Research (KUTTAM), Rumelifeneri Yolu, Sarıyer, Istanbul, 34450, Turkey.
| |
Collapse
|
12
|
Nakagawa T, Abe H, Gessei T, Takeda K, Igarashi K, Nakamura N. Biorefinery of galacturonic acid using a biofuel cell as a reactor. REACT CHEM ENG 2022. [DOI: 10.1039/d2re00202g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A reactor based on an enzymatic biofuel cell (an EBFC reactor) was constructed to simultaneously generate electricity and chemical products from biomass.
Collapse
Affiliation(s)
- Tomoe Nakagawa
- Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064, Japan
- Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Hayato Abe
- Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| | - Tomoko Gessei
- Tokyo Metropolitan Industrial Technology Research Institute, 2-4-10 Aomi, Koto-ku, Tokyo 135-0064, Japan
| | - Kouta Takeda
- Department of Biomaterials Sciences, Graduate School of Agriculture and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo, Tokyo 113-8657, Japan
| | - Kiyohiko Igarashi
- Department of Biomaterials Sciences, Graduate School of Agriculture and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo, Tokyo 113-8657, Japan
| | - Nobuhumi Nakamura
- Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei, Tokyo 184-8588, Japan
| |
Collapse
|
13
|
Zhang S, Zeng J, Wang C, Feng L, Song Z, Zhao W, Wang Q, Liu C. The Application of Wearable Glucose Sensors in Point-of-Care Testing. Front Bioeng Biotechnol 2021; 9:774210. [PMID: 34957071 PMCID: PMC8692794 DOI: 10.3389/fbioe.2021.774210] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Accepted: 11/18/2021] [Indexed: 12/18/2022] Open
Abstract
Diabetes and its complications have become a worldwide concern that influences human health negatively and even leads to death. The real-time and convenient glucose detection in biofluids is urgently needed. Traditional glucose testing is detecting glucose in blood and is invasive, which cannot be continuous and results in discomfort for the users. Consequently, wearable glucose sensors toward continuous point-of-care glucose testing in biofluids have attracted great attention, and the trend of glucose testing is from invasive to non-invasive. In this review, the wearable point-of-care glucose sensors for the detection of different biofluids including blood, sweat, saliva, tears, and interstitial fluid are discussed, and the future trend of development is prospected.
Collapse
Affiliation(s)
- Sheng Zhang
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| | - Junyan Zeng
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| | - Chunge Wang
- School of Mechanical and Energy Engineering, Ningbo Tech University, Ningbo, China
| | - Luying Feng
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| | - Zening Song
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| | - Wenjie Zhao
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| | - Qianqian Wang
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, China
| | - Chen Liu
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Ningbo Research Institute, Zhejiang University, Hangzhou, China
| |
Collapse
|
14
|
Johnston L, Wang G, Hu K, Qian C, Liu G. Advances in Biosensors for Continuous Glucose Monitoring Towards Wearables. Front Bioeng Biotechnol 2021; 9:733810. [PMID: 34490230 PMCID: PMC8416677 DOI: 10.3389/fbioe.2021.733810] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/09/2021] [Indexed: 11/18/2022] Open
Abstract
Continuous glucose monitors (CGMs) for the non-invasive monitoring of diabetes are constantly being developed and improved. Although there are multiple biosensing platforms for monitoring glucose available on the market, there is still a strong need to enhance their precision, repeatability, wearability, and accessibility to end-users. Biosensing technologies are being increasingly explored that use different bodily fluids such as sweat and tear fluid, etc., that can be calibrated to and therefore used to measure blood glucose concentrations accurately. To improve the wearability of these devices, exploring different fluids as testing mediums is essential and opens the door to various implants and wearables that in turn have the potential to be less inhibiting to the wearer. Recent developments have surfaced in the form of contact lenses or mouthguards for instance. Challenges still present themselves in the form of sensitivity, especially at very high or low glucose concentrations, which is critical for a diabetic person to monitor. This review summarises advances in wearable glucose biosensors over the past 5 years, comparing the different types as well as the fluid they use to detect glucose, including the CGMs currently available on the market. Perspectives on the development of wearables for glucose biosensing are discussed.
Collapse
Affiliation(s)
- Lucy Johnston
- School of Engineering, The University of Glasgow, Glasgow, United Kingdom
| | - Gonglei Wang
- School of Life and Health Sciences, The Chinese University of Hong Kong, Shenzhen, China
| | - Kunhui Hu
- Shenzhen YHLO Biotech Co., Ltd., Shenzhen, China
| | - Chungen Qian
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics, Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, China
| | - Guozhen Liu
- School of Life and Health Sciences, The Chinese University of Hong Kong, Shenzhen, China
| |
Collapse
|
15
|
Bamgboje D, Christoulakis I, Smanis I, Chavan G, Shah R, Malekzadeh M, Violaris I, Giannakeas N, Tsipouras M, Kalafatakis K, Tzallas A. Continuous Non-Invasive Glucose Monitoring via Contact Lenses: Current Approaches and Future Perspectives. BIOSENSORS 2021; 11:189. [PMID: 34207533 PMCID: PMC8226956 DOI: 10.3390/bios11060189] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/23/2021] [Accepted: 06/06/2021] [Indexed: 11/16/2022]
Abstract
Diabetes mellitus (DM) is a chronic disease that must be carefully managed to prevent serious complications such as cardiovascular disease, retinopathy, nephropathy and neuropathy. Self-monitoring of blood glucose is a crucial tool for managing diabetes and, at present, all relevant procedures are invasive while they only provide periodic measurements. The pain and measurement intermittency associated with invasive techniques resulted in the exploration of painless, continuous, and non-invasive techniques of glucose measurement that would facilitate intensive management. The focus of this review paper is the existing solutions for continuous non-invasive glucose monitoring via contact lenses (CLs) and to carry out a detailed, qualitative, and comparative analysis to inform prospective researchers on viable pathways. Direct glucose monitoring via CLs is contingent on the detection of biomarkers present in the lacrimal fluid. In this review, emphasis is given on two types of sensors: a graphene-AgNW hybrid sensor and an amperometric sensor. Both sensors can detect the presence of glucose in the lacrimal fluid by using the enzyme, glucose oxidase. Additionally, this review covers fabrication procedures for CL biosensors. Ever since Google published the first glucose monitoring embedded system on a CL, CL biosensors have been considered state-of-the-art in the medical device research and development industry. The CL not only has to have a sensory system, it must also have an embedded integrated circuit (IC) for readout and wireless communication. Moreover, to retain mobility and ease of use of the CLs used for continuous glucose monitoring, the power supply to the solid-state IC on such CLs must be wireless. Currently, there are four methods of powering CLs: utilizing solar energy, via a biofuel cell, or by inductive or radiofrequency (RF) power. Although, there are many limitations associated with each method, the limitations common to all, are safety restrictions and CL size limitations. Bearing this in mind, RF power has received most of the attention in reported literature, whereas solar power has received the least attention in the literature. CLs seem a very promising target for cutting edge biotechnological applications of diagnostic, prognostic and therapeutic relevance.
Collapse
Affiliation(s)
- David Bamgboje
- Department of Electrical & Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA; (D.B.); (I.S.); (G.C.); (R.S.); (M.M.)
| | - Iasonas Christoulakis
- Department of Informatics and Telecommunications, School of Informatics and Telecommunications, University of Ioannina, 471 00 Arta, Greece; (I.C.); (N.G.); (K.K.)
| | - Ioannis Smanis
- Department of Electrical & Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA; (D.B.); (I.S.); (G.C.); (R.S.); (M.M.)
| | - Gaurav Chavan
- Department of Electrical & Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA; (D.B.); (I.S.); (G.C.); (R.S.); (M.M.)
| | - Rinkal Shah
- Department of Electrical & Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA; (D.B.); (I.S.); (G.C.); (R.S.); (M.M.)
| | - Masoud Malekzadeh
- Department of Electrical & Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA; (D.B.); (I.S.); (G.C.); (R.S.); (M.M.)
| | - Ioannis Violaris
- Department of Electrical and Computer Engineering, University of Western Macedonia, 501 31 Kozani, Greece; (I.V.); (M.T.)
| | - Nikolaos Giannakeas
- Department of Informatics and Telecommunications, School of Informatics and Telecommunications, University of Ioannina, 471 00 Arta, Greece; (I.C.); (N.G.); (K.K.)
| | - Markos Tsipouras
- Department of Electrical and Computer Engineering, University of Western Macedonia, 501 31 Kozani, Greece; (I.V.); (M.T.)
| | - Konstantinos Kalafatakis
- Department of Informatics and Telecommunications, School of Informatics and Telecommunications, University of Ioannina, 471 00 Arta, Greece; (I.C.); (N.G.); (K.K.)
| | - Alexandros Tzallas
- Department of Informatics and Telecommunications, School of Informatics and Telecommunications, University of Ioannina, 471 00 Arta, Greece; (I.C.); (N.G.); (K.K.)
| |
Collapse
|
16
|
Xu J, Li R, Xu H, Yang Y, Zhang S, Ren T. Recent progress of continuous intraocular pressure monitoring. NANO SELECT 2021. [DOI: 10.1002/nano.202100137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Jiandong Xu
- Institute of Microelectronics Tsinghua University Beijing 100084 China
- Beijing National Research Center for Information Science and Technology (BNRist) Tsinghua University Beijing 100084 China
| | - Ruisong Li
- Department of Electrical Engineering and Computer Science and Department of Bioengineering College of Engineering University of California Berkeley California 94720 USA
| | - Haokai Xu
- Institute of Microelectronics Tsinghua University Beijing 100084 China
- Beijing National Research Center for Information Science and Technology (BNRist) Tsinghua University Beijing 100084 China
| | - Yi Yang
- Institute of Microelectronics Tsinghua University Beijing 100084 China
- Beijing National Research Center for Information Science and Technology (BNRist) Tsinghua University Beijing 100084 China
| | - Sheng Zhang
- Shenzhen International Graduate School Tsinghua University Shenzhen 518055 China
| | - Tian‐Ling Ren
- Institute of Microelectronics Tsinghua University Beijing 100084 China
- Beijing National Research Center for Information Science and Technology (BNRist) Tsinghua University Beijing 100084 China
- Center for Flexible Electronics Technology Tsinghua University Beijing 100084 China
| |
Collapse
|
17
|
Geiss A, Reichhart TMB, Pejker B, Plattner E, Herzog PL, Schulz C, Ludwig R, Felice AKG, Haltrich D. Engineering the Turnover Stability of Cellobiose Dehydrogenase toward Long-Term Bioelectronic Applications. ACS SUSTAINABLE CHEMISTRY & ENGINEERING 2021; 9:7086-7100. [PMID: 34306835 PMCID: PMC8296668 DOI: 10.1021/acssuschemeng.1c01165] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 04/16/2021] [Indexed: 05/09/2023]
Abstract
Cellobiose dehydrogenase (CDH) is an attractive oxidoreductase for bioelectrochemical applications. Its two-domain structure allows the flavoheme enzyme to establish direct electron transfer to biosensor and biofuel cell electrodes. Yet, the application of CDH in these devices is impeded by its limited stability under turnover conditions. In this work, we aimed to improve the turnover stability of CDH by semirational, high-throughput enzyme engineering. We screened 13 736 colonies in a 96-well plate setup for improved turnover stability and selected 11 improved variants. Measures were taken to increase the reproducibility and robustness of the screening setup, and the statistical evaluation demonstrates the validity of the procedure. The selected CDH variants were expressed in shaking flasks and characterized in detail by biochemical and electrochemical methods. Two mechanisms contributing to turnover stability were found: (i) replacement of methionine side chains prone to oxidative damage and (ii) the reduction of oxygen reactivity achieved by an improved balance of the individual reaction rates in the two CDH domains. The engineered CDH variants hold promise for the application in continuous biosensors or biofuel cells, while the deduced mechanistic insights serve as a basis for future enzyme engineering approaches addressing the turnover stability of oxidoreductases in general.
Collapse
Affiliation(s)
- Andreas
F. Geiss
- Biocatalysis
and Biosensing Laboratory, Department of Food Science and Technology, BOKU − University of Natural Resources and
Life Sciences, Muthgasse 18, 1190 Vienna, Austria
| | - Thomas M. B. Reichhart
- Biocatalysis
and Biosensing Laboratory, Department of Food Science and Technology, BOKU − University of Natural Resources and
Life Sciences, Muthgasse 18, 1190 Vienna, Austria
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
| | - Barbara Pejker
- Biocatalysis
and Biosensing Laboratory, Department of Food Science and Technology, BOKU − University of Natural Resources and
Life Sciences, Muthgasse 18, 1190 Vienna, Austria
| | - Esther Plattner
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
| | - Peter L. Herzog
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
| | - Christopher Schulz
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
| | - Roland Ludwig
- Biocatalysis
and Biosensing Laboratory, Department of Food Science and Technology, BOKU − University of Natural Resources and
Life Sciences, Muthgasse 18, 1190 Vienna, Austria
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
| | - Alfons K. G. Felice
- DirectSens
Biosensors GmbH, Am Rosenbühel
38, 3400 Klosterneuburg, Austria
- E-mail: . Telephone: +436505000167
| | - Dietmar Haltrich
- Biocatalysis
and Biosensing Laboratory, Department of Food Science and Technology, BOKU − University of Natural Resources and
Life Sciences, Muthgasse 18, 1190 Vienna, Austria
| |
Collapse
|
18
|
Andriukonis E, Celiesiute-Germaniene R, Ramanavicius S, Viter R, Ramanavicius A. From Microorganism-Based Amperometric Biosensors towards Microbial Fuel Cells. SENSORS (BASEL, SWITZERLAND) 2021; 21:2442. [PMID: 33916302 PMCID: PMC8038125 DOI: 10.3390/s21072442] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/25/2021] [Accepted: 03/29/2021] [Indexed: 02/06/2023]
Abstract
This review focuses on the overview of microbial amperometric biosensors and microbial biofuel cells (MFC) and shows how very similar principles are applied for the design of both types of these bioelectronics-based devices. Most microorganism-based amperometric biosensors show poor specificity, but this drawback can be exploited in the design of microbial biofuel cells because this enables them to consume wider range of chemical fuels. The efficiency of the charge transfer is among the most challenging and critical issues during the development of any kind of biofuel cell. In most cases, particular redox mediators and nanomaterials are applied for the facilitation of charge transfer from applied biomaterials towards biofuel cell electrodes. Some improvements in charge transfer efficiency can be achieved by the application of conducting polymers (CPs), which can be used for the immobilization of enzymes and in some particular cases even for the facilitation of charge transfer. In this review, charge transfer pathways and mechanisms, which are suitable for the design of biosensors and in biofuel cells, are discussed. Modification methods of the cell-wall/membrane by conducting polymers in order to enhance charge transfer efficiency of microorganisms, which can be potentially applied in the design of microbial biofuel cells, are outlined. The biocompatibility-related aspects of conducting polymers with microorganisms are summarized.
Collapse
Affiliation(s)
- Eivydas Andriukonis
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Raimonda Celiesiute-Germaniene
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Laboratory of Bioelectrics, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Simonas Ramanavicius
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Roman Viter
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Center for Collective Use of Scientific Equipment, Sumy State University, 40018 Sumy, Ukraine
- Institute of Atomic Physics and Spectroscopy, University of Latvia, LV-1004 Riga, Latvia
| | - Arunas Ramanavicius
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| |
Collapse
|
19
|
Sano J, Takaki Y. Holographic contact lens display that provides focusable images for eyes. OPTICS EXPRESS 2021; 29:10568-10579. [PMID: 33820190 DOI: 10.1364/oe.419604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 03/09/2021] [Indexed: 06/12/2023]
Abstract
In this paper, we propose a holographic image generation technique for contact lens displays. The proposed technique employs a phase-only spatial light modulator (SLM), a holographic optical element (HOE) backlight, and a polarizer. The proposed holographic technique can generate 3D images apart from the contact lens displays. Therefore, the eyes can focus on the 3D images while simultaneously observing the real scene through the phase-only SLM and the HOE backlight, which provides see-through capability. A bench-top experimental system was constructed to verify the far-distance image generation capability and see-through function.
Collapse
|
20
|
Yu S, Myung NV. Recent Advances in the Direct Electron Transfer-Enabled Enzymatic Fuel Cells. Front Chem 2021; 8:620153. [PMID: 33644003 PMCID: PMC7902792 DOI: 10.3389/fchem.2020.620153] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 12/09/2020] [Indexed: 12/16/2022] Open
Abstract
Direct electron transfer (DET), which requires no mediator to shuttle electrons from enzyme active site to the electrode surface, minimizes complexity caused by the mediator and can further enable miniaturization for biocompatible and implantable devices. However, because the redox cofactors are typically deeply embedded in the protein matrix of the enzymes, electrons generated from oxidation reaction cannot easily transfer to the electrode surface. In this review, methods to improve the DET rate for enhancement of enzymatic fuel cell performances are summarized, with a focus on the more recent works (past 10 years). Finally, progress on the application of DET-enabled EFC to some biomedical and implantable devices are reported.
Collapse
Affiliation(s)
| | - Nosang V. Myung
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| |
Collapse
|
21
|
Ramanavicius S, Ramanavicius A. Charge Transfer and Biocompatibility Aspects in Conducting Polymer-Based Enzymatic Biosensors and Biofuel Cells. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:371. [PMID: 33540587 PMCID: PMC7912793 DOI: 10.3390/nano11020371] [Citation(s) in RCA: 74] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/23/2021] [Accepted: 01/24/2021] [Indexed: 02/06/2023]
Abstract
Charge transfer (CT) is a very important issue in the design of biosensors and biofuel cells. Some nanomaterials can be applied to facilitate the CT in these bioelectronics-based devices. In this review, we overview some CT mechanisms and/or pathways that are the most frequently established between redox enzymes and electrodes. Facilitation of indirect CT by the application of some nanomaterials is frequently applied in electrochemical enzymatic biosensors and biofuel cells. More sophisticated and still rather rarely observed is direct charge transfer (DCT), which is often addressed as direct electron transfer (DET), therefore, DCT/DET is also targeted and discussed in this review. The application of conducting polymers (CPs) for the immobilization of enzymes and facilitation of charge transfer during the design of biosensors and biofuel cells are overviewed. Significant attention is paid to various ways of synthesis and application of conducting polymers such as polyaniline, polypyrrole, polythiophene poly(3,4-ethylenedioxythiophene). Some DCT/DET mechanisms in CP-based sensors and biosensors are discussed, taking into account that not only charge transfer via electrons, but also charge transfer via holes can play a crucial role in the design of bioelectronics-based devices. Biocompatibility aspects of CPs, which provides important advantages essential for implantable bioelectronics, are discussed.
Collapse
Affiliation(s)
- Simonas Ramanavicius
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania
| | - Arunas Ramanavicius
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania
| |
Collapse
|
22
|
Sharma A, Badea M, Tiwari S, Marty JL. Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring. Molecules 2021; 26:748. [PMID: 33535493 PMCID: PMC7867046 DOI: 10.3390/molecules26030748] [Citation(s) in RCA: 97] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 01/24/2021] [Accepted: 01/26/2021] [Indexed: 12/18/2022] Open
Abstract
With the increasing prevalence of growing population, aging and chronic diseases continuously rising healthcare costs, the healthcare system is undergoing a vital transformation from the traditional hospital-centered system to an individual-centered system. Since the 20th century, wearable sensors are becoming widespread in healthcare and biomedical monitoring systems, empowering continuous measurement of critical biomarkers for monitoring of the diseased condition and health, medical diagnostics and evaluation in biological fluids like saliva, blood, and sweat. Over the past few decades, the developments have been focused on electrochemical and optical biosensors, along with advances with the non-invasive monitoring of biomarkers, bacteria and hormones, etc. Wearable devices have evolved gradually with a mix of multiplexed biosensing, microfluidic sampling and transport systems integrated with flexible materials and body attachments for improved wearability and simplicity. These wearables hold promise and are capable of a higher understanding of the correlations between analyte concentrations within the blood or non-invasive biofluids and feedback to the patient, which is significantly important in timely diagnosis, treatment, and control of medical conditions. However, cohort validation studies and performance evaluation of wearable biosensors are needed to underpin their clinical acceptance. In the present review, we discuss the importance, features, types of wearables, challenges and applications of wearable devices for biological fluids for the prevention of diseased conditions and real-time monitoring of human health. Herein, we summarize the various wearable devices that are developed for healthcare monitoring and their future potential has been discussed in detail.
Collapse
Affiliation(s)
- Atul Sharma
- School of Chemistry, Monash University, Clayton, Melbourne, VIC 3800, Australia
- Department of Pharmaceutical Chemistry, SGT College of Pharmacy, SGT University, Budhera, Gurugram, Haryana 122505, India
| | - Mihaela Badea
- Fundamental, Prophylactic and Clinical Specialties Department, Faculty of Medicine, Transilvania University of Brasov, 500036 Brasov, Romania;
| | - Swapnil Tiwari
- School of Studies in Chemistry, Pt Ravishankar Shukla University, Raipur, CHATTISGARH 492010, India;
| | - Jean Louis Marty
- University of Perpignan via Domitia, 52 Avenue Paul Alduy, CEDEX 9, 66860 Perpignan, France
| |
Collapse
|
23
|
WANIBUCHI M, KITAZUMI Y, SHIRAI O, KANO K. Enhancement of the Direct Electron Transfer-type Bioelectrocatalysis of Bilirubin Oxidase at the Interface between Carbon Particles. ELECTROCHEMISTRY 2021. [DOI: 10.5796/electrochemistry.20-00128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Affiliation(s)
- Mizue WANIBUCHI
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University
| | - Yuki KITAZUMI
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University
| | - Osamu SHIRAI
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University
| | - Kenji KANO
- Division of Applied Life Sciences, Graduate School of Agriculture, Kyoto University
| |
Collapse
|
24
|
Buaki-Sogó M, García-Carmona L, Gil-Agustí M, Zubizarreta L, García-Pellicer M, Quijano-López A. Enzymatic Glucose-Based Bio-batteries: Bioenergy to Fuel Next-Generation Devices. Top Curr Chem (Cham) 2020; 378:49. [PMID: 33125588 DOI: 10.1007/s41061-020-00312-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 10/05/2020] [Indexed: 11/26/2022]
Abstract
This article consists of a review of the main concepts and paradigms established in the field of biological fuel cells or biofuel cells. The aim is to provide an overview of the current panorama, basic concepts, and methodologies used in the field of enzymatic biofuel cells, as well as the applications of these bio-systems in flexible electronics and implantable or portable devices. Finally, the challenges needing to be addressed in the development of biofuel cells capable of supplying power to small size devices with applications in areas related to health and well-being or next-generation portable devices are analyzed. The aim of this study is to contribute to biofuel cell technology development; this is a multidisciplinary topic about which review articles related to different scientific areas, from Materials Science to technology applications, can be found. With this article, the authors intend to reach a wide readership in order to spread biofuel cell technology for different scientific profiles and boost new contributions and developments to overcome future challenges.
Collapse
Affiliation(s)
- Mireia Buaki-Sogó
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain.
| | - Laura García-Carmona
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Mayte Gil-Agustí
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Leire Zubizarreta
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Marta García-Pellicer
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Alfredo Quijano-López
- ITE Universitat Politécnica de València, Camino de Vera s/n edificio 6C, 46022, Valencia, Spain
| |
Collapse
|
25
|
Jin X, Liu C, Xu T, Su L, Zhang X. Artificial intelligence biosensors: Challenges and prospects. Biosens Bioelectron 2020; 165:112412. [DOI: 10.1016/j.bios.2020.112412] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/24/2020] [Accepted: 06/25/2020] [Indexed: 12/13/2022]
|
26
|
Flexible and optimized carbon paste electrodes for direct electron transfer-based glucose biofuel cell fed by various physiological fluids. APPLIED NANOSCIENCE 2020. [DOI: 10.1007/s13204-020-01543-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
27
|
Bocchetta P, Frattini D, Ghosh S, Mohan AMV, Kumar Y, Kwon Y. Soft Materials for Wearable/Flexible Electrochemical Energy Conversion, Storage, and Biosensor Devices. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E2733. [PMID: 32560176 PMCID: PMC7345738 DOI: 10.3390/ma13122733] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 06/08/2020] [Accepted: 06/12/2020] [Indexed: 02/07/2023]
Abstract
Next-generation wearable technology needs portable flexible energy storage, conversion, and biosensor devices that can be worn on soft and curved surfaces. The conformal integration of these devices requires the use of soft, flexible, light materials, and substrates with similar mechanical properties as well as high performances. In this review, we have collected and discussed the remarkable research contributions of recent years, focusing the attention on the development and arrangement of soft and flexible materials (electrodes, electrolytes, substrates) that allowed traditional power sources and sensors to become viable and compatible with wearable electronics, preserving or improving their conventional performances.
Collapse
Affiliation(s)
- Patrizia Bocchetta
- Dipartimento di Ingegneria dell’Innovazione, Università del Salento, via Monteroni, 73100 Lecce, Italy
| | - Domenico Frattini
- Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea;
| | - Srabanti Ghosh
- Department of Organic and Inorganic Chemistry, Universidad de Alcala (UAH), Alcalá de Henares, 28805 Madrid, Spain;
| | - Allibai Mohanan Vinu Mohan
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India;
| | - Yogesh Kumar
- Department of Physics, ARSD College, University of Delhi, Delhi 110021, India;
| | - Yongchai Kwon
- Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea;
- Department of Chemical and Biomolecular Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
| |
Collapse
|
28
|
Yu Y, Nassar J, Xu C, Min J, Yang Y, Dai A, Doshi R, Huang A, Song Y, Gehlhar R, Ames AD, Gao W. Biofuel-powered soft electronic skin with multiplexed and wireless sensing for human-machine interfaces. Sci Robot 2020; 5:eaaz7946. [PMID: 32607455 PMCID: PMC7326328 DOI: 10.1126/scirobotics.aaz7946] [Citation(s) in RCA: 255] [Impact Index Per Article: 51.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Existing electronic skin (e-skin) sensing platforms are equipped to monitor physical parameters using power from batteries or near-field communication. For e-skins to be applied in the next generation of robotics and medical devices, they must operate wirelessly and be self-powered. However, despite recent efforts to harvest energy from the human body, self-powered e-skin with the ability to perform biosensing with Bluetooth communication are limited because of lack of a continuous energy source and limited power efficiency. Here, we report a flexible and fully perspiration-powered integrated electronic skin (PPES) for multiplexed metabolic sensing in situ. The battery-free e-skin contains multimodal sensors and highly efficient lactate biofuel cells that use a unique integration of zero- to three-dimensional nanomaterials to achieve high power intensity and long-term stability. The PPES delivered a record-breaking power density of 3.5 milliwatt-centimeter-2 for biofuel cells in untreated human body fluids (human sweat) and displayed a very stable performance during a 60-hour continuous operation. It selectively monitored key metabolic analytes (e.g., urea, NH4 +, glucose, and pH) and the skin temperature during prolonged physical activities and wirelessly transmitted the data to the user interface using Bluetooth. The PPES was also able to monitor muscle contraction and work as a human-machine interface for human- prosthesis walking.
Collapse
Affiliation(s)
- You Yu
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Joanna Nassar
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Changhao Xu
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Jihong Min
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yiran Yang
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Adam Dai
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Rohan Doshi
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Adrian Huang
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Yu Song
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Rachel Gehlhar
- Department of Mechanical and Civil Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Aaron D. Ames
- Department of Mechanical and Civil Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
| |
Collapse
|
29
|
Bollella P. Porous Gold: A New Frontier for Enzyme-Based Electrodes. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E722. [PMID: 32290306 PMCID: PMC7221854 DOI: 10.3390/nano10040722] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 04/01/2020] [Accepted: 04/08/2020] [Indexed: 12/23/2022]
Abstract
Porous gold (PG) layers modified electrodes have emerged as valuable enzyme support to realize multiple enzyme-based bioelectrochemical devices like biosensors, enzymatic fuel cells (EFCs), smart drug delivery devices triggered by enzyme catalyzed reactions, etc. PG films can be synthesized by using different methods such as dealloying, electrochemical (e.g., templated electrochemical deposition, self-templated electrochemical deposition, etc.) self-assembly and sputter deposition. This review aims to summarize the recent findings about PG synthesis and electrosynthesis, its characterization and application for enzyme-based electrodes used for biosensors and enzymatic fuel cells (EFCs) development.
Collapse
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, 13699-5810 NY, USA
| |
Collapse
|
30
|
Tang H, Alqattan B, Jackson T, Pikramenou Z, Sun XW, Wang K, Butt H. Cost-Efficient Printing of Graphene Nanostructures on Smart Contact Lenses. ACS APPLIED MATERIALS & INTERFACES 2020; 12:10820-10828. [PMID: 32039575 DOI: 10.1021/acsami.9b21300] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Smart contact lenses have been put forward for years, but there is still no commercial product in the market; the high cost due to expensive fabrication techniques could be one of the reasons. In this paper, first, a cost-efficient and reliable route to fabricate graphene grating on contact lens was designed and demonstrated based on the direct laser interference patterning graphene film on commercial contact lenses using an Nd:YAG laser. The thickness of the film and the interference angle have been taken into consideration. Optical characterization and simulation have been applied to evaluate the quality of our final achieved grating patterns with a grating size from 0.92 to 3.04 μm. Two-dimensional (2D) patterns could also be obtained through double-time laser interference. Contact angles for samples with different interference angles were presented considering the service environment of smart contact lenses. Of course, the conductivity of the samples was evaluated using a four-probe method. The most conductive sample had the sheet resistance lower than 30 Ω/sq. This research study highlighted the possibility of patterning graphene with the laser ablation method and provided a candidate solution for the fabrication of smart contact lenses under controlled cost.
Collapse
Affiliation(s)
- Haodong Tang
- Department of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, U.K
- Shenzhen Key Laboratory for Advanced Quantum Dot Displays and Lighting, Southern University of Science and Technology, Shenzhen 518055, China
| | - Bader Alqattan
- Department of Mechanical Engineering, University of Birmingham, Birmingham B15 2TT, U.K
| | - Tim Jackson
- Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Birmingham B15 2TT, U.K
| | - Zoe Pikramenou
- Department of Chemistry, University of Birmingham, Birmingham B15 2TT, U.K
| | - Xiao Wei Sun
- Shenzhen Key Laboratory for Advanced Quantum Dot Displays and Lighting, Southern University of Science and Technology, Shenzhen 518055, China
| | - Kai Wang
- Shenzhen Key Laboratory for Advanced Quantum Dot Displays and Lighting, Southern University of Science and Technology, Shenzhen 518055, China
| | - Haider Butt
- Department of Mechanical Engineering, Khalifa University of Science and Technology, P.O. Box 127788, Abu Dhabi, United Arab Emirates
| |
Collapse
|
31
|
Caneppele GL, Reis DD, Goncalves AB, Da Silva GC, Martins CA. Active Porous Electrodes Prepared by Ultrasonic‐bath and their Application in Glucose/O
2
Electrochemical Reactions. ELECTROANAL 2020. [DOI: 10.1002/elan.201900625] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Gabriella L. Caneppele
- Institute of Physics Universidade Federal de Mato Grosso do Sul, CP 549 79070-900 Campo Grande, MS Brazil
| | - Diogo D. Reis
- Institute of Physics Universidade Federal de Mato Grosso do Sul, CP 549 79070-900 Campo Grande, MS Brazil
| | - Alem‐Mar B. Goncalves
- Institute of Physics Universidade Federal de Mato Grosso do Sul, CP 549 79070-900 Campo Grande, MS Brazil
| | - Gabriel C. Da Silva
- Instituto de Química de São Carlos Universidade de São Paulo, IQSC-USP C.P. 780 São Carlos, SP Brazil
| | - Cauê A. Martins
- Institute of Physics Universidade Federal de Mato Grosso do Sul, CP 549 79070-900 Campo Grande, MS Brazil
| |
Collapse
|
32
|
Bollella P, Lee I, Blaauw D, Katz E. A Microelectronic Sensor Device Powered by a Small Implantable Biofuel Cell. Chemphyschem 2019; 21:120-128. [DOI: 10.1002/cphc.201900700] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 08/12/2019] [Indexed: 12/15/2022]
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Biomolecular ScienceClarkson University Potsdam NY 13699–5810 USA
| | - Inhee Lee
- Department of Electrical Engineering and Computer ScienceUniversity of Michigan Ann Arbor MI 48109 USA
| | - David Blaauw
- Department of Electrical Engineering and Computer ScienceUniversity of Michigan Ann Arbor MI 48109 USA
| | - Evgeny Katz
- Department of Chemistry and Biomolecular ScienceClarkson University Potsdam NY 13699–5810 USA
| |
Collapse
|
33
|
Yin S, Jin Z, Miyake T. Wearable high-powered biofuel cells using enzyme/carbon nanotube composite fibers on textile cloth. Biosens Bioelectron 2019; 141:111471. [DOI: 10.1016/j.bios.2019.111471] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 06/18/2019] [Accepted: 06/22/2019] [Indexed: 10/26/2022]
|
34
|
Scheiblbrandner S, Ludwig R. Cellobiose dehydrogenase: Bioelectrochemical insights and applications. Bioelectrochemistry 2019; 131:107345. [PMID: 31494387 DOI: 10.1016/j.bioelechem.2019.107345] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 08/01/2019] [Accepted: 08/01/2019] [Indexed: 12/17/2022]
Abstract
Cellobiose dehydrogenase (CDH) is a flavocytochrome with a history of bioelectrochemical research dating back to 1992. During the years, it has been shown to be capable of mediated electron transfer (MET) and direct electron transfer (DET) to a variety of electrodes. This versatility of CDH originates from the separation of the catalytic flavodehydrogenase domain and the electron transferring cytochrome domain. This uncoupling of the catalytic reaction from the electron transfer process allows the application of CDH on many different electrode materials and surfaces, where it shows robust DET. Recent X-ray diffraction and small angle scattering studies provided insights into the structure of CDH and its domain mobility, which can change between a closed-state and an open-state conformation. This structural information verifies the electron transfer mechanism of CDH that was initially established by bioelectrochemical methods. A combination of DET and MET experiments has been used to investigate the catalytic mechanism and the electron transfer process of CDH and to deduce a protein structure comprising of mobile domains. Even more, electrochemical methods have been used to study the redox potentials of the FAD and the haem b cofactors of CDH or the electron transfer rates. These electrochemical experiments, their results and the application of the characterised CDHs in biosensors, biofuel cells and biosupercapacitors are combined with biochemical and structural data to provide a thorough overview on CDH as versatile bioelectrocatalyst.
Collapse
Affiliation(s)
- Stefan Scheiblbrandner
- Biocatalysis and Biosensing Laboratory, Department of Food Science and Technology, BOKU - University of Natural Resources and Life Sciences, Vienna, Muthgasse 11, 1190 Vienna, Austria.
| | - Roland Ludwig
- Biocatalysis and Biosensing Laboratory, Department of Food Science and Technology, BOKU - University of Natural Resources and Life Sciences, Vienna, Muthgasse 11, 1190 Vienna, Austria.
| |
Collapse
|
35
|
Xiao X, Xia HQ, Wu R, Bai L, Yan L, Magner E, Cosnier S, Lojou E, Zhu Z, Liu A. Tackling the Challenges of Enzymatic (Bio)Fuel Cells. Chem Rev 2019; 119:9509-9558. [PMID: 31243999 DOI: 10.1021/acs.chemrev.9b00115] [Citation(s) in RCA: 185] [Impact Index Per Article: 30.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The ever-increasing demands for clean and sustainable energy sources combined with rapid advances in biointegrated portable or implantable electronic devices have stimulated intensive research activities in enzymatic (bio)fuel cells (EFCs). The use of renewable biocatalysts, the utilization of abundant green, safe, and high energy density fuels, together with the capability of working at modest and biocompatible conditions make EFCs promising as next generation alternative power sources. However, the main challenges (low energy density, relatively low power density, poor operational stability, and limited voltage output) hinder future applications of EFCs. This review aims at exploring the underlying mechanism of EFCs and providing possible practical strategies, methodologies and insights to tackle these issues. First, this review summarizes approaches in achieving high energy densities in EFCs, particularly, employing enzyme cascades for the deep/complete oxidation of fuels. Second, strategies for increasing power densities in EFCs, including increasing enzyme activities, facilitating electron transfers, employing nanomaterials, and designing more efficient enzyme-electrode interfaces, are described. The potential of EFCs/(super)capacitor combination is discussed. Third, the review evaluates a range of strategies for improving the stability of EFCs, including the use of different enzyme immobilization approaches, tuning enzyme properties, designing protective matrixes, and using microbial surface displaying enzymes. Fourth, approaches for the improvement of the cell voltage of EFCs are highlighted. Finally, future developments and a prospective on EFCs are envisioned.
Collapse
Affiliation(s)
- Xinxin Xiao
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Hong-Qi Xia
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Ranran Wu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Lu Bai
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Lu Yan
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Serge Cosnier
- Université Grenoble-Alpes , DCM UMR 5250, F-38000 Grenoble , France.,Département de Chimie Moléculaire , UMR CNRS, DCM UMR 5250, F-38000 Grenoble , France
| | - Elisabeth Lojou
- Aix Marseille Univ, CNRS, BIP, Bioénergétique et Ingénierie des Protéines UMR7281 , Institut de Microbiologie de la Méditerranée, IMM , FR 3479, 31, chemin Joseph Aiguier 13402 Marseille , Cedex 20 , France
| | - Zhiguang Zhu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Aihua Liu
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,College of Chemistry & Chemical Engineering , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,School of Pharmacy, Medical College , Qingdao University , Qingdao 266021 , China
| |
Collapse
|
36
|
Lo Dico G, Wicklein B, Lisuzzo L, Lazzara G, Aranda P, Ruiz-Hitzky E. Multicomponent bionanocomposites based on clay nanoarchitectures for electrochemical devices. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2019; 10:1303-1315. [PMID: 31293867 PMCID: PMC6604714 DOI: 10.3762/bjnano.10.129] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 06/05/2019] [Indexed: 05/20/2023]
Abstract
Based on the unique ability of defibrillated sepiolite (SEP) to form stable and homogeneous colloidal dispersions of diverse types of nanoparticles in aqueous media under ultrasonication, multicomponent conductive nanoarchitectured materials integrating halloysite nanotubes (HNTs), graphene nanoplatelets (GNPs) and chitosan (CHI) have been developed. The resulting nanohybrid suspensions could be easily formed into films or foams, where each individual component plays a critical role in the biocomposite: HNTs act as nanocontainers for bioactive species, GNPs provide electrical conductivity (enhanced by doping with MWCNTs) and, the CHI polymer matrix introduces mechanical and membrane properties that are of key significance for the development of electrochemical devices. The resulting characteristics allow for a possible application of these active elements as integrated multicomponent materials for advanced electrochemical devices such as biosensors and enzymatic biofuel cells. This strategy can be regarded as an "a la carte" menu, where the selection of the nanocomponents exhibiting different properties will determine a functional set of predetermined utility with SEP maintaining stable colloidal dispersions of different nanoparticles and polymers in water.
Collapse
Affiliation(s)
- Giulia Lo Dico
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
- Dipartimento di Fisica e Chimica, Università degli Studi di Palermo, Viale delle Scienze pad 17, 90128 Palermo, Italy
| | - Bernd Wicklein
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| | - Lorenzo Lisuzzo
- Dipartimento di Fisica e Chimica, Università degli Studi di Palermo, Viale delle Scienze pad 17, 90128 Palermo, Italy
| | - Giuseppe Lazzara
- Dipartimento di Fisica e Chimica, Università degli Studi di Palermo, Viale delle Scienze pad 17, 90128 Palermo, Italy
| | - Pilar Aranda
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| | - Eduardo Ruiz-Hitzky
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), c/Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| |
Collapse
|
37
|
Krzyczmonik P, Skrzypek S. Composites of Poly (3,4-Ethylenedioxythiophene) with Nanostructures as Electrochemical Sensors for Application in Bioelectroanalysis. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411014666180423150941] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Background:
The article presents the state of research on conductive composite materials
constructed on the basis of poly (3,4-ethylenedioxythiophene) (PEDOT), a conductive polymer, as
well as selected nanoparticles and nanostructures. Combining two or more materials in a composite
which is later used in electrode modification can result in obtaining an electrode with new, more desirable
properties. One of such fields is pharmacological analysis which, due to the continuous emergence
of new substances and often also a need for analyte determination in complex samples, requires
newer instruments in the form of suitably sensitive and selective sensors.
Contents:
The review contains the description of properties of PEDOT and composite PEDOT with
polystyrenesulfonates. In the following part, composite materials are described: PEDOT-CNT, PEDOT-
nanoparticles, PEDOT-graphene. The review closes with the examples of multi-component
composite materials.
Conclusion:
The on-going development of new substances used in medicine, pharmacy and related
fields, as well as the continuous increase in the production and consumption of this type of substances,
necessitates constant development and modernization of analytical techniques used for their determination.
:
Biomedical assays require being able to carry out determinations in different systems, including in
vitro ones, without separating individual compounds. It is necessary to be able to identify several substances
simultaneously or determine one compound in the presence of chemically similar substances.
Modern electrode materials such as PEDOT and nanostructured materials allow for the development
of sensors which are getting increasingly better at meeting the requirements of the analysts.
Collapse
Affiliation(s)
- Paweł Krzyczmonik
- Department of Inorganic and Analytical Chemistry, University of Lodz ul. Tamka 12, 91-403 Lodz, Poland
| | - Sławomira Skrzypek
- Department of Inorganic and Analytical Chemistry, University of Lodz ul. Tamka 12, 91-403 Lodz, Poland
| |
Collapse
|
38
|
Challenges for successful implantation of biofuel cells. Bioelectrochemistry 2018; 124:57-72. [DOI: 10.1016/j.bioelechem.2018.05.011] [Citation(s) in RCA: 121] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 05/11/2018] [Accepted: 05/25/2018] [Indexed: 01/09/2023]
|
39
|
Including Liquid Metal into Porous Elastomeric Films for Flexible and Enzyme-Free Glucose Fuel Cells: A Preliminary Evaluation. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS 2018. [DOI: 10.3390/jlpea8040045] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This communication introduces a new flexible elastomeric composite film, which can directly convert the chemical energy of glucose into electricity. The fabrication process is simple, and no specific equipment is required. Notably, the liquid metal Galinstan is exploited with a two-fold objective: (i) Galinstan particles are mixed with polydimethylsiloxane to obtain a highly conductive porous thick film scaffold; (ii) the presence of Galinstan in the composite film enables the direct growth of highly catalytic gold structures. As a first proof of concept, we demonstrate that when immersed in a 20 mM glucose solution, a 5 mm-long, 5 mm-wide and 2 mm-thick sample can generate a volumetric power density up to 3.6 mW·cm − 3 at 7 mA·cm − 3 and 0.51 V without using any enzymes.
Collapse
|
40
|
Wearable biofuel cells based on the classification of enzyme for high power outputs and lifetimes. Biosens Bioelectron 2018; 124-125:40-52. [PMID: 30343155 DOI: 10.1016/j.bios.2018.09.086] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 09/26/2018] [Accepted: 09/26/2018] [Indexed: 01/06/2023]
Abstract
Wearable enzymatic biofuel cells would be the most prospective fuel cells for wearable devices because of their low cost, compactness and flexibility. As the high specificity and catalytic properties of enzymes, enzymatic biofuel cells (EBFCs) catalyze the fuel associated with the redox reaction and get electrical energy. Available biofuels such as glucose, lactate and pyruvate can be harvested from biofluids of sweat, tears and blood, which afford cells a favorable use in implantable and wearable devices. However, the development of wearable enzymatic biofuel cells requires significant improvements on the power density and enzymes lifetime. In this paper, some new advances in improving the performance of wearable enzymatic biofuel cells are reviewed based on the bioanode and biocathode by classifying single-enzyme and multi-enzyme catalysis system. Thereinto, the bioanode usually contains oxidases and dehydrogenases as catalyst, and the biocathode utilizes the catalysis of multi-copper oxidases (MCOs) in the single system. For further enhancing the power density, efforts to develop multi-enzyme catalysis strategies are discussed in bioanode and biocathode respectively. Moreover, some potential technologies in recent years, such as carbon nanodots, CNT sponges and mixed operational/storage electrode are summarized owing to notable efficiency and the capability of enhancing electron transfer on the electrode. Finally, major challenges and future prospects are discussed for the high power output, stable and practical wearable enzymatic biofuel cells.
Collapse
|
41
|
Fu L, Liu J, Hu Z, Zhou M. Recent Advances in the Construction of Biofuel Cells Based Self-powered Electrochemical Biosensors: A Review. ELECTROANAL 2018. [DOI: 10.1002/elan.201800487] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Liangying Fu
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Key Laboratory of Polyoxometalate Science of Ministry of Education; National & Local United Engineering Laboratory for Power Batteries, Department of Chemistry, Northeast Normal University; Changchun, Jilin Province 130024 P.R. China
| | - Jingju Liu
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Key Laboratory of Polyoxometalate Science of Ministry of Education; National & Local United Engineering Laboratory for Power Batteries, Department of Chemistry, Northeast Normal University; Changchun, Jilin Province 130024 P.R. China
| | - Zongqian Hu
- Beijing Institute of Radiation Medicine; Beijing 100850 P.R. China
| | - Ming Zhou
- Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Key Laboratory of Polyoxometalate Science of Ministry of Education; National & Local United Engineering Laboratory for Power Batteries, Department of Chemistry, Northeast Normal University; Changchun, Jilin Province 130024 P.R. China
| |
Collapse
|
42
|
Bahmanzadeh S, Ruzgas T, Sotres J. Proteolytic degradation of gelatin-tannic acid multilayers. J Colloid Interface Sci 2018; 526:244-252. [DOI: 10.1016/j.jcis.2018.04.112] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 04/26/2018] [Accepted: 04/30/2018] [Indexed: 10/17/2022]
|
43
|
Tseng RC, Chen CC, Hsu SM, Chuang HS. Contact-Lens Biosensors. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2651. [PMID: 30104496 PMCID: PMC6111605 DOI: 10.3390/s18082651] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/06/2018] [Accepted: 08/10/2018] [Indexed: 12/14/2022]
Abstract
Rapid diagnosis and screening of diseases have become increasingly important in predictive and preventive medicine as they improve patient treatment strategies and reduce cost as well as burden on our healthcare system. In this regard, wearable devices are emerging as effective and reliable point-of-care diagnostics that can allow users to monitor their health at home. These wrist-worn, head-mounted, smart-textile, or smart-patches devices can offer valuable information on the conditions of patients as a non-invasive form of monitoring. However, they are significantly limited in monitoring physiological signals and biomechanics, and, mostly, rely on the physical attributes. Recently, developed wearable devices utilize body fluids, such as sweat, saliva, or skin interstitial fluid, and electrochemical interactions to allow continuous physiological condition and disease monitoring for users. Among them, tear fluid has been widely utilized in the investigation of ocular diseases, diabetes, and even cancers, because of its easy accessibility, lower complexity, and minimal invasiveness. By determining the concentration change of analytes within the tear fluid, it would be possible to identify disease progression and allow patient-oriented therapies. Considering the emerging trend of tear-based biosensing technology, this review article aims to focus on an overview of the tear fluid as a detection medium for certain diseases, such as ocular disorders, diabetes, and cancer. In addition, the rise and application of minimally invasive detection and monitoring via integrated contact lens biosensors will also be addressed, in regards to their practicality and current developmental progress.
Collapse
Affiliation(s)
- Ryan Chang Tseng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Ching-Chuen Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Sheng-Min Hsu
- Department of Ophthalmology, National Cheng Kung University Hospital, Tainan City 704, Taiwan.
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
- Medical Device Innovation Center, National Cheng Kung University, Tainan City 701, Taiwan.
| |
Collapse
|
44
|
Bollella P, Gorton L, Antiochia R. Direct Electron Transfer of Dehydrogenases for Development of 3rd Generation Biosensors and Enzymatic Fuel Cells. SENSORS (BASEL, SWITZERLAND) 2018; 18:E1319. [PMID: 29695133 PMCID: PMC5982196 DOI: 10.3390/s18051319] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 04/16/2018] [Accepted: 04/19/2018] [Indexed: 01/04/2023]
Abstract
Dehydrogenase based bioelectrocatalysis has been increasingly exploited in recent years in order to develop new bioelectrochemical devices, such as biosensors and biofuel cells, with improved performances. In some cases, dehydrogeases are able to directly exchange electrons with an appropriately designed electrode surface, without the need for an added redox mediator, allowing bioelectrocatalysis based on a direct electron transfer process. In this review we briefly describe the electron transfer mechanism of dehydrogenase enzymes and some of the characteristics required for bioelectrocatalysis reactions via a direct electron transfer mechanism. Special attention is given to cellobiose dehydrogenase and fructose dehydrogenase, which showed efficient direct electron transfer reactions. An overview of the most recent biosensors and biofuel cells based on the two dehydrogenases will be presented. The various strategies to prepare modified electrodes in order to improve the electron transfer properties of the device will be carefully investigated and all analytical parameters will be presented, discussed and compared.
Collapse
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Drug Technologies, Sapienza University of Rome P.le Aldo Moro 5, 00185 Rome, Italy.
| | - Lo Gorton
- Department of Biochemistry and Structural Biology, Lund University, P.O. Box 124, 221 00 Lund, Sweden.
| | - Riccarda Antiochia
- Department of Chemistry and Drug Technologies, Sapienza University of Rome P.le Aldo Moro 5, 00185 Rome, Italy.
| |
Collapse
|
45
|
Xiao X, Siepenkoetter T, Conghaile PÓ, Leech D, Magner E. Nanoporous Gold-Based Biofuel Cells on Contact Lenses. ACS APPLIED MATERIALS & INTERFACES 2018; 10:7107-7116. [PMID: 29406691 DOI: 10.1021/acsami.7b18708] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A lactate/O2 enzymatic biofuel cell (EBFC) was prepared as a potential power source for wearable microelectronic devices. Mechanically stable and flexible nanoporous gold (NPG) electrodes were prepared using an electrochemical dealloying method consisting of a pre-anodization process and a subsequent electrochemical cleaning step. Bioanodes were prepared by the electrodeposition of an Os polymer and Pediococcus sp. lactate oxidase onto the NPG electrode. The electrocatalytic response to lactate could be tuned by adjusting the deposition time. Bilirubin oxidase from Myrothecium verrucaria was covalently attached to a diazonium-modified NPG surface. A flexible EBFC was prepared by placing the electrodes between two commercially available contact lenses to avoid direct contact with the eye. When tested in air-equilibrated artificial tear solutions (3 mM lactate), a maximum power density of 1.7 ± 0.1 μW cm-2 and an open-circuit voltage of 380 ± 28 mV were obtained, values slightly lower than those obtained in phosphate buffer solution (2.4 ± 0.2 μW cm-2 and 455 ± 21 mV, respectively). The decrease was mainly attributed to interference from ascorbate. After 5.5 h of operation, the EBFC retained 20% of the initial power output.
Collapse
Affiliation(s)
- Xinxin Xiao
- Department of Chemical Sciences and Bernal Institute, University of Limerick , Limerick V94 T9PX, Ireland
| | - Till Siepenkoetter
- Department of Chemical Sciences and Bernal Institute, University of Limerick , Limerick V94 T9PX, Ireland
| | - Peter Ó Conghaile
- School of Chemistry & Ryan Institute, National University of Ireland Galway , Galway H91 TK33, Ireland
| | - Dónal Leech
- School of Chemistry & Ryan Institute, National University of Ireland Galway , Galway H91 TK33, Ireland
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick , Limerick V94 T9PX, Ireland
| |
Collapse
|
46
|
Comprehensive Analysis of Trends and Emerging Technologies in All Types of Fuel Cells Based on a Computational Method. SUSTAINABILITY 2018. [DOI: 10.3390/su10020458] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
47
|
Gonzalez-Solino C, Lorenzo MD. Enzymatic Fuel Cells: Towards Self-Powered Implantable and Wearable Diagnostics. BIOSENSORS 2018; 8:E11. [PMID: 29382147 PMCID: PMC5872059 DOI: 10.3390/bios8010011] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Revised: 01/17/2018] [Accepted: 01/22/2018] [Indexed: 12/18/2022]
Abstract
With the rapid progress in nanotechnology and microengineering, point-of-care and personalised healthcare, based on wearable and implantable diagnostics, is becoming a reality. Enzymatic fuel cells (EFCs) hold great potential as a sustainable means to power such devices by using physiological fluids as the fuel. This review summarises the fundamental operation of EFCs and discusses the most recent advances for their use as implantable and wearable self-powered sensors.
Collapse
Affiliation(s)
| | - Mirella Di Lorenzo
- Department of Chemical Engineering, University of Bath, Bath BA2 7AY, UK.
| |
Collapse
|
48
|
|
49
|
Kai H, Yamauchi T, Ogawa Y, Tsubota A, Magome T, Miyake T, Yamasaki K, Nishizawa M. Accelerated Wound Healing on Skin by Electrical Stimulation with a Bioelectric Plaster. Adv Healthc Mater 2017; 6. [PMID: 28929631 DOI: 10.1002/adhm.201700465] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/25/2017] [Indexed: 12/31/2022]
Abstract
Wound healing on skin involves cell migration and proliferation in response to endogenous electric current. External electrical stimulation by electrical equipment is used to promote these biological processes for the treatment of chronic wounds and ulcers. Miniaturization of the electrical stimulation device for wound healing on skin will make this technology more widely available. Using flexible enzymatic electrodes and stretchable hydrogel, a stretchable bioelectric plaster is fabricated with a built-in enzymatic biofuel cell (EBFC) that fits to skin and generates ionic current along the surface of the skin by enzymatic electrochemical reactions for more than 12 h. To investigate the efficacy of the fabricated bioelectric plaster, an artificial wound is made on the back skin of a live mouse and the wound healing is observed for 7 d in the presence and absence of the ionic current of the bioelectric plaster. The time course of the wound size as well as the hematoxylin and eosin staining of the skin section reveals that the ionic current of the plaster leads to faster and smoother wound healing. The present work demonstrates a proof of concept for the electrical manipulation of biological functions by EBFCs.
Collapse
Affiliation(s)
- Hiroyuki Kai
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| | - Takeshi Yamauchi
- Department of Dermatology; Graduate School of Medicine; Tohoku University; 1-1 Seiryo-machi Aoba-ku, Sendai 980-8574 Japan
| | - Yudai Ogawa
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| | - Ayaka Tsubota
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| | - Takahiro Magome
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| | - Takeo Miyake
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| | - Kenshi Yamasaki
- Department of Dermatology; Graduate School of Medicine; Tohoku University; 1-1 Seiryo-machi Aoba-ku, Sendai 980-8574 Japan
| | - Matsuhiko Nishizawa
- Department of Finemechanics; Graduate School of Engineering; Tohoku University; 6-6-01 Aramaki Aoba-ku, Sendai 980-8579 Japan
| |
Collapse
|
50
|
Lawrence G, Kalimuthu P, Benzigar M, Shelat KJ, Lakhi KS, Park DH, Ji Q, Ariga K, Bernhardt PV, Vinu A. A Nanoporous Cytochrome c Film with Highly Ordered Porous Structure for Sensing of Toxic Vapors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2017; 29:1702295. [PMID: 28961349 DOI: 10.1002/adma.201702295] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Revised: 08/08/2017] [Indexed: 06/07/2023]
Abstract
Creating well-ordered nanoporosity in biomolecules promises stability and activity, offering access to an even wider range of application possibilities. Here, the preparation of nanoporous protein films containing cytochrome c protein molecules is reported through a soft-templating strategy using polystyrene (PS) spheres of different sizes as templates. The stability of the cytochrome c film is demonstrated through electrochemistry studies to show a reusable nature of these films over a long period of time. The size of the PS spheres is varied to tune the pore diameter and the thickness of the cytochrome c films, which are quite stable and highly selective for sensing toxic acidic vapors. The fusion of the templating strategy and the self-assembly of biomolecules may offer various possibilities by generating a new series of porous biomolecules including enzymes with different molecular weights and diameters, peptides, antibodies, and DNA with interesting catalytic, adsorption, sensing, and electronic properties.
Collapse
Affiliation(s)
- Geoffrey Lawrence
- Australian Institute for Bioengineering and Nanotechnology, The University of Queensland, Brisbane, 4072, QLD, Australia
| | - Palraj Kalimuthu
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, 4072, QLD, Australia
| | - Mercy Benzigar
- Future Industries Institute, University of South Australia, Mawson Lakes, Adelaide, 5095, SA, Australia
| | - Kinnari J Shelat
- Australian National Fabrication Facilities - Queensland Node, The University of Queensland, 75 Corner College and Cooper Road, Brisbane, 4072, QLD, Australia
| | - Kripal S Lakhi
- Future Industries Institute, University of South Australia, Mawson Lakes, Adelaide, 5095, SA, Australia
| | - Dae-Hwan Park
- Future Industries Institute, University of South Australia, Mawson Lakes, Adelaide, 5095, SA, Australia
| | - Qingmin Ji
- World Premier International (WPI) Research Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, 305-0044, Japan
| | - Katsuhiko Ariga
- World Premier International (WPI) Research Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba, 305-0044, Japan
| | - Paul V Bernhardt
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, 4072, QLD, Australia
| | - Ajayan Vinu
- Future Industries Institute, University of South Australia, Mawson Lakes, Adelaide, 5095, SA, Australia
| |
Collapse
|