1
|
Brycht M, Poltorak L, Baluchová S, Sipa K, Borgul P, Rudnicki K, Skrzypek S. Electrochemistry as a Powerful Tool for Investigations of Antineoplastic Agents: A Comprehensive Review. Crit Rev Anal Chem 2024; 54:1017-1108. [PMID: 35968923 DOI: 10.1080/10408347.2022.2106117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Cancer is most frequently treated with antineoplastic agents (ANAs) that are hazardous to patients undergoing chemotherapy and the healthcare workers who handle ANAs in the course of their duties. All aspects related to hazardous oncological drugs illustrate that the monitoring of ANAs is essential to minimize the risks associated with these drugs. Among all analytical techniques used to test ANAs, electrochemistry holds an important position. This review, for the first time, comprehensively describes the progress done in electrochemistry of ANAs by means of a variety of bare or modified (bio)sensors over the last four decades (in the period of 1982-2021). Attention is paid not only to the development of electrochemical sensing protocols of ANAs in various biological, environmental, and pharmaceutical matrices but also to achievements of electrochemical techniques in the examination of the interactions of ANAs with deoxyribonucleic acid (DNA), carcinogenic cells, biomimetic membranes, peptides, and enzymes. Other aspects, including the enantiopurity studies, differentiation between single-stranded and double-stranded DNA without using any label or tag, studies on ANAs degradation, and their pharmacokinetics, by means of electrochemical techniques are also commented. Finally, concluding remarks that underline the existence of a significant niche for the basic electrochemical research that should be filled in the future are presented.
Collapse
Affiliation(s)
- Mariola Brycht
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Lukasz Poltorak
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Simona Baluchová
- Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Charles University, Prague 2, Czechia
- Department of Precision and Microsystems Engineering, Delft University of Technology, Delft, The Netherlands
| | - Karolina Sipa
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Paulina Borgul
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Konrad Rudnicki
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Sławomira Skrzypek
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| |
Collapse
|
2
|
Yildir MH, Genc AA, Erk N, Bouali W, Bugday N, Yasar S, Duygulu O. Pioneering electrochemical detection unveils erdafitinib: a breakthrough in anticancer agent determination. Mikrochim Acta 2024; 191:221. [PMID: 38536529 PMCID: PMC10973028 DOI: 10.1007/s00604-024-06318-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/18/2024] [Indexed: 04/09/2024]
Abstract
The successful fabrication is reported of highly crystalline Co nanoparticles interconnected with zeolitic imidazolate framework (ZIF-12) -based amorphous porous carbon using the molten-salt-assisted approach utilizing NaCl. Single crystal diffractometers (XRD), and X-ray photoelectron spectroscopy (XPS) analyses confirm the codoped amorphous carbon structure. Crystallite size was calculated by Scherrer (34 nm) and Williamson-Hall models (42 nm). The magnetic properties of NPCS (N-doped porous carbon sheet) were studied using a vibrating sample magnetometer (VSM). The NPCS has a magnetic saturation (Ms) value of 1.85 emu/g. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses show that Co/Co3O4 nanoparticles are homogeneously distributed in the carbon matrix. While a low melting point eutectic salt acts as an ionic liquid solvent, ZIF-12, at high temperature, leading cobalt nanoparticles with a trace amount of Co3O4 interconnected by conductive amorphous carbon. In addition, the surface area (89.04 m2/g) and pore architectures of amorphous carbon embedded with Co nanoparticles are created using the molten salt approach. Thanks to this inexpensive and effective method, the optimal composite porous carbon structures were obtained with the strategy using NaCl salt and showed distinct electrochemical performance on electrochemical methodology revealing the analytical profile of Erdatifinib (ERD) as a sensor modifier. The linear response spanned from 0.01 to 7.38 μM, featuring a limit of detection (LOD) of 3.36 nM and a limit of quantification (LOQ) of 11.2 nM. The developed sensor was examined in terms of selectivity, repeatability, and reproducibility. The fabricated electrode was utilized for the quantification of Erdafitinib in urine samples and pharmaceutical dosage forms. This research provides a fresh outlook on the advancements in electrochemical sensor technology concerning the development and detection of anticancer drugs within the realms of medicine and pharmacology.
Collapse
Affiliation(s)
- Merve Hatun Yildir
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, 06560, Ankara, Turkey.
- Graduate School of Health Sciences, Ankara University, 06110, Ankara, Turkey.
| | - Asena Ayse Genc
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, 06560, Ankara, Turkey
- Graduate School of Health Sciences, Ankara University, 06110, Ankara, Turkey
| | - Nevin Erk
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, 06560, Ankara, Turkey.
| | - Wiem Bouali
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, 06560, Ankara, Turkey
- Graduate School of Health Sciences, Ankara University, 06110, Ankara, Turkey
| | - Nesrin Bugday
- Department of Chemistry, İnonu University, 44280, Malatya, Turkey
| | - Sedat Yasar
- Department of Chemistry, İnonu University, 44280, Malatya, Turkey
| | - Ozgur Duygulu
- TÜBİTAK Marmara Research Center, Materials Technologies, TÜBİTAK Gebze Campus, 41470, Gebze, Kocaeli, Turkey
| |
Collapse
|
3
|
Ritz AJ, Stuehr OM, Comer DN, Lazenby RA. Controlling Gold Morphology Using Electrodeposition for the Preparation of Electrochemical Aptamer-Based Sensors. ACS APPLIED BIO MATERIALS 2024; 7:1925-1935. [PMID: 38369768 DOI: 10.1021/acsabm.3c01254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
Nanostructuring of gold surfaces to enhance electroactive surface area has proven to significantly enhance the performance of electrochemical aptamer-based (E-AB) sensors, particularly for electrodes on the microscale. Unlike for sensors fabricated on polished gold surfaces, predicting the behavior of E-AB sensors on surfaces with varied gold morphologies becomes more intricate due to the effects of surface roughness and the shapes and sizes of surface features on supporting a self-assembled monolayer. In this study, we explored the impact of gold morphology characteristics on sensor performance, evaluating parameters such as signal change in response to the addition of the target analyte, aptamer probe packing density, and continuous sensing ability. Our findings reveal that surface area enhancement can either enhance or diminish sensor performance for gold nanostructured E-AB sensors, contingent upon the surface morphology. In particular, our results indicate that the aptamer packing density and target analyte signal change results are heavily dependent on gold nanostructure size and features. Sensing surfaces with larger nanoparticle diameters, which were prepared using electrodeposition at a constant potential, had a reduced aptamer packing density and exhibited diminished sensor performance. However, the equivalent packing density of polished electrodes did not yield the equivalent signal change. Other surfaces that were prepared using pulsed waveform electrodeposition achieved optimal signal change with a deposition time, tdep, of 120 s, and increased deposition time with enhanced electroactive surface area resulted in minimized signal changes and more rapid sensor degradation. By investigating sensing surfaces with varied morphologies, we have demonstrated that enhancing the electroactive surface does not always enhance the signal change of the sensor, and aptamer packing density alone does not dictate observed signal change trends. We anticipate that understanding how electrodeposition techniques enhance or diminish sensor performance will pave the way for further exploration of nanostructure-aptamer relationships, contributing to the future development of optimized, miniaturized electrochemical aptamer-based sensors for continuous, in vivo sensing.
Collapse
Affiliation(s)
- Amanda J Ritz
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
| | - Olivia M Stuehr
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
| | - Danté N Comer
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
| | - Robert A Lazenby
- Department of Chemistry & Biochemistry, Florida State University, Tallahassee, Florida 32306, United States
| |
Collapse
|
4
|
Abedi R, Raoof JB, Mohseni M, Bagheri Hashkavayi A. Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria. Anal Biochem 2023; 679:115288. [PMID: 37619902 DOI: 10.1016/j.ab.2023.115288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Acinetobacter baumannii (A. baumannii) is responsible for various nosocomial infections, which is known as a clinically crucial opportunistic pathogen. Therefore, rapid detection of this pathogen is critical to prevent the spread of infection and appropriate treatment. Biological detection probes, such as aptamers and synthetic receptors can be used as diagnostic layers to detect bacteria. In this work, an electrochemical aptasensor was developed for the ultrasensitive detection of A. baumannii by electrochemical impedance spectroscopy (EIS). The aptamer was immobilized on the surface of a CSPE modified with the nanocomposite Fe3O4@SiO2@Glyoxal (Gly) for selective and label-free detection of A. baumannii. The charge transfers resistance (Rct) between redox couple [Fe(CN)63-/4-] and the surface of aptasensor in the Nyquist plot of EIS study was used as electroanalytical signal for detection and determination of A. baumannii. The obtained results showed that the constructed aptasensor could specifically detect A. baumannii in the concentration range from 1.0 × 103-1.0 × 108 Colony-forming unit (CFU)/mL and with a detection limit of 150 CFU/mL (S/N = 3). In addition to its sensitivity, the biosensor exhibits high selectivity over some other pathogens. Therefore, a simple, inexpensive, rapid, label-free, selective, and sensitive electrochemical aptasensor was developed to detect A. baumannii.
Collapse
Affiliation(s)
- Rokhsareh Abedi
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
| | - Mojtaba Mohseni
- Department of Microbiology, Faculty of Science, University of Mazandaran, Iran
| | - Ayemeh Bagheri Hashkavayi
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, United States
| |
Collapse
|
5
|
Er E, Kemal Ateş A. Design of an electrochemical sensing platform based on MoS2-PEDOT:PSS nanocomposite for the detection of epirubicin in biological samples. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
|
6
|
Sohouli E, Ghalkhani M, Zargar T, Ahmadi F. Preparation of a Highly Sensitive Electrochemical Aptasensor for Measuring Epirubicin Based on a Gold Electrode Boosted with Carbon Nano-Onions and MB. BIOSENSORS 2022; 12:1139. [PMID: 36551106 PMCID: PMC9775307 DOI: 10.3390/bios12121139] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 05/31/2023]
Abstract
Epirubicin is prescribed as an essential drug for treating breast, prostate, uterine, and gastrointestinal cancers. It has many side effects, such as heart failure, mouth inflammation, abdominal pain, fever, and shortness of breath. Its measurement is necessary by straightforward and cheap methods. The application of aptamer-based electrochemical sensors is accounted as a selective option for measuring different compounds. In this work, a thiol-modified aptamer was self-assembled on the surface of the gold electrode (AuE) boosted with carbon nano-onions (CNOs), and coupled with methylene blue (MB) as an electroactive tracker to achieve a sensitive and selective aptasensor. In the absence of the epirubicin, CNOs binds to the aptamer through a π-π interaction enhancing the MB electrochemical signal. When epirubicin binds to the aptamer, the adsorption of CNOs and MB to the aptamer is not well established, so the electrochemical signal is reduced, consequently, the epirubicin value can be measured. The prepared aptasensor demonstrated an excellent sensitivity with a curve slope of 0.36 μI/nM, and 3 nM limit of detection in the linear concentration range of 1-75 nM. The prepared aptasensor was accurately capable of measuring epirubicin in blood serum samples.
Collapse
Affiliation(s)
- Esmail Sohouli
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, P.O. Box 16785-163, Tehran 167881-5811, Iran
| | - Masoumeh Ghalkhani
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, P.O. Box 16785-163, Tehran 167881-5811, Iran
| | - Tahereh Zargar
- Electrochemical Sensors Research Laboratory, Department of Chemistry, Faculty of Science, Shahid Rajaee Teacher Training University, Lavizan, P.O. Box 16785-163, Tehran 167881-5811, Iran
| | - Farhad Ahmadi
- Physiology Research Center, Iran University of Medical Sciences, P.O. Box 14665-354, Tehran 141663-4793, Iran
| |
Collapse
|
7
|
Ye Q, Zhang Z, Liu J, Wang X. Screen-printed electrode-based biosensors modified with functional nucleic acid probes and their applications in this pandemic age: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2961-2975. [PMID: 35913361 DOI: 10.1039/d2ay00666a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Electrochemical methodology has probably been the most used sensing platform in the past few years as they provide superior advantages. In particular, screen-printed electrode (SPE)-based sensing applications stand out as they provide extraordinary miniaturized but robust and user-friendly detection system. In this context, we are focusing on the modification of SPE with functional nucleic acid probes and nanostructures to improve the electrochemical detection performance in versatile sensing applications, particularly in the fight against the COVID-19 pandemic. Aptamers are immobilized on the electrode surface to detect non-nucleic acid targets and complementary probes to recognize and capture nucleic acid targets. In a step further, SPE-based biosensors with the modification of self-assembled DNA nanostructures are emphasized as they offer great potential for the interface engineering of the electrode surface and promote the excellent performance of various interface reactions. By equipping with a portable potentiostat and a smartphone monitoring device, the realization of this SPE-based miniaturized diagnostic system for the further requirement of fast and POC detection is revealed. Finally, more novel and excellent works are previewed and future perspectives in this field are mentioned.
Collapse
Affiliation(s)
- Qingqing Ye
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Zhenqi Zhang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Jian Liu
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| | - Xuyao Wang
- Precision Medicine Center, Beilun People's Hospital, Zhejiang University School of Medicine First Affiliated Hospital Beilun Branch, Ningbo, Zhejiang, 315806, P. R. China.
| |
Collapse
|
8
|
Li F, Gao X, Wang X, Guo Y, Sun X, Yang Q, Zhang Y. Ultrasensitive sandwich RNA-aptasensor based on dual-signal amplification strategy for highly sensitive neomycin detection. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108445] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Abedi R, Bakhsh Raoof J, Bagheri Hashkavayi A, Asghary M. Highly sensitive and label-free electrochemical biosensor based on gold nanostructures for studying the interaction of prostate cancer gene sequence with epirubicin anti-cancer drug. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106668] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
10
|
Nalluri LP, Popuri SR, Lee CH, Terbish N. Synthesis of biopolymer coated functionalized superparamagnetic iron oxide nanoparticles for the pH-sensitive delivery of anti-cancer drugs epirubicin and temozolomide. INT J POLYM MATER PO 2021. [DOI: 10.1080/00914037.2020.1785449] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Lakshmi P. Nalluri
- Department of Environmental Engineering, Da-Yeh University, Changhua, R.O.C., Taiwan
| | - Srinivasa R. Popuri
- Department of Biological and Chemical Sciences, The University of the West Indies, Barbados, West Indies
| | - Ching-Hwa Lee
- Department of Environmental Engineering, Da-Yeh University, Changhua, R.O.C., Taiwan
| | - Narangarav Terbish
- Department of Environmental Engineering, Da-Yeh University, Changhua, R.O.C., Taiwan
| |
Collapse
|
11
|
Sui R, Charpentier PA, Marriott RA. Metal Oxide-Related Dendritic Structures: Self-Assembly and Applications for Sensor, Catalysis, Energy Conversion and Beyond. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1686. [PMID: 34199059 PMCID: PMC8308120 DOI: 10.3390/nano11071686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/14/2021] [Accepted: 06/24/2021] [Indexed: 11/16/2022]
Abstract
In the past two decades, we have learned a great deal about self-assembly of dendritic metal oxide structures, partially inspired by the nanostructures mimicking the aesthetic hierarchical structures of ferns and corals. The self-assembly process involves either anisotropic polycondensation or molecular recognition mechanisms. The major driving force for research in this field is due to the wide variety of applications in addition to the unique structures and properties of these dendritic nanostructures. Our purpose of this minireview is twofold: (1) to showcase what we have learned so far about how the self-assembly process occurs; and (2) to encourage people to use this type of material for drug delivery, renewable energy conversion and storage, biomaterials, and electronic noses.
Collapse
Affiliation(s)
- Ruohong Sui
- Department of Chemistry, University of Calgary, Calgary, AB T2L 2K8, Canada
| | - Paul A. Charpentier
- Department of Chemical and Biochemical Engineering, Western University, London, ON N6A 5B9, Canada;
| | - Robert A. Marriott
- Department of Chemistry, University of Calgary, Calgary, AB T2L 2K8, Canada
| |
Collapse
|
12
|
Arunjegan A, Rajaji P, Sivanesan S, Panneerselvam P. A Turn-ON fluorometric biosensor based on ssDNA immobilized with a metal phenolic nanomaterial for the sequential detection of Pb(ii) and epirubicin cancer drug. RSC Adv 2021; 11:12361-12373. [PMID: 35423732 PMCID: PMC8696957 DOI: 10.1039/d1ra00939g] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 03/09/2021] [Indexed: 01/28/2023] Open
Abstract
In this paper, we propose a fluorescent biosensor for the sequential detection of Pb2+ ions and the cancer drug epirubicin (Epn) using the interactions between label-free guanine-rich ssDNA (LFGr-ssDNA), acridine orange (AO), and a metal-phenolic nanomaterial (i.e., nano-monoclinic copper-tannic acid (NMc-CuTA)). An exploration of the sensing mechanism shows that LFGr-ssDNA and AO strongly adsorb on NMc-CuTA through π-π stacking and electrostatic interactions, and this results in the fluorescence quenching of AO. In order to sense the target Pb2+, initially, LFGr-ssDNA specifically binds with Pb2+ ions to form a G4 complex (G-Pb2+-G base pair), which was released from the surface of NMc-CuTA with strong AO fluorescence enhancement (Turn-ON). The subsequent addition of a biothiol, like cysteine (Cys), to the G4 complex decreases the fluorescence, as the Pb2+ ions released from the G4 complex have a higher interaction affinity with the sulfur atoms of Cys; this further induces the unwinding of the G4 complex to form LFGr-ssDNA. Finally, Epn was added to this, which intercalates with LFGr-ssDNA to form a G4 complex via G-Epn-G, resulting in fluorescence recovery (Turn-ON). Accordingly, the Turn-ON fluorescent probe had subsequent limits of detection of 1.5 and 5.6 nM for Pb2+ and Epn, respectively. Hence, the reported NMc-CuTA-based sensing platform has potential applications for the detection of Pb2+ and Epn in real samples with good sensitivity and selectivity.
Collapse
Affiliation(s)
- A Arunjegan
- Department of Chemistry, SRM Institute of Science and Technology Kattankulathur Tamil Nadu 603 203 India +91 9688538842
| | - P Rajaji
- Department of Chemistry, SRM Institute of Science and Technology Kattankulathur Tamil Nadu 603 203 India +91 9688538842
| | - S Sivanesan
- Department of Applied Science and Technology, A. C Technology, Anna University Chennai Tamil Nadu 600 025 India
| | - P Panneerselvam
- Department of Chemistry, SRM Institute of Science and Technology Kattankulathur Tamil Nadu 603 203 India +91 9688538842
| |
Collapse
|
13
|
The Application of Nanomaterials for the Electrochemical Detection of Antibiotics: A Review. MICROMACHINES 2021; 12:mi12030308. [PMID: 33804280 PMCID: PMC8000799 DOI: 10.3390/mi12030308] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/09/2021] [Accepted: 03/12/2021] [Indexed: 12/17/2022]
Abstract
Antibiotics can accumulate through food metabolism in the human body which may have a significant effect on human safety and health. It is therefore highly beneficial to establish easy and sensitive approaches for rapid assessment of antibiotic amounts. In the development of next-generation biosensors, nanomaterials (NMs) with outstanding thermal, mechanical, optical, and electrical properties have been identified as one of the most hopeful materials for opening new gates. This study discusses the latest developments in the identification of antibiotics by nanomaterial-constructed biosensors. The construction of biosensors for electrochemical signal-transducing mechanisms has been utilized in various types of nanomaterials, including quantum dots (QDs), metal-organic frameworks (MOFs), magnetic nanoparticles (NPs), metal nanomaterials, and carbon nanomaterials. To provide an outline for future study directions, the existing problems and future opportunities in this area are also included. The current review, therefore, summarizes an in-depth assessment of the nanostructured electrochemical sensing method for residues of antibiotics in different systems.
Collapse
|
14
|
Safaei M, Shishehbore MR. A review on analytical methods with special reference to electroanalytical methods for the determination of some anticancer drugs in pharmaceutical and biological samples. Talanta 2021; 229:122247. [PMID: 33838767 DOI: 10.1016/j.talanta.2021.122247] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 02/18/2021] [Accepted: 02/19/2021] [Indexed: 02/06/2023]
Abstract
It is widely accepted that cancer, the second leading cause of death, is a morbidity with big impacts on the global health. In the last few years, chemo-therapeutic treatment continually induces alone most lengthy consequents, which is extremely harmful for the physiological and psychological health of the patients. In the present research, we discuss the recent techniques for employed for extraction, and quantitative determination of such compounds in pharmaceutical, and biological specimens. In the frame of this information, this review aims to provide basic principles of chromatography, spectroscopy, and electroanalytical methods for the analysis of anticancer drugs published in the last three years. The review also describes the recent developments regarding enhancing the limit of detection (LOD), the linear dynamic range, and so forth. The results show that the LOD for the chromatographic techniques with the UV detector was obtained equaled over the range 2.0 ng mL-1-0.2 μg mL-1, whereas the LOD values for analysis by chromatographic technique with the mass spectrometry (MS) detector was found between 10.0 pg mL-1-0.002 μg mL-1. The biological fluids could be directly injected to capillary electrophoresis (CE) in cases where the medicine concentration is at the contents greater than mg L-1 or g L-1. Additionally, electrochemical detection of the anticancer drugs has been mainly conducted by the voltammetry techniques with diverse modified electrodes, and lower LODs were estimated between 3.0 ng mL-1-0.3 μg mL-1. It is safe to say that the analyses of anticancer drugs can be achieved by employing a plethora of techniques such as electroanalytical, spectroscopy, and chromatography techniques.
Collapse
Affiliation(s)
- Mohadeseh Safaei
- Department of Chemistry, Yazd Branch, Islamic Azad University, Yazd, Iran
| | | |
Collapse
|
15
|
Yáñez-Sedeño P, González-Cortés A, Campuzano S, Pingarrón JM. Multimodal/Multifunctional Nanomaterials in (Bio)electrochemistry: Now and in the Coming Decade. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2556. [PMID: 33352731 PMCID: PMC7766190 DOI: 10.3390/nano10122556] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/13/2020] [Accepted: 12/16/2020] [Indexed: 01/15/2023]
Abstract
Multifunctional nanomaterials, defined as those able to achieve a combined effect or more than one function through their multiple functionalization or combination with other materials, are gaining increasing attention in the last years in many relevant fields, including cargo targeted delivery, tissue engineering, in vitro and/or in vivo diseases imaging and therapy, as well as in the development of electrochemical (bio)sensors and (bio)sensing strategies with improved performance. This review article aims to provide an updated overview of the important advances and future opportunities exhibited by electrochemical biosensing in connection to multifunctional nanomaterials. Accordingly, representative aspects of recent approaches involving metal, carbon, and silica-based multifunctional nanomaterials are selected and critically discussed, as they are the most widely used multifunctional nanomaterials imparting unique capabilities in (bio)electroanalysis. A brief overview of the main remaining challenges and future perspectives in the field is also provided.
Collapse
Affiliation(s)
- Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | | - Susana Campuzano
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (A.G.-C.); (J.M.P.)
| | | |
Collapse
|
16
|
Ahmadi M, Ghoorchian A, Dashtian K, Kamalabadi M, Madrakian T, Afkhami A. Application of magnetic nanomaterials in electroanalytical methods: A review. Talanta 2020; 225:121974. [PMID: 33592722 DOI: 10.1016/j.talanta.2020.121974] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 11/07/2020] [Accepted: 12/03/2020] [Indexed: 02/08/2023]
Abstract
Magnetic nanomaterials (MNMs) have gained high attention in different fields of studies due to their ferromagnetic/superparamagnetic properties and their low toxicity and high biocompatibility. MNMs contain magnetic elements such as iron and nickel in metallic, bimetallic, metal oxide, and mixed metal oxide. In electroanalytical methods, MNMs have been applied as sorbents for sample preparation before the electrochemical detection (sorbent role), as the electrode modifier (catalytic role), and the integration of the above two roles (as both sorbent and catalytic agent). In this paper, the application of MNMs in electroanalytical methods have been classified based on the main role of the nanomaterial and discussed separately. Furthermore, catalytic activities of MNMs in electroanalytical methods such as redox electrocatalytic, nanozymes catalytic (peroxidase, catalase activity, oxidase activity, superoxide dismutase activity), catalyst gate, and nanocontainer have been discussed.
Collapse
Affiliation(s)
- Mazaher Ahmadi
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran.
| | | | | | | | | | - Abbas Afkhami
- Faculty of Chemistry, Bu-Ali Sina University, Hamedan, Iran.
| |
Collapse
|
17
|
Investigations of antioxidant potential and protective effect of Acanthophora algae on DNA damage: An electrochemical approach. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105455] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
18
|
Sensitive Electrochemical Detection of Tryptophan Using a Hemin/G-Quadruplex Aptasensor. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040100] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this study, we design an electrochemical aptasensor with an enzyme-free amplification method to detect tryptophan (Trp). For the amplified electrochemical signal, the screen-printed electrode was modified with dendritic gold nanostructures (DGNs)/magnetic double-charged diazoniabicyclo [2.2.2] octane dichloride silica hybrid (Fe3O4@SiO2/DABCO) to increase the surface area as well as electrical conductivity, and the hemin/G-quadruplex aptamer was immobilized. The presence of Trp improved the catalytic characteristic of hemin/G-quadruplex structure, which resulted in the efficient catalysis of the H2O2 reduction. As the concentration of Trp increased, the intensity of H2O2 reduction signal increased, and Trp was measured in the range of 0.007–200 nM with a detection limit of 0.002 nM. Compared with previous models, our sensor displayed higher detection sensitivity and specificity for Trp. Furthermore, we demonstrated that the proposed aptasensor successfully determined Trp in human serum samples, thereby proving its practical applicability.
Collapse
|
19
|
Bagheri Hashkavayi A, Cha BS, Lee ES, Kim S, Park KS. Advances in Exosome Analysis Methods with an Emphasis on Electrochemistry. Anal Chem 2020; 92:12733-12740. [PMID: 32902258 DOI: 10.1021/acs.analchem.0c02745] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Exosomes, small extracellular vesicles, are released by various cell types. They are found in bodily fluids, including blood, urine, serum, and saliva, and play essential roles in intercellular communication. Exosomes contain various biomarkers, such as nucleic acids and proteins, that reflect the status of their parent cells. Since they influence tumorigenesis and metastasis in cancer patients, exosomes are excellent noninvasive potential indicators for early cancer detection. Aptamers with specific binding properties have distinct advantages over antibodies, making them effective versatile bioreceptors for the detection of exosome biomarkers. Here, we review various aptamer-based exosome detection approaches based on signaling methods, such as fluorescence, colorimetry, and chemiluminescence, focusing on electrochemical strategies that are easier, cost-effective, and more sensitive than others. Further, we discuss the clinical applications of electrochemical exosome analysis strategies as well as future research directions in this field.
Collapse
Affiliation(s)
- Ayemeh Bagheri Hashkavayi
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Byung Seok Cha
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Eun Sung Lee
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Seokjoon Kim
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea
| | - Ki Soo Park
- Department of Biological Engineering, College of Engineering, Konkuk University, Seoul 05029, Republic of Korea
| |
Collapse
|
20
|
A review on various analytical methods for determination of anthracyclines and their metabolites as anti–cancer chemotherapy drugs in different matrices over the last four decades. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115991] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
21
|
Lu L, Liu B, Leng J, Ma X, Peng H. Electrochemical mixed aptamer-antibody sandwich assay for mucin protein 16 detection through hybridization chain reaction amplification. Anal Bioanal Chem 2020; 412:7169-7178. [PMID: 32761361 DOI: 10.1007/s00216-020-02849-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/20/2020] [Accepted: 07/27/2020] [Indexed: 01/24/2023]
Abstract
A mixed aptamer-antibody sandwich assay for the determination of mucin protein 16 (MUC16) was developed based on hybridization chain reaction (HCR) with methylene blue (MB) as an electrochemical indicator. First, MUC16 antibody was adsorbed onto the surface of the Au nanoparticle (AuNP)-modified indium tin oxide (ITO) electrode to effectively capture the target MUC16. After MUC16 was captured by the MUC16 aptamer, an antibody/MUC16/aptamer sandwich structure formed for the highly selective detection of MUC16. The 3' end of the aptamer was then subjected to HCR with the assistance of auxiliary probes to obtain DNA concatemers. Numerous MB molecules bonded with G bases in the DNA concatemers by immersing the modified ITO electrode into a stirred solution containing MB with KCl. Stepwise changes in the microscopic features of the electrode surface were studied by scanning electron microscopy (SEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to characterize the electrochemical behavior of the different modified electrodes. The oxidation current of MB was detected by differential pulse voltammetry (DPV). Under the optimum conditions, the proposed mixed aptamer-antibody sandwich assay showed wide dynamic range from 0.39 to 200 unit mL-1 with a low detection limit of 0.02 unit mL-1 (S/N ratio = 3). The proposed method showed good accuracy, selectivity, and acceptable reproducibility. Graphical abstract An electrochemical mixed aptamer-antibody sandwich assay based on the aptamer-induced HCR amplification strategy was fabricated for the highly sensitive detection of MUC16. The mixed aptamer-antibody sandwich assay showed acceptable performance of detection range, detection limit, reproducibility, and selectivity.
Collapse
Affiliation(s)
- Lingsong Lu
- Department of Central Laboratory, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China.
| | - Bei Liu
- Department of Reproductive Genetics, Women's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China
| | - Jianhang Leng
- Department of Central Laboratory, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China
| | - Xiao Ma
- Department of Central Laboratory, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China
| | - Huihui Peng
- Department of Central Laboratory, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou, 310006, Zhejiang, China
| |
Collapse
|
22
|
Sahebi H, Konoz E, Ezabadi A, Niazi A, Ahmadi SH. Sensitive Determination of Imatinib Mesylate in Human Plasma Using DABCO-Based Ionic Liquid-Modified Magnetic Nanoparticles. Chromatographia 2020. [DOI: 10.1007/s10337-020-03923-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
23
|
Sahebi H, Konoz E, Ezabadi A, Niazi A, Ahmadi SH. Simultaneous determination of five penicillins in milk using a new ionic liquid-modified magnetic nanoparticle based dispersive micro-solid phase extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104605] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
24
|
Pérez-Fernández B, Costa-García A, Muñiz ADLE. Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes. BIOSENSORS 2020; 10:E32. [PMID: 32252430 PMCID: PMC7236603 DOI: 10.3390/bios10040032] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 03/27/2020] [Accepted: 03/30/2020] [Indexed: 12/12/2022]
Abstract
Pesticides are among the most important contaminants in food, leading to important global health problems. While conventional techniques such as high-performance liquid chromatography (HPLC) and mass spectrometry (MS) have traditionally been utilized for the detection of such food contaminants, they are relatively expensive, time-consuming and labor intensive, limiting their use for point-of-care (POC) applications. Electrochemical (bio)sensors are emerging devices meeting such expectations, since they represent reliable, simple, cheap, portable, selective and easy to use analytical tools that can be used outside the laboratories by non-specialized personnel. Screen-printed electrodes (SPEs) stand out from the variety of transducers used in electrochemical (bio)sensing because of their small size, high integration, low cost and ability to measure in few microliters of sample. In this context, in this review article, we summarize and discuss about the use of SPEs as analytical tools in the development of (bio)sensors for pesticides of interest for food control. Finally, aspects related to the analytical performance of the developed (bio)sensors together with prospects for future improvements are discussed.
Collapse
Affiliation(s)
| | | | - Alfredo de la Escosura- Muñiz
- NanoBioAnalysis Group-Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, 33006 Oviedo, Spain
| |
Collapse
|
25
|
Sensors design based on hybrid gold-silica nanostructures. Biosens Bioelectron 2020; 153:112054. [DOI: 10.1016/j.bios.2020.112054] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Revised: 01/11/2020] [Accepted: 01/25/2020] [Indexed: 12/14/2022]
|
26
|
Joshi A, Kim KH. Recent advances in nanomaterial-based electrochemical detection of antibiotics: Challenges and future perspectives. Biosens Bioelectron 2020; 153:112046. [DOI: 10.1016/j.bios.2020.112046] [Citation(s) in RCA: 83] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Revised: 12/20/2019] [Accepted: 01/20/2020] [Indexed: 12/16/2022]
|
27
|
|
28
|
Raoof JB, Bagheryan Z, Hashkavayi AB. Development of a DNA biosensor based on MCM41 modified screen-printed graphite electrode for the study of the short sequence of the p53 tumor suppressor gene in hybridization and its interaction with the flutamide drug using hemin as the electrochemical label. NEW J CHEM 2020. [DOI: 10.1039/c9nj04569d] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Electrochemical DNA biosensors are particularly attractive because of their high sensitivity, suitability and compatibility with miniaturization in nucleic acid technology.
Collapse
Affiliation(s)
- Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory
- Department of Analytical Chemistry
- Faculty of Chemistry
- University of Mazandaran
- Babolsar
| | - Zahra Bagheryan
- Electroanalytical Chemistry Research Laboratory
- Department of Analytical Chemistry
- Faculty of Chemistry
- University of Mazandaran
- Babolsar
| | - Ayemeh Bagheri Hashkavayi
- Electroanalytical Chemistry Research Laboratory
- Department of Analytical Chemistry
- Faculty of Chemistry
- University of Mazandaran
- Babolsar
| |
Collapse
|
29
|
An Nd 3+-Sensitized Upconversion Fluorescent Sensor for Epirubicin Detection. NANOMATERIALS 2019; 9:nano9121700. [PMID: 31795129 PMCID: PMC6955805 DOI: 10.3390/nano9121700] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 11/23/2019] [Accepted: 11/26/2019] [Indexed: 12/15/2022]
Abstract
We describe here an Nd3+-sensitized upconversion fluorescent sensor for epirubicin (EPI) detection in aqueous solutions under 808 nm laser excitation. The upconversion fluorescence of nanoparticles is effectively quenched in the presence of EPI via a fluorescence resonance energy transfer mechanism. The dynamic quenching constant was 2.10 × 104 M−1. Normalized fluorescence intensity increased linearly as the EPI concentration was raised from 0.09 μM to 189.66 μM and the fluorometric detection limit was 0.05 μM. The sensing method was simple, fast, and low-cost and was able to be applied to determine the levels of EPI in urine with spike recoveries from 97.5% to 102.6%. Another important feature of the proposed fluorescent sensor is that it holds a promising potential for in vivo imaging and detection due to its distinctive properties such as weak autofluorescence, low heating effect, and high light penetration depth.
Collapse
|
30
|
Zhang T, Song Y, Xing Y, Gu Y, Yan X, Liu H, Lu N, Xu H, Xu Z, Zhang Z, Yang M. The synergistic effect of Au-COF nanosheets and artificial peroxidase Au@ZIF-8(NiPd) rhombic dodecahedra for signal amplification for biomarker detection. NANOSCALE 2019; 11:20221-20227. [PMID: 31621739 DOI: 10.1039/c9nr07190c] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Here, a new type of signal amplification strategy is proposed employing Au nanoparticle (AuNP)-functionalized covalent organic framework (Au-COF) nanosheets and AuNP functionalized ZIF-8(NiPd) (Au@ZIF-8(NiPd)) rhombic dodecahedra nanocomposites for sandwich electrochemical sensor construction. The peroxidase mimics Au@ZIF-8(NiPd) took the place of natural enzymes in enzyme-assisted amplification strategies, both acting as catalysts for H2O2 reduction for signal amplification, and serving as ideal nanocarriers for signal probe anchoring. The cancer biomarker thrombin (TB) was selected as the target. Thrombin binding aptamers (TBA 2) were fixed on Au@ZIF-8(NiPd), and the obtained TBA 2-Au@ZIF-8(NiPd) bioconjugates were employed as tracer labels, and TB was sandwiched between the tracer labels and capture probe TBA 1 which were immobilized on the Au-COF nanosheet modified electrode. Au-COFs with a high specific area, super electroconductivity, and uniformly distributed AuNPs were utilized as the electrode substrate to fix TBA 1. Exploiting the sandwich method, the proposed TB aptasensor exhibited a wide linear range of 0.1 pM to 20 nM with a low detection limit of 15 fM (S/N = 3). The ingenious sensing strategy enriched the application diversity of the artificial enzyme and showed promise in research and development of point-of-care diagnostics.
Collapse
Affiliation(s)
- Tingting Zhang
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Yu Song
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Yue Xing
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Yue Gu
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Xiaoyi Yan
- College of Chemistry, Jilin University, Changchun 130012, China
| | - He Liu
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Nannan Lu
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Haixin Xu
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Zhiqian Xu
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Zhiquan Zhang
- College of Chemistry, Jilin University, Changchun 130012, China
| | - Ming Yang
- Department of Breast Surgery, First Hospital, Jilin University, Changchun 130012, China
| |
Collapse
|
31
|
Rahimi‐Mohseni M, Raoof JB, Aghajanzadeh TA, Ojani R. Rapid Determination of Phenolic Compounds in Water Samples: Development of a Paper‐based Nanobiosensor Modified with Functionalized Silica Nanoparticles and Potato Tissue. ELECTROANAL 2019. [DOI: 10.1002/elan.201800780] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Mohadeseh Rahimi‐Mohseni
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of ChemistryUniversity of Mazandaran Babolsar Iran
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of ChemistryUniversity of Mazandaran Babolsar Iran
| | | | - Reza Ojani
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of ChemistryUniversity of Mazandaran Babolsar Iran
| |
Collapse
|
32
|
Sahebi H, Konoz E, Ezabadi A. Synthesis of DABCO-based ionic liquid functionalized magnetic nanoparticles as a novel sorbent for the determination of cephalosporins in milk samples by dispersive solid-phase extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry. NEW J CHEM 2019. [DOI: 10.1039/c9nj02200g] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In this study, DABCO-based ionic liquid-functionalized magnetic iron oxide nanoparticles were synthesized for the first time by the quaternization reaction with 1-(2,3-dihydroxypropyl)-1,4-diazabicyclo[2.2.2]octanylium chloride and chloro-functionalized Fe3O4 nanoparticles.
Collapse
Affiliation(s)
- Hamed Sahebi
- Department of Chemistry
- Faculty of Science
- Azad University Central Tehran Branch
- Tehran
- Iran
| | - Elaheh Konoz
- Department of Chemistry
- Faculty of Science
- Azad University Central Tehran Branch
- Tehran
- Iran
| | - Ali Ezabadi
- Department of Chemistry
- Faculty of Science
- Azad University Central Tehran Branch
- Tehran
- Iran
| |
Collapse
|
33
|
Ultrasensitive and reusable electrochemical aptasensor for detection of tryptophan using of [Fe(bpy) 3](p-CH 3C 6H 4SO 2) 2 as an electroactive indicator. J Pharm Biomed Anal 2018; 163:180-187. [PMID: 30316063 DOI: 10.1016/j.jpba.2018.10.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2018] [Revised: 09/24/2018] [Accepted: 10/02/2018] [Indexed: 02/01/2023]
Abstract
In this paper, we report the application of a reusable electrochemical aptasensor for detection of tryptophan by using [Fe(bpy)3](p-CH3C6H4SO2)2 as an electroactive indicator and based on the target-compelled aptamer displacement. The aptasensor fabricated by self-assembling the thiolated probe on the surface of graphite screen-printed electrode modified with gold nanoparticles/multiwalled carbon nanotubes and chitosan nanocomposite (AuNPs/MWCNTs-Chit/SPE). Afterward, Trp aptamer (Apt) immobilized on the modified electrode surface through hybridization. In the absence of Trp, a sharp peak of [Fe(bpy)3](p-CH3C6H4 SO2)2 can be observed in differential pulse voltammetry (DPV) study. The introduction of Trp led to the formation of aptamer-Trp complex and dissociation of the aptamer from the DNA-Apt duplex on the electrode surface into the solution and decreases the peak current intensity of electroactive indicator. This is because, [Fe(bpy)3](p-CH3C6H4SO2)2 tends to bind to the two strands DNA. Therefore, the peak current of [Fe(bpy)3](p-CH3C6H4 SO2)2 linearly decreased with increasing the concentration of Trp over a range of 3.0 nM- 100 μM. The detection limit (3 σ) was 1.0 nM. In addition, we examined the selectivity of the constructed biosensor for tyrosine, histidine, arginine, lysine, valine and methionine that belonged to the amino acid family. The obtained results showed that the fabricated sensor had a good selectivity for Trp against the other examined amino acids. Also, the potential applicability of the aptasensor was investigated by detecting the Trp in a complex media such as human blood plasma spiked with Trp.
Collapse
|
34
|
Yu S, Li H, Li G, Niu L, Liu W, Di X. Reduced graphene oxide-supported gold dendrite for electrochemical sensing of acetaminophen. Talanta 2018; 184:244-250. [DOI: 10.1016/j.talanta.2018.03.011] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 02/28/2018] [Accepted: 03/07/2018] [Indexed: 11/26/2022]
|
35
|
Khoshbin Z, Housaindokht MR, Verdian A, Bozorgmehr MR. Simultaneous detection and determination of mercury (II) and lead (II) ions through the achievement of novel functional nucleic acid-based biosensors. Biosens Bioelectron 2018; 116:130-147. [PMID: 29879539 DOI: 10.1016/j.bios.2018.05.051] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 05/26/2018] [Accepted: 05/28/2018] [Indexed: 02/07/2023]
Abstract
The serious threats of mercury (Hg2+) and lead (Pb2+) ions for the public health makes it important to achieve the detection methods of the ions with high affinity and specificity. Metal ions usually coexist in some environment and foodstuff or clinical samples. Therefore, it is very necessary to develop a fast and simple method for simultaneous monitoring the amount of metal ions, especially when Hg2+ and Pb2+ coexist. DNAzyme-based biosensors and aptasensors have been highly regarded for this purpose as two main groups of the functional nucleic acid (FNA)-based biosensors. In this review, we summarize the recent achievements of functional nucleic acid-based biosensors for the simultaneous detection of Hg2+ and Pb2+ ions in two main optical and electrochemical groups. The tremendous interest in utilizing the various nanomaterials is also highlighted in the fabrication of the FNA-based biosensors. Finally, some results are presented based on the advantages and disadvantages of the studied FNA-based biosensors to compare their validation.
Collapse
Affiliation(s)
- Zahra Khoshbin
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran
| | | | - Asma Verdian
- Department of Food Safety and Quality Control, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran
| | | |
Collapse
|
36
|
Munteanu FD, Titoiu AM, Marty JL, Vasilescu A. Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes. SENSORS 2018; 18:s18030901. [PMID: 29562637 PMCID: PMC5877114 DOI: 10.3390/s18030901] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 03/12/2018] [Accepted: 03/15/2018] [Indexed: 12/19/2022]
Abstract
This review provides a brief overview of the fabrication and properties of screen-printed electrodes and details the different opportunities to apply them for the detection of antibiotics, detection of bacteria and antibiotic susceptibility. Among the alternative approaches to costly chromatographic or ELISA methods for antibiotics detection and to lengthy culture methods for bacteria detection, electrochemical biosensors based on screen-printed electrodes present some distinctive advantages. Chemical and (bio)sensors for the detection of antibiotics and assays coupling detection with screen-printed electrodes with immunomagnetic separation are described. With regards to detection of bacteria, the emphasis is placed on applications targeting viable bacterial cells. While the electrochemical sensors and biosensors face many challenges before replacing standard analysis methods, the potential of screen-printed electrodes is increasingly exploited and more applications are anticipated to advance towards commercial analytical tools.
Collapse
Affiliation(s)
- Florentina-Daniela Munteanu
- Faculty of Food Engineering, Tourism and Environmental Protection, "Aurel Vlaicu" University of Arad, Elena Dragoi, No. 2, Arad 310330, Romania.
| | - Ana Maria Titoiu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, Bucharest 060101, Romania.
| | - Jean-Louis Marty
- BAE Laboratory, Université de Perpignan via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France.
| | - Alina Vasilescu
- International Centre of Biodynamics, 1B Intrarea Portocalelor, Bucharest 060101, Romania.
| |
Collapse
|
37
|
A novel colorimetric aptasensor for ultrasensitive detection of cocaine based on the formation of three-way junction pockets on the surfaces of gold nanoparticles. Anal Chim Acta 2018; 1020:110-115. [PMID: 29655421 DOI: 10.1016/j.aca.2018.02.066] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 02/22/2018] [Accepted: 02/27/2018] [Indexed: 12/16/2022]
Abstract
Herein, a novel colorimetric aptasensor was introduced for detection of cocaine based on the formation of three-way junction pockets on the surfaces of gold nanoparticles (AuNPs) and the catalytic activity of the surfaces of AuNPs. Simplicity and detection of cocaine in a short time (only 35 min) are some of the unique features of the proposed sensing strategy. In the presence of cocaine, triple-fragment aptamer (TFA) forms on the surfaces of AuNPs, leading to a significant decrease of the catalytic activity of AuNPs and the color of samples remains yellow. In the absence of target, TFA does not form on the surfaces of AuNPs and 4-Nitrophenol, as a colorimetric agent, has more access to the surfaces of AuNPs, resulting in the reduction of 4-Nitrophenol and the color of sample changes from yellow to colorless. The sensing strategy showed good specificity, a limit of detection (LOD) of 440 pM and a dynamic range over 2-100 nM. The sensing method was also successfully applied to detect cocaine in spiked human serum samples with recovery of 94.71-98.63%.
Collapse
|
38
|
Hashkavayi AB, Raoof JB, Ojani R. Preparation of Epirubicin Aptasensor Using Curcumin as Hybridization Indicator: Competitive Binding Assay between Complementary Strand of Aptamer and Epirubicin. ELECTROANAL 2017. [DOI: 10.1002/elan.201700645] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Ayemeh Bagheri Hashkavayi
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry; University of Mazandaran; Babolsar IranTel.: +98 11 353 02392Fax: +98 11 353 02350
| | - Jahan Bakhsh Raoof
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry; University of Mazandaran; Babolsar IranTel.: +98 11 353 02392Fax: +98 11 353 02350
| | - Reza Ojani
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry; University of Mazandaran; Babolsar IranTel.: +98 11 353 02392Fax: +98 11 353 02350
| |
Collapse
|
39
|
Verdian A. Apta-nanosensors for detection and quantitative determination of acetamiprid - A pesticide residue in food and environment. Talanta 2017; 176:456-464. [PMID: 28917776 DOI: 10.1016/j.talanta.2017.08.070] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Revised: 08/21/2017] [Accepted: 08/21/2017] [Indexed: 10/19/2022]
Abstract
In an effort to achieve high sensitive and selective detection of pesticide residues, numerous nanomaterial-based aptasensors are currently being developed for acetamiprid analysis. Recently, aptamers as a potent alternative of antibodies are used in biosensing platforms. There is tremendous interest in utilizing of nanomaterial as basic building blocks and signaling elements in aptasensors. The nanomaterials have the unique optical and electrical properties. The combination of nanomaterial and aptamer technology has opened a new window in pesticide residues monitoring. In this review, recent advances and applications of optical and electrochemical nanomaterial-based aptasensors for the detection and quantitative determination of acetamiprid in details have been discussed.
Collapse
Affiliation(s)
- Asma Verdian
- Department of Food Nanotechnology, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran.
| |
Collapse
|
40
|
Wu Y, Zou L, Lei S, Yu Q, Ye B. Highly sensitive electrochemical thrombin aptasensor based on peptide-enhanced electrocatalysis of hemin/G-quadruplex and nanocomposite as nanocarrier. Biosens Bioelectron 2017. [PMID: 28622642 DOI: 10.1016/j.bios.2017.06.023] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
In this work, we first conjugated a short peptide to thrombin binding aptamer (TBA) and bond hemin to the hybrid, effectively rendering hemin/G4-peptide more active over the original hemin/G4, so that a highly sensitive electrochemical thrombin (TB) aptasensor was developed based on it and PtNTs@rGO nanocomposite. It was the first report on the application of hemin/G4-peptide in electrochemical aptasensor. PtNTs@rGO with large surface area served as excellent nanocarrier for high loading of hemin/G4-peptide hybrids, resulting in the formation of hemin/G4-peptide-PtNTs@rGO bioconjugate as the secondary aptamer and further signal enhancement. The specific affinity of aptamer for target TB made the secondary aptamer go into the sensing interface, and then a noticeable current signal was obtained from hemin without additional redox mediators. Due to the collaborative electrocatalysis of hemin/G4-peptide and PtNTs toward H2O2, which was formed in situ during the process of hemin/G4-peptide-catalyzed oxidation of NADH with dissolved O2, the current intensity increased dramatically. Such an electrochemical aptasensing system could be used to detect TB with a linear range of 0.05 pM-60nM and very lower detection limit of 15fM. Notably, this method exhibited a higher sensitivity than that of many hemin/G4-based electrochemical strategies for TB detection due to the improvement of the catalytic activity of hemin/G4-peptide. The present works opened a new way for expanding the application of hemin/G4 in biological detection. With the mediator-free, proteinous enzyme-free yet high-sensitivity advantages, this electrochemical aptasensor held great promise for other biomarker detections in clinical diagnostics.
Collapse
Affiliation(s)
- Yongmei Wu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Lina Zou
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Sheng Lei
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Qian Yu
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China
| | - Baoxian Ye
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, PR China.
| |
Collapse
|