1
|
Wang T, Shi Z, Zhong Y, Ma Y, He J, Zhu Z, Cheng XB, Lu B, Wu Y. Biomass-Derived Materials for Advanced Rechargeable Batteries. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2310907. [PMID: 39051510 DOI: 10.1002/smll.202310907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 01/10/2024] [Indexed: 07/27/2024]
Abstract
Biomass-derived materials generally exhibit uniform and highly-stable hierarchical porous structures that can hardly be achieved by conventional chemical synthesis and artificial design. When used as electrodes for rechargeable batteries, these structural and compositional advantages often endow the batteries with superior electrochemical performances. This review systematically introduces the innate merits of biomass-derived materials and their applications as the electrode for advanced rechargeable batteries, including lithium-ion batteries, sodium-ion batteries, potassium-ion batteries, and metal-sulfur batteries. In addition, biomass-derived materials as catalyst supports for metal-air batteries, fuel cells, and redox-flow batteries are also included. The major challenges for specific batteries and the strategies for utilizing biomass-derived materials are detailly introduced. Finally, the future development of biomass-derived materials for advanced rechargeable batteries is prospected. This review aims to promote the development of biomass-derived materials in the field of energy storage and provides effective suggestions for building advanced rechargeable batteries.
Collapse
Affiliation(s)
- Tao Wang
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Zezhong Shi
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Yiren Zhong
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Yuan Ma
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Jiarui He
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Zhi Zhu
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Xin-Bing Cheng
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| | - Bingan Lu
- School of Physics and Electronics, Hunan University, Changsha, 410082, P. R. China
| | - Yuping Wu
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Confucius Energy Storage Lab, School of Energy and Environment, Southeast University, Nanjing, 211189, P. R. China
| |
Collapse
|
2
|
Magar HS, El Nahrawy AM, Hassan RYA, Abou Hammad AB. Nanohexagonal iron barium titanate nanoparticles surface-modified NiFe 2O 4 composite screen-printed electrode for enzymatic glucose monitoring. RSC Adv 2024; 14:34948-34963. [PMID: 39493544 PMCID: PMC11528421 DOI: 10.1039/d4ra06689h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Accepted: 10/24/2024] [Indexed: 11/05/2024] Open
Abstract
A nanocomposite of iron barium titanate/NiFe2O4 (FBT/NF) was synthesized using sol-gel techniques to form organized hexagonal structures. The effects of NiFe2O4 nanostructures on FBT's phase purity, morphology, and dielectric properties were systematically explored and intensively discussed. TEM imaging confirmed the hexagonal structure, and electrical measurements revealed that para-electric NF influenced the conductivity and impedance of ferroelectric FBT, with a shift in Curie temperature to lower values. The FBT/NF nanocomposite was optimized for use in glucose amperometric biosensors, offering fast and direct electron transfer from glucose oxidase that was chemically immobilized on disposable sensor chips. Thus, the biosensor exhibited high sensitivity (757.14 μA mM-1 cm-2), a fast response time of 50 seconds, and a wide linear range of 0.0027-1.9 mM with a low detection limit of 0.5 μM. Accordingly, the biosensor was exploited for blood glucose detection, showing high precision compared to reference methods. These findings highlighted the potential of the FBT/NF nanocomposite for use in developing biosensor portable devices.
Collapse
Affiliation(s)
- Hend S Magar
- Applied Organic Chemistry Department, National Research Centre (NRC) Dokki Giza 12622 Egypt +201121926682
| | - Amany M El Nahrawy
- Solid State Physics Department, Physics Research Division, National Research Centre 33 El Bohouth St., Dokki Giza 12622 Egypt
| | - Rabeay Y A Hassan
- Applied Organic Chemistry Department, National Research Centre (NRC) Dokki Giza 12622 Egypt +201121926682
- Biosensors Research Lab, University of Science and Technology (UST), Zewail City of Science and Technology 6th October City Giza 12578 Egypt
| | - Ali B Abou Hammad
- Solid State Physics Department, Physics Research Division, National Research Centre 33 El Bohouth St., Dokki Giza 12622 Egypt
| |
Collapse
|
3
|
Wei Y, Zhou S, Wei J, Cai H, Hou Y, Jia Z, Su X. Carbon Dot-Stabilized Hydrogel Composite: A New Adsorbent for Efficient and Sustainable Pb(II) Removal. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:9651-9660. [PMID: 38656101 DOI: 10.1021/acs.langmuir.4c00469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
In this paper, a carbon dot hydrogel composite (CDs-Hy) capable of efficiently removing Pb(II) was prepared by hydrogen bonding self-assembly in combination with carbon dots and a hydrogel. CDs-Hy was characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and X-ray photoelectron spectroscopy (XPS), and the effect of the adsorption conditions on the adsorption efficiency of CDs-Hy was studied. The results of the study showed that the incorporation of carbon dots, on the one hand, significantly increased the adsorption capacity of the material. On the other hand, it can increase the stability of hydrogels in aqueous solution. The possible adsorption mechanisms were further verified as ion exchange and coordination. CDs-Hy is a novel adsorbent material capable of removing Pb2+ efficiently, which can be reused several times with high stability.
Collapse
Affiliation(s)
- Yuan Wei
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Shunli Zhou
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Ju Wei
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Huishan Cai
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Yongrui Hou
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Zhenfu Jia
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| | - Xiaodong Su
- School of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China
| |
Collapse
|
4
|
Liu Y, Zhu Y, Chen L, Li Y, Wang L. Ni/WS 2/WC Composite Nanosheets as an Efficient Catalyst for Photoelectrochemical Hydrogen Peroxide Sensing and Hydrogen Evolution. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1037. [PMID: 38473509 DOI: 10.3390/ma17051037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/12/2024] [Accepted: 02/21/2024] [Indexed: 03/14/2024]
Abstract
It is highly attractive to develop a photoelectrochemical (PEC) sensing platform based on a non-noble-metal nano array architecture. In this paper, a PEC hydrogen peroxide (H2O2) biosensor based on Ni/WS2/WC heterostructures was synthesized by a facile hydrothermal synthesis method and melamine carbonization process. The morphology, structural and composition and light absorption properties of the Ni/WS2/WC catalyst were investigated by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and UV-visible spectrophotometer. The average size of the Ni/WS2/WC nanosheets was about 200 nm. Additionally, the electrochemical properties toward H2O2 were studied using an electrochemical workstation. Benefiting from the Ni and C atoms, the optimized Ni/WS2/WC catalyst showed superior H2O2 sensing performance and a large photocurrent response. It was found that the detection sensitivity of the Ni/WS2/WC catalyst was 25.7 μA/cm2/mM, and the detection limit was 0.3 mmol/L in the linear range of 1-10 mM. Simultaneously, the synthesized Ni/WS2/WC electrode displayed excellent electrocatalytic properties in hydrogen evolution reaction (HER), with a relatively small overpotential of 126 mV at 10 mA/cm2 in 0.5 M H2SO4. This novel Ni/WS2/WC electrode may provide new insights into preparing other efficient hybrid photoelectrodes for PEC applications.
Collapse
Affiliation(s)
- Yanping Liu
- School of Physical Education, Shanxi Normal University, Taiyuan 030032, China
| | - Yixin Zhu
- School of Physical Education, Shanxi Normal University, Taiyuan 030032, China
| | - Leqin Chen
- School of Physical Education, Shanxi Normal University, Taiyuan 030032, China
| | - Yujia Li
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education, School of Chemical and Material Science, Shanxi Normal University, Taiyuan 030032, China
| | - Lanfang Wang
- Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education, School of Chemical and Material Science, Shanxi Normal University, Taiyuan 030032, China
| |
Collapse
|
5
|
Chopra T, Parkesh R. Microwave-Assisted Synthesis of Functionalized Carbon Nanospheres Using Banana Peels: pH-Dependent Synthesis, Characterization, and Selective Sensing Applications. ACS OMEGA 2024; 9:4555-4571. [PMID: 38313540 PMCID: PMC10831994 DOI: 10.1021/acsomega.3c07544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/15/2023] [Accepted: 12/22/2023] [Indexed: 02/06/2024]
Abstract
This work presents a microwave-based green synthesis method for producing carbon nanospheres (CNSs) and investigates the impact of presynthesis pH on their size and assembly. The resulting CNSs are monodispersed, averaging 35 nm in size, and exhibit notable characteristics including high water solubility, photostability, and a narrow size distribution, achieved within a synthesis time of 15 min. The synthesized CNS features functional groups such as -OH, -COOH, -NH, -C-O-C, =C-H, and -CH. This diversity empowers the CNS for various applications including sensing. The CNS exhibits a distinct UV peak at 282 nm and emits intense fluorescence at 430 nm upon excitation at 350 nm. These functionalized CNSs enable selective and specific sensing of Cu2+ ions and the amino acid tryptophan (Trp) in aqueous solutions. In the presence of Cu2+ ions, static-based quenching of CNS fluorescence was observed due to the chelation-enhanced quenching (CHEQ) effect. Notably, Cu2+ ions induce a substantial change in UV spectra alongside a red-shift in the peak position. The limits of detection and quantification for Cu2+ ions with CNS are determined as 0.73 and 2.45 μg/mL, respectively. Additionally, on interaction with tryptophan, the UV spectra of CNS display a marked increase in the peak at 282 nm, accompanied by a red-shift phenomenon. The limits of detection and quantification for l-tryptophan are 4.510 × 10-3 and 1.50 × 10-2 μg/mL, respectively, indicating its significant potential for biological applications. Furthermore, the practical applicability of CNSs is demonstrated by their successful implementation in analyzing real water samples and filter paper-based examination, showcasing their effectiveness for on-site sensing.
Collapse
Affiliation(s)
- Tavishi Chopra
- CSIR-Institute
of Microbial Technology, Chandigarh 160036, India
- Academy
of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, Uttar Pradesh, India
| | - Raman Parkesh
- CSIR-Institute
of Microbial Technology, Chandigarh 160036, India
| |
Collapse
|
6
|
Saputra E, Prawiranegara BA, Nugraha MW, Oh WD, Sugesti H, Evelyn, Utama PS. 3D N-doped carbon derived from zeolitic imidazole framework as heterogeneous catalysts for decomposition of pulp and paper mill effluent: Optimization and kinetics study. ENVIRONMENTAL RESEARCH 2023; 234:116441. [PMID: 37331558 DOI: 10.1016/j.envres.2023.116441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 05/31/2023] [Accepted: 06/15/2023] [Indexed: 06/20/2023]
Abstract
Three specific catalysts, namely ZIF-67 (zeolitic imidazolate framework-67), Co@NCF (Co@Nitrogen-Doped Carbon Framework), and 3D NCF (Three-Dimensional Nitrogen-Doped Carbon Framework), were prepared and studied for pulp and paper mill effluent degradation using heterogeneous activation of peroxymonosulfate (PMS). Numerous characterizations, including scanning electron microscopy (SEM), X-ray diffraction (XRD), and N2 adsorption, were used to characterize the properties of three different catalysts. 3D NCF is remarkably effective at heterogeneous activation of PMS to generate sulfate radicals to degrade pulp and paper mill effluent (PPME) compared to the other as-prepared catalysts. The catalytic activity reveals a sequence of 3D NCF > Co@NCF > ZIF-67.3D NCF could degrade organic pollutants in 30 min at an initial COD concentration of 1146 mg/L of PPME, 0.2 g/L catalysts, 2 g/L PMS, and 50 °C. Consequently, it was observed that the degradation of PPME using 3D NCF followed first-order kinetics, with an activation energy of 40.54 kJ mol-1. Overall, 3D NCF/PMS system reveals promising performance for PPME removal.
Collapse
Affiliation(s)
- Edy Saputra
- Department of Chemical Engineering, Universitas Riau, Pekanbaru, 28293, Indonesia.
| | - Barata Aditya Prawiranegara
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Riau, Pekanbaru, 28293, Indonesia
| | - Muhammad Wahyu Nugraha
- Department of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama, 700-8530, Japan
| | - Wen-Da Oh
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Penang, Malaysia
| | - Heni Sugesti
- Department of Chemical Engineering, Universitas Riau, Pekanbaru, 28293, Indonesia
| | - Evelyn
- Department of Chemical Engineering, Universitas Riau, Pekanbaru, 28293, Indonesia
| | - Panca Setia Utama
- Department of Chemical Engineering, Universitas Riau, Pekanbaru, 28293, Indonesia
| |
Collapse
|
7
|
Song P, Qu P, Wang M, Wang AJ, Xue Y, Mei LP, Feng JJ. Self-checking dual-modal aptasensor based on hybrid Z-scheme heterostructure of Zn-defective CdS/ZnS for oxytetracycline detection. Anal Chim Acta 2023; 1274:341542. [PMID: 37455075 DOI: 10.1016/j.aca.2023.341542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 06/15/2023] [Accepted: 06/16/2023] [Indexed: 07/18/2023]
Abstract
Electrochemical detection methods have been widely used for trace target detection with satisfactory results. However, most of the existing electrochemical sensors rely only on single signal output, which inevitably suffer from the interference of the complex matrix of real samples. Herein, we proposed a dual-modal aptasensor for oxytetracycline assay with self-checking function by integrating photoelectrochemical (PEC) and electrochemical (EC) signal outputs in one analysis system. Zn-defective CdS/ZnS heterostructure was synthesized and served as the photo-electroactive substrate for constructing the biorecognition process, while methylene blue (MB) was used as a dual-functional probe to enhance both PEC and EC signals. Due to the high activity of Zn-defective CdS/ZnS heterojunction and the unique dual-modal signal readout strategy, the biosensing platform exhibits superior analytical performance with the relatively wide linear range (0.01-50 ng mL-1), lower detection limits of 1.86 pg mL-1 (PEC mode) and 3.08 pg mL-1 (EC mode), as well as good selectivity, stability and reproducibility. The proposed dual-model analytical system with self-checking function is envisioned to provide a new approach for sensitive and reliable biosensing.
Collapse
Affiliation(s)
- Pei Song
- Central Laboratory, Affiliated Jinhua Hospital, Zhejiang University School of Medicine, Jinhua, 321000, China; College of Geography and Environmental Sciences, College of Chemistry and Materials Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Ping Qu
- Zhejiang Jinhua Ecological and Environmental Monitoring Center, Jinhua, 321015, China
| | - Min Wang
- College of Geography and Environmental Sciences, College of Chemistry and Materials Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Ai-Jun Wang
- College of Geography and Environmental Sciences, College of Chemistry and Materials Sciences, Zhejiang Normal University, Jinhua, 321004, China
| | - Yadong Xue
- Central Laboratory, Affiliated Jinhua Hospital, Zhejiang University School of Medicine, Jinhua, 321000, China.
| | - Li-Ping Mei
- College of Geography and Environmental Sciences, College of Chemistry and Materials Sciences, Zhejiang Normal University, Jinhua, 321004, China.
| | - Jiu-Ju Feng
- College of Geography and Environmental Sciences, College of Chemistry and Materials Sciences, Zhejiang Normal University, Jinhua, 321004, China.
| |
Collapse
|
8
|
Ghalkhani M, Sadat Khaloo S, Sohouli E. Development of an electrochemical medetomidine nanosensor based on N and P-doped carbon nano-onions, MoS2, and poly (melamine) nanocomposite. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
|
9
|
Bakhshandeh F, Saha S, Sen P, Sakib S, MacLachlan R, Kanji F, Osman E, Soleymani L. A universal bacterial sensor created by integrating a light modulating aptamer complex with photoelectrochemical signal readout. Biosens Bioelectron 2023; 235:115359. [PMID: 37187062 DOI: 10.1016/j.bios.2023.115359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/05/2023] [Accepted: 04/26/2023] [Indexed: 05/17/2023]
Abstract
Photoelectrochemical (PEC) signal transduction is of great interest for ultrasensitive biosensing; however, signal-on PEC assays that do not require target labeling remain elusive. In this work, we developed a signal-on biosensor that uses nucleic acids to modulate PEC currents upon target capture. Target presence removes a biorecognition probe from a DNA duplex carrying a gold nanoparticle, bringing the gold nanoparticle in direct contact to the photoelectrode and increasing the PEC current. This assay was used to develop a universal bacterial detector by targeting peptidoglycan using an aptamer, demonstrating a limit-of-detection of 82 pg/mL (13 pM) in buffer and 239 pg/mL (37 pM) in urine for peptidoglycan and 1913 CFU/mL forEscherichia coliin urine. When challenged with a panel of unknown targets, the sensor identified samples with bacterial contamination versus fungi. The versatility of the assay was further demonstrated by analyzing DNA targets, which yielded a limit-of-detection of 372 fM.
Collapse
Affiliation(s)
- Fatemeh Bakhshandeh
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Sudip Saha
- School of Biomedical Engineering, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Payel Sen
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Sadman Sakib
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Roderick MacLachlan
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Farhaan Kanji
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Enas Osman
- School of Biomedical Engineering, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada
| | - Leyla Soleymani
- Department of Engineering Physics, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada; School of Biomedical Engineering, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada; Michael G. DeGroote Institute for Infectious Disease Research, 1280 Main Street West, L8S 4L8, Hamilton, Ontario, Canada.
| |
Collapse
|
10
|
Tang X, Wang H, Zhang X, Mao C, Wu L, Zhao L. A photoelectrochemical immunosensing platform for ultrasensitive detection of alpha-fetoprotein based on a signal amplification strategy. Bioelectrochemistry 2023; 150:108351. [PMID: 36525772 DOI: 10.1016/j.bioelechem.2022.108351] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 12/05/2022] [Accepted: 12/10/2022] [Indexed: 12/14/2022]
Abstract
For the first time, a PEC immunosensor based on a signal amplification strategy is successfully constructed to quantitatively detect alpha-fetoprotein in serum sample. Three favorable factors explain the ultra-high sensitivity of this method. Firstly, compared with pure BiPO4, the BiPO4/BiOBr heterojunction has a narrower band gap, which expands the light absorption range and enables the light energy to be fully utilized. Secondly, the separation of photogenerated electrons and hole pairs during PEC detection is due to the efficient matching of energy levels among BiPO4, BiOBr and CdS, inhibiting the recombination of photogenerated electrons, which improves the performance of PEC immunosensor. Thirdly, due to the presence of CdS, the light absorption capability of the sensor is enhanced, more electron-hole pairs are generated, and the photocurrent signal is increase. Under the optimal conditions, the PEC immunosensor shows a wide linear range of 0.001-1000 ng/mL for AFP and a low detection limit of 0.82 pg/mL. The PEC immunosensor developed in this experiment has excellent reproducibility, stability and high sensitivity, and also achieves satisfactory results in the analysis of human serum samples, establishing a new analytical method for biomarker detection.
Collapse
Affiliation(s)
- Ximing Tang
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China
| | - Haiwei Wang
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China
| | - Xinan Zhang
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China
| | - Chunling Mao
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China
| | - Lei Wu
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China
| | - Longshan Zhao
- School of Pharmacy, Shenyang Pharmaceutical University, 103 Wenhua Road Shenhe District, Shenyang, Liaoning, 110016, P. R. China.
| |
Collapse
|
11
|
Li YY, Ma XX, Song XY, Ma LL, Li YY, Meng X, Chen YJ, Xu KX, Moosavi-Movahedi AA, Xiao BL, Hong J. Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode. SENSORS (BASEL, SWITZERLAND) 2023; 23:3209. [PMID: 36991919 PMCID: PMC10051639 DOI: 10.3390/s23063209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/11/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
Glucose sensors based blood glucose detection are of great significance for the diagnosis and treatment of diabetes because diabetes has aroused wide concern in the world. In this study, bovine serum albumin (BSA) was used to cross-link glucose oxidase (GOD) on a glassy carbon electrode (GCE) modified by a composite of hydroxy fullerene (HFs) and multi-walled carbon nanotubes (MWCNTs) and protected with a glutaraldehyde (GLA)/Nafion (NF) composite membrane to prepare a novel glucose biosensor. The modified materials were analyzed by UV-visible spectroscopy (UV-vis), transmission electron microscopy (TEM), and cyclic voltammetry (CV). The prepared MWCNTs-HFs composite has excellent conductivity, the addition of BSA regulates MWCNTs-HFs hydrophobicity and biocompatibility, and better immobilizes GOD on MWCNTs-HFs. MWCNTs-BSA-HFs plays a synergistic role in the electrochemical response to glucose. The biosensor shows high sensitivity (167 μA·mM-1·cm-2), wide calibration range (0.01-3.5 mM), and low detection limit (17 μM). The apparent Michaelis-Menten constant Kmapp is 119 μM. Additionally, the proposed biosensor has good selectivity and excellent storage stability (120 days). The practicability of the biosensor was evaluated in real plasma samples, and the recovery rate was satisfactory.
Collapse
Affiliation(s)
- Yang-Yang Li
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin-Xin Ma
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin-Yan Song
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Lin-Lin Ma
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Yu-Ying Li
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Xin Meng
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Yu-Jie Chen
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Ke-Xin Xu
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | | | - Bao-Lin Xiao
- School of Life Sciences, Henan University, Kaifeng 475000, China
| | - Jun Hong
- School of Life Sciences, Henan University, Kaifeng 475000, China
| |
Collapse
|
12
|
Eco-Friendly Synthesis of Functionalized Carbon Nanodots from Cashew Nut Skin Waste for Bioimaging. Catalysts 2023. [DOI: 10.3390/catal13030547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2023] Open
Abstract
In this study, Anacardium occidentale (A. occidentale) nut skin waste (cashew nut skin waste) was used as a raw material to synthesize functionalized carbon nanodots (F-CNDs). A. occidentale biomass-derived F-CNDs were synthesized at a low temperature (200 °C) using a facile, economical hydrothermal method and subjected to XRD, FESEM, TEM, HRTEM, XPS, Raman Spectroscopy, ATR-FTIR, and Ultraviolet-visible (UV–vis) absorption and fluorescence spectroscopy to determine their structures, chemical compositions, and optical properties. The analysis revealed that dispersed, hydrophilic F-CNDs had a mean diameter of 2.5 nm. XPS and ATR-FTIR showed F-CNDs had a crystalline core and an amorphous surface decorated with –NH2, –COOH, and C=O. In addition, F-CNDs had a quantum yield of 15.5% and exhibited fluorescence with maximum emission at 406 nm when excited at 340 nm. Human colon cancer (HCT-116) cell assays showed that F-CNDs readily penetrated into the cells, had outstanding biocompatibility, high photostability, and minimal toxicity. An MTT assay showed that the viability of HCT-116 cells incubated for 24 h in the presence of F-CNDs (200 μg mL–1) exceeded 95%. Furthermore, when stimulated by filters of three different wavelengths (405, 488, and 555 nm) under a laser scanning confocal microscope, HCT-116 cells containing F-CNDs emitted blue, red, and green, respectively, which suggests F-CNDs might be useful in the biomedical field. Thus, we describe the production of a fluorescent nanoprobe from cashew nut waste potentially suitable for bioimaging applications.
Collapse
|
13
|
Huo GN, Zhang SS, Li YL, Li JX, Yue Z, Huang WP, Zhang SM, Zhu BL. CdS-Modified TiO 2 Nanotubes with Heterojunction Structure: A Photoelectrochemical Sensor for Glutathione. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 13:13. [PMID: 36615922 PMCID: PMC9824176 DOI: 10.3390/nano13010013] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 11/20/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
The formation of heterojunction structures can effectively prevent the recombination of photogenerated electron-hole pairs in semiconductors and result in the enhancement of photoelectric properties. Using TiO2 nanotubes (prepared using the hydrothermal-impregnation method) as carriers, CdS-TiO2NTs were fabricated as a photoelectrochemical (PEC) sensor, which can be used under visible light and can exhibit good PEC performance due to the existence of the heterojunction structure. The experimental results show that the prepared CdS-TiO2NTs electrode had a linear response to 2-16 mM glutathione (GSH). The sensor's sensitivity and detection limit (LOD) were 102.9 µA·mM-1 cm-2 and 27.7 µM, respectively. Moreover, the biosensor had good stability, indicating the potential application of this kind of heterojunction PEC biosensor.
Collapse
Affiliation(s)
- Guo-Na Huo
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
- Chemistry and Chemical Engineering College, Xingtai University, Xingtai 054000, China
| | - Sha-Sha Zhang
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
| | - Yue-Liu Li
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
| | - Jia-Xing Li
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
| | - Zhao Yue
- Department of Microelectronics, Nankai University, Tianjin 300350, China
| | - Wei-Ping Huang
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
| | - Shou-Min Zhang
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
| | - Bao-Lin Zhu
- College of Chemistry, The Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Tianjin Key Laboratory of Metal and Molecule-Based Material Chemistry, Nankai University, Tianjin 300071, China
- National Demonstration Center for Experimental Chemistry Education (Nankai University), Tianjin 300071, China
| |
Collapse
|
14
|
Photoelectrochemical biosensor based on FTO modified with BiVO4 film and gold nanoparticles for detection of miRNA-25 biomarker and single-base mismatch. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.117099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
15
|
Fan M, Zhu S, Zhang Q, Wang X, Zhang L, Chang Z, Chong R. Sensitive photoelectrochemical sensing of glucose using hematite decorated with NiAl-layered double hydroxides. Food Chem 2022; 405:134883. [DOI: 10.1016/j.foodchem.2022.134883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 09/30/2022] [Accepted: 11/03/2022] [Indexed: 11/11/2022]
|
16
|
Atchudan R, Perumal S, Jebakumar Immanuel Edison TN, Aldawood S, Vinodh R, Sundramoorthy AK, Ghodake G, Lee YR. Facile synthesis of novel molybdenum disulfide decorated banana peel porous carbon electrode for hydrogen evolution reaction. CHEMOSPHERE 2022; 307:135712. [PMID: 35843438 DOI: 10.1016/j.chemosphere.2022.135712] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/24/2022] [Accepted: 07/11/2022] [Indexed: 06/15/2023]
Abstract
Hydrogen is one of the cleanest renewable and environmentally friendly energy resource that can be generated through water splitting. However, hydrogen evolution occurs at high overpotential, and efficient hydrogen evolution catalysts are desired to replace state-of-the-art catalysts such as platinum. In the present work, a novel molybdenum disulfide decorated banana peel porous carbon (MoS2@BPPC) catalyst has been developed using banana peel carbon and molybdenum disulfide (MoS2) for hydrogen evolution reaction (HER). Banana peel porous carbon (BPPC) was initially synthesized from the banana peel (biowaste) by a simple carbonization method. Subsequently, 20 wt% of bare MoS2 was distributed on the pristine BPPC matrix using the dry-impregnation method. The resulting MoS2@BPPC composites were systematically investigated to determine the morphology and structure. Finally, using a three-electrode cell system, pristine BPPC, bare MoS2, and MoS2@BPPC composite were used as HER electrocatalysts. The developed MoS2@BPPC composite showed greater HER activity and possessed excellent stability in the acid solution, including an overpotential of 150 mV at a current density of -10 mA cm-2, and a Tafel slope of 51 mV dec-1. This Tafel study suggests that the HER takes place by Volmer-Heyrovsky mechanism with a rate-determining Heyrovsky step. The excellent electrochemical performance of MoS2@BPPC composite for HER can be ascribed to its unique porous nanoarchitecture. Further, due to the synergetic effect between MoS2 and porous carbon. The HER activity using the MoS2@BPPC electrode advises that the prepared catalyst may hold great promise for practical applications.
Collapse
Affiliation(s)
- Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea.
| | - Suguna Perumal
- Department of Chemistry, Sejong University, Seoul, 143-747, Republic of Korea
| | | | - S Aldawood
- Department of Physics and Astronomy, College of Science, P.O. BOX 2455, King Saud University, Riyadh, 11451, Saudi Arabia
| | - Rajangam Vinodh
- School of Electrical and Computer Engineering, Pusan National University, Busan, 46241, Republic of Korea
| | - Ashok K Sundramoorthy
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai, 600077, Tamil Nadu, India
| | - Gajanan Ghodake
- Department of Biological and Environmental Science, College of Life Science and Biotechnology, Dongguk University-Seoul, Ilsandong-gu, Goyang-si, 10326, Gyeonggi-do, Republic of Korea
| | - Yong Rok Lee
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea.
| |
Collapse
|
17
|
Atchudan R, Perumal S, Edison TNJI, Albasher G, Sundramoorthy AK, Vinodh R, Lee YR. Lotus-biowaste derived sulfur/nitrogen-codoped porous carbon as an eco-friendly electrocatalyst for clean energy harvesting. ENVIRONMENTAL RESEARCH 2022; 214:113910. [PMID: 35870499 DOI: 10.1016/j.envres.2022.113910] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/11/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
Recent research is focused on biomass-derived porous carbon materials for energy harvesting (hydrogen evolution reaction) because of their cost-effective synthesis, enriched with heteroatoms, lightweight, and stable properties. Here, the synthesis of porous carbon (PC) materials from lotus seedpod (LP) and lotus stem (LS) is reported by the pyrolysis method. The porous and graphitic structure of the prepared LP-PC and LS-PC materials were confirmed by field emission scanning electron microscopy, transmission electron microscopy with selected area electron diffraction, X-ray diffraction, and nitrogen adsorption-desorption measurements. Heteroatoms in LP-PC and LS-PC materials were investigated by attenuated total reflection-Fourier transform infrared and X-ray photoelectron spectroscopy. The specific surface area of LP-PC and LS-PC were calculated as 457 and 313 m2 g-1, respectively. Nitrogen and sulfur enriched LP-PC and LS-PC materials were found to be effective electrocatalysts for hydrogen evolution reactions. LP-PC catalyst showed a very low overpotential of 111 mV with the Tafel slope of 69 mV dec-1, and LS-PC catalyst achieved a Tafel slope of 85 mV dec-1 with a low overpotential of 135 mV. This work is expected to be extended for the development of biomass as a sustainable porous carbon electrocatalyst with a tunable structure, elements, and electronic properties. Furthermore, preparing carbon materials from the biowaste and applying clean energy harvesting might reduce environmental pollution.
Collapse
Affiliation(s)
- Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea
| | - Suguna Perumal
- Department of Chemistry, Sejong University, Seoul, 143747, Republic of Korea.
| | | | - Gadah Albasher
- Department of Zoology, College of Science, King Saud University, Riyadh, Saudi Arabia
| | - Ashok K Sundramoorthy
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai, 600077, Tamil Nadu, India
| | - Rajangam Vinodh
- School of Electrical and Computer Engineering, Pusan National University, Busan, 46241, Republic of Korea
| | - Yong Rok Lee
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea.
| |
Collapse
|
18
|
Mansoor A, Khurshid Z, Khan MT, Mansoor E, Butt FA, Jamal A, Palma PJ. Medical and Dental Applications of Titania Nanoparticles: An Overview. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:nano12203670. [PMID: 36296859 PMCID: PMC9611494 DOI: 10.3390/nano12203670] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/08/2022] [Accepted: 10/09/2022] [Indexed: 05/25/2023]
Abstract
Currently, titanium oxide (TiO2) nanoparticles are successfully employed in human food, drugs, cosmetics, advanced medicine, and dentistry because of their non-cytotoxic, non-allergic, and bio-compatible nature when used in direct close contact with the human body. These NPs are the most versatile oxides as a result of their acceptable chemical stability, lower cost, strong oxidation properties, high refractive index, and enhanced aesthetics. These NPs are fabricated by conventional (physical and chemical) methods and the latest biological methods (biological, green, and biological derivatives), with their advantages and disadvantages in this epoch. The significance of TiO2 NPs as a medical material includes drug delivery release, cancer therapy, orthopedic implants, biosensors, instruments, and devices, whereas their significance as a dental biomaterial involves dentifrices, oral antibacterial disinfectants, whitening agents, and adhesives. In addition, TiO2 NPs play an important role in orthodontics (wires and brackets), endodontics (sealers and obturating materials), maxillofacial surgeries (implants and bone plates), prosthodontics (veneers, crowns, bridges, and acrylic resin dentures), and restorative dentistry (GIC and composites).
Collapse
Affiliation(s)
- Afsheen Mansoor
- Department of Dental Material Sciences, School of Dentistry, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad 44080, Pakistan
| | - Zohaib Khurshid
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudi Arabia;
| | - Muhammad Talal Khan
- Department of Dental Biomaterials, Bakhtawar Amin Medical and Dental College, Multan 60650, Pakistan;
| | - Emaan Mansoor
- Islamic International Dental College, Riphah International University, Islamabad 44000, Pakistan;
| | - Faaz Ahmad Butt
- Department of Materials Engineering, NED University of Engineering & Technology, Karachi 74200, Pakistan;
| | - Asif Jamal
- Department of Microbiology, Quaid-i-Azam University, Islamabad 45320, Pakistan;
| | - Paulo J. Palma
- Center for Innovation and Research in Oral Sciences (CIROS), Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
- Institute of Endodontics, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
| |
Collapse
|
19
|
Arshad F, Mohd-Naim NF, Chandrawati R, Cozzolino D, Ahmed MU. Nanozyme-based sensors for detection of food biomarkers: a review. RSC Adv 2022; 12:26160-26175. [PMID: 36275095 PMCID: PMC9475342 DOI: 10.1039/d2ra04444g] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 09/07/2022] [Indexed: 11/21/2022] Open
Abstract
Nanozymes have piqued the curiosity of scientists in recent years because of their ability to demonstrate enzyme-like activity combined with advantages such as high stability, inexpensive availability, robust activity, and tunable properties. These attributes have allowed the successful application of nanozymes in sensing to detect various chemical and biological target analytes, overcoming the shortcomings of conventional detection techniques. In this review, we discuss recent developments of nanozyme-based sensors to detect biomarkers associated with food quality and safety. First, we present a brief introduction to this topic, followed by discussing the different types of sensors used in food biomarker detection. We then highlight recent studies on nanozyme-based sensors to detect food markers such as toxins, pathogens, antibiotics, growth hormones, metal ions, additives, small molecules, and drug residues. In the subsequent section, we discuss the challenges and possible solutions towards the development of nanozyme-based sensors for application in the food industry. Finally, we conclude the review by discussing future perspectives of this field towards successful detection and monitoring of food analytes.
Collapse
Affiliation(s)
- Fareeha Arshad
- Biosensors and Nanobiotechnology Laboratory, Faculty of Science, Universiti Brunei Darussalam Integrated Science Building Jalan Tungku Link Gadong BE 1410 Brunei Darussalam
| | - Noor Faizah Mohd-Naim
- Biosensors and Nanobiotechnology Laboratory, Faculty of Science, Universiti Brunei Darussalam Integrated Science Building Jalan Tungku Link Gadong BE 1410 Brunei Darussalam
- PAPRSB Institute of Health Science, Universiti Brunei Darussalam Gadong Brunei Darussalam
| | - Rona Chandrawati
- School of Chemical Engineering, University of New South Wales (UNSW Sydney) Sydney NSW 2052 Australia
| | - Daniel Cozzolino
- Centre for Nutrition and Food Sciences, The University of Queensland Australia
| | - Minhaz Uddin Ahmed
- Biosensors and Nanobiotechnology Laboratory, Faculty of Science, Universiti Brunei Darussalam Integrated Science Building Jalan Tungku Link Gadong BE 1410 Brunei Darussalam
| |
Collapse
|
20
|
Green Synthesis of Multicolor Emissive Nitrogen-Doped Carbon Dots for Bioimaging of Human Cancer Cells. J CLUST SCI 2022. [DOI: 10.1007/s10876-022-02337-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
21
|
Yang H, Cao G, Huang Y, Lin Y, Zheng F, Lin L, Liu F, Li S. Nitrogen-doped carbon@TiO 2 double-shelled hollow spheres as an electrochemical sensor for simultaneous determination of dopamine and paracetamol in human serum and saliva. J Pharm Anal 2022; 12:436-445. [PMID: 35811619 PMCID: PMC9257442 DOI: 10.1016/j.jpha.2021.08.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 08/21/2021] [Accepted: 08/30/2021] [Indexed: 11/17/2022] Open
Abstract
As the most commonly used antipyretic and analgesic drug, paracetamol (PA) coexists with neurotransmitter dopamine (DA) in real biological samples. Their simultaneous determination is extremely important for human health, but they also interfere with each other. In order to improve the conductivity, adsorption affinity, sensitivity, and selectivity of TiO2-based electrochemical sensor, N-doped carbon@TiO2 double-shelled hollow sphere (H-C/N@TiO2) is designed and synthesized by simple alcoholic and hydrothermal method, using polystyrene sphere (PS) as a template. Meanwhile, TiO2 hollow spheres (H-TiO2) or N-doped carbon hollow spheres (H-C/N) are also prepared by the same method. H-C/N@TiO2 has good conductivity, charge separation, and the highly enhanced and stable current responses for the detection of PA and DA. The detection limit and linear range are 50.0 nmol/L and 0.3-50 μmol/L for PA, 40.0 nmol/L and 0.3-50 μmol/L for DA, respectively, which are better than those of carbon-based sensors. Moreover, this electrochemical sensor, with high selectivity, strong anti-interference, high reliability, and long time durability, can be used for the simultaneous detection of PA and DA in human blood serum and saliva. The high electrochemical performance of H-C/N@TiO2 is attributed to the multi-functional combination of different layers, because of good conductivity, absorption and electrons transfer ability from in-situ N-doped carbon and electrocatalytic activity from TiO2.
Collapse
Affiliation(s)
- Hui Yang
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
| | - Gongxun Cao
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
| | - Yongjun Huang
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
| | - Ye Lin
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
| | - Fengying Zheng
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
| | - Luxiu Lin
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Provincial Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Key Laboratory of Separation and Analysis Science and Technology, Zhangzhou, Fujian, 363000, China
| | - Fengjiao Liu
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Provincial Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Key Laboratory of Separation and Analysis Science and Technology, Zhangzhou, Fujian, 363000, China
| | - Shunxing Li
- College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Provincial Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou, Fujian, 363000, China
- Fujian Key Laboratory of Separation and Analysis Science and Technology, Zhangzhou, Fujian, 363000, China
| |
Collapse
|
22
|
Multifunctional Core-Shell NiFe2O4 Shield with TiO2/rGO Nanostructures for Biomedical and Environmental Applications. Bioinorg Chem Appl 2022; 2022:4805490. [PMID: 35686291 PMCID: PMC9174006 DOI: 10.1155/2022/4805490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 04/07/2022] [Accepted: 05/05/2022] [Indexed: 11/17/2022] Open
Abstract
Multifunctional core@shell nanoparticles have been synthesized in this paper through 3 stages: NiFe2O4 nanoparticles by microwave irradiation using Pedalium murex leaf extract as a fuel, core@shell NiFe2O4@TiO2 nanoparticles by sol-gel, and NiFe2O4@TiO2@rGO by sol-gel using preprepared reduced graphene oxide obtained by modified Hummer’s method. XRD analysis confirmed the presence of both cubic NiFe2O4 spinel and tetragonal TiO2 rutile phases, while Raman spectroscopy analysis displays both D and G bands (ID/IG = 1.04) associated with rGO. Morphological observations by HRTEM reveal a core-shell nanostructure formed by NiFe2O4 core as confirmed by SAED with subsequent thin layers of TiO2 and rGO. Magnetic measurements show a ferromagnetic behavior, where the saturation magnetization drops drastically from 45 emu/g for NiFe2O4 to 15 emu/g after TiO2 and rGO nonmagnetic bilayers coating. The as-fabricated multifunctional core@shell nanostructures demonstrate tunable self-heating characteristics: rise of temperature and specific absorption rate in the range of ΔT = 3–10°C and SAR = 3–58 W/g, respectively. This effectiveness is much close to the threshold temperature of hyperthermia (45°C), and the zones of inhibition show the better effective antibacterial activity of NTG against various Gram-positive and Gram-negative bacterial strains besides simultaneous good efficient, stable, and removable sonophotocatalyst toward the TC degradation.
Collapse
|
23
|
Sahare P, Alvarez PG, Yanez JMS, Bárcenas JGL, Chakraborty S, Paul S, Estevez M. Engineered titania nanomaterials in advanced clinical applications. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2022; 13:201-218. [PMID: 35223351 PMCID: PMC8848344 DOI: 10.3762/bjnano.13.15] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 02/03/2022] [Indexed: 06/06/2023]
Abstract
Significant advancement in the field of nanotechnology has raised the possibility of applying potent engineered biocompatible nanomaterials within biological systems for theranostic purposes. Titanium dioxide (titanium(IV) oxide/titania/TiO2) has garnered considerable attention as one of the most extensively studied metal oxides in clinical applications. Owing to the unique properties of titania, such as photocatalytic activity, excellent biocompatibility, corrosion resistance, and low toxicity, titania nanomaterials have revolutionized therapeutic approaches. Additionally, titania provides an exceptional choice for developing innovative medical devices and the integration of functional moieties that can modulate the biological responses. Thus, the current review aims to present a comprehensive and up-to-date overview of TiO2-based nanotherapeutics and the corresponding future challenges.
Collapse
Affiliation(s)
- Padmavati Sahare
- Centre of Applied Physics and Advanced Technologies (CFATA), National Autonomous University of Mexico, Queretaro, Mexico
| | - Paulina Govea Alvarez
- Centre of Applied Physics and Advanced Technologies (CFATA), National Autonomous University of Mexico, Queretaro, Mexico
| | - Juan Manual Sanchez Yanez
- Instituto de Investigaciones Químico Biológicas, Universidad Michoacana de San Nicolas de Hidalgo, Morelia, Mexico
| | | | - Samik Chakraborty
- Division of Nephrology, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Sujay Paul
- Tecnologico de Monterrey, School of Engineering and Sciences, Campus Queretaro, Av. Epigmenio Gonzalez, No. 500 Fracc. San Pablo, CP 76130 Querétaro, Mexico
| | - Miriam Estevez
- Centre of Applied Physics and Advanced Technologies (CFATA), National Autonomous University of Mexico, Queretaro, Mexico
| |
Collapse
|
24
|
Mao X, Zhang C. A microfluidic cloth-based photoelectrochemical analytical device for the detection of glucose in saliva. Talanta 2022; 238:123052. [PMID: 34808571 DOI: 10.1016/j.talanta.2021.123052] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 10/18/2021] [Accepted: 11/07/2021] [Indexed: 02/08/2023]
Abstract
Photoelectrochemical (PEC) detection is a widely used detection method that uses light to stimulate and photocurrent signals to detect the target. Due to the disengagement of the excitation unit and the detection unit, the PEC background signal is reduced, and the detection sensitivity is improved. In this work, we report the first demonstration of PEC detection for microfluidic cloth-based analytical devices (μCADs). Using PEC μCADs integrated with cadmium sulfide quantum dots (CdS QDs) and multiwalled carbon nanotubes (MWCNTs), the nonenzymatic, sensitive and rapid measurement of glucose in saliva has been achieved. For the cloth-based device, the PEC reaction zone and cloth-based electrodes can be fabricated by inexpensive wax-based and carbon ink-based screen-printing, respectively. By the layer-by-layer method, the as-prepared poly (dimethyl diadly ammonium chloride-functionalized) MWCNTs (PDDA-MWCNTs) and CdS QDs are successively adsorbed onto the working electrode surface of the cloth-based device. In the presence of an excitation source and glucose, the CdS QDs generate a strong oxidizing electron hole that can then continuously oxidize glucose to produce an electrical signal for glucose detection. Under optimized conditions, a linear dependence is obtained between the PEC signal and glucose concentrations in the range of 0.05-1000 μM with a detection limit of 15.99 nM. In the detection range, the cloth-based device also shows acceptable selectivity, reproducibility, and long-term stability. Moreover, the method has been implemented for the detection of glucose in real saliva samples, suggesting good potential for biochemical applications.
Collapse
Affiliation(s)
- Xinyuan Mao
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China
| | - Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China.
| |
Collapse
|
25
|
Atchudan R, Edison TNJI, Perumal S, Vinodh R, Sundramoorthy AK, Babu RS, Lee YR. Morus nigra-derived hydrophilic carbon dots for the highly selective and sensitive detection of ferric ion in aqueous media and human colon cancer cell imaging. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2021.128073] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
26
|
Atchudan R, Jebakumar Immanuel Edison TN, Perumal S, Vinodh R, Babu RS, Sundramoorthy AK, Renita AA, Lee YR. Facile synthesis of nitrogen-doped porous carbon materials using waste biomass for energy storage applications. CHEMOSPHERE 2022; 289:133225. [PMID: 34896173 DOI: 10.1016/j.chemosphere.2021.133225] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 12/01/2021] [Accepted: 12/06/2021] [Indexed: 06/14/2023]
Abstract
A simple, low-cost, and green route for the preparation of lotus carbon (LC) materials using lotus parts including leaves, flowers, fruits (seed pods), and stems as a renewable precursor is reported. Different porous carbons, leaf-carbon (LF-carbon), flower-carbon (FL-carbon), fruit-carbon (FR-carbon), and stem-carbon (ST-carbon) were synthesized from different parts of the lotus plant by simple carbonization method. The as-synthesized LC materials were well-characterized by many techniques such as electron microscopy and spectroscopy techniques, X-ray diffraction, and BET-surface area analysis. These techniques confirmed the porous structure of LC materials and the existence of heteroatoms in the prepared LC materials. The mesoporous structure of LC materials suggested employing it for the supercapacitor applications. The obtained FR-Carbon exhibits a high specific capacitance of 160 F/g in a three-electrode system in an aqueous 1 M H2SO4 electrolyte with a high rate performance of 52% retention from 0.5 to 5.0 A/g with good cycling stability of 95%. These results indicate that the porous carbon derived from lotus fruits is a potential electrode material for high-performance supercapacitors.
Collapse
Affiliation(s)
- Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea.
| | | | - Suguna Perumal
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea
| | - Rajangam Vinodh
- School of Electrical and Computer Engineering, Pusan National University, Busan, 46241, Republic of Korea
| | - Rajendran Suresh Babu
- Laboratory of Experimental and Applied Physics, Centro Federal de Educação Tecnológica, Celso Suckow da Fonseca (CEFET/RJ), Av. Maracanã 229, Rio de Janeiro, 20271-110, Brazil
| | - Ashok K Sundramoorthy
- Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical And Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai, 600077, Tamil Nadu, India
| | - A Annam Renita
- Department of Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India
| | - Yong Rok Lee
- School of Chemical Engineering, Yeungnam University, Gyeongsan, 38541, Republic of Korea.
| |
Collapse
|
27
|
Wang C, Huang J, Li J, Cao L, Wang H, Kajiyoshi K. Regulating positions of TiO2 on TiO2/biomass carbon composite surface to enhance conversion abilities of polysulfides. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.115888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
N, O-codoped hierarchical porous graphitic carbon for electrochemical immunosensing of Lactobacillus rhamnosus GG. Mikrochim Acta 2021; 189:5. [PMID: 34855013 DOI: 10.1007/s00604-021-05049-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 10/04/2021] [Indexed: 12/17/2022]
Abstract
An ultrasensitive label-free electrochemical immunosensor was fabricated for quantitative detection of Lactobacillus rhamnosus GG (LGG). The N/O co-doped three-dimensional hierarchical porous graphitic (THPG) carbon was synthesized by a one-step synthesis of polyaniline hydrogel, and followed by simple carbonization and chemical activation procedures. Because of the unique structure design, the obtained THPG carbon networks possess an ultra-large specific surface area of 4859 m2 g-1 along with a class of highly graphitic carbons. The results offer an enormous surface area and excellent electrical conductivity for label-free electrochemical immunosensing of probiotic L. rhamnosus strain. Under optimal conditions, the immunosensor showed a good linear relationship between peak current and concentration of LGG (R2 = 0.9976), with a detection limit of 2 CFU mL-1. Furthermore, this label-free immunosensor also shows good specificity, long-term stability, and reliability, and could be applied to detect probiotic LGG in dairy products and drinks with satisfactory results. The present protocol was shown to be quite promising for practical screening and functional evaluation of probiotic products containing LGG. A ultrasensitive label-free electrochemical immunosensor based on THPG carbon was fabricated for detection of Lactobacillus rhamnosus GG.
Collapse
|
29
|
Ji W, Tang X, Du W, Lu Y, Wang N, Wu Q, Wei W, Liu J, Yu H, Ma B, Li L, Huang W. Optical/electrochemical methods for detecting mitochondrial energy metabolism. Chem Soc Rev 2021; 51:71-127. [PMID: 34792041 DOI: 10.1039/d0cs01610a] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This review highlights the biological importance of mitochondrial energy metabolism and the applications of multiple optical/electrochemical approaches to determine energy metabolites. Mitochondria, the main sites of oxidative phosphorylation and adenosine triphosphate (ATP) biosynthesis, provide the majority of energy required by aerobic cells for maintaining their physiological activity. They also participate in cell growth, differentiation, information transmission, and apoptosis. Multiple mitochondrial diseases, caused by internal or external factors, including oxidative stress, intense fluctuations of the ionic concentration, abnormal oxidative phosphorylation, changes in electron transport chain complex enzymes and mutations in mitochondrial DNA, can occur during mitochondrial energy metabolism. Therefore, developing accurate, sensitive, and specific methods for the in vivo and in vitro detection of mitochondrial energy metabolites is of great importance. In this review, we summarise the mitochondrial structure, functions, and crucial energy metabolic signalling pathways. The mechanism and applications of different optical/electrochemical methods are thoroughly reviewed. Finally, future research directions and challenges are proposed.
Collapse
Affiliation(s)
- Wenhui Ji
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Xiao Tang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Wei Du
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Yao Lu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Nanxiang Wang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Qiong Wu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Wei Wei
- Department of General Surgery, Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research & The Affiliated Cancer Hospital of Nanjing Medical University, Nanjing 210009, China
| | - Jie Liu
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China.
| | - Haidong Yu
- Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China
| | - Bo Ma
- School of Pharmaceutical Sciences, Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211800, China
| | - Lin Li
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China. .,Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.,The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, China
| | - Wei Huang
- Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), Nanjing 211816, China. .,Frontiers Science Center for Flexible Electronics, Xi'an Institute of Flexible Electronics (IFE) and Xi'an Institute of Biomedical Materials & Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an 710072, China.,The Institute of Flexible Electronics (IFE, Future Technologies), Xiamen University, Xiamen 361005, China
| |
Collapse
|
30
|
Hao N, Zuo Y, Dai Z, Xiong M, Wei J, Qian J, Wang K. High-Throughput Detection of Multiple Contaminants Based on Portable Photoelectrochromic Sensor Chip. Anal Chem 2021; 93:14053-14058. [PMID: 34645270 DOI: 10.1021/acs.analchem.1c03868] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
With the increasing concerns about the environment and food safety, it is necessary to develop portable, low-cost, and high-throughput biosensors for the simultaneous detection of multiple contaminates. However, traditional photoelectrochemical (PEC) biosensors lack the ability of multiplexed assays due to the inherent mechanism limitation. Also, specialized instruments are necessary for most PEC biosensors. In this work, a portable high-throughput sensor chip has been successfully developed. By introducing electrochromic materials, the detection is based on color change instead of electric signals, which reduces the limitation of instruments. This designed sensor chip is composed of three parallel sensing channels fabricated by laser etching. Each channel is modified with TiO2/3D-g-C3N4 composites with excellent PEC activity and electrochromic material Prussian blue (PB). Under light illumination, photoinduced electrons generated by TiO2/3D-g-C3N4 are injected into PB, and blue PB is reduced to colorless Prussian white. Three organic contaminates, ochratoxin A, lincomycin, and edifenphos, can be simultaneously detected because the binding of these molecules with aptamers affects the electron transfer and the corresponding color changes. This portable and high-throughput sensor chip provides a convenient choice for multiplexed assays with good sensitivity and accuracy.
Collapse
Affiliation(s)
- Nan Hao
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Yanli Zuo
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Zhen Dai
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Meng Xiong
- School of Biotechnology, Jiangsu University of Science and Technology, Zhenjiang 212018, P. R. China
| | - Jie Wei
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Jing Qian
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| | - Kun Wang
- School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, P. R. China
| |
Collapse
|
31
|
Fedorenko V, Damberga D, Grundsteins K, Ramanavicius A, Ramanavicius S, Coy E, Iatsunskyi I, Viter R. Application of Polydopamine Functionalized Zinc Oxide for Glucose Biosensor Design. Polymers (Basel) 2021; 13:2918. [PMID: 34502958 PMCID: PMC8433701 DOI: 10.3390/polym13172918] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 12/29/2022] Open
Abstract
Zinc oxide (ZnO) nanostructures are widely used in optical sensors and biosensors. Functionalization of these nanostructures with polymers enables optical properties of ZnO to be tailored. Polydopamine (PDA) is a highly biocompatible polymer, which can be used as a versatile coating suitable for application in sensor and biosensor design. In this research, we have grown ZnO-based nanorods on the surface of ITO-modified glass-plated optically transparent electrodes (glass/ITO). Then the deposition of the PDA polymer layer on the surface of ZnO nanorods was performed from an aqueous PDA solution in such a way glass/ITO/ZnO-PDA structure was formed. The ZnO-PDA composite was characterized by SEM, TEM, and FTIR spectroscopy. Then glucose oxidase (GOx) was immobilized using crosslinking by glutaraldehyde on the surface of the ZnO-PDA composite, and glass/ITO/ZnO-PDA/GOx-based biosensing structure was designed. This structure was applied for the photo-electrochemical determination of glucose (Glc) in aqueous solutions. Photo-electrochemical determination of glucose by cyclic voltammetry and amperometry has been performed by glass/ITO/ZnO-PDA/GOx-based biosensor. Here reported modification/functionalization of ZnO nanorods with PDA enhances the photo-electrochemical performance of ZnO nanorods, which is well suited for the design of photo-electrochemical sensors and biosensors.
Collapse
Affiliation(s)
- Viktoriia Fedorenko
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas 3, LV-1004 Riga, Latvia; (V.F.); (D.D.); (K.G.); (A.R.)
| | - Daina Damberga
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas 3, LV-1004 Riga, Latvia; (V.F.); (D.D.); (K.G.); (A.R.)
| | - Karlis Grundsteins
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas 3, LV-1004 Riga, Latvia; (V.F.); (D.D.); (K.G.); (A.R.)
| | - Arunas Ramanavicius
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas 3, LV-1004 Riga, Latvia; (V.F.); (D.D.); (K.G.); (A.R.)
- Institute of Chemistry, Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania;
| | - Simonas Ramanavicius
- Institute of Chemistry, Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko Str. 24, LT-03225 Vilnius, Lithuania;
| | - Emerson Coy
- NanoBioMedical Centre, Adam Mickiewicz University in Poznan, Wszechnicy Piastowskiej Str. 3, 61-614 Poznan, Poland; (E.C.); (I.I.)
| | - Igor Iatsunskyi
- NanoBioMedical Centre, Adam Mickiewicz University in Poznan, Wszechnicy Piastowskiej Str. 3, 61-614 Poznan, Poland; (E.C.); (I.I.)
| | - Roman Viter
- Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas 3, LV-1004 Riga, Latvia; (V.F.); (D.D.); (K.G.); (A.R.)
- Center for Collective Use of Scientific Equipment, Sumy State University, 31, Sanatornaya Str., 40000 Sumy, Ukraine
| |
Collapse
|
32
|
Li H, Li Y, Zhang X, Liu P, He M, Li C, Wang Y. Near-infrared photoactive Yb-MOF functionalized with a large conjugate ionic liquid: synthesis and application for photoelectrochemical immunosensing of carcinoma embryonic antigen. NANOSCALE 2021; 13:9757-9765. [PMID: 34023865 DOI: 10.1039/d1nr01606g] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A novel near-infrared (NIR)-excited photoelectrochemical (PEC) immunosensor based on an ionic liquid functionalized metal organic framework (Yb-MOF) and gold nanoparticles (Au-NPs) was designed for the high-performance determination of carcinoembryonic antigen (CEA). The Yb-MOF was synthesized from the coordination of the Yb3+ metal ion with the 1,1'-(1,5-dihydropyrene-2,7-diyl)bis(3-(4-carboxybenzyl)-1H-imidazol-3-ium) bromide [DDPDBCBIm(Br)2] ionic liquid by a hydrothermal method. To improve the photoelectric conversion efficiency of the Yb-MOF in the NIR region, the surface of the Yb-MOF was integrated with gold nanoparticles (AuNPs) to fabricate a Yb-MOF@AuNP nanocomposite through an in situ reduction of chloroauric acid with sodium borohydride. The NIR photoelectrochemical response of the Yb-MOF@AuNPs at 808 nm was enhanced 4-fold over the pristine Yb-MOF. Subsequently, a photoelectrochemical platform based on the Yb-MOF@AuNPs was constructed for loading the CEA antibody (anti-CEA). After cross-linking with glutaraldehyde followed by blocking with bovine serum albumin, a photoelectrochemical sensor for assaying CEA was fabricated. Upon specifically interacting with CEA, CEA can block the photogenerated electron-hole pair transfer and the mass transfer of ascorbic acid to the sensing interface, thus leading to a decrease in photocurrent response. The photocurrent variation can be used for determining CEA quantitatively. After optimizing the experimental conditions, the photocurrent variations before and after incubation with CEA were linearly correlated with the CEA concentration over the range of 0.005-15 ng mL-1. The detection limit of CEA was calculated to be 0.25 pg mL-1 (S/N = 3). The immunosensor was employed for the measurement of free CEA in clinical serum samples, and the results were very consistent with the values obtained by clinical tests. The NIR PEC immunosensor also demonstrated excellent accuracy and recovery, which corroborates its potential as a practical technique in clinical diagnosis.
Collapse
Affiliation(s)
- Huiyue Li
- Key Laboratory of Catalysis and Energy Materials Chemistry of Ministry of Education & Hubei Key Laboratory of Catalysis and Materials Science & Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, South-Central University for Nationalities, Wuhan 430074, China.
| | | | | | | | | | | | | |
Collapse
|
33
|
Biowaste-originated heteroatom-doped porous carbonaceous material for electrochemical energy storage application. J IND ENG CHEM 2021. [DOI: 10.1016/j.jiec.2021.03.037] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
34
|
Avelino KYPS, Oliveira LS, Lucena-Silva N, Andrade CAS, Oliveira MDL. Flexible sensor based on conducting polymer and gold nanoparticles for electrochemical screening of HPV families in cervical specimens. Talanta 2021; 226:122118. [PMID: 33676673 DOI: 10.1016/j.talanta.2021.122118] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/10/2021] [Accepted: 01/11/2021] [Indexed: 12/17/2022]
Abstract
Considering the low sensitivity of cytological exams and high costs of the molecular methods, the development of diagnostic tests for effective diagnosis of HPV infections is a priority. In this work, biosensor composed of polypyrrole (PPy) films and gold nanoparticles (AuNPs) was obtained for specific detection of HPV genotypes. The biosensor was developed by using flexible electrodes based on polyethylene terephthalate (PET) strips coated with indium tin oxide (ITO). Polymeric films and AuNPs were obtained by electrosynthesis. Oligonucleotides sequences modified with functional amino groups were designed to recognize HPV gene families strictly. The modified oligonucleotides were chemically immobilized on the nanostructured platform. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the analysis of the electrode modification and monitoring of molecular hybridization. Electrochemical changes were observed after exposure of the biosensors to plasmid samples and cervical specimens. The biosensor based on the BSH16 probe showed a linear concentration range for target HPV16 gene detection of 100 pg μL-1 to 1 fg μL-1. A limit of detection (LOD) of 0.89 pg μL-1 and limit of quantification (LOQ) of 2.70 pg μL-1 were obtained, with a regression coefficient of 0.98. Screening tests on cervical specimens were performed to evaluate the sensibility and specificity for HPV and its viral family. The expression of a biomarker for tumorigenesis (p53 gene) was also monitored. In this work, a flexible system has been successfully developed for label-free detection of HPV families and p53 gene monitoring with high specificity, selectivity, and sensitivity.
Collapse
Affiliation(s)
- Karen Y P S Avelino
- Programa de Pós-Graduação Em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Léony S Oliveira
- Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Norma Lucena-Silva
- Instituto Aggeu Magalhães, Fundação Oswaldo Cruz (Fiocruz), 50670-420, Recife, PE, Brazil; Laboratório de Biologia Molecular, Departamento de Oncologia Pediátrica, Instituto de Medicina Integral Professor Fernando Figueira (IMIP), 50070-550, Recife, PE, Brazil
| | - César A S Andrade
- Programa de Pós-Graduação Em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil
| | - Maria D L Oliveira
- Programa de Pós-Graduação Em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901, Recife, PE, Brazil.
| |
Collapse
|
35
|
Perumal S, Atchudan R, Edison TNJI, Shim JJ, Lee YR. Exfoliation and Noncovalent Functionalization of Graphene Surface with Poly- N-Vinyl-2-Pyrrolidone by In Situ Polymerization. Molecules 2021; 26:molecules26061534. [PMID: 33799693 PMCID: PMC7999643 DOI: 10.3390/molecules26061534] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/04/2021] [Accepted: 03/09/2021] [Indexed: 11/16/2022] Open
Abstract
Heteroatom functionalization on a graphene surface can endow the physical and structural properties of graphene. Here, a one-step in situ polymerization method was used for the noncovalent functionalization of a graphene surface with poly-N-vinyl-2-pyrrolidone (PNVP) and the exfoliation of graphite into graphene sheets. The obtained graphene/poly-N-vinyl pyrrolidone (GPNVP) composite was thoroughly characterized. The surface morphology of GPNVP was observed using field emission scanning electron microscopy and high-resolution transmission electron microscopy. Raman spectroscopy and X-ray diffraction studies were carried out to check for the exfoliation of graphite into graphene sheets. Thermogravimetric analysis was performed to calculate the amount of PNVP on the graphene surface in the GPNVP composite. The successful formation of the GPNVP composite and functionalization of the graphene surface was confirmed by various studies. The cyclic voltammetry measurement at different scan rates (5–500 mV/s) and electrochemical impedance spectroscopy study of the GPNVP composite were performed in the typical three-electrode system. The GPNVP composite has excellent rate capability with the capacitive property. This study demonstrates the one-pot preparation of exfoliation and functionalization of a graphene surface with the heterocyclic polymer PNVP; the resulting GPNVP composite will be an ideal candidate for various electrochemical applications.
Collapse
|
36
|
Yola ML, Atar N, Özcan N. A novel electrochemical lung cancer biomarker cytokeratin 19 fragment antigen 21-1 immunosensor based on Si 3N 4/MoS 2 incorporated MWCNTs and core-shell type magnetic nanoparticles. NANOSCALE 2021; 13:4660-4669. [PMID: 33620353 DOI: 10.1039/d1nr00244a] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Lung cancer is one of deadliest and most life threatening cancer types. Cytokeratin 19 fragment antigen 21-1 (CYFRA 21-1) is a significant biomarker for the diagnosis of non-small cell lung cancer (NSCLC). Due to these reasons, a novel electrochemical immunosensor based on a silicon nitride (Si3N4)-molybdenum disulfide (MoS2) composite on multi-walled carbon nanotubes (Si3N4/MoS2-MWCNTs) as an electrochemical sensor platform and core-shell type magnetic mesoporous silica nanoparticles@gold nanoparticles (MMSNs@AuNPs) as a signal amplifier was presented for CYFRA21-1 detection in this study. Capture antibody (Ab1) immobilization on a Si3N4/MoS2-MWCNT modified glassy carbon electrode (Si3N4/MoS2-MWCNTs/GCE) was firstly successfully performed by stable electrostatic/ionic interactions between the -NH2 groups of the capture antibody and the polar groups of Si3N4/MoS2. Then, specific antibody-antigen interactions between the electrochemical sensor platform and the signal amplifier formed a novel voltammetric CYFRA21-1 immunosensor. The prepared composite materials and electrochemical sensor surfaces were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). A linearity range of 0.01-1.0 pg mL-1 and a low detection limit (LOD) of 2.00 fg mL-1 were also obtained for analytical applications. Thus, the proposed immunosensor based on Si3N4/MoS2-MWCNTs and MMSNs@AuNPs has great potential for medical diagnosis of lung cancer.
Collapse
Affiliation(s)
- Mehmet Lütfi Yola
- Hasan Kalyoncu University, Faculty of Health Sciences, Department of Nutrition and Dietetics, Gaziantep, Turkey.
| | - Necip Atar
- Pamukkale University, Faculty of Engineering, Department of Chemical Engineering, Denizli, Turkey
| | - Nermin Özcan
- Iskenderun Technical University, Faculty of Engineering and Natural Sciences, Department of Biomedical Engineering, Hatay, Turkey
| |
Collapse
|
37
|
A photoelectrochemical enzyme biosensor based on functionalized hematite microcubes for rutin determination by square-wave voltammetry. Mikrochim Acta 2021; 188:28. [PMID: 33404780 DOI: 10.1007/s00604-020-04659-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 11/19/2020] [Indexed: 10/22/2022]
Abstract
A photoelectrochemical biosensing strategy for the highly sensitive detection of the flavonoid rutin was developed by synergizing the photoelectrocatalytic properties of hematite (α-Fe2O3) decorated with palladium nanoparticles (PdNPs) and the biocatalysis towards laccase-based reactions. The integration of α-Fe2O3.PdNPs with a polyphenol oxidase as a biorecognition element yields a novel biosensing platform. Under visible light irradiation, the photoactive biocomposite can generate a stable photocurrent, which was found to be directly dependent upon the concentration of rutin. Under the optimal experimental conditions, the cathodic photocurrent, measured at 0.33 V vs. Ag/AgCl, from the square-wave voltammograms presented a linear dependence on the rutin concentration within the range of 0.008-30.0 × 10-8 mol L-1 (sensitivity: 1.7 μA·(× 10-8 M-1)·cm-2), with an experimental detection limit (S/N = 3) of 8.4 × 10-11 mol L-1. The proposed biosensor device presented good selectivity towards rutin in the presence of various organic compounds and inorganic ions, demonstrating the potential application of this biosensing platform in complex matrices. This bioanalytical device also exhibited excellent operational and analytical properties, such as intra-day (standard deviation, SD = 0.21%) and inter-day (SD = 1.30%) repeatability, and long storage stability (SD = 2.80% over 30 days).Graphical abstract.
Collapse
|
38
|
Using Diaper Waste to Prepare Magnetic Catalyst for the Synthesis of Glycerol Carbonate. INT J POLYM SCI 2020. [DOI: 10.1155/2020/9403714] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Diaper waste was calcined above 400°C after impregnated in the solution of nickel nitrate. The as-prepared diaper waste-derived materials were used as magnetic catalysts for the synthesis of glycerol carbonate (GC). Structure and catalytic ability investigations on the catalysts calcined at different temperatures indicated that calcination temperature was an important factor affecting the property of catalysts. It was found that the catalyst obtained at the calcination temperature of 700°C (named DW-Ni-700) showed the best performance. When DW-Ni-700 was used in the synthesis of GC, GC yield reached 93.2%, and the magnetic property of DW-Ni-700 facilitated the catalyst separation process. Meanwhile, DW-Ni-700 showed high reusability in the reaction. After four times reuse of DW-Ni-700, GC yield decreased less than 4%.
Collapse
|
39
|
Ghanbari MH, Norouzi Z. A new nanostructure consisting of nitrogen-doped carbon nanoonions for an electrochemical sensor to the determination of doxorubicin. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105098] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
40
|
Nitrogen-doped graphene quantum dot-based sensing platform for metabolite detection. Mikrochim Acta 2020; 187:532. [PMID: 32864710 DOI: 10.1007/s00604-020-04484-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Accepted: 08/05/2020] [Indexed: 01/02/2023]
Abstract
A novel fluorescent sensing platform based on nitrogen-doped graphene quantum dots (N-GQDs) is presented, which is able to detect various metabolites (cholesterol, glucose, lactate, and xanthine) rapidly, sensitively, and selectively. Hg2+ can attach on the surface of N-GQDs, leading to the quenching of N-GQD fluorescence. In the presence of cysteine (Cys), Hg2+ is released from N-GQDs and associates with Cys. Then, the fluorescence of N-GQDs is recovered. Hydrogen peroxide, resulting from the enzymatic oxidation of metabolites, can convert two molecules of Cys into one molecule of cystine, which cannot bind with Hg2+. So, the fluorescence of N-GQDs quenched again. For cholesterol, glucose, lactate, and xanthine, the limits of detection are 0.035 μmol/L, 0.025 μmol/L, 0.07 μmol/L, and 0.04 μmol/L, respectively, and the linear ranges are 1-12 μmol/L, 0.06-3 μmol/L, 0.2-70 μmol/L, and 0.12-17 μmol/L, respectively. The presented method was applied to quantify metabolites in human blood samples with satisfactory results. Graphical abstract.
Collapse
|
41
|
Sohouli E, Shahdost-Fard F, Rahimi-Nasrabadi M, Plonska-Brzezinska ME, Ahmadi F. Introducing a novel nanocomposite consisting of nitrogen-doped carbon nano-onions and gold nanoparticles for the electrochemical sensor to measure acetaminophen. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114309] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
42
|
Wu S, Tan Q, Forsberg E, Hu S, He S. In-situ dual-channel surface plasmon resonance fiber sensor for temperature-compensated detection of glucose concentration. OPTICS EXPRESS 2020; 28:21046-21061. [PMID: 32680152 DOI: 10.1364/oe.395524] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 06/24/2020] [Indexed: 06/11/2023]
Abstract
External temperature variations inevitably affect the accuracy of surface plasmon resonance (SPR) biosensors. To that end, we propose an ultra-compact label-free dual-channel SPR fiber sensor (DSPRFS) that can simultaneously measure the glucose concentration and ambient temperature in real-time. The proposed sensor is based on a unique dual-channel structure fabricated by etching a side-hole fiber (SHF), and has significantly higher spatial sensitivity than traditional SPR biosensors. After coating with silver and zinc oxide films, one channel was filled with polydimethylsiloxane (PDMS) to sense the ambient temperature, and the other channel was immobilized with glucose oxidase (GOx) enzyme for glucose sensing. The proposed sensor is analyzed theoretically, fabricated and characterized. Glucose concentration sensitivity and temperature sensitivity of the manufactured sensor sample were found to be as high as 6.156 nm/mMand -1.604 nm/°C with limits of detection (LOD) of 16.24 µM and 0.06 °C, respectively. The proposed sensor has an extremely compact structure, enables temperature compensation, and is suitable for in-situ monitoring and high-precision sensing of glucose and other biological analytes.
Collapse
|
43
|
Enhancement of Biosensors by Implementing Photoelectrochemical Processes. SENSORS 2020; 20:s20113281. [PMID: 32526947 PMCID: PMC7308923 DOI: 10.3390/s20113281] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 06/05/2020] [Accepted: 06/06/2020] [Indexed: 12/15/2022]
Abstract
Research on biosensors is growing in relevance, taking benefit from groundbreaking knowledge that allows for new biosensing strategies. Electrochemical biosensors can benefit from research on semiconducting materials for energy applications. This research seeks the optimization of the semiconductor-electrode interfaces including light-harvesting materials, among other improvements. Once that knowledge is acquired, it can be implemented with biological recognition elements, which are able to transfer a chemical signal to the photoelectrochemical system, yielding photo-biosensors. This has been a matter of research as it allows both a superior suppression of background electrochemical signals and the switching ON and OFF upon illumination. Effective electrode-semiconductor interfaces and their coupling with biorecognition units are reviewed in this work.
Collapse
|
44
|
Jafari S, Mahyad B, Hashemzadeh H, Janfaza S, Gholikhani T, Tayebi L. Biomedical Applications of TiO 2 Nanostructures: Recent Advances. Int J Nanomedicine 2020; 15:3447-3470. [PMID: 32523343 PMCID: PMC7234979 DOI: 10.2147/ijn.s249441] [Citation(s) in RCA: 135] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 04/16/2020] [Indexed: 12/13/2022] Open
Abstract
Titanium dioxide (TiO2) nanostructures are one of the most plentiful compounds that have emerged in various fields of technology such as medicine, energy and biosensing. Various TiO2 nanostructures (nanotubes [NTs] and nanowires) have been employed in photoelectrochemical (PEC) biosensing applications, greatly enhancing the detection of targets. TiO2 nanostructures, used as reinforced material or coatings for the bare surface of titanium implants, are excellent additive materials to compensate titanium implants deficiencies-like poor surface interaction with surrounding tissues-by providing nanoporous surfaces and hierarchical structures. These nanostructures can also be loaded by diversified drugs-like osteoporosis drugs, anticancer and antibiotics-and used as local drug delivery systems. Furthermore, TiO2 nanostructures and their derivatives are new emerging antimicrobial agents to overcome human pathogenic microorganisms. However, like all other nanomaterials, toxicity and biocompatibility of TiO2 nanostructures must be considered. This review highlights recent advances, along with the properties and numerous applications of TiO2-based nanostructure compounds in nano biosensing, medical implants, drug delivery and antibacterial fields. Moreover, in the present study, some recent advances accomplished on the pharmaceutical applications of TiO2 nanostructures, as well as its toxicity and biocompatibility, are presented.
Collapse
Affiliation(s)
- Sevda Jafari
- Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
- Student Research Committee, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Baharak Mahyad
- Department of Life Science Engineering, Faculty of New Science and Technologies, University of Tehran, Tehran, Islamic Republic of Iran
| | - Hadi Hashemzadeh
- Department of Nanobiotechnology, Tarbiat Modares University, Tehran, 14117, Islamic Republic of Iran
| | - Sajjad Janfaza
- Department of Nanobiotechnology, Tarbiat Modares University, Tehran, 14117, Islamic Republic of Iran
| | - Tooba Gholikhani
- Student Research Committee, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Islamic Republic of Iran
| | - Lobat Tayebi
- Marquette University School of Dentistry, Milwaukee, WI53233, USA
| |
Collapse
|
45
|
Pan M, Xie X, Liu K, Yang J, Hong L, Wang S. Fluorescent Carbon Quantum Dots-Synthesis,Functionalization and Sensing Application in FoodAnalysis. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E930. [PMID: 32403325 PMCID: PMC7279393 DOI: 10.3390/nano10050930] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 04/29/2020] [Accepted: 05/05/2020] [Indexed: 01/10/2023]
Abstract
Carbon quantum dots (CQDs) with stable physicochemical properties are one of theemerging carbon nanomaterials that have been studied in recent years. In addition to the excellentoptical properties such as photoluminescence, photobleaching resistance and light stability, thismaterial also has favorable advantages of good biocompatibility and easy functionalization, whichmake it an ideal raw material for constructing sensing equipment. In addition, CQDs can combinedwith other kinds of materials to form the nanostructured composites with unique properties, whichprovides new insights and ideas for the research of many fields. In the field of food analysis,emerging CQDs have been deeply studied in food composition analysis, detection and monitoringtrace harmful substances and made remarkable research progress. This article introduces andcompares the various methods for CQDs preparation and reviews its related sensing applicationsas a new material in food components analysis and food safety inspection in recent years. It isexpected to provide a significant guidance for the further study of CQDs in the field of foodanalysis and detection. CQDs; synthesis; fluorescent sensing; food analysis.
Collapse
Affiliation(s)
- Mingfei Pan
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Xiaoqian Xie
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Kaixin Liu
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Jingying Yang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Liping Hong
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Shuo Wang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (M.P.); (X.X.); (K.L.); (J.Y.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| |
Collapse
|
46
|
Li H, Guo C, Liu C, Ge L, Li F. Laser-induced graphene hybrid photoelectrode for enhanced photoelectrochemical detection of glucose. Analyst 2020; 145:4041-4049. [PMID: 32367085 DOI: 10.1039/d0an00252f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The combination of an electrocatalyst with a semiconductor light absorber is of great importance to increase the efficiency of photoelectrochemical (PEC) glucose detection. Here, in situ and synchronous fabrication of a Ni-based electrocatalyst (NiEC) and CdS semiconductor in laser-induced graphene (LIG) on indium-tin oxide glass is demonstrated via a one-step laser-induced solid phase transition. A series of component and structural characterization experiments suggest that the laser-induced NiEC uniformly disperses in the hybrid nanocomposite and exists mainly in the Ni0 and NiO states. Moreover, both electrochemical and PEC investigations confirm that the as-prepared hybrid photoelectrode exhibits excellent photoelectrocatalytic ability towards glucose, which is not only attributed to the strong synergistic interaction between CdS and NiEC, but also benefited from the high conductivity as well as 3D macroporous configuration of the simultaneously formed LIG, providing the key factor to achieve sensitive non-enzymatic PEC glucose sensors. Therefore, the laser-induced hybrid photoelectrode is then applied to the PEC detection of glucose, and a low detection limit of 0.4 μM is obtained with good stability, reproducibility, and selectivity. This study provides a promising paradigm for the facile and binder-free fabrication of an electrocatalyst-semiconductor-graphene hybrid photoelectrode, which will find potential applications in sensitive PEC biosensing for a broad range of analytes.
Collapse
Affiliation(s)
- Hui Li
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao, 266109, People's Republic of China.
| | | | | | | | | |
Collapse
|
47
|
Yang W, Wang X, Hao W, Wu Q, Peng J, Tu J, Cao Y. 3D hollow-out TiO 2 nanowire cluster/GOx as an ultrasensitive photoelectrochemical glucose biosensor. J Mater Chem B 2020; 8:2363-2370. [PMID: 32104865 DOI: 10.1039/d0tb00082e] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Ultra-high sensitivity is difficult to achieve using conventional enzymatic glucose biosensors due to the lack of exposed active sites and steric-hinderance effects. Thus, in the present study, we report a photoelectrochemical (PEC) enzymatic glucose biosensor based on 3-dimensional (3D) hollow-out titanium dioxide (TiO2) nanowire cluster (NWc)/glucose oxidase (GOx), providing more number of exposed active sites, thus constructing a sensor with a higher affinity toward glucose reaction. Excellent performance with an ultra-high sensitivity of 58.9 μA mM-1 cm-2 and 0-2 mM linear range with a determination limit of 8.7 μM was obtained for the detection of glucose. This study might provide a new approach to expose active sites efficiently for remarkable photoelectrochemical performances.
Collapse
Affiliation(s)
- Wenke Yang
- State Key Laboratory of Marine Resource Utilization in South China Sea, College of Material Science and Engineering, Hainan University, Haikou 570228, China.
| | | | | | | | | | | | | |
Collapse
|
48
|
Green Synthesis of S- and N-Codoped Carbon Nanospheres and Application as Adsorbent of Pb (II) from Aqueous Solution. INTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING 2020. [DOI: 10.1155/2020/9068358] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
In this paper, green and facile synthesis of sulfur- and nitrogen-codoped carbon nanospheres (CNs) was prepared from the extract of Hibiscus sabdariffa L by a direct hydrothermal method. Finally, sulfur-carbon nanospheres (CNs) were used as the adsorbent to remove Pb+2 ions from aqueous solutions because of the high surface area of S-CNs from CNs and N-CNs. The synthesized nanospheres were examined by Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD), field emission scanning electron microscopy, transmission electron microscopy (TEM), and nitrogen adsorption-desorption isotherms. The results show spherical shapes have a particle size of up to 65 nm with a high surface area capable of absorbing lead ions efficiently. Additionally, the factors affecting the process of adsorption that include equilibrium time, temperature, pH solution, ionic intensity, and adsorbent dose were studied. The equilibrium removal efficiency was studied employing Langmuir, Freundlich, and Temkin isotherm forms. The kinetic data were analyzed with two different kinetic models, and both apply to the adsorption process depending on the values of correlation coefficients. The thermodynamic parameters including Gibbs free energy (ΔG°), standard enthalpy change (ΔH°), and standard entropy change (ΔS°) were calculated for the adsorption process.
Collapse
|
49
|
Eco-friendly synthesis of tunable fluorescent carbon nanodots from Malus floribunda for sensors and multicolor bioimaging. J Photochem Photobiol A Chem 2020. [DOI: 10.1016/j.jphotochem.2019.112336] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
50
|
Li F, Yin H, Chen Y, Wang S, Li J, Zhang Y, Li C, Ai S. Preparation of P-g-C3N4-WS2 nanocomposite and its application in photoelectrochemical detection of 5-formylcytosine. J Colloid Interface Sci 2020; 561:348-357. [DOI: 10.1016/j.jcis.2019.10.117] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 10/31/2019] [Accepted: 10/31/2019] [Indexed: 10/25/2022]
|