1
|
Xue S, Zou J, Li J, Xu J, Chen H, Wang L, Gao Y, Duan X, Lu L. Electrochemical detection of carbendazim using molecularly imprinted poly(3,4-ethylenedioxythiophene) on Co,N co-doped hollow carbon nanocage@CNTs-modified electrode. Food Chem 2024; 456:140063. [PMID: 38878547 DOI: 10.1016/j.foodchem.2024.140063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 06/08/2024] [Accepted: 06/09/2024] [Indexed: 07/24/2024]
Abstract
Precisely detecting trace pesticides and their residues in food products is crucial for ensuring food safety. Herein, a high-performance electrochemical sensing platform was developed for the detection of carbendazim (CBZ) using Co,N co-doped hollow carbon nanocage@carbon nanotubes (Co,N-HC@CNTs) obtained from core-shell ZIF-8@ZIF-67 combined with a poly(3,4-ethylenedioxythiophene) (PEDOT) molecularly imprinted polymer (MIP). The Co,N-HC@CNTs exhibited excellent electrocatalytic performance, benefitting from the synergistic effect of CNTs that provide a large specific surface area and excellent electrical conductivity, Co,N co-doped carbon nanocages that offer high electrocatalytic activity and hollow nanocage structures that ensure rapid diffusion kinetics. The conductive PEDOT-MIP provided specific binding sites for CBZ detection and significantly amplified the detection signal. The sensor showed superior selectivity for CBZ with an extremely low detection limit of 1.67 pmol L-1. Moreover, the method was successfully applied to detect CBZ in tomato, orange and apple samples, achieving satisfactory recovery and accuracy, thus demonstrating its practical feasibility.
Collapse
Affiliation(s)
- Shuya Xue
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, Flexible Electronics Innovation Institute (FEII), School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China
| | - Jiamin Zou
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang 330045, PR China
| | - Jiapeng Li
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, Flexible Electronics Innovation Institute (FEII), School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China
| | - Jingkun Xu
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, Flexible Electronics Innovation Institute (FEII), School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China
| | - Hui Chen
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang 330045, PR China
| | - Linyu Wang
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang 330045, PR China.
| | - Yansha Gao
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang 330045, PR China
| | - Xuemin Duan
- Jiangxi Provincial Key Laboratory of Drug Design and Evaluation, Engineering Center of Jiangxi University for Fine Chemicals, Flexible Electronics Innovation Institute (FEII), School of Pharmacy, Jiangxi Science and Technology Normal University, Nanchang 330013, PR China.
| | - Limin Lu
- Key Laboratory of Crop Physiology, Ecology and Genetic Breeding, Ministry of Education, Key Laboratory of Chemical Utilization of Plant Resources of Nanchang, College of Science, Jiangxi Agricultural University, Nanchang 330045, PR China.
| |
Collapse
|
2
|
Ting WT, Ali MY, Mitea V, Wang MJ, Howlader MMR. Polyaniline-based bovine serum albumin imprinted electrochemical sensor for ultra-trace-level detection in clinical and food safety applications. Int J Biol Macromol 2024; 277:134137. [PMID: 39067725 DOI: 10.1016/j.ijbiomac.2024.134137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 07/16/2024] [Accepted: 07/22/2024] [Indexed: 07/30/2024]
Abstract
Monitoring bovine serum albumin (BSA) at ultra-low levels is crucial for clinical and food safety applications, as it plays a significant role in identifying various health conditions and potential risks, necessitating fast, trace-level detection of BSA. This study proposes an approach to address these challenges by employing molecularly imprinted polymer (MIP) to develop an ultra-trace-level and cost-effective BSA sensing platform. The MIP electrochemical sensor was developed using polyaniline (PANI) combined with the protein crosslinker glutaraldehyde (GA) to optimize BSA surface imprinting in the MIP. As a result, the sensor achieves a sensitivity of 1.24 μA/log(pg/mL), with a picomolar detectable limit of 2.3 pg/mL (0.035 pM) and a wide detection range from 20 pg/mL to 200,000 pg/mL (0.303 pM to 3030 pM), making it suitable for clinical and food safety applications. Additionally, the study explores the interaction between an acidic surfactant protein eluent (acetic acid with sodium dodecyl sulfate, AcOH-SDS) and BSA vacant sites, enhancing recognition and re-binding. The PANI-based MIP sensor demonstrates initial feasibility and practicality in commercial milk and real human serum, opening avenues for early disease detection and ensuring food safety in BSA-related immune responses.
Collapse
Affiliation(s)
- Wei-Ting Ting
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada; Department of Chemical Engineering, National Taiwan University of Science and Technology, No. 43 Keelung Road Section 4, Taipei 106, Taiwan; Taiwan Building Technology Center, National Taiwan University of Science and Technology, No. 43 Keelung Road Section 4, Taipei 106, Taiwan
| | - Md Younus Ali
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada
| | - Victor Mitea
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada
| | - Meng-Jiy Wang
- Department of Chemical Engineering, National Taiwan University of Science and Technology, No. 43 Keelung Road Section 4, Taipei 106, Taiwan.
| | - Matiar M R Howlader
- Department of Electrical and Computer Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada.
| |
Collapse
|
3
|
Cheng Q, Abdiryim T, Jamal R, Liu X, Xue C, Xie S, Tang X, Wei J. A novel molecularly imprinted electrochemical sensor from poly (3, 4-ethylenedioxythiophene)/chitosan for selective and sensitive detection of levofloxacin. Int J Biol Macromol 2024; 267:131321. [PMID: 38570001 DOI: 10.1016/j.ijbiomac.2024.131321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/01/2024] [Accepted: 03/30/2024] [Indexed: 04/05/2024]
Abstract
The improper usage of levofloxacin (LEV) endangers both environmental safety and human public health. Therefore, trace analysis and detection of LEV have extraordinary significance. In this paper, a novel molecularly imprinted polymer (MIP) electrochemical sensor was developed for the specific determination of LEV by electrochemical polymerization of o-phenylenediamine (o-PD) using poly(3,4-ethylenedioxythiophene)/chitosan (PEDOT/CS) with a porous structure and rich functional groups as a carrier and LEV as a template molecule. The morphology, structure and properties of the modified materials were analyzed and studied. The result showed that the electron transfer rate and the electroactive strength of the electrode surface are greatly improved by the interconnection of PEDOT and CS. Meanwhile, PEDOT/CS was assembled by imprinting with o-PD through non-covalent bonding, which offered more specific recognition sites and a larger surface area for the detection of LEV and effectively attracted LEV through intermolecular association. Under the optimized conditions, MIP/PEDOT/CS/GCE showed good detection performance for LEV in a wide linear range of 0.0019- 1000 μM, with a limit of detection (LOD, S/N = 3) of 0.4 nM. Furthermore, the sensor has good stability and selectivity, and exhibits excellent capabilities in the microanalysis of various real samples.
Collapse
Affiliation(s)
- Qian Cheng
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Tursun Abdiryim
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China.
| | - Ruxangul Jamal
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, Xinjiang, PR China.
| | - Xiong Liu
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Cong Xue
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Shuyue Xie
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Xinsheng Tang
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Jin Wei
- State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources; College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| |
Collapse
|
4
|
Ni X, Tang X, Wang D, Zhang J, Zhao L, Gao J, He H, Dramou P. Research progress of sensors based on molecularly imprinted polymers in analytical and biomedical analysis. J Pharm Biomed Anal 2023; 235:115659. [PMID: 37657406 DOI: 10.1016/j.jpba.2023.115659] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/12/2023] [Accepted: 08/16/2023] [Indexed: 09/03/2023]
Abstract
Molecularly imprinted polymers (MIPs) have had tremendous impact on biomimetic recognition due to their precise specificity and high affinity comparable to that of antibodies, which has shown the great advantages of easy preparation, good stability and low cost. The combination of MIPs with other analytical technologies can not only achieve rapid extraction and sensitive detection of target compounds, improving the level of analysis, but also achieve precise targeted delivery, in-vivo imaging and other applications. Among them, the recognition mechanism plays a vital role in chemical and biological sensing, while the improvement of the recognition element, such as the addition of new nanomaterials, can greatly improve the analytical performance of the sensor, especially in terms of selectivity. Currently, due to the need for rapid diagnosis and improved sensing properties (such as selectivity, stability, and cost-effectiveness), researchers are investigating new recognition elements and their combinations to improve the recognition capabilities of chemical sensing and bio-sensing. Therefore, this review mainly discusses the design strategies of optical sensors, electrochemical sensors and photoelectric sensors with molecular imprinting technology and their applications in environmental systems, food fields, drug detection and biology including bacteria and viruses.
Collapse
Affiliation(s)
- Xu Ni
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Xue Tang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Dan Wang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Jingjing Zhang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Linjie Zhao
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Jie Gao
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China
| | - Hua He
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China; Key Laboratory of Biomedical Functional Materials, China Pharmaceutical University, Nanjing 211198, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing 211198, China.
| | - Pierre Dramou
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing 211198, China; Key Laboratory of Biomedical Functional Materials, China Pharmaceutical University, Nanjing 211198, China.
| |
Collapse
|
5
|
Gao N, Pan J, Wang L, Cai Z, Chang G, Wu Y, He Y. Novel graphene electrochemical transistors incorporating zirconia inorganic molecular imprinted layer:Design, construction and application for highly sensitive and selective detection of acetaminophen. Anal Chim Acta 2023; 1269:341405. [PMID: 37290852 DOI: 10.1016/j.aca.2023.341405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 05/11/2023] [Accepted: 05/22/2023] [Indexed: 06/10/2023]
Abstract
Owing to their intrinsic amplifying effect together with chemical stability, graphene electrochemical transistor sensors (GECTs) are gaining momentum for sensing applications. However, the surface of GECTs for different detection substances must be modified with different recognition molecules, which was cumbersome and lack a universal method. Molecularly imprinted polymer (MIP) is a kind of polymer with specific recognition function for given molecules. Here, MIP and GECTs were combined to effectively solve the problem of weak selectivity of GECTs, and achieve the high sensitivity and selectivity of MIP-GECTs equipment in detecting acetaminophen (AP) in complex urine environment. A novel molecular imprinting sensor based on Au nanoparticles modified zirconia (ZrO2) inorganic molecular imprinting membrane on reduced graphene oxide (ZrO2-MIP-Au/rGO) was proposed. ZrO2-MIP-Au/rGO was synthesized by one-step electropolymerization using AP as template, ZrO2 precursor as the functional monomer. The -OH group on ZrO2 and the -OH/-CONH- group on AP were easily bonded by hydrogen bonding to form a MIP layer on the surface, which allows the sensor to have a large number of imprinted cavities for AP specific adsorption. As a proof of method, the GECTs based on ZrO2-MIP-Au/rGO functional gate electrode has the characteristics of wide linear range (0.1 nM-4 mM), low detection limit (0.1 nM) and high selectivity for AP detection. These achievements highlight the introduction of specific and selective MIP to GECTs with unique amplification function, which could effectively solve the problem of selectivity of GECTs in complex environments, suggesting the potential of MIP-GECTs in real-time diagnosis.
Collapse
Affiliation(s)
- Nan Gao
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China
| | - Junzi Pan
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China
| | - Lei Wang
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China
| | - Zhiwei Cai
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China
| | - Gang Chang
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China.
| | - Yuxiang Wu
- School of Physical Education, Jianghan University, Wuhan, 430056, China.
| | - Yunbin He
- Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, No.368 Youyi Avenue, Wuchang, Wuhan, 430062, China.
| |
Collapse
|
6
|
Kong J, Xu X, Ma Y, Miao J, Bian X. Rapid and Sensitive Detection of Sulfamethizole Using a Reusable Molecularly Imprinted Electrochemical Sensor. Foods 2023; 12:foods12081693. [PMID: 37107488 PMCID: PMC10137692 DOI: 10.3390/foods12081693] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/14/2023] [Accepted: 04/17/2023] [Indexed: 04/29/2023] Open
Abstract
Efficient methods for monitoring sulfonamides (SAs) in water and animal-source foods are of great importance to achieve environmental safety and protect human health. Here, we demonstrate a reusable and label-free electrochemical sensor for the rapid and sensitive detection of sulfamethizole based on an electropolymerized molecularly imprinted polymer (MIP) film as the recognition layer. To achieve effective recognition, monomer screening among four kinds of 3-substituted thiophenes was performed by computational simulation and subsequent experimental evaluation, and 3-thiopheneethanol was finally selected. MIP synthesis is very fast and green, and can be in situ fabricated on the transducer surface within 30 min in an aqueous solution. The preparation process of the MIP was characterized by electrochemical techniques. Various parameters affecting MIP fabrication and its recognition response were investigated in detail. Under optimized experimental conditions, good linearity in the range of 0.001-10 μM and a low determination limit of 0.18 nM were achieved for sulfamethizole. The sensor showed excellent selectivity, which can distinguish between structurally similar SAs. In addition, the sensor displayed good reusability and stability. Even after 7 days of storage, or being reused 7 times, higher than 90% of the initial determination signals were retained. The practical applicability of the sensor was also demonstrated in spiked water and milk samples at the nM determination level with satisfactory recoveries. Compared to relevant methods for SAs, this sensor is more convenient, rapid, economical, and eco-friendly, and had comparable or even higher sensitivity, which offered a simple and efficient method for SA detection.
Collapse
Affiliation(s)
- Jie Kong
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaoli Xu
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Yixin Ma
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Junjian Miao
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
| | - Xiaojun Bian
- College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China
- Laboratory of Quality and Safety Risk Assessment for Aquatic Product on Storage and Preservation (Shanghai), Ministry of Agriculture, Shanghai 201306, China
- Shanghai Engineering Research Center of Aquatic-Product Processing & Preservation, Shanghai 201306, China
| |
Collapse
|
7
|
Aaryashree, Choudhary AK, Yoshimi Y. Disposable Sensor Chips with Molecularly Imprinted Carbon Paste Electrodes for Monitoring Anti-Epileptic Drugs. SENSORS (BASEL, SWITZERLAND) 2023; 23:3271. [PMID: 36991982 PMCID: PMC10059048 DOI: 10.3390/s23063271] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/07/2023] [Accepted: 03/17/2023] [Indexed: 08/12/2023]
Abstract
Epilepsy is a neurological disorder that affects millions of people worldwide. Anti-epileptic drugs (AEDs) are critical for their management. However, the therapeutic window is narrow, and traditional laboratory-based therapeutic drug monitoring (TDM) methods can be time consuming and unsuitable for point-of-care testing. To address this issue, we developed a disposable sensor chip based on molecularly imprinted polymer-modified carbon paste electrodes (MIP-CPs) for the TDM of AEDs such as phenobarbital (PB), carbamazepine (CBZ), and levetiracetam (LEV). In this work, functional monomers (methacrylic acid) and crosslinking monomers (methylene bisacrylamide and ethylene glycol dimethacrylate) were copolymerized in the presence of the AED template and grafted on the graphite particles by simple radical photopolymerization. The grafted particles were mixed with silicon oil, dissolving ferrocene as a redox marker to make the MIP-carbon paste (CP). Disposable sensor chips were fabricated by packing the MIP-CP into the base made of poly (ethylene glycol terephthalate) (PET) film. The sensor's sensitivity was determined using differential pulse voltammetry (DPV), carried out on a single sensor chip for each operation. Linearity was obtained from 0-60 μg/mL in PB and LEV and 0-12 μg/mL in CBZ, covering their respective therapeutic range. The time taken for each measurement was around 2 min. The experiment using whole bovine blood and bovine plasma indicated that the existence of species that interfered had a negligible effect on the test's sensitivity. This disposable MIP sensor provides a promising approach for point-of-care testing and facilitating the management of epilepsy. Compared with existing tests, this sensor offers a faster and more accurate way to monitor AEDs, which is crucial for optimizing therapy and improving patient outcomes. Overall, the proposed disposable sensor chip based on MIP-CPs represents a significant advancement in AED monitoring, with the potential for rapid, accurate, and convenient point-of-care testing.
Collapse
Affiliation(s)
- Aaryashree
- Innovative Global Program, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan;
| | - Ashish Kumar Choudhary
- Department Applied Chemistry, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan
| | - Yasuo Yoshimi
- Department Applied Chemistry, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan
| |
Collapse
|
8
|
Tian Q, She Y, Zhu Y, Dai D, Shi M, Chu W, Cai T, Tsai HS, Li H, Jiang N, Fu L, Xia H, Lin CT, Ye C. Highly Sensitive and Selective Dopamine Determination in Real Samples Using Au Nanoparticles Decorated Marimo-like Graphene Microbead-Based Electrochemical Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23052870. [PMID: 36905070 PMCID: PMC10007331 DOI: 10.3390/s23052870] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 02/21/2023] [Accepted: 03/03/2023] [Indexed: 05/05/2023]
Abstract
A sensitive and selective electrochemical dopamine (DA) sensor has been developed using gold nanoparticles decorated marimo-like graphene (Au NP/MG) as a modifier of the glassy carbon electrode (GCE). Marimo-like graphene (MG) was prepared by partial exfoliation on the mesocarbon microbeads (MCMB) through molten KOH intercalation. Characterization via transmission electron microscopy confirmed that the surface of MG is composed of multi-layer graphene nanowalls. The graphene nanowalls structure of MG provided abundant surface area and electroactive sites. Electrochemical properties of Au NP/MG/GCE electrode were investigated by cyclic voltammetry and differential pulse voltammetry techniques. The electrode exhibited high electrochemical activity towards DA oxidation. The oxidation peak current increased linearly in proportion to the DA concentration in a range from 0.02 to 10 μM with a detection limit of 0.016 μM. The detection selectivity was carried out with the presence of 20 μM uric acid in goat serum real samples. This study demonstrated a promising method to fabricate DA sensor-based on MCMB derivatives as electrochemical modifiers.
Collapse
Affiliation(s)
- Qichen Tian
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Yuanbin She
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
| | - Yangguang Zhu
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Dan Dai
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Mingjiao Shi
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Wubo Chu
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Tao Cai
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Hsu-Sheng Tsai
- Laboratory for Space Environment and Physical Sciences, Harbin Institute of Technology, Harbin 150001, China
- School of Physics, Harbin Institute of Technology, Harbin 150001, China
| | - He Li
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Nan Jiang
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Hongyan Xia
- State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, Xi’an 710049, China
- Correspondence: (H.X.); (C.-T.L.); (C.Y.)
| | - Cheng-Te Lin
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Correspondence: (H.X.); (C.-T.L.); (C.Y.)
| | - Chen Ye
- Qianwan Institute, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
- Correspondence: (H.X.); (C.-T.L.); (C.Y.)
| |
Collapse
|
9
|
Recent advances in electrochemical screening of tricyclic drug carbamazepine: A mini-review. TALANTA OPEN 2022. [DOI: 10.1016/j.talo.2022.100147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
10
|
Electrochemical biosensor based on efficient target-trigger T-structure recycling with dual strand displacement amplification for sensing miRNA-155. Anal Chim Acta 2022; 1238:340609. [DOI: 10.1016/j.aca.2022.340609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 11/02/2022] [Accepted: 11/10/2022] [Indexed: 11/18/2022]
|
11
|
Chen H, Guo J, Wang Y, Dong W, Zhao Y, Sun L. Bio-Inspired Imprinting Materials for Biomedical Applications. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2202038. [PMID: 35908804 PMCID: PMC9534966 DOI: 10.1002/advs.202202038] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 06/08/2022] [Indexed: 05/27/2023]
Abstract
Inspired by the recognition mechanism of biological molecules, molecular imprinting techniques (MITs) are imparted with numerous merits like excellent stability, recognition specificity, adsorption properties, and easy synthesis processes, and thus broaden the avenues for convenient fabrication protocol of bio-inspired molecularly imprinted polymers (MIPs) with desirable functions to satisfy the extensive demands of biomedical applications. Herein, the recent research progress made with respect to bio-inspired imprinting materials is discussed in this review. First, the underlying mechanism and basic components of a typical molecular imprinting procedure are briefly explored. Then, emphasis is put on the introduction of diverse MITs and novel bio-inspired imprinting materials. Following these two sections, practical applications of MIPs in the field of biomedical science are focused on. Last but not least, perspectives on the remaining challenges and future development of bio-inspired imprinting materials are presented.
Collapse
Affiliation(s)
- Hanxu Chen
- Department of Rheumatology and ImmunologyNanjing Drum Tower HospitalSchool of Biological Science and Medical EngineeringSoutheast UniversityNanjing210096P. R. China
| | - Jiahui Guo
- Department of Rheumatology and ImmunologyNanjing Drum Tower HospitalSchool of Biological Science and Medical EngineeringSoutheast UniversityNanjing210096P. R. China
| | - Yu Wang
- Department of Rheumatology and ImmunologyNanjing Drum Tower HospitalSchool of Biological Science and Medical EngineeringSoutheast UniversityNanjing210096P. R. China
| | - Weiliang Dong
- State Key Laboratory of Materials‐Oriented Chemical EngineeringCollege of Biotechnology and Pharmaceutical EngineeringNanjing Tech UniversityNanjing211800P. R. China
| | - Yuanjin Zhao
- Department of Rheumatology and ImmunologyNanjing Drum Tower HospitalSchool of Biological Science and Medical EngineeringSoutheast UniversityNanjing210096P. R. China
- Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health)Wenzhou InstituteUniversity of Chinese Academy of SciencesWenzhouZhejiang325001P. R. China
| | - Lingyun Sun
- Department of Rheumatology and ImmunologyNanjing Drum Tower HospitalSchool of Biological Science and Medical EngineeringSoutheast UniversityNanjing210096P. R. China
- Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision and Brain Health)Wenzhou InstituteUniversity of Chinese Academy of SciencesWenzhouZhejiang325001P. R. China
| |
Collapse
|
12
|
An DY, Pu WR, Wang Y, Xue-Zhang, Huang YP, Liu ZS. Improving sorption performance of a molecularly imprinted monolithic column by doping mesoporous molecular sieve SBA-15. Mikrochim Acta 2022; 189:85. [PMID: 35129695 DOI: 10.1007/s00604-022-05192-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/13/2022] [Indexed: 01/07/2023]
Abstract
For the first time a hybrid molecularly imprinted polymer (MIP) doped with 3-(trimethoxysilyl) propyl methacrylate (γ-MPS)-modified mesoporous molecular sieve SBA-15 for target peptide recognition has been developed. Zinc acrylate and methacrylic acid were used as binary functional monomers, and ethylene dimethacrylate was used as cross-linking agent to prepare an imprinted monolith against Val-Tyr-Ala-Leu-Lys(glutarylation) (VYALKglu). The morphology of the polymers was characterized by scanning electron microscopy, FT-IR spectroscopy, energy dispersive spectroscopy, and 1H NMR. The SBA-15-MPS MIP showed high recovery of 87.1% and the IF of 12.9 for the enrichment of the template peptide. When the template peptide concentration ranged from 5 to 90 μg mL-1, the correlation coefficients (R2) for the calibration function obtained was better 0.999. The limit of detection (LOD, 0.30 μg mL-1) and limit of quantification (LOQ, 1.0 μg mL-1) were achieved for signal-to-noise ratios of 3:1 and 10:1, respectively. When other kinds of synthetic peptides were used as analogs, the selectivity of the SBA-15-MPS MIP was much better than the SBA-15-MPS NIP (without template peptides) with relative selectivity coefficients of 52.8-265. In contrast, little quinolones and biogenic amines are adsorbed with the SBA-15-MPS MIP. The SBA-15-MPS MIP could enrich VYALKglu from spiked histone digestion with the average recovery of 87.8% and the relative standard deviation (RSD) of 0.99%. As a conclusion, doping of SBA-15 is an effective approach to the improvement of performance of molecularly imprinted monolith.
Collapse
Affiliation(s)
- Dong-Yu An
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China
| | - Wan-Rong Pu
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China
| | - Yang Wang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China
| | - Xue-Zhang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China
| | - Yan-Ping Huang
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China.
| | - Zhao-Sheng Liu
- Tianjin Key Laboratory On Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), School of Pharmacy, Tianjin Medical University, Tianjin, 300070, China.
| |
Collapse
|
13
|
Hammoud A, Assaf H, Savaria Y, Nguyen DK, Sawan M. A Molecular Imprinted PEDOT CMOS Chip-Based Biosensor for Carbamazepine Detection. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:15-23. [PMID: 34962875 DOI: 10.1109/tbcas.2021.3138942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
A miniaturized biosensor for carbamazepine (CBZ) detection and quantification was designed, implemented and fabricated. The 1×1 mm2 CMOS chip was packaged and coupled with a 3-electrode electrochemical cell. A complete characterization of the sensor was conducted via two steps: 1) Molecular imprinting of PEDOT polymer sites by cyclic voltammetry (CV) on glassy carbon electrode (GCE) surfaces; and 2) Quantification of CBZ solutions through both CV, and a current peak detection circuitry. The proposed biosensor offered high-selectivity and high-sensitivity to CBZ molecules. Scanning electron microscopy (SEM) was utilized to validate the synthesis of the PEDOT chains. CBZ removal from the imprinted polymer was conducted through soaking the modified GCEs in acetonitrile (ACN). Extraction was then confirmed by ultraviolet-visible (UV-vis) spectroscopy and CV analyzing data from pre- and post-template extraction. Furthermore, in order to characterize the electrodes' response to CBZ levels in phosphate buffered solution (PBS) with [Fe(CN)6]3-/4- as a redox pair/mediator, CV and peak detection was conducted resulting in redox peak currents vs. CBZ concentration graphs. The limits of detection (LOD) and quantification (LOQ) were calculated to be 2.04 and 6.2 μg/mL respectively. Finally, selectivity towards CBZ was validated by studying the effect of valproic acid (VPA) and phenytoin (PHT) on the biosensor's performance. The proposed biosensor is highly sensitive and selective to CBZ molecules, simple to construct and easy to operate.
Collapse
|
14
|
Song Z, Zhai X, Jiang C, Chen R, Ye S, Tong J, Dramou P, He H. Sensitive and selective detection of carbamazepine in serum samples by bionic double-antibody sandwich method based on cucurbit[7]uril and molecular imprinted polymers. Biosens Bioelectron 2022; 203:114037. [PMID: 35123315 DOI: 10.1016/j.bios.2022.114037] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/20/2022] [Accepted: 01/21/2022] [Indexed: 12/17/2022]
Abstract
A novel bionic enzyme-linked immunosorbent assay (BELISA) based on double-antibody sandwich method is firstly designed for the detection of carbamazepine (CBZ) in human serum samples. In this BELISA system, cucurbit[7]uril (CB[7]) is employed as an artificial capture antibody (cAb), and molecularly imprinted polymers (MIPs) is used as an artificial detection antibody (dAb). Nanozymes (PdNPs) as signal generators are integrated with MIPs. This couple of bionic antibodies exhibits not only the excellent physical and chemical stability, but also the superior molecular recognition ability. Based on two bionic antibodies that can selectively recognize different sites of CBZ molecule, a new BELISA method has been constructed for the first time. The proposed BELISA method displays a good linear relationship ranging from 2 to 20 μg mL-1. The detection limit is 0.37 μg mL-1, which can well meet clinical testing demand. It provides a more stable and economical method for clinical therapeutic drug monitoring (TDM).
Collapse
Affiliation(s)
- Zhaorui Song
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China; Bohai rim Advanced Research Institute for Drug Discovery, Yantai, 264003, Shandong, China
| | - Xinhui Zhai
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Chenrui Jiang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Rong Chen
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Sijing Ye
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Jinzhe Tong
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Pierre Dramou
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China.
| | - Hua He
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China; Key Laboratory of Biomedical Functional Materials, China Pharmaceutical University, Nanjing, 211100, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing, 211198, China.
| |
Collapse
|
15
|
Saha P, Moitra P, Bhattacharjee U, Bhattacharya S. Selective pathological and intracellular detection of human serum albumin by photophysical and electrochemical techniques using a FRET-based molecular probe. Biosens Bioelectron 2022; 203:114007. [DOI: 10.1016/j.bios.2022.114007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 12/25/2021] [Accepted: 01/13/2022] [Indexed: 12/31/2022]
|
16
|
Bian S, Tao Y, Zhu Z, Zhu P, Wang Q, Wu H, Sawan M. On-Site Biolayer Interferometry-Based Biosensing of Carbamazepine in Whole Blood of Epileptic Patients. BIOSENSORS 2021; 11:516. [PMID: 34940273 PMCID: PMC8699405 DOI: 10.3390/bios11120516] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/02/2021] [Accepted: 12/11/2021] [Indexed: 06/14/2023]
Abstract
On-site monitoring of carbamazepine (CBZ) that allows rapid, sensitive, automatic, and high-throughput detection directly from whole blood is of urgent demand in current clinical practice for precision medicine. Herein, we developed two types (being indirect vs. direct) of fiber-optic biolayer interferometry (FO-BLI) biosensors for on-site CBZ monitoring. The indirect FO-BLI biosensor preincubated samples with monoclonal antibodies towards CBZ (MA-CBZ), and the mixture competes with immobilized CBZ to bind towards MA-CBZ. The direct FO-BLI biosensor used sample CBZ and CBZ-horseradish peroxidase (CBZ-HRP) conjugate to directly compete for binding with immobilized MA-CBZ, followed by a metal precipitate 3,3'-diaminobenzidine to amplify the signals. Indirect FO-BLI detected CBZ within its therapeutic range and was regenerated up to 12 times with negligible baseline drift, but reported results in 25 min. However, Direct FO-BLI achieved CBZ detection in approximately 7.5 min, down to as low as 10 ng/mL, with good accuracy, specificity and negligible matric interference using a high-salt buffer. Validation of Direct FO-BLI using six paired sera and whole blood from epileptic patients showed excellent agreement with ultra-performance liquid chromatography. Being automated and able to achieve high throughput, Direct FO-BLI proved itself to be more effective for integration into the clinic by delivering CBZ values from whole blood within minutes.
Collapse
Affiliation(s)
- Sumin Bian
- CenBRAIN Labs, School of Engineering, Westlake University, Hangzhou 310024, China
| | - Ying Tao
- College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, China; (Y.T.); (P.Z.)
| | - Zhoule Zhu
- Department of Neurosurgery, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China; (Z.Z.); (H.W.)
| | - Peixi Zhu
- College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, China; (Y.T.); (P.Z.)
| | - Qiqin Wang
- Institute of Pharmaceutical Analysis, College of Pharmacy, Jinan University, Guangzhou 510632, China;
| | - Hemmings Wu
- Department of Neurosurgery, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China; (Z.Z.); (H.W.)
| | - Mohamad Sawan
- CenBRAIN Labs, School of Engineering, Westlake University, Hangzhou 310024, China
| |
Collapse
|
17
|
MXene/carbon nanohorns decorated with conductive molecularly imprinted poly(hydroxymethyl-3,4-ethylenedioxythiophene) for voltammetric detection of adrenaline. Mikrochim Acta 2021; 188:420. [PMID: 34782933 DOI: 10.1007/s00604-021-05079-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 10/24/2021] [Indexed: 10/19/2022]
Abstract
A novel molecularly imprinted sensor was developed for the voltammetric determination of adrenaline (AD). MXene/carbon nanohorn (MXene/CNH) composite with good electric conductivity and enormous accessible active sites was firstly introduced as catalytic substrate. Subsequently, molecularly imprinted polymer (MIP) film was fabricated in mixed solutions containing hydroxymethyl-3,4-ethylenedioxythiophene (functional monomer) and AD (template) through electro-polymerization process. A molecularly imprinted sensor was formed after removing the template. The morphology and elemental composition of the prepared composites were studied by scanning electron microscopy and X-ray photoelectron spectroscopy. Cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) were used to investigate the electrochemical performance of the molecularly imprinted sensors. Under optimized conditions, the designed sensor displays a wide linear range from 1.0 nM to 60.0 μM and a low limit of detection of 0.3 nM. The developed sensor also presents good selectivity, reproducibility and long-term stability, and satisfactory feasibility in practical sample analysis. MXene/carbon nanohorns decorated with conductive molecularly imprinted poly(hydroxymethyl-3,4-ethylenedioxythiophene) was proposed for highly sensitive and selective detection of adrenaline.
Collapse
|
18
|
Ultrasensitive detection and removal of carbamazepine in wastewater using UCNPs functionalized with thin-shell MIPs. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106674] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|