1
|
Rocha-Melogno L, Xi J, Deshusses MA. Experimental evaluation of a full-scale in-duct UV germicidal irradiation system for bioaerosols inactivation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 947:174432. [PMID: 38960181 DOI: 10.1016/j.scitotenv.2024.174432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 06/03/2024] [Accepted: 06/30/2024] [Indexed: 07/05/2024]
Abstract
Bioaerosols control techniques, especially ultraviolet germicidal irradiation (UVGI) are gaining attention due to increasing needs for controlling of health risk caused by airborne biocontaminants. The effectiveness of a full-scale in-duct UVGI air disinfection system was investigated. One bacterium, a wild type Escherichia coli, and three fungal spores, Penicillium aragonense, Rhodotorula glutinis, and Cladosporium sp., were selected as test organisms and their inactivation under different conditions representative of a real application in HVAC systems were investigated. The results demonstrated that inactivation of airborne E. coli by the UVGI system was extremely effective, with >99.5 % of the input E. coli inactivated at a residence time lower than 0.36 s in the disinfection section. Airborne fungal spores were less susceptible to UV irradiation than E. coli. Under same conditions, viable counts reduction of P. aragonense, R. glutinis, and Cladosporium sp. spores were 53 %, 63 % and 73 %, respectively. The effect of UV light intensity, air flowrate and relative humidity were analyzed separately. A simplified model based on redefinition of the parameters in the classical inactivation kinetic equation was used to simulate the inactivation of airborne contaminants in the in-duct system under different conditions. The results showed that the simplified model was adequate to estimate disinfection efficacy of different bioaerosols by the UVGI system which could be useful for system design. Overall, this study shows that such in-duct UVGI systems can provide significant control of bioaerosols.
Collapse
Affiliation(s)
| | - Jinying Xi
- Environmental Simulation and Pollution Control State Key Joint Laboratory, School of Environment, Tsinghua University, Beijing 100084, China
| | - Marc A Deshusses
- Department of Civil and Environmental Engineering, Box 90287, Duke University, Durham, NC 27708, USA.
| |
Collapse
|
2
|
Monika, Madugula SK, Kondabagil K, Kunwar A. Far-UVC (222 nm) irradiation effectively inactivates ssRNA, dsRNA, ssDNA, and dsDNA viruses as compared to germicidal UVC (254 nm). Photochem Photobiol 2024. [PMID: 38736273 DOI: 10.1111/php.13961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/23/2024] [Accepted: 04/24/2024] [Indexed: 05/14/2024]
Abstract
Ultraviolet-C (UVC) irradiation is being used as an effective approach for the disinfection of pathogenic viruses present in air, surfaces, and water. Recently, far-UVC radiation (222 nm) emitted by KrCl* (krypton-chloride) excimer lamps have been recommended for disinfecting high-risk public spaces to reduce the presence and transmission of infectious viruses owing to limited human health exposure risks as compared to germicidal UVC (254 nm). In this study, the UVC inactivation performances of individual filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were determined against four viruses, bacteriophages MS2, Phi6, M13, and T4, having different genome compositions (ssRNA, dsRNA, ssDNA and dsDNA, respectively) and shapes (i.e., spherical (Phi6), linear (M13), and icosahedral (MS2 and T4)). Here, the disinfection efficacies of filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were evaluated for highly concentrated virus droplets that mimic the virus-laden droplets released from the infected person and deposited on surfaces as fomites. Filtered KrCl* excimer (222 nm) showed significantly better inactivation against all viruses having different genome compositions and structures compared to germicidal UVC (254 nm). The obtained sensitivity against the filtered KrCl* excimer (222 nm) was found to be in the order, T4 > M13 > Phi6 > MS2 whereas for the germicidal UVC (254 nm) it was T4 > M13 > MS2 > Phi6. These results provide a strong basis to promote the use of filtered KrCl* excimer lamps (222 nm) in disinfecting contagious viruses and to limit the associated disease spread in public places and other high-risk areas.
Collapse
Affiliation(s)
- Monika
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Santhosh Kumar Madugula
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Kiran Kondabagil
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Ambarish Kunwar
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
- Koita Centre for Digital Health (KCDH), Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| |
Collapse
|
3
|
Alqarni Z, Rezgui Y, Petri I, Ghoroghi A. Viral infection transmission and indoor air quality: A systematic review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 923:171308. [PMID: 38432379 DOI: 10.1016/j.scitotenv.2024.171308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/03/2024] [Accepted: 02/25/2024] [Indexed: 03/05/2024]
Abstract
Respiratory disease transmission in indoor environments presents persistent challenges for health authorities, as exemplified by the recent COVID-19 pandemic. This underscores the urgent necessity to investigate the dynamics of viral infection transmission within indoor environments. This systematic review delves into the methodologies of respiratory infection transmission in indoor settings and explores how the quality of indoor air (IAQ) can be controlled to alleviate this risk while considering the imperative of sustainability. Among the 2722 articles reviewed, 178 were retained based on their focus on respiratory viral infection transmission and IAQ. Fifty eight articles delved into SARS-CoV-2 transmission, 21 papers evaluated IAQ in contexts of other pandemics, 53 papers assessed IAQ during the SARS-CoV-2 pandemic, and 46 papers examined control strategies to mitigate infectious transmission. Furthermore, of the 46 papers investigating control strategies, only nine considered energy consumption. These findings highlight clear gaps in current research, such as analyzing indoor air and surface samples for specific indoor environments, oversight of indoor and outdoor parameters (e.g., temperature, relative humidity (RH), and building orientation), neglect of occupancy schedules, and the absence of considerations for energy consumption while enhancing IAQ. This study distinctly identifies the indoor environmental conditions conducive to the thriving of each respiratory virus, offering IAQ trade-offs to mitigate the risk of dominant viruses at any given time. This study argues that future research should involve digital twins in conjunction with machine learning (ML) techniques. This approach aims to enhance IAQ by analyzing the transmission patterns of various respiratory viruses while considering energy consumption.
Collapse
Affiliation(s)
- Zahi Alqarni
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK; School of Computer Science, King Khalid University, Abha 62529, Saudi Arabia.
| | - Yacine Rezgui
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ioan Petri
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| | - Ali Ghoroghi
- School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
| |
Collapse
|
4
|
Luo Q, Liu W, Liao J, Gu Z, Fan X, Luo Z, Zhang X, Hang J, Ou C. COVID-19 transmission and control in land public transport: A literature review. FUNDAMENTAL RESEARCH 2024; 4:417-429. [PMID: 38933205 PMCID: PMC11197583 DOI: 10.1016/j.fmre.2023.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 06/28/2024] Open
Abstract
Land public transport is an important link within and between cities, and how to control the transmission of COVID-19 in land public transport is a critical issue in our daily lives. However, there are still many inconsistent opinions and views about the spread of SARS-CoV-2 in land public transport, which limits our ability to implement effective interventions. The purpose of this review is to overview the literature on transmission characteristics and routes of the epidemic in land public transport, as well as to investigate factors affecting its spread and provide feasible measures to mitigate the infection risk of passengers. We obtained 898 papers by searching the Web of Science, Pubmed, and WHO global COVID database by keywords, and finally selected 45 papers that can address the purpose of this review. Land public transport is a high outbreak area for COVID-19 due to characteristics like crowding, inadequate ventilation, long exposure time, and environmental closure. Different from surface touch transmission and drop spray transmission, aerosol inhalation transmission can occur not only in short distances but also in long distances. Insufficient ventilation is the most important factor influencing long-distance aerosol transmission. Other transmission factors (e.g., interpersonal distance, relative orientation, and ambient conditions) should be noticed as well, which have been summarized in this paper. To address various influencing factors, it is essential to suggest practical and efficient preventive measures. Among these, increased ventilation, particularly the fresh air (i.e., natural ventilation), has proven to effectively reduce indoor infection risk. Many preventive measures are also effective, such as enlarging social distance, avoiding face-to-face orientation, setting up physical partitions, disinfection, avoiding talking, and so on. As research on the epidemic has intensified, people have broken down many perceived barriers, but more comprehensive studies on monitoring systems and prevention measures in land public transport are still needed.
Collapse
Affiliation(s)
- Qiqi Luo
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
- Key Laboratory of Urban Meteorology, China Meteorological Administration, Beijing 100089, China
- China Meteorological Administration Xiong'an Atmospheric Boundary Layer Key Laboratory, Xiong'an 070001, China
- Key Laboratory of Tropical Atmosphere-Ocean System (Sun Yat-sen University), Ministry of Education, Zhuhai 519000, China
| | - Wenbing Liu
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
| | - Jiayuan Liao
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
| | - Zhongli Gu
- Guangdong Fans-tech Agro Co., Ltd, Yunfu 527300, China
| | - Xiaodan Fan
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
| | - Zhiwen Luo
- Welsh School of Architecture, Cardiff University, Cardiff CF10 3XQ, United Kingdom
| | - Xuelin Zhang
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
| | - Jian Hang
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
- Key Laboratory of Urban Meteorology, China Meteorological Administration, Beijing 100089, China
- China Meteorological Administration Xiong'an Atmospheric Boundary Layer Key Laboratory, Xiong'an 070001, China
- Key Laboratory of Tropical Atmosphere-Ocean System (Sun Yat-sen University), Ministry of Education, Zhuhai 519000, China
| | - Cuiyun Ou
- School of Atmospheric Sciences, Sun Yat-sen University, and Southern Marine Science and Engineering Guangdong Laboratory, Zhuhai 519082, China
| |
Collapse
|
5
|
Lu YH, Wang RX, Liu HL, Lai ACK. Evaluating the Performance of UV Disinfection across the 222-365 nm Spectrum against Aerosolized Bacteria and Viruses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6868-6877. [PMID: 38593035 DOI: 10.1021/acs.est.3c08675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Bioaerosols play a significant role in the transmission of many infectious diseases, especially in enclosed indoor environments. Ultraviolet (UV) disinfection has demonstrated a high efficacy in inactivating microorganisms suspended in the air. To develop more effective and efficient UV disinfection protocols, it is necessary to evaluate and optimize the effectiveness of UV disinfection against aerosolized bacteria and viruses across the entire UV spectrum. In this study, we evaluated the performance of UV disinfection across the UV spectrum, ranging from 222 to 365 nm, against aerosolized bacteria and viruses, including Escherichia coli, Staphylococcus epidermidis, Salmonella enterica, MS2, P22, and Phi6. Six commonly available UV sources, including gas discharge tubes and light-emitting diodes with different emission spectra, were utilized, and their performance in terms of inactivation efficacy, action spectrum, and energy efficiency was determined. Among these UV sources, the krypton chloride excilamp emitting at a peak wavelength of 222 nm was the most efficient in inactivating viral bioaerosols. A low-pressure mercury lamp emitting at 254 nm performed well on both inactivation efficacy and energy efficiency. A UV light-emitting diode emitting at 268 nm demonstrated the highest bacterial inactivation efficacy, but required approximately 10 times more energy to achieve an equivalent inactivation level compared with that of the krypton chloride excilamp and low-pressure mercury lamp. This study provides insights into UV inactivation on bioaerosols, which can guide the development of effective wavelength-targeted UV air disinfection technologies and may significantly help reduce bioaerosol transmission in public areas.
Collapse
Affiliation(s)
- Y H Lu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - R X Wang
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - H L Liu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - A C K Lai
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| |
Collapse
|
6
|
Haowei Y, Mahyuddin N, Bin Nik Ghazali NN, Wang Z, Liu Y, Pan S, Badruddin IA. A critical review of research methodologies for COVID-19 transmission in indoor built environment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2024:1-65. [PMID: 38385569 DOI: 10.1080/09603123.2024.2308731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 01/17/2024] [Indexed: 02/23/2024]
Abstract
The Coronavirus Disease 2019 (COVID-19) has caused massive losses for the global economy. Scholars have used different methods to study the transmission mode and influencing factors of the virus to find effective methods to provide people with a healthy built environment. However, these studies arrived at different or even contradictory conclusions. This review presents the main research methodologies utilized in this field, summarizes the main investigation methods, and critically discusses their related conclusions. Data statistical analysis, sample collection, simulation models, and replication transmission scenarios are the main research methods. The summarized conclusion for prevention from all reviewed papers are: adequate ventilation and proper location of return air vents, proper use of personal protective equipment, as well as the reasonable and strict enforcement of policies are the main methods for reducing the transmission. Recommendations including standardized databases, causation clarification, rigorous experiment design, improved simulation accuracy and verification are provided.
Collapse
Affiliation(s)
- Yu Haowei
- Centre for Building, Construction & Tropical Architecture (BuCTA), Faculty of Built Environment, University of Malaya, Kuala Lumpur, Malaysia
| | - Norhayati Mahyuddin
- Centre for Building, Construction & Tropical Architecture (BuCTA), Faculty of Built Environment, University of Malaya, Kuala Lumpur, Malaysia
| | - Nik Nazri Bin Nik Ghazali
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Zeyu Wang
- China Nuclear Power Engineering Co. Ltd, Beijing Institute of Nuclear Engineering, Beijing, China
| | - Yiqiao Liu
- Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Song Pan
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
- Key Laboratory for Comprehensive Energy Saving of Cold Regions Architecture of Ministry of Education, Jilin Jianzhu University, Changchun, PR China
| | - Irfan Anjum Badruddin
- Mechanical Engineering Department, College of Engineering, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
7
|
Horne J, Dunne N, Singh N, Safiuddin M, Esmaeili N, Erenler M, Ho I, Luk E. Building parameters linked with indoor transmission of SARS-CoV-2. ENVIRONMENTAL RESEARCH 2023; 238:117156. [PMID: 37717799 DOI: 10.1016/j.envres.2023.117156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 07/27/2023] [Accepted: 09/14/2023] [Indexed: 09/19/2023]
Abstract
The rapid spread of Coronavirus Disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has emphasized the importance of understanding and adapting to the indoor remediation of transmissible diseases to decrease the risk for future pandemic threats. While there were many precautions in place to hinder the spread of COVID-19, there has also been a substantial increase of new research on SARS-CoV-2 that can be utilized to further mitigate the transmission risk of this novel virus. This review paper aims to identify the building parameters of indoor spaces that could have considerable influence on the transmission of SARS-CoV-2. The following building parameters have been identified and analyzed, emphasizing their link with the indoor transmission of SARS-CoV-2: temperature and relative humidity, temperature differences between rooms, ventilation rate and access to natural ventilation, occupant density, surface type and finish, airflow direction and speed, air stability, indoor air pollution, central air conditioning systems, capacity of air handling system and HVAC filter efficiency, edge sealing of air filters, room layout and interior design, and compartmentalization of interior space. This paper also explains the interactions of SARS-CoV-2 with indoor environments and its persistence. Furthermore, the modifications of the key building parameters have been discussed for controlling the transmission of SARS-CoV-2 in indoor spaces. Understanding the information provided in this paper is crucial to develop effective health and safety measures that will aid in infection prevention.
Collapse
Affiliation(s)
- Jacqueline Horne
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada
| | - Nicholas Dunne
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada
| | - Nirmala Singh
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada
| | - Md Safiuddin
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada.
| | - Navid Esmaeili
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada
| | - Merve Erenler
- Centre for Construction and Engineering Technologies, George Brown College, Casa Loma Campus, 160 Kendal Avenue, Toronto, ON M5R 1M3, Canada
| | - Ian Ho
- Sysconverge Inc., 7030 Woodbine Avenue, Suite 500, Markham, ON L3R 6G2, Canada
| | - Edwin Luk
- Sysconverge Inc., 7030 Woodbine Avenue, Suite 500, Markham, ON L3R 6G2, Canada
| |
Collapse
|
8
|
Saadatjoo P, Badamchizadeh P, Mahdavinejad M. Towards the new generation of courtyard buildings as a healthy living concept for post-pandemic era. SUSTAINABLE CITIES AND SOCIETY 2023; 97:104726. [PMID: 37360283 PMCID: PMC10284431 DOI: 10.1016/j.scs.2023.104726] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/31/2023] [Accepted: 06/11/2023] [Indexed: 06/28/2023]
Abstract
COVID-19 has laid a context for holistic research and practical approaches towards health issues in buildings. This study focuses on one particular residential building type, which is a combination of a modern apartment building with private double-oriented terraces, and a traditional courtyard building. This principle improves several aspects of healthy buildings and contributes to address indoor-outdoor interactions, daylighting, and the use of natural ventilation. The purpose of this study is to determine the factors underlying a particular type of semi-outdoor space within building forms and to explain their microclimatic behavior in buildings. One solid model and twelve porous apartment buildings with different numbers of porous sides, and terrace widths are evaluated using computational fluid dynamics. The k-ε turbulence model is adapted to simulate airflow in and around a four-story building. CFD simulations were validated against the wind-tunnel measurements. Investigations indicated that increasing the number of porous sides reduces the internal mean and maximum ages of air by -15.75 and -36.84%, which means improved ventilation performance. However, it leaves a negative trace on ventilation of the semi-outdoor spaces. Meanwhile, increasing the width of the terraces enhances the ventilation performance by reducing the mean age of air in units, courtyards, and terraces by -20%, -20%, and -9%, respectively.
Collapse
Affiliation(s)
- Paria Saadatjoo
- Department of Architecture, Faculty of Civil Engineering, University of Tabriz, Tabriz, Iran
| | - Parinaz Badamchizadeh
- Department of Architecture, Faculty of Civil Engineering, University of Tabriz, Tabriz, Iran
| | | |
Collapse
|
9
|
Ferrari S, Blázquez T, Cardelli R, De Angelis E, Puglisi G, Escandón R, Suárez R. Air change rates and infection risk in school environments: Monitoring naturally ventilated classrooms in a northern Italian urban context. Heliyon 2023; 9:e19120. [PMID: 37809762 PMCID: PMC10558299 DOI: 10.1016/j.heliyon.2023.e19120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 08/08/2023] [Accepted: 08/11/2023] [Indexed: 10/10/2023] Open
Abstract
The importance of building ventilation in avoiding long-distance airborne transmission has been highlighted with the advent of the COVID-19 pandemics. Among others, school environments, in particular classrooms, present criticalities in the implementation of ventilation strategies and their impact on indoor air quality and risk of contagion. In this work, three naturally ventilated school buildings located in northern Italy have undergone monitoring at the end of the heating season. Environmental parameters, such as CO2 concentration and indoor/outdoor air temperature, have been recorded together with the window opening configurations to develop a two-fold analysis: i) the estimation of real air change rates through the transient mass balance equation method, and ii) the individual infection risk via the Wells-Riley equation. A strong statistical correlation has been found between the air change rates and the windows opening configuration by means of a window-to-volume ratio between the total opening area and the volume of the classroom, which has been used to estimate the individual infection risk. Results show that the European Standard recommendation for air renewal could be achieved by a window opening area of at least 1.5 m2, in the most prevailing Italian classrooms. Furthermore, scenarios in which the infector agent is a teacher show higher individual infection risk than those in which the infector is a student. In addition, the outcomes serve school staff as a reference to ensure adequate ventilation in classrooms and keep the risk of infection under control based on the number of the students and the volume of the classroom.
Collapse
Affiliation(s)
- S. Ferrari
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - T. Blázquez
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - R. Cardelli
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - E. De Angelis
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - G. Puglisi
- Dept. of Energy Efficiency Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - R. Escandón
- Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Sevilla, Spain
| | - R. Suárez
- Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Sevilla, Spain
| |
Collapse
|
10
|
Kong M, Kim H, Hong T. An effective alerting strategy to facilitate occupants' perception of indoor air quality: By alarming concentration of indoor air pollution. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 325:121428. [PMID: 36914153 DOI: 10.1016/j.envpol.2023.121428] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 01/27/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
Previous studies have proven that it is hard for occupants to perceive concentration of indoor air pollution (IAP) and resulting indoor air quality (IAQ) on their own. Therefore, a method is needed to encourage them to turn their attention to actual IAP, in this context, alerting is thus suggested. However, previous studies pose limitations in that they failed to analyze the effects of alerting concentration of IAP on occupants' IAQ perception. To fill the research gap, this study sought to explore a proper strategy to help occupants have a clearer perception of IAQ. A one-month observational experiment was conducted on nine subjects under three scenarios with different alerting strategies. In addition, the visual distance estimation method was used to quantitatively analyze similar tendencies between the subject's perceived IAQ and concentration of IAP for each scenario. The experimental results confirmed that when an alerting notification was not sent, the occupants could not clearly perceive IAQ as the visual distance was the highest at 0.332. On the other hand, when the alerting notification whether the concentration of IAP exceeded the standard or not was sent, the occupants could perceive IAQ relatively clearly as the visual distance was reduced to 0.291 and 0.236. In conclusion, not only installing a monitoring device but also establishing proper alerting strategies on the concentration of IAP is essential to facilitate occupants' IAQ perception and protect occupants' health.
Collapse
Affiliation(s)
- Minjin Kong
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul, South Korea
| | - Hakpyeong Kim
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul, South Korea
| | - Taehoon Hong
- Department of Architecture and Architectural Engineering, Yonsei University, Seoul, South Korea.
| |
Collapse
|
11
|
Richard A, Bruat C, Febvrel D, Squinazi F, Simos J, Zmirou-Navier D. Creation and testing of the Domiscore-a tool to characterize the impact of housing on health and well-being. BMC Public Health 2023; 23:815. [PMID: 37143018 PMCID: PMC10157125 DOI: 10.1186/s12889-023-15451-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 03/15/2023] [Indexed: 05/06/2023] Open
Abstract
BACKGROUND Despite evidence of the major impact housing carries on health, many individuals still live in unhealthy dwellings. In France, the Domiscore has been proposed as a tool to assess the quality of dwellings with regard to their health impact, to allow for a better detection of unsafe housing and to improve dwellings. The aim of this paper is to present the method used to construct the Domiscore and test its relevance and usability. METHODS The Domiscore grid, inspired by the Nutriscore, consists of 46 variables-such as air quality, light or outdoor view. Each variable is scored on a four-point scale using in situ observation, mandatory diagnostics and open access data. The sum of each variable's score results in an overall risk score for the dwelling. The Domiscore was tested in two phases. During the first testing phase, 11 real estate professionals, health professionals and social workers used the Domiscore for on-site visits in different geographic areas of France. They then participated in a semi-structured qualitative interview. The second phase consisted in a public consultation with diverse stakeholders such as public authorities, housing activists and social workers, using an online survey to collect their opinions on the Domiscore's relevance, understandability and usability. RESULTS The Domiscore was tested on 28 homes. Variables completion rates were high irrespective of tester profile for all home visits (91%, SD = 4.7%). The mean time needed to fill in the grid was 1.5 h. The public consultation returned 151 responses. The Domiscore was deemed easy to understand, relevant, and rather easy to fill out. Most participants found the Domiscore useful for information gathering, awareness raising, detecting at-risk situations and agreed that it could contribute to enhance housing conditions. Its length was noted, although the inclusion of additional variables was also suggested. CONCLUSIONS The results of this study suggest that the Domiscore is accessible to housing specialists and other professionals for the evaluation of a dwelling's health impacts and the standardized detection of dangerous situations. The testing process allowed for improvements in the grid and training materials for future users.
Collapse
Affiliation(s)
- Aude Richard
- Institute of Global Health, University of Geneva, Geneva, Switzerland
| | - Camille Bruat
- HCSP (High Council of Public Health), Paris, France.
| | | | | | - Jean Simos
- Institute of Global Health, University of Geneva, Geneva, Switzerland
- HCSP (High Council of Public Health), Paris, France
| | - Denis Zmirou-Navier
- HCSP (High Council of Public Health), Paris, France
- Université de Lorraine, Nancy, France
| |
Collapse
|
12
|
Lyu X, Luo Z, Shao L, Awbi H, Lo Piano S. Safe CO 2 threshold limits for indoor long-range airborne transmission control of COVID-19. BUILDING AND ENVIRONMENT 2023; 234:109967. [PMID: 36597420 PMCID: PMC9801696 DOI: 10.1016/j.buildenv.2022.109967] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/16/2022] [Accepted: 12/29/2022] [Indexed: 06/17/2023]
Abstract
CO2-based infection risk monitoring is highly recommended during the current COVID-19 pandemic. However, the CO2 monitoring thresholds proposed in the literature are mainly for spaces with fixed occupants. Determining CO2 threshold is challenging in spaces with changing occupancy due to the co-existence of quanta and CO2 remaining from previous occupants. Here, we propose a new calculation framework for deriving safe excess CO2 thresholds (above outdoor level), C t, for various spaces with fixed/changing occupancy and analyze the uncertainty involved. We categorized common indoor spaces into three scenarios based on their occupancy conditions, e.g., fixed or varying infection ratios (infectors/occupants). We proved that the rebreathed fraction-based model can be applied directly for deriving C t in the case of a fixed infection ratio (Scenario 1 and Scenario 2). In the case of varying infection ratios (Scenario 3), C t derivation must follow the general calculation framework due to the existence of initial quanta/excess CO2. Otherwise, C t can be significantly biased (e.g., 260 ppm) when the infection ratio varies greatly. C t can vary significantly based on specific space factors such as occupant number, physical activity, and community prevalence, e.g., 7 ppm for gym and 890 ppm for lecture hall, indicating C t must be determined on a case-by-case basis. An uncertainty of up to 6 orders of magnitude for C t was found for all cases due to uncertainty in emissions of quanta and CO2, thus emphasizing the role of accurate emissions data in determining C t.
Collapse
Affiliation(s)
- Xiaowei Lyu
- School of the Built Environment, University of Reading, UK
| | - Zhiwen Luo
- Welsh School of Architecture, Cardiff University, UK
| | - Li Shao
- School of the Built Environment, University of Reading, UK
| | - Hazim Awbi
- School of the Built Environment, University of Reading, UK
| | | |
Collapse
|
13
|
A review on indoor airborne transmission of COVID-19– modelling and mitigation approaches. JOURNAL OF BUILDING ENGINEERING 2023; 64:105599. [PMCID: PMC9699823 DOI: 10.1016/j.jobe.2022.105599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/11/2022] [Accepted: 11/21/2022] [Indexed: 06/09/2023]
Abstract
In the past few years, significant efforts have been made to investigate the transmission of COVID-19. This paper provides a review of the COVID-19 airborne transmission modeling and mitigation strategies. The simulation models here are classified into airborne transmission infectious risk models and numerical approaches for spatiotemporal airborne transmissions. Mathematical descriptions and assumptions on which these models have been based are discussed. Input data used in previous simulation studies to assess the dispersion of COVID-19 are extracted and reported. Moreover, measurements performed to study the COVID-19 airborne transmission within indoor environments are introduced to support validations for anticipated future modeling studies. Transmission mitigation strategies recommended in recent studies have been classified to include modifying occupancy and ventilation operations, using filters and air purifiers, installing ultraviolet (UV) air disinfection systems, and personal protection compliance, such as wearing masks and social distancing. The application of mitigation strategies to various building types, such as educational, office, public, residential, and hospital, is reviewed. Recommendations for future works are also discussed based on the current apparent knowledge gaps covering both modeling and mitigation approaches. Our findings show that different transmission mitigation measures were recommended for various indoor environments; however, there is no conclusive work reporting their combined effects on the level of mitigation that may be achieved. Moreover, further studies should be conducted to understand better the balance between approaches to mitigating the viral transmissions in buildings and building energy consumption.
Collapse
|
14
|
Choi J, Poudel K, Nam KS, Piri A, Rivera-Piza A, Ku SK, Hwang J, Kim JO, Byeon JH. Aero-manufacture of nanobulges for an in-place anticoronaviral on air filters. JOURNAL OF HAZARDOUS MATERIALS 2023; 445:130458. [PMID: 36444810 DOI: 10.1016/j.jhazmat.2022.130458] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/09/2022] [Accepted: 11/20/2022] [Indexed: 06/16/2023]
Abstract
The interest in removing contagious viruses from indoor air using ventilation and filtration systems is increasing rapidly because people spend most of the day indoors. The development of an effective platform to regenerate the antiviral function of air filters during use and safe abrogation of used filters containing infectious viruses is a challenging task, because an on-demand safe-by-design manufacture system is essential for in-place antiviral coatings, but it has been rarely investigated. With these considerations, an electrically operable dispenser was prepared for decorating continuous ultrafine Fe-Zn, Fe-Ag, or Fe-Cu particles (<5 nm) onto SiO2 nanobeads (ca. 130 nm) to form nanobulges (i.e., nanoroughness for engaging coronavirus spikes) in the aerosol state for 3 min direct deposition on the air filter surfaces. The resulting nanobulges were exposed to human coronaviruses (HCoV; surrogates of SARS-CoV-2) to assess antiviral function. The results were compared with similar-sized individual Zn, Ag, and Cu particles. The nanobulges exhibited comparable antiviral activity to Zn, Ag, and Cu particles while retaining biosafety in both in vitro and in vivo models because of the significantly smaller metallic fractions. This suggests that the bimetallic bulge structures generate reactive oxygen species and Fenton-mediated hydroxyl radicals for inactivating HCoV.
Collapse
Affiliation(s)
- Jisoo Choi
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Kishwor Poudel
- College of Pharmacy, Yeungnam University, Gyeongsan 38511, Republic of Korea; Wellman Center for Photomedicine, Department of Dermatology, Meassachusetts General Hospital, Harvard Medical School, MA 02114, USA
| | - Kang Sik Nam
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Amin Piri
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Adriana Rivera-Piza
- Department of Biotechnology, Korea University, Seoul 02841, Republic of Korea
| | - Sae Kwang Ku
- College of Korean Medicine, Daegu Haany University, Gyeongsan 38610 Republic of Korea
| | - Jungho Hwang
- School of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.
| | - Jong Oh Kim
- College of Pharmacy, Yeungnam University, Gyeongsan 38511, Republic of Korea.
| | - Jeong Hoon Byeon
- School of Mechanical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.
| |
Collapse
|
15
|
Systematic Review of the Key Factors Influencing the Indoor Airborne Spread of SARS-CoV-2. Pathogens 2023; 12:pathogens12030382. [PMID: 36986304 PMCID: PMC10053454 DOI: 10.3390/pathogens12030382] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 02/19/2023] [Accepted: 02/20/2023] [Indexed: 03/06/2023] Open
Abstract
The COVID-19 pandemic due to the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has been plaguing the world since late 2019/early 2020 and has changed the way we function as a society, halting both economic and social activities worldwide. Classrooms, offices, restaurants, public transport, and other enclosed spaces that typically gather large groups of people indoors, and are considered focal points for the spread of the virus. For society to be able to go “back to normal”, it is crucial to keep these places open and functioning. An understanding of the transmission modes occurring in these contexts is essential to set up effective infection control strategies. This understanding was made using a systematic review, according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses statement (PRISMA) 2020 guidelines. We analyze the different parameters influencing airborne transmission indoors, the mathematical models proposed to understand it, and discuss how we can act on these parameters. Methods to judge infection risks through the analysis of the indoor air quality are described. Various mitigation measures are listed, and their efficiency, feasibility, and acceptability are ranked by a panel of experts in the field. Thus, effective ventilation procedures controlled by CO2-monitoring, continued mask wearing, and a strategic control of room occupancy, among other measures, are put forth to enable a safe return to these essential places.
Collapse
|
16
|
Jendrossek SN, Jurk LA, Remmers K, Cetin YE, Sunder W, Kriegel M, Gastmeier P. The Influence of Ventilation Measures on the Airborne Risk of Infection in Schools: A Scoping Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3746. [PMID: 36834438 PMCID: PMC9961295 DOI: 10.3390/ijerph20043746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 02/15/2023] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVES To review the risk of airborne infections in schools and evaluate the effect of intervention measures reported in field studies. BACKGROUND Schools are part of a country's critical infrastructure. Good infection prevention measures are essential for reducing the risk of infection in schools as much as possible, since these are places where many individuals spend a great deal of time together every weekday in a small area where airborne pathogens can spread quickly. Appropriate ventilation can reduce the indoor concentration of airborne pathogens and reduce the risk of infection. METHODS A systematic search of the literature was conducted in the databases Embase, MEDLINE, and ScienceDirect using keywords such as school, classroom, ventilation, carbon dioxide (CO2) concentration, SARS-CoV-2, and airborne transmission. The primary endpoint of the studies selected was the risk of airborne infection or CO2 concentration as a surrogate parameter. Studies were grouped according to the study type. RESULTS We identified 30 studies that met the inclusion criteria, six of them intervention studies. When specific ventilation strategies were lacking in schools being investigated, CO2 concentrations were often above the recommended maximum values. Improving ventilation lowered the CO2 concentration, resulting in a lower risk of airborne infections. CONCLUSIONS The ventilation in many schools is not adequate to guarantee good indoor air quality. Ventilation is an important measure for reducing the risk of airborne infections in schools. The most important effect is to reduce the time of residence of pathogens in the classrooms.
Collapse
Affiliation(s)
- Sandra N. Jendrossek
- Institute of Hygiene and Environmental Medicine, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany
| | - Lukas A. Jurk
- Institute of Industrial Building and Construction Design, Technical University Carolo Wilhelmina, 38106 Braunschweig, Germany
| | - Kirsten Remmers
- Institute of Industrial Building and Construction Design, Technical University Carolo Wilhelmina, 38106 Braunschweig, Germany
| | - Yunus E. Cetin
- Hermann-Rietschel-Institut, Technical University of Berlin, 10623 Berlin, Germany
| | - Wolfgang Sunder
- Institute of Industrial Building and Construction Design, Technical University Carolo Wilhelmina, 38106 Braunschweig, Germany
| | - Martin Kriegel
- Hermann-Rietschel-Institut, Technical University of Berlin, 10623 Berlin, Germany
| | - Petra Gastmeier
- Institute of Hygiene and Environmental Medicine, Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 12203 Berlin, Germany
| |
Collapse
|
17
|
Aganovic A, Cao G, Kurnitski J, Wargocki P. New dose-response model and SARS-CoV-2 quanta emission rates for calculating the long-range airborne infection risk. BUILDING AND ENVIRONMENT 2023; 228:109924. [PMID: 36531865 PMCID: PMC9747236 DOI: 10.1016/j.buildenv.2022.109924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/12/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
Predictive models for airborne infection risk have been extensively used during the pandemic, but there is yet still no consensus on a common approach, which may create misinterpretation of results among public health experts and engineers designing building ventilation. In this study we applied the latest data on viral load, aerosol droplet sizes and removal mechanisms to improve the Wells Riley model by introducing the following novelties i) a new model to calculate the total volume of respiratory fluid exhaled per unit time ii) developing a novel viral dose-based generation rate model for dehydrated droplets after expiration iii) deriving a novel quanta-RNA relationship for various strains of SARS-CoV-2 iv) proposing a method to account for the incomplete mixing conditions. These new approaches considerably changed previous estimates and allowed to determine more accurate average quanta emission rates including omicron variant. These quanta values for the original strain of 0.13 and 3.8 quanta/h for breathing and speaking and the virus variant multipliers may be used for simple hand calculations of probability of infection or with developed model operating with six size ranges of aerosol droplets to calculate the effect of ventilation and other removal mechanisms. The model developed is made available as an open-source tool.
Collapse
Affiliation(s)
- Amar Aganovic
- Department of Automation and Process Engineering, UiT The Arctic University of Norway, Tromsø, Norway
| | - Guangyu Cao
- Department of Energy and Process Engineering, Norwegian University of Science and Technology - NTNU, Trondheim, Norway
| | - Jarek Kurnitski
- REHVA Technology and Research Committee, Tallinn University of Technology, Tallinn, Estonia
| | - Pawel Wargocki
- Department of Civil Engineering, Technical University of Denmark, Copenhagen, Denmark
| |
Collapse
|
18
|
Zhang M, King MD. Temporal Variation of SARS-CoV-2 Levels in Wastewater from a Meat Processing Plant. Microorganisms 2023; 11:microorganisms11010174. [PMID: 36677465 PMCID: PMC9864470 DOI: 10.3390/microorganisms11010174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/04/2023] [Accepted: 01/07/2023] [Indexed: 01/12/2023] Open
Abstract
Wastewater-based surveillance (WBS) on SARS-CoV-2 has been proved to be an effective approach to estimate the prevalence of COVID-19 in communities and cities. However, its application was overlooked at smaller scale, such as a single facility. Meat processing plants are hotspots for COVID-19 outbreaks due to their unique environment that are favorable for the survival and persistence of SARS-CoV-2. This is the first known WBS study in meat processing plants. The goal was to understand the temporal variation of the SARS-CoV-2 levels in wastewater from a meat processing plant in Canada during a three-month campaign and to find any correlation with clinically confirmed cases in the surrounding city area. Higher SARS-CoV-2 concentrations and detection frequencies were observed in the solid fraction compared to the liquid fraction of the wastewater. The viruses can be preserved in the solid fraction of wastewater for up to 12 days. The wastewater virus level did not correlate to the city-wide COVID-19 cases due to the unmatching scales. WBS on SARS-CoV-2 in meat processing plants can be useful for identifying COVID-19 outbreaks in the facility and serve as an effective alternative when resources for routine individual testing are not available.
Collapse
|
19
|
Lu YH, Wu H, Zhang HH, Li WS, Lai ACK. Synergistic disinfection of aerosolized bacteria and bacteriophage by far-UVC (222-nm) and negative air ions. JOURNAL OF HAZARDOUS MATERIALS 2023; 441:129876. [PMID: 36087531 DOI: 10.1016/j.jhazmat.2022.129876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/22/2022] [Accepted: 08/28/2022] [Indexed: 06/15/2023]
Abstract
Air ionizers and 222-nm krypton-chlorine (KrCl) excilamp have proven to be effective disinfection apparatus for bacteria and viruses with limited health risks. We determined inactivation efficiencies by operating them individually and in combined modules. Gram-positive and gram-negative bacteria, non-enveloped dsDNA virus, and enveloped dsRNA virus were examined in a designed air disinfection system. Our results showed that the bioaerosols were inactivated efficiently by negative ionizers and far-UVC (222-nm), either used individually or in combination. Among which the combined modules of negative ionizers and KrCl excilamp had the best disinfection performance for the bacteria. The aerosolized virus P22 and Phi 6 were more susceptible to 222-nm emitted by KrCl excilamp than negative air ions. Significant greater inactivation of bacterial bioaerosols were identified after treated by combined treatment of negative air ion and far-UVC for 2 minutes (Escherichia coli, 6.25 natural log (ln) reduction; Staphylococcus epidermidis, 3.66 ln reduction), as compared to the mean sum value of inactivation results by respective individual treatment of negative ionizers and KrCl excilamp (Escherichia coli, 4.34 ln; Staphylococcus epidermidis, 1.75 ln), indicating a synergistic inactivation effect. The findings provide important baseline data to support the design and development of safe and high-efficient disinfection systems.
Collapse
Affiliation(s)
- Y H Lu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - H Wu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China; Department of Biology, Hong Kong Baptist University, Kowloon, Hong Kong China
| | - H H Zhang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - W S Li
- School of Public Health, The University of Hong Kong, Pokfulam, Hong Kong China
| | - A C K Lai
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China.
| |
Collapse
|
20
|
Herbig B, Norrefeldt V, Mayer F, Reichherzer A, Lei F, Wargocki P. Effects of increased recirculation air rate and aircraft cabin occupancy on passengers' health and well-being - Results from a randomized controlled trial. ENVIRONMENTAL RESEARCH 2023; 216:114770. [PMID: 36370817 PMCID: PMC9760572 DOI: 10.1016/j.envres.2022.114770] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 10/28/2022] [Accepted: 11/07/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND Aircraft cabins are special environments. Passengers sit in close proximity in a space with low pressure that they cannot leave. The cabin is ventilated with a mixture of outside and recirculated air. The volume of outside air impacts the carbon footprint of flying. Higher recirculation air rates could be considered to save energy and divert less kerosene from producing thrust. OBJECTIVES To investigate whether higher recirculation air rates in aircraft cabins negatively affect passengers' health and well-being and if occupancy plays a role in this. METHODS In a 2 (occupancy: full and half-occupied) X 4 (ventilation regime) factorial design with stratified randomization, participants were exposed in an aircraft segment in a low-pressure tube during a 4-h simulated flight. Ventilation regimes consisted of increasing proportions of recirculated air up to a maximum CO2 concentration of 4200 ppm. Participants rated comfort, health symptoms, and sleepiness multiple times. Heart rate (variability), as stress marker, was measured continuously. RESULTS 559 persons representative of flight passengers regarding age (M = 42.7, SD = 15.9) and sex (283 men) participated. ANCOVA results showed hardly any effect of both factors on self-reported health symptoms, strong main effects of occupancy on comfort measures, and interaction effects for sleepiness and physiological stress parameters: Participants in the half-occupied cabin hardly reacted to increased recirculation air rates and show overall more favorable responses. Participants in the fully occupied cabin reported higher sleepiness and had stress reactions when the recirculation air rate was high. DISCUSSION This large-scale RCT shows the importance of occupancy, a previously neglected factor in indoor air research. The proximity of other people seems to increase stress and exacerbate reactions to air quality. Further studies on causal pathways are needed to determine if recirculation air rates can be increased to reduce the carbon footprint of flying without detrimental effects on passengers.
Collapse
Affiliation(s)
- Britta Herbig
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Germany.
| | - Victor Norrefeldt
- Fraunhofer Institute for Building Physics IBP, Holzkirchen Branch, Germany
| | - Florian Mayer
- Fraunhofer Institute for Building Physics IBP, Holzkirchen Branch, Germany
| | - Anna Reichherzer
- Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Germany
| | - Fang Lei
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kgs. Lyngby, Denmark
| |
Collapse
|
21
|
Hu CP, Cheng JH. Challenges and Actions of IAQ under COVID-19: A Survey of Taiwanese People's Perception of Epidemic Prevention and Indoor Places Certification. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:14942. [PMID: 36429667 PMCID: PMC9690431 DOI: 10.3390/ijerph192214942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 11/01/2022] [Accepted: 11/09/2022] [Indexed: 06/16/2023]
Abstract
COVID-19 is still spreading around the world, and the pandemic has awakened the public's attention to environmental cleanliness. This article used an online survey for people living in Taiwan, and a total of 1206 valid questionnaires were collected in October 2021. According to the survey results of Taiwanese people's awareness of and needs for epidemic prevention and IAQ, 94.4% of the respondents agreed that maintaining IAQ during the COVID-19 pandemic is very important for prevention. In addition, 95.4% of them also pointed out that the "Clean and Safe" mark certification should be promoted in public places. Finally, this article also uses hierarchical regression to analyze public perceptions of seven indoor places, including elevators, restaurants, dwellings, offices, gyms, kindergartens, and long-term care centers. The results found that: (1) from the perspective of epidemic prevention, improving IAQ through ventilation strategies could prevent the spread of the COVID-19 pandemic, and (2) from the perspective of promotion certification, the elevators, restaurants and offices could establish strengthened IAQ, dwellings, gyms and long-term care centers should emphasize the display of IAQ information in entrances and exits, and kindergartens should focus on increasing safety and reducing infection.
Collapse
Affiliation(s)
- Chih-Pei Hu
- Department of Public Administration, Chung Hua University, Hsinchu 30012, Taiwan
| | - Jen-Hsiung Cheng
- Taiwan Indoor Environment Quality Management Association, New Taipei City 23555, Taiwan
| |
Collapse
|
22
|
Nair AN, Anand P, George A, Mondal N. A review of strategies and their effectiveness in reducing indoor airborne transmission and improving indoor air quality. ENVIRONMENTAL RESEARCH 2022; 213:113579. [PMID: 35714688 PMCID: PMC9192357 DOI: 10.1016/j.envres.2022.113579] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 04/25/2022] [Accepted: 05/26/2022] [Indexed: 06/15/2023]
Abstract
Airborne transmission arises through the inhalation of aerosol droplets exhaled by an infected person and is now thought to be the primary transmission route of COVID-19. Thus, maintaining adequate indoor air quality levels is vital in mitigating the spread of the airborne virus. The cause-and-effect flow of various agents involved in airborne transmission of viruses has been investigated through a systematic literature review. It has been identified that the airborne virus can stay infectious in the air for hours, and pollutants such as particulate matter (PM10, PM2.5), Nitrogen dioxide (NO2), Sulphur dioxide (SO2), Carbon monoxide (CO), Ozone (O3), Carbon dioxide (CO2), and Total Volatile Organic Compounds (TVOCs) and other air pollutants can enhance the incidence, spread and mortality rates of viral disease. Also, environmental quality parameters such as humidity and temperature have shown considerable influence in virus transmission in indoor spaces. The measures adopted in different research studies that can curb airborne transmission of viruses for an improved Indoor Air Quality (IAQ) have been collated for their effectiveness and limitations. A diverse set of building strategies, components, and operation techniques from the recent literature pertaining to the ongoing spread of COVID-19 disease has been systematically presented to understand the current state of techniques and building systems that can minimize the viral spread in built spaces This comprehensive review will help architects, builders, realtors, and other organizations improve or design a resilient building system to deal with COVID-19 or any such pandemic in the future.
Collapse
Affiliation(s)
- Ajith N Nair
- Department of Architecture and Regional Planning, IIT, Kharagpur, India
| | - Prashant Anand
- Department of Architecture and Regional Planning, IIT, Kharagpur, India.
| | - Abraham George
- Department of Architecture and Regional Planning, IIT, Kharagpur, India
| | - Nilabhra Mondal
- Department of Architecture and Regional Planning, IIT, Kharagpur, India
| |
Collapse
|
23
|
Barone G, Buonomano A, Forzano C, Giuzio GF, Palombo A. Energy, economic, and environmental impacts of enhanced ventilation strategies on railway coaches to reduce Covid-19 contagion risks. ENERGY (OXFORD, ENGLAND) 2022; 256:124466. [PMID: 35754761 PMCID: PMC9212767 DOI: 10.1016/j.energy.2022.124466] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 05/04/2022] [Accepted: 06/03/2022] [Indexed: 06/15/2023]
Abstract
In the last years, the Covid-19 outbreak raised great awareness about ventilation system performance in confined spaces. Specifically, the heating, ventilation, and air conditioning system design and operating parameters, such as air change per hour, air recirculation ratio, filtration device performance, and vents location, play a crucial role in reducing the spread of viruses, moulds, bacteria, and general pollutants. Concerning the transport sector, due to the impracticability of social distancing, and the relatively loose requirements of ventilation standards, the SARS-COV-19 outbreak brought a reduction of payload (up to 50%) for different carriers. Specifically, this has been particularly severe for the railway sector, where train coaches are typically characterized by relatively elevated occupancy and high recirculation ratios. In this framework, to improve the Indoor Air Quality and reduce the Covid-19 contagion risk in railway carriages, the present paper investigates the energy, economic and environmental feasibility of diverse ventilation strategies. To do so, a novel dynamic simulation tool for the complete dynamic performance investigation of trains was developed in an OpenStudio environment. To assess the Covid-19 contagion risk connected to the investigated scenarios, the Wells-Riley model has been adopted. To prove the proposed approach's capabilities and show the Covid-19 infection risk reduction potentially achievable by varying the adopted ventilation strategies, a suitable case study related to an existing medium-distance train operating in South/Central Italy is presented. The conducted numerical simulations return interesting results providing also useful design criteria.
Collapse
Affiliation(s)
- Giovanni Barone
- Department of Industrial Engineering, University of Naples Federico II, Naples, Italy
| | - Annamaria Buonomano
- Department of Industrial Engineering, University of Naples Federico II, Naples, Italy
- Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, Canada
| | - Cesare Forzano
- Department of Industrial Engineering, University of Naples Federico II, Naples, Italy
| | | | - Adolfo Palombo
- Department of Industrial Engineering, University of Naples Federico II, Naples, Italy
| |
Collapse
|
24
|
Vaccinomics to Design a Multiepitope Vaccine against Legionella pneumophila. BIOMED RESEARCH INTERNATIONAL 2022; 2022:4975721. [PMID: 36164443 PMCID: PMC9509222 DOI: 10.1155/2022/4975721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 07/29/2022] [Accepted: 08/16/2022] [Indexed: 11/18/2022]
Abstract
Legionella pneumophila is found in the natural aquatic environment and can resist a wide range of environmental conditions. There are around fifty species of Legionella, at least twenty-four of which are directly linked to infections in humans. L. pneumophila is the cause of Legionnaires' disease, a potentially lethal form of pneumonia. By blocking phagosome-lysosome fusion, L. pneumophila lives and proliferates inside macrophages. For this disease, there is presently no authorized multiepitope vaccine available. For the multi-epitope-based vaccine (MEBV), the best antigenic candidates were identified using immunoinformatics and subtractive proteomic techniques. Several immunoinformatics methods were utilized to predict B and T cell epitopes from vaccine candidate proteins. To construct an in silico vaccine, epitopes (07 CTL, 03 HTL, and 07 LBL) were carefully selected and docked with MHC molecules (MHC-I and MHC-II) and human TLR4 molecules. To increase the immunological response, the vaccine was combined with a 50S ribosomal adjuvant. To maximize vaccine protein expression, MEBV was cloned and reverse-translated in Escherichia coli. To prove the MEBV's efficacy, more experimental validation is required. After its development, the resulting vaccine is greatly hoped to aid in the prevention of L. pneumophila infections.
Collapse
|
25
|
Gartland N, Fishwick D, Coleman A, Davies K, Hartwig A, Johnson S, van Tongeren M. Transmission and control of SARS-CoV-2 on ground public transport: A rapid review of the literature up to May 2021. JOURNAL OF TRANSPORT & HEALTH 2022; 26:101356. [PMID: 35261878 PMCID: PMC8894738 DOI: 10.1016/j.jth.2022.101356] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 02/22/2022] [Accepted: 03/01/2022] [Indexed: 05/09/2023]
Abstract
BACKGROUND During a pandemic, public transport is strategically important for keeping the country going and getting people where they need to be. The essential nature of public transport puts into focus the risk of transmission of SARS-CoV-2 in this sector; rapid and diverse work has been done to attempt to understand how transmission happens in this context and what factors influence risk. OBJECTIVES This review aimed to provide a narrative overview of the literature assessing transmission, or potential for transmission, of SARS-CoV-2 on ground-based public transport, as well as studies assessing the effectiveness of control measures on public transport during the early part of the pandemic (up to May 2021). METHODS An electronic search was conducted using Web of Science, Ovid, the Cochrane Library, ProQuest, Pubmed, and the WHO global COVID database. Searches were run between December 2020 and May 2021. RESULTS The search strategy identified 734 papers, of which 28 papers met the inclusion criteria for the review; 10 papers assessed transmission of SARS-CoV-2, 11 assessed control measures, and seven assessed levels of contamination. Eleven papers were based on modelling approaches; 17 studies were original studies reporting empirical COVID-19 data. CONCLUSIONS The literature is heterogeneous, and there are challenges for measurement of transmission in this setting. There is evidence for transmission in certain cases, and mixed evidence for the presence of viral RNA in transport settings; there is also evidence for some reduction of risk through mitigation. However, the routes of transmission and key factors contributing to transmission of SARS-CoV-2 on public transport were not clear during the early stage of the pandemic. Gaps in understanding are discussed and six key questions for future research have been posed. Further exploration of transmission factors and effectiveness of mitigation strategies is required in order to support decision making.
Collapse
Affiliation(s)
- Nicola Gartland
- School of Health Sciences, University of Manchester, Manchester, United Kingdom
| | - David Fishwick
- School of Health Sciences, University of Manchester, Manchester, United Kingdom
| | - Anna Coleman
- School of Health Sciences, University of Manchester, Manchester, United Kingdom
| | - Karen Davies
- School of Health Sciences, University of Manchester, Manchester, United Kingdom
| | - Angelique Hartwig
- Alliance Manchester Business School, University of Manchester, Manchester, United Kingdom
| | - Sheena Johnson
- Alliance Manchester Business School, University of Manchester, Manchester, United Kingdom
| | - Martie van Tongeren
- School of Health Sciences, University of Manchester, Manchester, United Kingdom
| |
Collapse
|
26
|
Ferrari S, Blázquez T, Cardelli R, Puglisi G, Suárez R, Mazzarella L. Ventilation strategies to reduce airborne transmission of viruses in classrooms: A systematic review of scientific literature. BUILDING AND ENVIRONMENT 2022; 222:109366. [PMID: 35818484 PMCID: PMC9259197 DOI: 10.1016/j.buildenv.2022.109366] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 06/20/2022] [Accepted: 07/02/2022] [Indexed: 06/15/2023]
Abstract
The recent pandemic due to SARS-CoV-2 has brought to light the need for strategies to mitigate contagion between human beings. Apart from hygiene measures and social distancing, air ventilation highly prevents airborne transmission within enclosed spaces. Among others, educational environments become critical in strategic planning to control the spread of pathogens and viruses amongst the population, mainly in cold conditions. In the event of a virus outbreak - such as COVID or influenza - many school classrooms still lack the means to guarantee secure and healthy environments. The present review examines school contexts that implement air ventilation strategies to reduce the risk of contagion between students. The analysed articles present past experiences that use either natural or mechanical systems assessed through mathematical models, numerical models, or full-scale experiments. For naturally ventilated classrooms, the studies highlight the importance of the architectural design of educational spaces and propose strategies for aeration control such as CO2-based control and risk-infection control. When it comes to implementing mechanical ventilation in classrooms, different systems with different airflow patterns are assessed based on their ability to remove airborne pathogens considering parameters like the age of air and the generation of airflow streamlines. Moreover, studies report that programmed mechanical ventilation systems can reduce risk-infection during pandemic events. In addition to providing a systematic picture of scientific studies in the field, the findings of this review can be a valuable reference for school administrators and policymakers to implement the best strategies in their classroom settings towards reducing infection risks.
Collapse
Affiliation(s)
- S Ferrari
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - T Blázquez
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - R Cardelli
- Dept. of Architecture, Built Environment and Construction Engineering, Politecnico di Milano, Milano, Italy
| | - G Puglisi
- Dept. of Energy Efficiency Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Rome, Italy
| | - R Suárez
- Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Sevilla, Spain
| | - L Mazzarella
- Dept. of Energy, Politecnico di Milano, Milano, Italy
| |
Collapse
|
27
|
Zhang Y, Hui FKP, Duffield C, Saeed AM. A review of facilities management interventions to mitigate respiratory infections in existing buildings. BUILDING AND ENVIRONMENT 2022; 221:109347. [PMID: 35782231 PMCID: PMC9238148 DOI: 10.1016/j.buildenv.2022.109347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 05/01/2022] [Accepted: 06/23/2022] [Indexed: 06/15/2023]
Abstract
The Covid-19 pandemic reveals that the hazard of the respiratory virus was a secondary consideration in the design, development, construction, and management of public and commercial buildings. Retrofitting such buildings poses a significant challenge for building owners and facilities managers. This article reviews current research and practices in building operations interventions for indoor respiratory infection control from the perspective of facilities managers to assess the effectiveness of available solutions. This review systematically selects and synthesises eighty-six articles identified through the PRISMA process plus supplementary articles identified as part of the review process, that deal with facilities' operations and maintenance (O&M) interventions. The paper reviewed the context, interventions, mechanisms, and outcomes discussed in these articles, concluding that interventions for respiratory virus transmission in existing buildings fall into three categories under the Facilities Management (FM) discipline: Hard services (HVAC and drainage system controls) to prevent aerosol transmissions, Soft Services (cleaning and disinfection) to prevent fomite transmissions, and space management (space planning and occupancy controls) to eliminate droplet transmissions. Additionally, the research emphasised the need for FM intervention studies that examine occupant behaviours with integrated intervention results and guide FM intervention decision-making. This review expands the knowledge of FM for infection control and highlights future research opportunities.
Collapse
Affiliation(s)
- Yan Zhang
- Department of Infrastructure Engineering, University of Melbourne, Level 6, Building 290, 700 Swanston Street, Carlton, Victoria, Australia
| | - Felix Kin Peng Hui
- Department of Infrastructure Engineering, University of Melbourne, Australia
| | - Colin Duffield
- Department of Infrastructure Engineering, University of Melbourne, Australia
| | - Ali Mohammed Saeed
- Department of Jobs, Regions and Precincts, Level 13, 1 Spring Street, Melbourne, Victoria, Australia
| |
Collapse
|
28
|
Faulkner CA, Castellini JE, Lou Y, Zuo W, Lorenzetti DM, Sohn MD. Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings. BUILDING AND ENVIRONMENT 2022; 221:109282. [PMID: 35965917 PMCID: PMC9358780 DOI: 10.1016/j.buildenv.2022.109282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 06/01/2022] [Accepted: 06/08/2022] [Indexed: 05/29/2023]
Abstract
Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. A system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.
Collapse
Affiliation(s)
- Cary A Faulkner
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, 80309, CO, USA
| | - John E Castellini
- Department of Mechanical Engineering, University of Colorado Boulder, UCB 427, Boulder, 80309, CO, USA
| | - Yingli Lou
- Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, UCB 428, Boulder, 80309, CO, USA
| | - Wangda Zuo
- Department of Architectural Engineering, Pennsylvania State University, 104 Engineering Unit A, University Park, 16802, PA, USA
- National Renewable Energy National Laboratory, Golden, 80401, CO, USA
| | - David M Lorenzetti
- Energy Analysis and Environmental Impacts Division, Lawrence Berkeley, USA
| | - Michael D Sohn
- Energy Analysis and Environmental Impacts Division, Lawrence Berkeley, USA
| |
Collapse
|
29
|
Hu T, Ji Y, Fei F, Zhu M, Jin T, Xue P, Zhang N. Optimization of COVID-19 prevention and control with low building energy consumption. BUILDING AND ENVIRONMENT 2022; 219:109233. [PMID: 35664635 PMCID: PMC9148426 DOI: 10.1016/j.buildenv.2022.109233] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 05/20/2023]
Abstract
COVID-19 is a global threat. Non-pharmaceutical interventions were commonly adopted for COVID-19 prevention and control. However, during stable periods of the pandemic, energy would be inevitably wasted if all interventions were implemented. The study aims to reduce the building energy consumption when meet the demands of epidemic prevention and control under the stable period of COVID-19. Based on the improved Wells-Riley model considering dynamic quanta generation and pulmonary ventilation rate, we established the infection risk - equivalent fresh air volume - energy consumption model to analyze the infection risk and building energy consumption during different seasons and optimized the urban building energy consumption according to the spatio-temporal population distribution. Shopping centers and restaurants contributed the most in urban energy consumption, and if they are closed during the pandemic, the total infection risk would be reduced by 25%-40% and 15%-25% respectively and the urban energy consumption would be reduced by 30%-40% and 13%-20% respectively. If people wore masks in all public indoor environments (exclude restaurants and KTV), the infection risk could be reduced by 60%-70% and the energy consumption could be reduced by 20%-60%. Gyms pose the highest risk for COVID-19 transmission. If the energy consumption kept the same with the current value, after the optimization, infection risk in winter, summer and the transition season could be reduced by 65%, 53% and 60%, respectively. After the optimization, under the condition of R t < 1, the energy consumption in winter, summer, and the transition season could be reduced by 72%, 64%, and 68% respectively.
Collapse
Affiliation(s)
- Tingrui Hu
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Ying Ji
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Fan Fei
- College of Mechatronical and Electrical Engineering, Hebei Agricultural University, Hebei province, China
| | - Min Zhu
- 6th Medical Center of General Hospital of PLA, Beijing, China
| | - Tianyi Jin
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Peng Xue
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Nan Zhang
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| |
Collapse
|
30
|
Yan S, Wang LL, Birnkrant MJ, Zhai J, Miller SL. Evaluating SARS-CoV-2 airborne quanta transmission and exposure risk in a mechanically ventilated multizone office building. BUILDING AND ENVIRONMENT 2022; 219:109184. [PMID: 35602249 PMCID: PMC9102535 DOI: 10.1016/j.buildenv.2022.109184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 04/19/2022] [Accepted: 05/09/2022] [Indexed: 05/11/2023]
Abstract
The world has faced tremendous challenges during the COVID-19 pandemic since 2020, and effective clean air strategies that mitigate infectious risks indoors have become more essential. In this study, a novel approach based on the Wells-Riley model applied to a multizone building was proposed to simulate exposure to infectious doses in terms of "quanta". This modeling approach quantifies the relative benefits of different risk mitigation strategies so that their effectiveness could be compared. A case study for the US Department of Energy large office prototype building was conducted to illustrate the approach. The infectious risk propagation from the infection source throughout the building was evaluated. Different mitigation strategies were implemented, including increasing outdoor air ventilation rates and adding air-cleaning devices such as Minimum Efficiency Reporting Value (MERV) filters and portable air cleaners (PACs) with HEPA filters in-room/in-duct germicidal ultraviolet (GUV) lights, layering with wearing masks. Results showed that to keep the risk of the infection propagating low the best strategy without universal masking was the operation of in-room GUV or a large industrial-sized PAC; whereas with masking all strategies were acceptable. This study contributes to a better understanding of the airborne transmission risks in multizone, mechanically ventilated buildings and how to reduce infection risk from a public health perspective of different mitigation strategies.
Collapse
Affiliation(s)
- Shujie Yan
- Dept. of Building, Civil & Environmental Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montreal, Quebec, H3G1M8, Canada
| | - Liangzhu Leon Wang
- Dept. of Building, Civil & Environmental Engineering, Concordia University, 1455 de Maisonneuve Blvd. West, Montreal, Quebec, H3G1M8, Canada
| | | | - John Zhai
- Department of Civil, Environmental and Architectural Engineering, University of Colorado, Boulder, USA
| | - Shelly L Miller
- Department of Mechanical Engineering, University of Colorado, Boulder, USA
| |
Collapse
|
31
|
Izadyar N, Miller W. Ventilation strategies and design impacts on indoor airborne transmission: A review. BUILDING AND ENVIRONMENT 2022; 218:109158. [PMID: 35573806 PMCID: PMC9075988 DOI: 10.1016/j.buildenv.2022.109158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 04/26/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
The COVID-19 outbreak has brought the indoor airborne transmission issue to the forefront. Although ventilation systems provide clean air and dilute indoor contaminated air, there is strong evidence that airborne transmission is the main route for contamination spread. This review paper aims to critically investigate ventilation impacts on particle spread and identify efficient ventilation strategies in controlling aerosol distribution in clinical and non-clinical environments. This article also examines influential ventilation design features (i.e., exhaust location) affecting ventilation performance in preventing aerosols spread. This paper shortlisted published documents for a review based on identification (keywords), pre-processing, screening, and eligibility of these articles. The literature review emphasizes the importance of ventilation systems' design and demonstrates all strategies (i.e., mechanical ventilation) could efficiently remove particles if appropriately designed. The study highlights the need for occupant-based ventilation systems, such as personalized ventilation instead of central systems, to reduce cross-infections. The literature underlines critical impacts of design features like ventilation rates and the number and location of exhausts and suggests designing systems considering airborne transmission. This review underpins that a higher ventilation rate should not be regarded as a sole indicator for designing ventilation systems because it cannot guarantee reducing risks. Using filtration and decontamination devices based on building functionalities and particle sizes can also increase ventilation performance. This paper suggests future research on optimizing ventilation systems, particularly in high infection risk spaces such as multi-storey hotel quarantine facilities. This review contributes to adjusting ventilation facilities to control indoor aerosol transmission.
Collapse
Affiliation(s)
- Nima Izadyar
- School of Built Environment, College of Engineering and Science, Victoria University, Melbourne, VIC, Australia
| | - Wendy Miller
- School of Architecture & Built Environment, Science and Engineering Faculty, Queensland University of Technology (QUT), Brisbane, QLD, 4001, Australia
| |
Collapse
|
32
|
Andalib E, Faghani M, Zia Ziabari SM, Shenagari M, Salehiniya H, Keivanlou MH, Rafat Z. The Effectiveness of the Anteroom (Vestibule) Area on Hospital Infection Control and Health Staff Safety: A Systematic Review. Front Public Health 2022; 10:828845. [PMID: 35558527 PMCID: PMC9086672 DOI: 10.3389/fpubh.2022.828845] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 03/22/2022] [Indexed: 01/22/2023] Open
Abstract
The emergence of SARS-CoV2 in 2019 showed again that the world's healthcare system is not fully equipped and well-designed for preventing the transmission of nosocomial respiratory infections. One of the great tools for preventing the spread of infectious organisms in hospitals is the anteroom. Several articles have investigated the role of the anteroom in disease control but the lack of a comprehensive study in this field prompted us to provide more in-depth information to fill this gap. Also, this study aimed to assess the necessity to construct an anteroom area for hospital staff members at the entrance of each ward of the hospital, and specify the equipment and facilities which make the anteroom more efficient. Articles were identified through searches of Scopus, Web of Sciences, PubMed, and Embase for studies published in English until May 2020 reporting data on the effect of the anteroom (vestibule) area in controlling hospital infections. Data from eligible articles were extracted and presented according to PRISMA's evidence-based data evaluation search strategy. Also, details around the review aims and methods were registered with the PROSPERO. From the database, 209 articles were identified, of which 25 studies met the study criteria. Most studies demonstrated that an anteroom significantly enhances practical system efficiency. The results showed that the equipment such as ventilation system, high-efficiency particulate absorption filter, hand dispensers, alcohol-based disinfection, sink, mirror, transparent panel, UVC disinfection, and zone for PPE change, and parameters like temperature, door type, pressure, and size of the anteroom are factors that are effective on the safety of the hospital environment. Studies demonstrated that providing an anteroom for changing clothing and storing equipment may be useful in reducing the transmission of airborne infections in hospitals. Since the transmission route of SARS-CoV2 is common with other respiratory infectious agents, it can be concluded that a well-designed anteroom could potentially decrease the risk of SARS-CoV2 transmission during hospitalization as well.
Collapse
Affiliation(s)
- Elham Andalib
- Department of Design, Faculty of Fine Art, Music and Design, University of Bergen, Bergen, Norway.,Clinical Research Development Unit of Poursina Hospital, Guilan University of Medical Sciences, Rasht, Iran
| | - Masoumeh Faghani
- Department of Anatomy, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Seyyed Mahdi Zia Ziabari
- Department of Emergency Medicine, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Mohammad Shenagari
- Department of Medical Microbiology, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Hamid Salehiniya
- Social Determinants of Health Research Center, Birjand University of Medical Sciences, Birjand, Iran
| | | | - Zahra Rafat
- Department of Medical Microbiology, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
33
|
Gartland N, Coleman A, Fishwick D, Johnson S, Armitage CJ, van Tongeren M. Experiences, Perceptions of Risk, and Lasting Impacts of COVID-19 for Employees in the Public Transport Sector. Ann Work Expo Health 2022; 67:76-86. [PMID: 35567752 PMCID: PMC9129159 DOI: 10.1093/annweh/wxac030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 03/08/2022] [Accepted: 04/28/2022] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Age-standardized mortality rates for taxi drivers, chauffeurs, bus and coach drivers show that public transport workers were at high risk at the beginning of the COVID-19 pandemic. Nevertheless, the public transport sector was required to continue services throughout the pandemic. OBJECTIVES This paper aims to develop a better understanding of the experiences of organizational leaders and workers within the UK public transport sector (bus, rail, and tram). Specifically, it aims to explore the perceived balance of risk and mitigation of SARS-CoV-2 transmission, report on their perceptions of safety in public transport during the pandemic and in the future, and consider how these perceptions and changes impact on long-term worker health and wellbeing. METHODS This study formed part of a larger stakeholder engagement with the public transport sector. Organizational leaders and workers were recruited (n = 18) and semi-structured interviews carried out between January and May 2021. Data were analysed thematically. RESULTS Overarching and subthemes were identified. Themes relating to perceptions and impacts of risk of COVID-19 for employees included: acceptability of risk for workers, perceptions of risk mitigation effectiveness, changes to working practices and their impact on morale and wellbeing, issues with compliance to mitigations such as social distancing and face coverings in passenger and co-worker groups alongside a lack of power to challenge behaviour effectively, and the roles of leadership and messaging. Themes related to long-lasting impacts of COVID-19 on working practices and effects on health and wellbeing included: continuing mitigations, impact of increasing passenger numbers, impact of vaccination programme, and impact of changes to business structure. CONCLUSIONS Most public transport employees reported feeling safe, related to the extent to which their role was public-facing. However, data were collected during a time of very low passenger numbers. Current mitigation measures were thought effective in reducing the risk of viral transmission, although measures may have a detrimental effect on worker morale and wellbeing. Issues relating to non-compliance with guidance and 'in-group' behaviour were identified. Impacts on wider business sustainability and individual wellbeing of staff should be considered when developing responses to any future pandemics. Recommendations are made for prioritizing employee engagement with colleagues, and the importance of strong leadership and clear messaging in promoting adherence to behavioural mitigations.
Collapse
Affiliation(s)
- Nicola Gartland
- Centre for Occupational and Environmental Health, School of Health Sciences, University of Manchester, Manchester, UK,Manchester Academic Health Science Centre, Manchester, UK,Author to whom correspondence should be addressed. e-mail:
| | - Anna Coleman
- Centre for Occupational and Environmental Health, School of Health Sciences, University of Manchester, Manchester, UK,Manchester Academic Health Science Centre, Manchester, UK
| | - David Fishwick
- Centre for Occupational and Environmental Health, School of Health Sciences, University of Manchester, Manchester, UK,Manchester Academic Health Science Centre, Manchester, UK,Centre for Workplace Health, Health and Safety Executive Science and Research Centre, Buxton, Derbyshire, UK
| | - Sheena Johnson
- People, Management and Organisations Division, Alliance Manchester Business School, University of Manchester, Manchester, UK
| | - Christopher J Armitage
- Manchester Academic Health Science Centre, Manchester, UK,Manchester Centre for Health Psychology, Division of Psychology & Mental Health, University of Manchester, Manchester, UK,NIHR Greater Manchester Patient Safety Translational Research Centre, Manchester, UK,Manchester University NHS Foundation Trust, Manchester, UK
| | - Martie van Tongeren
- Centre for Occupational and Environmental Health, School of Health Sciences, University of Manchester, Manchester, UK,Manchester Academic Health Science Centre, Manchester, UK
| |
Collapse
|
34
|
Albettar M, Leon Wang L, Katal A. A real-time web tool for monitoring and mitigating indoor airborne COVID-19 transmission risks at city scale. SUSTAINABLE CITIES AND SOCIETY 2022; 80:103810. [PMID: 35261876 PMCID: PMC8891144 DOI: 10.1016/j.scs.2022.103810] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 01/27/2022] [Accepted: 02/25/2022] [Indexed: 05/25/2023]
Abstract
Airborne transmission of aerosols contributes to a large portion of the SARS-CoV-2 spread indoors. This study develops a real-time interactive web-based platform for the public to compare various strategies to curb indoor airborne transmission of COVID-19 in different archetype buildings at a city scale. Although many countries have started vaccination and a gradual re-opening, because of emerging new variants of the virus and the possibility of future pandemics, a lively updated tool for monitoring and mitigation of infection risk is essential. As a demonstration, we evaluated the impacts of six mitigation measures on the infection risks in various building types in a city. It shows that the same strategy could perform quite differently, depending on building types and properties. All strategies are shown to reduce the infection risk but wearing a mask and reducing exposure time are the most effective strategies in many buildings, with around 60% reduction. Doubling the minimum required outdoor air ventilation rate is not as effective as other strategies to reduce the risk. It also causes considerable penalties on energy consumption. Therefore, new building ventilation standards, control actions, and design criteria should be considered to mitigate the infection risk and save energy.
Collapse
Affiliation(s)
- Maher Albettar
- Department of Building, Civil and Environmental Engineering, Concordia University, Montreal H3G 1M8, Canada
| | - Liangzhu Leon Wang
- Department of Building, Civil and Environmental Engineering, Concordia University, Montreal H3G 1M8, Canada
| | - Ali Katal
- Department of Building, Civil and Environmental Engineering, Concordia University, Montreal H3G 1M8, Canada
| |
Collapse
|
35
|
Guo Y, Zhang N, Hu T, Wang Z, Zhang Y. Optimization of energy efficiency and COVID-19 pandemic control in different indoor environments. ENERGY AND BUILDINGS 2022; 261:111954. [PMID: 35185270 PMCID: PMC8848536 DOI: 10.1016/j.enbuild.2022.111954] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 01/23/2022] [Accepted: 02/12/2022] [Indexed: 05/11/2023]
Abstract
The COVID-19 pandemic has led to considerable morbidity and mortality, and consumed enormous resources (e.g. energy) to control and prevent the disease. It is crucial to balance infection risk and energy consumption when reducing the spread of infection. In this study, a quantitative human, behavior-based, infection risk-energy consumption model for different indoor environments was developed. An optimal balance point for each indoor environment can be obtained using the anti-problem method. For this study we selected Wangjing Block, one of the most densely populated places in Beijing, as an example. Under the current ventilation standard (30 m3/h/person), prevention and control of the COVID-19 pandemic would be insufficient because the basic reproduction number (R0 ) for students, workers and elders are greater than 1. The optimal required fresh air ventilation rates in most indoor environments are near or below 60 m3/h/person, after considering the combined effects of multiple mitigation measures. In residences, sports buildings and restaurants, the demand for fresh air ventilation rate is relatively high. After our global optimization of infection risk control (R0 ≤ 1), energy consumption can be reduced by 13.7% and 45.1% on weekdays and weekends, respectively, in contrast to a strategy of strict control (R0 = 1 for each indoor environment).
Collapse
Affiliation(s)
- Yong Guo
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| | - Nan Zhang
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Tingrui Hu
- Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, China
| | - Zhenyu Wang
- College of Economics and Management, Beijing University of Technology, Beijing, China
| | - Yinping Zhang
- Department of Building Science, Tsinghua University, Beijing, China
- Beijing Key Laboratory of Indoor Air Quality Evaluation and Control, Beijing, China
| |
Collapse
|
36
|
Li X, Lester D, Rosengarten G, Aboltins C, Patel M, Cole I. A spatiotemporally resolved infection risk model for airborne transmission of COVID-19 variants in indoor spaces. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 812:152592. [PMID: 34954184 PMCID: PMC8695516 DOI: 10.1016/j.scitotenv.2021.152592] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 12/15/2021] [Accepted: 12/17/2021] [Indexed: 05/08/2023]
Abstract
The classic Wells-Riley model is widely used for estimation of the transmission risk of airborne pathogens in indoor spaces. However, the predictive capability of this zero-dimensional model is limited as it does not resolve the highly heterogeneous spatiotemporal distribution of airborne pathogens, and the infection risk is poorly quantified for many pathogens. In this study we address these shortcomings by developing a novel spatiotemporally resolved Wells-Riley model for prediction of the transmission risk of different COVID-19 variants in indoor environments. This modelling framework properly accounts for airborne infection risk by incorporating the latest clinical data regarding viral shedding by COVID-19 patients and SARS-CoV-2 infecting human cells. The spatiotemporal distribution of airborne pathogens is determined via computational fluid dynamics (CFD) simulations of airflow and aerosol transport, leading to an integrated model of infection risk associated with the exposure to SARS-CoV-2, which can produce quantitative 3D infection risk map for a specific SARS-CoV-2 variant in a given indoor space. Application of this model to airborne COVID-19 transmission within a hospital ward demonstrates the impact of different virus variants and respiratory PPE upon transmission risk. With the emergence of highly contagious SARS-CoV-2 variants such as the Delta and Omicron strains, respiratory PPE alone may not provide effective protection. These findings suggest a combination of optimal ventilation and respiratory PPE must be developed to effectively control the transmission of COVID-19 in healthcare settings and indoor spaces in general. This generalised risk estimation framework has the flexibility to incorporate further clinical data as such becomes available, and can be readily applied to consider a wide range of factors that impact transmission risk, including location and movement of infectious persons, virus variant and stage of infection, level of PPE and vaccination of infectious and susceptible individuals, impacts of coughing, sneezing, talking and breathing, and natural and mechanised ventilation and filtration.
Collapse
Affiliation(s)
- Xiangdong Li
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Daniel Lester
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia.
| | - Gary Rosengarten
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Craig Aboltins
- Department of Infectious Diseases, Northern Health, Epping, VIC 3076, Australia
| | - Milan Patel
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Ivan Cole
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| |
Collapse
|
37
|
Fan M, Fu Z, Wang J, Wang Z, Suo H, Kong X, Li H. A review of different ventilation modes on thermal comfort, air quality and virus spread control. BUILDING AND ENVIRONMENT 2022; 212:108831. [PMID: 35125624 PMCID: PMC8799382 DOI: 10.1016/j.buildenv.2022.108831] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/11/2022] [Accepted: 01/21/2022] [Indexed: 05/12/2023]
Abstract
In the era of Corona Virus Disease 2019 (COVID-19), inappropriate indoor ventilation may turn out to be the culprit of microbial contamination in enclosed spaces and deteriorate the environment. To collaboratively improve the thermal comfort, air quality and virus spread control effect, it was essential to have an overall understanding of different ventilation modes. Hence, this study reviewed the latest scientific literature on indoor ventilation modes and manuals of various countries, identified characteristics of different ventilation modes and evaluated effects in different application occasions, wherefore to further propose their main limitations and solutions in the epidemic era. For thermal comfort, various non-uniform ventilation modes could decrease the floor-to-ceiling temperature difference, draft rate or PPD by 60%, 80% or 33% respectively, or increase the PMV by 45%. Unsteady ventilation modes (including intermittent ventilation and pulsating ventilation) could lower PPD values by 12%-37.8%. While for air quality and virus spread control, non-uniform ventilation modes could lower the mean age of air or contaminants concentration by 28.3%-47% or 15%-47% respectively, increase the air change efficiency, contaminant removal effectiveness or protection efficiency by 6.6%-10.4%, 22.6% or 14%-50% respectively. Unsteady ventilation mode (pulsating ventilation) could reduce the peak pollutant concentration and exposure time to undesirable concentrations by 31% and 48% respectively. Non-uniform modes and unsteady modes presented better performance in thermal comfort, air quality and virus spread control, whereas relevant performance evaluation indexes were still imperfect and the application scenarios were also limited.
Collapse
Affiliation(s)
- Man Fan
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Zheng Fu
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Jia Wang
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Zhaoying Wang
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Hanxiao Suo
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Xiangfei Kong
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| | - Han Li
- School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401, China
| |
Collapse
|
38
|
Coyle JP, Derk RC, Lindsley WG, Boots T, Blachere FM, Reynolds JS, McKinney WG, Sinsel EW, Lemons AR, Beezhold DH, Noti JD. Reduction of exposure to simulated respiratory aerosols using ventilation, physical distancing, and universal masking. INDOOR AIR 2022; 32:e12987. [PMID: 35225389 PMCID: PMC8988470 DOI: 10.1111/ina.12987] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 12/23/2021] [Accepted: 12/24/2021] [Indexed: 06/14/2023]
Abstract
To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3-3 µm coughed and exhaled aerosol particles by >77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, that is, coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a layered mitigation strategy approach of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment.
Collapse
Affiliation(s)
- Jayme P. Coyle
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Raymond C. Derk
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - William G. Lindsley
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Theresa Boots
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Francoise M. Blachere
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Jeffrey S. Reynolds
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Walter G. McKinney
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Erik W. Sinsel
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Angela R. Lemons
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - Donald H. Beezhold
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| | - John D. Noti
- Health Effects Laboratory DivisionCenters for Disease Control and PreventionNational Institute for Occupational Safety and HealthMorgantownWest VirginiaUSA
| |
Collapse
|
39
|
Esposito M, Salerno M, Di Nunno N, Ministeri F, Liberto A, Sessa F. The Risk of COVID-19 Infection in Prisons and Prevention Strategies: A Systematic Review and a New Strategic Protocol of Prevention. Healthcare (Basel) 2022; 10:270. [PMID: 35206884 PMCID: PMC8872582 DOI: 10.3390/healthcare10020270] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 01/25/2022] [Accepted: 01/28/2022] [Indexed: 12/14/2022] Open
Abstract
Health risks within prisons are well known and have worsened with the 2019 coronavirus pandemic (COVID-19), becoming a public health emergency. To date, there are more than 10 million inmates in the world; in most cases, conditions are bad and health care is scarce. A SARS-CoV-2 outbreak inside a prison is extremely rapid. The aim of this systematic review was to analyze all possible prevention techniques to reduce the risk of COVID-19 related infection within prisons. A systematic review of the literature was performed according to the PRISMA guidelines. Scopus, Web of Science, PubMed, and Google Scholar were used as search engines from 1 January 2020 to 1 November 2021 to evaluate the prevention of COVID-19 in prisoners. A total of 1757 articles were collected. Of them, 486 duplicates were removed. A total of 1250 articles did not meet the inclusion criteria. In conclusion, 21 articles were included in the present systematic review. From this analysis, it emerged that the most common COVID-19 prevention methods were the screening of the entire population (prisoners and workers) inside the prison through swab analysis and the reduction in overcrowding in prisons. Few studies concerned the prevention of COVID-19 infection through vaccination and the implementation of quarantine. To our knowledge, this is the first systematic review that evaluates the prevention of COVID-19 within jails and the real effectiveness of all possible methods used and published in the literature. Finally, a very useful strategic protocol is provided to reduce the incidence of infection and to control and manage COVID-19 in prisons.
Collapse
Affiliation(s)
- Massimiliano Esposito
- Department of Medical, Surgical and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95121 Catania, Italy; (M.E.); (M.S.); (F.M.); (A.L.)
| | - Monica Salerno
- Department of Medical, Surgical and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95121 Catania, Italy; (M.E.); (M.S.); (F.M.); (A.L.)
| | - Nunzio Di Nunno
- Department of History, Society and Studies on Humanity, University of Salento, 73100 Lecce, Italy;
| | - Federica Ministeri
- Department of Medical, Surgical and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95121 Catania, Italy; (M.E.); (M.S.); (F.M.); (A.L.)
| | - Aldo Liberto
- Department of Medical, Surgical and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95121 Catania, Italy; (M.E.); (M.S.); (F.M.); (A.L.)
| | - Francesco Sessa
- Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
| |
Collapse
|
40
|
Abstract
The COVID-19 pandemic forced the accessibility, social gathering, lifestyle, and working environment to be changed to reduce the infection. Coronavirus spreads between people in several different ways. Small liquid particles (aerosols, respiratory droplets) from an infected person are transmitted through air and surfaces that are in contact with humans. Reducing transmission through modified heating, ventilation, and air conditioning (HVAC) systems and building design are potential solutions. A comprehensive review of the engineering control preventive measures to mitigate COVID-19 spread, healthy building design, and material was carried out. The current state-of-the-art engineering control preventive measures presented include ultraviolet germicidal irradiation (UVGI), bipolar ionization, vertical gardening, and indoor plants. They have potential to improve the indoor air quality. In addition, this article presents building design with materials (e.g., copper alloys, anti-microbial paintings) and smart technologies (e.g., automation, voice control, and artificial intelligence-based facial recognition) to mitigate the infections of communicable diseases.
Collapse
|
41
|
Risbeck MJ, Bazant MZ, Jiang Z, Lee YM, Drees KH, Douglas JD. Modeling and multiobjective optimization of indoor airborne disease transmission risk and associated energy consumption for building HVAC systems. ENERGY AND BUILDINGS 2021; 253:111497. [PMID: 34580563 PMCID: PMC8457902 DOI: 10.1016/j.enbuild.2021.111497] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 09/17/2021] [Accepted: 09/20/2021] [Indexed: 05/22/2023]
Abstract
The COVID-19 pandemic has renewed interest in assessing how the operation of HVAC systems influences the risk of airborne disease transmission in buildings. Various processes, such as ventilation and filtration, have been shown to reduce the probability of disease spread by removing or deactivating exhaled aerosols that potentially contain infectious material. However, such qualitative recommendations fail to specify how much of these or other disinfection techniques are needed to achieve acceptable risk levels in a particular space. An additional complication is that application of these techniques inevitably increases energy costs, the magnitude of which can vary significantly based on local weather. Moreover, the operational flexibility available to the HVAC system may be inherently limited by equipment capacities and occupant comfort requirements. Given this knowledge gap, we propose a set of dynamical models that can be used to estimate airborne transmission risk and energy consumption for building HVAC systems based on controller setpoints and a forecast of weather conditions. By combining physics-based material balances with phenomenological models of the HVAC control system, it is possible to predict time-varying airflows and other HVAC variables, which are then used to calculate key metrics. Through a variety of examples involving real and simulated commercial buildings, we show that our models can be used for monitoring purposes by applying them directly to transient building data as operated, or they may be embedded within a multi-objective optimization framework to evaluate the tradeoff between infection risk and energy consumption. By combining these applications, building managers can determine which spaces are in need of infection risk reduction and how to provide that reduction at the lowest energy cost. The key finding is that both the baseline infection risk and the most energy-efficient disinfection strategy can vary significantly from space to space and depend sensitively on the weather, thus underscoring the importance of the quantitative predictions provided by the models.
Collapse
Affiliation(s)
| | - Martin Z Bazant
- Departments of Chemical Engineering and Mathematics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | | | - Young M Lee
- Johnson Controls International plc, Milwaukee, WI, USA
| | - Kirk H Drees
- Johnson Controls International plc, Milwaukee, WI, USA
| | | |
Collapse
|
42
|
Kurnitski J, Kiil M, Wargocki P, Boerstra A, Seppänen O, Olesen B, Morawska L. Respiratory infection risk-based ventilation design method. BUILDING AND ENVIRONMENT 2021; 206:108387. [PMID: 34602721 PMCID: PMC8462055 DOI: 10.1016/j.buildenv.2021.108387] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/05/2021] [Accepted: 09/22/2021] [Indexed: 05/24/2023]
Abstract
A new design method is proposed to calculate outdoor air ventilation rates to control respiratory infection risk in indoor spaces. We propose to use this method in future ventilation standards to complement existing ventilation criteria based on the perceived air quality and pollutant removal. The proposed method makes it possible to calculate the required ventilation rate at a given probability of infection and quanta emission rate. Present work used quanta emission rates for SARS-CoV-2 and consequently the method can be applied for other respiratory viruses with available quanta data. The method was applied to case studies representing typical rooms in public buildings. To reduce the probability of infection, the total airflow rate per infectious person revealed to be the most important parameter to reduce the infection risk. Category I ventilation rate prescribed in the EN 16798-1 standard satisfied many but not all type of spaces examined. The required ventilation rates started from about 80 L/s per room. Large variations between the results for the selected case studies made it impossible to provide a simple rule for estimating the required ventilation rates. Consequently, we conclude that to design rooms with a low infection risk the newly developed ventilation design method must be used.
Collapse
Affiliation(s)
- Jarek Kurnitski
- Department of Civil Engineering and Architecture, Tallinn University of Technology, Tallinn, Estonia
- Department of Civil Engineering, Aalto University, Espoo, Finland
| | - Martin Kiil
- Department of Civil Engineering and Architecture, Tallinn University of Technology, Tallinn, Estonia
| | - Pawel Wargocki
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark
| | - Atze Boerstra
- BBA Binnenmilieu, the Netherlands
- Faculty of Architecture and the Built Environment, Delft University of Technology, the Netherlands
| | - Olli Seppänen
- Nordic Ventilation Group, SCANVAC, Scandinavian Federation of Heating, Ventilation and Sanitary Engineering Associations in Denmark, Finland, Iceland, Norway and, Sweden
| | - Bjarne Olesen
- International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark
| | - Lidia Morawska
- International Laboratory for Air Quality and Heath, Queensland University of Technology, Brisbane, Australia
- Global Centre for Clean Air Research (GCARE), Department of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, UK
| |
Collapse
|
43
|
Xu Y, Cai J, Li S, He Q, Zhu S. Airborne infection risks of SARS-CoV-2 in U.S. schools and impacts of different intervention strategies. SUSTAINABLE CITIES AND SOCIETY 2021; 74:103188. [PMID: 34306993 PMCID: PMC8290078 DOI: 10.1016/j.scs.2021.103188] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 06/30/2021] [Accepted: 07/15/2021] [Indexed: 05/05/2023]
Abstract
The potential airborne transmission of SARS-CoV-2 has triggered concerns as schools continue to reopen and resume in-person instruction during the current COVID-19 pandemic. It is critical to understand the risks of airborne SARS-CoV-2 transmission under different epidemiological scenarios and operation strategies for schools to make informed decisions to mitigate infection risk. Through scenario-based analysis, this study estimates the airborne infection risk of SARS-CoV-2 in 111,485 U.S. public and private schools and evaluates the impacts of different intervention strategies, including increased ventilation, air filtration, and hybrid learning. Schools in more than 90% of counties exhibit infection risk of higher than 1%, indicating the significance of implementing intervention strategies. Among the considered strategies, air filtration is found to be most effective: the school average infection risk when applying MERV 13 is over 30% less than the risk levels correlating with the use of increased ventilation and hybrid learning strategies, respectively. For most schools, it is necessary to adopt combined intervention strategies to ensure the infection risk below 1%. The results provide insights into airborne infection risk in schools under various scenarios and may guide schools and policymakers in developing effective operations strategies to maintain environmental health.
Collapse
Affiliation(s)
- Yifang Xu
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville. 851 Neyland Drive, Knoxville TN 37996, USA
| | - Jiannan Cai
- Department of Construction Science, The University of Texas at San Antonio. 501 W César E Chávez Blvd, San Antonio, TX 78207, USA
| | - Shuai Li
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville. 851 Neyland Drive, Knoxville TN 37996, USA
| | - Qiang He
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville. 851 Neyland Drive, Knoxville TN 37996, USA
| | - Siyao Zhu
- Department of Civil and Systems Engineering, Johns Hopkins University, Baltimore. 3400 N. Charles St., Baltimore, MD 21218, USA
| |
Collapse
|