1
|
Mudhaffer S, Althagafi R, Haider J, Satterthwaite J, Silikas N. Effects of printing orientation and artificial ageing on martens hardness and indentation modulus of 3D printed restorative resin materials. Dent Mater 2024; 40:1003-1014. [PMID: 38735775 DOI: 10.1016/j.dental.2024.05.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/29/2024] [Accepted: 05/03/2024] [Indexed: 05/14/2024]
Abstract
BACKGROUND Three-dimensional (3D) printing is increasingly used to fabricate dental restorations due to its enhanced precision, consistency and time and cost-saving advantages. The properties of 3D-printed resin materials can be influenced by the chosen printing orientation which can impact the mechanical characteristics of the final products. PURPOSE The objective of this study was to evaluate the influence of printing orientation and artificial ageing on the Martens hardness (HM) and indentation modulus (EIT) of 3D-printed definitive and temporary dental restorative resins. METHODS Disk specimens (20 mm diameter × 2 mm height) were additively manufactured in three printing orientations (0°, 45°, 90°) using five 3D-printable resins: VarseoSmile Crownplus (VCP), Crowntec (CT), Nextdent C&B MFH (ND), Dima C&B temp (DT), and GC temp print (GC). The specimens were printed using a DLP 3D-printer (ASIGA MAX UV), while LavaTM Ultimate (LU) and Telio CAD (TC) served as milled control materials. Martens hardness (HM) and indentation modulus (EIT) were tested both before and after storage in distilled water and artificial saliva for 1, 30, and 90 days at 37 °C. RESULTS 90° printed specimens exhibited higher HM than the other orientations at certain time points, but no significant differences were observed in HM and EIT between orientations for all 3D-printed materials after 90 days of ageing in both aging media. LU milled control material exhibited the highest HM and EIT among the tested materials, while TC, the other milled control, showed similar values to the 3D printed resins. CT and VCP (definitive resins) and ND displayed higher Martens parameters compared to DT and GC (temporary resins). The hardness of the 3D-printed materials was significantly impacted by artificial ageing compared to the controls, with ND having the least hardness reduction percentage amongst all 3D-printed materials. The hardness reduction percentage in distilled water and artificial saliva was similar for all materials except for TC, where higher reduction was noted in artificial saliva. SIGNIFICANCE The used 3D printed resins cannot yet be considered viable alternatives to milled materials intended for definitive restorations but are preferable for use as temporary restorations.
Collapse
Affiliation(s)
- Shaymaa Mudhaffer
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia.
| | - Rana Althagafi
- Substitutive Dental Sciences, Faculty of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, UK
| | - Julian Satterthwaite
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK.
| |
Collapse
|
2
|
Deshmukh K, Bit A. Numerical analysis of scaffold degradation in cryogenic environment: impact of cell migration and cell apoptosis. Biomed Phys Eng Express 2024; 10:035010. [PMID: 38447212 DOI: 10.1088/2057-1976/ad30cc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 03/06/2024] [Indexed: 03/08/2024]
Abstract
The analysis of degradation in the presence of cell death and migration is a critical aspect of research in various biological fields, such as tissue engineering, regenerative medicine, and disease pathology. In present study, numerical study of degradation of scaffold were performed in present of cells, cell apoptosis and cell migration. A poly electrolyte complex (PEC) silk fibroin scaffold was used for degradation study. Degradation study in the presence of cells and migration were performed at fixed pH concentration 7.2. Similarly, degradation study of scaffold were performed at different pH cell apoptosis. A transient analysis of scaffold was evaluated in COMSOL 5.5 in presence of cryogenic temperature at different temperature gradient. The parameters; temperature, stress, strain tensor and deformation gradient associated with the degradation of polyelectrolyte complex scaffold were evaluated. Result shows that in both geometries minimum temperature had been achieved as 230.051 K at point P4 in series view and parallel view and at a point P3 for cell migration study for -5 k min-1and -1 k min-1, respectively. The maximum stress had been generated for 5.57 × 107N m-2for the temperature gradient of -2 K min-1at T cycle in the case of cell migration study. In contrast in series view the maximum stress 2.9 × 107 N m-2were observed at P4 which was higher as compare to P3. Similarly, for a parallel view, maximum stress (3.93 × 107 N m-2) was obtained for point P3. It had been observed that the maximum strain tensor 5.21 × 10-3, 5.15 × 10-3and 5.26 × 10-3was generated in series view at 230 k on a point P3 for - 1, -2 and -5 K min-1, respectively. Similarly, the maximum strain tensor 8.16 × 10-3, 8.09 × 10-3and 8.09 × 10-3was generated in parallel view at 230 k on a point P3 for -1, -2 and -5 K min-1, respectively. In the presence of cells, at a point P4 for temperature gradient of -1 and -2 K min-1, it had been closed to the scaffold wall, which had a different temperature profile than the point P3 and scaffold comes to the contact with the cells. The analysis of PEC scaffold degradation in the presence of cells, including cell apoptosis and migration, offers significant insights into the relationship between scaffold properties, cell behaviour, and tissue regeneration.
Collapse
Affiliation(s)
- Khemraj Deshmukh
- Department of Biomedical Engineering, Parul Institute of Technology (Parul University), Vadodra, Gujraat , India
| | - Arindam Bit
- Department of Biomedical Engineering, National Institute of Technology, Raipur, India
| |
Collapse
|
3
|
PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers (Basel) 2023; 15:polym15020386. [PMID: 36679266 PMCID: PMC9864167 DOI: 10.3390/polym15020386] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/06/2023] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared to traditional metal and ceramic dental materials, PEEK dental implants exhibit less stress shielding, thus better matching the mechanical properties of bone. As a promising medical material, PEEK can be used as implant abutments, removable and fixed prostheses, and maxillofacial prostheses. It can be blended with materials such as fibers and ceramics to improve its mechanical strength for better clinical dental applications. Compared to conventional pressed and CAD/CAM milling fabrication, 3D-printed PEEK exhibits excellent flexural and tensile strength and parameters such as printing temperature and speed can affect its mechanical properties. However, the bioinert nature of PEEK can make adhesive bonding difficult. The bond strength can be improved by roughening or introducing functional groups on the PEEK surface by sandblasting, acid etching, plasma treatment, laser treatment, and adhesive systems. This paper provides a comprehensive overview of the research progress on the mechanical properties of PEEK for dental applications in the context of specific applications, composites, and their preparation processes. In addition, the research on the adhesive properties of PEEK over the past few years is highlighted. Thus, this review aims to build a conceptual and practical toolkit for the study of the mechanical and adhesive properties of PEEK materials. More importantly, it provides a rationale and a general new basis for the application of PEEK in the dental field.
Collapse
|
4
|
Pidhatika B, Widyaya VT, Nalam PC, Swasono YA, Ardhani R. Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry. Polymers (Basel) 2022; 14:polym14245526. [PMID: 36559893 PMCID: PMC9787615 DOI: 10.3390/polym14245526] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 12/23/2022] Open
Abstract
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium-the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Collapse
Affiliation(s)
- Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
- Collaborative Research Center for Biomedical Scaffolds, National Research and Innovation Agency of the Republic Indonesia and Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
| | - Vania Tanda Widyaya
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Prathima C. Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY 14260-1900, USA
| | - Yogi Angga Swasono
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
- Correspondence:
| |
Collapse
|
5
|
Baran MC, Demirci F, Tuzlalı M. Comparison of marginal and internal adaptation of three-unit fixed dental prostheses made using CAD/CAM metal-free materials. Eur J Oral Sci 2022; 130:e12901. [PMID: 36428097 DOI: 10.1111/eos.12901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 10/17/2022] [Indexed: 11/27/2022]
Abstract
The aim of this study was to compare the marginal and internal adaptation of three-unit fixed dental prostheses (FDPs) fabricated from different metal-free materials using CAD/CAM methods. A total of 100 three-unit FDPs were produced from a cubic zirconia, a fiber-reinforced resin composite, a polyetheretherketone (PEEK), a polyetherketoneketone (PEKK), and a polymer composite material by the CAD/CAM method (n = 20 per material). The zirconia group was considered the control/reference material. Marginal and internal gap values of the produced FDPs were measured using the silicone replica method at ×40 magnification under a stereomicroscope. The obtained data were analyzed using one-way ANOVA and Tukey's HSD tests. The marginal and internal gap values for the cubic zirconia material were found to be statistically significantly lower than those seen for the PEEK, polymer composite, PEKK, and fiber-reinforced resin composite materials. While the marginal and internal adaptation of the cubic zirconia material was found to be better than the others, it should be noted that the marginal and internal gap values for all other materials tested were found to be within the clinically acceptable range.
Collapse
Affiliation(s)
- Melike Cigdem Baran
- Department of Prosthodontics, Faculty of Dentistry, Inonu University, Malatya, Turkey
| | - Fatih Demirci
- Department of Prosthodontics, Faculty of Dentistry, Inonu University, Malatya, Turkey
| | - Mesut Tuzlalı
- Department of Prosthodontics, Faculty of Dentistry, Inonu University, Malatya, Turkey
| |
Collapse
|
6
|
Analysis of the Deflection, Bristle Splaying, and Abrasion of a Single Tuft of a Polybutylene Terephthalate Toothbrush after Use: A Randomized Controlled Trial. MATERIALS 2022; 15:ma15144890. [PMID: 35888356 PMCID: PMC9320165 DOI: 10.3390/ma15144890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/11/2022] [Accepted: 07/12/2022] [Indexed: 12/07/2022]
Abstract
The aim of this study is to clarify the deflection, splaying, and abrasion of single tufts of polybutylene terephthalate (PBT) toothbrushes after use. A single-center randomized controlled trial is performed. The changes in deflection, bristle splaying, and abrasion are investigated for the middle single tuft of the top line (top–middle tuft) and the middle single tuft of the bottom line (bottom–middle tuft) of PBT toothbrushes with medium stiffness after 1 month, 2 months, and 3 months of use by 34 participants. A soft-material bending-resistance tester is used to assess the deflection of the single tufts. The deflection value of the top–middle tuft significantly increased after 1 month of use compared with the baseline. In contrast, the deflection of the bottom–middle tuft significantly increased after 3 months of use compared with the baseline and after 1 month and 2 months of use. Importantly, the change in deflection was distinctly different between the top– and bottom–middle tufts. The bristle splaying of both tufts significantly increased after use, but a significant change in bristle abrasion was not found. The bending stiffness of the top tuft of a PBT toothbrush may decrease more rapidly than that of the bottom tuft with use.
Collapse
|