1
|
McConnochie G, Fox A, Badger H, Bellenger C, Thewlis D. Fatigue assessment in distance runners: A scoping review of inertial sensor-based biomechanical outcomes and their relation to fatigue markers and assessment conditions. Gait Posture 2024; 115:21-33. [PMID: 39471649 DOI: 10.1016/j.gaitpost.2024.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 09/23/2024] [Accepted: 10/13/2024] [Indexed: 11/01/2024]
Abstract
BACKGROUND Fatigue manifests as a decline in performance during high-intensity and prolonged exercise. With technological advancements and the increasing adoption of inertial measurement units (IMUs) in sports biomechanics, there is an opportunity to enhance our understanding of running-related fatigue beyond controlled laboratory environments. RESEARCH QUESTION How have IMUs have been used to assess running biomechanics under fatiguing conditions? METHODS Following the PRISMA-ScR guidelines, our literature search covered six databases without date restrictions until September 2024. The Population, Concept, and Context criteria were used: Population (distance runners ranging from novice to competitive), Concept (fatigue induced by running a distance over 400 m), Context (assessment of fatigue using accelerometer, gyroscope, and/or magnetometer wearable devices). Biomechanical outcomes were extracted and synthesised, and interpreted in the context of three main study characteristics (cohort ability, testing environment, and the inclusion of physiological outcomes) to explore their potential role in influencing outcomes. RESULTS A total of 88 articles were included in the review. There was a high prevalence of treadmill-based studies (n=46, 52%), utilising only 1-2 sensors (n=69, 78%), and cohorts ranged in experience, from sedentary to elite-level runners, and were largely comprised of males (69% of all participants). The majority of biomechanical outcomes assessed showed varying responses to fatigue across studies, likely attributable to individual variability, exercise intensity, and differences in fatigue protocol settings and prescriptions. Spatiotemporal outcomes such as stride time and frequency (n=37, 42 %) and impact accelerations (n=55, 62%) were more widely assessed, with a fatigue response that appeared population and environment specific. SIGNIFICANCE There was notable heterogeneity in the IMU-based biomechanical outcomes and methods evaluated in this review. The review findings emphasise the need for standardisation of IMU-based outcomes and fatigue protocols to promote interpretable metrics and facilitate inter-study comparisons.
Collapse
Affiliation(s)
- Grace McConnochie
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia.
| | - Aaron Fox
- Institute for Physical Activity and Nutrition, School of Exercise and Nutrition Sciences, Deakin University, Australia
| | - Heather Badger
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia
| | - Clint Bellenger
- Alliance for Research in Exercise, Nutrition and Activity (ARENA); Allied Health and Human Performance Unit; University of South Australia, Australia
| | - Dominic Thewlis
- Centre for Orthopaedic & Trauma Research, Adelaide Medical School, University of Adelaide, Australia
| |
Collapse
|
2
|
Fain A, Nindl BC, McCarthy A, Fuller JT, Wills JA, Doyle TLA. Load increases IMU signal attenuation per step but reduces IMU signal attenuation per kilometre. Gait Posture 2024; 113:519-527. [PMID: 39173442 DOI: 10.1016/j.gaitpost.2024.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 06/27/2024] [Accepted: 08/06/2024] [Indexed: 08/24/2024]
Abstract
BACKGROUND Despite deleterious biomechanics associated with injury, particularly as it pertains to load carriage, there is limited research on the association between physical demands and variables captured with wearable sensors. While inertial measurement units (IMUs) can be used as surrogate measures of ground reaction force (GRF) variables, it is unclear if these data are sensitive to military-specific task demands. RESEARCH QUESTION Can wearable sensors characterise physical load and demands placed on individuals in different load, speed and grade conditions? METHODS Data were collected on 20 individuals who were self-reportedly free from current injury, recreationally active, and capable of donning 23 kg in the form of a weighted vest. Each participant walked and ran on flat, uphill (+6 %) and downhill (-6 %) without and with load (23 kg). Data were collected synchronously from optical motion capture (OMC) and IMUs placed on the distal limb and the pelvis. Data from an 8-second window was used to generate a participant-based mean of OMC and IMU variables of interest. Repeated Measures ANOVA was used to measure main and interaction effects of load, speed, and grade. Simple linear regression was used to elucidate a relationship between OMC measures and estimated metabolic cost (EMC) to IMU measures. RESULTS Load reduces foot and pelvic accelerations (p<0.001) but elevate signal attenuation per step (p=0.044). Conversely, attenuation per kilometre is lowered with the addition of load (p=0.017). Uphill had the lowest attenuation per step (p=0.003) and kilometre (p≤0.033) in walking, while downhill had the greatest attenuation per step (p≤0.002) and per kilometre (p≤0.004). Attenuation measures are inconsistently moderately related to limb negative work (R≤0.57). EMC is moderately positively related to unloaded running (R≥0.39), and moderately negatively related to walking with and without load (R≤-0.52). SIGNIFICANCE While load reduces peak accelerations at both the pelvis and foot. However, it may increase demand on the lower extremity to attenuate the signal between the two sensors with each step, while attenuation over time reduces with load.
Collapse
Affiliation(s)
- AuraLea Fain
- Biomechanics, Physical Performance, and Exercise (BioPPEx) Research Group, Macquarie University, Sydney, Australia; Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Bradley C Nindl
- Neuromuscular Research Lab/Warrior Performance Center, University of Pittsburgh, Pittsburgh, PA, USA; Department of Sports Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Ayden McCarthy
- Biomechanics, Physical Performance, and Exercise (BioPPEx) Research Group, Macquarie University, Sydney, Australia; Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Joel T Fuller
- Biomechanics, Physical Performance, and Exercise (BioPPEx) Research Group, Macquarie University, Sydney, Australia; Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Jodie A Wills
- Biomechanics, Physical Performance, and Exercise (BioPPEx) Research Group, Macquarie University, Sydney, Australia; Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Tim L A Doyle
- Biomechanics, Physical Performance, and Exercise (BioPPEx) Research Group, Macquarie University, Sydney, Australia; Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia.
| |
Collapse
|
3
|
Desai GA, DeJong Lempke AF, Harezlak J, Gruber AH. Sex differences in body composition and shock attenuation during running. J Biomech 2024; 173:112245. [PMID: 39084062 DOI: 10.1016/j.jbiomech.2024.112245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 07/03/2024] [Accepted: 07/22/2024] [Indexed: 08/02/2024]
Abstract
Running-related impact shock is absorbed via biological tissue deformation. Given known sex differences in body composition, shock attenuation may also differ between sexes thereby influencing sex-specific running-related injury risk. This study examined sex differences in body composition and shock attenuation during running. Seventeen female (mean ± 1SD age: 34.7 ± 16.1) and twenty-one male runners (age: 29.0 ± 13.8) ran overground as inertial measurement units with triaxial accelerometers measured impact shock at the distal tibia and low-back. Frequency-domain axial and resultant shock attenuation were calculated between the low-back relative to the tibia using a transfer function of the power spectral density within 9-20, 21-35, and 36-50 Hz. Bone mineral density and content, fat and lean mass were measured in the lower extremity and pelvis/gynoid regions using dual x-ray absorptiometry. The association between sex and shock attenuation was tested using age-adjusted linear regression models, adjusted and unadjusted for body composition as a post-hoc analysis (α = 0.05). Body composition variables normalized to body mass were compared between sexes using independent samples t-tests (α = 0.05). Body composition differed between sexes (p-range: <0.001-0.01, Cohen's d range: 0.17-2.41). Before adjusting for body composition, sex was not significantly associated with axial or resultant shock attenuation (p > 0.05), but adjusting for select body composition variables like lower extremity lean and bone mass revealed greater attenuation in females than males (β-range: -124.76 to -46.42, negative indicates greater attenuation; p-range = 0.004-0.04). Sex may not influence shock attenuation during running, but body composition must be accounted for to better understand this association and consequently sex-specific tissue capacities relative to applied loads.
Collapse
Affiliation(s)
- Gauri A Desai
- Department of Kinesiology, School of Public Health, University of Maryland, College Park, MD, USA.
| | - Alexandra F DeJong Lempke
- Department of Physical Medicine and Rehabilitation, Virginia Commonwealth University, Richmond, VA, USA.
| | - Jaroslaw Harezlak
- Department of Epidemiology and Biostatistics, School of Public Health, Indiana University-Bloomington, Bloomington, IN, USA.
| | - Allison H Gruber
- Department of Kinesiology, School of Public Health, Indiana University-Bloomington, Bloomington, IN, USA.
| |
Collapse
|
4
|
Jimenez-Perez I, Priego-Quesada JI, Camacho-García A, Cibrián Ortiz de Anda RM, Pérez-Soriano P. Impact accelerations during a prolonged run using a microwavable self-customised foot orthosis. Sports Biomech 2024; 23:935-948. [PMID: 34126852 DOI: 10.1080/14763141.2021.1902553] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Accepted: 03/08/2021] [Indexed: 10/21/2022]
Abstract
The use of custom-made foot orthoses has been associated with numerous benefits, such as decreased impact accelerations. However, it is not known whether this effect could be due to better customisation. The present study analysed the effects of the first generation of a microwavable prefabricated self-customised foot orthosis vs. a prefabricated standard one on impact accelerations throughout a prolonged run. Thirty runners performed two tests of 30-min running on a treadmill, each one with an orthosis condition. Impact acceleration variables of tibia and head were recorded every 5 min. Microwavable self-customised foot orthosis increased the following variables in the first instants compared to the prefabricated standard one: tibial peak (min1: 6.5 (1.8) vs. 6.0 (1.7) g, P = .009, min5: 6.6 (1.7) vs. 6.2 (1.7) g, P = .035), tibial magnitude (min1: 8.3 (2.6) vs. 7.7 (2.4) g, P = .030, min5: 8.5 (2.6) vs. 7.9 (2.5) g, P = .026) and shock attenuation (min1: 61.4 (16.8) vs. 56.3 (16.3)%, P = .014, min5: 62.0 (15.5) vs. 57.2 (15.3)%, P = .040), and tibial rate throughout the entire run (504.3 (229.7) vs. 422.7 (212.9) g/s, P = .006). However, it was more stable throughout 30-min running (P < .05). These results show that the shape customisation entailed by the thermoformable material does not provide impact acceleration improvements.
Collapse
Affiliation(s)
- Irene Jimenez-Perez
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, Universitat de València, Valencia, Spain
- Research Group in Medical Physics (GIFIME), Department of Physiology, Universitat de València, Valencia, Spain
| | - Jose Ignacio Priego-Quesada
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, Universitat de València, Valencia, Spain
- Research Group in Medical Physics (GIFIME), Department of Physiology, Universitat de València, Valencia, Spain
| | - Andrés Camacho-García
- Department of Communications, Universitat Politècnica de València, Alcoy, Alicante, Spain
| | | | - Pedro Pérez-Soriano
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, Universitat de València, Valencia, Spain
| |
Collapse
|
5
|
Pareja-Cano Á, Arjona JM, Caulfield B, Cuesta-Vargas A. Parameterization of Biomechanical Variables through Inertial Measurement Units (IMUs) in Occasional Healthy Runners. SENSORS (BASEL, SWITZERLAND) 2024; 24:2191. [PMID: 38610402 PMCID: PMC11014260 DOI: 10.3390/s24072191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 03/20/2024] [Accepted: 03/27/2024] [Indexed: 04/14/2024]
Abstract
Running is one of the most popular sports practiced today and biomechanical variables are fundamental to understanding it. The main objectives of this study are to describe kinetic, kinematic, and spatiotemporal variables measured using four inertial measurement units (IMUs) in runners during treadmill running, investigate the relationships between these variables, and describe differences associated with different data sampling and averaging strategies. A total of 22 healthy recreational runners (M age = 28 ± 5.57 yrs) participated in treadmill measurements, running at their preferred speed (M = 10.1 ± 1.9 km/h) with a set-up of four IMUs placed on tibias and the lumbar area. Raw data was processed and analysed over selections spanning 30 s, 30 steps and 1 step. Very strong positive associations were obtained between the same family variables in all selections. The temporal variables were inversely associated with the step rate variable in the selection of 30 s and 30 steps of data. There were moderate associations between kinetic (forces) and kinematic (displacement) variables. There were no significant differences between the biomechanics variables in any selection. Our results suggest that a 4-IMU set-up, as presented in this study, is a viable approach for parameterization of the biomechanical variables in running, and also that there are no significant differences in the biomechanical variables studied independently, if we select data from 30 s, 30 steps or 1 step for processing and analysis. These results can assist in the methodological aspects of protocol design in future running research.
Collapse
Affiliation(s)
- Álvaro Pareja-Cano
- Grupo Clinimetría en Fisioterapia (CTS 631), Department of Physiotherapy, Faculty of Health Sciences, University of Málaga, 29071 Málaga, Spain; (Á.P.-C.); (J.M.A.)
- Instituto de Investigación Biomédica de Málaga y Plataforma en Nanomedicina (IBIMA Plataforma Bionand) Grupo Clinimetria (F-14), 29590 Málaga, Spain
| | - José María Arjona
- Grupo Clinimetría en Fisioterapia (CTS 631), Department of Physiotherapy, Faculty of Health Sciences, University of Málaga, 29071 Málaga, Spain; (Á.P.-C.); (J.M.A.)
- Instituto de Investigación Biomédica de Málaga y Plataforma en Nanomedicina (IBIMA Plataforma Bionand) Grupo Clinimetria (F-14), 29590 Málaga, Spain
- Faculty of Sciences and Technology, University Isabel I, 09003 Burgos, Spain
| | - Brian Caulfield
- School of Public Health, Physiotherapy and Sports, University College Dublin, D04 C1P1 Dublin, Ireland;
- Insight Centre, University College Dublin, D04 N2E5 Dublin, Ireland
| | - Antonio Cuesta-Vargas
- Grupo Clinimetría en Fisioterapia (CTS 631), Department of Physiotherapy, Faculty of Health Sciences, University of Málaga, 29071 Málaga, Spain; (Á.P.-C.); (J.M.A.)
- Instituto de Investigación Biomédica de Málaga y Plataforma en Nanomedicina (IBIMA Plataforma Bionand) Grupo Clinimetria (F-14), 29590 Málaga, Spain
| |
Collapse
|
6
|
Baker LM, Yawar A, Lieberman DE, Walsh CJ. Predicting overstriding with wearable IMUs during treadmill and overground running. Sci Rep 2024; 14:6347. [PMID: 38491093 PMCID: PMC10942980 DOI: 10.1038/s41598-024-56888-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 03/12/2024] [Indexed: 03/18/2024] Open
Abstract
Running injuries are prevalent, but their exact mechanisms remain unknown largely due to limited real-world biomechanical analysis. Reducing overstriding, the horizontal distance that the foot lands ahead of the body, may be relevant to reducing injury risk. Here, we leverage the geometric relationship between overstriding and lower extremity sagittal segment angles to demonstrate that wearable inertial measurement units (IMUs) can predict overstriding during treadmill and overground running in the laboratory. Ten recreational runners matched their strides to a metronome to systematically vary overstriding during constant-speed treadmill running and showed similar overstriding variation during comfortable-speed overground running. Linear mixed models were used to analyze repeated measures of overstriding and sagittal segment angles measured with motion capture and IMUs. Sagittal segment angles measured with IMUs explained 95% and 98% of the variance in overstriding during treadmill and overground running, respectively. We also found that sagittal segment angles measured with IMUs correlated with peak braking force and explained 88% and 80% of the variance during treadmill and overground running, respectively. This study highlights the potential for IMUs to provide insights into landing and loading patterns over time in real-world running environments, and motivates future research on feedback to modify form and prevent injury.
Collapse
Affiliation(s)
- Lauren M Baker
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, 150 Western Avenue, Boston, MA, 02134, USA
| | - Ali Yawar
- Department of Human Evolutionary Biology, Harvard University, 11 Divinity Avenue, Cambridge, MA, 02138, USA
| | - Daniel E Lieberman
- Department of Human Evolutionary Biology, Harvard University, 11 Divinity Avenue, Cambridge, MA, 02138, USA
| | - Conor J Walsh
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, 150 Western Avenue, Boston, MA, 02134, USA.
| |
Collapse
|
7
|
Liew BXW, Zhu X, Zhai X, McErlain-Naylor SA, McManus C. Association between fat and fat-free body mass indices on shock attenuation during running. J Biomech 2024; 165:112025. [PMID: 38431987 DOI: 10.1016/j.jbiomech.2024.112025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 02/06/2024] [Accepted: 02/22/2024] [Indexed: 03/05/2024]
Abstract
High amplitudes of shock during running have been thought to be associated with an increased injury risk. This study aimed to quantify the association between dual-energy X-ray absorptiometry (DEXA) quantified body composition, and shock attenuation across the time and frequency domains. Twenty-four active adults participated. A DEXA scan was performed to quantify the fat and fat-free mass of the whole-body, trunk, dominant leg, and viscera. Linear accelerations at the tibia, pelvis, and head were collected whilst participants ran on a treadmill at a fixed dimensionless speed 1.00 Fr. Shock attenuation indices in the time- and frequency-domain (lower frequencies: 3-8 Hz; higher frequencies: 9-20 Hz) were calculated. Pearson correlation analysis was performed for all combinations of DEXA and attenuation indices. Regularised regression was performed to predict shock attenuation indices using DEXA variables. A greater power attenuation between the head and pelvis within the higher frequency range was associated with a greater trunk fat-free mass (r = 0.411, p = 0.046), leg fat-free mass (r = 0.524, p = 0.009), and whole-body fat-free mass (r = 0.480, p = 0.018). For power attenuation of the high-frequency component between the pelvis and head, the strongest predictor was visceral fat mass (β = 48.79). Passive and active tissues could represent important anatomical factors aiding in shock attenuation during running. Depending on the type and location of these masses, an increase in mass may benefit injury risk reduction. Also, our findings could implicate the injury risk potential during weight loss programs.
Collapse
Affiliation(s)
- Bernard X W Liew
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, Essex, United Kingdom.
| | - Xuqi Zhu
- School of Computer Science and Electrical Engineering, University of Essex, Colchester, Essex, United Kingdom
| | - Xiaojun Zhai
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom
| | - Stuart A McErlain-Naylor
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, United Kingdom
| | - Christopher McManus
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, Essex, United Kingdom
| |
Collapse
|
8
|
Kiernan D, Katzman ZD, Hawkins DA, Christiansen BA. A 0.05 m Change in Inertial Measurement Unit Placement Alters Time and Frequency Domain Metrics during Running. SENSORS (BASEL, SWITZERLAND) 2024; 24:656. [PMID: 38276348 PMCID: PMC10820910 DOI: 10.3390/s24020656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/12/2024] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
Inertial measurement units (IMUs) provide exciting opportunities to collect large volumes of running biomechanics data in the real world. IMU signals may, however, be affected by variation in the initial IMU placement or movement of the IMU during use. To quantify the effect that changing an IMU's location has on running data, a reference IMU was 'correctly' placed on the shank, pelvis, or sacrum of 74 participants. A second IMU was 'misplaced' 0.05 m away, simulating a 'worst-case' misplacement or movement. Participants ran over-ground while data were simultaneously recorded from the reference and misplaced IMUs. Differences were captured as root mean square errors (RMSEs) and differences in the absolute peak magnitudes and timings. RMSEs were ≤1 g and ~1 rad/s for all axes and misplacement conditions while mean differences in the peak magnitude and timing reached up to 2.45 g, 2.48 rad/s, and 9.68 ms (depending on the axis and direction of misplacement). To quantify the downstream effects of these differences, initial and terminal contact times and vertical ground reaction forces were derived from both the reference and misplaced IMU. Mean differences reached up to -10.08 ms for contact times and 95.06 N for forces. Finally, the behavior in the frequency domain revealed high coherence between the reference and misplaced IMUs (particularly at frequencies ≤~10 Hz). All differences tended to be exaggerated when data were analyzed using a wearable coordinate system instead of a segment coordinate system. Overall, these results highlight the potential errors that IMU placement and movement can introduce to running biomechanics data.
Collapse
Affiliation(s)
- Dovin Kiernan
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
| | - Zachary David Katzman
- Department of Neurobiology, Physiology & Behavior, University of California Davis, Davis, CA 95616, USA
- College of Podiatric Medicine and Surgery, Des Moines University, West Des Moines, IA 50266, USA
| | - David A. Hawkins
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
- Department of Neurobiology, Physiology & Behavior, University of California Davis, Davis, CA 95616, USA
| | - Blaine Andrew Christiansen
- Biomedical Engineering Graduate Group, University of California Davis, Davis, CA 95616, USA (B.A.C.)
- Department of Orthopaedic Surgery, University of California Davis, Davis, CA 95616, USA
| |
Collapse
|
9
|
Huber A, Verhoff D. A One Session Gait Retraining Protocol with Metronome Augmentation Increases Cadence in Novice and Recreational Runners. Int J Sports Phys Ther 2024; 19:1494-1502. [PMID: 38179589 PMCID: PMC10761631 DOI: 10.26603/001c.90909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 11/20/2023] [Indexed: 01/06/2024] Open
Abstract
Background Running is a common leisure physical activity that carries a risk for running related injury (RRI). Non-experienced runners are more likely to sustain RRIs. One form of gait retraining focuses on increasing cadence to improve running biomechanics related to RRI. Protocols for increasing cadence must be pragmatic to be implemented into clinical practice. Hypothesis/Purpose The purpose of this study was to determine if a pragmatic protocol including one instructional session, followed by independent gait retraining with metronome augmentation resulted in increased cadence and altered biomechanics in novice and recreational runners. Study Design Randomized Controlled Trial. Methods Thirty-three novice or recreational adult runners completed a 12 Minute Cooper Run on an indoor track. Variables measured during the 12 Minute Cooper Run included distance, rate of perceived exertion (RPE), heart rate (HR), and 3-D biomechanics using inertial measurement units (IMUs). After baseline testing, the intervention group received instruction and five minutes of gait retraining at a cadence set 5-10% higher than baseline with metronome augmentation (Pro Metronome- Tempo, Beat; by Xiao Yixiang). They then ran two to three times a week for two weeks up to 30 minutes per session with the metronome set at the new cadence. After two weeks, repeat testing using the same protocol was completed. A Mann-Whitney U test analyzed differences between groups. Results Cadence at one minute (p = 0.037) and average cadence over the entire run (p=0.002) increased in the intervention group only with a large effect size (Cohens d = 0.837). No other group differences were found. Conclusion A pragmatic gait retraining protocol with metronome augmentation including one instructional and four to six independent sessions over a two-week duration increased cadence without negative effects on HR, RPE, distance. Biomechanics did not change with this intervention. Further research with pragmatic gait retraining protocols that increase cadence are needed with larger sample sizes, repeated measures over time, across runners of various abilities and experience levels. Level of Evidence Level 2.
Collapse
Affiliation(s)
- Angie Huber
- Doctor of Physical Therapy University of Findlay
| | - Dave Verhoff
- Doctor of Physical Therapy University of Findlay
| |
Collapse
|
10
|
Shao E, Mei Q, Baker JS, Bíró I, Liu W, Gu Y. The effects of non-Newtonian fluid material midsole footwear on tibial shock acceleration and attenuation. Front Bioeng Biotechnol 2023; 11:1276864. [PMID: 38152288 PMCID: PMC10751308 DOI: 10.3389/fbioe.2023.1276864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 11/15/2023] [Indexed: 12/29/2023] Open
Abstract
Introduction: Given the possibility of higher ground temperatures in the future, the pursuit of a cushioning material that can effectively reduce sports injuries during exercise, particularly one that retains its properties at elevated temperatures, has emerged as a serious concern. Methods: A total of 18 man recreational runners were recruited from Ningbo University and local clubs for participation in this study. Frequency analysis was employed to investigate whether there is a distinction between non-Newtonian (NN) shoes and ethylene vinyl acetate (EVA) shoes. Results: The outcomes indicated that the utilization of NN shoes furnished participants with superior cushioning when engaging in a 90° cutting maneuver subsequent to an outdoor exercise, as opposed to the EVA material. Specifically, participants wearing NN shoes exhibited significantly lower peak resultant acceleration (p = 0.022) and power spectral density (p = 0.010) values at the distal tibia compared to those wearing EVA shoes. Moreover, shock attenuation was significantly greater in subjects wearing NN shoes (p = 0.023) in comparison to EVA shoes. Performing 90° cutting maneuver in NN shoes resulted in significantly lower peak ground reaction force (p = 0.010), vertical average loading rate (p < 0.010), and vertical instantaneous loading rate (p = 0.030) values compared to performing the same maneuvers in EVA shoes. Conclusion: The study found that the PRA and PSD of the distal tibia in NN footwear were significantly lower compared to EVA footwear. Additionally, participants exhibited more positive SA while using NN footwear compared to EVA. Furthermore, during the 90° CM, participants wearing NN shoes showed lower PGRF, VAIL, and VILR compared to those in EVA shoes. All these promising results support the capability of NN footwear to offer additional reductions in potential injury risk to runners, especially in high-temperature conditions.
Collapse
Affiliation(s)
- Enze Shao
- Faculty of Sport Science, Ningbo University, Ningbo, China
| | - Qichang Mei
- Faculty of Sport Science, Ningbo University, Ningbo, China
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Julien S. Baker
- Centre for Population Health and Medical Informatics, Hong Kong Baptist University, Kowloon, Hong Kong SAR, China
| | - István Bíró
- Faculty of Engineering, University of Szeged, Szeged, Hungary
| | - Wei Liu
- Faculty of Sport Science, Ningbo University, Ningbo, China
| | - Yaodong Gu
- Faculty of Sport Science, Ningbo University, Ningbo, China
- Department of Radiology, Ningbo No. 2 Hospital, Ningbo, China
| |
Collapse
|
11
|
VAN MIDDELAAR ROBBERTP, ZHANG JUNHAO, VELTINK PETERH, REENALDA JASPER. 3D Tibial Acceleration and Consideration of 3D Angular Motion Using IMUs on Peak Tibial Acceleration and Impulse in Running. Med Sci Sports Exerc 2023; 55:2253-2262. [PMID: 37494829 PMCID: PMC10662620 DOI: 10.1249/mss.0000000000003269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
PURPOSE Peak tibial acceleration (PTA) is defined as the peak acceleration occurring shortly after initial contact, often used as an indirect measure of tibial load. As the tibia is a rotating segment around the ankle, angular velocity and angular acceleration should be included in PTA. This study aimed to quantify three-dimensional tibial acceleration components over two different sensor locations and three running speeds, to get a better understanding of the influence of centripetal and tangential accelerations on PTA typically measured in running. Furthermore, it explores tibial impulse as an alternative surrogate measure for tibial load. METHODS Fifteen participants ran 90 s on a treadmill at 2.8, 3.3, and 3.9 m·s -1 , with inertial measurement units (IMUs) located distally and proximally on the tibia. RESULTS Without the inclusion of rotational accelerations and gravity, no significant difference was found between axial PTA between both IMU locations, whereas in the tangential sagittal plane axis, there was a significant difference. Inclusion of rotational accelerations and gravity resulted in similar PTA estimates at the ankle for both IMU locations and caused a significant difference between PTA based on the distal IMU and PTA at the ankle. The impulse showed more consistent results between the proximal and distal IMU locations compared with axial PTA. CONCLUSIONS Rotational acceleration of the tibia during stance differently impacted PTA measured proximally and distally at the tibia, indicating that rotational acceleration and gravity should be included in PTA estimates. Furthermore, peak acceleration values (such as PTA) are not always reliable when using IMUs because of inconsistent PTA proximally compared with distally on an individual level. Instead, impulse seems to be a more consistent surrogate measure for the tibial load.
Collapse
Affiliation(s)
| | | | | | - JASPER REENALDA
- University of Twente, Enschede, THE NETHERLANDS
- Roessingh Research & Development, Enschede, THE NETHERLANDS
| |
Collapse
|
12
|
Catalá-Vilaplana I, Liu T, Vienneau J, Nigg SR, Pérez-Soriano P, Encarnación-Martínez A. Curved non-motorized treadmills do not biomechanically replicate overground running better than motorized treadmills. J Sports Sci 2023; 41:1927-1933. [PMID: 38258795 DOI: 10.1080/02640414.2024.2307774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Accepted: 01/09/2024] [Indexed: 01/24/2024]
Abstract
The purpose of this study was to determine if curved non-motorized treadmills can reproduce overground running better than motorized treadmills by analysing the differences in joint kinematics (hip, knee, and ankle) using SPM. Nineteen recreational runners completed three randomized running tests on these surfaces. Kinematic data from the hip, knee, and ankle joints were collected. Two-tailed SPM t-tests were performed to analyse time-continuous gait cycles in three anatomical planes of each joint. Higher within-subject variability was observed in the frontal and transverse planes during curved non-motorized treadmill running. SPM analysis showed more significant differences (p < 0.05) between curved non-motorized treadmill and overground than between motorized treadmill and overground, mainly in knee (from 12% to 30% and 93% to 99% of the gait cycle) and ankle (from 19% to 23% of the gait cycle) in the sagittal plane. Therefore, running on curved non-motorized treadmills is more biomechanically different compared to overground than motorized treadmills, and might not be the best strategy to replicate overground running in terms of joint kinematics during highly controlled research studies. However, they could be an interesting tool in rehabilitation or training environments since the changes observed in joint kinematics were likely not functionally relevant.
Collapse
Affiliation(s)
- Ignacio Catalá-Vilaplana
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Tao Liu
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Jordyn Vienneau
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Sandro R Nigg
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Pedro Pérez-Soriano
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| | - Alberto Encarnación-Martínez
- Research Group in Sports Biomechanics (GIBD), Department of Physical Education and Sports, University of Valencia, Valencia, Spain
| |
Collapse
|
13
|
Mason R, Godfrey A, Barry G, Stuart S. Wearables for running gait analysis: A study protocol. PLoS One 2023; 18:e0291289. [PMID: 37695752 PMCID: PMC10495009 DOI: 10.1371/journal.pone.0291289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 08/21/2023] [Indexed: 09/13/2023] Open
Abstract
Quantitative running gait analysis is an important tool that provides beneficial outcomes to injury risk/recovery or performance assessment. Wearable devices have allowed running gait to be evaluated in any environment (i.e., laboratory or real-world settings), yet there are a plethora of different grades of devices (i.e., research-grade, commercial, or novel multi-modal) available with little information to make informed decisions on selection. This paper outlines a protocol that will examine different grades of wearables for running gait analysis in healthy individuals. Specifically, this pilot study will: 1) examine analytical validity and reliability of wearables (research-grade, commercial, high-end multimodal) within a controlled laboratory setting; 2) examine analytical validation of different grades of wearables in a real-world setting, and 3) explore clinical validation and usability of wearables for running gait analysis (e.g., injury history (previously injured, never injured), performance level (novice, elite) and relationship to meaningful outcomes). The different grades of wearable include: (1) A research-grade device, the Ax6 consists of a configurable tri-axial accelerometer and tri-axial gyroscope with variable sampling capabilities; (2) attainable (low-grade) commercial with proprietary software, the DorsaVi ViMove2 consisting of two, non-configurable IMUs modules, with a fixed sampling rate and (3) novel multimodal high-end system, the DANU Sports System that is a pair of textile socks, that contain silicone based capacitive pressure sensors, and configurable IMU modules with variable sampling rates. Clinical trial registration: Trial registration: NCT05277181.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
| | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle, United Kingdom
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle, United Kingdom
- Northumbria Healthcare NHS foundation trust, North Shields, United Kingdom
- Department of Neurology, Oregon Health and Science University, Portland, Oregon, United States of America
| |
Collapse
|
14
|
Darch L, Chalmers S, Causby R, Arnold J. Effect of Running-Induced Fatigue on Tibial Acceleration and the Role of Lower Limb Muscle Strength, Power, and Endurance. Med Sci Sports Exerc 2023; 55:581-589. [PMID: 36251400 DOI: 10.1249/mss.0000000000003062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
BACKGROUND High-impact loads have been linked with running injuries. Fatigue has been proposed to increase impact loads, but this relationship has not been rigorously examined, including the associated role of muscle strength, power, and endurance. PURPOSE This study aimed to investigate the effect of fatigue on impact loading in runners and the role of muscle function in mediating changes in impact loading with fatigue. METHODS Twenty-eight trained endurance runners performed a fixed-intensity time to exhaustion test at 85% of V̇O 2max . Tibial accelerations were measured using leg-mounted inertial measurement units and sampled every minute until volitional exhaustion. Tests of lower limb muscle strength, power, and endurance included maximal isometric strength (soleus, knee extensors, and knee flexors), single leg hop for distance, and the one leg rise test. Changes in peak tibial acceleration (PTA, g ) were compared between time points throughout the run (0%, 25%, 50%, 75%, and 100%). Associations between the change in PTA and lower limb muscle function tests were assessed (Spearman's rho [ rs ]). RESULTS PTA increased over the duration of the fatiguing run. Compared with baseline (0%) (mean ± SD, 9.1 g ± 1.6 g ), there was a significant increase at 75% (9.9 g ± 1.7 g , P = 0.001) and 100% (10.1 g ± 1.8 g , P < 0.001), with no change at 25% (9.6 g ± 1.6 g , P = 0.142) or 50% (9.7 g ± 1.7 g , P = 0.053). Relationships between change in PTA and muscle function tests were weak and not statistically significant ( rs = -0.153 to 0.142, all P > 0.05). CONCLUSIONS Peak axial tibial acceleration increased throughout a fixed-intensity run to exhaustion. The change in PTA was not related to performance in lower limb muscle function tests.
Collapse
Affiliation(s)
- Lachlan Darch
- Alliance for Research in Exercise, Nutrition and Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, South Australia, AUSTRALIA
| | | | | | | |
Collapse
|
15
|
A Minimal Sensor Inertial Measurement Unit System Is Replicable and Capable of Estimating Bilateral Lower-Limb Kinematics in a Stationary Bodyweight Squat and a Countermovement Jump. J Appl Biomech 2023; 39:42-53. [PMID: 36652950 DOI: 10.1123/jab.2022-0168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 11/20/2022] [Accepted: 11/29/2022] [Indexed: 01/19/2023]
Abstract
This study aimed to validate a 7-sensor inertial measurement unit system against optical motion capture to estimate bilateral lower-limb kinematics. Hip, knee, and ankle sagittal plane peak angles and range of motion (ROM) were compared during bodyweight squats and countermovement jumps in 18 participants. In the bodyweight squats, left peak hip flexion (intraclass correlation coefficient [ICC] = .51), knee extension (ICC = .68) and ankle plantar flexion (ICC = .55), and hip (ICC = .63) and knee (ICC = .52) ROM had moderate agreement, and right knee ROM had good agreement (ICC = .77). Relatively higher agreement was observed in the countermovement jumps compared to the bodyweight squats, moderate to good agreement in right peak knee flexion (ICC = .73), and right (ICC = .75) and left (ICC = .83) knee ROM. Moderate agreement was observed for right ankle plantar flexion (ICC = .63) and ROM (ICC = .51). Moderate agreement (ICC > .50) was observed in all variables in the left limb except hip extension, knee flexion, and dorsiflexion. In general, there was poor agreement for peak flexion angles, and at least moderate agreement for joint ROM. Future work will aim to optimize methodologies to increase usability and confidence in data interpretation by minimizing variance in system-based differences and may also benefit from expanding planes of movement.
Collapse
|
16
|
Dorschky E, Camomilla V, Davis J, Federolf P, Reenalda J, Koelewijn AD. Perspective on "in the wild" movement analysis using machine learning. Hum Mov Sci 2023; 87:103042. [PMID: 36493569 DOI: 10.1016/j.humov.2022.103042] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 09/01/2022] [Accepted: 11/19/2022] [Indexed: 12/12/2022]
Abstract
Recent advances in wearable sensing and machine learning have created ample opportunities for "in the wild" movement analysis in sports, since the combination of both enables real-time feedback to be provided to athletes and coaches, as well as long-term monitoring of movements. The potential for real-time feedback is useful for performance enhancement or technique analysis, and can be achieved by training efficient models and implementing them on dedicated hardware. Long-term monitoring of movement can be used for injury prevention, among others. Such applications are often enabled by training a machine learned model from large datasets that have been collected using wearable sensors. Therefore, in this perspective paper, we provide an overview of approaches for studies that aim to analyze sports movement "in the wild" using wearable sensors and machine learning. First, we discuss how a measurement protocol can be set up by answering six questions. Then, we discuss the benefits and pitfalls and provide recommendations for effective training of machine learning models from movement data, focusing on data pre-processing, feature calculation, and model selection and tuning. Finally, we highlight two application domains where "in the wild" data recording was combined with machine learning for injury prevention and technique analysis, respectively.
Collapse
Affiliation(s)
- Eva Dorschky
- Machine Learning and Data Analytics (MaD) Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Valentina Camomilla
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", Rome, Italy
| | - Jesse Davis
- Department of Computer Science and Leuven.AI, KU Leuven, Leuven, Belgium
| | - Peter Federolf
- Department of Sport Science, University of Innsbruck, Innsbruck, Austria
| | - Jasper Reenalda
- Biomedical Signal and Systems group, University of Twente, Enschede, The Netherlands; Roessingh Research and Development, Enschede, The Netherlands
| | - Anne D Koelewijn
- Machine Learning and Data Analytics (MaD) Lab, Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
| |
Collapse
|
17
|
Zandbergen MA, Ter Wengel XJ, van Middelaar RP, Buurke JH, Veltink PH, Reenalda J. Peak tibial acceleration should not be used as indicator of tibial bone loading during running. Sports Biomech 2023:1-18. [PMID: 36645012 DOI: 10.1080/14763141.2022.2164345] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 12/27/2022] [Indexed: 01/17/2023]
Abstract
Peak tibial acceleration (PTA) is a widely used indicator of tibial bone loading. Indirect bone loading measures are of interest to reduce the risk of stress fractures during running. However, tibial compressive forces are caused by both internal muscle forces and external ground reaction forces. PTA might reflect forces from outside the body, but likely not the compressive force from muscles on the tibial bone. Hence, the strength of the relationship between PTA and maximum tibial compression forces in rearfoot-striking runners was investigated. Twelve runners ran on an instrumented treadmill while tibial acceleration was captured with accelerometers. Force plate and inertial measurement unit data were spatially aligned with a novel method based on the centre of pressure crossing a virtual toe marker. The correlation coefficient between maximum tibial compression forces and PTA was 0.04 ± 0.14 with a range of -0.15 to +0.28. This study showed a very weak and non-significant correlation between PTA and maximum tibial compression forces while running on a level treadmill at a single speed. Hence, PTA as an indicator for tibial bone loading should be reconsidered, as PTA does not provide a complete picture of both internal and external compressive forces on the tibial bone. .
Collapse
Affiliation(s)
- Marit A Zandbergen
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, The Netherlands
| | - Xanthe J Ter Wengel
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
| | - Robbert P van Middelaar
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
| | - Jaap H Buurke
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, The Netherlands
| | - Peter H Veltink
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
| | - Jasper Reenalda
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, Enschede, The Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, The Netherlands
| |
Collapse
|
18
|
Zandbergen MA, Buurke JH, Veltink PH, Reenalda J. Quantifying and correcting for speed and stride frequency effects on running mechanics in fatiguing outdoor running. Front Sports Act Living 2023; 5:1085513. [PMID: 37139307 PMCID: PMC10150107 DOI: 10.3389/fspor.2023.1085513] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 02/23/2023] [Indexed: 05/05/2023] Open
Abstract
Measuring impact-related quantities in running is of interest to improve the running technique. Many quantities are typically measured in a controlled laboratory setting, even though most runners run in uncontrolled outdoor environments. While monitoring running mechanics in an uncontrolled environment, a decrease in speed or stride frequency can mask fatigue-related changes in running mechanics. Hence, this study aimed to quantify and correct the subject-specific effects of running speed and stride frequency on changes in impact-related running mechanics during a fatiguing outdoor run. Seven runners ran a competitive marathon while peak tibial acceleration and knee angles were measured with inertial measurement units. Running speed was measured through sports watches. Median values over segments of 25 strides throughout the marathon were computed and used to create subject-specific multiple linear regression models. These models predicted peak tibial acceleration, knee angles at initial contact, and maximum stance phase knee flexion based on running speed and stride frequency. Data were corrected for individual speed and stride frequency effects during the marathon. The speed and stride frequency corrected and uncorrected data were divided into ten stages to investigate the effect of marathon stage on mechanical quantities. This study showed that running speed and stride frequency explained, on average, 20%-30% of the variance in peak tibial acceleration, knee angles at initial contact, and maximum stance phase knee angles while running in an uncontrolled setting. Regression coefficients for speed and stride frequency varied strongly between subjects. Speed and stride frequency corrected peak tibial acceleration, and maximum stance phase knee flexion increased throughout the marathon. At the same time, uncorrected maximum stance phase knee angles showed no significant differences between marathon stages due to a decrease in running speed. Hence, subject-specific effects of changes in speed and stride frequency influence the interpretation of running mechanics and are relevant when monitoring, or comparing the gait pattern between runs in uncontrolled environments.
Collapse
Affiliation(s)
- Marit A. Zandbergen
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, Netherlands
- Correspondence: Marit A. Zandbergen
| | - Jaap H. Buurke
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, Netherlands
| | - Peter H. Veltink
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
| | - Jasper Reenalda
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, Netherlands
- Department of Rehabilitation Technology, Roessingh Research and Development, Enschede, Netherlands
| |
Collapse
|
19
|
Mason R, Pearson LT, Barry G, Young F, Lennon O, Godfrey A, Stuart S. Wearables for Running Gait Analysis: A Systematic Review. Sports Med 2023; 53:241-268. [PMID: 36242762 PMCID: PMC9807497 DOI: 10.1007/s40279-022-01760-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2022] [Indexed: 01/12/2023]
Abstract
BACKGROUND Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance. OBJECTIVES We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults. METHODS A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings. RESULTS A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards. CONCLUSIONS This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes. CLINICAL TRIAL REGISTRATION CRD42021235527.
Collapse
Affiliation(s)
- Rachel Mason
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Liam T Pearson
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Gillian Barry
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Fraser Young
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | | | - Alan Godfrey
- Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - Samuel Stuart
- Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK.
- Northumbria Healthcare NHS Foundation Trust, Newcastle upon Tyne, UK.
| |
Collapse
|
20
|
Zandbergen MA, Marotta L, Bulthuis R, Buurke JH, Veltink PH, Reenalda J. Effects of level running-induced fatigue on running kinematics: A systematic review and meta-analysis. Gait Posture 2023; 99:60-75. [PMID: 36332318 DOI: 10.1016/j.gaitpost.2022.09.089] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 07/15/2022] [Accepted: 09/19/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Runners have a high risk of acquiring a running-related injury. Understanding the mechanisms of impact force attenuation into the body when a runner fatigues might give insight into the role of running kinematics on the aetiology of overuse injuries. RESEARCH QUESTIONS How do running kinematics change due to running-induced fatigue? And what is the influence of experience level on changes in running kinematics due to fatigue? METHODS Three electronic databases were searched: PubMed, Web of Science, and Scopus. This resulted in 33 articles and 19 kinematic quantities being included in this review. A quality assessment was performed on all included articles and meta-analyses were performed for 18 kinematic quantities. RESULTS AND SIGNIFICANCE Main findings included an increase in peak acceleration at the tibia and a decrease in leg stiffness after a fatiguing protocol. Additionally, level running-induced fatigue increased knee flexion at initial contact and maximum knee flexion during swing. An increase in vertical centre of mass displacement was found in novice but not in experienced runners with fatigue. Overall, runners changed their gait pattern due to fatigue by moving to a smoother gait pattern (i.e. more knee flexion at initial contact and during swing, decreased leg stiffness). However, these changes were not sufficient to prevent an increase in peak accelerations at the tibia after a fatigue protocol. Large inter-individual differences in responses to fatigue were reported. Hence, it is recommended to investigate changes in running kinematics as a result of fatigue on a subject-specific level since group-level analysis might mask individual responses.
Collapse
Affiliation(s)
- Marit A Zandbergen
- Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands; Rehabilitation Technology, Roessingh Research and Development, Enschede, the Netherlands.
| | - Luca Marotta
- Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands; Rehabilitation Technology, Roessingh Research and Development, Enschede, the Netherlands
| | - Roos Bulthuis
- Rehabilitation Technology, Roessingh Research and Development, Enschede, the Netherlands
| | - Jaap H Buurke
- Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands; Rehabilitation Technology, Roessingh Research and Development, Enschede, the Netherlands
| | - Peter H Veltink
- Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands
| | - Jasper Reenalda
- Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands; Rehabilitation Technology, Roessingh Research and Development, Enschede, the Netherlands
| |
Collapse
|
21
|
Panday SB, Pathak P, Moon J, Koo D. Complexity of Running and Its Relationship with Joint Kinematics during a Prolonged Run. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:9656. [PMID: 35955013 PMCID: PMC9368290 DOI: 10.3390/ijerph19159656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/30/2022] [Accepted: 08/03/2022] [Indexed: 06/15/2023]
Abstract
We investigated the effect of prolonged running on joint kinematics and its association with stride complexity between novice and elite runners. Ten elite marathoners and eleven healthy individuals took part in a 20 min submaximal prolonged running experiment at their preferred running speed (PRS). A three-dimensional motion capture system was utilized to capture and calculate the alpha exponent, stride-to-stride fluctuations (SSFs), and stride-to-stride variability (SSV) of spatiotemporal parameters and joint kinematics. In the results, the elite athletes ran at a considerably higher PRS than the novice runners, yet no significant differences were found in respiratory exchange ratio with increasing time intervals. For the spatiotemporal parameters, we observed a significant increase in the step width and length variability in novice runners with increasing time-interval (p < 0.05). However, we did not observe any differences in the alpha exponent of spatiotemporal parameters. Significant differences in SSF of joint kinematics were observed, particularly in the sagittal plane for ankle, knee, and hip at heel strike (p < 0.05). While in mid-stance, time-interval differences were observed in novices who ran with a lower knee flexion angle (p < 0.05). During toe-off, significantly higher SSV was observed, particularly in the hip and ankle for novices (p < 0.05). The correlation analysis of joint SSV revealed a distinct negative relationship with the alpha exponent of step-length and step-width for elite runners, while, for novices, a positive relation was observed only for the alpha exponent of step-width. In conclusion, our study shows that increased step-width variability seen in novices could be a compensatory mechanism to maintain performance and mitigate the loss of stability. On the other hand, elite runners showed a training-induced effective modulation of lower-limb kinematics to improve their running performance.
Collapse
Affiliation(s)
| | - Prabhat Pathak
- Department of Physical Education, Seoul National University, Seoul 08826, Korea
| | - Jeheon Moon
- Department of Physical Education, Korea National University of Education, Cheongju-si 28173, Korea
| | - Dohoon Koo
- Department of Exercise Prescription, College of Medical Science, Jeonju University, Jeonju 55069, Korea
| |
Collapse
|
22
|
Xiang L, Gu Y, Rong M, Gao Z, Yang T, Wang A, Shim V, Fernandez J. Shock Acceleration and Attenuation during Running with Minimalist and Maximalist Shoes: A Time- and Frequency-Domain Analysis of Tibial Acceleration. Bioengineering (Basel) 2022; 9:bioengineering9070322. [PMID: 35877373 PMCID: PMC9312333 DOI: 10.3390/bioengineering9070322] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/11/2022] [Accepted: 07/14/2022] [Indexed: 12/29/2022] Open
Abstract
Tibial shock attenuation is part of the mechanism that maintains human body stabilization during running. It is crucial to understand how shock characteristics transfer from the distal to proximal joint in the lower limb. This study aims to investigate the shock acceleration and attenuation among maximalist shoes (MAXs), minimalist shoes (MINs), and conventional running shoes (CONs) in time and frequency domains. Time-domain parameters included time to peak acceleration and peak resultant acceleration, and frequency-domain parameters contained lower (3−8 Hz) and higher (9−20 Hz) frequency power spectral density (PSD) and shock attenuation. Compared with CON and MAX conditions, MINs significantly increased the peak impact acceleration of the distal tibia (p = 0.01 and p < 0.01). Shock attenuation in the lower frequency depicted no difference but was greater in the MAXs in the higher frequency compared with the MIN condition (p < 0.01). MINs did not affect the tibial shock in both time and frequency domains at the proximal tibia. These findings may provide tibial shock information for choosing running shoes and preventing tibial stress injuries.
Collapse
Affiliation(s)
- Liangliang Xiang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (L.X.); (Z.G.); (T.Y.)
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand; (A.W.); (V.S.); (J.F.)
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (L.X.); (Z.G.); (T.Y.)
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand; (A.W.); (V.S.); (J.F.)
- Correspondence: (Y.G.); (M.R.); Tel.: +86-574-8760-9369 (Y.G.)
| | - Ming Rong
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (L.X.); (Z.G.); (T.Y.)
- Correspondence: (Y.G.); (M.R.); Tel.: +86-574-8760-9369 (Y.G.)
| | - Zixiang Gao
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (L.X.); (Z.G.); (T.Y.)
- Faculty of Engineering, University of Pannonia, H-8201 Veszprém, Hungary
| | - Tao Yang
- Faculty of Sports Science, Ningbo University, Ningbo 315211, China; (L.X.); (Z.G.); (T.Y.)
| | - Alan Wang
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand; (A.W.); (V.S.); (J.F.)
- Faculty of Medical and Health Sciences, The University of Auckland, Auckland 1010, New Zealand
| | - Vickie Shim
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand; (A.W.); (V.S.); (J.F.)
| | - Justin Fernandez
- Auckland Bioengineering Institute, The University of Auckland, Auckland 1010, New Zealand; (A.W.); (V.S.); (J.F.)
- Department of Engineering Science, Faculty of Engineering, The University of Auckland, Auckland 1010, New Zealand
| |
Collapse
|
23
|
Lloria-Varella J, Besson T, Varesco G, Espeit L, Kennouche D, Delattre N, Millet GY, Morio C, Rossi J. Running pattern changes after a 38-km trail running race: does shoe fatigue play a role? FOOTWEAR SCIENCE 2022. [DOI: 10.1080/19424280.2022.2086302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Jaume Lloria-Varella
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| | - Thibault Besson
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| | - Giorgio Varesco
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| | - Loïc Espeit
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| | - Djahid Kennouche
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| | | | - Guillaume Y. Millet
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
- Institut Universitaire de France (IUF), Paris, France
| | - Cedric Morio
- Movement Sciences Department, SportsLab, Lille, France
| | - Jeremy Rossi
- Laboratoire Interuniversitaire de Biologie de la Motricité, Université Lyon, UJM-Saint-Etienne, Saint-Etienne, France
| |
Collapse
|
24
|
Darch L, Chalmers S, Wiltshire J, Causby R, Arnold J. Running-induced fatigue and impact loading in runners: A systematic review and meta-analysis. J Sports Sci 2022; 40:1512-1531. [PMID: 35723671 DOI: 10.1080/02640414.2022.2089803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
This systematic review and meta-analysis aimed to synthesise and clarify the effect of running-induced fatigue on impact loading during running. Eight electronic databases were systematically searched until April 2021. Studies that analysed impact loading over the course of a run, in adult runners free of medical conditions were included. Changes in leg stiffness, vertical stiffness, shock attenuation, peak tibial accelerations, peak ground reaction forces (GRF) and loading rates were extracted. Subgroup analyses were conducted depending on whether participants were required to run to exhaustion. Thirty-six studies were included in the review, 25 were included in the meta-analysis. Leg stiffness decreased with running-induced fatigue (SMD -0.31, 95% CI -0.52, -0.08, moderate evidence). Exhaustive and non-exhaustive subgroups were different for peak tibial acceleration (Chi2 = 3.79, p = 0.05), with limited evidence from exhaustive subgroups showing an increase in peak tibial acceleration with fatigue. Findings for vertical GRF impact peak and peak braking force were conflicting based on exhaustive and non-exhaustive protocols (Chi2 = 3.83, p = 0.05 and Chi2 = 5.10, p = 0.02, respectively). Moderate evidence suggests leg stiffness during running decreases with fatigue. Given the non-linear relationship between leg stiffness and running economy, this may have implications for performance.
Collapse
Affiliation(s)
- Lachlan Darch
- Alliance for Research in Exercise, Nutrition & Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia
| | - Samuel Chalmers
- Alliance for Research in Exercise, Nutrition & Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia
| | - James Wiltshire
- Alliance for Research in Exercise, Nutrition & Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia
| | - Ryan Causby
- Alliance for Research in Exercise, Nutrition & Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia
| | - John Arnold
- Alliance for Research in Exercise, Nutrition & Activity (ARENA), Allied Health and Human Performance, University of South Australia, Adelaide, Australia
| |
Collapse
|
25
|
Burke A, Dillon S, O'Connor S, Whyte EF, Gore S, Moran KA. Relative and absolute reliability of shank and sacral running impact accelerations over a short- and long-term time frame. Sports Biomech 2022:1-16. [PMID: 35699677 DOI: 10.1080/14763141.2022.2086169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 05/31/2022] [Indexed: 10/18/2022]
Abstract
Whilst running is hugely popular, running-related injuries (RRIs) are prevalent. High impact loading has been proposed to contribute to RRIs, with accelerometers becoming increasingly popular in estimating segmental loading for injury detection and biofeedback training. However, there is a lack of research examining the reliability of measures of impact acceleration across short- and long-term time periods, both prior to and following exerted running. The aim of this study was to assess the absolute and relative reliability of shank and sacral impact accelerations over a short- and long-term time period. Peak (Peakaccel) and rate (Rateaccel) of impact acceleration at the shank and sacrum were assessed in 18 recreational runners over short- and long-term time frames, across fixed and self-selected speeds. The relative and absolute reliabilities were investigated for pre- and post-exerted states of running. There was high-to-excellent relative reliability, and predominantly moderate absolute reliability for shank and sacrum Peakaccel and Rateaccel in the short- and long-term time frames between pre- and post-exerted states. High to excellent relative reliability of Peakaccel and Rateaccel at the shank and sacrum are appropriate and acceptable measures across short- and long-term time frames. These findings were consistent with different levels of speed and exertion. The minimal detectable change % was large for both sensors and associated measurements, indicating that their use may be limited to intervention studies that elicit large change (>30%) in these measures.
Collapse
Affiliation(s)
- Aoife Burke
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Insight SFI Research Centre for Data Analytics, Dublin City University, Dublin, Ireland
| | - Sarah Dillon
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Insight SFI Research Centre for Data Analytics, Dublin City University, Dublin, Ireland
| | - Siobhán O'Connor
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Centre for Injury Prevention and Performance, Athletic Therapy and Training, Dublin City University, Dublin, Ireland
| | - Enda F Whyte
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Centre for Injury Prevention and Performance, Athletic Therapy and Training, Dublin City University, Dublin, Ireland
| | - Shane Gore
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Insight SFI Research Centre for Data Analytics, Dublin City University, Dublin, Ireland
| | - Kieran A Moran
- School of Health and Human Performance, Dublin City University, Dublin, Ireland
- Insight SFI Research Centre for Data Analytics, Dublin City University, Dublin, Ireland
- Centre for Injury Prevention and Performance, Athletic Therapy and Training, Dublin City University, Dublin, Ireland
| |
Collapse
|
26
|
Glassbrook DJ, Fuller JT, Alderson JA, Wills JA, Doyle TLA. Changes in acceleration load as measured by inertial measurement units manifest in the upper body after an extended running task. J Sports Sci 2022; 40:1467-1475. [PMID: 35675331 DOI: 10.1080/02640414.2022.2086520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The purpose of this study was to investigate the behaviour of physiological load measures as well as ground reaction forces (GRF) and acceleration load during a prolonged running task that simulated the running demands of an intermittent team sport. Nineteen males completed a maximal aerobic fitness test and an extended running protocol across two sessions. Participants wore a portable metabolic system, and four inertial measurement units (IMU), one on each foot, the lower back and upper back. GRF were measured via an instrumented treadmill. Change in metabolic, IMU and GRF variables across five blocks during the running protocol were assessed using a one-way repeated measures ANOVA. The running protocol elicited large increases in heart rate and oxygen consumption over time. No statistically significant changes in any peak impact accelerations were observed. Resultant acceleration area under the curve (AUC) increased at the lower and upper back locations but was unchanged at the foot. GRF active peak but not impact peak increased during the prolonged run. The results of this study indicate that the effect of an extended running task on IMU measures of external mechanical load is manifested in the upper body, and is effectively measured by AUC.
Collapse
Affiliation(s)
- Daniel J Glassbrook
- Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Joel T Fuller
- Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | | | - Jodie A Wills
- Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| | - Tim L A Doyle
- Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
27
|
Rahlf AL, Hoenig T, Stürznickel J, Cremans K, Fohrmann D, Sanchez-Alvarado A, Rolvien T, Hollander K. A machine learning approach to identify risk factors for running-related injuries: study protocol for a prospective longitudinal cohort trial. BMC Sports Sci Med Rehabil 2022; 14:75. [PMID: 35473813 PMCID: PMC9040327 DOI: 10.1186/s13102-022-00426-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 02/23/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND Running is a very popular sport among both recreational and competitive athletes. However, participating in running is associated with a comparably high risk of sustaining an exercise-related injury. Due to the often multifactorial and individual reasons for running injuries, a shift in thinking is required to account for the dynamic process of the various risk factors. Therefore, a machine learning approach will be used to comprehensively analyze biomechanical, biological, and loading parameters in order to identify risk factors and to detect risk patterns in runners. METHODS The prospective longitudinal cohort study will include competitive adult athletes, running at least 20 km per week and being free of injuries three months before the start of the study. At baseline and the end of the study period, subjective questionnaires (demographics, injury history, sports participation, menstruation, medication, psychology), biomechanical measures (e.g., stride length, cadence, kinematics, kinetics, tibial shock, and tibial acceleration) and a medical examination (BMI, laboratory: blood count, creatinine, calcium, phosphate, parathyroid hormone, vitamin D, osteocalcin, bone-specific alkaline phosphatase, DPD cross-links) will be performed. During the study period (one season), continuous data collection will be performed for biomechanical parameters, injuries, internal and external load. Statistical analysis of the data is performed using machine learning (ML) methods. For this purpose, the correlation of the collected data to possible injuries is automatically learned by an ML model and from this, a ranking of the risk factors can be determined with the help of sensitivity analysis methods. DISCUSSION To achieve a comprehensive risk reduction of injuries in runners, a multifactorial and individual approach and analysis is necessary. Recently, the use of ML processes for the analysis of risk factors in sports was discussed and positive results have been published. This study will be the first prospective longitudinal cohort study in runners to investigate the association of biomechanical, bone health, and loading parameters as well as injuries via ML models. The results may help to predict the risk of sustaining an injury and give way for new analysis methods that may also be transferred to other sports. TRIAL REGISTRATION DRKS00026904 (German Clinical Trial Register DKRS), date of registration 18.10.2021.
Collapse
Affiliation(s)
- A L Rahlf
- Department of Sports Science, Institute of Health, Nutrition and Sports Science, Europa-Universität Flensburg, Campusallee 2, 24943, Flensburg, Germany.
| | - T Hoenig
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - J Stürznickel
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.,Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - K Cremans
- Department of Mechanical Engineering, Institute of Modelling and High-Performance Computing, Niederrhein University of Applied Sciences, Reinarzstraße 49, 47805, Krefeld, Germany
| | - D Fohrmann
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Am Kaiserkai 1, 20457, Hamburg, Germany
| | - A Sanchez-Alvarado
- Department of Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, Turmweg 2, 20148, Hamburg, Germany
| | - T Rolvien
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - K Hollander
- Institute of Interdisciplinary Exercise Science and Sports Medicine, MSH Medical School Hamburg, Am Kaiserkai 1, 20457, Hamburg, Germany
| |
Collapse
|
28
|
Preatoni E, Bergamini E, Fantozzi S, Giraud LI, Orejel Bustos AS, Vannozzi G, Camomilla V. The Use of Wearable Sensors for Preventing, Assessing, and Informing Recovery from Sport-Related Musculoskeletal Injuries: A Systematic Scoping Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:3225. [PMID: 35590914 PMCID: PMC9105988 DOI: 10.3390/s22093225] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/13/2022] [Accepted: 04/18/2022] [Indexed: 02/06/2023]
Abstract
Wearable technologies are often indicated as tools that can enable the in-field collection of quantitative biomechanical data, unobtrusively, for extended periods of time, and with few spatial limitations. Despite many claims about their potential for impact in the area of injury prevention and management, there seems to be little attention to grounding this potential in biomechanical research linking quantities from wearables to musculoskeletal injuries, and to assessing the readiness of these biomechanical approaches for being implemented in real practice. We performed a systematic scoping review to characterise and critically analyse the state of the art of research using wearable technologies to study musculoskeletal injuries in sport from a biomechanical perspective. A total of 4952 articles were retrieved from the Web of Science, Scopus, and PubMed databases; 165 were included. Multiple study features-such as research design, scope, experimental settings, and applied context-were summarised and assessed. We also proposed an injury-research readiness classification tool to gauge the maturity of biomechanical approaches using wearables. Five main conclusions emerged from this review, which we used as a springboard to propose guidelines and good practices for future research and dissemination in the field.
Collapse
Affiliation(s)
- Ezio Preatoni
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
- Centre for Health and Injury and Illness Prevention in Sport, University of Bath, Bath BA2 7AY, UK
| | - Elena Bergamini
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Silvia Fantozzi
- Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy;
- Health Sciences and Technologies—Interdepartmental Centre for Industrial Research, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy
| | - Lucie I. Giraud
- Department for Health, University of Bath, Bath BA2 7AY, UK; (E.P.); (L.I.G.)
| | - Amaranta S. Orejel Bustos
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Giuseppe Vannozzi
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| | - Valentina Camomilla
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy; (E.B.); (A.S.O.B.); (V.C.)
- Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. de Bosis 6, 00135 Rome, Italy
| |
Collapse
|
29
|
Marotta L, Scheltinga BL, van Middelaar R, Bramer WM, van Beijnum BJF, Reenalda J, Buurke JH. Accelerometer-Based Identification of Fatigue in the Lower Limbs during Cyclical Physical Exercise: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:3008. [PMID: 35458993 PMCID: PMC9025833 DOI: 10.3390/s22083008] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 02/01/2023]
Abstract
Physical exercise (PE) is beneficial for both physical and psychological health aspects. However, excessive training can lead to physical fatigue and an increased risk of lower limb injuries. In order to tailor training loads and durations to the needs and capacities of an individual, physical fatigue must be estimated. Different measurement devices and techniques (i.e., ergospirometers, electromyography, and motion capture systems) can be used to identify physical fatigue. The field of biomechanics has succeeded in capturing changes in human movement with optical systems, as well as with accelerometers or inertial measurement units (IMUs), the latter being more user-friendly and adaptable to real-world scenarios due to its wearable nature. There is, however, still a lack of consensus regarding the possibility of using biomechanical parameters measured with accelerometers to identify physical fatigue states in PE. Nowadays, the field of biomechanics is beginning to open towards the possibility of identifying fatigue state using machine learning algorithms. Here, we selected and summarized accelerometer-based articles that either (a) performed analyses of biomechanical parameters that change due to fatigue in the lower limbs or (b) performed fatigue identification based on features including biomechanical parameters. We performed a systematic literature search and analysed 39 articles on running, jumping, walking, stair climbing, and other gym exercises. Peak tibial and sacral acceleration were the most common measured variables and were found to significantly increase with fatigue (respectively, in 6/13 running articles and 2/4 jumping articles). Fatigue classification was performed with an accuracy between 78% and 96% and Pearson's correlation with an RPE (rate of perceived exertion) between r = 0.79 and r = 0.95. We recommend future effort toward the standardization of fatigue protocols and methods across articles in order to generalize fatigue identification results and increase the use of accelerometers to quantify physical fatigue in PE.
Collapse
Affiliation(s)
- Luca Marotta
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Bouke L. Scheltinga
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Robbert van Middelaar
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Wichor M. Bramer
- Medical Library, Erasmus University Medical Center, 3000 CA Rotterdam, The Netherlands;
| | - Bert-Jan F. van Beijnum
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Jasper Reenalda
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
| | - Jaap H. Buurke
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (B.L.S.); (J.R.); (J.H.B.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (R.v.M.); (B.-J.F.v.B.)
- Roessingh Rehabilitation Centre, 7522 AH Enschede, The Netherlands
| |
Collapse
|
30
|
Use of Wearable Technology to Measure Activity in Orthopaedic Trauma Patients: A Systematic Review. Indian J Orthop 2022; 56:1112-1122. [PMID: 35813536 PMCID: PMC9232686 DOI: 10.1007/s43465-022-00629-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 03/18/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Patient-Reported Outcome Measures (PROMs) are widely used for measurement of functional outcomes after orthopaedic trauma. However, PROMs rely on patient collaboration and suffer from various types of bias. Wearable Activity Monitors (WAMs) are increasingly used to objectify functional assessment. The objectives of this systematic review were to identify and characterise the WAMs technology and metrics currently used for orthopaedic trauma research. METHODS PubMed and Embase biomedical literature search engines were queried. Eligibility criteria included: Human clinical studies published in the English language between 2010 and 2019 involving fracture management and WAMs. Variables collected from each article included: Technology used, vendor/product, WAM body location, metrics measured, measurement time period, year of publication, study geographic location, phase of treatment studied, fractures studied, number of patients studied, sex and age of the study subjects, and study level of evidence. Six investigators reviewed the resulting papers. Descriptive statistics of variables of interest were used to analyse the data. RESULTS One hundred and thirty-six papers were available for analysis, showing an increasing trend of publications per year. Accelerometry followed by plantar pressure insoles were the most commonly employed technologies. The most common location for WAM placement was insoles, followed by the waist. The most commonly studied fracture type was hip fractures followed by fragility fractures in general, ankle, "lower extremity", and tibial fractures. The rehabilitation phase following surgery was the most commonly studied period. Sleep duration, activity time or step counts were the most commonly reported WAM metrics. A preferred, clinically validated WAM metric was not identified. CONCLUSIONS WAMs have an increasing presence in the orthopaedic trauma literature. The optimal implementation of this technology and its use to understand patients' pre-injury and post-injury functions is currently insufficiently explored and represents an area that will benefit from future study. SYSTEMATIC REVIEW REGISTRATION NUMBER PROSPERO ID:210344. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s43465-022-00629-0.
Collapse
|
31
|
Benson LC, Räisänen AM, Clermont CA, Ferber R. Is This the Real Life, or Is This Just Laboratory? A Scoping Review of IMU-Based Running Gait Analysis. SENSORS 2022; 22:s22051722. [PMID: 35270869 PMCID: PMC8915128 DOI: 10.3390/s22051722] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 01/19/2023]
Abstract
Inertial measurement units (IMUs) can be used to monitor running biomechanics in real-world settings, but IMUs are often used within a laboratory. The purpose of this scoping review was to describe how IMUs are used to record running biomechanics in both laboratory and real-world conditions. We included peer-reviewed journal articles that used IMUs to assess gait quality during running. We extracted data on running conditions (indoor/outdoor, surface, speed, and distance), device type and location, metrics, participants, and purpose and study design. A total of 231 studies were included. Most (72%) studies were conducted indoors; and in 67% of all studies, the analyzed distance was only one step or stride or <200 m. The most common device type and location combination was a triaxial accelerometer on the shank (18% of device and location combinations). The most common analyzed metric was vertical/axial magnitude, which was reported in 64% of all studies. Most studies (56%) included recreational runners. For the past 20 years, studies using IMUs to record running biomechanics have mainly been conducted indoors, on a treadmill, at prescribed speeds, and over small distances. We suggest that future studies should move out of the lab to less controlled and more real-world environments.
Collapse
Affiliation(s)
- Lauren C. Benson
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Tonal Strength Institute, Tonal, San Francisco, CA 94107, USA
- Correspondence:
| | - Anu M. Räisänen
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Department of Physical Therapy Education, College of Health Sciences—Northwest, Western University of Health Sciences, Lebanon, OR 97355, USA
| | - Christian A. Clermont
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Sport Product Testing, Canadian Sport Institute Calgary, Calgary, AB T3B 6B7, Canada
| | - Reed Ferber
- Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.M.R.); (C.A.C.); (R.F.)
- Cumming School of Medicine, Faculty of Nursing, University of Calgary, Calgary, AB T2N 1N4, Canada
- Running Injury Clinic, Calgary, AB T2N 1N4, Canada
| |
Collapse
|
32
|
Zandbergen MA, Reenalda J, van Middelaar RP, Ferla RI, Buurke JH, Veltink PH. Drift-Free 3D Orientation and Displacement Estimation for Quasi-Cyclical Movements Using One Inertial Measurement Unit: Application to Running. SENSORS 2022; 22:s22030956. [PMID: 35161701 PMCID: PMC8838725 DOI: 10.3390/s22030956] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/14/2022] [Accepted: 01/19/2022] [Indexed: 12/04/2022]
Abstract
A Drift-Free 3D Orientation and Displacement estimation method (DFOD) based on a single inertial measurement unit (IMU) is proposed and validated. Typically, body segment orientation and displacement methods rely on a constant- or zero-velocity point to correct for drift. Therefore, they are not easily applicable to more proximal segments than the foot. DFOD uses an alternative single sensor drift reduction strategy based on the quasi-cyclical nature of many human movements. DFOD assumes that the quasi-cyclical movement occurs in a quasi-2D plane and with an approximately constant cycle average velocity. DFOD is independent of a constant- or zero-velocity point, a biomechanical model, Kalman filtering or a magnetometer. DFOD reduces orientation drift by assuming a cyclical movement, and by defining a functional coordinate system with two functional axes. These axes are based on the mean acceleration and rotation axes over multiple complete gait cycles. Using this drift-free orientation estimate, the displacement of the sensor is computed by again assuming a cyclical movement. Drift in displacement is reduced by subtracting the mean value over five gait cycle from the free acceleration, velocity, and displacement. Estimated 3D sensor orientation and displacement for an IMU on the lower leg were validated with an optical motion capture system (OMCS) in four runners during constant velocity treadmill running. Root mean square errors for sensor orientation differences between DFOD and OMCS were 3.1 ± 0.4° (sagittal plane), 5.3 ± 1.1° (frontal plane), and 5.0 ± 2.1° (transversal plane). Sensor displacement differences had a root mean square error of 1.6 ± 0.2 cm (forward axis), 1.7 ± 0.6 cm (mediolateral axis), and 1.6 ± 0.2 cm (vertical axis). Hence, DFOD is a promising 3D drift-free orientation and displacement estimation method based on a single IMU in quasi-cyclical movements with many advantages over current methods.
Collapse
Affiliation(s)
- Marit A. Zandbergen
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands
- Correspondence:
| | - Jasper Reenalda
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands
| | - Robbert P. van Middelaar
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
| | - Romano I. Ferla
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
| | - Jaap H. Buurke
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands
| | - Peter H. Veltink
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands; (J.R.); (R.P.v.M.); (R.I.F.); (J.H.B.); (P.H.V.)
| |
Collapse
|
33
|
Effects of Minimalist Footwear and Foot Strike Pattern on Plantar Pressure during a Prolonged Running. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12010506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The use of minimalist shoes (MS) in running involves changes in running mechanics compared to conventional shoes (CS), but there is still little research analysing the effects of this footwear on plantar pressure, which could help to understand some risk injury factors. Moreover, there are no studies examining the effects of a prolonged running and foot strike patterns on baropodometric variables in MS. Therefore, the aim of this study was to analyse the changes produced using MS on plantar pressure during a prolonged running, as well as its interaction with the time and foot strike pattern. Twenty-one experienced minimalist runners (age 38 ± 10 years, MS running experience 2 ± 1 years) ran with MS and CS for 30 min at 80% of their maximal aerobic speed, and mean pressure, peak pressure, contact time, centre of pressure velocity, relative force and contact area were analysed using a pressure platform. Foot strike pattern and time were also considered as factors. The multivariable linear regression mixed models showed that the use of MS induced, at the end of a prolonged running, higher peak pressure (p = 0.008), lower contact time (p = 0.004) and lower contact area (p < 0.001) than using CS. Also, runners with forefoot strike pattern using MS, compared to midfoot and rearfoot patterns, showed higher mean and peak pressure (p < 0.001) and lower contact time and area (p < 0.05). These results should be considered when planning training for runners using MS, as higher peak pressure values when using this type of footwear could be a risk factor for the development of some foot injuries.
Collapse
|
34
|
Continuous Tracking of Foot Strike Pattern during a Maximal 800-Meter Run. SENSORS 2021; 21:s21175782. [PMID: 34502672 PMCID: PMC8434103 DOI: 10.3390/s21175782] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 08/24/2021] [Accepted: 08/25/2021] [Indexed: 01/31/2023]
Abstract
(1) Background: Research into foot strike patterns (FSP) has increased due to its potential influence on performance and injury reduction. The purpose of this study was to evaluate changes in FSP throughout a maximal 800-m run using a conformable inertial measurement unit attached to the foot; (2) Methods: Twenty-one subjects (14 female, 7 male; 23.86 ± 4.25 y) completed a maximal 800-m run while foot strike characteristics were continually assessed. Two measures were assessed across 100-m intervals: the percentage of rearfoot strikes (FSP%RF), and foot strike angle (FSA). The level of significance was set to p ≤ 0.05; (3) Results: There were no differences in FSP%RF throughout the run. Significant differences were seen between curve and straight intervals for FSAAVE (F [1, 20] = 18.663, p < 0.001, ηp2 = 0.483); (4) Conclusions: Participants displayed decreased FSA, likely indicating increased plantarflexion, on the curve compared to straight intervals. The analyses of continuous variables, such as FSA, allow for the detection of subtle changes in foot strike characteristics, which is not possible with discrete classifiers, such as FSP%RF.
Collapse
|
35
|
Eitzen I, Renberg J, Færevik H. The Use of Wearable Sensor Technology to Detect Shock Impacts in Sports and Occupational Settings: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:4962. [PMID: 34372198 PMCID: PMC8348544 DOI: 10.3390/s21154962] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 07/16/2021] [Accepted: 07/17/2021] [Indexed: 12/03/2022]
Abstract
Shock impacts during activity may cause damage to the joints, muscles, bones, or inner organs. To define thresholds for tolerable impacts, there is a need for methods that can accurately monitor shock impacts in real-life settings. Therefore, the main aim of this scoping review was to present an overview of existing methods for assessments of shock impacts using wearable sensor technology within two domains: sports and occupational settings. Online databases were used to identify papers published in 2010-2020, from which we selected 34 papers that used wearable sensor technology to measure shock impacts. No studies were found on occupational settings. For the sports domain, accelerometry was the dominant type of wearable sensor technology utilized, interpreting peak acceleration as a proxy for impact. Of the included studies, 28 assessed foot strike in running, head impacts in invasion and team sports, or different forms of jump landings or plyometric movements. The included studies revealed a lack of consensus regarding sensor placement and interpretation of the results. Furthermore, the identified high proportion of validation studies support previous concerns that wearable sensors at present are inadequate as a stand-alone method for valid and accurate data on shock impacts in the field.
Collapse
Affiliation(s)
- Ingrid Eitzen
- Department of Smart Sensor Systems, SINTEF Digital, 0373 Oslo, Norway
| | - Julie Renberg
- Department of Health Research, SINTEF Digital, 7034 Trondheim, Norway
| | - Hilde Færevik
- Department of Health Research, SINTEF Digital, 7034 Trondheim, Norway
| |
Collapse
|
36
|
Modification of Angular Kinematics and Spatiotemporal Parameters during Running after Central and Peripheral Fatigue. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11146610] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Fatigue causes kinematics modifications during running, and it could be related to injuries. The aim was to identify and compare the effects of central and peripheral fatigue on angular kinematics and spatiotemporal parameters during running. Angular kinematics and spatiotemporal parameters were evaluated using an infrared motion capture system and were registered during 2 min treadmill running in pre- and post-fatigue states in eighteen male recreational runners. Central fatigue was induced by a 30 min running fatigue protocol on a treadmill, while peripheral fatigue in quadriceps and hamstrings muscles was induced by an isokinetic dynamometer fatigue protocol. Central fatigue increased the anterior shank oscillation during the initial contact, knee flexion during the maximum absorption, posterior shank oscillation during propulsion, and stance time (p < 0.05). Peripheral fatigue decreased ankle dorsiflexion during initial contact and increased knee flexion and posterior shank oscillation during propulsion (p < 0.05). Moreover, central fatigue increased to a greater extent the hip and knee flexion and ankle dorsiflexion during initial contact and maximum absorption as well as stance time and propulsion time (p < 0.05). These results suggested that central fatigue causes greater increases in the range of movements during the midstance than peripheral fatigue.
Collapse
|
37
|
Chen TLW, Lam WK, Wong DWC, Zhang M. A half marathon shifts the mediolateral force distribution at the tibiofemoral joint. Eur J Sport Sci 2021; 22:1017-1024. [PMID: 34077303 DOI: 10.1080/17461391.2021.1938690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Runners' gait patterns vary during a half marathon and influence the knee joint mechanics. Joint contact force is a better estimate of the net joint loadings than external joint moments and closely correlates to injury risks. This study explored the changes of lower limb joint kinematics, muscle activities, and knee joint loading in runners across the running mileages of a half marathon. Fourteen runners completed a half marathon on an instrumented treadmill where motion capture was conducted every 2 km (from 2 to 20 km). A musculoskeletal model incorporating medial/lateral tibiofemoral compartments was used to process the movement data and report outcome variables at the selected distance checkpoints. Statistics showed no changes in joint angles, muscle co-contraction index, ground reaction force variables, and medial tibiofemoral contact force (p > 0.05). Knee adduction moment at 18 km was significantly lower than those at 2 km (p = 0.002, γ = 0.813) and 6 km (p = 0.001, γ = 0.663). Compared to that at 2 km, lateral tibiofemoral contact force was reduced at 18 km (p = 0.030, Hedges' g = 0.690), 16 km (p < 0.001, Hedges' g = 0.782), 14 km (p = 0.045, Hedges' g = 0.859), and 10 km (p < 0.001, Hedges' g = 0.771) respectively. Mechanical realignment of the lower limb may be the cause of the altered knee loadings and possibly led to reduced running economy in response to a prolonged run. The injury potential of the redistributed tibiofemoral forces warranted further studies.
Collapse
Affiliation(s)
- Tony Lin-Wei Chen
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, People's Republic of China.,Li Ning Sports Technology (Shenzhen) Co. Ltd., Shenzhen, People's Republic of China
| | - Wing-Kai Lam
- Li Ning Sports Technology (Shenzhen) Co. Ltd., Shenzhen, People's Republic of China.,Li Ning Sports Science Research Center, Li Ning (China) Sports Goods Co. Ltd., Beijing, People's Republic of China.,Department of Kinesiology, Shenyang Sports Institute, Shenyang, People's Republic of China
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, People's Republic of China.,Department of Kinesiology, Shenyang Sports Institute, Shenyang, People's Republic of China
| | - Ming Zhang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, People's Republic of China.,Department of Kinesiology, Shenyang Sports Institute, Shenyang, People's Republic of China
| |
Collapse
|
38
|
Increases in Load Carriage Magnitude and Forced Marching Change Lower-Extremity Coordination in Physically Active, Recruit-Aged Women. J Appl Biomech 2021; 37:343-350. [PMID: 34051696 DOI: 10.1123/jab.2020-0340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 04/01/2021] [Accepted: 04/08/2021] [Indexed: 11/18/2022]
Abstract
The objective was to examine the interactive effects of load magnitude and locomotion pattern on lower-extremity joint angles and intralimb coordination in recruit-aged women. Twelve women walked, ran, and forced marched at body weight and with loads of +25%, and +45% of body weight on an instrumented treadmill with infrared cameras. Joint angles were assessed in the sagittal plane. Intralimb coordination of the thigh-shank and shank-foot couple was assessed with continuous relative phase. Mean absolute relative phase (entire stride) and deviation phase (stance phase) were calculated from continuous relative phase. At heel strike, forced marching exhibited greater (P < .001) hip flexion, knee extension, and ankle plantar flexion compared with running. At mid-stance, knee flexion (P = .007) and ankle dorsiflexion (P = .04) increased with increased load magnitude for all locomotion patterns. Forced marching (P = .009) demonstrated a "stiff-legged" locomotion pattern compared with running, evidenced by the more in-phase mean absolute relative phase values. Running (P = .03) and walking (P = .003) had greater deviation phase than forced marching. Deviation phase increased for running (P = .03) and walking (P < .001) with increased load magnitude but not for forced marching. With loads of >25% of body weight, forced marching may increase risk of injury due to inhibited energy attenuation up the kinetic chain and lack of variability to disperse force across different supportive structures.
Collapse
|
39
|
Marotta L, Buurke JH, van Beijnum BJF, Reenalda J. Towards Machine Learning-Based Detection of Running-Induced Fatigue in Real-World Scenarios: Evaluation of IMU Sensor Configurations to Reduce Intrusiveness. SENSORS 2021; 21:s21103451. [PMID: 34063478 PMCID: PMC8156769 DOI: 10.3390/s21103451] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/11/2021] [Accepted: 05/13/2021] [Indexed: 12/14/2022]
Abstract
Physical fatigue is a recurrent problem in running that negatively affects performance and leads to an increased risk of being injured. Identification and management of fatigue helps reducing such negative effects, but is presently commonly based on subjective fatigue measurements. Inertial sensors can record movement data continuously, allowing recording for long durations and extensive amounts of data. Here we aimed to assess if inertial measurement units (IMUs) can be used to distinguish between fatigue levels during an outdoor run with a machine learning classification algorithm trained on IMU-derived biomechanical features, and what is the optimal configuration to do so. Eight runners ran 13 laps of 400 m on an athletic track at a constant speed with 8 IMUs attached to their body (feet, tibias, thighs, pelvis, and sternum). Three segments were extracted from the run: laps 2–4 (no fatigue condition, Rating of Perceived Exertion (RPE) = 6.0 ± 0.0); laps 8–10 (mild fatigue condition, RPE = 11.7 ± 2.0); laps 11–13 (heavy fatigue condition, RPE = 14.2 ± 3.0), run directly after a fatiguing protocol (progressive increase of speed until RPE ≥ 16) that followed lap 10. A random forest classification algorithm was trained with selected features from the 400 m moving average of the IMU-derived accelerations, angular velocities, and joint angles. A leave-one-subject-out cross validation was performed to assess the optimal combination of IMU locations to detect fatigue and selected sensor configurations were considered. The left tibia was the most recurrent sensor location, resulting in accuracies ranging between 0.761 (single left tibia location) and 0.905 (all IMU locations). These findings contribute toward a balanced choice between higher accuracy and lower intrusiveness in the development of IMU-based fatigue detection devices in running.
Collapse
Affiliation(s)
- Luca Marotta
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (J.H.B.); (J.R.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands;
- Correspondence:
| | - Jaap H. Buurke
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (J.H.B.); (J.R.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands;
| | - Bert-Jan F. van Beijnum
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands;
| | - Jasper Reenalda
- Roessingh Research and Development, 7522 AH Enschede, The Netherlands; (J.H.B.); (J.R.)
- Department of Biomedical Signals and Systems, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, 7522 NB Enschede, The Netherlands;
| |
Collapse
|
40
|
Napier C, BSc MR, Menon C, Paquette MR. Session Rating of Perceived Exertion Combined With Training Volume for Estimating Training Responses in Runners. J Athl Train 2021; 55:1285-1291. [PMID: 33064812 DOI: 10.4085/1062-6050-573-19] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
CONTEXT Historically, methods of monitoring training loads in runners have used simple and convenient metrics, including the duration or distance run. Changes in these values are assessed on a week-to-week basis to induce training adaptations and manage injury risk. To date, whether different measures of external loads, including biomechanical measures, provide better information regarding week-to-week changes in external loads experienced by a runner is unclear. In addition, the importance of combining internal-load measures, such as session rating of perceived exertion (sRPE), with different external-load measures to monitor week-to-week changes in training load in runners is unknown. OBJECTIVE To compare week-to-week changes in the training loads of recreational runners using different quantification methods. DESIGN Case series. SETTING Community based. PATIENTS OR OTHER PARTICIPANTS Recreational runners in Vancouver, British Columbia. MAIN OUTCOME MEASURE(S) Week-to-week changes in running time, steps, and cumulative shock, in addition to the product of each of these variables and the corresponding sRPE scores for each run. RESULTS Sixty-eight participants were included in the final analysis. Differences were present in week-to-week changes for running time compared with timeRPE (d = 0.24), stepsRPE (d = 0.24), and shockRPE (d = 0.31). The differences between week-to-week changes in running time and cumulative shock were also significant at the overall group level (d = 0.10). CONCLUSIONS We found that the use of an internal training-load measure (sRPE) in combination with external load (training duration) provided a more individualized estimate of week-to-week changes in overall training stress. A better estimation of training stress has significant implications for monitoring training adaptations, resulting performance, and possibly injury risk reduction. We therefore recommend the regular use of sRPE and training duration to monitor training load in runners. The use of cumulative shock as a measure of external load in some runners may also be more valid than duration alone.
Collapse
Affiliation(s)
- Christopher Napier
- Menrva Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Faculty of Applied Science, Simon Fraser University, Metro Vancouver, BC, Canada.,Department of Physical Therapy, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada
| | | | - Carlo Menon
- Menrva Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Faculty of Applied Science, Simon Fraser University, Metro Vancouver, BC, Canada
| | | |
Collapse
|
41
|
Reenalda J, Zandbergen MA, Harbers JHD, Paquette MR, Milner CE. Detection of foot contact in treadmill running with inertial and optical measurement systems. J Biomech 2021; 121:110419. [PMID: 33873111 DOI: 10.1016/j.jbiomech.2021.110419] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 03/02/2021] [Accepted: 03/23/2021] [Indexed: 11/19/2022]
Abstract
In running assessments, biomechanics of the stance phase are often measured to understand external loads applied to the body. Identifying time of initial foot contact can be challenging in runners with different strike patterns. Peak downward velocity of the pelvis (PDVP) has been validated in a laboratory setting to detect initial contact. Inertial measurement units (IMUs) allow measurements of kinematic variables outside laboratory settings. The aim of this study was to validate the PDVP method using an inertial and optical motion capture system to detect initial contact at different speeds and foot strike patterns compared to the force sensing criterion. Twenty healthy runners ran for two minutes at 11, 13, and 15 km/h on a force-instrumented treadmill. 3D kinematics were obtained from an optical motion capture system and an 8-sensor inertial system. A generalized estimating equation showed no effect of footstrike pattern on the time difference (offset) between initial contact based on an inertial or optical system and the force sensing criterion. There was a significant main effect of speed on offset, in which offsets decreased with higher speeds. There was no interaction effect of speed and foot strike pattern on the offsets. Offsets ranged from 21.7 ± 0.2 ms for subjects running at 15 km/h (inertial versus force sensing criterion) to 27.2 ± 0.1 ms for subjects running at 11 km/h (optical versus force sensing criterion). These findings support the validity of the PDVP method obtained from optical and inertial systems to detect initial contact in different footstrike patterns and at different running speeds.
Collapse
Affiliation(s)
- Jasper Reenalda
- University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Enschede, The Netherlands; Roessingh Research and Development, Enschede, The Netherlands.
| | - Marit A Zandbergen
- Roessingh Research and Development, Enschede, The Netherlands; University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Enschede, The Netherlands
| | - Jelle H D Harbers
- University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Enschede, The Netherlands; Roessingh Research and Development, Enschede, The Netherlands
| | - Max R Paquette
- School of Health Studies, University of Memphis, Memphis, TN, United States
| | - Clare E Milner
- Department of Physical Therapy & Rehabilitation Sciences, Drexel University, Philadelphia, PA, United States
| |
Collapse
|
42
|
Van den Berghe P, Lorenzoni V, Derie R, Six J, Gerlo J, Leman M, De Clercq D. Music-based biofeedback to reduce tibial shock in over-ground running: a proof-of-concept study. Sci Rep 2021; 11:4091. [PMID: 33603028 PMCID: PMC7892879 DOI: 10.1038/s41598-021-83538-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 01/24/2021] [Indexed: 12/22/2022] Open
Abstract
Methods to reduce impact in distance runners have been proposed based on real-time auditory feedback of tibial acceleration. These methods were developed using treadmill running. In this study, we extend these methods to a more natural environment with a proof-of-concept. We selected ten runners with high tibial shock. They used a music-based biofeedback system with headphones in a running session on an athletic track. The feedback consisted of music superimposed with noise coupled to tibial shock. The music was automatically synchronized to the running cadence. The level of noise could be reduced by reducing the momentary level of tibial shock, thereby providing a more pleasant listening experience. The running speed was controlled between the condition without biofeedback and the condition of biofeedback. The results show that tibial shock decreased by 27% or 2.96 g without guided instructions on gait modification in the biofeedback condition. The reduction in tibial shock did not result in a clear increase in the running cadence. The results indicate that a wearable biofeedback system aids in shock reduction during over-ground running. This paves the way to evaluate and retrain runners in over-ground running programs that target running with less impact through instantaneous auditory feedback on tibial shock.
Collapse
Affiliation(s)
- Pieter Van den Berghe
- Biomechanics and Motor Control of Human Movement, Department of Movement and Sports Sciences, Ghent University, 9000, Ghent, Belgium.
| | - Valerio Lorenzoni
- Department of Arts, Music and Theatre Sciences, IPEM, Ghent University, 9000, Ghent, Belgium
| | - Rud Derie
- Biomechanics and Motor Control of Human Movement, Department of Movement and Sports Sciences, Ghent University, 9000, Ghent, Belgium
| | - Joren Six
- Department of Arts, Music and Theatre Sciences, IPEM, Ghent University, 9000, Ghent, Belgium
| | - Joeri Gerlo
- Biomechanics and Motor Control of Human Movement, Department of Movement and Sports Sciences, Ghent University, 9000, Ghent, Belgium
| | - Marc Leman
- Department of Arts, Music and Theatre Sciences, IPEM, Ghent University, 9000, Ghent, Belgium
| | - Dirk De Clercq
- Biomechanics and Motor Control of Human Movement, Department of Movement and Sports Sciences, Ghent University, 9000, Ghent, Belgium
| |
Collapse
|
43
|
Giraldo-Pedroza A, Lee WCC, Lam WK, Coman R, Alici G. Effects of Wearable Devices with Biofeedback on Biomechanical Performance of Running-A Systematic Review. SENSORS 2020; 20:s20226637. [PMID: 33228137 PMCID: PMC7699362 DOI: 10.3390/s20226637] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/09/2020] [Accepted: 11/18/2020] [Indexed: 01/30/2023]
Abstract
This present review includes a systematic search for peer-reviewed articles published between March 2009 and March 2020 that evaluated the effects of wearable devices with biofeedback on the biomechanics of running. The included articles did not focus on physiological and metabolic metrics. Articles with patients, animals, orthoses, exoskeletons and virtual reality were not included. Following the PRISMA guidelines, 417 articles were first identified, and nineteen were selected following the removal of duplicates and articles which did not meet the inclusion criteria. Most reviewed articles reported a significant reduction in positive peak acceleration, which was found to be related to tibial stress fractures in running. Some previous studies provided biofeedback aiming to increase stride frequencies. They produced some positive effects on running, as they reduced vertical load in knee and ankle joints and vertical displacement of the body and increased knee flexion. Some other parameters, including contact ground time and speed, were fed back by wearable devices for running. Such devices reduced running time and increased swing phase time. This article reviews challenges in this area and suggests future studies can evaluate the long-term effects in running biomechanics produced by wearable devices with biofeedback.
Collapse
Affiliation(s)
- Alexandra Giraldo-Pedroza
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia; (A.G.-P.); (G.A.)
- Applied Mechatronics and Biomedical Engineering Research (AMBER) Group, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Winson Chiu-Chun Lee
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia; (A.G.-P.); (G.A.)
- Applied Mechatronics and Biomedical Engineering Research (AMBER) Group, University of Wollongong, Wollongong, NSW 2522, Australia
- Correspondence: (W.C.-C.L.); (W.-K.L.)
| | - Wing-Kai Lam
- Department of Kinesiology, Shenyang Sport University, Shenyang 110102, China
- Li Ning Sports Science Research Center, Beijing 101111, China
- Correspondence: (W.C.-C.L.); (W.-K.L.)
| | - Robyn Coman
- School of Health and Society, Faculty of Arts, Social Sciences & Humanities, University of Wollongong, Wollongong, NSW 2522, Australia;
| | - Gursel Alici
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522, Australia; (A.G.-P.); (G.A.)
- Applied Mechatronics and Biomedical Engineering Research (AMBER) Group, University of Wollongong, Wollongong, NSW 2522, Australia
- ARC Centre of Excellence for Electromaterials Science, University of Wollongong Innovation Campus, North Wollongong, NSW 2500, Australia
| |
Collapse
|
44
|
The Effect of Fatigue on Leg Muscle Activation and Tibial Acceleration During a Jumping Task. J Sport Rehabil 2020; 29:1093-1099. [PMID: 31810058 DOI: 10.1123/jsr.2018-0495] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 08/29/2019] [Accepted: 10/15/2019] [Indexed: 11/18/2022]
Abstract
CONTEXT Lower-extremity stress fractures (SFx) are a common occurrence during load-bearing activities of jumping and landing. To detect biomechanical changes during jumping postinjury, a fatigue model could be used. OBJECTIVE To evaluate muscle activation in the lower leg and tibial accelerations (TAs) prefatigue to postfatigue following a jumping task in those with and without a history of SFx. DESIGN Repeated-measures. SETTING Athletic Training Research Lab. PARTICIPANTS A total of 30 active college-aged students with and without a history of lower-extremity (leg or foot) SFx (15 males and 15 females; 21.5 [5.04] y, height = 173.5 [12.7] cm, weight = 72.65 [16.4] kg). INTERVENTION A maximal vertical jump on one leg 3 times with arms folded across the chest prefatigue to postfatigue was performed. Fatigue protocol was standing heel raises on a custom-built platform at a pace controlled by a metronome until task failure was reached. Legs were tested using a randomized testing order. Electromyographic (EMG) surface electrodes were placed on the medial gastrocnemius, soleus, and tibialis anterior following a standardized placement protocol. A triaxial accelerometer was attached to the proximal anteromedial surface of the tibia. MAIN OUTCOME MEASURES Linear envelopes of the medial gastrocnemius, soleus, and tibialis anterior and peak accelerations (resultant acceleration takeoff and landing). RESULTS Significant interaction for leg × test for tibialis anterior with a posttest difference between SFx and control (P = .05). There were decreases in EMG linear envelope following fatigue for medial gastrocnemius (P < .01) and tibialis anterior (P = .12) pretest to posttest. At takeoff, TA was greater in the SFx contralateral leg in comparison with the control leg (P = .04). At landing, TA was greater in posttest (P < .01) and in the SFx leg compared with SFx contralateral (P = .14). CONCLUSION A decrease in muscle activity and an increase in TA following fatigue were noted for all subjects but especially for those with a history of SFx.
Collapse
|
45
|
Sensor-to-Segment Calibration Methodologies for Lower-Body Kinematic Analysis with Inertial Sensors: A Systematic Review. SENSORS 2020; 20:s20113322. [PMID: 32545227 PMCID: PMC7309059 DOI: 10.3390/s20113322] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/01/2020] [Accepted: 06/08/2020] [Indexed: 11/20/2022]
Abstract
Kinematic analysis is indispensable to understanding and characterizing human locomotion. Thanks to the development of inertial sensors based on microelectronics systems, human kinematic analysis in an ecological environment is made possible. An important issue in human kinematic analyses with inertial sensors is the necessity of defining the orientation of the inertial sensor coordinate system relative to its underlying segment coordinate system, which is referred to sensor-to-segment calibration. Over the last decade, we have seen an increase of proposals for this purpose. The aim of this review is to highlight the different proposals made for lower-body segments. Three different databases were screened: PubMed, Science Direct and IEEE Xplore. One reviewer performed the selection of the different studies and data extraction. Fifty-five studies were included. Four different types of calibration method could be identified in the articles: the manual, static, functional, and anatomical methods. The mathematical approach to obtain the segment axis and the calibration evaluation were extracted from the selected articles. Given the number of propositions and the diversity of references used to evaluate the methods, it is difficult today to form a conclusion about the most suitable. To conclude, comparative studies are required to validate calibration methods in different circumstances.
Collapse
|
46
|
Held JPO, Yu K, Pyles C, Veerbeek JM, Bork F, Heining SM, Navab N, Luft AR. Augmented Reality-Based Rehabilitation of Gait Impairments: Case Report. JMIR Mhealth Uhealth 2020; 8:e17804. [PMID: 32452815 PMCID: PMC7284394 DOI: 10.2196/17804] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 03/06/2020] [Accepted: 03/22/2020] [Indexed: 11/27/2022] Open
Abstract
Background Gait and balance impairments are common in neurological diseases, including stroke, and negatively affect patients’ quality of life. Improving balance and gait are among the main goals of rehabilitation. Rehabilitation is mainly performed in clinics, which lack context specificity; therefore, training in the patient’s home environment is preferable. In the last decade, developed rehabilitation technologies such as virtual reality and augmented reality (AR) have enabled gait and balance training outside clinics. Here, we propose a new method for gait rehabilitation in persons who have had a stroke in which mobile AR technology and a sensor-based motion capture system are combined to provide fine-grained feedback on gait performance in real time. Objective The aims of this study were (1) to investigate manipulation of the gait pattern of persons who have had a stroke based on virtual augmentation during overground walking compared to walking without AR performance feedback and (2) to investigate the usability of the AR system. Methods We developed the ARISE (Augmented Reality for gait Impairments after StrokE) system, in which we combined a development version of HoloLens 2 smart glasses (Microsoft Corporation) with a sensor-based motion capture system. One patient with chronic minor gait impairment poststroke completed clinical gait assessments and an AR parkour course with patient-centered performance gait feedback. The movement kinematics during gait as well as the usability and safety of the system were evaluated. Results The patient changed his gait pattern during AR parkour compared to the pattern observed during the clinical gait assessments. He recognized the virtual objects and ranked the usability of the ARISE system as excellent. In addition, the patient stated that the system would complement his standard gait therapy. Except for the symptom of exhilaration, no adverse events occurred. Conclusions This project provided the first evidence of gait adaptation during overground walking based on real-time feedback through visual and auditory augmentation. The system has potential to provide gait and balance rehabilitation outside the clinic. This initial investigation of AR rehabilitation may aid the development and investigation of new gait and balance therapies.
Collapse
Affiliation(s)
- Jeremia Philipp Oskar Held
- Division of Vascular Neurology and Neurorehabilitation, Department of Neurology, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Kevin Yu
- University Hospital Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Connor Pyles
- Johns Hopkins Applied Physics Laboratory, Johns Hopkins University, Laurel, MD, United States
| | - Janne Marieke Veerbeek
- Division of Vascular Neurology and Neurorehabilitation, Department of Neurology, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Felix Bork
- Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Munich, Germany
| | - Sandro-Michael Heining
- Department of Trauma Surgery, University of Zurich and University Hospital Zurich, Zurich, Switzerland
| | - Nassir Navab
- Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Munich, Germany.,Computer Aided Medical Procedures, Johns Hopkins University, Baltimore, MD, United States
| | - Andreas Rüdiger Luft
- Division of Vascular Neurology and Neurorehabilitation, Department of Neurology, University of Zurich and University Hospital Zurich, Zurich, Switzerland.,cereneo Center for Neurology and Rehabilitation, Vitznau, Switzerland
| |
Collapse
|
47
|
Schütz U, Ehrhardt M, Göd S, Billich C, Beer M, Trattnig S. A mobile MRI field study of the biochemical cartilage reaction of the knee joint during a 4,486 km transcontinental multistage ultra-marathon using T2* mapping. Sci Rep 2020; 10:8157. [PMID: 32424133 PMCID: PMC7235258 DOI: 10.1038/s41598-020-64994-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Accepted: 04/21/2020] [Indexed: 02/08/2023] Open
Abstract
Nearly nothing is known about the consequences of ultra-long-distance running on knee cartilage. In this mobile MRI field study, we analysed the biochemical effects of a 4,486 km transcontinental multistage ultra-marathon on femorotibial joint (FTJ) cartilage. Serial MRI data were acquired from 22 subjects (20 male, 18 finisher) using a 1.5 T MR scanner mounted on a 38-ton trailer, travelling with the participants of the TransEurope FootRace (TEFR) day by day over 64 stages. The statistical analyses focused on intrachondral T2* behaviour during the course of the TEFR as the main outcome variable of interest. T2* mapping (sagittal FLASH T2* weighted gradient echo) is a validated and highly accurate method for quantitative compositional cartilage analysis of specific weightbearing areas of the FTJ. T2* mapping is sensitive to changes in the equilibrium of free intrachondral water, which depends on the content and orientation of collagen and the proteoglycan content in the extracellular cartilage matrix. Within the first 1,100 km, a significant running load-induced T2* increase occurred in all joint regions: 44.0% femoral-lateral, 42.9% tibial-lateral, 34.9% femoral-medial, and 25.1% tibial-medial. Osteochondral lesions showed no relevant changes or new occurrence during the TEFR. The reasons for stopping the race were not associated with knee problems. As no further T2* elevation was found in the second half of the TEFR but a decreasing T2* trend (recovery) was observed after the 3,500 km run, we assume that no further softening of the cartilage occurs with ongoing running burden over ultra-long distances extending 4,500 km. Instead, we assume the ability of the FTJ cartilage matrix to reorganize and adapt to the load.
Collapse
Affiliation(s)
- Uwe Schütz
- Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Albert-Einstein-Allee 23, D-89081, Ulm, Germany.
| | - Martin Ehrhardt
- Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Albert-Einstein-Allee 23, D-89081, Ulm, Germany
| | - Sabine Göd
- MR Centre of Excellence- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, BT32, Lazarettgasse 14, 1090, Vienna, Austria
| | - Christian Billich
- Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Albert-Einstein-Allee 23, D-89081, Ulm, Germany
| | - Meinrad Beer
- Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Albert-Einstein-Allee 23, D-89081, Ulm, Germany
| | - Siegfried Trattnig
- MR Centre of Excellence- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, BT32, Lazarettgasse 14, 1090, Vienna, Austria
| |
Collapse
|
48
|
Weygers I, Kok M, Konings M, Hallez H, De Vroey H, Claeys K. Inertial Sensor-Based Lower Limb Joint Kinematics: A Methodological Systematic Review. SENSORS 2020; 20:s20030673. [PMID: 31991862 PMCID: PMC7038336 DOI: 10.3390/s20030673] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Revised: 01/16/2020] [Accepted: 01/23/2020] [Indexed: 11/21/2022]
Abstract
The use of inertial measurement units (IMUs) has gained popularity for the estimation of lower limb kinematics. However, implementations in clinical practice are still lacking. The aim of this review is twofold—to evaluate the methodological requirements for IMU-based joint kinematic estimation to be applicable in a clinical setting, and to suggest future research directions. Studies within the PubMed, Web Of Science and EMBASE databases were screened for eligibility, based on the following inclusion criteria: (1) studies must include a methodological description of how kinematic variables were obtained for the lower limb, (2) kinematic data must have been acquired by means of IMUs, (3) studies must have validated the implemented method against a golden standard reference system. Information on study characteristics, signal processing characteristics and study results was assessed and discussed. This review shows that methods for lower limb joint kinematics are inherently application dependent. Sensor restrictions are generally compensated with biomechanically inspired assumptions and prior information. Awareness of the possible adaptations in the IMU-based kinematic estimates by incorporating such prior information and assumptions is necessary, before drawing clinical decisions. Future research should focus on alternative validation methods, subject-specific IMU-based biomechanical joint models and disturbed movement patterns in real-world settings.
Collapse
Affiliation(s)
- Ive Weygers
- KU Leuven Campus Bruges, Department of Rehabilitation Sciences, 8200 Bruges, Belgium; (M.K.); (H.D.V.); (K.C.)
- Correspondence: ; Tel.: +32-5066-4993
| | - Manon Kok
- TU Delft, Department of Mechanical and Materials Engineering, 2628 CD Delft, The Netherlands;
| | - Marco Konings
- KU Leuven Campus Bruges, Department of Rehabilitation Sciences, 8200 Bruges, Belgium; (M.K.); (H.D.V.); (K.C.)
| | - Hans Hallez
- KU Leuven Campus Bruges, Department of Computer Science, Mechatronics Research Group, 8200 Bruges, Belgium;
| | - Henri De Vroey
- KU Leuven Campus Bruges, Department of Rehabilitation Sciences, 8200 Bruges, Belgium; (M.K.); (H.D.V.); (K.C.)
| | - Kurt Claeys
- KU Leuven Campus Bruges, Department of Rehabilitation Sciences, 8200 Bruges, Belgium; (M.K.); (H.D.V.); (K.C.)
| |
Collapse
|
49
|
New Considerations for Wearable Technology Data: Changes in Running Biomechanics During a Marathon. J Appl Biomech 2019; 35:401–409. [PMID: 31629343 DOI: 10.1123/jab.2018-0453] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 05/24/2019] [Accepted: 07/29/2019] [Indexed: 11/18/2022]
Abstract
The purpose of this study was to use wearable technology data to quantify alterations in subject-specific running patterns throughout a marathon race and to determine if runners could be clustered into subgroups based on similar trends in running gait alterations throughout the marathon. Using a wearable sensor, data were collected for cadence, braking, bounce, pelvic rotation, pelvic drop, and ground contact time for 27 runners. A composite index was calculated based on the "typical" data (4-14 km) for each runner and evaluated for 14 individual 2-km sections thereafter to detect "atypical" data (ie, higher indices). A cluster analysis assigned all runners to a subgroup based on similar trends in running alterations. Results indicated that the indices became significantly higher starting at 20 to 22 km. Cluster 1 exhibited lower indices than cluster 2 throughout the marathon, and the only significant difference in characteristics between clusters was that cluster 1 had a lower age-grade performance score than cluster 2. In summary, this study presented a novel method to investigate the effects of fatigue on running biomechanics using wearable technology in a real-world setting. Recreational runners with higher age-grade performance scores had less atypical running patterns throughout the marathon compared with runners with lower age-grade performance scores.
Collapse
|
50
|
Greco-Otto P, Baggaley M, Edwards WB, Léguillette R. Water treadmill exercise reduces equine limb segmental accelerations and increases shock attenuation. BMC Vet Res 2019; 15:329. [PMID: 31519197 PMCID: PMC6743102 DOI: 10.1186/s12917-019-2075-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 09/03/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Equine water treadmills (WTs) are growing in popularity because they are believed to allow for high resistance, low impact exercise. However, little is known about the effect of water height on limb loading. The aim of this study was to evaluate the effect of water height and speed on segmental acceleration and impact attenuation during WT exercise in horses. Three uniaxial accelerometers (sampling rate: 2500 Hz) were secured on the left forelimb (hoof, mid-cannon, mid-radius). Horses walked at two speeds (S1: 0.83 m/s, S2: 1.39 m/s) and three water heights (mid-cannon, carpus, stifle), with a dry WT control. Peak acceleration of each segment was averaged over five strides, attenuation was calculated, and stride frequency was estimated by the time between successive hoof contacts. Linear mixed effects models were used to examine the effects of water height, speed, and accelerometer location on peak acceleration, attenuation and stride frequency (p < 0.05). RESULTS Peak acceleration at all locations was lower with water of any height compared to the dry control (p < 0.0001). Acceleration was reduced with water at the height of the stifle compared to mid-cannon water height (p = 0.02). Water at the height of the stifle attenuated more impact than water at the height of the cannon (p = 0.0001). CONCLUSIONS Water immersion during treadmill exercise reduced segmental accelerations and increased attenuation in horses. WT exercise may be beneficial in the rehabilitation of lower limb injuries in horses.
Collapse
Affiliation(s)
- Persephone Greco-Otto
- Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB T2N 4N1 Canada
| | - Michael Baggaley
- Human Performance Lab, Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 4N1 Canada
| | - W. B. Edwards
- Human Performance Lab, Faculty of Kinesiology, University of Calgary, Calgary, AB T2N 4N1 Canada
| | - Renaud Léguillette
- Department of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB T2N 4N1 Canada
| |
Collapse
|