1
|
Cameli M, Aboumarie HS, Pastore MC, Caliskan K, Cikes M, Garbi M, Lim HS, Muraru D, Mandoli GE, Pergola V, Plein S, Pontone G, Soliman OI, Maurovich-Horvat P, Donal E, Cosyns B, Petersen SE. Multimodality imaging for the evaluation and management of patients with long-term (durable) left ventricular assist devices. Eur Heart J Cardiovasc Imaging 2024; 25:e217-e240. [PMID: 38965039 DOI: 10.1093/ehjci/jeae165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 06/12/2024] [Indexed: 07/06/2024] Open
Abstract
Left ventricular assist devices (LVADs) are gaining increasing importance as therapeutic strategy in advanced heart failure (HF), not only as bridge to recovery or to transplant but also as destination therapy. Even though long-term LVADs are considered a precious resource to expand the treatment options and improve clinical outcome of these patients, these are limited by peri-operative and post-operative complications, such as device-related infections, haemocompatibility-related events, device mis-positioning, and right ventricular failure. For this reason, a precise pre-operative, peri-operative, and post-operative evaluation of these patients is crucial for the selection of LVAD candidates and the management LVAD recipients. The use of different imaging modalities offers important information to complete the study of patients with LVADs in each phase of their assessment, with peculiar advantages/disadvantages, ideal application, and reference parameters for each modality. This clinical consensus statement sought to guide the use of multimodality imaging for the evaluation of patients with advanced HF undergoing LVAD implantation.
Collapse
Affiliation(s)
- Matteo Cameli
- Department of Medical Biotechnologies, Division of Cardiology, University of Siena, Viale Bracci 16, 53100 Siena, Italy
| | - Hatem Soliman Aboumarie
- Department of Anaesthetics, Critical Care and Mechanical Circulatory Support, Harefield Hospital, Royal Brompton and Harefield Hospitals, London, UK
- School of Cardiovascular, Metabolic Sciences and Medicine, King's College, WC2R 2LS London, UK
| | - Maria Concetta Pastore
- Department of Medical Biotechnologies, Division of Cardiology, University of Siena, Viale Bracci 16, 53100 Siena, Italy
| | - Kadir Caliskan
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Maja Cikes
- Department of Cardiovascular Diseases, University Hospital Centre, Zagreb, Croatia
| | | | - Hoong Sern Lim
- Institute of Cardiovascular Sciences, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Denisa Muraru
- Department of Cardiology, Istituto Auxologico Italiano IRCCS, Milan, Italy
- Department of Medicine and Surgery, University Milano-Bicocca, Milan, Italy
| | - Giulia Elena Mandoli
- Department of Medical Biotechnologies, Division of Cardiology, University of Siena, Viale Bracci 16, 53100 Siena, Italy
| | - Valeria Pergola
- Department of Cardiology, Padua University Hospital, Padua 35128, Italy
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK
| | - Gianluca Pontone
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS, Milan, Italy
| | - Osama I Soliman
- Department of Cardiology, College of Medicine, Nursing and Health Sciences, National University of Galway, Galway, Ireland
| | | | - Erwan Donal
- University of Rennes, CHU Rennes, INSERM, LTSI-UMR 1099, Rennes F-35000, France
| | - Bernard Cosyns
- Centrum Voor Harten Vaatziekten (CHVZ), Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Brussels, Belgium
- In Vivo Cellular and Molecular Imaging (ICMI) Center, Vrije Universiteit Brussel (VUB), Brussels, Belgium
| | - Steffen E Petersen
- William Harvey Research Institute, National Institute for Health and Care Research Barts Biomedical Research Centre, Queen Mary University London, London, UK
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service Trust, London, UK
| |
Collapse
|
2
|
Lakhani HA, Lizarzaburo Penafiel LS, Fakhoury M, Seide M, Duran S PX, See JW, Dhillon DK, Shah S, Khan AM, Nimmagadda M, Susmitha T, Rai M. Heart Transplantation and Left Ventricular Assist Devices: Long-Term Prognosis and Effects on Mental Health. Cureus 2024; 16:e68691. [PMID: 39371854 PMCID: PMC11452842 DOI: 10.7759/cureus.68691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/04/2024] [Indexed: 10/08/2024] Open
Abstract
Heart transplantation and left ventricular assist devices (LVADs) have emerged as crucial interventions for end-stage heart failure, dramatically improving patient outcomes. This narrative review examines their historical context, indications, procedures, and outcomes, as well as their impact on long-term survival, quality of life, functional status, and mental health. While heart transplantation remains the optimal treatment, donor scarcity limits its application. LVADs have become a viable alternative, either as a bridge to transplantation or as destination therapy. Both interventions demonstrate similar long-term survival rates and significant improvements in health-related quality of life and functional status. However, they present distinct long-term management challenges, including immunosuppression needs for transplant recipients and device-related issues for LVAD patients. Mental health effects are considerable, necessitating psychological support and adaptive coping strategies. Complications such as infection, bleeding, and thrombosis remain concerns for both interventions. Patient selection criteria, technological advancements, and long-term management strategies are critical factors in optimizing outcomes. Future research should focus on device miniaturization, enhanced biocompatibility, and less invasive insertion techniques to further advance these therapies and improve patient care in end-stage heart failure.
Collapse
Affiliation(s)
| | | | - Marc Fakhoury
- Cardiology, Saint Joseph University of Beirut, Beirut, LBN
| | - Melinda Seide
- Internal Medicine, St. George's University School of Medicine, St. George's, GRD
| | | | - Jia Whei See
- Internal Medicine, Universitas Sriwijaya, Kota Palembang, IDN
| | | | - Shivendra Shah
- Internal Medicine, Nepalgunj Medical College, Nepalgunj, NPL
| | | | | | | | - Manju Rai
- Biotechnology, Shri Venkateshwara University, Gajraula, IND
| |
Collapse
|
3
|
Choi JJ, Bhasin S, Levstik J, Walsh P, Oldham MA, Lee HB. Association between psychosocial factors and left ventricular assist device implant outcomes: A systematic review. Gen Hosp Psychiatry 2024; 90:132-140. [PMID: 39180882 PMCID: PMC11484476 DOI: 10.1016/j.genhosppsych.2024.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 08/15/2024] [Accepted: 08/16/2024] [Indexed: 08/27/2024]
Abstract
BACKGROUND Psychosocial assessment is a core component of the multidisciplinary evaluation for left ventricular assist device (LVAD) implantation. The degree to which psychosocial conditions are considered a contraindication to LVAD implantation continues to be debated. This systematic review examines modifiable psychosocial factors as predictors of outcomes in patients undergoing LVAD implantation. METHODS We conducted a systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. The search resulted in 2509 articles. After deduplication, abstract and full-text review, 20 relevant articles were identified. RESULTS Included studies evaluated socioeconomic status (n = 6), caregiver characteristics (n = 6), non-adherence (n = 6), substance use (n = 13), and psychiatric disorder (n = 8). The most commonly measured outcomes were all-cause death, readmission rate, and adverse events. Studies varied widely in definition of each psychosocial factor and selected outcomes. No psychosocial factor was consistently associated with a specific outcome in all studies. Socioeconomic status was generally not associated with outcomes. Non-adherence, psychiatric disorder, and substance use were associated with higher risks of mortality, adverse events, and/or readmission. Findings on caregiver characteristics were mixed. CONCLUSION Of the psychosocial factors studied, non-adherence, psychiatric disorder, and substance use were the most consistently associated with an increased risk of mortality, readmission, and/or adverse events. Heterogeneity in research methodology and study quality across studies precludes firm conclusions regarding the impact of psychosocial factors on long-term patient outcomes. The results of this review reveal a need for adequately powered studies that use uniform definitions of psychosocial factors to clarify relationships between these factors and outcomes after LVAD implantation.
Collapse
Affiliation(s)
- Joy J Choi
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA.
| | - Shreya Bhasin
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA
| | - Johannes Levstik
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA
| | - Patrick Walsh
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA
| | - Mark A Oldham
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA
| | - Hochang Benjamin Lee
- Department of Psychiatry, University of Rochester Medical Center, Rochester, NY, USA
| |
Collapse
|
4
|
Beese S, Avşar TS, Price M, Quinn D, Lim HS, Dretzke J, Ogwulu CO, Barton P, Jackson L, Moore D. Clinical and cost-effectiveness of left ventricular assist devices as destination therapy for advanced heart failure: systematic review and economic evaluation. Health Technol Assess 2024; 28:1-237. [PMID: 39189844 PMCID: PMC11367304 DOI: 10.3310/mlfa4009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/28/2024] Open
Abstract
Background Selected patients with advanced heart failure ineligible for heart transplantation could benefit from left ventricular assist device therapy as 'destination therapy'. There is evidence of the efficacy of destination therapy; however, it is not currently commissioned within the United Kingdom National Health Service due to the lack of economic evidence. Objective What is the clinical and cost-effectiveness of a left ventricular assist device compared to medical management for patients with advanced heart failure ineligible for heart transplantation (destination therapy)? Methods A systematic review of evidence on the clinical and cost-effectiveness of left ventricular assist devices as destination therapy was undertaken including, where feasible, a network meta-analysis to provide an indirect estimate of the relative effectiveness of currently available left ventricular assist devices compared to medical management. For the systematic reviews, data sources searched (up to 11 January 2022) were Cochrane CENTRAL, MEDLINE and EMBASE via Ovid for primary studies, and Epistemonikos and Cochrane Database of Systematic Reviews for relevant systematic reviews. Trial registers were also searched, along with data and reports from intervention-specific registries. Economic studies were identified in EconLit, CEA registry and the NHS Economic Evaluation Database (NHS EED). The searches were supplemented by checking reference lists of included studies. An economic model (Markov) was developed to estimate the cost-effectiveness of left ventricular assist devices compared to medical management from the United Kingdom National Health Service/personal social service perspective. Deterministic and probabilistic sensitivity analyses were conducted to explore uncertainties. Where possible, all analyses focused on the only currently available left ventricular assist device (HeartMate 3TM, Abbott, Chicago, IL, USA) in the United Kingdom. Results The clinical effectiveness review included 134 studies (240 articles). There were no studies directly comparing HeartMate 3 and medical management (a randomised trial is ongoing). The currently available left ventricular assist device improves patient survival and reduces stroke rates and complications compared to earlier devices and relative to medical management. For example, survival at 24 months is 77% with the HeartMate 3 device compared to 59% with the HeartMate II (MOMENTUM 3 trial). An indirect comparison demonstrated a reduction in mortality compared to medical management [relative risk of death 0.25 (95% confidence interval 0.13 to 0.47); 24 months; this study]. The cost-effectiveness review included 5 cost analyses and 14 economic evaluations covering different generations of devices and with different perspectives. The reported incremental costs per quality-adjusted life-year gained compared to medical management were lower for later generations of devices [as low as £46,207 (2019 prices; United Kingdom perspective; time horizon at least 5 years)]. The economic evaluation used different approaches to obtain the relative effects of current left ventricular assist devices compared to medical management from the United Kingdom National Health Service/personal social service perspective. All gave similar incremental cost-effectiveness ratios of £53,496-58,244 per quality-adjusted life-year gained - lifetime horizon. Model outputs were sensitive to parameter estimates relating to medical management. The findings did not materially differ on exploratory subgroup analyses based on the severity of heart failure. Limitations There was no direct evidence comparing the clinical effectiveness of HeartMate 3 to medical management. Indirect comparisons made were based on limited data from heterogeneous studies regarding the severity of heart failure (Interagency Registry for Mechanically Assisted Circulatory Support score distribution) and possible for survival only. Furthermore, the cost of medical management of advanced heart failure in the United Kingdom is not clear. Conclusions Using cost-effectiveness criteria applied in the United Kingdom, left ventricular assist devices compared to medical management for patients with advanced heart failure ineligible for heart transplant may not be cost-effective. When available, data from the ongoing evaluation of HeartMate 3 compared to medical management can be used to update cost-effectiveness estimates. An audit of the costs of medical management in the United Kingdom is required to further decrease uncertainty in the economic evaluation. Study registration This study is registered as PROSPERO CRD42020158987. Funding This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: NIHR128996) and is published in full in Health Technology Assessment; Vol. 28, No. 38. See the NIHR Funding and Awards website for further award information.
Collapse
Affiliation(s)
- Sophie Beese
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Tuba S Avşar
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
- Institute of Epidemiology and Health, University College London, London, UK
| | - Malcolm Price
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - David Quinn
- Cardiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Hoong S Lim
- Cardiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Janine Dretzke
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Chidubem O Ogwulu
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Pelham Barton
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Louise Jackson
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - David Moore
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| |
Collapse
|
5
|
Hollis IB, Jennings DL, Krim S, Ton VK, Ducharme A, Cowger J, Looby M, Eulert-Green JJ, Bansal N, Horn E, Byku M, Katz J, Michaud CJ, Rajapreyar I, Campbell P, Vale C, Cosgrove R, Hernandez-Montfort J, Otero J, Ingemi A, Raj S, Weeks P, Agarwal R, Martinez ES, Tops LF, Ahmed MM, Kiskaddon A, Kremer J, Keebler M, Ratnagiri RK. An ISHLT consensus statement on strategies to prevent and manage hemocompatibility related adverse events in patients with a durable, continuous-flow ventricular assist device. J Heart Lung Transplant 2024; 43:1199-1234. [PMID: 38878021 DOI: 10.1016/j.healun.2024.04.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 07/15/2024] Open
Abstract
Life expectancy of patients with a durable, continuous-flow left ventricular assist device (CF-LVAD) continues to increase. Despite significant improvements in the delivery of care for patients with these devices, hemocompatability-related adverse events (HRAEs) are still a concern and contribute to significant morbility and mortality when they occur. As such, dissemination of current best evidence and practices is of critical importance. This ISHLT Consensus Statement is a summative assessment of the current literature on prevention and management of HRAEs through optimal management of oral anticoagulant and antiplatelet medications, parenteral anticoagulant medications, management of patients at high risk for HRAEs and those experiencing thrombotic or bleeding events, and device management outside of antithrombotic medications. This document is intended to assist clinicians caring for patients with a CF-LVAD provide the best care possible with respect to prevention and management of these events.
Collapse
Affiliation(s)
- Ian B Hollis
- University of North Carolina Eshelman School of Pharmacy, Chapel Hill, North Carolina; University of North Carolina Medical Center, Chapel Hill, North Carolina.
| | - Douglas L Jennings
- New York Presbyterian Columbia Irving Medical Center/Long Island University College of Pharmacy, New York, New York
| | - Selim Krim
- John Ochsner Heart and Vascular Institute, New Orleans, Louisiana
| | - Van-Khue Ton
- Massachusetts General Hospital, Boston, Massachusetts
| | - Anique Ducharme
- Montreal Heart Institute/Université de Montréal, Montreal, Quebec, Canada
| | | | - Mary Looby
- Inova Fairfax Medical Campus, Falls Church, Virginia
| | | | - Neha Bansal
- Mount Sinai Kravis Children's Hospital, New York, New York
| | - Ed Horn
- University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Mirnela Byku
- University of North Carolina Medical Center, Chapel Hill, North Carolina
| | - Jason Katz
- Division of Cardiology, NYU Grossman School of Medicine & Bellevue Hospital, New York, New York
| | | | | | | | - Cassandra Vale
- The Prince Charles Hospital, Chermside, Queensland, Australia
| | - Richard Cosgrove
- Cornerstone Specialty Hospital/University of Arizona College of Pharmacy, Tucson, Arizona
| | | | - Jessica Otero
- AdventHealth Littleton Hospital, Littleton, Colorado
| | | | | | - Phillip Weeks
- Memorial Hermann-Texas Medical Center, Houston, Texas
| | - Richa Agarwal
- Duke University Medical Center, Durham, North Carolina
| | | | - Laurens F Tops
- Leiden University Medical Center, Leiden, the Netherlands
| | | | - Amy Kiskaddon
- Johns Hopkins University School of Medicine, Baltimore, MD
| | | | - Mary Keebler
- University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | | |
Collapse
|
6
|
Flieder T, Blaesen S, Schulte K, Blasberg J, Lauenroth V, Knabbe C, Schramm R, Morshuis M, Gummert J, Birschmann I. Aspirin resistance in patients with ventricular assist devices: A follow-up study. Artif Organs 2024; 48:781-788. [PMID: 38553978 DOI: 10.1111/aor.14742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 02/07/2024] [Accepted: 02/26/2024] [Indexed: 06/12/2024]
Abstract
BACKGROUND Despite combined anticoagulation therapy consisting of a vitamin K antagonist and an antiplatelet agent, thromboembolic complications often occur in patients with a left ventricular assist device (LVAD). In addition, bleeding events are also common. Resistance to antiplatelet drugs is a well-known phenomenon; however, the utilization of laboratory chemistry testing for the presence of such resistance, and then switching therapy, is controversial. METHODS We tested 132 patients with LVAD (HeartWare n = 57, HeartMate II n = 22, HeartMate 3 n = 53) on acetylsalicylic acid (ASA) therapy for resistance and followed them for a maximum of 7 years regarding pump thrombosis. Light transmission aggregometry (LTA) and impedance aggregometry (IPA) were performed for testing platelet function. RESULTS We could show that patients with ASA resistance displayed an increased risk of pump thrombosis, regardless of the test used (LTA: OR = 6.20, CI [1.86-20.64], p = 0.003; IPA: OR = 12.14, CI [3.00-49.07], p < 0.001). In patients with a HeartMate 3, we could not detect any pump thrombosis associated with aspirin resistance. Furthermore, there was no significant difference in bleeding events between patients with ASA resistance and ASA responders. CONCLUSION Laboratory testing of ASA resistance seems to be a good tool to detect an increased risk of pump thrombosis, at least for patients with a HeartWare or HeartMate II. The extent to which these thromboses can be prevented with a change of medication has to be investigated in further studies. No pump thrombosis was detected in patients with a HeartMate 3, and the question should be asked as to what constellation of underlying and concomitant diseases must be present to justify ASA therapy for these patients.
Collapse
Affiliation(s)
- Tobias Flieder
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Institut für Laboratoriums- und Transfusionsmedizin, Bad Oeynhausen, Germany
| | - Sonja Blaesen
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Institut für Laboratoriums- und Transfusionsmedizin, Bad Oeynhausen, Germany
| | - Katrin Schulte
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Institut für Laboratoriums- und Transfusionsmedizin, Bad Oeynhausen, Germany
| | - Jost Blasberg
- Institut für Psychosoziale Medizin, Psychotherapie und Psychoonkologie, Universitätsklinikum Jena, Friedrich-Schiller-Universität, Jena, Germany
| | - Volker Lauenroth
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Klinik für Thorax- und Kardiovaskularchirurgie, Bad Oeynhausen, Germany
| | - Cornelius Knabbe
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Institut für Laboratoriums- und Transfusionsmedizin, Bad Oeynhausen, Germany
| | - René Schramm
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Klinik für Thorax- und Kardiovaskularchirurgie, Bad Oeynhausen, Germany
| | - Michiel Morshuis
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Klinik für Thorax- und Kardiovaskularchirurgie, Bad Oeynhausen, Germany
| | - Jan Gummert
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Klinik für Thorax- und Kardiovaskularchirurgie, Bad Oeynhausen, Germany
| | - Ingvild Birschmann
- Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Institut für Laboratoriums- und Transfusionsmedizin, Bad Oeynhausen, Germany
| |
Collapse
|
7
|
Liu X, Shao J, Wang P, Zhao H, Liu L, Han Q. Optimization design of semi-open impeller based on thrombogenicity in a blood pump. Artif Organs 2024. [PMID: 38922991 DOI: 10.1111/aor.14813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 05/13/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024]
Abstract
BACKGROUND Blood clots are composed of aggregated fibrin and platelets, and thrombosis is the body's natural response to repairing injured blood vessels or stopping bleeding. However, when this process is activated abnormally, such as in a mechanical blood pump, it can lead to excessive thrombus formation. Therefore, how to avoid or reduce the probability of thrombus formation is an important indicator of the stable operation of a blood pump. METHODS In this paper, Lagrangian particle tracking trajectories are simulated to study platelet transport in a blood pump. The design of the thrombus blood pump was optimized using an orthogonal design method based on three factors: inlet angle, outlet angle, and blade number. The effect of blood pump pressure, rotational speed, impeller outlet angle, inlet angle, and number of blades on thrombus formation was analysed using Fluent software. The thrombogenic potential was derived by analyzing the trajectory and flow parameters of platelet particles in the blood pump, as well as the statistical parameters of residence time and stress accumulation thrombus in the platelet pump. RESULTS When the impeller inlet angle is 30°, the outlet angle is 20°, and the number of blades is 6, the probability of thrombus formation is minimized in the orthogonal design method, aligning with the requirements for blood pump performance. CONCLUSIONS These design parameters serve as a numerical guideline for optimizing the geometry of the semi-open impeller in blood pumps and provide a theoretical foundation for subsequent in vitro experiments.
Collapse
Affiliation(s)
- Xuemin Liu
- School of Mechanical Engineering, University of Jinan, Jinan, China
| | - Jiejie Shao
- Ningbo Zhongjie Laitong Technology Co., Ltd., Ningbo, China
| | - Peng Wang
- School of Mechanical Engineering, University of Jinan, Jinan, China
| | - Honghua Zhao
- School of Mechanical Engineering, University of Jinan, Jinan, China
| | - Luning Liu
- School of Mechanical Engineering, University of Jinan, Jinan, China
| | - Qing Han
- School of Mechanical Engineering, University of Jinan, Jinan, China
| |
Collapse
|
8
|
Kohs TCL, Weeder BR, Chobrutskiy BI, Kartika T, Moore KK, McCarty OJT, Zonies D, Zakhary B, Shatzel JJ. Predictors of thrombosis during VV ECMO: an analysis of 9809 patients from the ELSO registry. J Thromb Thrombolysis 2024; 57:345-351. [PMID: 38095743 DOI: 10.1007/s11239-023-02909-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/22/2023] [Indexed: 03/26/2024]
Abstract
Venovenous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving therapy for critically ill patients, but it carries an increased risk of thrombosis due to blood interacting with non-physiological surfaces. While the relationship between clinical variables and thrombosis remains unclear, our study aimed to identify which factors are most predictive of thrombosis. The Extracorporeal Life Support Organization Registry was queried to obtain a cohort of VV-ECMO patients aged 18 years and older from 2015 to 2019. Patients who were over 80-years-old, at the extremes of weight, who received less than 24 h of ECMO, multiple rounds of ECMO, or had missing data were excluded. Multivariate logistic regression modeling was used to assess predictors of thrombosis and mortality. A total of 9809 patients were included in the analysis, with a mean age of 47.1 ± 15.1 years and an average ECMO run time of 305 ± 353 h. Thrombosis occurred in 19.9% of the cohort, with circuit thrombosis (8.6%) and membrane lung failure (6.1%) being the most common. Multivariate analysis showed that ECMO runs over 14 days (OR: 2.62, P < 0.001) and pregnancy-related complications (OR: 1.79, P = 0.004) were associated with an increased risk of thrombosis. Risk factors for circuit thrombosis included incremental unit increases in the pump flow rate at 24 h (OR: 1.07 [1.00-1.14], P = 0.044) and specific cannulation sites. Increased body weight (OR: 1.02 [1.00-1.04], P = 0.026) and increased duration on ECMO (OR: 3.82 [3.12-4.71], P < 0.001) were predictive of membrane lung failure. Additionally, patients with thrombosis were at increased likelihood of in-hospital mortality (OR: 1.52, P < 0.001). This study identified multiple thrombotic risk factors in VV-ECMO, suggesting that future studies investigating the impact of pregnancy associated complications and ECMO flow rate on hemostasis would be illuminating.
Collapse
Affiliation(s)
- Tia C L Kohs
- Department of Biomedical Engineering, Oregon Health & Science University, 3303 S. Bond Avenue, Portland, OR, 97239, USA.
| | - Benjamin R Weeder
- Program in Molecular and Cellular Biology, Oregon Health & Science University, Portland, OR, USA
| | - Boris I Chobrutskiy
- Department of Internal Medicine, Oregon Health & Science University, Portland, OR, USA
| | - Thomas Kartika
- Department of Internal Medicine, Oregon Health & Science University, Portland, OR, USA
| | - Kerry K Moore
- Department of Pharmacy, Oregon Health & Science University, Portland, OR, USA
| | - Owen J T McCarty
- Department of Biomedical Engineering, Oregon Health & Science University, 3303 S. Bond Avenue, Portland, OR, 97239, USA
| | - David Zonies
- Department of Surgery, Division of Trauma, Critical Care and Acute Care Surgery, Oregon Health & Science University, Portland, OR, USA
| | - Bishoy Zakhary
- Department of Pulmonary and Critical Care Medicine, Oregon Health & Science University, Portland, OR, USA
| | - Joseph J Shatzel
- Department of Biomedical Engineering, Oregon Health & Science University, 3303 S. Bond Avenue, Portland, OR, 97239, USA
- Division of Hematology and Oncology, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
9
|
Alba AC, Kirklin JK, Cantor RS, Deng L, Ross HJ, Jacobs JP, Rao V, Hanff TC, Stehlik J. The impact of obesity and LVAD-bridging on heart transplant candidate outcomes: a linked STS INTERMACS - OPTN/UNOS data analysis. J Heart Lung Transplant 2023; 42:1587-1596. [PMID: 37385418 PMCID: PMC10640766 DOI: 10.1016/j.healun.2023.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/17/2023] [Accepted: 06/04/2023] [Indexed: 07/01/2023] Open
Abstract
BACKGROUND Limited data integrating waitlist and postheart transplant (HT) mortality have evaluated outcomes of left ventricular assist device (LVAD)-bridged strategy vs no LVAD according to patient characteristics. We evaluated waitlist and post-HT mortality in LVAD-bridged vs nonbridged patients based on body mass index (BMI). METHODS We included linked adults listed for HT in Organ Procurement and Transplant Network/United Network for Organ Sharing and patients receiving durable LVAD as bridge to HT or candidacy in Society of Thoracic Surgeons/Interagency Mechanical Circulatory Support databases (2010-2019). Using BMI at listing or LVAD implant, we categorized patients as underweight (<18.5 kg/m2), normal weight (18.5-24.99 kg/m2), overweight (25-29.99 kg/m2), and obese (≥30 kg/m2). Kaplan-Meier analysis and multivariable Cox proportional hazards models informed the effect of LVAD-bridged and nonbridged strategy by BMI on waitlist, post-HT, and overall mortality (including waitlist and post-HT mortality). RESULTS Among 11,216 LVAD-bridged and 17,122 nonbridged candidates, bridged candidates were more frequently obese (37.3% vs 28.6%) (p < 0.001). Multivariable analysis indicated increased waitlist mortality in LVAD-bridged vs nonbridged with overweight (Hazard ratio (HR) 1.18, 95% confidence interval (CI) 1.02-1.36) or obesity (HR 1.35, 95%CI 1.17-1.56) in comparison to normal weight candidates (HR 1.02, 95%CI 0.88-1.19) (p-interaction < 0.001). Post-transplant mortality was not statistically different in LVAD-bridged vs nonbridged patients across BMI categories (p-interaction = 0.26). There was a nonsignificant graded increase in overall mortality in LVAD-bridged with overweight (HR 1.53, 95%CI 1.39-1.68) or obesity (HR 1.61, 95%CI 1.46-1.78) compared to nonbridged patients (p-interaction = 0.13). CONCLUSIONS LVAD-bridged candidates with obesity had higher waitlist mortality compared to nonbridged candidates with obesity. Post-transplant mortality was similar in LVAD-bridged and nonbridged patients, but obesity remained associated with increased mortality in both groups. This study may aid clinicians and advanced heart failure patients with obesity in decision-making.
Collapse
Affiliation(s)
- Ana C Alba
- Peter Munk Cardiac Centre, University Health Network, Toronto, Canada.
| | | | - Ryan S Cantor
- University of Alabama at Birmingham, Birmingham, Washington
| | - Luqin Deng
- University of Alabama at Birmingham, Birmingham, Washington
| | - Heather J Ross
- Peter Munk Cardiac Centre, University Health Network, Toronto, Canada
| | | | - Vivek Rao
- Peter Munk Cardiac Centre, University Health Network, Toronto, Canada
| | - Thomas C Hanff
- University of Utah School of Medicine, Salt Lake City, Utah
| | - Josef Stehlik
- University of Utah School of Medicine, Salt Lake City, Utah
| |
Collapse
|
10
|
Birk SE, Baran DA, Campbell R, Herre JM, Sadatsafavi H, Yehya A. Clinical outcomes of ventricular assist device support by HIV infection status: An STS-INTERMACS analysis. J Heart Lung Transplant 2023; 42:1185-1193. [PMID: 37146667 DOI: 10.1016/j.healun.2023.04.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 04/25/2023] [Accepted: 04/27/2023] [Indexed: 05/07/2023] Open
Abstract
BACKGROUND Cardiovascular disease remains the leading cause of mortality in human immunodeficiency virus-infected (HIV-positive) patients. Ventricular assist device therapy is rarely offered to these patients and data on outcomes are sparse. We investigated outcomes following ventricular assist device implants for HIV-positive as compared to non-HIV-infected (HIV-negative) patients. METHODS We analyzed 22,065 patients from the Interagency Registry for Mechanically Assisted Circulatory Support registry for outcomes by HIV status. A propensity-matched analysis adjusting for 21 preimplant risk factors was also conducted. RESULTS Compared with 21,980 HIV-negative device recipients, the 85 HIV-positive recipients were younger (median age 58 years vs 59 years, p = 0.02), had lower body mass index (26 kg/m2 vs 29 kg/m2, p = 0.001), and had higher rates of prior stroke (8% vs 4%, p = 0.02). In the matched HIV-positive and HIV-negative cohorts, there was significantly higher mortality in HIV-positive patients in earlier implant years, however, this association was not seen in later implant years (2018-2020). In both unmatched and matched cohorts, no significant differences in postimplantation stroke, major bleeding, or major infection were noted. CONCLUSIONS With recent advancements in mechanical circulatory support and HIV treatment, ventricular assist device therapy is a viable therapeutic option for HIV-positive patients with end-stage heart failure.
Collapse
Affiliation(s)
| | - David A Baran
- Cleveland Clinic, Heart Vascular and Thoracic Institute, Weston, FL
| | - Robert Campbell
- NIH-NHLBI PRIDE AGOLD Program, University of Colorado Anschutz Medical Campus, Aurora, CO
| | - John M Herre
- Eastern Virginia Medical School, Norfolk, VA; Sentara Norfolk General Hospital, Norfolk, VA
| | - Hessam Sadatsafavi
- Sentara Health System Enterprise Analytics, Sentara Norfolk General Hospital, Norfolk, VA
| | - Amin Yehya
- Eastern Virginia Medical School, Norfolk, VA; Sentara Norfolk General Hospital, Norfolk, VA.
| |
Collapse
|
11
|
Bernhardt AM, Copeland H, Deswal A, Gluck J, Givertz MM. The International Society for Heart and Lung Transplantation/Heart Failure Society of America Guideline on Acute Mechanical Circulatory Support. J Heart Lung Transplant 2023; 42:e1-e64. [PMID: 36805198 DOI: 10.1016/j.healun.2022.10.028] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 10/28/2022] [Indexed: 02/08/2023] Open
Affiliation(s)
- Alexander M Bernhardt
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany.
| | - Hannah Copeland
- Department of Cardiac Surgery, Lutheran Health Physicians, Fort Wayne, Indiana
| | - Anita Deswal
- Department of Cardiology, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Jason Gluck
- Heart and Vascular Institute, Hartford Hospital, Hartford, Connecticut
| | - Michael M Givertz
- Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
12
|
Bernhardt AM, Copeland H, Deswal A, Gluck J, Givertz MM. The International Society for Heart and Lung Transplantation/Heart Failure Society of America Guideline on Acute Mechanical Circulatory Support. J Card Fail 2023; 29:304-374. [PMID: 36754750 DOI: 10.1016/j.cardfail.2022.11.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Alexander M Bernhardt
- Department of Cardiovascular Surgery, University Heart and Vascular Center Hamburg, Hamburg, Germany.
| | - Hannah Copeland
- Department of Cardiac Surgery, Lutheran Health Physicians, Fort Wayne, Indiana
| | - Anita Deswal
- Department of Cardiology, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Jason Gluck
- Heart and Vascular Institute, Hartford Hospital, Hartford, Connecticut
| | - Michael M Givertz
- Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
| |
Collapse
|
13
|
Tarzia V, Tessari C, Bagozzi L, Bottigliengo D, Fagan D, Fabozzo A, Mastro FR, Pagnin C, Bottio T, Gregori D, Gerosa G. Anticoagulation alone as an effective and safe antithrombotic therapy in LVAD: When less is more. Curr Probl Cardiol 2023; 48:101506. [PMID: 36402214 DOI: 10.1016/j.cpcardiol.2022.101506] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 11/11/2022] [Indexed: 11/18/2022]
Abstract
To evaluate the safety and effectiveness of anticoagulation alone in HeartMate3 patients. According to antithrombotic regimen, patients were divided into 2 groups: Group-1(warfarin+aspirin) and Group-2(warfarin). A comparison of hemocompatibility-related adverse events (HRAEs), hemocompatibility score (HCS), and hemocoagulative laboratory markers, both qualitative and quantitative, between the 2 groups were performed. Fifty patients were enrolled, 28 (56%) in Group-1 and 22 in Group-2 (44%), without statistical differences at baseline. Median time of follow-up was 590 days (IQR: 410.25-1007.50). Eighteen HRAEs (36.0%) occurred: 17 in Group-1 (34%) and 1 in Group-2 (2%) (P < 0.001). The net HCS for Group-1 versus Group-2 was 24 points and 1 point (OR 12.116[2.034-233.226], P = 0.023), respectively. Hemocoagulative values turned into the normality and remained stable during follow-up, without differences between groups, except for ASPI-test (P = 0.003). HeartMate3 showed a high hemocompatibility independently from antithrombotic therapy. Aspirin avoidance resulted a safe and effective strategy since it reduced hemorrhagic events, without increasing thrombotic risk.
Collapse
Affiliation(s)
- Vincenzo Tarzia
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy.
| | - Chiara Tessari
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Lorenzo Bagozzi
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Daniele Bottigliengo
- Biostatistics, Epidemiology and Public Health Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Davide Fagan
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Assunta Fabozzo
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Florinda Rosaria Mastro
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Chiara Pagnin
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Tomaso Bottio
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Dario Gregori
- Biostatistics, Epidemiology and Public Health Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| | - Gino Gerosa
- Cardiac-Surgery-Unit, Department of Cardio-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy
| |
Collapse
|
14
|
Biological Response to Sintered Titanium in Left Ventricular Assist Devices: Pseudoneointima, Neointima, and Pannus. ASAIO J 2023; 69:1-10. [PMID: 35649199 DOI: 10.1097/mat.0000000000001777] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Titanium alloys have traditionally been used in blood-contacting cardiovascular devices, including left ventricular assist devices (LVADs). However, titanium surfaces are susceptible to adverse coagulation, leading to thrombogenesis and stroke. To improve hemocompatibility, LVAD manufacturers introduced powder sintering on blood-wetted surfaces in the 1980s to induce endothelialization. This technique has been employed in multiple contemporary LVADs on the pump housing, as well as the interior and exterior of the inflow cannula. Despite the wide adoption of sintered titanium, reported biologic response over the past several decades has been highly variable and apparently unpredictable-including combinations of neointima, pseudoneoimtima, thrombus, and pannus. We present a history of sintered titanium used in LVAD, a review of accumulated clinical outcomes, and a synopsis of gross appearance and composition of various depositions found clinically and in animal studies, which is unfortunately confounded by the variability and inconsistency in terminology. Therefore, this review endeavors to introduce a unified taxonomy to harmonize published observations of biologic response to sintered titanium in LVADs. From these data, we are able to deduce the natural history of the biologic response to sintered titanium, toward development of a deterministic model of the genesis of a hemocompatible neointima.
Collapse
|
15
|
Wu P. Recent advances in the application of computational fluid dynamics in the development of rotary blood pumps. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
|
16
|
Truong VT, Egnaczyk GF, O'Brien TM, Raymond TE, Gilardi S, Shreenivas SS, Geoffrey AA, Chung ES. Left Ventricular Assist Device in Patients With Alcohol Abuse or Illicit Drug Use. Am J Cardiol 2022; 177:61-68. [PMID: 35697544 DOI: 10.1016/j.amjcard.2022.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 04/12/2022] [Accepted: 05/16/2022] [Indexed: 11/01/2022]
Abstract
The impact of substance abuse, including alcohol abuse or illicit drug use, on outcomes after left ventricular assist device (LVAD) implantation, has not been fully elucidated. Accordingly, to test the hypothesis that such a history would be associated with worse outcomes, we analyzed the Interagency Registry for Mechanically Assisted Circulatory Support registry. All patients from the Interagency Registry for Mechanically Assisted Circulatory Support registry who received a continuous-flow LVAD from June 2006 to December 2017 were included. The median follow-up duration was 12.9 months (interquartile range, 5.3 to 17.5). The final study group consisted of 15,069 patients, of which 1,184 (7.9%) had a history of alcohol abuse and 1,139 (7.6%) had a history of illicit drug use. The overall mortality rates in the alcohol, illicit drug, and control groups were 25%, 21%, and 29%, respectively. Cox regression analysis showed that having a history of alcohol abuse (hazard ratio, 0.97, 95% confidence interval, 0.84 to 1.13, p = 0.72) or illicit drug use (hazard ratio, 1.02, 95% confidence interval, 0.86 to 1.21, p = 0.81) was not significantly associated with increased risk of all-cause mortality when compared with general LVAD population. On the contrary, after adjusting for other covariates, a history of alcohol abuse or illicit drug use was significantly associated with increased device malfunction/pump thrombosis, device-related infection, or all-cause hospitalization (all p <0.05). Furthermore, After LVAD implantation, these patients had a lower quality of life assessed by the Kansas City Cardiomyopathy Questionnaire compared with those who did not. In conclusion, our findings suggest that patients with a history of alcohol abuse or illicit drug use are at risk for adverse device-related events with a lower quality of life after continuous-flow LVAD implantation compared with the general LVAD population.
Collapse
Affiliation(s)
- Vien T Truong
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio; The Sue and Bill Butler Research Fellow, Lindner Research Center, Cincinnati, Ohio
| | - Gregory F Egnaczyk
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Thomas M O'Brien
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Timothy E Raymond
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Stephanie Gilardi
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Satya S Shreenivas
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Answini A Geoffrey
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio
| | - Eugene S Chung
- The Christ Hospital Health Network Cincinnati, Lindner Research Center, Cincinnati, Ohio.
| |
Collapse
|
17
|
Ito H, Kameyama A, Kawakami M, Yokoyama S, Yamazaki M. Warfarin Reversal With Four-Factor Prothrombin Complex Concentrate for Left Ventricular Assist Device Conversion Surgery Monitored by TEG6s: A Case Report. Cureus 2022; 14:e27745. [PMID: 36106226 PMCID: PMC9446883 DOI: 10.7759/cureus.27745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/07/2022] [Indexed: 11/05/2022] Open
Abstract
Left ventricular assist devices (LVADs) require careful therapeutic anticoagulation with warfarin to prevent pump thrombosis. However, the best method to reverse warfarin for elective LVAD conversion surgery with massive bleeding remains unclear. We report the case of a 39-year-old Japanese man who was administered a four-factor prothrombin complex concentrate (4F-PCC) as warfarin reversal when he underwent conversion surgery from paracorporeal LVAD to implantable LVAD. 4F-PCC with co-administration of vitamin K reduced the international normalized ratio and R time in TEG6s (Haemonetics Corporation, USA) immediately. The effect was prolonged, and good hemostasis was achieved. 4F-PCC with vitamin K provided good hemostasis in our patient; therefore, 4F-PCC could be a useful tool for elective LVAD conversion surgery with expected massive bleeding and requiring immediate warfarin reversal.
Collapse
|
18
|
Left ventricular assist device and pump thrombosis: the importance of the inflow cannula position. Int J Cardiovasc Imaging 2022; 38:2771-2779. [DOI: 10.1007/s10554-022-02683-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 06/21/2022] [Indexed: 11/26/2022]
Abstract
AbstractPump thrombosis is a devastating complication after left ventricular assist device implantation. This study aims to elucidate the relation between left ventricular assist device implantation angle and risk of pump thrombosis. Between November 2010 and March 2020, 53 left ventricular assist device-patients underwent a computed tomography scan. Using a 3-dimensional multiplanar reformation the left ventricular axis was reconstructed to measure the implantation angle of the inflow cannula. All patients were retrospectively analyzed for the occurrence of pump thrombosis. In 10 (91%) patients with a pump thrombosis, the implantation angle was towards the lateral wall of the left ventricle. In only 20 patients (49%) of the patients without a pump thrombosis the inflow cannula pointed towards the lateral wall of the left ventricle. The mean angle in patients with a pump thrombosis was 10.1 ± 11.9 degrees towards the lateral wall of the left ventricle compared to 4.1 ± 19.9 degrees towards the septum in non-pump thrombosis patients (P = 0.005). There was a trend towards a significant difference in time to first pump thrombosis between patients with a lateral or septal deviated left ventricular assist device (hazard ratio of 0.15, P = 0.07). This study demonstrates that left ventricular assist device implantation angle is associated with pump thrombosis. Almost all patients in whom a pump thrombosis occurred during follow-up had a left ventricular assist device implanted with the inflow-cannula pointing towards the lateral wall of the left ventricle.
Collapse
|
19
|
Tramontin C, Affronti A, Cirio EM. Diagnostic and surgical management of HeartMate 3 outflow graft obstruction due to two different mechanisms. Asian Cardiovasc Thorac Ann 2022; 30:826-829. [PMID: 35675103 DOI: 10.1177/02184923221106765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Outflow graft obstruction is a potentially catastrophic complication of left ventricular assist devices that may occur secondary to different mechanisms. Two cases of Heartmate 3 outflow graft obstruction associated with two different pathophysiological mechanisms are presented. The first one was a 70-year-old man who developed outflow graft obstruction secondary to kinking. The second case was a 72-year-old man who presented with signs and symptoms of heart failure due to outflow graft extrinsic obstruction. Both cases were diagnosed with 3D-CT scan and successfully surgically treated.
Collapse
Affiliation(s)
- Corrado Tramontin
- Division of Cardiac Surgery, Azienda di Rilievo Nazionale e Alta Specializzazione "G. Brotzu", Cagliari, Italy
| | - Alessandro Affronti
- Cardiovascular Surgery Department, 16493Hospital Clínic, University of Barcelona, Barcelona, Spain
| | - Emiliano Maria Cirio
- Division of Cardiac Surgery, Azienda di Rilievo Nazionale e Alta Specializzazione "G. Brotzu", Cagliari, Italy
| |
Collapse
|
20
|
Stio RE, Montalto A, Intorcia A, Polizzi V, Feccia M, Musto C, Pennacchi M, Paolucci L, Stumpo R, D’Avino E, De Felice F, Gabrielli D, Musumeci F. A Case of Successful Use of the "Anchoring Technique" for Percutaneous Treatment of Left Ventricular Assist Device Graft Occlusion. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:2441. [PMID: 35206629 PMCID: PMC8879255 DOI: 10.3390/ijerph19042441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/16/2022] [Accepted: 02/18/2022] [Indexed: 01/21/2023]
Abstract
Left ventricular assist device (LVAD) obstruction can be a dramatic and life-threatening complication in patients with advanced heart failure (HF). Despite surgical redo is often required in these patients, it is associated with a high risk of periprocedural negative outcome. We report the case of a 68-year-old male with a thrombotic stenosis of the LVAD proximal outflow-graft. Following Heart Team debate, a percutaneous intervention was planned during veno-arterial Extra Corporeal Membrane Oxygenation (ECMO) assistance. To achieve the needed catheter support, we used the "distal balloon anchoring technique" through the outflow-graft and managed to implant a covered stent, rapidly restoring the flow through the LVAD. The patient was discharged without further complications. Our case shows that, in selected cases, percutaneous treatment of LVAD obstructions can be feasible, especially using advanced techniques derived from the experiences in coronary interventions and under ECMO assistance. More cases and prospective studies are mostly needed to explore long-term patency of the LVADs and clinical outcomes in these high-risk patients.
Collapse
Affiliation(s)
- Rocco Edoardo Stio
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Andrea Montalto
- Cardiac Surgery Unit and Heart Transplantation Center, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.M.); (V.P.); (M.F.); (F.M.)
| | - Alfredo Intorcia
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Vincenzo Polizzi
- Cardiac Surgery Unit and Heart Transplantation Center, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.M.); (V.P.); (M.F.); (F.M.)
| | - Mariano Feccia
- Cardiac Surgery Unit and Heart Transplantation Center, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.M.); (V.P.); (M.F.); (F.M.)
| | - Carmine Musto
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Mauro Pennacchi
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Luca Paolucci
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Regina Stumpo
- Division of Vascular Surgery, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy;
| | - Emilio D’Avino
- Department of Cardiovascular Anaesthesia, San Camillo-Forlanini Hospital, 00152 Rome, Italy;
| | - Francesco De Felice
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Domenico Gabrielli
- Division of Interventional Cardiology, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.I.); (C.M.); (M.P.); (L.P.); (F.D.F.); (D.G.)
| | - Francesco Musumeci
- Cardiac Surgery Unit and Heart Transplantation Center, Department of Heart and Vessels, San Camillo-Forlanini Hospital, 00152 Rome, Italy; (A.M.); (V.P.); (M.F.); (F.M.)
| |
Collapse
|
21
|
Hendren NS, Segar MW, Zhong L, Michelis KC, Drazner MH, Young JB, Tang WHW, Pandey A, Grodin JL. Phenomapping a Novel Classification System for Patients With Destination Therapy Left Ventricular Assist Devices. Am J Cardiol 2022; 164:93-99. [PMID: 34815060 DOI: 10.1016/j.amjcard.2021.10.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 09/30/2021] [Accepted: 10/04/2021] [Indexed: 11/16/2022]
Abstract
Patients with continuous flow destination therapy (DT) left ventricular assist devices (LVAD) comprise a heterogeneous population. We hypothesized that phenotypic clustering of individuals with DT LVADs by their implantation characteristics will be associated with different long-term risk profiles. We analyzed 5,999 patients with continuous flow DT LVADs in Interagency Registry for Mechanically Assisted Circulatory Support using 18 continuous variable baseline characteristics. We Z-transformed the variables and applied a Gaussian finite mixture model to perform unsupervised clustering resulting in identification of 4 phenogroups. Survival analyses considered the competing risk for cumulative incidence of transplant or the composite end point of death or heart transplant where appropriate. Phenogroup 1 (n = 1,163, 19%) was older (71 years) and primarily white (81%). Phenogroups 2 (n = 648, 11%) and 3 (n = 3,671, 61%) were of intermediate age (70 and 62 years), weight (85 and 87 kg), and ventricular size. Phenogroup 4 (n = 517, 9%) was younger (40 years), heavier (108 kg), and more racially diverse. The cumulative incidence of death, heart transplant, bleeding, LVAD malfunction, and LVAD thrombosis differed among phenogroups. The highest incidence of death and the lowest rate of heart transplant was seen in phenogroup 1 (p <0.001). For adverse outcomes, phenogroup 4 had the lowest incidence of bleeding, whereas LVAD device thrombosis and malfunction were lowest in phenogroup 1 (p <0.001 for all). Finally, the incidence of stroke, infection, and renal dysfunction were not statistically different. In conclusion, the present unsupervised machine learning analysis identified 4 phenogroups with different rates of adverse outcomes and these findings underscore the influence of phenotypic heterogeneity on post-LVAD implantation outcomes.
Collapse
Affiliation(s)
- Nicholas S Hendren
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas; Parkland Health and Hospital System, Dallas, Texas
| | - Matthew W Segar
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas; Parkland Health and Hospital System, Dallas, Texas
| | - Lin Zhong
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Katherine C Michelis
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas; Division of Cardiology, Department of Internal Medicine, North Texas VA Medical Center, Dallas, Texas
| | - Mark H Drazner
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas
| | - James B Young
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio
| | - W H Wilson Tang
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio
| | - Ambarish Pandey
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas; Parkland Health and Hospital System, Dallas, Texas
| | - Justin L Grodin
- Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas; Parkland Health and Hospital System, Dallas, Texas.
| |
Collapse
|
22
|
Hariri IM, Dardas T, Kanwar M, Cogswell R, Gosev I, Molina E, Myers SL, Kirklin JK, Shah P, Pagani FD, Cowger JA. Long-term survival on LVAD support: Device complications and end-organ dysfunction limit long-term success. J Heart Lung Transplant 2022; 41:161-170. [PMID: 34404571 PMCID: PMC8784570 DOI: 10.1016/j.healun.2021.07.011] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 06/18/2021] [Accepted: 07/11/2021] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Preoperative variables can predict short term left ventricular assist device (LVAD) survival, but predictors of extended survival remain insufficiently characterized. METHOD Patients undergoing LVAD implant (2012-2018) in the Intermacs registry were grouped according to time on support: short-term (<1 year, n = 7,483), mid-term (MT, 1-3 years, n = 5,976) and long-term (LT, ≥3 years, n = 3,015). Landmarked hazard analyses (adjusted hazard ratio, HR) were performed to identify correlates of survival after 1 and 3 years of support. RESULTS After surviving 1 year of support, additional LVAD survival was less likely in older (HR 1.15 per decade), Caucasian (HR 1.22) and unmarried (HR 1.16) patients (p < 0.05). After 3 years of support, only 3 preoperative characteristics (age, race, and history of bypass surgery, p < 0.05) correlated with extended survival. Postoperative events most negatively influenced achieving LT survival. In those alive at 1 year or 3 years, the occurrence of postoperative renal (creatinine HR MT = 1.09; LT HR = 1.10 per mg/dl) and hepatic dysfunction (AST HR MT = 1.29; LT HR = 1.34 per 100 IU), stroke (MT HR = 1.24; LT HR = 1.42), infection (MT HR = 1.13; LT HR = 1.10), and/or device malfunction (MT HR = 1.22; LT HR = 1.46) reduced extended survival (all p ≤ 0.03). CONCLUSIONS Success with LVAD therapy hinges on achieving long term survival in more recipients. After 1 year, extended survival is heavily constrained by the occurrence of adverse events and postoperative end-organ dysfunction. The growth of destination therapy intent mandates that future LVAD studies be designed with follow up sufficient for capturing outcomes beyond 24 months.
Collapse
Affiliation(s)
| | | | | | | | | | - Ezequiel Molina
- MedStar Heart & Vascular Institute/MedStar Washington Hospital Center, Washington, DC
| | | | | | - Palak Shah
- Inova Heart & Vascular Institute, Falls Church, VA
| | | | | |
Collapse
|
23
|
Nunez JI, Gosling AF, O'Gara B, Kennedy KF, Rycus P, Abrams D, Brodie D, Shaefi S, Garan AR, Grandin EW. Bleeding and thrombotic events in adults supported with venovenous extracorporeal membrane oxygenation: an ELSO registry analysis. Intensive Care Med 2021; 48:213-224. [PMID: 34921625 DOI: 10.1007/s00134-021-06593-x] [Citation(s) in RCA: 111] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 11/24/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE This study aimed at analyzing the prevalence, mortality association, and risk factors for bleeding and thrombosis events (BTEs) among adults supported with venovenous extracorporeal membrane oxygenation (VV-ECMO). METHODS We queried the Extracorporeal Life Support Organization registry for adults supported with VV-ECMO from 2010 to 2017. Multivariable logistic regression modeling was used to assess the association between BTEs and in-hospital mortality and the predictors of BTEs. RESULTS Among 7579 VV-ECMO patients meeting criteria, 40.2% experienced ≥ 1 BTE. Thrombotic events comprised 54.9% of all BTEs and were predominantly ECMO circuit thrombosis. BTE rates decreased significantly over the study period (p < 0.001). The inpatient mortality rate was 34.9%. Bleeding events (1.69 [1.49-1.93]) were more strongly associated with in-hospital mortality than thrombotic events (1.23 [1.08-1.41]) p < 0.01 for both. The BTEs most strongly associated with mortality were ischemic stroke (4.50 [2.55-7.97]) and medical bleeding, including intracranial (5.71 [4.02-8.09]), pulmonary (2.02 [1.54-2.67]), and gastrointestinal (1.54 [1.2-1.98]) hemorrhage, all p < 0.01. Risk factors for bleeding included acute kidney injury and pre-ECMO vasopressor support and for thrombosis were higher weight, multisite cannulation, pre-ECMO arrest, and higher PaCO2 at ECMO initiation. Longer time on ECMO, younger age, higher pH, and earlier year of support were associated with bleeding and thrombosis. CONCLUSIONS Although decreasing over time, BTEs remain common during VV-ECMO and have a strong, cumulative association with in-hospital mortality. Thrombotic events are more frequent, but bleeding carries a higher risk of inpatient mortality. Differential risk factors for bleeding and thrombotic complications exist, raising the possibility of a tailored approach to VV-ECMO management.
Collapse
Affiliation(s)
- Jose I Nunez
- Department of Medicine, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Andre F Gosling
- Department of Anesthesiology, Duke University Hospital, Durham, NC, USA
| | - Brian O'Gara
- Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Kevin F Kennedy
- Smith Center for Cardiology Outcomes Research, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - Peter Rycus
- Extracorporeal Life Support Organization, Ann Arbor, MI, USA
| | - Darryl Abrams
- Division of Pulmonary and Critical Care Medicine, Columbia Presbyterian Medical Center, New York, NY, USA
| | - Daniel Brodie
- Division of Pulmonary and Critical Care Medicine, Columbia Presbyterian Medical Center, New York, NY, USA
| | - Shahzad Shaefi
- Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA
| | - A Reshad Garan
- Division of Cardiovascular Medicine, Section of Advanced Heart Failure, Department of Medicine, Beth Israel Deaconess Medical Center, 185 Pilgrim Road, DE-319, Boston, MA, 02215, USA
| | - E Wilson Grandin
- Smith Center for Cardiology Outcomes Research, Beth Israel Deaconess Medical Center, Boston, MA, USA. .,Division of Cardiovascular Medicine, Section of Advanced Heart Failure, Department of Medicine, Beth Israel Deaconess Medical Center, 185 Pilgrim Road, DE-319, Boston, MA, 02215, USA.
| |
Collapse
|
24
|
Zakrzewski J, Coyle L, Aicher T, Chickerillo K, Gallagher C, Kuper K, Sciamanna C, Chau VQ, Tatooles A. Impact of COVID-19 on Patients Supported with a Left Ventricular Assist Device. ASAIO J 2021; 67:1189-1195. [PMID: 34475334 PMCID: PMC8555883 DOI: 10.1097/mat.0000000000001578] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Patients on left ventricular assist device (LVAD) support may be susceptible to severe disease and complications from coronavirus disease-19 (COVID-19). The purpose of this study was to describe the clinical course of COVID-19 in LVAD patients. A retrospective review was performed at our center; 28 LVAD patients who developed COVID-19 between March 2020 and March 2021, and six patients with a prior COVID-19 infection who underwent LVAD implantation, were identified and examined. Of the 28 patients, nine (32%) died during the study period, five (18%) during their index hospitalization for COVID-19. Two patients (7%) presented with suspected pump thrombosis. In a nonadjusted binary regression logistic analysis, admission to the intensive care unit (unadjusted odds ratio, 7.6 [CI, 1.2-48], P = 0.03), and the need for mechanical ventilation (unadjusted odds ratio 14 [CI, 1.3-159], P = 0.03) were associated with mortality. The six patients who previously had COVID-19 and subsequently received a LVAD were on intra-aortic balloon pump and inotropic support at time of surgery. All six experienced a complicated and prolonged postoperative course. Three patients (50%) suffered from ischemic stroke, and there was one (17%) 30 day mortality. We observed an increased risk of morbidity and mortality in LVAD patients with COVID-19.
Collapse
Affiliation(s)
- Jack Zakrzewski
- From the Department of Surgery, University of Colorado Anschutz Medical Campus, Aurora, Colorado
| | - Laura Coyle
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Tracy Aicher
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | | | - Colleen Gallagher
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Katelyn Kuper
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Chris Sciamanna
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Vinh Q. Chau
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Antone Tatooles
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| |
Collapse
|
25
|
Recommendations for Psychosocial Evaluation of VAD candidates: Adoption, completion, and barriers to implementation. Heart Lung 2021; 51:52-58. [PMID: 34731698 DOI: 10.1016/j.hrtlng.2021.10.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 10/12/2021] [Accepted: 10/17/2021] [Indexed: 11/20/2022]
Abstract
BACKGROUND Recommendations exist to guide clinicians on a comprehensive psychosocial (PS) evaluation prior to Mechanical Circulatory Support (MCS) implantation. OBJECTIVES Assess adoption, beliefs, methodologies, and barriers to completion of the 2018 ISHLT/APM/AST/ICCAC/STSW Recommendations for Psychosocial evaluation of adult cardiothoracic transplant and long term mechanical circulatory support. METHODS Cross-sectional survey distributed to all 183 implanting LVAD centers in North America via mail and email. RESULTS Total of 58 Programs (35.6% response rate) representing 29 states and all regions of the United States responded. Respondents reported implanting 1,183 adults (range 0 - 85; mean = 21.5, SD = 18) in 2018. A majority (n = 55, 94.8%) reported that the 2018 Recommendations were consistent with their clinical practice and most (n = 51, 87.9%) had adopted the recommendations. The Stanford Integrated Psychosocial Assessment for Transplant (SIPAT) (n = 25, 47.1%) was the most commonly cited assessment tool in the use, although 15 centers reported utilizing more than one tool during the assessment process. Most common barriers influencing completion of the PS evaluation include patient too ill (total responses = 104), lack of time (total responses = 89), patient poor candidate (total responses = 44), and lack of Insurance coverage/reimbursement (total responses = 41). CONCLUSION The 2018 ISHLT Recommendations for PS evaluation of LVAD Candidates are widely adopted by respondents in clinical practice, although barriers are still reported to their implementation. Additional research is needed to understand strategies to reduce barriers to implementation and maintenance of the recommendations in clinical practice.
Collapse
|
26
|
Cerebral Microvascular Injury in Patients with Left Ventricular Assist Device: a Neuropathological Study. Transl Stroke Res 2021; 13:257-264. [PMID: 34494179 DOI: 10.1007/s12975-021-00935-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 07/18/2021] [Accepted: 08/02/2021] [Indexed: 10/20/2022]
Abstract
Strokes are common among patients with left ventricular devices (LVAD). We hypothesize that there is ongoing cerebral microvascular injury with LVAD support and aim to describe this among LVAD-implanted patients through post-mortem neuropathologic evaluation. We identified and reviewed medical records of LVAD patients who underwent brain autopsy between January 2006 and December 2019 at a tertiary center. Cerebral injury was defined as both gross and microscopic injuries within the intracranial space including cerebral infarct (CI), hypoxic-ischemic brain injury (HIBI), intracranial hemorrhage (ICH), and cerebral microvascular injury. Cerebral microvascular injury was defined as microscopic brain intraparenchymal or perivascular hemorrhage, perivascular hemosiderin deposition, and perivascular inflammation. Twenty-one patients (median age = 57 years, 67% male) had autopsy after LVAD support (median LVAD support = 51 days). The median time from death to autopsy was 19 h. All 21 patients had cerebral injuries and 19 (90%) patients had cerebral microvascular injuries. Fourteen patients (78%) harbored more than one type of cerebral injury. On gross examination, 8 patients (38%) had CI, and 6 patients (29%) had ICH. On microscopic exam, 12 patients (57%) had microscopic intraparenchymal hemorrhage, 3 patients (14%) had perivascular hemorrhage, 11 patients (43%) had perivascular hemosiderin deposition, 5 patients (24%) had meningeal hemorrhage, 13 patients had chronic perivascular inflammation (62%), and 2 patients had diffuse HIBI (10%). Among patients with LVAD, there is a high prevalence of subclinical microvascular injuries and cerebral microbleeds (CMBs), which may provide some insights to the cause of frequent cerebral injury in LVAD population.
Collapse
|
27
|
To L, Attar D, Lines B, McCarty M, Nemeh H, Lopez-Plaza I, Smith Z, Coba V, Lekura J. Incidence of Heparin-Induced Thrombocytopenia in Patients With Newly Implanted Mechanical Circulatory Support Devices. Ann Pharmacother 2021; 56:565-571. [PMID: 34382428 DOI: 10.1177/10600280211038705] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Heparin exposure and device-related thrombocytopenia complicate the diagnosis of heparin-induced thrombocytopenia (HIT) in patients receiving mechanical circulatory support (MCS). To improve anticoagulation management for patients with newly implanted MCS devices, incidence of confirmed HIT needs to be further characterized. OBJECTIVES The purpose of this study is to describe the incidence of HIT and clinical utility of the 4Ts score in patients with newly implanted MCS devices. METHODS This is a retrospective analysis of MCS patients receiving unfractionated heparin from 2014 to 2017. The primary end point was incidence of laboratory-confirmed HIT. Strong positive, likely positive, low probability, and negative HIT categories were established based on heparin-induced platelet antibody (HIPA) and serotonin release assay (SRA). Secondary end points include characterization of platelet trends, argatroban use, incidence of HIT among each of the MCS devices, and utility of 4Ts score. RESULTS A total of 342 patient encounters met inclusion criteria, of which 68 HIPA tests and 25 SRAs were ordered. The incidence of HIT was 0.88% (3/342) and 4.4% (3/68) in patients with suspected HIT. Of the 68 HIPA tests, 3 (4.4%) were considered strong positive and 3 of the 25 SRAs were positive. Median 4Ts score was 4 [2.5-4] and optical density 0.19 [0.11-0.54]. The positive predictive value for the 4Ts score was 0.15 (CI = 0.03-0.46) and negative predictive value, 0.93 (CI = 0.82-0.98). CONCLUSION AND RELEVANCE HIT occurs infrequently with newly implanted MCS devices. The 4Ts score appears to have a high negative predictive value for ruling out HIT.
Collapse
Affiliation(s)
- Long To
- Henry Ford Hospital, Detroit, MI, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Liesdek OCD, Urbanus RT, de Heer LM, Fischer K, Suyker WJL, Schutgens REG. Alternatives for Vitamin K Antagonists as Thromboprophylaxis for Mechanical Heart Valves and Mechanical Circulatory Support Devices: A Systematic Review. Semin Thromb Hemost 2021; 47:724-734. [PMID: 34058767 DOI: 10.1055/s-0041-1722846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The holy grail of anticoagulation in patients with intracardiac devices, such as mechanical heart valves (MHVs) and left ventricular assist devices (LVADs), comprises safe prevention of thrombosis without interrupting normal hemostasis. Device-induced thrombosis and anticoagulant-related bleeding problems are dreaded complications that may cause a significantly reduced quality of life and increased morbidity and mortality. Vitamin K antagonists are the current standard for oral anticoagulation therapy in patients with MHVs and LVADs. Even within the therapeutic range, hemorrhage is the primary complication of these drugs, which emphasizes the need for safer anticoagulants for the prevention of device-induced thrombosis. Device-induced thrombosis is a complex multifactorial phenomenon that likely requires anticoagulant therapy targeting multiple pathways. Here, we review the preclinical and clinical data describing the efficacy of a variety of anticoagulants as thromboprophylaxis after implantation of intracardiac devices.
Collapse
Affiliation(s)
- Omayra C D Liesdek
- Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Rolf T Urbanus
- Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Linda M de Heer
- Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Kathelijn Fischer
- Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Willem J L Suyker
- Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Roger E G Schutgens
- Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
29
|
Boilson BA, Bechtum EL, Behnken AL, Loga LA, Luckhardt AJ, Schettle SD, Clavell AL, Dragomir-Daescu D, Stulak JM. Acoustic Properties of Axial and Centrifugal Flow Left Ventricular Assist Devices and Prediction of Pump Thrombosis. Mayo Clin Proc 2021; 96:887-900. [PMID: 33814091 DOI: 10.1016/j.mayocp.2020.10.043] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 09/11/2020] [Accepted: 10/06/2020] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To characterize the properties of the audible tones produced by current left ventricular assist device (LVAD) pumps approved for use, and to ascertain if changes in those may be present in the setting of pump thrombosis. PATIENTS AND METHODS From August 31, 2016, to January 16, 2020, LVAD recipients consented to have surface recordings obtained using a high-fidelity digital stethoscope. Audio data were analyzed using digital recording and editing software to produce an acoustic spectrogram by Fast Fourier transformation. RESULTS Recordings were obtained in 53 patient encounters (27 HeartMate II, 19 HeartWare and 7 HeartMate 3). In 12 patients (9 HeartMate II, 3 HeartWare) there was a clinical concern for pump thrombosis. In all patients and pump models, a fundamental frequency was noted, and the second and third harmonics were also clearly detectable. Where thrombosis occurred in the HeartMate II pump, the absolute (normal -46.9 [-57.5,-42.9] dB vs thrombosis -41.4 [-49.8,-26.8] dB; P=.08) and relative (normal 0.72 [0.62, 0.92] vs thrombosis 0.95 [0.86, 1.24]; P=.01) third harmonic frequencies were increased in amplitude. Where paired data were available, an increase in the absolute and relative third harmonic frequencies was observed in all patients. In the case of the HeartWare device, a consistent difference in harmonic amplitudes in the setting of thrombosis could not be identified. CONCLUSION A consistent pattern of fundamental and harmonic frequencies is common to all LVADs currently approved for use. Alterations in the amplitude of higher order harmonics may signal the onset of pump thrombosis in axial flow LVADs.
Collapse
Affiliation(s)
- Barry A Boilson
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN.
| | | | - Amy L Behnken
- Department of Cardiac Surgery, Mayo Clinic, Rochester, MN
| | - Laura A Loga
- Department of Cardiac Surgery, Mayo Clinic, Rochester, MN
| | | | | | | | - Dan Dragomir-Daescu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN
| | - John M Stulak
- Department of Cardiac Surgery, Mayo Clinic, Rochester, MN
| |
Collapse
|
30
|
Loyaga-Rendon RY, Kazui T, Acharya D. Antiplatelet and anticoagulation strategies for left ventricular assist devices. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:521. [PMID: 33850918 PMCID: PMC8039667 DOI: 10.21037/atm-20-4849] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Left ventricular assist devices (LVAD) have revolutionized the management of advanced heart failure. However, complications rates remain high, among which hemorrhagic and thrombotic complications are the most important. Antiplatelet and anticoagulation strategies form a cornerstone of LVAD management and may directly affect LVAD complications. Concurrently, LVAD complications influence anticoagulation and anticoagulation management. A thorough understanding of device, patient, and management, including anticoagulation and antiplatelet therapies, are important in optimizing LVAD outcomes. This article provides a comprehensive state of the art review of issues related to antiplatelet and anticoagulation management in LVADs. We start with a historical overview, the epidemiology and pathophysiology of bleeding and thrombotic complications in LVADs. We then discuss platelet and anticoagulation biology followed by considerations prior to, during, and after LVAD implantation. This is followed by discussion of anticoagulation and the management of thrombotic and hemorrhagic complications. Specific problems, including management of heparin-induced thrombocytopenia, anticoagulant reversal, novel oral anticoagulants, artificial heart valves, and noncardiac surgeries are covered in detail.
Collapse
Affiliation(s)
| | - Toshinobu Kazui
- Division of Cardiothoracic Surgery, University of Arizona, Tucson, AZ, USA
| | - Deepak Acharya
- Division of Cardiovascular Diseases, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
31
|
Dew MA, Hollenberger JC, Obregon LL, Hickey GW, Sciortino CM, Lockard KL, Kunz NM, Mathier MA, Ramani RN, Kilic A, McNamara DM, Simon MA, Keebler ME, Kormos RL. The Preimplantation Psychosocial Evaluation and Prediction of Clinical Outcomes During Mechanical Circulatory Support: What Information Is Most Prognostic? Transplantation 2021; 105:608-619. [PMID: 32345866 DOI: 10.1097/tp.0000000000003287] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Psychosocial evaluations are required for long-term mechanical circulatory support (MCS) candidates, no matter whether MCS will be destination therapy (DT) or a bridge to heart transplantation. Although guidelines specify psychosocial contraindications to MCS, there is no comprehensive examination of which psychosocial evaluation domains are most prognostic for clinical outcomes. We evaluated whether overall psychosocial risk, determined across all psychosocial domains, predicted outcomes, and which specific domains appeared responsible for any effects. METHODS A single-site retrospective analysis was performed for adults receiving MCS between April 2004 and December 2017. Using an established rating system, we coded psychosocial evaluations to identify patients at low, moderate, or high overall risk. We similarly determined risk within each of 10 individual psychosocial domains. Multivariable analyses evaluated whether psychosocial risk predicted clinical decisions about MCS use (DT versus bridge), and postimplantation mortality, transplantation, rehospitalization, MCS pump exchange, and standardly defined adverse medical events (AEs). RESULTS In 241 MCS recipients, greater overall psychosocial risk increased the likelihood of a DT decision (odds ratio, 1.76; P = 0.017); and postimplantation pump exchange and occurrence of AEs (hazard ratios [HRs] ≥ 1.25; P ≤ 0.042). The individual AEs most strongly predicted were cardiac arrhythmias and device malfunctions (HRs ≥ 1.39; P ≤ 0.032). The specific psychosocial domains predicting at least 1 study outcome were mental health problem severity, poorer medical adherence, and substance use (odds ratios and HRs ≥ 1.32; P ≤ 0.010). CONCLUSIONS The psychosocial evaluation predicts not only clinical decisions about MCS use (DT versus bridge) but important postimplantation outcomes. Strategies to address psychosocial risk factors before or soon after implantation may help to reduce postimplantation clinical risks.
Collapse
Affiliation(s)
- Mary Amanda Dew
- Department of Psychiatry, University of Pittsburgh, Pittsburgh, PA
- Department of Psychology, University of Pittsburgh, Pittsburgh, PA
- Department of Epidemiology, University of Pittsburgh, Pittsburgh, PA
- Department of Biostatistics, University of Pittsburgh, Pittsburgh, PA
- Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA
| | - Jennifer C Hollenberger
- Department of Social Work, Grove City College, Grove City, PA
- School of Social Work, Baylor University, Dallas, TX
| | - Laura L Obregon
- Health Care Policy and Management Program, Carnegie Mellon University, Pittsburgh, PA
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
| | - Gavin W Hickey
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Christopher M Sciortino
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA
| | - Kathleen L Lockard
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
| | - Nicole M Kunz
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
| | - Michael A Mathier
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Ravi N Ramani
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Arman Kilic
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA
| | - Dennis M McNamara
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Marc A Simon
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Mary E Keebler
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Medicine, University of Pittsburgh, Pittsburgh, PA
| | - Robert L Kormos
- Heart and Vascular Institute, University of Pittsburgh School of Medicine and Medical Center, Pittsburgh, PA
- Department of Surgery, University of Pittsburgh, Pittsburgh, PA
| |
Collapse
|
32
|
Pagani FD, Mehra MR, Cowger JA, Horstmanshof DA, Silvestry SC, Atluri P, Cleveland JC, Lindenfeld J, Roberts GJ, Bharmi R, Dalal N, Kormos RL, Rogers JG. Clinical outcomes and healthcare expenditures in the real world with left ventricular assist devices - The CLEAR-LVAD study. J Heart Lung Transplant 2021; 40:323-333. [PMID: 33744086 DOI: 10.1016/j.healun.2021.02.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 02/04/2021] [Accepted: 02/16/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Several distinctly engineered left ventricular assist devices (LVADs) are in clinical use. However, contemporaneous real world comparisons have not been conducted, and clinical trials were not powered to evaluate differential survival outcomes across devices. OBJECTIVES Determine real world survival outcomes and healthcare expenditures for commercially available durable LVADs. METHODS Using a retrospective observational cohort design, Medicare claims files were linked to manufacturer device registration data to identify de-novo, durable LVAD implants performed between January 2014 and December 2018, with follow-up through December 2019. Survival outcomes were compared using a Cox proportional hazards model stratified by LVAD type and validated using propensity score matching. Healthcare resource utilization was analyzed across device types by using nonparametric bootstrap analysis methodology. Primary outcome was survival at 1-year and total Part A Medicare payments. RESULTS A total of 4,195 de-novo LVAD implants were identified in fee-for-service Medicare beneficiaries (821 HeartMate 3; 1,840 HeartMate II; and 1,534 Other-VADs). The adjusted hazard ratio for mortality at 1-year (confirmed in a propensity score matched analysis) for the HeartMate 3 vs HeartMate II was 0.64 (95% CI; 0.52-0.79, p< 0.001) and for the HeartMate 3 vs Other-VADs was 0.51 (95% CI; 0.42-0.63, p < 0.001). The HeartMate 3 cohort experienced fewer hospitalizations per patient-year vs Other-VADs (respectively, 2.8 vs 3.2 EPPY hospitalizations, p < 0.01) and 6.1 fewer hospital days on average (respectively, 25.2 vs 31.3 days, p < 0.01). The difference in Medicare expenditures, conditional on survival, for HeartMate 3 vs HeartMate II was -$10,722, p < 0.001 (17.4% reduction) and for HeartMate 3 vs Other-VADs was -$17,947, p < 0.001 (26.1% reduction). CONCLUSIONS In this analysis of a large, real world, United States. administrative dataset of durable LVADs, we observed that the HeartMate 3 had superior survival, reduced healthcare resource use, and lower healthcare expenditure compared to other contemporary commercially available LVADs.
Collapse
Affiliation(s)
- Francis D Pagani
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
| | - Mandeep R Mehra
- Brigham and Women's Hospital Heart and Vascular Center and Harvard Medical School, Boston, Massachusetts
| | - Jennifer A Cowger
- Department of Cardiovascular Medicine, Henry Ford Hospitals, Detroit, Michigan
| | | | | | - Pavan Atluri
- Division of Cardiovascular Surgery, Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - JoAnn Lindenfeld
- Section of Heart Failure and Cardiac Transplantation, Vanderbilt University Medical Center, Nashville, Tennessee
| | | | | | | | | | - Joseph G Rogers
- Division of Cardiology, Duke University School of Medicine, Durham, North Carolina
| |
Collapse
|
33
|
Abstract
Mechanical blood-immersed bearings have been used in many continuous-flow rotary blood pumps to reduce friction between relatively moving parts, but their use has been associated with a significant incidence of pump thrombosis. As newer cardiac assist devices with more advanced bearings become available, the rate of pump thrombosis will likely decrease. Nevertheless, it is important to understand the design limitations of mechanical bearings as pumps utilizing them are still in use as chronic support devices and especially in the acute setting for temporary support devices. A properly designed journal bearing should support the spinning rotor with no surface-to-surface contact between the bearing and journal surfaces. The journal continuously undergoes orbital motion within the bearing, which can be "stable" or "unstable." Unstable orbital motion causes the journal to move progressively off-center until it collides with the bearing, and even minor variations in manufacturing can create off-design operation and dynamic instability of the journal. Since blood is the lubricant in most clinically-used rotary blood pumps, lubricant viscosity can vary abruptly in response to changes in hematocrit or plasma protein concentration. Additionally, shear stress from the high-speed rotor can cause hemolysis and plasma protein denaturation. We reviewed theoretical design and operating principles of mechanical bearings and discuss why the phenomenon of mechanical bearing thrombosis may be an inherent design issue dependent on variables that are beyond the control of clinicians.
Collapse
|
34
|
Abstract
Pump thrombosis (PT) is a serious adverse event in patients receiving left ventricular assist devices (LVAD). The study aims to determine whether pump parameters and clinical data may enable early detection of PT. This retrospective study included 88 patients who received an LVAD between 2012 and 2015 among which those with intra-PT were identified. In a propensity score-matched control group observation, time periods were matched with time before thrombosis. International normalized ratio (INR) time in therapeutic range (TTR) and lactate dehydrogenase (LDH) were analyzed for 60 days preceding PT. Furthermore, pump data (power, flow, and speed) in HeartWare ventricular assist devices (HVAD) patients were analyzed 7 days before PT using a mixed-design analysis of variance to investigate temporal changes in pump data. Pump thrombosis occurred in 15 patients (13 males, age 58 ± 10 years, 7 HeartMate II and 8 HVAD). International normalized ratio therapeutic range (2.0-3.0) and acetylsalicylic acid daily doses (100-200 mg) were similar for both groups, but patients with PT had lower TTR (36% vs. 65%; p = 0.025). No significant difference in LVAD power between groups was seen at baseline (p = 0.31), and power did not change in the control group over time (p > 0.99). Lactate dehydrogenase increased already 1 week prior PT and power from 4.4 ± 0.8 W at baseline to 4.9 ± 0.8 W (p = 0.007) 2 days before readmission and to 6.5 ± 1.8 W (p = 0.015) at readmission. Pump thrombosis is associated with a lower percentage of INR TTR and elevated LDH before the event. A better monitoring of pump parameters would enable PT detection already up to 2 days in advance.
Collapse
|
35
|
Dimitrov K, Maier J, Sandner S, Riebandt J, Wiedemann D, Moayedifar R, Schlöglhofer T, Angleitner P, Niederdöckl J, Schima H, Tschernko E, Laufer G, Zimpfer D. Thrombolysis as first-line therapy for Medtronic/HeartWare HVAD left ventricular assist device thrombosis. Eur J Cardiothorac Surg 2020; 58:1182-1191. [DOI: 10.1093/ejcts/ezaa180] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 04/21/2020] [Accepted: 04/25/2020] [Indexed: 11/12/2022] Open
Abstract
Abstract
OBJECTIVES
We reviewed our institutional experience with intravenous thrombolysis (TL) as first-line therapy in patients with Medtronic/HeartWare HVAD left ventricular assist device pump thrombosis (PT).
METHODS
From March 2006 to November 2018, 30 Medtronic/HeartWare HVAD left ventricular assist device patients had 48 PT events. We analysed outcomes with intravenous Alteplase as a first-line therapy for PT. Pump exchange or urgent heart transplantation was only considered after the failure of TL or existing contraindications to TL.
RESULTS
TL was used as the first-line therapy in 44 PT events in 28 patients without a contraindication to TL. TL was successful in 61.4% of PT events. More than 1 cycle of TL was necessary in 55.6% of events. The combined success of TL and heart transplantation or device exchange was 81.8%. In 15.9% of events, PT was fatal. Causes of death were severe complications (9.1%) related to TL or discontinuation of therapy for multi-organ failure (6.8%). Intracranial bleeding and arterial thromboembolism were observed in 4.5% and 11.5% of the PT events after TL.
CONCLUSIONS
Intravenous TL as a first-line therapy for PT in Medtronic/HeartWare HVAD patients can be a reasonable treatment option and does not preclude subsequent heart transplantation or device exchange. However, thromboembolic and bleeding complications are common. The decision to perform TL or device exchange should, therefore, be made on an individual basis after balancing the risks and benefits of different treatment approaches.
Collapse
Affiliation(s)
- Kamen Dimitrov
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Julian Maier
- Institute of Pharmacology, Center for Physiology and Pharmacology, Medical University of Vienna, Vienna, Austria
| | - Sigrid Sandner
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Julia Riebandt
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Dominik Wiedemann
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Roxana Moayedifar
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Schlöglhofer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria
| | - Philipp Angleitner
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Jan Niederdöckl
- Department of Emergency Medicine, Medical University of Vienna, Vienna, Austria
| | - Heinrich Schima
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
- Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria
| | - Edda Tschernko
- Department of Anaesthesia, Division of Cardiothoracic and Vascular Anaesthesia and Intensive Care Medicine, Medical University of Vienna, Vienna, Austria
| | - Guenther Laufer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
36
|
Kormos RL, Antonides CF, Goldstein DJ, Cowger JA, Starling RC, Kirklin JK, Rame JE, Rosenthal D, Mooney ML, Caliskan K, Messe SR, Teuteberg JJ, Mohacsi P, Slaughter MS, Potapov EV, Rao V, Schima H, Stehlik J, Joseph S, Koenig SC, Pagani FD. Updated definitions of adverse events for trials and registries of mechanical circulatory support: A consensus statement of the mechanical circulatory support academic research consortium. J Heart Lung Transplant 2020; 39:735-750. [DOI: 10.1016/j.healun.2020.03.010] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 03/02/2020] [Accepted: 03/16/2020] [Indexed: 11/30/2022] Open
|
37
|
Left Ventricular Assist Device Exchange Increases Heart Transplant Wait-List Mortality. J Surg Res 2020; 255:277-284. [PMID: 32570131 DOI: 10.1016/j.jss.2020.05.062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Revised: 04/02/2020] [Accepted: 05/03/2020] [Indexed: 12/26/2022]
Abstract
BACKGROUND The new heart transplant allocation criteria prioritize inpatients who require temporary mechanical circulatory support and give lower urgency to candidates on a durable left ventricular assist device (LVAD) who require a device exchange. This study explores whether the latter group should warrant higher priority to reduce wait-list mortality. METHODS This is a retrospective observational study of 13,113 adult heart transplant candidates in the Organ Procurement and Transplantation Network database who underwent LVAD implantation between 2007 and 2017. It evaluates the impact of LVAD exchange on the composite endpoint of death or removal from the wait list owing to worsening medical condition 1 y after device implantation. RESULTS There were 1085 pump exchanges in 954 patients (7% of candidates), of which 22% were women. The pump exchange rate was 5.92 events per 100 patient-years. One-year survival was lower for those who required a pump exchange (76.3% versus 88.5%, logrank P < 0.001). This was congruent with the risk-adjusted mortality 1-y after implantation (hazards ratio: 2.56, 95% confidence interval: 2.18-3.00, P < 0.001). CONCLUSIONS These findings indicate that among candidates awaiting heart transplantation with a durable LVAD, undergoing pump exchange doubles the risk of 1-y mortality. Giving priority to these candidates may reduce wait-list mortality.
Collapse
|
38
|
Mondal S, Sankova S, Lee K, Sorensen E, Kaczorowski D, Mazzeffi M. Intraoperative and Early Postoperative Management of Patients Undergoing Minimally Invasive Left Ventricular Assist Device Implantation. J Cardiothorac Vasc Anesth 2020; 35:616-630. [PMID: 32505605 DOI: 10.1053/j.jvca.2020.04.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 04/03/2020] [Accepted: 04/09/2020] [Indexed: 11/11/2022]
Affiliation(s)
- Samhati Mondal
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Susan Sankova
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Khang Lee
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD
| | - Erik Sorensen
- Department of Surgery, Division of Cardiothoracic Surgery, University of Maryland School of Medicine, Baltimore, MD
| | - David Kaczorowski
- Department of Surgery, Division of Cardiothoracic Surgery, University of Maryland School of Medicine, Baltimore, MD
| | - Michael Mazzeffi
- Department of Anesthesiology, University of Maryland School of Medicine, Baltimore, MD.
| |
Collapse
|
39
|
Seese L, Hickey G, Keebler M, Thoma F, Kilic A. Limited Efficacy of Thrombolytics for Pump Thrombosis in Durable Left Ventricular Assist Devices. Ann Thorac Surg 2020; 110:2047-2054. [PMID: 32348739 DOI: 10.1016/j.athoracsur.2020.03.061] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 02/20/2020] [Accepted: 03/23/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND This study reports a single-center experience with thrombolytics for left ventricular assist device (LVAD) pump thrombosis. METHODS Adults undergoing continuous-flow LVAD implantation between 2004 and 2018 at a single center were reviewed and those with pump thrombosis were identified. Primary outcomes included 1-year survival and success rates of thrombolytic therapy. Secondary outcomes included posttreatment adverse events, freedom from major bleeding at 1 year, and freedom from stroke at 1-year follow-up. RESULTS A total of 341 patients underwent LVAD implantation and 10.8% (n = 37) developed pump thrombosis. Of those 37, 26 received initial thrombolytic therapy (70.2%), 5 underwent direct pump exchange (13.5%), and 6 received only intravenous heparin owing to presentation with acute stroke or severe multiorgan failure (16.2%). Successful treatment was achieved in 11.5% of patients receiving thrombolytics (n = 3). Early adverse events after thrombolytic therapy included major bleeding in 11.5% (n = 3) and new stroke in 7.7% (n = 2). Most patients undergoing thrombolytic therapy underwent subsequent device exchange (69.2%; n = 18). Overall survival in patients with pump thrombosis after treatment was 96.8% at 30 days, 78.9% at 90 days, and 63.1% at 1 year. Freedom from major bleeding and stroke at 1 year was 74.2% and 87.2%, respectively. CONCLUSIONS In this single-center experience of thrombolytics for pump thrombosis in LVAD patients, there was limited efficacy; most patients required subsequent pump exchange. Combined with the risk for major bleeding or stroke with thrombolysis, this underscores the importance of further refining patient selection for direct pump exchange in those presenting with pump thrombosis.
Collapse
Affiliation(s)
- Laura Seese
- Division of Cardiac Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Gavin Hickey
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Division of Cardiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Mary Keebler
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Division of Cardiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Floyd Thoma
- Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania
| | - Arman Kilic
- Division of Cardiac Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
| |
Collapse
|
40
|
Imamura T, Narang N, Kim G, Raikhelkar J, Chung B, Nguyen A, Holzhauser L, Rodgers D, Kalantari S, Smith B, Ota T, Song T, Juricek C, Burkhoff D, Jeevanandam V, Sayer G, Uriel N. Decoupling Between Diastolic Pulmonary Artery and Pulmonary Capillary Wedge Pressures Is Associated With Right Ventricular Dysfunction and Hemocompatibility-Related Adverse Events in Patients With Left Ventricular Assist Devices. J Am Heart Assoc 2020; 9:e014801. [PMID: 32223394 PMCID: PMC7428624 DOI: 10.1161/jaha.119.014801] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Background Decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure is an index of pulmonary vascular damage. This study assessed the impact of decoupling on right heart function and hemocompatibility‐related adverse events. Methods and Results In this prospective study, patients underwent invasive hemodynamic tests following left ventricular assist device implantation. Decoupling was defined as a difference of >5 mm Hg between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. Among 92 patients with left ventricular assist devices (median age, 61 years; 57% male), 44 patients (48%) had decoupling. Right heart function and size by echocardiographic assessment worsened during a 1‐year observational period in the decoupling group as compared with the control group (P<0.05). The decoupling group had significantly lower 1‐year freedom from any hemocompatibility‐related adverse events (49% versus 79%; P=0.005), as well as a higher hemocompatibility score (2.14 versus 0.67; P=0.004). The scoring system depicts the severity of hemocompatibility‐related adverse events using 4 escalating tiers. Increased tier I scores (1–2 gastrointestinal bleedings or medically managed pump thrombosis; P=0.027) and tier IIIB scores (disabling stroke or hemocompatibility‐related adverse event–related death; P=0.041) occurred more frequently in the decoupling group. Conclusions The presence of decoupling between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure was associated with worsening of right heart function and hemocompatibility‐related adverse events in patients with left ventricular assist devices.
Collapse
Affiliation(s)
- Teruhiko Imamura
- Department of Medicine University of Chicago Medical Center Chicago IL.,Second Department of Medicine University of Toyama Toyama Japan
| | - Nikhil Narang
- Advocate Heart Institute Advocate Christ Medical Center Oak Lawn IL
| | - Gene Kim
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Jayant Raikhelkar
- Division of Cardiology Columbia University Medical Center New York NY
| | - Ben Chung
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Ann Nguyen
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Luise Holzhauser
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Daniel Rodgers
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Sara Kalantari
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Bryan Smith
- Department of Medicine University of Chicago Medical Center Chicago IL
| | - Takeyoshi Ota
- Department of Surgery University of Chicago Medical Center Chicago IL
| | - Tae Song
- Department of Surgery University of Chicago Medical Center Chicago IL
| | - Colleen Juricek
- Department of Surgery University of Chicago Medical Center Chicago IL
| | - Daniel Burkhoff
- Division of Cardiology Columbia University Medical Center New York NY
| | | | - Gabriel Sayer
- Division of Cardiology Columbia University Medical Center New York NY
| | - Nir Uriel
- Division of Cardiology Columbia University Medical Center New York NY
| |
Collapse
|
41
|
Outcomes Associated with Obesity in Patients Undergoing Left Ventricular Assist Device Implantation: A Systematic Review and Meta-Analysis. ASAIO J 2020; 66:401-408. [DOI: 10.1097/mat.0000000000001019] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
42
|
Kirklin JK, Pagani FD, Goldstein DJ, John R, Rogers JG, Atluri P, Arabia FA, Cheung A, Holman W, Hoopes C, Jeevanandam V, John R, Jorde UP, Milano CA, Moazami N, Naka Y, Netuka I, Pagani FD, Pamboukian SV, Pinney S, Rogers JG, Selzman CH, Silverstry S, Slaughter M, Stulak J, Teuteberg J, Vierecke J, Schueler S, D'Alessandro DA. American Association for Thoracic Surgery/International Society for Heart and Lung Transplantation guidelines on selected topics in mechanical circulatory support. J Thorac Cardiovasc Surg 2020; 159:865-896. [DOI: 10.1016/j.jtcvs.2019.12.021] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
43
|
|
44
|
Kirklin JK, Pagani FD, Goldstein DJ, John R, Rogers JG, Atluri P, Arabia FA, Cheung A, Holman W, Hoopes C, Jeevanandam V, John R, Jorde UP, Milano CA, Moazami N, Naka Y, Netuka I, Pagani FD, Pamboukian SV, Pinney S, Rogers JG, Selzman CH, Silverstry S, Slaughter M, Stulak J, Teuteberg J, Vierecke J, Schueler S, D'Alessandro DA. American Association for Thoracic Surgery/International Society for Heart and Lung Transplantation guidelines on selected topics in mechanical circulatory support. J Heart Lung Transplant 2020; 39:187-219. [PMID: 31983666 DOI: 10.1016/j.healun.2020.01.1329] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Affiliation(s)
| | - James K Kirklin
- Department of Surgery, University of Alabama at Birmingham, Birmingham, Ala.
| | | | - Daniel J Goldstein
- Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY
| | | | | | | | | | | | - Anson Cheung
- University of British Columbia, Vancouver, British Columbia, Canada
| | - William Holman
- Department of Surgery, University of Alabama at Birmingham, Birmingham, Ala
| | - Charles Hoopes
- Department of Surgery, University of Alabama at Birmingham, Birmingham, Ala
| | | | | | - Ulrich P Jorde
- Montefiore Medical Center/Albert Einstein College of Medicine, Bronx, NY
| | | | - Nader Moazami
- Langone Medical Center, New York University, New York, NY
| | - Yoshifumi Naka
- Columbia University College of Physicians & Surgeons, New York, NY
| | - Ivan Netuka
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | | - Salpy V Pamboukian
- Department of Surgery, University of Alabama at Birmingham, Birmingham, Ala
| | | | | | | | | | | | - John Stulak
- Mayo Clinic College of Medicine and Science, Rochester, Minn
| | | | | | | | - Stephan Schueler
- Department for Cardiothoracic Surgery, Newcastle upon Tyne Freeman Hospital, Newcastle upon Tyne, United Kingdom
| | - David A D'Alessandro
- Department of Cardiothoracic Surgery, Massachusetts General Hospital, Boston, Mass
| |
Collapse
|
45
|
Imamura T, Narang N, Rodgers D, Nguyen A, Ota T, Song T, Kim G, Raikhelkar J, Jeevanandam V, Sayer G, Uriel N. Outcomes following left ventricular assist device exchange. J Card Surg 2020; 35:591-597. [PMID: 31945223 DOI: 10.1111/jocs.14423] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Left ventricular assist device (LVAD) exchange has been historically associated with a significant risk of morbidity and mortality. It is unknown, however, whether these outcomes have improved. We aimed to compare clinical outcomes following LVAD exchange to those following initial LVAD implant in a contemporary patient cohort. METHODS A total of 115 LVAD patients were enrolled between 2014 and 2017 and followed for 1 year. Of these, 15 patients (54.5 ± 13.3 years old, 87% male) underwent LVAD exchange at 277 (IQR 191-597) days following LVAD implantation and 100 patients (57.5 ± 12.3 years old, 76% male) did not undergo an LVAD exchange (non-exchange group). RESULTS One-year survival rate following LVAD exchange tended to be higher than the non-exchange patients (93% vs 76%, P = .15). Readmission rates for each comorbidity did not significantly differ between the two groups (P > .05 for all) except for the higher rate of pump thrombosis in the LVAD exchange group (P < .05). DISCUSSION LVAD exchange cohorts seem to have comparable clinical outcome with the non-exchange cohorts. CONCLUSION LVAD exchange might be an increasingly appropriate therapeutic option for the management of pump thrombosis, although careful monitoring for recurrent pump thrombosis is required.
Collapse
Affiliation(s)
- Teruhiko Imamura
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.,Second Department of Medicine, University of Toyama, Toyama, Japan
| | - Nikhil Narang
- Advocate Heart Institute, Advocate Christ Medical Center, Oak Lawn, Illinois
| | - Daniel Rodgers
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Ann Nguyen
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Takeyoshi Ota
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Tae Song
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Gene Kim
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Jayant Raikhelkar
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | | | - Gabriel Sayer
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Nir Uriel
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| |
Collapse
|
46
|
Imamura T, Nitta D, Fujino T, Smith B, Kalantari S, Nguyen A, Narang N, Holzhauser L, Rodgers D, Song T, Ota T, Jeevanandam V, Kim G, Sayer G, Uriel N. Deep Y-Descent in Right Atrial Waveforms Following Left Ventricular Assist Device Implantation. J Card Fail 2020; 26:360-367. [PMID: 31935459 DOI: 10.1016/j.cardfail.2020.01.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 09/17/2019] [Accepted: 01/02/2020] [Indexed: 01/16/2023]
Abstract
BACKGROUND Characterization of right heart catheterization (RHC) waveforms provides diagnostic and clinical information in heart failure patients. We aimed to investigate the implication of RHC waveforms, specifically the y-descent, in patients with left ventricular assist device (LVAD). METHODS AND RESULTS Patients underwent RHC and waveforms were quantified prior to and 6 months after LVAD implantation. The impact of a deep y-descent (>3 mmHg) on echocardiographic measures of right heart function and 1-year hemocompatibility-related adverse event rates were investigated. Eighty-nine patients (median 59 years old, 65 male) underwent RHC. RHC waveform showed unique changes following LVAD implantation, particularly an increase in the steepness of the y-descent. A post-LVAD deep y-descent was associated with reduced right ventricular function and enlarged right heart. Patients with post-LVAD deep y-descent had higher rates of gastrointestinal bleeding (0.866 vs 0.191 events/year) and stroke (0.199 vs 0 events/year) compared with those without (P< .05 for both). CONCLUSION RHC waveforms characterized by deep y-descent on RHC waveform during LVAD support was associated with impaired right ventricular function and worse clinical outcomes.
Collapse
Affiliation(s)
- Teruhiko Imamura
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
| | - Daisuke Nitta
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Takeo Fujino
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Bryan Smith
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Sara Kalantari
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Ann Nguyen
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Nikhil Narang
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Luise Holzhauser
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Daniel Rodgers
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Tae Song
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Takeyoshi Ota
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | | | - Gene Kim
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Gabriel Sayer
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Nir Uriel
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| |
Collapse
|
47
|
Bouzas-Cruz N, Gonzalez-Fernandez O, Ferrera-Durán C, Woods A, Robinson-Smith N, Tovey S, Jungschleger J, Booth K, Shah A, Parry G, MacGowan GA, Schueler S. Initial conservative management strategy of HeartWare left ventricular assist device thrombosis with intravenous heparin or bivalirudin. Int J Artif Organs 2019; 43:444-451. [DOI: 10.1177/0391398819896585] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Introduction and objectives: Pump thrombosis is a serious left ventricular assist device complication, though there are no guidelines regarding its treatment. The main aim of this study was to describe a strategy of intravenous anticoagulation as the initial treatment in these patients and then to compare intravenous heparin with bivalirudin. Methods: All consecutive patients who received a HeartWare left ventricular assist device from July 2009 to March 2019 were retrospectively analysed. Patients developing a pump thrombosis were selected, and treatment, outcomes and complications were recorded. Results: During this period of time (116 months), 220 patients underwent HeartWare left ventricular assist device implantation and 57 developed pump thrombosis, with an incidence rate of first pump thrombosis of 0.17 events per patient-year of support (incidence rate of all episodes of pump thrombosis: 0.30 events per patient-year of support). All the patients were initially treated medically, predominantly with either intravenous heparin (n = 26) or bivalirudin (n = 16). Patients treated with bivalirudin during the first pump thrombosis episode had less subsequent re-thrombosis episodes (18.7% vs 57.7%, p < 0.05). In addition, percentage time in therapeutic range was greater for bivalirudin compared with heparin (68.5% ± 16.9% vs 37.4% ± 31.0%, p < 0.01). During the first pump thrombosis episode, 26.3% of the patients needed surgery (left ventricular assist device exchange (n = 8), transplant (n = 6) or decommissioning (n = 1)). The overall survival at 1 year was 61.4%, and there was no significant difference in survival. Conclusion: Left ventricular assist device thrombosis is a serious life-threatening complication; hence, we propose an initial conservative management of pump thrombosis with enhanced intravenous anticoagulation with either intravenous heparin or bivalirudin, with surgery reserved for refractory cases.
Collapse
Affiliation(s)
- Noelia Bouzas-Cruz
- Department of Cardiology, Freeman Hospital, Newcastle Upon Tyne, UK
- University of Santiago de Compostela, Santiago, Spain
| | | | - Carlos Ferrera-Durán
- Department of Cardiology, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiology, Hospital Clínico San Carlos, Madrid, Spain
| | - Andrew Woods
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
| | | | - Sian Tovey
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Jérôme Jungschleger
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Karen Booth
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Asif Shah
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Gareth Parry
- Department of Cardiology, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Guy A MacGowan
- Department of Cardiology, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
- Institute of Genetic Medicine, Newcastle University, Newcastle upon Tyne, UK
| | - Stephan Schueler
- Department of Cardiothoracic Surgery, Freeman Hospital, Newcastle Upon Tyne, UK
- Department of Cardiothoracic Transplantation, Freeman Hospital, Newcastle Upon Tyne, UK
| |
Collapse
|
48
|
Li M, Walk R, Roka-Moiia Y, Sheriff J, Bluestein D, Barth EJ, Slepian MJ. Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution. Artif Organs 2019; 44:E226-E237. [PMID: 31876310 DOI: 10.1111/aor.13626] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/20/2019] [Accepted: 12/16/2019] [Indexed: 12/28/2022]
Abstract
Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing the device under development and testing are utilized as a means of assessing device thrombogenicity. Physical characteristics of these test circulatory loops may also contribute to inadvertent platelet activation through imparted shear stress, adding inadvertent error in evaluating MCS device thrombogenicity. While investigators normally control for the effect of a loop, inadvertent addition of what are considered innocuous connectors may impact test results. Here, we tested the effect of common, additive components of in vitro circulatory test loops, that is, connectors and loop geometry, as to their additive contribution to shear stress via both in silico and in vitro models. A series of test circulatory loops containing a ventricular assist device (VAD) with differing constituent components, were established in silico including: loops with 0~5 Luer connectors, a loop with a T-connector creating 90° angulation, and a loop with 90° angulation. Computational fluid dynamics (CFD) simulations were performed using a k - ω shear stress transport turbulence model to platelet activation index (PAI) based on a power law model. VAD-operated loops replicating in silico designs were assembled in vitro and gel-filtered human platelets were recirculated within (1 hour) and SMPA was determined. CFD simulations demonstrated high shear being introduced at non-smooth regions such as edge-connector boundaries, tubing, and at Luer holes. Noticeable peaks' shifts of scalar shear stress (sss) distributions toward high shear-region existed with increasing loop complexity. Platelet activation also increased with increasing shear exposure time, being statistically higher when platelets were exposed to connector-employed loop designs. The extent of platelet activation in vitro could be successfully predicted by CFD simulations. Loops employing additional components (non-physiological flow pattern connectors) resulted in higher PAI. Loops with more components (5-connector loop and 90° T-connector) showed 63% and 128% higher platelet activation levels, respectively, versus those with fewer (0-connector (P = .023) and a 90° heat-bend loop (P = .0041). Our results underscore the importance of careful consideration of all component elements, and suggest the need for standardization in designing in vitro circulatory loops for MCS device evaluation to avoid inadvertent additive SMPA during device evaluation, confounding overall results. Specifically, we caution on the use and inadvertent introduction of additional connectors, ports, and other shear-generating elements which introduce artifact, clouding primary device evaluation via introduction of additive SMPA.
Collapse
Affiliation(s)
- Mengtang Li
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Ryan Walk
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - Yana Roka-Moiia
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Eric J Barth
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Marvin J Slepian
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA.,Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.,Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
49
|
Imamura T, Narang N, Nnanabu J, Rodgers D, Raikhelkar J, Kalantari S, Smith B, Nguyen A, Chung B, Ota T, Song T, Jeevanandam V, Kim G, Sayer G, Uriel N. Hemodynamics of concomitant tricuspid valve procedures at LVAD implantation. J Card Surg 2019; 34:1511-1518. [PMID: 31693250 DOI: 10.1111/jocs.14275] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Tricuspid regurgitation (TR) is common in patients receiving left ventricular assist device (LVAD) implantation. The current literature is conflicting regarding the effects of concomitant tricuspid valve repair (TVR) at LVAD implantation. We investigated the hemodynamic effects of concomitant TVR at LVAD implantation. METHODS Consecutive clinically stable LVAD outpatients who underwent hemodynamic ramp testings were enrolled in this study, and they were stratified by concomitant TVR. Results of hemodynamic ramp tests were compared between the TVR group and the non-TVR group. RESULTS Among 65 LVAD patients undergoing ramp tests, 34 patients had received TVR, and 31 had not. There were no significant differences in baseline characteristics between two groups except for higher degree of TR and lower pulmonary artery pulsatility index in the TVR group (P < .05 for both). Following LVAD implantation, the degree of TR improved significantly in the TVR group down to the comparable level with the non-TVR group. During ramp tests, the TVR group had steeper cardiac index slope (0.14 ± 0.12 vs 0.07 ± 0.07 L/min/m2 /step, P = .002) and higher cardiac index at set LVAD speed (2.99 ± 0.84 vs 2.52 ± 0.42 L/min/m2 , P = .007). CONCLUSIONS Concomitant TVR improves cardiac output and its response to LVAD speed change following LVAD implantation. Longitudinal clinical implications of such hemodynamic changes are unknown.
Collapse
Affiliation(s)
- Teruhiko Imamura
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Nikhil Narang
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Jerry Nnanabu
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Daniel Rodgers
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Jayant Raikhelkar
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Sara Kalantari
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Bryan Smith
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Ann Nguyen
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Ben Chung
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Takeyoshi Ota
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | - Tae Song
- Department of Surgery, University of Chicago Medical Center, Chicago, Illinois
| | | | - Gene Kim
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Gabriel Sayer
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Nir Uriel
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| |
Collapse
|
50
|
Urban M, Um J, Moulton M, Stoller D, Zolty R, Lowes B, Macdonald C, McCain N, Siddique A. Recurrent pump thrombosis is common after axial continuous-flow left ventricular assist device exchange. Int J Artif Organs 2019; 43:109-118. [PMID: 31530254 DOI: 10.1177/0391398819876293] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
In selected patients with left ventricular assist device-associated infection or malfunction, pump exchange may become necessary after conservative treatment options fail and heart transplantation is not readily available. We examined the survival and complication rate in patients (⩾19 years of age) who underwent HeartMate II to HeartMate II exchange at our institution from 1 January 2010 to 28 February 2018. Clinical outcomes were analyzed and compared for patients who underwent exchange for pump thrombosis (14 patients), breach of driveline integrity (5 patients), and device-associated infection (2 patients). There were no differences in 30-day mortality (p = 0.58), need for temporary renal replacement therapy (p = 0.58), right ventricular mechanical support (p = 0.11), and postoperative stroke (p = 0.80) among groups. Survival at 1 year was 90% ± 7% for the whole cohort and 85% ± 10% for those who underwent exchange for pump thrombosis. In patients exchanged for device thrombosis, freedom from re-thrombosis and survival free from pump re-thrombosis at 1 year were 49% ± 16% and 42% ± 15%, respectively. No association of demographic and clinical variables with the risk of recurrent pump thrombosis after the first exchange was identified. Survival after left ventricular assist device exchange compares well with published results after primary left ventricular assist device implantation. However, recurrence of thrombosis was common among patients who required a left ventricular assist device exchange due to pump thrombosis. In this sub-group, consideration should be given to alternative strategies to improve the outcomes.
Collapse
Affiliation(s)
- Marian Urban
- University of Nebraska Medical Center, Omaha, NE, USA
| | - John Um
- University of Nebraska Medical Center, Omaha, NE, USA
| | | | | | - Ronald Zolty
- University of Nebraska Medical Center, Omaha, NE, USA
| | - Brian Lowes
- University of Nebraska Medical Center, Omaha, NE, USA
| | | | | | | |
Collapse
|