1
|
Werner J, Zgoła-Grześkowiak A, Grześkowiak T. Development of novel thin-film solid-phase microextraction materials based on deep eutectic solvents for preconcentration of trace amounts of parabens in surface waters. J Sep Sci 2022; 45:1374-1384. [PMID: 35137554 DOI: 10.1002/jssc.202100917] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 01/16/2022] [Accepted: 01/31/2022] [Indexed: 11/09/2022]
Abstract
A green and sensitive thin-film solid-phase microextraction method based on deep eutectic solvent was developed that enables simultaneous isolation, preconcentration, and determination of parabens in surface waters. Six new deep eutectic solvents were synthesized and used directly to prepare thin-film coatings on a stainless steel mesh support. Among the compounds obtained, the highest efficiency in the extraction of parabens was found for a material consisting of trihexyltetradecylphosphonium chloride and n-docosanol in a molar ratio of 1:2. For the proposed method, parameters affecting the extraction efficiency of parabens, such as the coating material, the desorption solvent, the volume of the sample, the pH of the sample, the extraction and desorption time, and the salting-out effect, were optimized. Under optimal conditions, the proposed method allowed us to achieve good precision between 3.6 and 6.5% and recovery ranging from 68.1 to 91.4%. The limits of detection range from 0.018 to 0.055 ng mL-1 . This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Justyna Werner
- Poznan University of Technology, Faculty of Chemical Technology, Poland
| | | | | |
Collapse
|
2
|
Wojtkiewicz J, Tzatzarakis M, Vakonaki E, Makowska K, Gonkowski S. Evaluation of human exposure to parabens in north eastern Poland through hair sample analysis. Sci Rep 2021; 11:23673. [PMID: 34880378 PMCID: PMC8654909 DOI: 10.1038/s41598-021-03152-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 11/24/2021] [Indexed: 12/02/2022] Open
Abstract
Parabens (PBs) are a group of substances commonly used in industry. They also pollute the environment, penetrate into living organisms and adversely affect various internal organs. During this study, the degree of exposure of people living in Olsztyn, a city in north eastern Poland, to selected parabens most often used in industry was studied. The chemicals under investigation included: methyl paraben—MePB, ethyl paraben—EtPB, propyl paraben—PrPB, benzyl paraben BePB and butyl paraben -BuPB. To this aim, hair samples collected from the scalps of 30 volunteers were analyzed using a liquid chromatography–mass spectrometry technique. All PBs studied were present in a high percentage of analyzed samples (from 76.7% in the case of BePB to 100% in the case of MePB and PrPB). The mean concentration levels were 4425.3 pg/mg for MeBP, 704.0 pg/mg for EtPB, 825.7 pg/mg for PrPB, 135.2 pg/mg for BePB and 154.5 pg/mg for BuPB. Significant differences in PB concentration levels between particular persons were visible. On the other hand, gender, age and artificial hair coloring did not cause statistically significant differences in PB levels. Obtained results have clearly indicated that people living in north eastern Poland are exposed to various PBs, and therefore these substances may affect their health status. However, the evaluation of PBs influence on human health requires further research.
Collapse
Affiliation(s)
- Joanna Wojtkiewicz
- Department of Pathophysiology, School of Medicine, Collegium Medicum, University of Warmia and Mazury, 10-900, Olsztyn, Poland.
| | - Manolis Tzatzarakis
- Laboratory of Toxicology Science and Research, Medicine School, University of Crete, 70013, Heraklion, Crete, Greece
| | - Elena Vakonaki
- Laboratory of Toxicology Science and Research, Medicine School, University of Crete, 70013, Heraklion, Crete, Greece
| | - Krystyna Makowska
- Department of Clinical Diagnostics, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 14, 10-957, Olsztyn, Poland
| | - Slawomir Gonkowski
- Department of Clinical Physiology, Faculty of Veterinary Medicine, University of Warmia and Mazury in Olsztyn, Oczapowskiego 13, 10-957, Olsztyn, Poland
| |
Collapse
|
3
|
Andersen MHG, Zuri G, Knudsen LE, Mathiesen L. Placental transport of parabens studied using an ex-vivo human perfusion model. Placenta 2021; 115:121-128. [PMID: 34601208 DOI: 10.1016/j.placenta.2021.09.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 08/16/2021] [Accepted: 09/02/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Parabens are a group of chemicals widely used as preservatives in daily consumer products such as cosmetics, food items, pharmaceuticals and household commodities. They have been broadly detected in human samples indicating a general human exposure, and concerns arose from their potential endocrine disrupting effect. Especially the exposure to parabens during pregnancy is concerning, as the time of fetal development is a particularly vulnerable period. The aim of this study was to investigate the transport and metabolism of four commonly used parabens: methyl-, ethyl-, propyl- and butylparaben (MeP, EtP, PrP and BuP) and the metabolite para-hydroxybenzoic acid (PHBA) across the human placenta. METHODS An ex-vivo human placental perfusion model was used. The test compounds were added in the maternal compartment (with initial concentrations of 1 mM or 0.1 mM). Placental transport was evaluated by fetal-maternal concentration ratios (FM-ratio), transport index (TI) and indicative permeability (IP). RESULTS Information about parabens kinetics was taken from 10 perfusions and PHBA from 7 perfusions. Paraben metabolism was not detected. The placental transport of MeP, EtP, PrP, BuP and PHBA revealed a transfer from maternal to fetal circulations with FM120 of 0.86 ± 0.27 (MeP), 0.98 ± 0.28 (EtP), 1.00 ± 0.28 (PrP), 1.12 ± 0.59 (BuP) and 0.82 ± 0.37 (PHBA). The test substances accumulated in the perfused tissue in some degree. The average kinetic parameters FM-ratio, TI and IP were not different between chemicals. DISCUSSION The present study shows that the placenta barrier is permeable to all four parabens and the metabolite, which implies potential fetal exposure.
Collapse
Affiliation(s)
- Maria Helena Guerra Andersen
- Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014, Copenhagen K, Denmark; The National Research Centre for the Working Environment, Lersø Parkalle 105, DK-1014, Copenhagen Ø, Denmark
| | - Giuseppina Zuri
- Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014, Copenhagen K, Denmark
| | - Lisbeth E Knudsen
- Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014, Copenhagen K, Denmark
| | - Line Mathiesen
- Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014, Copenhagen K, Denmark.
| |
Collapse
|
4
|
Tran TM, Tran-Lam TT, Mai HHT, Bach LHT, Nguyen HMN, Trinh HT, Dang LT, Minh TB, Quan TC, Hoang AQ. Parabens in personal care products and indoor dust from Hanoi, Vietnam: Temporal trends, emission sources, and non-dietary exposure through dust ingestion. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 761:143274. [PMID: 33183808 DOI: 10.1016/j.scitotenv.2020.143274] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 10/06/2020] [Accepted: 10/20/2020] [Indexed: 06/11/2023]
Abstract
The occurrence of seven typical parabens was investigated in several types of personal care products (PCPs) sold at supermarkets and in indoor dust samples collected from houses, laboratories, and medical stores in Hanoi, Vietnam. Parabens were frequently detected in PCPs regardless of the paraben indication in their ingredient labels. However, concentrations of parabens in labeled products (median 3280; range 1370-5610 μg/g) were much higher than those found in non-labeled products (69.4; not detected - 356 μg/g). Parabens were also measured in indoor dust samples of this study at elevated concentrations, ranging from not detected to 1650 (median 286 ng/g). Levels of parabens in the indoor dust samples collected in 2019 decreased in the order: house > medical store > laboratory dust, however, the difference was not statistically significant. Interestingly, levels of parabens in Vietnamese house dust exhibited an increasing trend over time, for example, mean/median concentrations of parabens in house dust samples collected in 2014, 2017, and 2019 were 245/205, 310/264, and 505/379 ng/g, respectively. Methylparaben was found at the highest frequency and concentrations in both PCPs and indoor dust samples. Mean exposure doses of total parabens through dust ingestion were estimated to be 2.02, 1.61, 0.968, 0.504, and 0.192 ng/kg-bw/d for infants, toddlers, children, teenagers, and adults, respectively. Further studies on the distribution, emission behavior, potential sources, and negative impacts of parabens in different environmental media in Vietnam are needed.
Collapse
Affiliation(s)
- Tri Manh Tran
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam.
| | - Thanh-Thien Tran-Lam
- Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Hanoi 10000, Viet Nam
| | - Hang Hong Thi Mai
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam
| | - Lan Hong Thi Bach
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam
| | - Ha My Nu Nguyen
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam; Ha Tinh University, Cam Vinh Commune, Cam Xuyen District, Ha Tinh 45000, Viet Nam
| | - Hue Thi Trinh
- Institute of Theoretical and Applied Research, Duy Tan University, Hanoi 10000, Viet Nam; Faculty of Environmental and Chemical Engineering, Duy Tan University, Da Nang 50000, Viet Nam
| | - Lieu Thi Dang
- Center for Research and Technology Transfer, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Hanoi 10000, Viet Nam
| | - Tu Binh Minh
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam
| | - Thuy Cam Quan
- Viet Tri University of Industry (VUI), Viet Tri, Phu Tho 35000, Viet Nam
| | - Anh Quoc Hoang
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Viet Nam; Center of Advanced Technology for the Environment (CATE), Graduate School of Agriculture, Ehime University, 3-5-7 Tarumi, Matsuyama 790-8566, Japan
| |
Collapse
|
5
|
WEI J, QIN M, YANG J, YANG L. [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction]. Se Pu 2021; 39:219-228. [PMID: 34227304 PMCID: PMC9403807 DOI: 10.3724/sp.j.1123.2020.04024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Indexed: 11/30/2022] Open
Abstract
Microextraction is a rapidly developing sample preparation technology in the field of analytical chemistry, which is seeing widespread application. Accurate sample preparation can not only save time but also improve the efficiency of analysis, determination, and data quality. At present, sample pretreatment methods must be rapid, allow for miniaturization, automation, and convenient online connection with analytical instruments. To meet the requirements of green analytical methods and improve the extraction efficiency, microextraction techniques have been introduced as suitable replacements to conventional sample preparation and extraction methods. Microextraction using a packed sorbent (MEPS) is a new type of sample preparation technology. The MEPS equipment was prepared using microsyringe with a volume of 50-500 μL, including MEPS syringes and MEPS adsorption beds (barrel insert and needle, BIN), which is essentially similar to a miniaturized solid phase extraction device. The BIN contains the adsorbent and is built into the syringe needle. A typical MEPS extraction procedure involves repeatedly pumping the sample solution in two directions (up and down) through the adsorbent multiple times in the MEPS syringe. The specific operation course of MEPS includes conditioning, loading, washing, elution, and introduction into the analysis instrument. The conditioning process is adopted to infiltrate the dry sorbent and remove bubbles between the filler particles. The adsorption process is accomplished by pulling the liquid plunger of the syringe so that the sample flows through the adsorbent in both directions multiple times. The washing process involves rinsing the sorbent to remove unwanted components after the analyte is retained. The elution process involves the use of an eluent to ensure that the sample flows through the adsorbent in both directions multiple times, so that elution can be realized by the pumping-pushing action. The target analyte is eluted with the eluent, which can be directly used for chromatographic analysis. However, when processing complex biological matrix samples by MEPS, pretreatment steps such as dilution of the sample and removal of proteins are commonly required. At present, the operation modes of the MEPS equipment are classified into three types: manual, semi-automated, and fully automated. This increase in the degree of automation is highly conducive to processing extremely low or extremely high sample volumes. Critical factors affecting the MEPS performance have been investigated in this study. The conditions for MEPS optimization are the operating process parameters, including sample flow rate, sample volume, number of sample extraction cycles, type and volume of the adsorbent, and elution solvents. It is also necessary to consider the effect of the sample matrix on the performance of MEPS. The MEPS sorbent should be cleaned by a solvent to eliminate carryover and reuse. The sorbent is a core aspect of MEPS. Several types of commercial and non-commercial sorbents have been used in MEPS. Commercial sorbents include silica-based sorbents such as unmodified silica (SIL), C2, C8, and C18. Unmodified silicon-based silica is a normal phase adsorption material, which is highly polar and can be used to retain polar analytes. C18, C8, and C2 materials are suitable for reversed-phase adsorption, while SCX, SAX, APS, and M1 (C8+SCX) adsorbents are suitable for the mixed-mode and ion-exchange modes. Noncommercial sorbents include molecularly imprinted materials, restricted-access molecularly imprinted materials, graphitized carbon, conductive polymer materials, modified silicon materials, and covalent-organic framework materials. The performance of MEPS has recently been illustrated by online with LC-MS and GC-MS assays for the analysis of biological matrices, environmental samples, and food samples. Pretreatment in MEPS protocols includes dilution, protein precipitation, and centrifugation in biological fluid matrices. Because of the small sample size, fast operation, etc., MEPS is expected to be more widely used in the analysis of bio-matrix samples. MEPS devices could also play an important role in field pretreatment and analysis.
Collapse
Affiliation(s)
- Jianan WEI
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Molin QIN
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Junchao YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Liu YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| |
Collapse
|
6
|
Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector. Pharmaceuticals (Basel) 2020; 13:ph13110412. [PMID: 33266462 PMCID: PMC7700590 DOI: 10.3390/ph13110412] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 11/19/2020] [Accepted: 11/20/2020] [Indexed: 11/25/2022] Open
Abstract
Isothiazolinones methylisothiazolinone (MI) and methylchloroisothiazolinone (MCI), and parabens methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) are the most common synthetic preservatives. They are all known to be potential skin allergens that lead to contact dermatitis. Thus, the identification of these unsafe chemicals in cosmetic products is of high importance. In the present study, solid-phase extraction (SPE) based on HyperSep reversed-phase C8/benzene sulfonic acid ion exchanger (HyperSep C8/BSAIE) and Sep-Pak C18 sorbents, and ultra-high performance liquid chromatography/diode array detector (UHPLC/DAD) were optimized for the simultaneous determination of MI, MCI, MP, EP, PP and BP in cosmetic products. HyperSep C8/BSAIE and UHPLC/DAD with the eluting solvent mixture (acetonitrile/methanol, 2:1, v/v) and detection wavelength (255 nm) were found to be the optimal conditions, respectively. The method illustrates the excellent linearity range (0.008–20 μg/mL) with coefficient of determination (R2, 0.997–0.999), limits of detection (LOD, 0.001–0.002 μg/mL), precision in terms of relative standard deviation (RSD < 3%, intra-day and <6%, inter-day) when examining a standard mixture at low (0.07 µg/mL), medium (3 µg/mL) and high (15 µg/mL) concentrations. A total of 31 cosmetic samples were studied, achieving concentrations (MI, not detected (nd)-0.89 µg/g), (MCI, nd-0.62 µg/g), (MP, nd-6.53 µg/g), (EP, nd-0.90 µg/g), (PP, nd-9.69 µg/g) and (BP, nd-17.80 µg/g). Recovery values ranged from 92.33 to 101.43% depending on the types of sample. To our knowledge, this is the first specific method which covers the theme and describes background amounts of such preservatives in cosmetics.
Collapse
|
7
|
Rigkos G, Alampanos V, Kabir A, Furton KG, Roje Ž, Vrček IV, Panderi I, Samanidou V. An improved fabric‐phase sorptive extraction protocol for the determination of seven parabens in human urine by HPLC–DAD. Biomed Chromatogr 2020; 35:e4974. [DOI: 10.1002/bmc.4974] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 08/14/2020] [Accepted: 08/21/2020] [Indexed: 12/19/2022]
Affiliation(s)
- Georgios Rigkos
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| | - Vasileios Alampanos
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry Florida International University Miami FL USA
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry Florida International University Miami FL USA
| | - Željka Roje
- Department for Plastic, Reconstructive and Aesthetic Surgery University Hospital Dubrava Zagreb Croatia
| | | | - Irene Panderi
- Laboratory of Pharmaceutical Analysis, Division of Pharmaceutical Chemistry, Faculty of Pharmacy National and Kapodistrtian University of Athens Panepistimiopolis‐Zografou Athens GR Greece
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| |
Collapse
|
8
|
Sanchis Y, Coscollà C, Corpas-Burgos F, Vento M, Gormaz M, Yusà V. Biomonitoring of bisphenols A, F, S and parabens in urine of breastfeeding mothers: Exposure and risk assessment. ENVIRONMENTAL RESEARCH 2020; 185:109481. [PMID: 32278926 DOI: 10.1016/j.envres.2020.109481] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 02/28/2020] [Accepted: 04/01/2020] [Indexed: 06/11/2023]
Abstract
In the present study we used human biomonitoring to assess the internal exposure and the risk to four parabens and three bisphenols in 103 Spanish breastfeeding mothers participating in the BETTERMIILK project. Urinary methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP) presented detection frequencies ranging from 12% (BP) to 92% (MP), while bisphenol A (BPA), bisphenol F (BPF) and bisphenol S (BPS) were detected in 76% (BPA) and 20% (BPF, BPS) of the mothers. Average paraben concentrations (geometric mean) ranged from 0.021 ng mL-1 (BP) to 17.7 ng mL-1 (MP), whereas bisphenols had geometric means concentrations from 0.042 ng mL-1 (BPF) to 0.927 ng mL-1 (BPA). Except for BPA, the estimated daily intakes (EDI) were calculated in order to interpret urinary levels in a risk assessment context. The obtained EDIs ranged from 0.00042 mg/kg/day for PP to 0.0434 mg/kg/day for MP and EP. A hazard quotient (HQ) was calculated for BPA (0.0049) and parabens (0.001-0.004), showing no risk in the studied population. Sociodemographic characteristics, food consumption, and usage patterns of personal care products (PCPs) were investigated as possible determinants of exposure. Use of makeup and skincare products were associated with higher concentrations of MP and PP, respectively. Regarding dietary habits, MP was also associated with the consumption of packaged and bakery products.
Collapse
Affiliation(s)
- Yovana Sanchis
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain; Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020, Valencia, Spain
| | - Clara Coscollà
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain; Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020, Valencia, Spain
| | - Francisca Corpas-Burgos
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain
| | - Máximo Vento
- Neonatal Division at the University and Polytechnic Hospital La Fe, Avenida Abril Martorell, 106, 46026, Valencia, Spain
| | - María Gormaz
- Neonatal Division at the University and Polytechnic Hospital La Fe, Avenida Abril Martorell, 106, 46026, Valencia, Spain
| | - Vicent Yusà
- Foundation for the Promotion of Health and Biomedical Research in the Valencian Region, FISABIO-Public Health, 21, Avenida Catalunya, 46020, Valencia, Spain; Public Health Laboratory of Valencia, 21, Avenida Catalunya, 46020, Valencia, Spain; Analytical Chemistry Department, University of Valencia, Edifici Jeroni Muñoz, Dr. Moliner 50, 46100, Burjassot, Spain.
| |
Collapse
|
9
|
Silveira RS, Rocha BA, Rodrigues JL, Barbosa F. Rapid, sensitive and simultaneous determination of 16 endocrine-disrupting chemicals (parabens, benzophenones, bisphenols, and triclocarban) in human urine based on microextraction by packed sorbent combined with liquid chromatography tandem mass spectrometry (MEPS-LC-MS/MS). CHEMOSPHERE 2020; 240:124951. [PMID: 31574445 DOI: 10.1016/j.chemosphere.2019.124951] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 08/14/2019] [Accepted: 09/23/2019] [Indexed: 06/10/2023]
Abstract
A high demand exists in human biomonitoring studies for reliable and straightforward methods that generate data faster and simultaneously. Thus, the present study combines microextraction by packed sorbent (MEPS) and liquid chromatography coupled to mass spectrometry (LC-MS/MS) for simultaneous extraction and determination of various classes of endocrine-disrupting chemicals (EDCs), including parabens, benzophenones, bisphenols, and the antimicrobial, triclocarban in human urine samples. Optimized MEPS conditions were: i) MEPS sorbent (C18), ii) pH of sample (3), iii) volume of sample (250 μL), iv) number of draws-eject cycles (5) and (vi) desorption solvent conditions (100 μL of CH3OH:H2O 80:20 v/v). The calibration curves were linear over the selected ranges for all studied compound, with correlation coefficients higher than 0.99. The variation coefficient for precision was lower than 20% at lower concentrations and lower than 15% at the higher concentrations studied. The accuracy ranged from 90% to 118%. The proposed strategy affords several advantages over currently published approaches, including simplicity of operation and reduction of sample and solvent volumes and time for matrix clean-up. Moreover, the analytical performance of each MEPS cartridge remained stable over the analysis of at least 70 samples (RSD < 10%). Thus, the current procedure may be an interesting high-throughput alternative for large routine human biomonitoring studies. Urinary geometric mean concentrations of EDCs obtained in this study were close than those previously reported for Brazilian children.
Collapse
Affiliation(s)
- Romena Sanglard Silveira
- Laboratório de Toxicologia e Essencialidade de Metais, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14049-903, Ribeirão Preto, SP, Brazil
| | - Bruno Alves Rocha
- Laboratório de Toxicologia e Essencialidade de Metais, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14049-903, Ribeirão Preto, SP, Brazil; Instituto de Ciências Ambientais, Químicas e Farmacêuticas, Universidade Federal de São Paulo, Rua Prof. Artur Riedel, 275, Diadema, SP, 09972-270, Brazil
| | - Jairo Lisboa Rodrigues
- Laboratório Multiusuário, Instituto de Ciência, Engenharia e Tecnologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Teófilo Otoni, MG, 39803-371, Brazil
| | - Fernando Barbosa
- Laboratório de Toxicologia e Essencialidade de Metais, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14049-903, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
10
|
Martins I, Lambert M, Pereira AFS, de Faria HD, de Lima EC, Pereira GR. Serum analysis in women and in vitro skin assay for the assessment of exposure to parabens in antiperspirants. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:4219-4226. [PMID: 31828701 DOI: 10.1007/s11356-019-07038-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 11/11/2019] [Indexed: 06/10/2023]
Abstract
The present study assessed the exposure to methylparaben (MP) and propylparaben (PP) from antiperspirants in serum of 24 women aged 20-30 years old and an in vitro skin assay. An effective liquid chromatography-tandem mass spectrometry method for the determination of MP and PP levels in serum was developed and validated in the range of 10-100 μg/L; the method was fast, simple, sensitive, linear, precise, and accurate. In addition, a simple and rapid liquid chromatography-ultraviolet detection method for the determination of MP and PP levels in antiperspirants was developed and validated in the range of 2-26 mg/L, which presented satisfactory linearity, precision, and accuracy. Using these two methods, 20 commercial antiperspirants were evaluated, and only three showed MP and PP in the formulation. The antiperspirant containing 0.2% and 0.1% w/w MP and PP, respectively, was given to the volunteers, to estimate the internal dose, and submitted to a pig ear skin permeation assay in Franz diffusion cells, presenting a permeation flux of 32% for MP and 71% for PP. In this assay, both MP and PP permeated the skin; however, there was no correlation between antiperspirant use and paraben serum concentration in the volunteers. Graphical abstract.
Collapse
Affiliation(s)
- Isarita Martins
- Laboratory of Toxicants and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Gabriel Monteiro Street, 700, Alfenas, 37130-000, Brazil.
| | - Mayara Lambert
- Laboratory of Toxicants and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Gabriel Monteiro Street, 700, Alfenas, 37130-000, Brazil
| | - Ana Flávia Souza Pereira
- Laboratory of Toxicants and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Gabriel Monteiro Street, 700, Alfenas, 37130-000, Brazil
| | - Henrique Dipe de Faria
- Laboratory of Toxicants and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Gabriel Monteiro Street, 700, Alfenas, 37130-000, Brazil
| | | | - Gislaine Ribeiro Pereira
- Laboratory of Liberation Systems, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, Brazil
| |
Collapse
|
11
|
Martín J, Santos JL, Aparicio I, Alonso E. Exposure assessment to parabens, bisphenol A and perfluoroalkyl compounds in children, women and men by hair analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 695:133864. [PMID: 31421338 DOI: 10.1016/j.scitotenv.2019.133864] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 08/08/2019] [Accepted: 08/08/2019] [Indexed: 05/28/2023]
Abstract
Population is continuously exposed to endocrine disrupting compounds present in everyday products such as parabens, bisphenol A (BPA), and perfluoroalkyl compounds (PFCs). The aims of this study were, first, to evaluate human exposure to three parabens (methylparaben (MeP), ethylparaben (EtP) and propylparaben (PrP)), BPA and six PFCs (perfluorobutanoic acid, perfluoropentanoic acid, perfluorohexanoic acid, perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS)) through the analysis of hair samples from children, women and men and, then, to evaluate possible relationships between pollutant concentration in hair and age, gender, smoking and dyeing habits or hair colour. Hair samples were collected from 42 volunteers from Seville (Spain) (10 children, 16 women and 16 men). Six of the monitored pollutants (MeP, EtP, PrP, BPA, PFHpA and PFOS) were detected in at least 76% of the samples analysed. The highest concentrations and frequency of detection (100% of the samples) corresponded to MeP and PrP (up to 14,187 and 9009 ng/g, respectively). BPA was found in 83% of the samples at concentrations in the range from 24 to 1427 ng/g whereas PFCs were detected at concentrations in the range from 0.6 to 15.5 ng/g, being PFHpA and PFOS the ones most frequently detected (86% and 76%, respectively). Concentrations of BPA and parabens in adults were statistically higher than those in children. The results of this study reveal the suitability of hair for biomonitoring endocrine disrupting compounds of high concern (PFCs, parabens and BPA) to which population is internally or/and externally but continuously exposed.
Collapse
Affiliation(s)
- Julia Martín
- Departmento de Química Analítica, Escuela Politécnica Superior, Universidad de Sevilla, C/ Virgen de África, 7, E-41011 Sevilla, Spain.
| | - Juan Luis Santos
- Departmento de Química Analítica, Escuela Politécnica Superior, Universidad de Sevilla, C/ Virgen de África, 7, E-41011 Sevilla, Spain
| | - Irene Aparicio
- Departmento de Química Analítica, Escuela Politécnica Superior, Universidad de Sevilla, C/ Virgen de África, 7, E-41011 Sevilla, Spain
| | - Esteban Alonso
- Departmento de Química Analítica, Escuela Politécnica Superior, Universidad de Sevilla, C/ Virgen de África, 7, E-41011 Sevilla, Spain
| |
Collapse
|
12
|
Sanchis Y, Coscollà C, Yusà V. Analysis of four parabens and bisphenols A, F, S in urine, using dilute and shoot and liquid chromatography coupled to mass spectrometry. Talanta 2019; 202:42-50. [DOI: 10.1016/j.talanta.2019.04.048] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 04/15/2019] [Accepted: 04/18/2019] [Indexed: 12/11/2022]
|
13
|
Pereira JAM, Gonçalves J, Porto-Figueira P, Figueira JA, Alves V, Perestrelo R, Medina S, Câmara JS. Current trends on microextraction by packed sorbent – fundamentals, application fields, innovative improvements and future applications. Analyst 2019; 144:5048-5074. [DOI: 10.1039/c8an02464b] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
MEPS, the acronym of microextraction by packed sorbent, is a simple, fast and user- and environmentally-friendly miniaturization of the popular solid-phase extraction technique (SPE).
Collapse
Affiliation(s)
- Jorge A. M. Pereira
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - João Gonçalves
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | | | - José A. Figueira
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Vera Alves
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Rosa Perestrelo
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - Sonia Medina
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
| | - José S. Câmara
- CQM – Centro de Química da Madeira
- Universidade da Madeira
- 9020-105 Funchal
- Portugal
- Faculdade de Ciências Exatas e da Engenharia
| |
Collapse
|
14
|
Recent development of chromatographic methods to determine parabens in breast milk samples: A review. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1093-1094:82-90. [DOI: 10.1016/j.jchromb.2018.06.059] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 04/10/2018] [Accepted: 06/30/2018] [Indexed: 12/27/2022]
|
15
|
Magnetic carbon nanotube composite for the preconcentration of parabens from water and urine samples using dispersive solid phase extraction. J Chromatogr A 2018; 1564:102-109. [DOI: 10.1016/j.chroma.2018.06.025] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 06/07/2018] [Accepted: 06/09/2018] [Indexed: 11/18/2022]
|
16
|
Makkliang F, Kanatharana P, Thavarungkul P, Thammakhet-Buranachai C. A miniaturized monolith-MWCNTs-COOH multi-stir-rod microextractor device for trace parabens determination in cosmetic and personal care products. Talanta 2018; 184:429-436. [DOI: 10.1016/j.talanta.2018.03.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 03/08/2018] [Accepted: 03/10/2018] [Indexed: 11/30/2022]
|
17
|
Farajzadeh MA, Bakhshizadeh Aghdam M, Afshar Mogaddam MR, Alizadeh Nabil AA. Simultaneous derivatization and lighter-than-water air-assisted liquid-liquid microextraction using a homemade device for the extraction and preconcentration of some parabens in different samples. J Sep Sci 2018; 41:3105-3112. [PMID: 29873179 DOI: 10.1002/jssc.201701022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 05/07/2018] [Accepted: 05/24/2018] [Indexed: 01/30/2023]
Abstract
Simultaneous derivatization and air-assisted liquid-liquid microextraction using an organic that is solvent lighter than water has been developed for the extraction of some parabens in different samples with the aid of a newly designed device for collecting the extractant. For this purpose, the sample solution is transferred into a glass test tube and a few microliters of acetic anhydride (as a derivatization agent) and p-xylene (as an extraction solvent) are added to the solution. After performing the procedure, the homemade device consists of an inverse funnel with a capillary tube placed into the tube. In this step, the collected extraction solvent and a part of the aqueous solution are transferred into the device and the organic phase indwells in the capillary tube of the device. Under the optimal conditions, limits of detection and quantification for the analytes were obtained in the ranges of 0.90-2.7 and 3.0-6.1 ng/mL, respectively. The enrichment and enhancement factors were in the ranges of 370-430 and 489-660, respectively. The method precision, expressed as the relative standard deviation, was within the range of 4-6% (n = 6) and 4-9% (n = 4) for intra- and interday precisions, respectively. The proposed method was successfully used for the determination of methyl-, ethyl-, and propyl parabens in cosmetic, hygiene and food samples, and personal care products.
Collapse
Affiliation(s)
- Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.,Engineering Faculty, Near East University, Nicosia, North Cyprus, Mersin, Turkey
| | | | - Mohammad Reza Afshar Mogaddam
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.,Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | | |
Collapse
|
18
|
Raza N, Kim KH, Abdullah M, Raza W, Brown RJ. Recent developments in analytical quantitation approaches for parabens in human-associated samples. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.11.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
19
|
A fast bioanalytical method based on microextraction by packed sorbent and UPLC–MS/MS for determining new psychoactive substances in oral fluid. Talanta 2017; 174:454-461. [DOI: 10.1016/j.talanta.2017.06.022] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 06/08/2017] [Accepted: 06/09/2017] [Indexed: 11/23/2022]
|
20
|
Shen X, Liang J, Zheng L, Lv Q, Wang H. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography. J Sep Sci 2017; 40:4385-4393. [PMID: 28877408 DOI: 10.1002/jssc.201700722] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Revised: 08/28/2017] [Accepted: 08/30/2017] [Indexed: 12/28/2022]
Affiliation(s)
- Xiong Shen
- Department of Pharmacy; Zhongshan Hospital, Fudan University; Shanghai P.R. China
| | - Jian Liang
- Department of Pharmacy; Zhongshan Hospital, Fudan University; Shanghai P.R. China
| | - Luxia Zheng
- Shanghai Institute for Food and Drug Control; Shanghai P.R. China
| | - Qianzhou Lv
- Department of Pharmacy; Zhongshan Hospital, Fudan University; Shanghai P.R. China
| | - Hong Wang
- Department of General Surgery; Zhongshan Hospital, Fudan University; Shanghai P.R. China
| |
Collapse
|
21
|
Klimowska A, Wielgomas B. Off-line microextraction by packed sorbent combined with on solid support derivatization and GC-MS: Application for the analysis of five pyrethroid metabolites in urine samples. Talanta 2017; 176:165-171. [PMID: 28917736 DOI: 10.1016/j.talanta.2017.08.011] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 08/01/2017] [Accepted: 08/02/2017] [Indexed: 10/19/2022]
Abstract
A novel, fast and eco-friendly analytical method using microextraction by packed sorbent coupled to large volume injection-gas chromatography-mass spectrometry (MEPS-LVI-GC-MS) was developed for the determination of five pyrethroid metabolites (cis-2,2-dimethyl-3-(2-chloro-3,3,3-trifluoro-1-propenyl)-cyclopropanecarboxylic acid, cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acids, cis-(2,2-dibromovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid and 3-phenoxybenzoic acid) in human urine. MEPS was performed off-line using a manually-operated semiautomatic syringe (eVol), and several parameters including the sample pH, extraction sorbent, washing solvent, volume and type of elution solvent and number of draw-eject cycles were optimized. Analytes were extracted from enzymatically hydrolyzed urine using a C18 solid phase with subsequent simultaneous derivatization and elution with a mixture of 1,1,1,3,3,3-hexafluoroisopropanol and diisopropylcarbodiimide in n-hexane (on-line derivatization). The optimized method was validated, with linearity established from 0.05 to 25ngmL-1 and R values > 0.99. Obtained quantification limits were in the range of 0.06-0.08ngmL-1, and the precision expressed as relative standard deviation (RSD) was below 14% for all of the analytes. The method was cross-validated with a reference approach based on liquid-liquid extraction-gas chromatography-mass spectrometry (LLE-GC-MS) by analyzing 21 urine samples.
Collapse
Affiliation(s)
- Anna Klimowska
- Department of Toxicology, Medical University of Gdańsk, Al. Gen. Hallera 107, 80-416 Gdańsk, Poland.
| | - Bartosz Wielgomas
- Department of Toxicology, Medical University of Gdańsk, Al. Gen. Hallera 107, 80-416 Gdańsk, Poland.
| |
Collapse
|
22
|
Pinto MAL, de Souza ID, Queiroz MEC. Determination of drugs in plasma samples by disposable pipette extraction with C18-BSA phase and liquid chromatography–tandem mass spectrometry. J Pharm Biomed Anal 2017; 139:116-124. [DOI: 10.1016/j.jpba.2017.02.052] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 02/24/2017] [Accepted: 02/28/2017] [Indexed: 11/16/2022]
|
23
|
Fumes BH, Lanças FM. Use of graphene supported on aminopropyl silica for microextraction of parabens from water samples. J Chromatogr A 2017; 1487:64-71. [DOI: 10.1016/j.chroma.2017.01.063] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 01/23/2017] [Accepted: 01/24/2017] [Indexed: 12/31/2022]
|
24
|
Rosado T, Fernandes L, Barroso M, Gallardo E. Sensitive determination of THC and main metabolites in human plasma by means of microextraction in packed sorbent and gas chromatography–tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1043:63-73. [DOI: 10.1016/j.jchromb.2016.09.007] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Revised: 09/01/2016] [Accepted: 09/05/2016] [Indexed: 11/26/2022]
|
25
|
Casas Ferreira AM, Moreno Cordero B, Pérez Pavón JL. Use of microextraction by packed sorbent directly coupled to an electron ionization single quadrupole mass spectrometer as an alternative for non-separative determinations. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1043:74-80. [DOI: 10.1016/j.jchromb.2016.07.052] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 07/21/2016] [Accepted: 07/29/2016] [Indexed: 11/16/2022]
|
26
|
Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples. Anal Chim Acta 2016; 932:49-59. [DOI: 10.1016/j.aca.2016.05.027] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Revised: 05/06/2016] [Accepted: 05/20/2016] [Indexed: 11/19/2022]
|
27
|
Electrochemical degradation of butyl paraben on platinum and glassy carbon electrodes. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.03.016] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|