Riehakainen L, Mota-Silva E, Kusmic C, Panetta D, Petroni D, Fragnito D, Salvadori S, Menichetti L. Assessment of tissue response in vivo: PET-CT imaging of titanium and biodegradable magnesium implants. Acta Biomater 2024; 184:461-472. [PMID: 38871201 DOI: 10.1016/j.actbio.2024.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 06/01/2024] [Accepted: 06/06/2024] [Indexed: 06/15/2024]
Abstract
To study in vivo the bioactivity of biodegradable magnesium implants and other possible biomaterials, we are proposing a previously unexplored application of PET-CT imaging, using available tracers to follow soft tissue and bone remodelling and immune response in the presence of orthopaedic implants. Female Wistar rats received either implants (Ti6Al7Nb titanium or WE43 magnesium) or corresponding transcortical sham defects into the diaphyseal area of the femurs. Inflammatory response was followed with [18F]FDG and osteogenesis with [18F]NaF, over the period of 1.5 months after surgery. An additional pilot study with [68Ga]NODAGA-RGD tracer specific to αvβ3 integrin expression was performed to follow the angiogenesis for one month. [18F]FDG tracer uptake peaked on day 3 before declining in all groups, with Mg and Ti groups exhibiting overall higher uptake compared to sham. This suggests increased cellular activity and tissue response in the presence of Mg during the initial weeks, with Ti showing a subsequent increase in tracer uptake on day 45, indicating a foreign body reaction. [18F]NaF uptake demonstrated the superior osteogenic potential of Mg compared to Ti, with peak uptake on day 7 for all groups. [68Ga]NODAGA-RGD pilot study revealed differences in tracer uptake trends between groups, particularly the prolonged expression of αvβ3 integrin in the presence of implants. Based on the observed differences in the uptake trends of radiotracers depending on implant material, we suggest that PET-CT is a suitable modality for long-term in vivo assessment of orthopaedic biomaterial biocompatibility and underlying tissue reactions. STATEMENT OF SIGNIFICANCE: The study explores the novel use of positron emission tomography for the assessment of the influence that biomaterials have on the surrounding tissues. Previous related studies have mostly focused on material-related effects such as implant-associated infections or to follow the osseointegration in prosthetics, but the use of PET to evaluate the materials has not been reported before. The approach tests the feasibility of using repeated PET-CT imaging to follow the tissue response over time, potentially improving the methodology for adopting new biomaterials for clinical use.
Collapse
Affiliation(s)
- Leon Riehakainen
- The Sant'Anna School of Advanced Studies, Pisa, Italy; Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy.
| | - Eduarda Mota-Silva
- The Sant'Anna School of Advanced Studies, Pisa, Italy; Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Claudia Kusmic
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Daniele Panetta
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Debora Petroni
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Davide Fragnito
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Stefano Salvadori
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| | - Luca Menichetti
- Institute of Clinical Physiology, National Research Council (IFC-CNR), Pisa, Italy
| |
Collapse
|
2
|
Giavaresi G, Bellavia D, De Luca A, Costa V, Raimondi L, Cordaro A, Sartori M, Terrando S, Toscano A, Pignatti G, Fini M. Magnesium Alloys in Orthopedics: A Systematic Review on Approaches, Coatings and Strategies to Improve Biocompatibility, Osteogenic Properties and Osteointegration Capabilities. Int J Mol Sci 2023; 25:282. [PMID: 38203453 PMCID: PMC10778661 DOI: 10.3390/ijms25010282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/19/2023] [Accepted: 12/22/2023] [Indexed: 01/12/2024] Open
Abstract
There is increasing interest in using magnesium (Mg) alloy orthopedic devices because of their mechanical properties and bioresorption potential. Concerns related to their rapid degradation have been issued by developing biodegradable micro- and nanostructured coatings to enhance corrosion resistance and limit the release of hydrogen during degradation. This systematic review based on four databases (PubMed®, Embase, Web of Science™ and ScienceDirect®) aims to present state-of-the-art strategies, approaches and materials used to address the critical factors currently impeding the utilization of Mg alloy devices. Forty studies were selected according to PRISMA guidelines and specific PECO criteria. Risk of bias assessment was conducted using OHAT and SYRCLE tools for in vitro and in vivo studies, respectively. Despite limitations associated with identified bias, the review provides a comprehensive analysis of preclinical in vitro and in vivo studies focused on manufacturing and application of Mg alloys in orthopedics. This attests to the continuous evolution of research related to Mg alloy modifications (e.g., AZ91, LAE442 and WE43) and micro- and nanocoatings (e.g., MAO and MgF2), which are developed to improve the degradation rate required for long-term mechanical resistance to loading and excellent osseointegration with bone tissue, thereby promoting functional bone regeneration. Further research is required to deeply verify the safety and efficacy of Mg alloys.
Collapse
Affiliation(s)
- Gianluca Giavaresi
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Daniele Bellavia
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Angela De Luca
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Viviana Costa
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Lavinia Raimondi
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Aurora Cordaro
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Maria Sartori
- Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (D.B.); (A.D.L.); (V.C.); (L.R.); (A.C.); (M.S.)
| | - Silvio Terrando
- Ortopedia Generale, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (S.T.); (A.T.); (G.P.)
| | - Angelo Toscano
- Ortopedia Generale, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (S.T.); (A.T.); (G.P.)
| | - Giovanni Pignatti
- Ortopedia Generale, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy; (S.T.); (A.T.); (G.P.)
| | - Milena Fini
- Direzione Scientifica, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy;
| |
Collapse
|
3
|
Martinez DC, Dobkowska A, Marek R, Ćwieka H, Jaroszewicz J, Płociński T, Donik Č, Helmholz H, Luthringer-Feyerabend B, Zeller-Plumhoff B, Willumeit-Römer R, Święszkowski W. In vitro and in vivo degradation behavior of Mg-0.45Zn-0.45Ca (ZX00) screws for orthopedic applications. Bioact Mater 2023; 28:132-154. [PMID: 37250863 PMCID: PMC10209338 DOI: 10.1016/j.bioactmat.2023.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/26/2023] [Accepted: 05/09/2023] [Indexed: 05/31/2023] Open
Abstract
Magnesium (Mg) alloys have become a potential material for orthopedic implants due to their unnecessary implant removal, biocompatibility, and mechanical integrity until fracture healing. This study examined the in vitro and in vivo degradation of an Mg fixation screw composed of Mg-0.45Zn-0.45Ca (ZX00, in wt.%). With ZX00 human-sized implants, in vitro immersion tests up to 28 days under physiological conditions, along with electrochemical measurements were performed for the first time. In addition, ZX00 screws were implanted in the diaphysis of sheep for 6, 12, and 24 weeks to assess the degradation and biocompatibility of the screws in vivo. Using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDX), micro-computed tomography (μCT), X-ray photoelectron spectroscopy (XPS), and histology, the surface and cross-sectional morphologies of the corrosion layers formed, as well as the bone-corrosion-layer-implant interfaces, were analyzed. Our findings from in vivo testing demonstrated that ZX00 alloy promotes bone healing and the formation of new bone in direct contact with the corrosion products. In addition, the same elemental composition of corrosion products was observed for in vitro and in vivo experiments; however, their elemental distribution and thicknesses differ depending on the implant location. Our findings suggest that the corrosion resistance was microstructure-dependent. The head zone was the least corrosion-resistant, indicating that the production procedure could impact the corrosion performance of the implant. In spite of this, the formation of new bone and no adverse effects on the surrounding tissues demonstrated that the ZX00 is a suitable Mg-based alloy for temporary bone implants.
Collapse
Affiliation(s)
- Diana C. Martinez
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Anna Dobkowska
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Romy Marek
- Department of Orthopedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Hanna Ćwieka
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Jakub Jaroszewicz
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Tomasz Płociński
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| | - Črtomir Donik
- Department of Physics and Chemistry of Materials, Institute of Metals and Technology, University of Ljubljana, Lepi Pot 11, SI-1000, Ljubljana, Slovenia
| | - Heike Helmholz
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | | | - Berit Zeller-Plumhoff
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Regine Willumeit-Römer
- Institute of Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, 21502, Geesthacht, Germany
| | - Wojciech Święszkowski
- Biomaterials Group, Materials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507, Warsaw, Poland
| |
Collapse
|
4
|
Sonnow L, Ziegler A, Pöhler GH, Kirschner MH, Richter M, Cetin M, Unal M, Kose O. Alterations in magnetic resonance imaging characteristics of bioabsorbable magnesium screws over time in humans: a retrospective single center study. Innov Surg Sci 2021; 6:105-113. [PMID: 35224178 PMCID: PMC8826160 DOI: 10.1515/iss-2021-0032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 10/04/2021] [Indexed: 11/28/2022] Open
Abstract
Objectives This study aimed to examine the alterations in magnetic resonance imaging (MRI) characteristics of bioabsorbable magnesium (Mg) screws over time in a single center study in humans. Methods Seventeen patients who underwent medial malleolar (MM) fracture or osteotomy fixation using bioabsorbable Mg screws and had at least one postoperative MRI were included in this retrospective study. Six of them had more than one MRI in the postoperative period and were subject of the artifact reduction measurements. 1.5T or 3T MRI scans were acquired in different periods in each patient. The size and extent of the artifact were assessed independently by two experienced radiologists both quantitatively (distance measurement) and qualitatively (Likert scale). Results In the quantitative measurements of the six follow-up patients the screw’s signal loss artifact extent significantly decreased over the time, regardless of the MRI field strength (p<0.001). The mean artifact reduction was 0.06 mm (95% confidence interval [CI]: 0.05–0.07) for proton density weighted [PDw] and 0.04 mm (95% CI: 0.03–0.05) for T1 weighted (T1w) sequences per week. The qualitative assessments similarly showed significant artifact reduction in all MRI sequences. Different imaging findings, like bone marrow edema (BME), liquid collections, and gas formation were reported. The overall inter-reader agreement was high (κ=0.88, p<0.001). Conclusions The time-dependent artifact reduction of Mg screws in postoperative controls might indicate the expected self-degradation of the Mg implants. In addition, different MRI findings were reported, which are characteristic of Mg implants. Further MRI studies are required to get a better understanding of Mg imaging properties.
Collapse
Affiliation(s)
- Lena Sonnow
- Department of Diagnostic and Interventional Radiology , Hannover Medical School , Hannover , Germany
| | - Andreas Ziegler
- Medizincampus Davos , Davos , Switzerland
- School of Mathematics, Statistics and Computer Science, University of KwaZulu-Natal , Pietermaritzburg , South Africa
- Department of Cardiology , University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf , Hamburg , Germany
| | - Gesa H. Pöhler
- Department of Diagnostic and Interventional Radiology , Hannover Medical School , Hannover , Germany
| | | | | | - Mustafa Cetin
- Department of Radiology , Antalya Education and Research Hospital , Antalya , Turkey
| | - Melih Unal
- Department of Orthopedics and Traumatology , Antalya Education and Research Hospital , Antalya , Turkey
| | - Ozkan Kose
- Department of Orthopedics and Traumatology , Antalya Education and Research Hospital , Antalya , Turkey
| |
Collapse
|
5
|
Jungesblut OD, Moritz M, Spiro AS, Stuecker R, Rupprecht M. Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents. Cartilage 2021; 13:302S-310S. [PMID: 32693621 PMCID: PMC8808896 DOI: 10.1177/1947603520942943] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE Fixation of unstable osteochondritis dissecans (OCD) lesions and displaced osteochondral fragments are frequently performed procedures in pediatric orthopedic surgery. Since 2018, CE-certified MAGNEZIX pins are used in our institution in these cases. The aim of this study was (1) to analyze safety, efficiency, and limitations of magnesium-pin-based fixation of unstable OCD lesions and displaced osteochondral fragments and (2) to report clinical and radiological outcomes at short-term follow-up (FU). DESIGN In this prospective cohort study, 19 patients (10 girls and 9 boys) were included. Inclusion criteria were (1) magnetic resonance imaging-confirmed unstable OCD lesion or displaced osteochondral fragment, (2) fixation with magnesium-based pins, and (3) minimum FU of 6 months. X-rays were taken 6 weeks and 6 months after operation and magnetic resonance imaging scans every 4 to 6 months to assess the healing progress. RESULTS In total 67 pins were used, with a mean of 3.6 ± 1.4 per patient. Average age at surgery was 13.7 years (11-17 years). Mean time of operation was 56 ± 31 minutes, including arthroscopy, fixation, and patellar realignment (n = 6). No intraoperative complications occurred. Average FU was 11.3 ± 4.2 months (6-20 months). No redislocation or new dislocation occurred. Until now a complete radiographic healing occurred in 12 cases. Due to an implant failure in one case 11 weeks after the index surgery a revision became necessary. CONCLUSIONS In short-term FU of 11 ± 4 months MAGNEZIX pins provide high stability after fixation of unstable OCDs and displaced osteochondral fragments leading to uncomplicated and timely healing.
Collapse
Affiliation(s)
- Oliver D. Jungesblut
- Altonaer Kinderkrankenhaus gGmbH,
Hamburg, Germany,Oliver D. Jungesblut, Altonaer
Kinderkrankenhaus gGmbH, Bleickenallee 38, Hamburg 22763, Germany.
| | | | | | | | | |
Collapse
|
6
|
Jung O, Hesse B, Stojanovic S, Seim C, Weitkamp T, Batinic M, Goerke O, Kačarević ŽP, Rider P, Najman S, Barbeck M. Biocompatibility Analyses of HF-Passivated Magnesium Screws for Guided Bone Regeneration (GBR). Int J Mol Sci 2021; 22:ijms222212567. [PMID: 34830451 PMCID: PMC8624161 DOI: 10.3390/ijms222212567] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 11/19/2021] [Accepted: 11/19/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.
Collapse
Affiliation(s)
- Ole Jung
- Clinic and Policlinic for Dermatology and Venereology, University Medical Center Rostock, 18057 Rostock, Germany;
| | | | - Sanja Stojanovic
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | | | - Timm Weitkamp
- Synchrotron SOLEIL, Gif-sur-Yvette, 91190 Saint-Aubin, France;
| | - Milijana Batinic
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Oliver Goerke
- Department of Ceramic Materials, Chair of Advanced Ceramic Materials, Institute for Materials Science and Technologies, Technical University of Berlin, 10623 Berlin, Germany; (M.B.); (O.G.)
| | - Željka Perić Kačarević
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Patrick Rider
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
| | - Stevo Najman
- Department of Biology and Human Genetics, Faculty of Medicine, University of Niš, 18108 Niš, Serbia; (S.S.); (S.N.)
- Scientific Research Center for Biomedicine, Faculty of Medicine, Department for Cell and Tissue Engineering, University of Niš, 18108 Niš, Serbia
| | - Mike Barbeck
- Department of Anatomy Histology, Embryology, Pathology Anatomy and Pathology Histology, Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia;
- Correspondence: ; Tel.: +49-176-810-224-6
| |
Collapse
|
7
|
Zhang J, Jiang Y, Shang Z, Zhao B, Jiao M, Liu W, Cheng M, Zhai B, Guo Y, Liu B, Shi X, Ma B. Biodegradable metals for bone defect repair: A systematic review and meta-analysis based on animal studies. Bioact Mater 2021; 6:4027-4052. [PMID: 33997491 PMCID: PMC8089787 DOI: 10.1016/j.bioactmat.2021.03.035] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Revised: 03/24/2021] [Accepted: 03/24/2021] [Indexed: 12/18/2022] Open
Abstract
Biodegradable metals are promising candidates for bone defect repair. With an evidence-based approach, this study investigated and analyzed the performance and degradation properties of biodegradable metals in animal models for bone defect repair to explore their potential clinical translation. Animal studies on bone defect repair with biodegradable metals in comparison with other traditional biomaterials were reviewed. Data was carefully collected after identification of population, intervention, comparison, outcome, and study design (PICOS), and following the inclusion criteria of biodegradable metals in animal studies. 30 publications on pure Mg, Mg alloys, pure Zn and Zn alloys were finally included after extraction from a collected database of 2543 publications. A qualitative systematic review and a quantitative meta-analysis were performed. Given the heterogeneity in animal model, anatomical site and critical size defect (CSD), biodegradable metals exhibited mixed effects on bone defect repair and degradation in animal studies in comparison with traditional non-degradable metals, biodegradable polymers, bioceramics, and autogenous bone grafts. The results indicated that there were limitations in the experimental design of the included studies, and quality of the evidence presented by the studies was very low. To enhance clinical translation of biodegradable metals, evidence-based research with data validity is needed. Future studies should adopt standardized experimental protocols in investigating the effects of biodegradable metals on bone defect repair with animal models.
Collapse
Affiliation(s)
- Jiazhen Zhang
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Yanbiao Jiang
- Evidence-Based Medicine Center, School of Basic Medical Sciences, Lanzhou University, Lanzhou, 730000, PR China
| | - Zhizhong Shang
- Evidence-Based Medicine Center, School of Basic Medical Sciences, Lanzhou University, Lanzhou, 730000, PR China
| | - Bing Zhao
- Evidence-Based Medicine Center, School of Basic Medical Sciences, Lanzhou University, Lanzhou, 730000, PR China
| | - Mingyue Jiao
- Evidence-Based Medicine Center, School of Basic Medical Sciences, Lanzhou University, Lanzhou, 730000, PR China
| | - Wenbo Liu
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Maobo Cheng
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Bao Zhai
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Yajuan Guo
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Bin Liu
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Xinli Shi
- Center for Medical Device Evaluation, National Medical Products Administration, Beijing, 100081, PR China
| | - Bin Ma
- Evidence-Based Medicine Center, School of Basic Medical Sciences, Lanzhou University, Lanzhou, 730000, PR China
- Institute of Health Data Science, Lanzhou University, Lanzhou, 730000, PR China
| |
Collapse
|
8
|
Helmholz H, Will O, Penate-Medina T, Humbert J, Damm T, Luthringer-Feyerabend B, Willumeit-Römer R, Glüer CC, Penate-Medina O. Tissue responses after implantation of biodegradable Mg alloys evaluated by multimodality 3D micro-bioimaging in vivo. J Biomed Mater Res A 2021; 109:1521-1529. [PMID: 33590952 DOI: 10.1002/jbm.a.37148] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 12/07/2020] [Accepted: 01/25/2021] [Indexed: 12/12/2022]
Abstract
The local response of tissue triggered by implantation of degradable magnesium-based implant materials was investigated in vivo in a murine model. Pins (5.0 mm length by 0.5 mm diameter) made of Mg, Mg-10Gd, and Ti were implanted in the leg muscle tissue of C57Bl/6N mice (n = 6). Implantation was generally well tolerated as documented by only a mild short term increase in a multidimensional scoring index. Lack of difference between the groups indicated that the response was systemic and surgery related rather than material dependent. Longitudinal in vivo monitoring utilizing micro-computed tomography over 42 days demonstrated the highest and most heterogeneous degradation for Mg-10Gd. Elemental imaging of the explants by micro X-ray fluorescence spectrometry showed a dense calcium-phosphate-containing degradation layer. In order to monitor resulting surgery induced and/or implant material associated local cell stress, sphingomyelin based liposomes containing indocyanine green were administered. An initial increase in fluorescent signals (3-7 days after implantation) indicating cell stress at the site of the implantation was measured by in vivo fluorescent molecular tomography. The signal decreased until the 42nd day for all materials. These findings demonstrate that Mg based implants are well tolerated causing only mild and short term adverse reactions.
Collapse
Affiliation(s)
- Heike Helmholz
- Department Biological Characterization, Helmholtz-Center Geesthacht Institute for Material and Coastal Research; Institute of Materials Research, Division of Metallic Biomaterials, Geesthacht, Germany
| | - Olga Will
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| | - Tuula Penate-Medina
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| | - Jana Humbert
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| | - Timo Damm
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| | - Berengere Luthringer-Feyerabend
- Department Biological Characterization, Helmholtz-Center Geesthacht Institute for Material and Coastal Research; Institute of Materials Research, Division of Metallic Biomaterials, Geesthacht, Germany
| | - Regine Willumeit-Römer
- Department Biological Characterization, Helmholtz-Center Geesthacht Institute for Material and Coastal Research; Institute of Materials Research, Division of Metallic Biomaterials, Geesthacht, Germany
| | - Claus-Christian Glüer
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| | - Oula Penate-Medina
- Section Biomedical Imaging and Molecular Imaging, North Competence Center, Department of Radiology and Neuroradiology, Christian-Albrechts-Universität zu Kiel, Kiel, Germany
| |
Collapse
|
9
|
Lin Z, Shen D, Zhou W, Zheng Y, Kong T, Liu X, Wu S, Chu PK, Zhao Y, Wu J, Cheung KM, Yeung KW. Regulation of extracellular bioactive cations in bone tissue microenvironment induces favorable osteoimmune conditions to accelerate in situ bone regeneration. Bioact Mater 2021; 6:2315-2330. [PMID: 33553818 PMCID: PMC7840811 DOI: 10.1016/j.bioactmat.2021.01.018] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 01/14/2021] [Accepted: 01/16/2021] [Indexed: 12/25/2022] Open
Abstract
The design of orthopedic biomaterials has gradually shifted from “immune-friendly” to “immunomodulatory,” in which the biomaterials are able to modulate the inflammatory response via macrophage polarization in a local immune microenvironment that favors osteogenesis and implant-to-bone osseointegration. Despite the well-known effects of bioactive metallic ions on osteogenesis, how extracellular metallic ions manipulate immune cells in bone tissue microenvironments toward osteogenesis and subsequent bone formation has rarely been studied. Herein, we investigate the osteoimmunomodulatory effect of an extracellular bioactive cation (Mg2+) in the bone tissue microenvironment using custom-made poly lactic-co-glycolic acid (PLGA)/MgO-alendronate microspheres that endow controllable release of magnesium ions. The results suggest that the Mg2+-controlled tissue microenvironment can effectively induce macrophage polarization from the M0 to M2 phenotype via the enhancement of anti-inflammatory (IL-10) and pro-osteogenic (BMP-2 and TGF-β1) cytokines production. It also generates a favorable osteoimmune microenvironment that facilitates the proliferation and osteogenic differentiation of bone marrow mesenchymal stem cells. The in vivo results further verify that a large amount of bony tissue, with comparable bone mineral density and mechanical properties, has been generated at an early post-surgical stage in rat intramedullary bone defect models. This study demonstrates that the concept of in situ immunomodulated osteogenesis can be realized in a controlled magnesium tissue microenvironment. Controlled release of Mg2+ was achieved by the microfluidic electrosprayed PLGA/MgO-alendronate microspheres. PLGA/MgO-alendronate microspheres with satisfied osteoimmunomodulatory properties accelerated bone regeneration in vivo. Extracellular Mg2+ induced macrophage switch to M2 phenotype with enhanced expressions of IL-10, BMP-2 and TGF-β1. Osteoimmune microenvironment favourably upregulated the osteogenic expressions of BMSCs.
Collapse
Affiliation(s)
- Zhengjie Lin
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, 518060, China
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- Corresponding author. College of Chemistry and Environmental Engineering, Shenzhen University, China.
| | - Danni Shen
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, 1 Haiyuan 1st Road, Futian District, Shenzhen, China
| | - Weixiao Zhou
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, 518060, China
| | - Yufeng Zheng
- Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing, 100871, China
| | - Tiantian Kong
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, 518060, China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Shuilin Wu
- School of Materials Science & Engineering, the Key Laboratory of Advanced Ceramics and Machining Technology by the Ministry of Education of China, Tianjin University, Tianjin, 300072, China
| | - Paul K. Chu
- Department of Physics, Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Ying Zhao
- Centre for Human Tissues and Organs Degeneration, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Jun Wu
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, 1 Haiyuan 1st Road, Futian District, Shenzhen, China
| | - Kenneth M.C. Cheung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China
| | - Kelvin W.K. Yeung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, 1 Haiyuan 1st Road, Futian District, Shenzhen, China
- Corresponding author. Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China.
| |
Collapse
|
10
|
Wang Q, Xu L, Helmholz H, Willumeit-Römer R, Luthringer-Feyerabend BJC. Effects of degradable magnesium on paracrine signaling between human umbilical cord perivascular cells and peripheral blood mononuclear cells. Biomater Sci 2020; 8:5969-5983. [PMID: 32975550 DOI: 10.1039/d0bm00834f] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Human mesenchymal stem cells (MSC) interact with numerous immune cells that can promote regenerative processes and inhibit inflammatory responses. We hypothesised that the cross-talk between human umbilical cord perivascular cells (HUCPV; an alternative source of MSC) and peripheral blood mononuclear cells (PBMC) could be influenced by degradable transwell magnesium (Mg). To study the correlations between paracrine signaling and specific cellular behaviour during the host response to Mg, we used a transwell coculture system for up to 7 days. The proliferation and viability of both cell types were not significantly influenced by Mg. When HUCPV were cultured with degradable Mg, a moderate inflammation (e.g., lower secretions of pro-inflammatory interleukin 1 beta and IL2, and tumour necrosis factor alpha, interferon gamma, anti-inflammatory interleukins 4, 5, 10, 13, and 1 receptor antagonists and granulocyte colony stimulating factor), and an increased pro-healing M2 macrophage phenotype were observed. Moreover, when PBMC were cultured with degradable Mg, the expression of migration/wound healing related cytokines (interleukin 8, granulocyte-macrophage colony-stimulating factor, monocyte chemoattractant protein 1 and macrophage inflammatory protein 1α/β) was upregulated, accompanied by an increase in the migration ability of HUCPV (cell scratch assay). In addition, an increased pro-osteogenic potential was demonstrated via an increase of osteoblastic markers (e.g., alkaline phosphatase activity, specific gene expression and cytokine release). These results collectively imply that Mg possesses osteo-immunomodulatory properties. They also help to design Mg-based bone substitute biomaterials capable of exhibiting desired immune reactions and good clinical performance.
Collapse
Affiliation(s)
- Qian Wang
- Institute of Materials Research, Division for Metallic Biomaterials, Helmholtz-Zentrum Geesthacht (HZG), Geesthacht, Germany.
| | | | | | | | | |
Collapse
|
11
|
Paish ADM, Nikolov HN, Welch ID, El-Warrak AO, Teeter MG, Naudie DDR, Holdsworth DW. Image-based design and 3D-metal printing of a rat hip implant for use in a clinically representative model of joint replacement. J Orthop Res 2020; 38:1627-1636. [PMID: 32369210 DOI: 10.1002/jor.24706] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 04/06/2020] [Accepted: 04/23/2020] [Indexed: 02/04/2023]
Abstract
The aim of this study was to obtain micro-computed tomography derived measurements of the rat proximal femur, to create parameterized rat hip implants that could be surgically installed in a clinically representative small animal model of joint replacement. The proximal femoral anatomy of N = 25 rats (male, Sprague-Dawley, 390-605 g) was quantified. Key measurements were used to parameterize computer-aided design models of monoblock rat femoral implants. Linear regression analysis was used to determine if rat hip dimensions could be predicted from animal weight. A correlation analysis was used to determine how implants could be scaled to create a range of sizes. Additive manufacturing (3D printing) was used to create implants in medical-grade metal alloys. Linear regressions comparing rat weight to femoral head diameter and neck-head axis length revealed a significant nonzero slope (P < .05). Pearson's correlation analysis revealed five significant correlations between key measurements in the rat femur (P < .05). Implants were installed into both cadaveric and live animals; iterative design modifications were made to prototypes based on these surgical findings. Animals were able to tolerate the installation of implants and were observed ambulating on their affected limbs postoperatively. Clinical significance: We have developed a preclinical rat hip hemiarthroplasty model using image-based and iterative design techniques to create 3D-metal printed implants in medical-grade metal alloys. Our findings support further development of this model for use as a low-cost translational test platform for preclinical orthopaedic research into areas such as osseointegration, metal-on-cartilage wear, and periprosthetic joint infection.
Collapse
Affiliation(s)
- Adam D M Paish
- Bone and Joint Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada
| | - Hristo N Nikolov
- Robarts Research Institute, Western University, London, Ontario, Canada
| | - Ian D Welch
- Animal Care Services, The University of British Columbia, Vancouver, British Columbia, Canada
| | - Alexander O El-Warrak
- Surgery Team, Premier Veterinary Group by Ethos Animal Health, Orland Park, Illinois
| | - Matthew G Teeter
- Bone and Joint Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada.,Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
| | - Douglas D R Naudie
- Bone and Joint Institute, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada.,Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
| | - David W Holdsworth
- Bone and Joint Institute, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Western University, London, Ontario, Canada.,Robarts Research Institute, Western University, London, Ontario, Canada.,Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
12
|
Campos Becerra LH, Hernández Rodríguez MAL, Esquivel Solís H, Lesso Arroyo R, Torres Castro A. Bio-inspired biomaterial Mg-Zn-Ca: a review of the main mechanical and biological properties of Mg-based alloys. Biomed Phys Eng Express 2020; 6:042001. [PMID: 33444260 DOI: 10.1088/2057-1976/ab9426] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The toxicity of alloying elements in magnesium alloys used for biomedical purposes is an interesting and innovative subject, due to the great technological advances that would result from their application in medical devices (MDs) in traumatology. Recently promising results have been published regarding the rates of degradation and mechanical integrity that can support Mg alloys; this has led to an interest in understanding the toxicological features of these emerging biomaterials. The growing interest of different segments of the MD market has increased the determination of different research groups to clarify the behavior of alloying elements in vivo. This review covers the influence of the alloying elements on the body, the toxicity of the elements in Mg-Zn-Ca, as well as the mechanical properties, degradation, processes of obtaining the alloy, medical approaches and future perspectives on the use of the Mg in the manufacture of MDs for various medical applications.
Collapse
Affiliation(s)
- Luis Humberto Campos Becerra
- Facultad de Ingeniería Mecánica y Eléctrica., Biomateriales. Universidad Autónoma de Nuevo León (UANL), Pedro de Alba S/N, Ciudad Universitaria, San Nicolás de los Garza, México
| | | | | | | | | |
Collapse
|
13
|
Sun Y, Wu H, Wang W, Zan R, Peng H, Zhang S, Zhang X. Translational status of biomedical Mg devices in China. Bioact Mater 2019; 4:358-365. [PMID: 31909297 PMCID: PMC6939060 DOI: 10.1016/j.bioactmat.2019.11.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 10/29/2019] [Accepted: 11/06/2019] [Indexed: 12/14/2022] Open
Abstract
Magnesium (Mg) and its alloys as temporary medical implants with biodegradable and properly mechanical properties have been investigated for a long time. There are already three kinds of biodegradable Mg implants which are approved by Conformite Europeene (CE) or Korea Food and Drug Administration (KFDA), but not China Food and Drug Administration (CFDA, now it is National Medical Products Administration, NMPA). As we know, Chinese researchers, surgeons, and entrepreneurs have tried a lot to research and develop biodegradable Mg implants which might become other new approved implants for clinical applications. So in this review, we present the representative Mg implants of three categories, orthopedic implants, surgical implants, and intervention implants and provide an overview of current achievement in China from academic publications and Chinese patents. We would like to provide a systematic way to translate Mg and its alloy implants from experiment designs to clinical products.
Collapse
Affiliation(s)
- Yu Sun
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Hongliu Wu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Wenhui Wang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Rui Zan
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Hongzhou Peng
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Shaoxiang Zhang
- Suzhou Origin Medical Technology Co. Ltd., Suzhou, 215513, China
| | - Xiaonong Zhang
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
- Suzhou Origin Medical Technology Co. Ltd., Suzhou, 215513, China
| |
Collapse
|
14
|
Lin Z, Wu S, Liu X, Qian S, Chu PK, Zheng Y, Cheung KMC, Zhao Y, Yeung KWK. A surface-engineered multifunctional TiO 2 based nano-layer simultaneously elevates the corrosion resistance, osteoconductivity and antimicrobial property of a magnesium alloy. Acta Biomater 2019; 99:495-513. [PMID: 31518705 DOI: 10.1016/j.actbio.2019.09.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 08/12/2019] [Accepted: 09/06/2019] [Indexed: 12/18/2022]
Abstract
Magnesium biometals exhibit great potentials for orthopeadic applications owing to their biodegradability, bioactive effects and satisfactory mechanical properties. However, rapid corrosion of Mg implants in vivo combined with large amount of hydrogen gas evolution is harmful to bone healing process which seriously confines their clinical applications. Enlightened by the superior biocompatibility and corrosion resistance of passive titanium oxide layer automatically formed on titanium alloy, we employ the Ti and O dual plasma ion immersion implantation (PIII) technique to construct a multifunctional TiO2 based nano-layer on ZK60 magnesium substrates for enhanced corrosion resistance, osteoconductivity and antimicrobial activity. The constructed nano-layer (TiO2/MgO) can effectively suppress degradation rate of ZK60 substrates in vitro and still maintain 94% implant volume after post-surgery eight weeks. In animal study, a large amount of bony tissue with increased bone mineral density and trabecular thickness is formed around the PIII treated group in post-operation eight weeks. Moreover, the newly formed bone in the PIII treated group is well mineralized and its mechanical property almost restores to the level of that of surrounding mature bone. Surprisingly, a remarkable killing ratio of 99.31% against S. aureus can be found on the PIII treated sample under ultra-violet (UV) irradiation which mainly attributes to the oxidative stress induced by the reactive oxygen species (ROS). We believe that this multifunctional TiO2 based nano-layer not only controls the degradation of magnesium implant, but also regulates its implant-to-bone integration effectively. STATEMENT OF SIGNIFICANCE: Rapid corrosion of magnesium implants is the major issue for orthopaedic applications. Inspired by the biocompatibility and corrosion resistance of passive titanium oxide layer automatically formed on titanium alloy, we construct a multifunctional TiO2/MgO nanolayer on magnesium substrates to simultaneously achieve superior corrosion resistance, satisfactory osteoconductivity in rat intramedullary bone defect model and excellent antimicrobial activity against S. aureus under UV irradiation. The current findings suggest that the specific TiO2/MgO nano-layer on magnesium surface can achieve the three objectives aforementioned and we believe this study can demonstrate the potential of biodegradable metals for future clinical applications.
Collapse
Affiliation(s)
- Zhengjie Lin
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, PR China; Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China; Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, 1 Haiyuan 1st Road, Futian District, Shenzhen, China
| | - Shuilin Wu
- School of Materials Science & Engineering, the Key Laboratory of Advanced Ceramics and Machining Technology by the Ministry of Education of China, Tianjin University, Tianjin 300072, China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China
| | - Shi Qian
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; Cixi Center of Biomaterials Surface Engineering, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Ningbo, PR China
| | - Paul K Chu
- Department of Physics, Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Yufeng Zheng
- State Key Laboratory for Turbulence and Complex System and Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871, China
| | - Kenneth M C Cheung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China
| | - Ying Zhao
- Centre for Human Tissues and Organs Degeneration, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
| | - Kelvin W K Yeung
- Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China; Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong Shenzhen Hospital, 1 Haiyuan 1st Road, Futian District, Shenzhen, China.
| |
Collapse
|
15
|
Naujokat H, Ruff CB, Klüter T, Seitz JM, Açil Y, Wiltfang J. Influence of surface modifications on the degradation of standard-sized magnesium plates and healing of mandibular osteotomies in miniature pigs. Int J Oral Maxillofac Surg 2019; 49:272-283. [PMID: 31227276 DOI: 10.1016/j.ijom.2019.03.966] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Revised: 01/16/2019] [Accepted: 03/17/2019] [Indexed: 11/28/2022]
Abstract
Biodegradable magnesium alloys are suitable osteosynthesis materials. Despite the alloy composition, surface modifications appear to have an influence on the degradation process and biocompatibility. The aim of this study was to investigate the impact of hydrogenation and fluoridation of the surface in a mandibular osteotomy model. Standard-sized plates and screws were implanted in an osteotomy at the mandibular angle in nine miniature pigs. The plates and screws were harvested together with the adjacent tissues at 8 weeks after surgery and were investigated by micro-computed tomography and histological analysis. The bone healing of the osteotomy was undisturbed, independent of the surface properties. The adjacent bone tissue showed new bone formation at the implant surface; however, formation of some lacunae could be observed. The corrosion was between 9.8% and 11.6% (fluoridated<hydrogenated<non-modified) in histological specimens, while radiologically neither the volume nor the density of the osteosynthesis material was reduced in any treatment group. The soft tissues exhibited full biocompatibility with every surface property. In summary, surface modification by hydrogenation and fluoridation did not significantly influence bone healing, biocompatibility, or corrosion kinetics of the magnesium osteosynthesis at the mandibular angle.
Collapse
Affiliation(s)
- H Naujokat
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany.
| | - C B Ruff
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | - T Klüter
- Department of Trauma Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | | | - Y Açil
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| | - J Wiltfang
- Department of Oral and Maxillofacial Surgery, University Hospital of Schleswig-Holstein, Kiel, Germany
| |
Collapse
|
16
|
Mao GW, Gong HB, Wang Y, Li X, Lv R, Sun J, Bian WG. Special Biodegradable Fixation Device for Anterior Cruciate Ligament Reconstruction-Safety and Efficacy in a Beagle Model. ACS Biomater Sci Eng 2018; 4:3600-3609. [PMID: 33450798 DOI: 10.1021/acsbiomaterials.8b00426] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This study aimed to evaluate the safety and efficacy of the special WE43 magnesium alloy stretch plates (SPs) used as fixation device for anterior cruciate ligament (ACL) reconstruction in a beagle model. Eleven beagle dogs underwent ACL reconstruction using WE43 SPs to fix the ligament grafts with the femoral ends, whereas titanium interferences were employed in the tibia ends. Load-to-failure tests were conducted to evaluate the mechanical properties. A comprehensive set of histological observations was performed to observe the local tissue response and assess the status of the attachment between the bone tissue and ligament grafts. Microcomputed tomography and scanning electron microscopy in conjunction with energy spectrum analysis were conducted to evaluate the degradation rate in vivo and investigate the morphology of the cross-section of the SPs and the element distribution in vivo. Immersion tests were employed to investigate the corrosion properties in vitro. The special WE43 SPs showed not only good mechanical strength but also a suitable degradation rate in vivo. The results indicated the special WE43 SP could be considered as a novel fixation device for ACL reconstruction.
Collapse
Affiliation(s)
- Gen-Wen Mao
- Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, People's Republic of China
| | - Hai-Bo Gong
- The State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, People's Republic of China
| | - Ying Wang
- The State Key Laboratory of Mechanical Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, People's Republic of China
| | - Xiang Li
- Department of Health Sciences and Technology, ETH Zurich, Zurich, 78092, Switzerland.,Department of Orthopedics, The Hospital of Balgrist University, Zurich, 78092, Switzerland
| | - Rong Lv
- Department of Orthopedics, The First Affiliated Hospital of The Fourth Military Medical University, Xi'an, Shaanxi, 710032, People's Republic of China
| | - Juan Sun
- Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, People's Republic of China
| | - Wei-Guo Bian
- Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, People's Republic of China
| |
Collapse
|
17
|
Ren L, Yu K, Tan Y. Monitoring and Assessing the Degradation Rate of Magnesium-Based Artificial Bone In Vitro Using a Wireless Magnetoelastic Sensor. SENSORS 2018; 18:s18093066. [PMID: 30213118 PMCID: PMC6165446 DOI: 10.3390/s18093066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 08/29/2018] [Accepted: 09/10/2018] [Indexed: 11/24/2022]
Abstract
A magnetoelastic-based (MB) sensor was employed as a novel method to monitor and assess the degradation rate of magnesium-based artificial bone (MBAB) in vitro, which can be used as an implant to repair a bone defect, providing a quantitative method to depict the degradation rate of MBAB. MBABs were fabricated by the Pro/Engineering software and a precision machine tool using high-purity (HP) magnesium. The MB sensor was embedded in the neutral surface of MBAB by an unharmful quick adhesive, forming the MB sensor-embedded MBAB (EMBAB). The modified simulated body fluid (MSBF) media (PH = 7.4), mimicking the human internal environment, and the NaOH media (PH = 12), accelerating EMBAB’s degradation, were used to immerse the EMBAB for 15 days at 37 °C. The EMBAB was then tested daily on a self-developed experimental platform to monitor the relative output power under a 100 N external force. The results showed that the relative output power of the sensing coil gradually increased with the EMBAB’s degradation. The degradation rate of the EMBAB could be calculated on the basis of the changes of the relative output power caused by the MB sensor and of the degradation time. With the EMBAB’s degradation, an increasing strain directly worked on the MB sensor, significantly changing the value of the relative output power, which means that the EMBAB was characterized by a quick degradation rate. During the 15 days of the experiment, the degradation rates on the 7th and 15th days were 0.005 dbm/day and 0.02 dbm/day, and 0.02 dbm/day and 0.04 dbm/day in MSBF and alkaline media, respectively. Therefore, the MB sensor provides a wireless and passive method to monitor and assess the degradation rate of bone implants in vitro.
Collapse
Affiliation(s)
- Limin Ren
- School of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China.
| | - Kun Yu
- School of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China.
| | - Yisong Tan
- School of Mechanical Engineering, Northeast Electric Power University, Jilin 132012, China.
| |
Collapse
|
18
|
Lin Z, Wu J, Qiao W, Zhao Y, Wong KH, Chu PK, Bian L, Wu S, Zheng Y, Cheung KM, Leung F, Yeung KW. Precisely controlled delivery of magnesium ions thru sponge-like monodisperse PLGA/nano-MgO-alginate core-shell microsphere device to enable in-situ bone regeneration. Biomaterials 2018; 174:1-16. [DOI: 10.1016/j.biomaterials.2018.05.011] [Citation(s) in RCA: 111] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 05/05/2018] [Accepted: 05/05/2018] [Indexed: 12/18/2022]
|
19
|
Naujokat H, Seitz JM, Açil Y, Damm T, Möller I, Gülses A, Wiltfang J. Osteosynthesis of a cranio-osteoplasty with a biodegradable magnesium plate system in miniature pigs. Acta Biomater 2017; 62:434-445. [PMID: 28844965 DOI: 10.1016/j.actbio.2017.08.031] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 07/26/2017] [Accepted: 08/23/2017] [Indexed: 10/19/2022]
Abstract
Biodegradable magnesium alloys are a new class of implant material suitable for bone surgery. The aim of this study was to investigate plates and screws made of magnesium for osteosynthesis in comparison to titanium in a cranial fracture model. Implants were used for internal fixation of a cranio-osteoplasty in nine minipigs. Computed tomography was conducted repeatedly after surgery. The implants and the adjacent tissues were harvested 10, 20 and 30weeks after surgery and investigated by micro-computed tomography and histological analysis. The surgical procedure and the inserted osteosynthesis material were well tolerated by the animals, and the bone healing of the osteoplasty was undisturbed at all times. The adjacent bone showed formation of lacunas in the magnesium group, resulting in a lower bone-to-implant contact ratio than that of titanium (72 vs. 94% at week 30), but this did not lead to clinical side effects. Radiological measurements showed no reduction in osteosynthesis material volume, but indicated signs of degradation: distinct volumes within the magnesium osteosynthesis group had lower density in micro-computed tomography, and these volumes increased up to 9% at week 30. The histological preparations showed areas of translucency and porosity inside the magnesium, but the outer shape of the osteosynthesis material remained unchanged. No fracture or loosening of the osteosynthesis devices appeared. Soft tissue probes confirmed sufficient biocompatibility. Given their biodegradable capacity, biocompatibility, mechanical strength and visibility on radiographs, osteosynthesis plates made of magnesium alloys are suitable for internal fixation procedures. STATEMENT OF SIGNIFICANCE To the best of our knowledge this is the first study that used biodegradable magnesium implants for osteosynthesis in a cranial fracture model. The cranio-osteoplasty in miniature pigs allowed in vivo application of plate and screw osteosynthesis of standard-sized implants and the implementation of surgical procedures similar to those conducted on human beings. The osteosynthesis configuration, size, and mechanical properties of the magnesium implants within this study were comparable to those of titanium-based osteosynthesis materials. The results clearly show that bone healing was undisturbed in all cases and that the biocompatibility to hard- and soft tissue was sufficient. Magnesium implants might help to avoid long-term complications and secondary removal procedures due to their biodegradable properties.
Collapse
|
20
|
Martinez Sanchez AH, Feyerabend F, Laipple D, Willumeit-Römer R, Weinberg A, Luthringer BJ. Chondrogenic differentiation of ATDC5-cells under the influence of Mg and Mg alloy degradation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 72:378-388. [DOI: 10.1016/j.msec.2016.11.062] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 10/25/2016] [Accepted: 11/11/2016] [Indexed: 11/27/2022]
|
21
|
Schaller B, Saulacic N, Beck S, Imwinkelried T, Goh BT, Nakahara K, Hofstetter W, Iizuka T. In vivo degradation of a new concept of magnesium-based rivet-screws in the minipig mandibular bone. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 69:247-54. [DOI: 10.1016/j.msec.2016.06.085] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 06/21/2016] [Accepted: 06/25/2016] [Indexed: 11/16/2022]
|
22
|
Willbold E, Weizbauer A, Loos A, Seitz JM, Angrisani N, Windhagen H, Reifenrath J. Magnesium alloys: A stony pathway from intensive research to clinical reality. Different test methods and approval-related considerations. J Biomed Mater Res A 2016; 105:329-347. [PMID: 27596336 DOI: 10.1002/jbm.a.35893] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2016] [Revised: 07/29/2016] [Accepted: 09/02/2016] [Indexed: 12/21/2022]
Abstract
The first degradable implant made of a magnesium alloy, a compression screw, was launched to the clinical market in March 2013. Many different complex considerations are required for the marketing authorization of degradable implant materials. This review gives an overview of existing and proposed standards for implant testing for marketing approval. Furthermore, different common in vitro and in vivo testing methods are discussed. In some cases, animal tests are inevitable to investigate the biological safety of a novel medical material. The choice of an appropriate animal model is as important as subsequent histological examination. Furthermore, this review focuses on the results of various mechanical tests to investigate the stability of implants for temporary use. All the above aspects are examined in the context of development and testing of magnesium-based biomaterials and their progress them from bench to bedside. A brief history of the first market launch of a magnesium-based degradable implant is given. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 329-347, 2017.
Collapse
Affiliation(s)
- Elmar Willbold
- Department of Orthopedic Surgery, Hannover Medical School, NIFE, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Stadtfelddamm 34, 30625, Hannover, Germany
| | - Andreas Weizbauer
- Department of Orthopedic Surgery, Hannover Medical School, NIFE, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Stadtfelddamm 34, 30625, Hannover, Germany
| | - Anneke Loos
- Biocompatibility Laboratory BioMedimplant, Stadtfelddamm 34, 30625, Hannover, Germany
| | | | - Nina Angrisani
- Department of Orthopedic Surgery, Hannover Medical School, NIFE, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Stadtfelddamm 34, 30625, Hannover, Germany
| | - Henning Windhagen
- Department of Orthopedic Surgery, Hannover Medical School, NIFE, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Stadtfelddamm 34, 30625, Hannover, Germany
| | - Janin Reifenrath
- Department of Orthopedic Surgery, Hannover Medical School, NIFE, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Stadtfelddamm 34, 30625, Hannover, Germany
| |
Collapse
|
23
|
Berger L, Eichler J, Ryll EJS, Fischerauer S, Raschke MJ, Kolbitsch A, Castellani C, Weinberg AM. Advanced interlocking systems to improve heavy-load-bearing characteristics of flexible intramedullary nailing. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 68:358-365. [PMID: 27524031 DOI: 10.1016/j.msec.2016.05.122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 05/04/2016] [Accepted: 05/27/2016] [Indexed: 11/19/2022]
Abstract
Flexible intramedullary nailing (FIN) is a minimally invasive and widespread standard method for osteosynthesis of pediatric long bone fractures. In the case of unstable fractures of the lower extremity, interlocking systems need to be used to prevent axial shortening and subsequent perforation of the nail at its insertion site. In the present study, four different screw-fixed interlocking systems for FINs (Hofer TwinPlug with two 3-mm titanium interlocking screws, Hofer FixPlug with 3-mm titanium interlocking screw, Hofer Plug with 3.5-mm titanium interlocking screw, and Hofer Plug with 3-mm titanium interlocking screw) in comparison with the commonly used Ender stainless steel nails (locked with 3.5-mm screw) were experimentally investigated in cadaveric lamb tibiae, regarding their load characteristics and failure modes in the case of heavy loading. The specimens were subjected to sequential axial cyclic loading of 5000cycles with stepwise increase of the load amplitude until failure. Migration of locking screws and internal damage of bone tissue was quantified by micro-computed tomography (CT) imaging. Ender nails failed on average at a peak load of 800 N, TwinPlugs at 1367 N, FixPlugs at 1222 N, Plugs 3.5mm at 1225 N and Plugs 3.0mm at 971 N. TwinPlugs, FixPlugs, and Plugs 3.5mm failed in a slow manner over several hundred loading cycles, whereas Ender nails and Plugs 3.0mm exhibited abrupt failure without any prior indication. Our results confirm that axial stability of FIN can be further improved by screw-fixed plugs by simultaneously avoiding shortcomings of an eye-locked system, which the Ender nails are. Considering biomechanical results, plug interlocking systems with 3.5-mm screws should be favored over conventional Ender nails and plugs with 3-mm screws.
Collapse
Affiliation(s)
- Leopold Berger
- Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna, Austria.
| | - Johannes Eichler
- Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria
| | - E Jonathan S Ryll
- Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster, Germany
| | - Stefan Fischerauer
- Department of Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria
| | - Michael J Raschke
- Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster, Germany
| | - Andreas Kolbitsch
- Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna, Austria
| | - Christoph Castellani
- Department of Pediatric and Adolescence Surgery, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz, Austria
| | - Annelie-Martina Weinberg
- Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz, Austria
| |
Collapse
|
24
|
Kim JA, Lim J, Naren R, Yun HS, Park EK. Effect of the biodegradation rate controlled by pore structures in magnesium phosphate ceramic scaffolds on bone tissue regeneration in vivo. Acta Biomater 2016; 44:155-67. [PMID: 27554019 DOI: 10.1016/j.actbio.2016.08.039] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 08/13/2016] [Accepted: 08/19/2016] [Indexed: 12/24/2022]
Abstract
UNLABELLED Similar to calcium phosphates, magnesium phosphate (MgP) ceramics have been shown to be biocompatible and support favorable conditions for bone cells. Micropores below 25μm (MgP25), between 25 and 53μm (MgP53), or no micropores (MgP0) were introduced into MgP scaffolds using different sizes of an NaCl template. The porosities of MgP25 and MgP53 were found to be higher than that of MgP0 because of their micro-sized pores. Both in vitro and in vivo analysis showed that MgP scaffolds with high porosity promoted rapid biodegradation. Implantation of the MgP0, MgP25, and MgP53 scaffolds into rabbit calvarial defects (with 4- and 6-mm diameters) was assessed at two times points (4 and 8weeks), followed by analysis of bone regeneration. The micro-CT and histologic analyses of the 4-mm defect showed that the MgP25 and MgP53 scaffolds were degraded completely at 4weeks with simultaneous bone and marrow-like structure regeneration. For the 6-mm defect, a similar pattern of regeneration was observed. These results indicate that the rate of degradation is associated with bone regeneration. The MgP25 and MgP53 scaffold-implanted bone showed a better lamellar structure and enhanced calcification compared to the MgP0 scaffold because of their porosity and degradation rate. Tartrate-resistant acid phosphatase (TRAP) staining indicated that the newly formed bone was undergoing maturation and remodeling. Overall, these data suggest that the pore architecture of MgP ceramic scaffolds greatly influence bone formation and remodeling activities and thus should be considered in the design of new scaffolds for long-term bone tissue regeneration. STATEMENT OF SIGNIFICANCE The pore structural conditions of scaffold, including porosity, pore size, pore morphology, and pore interconnectivity affect cell ingrowth, mechanical properties and biodegradabilities, which are key components of scaffold in bone tissue regeneration. In this study, we designed hierarchical pore structure of the magnesium phosphate (MgP) scaffold by combination of the 3D printing process, self-setting reaction and salt-leaching technique, and first studied the effect of pore structures of bioceramic scaffolds on bone tissue regeneration through both in vitro and in vivo studies (rabbit calvarial model). The MgP scaffolds with higher porosity promoted more rapid biodegradation and enhanced new bone formation and remodeling activities at the same time.
Collapse
|
25
|
Long-term in vivo degradation behavior and near-implant distribution of resorbed elements for magnesium alloys WZ21 and ZX50. Acta Biomater 2016; 42:440-450. [PMID: 27343708 DOI: 10.1016/j.actbio.2016.06.025] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Accepted: 06/17/2016] [Indexed: 11/21/2022]
Abstract
UNLABELLED We report on the long-term effects of degrading magnesium implants on bone tissue in a growing rat skeleton using continuous in vivo micro-Computed Tomography, histological staining and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). Two different magnesium alloys-one rapidly degrading (ZX50) and one slowly degrading (WZ21)-were used to evaluate the bone response and distribution of released Mg and Y ions in the femur of male Sprague-Dawley rats. Regardless of whether the alloy degrades rapidly or slowly, we found that bone recovers restitutio ad integrum after complete degradation of the magnesium implant. The degradation of the Mg alloys generates a significant increase in Mg concentration in the cortical bone near the remaining implant parts, but the Mg accumulation disappears after the implant degrades completely. The degradation of the Y-containing alloy WZ21 leads to Y enrichment in adjacent bone tissues and in newly formed bone inside the medullary space. Locally high Y concentrations suggest migration not only of Y ions but also of Y-containing intermetallic particles. However, after the full degradation of the implant the Y-enrichment disappears almost completely. Hydrogen gas formation and ion release during implant degradation did not harm bone regeneration in our samples. STATEMENT OF SIGNIFICANCE Magnesium is generally considered to be one of the most attractive base materials for biodegradable implants, and many magnesium alloys have been optimized to adjust implant degradation. Delayed degradation, however, generates prolonged presence in the organism with the risk of foreign body reactions. While most studies so far have only ranged from several weeks up to 12months, the present study provides data for complete implant degradation and bone regeneration until 24months, for two magnesium alloys (ZX50, WZ21) with different degradation characteristics. μCT monitoring, histological staining and LA-ICP-MS illustrate the distribution of the elements in the neighboring bony tissues during implant degradation, and reveal in particular high concentrations of the rare-earth element Yttrium.
Collapse
|
26
|
Luthringer BJ, Willumeit-Römer R. Effects of magnesium degradation products on mesenchymal stem cell fate and osteoblastogenesis. Gene 2016; 575:9-20. [DOI: 10.1016/j.gene.2015.08.028] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 08/10/2015] [Accepted: 08/13/2015] [Indexed: 01/02/2023]
|
27
|
Zomorodian A, Santos C, Carmezim M, Silva TE, Fernandes J, Montemor M. “In-vitro” corrosion behaviour of the magnesium alloy with Al and Zn (AZ31) protected with a biodegradable polycaprolactone coating loaded with hydroxyapatite and cephalexin. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.04.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|