1
|
Thangavel M, Elsen S R. Evaluation and optimization of physical, mechanical, and biological characteristics of 3D printed Whitlockite/calcium silicate composite scaffold for bone tissue regeneration using response surface methodology. Biomed Mater 2025; 20:025017. [PMID: 39842082 DOI: 10.1088/1748-605x/adad27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Accepted: 01/22/2025] [Indexed: 01/24/2025]
Abstract
Calcium phosphate-based bioscaffolds are used for bone tissue regeneration because of their physical and chemical resemblance to human bone. Calcium, phosphate, sodium, potassium, magnesium, and silicon are important components of human bone. The successful biomimicking of human bone characteristics involves incorporating all the human bone elements into the scaffold material. In this work, Mg-Whitlockite (WH) and Calcium Silicate (CS) were selected as matrix and reinforcement respectively, because of their desirable elemental composition and regenerative properties. The magnesium in WH increases mineralization in bone, and the silicon ions in CS support vascularization. The Mg-WH was synthesized using the wet chemical method, and powder characterization tests were performed. Response surface methodology (RSM) is used to design the experiments with a combination of material compositions, infill ratios (IFs), and sintering temperatures (STs). The WH/CS bioceramic composite is 3D printed in three different compositions: 100/0, 75/25, and 50/50 wt%, with IFs of 50%, 75%, and 100%. The physical and mechanical characterization study of printed samples is conducted and the result is optimized using RSM. ANOVA (Analysis of Variance) is used to establish the relationship between input parameters and responses. The optimized input parameters were the WH/CS composition of 50/50 wt%, IF of 50%, and ST of 1150 °C, which bring out the best possible combination of physical and mechanical characteristics. The RSM optimized response was a density of 2.27 g cm-3, porosity of 36.74%, wettability of 45.79%, shrinkage of 25.13%, compressive strength of 12 MPa, and compressive modulus of 208.49 MPa with 92% desirability. The biological characterization studies were conducted for the scaffold samples prepared with optimized input parameters. The biological studies confirmed the capabilities of the WH/CS composite scaffolds in bone regenerative applications.
Collapse
Affiliation(s)
- Mahendran Thangavel
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| | - Renold Elsen S
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| |
Collapse
|
2
|
Abdulaziz D, Anastasiou AD, Panagiotopoulou V, Raif EM, Giannoudis PV, Jha A. Physiologically engineered porous titanium/brushite scaffolds for critical-size bone defects: A design and manufacturing study. J Mech Behav Biomed Mater 2023; 148:106223. [PMID: 37976684 DOI: 10.1016/j.jmbbm.2023.106223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
Repairing critical-size bone defects still represents a critical clinical challenge in the field of trauma surgery. This study focuses on a physiological design and manufacturing of porous composite scaffold (titanium Ti with 10 % mole iron doped brushite DCPD-Fe3+) which can mimic the biomechanical properties of natural cortical bone, specifically for the purpose of repairing critical-size defects. To achieve this, the principle of design of experiments (DOE) was applied for investigating the impact of sintering temperature, mineral ratio, and volume fraction of porosity on the mechanical properties of the fabricated scaffolds. The fabricated scaffolds had open porosity up to 60 %, with pore size approximately between 100 μm and 850 μm. The stiffness of the porous composite scaffolds varied between 3.30 GPa and 20.50 GPa, while the compressive strength ranged from approximately 130 MPa-165 MPa at sintering temperatures equal to or exceeding 1000 °C. Scaffolds with higher porosity and mineral content demonstrated lower stiffness values, resembling natural bone. Numerical simulation was employed by Ansys Workbench to investigate the stress and strain distribution of a critical size defect in mid-shaft femur which was designed to be replaced with the fabricated scaffold. The fabricated scaffolds showed flexible biomechanical behaviour at the bone/scaffold interface, generating lower stress levels and indicating a better match with the femoral shaft stiffness. The experimental and numerical findings demonstrated promising applications for manufacturing a patient-specific bone scaffold for critical and potentially large defects for reducing stress shielding and minimizing non-union risk.
Collapse
Affiliation(s)
- Dina Abdulaziz
- School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK.
| | - Antonios D Anastasiou
- Department of Chemical Engineering, University of Manchester, Manchester, M1 3AL, UK
| | | | - El Mostafa Raif
- Faculty of Medicine and Health, School of Dentistry, University of Leeds, Leeds, LS2 9JT, UK
| | - Peter V Giannoudis
- Academic Department of Trauma and Orthopaedic Surgery, School of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Animesh Jha
- School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
3
|
Hayashi K, Kishida R, Tsuchiya A, Ishikawa K. Superiority of Triply Periodic Minimal Surface Gyroid Structure to Strut-Based Grid Structure in Both Strength and Bone Regeneration. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37433180 DOI: 10.1021/acsami.3c06263] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Abstract
The aging population has rapidly driven the demand for bone regeneration. The pore structure of a scaffold is a critical factor that affects its mechanical strength and bone regeneration. Triply periodic minimal surface gyroid structures similar to the trabecular bone structure are considered superior to strut-based lattice structures (e.g., grids) in terms of bone regeneration. However, at this stage, this is only a hypothesis and is not supported by evidence. In this study, we experimentally validated this hypothesis by comparing gyroid and grid scaffolds composed of carbonate apatite. The gyroid scaffolds possessed compressive strength approximately 1.6-fold higher than that of the grid scaffolds because the gyroid structure prevented stress concentration, whereas the grid structure could not. The porosity of gyroid scaffolds was higher than that of the grid scaffolds; however, porosity and compressive strength generally have a trade-off relationship. Moreover, the gyroid scaffolds formed more than twice the amount of bone as grid scaffolds in a critical-sized bone defect in rabbit femur condyles. This favorable bone regeneration using gyroid scaffolds was attributed to the high permeability (i.e., larger volume of macropores or porosity) and curvature profile of the gyroid structure. Thus, this study validated the conventional hypothesis using in vivo experiments and revealed factors that led to this hypothetical outcome. The findings of this study are expected to contribute to the development of scaffolds that can achieve early bone regeneration without sacrificing the mechanical strength.
Collapse
Affiliation(s)
- Koichiro Hayashi
- Department of Biomaterials, Faculty of Dental Science, Kyushu University 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Ryo Kishida
- Department of Biomaterials, Faculty of Dental Science, Kyushu University 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Akira Tsuchiya
- Department of Biomaterials, Faculty of Dental Science, Kyushu University 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Kunio Ishikawa
- Department of Biomaterials, Faculty of Dental Science, Kyushu University 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
4
|
Li J, Kim C, Pan CC, Babian A, Lui E, Young JL, Moeinzadeh S, Kim S, Yang YP. Hybprinting for musculoskeletal tissue engineering. iScience 2022; 25:104229. [PMID: 35494239 PMCID: PMC9051619 DOI: 10.1016/j.isci.2022.104229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
This review presents bioprinting methods, biomaterials, and printing strategies that may be used for composite tissue constructs for musculoskeletal applications. The printing methods discussed include those that are suitable for acellular and cellular components, and the biomaterials include soft and rigid components that are suitable for soft and/or hard tissues. We also present strategies that focus on the integration of cell-laden soft and acellular rigid components under a single printing platform. Given the structural and functional complexity of native musculoskeletal tissue, we envision that hybrid bioprinting, referred to as hybprinting, could provide unprecedented potential by combining different materials and bioprinting techniques to engineer and assemble modular tissues.
Collapse
Affiliation(s)
- Jiannan Li
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA
| | - Carolyn Kim
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA.,Department of Mechanical Engineering, 416 Escondido Mall, Stanford University, Stanford, CA 94305, USA
| | - Chi-Chun Pan
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA.,Department of Mechanical Engineering, 416 Escondido Mall, Stanford University, Stanford, CA 94305, USA
| | - Aaron Babian
- Department of Biological Sciences, University of California, Davis CA 95616, USA
| | - Elaine Lui
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA.,Department of Mechanical Engineering, 416 Escondido Mall, Stanford University, Stanford, CA 94305, USA
| | - Jeffrey L Young
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA
| | - Seyedsina Moeinzadeh
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA
| | - Sungwoo Kim
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA
| | - Yunzhi Peter Yang
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, 300 Pasteur Drive BMI 258, Stanford, CA 94305, USA.,Department of Materials Science and Engineering, Stanford University, 496 Lomita Mall, Stanford, CA 94305, USA.,Department of Bioengineering, Stanford University, 443 Via Ortega, Stanford, CA 94305, USA
| |
Collapse
|
5
|
Xu Z, Wang N, Ma Y, Dai H, Han B. Preparation and study of 3D printed dipyridamole/β-tricalcium phosphate/ polyvinyl alcohol composite scaffolds in bone tissue engineering. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2021.103053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
6
|
Zhang R, Hu J, Chen H, Ding Z, Ouyang Y, Zhang Q, Yan Y. A novel degradable tricalcium silicate/calcium polyphosphate/polyvinyl alcohol organic-inorganic composite cement for bone filling. J Biomater Appl 2021; 36:772-788. [PMID: 34102909 DOI: 10.1177/08853282211020399] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this study, tricalcium silicate (C3S) calcium/polyphosphate/polyvinyl alcohol organic-inorganic self-setting composites were successfully designed. A variety of tests were conducted to characterize their self-setting properties, mechanical properties, degradation properties, and related biological properties. The composite bone cements showed a short setting time (5.5-37.5 min) with a 5:5-6:4 ratio of C3S/CPP to maintain a stable compressive strength (28 MPa). In addition, PVA effectively reduced the brittleness of the inorganic phase. Degradation experiments confirmed the sustainable surface degradation of bone cement. A maximum degradation rate of 49% was reached within 56 days, and the structure remained intact without collapse. Culturing MC3T3 cells with bone cement extracts revealed that the composite bone cements had excellent biological properties in vitro. The original extract showed a proliferation promotion effect on cells, whereas most of the other original extracts of degradable bone cements were toxic to the cells. Meanwhile, extracellular matrix mineralization and alkaline phosphatase expression showed remarkable effects on cell differentiation. In addition, a good level of adhesion of cells to the surfaces of materials was observed. Taken together, these results indicate that C3S/CPP/PVA composite bone cements have great potential in bone defect filling for fast curing.
Collapse
Affiliation(s)
- Rongguang Zhang
- School of Chemical Engineering, Sichuan University, Chengdu, P.R. China
| | - Jinbo Hu
- School of Chemical Engineering, Sichuan University, Chengdu, P.R. China
| | - Hong Chen
- College of Physical Science and Technology, Sichuan University, Chengdu, P.R. China
| | - Zhengwen Ding
- College of Physical Science and Technology, Sichuan University, Chengdu, P.R. China
| | - Yalan Ouyang
- School of Chemical Engineering, Sichuan University, Chengdu, P.R. China
| | - Qiyi Zhang
- School of Chemical Engineering, Sichuan University, Chengdu, P.R. China
| | - Yonggang Yan
- College of Physical Science and Technology, Sichuan University, Chengdu, P.R. China
| |
Collapse
|
7
|
Kok J, Širka A, Liu Y, Tarasevičius Š, Belickas J, Tägil M, Lidgren L, Isaksson H, Raina DB. Augmenting a dynamic hip screw with a calcium sulfate/hydroxyapatite biomaterial. Med Eng Phys 2021; 92:102-109. [PMID: 34167704 DOI: 10.1016/j.medengphy.2021.05.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/30/2021] [Accepted: 05/09/2021] [Indexed: 11/28/2022]
Abstract
Internal fixation failure in hip fractures can lead to reoperation. Calcium sulfate/hydroxyapatite (CaS/HA) is a biomaterial that can be used for augmenting fracture fixation. We aimed to determine whether an injection of 2 ml CaS/HA increases the fixation of a dynamic hip screw inserted in synthetic and human trabecular bone. The study consists of two parts: 1) synthetic bone blocks (n = 74), with three subgroups: empty (cannulated screw, no injection), cannulated, and fenestrated; and 2) osteoporotic human femoral heads (n = 29), with the same subgroups. The heads were imaged using µCT. Bone volume fraction, insertion angle, and head diameter were measured. Pullout tests were performed and peak force, stiffness, and work were measured. The fenestrated group showed increases in pullout strength compared to no injection in the synthetic blocks. The cannulated group showed a higher pullout strength in low-density blocks. In the femoral heads, the variation was larger and there were no significant differences between groups. The bone volume fraction correlated with the peak force and work, and the insertion angle correlated with the stiffness. CaS/HA can improve the fixation of a dynamic hip screw. For clinical use, spreading of the material around the threads of the screw must be ensured.
Collapse
Affiliation(s)
- Joeri Kok
- Department of Biomedical Engineering, Lund University, Box 118, 22100 Lund, Sweden.
| | - Aurimas Širka
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Yang Liu
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Šarūnas Tarasevičius
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Juozas Belickas
- Department of Orthopedics and Traumatology, Hospital of Lithuanian University of Health Sciences Kaunas Clinics, Eiveniu ave.2, Kaunas, Lithuania.
| | - Magnus Tägil
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Lars Lidgren
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Box 118, 22100 Lund, Sweden; Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| | - Deepak Bushan Raina
- Department of Clinical Sciences, Orthopedics, Faculty of Medicine, Lund University, BMC C12, 22184 Lund, Sweden.
| |
Collapse
|
8
|
Şahin E, Çiftçioğlu M. Compositional, microstructural and mechanical effects of NaCl porogens in brushite cement scaffolds. J Mech Behav Biomed Mater 2021; 116:104363. [PMID: 33550144 DOI: 10.1016/j.jmbbm.2021.104363] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 01/19/2021] [Accepted: 01/21/2021] [Indexed: 11/30/2022]
Abstract
Modification of the setting process of brushite cements by varying the concentration of ions that alter calcium phosphate crystallization kinetics, is known to enable control on the monetite conversion extent and the accompanying microporosity. This is useful because monetite serves as a suitable matrix in macroporous scaffolds due to its higher phase stability and finer crystal morphology compared to its hydrous counterpart brushite. In this study the synergistic effect of NaCl and citric acid on the microstructural evolution of brushite cement was demonstrated and microporosity of macroporous monetite-rich cement blocks was minimized by a variable NaCl porogen size distribution approach. Initially, maximum packing ratio of various combinations of NaCl size groups in PEG were determined by their rheological analysis in a range between 57% and 69%. Statistical analysis revealed a positive correlation between the amounts of NaCl particles under 38μm and 212μm and the maximum packing ratio. Further broadening the size distributions of NaCl porogens with fine cement precursors was effective in increasing the solids packing ratio of cement blocks more than the maximum packing ratio for the porogens. This improvement in packing was accompanied by a reduction in microporosity despite the increase in micropore volume with ion induced monetite formation. The detrimental effect of the microporosity introduced to the structure during monetite formation was balanced for some size distributions and not so much for others, thereby resulting in a wide range of porosities and mechanical properties. Thus, the exponential dependence of mechanical properties on porosity and the mechanical properties of monetite-rich macroporous blocks at the theoretical zero-porosity were determined according to Rice's model. Zero-porosity extrapolations were much higher than those predicted for brushite cement, contrary to the common assumption that brushite is mechanically stronger than monetite.
Collapse
Affiliation(s)
- Erdem Şahin
- Department of Metallurgical and Materials Engineering, Muğla Sıtkı Koçman University, Muğla, Turkey.
| | - Muhsin Çiftçioğlu
- Department of Chemical Engineering, İzmir Institute of Technology, İzmir, Turkey.
| |
Collapse
|
9
|
Mellgren T, Trbakovic A, Thor A, Ekman S, Ley C, Öhman-Mägi C, Johansson PH, Jensen-Waern M, Hedenqvist P. Guided bone tissue regeneration using a hollow calcium phosphate based implant in a critical size rabbit radius defect. Biomed Mater 2021; 16. [PMID: 33477115 DOI: 10.1088/1748-605x/abde6f] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 01/21/2021] [Indexed: 11/11/2022]
Abstract
Long bone fractures are common and sometimes difficult to treat. Autologous bone (AB), bovine bone and calcium phosphates are used to stimulate bone growth with varying results. In the present study, a calcium phosphate cement (CPC) that previously showed promising grafting capabilities was evaluated for the first time in a long bone defect. A radius defect of 20 mm was created in twenty rabbits. The defect was filled by either a hollow CPC implant that had been previously manufactured as a replica of a rabbit radius through indirect 3D printing, or by particulate AB as control. Defect filling and bone formation was evaluated after 12 weeks by combining micro computed tomography (μCT) and scoring of 3D images, together with histomorphometry and histology. The μCT and histomorphometric evaluations showed a similar amount of filling of the defect (combining graft and bone) between the CPC and AB group, but the scoring of 3D images showed that the filling in the CPC group was significantly larger. Histologically the AB graft could not be distinguished from the new bone. The AB treated defects were found to be composed of more bone than the CPC group, including reorganised cancellous and cortical bone. Both the CPC and AB material was associated with new bone formation, also in the middle of the defect, which could result in closing of the otherwise critically sized gap. This study shows the potential for an indirectly 3D printed implant in guided bone regeneration in critically sized long bone defects.
Collapse
Affiliation(s)
- Torbjörn Mellgren
- Department of Engineering Sciences, Uppsala University, PO Box 534, Uppsala, 75121, SWEDEN
| | - Amela Trbakovic
- Surgical Sciences, Plastic & Oral Maxillofacial Surgery, Uppsala University, Käkkirurgiska kliniken, Akademiska sjukhuset ingång 79, Uppsala, 751 85, SWEDEN
| | - Andreas Thor
- Surgical Sciences, Plastic & Oral Maxillofacial Surgery, Uppsala University, Käkkirurgiska kliniken, Akademiska sjukhuset ingång 79, Uppsala, 751 85, SWEDEN
| | - Stina Ekman
- Biomedical Sciences and Veterinary Public Health, Swedish University of Agricultural Sciences, PO Box 7028, Uppsala, 750 07, SWEDEN
| | - Cecilia Ley
- Biomedical Sciences and Veterinary Public Health, Swedish University of Agricultural Sciences, PO Box 7028, Uppsala, 750 07, SWEDEN
| | | | - Petra Hammarström Johansson
- Prosthodontics, Institution for odontology, Sahlgrenska Academy at University of Gothenburg , Medicinaregaran 12, 413 90 Göteborg, Sweden, Gothenburg, 413 90, SWEDEN
| | - Marianne Jensen-Waern
- Clinical Sciences, Swedish University of Agricultural Sciences, PO Box 7054, Uppsala, 750 07, SWEDEN
| | - Patricia Hedenqvist
- Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, SWEDEN
| |
Collapse
|
10
|
Kirillova A, Nillissen O, Liu S, Kelly C, Gall K. Reinforcement and Fatigue of a Bioinspired Mineral-Organic Bioresorbable Bone Adhesive. Adv Healthc Mater 2021; 10:e2001058. [PMID: 33111508 DOI: 10.1002/adhm.202001058] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/25/2020] [Indexed: 12/21/2022]
Abstract
Bioresorbable bone adhesives may provide remarkable clinical solutions in areas ranging from fixation and osseointegration of permanent implants to the direct healing and fusion of bones without permanent fixation hardware. Mechanical properties of bone adhesives are critical for their successful application in vivo. Reinforcement of a tetracalcium phosphate-phosphoserine bone adhesive is investigated using three degradable reinforcement strategies: poly(lactic-co-glycolic) (PLGA) fibers, PLGA sutures, and chitosan lactate. All three approaches lead to higher compressive strengths of the material and better fatigue performance. Reinforcement with PLGA fibers and chitosan lactate results in a 100% probability of survival of samples at 20 MPa maximum compressive stress level, which is almost ten times higher compared to compressive loads observed in the intervertebral discs of the spine in vivo. High adhesive shear strength of 5.1 MPa is achieved for fiber-reinforced bone adhesive by tuning the surface architecture of titanium samples. Finally, biological and biomechanical performance of the fiber-reinforced adhesive is evaluated in a rabbit distal femur osteotomy model, showing the potential of the bone adhesive for clinical use.
Collapse
Affiliation(s)
- Alina Kirillova
- Department of Mechanical Engineering and Materials Science Pratt School of Engineering Duke University Durham NC 27708 USA
| | - Olivia Nillissen
- Department of Biomedical Engineering Pratt School of Engineering Duke University Durham NC 27708 USA
| | - Samuel Liu
- Department of Mechanical Engineering and Materials Science Pratt School of Engineering Duke University Durham NC 27708 USA
| | - Cambre Kelly
- Department of Biomedical Engineering Pratt School of Engineering Duke University Durham NC 27708 USA
| | - Ken Gall
- Department of Mechanical Engineering and Materials Science Pratt School of Engineering Duke University Durham NC 27708 USA
- Department of Biomedical Engineering Pratt School of Engineering Duke University Durham NC 27708 USA
| |
Collapse
|
11
|
Paknahad A, Goudarzi M, Kucko NW, Leeuwenburgh SC, Sluys LJ. Calcium phosphate cement reinforced with poly (vinyl alcohol) fibers: An experimental and numerical failure analysis. Acta Biomater 2021; 119:458-471. [PMID: 33164819 DOI: 10.1016/j.actbio.2020.10.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 10/07/2020] [Accepted: 10/09/2020] [Indexed: 10/23/2022]
Abstract
Calcium phosphate cements (CPCs) have been widely used during the past decades as biocompatible bone substitution in maxillofacial, oral and orthopedic surgery. CPCs are injectable and are chemically resemblant to the mineral phase of native bone. Nevertheless, their low fracture toughness and high brittleness reduce their clinical applicability to weakly loaded bones. Reinforcement of CPC matrix with polymeric fibers can overcome these mechanical drawbacks and significantly enhance their toughness and strength. Such fiber-reinforced calcium phosphate cements (FRCPCs) have the potential to act as advanced bone substitute in load-bearing anatomical sites. This work achieves integrated experimental and numerical characterization of the mechanical properties of FRCPCs under bending and tensile loading. To this end, a 3-D numerical gradient enhanced damage model combined with a dimensionally-reduced fiber model are employed to develop a computational model for material characterization and to simulate the failure process of fiber-reinforced CPC matrix based on experimental data. In addition, an advanced interfacial constitutive law, derived from micromechanical pull-out tests, is used to represent the interaction between the polymeric fiber and CPC matrix. The presented computational model is successfully validated with the experimental results and offers a firm basis for further investigations on the development of numerical and experimental analysis of fiber-reinforced bone cements.
Collapse
|
12
|
Schröter L, Kaiser F, Stein S, Gbureck U, Ignatius A. Biological and mechanical performance and degradation characteristics of calcium phosphate cements in large animals and humans. Acta Biomater 2020; 117:1-20. [PMID: 32979583 DOI: 10.1016/j.actbio.2020.09.031] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 08/21/2020] [Accepted: 09/15/2020] [Indexed: 12/11/2022]
Abstract
Calcium phosphate cements (CPCs) have been used to treat bone defects and support bone regeneration because of their good biocompatibility and osteointegrative behavior. Since their introduction in the 1980s, remarkable clinical success has been achieved with these biomaterials, because they offer the unique feature of being moldable and even injectable into implant sites, where they harden through a low-temperature setting reaction. However, despite decades of research efforts, two major limitations concerning their biological and mechanical performance hamper a broader clinical use. Firstly, achieving a degradation rate that is well adjusted to the dynamics of bone formation remains a challenging issue. While apatite-forming CPCs frequently remain for years at the implant site without major signs of degradation, brushite-forming CPCs are considered to degrade to a greater extent. However, the latter tend to convert into lower soluble phases under physiological conditions, which makes their degradation behavior rather unpredictable. Secondly, CPCs exhibit insufficient mechanical properties for load bearing applications because of their inherent brittleness. This review places an emphasis on these limitations and provides an overview of studies that have investigated the biological and biomechanical performance as well as the degradation characteristics of different CPCs after implantation into trabecular bone. We reviewed studies performed in large animals, because they mimic human bone physiology more closely in terms of bone metabolism and mechanical loading conditions compared with small laboratory animals. We compared the results of these studies with clinical trials that have dealt with the degradation behavior of CPCs after vertebroplasty and kyphoplasty.
Collapse
Affiliation(s)
- Lena Schröter
- Institute for Orthopedic Research and Biomechanics, Ulm University Medical Center, Helmholtzstrasse 14, D-89081 Ulm, Germany
| | - Friederike Kaiser
- Department for Functional Materials in Medicine and Dentistry, University of Würzburg, Pleicherwall 2, D-97070 Würzburg, Germany
| | - Svenja Stein
- Institute for Orthopedic Research and Biomechanics, Ulm University Medical Center, Helmholtzstrasse 14, D-89081 Ulm, Germany
| | - Uwe Gbureck
- Department for Functional Materials in Medicine and Dentistry, University of Würzburg, Pleicherwall 2, D-97070 Würzburg, Germany.
| | - Anita Ignatius
- Institute for Orthopedic Research and Biomechanics, Ulm University Medical Center, Helmholtzstrasse 14, D-89081 Ulm, Germany
| |
Collapse
|
13
|
Lewin S, Fleps I, Neuhaus D, Öhman-Mägi C, Ferguson SJ, Persson C, Helgason B. Implicit and explicit finite element models predict the mechanical response of calcium phosphate-titanium cranial implants. J Mech Behav Biomed Mater 2020; 112:104085. [PMID: 33080431 DOI: 10.1016/j.jmbbm.2020.104085] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 08/14/2020] [Accepted: 09/08/2020] [Indexed: 11/29/2022]
Abstract
The structural integrity of cranial implants is of great clinical importance, as they aim to provide cerebral protection after neurosurgery or trauma. With the increased use of patient-specific implants, the mechanical response of each implant cannot be characterized experimentally in a practical way. However, computational models provide an excellent possibility for efficiently predicting the mechanical response of patient-specific implants. This study developed finite element models (FEMs) of titanium-reinforced calcium phosphate (CaP-Ti) implants. The models were validated with previously obtained experimental data for two different CaP-Ti implant designs (D1 and D2), in which generically shaped implant specimens were loaded in compression at either quasi-static (1 mm/min) or impact (5 kg, 1.52 m/s) loading rates. The FEMs showed agreement with experimental data in the force-displacement response for both implant designs. The implicit FEMs predicted the peak load with an underestimation for D1 (9%) and an overestimation for D2 (11%). Furthermore, the shape of the force-displacement curves were well predicted. In the explicit FEMs, the first part of the force-displacement response showed 5% difference for D1 and 2% difference for D2, with respect to the experimentally derived peak loads. The explicit FEMs efficiently predicted the maximum displacements with 1% and 4% difference for D1 and D2, respectively. Compared to the CaP-Ti implant, an average parietal cranial bone FEM showed a stiffer response, greater energy absorption and less deformation under the same impact conditions. The framework developed for modelling the CaP-Ti implants has a potential for modelling CaP materials in other composite implants in future studies since it only used literature based input and matched boundary conditions. Furthermore, the developed FEMs make an important contribution to future evaluations of patient-specific CaP-Ti cranial implant designs in various loading scenarios.
Collapse
Affiliation(s)
- Susanne Lewin
- Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden.
| | - Ingmar Fleps
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | | | - Caroline Öhman-Mägi
- Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
| | | | - Cecilia Persson
- Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
| | | |
Collapse
|
14
|
Paknahad A, Kucko NW, Leeuwenburgh SC, Sluys LJ. Experimental and numerical analysis on bending and tensile failure behavior of calcium phosphate cements. J Mech Behav Biomed Mater 2020; 103:103565. [DOI: 10.1016/j.jmbbm.2019.103565] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 11/26/2019] [Accepted: 11/27/2019] [Indexed: 10/25/2022]
|
15
|
Acciaioli A, Falco L, Baleani M. Measurement of apparent mechanical properties of trabecular bone tissue: Accuracy and limitation of digital image correlation technique. J Mech Behav Biomed Mater 2020; 103:103542. [DOI: 10.1016/j.jmbbm.2019.103542] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 10/21/2019] [Accepted: 11/15/2019] [Indexed: 01/02/2023]
|
16
|
Diloksumpan P, de Ruijter M, Castilho M, Gbureck U, Vermonden T, van Weeren PR, Malda J, Levato R. Combining multi-scale 3D printing technologies to engineer reinforced hydrogel-ceramic interfaces. Biofabrication 2020; 12:025014. [PMID: 31918421 PMCID: PMC7116207 DOI: 10.1088/1758-5090/ab69d9] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Multi-material 3D printing technologies that resolve features at different lengths down to the microscale open new avenues for regenerative medicine, particularly in the engineering of tissue interfaces. Herein, extrusion printing of a bone-biomimetic ceramic ink and melt electrowriting (MEW) of spatially organized polymeric microfibres are integrated for the biofabrication of an osteochondral plug, with a mechanically reinforced bone-to-cartilage interface. A printable physiological temperature-setting bioceramic, based on α-tricalcium phosphate, nanohydroxyapatite and a custom-synthesized biodegradable and crosslinkable poloxamer, was developed as bone support. The mild setting reaction of the bone ink enabled us to print directly within melt electrowritten polycaprolactone meshes, preserving their micro-architecture. Ceramic-integrated MEW meshes protruded into the cartilage region of the composite plug, and were embedded with mechanically soft gelatin-based hydrogels, laden with articular cartilage chondroprogenitor cells. Such interlocking design enhanced the hydrogel-to-ceramic adhesion strength >6.5-fold, compared with non-interlocking fibre architectures, enabling structural stability during handling and surgical implantation in osteochondral defects ex vivo. Furthermore, the MEW meshes endowed the chondral compartment with compressive properties approaching those of native cartilage (20-fold reinforcement versus pristine hydrogel). The osteal and chondral compartment supported osteogenesis and cartilage matrix deposition in vitro, and the neo-synthesized cartilage matrix further contributed to the mechanical reinforcement at the ceramic-hydrogel interface. This multi-material, multi-scale 3D printing approach provides a promising strategy for engineering advanced composite constructs for the regeneration of musculoskeletal and connective tissue interfaces.
Collapse
Affiliation(s)
- Paweena Diloksumpan
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Lewin S, Åberg J, Neuhaus D, Engqvist H, Ferguson SJ, Öhman-Mägi C, Helgason B, Persson C. Mechanical behaviour of composite calcium phosphate-titanium cranial implants: Effects of loading rate and design. J Mech Behav Biomed Mater 2020; 104:103701. [PMID: 32174441 DOI: 10.1016/j.jmbbm.2020.103701] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 02/04/2020] [Accepted: 02/13/2020] [Indexed: 11/28/2022]
Abstract
Cranial implants are used to repair bone defects following neurosurgery or trauma. At present, there is a lack of data on their mechanical response, particularly in impact loading. The aim of the present study was to assess the mechanical response of a recently developed composite calcium phosphate-titanium (CaP-Ti) implant at quasi-static and impact loading rates. Two different designs were tested, referred to as Design 1 (D1) and Design 2 (D2). The titanium structures in the implant specimens were additively manufactured by a powder-bed fusion process and subsequently embedded in a self-setting CaP material. D1 was conceptually representative of the clinically used implants. In D2, the titanium structure was simplified in terms of geometry in order to facilitate the manufacturing. The mechanical response of the implants was evaluated in quasi-static compression, and in impact using a drop-tower. Similar peak loads were obtained for the two designs, at the two loading rates: 808 ± 29 N and 852 ± 34 for D1, and 840 ± 40 N and 814 ± 13 for D2. A strain rate dependency was demonstrated for both designs, with a higher stiffness in the impact test. Furthermore, the titanium in the implant fractured in the quasi-static test (to failure) but not in the impact test (to 5.75 J) for D1. For D2, the displacement at peak load was significantly lower in the impact test than in the quasi-static test. The main difference between the designs was seen in the quasi-static test results where the deformation zones, i.e. notches in the titanium structure between the CaP tiles, in D1 likely resulted in a localization of the deformation, compared to in D2 (which did not have deformation zones). In the impact test, the only significant difference between the designs was a higher maximum displacement of D2 than of D1. In comparison with other reported mechanical tests on osteoconductive ceramic-based cranial implants, the CaP-Ti implant demonstrates the highest reported strength in quasi-static compression. In conclusion, the titanium structure seems to make the CaP-Ti implant capable of cerebral protection in impact situations like the one tested in this study.
Collapse
Affiliation(s)
- Susanne Lewin
- Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Uppsala, Sweden.
| | - Jonas Åberg
- Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | | | - Håkan Engqvist
- Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | | | - Caroline Öhman-Mägi
- Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Uppsala, Sweden
| | | | - Cecilia Persson
- Div. of Applied Materials Science, Dept. of Engineering Sciences, Uppsala University, Uppsala, Sweden
| |
Collapse
|
18
|
Wu D, Isaksson P, Ferguson SJ, Persson C. Young's modulus of trabecular bone at the tissue level: A review. Acta Biomater 2018; 78:1-12. [PMID: 30081232 DOI: 10.1016/j.actbio.2018.08.001] [Citation(s) in RCA: 93] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 06/30/2018] [Accepted: 08/02/2018] [Indexed: 01/06/2023]
Abstract
The tissue-level Young's modulus of trabecular bone is important for detailed mechanical analysis of bone and bone-implant mechanical interactions. However, the heterogeneity and small size of the trabecular struts complicate an accurate determination. Methods such as micro-mechanical testing of single trabeculae, ultrasonic testing, and nanoindentation have been used to estimate the trabecular Young's modulus. This review summarizes and classifies the trabecular Young's moduli reported in the literature. Information on species, anatomic site, and test condition of the samples has also been gathered. Advantages and disadvantages of the different methods together with recent developments are discussed, followed by some suggestions for potential improvement for future work. In summary, this review provides a thorough introduction to the approaches used for determining trabecular Young's modulus, highlights important considerations when applying these methods and summarizes the reported Young's modulus for follow-up studies on trabecular properties. STATEMENT OF SIGNIFICANCE The spongy trabecular bone provides mechanical support while maintaining a low weight. A correct measure of its mechanical properties at the tissue level, i.e. at a single-trabecula level, is crucial for analysis of interactions between bone and implants, necessary for understanding e.g. bone healing mechanisms. In this study, we comprehensively summarize the Young's moduli of trabecular bone estimated by currently available methods, and report their dependency on different factors. The critical review of different methods with recent updates is intended to inspire improvements in estimating trabecular Young's modulus. It is strongly suggested to report detailed information on the tested bone to enable statistical analysis in the future.
Collapse
|
19
|
Kirillova A, Kelly C, Windheim N, Gall K. Bioinspired Mineral-Organic Bioresorbable Bone Adhesive. Adv Healthc Mater 2018; 7:e1800467. [PMID: 29938916 DOI: 10.1002/adhm.201800467] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 05/29/2018] [Indexed: 12/17/2022]
Abstract
Bioresorbable bone adhesives have potential to revolutionize the clinical treatment of the human skeletal system, ranging from the fixation and osteointegration of permanent implants to the direct healing and fusion of bones without permanent fixation hardware. Despite an unmet need, there are currently no bone adhesives in clinical use that provide a strong enough bond to wet bone while possessing good osteointegration and bioresorbability. Inspired by the sandcastle worm that creates a protective tubular shell around its body using a proteinaceous adhesive, a novel bone adhesive is introduced, based on tetracalcium phosphate and phosphoserine, that cures in minutes in an aqueous environment and provides high bone-to-bone adhesive strength. The new material is measured to be 10 times more adhesive than bioresorbable calcium phosphate cement and 7.5 times more adhesive than non-resorbable poly(methyl methacrylate) bone cement, both of which are standard of care in the clinic today. The bone adhesive also demonstrates chemical adhesion to titanium approximately twice that of its adhesion to bone, unlocking the potential for adherence to metallic implants during surrounding bony incorporation. Finally, the bone adhesive is shown to demonstrate osteointegration and bioresorbability over a 52-week period in a critically sized distal femur defect in rabbits.
Collapse
Affiliation(s)
- Alina Kirillova
- Department of Mechanical Engineering and Materials Science Edmund T. Pratt Jr., School of Engineering Duke University Durham NC 27708 USA
| | - Cambre Kelly
- Department of Mechanical Engineering and Materials Science Edmund T. Pratt Jr., School of Engineering Duke University Durham NC 27708 USA
| | - Natalia Windheim
- Department of Mechanical Engineering and Materials Science Edmund T. Pratt Jr., School of Engineering Duke University Durham NC 27708 USA
| | - Ken Gall
- Department of Mechanical Engineering and Materials Science Edmund T. Pratt Jr., School of Engineering Duke University Durham NC 27708 USA
| |
Collapse
|
20
|
Acciaioli A, Lionello G, Baleani M. Experimentally Achievable Accuracy Using a Digital Image Correlation Technique in measuring Small-Magnitude (<0.1%) Homogeneous Strain Fields. MATERIALS 2018; 11:ma11050751. [PMID: 29738441 PMCID: PMC5978128 DOI: 10.3390/ma11050751] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 05/04/2018] [Accepted: 05/04/2018] [Indexed: 11/16/2022]
Abstract
Measuring small-magnitude strain fields using a digital image correlation (DIC) technique is challenging, due to the noise-signal ratio in strain maps. Here, we determined the level of accuracy achievable in measuring small-magnitude (<0.1%) homogeneous strain fields. We investigated different sets of parameters for image processing and imaging pre-selection, based on single-image noise level. The trueness of DIC was assessed by comparison of Young’s modulus (E) and Poisson’s ratio (ν) with values obtained from strain gauge measurements. Repeatability was improved, on average, by 20–25% with experimentally-determined optimal parameters and image pre-selection. Despite this, the intra- and inter-specimen repeatability of strain gauge measurements was 5 and 2.5 times better than DIC, respectively. Moreover, although trueness was also improved, on average, by 30–45%, DIC consistently overestimated the two material parameters by 1.8% and 3.2% for E and ν, respectively. DIC is a suitable option to measure small-magnitude homogeneous strain fields, bearing in mind the limitations in achievable accuracy.
Collapse
Affiliation(s)
- Alice Acciaioli
- IRCCS-Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, 40136 Bologna, Italy.
| | - Giacomo Lionello
- IRCCS-Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, 40136 Bologna, Italy.
| | - Massimiliano Baleani
- IRCCS-Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, 40136 Bologna, Italy.
| |
Collapse
|
21
|
Persson J, Helgason B, Engqvist H, Ferguson SJ, Persson C. Stiffness and strength of cranioplastic implant systems in comparison to cranial bone. J Craniomaxillofac Surg 2018; 46:418-423. [DOI: 10.1016/j.jcms.2017.11.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 11/17/2017] [Accepted: 11/28/2017] [Indexed: 11/17/2022] Open
|
22
|
A novel strategy to enhance interfacial adhesion in fiber-reinforced calcium phosphate cement. J Mech Behav Biomed Mater 2017; 75:495-503. [DOI: 10.1016/j.jmbbm.2017.08.017] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2017] [Revised: 08/10/2017] [Accepted: 08/14/2017] [Indexed: 11/22/2022]
|
23
|
Liang T, Gao CX, Yang L, Saijilafu, Yang HL, Luo ZP. Deterioration of the mechanical properties of calcium phosphate cements with Poly (γ-glutamic acid) and its strontium salt after in vitro degradation. J Mech Behav Biomed Mater 2017; 75:190-196. [PMID: 28750300 DOI: 10.1016/j.jmbbm.2017.07.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Revised: 07/16/2017] [Accepted: 07/19/2017] [Indexed: 10/19/2022]
Abstract
The mechanical reliability of calcium phosphate cements has restricted their clinical application in load-bearing locations. Although their mechanical strength can be improved using a variety of strategies, their fatigue properties are still unclear, especially after degradation. The evolutions of uniaxial compressive properties and the fatigue behavior of calcium phosphate cements incorporating poly (γ-glutamic acid) and its strontium salt after different in vitro degradation times were investigated in the present study. Compressive strength decreased from the 61.2±5.4MPa of the original specimen, to 51.1±4.4, 42.2±3.8, 36.8±2.4 and 28.9±3.2MPa following degradation for one, two, three and four weeks, respectively. Fatigue life under same loading condition also decreased with increasing degradation time. The original specimens remained intact for one million cycles (run-out) under a maximum stress of 30MPa. After degradation for one to four weeks, the specimens were able to withstand maximum stress of 20, 15, 10 and 10MPa, respectively until run-out. Defect volume fraction within the specimens increased from 0.19±0.021% of the original specimen to 0.60±0.19%, 1.09±0.04%, 2.68±0.64% and 7.18±0.34% at degradation time of one, two, three and four weeks, respectively. Therefore, we can infer that the primary cause of the deterioration of the mechanical properties was an increasing in micro defects induced by degradation, which promoted crack initiation and propagation, accelerating the final mechanical failure of the bone cement. This study provided the data required for enhancing the mechanical reliability of the calcium phosphate cements after different degradation times, which will be significant for the modification of load-bearing biodegradable bone cements to match clinical application.
Collapse
Affiliation(s)
- Ting Liang
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China
| | - Chun-Xia Gao
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China
| | - Lei Yang
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China
| | - Saijilafu
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China
| | - Hui-Lin Yang
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China
| | - Zong-Ping Luo
- Orthopaedic Institute, Department of Orthopaedics, The First Affiliated Hospital, Soochow University, Suzhou, Jiangsu, China.
| |
Collapse
|