Vasiliadis AV, Giovanoulis V, Lepidas N, Bampis I, Servien E, Lustig S, Gunst S. Stress shielding in stemmed reverse shoulder arthroplasty: an updated review. SICOT J 2024; 10:37. [PMID: 39303143 DOI: 10.1051/sicotj/2024029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Accepted: 07/26/2024] [Indexed: 09/22/2024] Open
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) is popular for the treatment of degenerative glenohumeral joint disease. Bone remodeling around the humeral stem related to stress shielding (SS) has been described. This review focuses on the specific radiological characteristics, risk factors, and clinical consequences of SS in RSA. METHODS A meticulous review was conducted of articles published between 2013 and 2023. Data on the definition, risk factors, and clinical impact of stress shielding were recorded. RESULTS Twenty-eight studies describing 2691 patients who had undergone RSA were included. The mean age of patients ranged from 63 to 80 years with mean follow-up periods of 12 months to 9.6 years. The prevalence of SS reached up to 39% at a 2-year follow-up. Females and elderly are typically at higher risk due to osteopenia. SS was more frequent with the use of long stems(>100 mm) compared to short stems(<100 mm). Stem design, onlay or inlay, and neck-shaft-angle did not influence SS. Frontal misalignment and a high filling ratio are riskfactors for SS. Biological factors also contribute to SS, associated with scapular notching. No correlation was found between SS and clinical outcomes. CONCLUSIONS SS is common in patients with cementless implants after RSA, especially in female and elderly patients. It can be limited by implanting stems with a low diaphyseal filling-ratio, in correct coronal alignment. Risk factors for polyethylene debris, primarily scapular notching, should be avoided. The authors found no clinical consequences of stress shielding, but longer-term follow-up studies are required to confirm these findings.
Collapse
Affiliation(s)
- Angelo V Vasiliadis
- Department of Orthopaedic Surgery, St. Luke's Hospital, Panorama-Thessaloniki, 55236, Greece - Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, 69004, France
| | - Vasileios Giovanoulis
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, 69004, France
| | - Nikolaos Lepidas
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, 24 avenue Paul Santy, Lyon 69008, France
| | - Ioannis Bampis
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, 69004, France - Orthopaedics Department, Bioclinic, 11524 Athens, Greece
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, 69004, France - Interuniversity Laboratory of Biology of Mobility, LIBM, EA 7424, Claude Bernard Lyon 1 University, Lyon, 69008, France
| | - Sebastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, 69004, France - Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, Lyon, 69622, France
| | - Stanislas Gunst
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, 24 avenue Paul Santy, Lyon 69008, France
| |
Collapse
|
2
|
Takayama K, Ito H. Association between the canal filling ratio and bone resorption in trabecular metal stems in reverse total shoulder arthroplasty: a radiographic analysis using tomosynthesis. JSES Int 2024; 8:1077-1086. [PMID: 39280137 PMCID: PMC11401559 DOI: 10.1016/j.jseint.2024.05.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/18/2024] Open
Abstract
Background Several factors affect the incidence of osteopenia with cortical narrowing (CNO) in reverse shoulder arthroplasty. This study aimed to compare the incidence of CNO with different fixation methods (cemented or cementless) using a single implant (trabecular metal humeral stem) evaluated using tomosynthesis and to analyze the factors affecting the incidence of CNO for cementless stem fixation. Methods A total of 109 patients (cementless: 75 cases; cemented: 34 cases) who underwent reverse total shoulder arthroplasty were included in this study. The patients were divided into 2 groups (cementless or cemented), and the incidence of CNO was compared. In addition, patients in the cementless group were divided into 2 groups (canal filling ratio [CFR] of ≥ 0.7 or < 0.7), the incidence of CNO was compared, and the Cramer's coefficient of association between CNO and CFR > 0.7 (and 0.8) was calculated. Results No significant difference was observed in the incidence of CNO between the cementless and cemented groups (7/75 vs. 3/35, P value = 1.0). The association between CNO and the CFR using Cramer's coefficient of association showed that there were few correlations (coefficient: 0.14, P value = .59). Conclusion Cementless reverse total shoulder arthroplasty with a trabecular metal stem has a similar low incidence of CNO as cemented fixation, and the incidence of CNO with a trabecular metal stem was lower than that reported in previous studies. A CFR > 0.7 was not associated with the incidence of CNO.
Collapse
Affiliation(s)
| | - Hiromu Ito
- Department of Orthopaedics, Kurashiki Central Hospital, Japan
| |
Collapse
|
3
|
Ippolito G, Lanzetti RM, Ferraro S, Pace V, Damo M, Surace MF, Giai Via ADE, Crivellaro M, De Marinis G, Spoliti M. Comparison of Short Uncemented Metaphyseal Stem and Long-Stem Reverse Shoulder Arthroplasty in Proximal Humerus Fractures: Preliminary Study at 2-Year Follow-Up. J Clin Med 2024; 13:4665. [PMID: 39200807 PMCID: PMC11355206 DOI: 10.3390/jcm13164665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 07/29/2024] [Accepted: 07/30/2024] [Indexed: 09/02/2024] Open
Abstract
Introduction: In the last few years, short metaphyseal-socket prosthetic humeral stems have been introduced for reverse shoulder arthroplasty (RSA). A short stem may have advantages in humeral force distribution, reducing shear stress and preserving bone stock, keeping in mind the need for possible future revision surgery. The main objective of our study was to validate the use of a short stem prosthesis in the surgical treatment of humeral fractures by comparing clinical and radiological outcomes of our studied implant with those obtained with the use of traditional long-stem implants. Methods: In this multicentric, controlled prospective study, 125 patients with proximal three- or four-fragment humerus fractures were selected and treated with RSA. A short stem was used in group A (n = 53, mean age: 75.6 ± 5.6 years old), and a long stem was used in group B (n = 72, mean age: 71.76 ± 3). Active range of motion (ROM), Constant score (CS), Quick DASH, American Shoulder and Elbow Surgeons Shoulder (ASES) score, and Visual Analog Scale (VAS) scores were collected and analyzed at 2 years mean follow-up, as well as humeral and glenoid bone resorption (sum Inoue scores and Sirveaux scores were used). Results: No statistically significant differences were observed between group A and B in ROM, Constant score (51.69 ± 15.8 vs. 53.46 ± 15.96, p > 0.05), Quick DASH (31.5 ± 21.81 vs. 28.79 ± 13.72, p = 0.85), ASES (82.53 ± 17.79 vs. 84.34 ± 15.24, p = 0.57), or the VAS (0.53 ± 1 vs. 0.56 ± 1.07, p = 0.14) at the final follow-up. No statistically significant differences were found in the radiographic parameters between the two groups. No statistically significant differences were found for the average degree of humeral and glenoid bone resorption either. Conclusions: The use of a short metaphyseal-socket stem can be considered a safe, effective, and feasible option in reverse shoulder arthroplasty for treating proximal humerus fractures. Our results are encouraging, with no statistically significant differences identified between the proposed treatment and traditional long stems.
Collapse
Affiliation(s)
- Giorgio Ippolito
- Trauma & Orthopaedic Department, Icot Hospital “Marco Pasquali”, 04100 Latina, Italy
| | - Riccardo Maria Lanzetti
- Orthopaedics and Traumatology Unit, Department of Emergeny and Acceptance, Azienda Ospedialiera San Camillo-Forlanini, 00152 Rome, Italy (M.S.)
| | | | - Valerio Pace
- Trauma & Orthopaedics Department, AOSP Terni, 05100 Terni, Italy
| | - Marco Damo
- Trauma & Orthopaedic Department, Icot Hospital “Marco Pasquali”, 04100 Latina, Italy
| | - Michele Francesco Surace
- Department of Biotechnology and Sciences for Life, University of Insubria, Cittiglio-Angera, 21100 Varese, Italy
| | - Alessio Davide Enrico Giai Via
- Orthopaedics and Traumatology Unit, Department of Emergeny and Acceptance, Azienda Ospedialiera San Camillo-Forlanini, 00152 Rome, Italy (M.S.)
| | - Michele Crivellaro
- Orthopaedic and Traumatology Department, Orthopaedic and Trauma Center, University of Turin, 10126 Turin, Italy
| | - Giancarlo De Marinis
- Trauma & Orthopaedic Department, Icot Hospital “Marco Pasquali”, 04100 Latina, Italy
| | - Marco Spoliti
- Orthopaedics and Traumatology Unit, Department of Emergeny and Acceptance, Azienda Ospedialiera San Camillo-Forlanini, 00152 Rome, Italy (M.S.)
| |
Collapse
|
4
|
Cho SH, Park CJ, Kim SJ, Lee KG, Baek GR, Chung MS, Hui AT, McGarry MH, Lee TQ, Jung S, Kim J, Kim YS. Varus-valgus alignment of humeral short stem in reverse total shoulder arthroplasty: does it really matter? J Shoulder Elbow Surg 2024; 33:1762-1770. [PMID: 38242527 DOI: 10.1016/j.jse.2023.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 11/15/2023] [Accepted: 11/19/2023] [Indexed: 01/21/2024]
Abstract
BACKGROUND The utilization of short humeral stems in reverse total shoulder arthroplasty has gained attention in recent times. However, concerns regarding the risk of misalignment during implant insertion are associated with their use. METHODS Eight fresh-frozen cadaveric shoulders were prepared for dissection and biomechanical testing. A bespoke humeral implant was fabricated to facilitate assessment of neutral, varus, and valgus alignments using a single stem, and 10° was established as the maximum permissible angle for misalignments. Shift in humerus position and changes in deltoid length attributable to misalignments relative to the neutral position were evaluated using a Microscribe 3DLx system. The impingement-free range of motion, encompassing abduction, adduction, internal rotation, and external rotation (ER), was gauged using a digital goniometer. The capacity for abduction was evaluated at maximal abduction angles under successive loading on the middle deltoid. A specialized traction system coupled with a force transducer was employed to measure anterior dislocation forces. RESULTS Relative to the neutral alignment, valgus alignment resulted in a more distal (10.5 ± 2.4 mm) and medial (8.3 ± 2.2 mm) translation of the humeral component, whereas the varus alignment resulted in the humerus shifting more superiorly (11.2 ± 1.3 mm) and laterally (9.9 ± 0.9 mm) at 0° abduction. The valgus alignment exhibited the highest abduction angle than neutral alignment (86.2°, P < .001). Conversely, the varus alignment demonstrated significantly higher adduction (18.4 ± 7.4°, P < .001), internal rotation (68.9 ± 15.0°, P = .014), and ER (45.2 ± 10.5°, P = .002) at 0° abduction compared to the neutral alignments. Anterior dislocation forces were considerably lower (23.8 N) in the varus group compared to the neutral group at 0°ER (P = .047). Additionally, abduction capability was markedly higher in varus alignment at low deltoid loads than the neutral alignment (5N, P = .009; 7.5 N, P = .007). CONCLUSIONS The varus position enhances rotational range of motion (ROM) but increases instability, while the valgus position does not significantly impact ROM or instability compared to the neutral position.
Collapse
Affiliation(s)
- Sung-Hyun Cho
- Department of Orthopedic Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Chan-Joo Park
- Department of Orthopedic Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Sang-Jae Kim
- Department of Orthopedic Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyoung-Geun Lee
- Department of Orthopedic Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea
| | - Gyu Rim Baek
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Min-Shik Chung
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Aaron T Hui
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Michelle H McGarry
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Thay Q Lee
- Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA
| | - Sungwook Jung
- Central R&D Center, Corentec Co., Ltd., Seoul, Republic of Korea
| | - Jaewon Kim
- Central R&D Center, Corentec Co., Ltd., Seoul, Republic of Korea
| | - Yang-Soo Kim
- Department of Orthopedic Surgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Montemaggi P, Lo EY, Ouseph A, Lund J, Krishnan SG. Cementless reverse total shoulder arthroplasty implantation with humeral matchstick autograft augmentation: early radiographic outcomes. J Shoulder Elbow Surg 2024; 33:e422-e428. [PMID: 38218403 DOI: 10.1016/j.jse.2023.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 11/14/2023] [Accepted: 11/19/2023] [Indexed: 01/15/2024]
Abstract
BACKGROUND Humeral-sided complications account for up to 21% of all revision reverse total shoulder arthroplasty (RTSA) surgeries. Stress shielding with large bulky stems can lead to proximal bone resorption per Wolff law, complicating further surgeries. Previously published studies suggest that lowering the metaphyseal implant fill ratio can lead to fewer adaptive radiographic changes and decreased bone resorption. Inspired by these studies, cementless primary RTSA implantation technique with humeral matchstick autografts was proposed to augment cementless humeral constructs, foster the use of a smaller size stem, and create primary stability of the humeral implant even in osteoporotic or in-between size medullary canals. In this study, retrospective review of this cementless RTSA technique with short-term radiographic evaluation was performed. METHODS Forty-six nonconsecutive patients underwent primary RTSA with a short-stem cementless prosthesis (Stryker Ascend Flex) augmented by matchstick bone grafting from January to July 2020. Patient demographics were recorded, and follow-up radiographs were retrospectively reviewed to assess metaphyseal fill ratios and incidence of stress shielding at minimum 1-year follow-up. Discrepancies between templated and final stem sizes were recorded, along with all intraoperative and postoperative complications. RESULTS Of the 46 patients originally identified, there were 5 men and 41 women with a mean age of 71 years (standard deviation [SD] 7, range 53-88). Mean templated stem size was 4 (SD 2, range 1-8), whereas the mean final implant size was 2 (SD 1, range 1-3). Mean fill ratios were 0.76 (SD 0.06, range 0.54-0.89) along the metaphysis and 0.67 (SD 0.09, range 0.49-0.83) along the diaphysis. There were no intraoperative humeral fractures from implantation. All patients were available for radiographic follow-up with a mean of 19 months (SD 8, range 12-40). There were 3 cases (7%) of proximal humeral stress shielding, with average fill ratios of 0.857 and 0.807 in the metaphysis and diaphysis, respectively. There were 3 patients (7%) who underwent revision surgeries for baseplate failure and periprosthetic humeral fracture. There were no cases of early humeral loosening. DISCUSSION Matchstick autograft humeral augmentation is a simple, promising surgical technique with low intraoperative complication rates and good short-term radiographic outcomes. When the implant fill ratio is successfully reduced, there is a possible lower risk of humeral stress shielding. The authors believe this technique can help maximize implant stability in cementless shoulder arthroplasty and preserve humeral bone stock for future revision surgeries.
Collapse
Affiliation(s)
| | - Eddie Y Lo
- The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA.
| | - Alvin Ouseph
- The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA
| | - Julia Lund
- The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA
| | - Sumant G Krishnan
- The Shoulder Center Research, Baylor Scott and White Research Institute, Dallas, TX, USA; The Shoulder Service, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX, USA
| |
Collapse
|
6
|
Twomey-Kozak J, Adu-Kwarteng K, Lunn K, Briggs DV, Hurley E, Anakwenze OA, Klifto CS. Recent Advances in the Design and Application of Shoulder Arthroplasty Implant Systems and Their Impact on Clinical Outcomes: A Comprehensive Review. Orthop Res Rev 2024; 16:205-220. [PMID: 39081796 PMCID: PMC11288362 DOI: 10.2147/orr.s312870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 07/11/2024] [Indexed: 08/02/2024] Open
Abstract
Purpose of Review This narrative review comprehensively aims to analyze recent advancements in shoulder arthroplasty, focusing on implant systems and their impact on patient outcomes. The purpose is to provide a nuanced understanding of the evolving landscape in shoulder arthroplasty, incorporating scientific, regulatory, and ethical dimensions. Recent Findings The review synthesizes recent literature on stemless implants, augmented glenoid components, inlay vs onlay configurations, convertible stems, and associated complications. Notable findings include improved patient-reported outcomes with stemless implants, variations in outcomes between inlay and onlay configurations, and the potential advantages of convertible stems. Additionally, the regulatory landscape, particularly the FDA's 510(k) pathway, is explored alongside ethical considerations, emphasizing the need for standardized international regulations. Summary Recent innovations in shoulder arthroplasty showcase promising advancements, with stemless implants demonstrating improved patient outcomes. The review underscores the necessity for ongoing research to address unresolved aspects and highlights the importance of a standardized regulatory framework to ensure patient safety globally. The synthesis of recent findings contributes to a comprehensive understanding of the current state of shoulder arthroplasty, guiding future research and clinical practices.
Collapse
Affiliation(s)
- John Twomey-Kozak
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Kwabena Adu-Kwarteng
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Kiera Lunn
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Damon Vernon Briggs
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Eoghan Hurley
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Oke A Anakwenze
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Christopher S Klifto
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
7
|
Claro R, Sousa A, Silva E, Barros LH. Outcomes of a cementless onlay short stem reverse shoulder arthroplasty in elderly patients: a comprehensive analysis of clinical and radiological findings. Arch Orthop Trauma Surg 2024; 144:2093-2099. [PMID: 38653836 PMCID: PMC11093792 DOI: 10.1007/s00402-024-05321-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 04/07/2024] [Indexed: 04/25/2024]
Abstract
OBJECTIVE The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE Level III; Retrospective Study.
Collapse
Affiliation(s)
- Rui Claro
- Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal.
- Shoulder Unit, Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal.
- Instituto de Ciências Biomédicas Abel Salazar da Universidade do Porto (ICBAS-UP), Porto, Portugal.
| | - Arnaldo Sousa
- Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal
| | - Eurico Silva
- Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal
- Shoulder Unit, Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal
| | - Luís Henrique Barros
- Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal
- Shoulder Unit, Department of Orthopedics, Centro Hospitalar Universitário de Santo António. Hospital de Santo António, Porto, Portugal
- Instituto de Ciências Biomédicas Abel Salazar da Universidade do Porto (ICBAS-UP), Porto, Portugal
| |
Collapse
|
8
|
Gunst S, Cloquell Y, Collotte P, Ioncu A, Haritinian EG, Nové-Josserand L. Medium-term clinical and radiographic outcomes of a cementless prosthesis with a 140° neck-shaft angle in reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:1075-1083. [PMID: 37777044 DOI: 10.1016/j.jse.2023.08.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 08/08/2023] [Accepted: 08/27/2023] [Indexed: 10/02/2023]
Abstract
BACKGROUND The design of humeral implants has evolved from the initial Grammont design, notably regarding the neck-shaft angle (NSA) and through the use of cementless prostheses. Stress shielding was frequently reported with cementless implants, the 2 main risk factors being humeral stem misalignment and high filling ratios. Our hypothesis was that standard length cementless stems with an NSA of 140° would facilitate good alignment with moderate filling ratios, thereby limiting stress shielding and ensuring good clinical outcomes. METHODS A single-center retrospective study was conducted of patients who underwent reverse total shoulder arthroplasty between January 2015 and August 2017, with at least 2 years' follow-up. Clinical evaluations included range of motion measurements and Constant and subjective shoulder values scores. Frontal alignment was assessed in terms of the angle (α) between axes of the stem and of the humerus. Filling ratios were measured in the metaphysis of the humerus, in the diaphysis, and at the distal end of the stem and considered excessive above 0.7. Stress shielding was evidenced radiographically by the observation of medial cortical narrowing, medial metaphysis thinning, lateral metaphysis thinning or under-the-baseplate osteolysis. RESULTS Eighty-two shoulders were included and 70 had radiographic follow-up data available. The mean patient age was 78 years and 63/81 patients (78%) were female. The mean follow-up time was 39 ± 7 months. The mean α angle was 1.4° ± 0.9° and was less than 5° in all cases. The mean metaphyseal, diaphyseal, and distal filling ratios were 0.61 ± 0.06, 0.70 ± 0.08, and 0.64 ± 0.09, respectively. The mean Constant score improved from 28 ± 11 preoperatively to 64 ± 14 at last follow-up. The mean subjective shoulder values score at last follow-up was 81 ± 12. Seventy-nine percent of patients (55/70) had at least 1 form of stress-shielding related, which were not associated with clinical outcomes, apart from lateral metaphysis thinning, which was associated with lower active anterior elevation (mean, 106° ± 30° vs. 126° ± 28°; P = .01) and lower Constant scores (mean, 56 ± 17 vs. 65 ± 14; P = .06). CONCLUSION The use of cementless reverse shoulder prostheses with a NSA of 140° was associated with good clinical outcomes at 2 years' follow-up. The prosthesis stem was correctly aligned with the humeral axis and the filling ratios were <0.7 in all cases. Stress-shielding was common but, apart from lateral metaphysis thinning, this had no impact on clinical outcomes.
Collapse
Affiliation(s)
- Stanislas Gunst
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France; IFSTTAR, University Lyon, Claude Bernard Lyon 1 University, Lyon, France
| | - Yannick Cloquell
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Philippe Collotte
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Adrian Ioncu
- Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Emil George Haritinian
- Carol Davila University of Medicine and Pharmacy, Foișor Orthopaedic Hospital, Bucharest, Romania
| | | |
Collapse
|
9
|
Lee HJ, Kim BK, Dan J. Does the proximal humeral bone quality influence alignment after reverse total shoulder arthroplasty with short humeral stems? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2137-2145. [PMID: 38557891 DOI: 10.1007/s00590-024-03909-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 03/07/2024] [Indexed: 04/04/2024]
Abstract
PURPOSE When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality. METHODS RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem. RESULTS The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05). CONCLUSION The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.
Collapse
Affiliation(s)
- Ho-Jae Lee
- Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea
| | - Byung-Kook Kim
- Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea
| | - Jinmyoung Dan
- Department of Orthopaedic Surgery, Gumi CHA Medical Center, CHA University School of Medicine, Sinsi-ro 10gil 12, Kyungsangbuk-do, Gumi-Si, 39314, Republic of Korea.
| |
Collapse
|
10
|
Nové-Josserand L, Nerot C, Colotte P, Guery J, Godenèche A. Reverse shoulder arthroplasty for primary glenohumeral osteoarthritis: significantly different characteristics and outcomes in shoulders with intact vs. torn rotator cuff. J Shoulder Elbow Surg 2024; 33:850-862. [PMID: 37633591 DOI: 10.1016/j.jse.2023.07.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/11/2023] [Accepted: 07/21/2023] [Indexed: 08/28/2023]
Abstract
PURPOSE To compare outcomes of reverse shoulder arthroplasty (RSA) for primary osteoarthritis (OA) with and without rotator cuff (RC) tears to those with secondary OA due to RC tears. METHODS We reviewed records of all patients who received RSA for primary OA or secondary OA. All patients had preoperative radiographs, computed tomographic arthrography (CTA), and/or magnetic resonance imaging (MRI) scans of their shoulders to assess their etiology, glenoid morphology, and fatty infiltration. Pre- and postoperative (at minimum follow-up of 2 years) Constant scores and range of motion were compared between patients who had RSA for primary OA with and without RC tears to those with secondary OA due to RC tears. RESULTS Of the initial cohort of 605 shoulders (583 patients), 153 were lost to follow-up (25.3%), 25 required revision with implant removal (4.1%), and 13 died of causes unrelated to the surgery (2.1%), and left a final cohort of 414 patients. Of the final cohort, 97 had primary OA with intact RC, 62 had primary OA with RC tears, and 255 had secondary OA. Postoperative Constant scores were significantly higher for primary OA with intact RC (73.8 ± 14.3), compared with both primary OA with RC tears (66.1 ± 14.6, P < .001) and secondary OA (64.1 ± 14.8, P < .001). There were no differences in pre- or postoperative scores between primary OA with RC tears and secondary OA. CONCLUSION At 2 or more years following RSA, Constant scores were significantly higher for primary OA with intact RC, compared to either primary OA with RC tears or secondary OA, whereas there were no differences in pre- or postoperative scores of shoulders that had primary OA with RC tears vs. secondary OA. The authors recommend distinguishing primary OA with intact RC from primary OA with RC tears, as the two have considerably different characteristics and prognosis following RSA.
Collapse
Affiliation(s)
- Laurent Nové-Josserand
- Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Ramsay Santé, Lyon, France; SoFEC - French Shoulder and Elbow Society, Paris, France
| | - Cecile Nerot
- SoFEC - French Shoulder and Elbow Society, Paris, France; Reims University Hospital, Reims, France
| | - Philippe Colotte
- Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Ramsay Santé, Lyon, France; SoFEC - French Shoulder and Elbow Society, Paris, France
| | - Jacques Guery
- SoFEC - French Shoulder and Elbow Society, Paris, France; Polyclinique du Val de Loire, ELSAN, Nevers, France
| | | |
Collapse
|
11
|
Bischofreiter M, Sacan E, Gattringer M, Gruber MS, Breulmann FL, Kindermann H, Heuberer P, Mattiassich G, Ortmaier R. The Value of Computed Tomography-Based Planning in Shoulder Arthroplasty Compared to Intra-/Interobserver Reliability of X-ray Planning. J Clin Med 2024; 13:2022. [PMID: 38610787 PMCID: PMC11012767 DOI: 10.3390/jcm13072022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 03/24/2024] [Accepted: 03/27/2024] [Indexed: 04/14/2024] Open
Abstract
Background: Reversed total shoulder arthroplasty (RTSA) is an established surgery for many pathologies of the shoulder and the demand continues to rise with an aging population. Preoperative planning is mandatory to support the surgeon's understanding of the patient's individual anatomy and, therefore, is crucial for the patient's outcome. Methods: In this observational study, we identified 30 patients who underwent RTSA with two- and three-dimensional preoperative planning. Each patient underwent new two-dimensional planning from a medical student and an orthopedic resident as well as through a mid-volume and high-volume shoulder surgeon, which was repeated after a minimum of 4 weeks. The intra- and interobserver reliability was then analyzed and compared to the 3D planning and the implanted prosthesis. The evaluated parameters were the size of the pegged glenoid baseplate, glenosphere, and humeral short stem. Results: The inter-rater reliability showed higher deviations in all four raters compared to the 3D planning of the base plate, glenosphere, and shaft. The intra-rater reliability showed a better correlation in more experienced raters, especially in the planning of the shaft. Conclusions: Our study shows that 3D planning is more accurate than traditional planning on plain X-rays, despite experienced shoulder surgeons showing better results in 2D planning than inexperienced ones.
Collapse
Affiliation(s)
- Martin Bischofreiter
- Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 5020 Salzburg, Austria
- Department of Orthopedic and Trauma Surgery, Clinic Diakonissen Schladming, 8970 Schladming, Austria
| | - Edanur Sacan
- Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 5020 Salzburg, Austria
| | - Michael Gattringer
- Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 5020 Salzburg, Austria
| | - Michael S. Gruber
- Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 5020 Salzburg, Austria
| | - Franziska L. Breulmann
- Department of Orthopedic Sports Medicine, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany
| | - Harald Kindermann
- Department of Marketing and Electronic Business, University of Applied Sciences Upper Austria, 4400 Steyr, Austria
| | | | - Georg Mattiassich
- Department of Orthopedic and Trauma Surgery, Clinic Diakonissen Schladming, 8970 Schladming, Austria
| | - Reinhold Ortmaier
- Department of Orthopedic Surgery, Ordensklinikum Barmherzige Schwestern Linz, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, 5020 Salzburg, Austria
| |
Collapse
|
12
|
Yokoya S, Harada Y, Sumimoto Y, Kikugawa K, Natsu K, Nakamura Y, Nagata Y, Negi H, Watanabe C, Adachi N. Factors affecting stress shielding and osteolysis after reverse shoulder arthroplasty: A multicenter study in a Japanese population. J Orthop Sci 2024; 29:521-528. [PMID: 36710212 DOI: 10.1016/j.jos.2023.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 12/11/2022] [Accepted: 01/05/2023] [Indexed: 01/29/2023]
Abstract
BACKGROUND Stress shielding and osteolysis around the humeral stem after reverse shoulder arthroplasty causes loosening and periprosthetic fractures and reduces bone stock during revision surgery. In Japanese patients, who have relatively small bodies, different characteristics may exist regarding the occurrence of these changes compared with the characteristics of Westerners, who have relatively larger frames. The purpose of this multicenter study was to investigate the incidence and clarify the predictors of stress shielding and osteolysis in Japanese individuals who underwent reverse shoulder arthroplasty. METHODS The occurrence of stress shielding and osteolysis was investigated in 135 shoulders that had undergone reverse shoulder arthroplasty at least 2 years prior in five Japanese hospitals. During post-surgical follow-up, which was conducted every 3 months, the locations of the stress shielding occurrences, such as cortical thinning and osteopenia (which primarily occurred in zones 1, 2, and 7, where 1 is the greater tuberosity and 7 is the calcar part), spot weld, and condensation lines, were recorded. Cases without any abnormal findings on radiographs obtained up to ≥2 years after surgery were regarded as having no abnormalities. Finally, the predictors of cortical thinning and proximal humeral osteolysis were assessed using univariate and multivariate regression analyses. RESULTS Cortical thinning and osteopenia occurred in 68 shoulders, a condensation line occurred in 37 shoulders, and spot weld occurred in 23 shoulders. In particular, greater tuberosity and calcar osteolysis occurred in 40 and 47 shoulders, respectively. Long stem, cementless stem, and a larger proximal filling ratio were independent predictors of cortical thinning and osteopenia, whereas a cementless stem, larger metaphysis diameter, and a larger proximal filling ratio were associated with proximal humeral osteolysis. CONCLUSIONS The predictors of stress shielding and osteolysis included the use of long stems, cementless stems, larger proximal filling ratios, and larger metaphysis diameters. LEVEL OF EVIDENCE retrospective comparative study (Level III).
Collapse
Affiliation(s)
- Shin Yokoya
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Japan.
| | - Yohei Harada
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Japan
| | - Yasuhiko Sumimoto
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Japan; Department of Orthopaedic Surgery, Mazda Hospital, Japan
| | | | - Koji Natsu
- Department of Orthopaedic Surgery, Hiroshima City Hiroshima Citizens Hospital, Japan
| | | | - Yoshihiko Nagata
- Department of Orthopaedic Surgery, Hiroshima-Nishi Medical Center, Japan
| | - Hiroshi Negi
- Department of Orthopaedic Surgery, Hiroshima-Nishi Medical Center, Japan
| | | | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical & Health Sciences, Hiroshima University, Japan
| |
Collapse
|
13
|
Goñalons-Giol F, Ventura-Parellada C, Gàmez-Baños F, Mora-Guix JM. Stress shielding: short-term radiological results of the reverse shoulder arthroplasty with an anatomic proximal coated stem in proximal humeral fractures. Arch Orthop Trauma Surg 2024; 144:783-790. [PMID: 38141095 DOI: 10.1007/s00402-023-05169-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/27/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE This study aims to determine the stress shielding and other radiological outcomes of patients who underwent an uncemented reverse shoulder arthroplasty (RSA) with an anatomic proximal coated stem for complex proximal humeral fractures (PHF) with 3 or 4 parts at 2 years postoperatively. METHODS 37 shoulders underwent an uncemented RSA for PHF from November 2015 to February 2019 and were followed up for 2 years. A radiographic assessment of stress shielding, filling ratio, stem stability (radiolucent lines/subsidence/alignment), tuberosity healing and notch was performed. RESULTS The mean age at the time of surgery was 72 years (range, 61-85). Stress shielding was appreciated in 31 shoulders (83.8%). The most important characteristic of stress shielding is cortical resorption: Grade 3 resorption occurred in 3 shoulders (8.1%) and grade 4 in 23 (62.2%) as per the grading system defined by Inoue et al. (Inoue et al. in J Shoulder Elbow Surg 26:1984-1989, 2017). A high occurrence of bone resorption was observed in Gruen zones 2 (Lateral Stress shielding) and 7 (Medial Stress shielding). The mean distal filling ratio in patients without stress shielding was 78,48(SD 14,9), whereas in patients with stress shielding, it was slightly higher with a mean of 81,68% (SD 4,89). Tuberosity healing was found in 94.6% (35/37) of the shoulders. No patient had any radiolucent line. No notch was observed. CONCLUSION At short-term follow-up, a high rate of tuberosity healing was achieved (94.6%) even though stress shielding was found in 83.8% (31/37) of the shoulders. Bone resorption was most frequently observed externally at zone 2 (Lateral stress shielding) and internally at zone 7 (Medial stress shielding). A higher filling ratio was associated with an increased occurrence of stress shielding. The uncemented anatomic humeral component did not result in early loosening. LEVEL OF EVIDENCE IV; Case Series; Treatment study.
Collapse
Affiliation(s)
- Francesc Goñalons-Giol
- Department of Orthopaedic Surgery, Hospital Consorci Sanitari de Terrassa, Terrassa, Spain.
| | | | - Ferran Gàmez-Baños
- Department of Orthopaedic Surgery, Hospital Consorci Sanitari de Terrassa, Terrassa, Spain
| | - Jose María Mora-Guix
- Department of Orthopaedic Surgery, Hospital Consorci Sanitari de Terrassa, Terrassa, Spain
| |
Collapse
|
14
|
Kramer M, Olach M, Zdravkovic V, Manser M, Raiss P, Jost B, Spross C. The effects of length and width of the stem on proximal humerus stress shielding in uncemented primary reverse total shoulder arthroplasty. Arch Orthop Trauma Surg 2024; 144:663-672. [PMID: 38010377 PMCID: PMC10822783 DOI: 10.1007/s00402-023-05129-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Accepted: 11/01/2023] [Indexed: 11/29/2023]
Abstract
INTRODUCTION To preserve humeral bone during RTSA, stems have been made shorter and cement avoided whenever possible. However, with the increased use of uncemented RTSA, a phenomenon comparable to the stress shielding of the hip has been described for the proximal humerus. The aim of this study was to investigate the influence of stem length and width on proximal humeral bone resorption after primary uncemented RTSA. MATERIALS AND METHODS The prospective shoulder arthroplasty database of our institution was reviewed for all primary uncemented RTSAs from 2017 to 2020 in osteoarthritis and cuff tear arthropathy cases with > 2-year follow-up. We compared the clinical and the radiographic 2-year outcome of the short and standard length stems of the same prosthesis design. This allowed us to assess the effects of stem length and width with regard to stress shielding. Furthermore, we defined a cut-off value for the filling ratios to prevent stress shielding. RESULTS Fifty patients were included in the analysis, nineteen were in the short stem group (SHORT) and thirty-one in the standard stem group (STANDARD). After 2 years, SHORT showed a relative Constant Score of 91.8% and STANDARD of 98.3% (p = 0.256). Stress shielding was found in 4 patients (21%) in SHORT and in 16 patients (52%) in STANDARD (p = 0.03); it occurred more frequently in patients with higher humeral filling ratios (p < 0.05). The calculated cut-off to prevent stress shielding was 0.7 (± 0.03) for the metaphyseal and distal filling ratio. CONCLUSION While short and standard stems for RTSA have good results after 2 years, we found a significant negative effect of higher length and width of the stem with regard to stress shielding. Even though the clinical effects of stress shielding have to be assessed, short stems should be chosen with a filling ratio at the metaphyseal and distal position below 0.7. LEVEL OF EVIDENCE (A RETROSPECTIVE CASE-CONTROL STUDY) III.
Collapse
Affiliation(s)
- Manuel Kramer
- Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland.
| | - Martin Olach
- Orthopaedic Surgery and Traumatology, Spital Wil, SRFT, St. Gallen, Switzerland
| | - Vilijam Zdravkovic
- Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Melanie Manser
- Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Patric Raiss
- OCM (Orthopädische Chirurgie München) Clinic, Munich, Germany
| | - Bernhard Jost
- Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Christian Spross
- Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| |
Collapse
|
15
|
Larose G, Aibinder WR, Greene AT, Roche CP, Grey S, Faber KJ, Routman H, Antuña S, Wright T, Flurin PH, Zuckerman JD, Virk MS. Two-year minimum survivorship and radiographic analysis of a pressfit short humeral stem for total shoulder arthroplasty. JSES Int 2024; 8:191-196. [PMID: 38312300 PMCID: PMC10837737 DOI: 10.1016/j.jseint.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2024] Open
Abstract
Background Newer generation humeral stem designs in total shoulder arthroplasty (TSA) are trending towards shorter lengths and uncemented fixation. The goal of this study is to report a 2-yr minimum clinical and radiographic outcomes of an uncemented short-stem press-fit humeral stem in anatomic total shoulder arthroplasty (ATSA) and reverse total shoulder arthroplasty (RTSA). Methods A retrospective multicenter database review was performed of all patients who received an uncemented short-length press-fit humeral stem (Equinoxe Preserve humeral stem, Exactech, Inc., Gainesville, FL, USA) in ATSA and RTSA with a minimum two-year follow-up. The primary outcome was the prevalence of humeral stems at risk of radiographic loosening. Secondary outcomes included evaluation of functional outcome scores and prevalence of revision TSA for humeral stem loosening. Two blinded observers performed radiographic analyses, which included humeral stem alignment, canal filling ratio, radiolucent lines, stress shielding (calcar and greater tuberosity), and changes in component position (subsidence and stem shift). At risk stems were defined by the presence of one or more of the following: humeral stem with shifting or subsidence, scalloping of the humeral cortex, or radiolucent lines measuring 2 mm or greater in 3 or more zones. Results 287 patients (97 ATSA and 190 RTSA) were included in this study. The mean follow-up was 35.9 (±6.1) months. There were significant improvements for all functional outcome scores (P < .05), range of motion (P < .05), and visual analogue pain scale pain (P < .05). The prevalence of humeral stem at risk of radiographic loosening was 1% in the ATSA group (1/97) and 18.4% in the RTSA group (35/190). Calcar resorption was seen in 34% of ATSA and 19% of RTSA, with severe resorption in 12.4% of ATSA and only 3.2% of RTSA. Greater tuberosity resorption was present in 3.1% of ATSA and 7.9% of RTSA. The mean canal filling ratio was 50.2% (standard deviation 11.2%). Using logistic regression, a significant positive correlation between canal filling ratio and stress shielding (P < .01) was seen for both calcar and tuberosity stress shielding. The revision surgery rate was 0% in ATSA compared to 1.6% in RTSA. Conclusion This retrospective study demonstrates a low revision rate and low prevalence of humeral stems at risk of radiographic loosening at two years with a press-fit short-stem humeral design in ATSA. Physiologic subsidence of humeral stems can account for higher prevalence of humeral stems at radiographic risk of loosening in RTSA compared to ATSA.
Collapse
Affiliation(s)
- Gabriel Larose
- Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| | - William R Aibinder
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, USA
| | | | | | - Sean Grey
- Orthopedic and Spine Center of The Rockies, Fort Collins, CO, USA
| | | | - Howard Routman
- Palm Beach Shoulder Service at HCA Atlantis Orthopedics, Palm Beach, FL, USA
| | | | | | | | - Joseph D Zuckerman
- Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| | - Mandeep S Virk
- Department of Orthopedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA
| |
Collapse
|
16
|
Vegas A, Cannon D, Lewis S, Glener J, Mekkawy KL, Rodriguez HC, Schodlbauer DF, Levy JC. Impact of humeral stem length on calcar resorption in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:130-138. [PMID: 37419442 DOI: 10.1016/j.jse.2023.05.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 05/08/2023] [Accepted: 05/28/2023] [Indexed: 07/09/2023]
Abstract
BACKGROUND Use of standard-length anatomic total shoulder (TSA) humeral stems has been associated with high rates of medial calcar bone loss. Calcar bone loss has been attributed to stress shielding, debris-induced osteolysis, and undiagnosed infection. Short stem and canal-sparing humeral components may provide more optimal stress distribution and thus lower rates of calcar bone loss related to stress shielding. The purpose of this study is to determine whether implant length will affect the rate and severity of medial calcar resorption. METHODS A retrospective review was performed on TSA patients treated with three different-length humeral implants (canal-sparing, short, and standard-length designs). Patients were matched 1:1:1 based on both gender and age (±4 years), resulting in 40 patients per cohort. Radiographic changes in medial calcar bone were evaluated and graded on a 4-point scale, from the initial postoperative radiographs to those at 3 months, 6 months, and 12 months. RESULTS The presence of any degree of medial calcar resorption demonstrated an overall rate of 73.3% at one year. At 3 months, calcar resorption was observed in 20% of the canal-sparing cohort, while the short and standard designs demonstrated resorption in 55% and 52.5%, respectively (P = .002). At 12 months, calcar resorption was seen in 65% of the canal-sparing design, while both the short and standard designs had a 77.5% rate of resorption (P = .345). The severity of calcar resorption for the canal-sparing cohort was significantly lower at all time points when compared to the short stem (3 months, P = .004; 6 months, P = .003; 12 months, P = .004) and at 3 months when compared to the standard-length stem (P = .009). CONCLUSION Patients treated with canal-sparing TSA humeral components have significantly lower rates of early calcar resorption with less severe bone loss when compared to patients treated using short and standard-length designs.
Collapse
Affiliation(s)
- Austin Vegas
- Department of Orthopedic Surgery, Larkin Community Hospital, South Miami, FL, USA
| | - Dylan Cannon
- Department of Orthopaedic Surgery, Oklahoma University, Oklahoma City, OK, USA
| | - Steven Lewis
- Holy Cross Orthopedic Institute, Fort Lauderdale, FL, USA
| | - Julie Glener
- Holy Cross Orthopedic Institute, Fort Lauderdale, FL, USA
| | | | - Hugo C Rodriguez
- Department of Orthopedic Surgery, Larkin Community Hospital, South Miami, FL, USA
| | - Daniel F Schodlbauer
- Levy Shoulder Center at Paley Orthopedic and Spine Institute, Boca Raton, FL, USA
| | - Jonathan C Levy
- Levy Shoulder Center at Paley Orthopedic and Spine Institute, Boca Raton, FL, USA.
| |
Collapse
|
17
|
Nakazawa K, Manaka T, Hirakawa Y, Ito Y, Iio R, Oi N, Nakamura H. Bone mineral density around cementless short stems after reverse shoulder arthroplasty: changes over time and its relationship to stem positioning. JSES Int 2024; 8:119-125. [PMID: 38312281 PMCID: PMC10837704 DOI: 10.1016/j.jseint.2023.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2024] Open
Abstract
Background There are numerous reports of bone adaptation observed on plain radiography studies after the use of cementless short stems in reverse shoulder arthroplasty. However, reports on changes in bone mineral density (BMD) around the stem using dual-energy X-ray absorptiometry (DEXA) are prominently absent. In the present study, we measured BMD around the stem using DEXA and investigated changes over time from postoperative year 1 to year 2. Additionally, the relationship between BMD changes, filling ratio, and stem alignment was examined. Methods Forty-seven patients with short cementless stems who could be assessed via DEXA at 1-2 years postoperatively were included. After dividing the zones around the stem into 5, the BMD in each zone was measured, in addition to BMD changes and amount of change from postoperative year 1 to year 2. The relationship between filling ratio and stem alignment on postoperative plain radiography was assessed. Results A significant decrease in BMD in zone 3 was observed between postoperative year 1 and year 2 (P = .02). Regarding filling ratio and stem alignment, a negative correlation between valgus stem alignment and BMD change observed in zone 1 (r = -0.470, P < .01). In addition, stem valgus greater than 6° correlated with a significant decrease in BMD in zone 1. (P = .01). No significant differences were found in the other zones. Furthermore, there was no correlation between filling ratio and BMD change. Conclusion In reverse shoulder arthroplasty cementless short stems, changes that that occurred between postoperative year 1 to year 2 demonstrated a decrease in BMD in zone 3. In addition, a decrease in BMD in zone 1 was observed with a stem alignment of valgus 6° or higher, suggesting that stem alignment within valgus 6° is required to prevent a decrease in BMD.
Collapse
Affiliation(s)
- Katsumasa Nakazawa
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | - Tomoya Manaka
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | | | - Yoichi Ito
- Osaka Shoulder Center, Ito Clinic, Osaka, Japan
| | - Ryosuke Iio
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| | - Naoki Oi
- Osaka Shoulder Center, Ito Clinic, Osaka, Japan
| | - Hiroaki Nakamura
- Department of Orthopaedic Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
18
|
Soma D, Ichiseki T, Ueda S, Sakurai M, Kawahara N. Radiographic Evaluation and Changes in Bone Density of the Humeral Side after Reverse Total Shoulder Arthroplasty. J Clin Med 2023; 12:7698. [PMID: 38137767 PMCID: PMC10743489 DOI: 10.3390/jcm12247698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 12/11/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023] Open
Abstract
After artificial joint surgery, bone density may decrease around the artificial joint; thus, postoperative bone density evaluation around the artificial joint is crucial. We investigated changes in bone mineral density and performed radiographic evaluation around the stem after reverse shoulder arthroplasty (RSA) surgery in 17 males (18 shoulders) and 19 females (19 shoulders), aged >65 years, with >1-year follow-up. In total, 20 and 17 cases involved massive rotator cuff tears and rotator cuff tear arthropathy, respectively. The Comprehensive Reverse Shoulder System (Standard Ingrowth) was used for all cases and cement was used in eight patients due to bone fragility. We examined lucent lines, loosening, bone resorption, and spot welds in non-cemented cases using plain radiography and postoperative bone density changes around the stem using dual-energy X-ray absorptiometry (DEXA). Lucent lines and bone resorption occurred in 5 (13.5%) and 19 (51.4%) shoulders, respectively. No loosening occurred. Compared to stem bone density at 2 weeks postoperatively, the decrease rate was the largest in the proximal medial humerus. One-year postoperative bone density was not related to sex, age, cement use, or preoperative diagnosis. Higher preoperative bone density was better maintained postoperatively. Furthermore, 1 year post RSA, spot welds were observed in approximately 48.2% of cases at the distal medial portion of the stem coating, and bone resorption occurred in the proximal medial humerus in 43.2% of cases. Therefore, postoperative bone density is related to preoperative bone density, suggesting the importance of maintaining high preoperative bone density.
Collapse
Affiliation(s)
- Daisuke Soma
- Department of Orthopaedic Surgery, Kanazawa Medical University, Daigaku 1-1, Uchinada-machi, Kahoku-gun 920-0293, Ishikawa, Japan; (D.S.)
| | - Toru Ichiseki
- Department of Orthopaedic Surgery, Kanazawa Medical University, Daigaku 1-1, Uchinada-machi, Kahoku-gun 920-0293, Ishikawa, Japan; (D.S.)
| | - Shusuke Ueda
- Department of Orthopaedic Surgery, Kanazawa Medical University, Daigaku 1-1, Uchinada-machi, Kahoku-gun 920-0293, Ishikawa, Japan; (D.S.)
| | - Masaru Sakurai
- Social and Environmental Medicine, Kanazawa Medical University, Daigaku 1-1, Uchinada-machi, Kahoku-gun 920-0293, Ishikawa, Japan;
| | - Norio Kawahara
- Department of Orthopaedic Surgery, Kanazawa Medical University, Daigaku 1-1, Uchinada-machi, Kahoku-gun 920-0293, Ishikawa, Japan; (D.S.)
| |
Collapse
|
19
|
Reeves JM, Spangenberg GW, Elwell JA, Stewart B, Vanasse T, Roche C, Faber KJ, Langohr GDG. Implications of humeral short-stem diametral sizing on implant stability. JSES Int 2023; 7:2445-2453. [PMID: 37969503 PMCID: PMC10638575 DOI: 10.1016/j.jseint.2023.06.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2023] Open
Abstract
Background Shoulder arthroplasty humeral stem design has evolved to include various shapes, coatings, lengths, sizes, and fixation methods. While necessary to accommodate patient anatomy characteristics, this creates a surgical paradox of choice. The relationship between the surgeon's selection of short-stem implant size and construct stiffness, resistance to subsidence and micromotion has not been assessed. Methods Eight paired cadaveric humeri were reconstructed with surgeon-selected (SS) and 2-mm diametrically larger (SS+2) short-stemmed press-fit implants. Each reconstruction was subjected to 2000 cycles of 90° forward flexion loading, and stem subsidence and micromotion were measured using optical tracking. Compressive stiffness of the stem-bone reconstruction was then assessed by applying a load in-line with the stem axis that resulted in 5 mm of stem subsidence. Results Increasing stem size by 2 mm resulted in the construct stiffness more than doubling compared to SS stems (-741 ± 243 N/mm vs. -334 ± 120 N/mm; P = .003; power = 0.971). These larger stems also subsided significantly less than their SS counterparts (SS: 1.2 ± 0.6 mm; SS+2: 0.5 ± 0.5 mm; P = .029; power = 0.66), though there were no significant changes in micromotion (SS: 169 ± 59 μm; SS+2: 187 ± 52 μm; P = .506; power = 0.094). Conclusions The results of this study highlight the importance of proper short-stem sizing, as a relatively small 2 mm increase in diametral size was observed to significantly impact construct stiffness, which could increase the risk of stress shielding and implant loosening. Future work should focus on developing tools that objectively quantify bone quality and aid surgeons in selecting the appropriate size short-stem humeral implants for a particular patient.
Collapse
Affiliation(s)
- Jacob M. Reeves
- Department of Mechanical and Materials Engineering, The University of Western Ontario, London, ON, Canada
- The Roth | McFarlane Hand and Upper Limb Centre, London, ON, Canada
| | - Gregory W. Spangenberg
- Department of Mechanical and Materials Engineering, The University of Western Ontario, London, ON, Canada
- The Roth | McFarlane Hand and Upper Limb Centre, London, ON, Canada
| | | | | | | | | | - Kenneth J. Faber
- Department of Mechanical and Materials Engineering, The University of Western Ontario, London, ON, Canada
- The Roth | McFarlane Hand and Upper Limb Centre, London, ON, Canada
| | - G. Daniel G. Langohr
- Department of Mechanical and Materials Engineering, The University of Western Ontario, London, ON, Canada
- The Roth | McFarlane Hand and Upper Limb Centre, London, ON, Canada
| |
Collapse
|
20
|
Lukasiewicz P, McFarland E, Hassebrock JD, McCarthy TP, Sylvia SM, McCarty EC, Weber SC. Anatomic glenohumeral arthroplasty: State of the art. J ISAKOS 2023; 8:296-305. [PMID: 37207983 DOI: 10.1016/j.jisako.2023.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 04/30/2023] [Accepted: 05/11/2023] [Indexed: 05/21/2023]
Abstract
Anatomical total shoulder arthroplasty in its modern form where it reproduces the normal shoulder has been utilized clinically for more than half a century. As the technology and the designs have changed to recreate the humeral and glenoid sides of the joint, the sophistication of design has resulted in the growing number of cases annually worldwide. This increase is due in part to the increasing number of indications that the prosthesis can treat with successful results. On the humeral side, there have been design changes to better reflect the proximal humeral anatomy, and humeral stems are increasingly placed safely without cement. Platform systems which allow conversion of a failed arthroplasty to a reverse configuration without stem extraction is another design change. Similarly, there has been increasing utilization of short stem and stemless humeral components. Extensive experience with shorter stem and stemless devices, however, has yet to demonstrate the purported advantages of these devices, as recent studies have demonstrated equivalent blood loss, fracture rates, operative times, and outcome scores. Easier revision with these shorter stems remains to be definitively established, with only one study comparing the ease of revision between stem types. On the glenoid side, hybrid cementless glenoids, inlay glenoids, cementless all-polyethylene glenoids, and augmented glenoids have all been investigated; however, the indications for these devices remain unclear. Lastly, innovative surgical approaches to implanting shoulder arthroplasty and the use of patient specific guides and computerized planning, while interesting concepts, still await validation before they are utilized on a widespread basis. While reverse shoulder arthroplasty has been increasingly used to reconstruct the arthritic shoulder, anatomic glenohumeral replacement maintains a significant role in the armamentarium of the shoulder surgeon.
Collapse
Affiliation(s)
- Piotr Lukasiewicz
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA
| | - Edward McFarland
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA
| | - Jeffrey D Hassebrock
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Timothy P McCarthy
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Stephen M Sylvia
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Eric C McCarty
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Stephen C Weber
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA.
| |
Collapse
|
21
|
Tavakoli A, Spangenberg GW, Reeves JM, Faber KJ, Langohr GDG. The effect of humeral head positioning and incomplete backside contact on bone stresses following total shoulder arthroplasty with a short humeral stem. J Shoulder Elbow Surg 2023; 32:1988-1998. [PMID: 37230287 DOI: 10.1016/j.jse.2023.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 03/27/2023] [Accepted: 04/05/2023] [Indexed: 05/27/2023]
Abstract
BACKGROUND The use of uncemented humeral stems in total shoulder arthroplasty (TSA) is known to be associated with stress shielding. This may be decreased with smaller stems that are well-aligned and do not fill the intramedullary canal; however, the effect of humeral head positioning and incomplete head backside contact has not yet been investigated. The purpose of this study was to quantify the effect of changes in humeral head position and incomplete head backside contact on bone stresses and expected bone response following reconstruction. METHODS Three-dimensional finite element models of 8 cadaveric humeri were generated, which were then virtually reconstructed with a short-stem implant. An optimally sized humeral head was then positioned in both a superolateral and inferomedial position for each specimen that was in full contact with the humeral resection plane. Additionally, for the inferomedial position, 2 incomplete humeral head backside contact conditions were simulated whereby contact was defined between only the superior or inferior half of the backside of the humeral head and the resection plane. Trabecular properties were assigned based on computed tomography attenuation and cortical bone was applied uniform properties. Loads representing 45° and 75° of abduction were then applied, and the resulting differentials in bone stress versus the corresponding intact state and the expected time-zero bone response were determined and compared. RESULTS The superolateral position reduced resorbing potential in the lateral cortex and increased resorbing potential in the lateral trabecular bone, while the inferomedial position produced the same effects but in the medial quadrant. For the inferomedial position, full backside contact with the resection plane was best in terms of changes in bone stress and expected bone response, although a small region of the medial cortex did experience no load transfer. The implant-bone load transfer of the inferior contact condition was concentrated at the midline of the backside of the humeral head, leaving the medial aspect largely unloaded as a result of the lack of lateral backside support. DISCUSSION This study shows that inferomedial humeral head positioning loads the medial cortex at the cost of unloading the medial trabecular bone, with the same occurring for the superolateral position except that the lateral cortex is loaded at the cost of unloading the lateral trabecular bone. Inferomedial positioned heads also were predisposed to humeral head lift-off from the medial cortex, which may increase the risk of calcar stress shielding. For the inferomedial head position, full contact between the implant and resection plane was preferable.
Collapse
Affiliation(s)
- Amir Tavakoli
- Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| | - Gregory W Spangenberg
- Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada
| | - Jacob M Reeves
- The Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada
| | - Kenneth J Faber
- The Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada
| | - G Daniel G Langohr
- Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada.
| |
Collapse
|
22
|
Lee HH, Park SE, Ji JH, Jun HS. Mid-term comparative study between the glenoid and humerus lateralization designs for reverse total shoulder arthroplasty: which lateralization design is better? BMC Musculoskelet Disord 2023; 24:290. [PMID: 37059977 PMCID: PMC10103464 DOI: 10.1186/s12891-023-06383-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 03/30/2023] [Indexed: 04/16/2023] Open
Abstract
INTRODUCTION The complications of the conventional medialized design for reverse total shoulder arthroplasty (RSA) are increased scapular notching, and decreased external rotation and deltoid wrapping. Currently, lateralization design RSA, which avoid scapular notching and improve impingement-free range of motion, is commonly used. Especially, humeral lateralization design was most commonly used and glenoid lateralization design was preferred for glenoid abnormities. We compared mid-term clinical and radiologic outcomes of glenoid and humeral lateralization RSA in an Asian population in this study. MATERIALS AND METHODS We enrolled 124 shoulders of 122 consecutive patients (mean age 73.8 ± 6.8 years) who received glenoid or humeral lateralization RSA from May, 2012 to March, 2019. We divided these patients into two groups according to RSA using either glenoid or humeral lateralization design. These different designs were introduced consecutively in Korea. The clinical and radiological results of 60 glenoid lateralization RSA (Group I, 60 patients) and 64 humeral lateralization RSA (Group II, 62 patients) were retrospectively evaluated and also were compared between the two groups. All patients were followed for mean 3 years. RESULTS The clinical and radiologic outcomes of the two groups did not differ significantly, including scapular notching (p = 0.134). However, humeral lateralization RSA showed a larger glenoid-tuberosity (GT) distance (p = 0.000) and less distalization shoulder angle (DSA) (p = 0.035). The complication rate did not differ significantly either. But, revision surgery was performed for 2 humeral loosening in the Group II. CONCLUSION The clinical and radiologic outcomes of the two groups did not differ significantly, including scapular notching at mid-term follow-up. However, humeral lateralization design showed larger GT distance and less DSA. Humeral lateralization design RSA could preserve the normal shoulder contour due to a larger GT distance (more lateralization) and provide less deltoid tension due to less DSA (less distalization of COR).
Collapse
Affiliation(s)
- Hwan-Hee Lee
- Department of Orthopedic Surgery, The Catholic University of Korea, Seoul, Republic of Korea
| | - Sang-Eun Park
- Department of Orthopedic Surgery, The Catholic University of Korea, Seoul, Republic of Korea
| | - Jong-Hun Ji
- Department of Orthopedic Surgery, The Catholic University of Korea, Seoul, Republic of Korea.
- Department of Orthopedic Surgery, Daejeon St. Mary's Hospital, The Catholic University of Korea, 64 Daeheung-Ro, Jung-Gu, Daejeon, 34943, Korea.
| | - Hyun-Sik Jun
- Department of Orthopedic Surgery, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
23
|
Raiss P, Wittmann T, Blakeney W, Urvoy M, Walch G. Validation of the distal filling ratio in uncemented convertible short-stem shoulder arthroplasty. Arch Orthop Trauma Surg 2023; 143:1833-1839. [PMID: 35174410 DOI: 10.1007/s00402-022-04389-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 02/05/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Radiographic stress shielding is a common finding in uncemented convertible short-stem shoulder arthroplasty (UCSSSA). The distal filling ratio (DFR) has been described as a predictor for the occurrence of stress shielding. A DFR > 70% was mentioned as a risk factor for the occurrence of stress shielding for some UCSSSA. However, measurements were only performed on conventional radiographs and no validation exists for 3D automated planning tools. METHODS DFR was manually measured on postoperative true ap radiographs of 76 shoulder arthroplasties using a standardized protocol and were compared to preoperative CT scans with an automated calculation of the DFR after virtual implantation of the stem. RESULTS The mean DFR measured on X-rays was 75.9% (SD = 8.7; 95% CI = 74-78) vs. 78.9% (SD = 9.1; 95% CI = 76.8-83) automatically measured on CT scans. This difference was significant (p < 0.001). In 7 out of 76 cases (9%) the difference between manual measurement on radiographs and computerized measurement on CT scans was > 10%. CONCLUSION Manual measurement of the DFR is underestimated on conventional radiographs compared to automated calculation on CT scans be a mean of 3%. Therefore, automated measurement of the DFR on CT scans seems to be beneficial, especially in cases with osteopenic cortices. Manual measurement of the DFR on conventional ap radiographs in cases without CT scans, however, is still a viable alternative. LEVEL OF EVIDENCE Level IV, retrospective study.
Collapse
Affiliation(s)
- Patric Raiss
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, München, Germany.
| | - Thomas Wittmann
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, München, Germany
| | - William Blakeney
- Department of Orthopaedic Surgery, Royal Perth Hospital, Victoria Square, Perth, WA, 6000, Australia
| | - Manuel Urvoy
- IMASCAP, 145 Rue René Descartes, 29280, Plouzané, France
| | - Gilles Walch
- Centre Orthopedique Santy, 24, Avenue Paul Santy, 69008, Lyon, France
| |
Collapse
|
24
|
Loew M, Schnetzke M, Kappes S, Bruckner T, Nolte AK. Complications and revisions in anatomic and reverse short stem shoulder arthroplasty. Arch Orthop Trauma Surg 2023:10.1007/s00402-023-04802-4. [PMID: 36795151 PMCID: PMC9933035 DOI: 10.1007/s00402-023-04802-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 01/26/2023] [Indexed: 02/17/2023]
Abstract
INTRODUCTION One current trend in the field of shoulder arthroplasty is a design shift to shorter and metaphyseal fixed humeral stem components. The aim of this investigation is to analyze complications resulting in revision surgery after anatomic (ASA) and reverse (RSA) short stem arthroplasty. We hypothesize that complications are influenced by the type of prosthesis and indication for arthroplasty. MATERIALS AND METHODS A total of 279 short stem shoulder prostheses were implanted by the same surgeon (162 ASA; 117 RSA), and 223 of these prostheses were implanted as primary procedures; in 54 cases, arthroplasty was performed secondary to prior open surgery. Main indications were osteoarthritis (OA) (n = 134), cuff tear arthropathy (CTA) (n = 74) and posttraumatic deformities (PTr) (n = 59). Patients were evaluated at 6 weeks (follow-up 1; FU1), 2 years (FU2) and the time span of the last follow-up defined as FU3 with a minimum FU of 2 years. Complications were categorized into early complications (within FU1), intermediate complications (within FU2) and late complications (> 2 years; FU3). RESULTS In total, 268 prostheses (96.1%) were available for FU1; 267 prostheses (95.7%) were available for FU2 and 218 prostheses (77.8%) were available for FU3. The average time for FU3 was 53.0 months (range 24-95). A complication leading to revision occurred in 21 prostheses (7.8%), 6 (3.7%) in the ASA group and 15 (12.7%) in the RSA group (p < 0.005). The most frequent cause for revision was infection (n = 9; 42.9%). After primary implantation, 3 complications (2.2%) occurred in the ASA and 10 complications (11.0%) in the RSA group (p < 0.005). The complication rate was 2.2% in patients with OA, 13.5% in CTA and 11.9% in PTr. CONCLUSIONS Primary reverse shoulder arthroplasty had a significantly higher rate of complications and revisions than primary and secondary anatomic shoulder arthroplasty, respectively. Therefore, indications for reverse shoulder arthroplasty should be critically questioned in each individual case.
Collapse
Affiliation(s)
- Markus Loew
- German Joint Centre, ATOS Clinic Heidelberg, Bismarckstraße 9, 69115 Heidelberg, Germany
| | - Marc Schnetzke
- German Joint Centre, ATOS Clinic Heidelberg, Bismarckstraße 9, 69115 Heidelberg, Germany
| | - Sophia Kappes
- German Joint Centre, ATOS Clinic Heidelberg, Bismarckstraße 9, 69115 Heidelberg, Germany
| | - Thomas Bruckner
- grid.5253.10000 0001 0328 4908Institution for Medical Biometrics, Heidelberg University Hospital, INF 130.3, 69120 Heidelberg, Germany
| | - Anna-Katharina Nolte
- Department of Orthopaedics, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany.
| |
Collapse
|
25
|
Galvin JW, Kim R, Ment A, Durso J, Joslin PMN, Lemos JL, Novikov D, Curry EJ, Alley MC, Parada SA, Eichinger JK, Li X. Outcomes and complications of primary reverse shoulder arthroplasty with minimum of 2 years' follow-up: a systematic review and meta-analysis. J Shoulder Elbow Surg 2022; 31:e534-e544. [PMID: 35870805 DOI: 10.1016/j.jse.2022.06.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 05/26/2022] [Accepted: 06/05/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Primary reverse shoulder arthroplasty (rTSA) is an effective treatment option for reducing pain and improving function for patients with rotator cuff tear arthropathy, irreparable rotator cuff tears, glenoid deformity, and other challenging clinical scenarios, including fracture sequelae and revision shoulder arthroplasty. There has been a wide range of reported outcomes and postoperative complication rates reported in the literature. The purpose of this systematic review and meta-analysis is to provide an updated review of the clinical outcomes and complication rates following primary rTSA. METHODS A systematic review and meta-analysis was performed to evaluate outcomes and complications following primary rTSA according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Demographics, range of motion, patient-reported outcome measures (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form [ASES] and Constant scores), number of complications, and revisions were extracted, recorded, and analyzed from the included articles. RESULTS Of the 1415 studies screened, 52 studies met the inclusion criteria comprising a total of 5824 shoulders. The mean age at the time of surgery was 72 years (range: 34-93), and the mean follow-up was 3.9 years (range: 2-16). Patients demonstrated a mean improvement of 56° in active flexion, 50° in active abduction, and 14° in active external rotation. Regarding functional outcome scores, rTSA patients demonstrated a mean clinically significant improvement of 37 in Constant score (minimal clinically important difference [MCID] = 5.7) and ASES score (42.0; MCID = 13.6). The overall complication rate for rTSA was 9.4% and revision rate of 2.6%. Complications were further subdivided into major medical complications (0.07%), shoulder- or surgical-related complications (5.3%), and infections (1.2%). The most frequently reported shoulder- or surgical-related complications were scapular notching (14.4%), periprosthetic fracture (0.8%), glenoid loosening (0.7%), and prosthetic dislocation (0.7%). DISCUSSION Primary rTSA is a safe and reliable procedure with low complication, revision, infection, and scapular notching rates. Additionally, patients demonstrated clinically significant improvements in both range of motion and clinical outcome scores.
Collapse
Affiliation(s)
| | - Ryan Kim
- Boston University School of Medicine, Boston, MA, USA
| | - Alexander Ment
- The University of Connecticut School of Medicine, Farmington, CT, USA
| | | | | | | | - David Novikov
- Boston University School of Medicine, Boston, MA, USA
| | - Emily J Curry
- Boston University School of Medicine, Boston, MA, USA
| | | | | | | | - Xinning Li
- Boston University School of Medicine, Boston, MA, USA.
| |
Collapse
|
26
|
Wittmann T, Befrui N, Rieger T, Raiss P. Stem size prediction in shoulder arthroplasty with preoperative 3D planning. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04571-6. [PMID: 35963979 DOI: 10.1007/s00402-022-04571-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Accepted: 07/20/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Three-dimensional surgical planning software provides virtual reconstructions of the shoulder with automated joint indices for a preoperative case assessment. The aim of this single center study was to evaluate the concordance between the preoperatively selected humeral components and the final implants used in shoulder arthroplasty. METHODS 129 cases who had undergone anatomic (n = 16) or reverse shoulder arthroplasty (n = 117) using the same type of uncemented short stem implant and were included for review in this study. The type of arthroplasty, stem size, stem inclination, tray-offset and liner-thickness were noted preoperatively and compared to the final implant specifications used in surgery. RESULTS The type of arthroplasty matched the surgical plan in 99.2% of cases, as one case was converted from RSA to TSA. The concordance of planned to implanted stem size was 44.2% and the planned size was in range of one adjacent size in 87.6% of cases. Stem inclination in TSA matched the surgical plan in 50% of cases. Tray offset in RSA was predicted correctly in 65% and liner-thickness matched the surgical plan in 98.3% of cases. CONCLUSION Despite a low degree of concordance of planned to implanted stem sizes of 44.2%, the choice of stem size was found to be in range of one adjacent size in 87.6% of cases. Further investigations of other contributing factors are necessary to increase the accuracy of the preoperative selection of humeral implants. LEVEL OF EVIDENCE level IV, retrospective case study.
Collapse
Affiliation(s)
- Thomas Wittmann
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, Munich, Germany.
| | - Nima Befrui
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, Munich, Germany
| | - Tim Rieger
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, Munich, Germany
| | - Patric Raiss
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstrasse 6, 81369, Munich, Germany
| |
Collapse
|
27
|
Can we predict the humerus stem component size required to achieve rotational stability in metaphyseal stability concept? JSES Int 2022; 6:917-922. [DOI: 10.1016/j.jseint.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
28
|
Initial and 1-Year Radiographic Comparison of Reverse Total Shoulder Arthroplasty With a Short Versus Standard Length Stem. J Am Acad Orthop Surg 2022; 30:e968-e978. [PMID: 35297792 DOI: 10.5435/jaaos-d-21-01032] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Accepted: 02/10/2022] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION In an effort to preserve bone, humeral stems in reverse total shoulder arthroplasty (RTSA) have gradually decreased in length. The purpose of this study was to compare the immediate postoperative radiographic appearance of short-length with standard-length RTSA stems. METHODS Patients who underwent RTSA using a press-fit standard-length or short-length humeral implant with a consistent geometry (Univers Revers or Revers Apex) were evaluated in a multicenter retrospective review. Initial postoperative radiographs were used to assess initial alignment and filling ratios. In addition, radiographs were evaluated for early signs of stress shielding and/or loosening. Clinical outcome scores and range of motion were also evaluated. RESULTS Overall, 137 short-length stems and 139 standard-length stems were analyzed. Initial radiographs demonstrated a significantly higher percentage of stems placed in neutral alignment in the short-stem group (95.6% vs 89.2%, P = 0.045). Similar metaphyseal filling ratios were seen between groups, but a significantly higher diaphyseal filling ratio was observed in the short-stem group (57% vs 34%, P < 0.001). Less calcar osteolysis (2.2% vs 12.9%; P = 0.001) and fewer overall number of radiographic changes (tuberosity resorption, lucencies, and subsidence) (0.7% vs 5.0%; P = 0.033) were seen with short stems compared with the standard-length stems. CONCLUSION RTSA with a short-stem humeral implant demonstrates excellent radiographic outcomes, including low rates of loosening and subsidence at 1 year, with less early calcar osteolysis compared with a standard-length stem. LEVEL OF EVIDENCE III (Case-control).
Collapse
|
29
|
Linke P, Linke C, Neumann J, Werner AW. Midterm clinical outcome of uncemented short-stem reversed shoulder arthroplasty. Arch Orthop Trauma Surg 2022; 143:3025-3036. [PMID: 35804166 DOI: 10.1007/s00402-022-04510-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Accepted: 06/09/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION While the incidence of reverse total shoulder arthroplasty (rTSA) is increasing constantly, newer implants with designs other than the classic Grammont geometry are gaining importance. More anatomic inclination angles and lateralization are supposed to have a positive impact on clinical results and complication rates. Presentation of midterm results therefore is important to support these assumptions. The aim of this study was to report the midterm clinical outcome of primary rTSA with an uncemented humeral short-stem prosthesis (USSP) with a humeral inclination angle of 145° and the analysis of different variables on the outcome. METHODS This is a retrospective study of all patients with primary rTSA using an USSP and a combined humeral inclination angle of 145° (Ascend™ flex, Stryker) with a minimum clinical follow-up of 2 years. The implant combines a 132.5° inclination for the humeral stem with an additional 12.5° for the polyethylene inlay. Primary outcomes were patient-reported outcome measures: ASES score, simple shoulder test (SST) and subjective shoulder value (SSV). Secondary outcomes were complication and revision rates. We analyzed different variables: preoperatively gender, age, indication for surgery and status of rotator cuff. Also, the glenoid morphology was classified according to Walch and a proximal humerus cortical bone thickness measurement (CBT avg) of 6 mm was used as a threshold for osteoporosis. Postoperatively, we analyzed different radiologic parameters: filling ratio, distalization and lateralization angles according to Boutsiadis. RESULTS A total of 84 out of 99 (85%) patients with a mean FU of 46.7 months (range 24-80 months) could be included: 62 women and 22 men with a mean age of 74.7 years. Mean ASES score significantly increased from 47 preoperatively to 85.8 at the last follow-up (p = 0.001). The postoperative SST reached an average of 65.3 and the mean SSV was 83%. None of the variable parameters analyzed could be identified as a risk factor for a lower outcome defined as a SSV < 70. Three patients (3.6%) had a complication: one incomplete lower plexus lesion, one dislocation and one major hematoma. Surgical revision was needed in two cases (2.4%). CONCLUSION The midterm clinical outcome of primary reverse total shoulder arthroplasty (rTSA) with an uncemented humeral short stem and a humeral inclination angle of 145° showed good-to-excellent results with a low complication and revision rate independent from a wide range of pre- and postoperative variables. PROMs are comparable to those reported for anatomic TSA with a low complication rate, different to historical studies especially with the Grammont design. LEVEL OF EVIDENCE Treatment study, Level IV.
Collapse
Affiliation(s)
- Philip Linke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Carolin Linke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Jörg Neumann
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Andreas W Werner
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany. .,MVZ Argon, Department of Sports Medicine/Orthopaedics, ARGON Orthopädie, Große Bleichen 5, 20354, Hamburg, Germany.
| |
Collapse
|
30
|
A 135° Short Inlay Humeral Stem Leads to Comparable Radiographic and Clinical Outcomes Compared to a Standard-Length Stem for Reverse Shoulder Arthroplasty. JSES Int 2022; 6:802-808. [PMID: 36081694 PMCID: PMC9446177 DOI: 10.1016/j.jseint.2022.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background Humeral stem length in reverse total shoulder arthroplasty (RTSA) has decreased in recent years in an attempt to preserve more bone and facilitate stem removal in the revision setting. The purpose of this study was to compare the clinical and radiographic outcomes of a short- to standard-length stem RTSA. The authors hypothesized that there would be no difference in radiographic or clinical outcomes at short-term follow-up. Methods Patients who underwent RTSA using a press-fit standard- or short-length humeral component with a consistent geometry (Univers Revers, or Revers Apex; Arthrex, Inc., Naples, FL, USA) were evaluated in a multicenter retrospective review. The minimum clinical follow-up was 2 years. Immediate postoperative radiographs were used to assess initial alignment and filling ratios. In addition, radiographs at 2 years were evaluated for signs of stress shielding and/or loosening. Clinical outcome scores and range of motion were evaluated at the final follow-up and compared between groups. Results A total of 220 patients with short-stem RTSA and 357 patients with standard-length stem RTSA were analyzed. There was no difference in baseline function between short- and standard-length stem patients. Patients in the short stem group had higher postoperative American Shoulder and Elbow Surgeons (84.6 vs. 80.8; P = .014) and Western Ontario Osteoarthritis of the Shoulder (86.5 vs. 82.7; P = .025). Patients in the short stem group also had greater postoperative active forward flexion (139° vs. 132°; P = .003) and internal rotation with the arm at 90° of abduction (43° vs. 32°; P < .001) than patients in the standard-length group. Radiographically, there was a higher metaphyseal (P = .049) and diaphyseal (P < .001) fill ratio in the short stem group, although there was no difference in postoperative alignment, radiographic signs of loosening, or revision for loosening between groups (all P > .05). Conclusion A short inlay stem leads to comparable radiographic findings and revision-free survival compared with a standard-length stem when placed with a press-fit technique for RTSA. Clinical outcomes are also equivalent or slightly improved with a short stem compared with a standard-length stem.
Collapse
|
31
|
A Radiographic Analysis of Proximal Humeral Anatomy in Patients with Primary Glenohumeral Arthritis and Implications for Press-Fit Stem Length. J Clin Med 2022; 11:jcm11102867. [PMID: 35628993 PMCID: PMC9148163 DOI: 10.3390/jcm11102867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/01/2022] [Accepted: 05/17/2022] [Indexed: 11/17/2022] Open
Abstract
While short stems in total shoulder arthroplasty (TSA) preserve bone stock and facilitate revision surgery, they have been associated with higher rates of malalignment and loosening in some cases compared to standard length stems. The purpose of this study was to analyze the intramedullary canal in progressive increments distal to the greater tuberosity to provide anatomic information about the optimal length of press-fit short stems for alignment and stability in TSA. We hypothesized that the humeral canal diameter will remain variable for the first 50 to 75 mm distal to the greater tuberosity and will become consistent thereafter. A retrospective review of 99 consecutive patients undergoing TSA with CT scans was performed. Intramedullary anterior-posterior (AP) and medial-lateral (ML) width as well as diameter were analyzed on two-dimensional computed tomography following multiplanar reconstruction. Measurements were taken at consistent distances distal to the greater tuberosity (GT). The transition point was measured at the proximal level of the humerus where endosteal borders of the medial and lateral cortices became parallel. The mean transition point was 73 mm from the GT (range: 53 to 109 mm). ML and AP widths became consistent 80 mm distal to the GT. IM diameter became consistent after 90 mm distal to the GT and a stem length of 90 mm extended past the transition point in 91.9% of cases. In TSA, a humeral stem length of 90 mm is required to predictably reach points at which the humeral canal becomes cylindrical and consistent in diameter. This information may aid data-driven decisions on humeral stem length during press-fit fixation, assuring consistency of alignment and implant stability, while maintaining ease of revision associated with a short stem implant. Level of evidence: III
Collapse
|
32
|
Gunst S, Nigues A, Vogels J, Servien E, Lustig S, Nove-Josserand L, Collotte P. Using standard-length compactors to implant short humeral stems in total shoulder arthroplasty: A cadaver study of humeral stem alignment. PLoS One 2022; 17:e0268075. [PMID: 35511898 PMCID: PMC9070928 DOI: 10.1371/journal.pone.0268075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 04/21/2022] [Indexed: 11/21/2022] Open
Abstract
Background Short-stem implants in shoulder arthroplasty were recently developed and reported clinical outcomes are good. However, radiological analysis often reveals humeral stem misalignment in the frontal plane, along with high filling ratios that can lead to proximal bone remodeling under stress shielding. The aim of this cadaveric study was to test whether using compactors for standard-length (> 100 mm) stems to implant short (< 100 mm) stems reduces the risk of stem misalignment without compromising in terms of a higher filling ratio. Methods In a cadaveric study, twenty short stems were implanted using instrumentation for standard-length stems. Alignment and filling ratios were evaluated on anteroposterior radiographs for both the compactors and the stems. The angular deviations (α) from the humeral axis of the compactors and the short stems were measured. Misalignment was defined as |α| > 5°. Metaphyseal and diaphyseal filling ratios were calculated and defined as either high (≥ 0.7) or low (< 0.7). Results The median angular deviations of the compactors and the short stems were respectively 1.6° (range, 0.03 to 5.9°) and 1.3° (range, 0.3 to 9.6°). Nineteen of the 20 compactors (95%) and 17/20 short stems (85%) were correctly aligned. The proportions of correctly aligned compactors and stems were not significantly different (95% CI, −0.33 to 0.11; Z-test of proportions p = .60), and the respective angular deviations were significantly correlated (Spearman ρ = .60, p = 0.006). The diaphyseal and metaphyseal filling ratios of the compactors and the stems were all low. Conclusions In this series of 20 implants in cadavers, the narrow short humeral stems implanted with compactors for standard-length stems were correctly aligned with the humeral axis. This approach may be a way to achieve both correct frontal alignment and low filling ratios.
Collapse
Affiliation(s)
- Stanislas Gunst
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, Lyon, France
- * E-mail:
| | - Ana Nigues
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Jérôme Vogels
- Hand and Upper Extremity Surgical Institute, Clinique du Medipole, Villeurbanne, France
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
- LIBM–EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| | - Sébastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, Lyon, France
| | - Laurent Nove-Josserand
- Ramsay Générale de Santé, Jean Mermoz Private Hospital, Centre Orthopédique Santy, Lyon, France
| | - Philippe Collotte
- Ramsay Générale de Santé, Jean Mermoz Private Hospital, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
33
|
Roberts CC, Metter DF, Fox MG, Appel M, Jawetz ST, Morrison WB, Nacey N, Said N, Stensby JD, Subhas N, Tynus KM, Walker EA, Yu JS, Kransdorf MJ. ACR Appropriateness Criteria® Imaging After Shoulder Arthroplasty: 2021 Update. J Am Coll Radiol 2022; 19:S53-S66. [PMID: 35550805 DOI: 10.1016/j.jacr.2022.02.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 02/19/2022] [Indexed: 11/19/2022]
Abstract
Shoulder arthroplasty is a common orthopedic procedure with a complication rate reported to be as high as 39.8% and revision rates as high as 11%. Symptoms related to postoperative difficulties include activity-related pain, decreased range of motion, and apprehension. Some patients report immediate and persistent dissatisfaction, although others report a symptom-free postoperative period followed by increasing pain and decreasing shoulder function and mobility. Imaging plays an important role in diagnosing postoperative complications of shoulder arthroplasties. The imaging algorithm should always begin with radiographs. The selection of the next imaging modality depends on several factors, including findings on the initial imaging study, clinical suspicion of an osseous versus soft-tissue injury, and clinical suspicion of infection.The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
Affiliation(s)
| | | | - Michael G Fox
- Panel Chair, Musculoskeletal Division Chair and Diagnostic Radiology Program Director, Mayo Clinic Arizona, Phoenix, Arizona
| | - Marc Appel
- James J. Peters VA Medical Center, Bronx, New York; American Academy of Orthopaedic Surgeons; and liaison with AOOS
| | - Shari T Jawetz
- Director, Radiology Quality Assurance; Director, Radiology Resident and Medical Student Education; and Chief, Division of Body CT, Hospital for Special Surgery, New York, New York
| | - William B Morrison
- Director, Division of Musculoskeletal Radiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania; ACR education center faculty; ACR AIRP faculty; ACR CPI author
| | - Nicholas Nacey
- Fellowship Director, Imaging Center Medical Director, University of Virginia Health System, Charlottesville, Virginia
| | - Nicholas Said
- Medical Director of MRI Duke University Health System, Access Champion Department of Radiology, Director of Musculoskeletal Intervention, Duke University Medical Center, Durham, North Carolina
| | - James D Stensby
- MSK Imaging Fellowship Director, University of Missouri Health Care, Columbia, Missouri
| | - Naveen Subhas
- Vice Chair of Clinical Effectiveness and Efficiency, Imaging Institute Program Director, Musculoskeletal Radiology; and Director, Bone Mineral Densitometry, Cleveland Clinic, Cleveland, Ohio
| | - Katherine M Tynus
- Northwestern Memorial Hospital, Chicago, Illinois; American College of Physicians
| | - Eric A Walker
- Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania and Uniformed Services University of the Health Sciences, Bethesda, Maryland; Past President of the Penn State College of Medicine Faculty Organization, ACR local chapter PRS President Elect
| | - Joseph S Yu
- The Ohio State University Wexner Medical Center, Columbus, Ohio
| | | |
Collapse
|
34
|
Erickson BJ, Werner BC, Griffin JW, Gobezie R, Lederman E, Sears BW, Bents E, Denard PJ. A comprehensive evaluation of the association of radiographic measures of lateralization on clinical outcomes following reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2022; 31:963-970. [PMID: 34715281 DOI: 10.1016/j.jse.2021.10.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 09/29/2021] [Accepted: 10/06/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although reverse total shoulder arthroplasty (RTSA) has excellent reported outcomes and satisfaction, patients often have postoperative limitations in range of motion (ROM), specifically internal rotation. Increased lateralization is thought to improve ROM following RTSA. The purpose of this study was to evaluate the association between radiographic measurements of lateralization and postoperative ROM and clinical outcome scores following RTSA. The authors hypothesized that increased radiographic lateralization would be associated with improved postoperative ROM, specifically internal rotation, but have no significant association with clinical outcome scores. METHODS Patients who underwent RTSA with a 135° neck-shaft angle prosthesis and minimum 2-year clinical and radiographic follow-up were included and retrospectively reviewed. Postoperative radiographs were evaluated for several lateralization measurements including the lateralization shoulder angle (LSA), distance from the lateral border of the acromion to the lateral portion of the glenosphere, distance from the glenoid to the most lateral aspect of the greater tuberosity, and the distance from the lateral aspect of the acromion to the most lateral aspect of the greater tuberosity. Linear regression analyses were used to evaluate the independent association of each radiographic measurement of lateralization on forward flexion, external rotation, internal rotation, and the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) index score at 2 years postoperation. Receiver operating characteristic (ROC) curves were constructed to identify significant thresholds of each radiographic lateralization measurement. RESULTS A total of 203 patients were included. For internal rotation, a greater LSA (P = .007), shorter acromion to glenosphere distance (meaning more glenoid lateralization) (P = .005), and a greater acromion to greater tuberosity distance (with the tuberosity more lateral to the acromion) (P = .021) were associated with improved internal rotation. Overall, ROC analysis demonstrated very little significant data, the most notable of which was the LSA, which had a significant cutoff of 82° (sensitivity 57%, specificity 68%, P = .012). CONCLUSION Of the numerous radiographic measures of lateralization after RTSA, the LSA is the most significantly associated with outcomes, including improved internal rotation and a decrease in forward flexion and ASES score. The clinical significance of these statistically significant findings requires further study, as the observed associations were for very small changes that may not represent clinical significance.
Collapse
Affiliation(s)
| | | | | | | | - Evan Lederman
- University of Arizona College of Medicine-Phoenix, Phoenix, AZ Banner Health, Phoenix, AZ, USA
| | | | | | | |
Collapse
|
35
|
Bülhoff M, Zeifang F, Welters C, Renkawitz T, Schiltenwolf M, Tross AK. Medium- to Long-Term Outcomes after Reverse Total Shoulder Arthroplasty with a Standard Long Stem. J Clin Med 2022; 11:2274. [PMID: 35566400 PMCID: PMC9103013 DOI: 10.3390/jcm11092274] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/02/2022] [Accepted: 04/13/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Long-term clinical and radiographic outcome data after standard cemented long-stem reverse shoulder arthroplasty (RSA) remain underreported. The aim of this study is to report on medium- to long-term data of patients over 60 years of age. Methods: The same type of RSA (Aequalis Reverse II, Memphis, TN, USA) was implanted in 27 patients with a mean age of 73 years (range 61−84). Indications for RSA were cuff tear arthropathy (CTA) in 25 cases and osteoarthritis (OA) in two cases. Pre- and postoperative Constant Score was assessed and component loosening, polyethylene wear, scapular notching and revision rates were recorded at a mean clinical follow-up (FU) of 127.6 months (SD ± 33.7; range 83−185). Results: The mean-adjusted CS (aCS) improved from 30.0 (range 10−59) to 95.0 (range 33−141) points (p < 0.001). Glenoid loosening was found in two (9.1%) and stem loosening was found in three (13.6%) cases. Polyethylene wear was observed in four (18.2%) cases. Scapular notching appeared in 15 (68.2%) cases but was not associated with poor aCS (p = 0.423), high levels of pain (p = 0.798) or external rotation (p = 0.229). Revision surgery was necessary in three (11.1%) cases. Conclusions: RSA with a cemented standard long stem leads to improvement in forward elevation, abduction and pain after a mean FU of 10 years. However, external rotation does not improve with this prosthetic design. Moreover, scapular notching is observed in the majority of cases, and revision rates (11.1%) as well as humeral loosening rates (13.6%) remain a concern. Level of evidence: Level 4, retrospective cohort study.
Collapse
Affiliation(s)
- Matthias Bülhoff
- Clinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.B.); (T.R.); (M.S.)
| | - Felix Zeifang
- Ethianum Clinic Heidelberg, Voßstraße 6, 69115 Heidelberg, Germany;
| | - Caroline Welters
- Clinic for Dermatology, Munich Municipal Hospital Group, Thalkirchnerstrasse 48, 80337 Munich, Germany;
| | - Tobias Renkawitz
- Clinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.B.); (T.R.); (M.S.)
| | - Marcus Schiltenwolf
- Clinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.B.); (T.R.); (M.S.)
| | - Anna-K. Tross
- Clinic for Orthopaedic Surgery, Heidelberg University Hospital, Schlierbacher Landstraße 200a, 69118 Heidelberg, Germany; (M.B.); (T.R.); (M.S.)
| |
Collapse
|
36
|
Kim SC, Park JH, Bukhary H, Yoo JC. Humeral stem with low filling ratio reduces stress shielding in primary reverse shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2022; 46:1341-1349. [PMID: 35353240 DOI: 10.1007/s00264-022-05383-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 03/18/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Some patients show severe humeral bone stress shielding even one year after press-fit humeral stem, which can be a risk factor for implant durability. This study compared humeral stress shielding and clinical outcomes between high and low filling ratio (HFR and LFR) stems in primary reverse shoulder arthroplasty (RSA). METHODS From 2015 to 2020, 104 patients who underwent RSA with a non-cemented standard-length humeral stem were examined. The humeral stems included large press-fit stems (HFR group, 53 patients) or small non-press-fit stems with autogenous cancellous bone grafting (LFR group, 51 patients). The radiologic and clinical outcomes were compared between the groups one year post-operatively. RESULTS One patient in the LFR group with early infectious dislocation was excluded from the 1-one year evaluation. No stress shielding was observed in 27/50 (54.0%) and 5/53 (9.4%) of patients in the LFR and HFR groups, while 3/50 (6%) and 19/53 (35.8%) patients showed high-stress shielding, respectively. However, the stem alignment change, subsidence, complications and evidence of loosening did not differ between the groups. The final range-of-motion and functional scores were significantly poorer in the LFR group than those in the HFR group, although the difference was minimal. CONCLUSION Even at one year follow-up, patients receiving LFR stems with autogenous bone grafting had significantly less humeral stress shielding compared to patients with HFR stem with press-fit in primary RSA, without compromising stem stability.
Collapse
Affiliation(s)
- Su Cheol Kim
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
| | - Jong Hun Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
| | - Hashem Bukhary
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
| | - Jae Chul Yoo
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea.
| |
Collapse
|
37
|
Reverse shoulder arthroplasty for proximal humeral fracture in the elderly. Cemented or uncemented stem? INTERNATIONAL ORTHOPAEDICS 2022; 46:635-644. [PMID: 35034145 DOI: 10.1007/s00264-021-05284-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 12/04/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The purposes of this study were to compare functional outcomes, radiographic stem changes and complication rate in patients with proximal humeral fractures operated with cemented or uncemented RSA. METHODS Retrospective review of 68 primary RSAs in PHF, 45 cemented/23 uncemented. Functional outcomes were evaluated according to constant, ASES scales and the range of motion (ROM). Radiographic assessment was performed at a minimum of two years post-operatively. RESULTS The mean follow-up cemented/uncemented was 37.8/26.5 months (p = .04) and the mean age 78/80 years old (p = .09). The functional outcome and range of movement were equivalent in the two groups except for the forward flexion that was significantly higher in the cemented group (p = .03). Stress shielding was seen in 30.4% of uncemented group and none in the cemented. Anatomic tuberosity healing was significantly higher with uncemented components compared with cemented components (64% vs 91%, p = .02). Cemented stems had radiolucent lines with a width of 2 mm or more in three or more Gruen zones in 9% vs 0% in the uncemented group and an evident change in the stem position was present in 4% vs 0% in the non-cemented group. CONCLUSION At mid-term follow-up, no differences in functional outcomes were detected depending on the stem fixation technique. Cemented stems, however, have a complication rate (including stem loosening) significantly higher than press-fit stems.
Collapse
|
38
|
Nourissat G, Corsia S, Harris HW, Bouché PA. Specific Design of a Press Fit Humeral Stem Provides low Stress Shielding in Reverse Shoulder Arthroplasty at minimum 5 Years FU. J Shoulder Elb Arthroplast 2022; 6:24715492221112543. [PMID: 35832511 PMCID: PMC9272197 DOI: 10.1177/24715492221112543] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/10/2022] [Accepted: 06/02/2022] [Indexed: 11/23/2022] Open
Abstract
Press fit fixation is becoming more popular in RSA to preserve, in theory, bone capital. Several studies report that bone resorption can be very high around humeral stems depending on their size, shape and mode of fixation. The aim of the current study is to mid-term follow-up clinical and radiological result of a press fit ovoid regular stem RSA in non acute trauma cases.
Collapse
Affiliation(s)
- Geoffroy Nourissat
- Clinique de l’épaule, COS Ramsay Santé, Clinique des Maussins & Clinique Saint Jean de Dieu, Paris, France
| | - Simon Corsia
- Service de Chirurgie Orthopédique Hôpital Cochin, APHP, Paris, France
| | | | - Pierre-Alban Bouché
- Service de Chirurgie Orthopédique Hôpital Lariboisière Saint Louis, Paris, France
| |
Collapse
|
39
|
Ascione F, Panni AS, Braile A, Corona K, Toro G, Capuano N, Romano AM. Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties, a systematic review: part II-problems and reinterventions. J Orthop Traumatol 2021; 22:49. [PMID: 34826010 PMCID: PMC8626544 DOI: 10.1186/s10195-021-00613-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 11/17/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related. METHODS This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (1 January 2000 to 14 April 2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar, employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," and "revision." RESULTS Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with overall reoperation and revision rates of 1.7% and 2.6%, respectively. CONCLUSIONS Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas no humeral fractures or stem loosening were reported with short stems. Infections (1.3%) were the most common reason for component revision, followed by instability (0.8%). LEVEL OF EVIDENCE Systematic review IV.
Collapse
Affiliation(s)
- Francesco Ascione
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via Petrarca 35, 80123, Napoli (NA), Italy. .,Orthopedics and Sport Medicine Unit, Campolongo Hospital, Salerno, Italy.
| | - Alfredo Schiavone Panni
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Adriano Braile
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Katia Corona
- Department of Medicine and Health Sciences, Università del Molise, Campobasso, Italy
| | - Giuseppe Toro
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Nicola Capuano
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via Petrarca 35, 80123, Napoli (NA), Italy
| | - Alfonso M Romano
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via Petrarca 35, 80123, Napoli (NA), Italy.,Orthopedics and Sport Medicine Unit, Campolongo Hospital, Salerno, Italy
| |
Collapse
|
40
|
Blakeney WG, Urvoy M, Chaoui J, Raiss P, Athwal GS, Walch G. Development and assessment of 3-dimensional computed tomography measures of proximal humeral bone density: a comparison to established 2-dimensional measures and intraoperative findings in patients undergoing shoulder arthroplasty. JSES Int 2021; 5:1008-1013. [PMID: 34766077 PMCID: PMC8569005 DOI: 10.1016/j.jseint.2021.07.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background The purpose of this study was to develop novel three-dimensional (3D) measures of bone density from computed tomography (CT) scans and to compare them with validated two-dimensional (2D) radiographic assessments of bone density. Patient demographic data were also analyzed to see if there were any predictors of bone density (age, sex, etiology). Methods The study group consisted of 290 consecutive patients undergoing primary shoulder arthroplasty surgery (total anatomic, reverse, and hemiarthroplasty). All underwent preoperative CT imaging. Three 3D CT measurements (metaphysis cancellous, metaphysis cortical, and proximal diaphysis) were developed and automated into software. The developed 3D measurements were compared with validated 2D measures (Tingart and Gianotti Index). Patient demographic data were correlated with these measurements. The difference between the size of the final sounder and of the final stem was calculated as Delta. Results There was moderately strong correlation between Tingart and Gianotti measures (0.674, P < .001), as well as between 3D metaphysis cancellous measurements and Tingart (0.645, P < .001). Decreased bone density was highly correlated with female sex. Tingart (area under the curve [AUC]: 0.87, 95% confidence interval [CI]: 0.82-0.91) and 3D metaphysis cancellous (AUC: 0.78, 95% CI: 0.72-0.84) had the highest correlation. These were significantly more than other measures of bone density (P < .01). Decreased bone density measured with Tingart also had moderate correlation with advanced age (AUC: 0.67, 95% CI: 0.6-0.73), but less so for etiology (AUC: 0.62, 95% CI: 0.55-0.69). The 3D metaphysis cancellous measure had lower correlation with age (AUC: 0.59, 95% CI: 0.52-0.66) and etiology (AUC: 0.59, 95% CI: 0.52-0.65). The highest correlation with Delta (the difference between the final sounder and the stem size) was with the 3D metaphysis cancellous measure (AUC: 0.67, 95% CI: 0.59-0.73), followed by Tingart (AUC: 0.647, 95% CI: 0.57-0.671). A multiple regression model to predict Delta demonstrated the stronger prediction using 3D metaphysis cancellous (analysis of variance F-ratio of 42.6, P < .001) than Tingart (35.9, P < .001). Conclusion This study demonstrates that automated measures of bone density can be obtained from 3D CT scans. Of the three novel 3D measurements of bone density, the humeral metaphysis cancellous measurement was most correlated to the known 2D measures and most correlated to the intraoperative assessment of bone density (delta).
Collapse
Affiliation(s)
| | | | | | - Patric Raiss
- Klinik für Orthopädie und Unfallchirurgie, Universität Heidelberg, Heidelberg, Germany
| | - George S Athwal
- St Joseph's Health Centre, University of Western Ontario, London, ON, Canada
| | | |
Collapse
|
41
|
Sanchez-Sotelo J. Current Concepts in Humeral Component Design for Anatomic and Reverse Shoulder Arthroplasty. J Clin Med 2021; 10:jcm10215151. [PMID: 34768670 PMCID: PMC8584456 DOI: 10.3390/jcm10215151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 10/17/2021] [Accepted: 10/18/2021] [Indexed: 11/16/2022] Open
Abstract
The history of humeral component design has evolved from prostheses with relatively long stems and limited anatomic head options to a contemporary platform with short stems and stemless implants with shared instrumentation and the ability to provide optimal shoulder reconstruction for both anatomic and reverse configurations. Contemporary humeral components aim to preserve the bone, but they are potentially subject to malalignment. Modern components are expected to favorably load the humerus and minimize adverse bone reactions. Although there will likely continue to be further refinements in humeral component design, the next frontiers in primary shoulder arthroplasty will revolve around designing an optimal plan, including adequate soft tissue tension and providing computer-assisted tools for the accurate execution of the preoperative plan in the operating room.
Collapse
|
42
|
Nabergoj M, Denard PJ, Collin P, Trebše R, Lädermann A. Radiological changes, infections and neurological complications after reverse shoulder arthroplasty related to different design types and their rates: Part II. EFORT Open Rev 2021; 6:1109-1121. [PMID: 34909229 PMCID: PMC8631237 DOI: 10.1302/2058-5241.6.210040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
Early reported complication rates with the Grammont-type reverse shoulder arthroplasty (RSA) were very high, up to 24%.A 'problem' is defined as an intraoperative or postoperative event that is not likely to affect the patient's final outcome, such as intraoperative cement extravasation and radiographic changes. A 'complication' is defined as an intraoperative or postoperative event that is likely to affect the patient's final outcome, including infection, neurologic injury and intrathoracic central glenoid screw placement.Radiographic changes around the glenoid or humeral components of the RSA are very frequently observed and described in the literature.High complication rates related to the Grammont RSA design led to development of non-Grammont designs which led to a dramatic fall in the majority of complications.The percentage of radiological changes after RSA is not negligible and remains unsolved, despite a decrease in its occurrence in the last decade. However, such changes should be now considered as simple problems because they rarely have a negative influence on the patient's final outcome, and their prevalence has dramatically decreased.With further changes in indications and designs for RSA, it is crucial to accurately track the rates and types of complications to justify its new designs and increased indications. Cite this article: EFORT Open Rev 2021;6:1109-1121. DOI: 10.1302/2058-5241.6.210040.
Collapse
Affiliation(s)
- Marko Nabergoj
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | | | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint- Grégoire, France
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
43
|
Goetti P, Denard PJ, Collin P, Ibrahim M, Mazzolari A, Lädermann A. Biomechanics of anatomic and reverse shoulder arthroplasty. EFORT Open Rev 2021; 6:918-931. [PMID: 34760291 PMCID: PMC8559568 DOI: 10.1302/2058-5241.6.210014] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The biomechanics of the shoulder relies on careful balancing between stability and mobility. A thorough understanding of normal and degenerative shoulder anatomy is necessary, as the goal of anatomic total shoulder arthroplasty is to reproduce premorbid shoulder kinematics.With reported joint reaction forces up to 2.4 times bodyweight, failure to restore anatomy and therefore provide a stable fulcrum will result in early implant failure secondary to glenoid loosening.The high variability of proximal humeral anatomy can be addressed with modular stems or stemless humeral components. The development of three-dimensional planning has led to a better understanding of the complex nature of glenoid bone deformity in eccentric osteoarthritis.The treatment of cuff tear arthropathy patients was revolutionized by the arrival of Grammont's reverse shoulder arthroplasty. The initial design medialized the centre of rotation and distalized the humerus, allowing up to a 42% increase in the deltoid moment arm.More modern reverse designs have maintained the element of restored stability but sought a more anatomic postoperative position to minimize complications and maximize rotational range of motion. Cite this article: EFORT Open Rev 2021;6:918-931. DOI: 10.1302/2058-5241.6.210014.
Collapse
Affiliation(s)
- Patrick Goetti
- Division of Orthopaedics and Trauma Surgery, Centre Hospitalier |Universitaire Vaudois, Lausanne, Switzerland
| | - Patrick J. Denard
- Denard Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, Oregon, United States
| | - Philippe Collin
- Collin Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint- Grégoire, France
| | - Mohamed Ibrahim
- Mohamed Ibrahim, Department of Orthopaedics and Trauma Surgery, Faculty of Medicine, Fayoum University, Fayoum, Egypt
| | - Adrien Mazzolari
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
44
|
Synnott S, Langohr GDG, Reeves JM, Johnson JA, Athwal GS. The effect of humeral implant thickness and canal fill on interface contact and bone stresses in the proximal humerus. JSES Int 2021; 5:881-888. [PMID: 34505100 PMCID: PMC8411059 DOI: 10.1016/j.jseint.2021.05.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background Stem size is an important element for successful time zero primary fixation of a press-fit humeral stem in shoulder arthroplasty. Little basic science research, however, has been conducted on the effects of implant thickness and canal fill on load transfer, contact, and stress shielding. The purpose of this finite element study was to determine the effects of varying stem thickness on bone contact, bone stresses, and bone resorption owing to stress shielding. Methods Three generic short-stem implant models were developed and varied based on cross-sectional thickness (thinner - 8 mm, medium - 12 mm, thicker - 16 mm). Using a finite element model, three outcome measures were determined (1) the amount of bone-to-implant contact, (2) changes in cortical and trabecular bone stresses from the intact state, and (3) changes in cortical and trabecular strain energy densities which can predict bone remodeling or stress shielding. Results Increasing the size of the humeral stem had no significant effects on bone-to-implant contact during loading (P > .07). The thinner implant with the lowest canal fill ratio produced significantly lower changes in stress from the intact state in both cortical and trabecular bone (P < .002). In addition, the thinner implant resulted in a substantially lower volume of bone predicted to stress shield and resorb when compared with the medium and thicker stems. Discussion The results demonstrate that thinner implants and lower canal fill may be beneficial over thicker sizes, provided equal initial fixation can be achieved. The thinner implant has a greater degree of load sharing and increases the mechanical load placed on surrounding bone, reducing the risk of stress shielding and bone resorption.
Collapse
Affiliation(s)
- Stephanie Synnott
- Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - G Daniel G Langohr
- Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - Jacob M Reeves
- Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - James A Johnson
- Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| | - George S Athwal
- Roth
- McFarlane Hand and Upper Limb Center Biomechanics Laboratory, London, ON, Canada
| |
Collapse
|
45
|
Märtens N, Heinze M, Awiszus F, Bertrand J, Lohmann CH, Berth A. Long-term survival and failure analysis of anatomical stemmed and stemless shoulder arthroplasties. Bone Joint J 2021; 103-B:1292-1300. [PMID: 34192923 DOI: 10.1302/0301-620x.103b7.bjj-2020-0915.r3] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
AIMS The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. METHODS A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. RESULTS The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. CONCLUSION The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292-1300.
Collapse
Affiliation(s)
- Nicole Märtens
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Maximilian Heinze
- Department of Orthopaedic Surgery, Asklepios Harzkliniken Fritz-König-Stift Bad Harzburg, Bad Harzburg, Germany
| | - Friedemann Awiszus
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Jessica Bertrand
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| | - Alexander Berth
- Department of Orthopaedic Surgery, Otto von Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
46
|
Ascione F, Schiavone Panni A, Braile A, Corona K, Toro G, Capuano N, Romano AM. Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications). J Orthop Traumatol 2021; 22:27. [PMID: 34236540 PMCID: PMC8266956 DOI: 10.1186/s10195-021-00592-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 06/28/2021] [Indexed: 01/18/2023] Open
Abstract
Background Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related. Methods This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (01.01.2000–14.04.2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar employing several combinations of keywords: “reverse shoulder arthroplasty,” “reverse shoulder prosthesis,” “inverse shoulder arthroplasty,” “inverse shoulder prosthesis,” “problems,” “complications,” “results,” “outcomes,” “reoperation,” “revision.” Results Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with an overall reoperation rate of 1.7% and overall revision rate of 2.6%. Conclusions Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem in RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas short stems reported no humeral fractures or stem loosening. Infections (1.3%) proved to be the most common reason for component revision, and instability had a complication rate of 0.8%. Level of evidence Systematic review IV
Collapse
Affiliation(s)
- Francesco Ascione
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via A. Manzoni 220, 80123, Napoli, NA, Italy. .,Orthopedics and Sport Medicine Unit, Campolongo Hospital, Salerno, Italy.
| | - Alfredo Schiavone Panni
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Adriano Braile
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Katia Corona
- Department of Medicine and Health Sciences, Università del Molise, Campobasso, Italy
| | - Giuseppe Toro
- Dipartimento Multidisciplinare Di Specialità Medico-Chirurgiche Ed Odontoiatriche, Università Degli Studi Della Campania "Luigi Vanvitelli", Napoli, Italy
| | - Nicola Capuano
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via A. Manzoni 220, 80123, Napoli, NA, Italy
| | - Alfonso M Romano
- Department of Orthopaedic and Trauma Surgery, Ospedale Buon Consiglio Fatebenefratelli, Via A. Manzoni 220, 80123, Napoli, NA, Italy.,Orthopedics and Sport Medicine Unit, Campolongo Hospital, Salerno, Italy
| |
Collapse
|
47
|
Lopiz Y, Galán-Olleros M, Rodriguez-Rodriguez L, García-Fernández C, Marco F. Radiographic changes around the glenoid component in primary reverse shoulder arthroplasty at mid-term follow-up. J Shoulder Elbow Surg 2021; 30:e378-e391. [PMID: 33197588 DOI: 10.1016/j.jse.2020.10.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 09/20/2020] [Accepted: 10/07/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Some local events after reverse shoulder arthroplasty (RSA) occur without the patient experiencing symptoms and yet may be detected on diagnostic imaging, thereby serving as indicators of future complications that may require revision. Most of these events involve the glenoid component, but radiographic studies evaluating this component are scarce, especially medium- and long-term studies. This study aimed to analyze the radiographic changes around the glenoid component and determine the risk factors associated with the presence of these radiographic changes. MATERIALS AND METHODS A retrospective review of 105 primary Grammont-style RSAs implanted between 2003 and 2014 was conducted. Radiographic outcomes were evaluated in patients with ≥5 years of radiographic follow-up. Standardized digital radiographs obtained immediately postoperatively and at a minimum follow-up time of 5 years were analyzed to determine (1) glenoid component position (inclination and height) and (2) minor radiographic changes (Sirveaux grade 1 or 2 scapular notching; nondisplaced acromial fracture; radiolucent lines around 1 or 2 screws; Brooker grade 1a, 1b, or 2 heterotopic calcifications; or single screw rupture), as well as major radiographic changes (Sirveaux grade 3 or 4 scapular notching; radiolucent lines around ≥3 screws or central peg; Brooker grade 1c or 3 heterotopic calcifications; prosthetic dislocation; loosening or migration; or disassembly). RESULTS Major radiologic changes were identified in 14.3% of the cases. Bivariate analysis showed that more changes were associated with the arthroplasties implanted in the first years of the study (odds ratio [OR] = 0.81, P = .012). This time-related variable was also associated with inclination (OR = 0.88, P = .045) and height (OR = 0.75, P = .001), improving in arthroplasties implanted in the last years of the study. Multivariate analysis revealed an increased risk of severe scapular notching mainly associated with superior tilt (OR = 2.52, P = .036) and a high (OR = 2.68, P = .019) or excessively high (OR = 7.55, P = .013) position and an increased risk of loosening signs associated with superior tilt (OR = 8.92, P = 9.1 × 10-6). CONCLUSIONS The percentage of radiologic changes of the glenoid component in RSA is considerable, despite the detection of a decrease in their presence among the arthroplasties implanted outside the initial period. Superior tilt and an excessively high position appear to be associated with a severe degree of scapular notching development and increased risk of radiographic loosening signs. Knowledge of the factors associated with major radiologic changes in the medium-term follow-up will help to optimize the primary surgical technique for each patient and indication, improving implant survival in primary RSA surgery.
Collapse
Affiliation(s)
- Yaiza Lopiz
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain; Department of Surgery, Complutense University, Madrid, Spain.
| | - María Galán-Olleros
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain
| | - Luis Rodriguez-Rodriguez
- Instituto de Investigación Sanitaria del Hospital Clínico San Carlos, UGC de Reumatología, Hospital Clínico San Carlos, Madrid, Spain
| | - Carlos García-Fernández
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain
| | - Fernando Marco
- Shoulder and Elbow Unit, Department of Traumatology and Orthopaedic Surgery, Clínico San Carlos Hospital, Madrid, Spain; Department of Surgery, Complutense University, Madrid, Spain
| |
Collapse
|
48
|
Mazaleyrat M, Favard L, Boileau P, Berhouet J. Humeral osteolysis after reverse shoulder arthroplasty using cemented or cementless stems comparative retrospective study with a mean follow-up of 9 years. Orthop Traumatol Surg Res 2021; 107:102916. [PMID: 33812096 DOI: 10.1016/j.otsr.2021.102916] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 09/19/2020] [Accepted: 10/13/2020] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The cause of proximal humeral osteolysis after reverse shoulder arthroplasty (RSA) remains controversial. The primary objective of our study was to compare the radiographic outcomes of Grammont-type RSA when a cemented stem is used versus when a cementless stem is used. The secondary objective was to identify the cause of these radiographic changes, especially for the cementless stems. HYPOTHESIS More proximal humerus bone loss occurs when a cementless humeral stem is used. METHODS With a minimum follow-up of 5 years, two paired cohorts were compared retrospectively: 70 RSA with cemented stem and 70 RSA with cementless stem. Using the radiographs made at the final follow-up visit, we looked for tuberosity resorption, signs of stress shielding, the presence of periprosthetic radiolucent lines and scapular notching. RESULTS At a mean follow-up of 9 years (5.0-20.6), the RSA revision rate was 1.8% in the cemented group and 3.6% in the cementless group (p=1). Tuberosity resorption was twice as common in the cementless group: 59% versus 30% (p<0.001). Signs of stress shielding such as osteopenia were only present in the cementless group. In both groups, tuberosity resorption was often associated with scapular notching. In the shoulders with tuberosity resorption, stage≥3 scapular notching was more common in the cementless group (p=0.001). DISCUSSION For the cementless stems, proximal humeral osteolysis can in part be attributed to stress shielding. The relationship between notching and tuberosity resorption in the two groups also suggests a secondary biological cause. LEVEL OF EVIDENCE III; Comparative retrospective study.
Collapse
Affiliation(s)
- Matthieu Mazaleyrat
- Service de chirurgie orthopédique et traumatologique, hôpital Trousseau, avenue de la république, CHRU de Tours, 37170 Chambray-lès-Tours, France
| | - Luc Favard
- Service de chirurgie orthopédique et traumatologique, hôpital Trousseau, avenue de la république, CHRU de Tours, 37170 Chambray-lès-Tours, France
| | - Pascal Boileau
- Institut universitaire Locomoteur et du Sport, CHU Nice, hôpital Pasteur 2, 30, voie Romaine, 06000 Nice, France
| | - Julien Berhouet
- Service de chirurgie orthopédique et traumatologique, hôpital Trousseau, avenue de la république, CHRU de Tours, 37170 Chambray-lès-Tours, France.
| |
Collapse
|
49
|
Nguyen NTV, Martinez-Catalan N, Songy CE, Sanchez-Sotelo J. Radiological humeral adaptative changes five years after anatomical total shoulder arthroplasty using a standard-length cementless hydroxyapatite-coated humeral component. Bone Joint J 2021; 103-B:958-963. [PMID: 33934651 DOI: 10.1302/0301-620x.103b5.bjj-2020-1619.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The purpose of this study was to report bone adaptive changes after anatomical total shoulder arthroplasty (TSA) using a standard-length hydroxyapatite (HA)-coated humeral component, and to report on a computer-based analysis of radiographs to determine changes in peri-implant bone density objectively. METHODS A total of 44 TSAs, performed between 2011 and 2014 using a cementless standard-length humeral component proximally coated with HA, were included. There were 23 males and 21 females with a mean age of 65 years (17 to 65). All shoulders had good quality radiographs at six weeks and five years postoperatively. Three observers graded bone adaptive changes. All radiographs were uploaded into a commercially available photographic software program. The grey value density of humeral radiological areas was corrected to the grey value density of the humeral component and compared over time. RESULTS Stress shielding was graded as mild in 14 shoulders and moderate in three; the greater tuberosity was the predominant site for stress shielding. The mean metaphyseal and diaphyseal fill-fit ratios were 0.56 (SD 0.1) and 0.5 (SD 0.07), respectively. For shoulders with no radiologically visible stress shielding, the mean decrease in grey value in zones 1 and 7 was 20%, compared with 38% in shoulders with radiologically visible stress shielding. CONCLUSION The rate of moderate stress shielding was 7%, five years after implantation of a cementless standard-length HA-coated humeral component. Clinical observation of stress shielding identified on radiographs seems to represent a decrease in grey value of 25% or more. Cite this article: Bone Joint J 2021;103-B(5):958-963.
Collapse
|
50
|
Holschen M, Kiriazis A, Bockmann B, Schulte TL, Witt KA, Steinbeck J. Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:307-315. [PMID: 33880654 DOI: 10.1007/s00590-021-02976-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Accepted: 04/12/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Reverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155° and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135° in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. MATERIAL AND METHODS For this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m = 11, f = 10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155° humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m = 5, f = 16; mean age 72 years; mean follow-up 34 months) were treated with a 135° humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. RESULTS The clinical results were similar in both groups concerning the Constant Score (group A = 56.3 vs. group B = 56.1; p = 0.733), the adjusted CS (group A = 70.4% vs. group B = 68.3%; p = 0.589) and the SSV (group A = 72.0% vs. group B = 75.2%; p = 0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction = 98° versus 97.9°, p = 0.655; external rotation with the arm at side = 17.9° versus 18.7°, p = 0.703; external rotation with the arm positioned in 90° of abduction = 22.3° versus 24.7°, p = 0.524; forward flexion = 116.1° versus 116.7°, p = 0.760. The rate of scapular notching was higher (p = 0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A = 48% vs. group B = 38%). CONCLUSION Theoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155° and a standard glenosphere, implants with a humeral inclination angle of 135° and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Malte Holschen
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany. .,Raphaelsklinik, Münster, Germany.
| | | | - Benjamin Bockmann
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Tobias L Schulte
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Kai-Axel Witt
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany
| | - Jörn Steinbeck
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany
| |
Collapse
|