1
|
Rahman AMA, Ransangan J, Subbiah VK. Improvements to the Rapid Detection of the Marine Pathogenic Bacterium, Vibrio harveyi, Using Loop-Mediated Isothermal Amplification (LAMP) in Combination with SYBR Green. Microorganisms 2022; 10:microorganisms10122346. [PMID: 36557599 PMCID: PMC9786892 DOI: 10.3390/microorganisms10122346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 11/23/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022] Open
Abstract
The common methods that are presently used to identify Vibrio harveyi include microscopic examination and biochemical, immunological and PCR-based assays. These methods require technical expertise, and can be time-consuming. A rapid method is required for the high-throughput screening of large number of samples. As such, we have developed a rapid, simple yet sensitive and specific detection method based on the use of the loop-mediated isothermal amplification (LAMP) of DNA. A set of six primers, i.e., two outer, two inner and two loop primers, was designed based on the in silico analysis of a large pool of 39 strains of the toxR gene sequence of V. harveyi. The addition of the loop primers decreased the reaction time of the LAMP by more than half. Furthermore, with the application of SYBR Green, the result can be obtained as quickly as in 10 to 15 min without the need of gel electrophoresis. The specificity of the method primers was then determined by performing LAMP with Vibrio and non-Vibrio samples. LAMP has a greater sensitivity than PCR reaction. The sensitivity of PCR was at 0.6 pg concentration of V. harveyi recombinant plasmid DNA standard, while LAMP was able to detect lower amounts even at 0.6 fg. The development of the LAMP assay will provide a valuable tool for the high-throughput rapid detection of V. harveyi contamination both in laboratories and in the field.
Collapse
Affiliation(s)
- Ahmad Mukhlis Abdul Rahman
- Biotechnology Research Institute, Universiti Malaysia Sabah, Jln UMS, Kota Kinabalu 88400, Sabah, Malaysia
- Faculty of Chemical Engineering & Technology, Uniciti Alam Campus, Universiti Malaysia Perlis, Sg. Chuchuh, Padang Besar 02100, Perlis, Malaysia
| | - Julian Ransangan
- Borneo Marine Research Institute, Universiti Malaysia Sabah, Jln UMS, Kota Kinabalu 88400, Sabah, Malaysia
| | - Vijay Kumar Subbiah
- Biotechnology Research Institute, Universiti Malaysia Sabah, Jln UMS, Kota Kinabalu 88400, Sabah, Malaysia
- Correspondence:
| |
Collapse
|
2
|
Park JW. Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests. BIOSENSORS 2022; 12:bios12100857. [PMID: 36290994 PMCID: PMC9599884 DOI: 10.3390/bios12100857] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 05/03/2023]
Abstract
For the identification of nucleic acids, which are important biomarkers of pathogen-mediated diseases and viruses, the gold standard for NA-based diagnostic applications is polymerase chain reaction (PCR). However, the requirements of PCR limit its application as a rapid point-of-care diagnostic technique. To address the challenges associated with regular PCR, many isothermal amplification methods have been developed to accurately detect NAs. Isothermal amplification methods enable NA amplification without changes in temperature with simple devices, as well as faster amplification times compared with regular PCR. Of the isothermal amplifications, loop-mediated isothermal amplification (LAMP) is the most studied because it amplifies NAs rapidly and specifically. This review describes the principles of LAMP, the methods used to monitor the process of LAMP, and examples of biosensors that detect the amplicons of LAMP. In addition, current trends in the application of LAMP to smartphones and self-diagnosis systems for point-of-care tests are also discussed.
Collapse
Affiliation(s)
- Jee-Woong Park
- Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI Hub), Daegu 41061, Korea
| |
Collapse
|
3
|
Development of Colorimetric Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Detecting Feline Coronavirus. Animals (Basel) 2022; 12:ani12162075. [PMID: 36009664 PMCID: PMC9405184 DOI: 10.3390/ani12162075] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/30/2022] [Accepted: 08/10/2022] [Indexed: 11/17/2022] Open
Abstract
Simple Summary Feline coronavirus infecting domestic cats can cause feline infectious peritonitis (FIP), a fatal infectious disease. Several relevant clinical diagnoses and molecular methods are complicated and often ambiguous for veterinarians. In this work developed a rapid, sensitive, specific, and easy-to-visualize colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay with a novel LAMP primer set that has high specificity was developed using neutral red as an indicator dye. This proposed procedure could reliably detect FCoV RNA from effusion fluids comparable to the conventional PCR method. Considering these advantages, the RT-LAMP developed here has great potential on FIP-associated FCoV surveillance. Together with other sophisticated molecular diagnostic tools, this method can further be exploited in clinical laboratories to inspect suspected cats with effusive FIP. Abstract Feline infectious peritonitis (FIP) is a worldwide fatal disease caused by a mutant feline coronavirus (FCoV). Simple and efficient molecular detection methods are needed. Here, sensitive, specific, rapid, and reliable colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) was developed to detect the ORF1a/1b gene of FCoV from cats with suspected FIP using neutral red as an indicator. Novel LAMP primers were specifically designed based on the gene of interest. The isothermal assay could visually detect FCoV at 58 °C for 50 min. The RT-LAMP assay was highly specific and had no cross-reactivity with other related feline viruses. The detection limit of FCoV detection by RT-LAMP was 20 fg/µL. A blind clinical test (n = 81) of the developed RT-LAMP procedure was in good agreement with the conventional PCR method. In the light of its performance specificity, sensitivity, and easy visualization, this neutral-red-based RT-LAMP approach would be a fruitful alternative molecular diagnostic tool for veterinary inspection of FCoV when combined with nucleotide sequencing or specific PCR to affirm the highly virulent FIP-associated FCoV.
Collapse
|
4
|
Wang H, Wang S, Wang H, Liang Y, Jia Y, Li Z. Light Scattering Technology-Combined Ligation-Dependent Loop-Mediated Isothermal Amplification (LL-LAMP) for Sensitive Detection of RNA. ACS OMEGA 2022; 7:19957-19963. [PMID: 35721910 PMCID: PMC9202044 DOI: 10.1021/acsomega.2c01759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
Loop-mediated isothermal amplification (LAMP) has been widely used in nucleic acid assay because of its high specificity, sensitivity, and isothermal property. However, the complexity of amplification product detection is still a major challenge for its wide applications. Herein, we developed a light scattering technology-assisted, low-cost, and simple detection manner of LAMP products without expensive reagents and complicated instruments. Only needing to add a kind of strong acid to the amplification products, the amplification products can aggregate into large particles in a strongly acidic medium, and large particles can produce strong light scattering, which shows a good proportional relationship with the number of amplification products in a wide range. The proposed method shows excellent sensitivity and high specificity that can quantify RNA as low as 100 aM with a single-base resolution.
Collapse
|
5
|
Lee JE, Kim SA, Mun H, Kim SR, Ha KS, Shim WB. A rapid and colorimetric loop-mediated isothermal amplification (LAMP) based on HRP-mimicking molecular beacon for the detection of major 6 Listeria species in enoki mushroom. Food Control 2022. [DOI: 10.1016/j.foodcont.2021.108569] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
6
|
Daskou M, Tsakogiannis D, Alexopoulou DS, Dimitriou TG, Mossialos D, Amoutzias GD, Kottaridi C, Markoulatos P. A colorimetric IsoPCR for the rapid and sensitive visual detection of high-risk HPV16 in clinical samples with hydroxynaphthol blue. J Virol Methods 2021; 290:114072. [PMID: 33485938 DOI: 10.1016/j.jviromet.2021.114072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 11/04/2020] [Accepted: 01/16/2021] [Indexed: 01/06/2023]
Abstract
HPV16 infection is found in more than 50 % of cervical cancer cases worldwide, triggering the development of numerous molecular techniques for viral diagnosis. The present study focuses on the development of a colorimetric IsoPCR for HPV16 DNA detection. The methodology combines the advantages of PCR and LAMP, while the most significant aspect of the new established methodology is the visual detection of amplification products through hydroxynapthol blue dye, thus minimizing the time and labor needed. An experimental cut-off value was tested through reconstitution experiments, while the specificity was evaluated by assessing clinical samples. The analytical sensitivity of the new colorimetric IsoPCR was found to be 0.1 viral DNA copy per reaction, while the specificity was 100 % for the detection of HPV16 DNA. The assay enabled the amplification of viral DNA in cases with viral load lower than 1 copy. In conclusion, the new established colorimetric IsoPCR can be regarded as an attractive molecular tool that facilitates the specific, rapid and highly sensitive visual detection of HPV16 DNA even at the very early stages of viral infection.
Collapse
Affiliation(s)
- M Daskou
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece
| | - D Tsakogiannis
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece.
| | - D S Alexopoulou
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece
| | - T G Dimitriou
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece
| | - D Mossialos
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece
| | - G D Amoutzias
- Bioinformatics Laboratory, University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Biopolis, Larissa, Greece
| | - C Kottaridi
- Second Department of Pathology, Attikon University Hospital, National and Kapodistrian University of Athens, Chaidari, Athens, 12462, Greece; Department of Genetics, Development and Molecular Biology, School of Biology, Aristotle University of Thessaloniki, Thessaloniki, GR, 54124, Greece
| | - P Markoulatos
- University of Thessaly, School of Health Sciences, Department of Biochemistry & Biotechnology, Microbiology-Virology Laboratory, Biopolis, 41500, Larissa, Greece
| |
Collapse
|
7
|
Lau YL, Ismail I, Mustapa NI, Lai MY, Tuan Soh TS, Hassan A, Peariasamy KM, Lee YL, Chong YM, Sam IC, Goh PP. Real-time reverse transcription loop-mediated isothermal amplification for rapid detection of SARS-CoV-2. PeerJ 2020; 8:e9278. [PMID: 32547882 PMCID: PMC7275676 DOI: 10.7717/peerj.9278] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 05/12/2020] [Indexed: 12/17/2022] Open
Abstract
Background Highly sensitive real-time reverse transcription polymerase chain reaction (RT-qPCR) methods have been developed for the detection of SARS-CoV-2. However, they are costly. Loop-mediated isothermal amplification (LAMP) assay has emerged as a novel alternative isothermal amplification method for the detection of nucleic acid. Methods A rapid, sensitive and specific real-time reverse transcription LAMP (RT-LAMP) assay was developed for SARS-CoV-2 detection. Results This assay detected one copy/reaction of SARS-CoV-2 RNA in 30 min. Both the clinical sensitivity and specificity of this assay were 100%. The RT-LAMP showed comparable performance with RT-qPCR. Combining simplicity and cost-effectiveness, this assay is therefore recommended for use in resource resource-limited settings.
Collapse
Affiliation(s)
- Yee Ling Lau
- Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Ilyiana Ismail
- Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia
| | | | - Meng Yee Lai
- Department of Parasitology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | | | - Afifah Hassan
- Department of Pathology, Hospital Sungai Buloh, Selangor, Malaysia
| | | | - Yee Leng Lee
- Clinical Research Centre, Hospital Sungai Buloh, Selangor, Malaysia
| | - Yoong Min Chong
- Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - I-Ching Sam
- Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
| | - Pik Pin Goh
- Institute for Clinical Research (ICR), National Institutes of Health (NIH), Ministry of Health Malaysia, Putrajaya, Malaysia
| |
Collapse
|
8
|
Rahman HU, Yue X, Yu Q, Zhang W, Zhang Q, Li P. Current PCR-based methods for the detection of mycotoxigenic fungi in complex food and feed matrices. WORLD MYCOTOXIN J 2020. [DOI: 10.3920/wmj2019.2455] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Mycotoxins are toxic secondary fungal metabolites produced by certain types of filamentous fungi, such as Aspergillus, Fusarium, and Penicillium spp. Mycotoxigenic fungi and their produced mycotoxins are considered to be an important issue in food and feed safety due to their toxic effects like carcinogenicity, immunosuppression, neurotoxicity, nephrotoxicity, and hepatotoxicity on humans and animals. To boost the safety level of food and feedstuff, detection and identification of toxins are essential at critical control points across food and feed chains. Zero-tolerance policies by the European Union and other organizations about the extreme low level of tolerance of mycotoxins contamination in food and feed matrices have led to an increasing interest to design more sensitive, specific, rapid, cost-effective, and safer to use mycotoxigenic fungi detection technologies. Hence, many mycotoxigenic fungi detection technologies have been applied to measure and control toxins contamination in food and feed substrates. PCR-based mycotoxigenic fungi detection technologies, such as conventional PCR, real-time PCR, nested PCR, reverse transcriptase (RT)-PCR, loop-mediated isothermal amplification (LAMP), in situ PCR, polymerase chain reaction-denaturing gradient gel electrophoresis (PCR DGGE), co-operational PCR, multiplex PCR, DNA arrays, magnetic capture-hybridization (MCH)-PCR and restriction fragment length polymorphism (RFLP), would contribute to our understanding about different mycotoxigenic fungi detection approaches and will enhance our capability about mycotoxigenic fungi identification, isolation and characterization at critical control points across food and feed chains. We have assessed the principles, results, the limit of detection, and application of these PCR-based detection technologies to alleviate mycotoxins contamination problem in complex food and feed substrates. The potential application of these detection technologies can reduce mycotoxins in complex food and feed matrices.
Collapse
Affiliation(s)
- H. Ur Rahman
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China P.R
| | - X. Yue
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Laboratory of Quality & Safety Risk Assessment for Oilseeds Products, Wuhan, Ministry of Agriculture, Wuhan 430062, China P.R
| | - Q. Yu
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China P.R
- National Reference Laboratory for Agricultural Testing (Biotoxin), Wuhan 430062, China P.R
| | - W. Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Quality Inspection and Test Center for Oilseeds Products, Ministry of Agriculture, Wuhan 430062, China P.R
| | - Q. Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Laboratory of Quality & Safety Risk Assessment for Oilseeds Products, Wuhan, Ministry of Agriculture, Wuhan 430062, China P.R
| | - P. Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China P.R
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Wuhan 430062, China P.R
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture, Wuhan 430062, China P.R
- Laboratory of Quality & Safety Risk Assessment for Oilseeds Products, Wuhan, Ministry of Agriculture, Wuhan 430062, China P.R
- National Reference Laboratory for Agricultural Testing (Biotoxin), Wuhan 430062, China P.R
| |
Collapse
|
9
|
Lee JE, Mun H, Kim SR, Kim MG, Chang JY, Shim WB. A colorimetric Loop-mediated isothermal amplification (LAMP) assay based on HRP-mimicking molecular beacon for the rapid detection of Vibrio parahaemolyticus. Biosens Bioelectron 2020; 151:111968. [DOI: 10.1016/j.bios.2019.111968] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2019] [Revised: 11/21/2019] [Accepted: 12/14/2019] [Indexed: 12/20/2022]
|
10
|
Reuter C, Slesiona N, Hentschel S, Aehlig O, Breitenstein A, Csáki A, Henkel T, Fritzsche W. Loop-mediated amplification as promising on-site detection approach for Legionella pneumophila and Legionella spp. Appl Microbiol Biotechnol 2019; 104:405-415. [PMID: 31832709 DOI: 10.1007/s00253-019-10286-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 11/08/2019] [Accepted: 11/28/2019] [Indexed: 12/16/2022]
Abstract
Recently Legionella pneumophila is the main causative waterborne organism of severe respiratory infections. Additionally, other Legionella species are documented as human pathogens. In our work, we describe a rapid detection method which combines two advantages for sensitive and specific detection of the genus Legionella: the fast isothermal amplification method "Loop-mediated isothermal AMPlification" (LAMP), and a colorimetric detection method using the metal indicator hydroxynaphtol blue (HBN) which allows to determine an optical signal with a simple readout (with the naked eye). Moreover, we present two approaches for minimizing the assay volume using a stationary microchip LAMP and droplet digital-based LAMP (ddLAMP) as promising highly sensitive setups.
Collapse
Affiliation(s)
- Cornelia Reuter
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany.
| | - Nicole Slesiona
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Stefanie Hentschel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Oliver Aehlig
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | | | - Andrea Csáki
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Thomas Henkel
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| | - Wolfgang Fritzsche
- Leibniz Institute of Photonic Technology (Leibniz IPHT) Jena, Member of the Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Straße 9, 07745, Jena, Germany
| |
Collapse
|
11
|
One-step reverse transcription loop-mediated isothermal amplification: a simple, sensitive and rapid assay for detection of potato virus X in potato leaves and tubers. ACTA ACUST UNITED AC 2019. [DOI: 10.1007/s42360-019-00147-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
12
|
Thiessen LD, Neill TM, Mahaffee WF. Development of a quantitative loop-mediated isothermal amplification assay for the field detection of Erysiphe necator. PeerJ 2018; 6:e4639. [PMID: 29692952 PMCID: PMC5912203 DOI: 10.7717/peerj.4639] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 03/28/2018] [Indexed: 11/21/2022] Open
Abstract
Plant pathogen detection systems have been useful tools to monitor inoculum presence and initiate management schedules. More recently, a loop-mediated isothermal amplification (LAMP) assay was successfully designed for field use in the grape powdery mildew pathosystem; however, false negatives or false positives were prevalent in grower-conducted assays due to the difficulty in perceiving the magnesium pyrophosphate precipitate at low DNA concentrations. A quantitative LAMP (qLAMP) assay using a fluorescence resonance energy transfer-based probe was assessed by grape growers in the Willamette Valley of Oregon. Custom impaction spore samplers were placed at a research vineyard and six commercial vineyard locations, and were tested bi-weekly by the lab and by growers. Grower-conducted qLAMP assays used a beta-version of the Smart-DART handheld LAMP reaction devices (Diagenetix, Inc., Honolulu, HI, USA), connected to Android 4.4 enabled, Bluetooth-capable Nexus 7 tablets for output. Quantification by a quantitative PCR assay was assumed correct to compare the lab and grower qLAMP assay quantification. Growers were able to conduct and interpret qLAMP results; however, the Erysiphe necator inoculum quantification was unreliable using the beta-Smart-DART devices. The qLAMP assay developed was sensitive to one spore in early testing of the assay, but decreased to >20 spores by the end of the trial. The qLAMP assay is not likely a suitable management tool for grape powdery mildew due to losses in sensitivity and decreasing costs and portability for other, more reliable molecular tools.
Collapse
Affiliation(s)
- Lindsey D Thiessen
- Department of Botany and Plant Pathology, Oregon State University, Corvallis, OR, USA
| | - Tara M Neill
- Agricultural Research Service, United States Department of Agriculture, Corvallis, OR, USA
| | - Walter F Mahaffee
- Agricultural Research Service, United States Department of Agriculture, Corvallis, OR, USA
| |
Collapse
|
13
|
Zhong Q, Li K, Chen D, Wang H, Lin Q, Liu W. Rapid detection and subtyping of human papillomaviruses in condyloma acuminatum using loop-mediated isothermal amplification with hydroxynaphthol blue dye. Br J Biomed Sci 2018. [PMID: 29537347 DOI: 10.1080/09674845.2017.1411864] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Objective Condyloma acuminatum (CA) is a common, viral, sexually transmitted disease worldwide. Human papillomavirus (HPV) genotyping has important clinical implications for the treatment of CA. We developed a loop-mediated isothermal amplification (LAMP) method for the detection of HPV. Methods We collected 294 cervical scrape samples, including 30 HPV-6-positive, 30 HPV-11-positive, 22 HPV-16-positive, 20 HPV-42-positve, 30 HPV-43-positive, 20 HPV-44-positive and 142 HPV-negative samples. Tissues from 40 patients with a pathological diagnosis of CA were paraffin-embedded and analyzed by LAMP and Luminex. Hydroxynaphthol blue (HNB) and electrophoresis were used to detect the results of LAMP. Results LAMP and Luminex systems were compared in detecting six subtypes of HPV. LAMP reactions were specific for each subtype. The sensitivity of LAMP for HPV-6, as determined by the HNB indicator assay, was 1000 copies/tube. The kappa value between the two methods was 0.98 (HPV-6), 0.94 (HPV-11), 0.89 (HPV-43), 0.87 (HPV-42) 0.79 (HPV-16) and 0.68 (HPV-44). Among the 142 HPV-negative samples determined by the Luminex assay, HPV-6 was detected in eight and HPV-11 in one by LAMP. Among the 40 CA samples, the results of LAMP and Luminex were in agreement in 38 (95%). Conclusion The results of this study indicated that the LAMP assay with HNB is superior to the Luminex method in terms of sensitivity and specificity. The specificity of LAMP was 100% and the sensitivity of LAMP was 1000 copies/tube using HNB. LAMP is therefore a useful, quick and accurate method for the clinical diagnosis of HPV subtypes.
Collapse
Affiliation(s)
- Q Zhong
- a Department of Central Laboratory , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,b Department of Laboratory Medicine , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,c Department of Laboratory Medicine , Shanghai Skin Disease Hospital, Tongji University , Shanghai , China
| | - K Li
- a Department of Central Laboratory , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,b Department of Laboratory Medicine , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China
| | - D Chen
- a Department of Central Laboratory , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,b Department of Laboratory Medicine , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China
| | - H Wang
- d Department of Laboratory Medicine , Huashan Hospital, Fudan University , Shanghai , China
| | - Q Lin
- e Department of Radiation Oncology , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China
| | - W Liu
- a Department of Central Laboratory , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,b Department of Laboratory Medicine , Shanghai Tenth People's Hospital, Tongji University , Shanghai , China.,c Department of Laboratory Medicine , Shanghai Skin Disease Hospital, Tongji University , Shanghai , China
| |
Collapse
|
14
|
Reverse transcriptase loop-mediated isothermal amplification for the detection of feline coronavirus. J Virol Methods 2017; 243:105-108. [PMID: 28109842 PMCID: PMC7113849 DOI: 10.1016/j.jviromet.2017.01.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Revised: 01/12/2017] [Accepted: 01/14/2017] [Indexed: 11/20/2022]
Abstract
The Feline coronavirus (FCoV) is the etiological agent of feline infectious peritonitis (FIP), a lethal disease of felids. The role of molecular methods is controversial for the diagnosis of FIP, while essential for the identification of the shedders. Thus, a fast and inexpensive method for the detection of FCoV could be beneficial, especially in multicat environments. A reverse transcription loop mediated isothermal amplification (RT-LAMP) assay was developed. RNA extraction and RT-nPCR for FCoV were performed on thirty-two samples (11 faeces, 9 blood, 8 effusions, and 4 lymph nodes) collected from 27 cats. Six RT-LAMP primers were designed from the same conserved region of RT-nPCR, and the assay was run at 63°C for one hour. Results were evaluated through both agarose gel run and hydroxynapthol blue (HNB) dye and then compared with RT-nPCR results for the assessment of sensitivity and specificity. The overall specificity was 100%, but the sensitivity was 50% and 54.5% for agarose gel and HNB respectively. Therefore, RT-LAMP seems optimal to confirm the presence of the virus, but not applicable to exclude it.
Collapse
|
15
|
Almasi MA, Almasi G. Loop Mediated Isothermal Amplification (LAMP) for Embryo Sex Determination in Pregnant Women at Eight Weeks of Pregnancy. J Reprod Infertil 2017; 18:197-204. [PMID: 28377900 PMCID: PMC5359858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND In human, SRY (sex-determining region of the Y chromosome) is the major gene for the testis-determining factor which is found in normal XY males and in the rare XX males, and it is absent in normal XX females and many XY females. There are several methods which can indicate a male genotype by the presence of the amplified product of SRY gene. The aim of this study was to identify the SRY gene for embryo sex determination in human during pregnancy using loop mediated isothermal amplification (LAMP) method. METHODS A total of 15 blood samples from pregnant women at eight weeks of pregnancy were collected, and Plasma DNA was extracted. LAMP assay was performed using DNA obtained for detection of SRY gene. Furthermore, colorimetric LAMP assay for rapid and easy detection of SRY gene was developed. RESULTS LAMP results revealed that the positive reaction was highly specific only with samples containing XY chromosomes, while no amplification was found in samples containing XX chromosomes. A total of 15 blood samples from pregnant women were seven male embryos (46.6%) and eight female embryos (53.4%). All used visual components in the colorimetric assay could successfully make a clear distinction between positive and negative ones. CONCLUSION The LAMP assay developed in this study is a valuable tool capable of monitoring the purity and detection of SRY gene for sex determination.
Collapse
Affiliation(s)
- Mohammad Amin Almasi
- Corresponding Author: Mohammad Amin Almasi, Young Researchers and Elites Club, North Tehran Branch, Islamic Azad University, Tehran, Iran E-mail:
| | | |
Collapse
|
16
|
Song J, Mauk MG, Hackett BA, Cherry S, Bau HH, Liu C. Instrument-Free Point-of-Care Molecular Detection of Zika Virus. Anal Chem 2016; 88:7289-94. [PMID: 27306491 PMCID: PMC4955015 DOI: 10.1021/acs.analchem.6b01632] [Citation(s) in RCA: 212] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Accepted: 06/16/2016] [Indexed: 11/28/2022]
Abstract
The recent outbreak of Zika virus (ZIKV) infection in the Americas and its devastating impact on fetal development have prompted the World Health Organization (WHO) to declare the ZIKV pandemic as a Public Health Emergency of International Concern. Rapid and reliable diagnostics for ZIKV are vital because ZIKV-infected individuals display no symptoms or nonspecific symptoms similar to other viral infections. Because immunoassays lack adequate sensitivity and selectivity and are unable to identify active state of infection, molecular diagnostics are an effective means to detect ZIKV soon after infection and throughout pregnancy. We report on a highly sensitive reverse-transcription loop-mediated, isothermal amplification (RT-LAMP) assay for rapid detection of ZIKV and its implementation in a simple, easy-to-use, inexpensive, point-of-care (POC) disposable cassette that carries out all the unit operations from sample introduction to detection. For thermal control of the cassette, we use a chemically heated cup without a need for electrical power. Amplification products are detected with leuco crystal violet (LCV) dye by eye without a need for instrumentation. We demonstrated the utility of our POC diagnostic system by detecting ZIKV in oral samples with sensitivity of 5 plaque-forming units (PFU) in less than 40 min. Our system is particularly suitable for resource-poor settings, where centralized laboratory facilities, funds, and trained personnel are in short supply, and for use in doctors' offices, clinics, and at home.
Collapse
Affiliation(s)
- Jinzhao Song
- Department
of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Michael G. Mauk
- Department
of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Brent A. Hackett
- Department
of Microbiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Sara Cherry
- Department
of Microbiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Haim H. Bau
- Department
of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Changchun Liu
- Department
of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
17
|
Rapid detection of Bombyx mori nucleopolyhedrovirus (BmNPV) by loop-mediated isothermal amplification assay combined with a lateral flow dipstick method. Mol Cell Probes 2015; 29:389-395. [DOI: 10.1016/j.mcp.2015.09.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 08/21/2015] [Accepted: 09/08/2015] [Indexed: 11/19/2022]
|
18
|
Shi C, Shen X, Niu S, Ma C. Innate Reverse Transcriptase Activity of DNA Polymerase for Isothermal RNA Direct Detection. J Am Chem Soc 2015; 137:13804-6. [PMID: 26474356 DOI: 10.1021/jacs.5b08144] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
RNA detection has become one of the most robust parts in molecular biology, medical diagnostics and drug discovery. Conventional RNA detection methods involve an extra reverse transcription step, which limits their further application for RNA rapid detection. We herein report a novel finding that Bst and Klenow DNA polymerases possess innate reverse transcriptase activities, so that the reverse transcription step and next amplification reaction can be combined to one step in isothermal RNA detection. We have demonstrated that Bst and Klenow DNA polymerases could be successfully used to reverse transcribe RNA within 125-nt length by real time RT-PCR and polyacrylamide gel electrophoresis (PAGE). Our findings will spur the development of a myriad of simple and easy to use RNA detection technologies for isothermal RNA direct detection. This will just meet the future needs of bioanalysis and clinical diagnosis to RNA rapid detection in POC settings and inspection and quarantine.
Collapse
Affiliation(s)
- Chao Shi
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, PR China
| | - Xiaotong Shen
- Shandong Provincial Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, PR China
| | - Shuyan Niu
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, PR China
| | - Cuiping Ma
- Shandong Provincial Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology , Qingdao 266042, PR China
| |
Collapse
|
19
|
Lau YL, Lai MY, Teoh BT, Abd-Jamil J, Johari J, Sam SS, Tan KK, AbuBakar S. Colorimetric Detection of Dengue by Single Tube Reverse-Transcription-Loop-Mediated Isothermal Amplification. PLoS One 2015; 10:e0138694. [PMID: 26384248 PMCID: PMC4575147 DOI: 10.1371/journal.pone.0138694] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Accepted: 09/02/2015] [Indexed: 11/18/2022] Open
Abstract
Dengue is usually diagnosed by isolation of the virus, serology or molecular diagnostic methods. Several commercial kits for the diagnosis of dengue are existing, but concerns have arisen regarding to the affordability and performance characteristics of these kits. Hence, the loop-mediated isothermal amplification (LAMP) is potentially ideal to be used especially in resource limited environments. Serum was collected from healthy donors and patients diagnosed with dengue infection. RNA extracted from the serum samples were tested by reverse-transcription-LAMP assay developed based on 3′-NCR gene sequences for DENV 1–4. Results were interpreted by a turbidity meter in real time or visually at the end of the assay. Sensitivity and specificity of RT-LAMP results were calculated and compared to qRT-PCR and ELISA. RT-LAMP is highly sensitive with the detection limit of 10 RNA copies for all serotypes. Dengue virus RNA was detected in all positive samples using RT-LAMP and none of the negative samples within 30–45 minutes. With continuing efforts in the optimization of this assay, RT-LAMP may provide a simple and reliable test for detecting DENV in areas where dengue is prevalent.
Collapse
Affiliation(s)
- Yee-Ling Lau
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Department of Parasitology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
- * E-mail:
| | - Meng-Yee Lai
- Tropical Infectious Diseases Research and Education Centre (TIDREC), Department of Parasitology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Boon-Teong Teoh
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Juraina Abd-Jamil
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Jefree Johari
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Sing-Sin Sam
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Kim-Kee Tan
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Sazaly AbuBakar
- Tropical Infectious Diseases Research and Education Center (TIDREC), Department of Medical Microbiology, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|
20
|
Jeong J, Cho SY, Lee WH, Lee KJ, Ju HJ. Development of a Rapid Detection Method for Potato virus X by Reverse Transcription Loop-Mediated Isothermal Amplification. THE PLANT PATHOLOGY JOURNAL 2015; 31:219-25. [PMID: 26361470 PMCID: PMC4564147 DOI: 10.5423/ppj.oa.03.2015.0044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 05/05/2015] [Accepted: 05/10/2015] [Indexed: 05/10/2023]
Abstract
The primary step for efficient control of viral diseases is the development of simple, rapid, and sensitive virus detection. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been used to detect viral RNA molecules because of its simplicity and high sensitivity for a number of viruses. RT-LAMP for the detection of Potato virus X (PVX) was developed and compared with conventional reverse transcription polymerase chain reaction (RT-PCR) to demonstrate its advantages over RT-PCR. RT-LAMP reactions were conducted with or without a set of loop primers since one out of six primers showed PVX specificity. Based on real-time monitoring, RT-LAMP detected PVX around 30 min, compared to 120 min for RT-PCR. By adding a fluorescent reagent during the reaction, the extra step of visualization by gel electrophoresis was not necessary. RT-LAMP was conducted using simple inexpensive instruments and a regular incubator to evaluate whether RNA could be amplified at a constant temperature instead of using an expensive thermal cycler. This study shows the potential of RT-LAMP for the diagnosis of viral diseases and PVX epidemiology because of its simplicity and rapidness compared to RT-PCR.
Collapse
Affiliation(s)
- Joojin Jeong
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Sang-Yun Cho
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Wang-Hyu Lee
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Kui-jae Lee
- Division of Biotechnology, Chonbuk National University, Iksan 570-752,
Korea
- Plant Medicinal Research Center, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| | - Ho-Jong Ju
- Department of Agricultural Biology, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
- Plant Medicinal Research Center, College of Agriculture & Life Sciences, Chonbuk National University, Jeonju-si 561-756,
Korea
| |
Collapse
|
21
|
Wang DG, Brewster JD, Paul M, Tomasula PM. Two methods for increased specificity and sensitivity in loop-mediated isothermal amplification. Molecules 2015; 20:6048-59. [PMID: 25853320 PMCID: PMC6272222 DOI: 10.3390/molecules20046048] [Citation(s) in RCA: 128] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2015] [Revised: 03/22/2015] [Accepted: 04/01/2015] [Indexed: 11/16/2022] Open
Abstract
The technique of loop-mediated isothermal amplification (LAMP) utilizes four (or six) primers targeting six (or eight) regions within a fairly small segment of a genome for amplification, with concentration higher than that used in traditional PCR methods. The high concentrations of primers used leads to an increased likelihood of non-specific amplification induced by primer dimers. In this study, a set of LAMP primers were designed targeting the prfA gene sequence of Listeria monocytogenes, and dimethyl sulfoxide (DMSO) as well as Touchdown LAMP were employed to increase the sensitivity and specificity of the LAMP reactions. The results indicate that the detection limit of this novel LAMP assay with the newly designed primers and additives was 10 fg per reaction, which is ten-fold more sensitive than a commercial Isothermal Amplification Kit and hundred-fold more sensitive than previously reported LAMP assays. This highly sensitive LAMP assay has been shown to detect 11 strains of Listeria monocytogenes, and does not detect other Listeria species (including Listeria innocua and Listeria invanovii), providing some advantages in specificity over commercial Isothermal Amplification Kits and previously reported LAMP assay.
Collapse
Affiliation(s)
- De-Guo Wang
- Henan Postdoctoral Research Base, Food and Bioengineering College, Xuchang University, Xuchang 461000, China.
| | - Jeffrey D Brewster
- Eastern Regional Research Center, Agricultural Research Service, United States Department of Agriculture, Wyndmoor, PA 19038, USA.
| | - Moushumi Paul
- Eastern Regional Research Center, Agricultural Research Service, United States Department of Agriculture, Wyndmoor, PA 19038, USA.
| | - Peggy M Tomasula
- Eastern Regional Research Center, Agricultural Research Service, United States Department of Agriculture, Wyndmoor, PA 19038, USA.
| |
Collapse
|
22
|
Almasi MA, Aghapour-Ojaghkandi M, Bagheri K, Ghazvini M, Hosseyni-Dehabadi SM. Comparison and evaluation of two diagnostic methods for detection of npt II and GUS genes in Nicotiana tabacum. Appl Biochem Biotechnol 2015; 175:3599-616. [PMID: 25820356 DOI: 10.1007/s12010-015-1529-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2014] [Accepted: 01/26/2015] [Indexed: 11/24/2022]
Abstract
To diminish the time required for some diagnostic assays including polymerase chain reaction (PCR), loop-mediated isothermal amplification (LAMP) and also a visual detection protocol on the basis of npt II and GUS genes in transgenic tobacco plants were used. Agrobacterium tumefaciens-mediated transformation of Nicotiana tabacum leaf discs was performed with plant transformation vector of pBI 121. From kanamycin-resistant plants selected by their antibiotic resistance, four plants were selected for DNA isolation. Presence of the transgene was confirmed in the transformants by PCR and LAMP. In this regard, all LAMP and PCR primers were designed on the basis of the gene sequences of npt II and GUS. The LAMP assay was applied for direct detection of gene marker from plant samples without DNA extraction steps (direct LAMP assay). Also, a novel colorimetric LAMP assay for rapid and easy detection of npt II and GUS genes was developed here, its potential compared with PCR assay. The LAMP method, on the whole, had the following advantages over the PCR method: easy detection, high sensitivity, high efficiency, simple manipulation, safety, low cost, and user friendly.
Collapse
Affiliation(s)
- Mohammad Amin Almasi
- Young Researchers and Elite Club, North Tehran Branch, Islamic Azad University, Tehran, Iran,
| | | | | | | | | |
Collapse
|
23
|
Development of loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Penicillium nordicum in dry-cured meat products. Int J Food Microbiol 2015; 202:42-7. [PMID: 25771218 DOI: 10.1016/j.ijfoodmicro.2015.02.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 02/05/2015] [Accepted: 02/18/2015] [Indexed: 11/21/2022]
Abstract
The need of powerful diagnostic tools for rapid, simple, and cost-effective detection of food-borne fungi has become very important in the area of food safety. Currently, several isothermal nucleic acid amplification methods have been developed as an alternative to PCR-based analyses. Loop-mediated isothermal amplification (LAMP) is one of these innovative methods; it requires neither gel electrophoresis to separate and visualize the products nor expensive laboratory equipment and it has been applied already for detection of pathogenic organisms. In the current study, we developed a LAMP assay for the specific detection of Penicillium nordicum, the major causative agent of ochratoxin A contamination in protein-rich food, especially dry-cured meat products. The assay was based on targeting otapksPN gene, a key gene in the biosynthesis of ochratoxin A (OTA) in P. nordicum. Amplification of DNA during the reaction was detected directly in-tube by color transition of hydroxynaphthol blue from violet to sky blue, visible to the naked eye, avoiding further post amplification analyses. Only DNAs isolated from several P. nordicum strains led to positive results and no amplification was observed from non-target OTA and non OTA-producing strains. The assay was able to detect down to 100 fg of purified targeted genomic DNA or 10(2) conidia/reaction within 60 min. The LAMP assay for detection and identification of P. nordicum was combined with a rapid DNA extraction method set up on serially diluted conidia, providing an alternative rapid, specific and sensitive DNA-based method suitable for application directly "on-site", notably in key steps of dry-cured meat production.
Collapse
|
24
|
Zhang H, Liu Y, Gao J, Zhen J. A sensitive SERS detection of miRNA using a label-free multifunctional probe. Chem Commun (Camb) 2015; 51:16836-9. [DOI: 10.1039/c5cc06225j] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
A novel surface enhanced Raman scattering (SERS) detection method is fabricated for miRNA based on a smart multifunctional probe for dual cyclical nucleic acid strand-displacement polymerization (CNDP).
Collapse
Affiliation(s)
- Hao Zhang
- Department of Chemistry
- Qilu University of Technology
- Jinan 250353
- China
| | - Yu Liu
- Department of Chemistry
- Qilu University of Technology
- Jinan 250353
- China
| | - Jian Gao
- Department of Chemistry
- Qilu University of Technology
- Jinan 250353
- China
| | - Junhui Zhen
- School of Medicine
- Shandong University
- Jinan 250012
- China
| |
Collapse
|
25
|
Hu Y, Jia H, Wang Y, Cheng Y, Li Z. Sensitive quantification of messenger RNA with a real-time ligase chain reaction by using a ribonucleotide-modified DNA probe. Chem Commun (Camb) 2014; 50:13093-5. [DOI: 10.1039/c4cc05102e] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
26
|
Comparison and evaluation of three diagnostic methods for detection of beet curly top virus in sugar beet using different visualizing systems. Appl Biochem Biotechnol 2014; 173:1836-48. [PMID: 24894659 DOI: 10.1007/s12010-014-0970-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Accepted: 05/16/2014] [Indexed: 10/25/2022]
Abstract
To diminish the time required for some diagnostic assays including polymerase chain reaction (PCR), loop-mediated isothermal amplification (LAMP; due to mainly DNA extraction step) and also triple antibody sandwich enzyme-linked immunosorbent assay (TAS-ELISA) into a minimum level, an innovative immunocapture LAMP (IC-LAMP) and immunocapture PCR (IC-PCR) protocol on the basis of beet curly top virus (BCTV) genome was used and optimized. TAS-ELISA was employed first to validate the existence of the virus. All six IC-LAMP primers (i.e. forward outer primer (F3), backward outer primer (B3), forward inner primer (FIP), backward inner primer (BIP), loop forward (LF) and loop backward (LB)) together with IC-PCR primers were designed on the basis of the replication-associated protein (rep) gene (GenBank accession AF379637.1) of BCTV genome. Also, a novel colorimetric IC-LAMP assay for rapid and easy detection of BCTV was developed here, its potential compared with TAS-ELISA and IC-PCR assays. The method, on the whole, had the following advantages over the two mentioned procedures: (i) fascinatingly, no need of DNA extraction; (ii) no requirement of expensive and sophisticated tools for amplification and detection; (iii) no post-amplification treatment of the amplicons and (iv) a flexible and easy detection approach, which is visually detected by naked eyes using diverse visual dyes.
Collapse
|
27
|
Mohon AN, Elahi R, Khan WA, Haque R, Sullivan DJ, Alam MS. A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria. Acta Trop 2014; 134:52-7. [PMID: 24613155 PMCID: PMC7117200 DOI: 10.1016/j.actatropica.2014.02.016] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 02/12/2014] [Accepted: 02/20/2014] [Indexed: 11/03/2022]
Abstract
Introduction of Hydroxy Nepthol Blue (HNB) has lead easy and simple naked eye visualization of the LAMP amplicons. The new primer set was found to be 99.1% sensitive and 99% specific in comparison with microscopy. In comparison with Real Time PCR, sensitivity was 98.1% along with 100% specificity. This new method can detect at least five parasite per μL of blood.
Molecular diagnosis of malaria by nucleotide amplification requires sophisticated and expensive instruments, typically found only in well-established laboratories. Loop-mediated isothermal amplification (LAMP) has provided a new platform for an easily adaptable molecular technique for molecular diagnosis of malaria without the use of expensive instruments. A new primer set has been designed targeting the 18S rRNA gene for the detection of Plasmodium falciparum in whole blood samples. The efficacy of LAMP using the new primer set was assessed in this study in comparison to that of a previously described set of LAMP primers as well as with microscopy and real-time PCR as reference methods for detecting P. falciparum. Pre-addition of hydroxy napthol blue (HNB) in the LAMP reaction caused a distinct color change, thereby improving the visual detection system. The new LAMP assay was found to be 99.1% sensitive compared to microscopy and 98.1% when compared to real-time PCR. Meanwhile, its specificity was 99% and 100% in contrast to microscopy and real-time PCR, respectively. Moreover, the LAMP method was in very good agreement with microscopy and real-time PCR (0.94 and 0.98, respectively). This new LAMP method can detect at least 5 parasites/μL of infected blood within 35 min, while the other LAMP method tested in this study, could detect a minimum of 100 parasites/μL of human blood after 60 min of amplification. Thus, the new method is sensitive and specific, can be carried out in a very short time, and can substitute PCR in healthcare clinics and standard laboratories.
Collapse
|
28
|
Rosa ACG, Ferreira HL, Gomes DE, Táparo CV, Cardoso TC. Isolation and molecular characterization of Brazilian turkey reovirus from immunosuppressed young poults. Arch Virol 2013; 159:1453-7. [PMID: 24327096 PMCID: PMC7086608 DOI: 10.1007/s00705-013-1947-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 11/01/2013] [Indexed: 11/27/2022]
Abstract
In this study, we investigated turkey reovirus (TReoV) in tissue samples from young birds, aged 15 days. RT-PCR for TReoV detected 3.3 % positive samples and TReoV was successfully isolated in Vero cells. Histological analysis of positive bursa of Fabricius (BF) revealed atrophied follicles and lymphocyte depletion. The number of CD8+, CD4+ and IgM+ cells was lower in infected BF. Phylogenetic analysis based on S3 gene showed that the Brazilian TReoV isolates clustered in a single group with 98-100 % similarity to TReoV strains circulating in the United States. This is the first indication that TReoV infection may be a contributing factor to immunosuppression in young birds.
Collapse
Affiliation(s)
- Ana Carolina G. Rosa
- Laboratório de Virologia, Faculdade de Medicina Veterinária, University of São Paulo State, Rua Clóvis Pestana, 793, Araçatuba, SP CEP 16050-680 Brazil
| | - Helena Lage Ferreira
- Departamento de Medicina Veterinária, FZEA-USP, Av. Duque de Caxias Norte, 225, Pirassununga, SP CEP 13635-900 Brazil
| | - Deriane Elias Gomes
- Laboratório de Virologia, Faculdade de Medicina Veterinária, University of São Paulo State, Rua Clóvis Pestana, 793, Araçatuba, SP CEP 16050-680 Brazil
| | - Cilene Vidovix Táparo
- Laboratório de Virologia, Faculdade de Medicina Veterinária, University of São Paulo State, Rua Clóvis Pestana, 793, Araçatuba, SP CEP 16050-680 Brazil
| | - Tereza Cristina Cardoso
- Laboratório de Virologia, Faculdade de Medicina Veterinária, University of São Paulo State, Rua Clóvis Pestana, 793, Araçatuba, SP CEP 16050-680 Brazil
- Departamento de Apoio, Produção e Saúde Animal, Curso de Medicina Veterinária, Rua Clóvis Pestana, 793, Araçatuba, SP CEP 16050-680 Brazil
| |
Collapse
|
29
|
|
30
|
Xu J, Cao L, Su L, Dong N, Yu M, Ju J. A new accurate assay for Coxsackievirus A 16 by fluorescence detection of isothermal RNA amplification. J Virol Methods 2013; 193:459-62. [PMID: 23872269 DOI: 10.1016/j.jviromet.2013.07.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2012] [Revised: 06/30/2013] [Accepted: 07/10/2013] [Indexed: 11/24/2022]
Abstract
Coxsackievirus A 16 (CA16) is one of the most common causes of hand, foot, and mouth disease (HFMD) worldwide. Without a vaccine or antiviral drug early, rapid, and accurate detection is critical for preventing and controlling HFMD. A simultaneous amplification and testing (SAT) assay was developed for detecting CA16 based on isothermal RNA amplification with fluorescence using standard, real-time PCR equipment. Primers and probes were designed to target the VP1 region of CA16. Virus strains and clinical specimens were used to evaluate the diagnostic performance characteristics of the assay. The assay detected as few as 10 copies of CA16 RNA transcripts. Using real-time PCR plus sequencing as the reference standard, the sensitivity and specificity of the SAT-CA16 assay were 100% and 99.2%, respectively. These findings indicate that SAT-CA16 is a rapid and reliable method for detecting CA16.
Collapse
Affiliation(s)
- Jin Xu
- Laboratory Medicine Center, Children's Hospital of Fudan University, Shanghai 201102, China.
| | | | | | | | | | | |
Collapse
|
31
|
Almasi MA, Erfan Manesh M, Jafary H, Dehabadi SMH. Visual detection of Potato Leafroll virus by loop-mediated isothermal amplification of DNA with the GeneFinder™ dye. J Virol Methods 2013; 192:51-4. [PMID: 23680094 DOI: 10.1016/j.jviromet.2013.04.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Revised: 04/10/2013] [Accepted: 04/15/2013] [Indexed: 11/25/2022]
Abstract
The most common virus affecting potatoes in the field worldwide is Potato Leafroll virus (PLRV), belonging to the family Luteoviridae, genius Plerovirus. There are several molecular methods to detect PLRV including polymerase chain reaction (PCR), Multiplex AmpliDet RNA and double antibody sandwich ELISA (DAS-ELISA). But these techniques take a long time for 3h to two days, requiring sophisticated tools. The aim of this study was to reduce the time required to detect PLRV, using a newly designed loop-mediated isothermal amplification (LAMP) technique requiring only an ordinary water bath or thermoblock. PLRV RNA was extracted from overall 80 infected naturally potato leaves. A set of six novel primers for the LAMP reaction was designed according to the highly conserved sequence of the viral coat protein (CP) gene. LAMP was carried out under isothermal conditions, applying the Bst DNA polymerase enzyme; the LAMP products were detected visually using the GeneFinder™ florescence dye. A positive result using the GeneFinder™ dye was a color change from the original orange to green. Results confirmed LAMP with GeneFinder™ provides a rapid and safe assay for detection of PLRV. Since with other molecular methods, equipping laboratories with a thermocycler or expensive detector systems is unavoidable, this assay was found to be a simple, cost-effective molecular method that has the potential to replace other diagnostic methods in primary laboratories without the need for expensive equipment or specialized techniques. It can also be considered as a reliable alternative viral detection system in further investigations.
Collapse
Affiliation(s)
- Mohammad Amin Almasi
- Department of Agriculture and Plant Breeding, Faculty of Agriculture, Zanjan University, Zanjan, Iran
| | | | | | | |
Collapse
|
32
|
Cleavage-based signal amplification of RNA. Nat Commun 2013; 4:1493. [PMID: 23422661 DOI: 10.1038/ncomms2492] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2012] [Accepted: 01/15/2013] [Indexed: 01/04/2023] Open
|
33
|
Storari M, von Rohr R, Pertot I, Gessler C, Broggini GAL. Identification of ochratoxin A producing Aspergillus carbonarius and A. niger clade isolated from grapes using the loop-mediated isothermal amplification (LAMP) reaction. J Appl Microbiol 2013; 114:1193-200. [PMID: 23331959 DOI: 10.1111/jam.12139] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 11/23/2012] [Accepted: 01/14/2013] [Indexed: 11/29/2022]
Abstract
AIMS To develop two assays based on the loop-mediated isothermal amplification (LAMP) of DNA for the quick and specific identification of Aspergillus carbonarius and ochratoxigenic strains of the Aspergillus niger clade isolated from grapes. METHODS AND RESULTS Two sets of primers were designed based on the polyketide synthase genes involved or putatively involved in ochratoxin A (OTA) biosynthesis in A. carbonarius and A. niger clade. Hydroxynaphthol blue was used as indirect method to indicate DNA amplification. The limit of detection of both assays was comparable to that of a PCR reaction. Specificities of the reactions were tested using DNA from different black aspergilli isolated from grapes. The two LAMP assays were then used to identify A. carbonarius and ochratoxigenic A. niger and A. awamori grown in pure cultures without a prior DNA extraction. CONCLUSIONS The two LAMP assays permitted to quickly and specifically identify DNA from OTA-producing black aspergilli, as well as isolates grown in pure culture. SIGNIFICANCE AND IMPACT OF THE STUDY Monitoring vineyards for the presence of OTA-producing strains is part of the measures to minimize the occurrence of OTA in grape products. The two LAMP assays developed here could be potentially used to speed the screening process of vineyards for the presence of OTA-producing black aspergilli.
Collapse
Affiliation(s)
- M Storari
- Plant Pathology Group, Institute of Integrative Biology, ETH Zurich, Zürich, Switzerland
| | | | | | | | | |
Collapse
|
34
|
Qu D, Zhou H, Han J, Tao S, Zheng B, Chi N, Su C, Du A. Development of reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a diagnostic tool of Toxoplasma gondii in pork. Vet Parasitol 2012; 192:98-103. [PMID: 23146414 DOI: 10.1016/j.vetpar.2012.10.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2012] [Revised: 10/15/2012] [Accepted: 10/15/2012] [Indexed: 10/27/2022]
Abstract
A fast, sensitive and specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) method for the detection of Toxoplasma gondii (T. gondii) in pork was developed. In this study, we used a conserved sequence of 18s rRNA of Toxoplasma gondii to design primers for RT-LAMP test. The amplication was able to finish in 60 min under isothermal condition at 63°C by employing a set of six primers. The assay showed higher sensitivity than RT-PCR using T. gondii RNA as template. The RT-LAMP assay was also assessed for specificity and was found to precisely discriminate between positive and negative test samples. Furthermore, the assay correctly detected T. gondii from contaminated pork, and had the detect limit of 1 tachyzoite in 1g pork. This is the first report of a study which applied the RT-LAMP method to detect T. gondii from pork. As RT-LAMP requires very basic instruments and the results can be obtained by visual observation, this technique provides a simple and reliable tool for inspecting food which are T. gondii-contaminated.
Collapse
Affiliation(s)
- Daofeng Qu
- Food Safety Key Laboratory of Zhejiang Province, School of Food Science and Biotechnology, Zhejiang Gongshang University, Hangzhou 310035, China.
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Almasi MA, Moradi A, Nasiri J, Karami S, Nasiri M. Assessment of Performance Ability of Three Diagnostic Methods for Detection of Potato Leafroll Virus (PLRV) Using Different Visualizing Systems. Appl Biochem Biotechnol 2012; 168:770-84. [DOI: 10.1007/s12010-012-9818-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Accepted: 08/01/2012] [Indexed: 10/28/2022]
|
36
|
Wang X, Zhang Q, Zhang F, Ma F, Zheng W, Zhao Z, Bai Y, Zheng L. Visual detection of the human metapneumovirus using reverse transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye. Virol J 2012; 9:138. [PMID: 22838725 PMCID: PMC3487928 DOI: 10.1186/1743-422x-9-138] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Accepted: 07/06/2012] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Human metapneumovirus (hMPV) is a major cause of acute respiratory infections ranging from wheezing to bronchiolitis and pneumonia in children worldwide. The objective of this study is to develop a visual reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for the detection of hMPV and applied to the clinical samples. RESULTS In this study, visual RT-LAMP assay for hMPV was performed in one step with the addition of hydroxynaphthol blue (HNB), and were used to detect respiratory samples. Six primers, including two outer primers (F3 and B3), two inner primers (FIP, BIP) and two loop primers (LF and LB), were designed for hMPV N gene by the online software. Moreover, the RT-LAMP assay showed good specificity and no cross-reactivity was observed with human rhinovirus (HRV), human respiratory syncytial Virus (RSV), or influenza virus A/PR/8/34 (H1N1). The detection limit of the RT-LAMP assay was approximately ten viral RNA copies, lower than that of traditional reverse transcriptase polymerase chain reaction (RT-PCR) 100 RNA copies. In the 176 nasopharyngeal samples, 23 (13.1%) were conformed as hMPV positive by RT-LAMP, but 18 (10.2%) positive by RT-PCR. CONCLUSION Compared with conventional RT-PCR, the visual hMPV RT-LAMP assay performed well in the aspect of detect time, sensitivity, specificity and visibility. It is anticipated that the RT-LAMP will be used for clinical tests in hospital or field testing during outbreaks and in emergency.
Collapse
Affiliation(s)
- Xiang Wang
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Qian Zhang
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Fang Zhang
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Fenlian Ma
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Wenzhi Zheng
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Zhihui Zhao
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| | - Yinglong Bai
- Department of Children and Adolescent Health, China Medical University, North 2nd Road 92, Heping District, Shenyang, 110001, Peoples Republic of China
| | - Lishu Zheng
- State Key Laboratory for Molecular Virology and Genetic Engineering, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Ying-Xin Road 100, Xuan Wu District, Beijing, 100052, Peoples Republic of China
| |
Collapse
|
37
|
Development of a loop-mediated isothermal amplification assay for rapid detection of capripoxviruses. J Clin Microbiol 2012; 50:1613-20. [PMID: 22357504 DOI: 10.1128/jcm.06796-11] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Sheep pox (SP), goat pox (GP), and lumpy skin disease (LSD), caused by capripoxviruses (CaPVs), are economically important diseases of sheep, goats, and cattle, respectively. Here, we report the development of a loop-mediated isothermal amplification (LAMP) assay for rapid detection of CaPVs. LAMP primers were designed to target a conserved gene encoding the poly(A) polymerase small subunit (VP39) of CaPVs. Hydroxynaphthol blue (HNB) was incorporated to monitor assay progress by color change from violet when negative to sky blue when positive, and results were verified by agarose gel electrophoresis. The LAMP assay was shown to be highly specific for CaPVs, with no apparent cross-reactivity to other related viruses (near neighbors) or viruses that cause similar clinical signs (look-a-like viruses). The performance of LAMP was compared to that of a highly sensitive quantitative real-time PCR (qPCR) assay. LAMP and qPCR exhibited similar analytical sensitivities, with limits of detection of 3 and 8 viral genome copies, respectively. Diagnostic specificity was assessed on 36 negative specimens, including swabs and EDTA blood from control sheep, goats, and cattle. Diagnostic sensitivity was assessed on 275 specimens, including EDTA blood, swabs, and tissues from experimentally infected sheep, goats, and cattle. Overall agreement on diagnostic test results between the two assays was 90 to 95% for specificity and 89 to 100% for sensitivity. The LAMP assay described in this report is simple to use, inexpensive, highly sensitive, and particularly well suited for the diagnosis of capripox in less well equipped laboratories and in rural settings where resources are limited.
Collapse
|
38
|
Xia JF, Yan XF, Yu H, Qu D, Long JE. Simple and rapid detection of human enterovirus 71 by reverse-transcription and loop-mediated isothermal amplification: cryopreservation affected the detection ability. Diagn Microbiol Infect Dis 2011; 71:244-51. [PMID: 21899976 PMCID: PMC7127202 DOI: 10.1016/j.diagmicrobio.2011.07.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2011] [Revised: 07/16/2011] [Accepted: 07/26/2011] [Indexed: 11/25/2022]
Abstract
Human enterovirus 71 (EV71) is the primary pathogen of hand, foot, and mouth disease (HFMD). EV71 infection may lead to neurologic damage, with higher incidence of fatality compared with other HFMD pathogens. An effective drug or vaccine against EV71 infection is currently unavailable. It is desirable to determine the pathogen of HFMD accurately and quickly for early treatment. In the current study, reverse-transcription and loop-mediated isothermal amplification (RT-LAMP) technology were developed to detect EV71. The efficacy of detecting EV71 was compared with regular nested reverse-transcription polymerase chain reaction (RT-PCR). After detecting 108 clinical specimens, results showed that RT-LAMP can specifically detect EV71, but not Coxsackie virus A16, and exhibited a specificity of 100% and a sensitivity of 97.1%, which was higher than regular RT-PCR. The findings indicate that RT-LAMP is a practical method for EV71 diagnostic applications, particularly in small county institutes of medical service. The detection ability of RT-LAMP was significantly affected by cryopreservation as the clinical specimens were repeatedly subject to freezing and thawing treatments.
Collapse
Affiliation(s)
- Ju-Feng Xia
- Department of Medical Microbiology and Parasitology, Laboratory of Medical Microbiology, Shang Medical College of Fudan University, Shanghai 200032, PR China
| | | | | | | | | |
Collapse
|
39
|
Visual detection of high-risk human papillomavirus genotypes 16, 18, 45, 52, and 58 by loop-mediated isothermal amplification with hydroxynaphthol blue dye. J Clin Microbiol 2011; 49:3545-50. [PMID: 21865423 DOI: 10.1128/jcm.00930-11] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
A simple, rapid, sensitive, qualitative, colorimetric loop-mediated isothermal amplification (LAMP) with hydroxynaphthol blue dye (HNB) was established to detect high-risk human papillomavirus (HPV) genotypes 16, 18, 45, 52, and 58. All initial validation studies with the control DNA proved to be type specific. The colorimetric type-specific LAMP assay could achieve a sensitivity of 10 to 100 copies at 63°C for 65 min, comparable to that of real-time PCR. In order to evaluate the reliability of HPV type-specific LAMP, the assay was further evaluated with HPV DNAs from a panel of 294 clinical specimens whose HPV status was previously determined with a novel one-step typing method with multiplex PCR. The tested panel comprised 108 HPV DNA-negative samples and 186 HPV-DNA-positive samples of 14 genotypes. The results showed that the sensitivity of HPV type-specific LAMP for HPV types 16, 18, 45, 52, and 58 was 100%, 100%, 100%, 100%, and 100%, respectively, and the specificity was 100%, 98.5%, 100%, 98.8%, and 99.2%, respectively, compared with a novel one-step typing method with multiplex PCR. No cross-reactivity with other HPV genotypes was observed. In conclusion, this qualitative and colorimetric LAMP assay has potential usefulness for the rapid screening of HPV genotype 16, 18, 45, 52, and 58 infections, especially in resource-limited hospitals or rural clinics of provincial and municipal regions in China.
Collapse
|
40
|
Pyrc K, Milewska A, Potempa J. Development of loop-mediated isothermal amplification assay for detection of human coronavirus-NL63. J Virol Methods 2011; 175:133-6. [PMID: 21545810 PMCID: PMC7112811 DOI: 10.1016/j.jviromet.2011.04.024] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2011] [Revised: 04/18/2011] [Accepted: 04/20/2011] [Indexed: 11/24/2022]
Abstract
Human coronavirus NL63 was identified in 2004 in the Netherlands. Due to the high prevalence and world-wide distribution of this pathogen, it is essential to develop a sensitive and specific detection assay suitable for use in a routine diagnostic laboratory. Techniques based on PCR or real-time PCR are laborious and expensive. Detailed analysis of the HCoV-NL63 genome permitted the identification of a conserved nucleic acid sequential motif, which was sufficient for the design of a loop-mediated isothermal amplification (LAMP) assay. Evaluation of the method showed that the test is specific to HCoV-NL63 and that it does not cross-react with other respiratory viruses. The detection limit was found to be 1 copy of RNA template per reaction in cell culture supernatants and clinical specimens.
Collapse
Affiliation(s)
- Krzysztof Pyrc
- Microbiology Department, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Gronostajowa 7, 30-387 Krakow, Poland.
| | | | | |
Collapse
|