1
|
Abdel Moneim MM, Hamdy MMA. Green and High Throughput HPTLC Method for Simultaneous Estimation of Celecoxib and Tramadol Hydrochloride in their Newly Approved Analgesic Combination and Spiked Plasma with Dichromic Green and Blue Assessments. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1252:124434. [PMID: 39731971 DOI: 10.1016/j.jchromb.2024.124434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2024] [Revised: 12/05/2024] [Accepted: 12/18/2024] [Indexed: 12/30/2024]
Abstract
The FDA "Food and Drug Administration" recently approved a novel co-crystal formulation of Celecoxib (CEX) and Tramadol (TRM) for the treatment of adults suffering from moderate to severe pain in several conditions. This novel combination has advantages over co-administration of the two drugs individually as better patient compliance, synergism and lower therapeutic cost. This work presents the first "High performance Thin Layer Chromatographic" (HPTLC) quantitative analytical technique for CEX and TRM simultaneous assay in bulk, their new dosage form and plasma.The proposed HPTLC assay is based on separation of CEX and TRM on silica gel 60 F254 sheets followed by densitometric scanning at 270 nm. The plates' development was carried out using a mobile phase of ethyl acetate-methanol-ammonia (5:5:0.05, v/v). The two drugs showed linearity of 0.025-1 μg.band-1& for plasma analysis linearity range was 0.2-10 μg.mL-1plasma. The proposed chromatographic technique was validated and showed satisfying validation characteristics of linearity, selectivity, precision and accuracy. In addition, the assay was evaluated by AGREE, AGREEprep, ComplexMoGAPI and BAGI for greenness and blueness to ensure the method's environmental sustainability and its safety for routine quality control assay of this novel combination.
Collapse
Affiliation(s)
- Mona M Abdel Moneim
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Pharos University in Alexandria, Canal El Mahmoudia Street, Beside Green Plaza Complex 21648, Alexandria, Egypt.
| | - Mohamed M A Hamdy
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Pharos University in Alexandria, Canal El Mahmoudia Street, Beside Green Plaza Complex 21648, Alexandria, Egypt
| |
Collapse
|
2
|
Li W, Yang X, Wang D, Xie J, Wang S, Rong Z. A handheld fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of methamphetamine and tramadol. Talanta 2024; 277:126438. [PMID: 38897012 DOI: 10.1016/j.talanta.2024.126438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 05/23/2024] [Accepted: 06/14/2024] [Indexed: 06/21/2024]
Abstract
The escalating issue of drug abuse poses a significant threat to public health and societal stability worldwide. An on-site drug detection platform is vital for combating drug abuse and trafficking, as it eliminates the need for additional tools, extensive processes, or specialized training. Therefore, it is imperative to develop a fast, sensitive, non-invasive, and reliable multiplex drug testing platform. In this study, we have presented a silica core@dual quantum dot-shell nanocomposite (SI/DQD)-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive and simultaneous point-of-care (POC) detection of methamphetamine (MET) and tramadol (TR). A 3D-printed attachment was designed to integrate optical and electrical components, facilitating the miniaturization of the instrument and reducing both cost and complexity. The device's advanced hardware and effective fluorescence extraction algorithm with waveform reconstruction enable swift, automatic noise reduction and data analysis. SI/DQD nanocomposites were utilized as fluorescent nanotags in the LFIA strips due to their outstanding luminous efficiency and robustness. This LFIA platform achieves impressive detection limits (LODs) of 0.11 ng mL-1 for MET and 0.017 ng mL-1 for TR. The method has also successfully detected MET and TR in complex biological samples, demonstrating its practical application capabilities. The proposed fluorescent LFIA platform, based on SI/DQD technology, holds significant promise for the swift and accurate POC detection of these substances. Its affordability, compact size, and excellent analytical performance make it suitable for on-site drug testing, including at borders and roadside checks, and open up new possibilities for the design and implementation of drug testing methods.
Collapse
Affiliation(s)
- Weijia Li
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China
| | | | - Dongfeng Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China
| | - Jianwei Xie
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China.
| | - Shengqi Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| | - Zhen Rong
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| |
Collapse
|
3
|
Kokilambigai KS, Irina VM, Sheba Mariam KC, Adila K, Kathirvel S. Comprehensive overview of analytical and bioanalytical methodologies for the opioid analgesics - Tramadol and combinations. Anal Biochem 2024; 692:115579. [PMID: 38797485 DOI: 10.1016/j.ab.2024.115579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 05/09/2024] [Accepted: 05/23/2024] [Indexed: 05/29/2024]
Abstract
Synthetic opioids like Tramadol are used to treat mild to moderate pain. Its ability to relieve pain is about a tenth that of morphine. Furthermore, Tramadol shares similar effects on serotonin and norepinephrine to several antidepressants known as serotonin-norepinephrine reuptake inhibitors (SNRIs), such as venlafaxine and duloxetine. The present review paper discusses the recent developments in analytical methods for identifying drugs in pharmaceutical preparations and toxicological materials, such as blood, saliva, urine, and hair. In recent years, a wide variety of analytical instruments, including capillary electrophoresis, NMR, UV-visible spectroscopy, HPTLC, HPLC, LC-MS, GC, GC-MS, and electrochemical sensors, have been used for drug identification in pharmaceutical preparations and toxicological samples. The primary quantification techniques currently employed for its quantification in various matrices are highlighted in this research.
Collapse
Affiliation(s)
- K S Kokilambigai
- Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur 603203, Chengalpattu District, Tamil Nadu, India
| | - V M Irina
- Dr. Moopen's College of Pharmacy, Naseera Nagar, Meppadi PO, Wayanad, 673577, Kerala, India
| | - K C Sheba Mariam
- Department of Pharmaceutical Analysis, National College of Pharmacy, Manassery, Mukkam Post., Kozhikode, 673602, Kerala, India
| | - K Adila
- Department of Pharmaceutical Analysis, National College of Pharmacy, Manassery, Mukkam Post., Kozhikode, 673602, Kerala, India
| | - S Kathirvel
- Department of Pharmaceutical Analysis, National College of Pharmacy, Manassery, Mukkam Post., Kozhikode, 673602, Kerala, India.
| |
Collapse
|
4
|
Ramadan HS, Abdel Salam RA, Hadad GM, Belal F, Salim MM. First derivative synchronous spectrofluorimetric method for the simultaneous determination of tramadol and celecoxib in their dosage forms and human plasma. LUMINESCENCE 2024; 39:e4774. [PMID: 38757441 DOI: 10.1002/bio.4774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 02/20/2024] [Accepted: 05/03/2024] [Indexed: 05/18/2024]
Abstract
One of the most common features of many different clinical conditions is pain; hence, there is a crucial need for eliminating or reducing it to a tolerable level to retrieve physical, psychological and social functioning. A first derivative synchronous spectrofluorimetry technique is proposed for the simultaneous determination of celecoxib and tramadol HCl, a recent coformulation authorized for treating acute pain in adults. The method includes using synchronous spectrofluorimetry at ∆λ = 80 nm where tramadol HCl was determined using first derivative technique at λ = 230.2 nm, while celecoxib was determined at λ = 288.24 nm. The proposed method was successfully applied to their co-formulated dosage forms in addition to spiked human plasma and validated in agreement with the guidelines of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). The linear ranges were found to be 0.50-5.0 and 0.15-0.50, the limits of detection to be 0.088 and 0.011 and the limits of quantification to be 0.266 and 0.032 μg/ml for celecoxib and tramadol, respectively. Statistical analysis revealed no significant difference when compared with previously reported methods as evidenced by the values of the variance ratio F-test and Student t-test. The proposed method was successfully applied to commercial dosage forms and spiked human samples. Moreover, the greenness of the proposed method was investigated based on the analytical eco-scale approach, with the results showing an excellent green scale with a score of 95.
Collapse
Affiliation(s)
- Hesham Sameh Ramadan
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt
| | - Randa A Abdel Salam
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
| | - Ghada M Hadad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
| | - Fathalla Belal
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| | - Mohamed M Salim
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt
| |
Collapse
|
5
|
Lima CD, Magalhães de Almeida Melo L, Arantes LC, Conceição NDS, de França Schaffel I, Machado LL, de Queiroz Ferreira R, Pio Dos Santos WT. Simple and selective screening method for the synthetic cathinone MDPT in forensic samples using carbon nanofiber screen-printed electrodes. Talanta 2024; 269:125375. [PMID: 37977086 DOI: 10.1016/j.talanta.2023.125375] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/27/2023] [Accepted: 10/30/2023] [Indexed: 11/19/2023]
Abstract
3',4'-Methylenedioxy-N-tert-butylcathinone (MDPT), also known as tBuONE or D-Tertylone, is a synthetic cathinone (SC) frequently abused for recreational purposes due to its potent stimulant effects and similarity to illegal substances like methamphetamine and ecstasy. The structural diversity and rapid introduction of new SC analogs to the market poses significant challenges for law enforcement and analytical methods for preliminary screening of illicit drugs. In this work, we present, for the first time, the electrochemical detection of MDPT using screen-printed electrodes modified with carbon nanofibers (SPE-CNF). MDPT exhibited three electrochemical processes (two oxidations and one reduction) on SPE-CNF. The proposed method for MDPT detection was optimized in 0.2 mol L-1 Britton-Robinson buffer solution at pH 10.0 using differential pulse voltammetry (DPV). The SPE-CNF showed a high stability for electrochemical responses of all redox processes of MDPT using the same or different electrodes, with relative standard deviations less than 4.7% and 1.5% (N = 3) for peak currents and peak potentials, respectively. Moreover, the proposed method provided a wide linear range for MDPT determination (0.90-112 μmol L-1) with low LOD (0.26 μmol L-1). Interference studies for two common adulterants, caffeine and paracetamol, and ten other illicit drugs, including amphetamine-like compounds and different SCs, showed that the proposed sensor is highly selective for the preliminarily identification of MDPT in seized forensic samples. Therefore, SPE-CNF with DPV can be successfully applied as a fast and simple screening method for MDPT identification in forensic analysis, addressing the significant challenges posed by the structural diversity of SCs.
Collapse
Affiliation(s)
- Camila Diana Lima
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Larissa Magalhães de Almeida Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Luciano Chaves Arantes
- Laboratório de Química e Física Forense, Instituto de Criminalística, Polícia Civil do Distrito Federal, 70610-907, Brasília, Distrito Federal, Brazil
| | - Nathália Dos Santos Conceição
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Izabela de França Schaffel
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Lara Lima Machado
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Rafael de Queiroz Ferreira
- Departamento de Química, Universidade Federal do Espírito Santo, Campus Goiabeiras, 29075910, Vitória, Espírito Santo, Brazil
| | - Wallans Torres Pio Dos Santos
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| |
Collapse
|
6
|
Ramadan HS, Salam RAA, Hadad GM, Belal F, Salim MM. Eco-friendly simultaneous multi-spectrophotometric estimation of the newly approved drug combination of celecoxib and tramadol hydrochloride tablets in its dosage form. Sci Rep 2023; 13:11716. [PMID: 37474596 PMCID: PMC10359252 DOI: 10.1038/s41598-023-38702-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 07/13/2023] [Indexed: 07/22/2023] Open
Abstract
Food and Drug Administration (FDA) recently approved co-formulated celecoxib and tramadol for the treatment of acute pain in adults. Three spectrophotometric methods were efficiently applied to estimate the co-formulated Celecoxib and Tramadol in their tablets; second derivative 2D-spectrophotometry technique (method I), induced dual-wavelength technique (method II) and dual-wavelength resolution technique (method III). The proposed methods were successfully validated following the International Council for Harmonisation (ICH) guidelines and statistically assessed based on the correlation coefficients, relative standard deviations as well as detection and quantitation limits. The obtained results revealed non-significant differences compared to the reported results as revealed by the variance ratio F test and Student t test. Moreover, the applied techniques were further assessed concerning their greenness based on the analytical eco-scale method revealing an excellent green scale with a final score of 95. The proposed spectrophotometric techniques could be applied for the routine analysis and quality control of the studied drugs in their dosage form.
Collapse
Affiliation(s)
- Hesham Sameh Ramadan
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt
| | - Randa A Abdel Salam
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
| | - Ghada M Hadad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt
| | - Fathalla Belal
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt
| | - Mohamed M Salim
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Horus University- Egypt, New Damietta, Egypt.
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt.
| |
Collapse
|
7
|
Zafar K, Wasim M, Fatima B, Hussain D, Mehmood R, Najam-Ul-Haq M. Quantification of tramadol and serotonin by cobalt nickel tungstate in real biological samples to evaluate the effect of analgesic drugs on neurotransmitters. Sci Rep 2023; 13:10239. [PMID: 37353529 PMCID: PMC10290146 DOI: 10.1038/s41598-023-37053-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/15/2023] [Indexed: 06/25/2023] Open
Abstract
In this work, CoNiWO4 nanocomposite was used as an electrochemical sensor for the simultaneous electrochemical detection of tramadol and serotonin. The nanocomposite was synthesized using a hydrothermal method and characterized via XRD, SEM, TGA, Zeta, UV, and FTIR. The sensor was developed by depositing CoNiWO4-NPs onto the glassy carbon electrode surface. Tramadol and serotonin were detected by employing cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and chronoamperometry. Analytes were detected at different pH, concentrations, and scan rates. The prepared sensor showed a 0-60 µM linear range, with a LOD of 0.71 µM and 4.29 µM and LOQ of 14.3 µM and 2.3 µM for serotonin and tramadol, respectively. Finally, the modified electrode (CoNiWO4-GCE) was applied to determine tramadol and serotonin in biological samples.
Collapse
Affiliation(s)
- Komal Zafar
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Muhammad Wasim
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Batool Fatima
- Department of Biochemistry, Bahauddin Zakariya University, Multan, 60800, Pakistan.
| | - Dilshad Hussain
- HEJ Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi, Karachi, 75270, Pakistan
| | | | - Muhammad Najam-Ul-Haq
- Institute of Chemical Sciences, Bahauddin Zakariya University, Multan, 60800, Pakistan.
| |
Collapse
|
8
|
Garkani Nejad F, Beitollahi H, Sheikhshoaie I. A UiO-66-NH 2 MOF/PAMAM Dendrimer Nanocomposite for Electrochemical Detection of Tramadol in the Presence of Acetaminophen in Pharmaceutical Formulations. BIOSENSORS 2023; 13:bios13050514. [PMID: 37232874 DOI: 10.3390/bios13050514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/22/2023] [Accepted: 04/04/2023] [Indexed: 05/27/2023]
Abstract
In this work, we prepared a novel electrochemical sensor for the detection of tramadol based on a UiO-66-NH2 metal-organic framework (UiO-66-NH2 MOF)/third-generation poly(amidoamine) dendrimer (G3-PAMAM dendrimer) nanocomposite drop-cast onto a glassy carbon electrode (GCE) surface. After the synthesis of the nanocomposite, the functionalization of the UiO-66-NH2 MOF by G3-PAMAM was confirmed by various techniques including X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), field emission-scanning electron microscopy (FE-SEM), and Fourier transform infrared (FT-IR) spectroscopy. The UiO-66-NH2 MOF/PAMAM-modified GCE exhibited commendable electrocatalytic performance toward the tramadol oxidation owing to the integration of the UiO-66-NH2 MOF with the PAMAM dendrimer. According to differential pulse voltammetry (DPV), it was possible to detect tramadol under optimized circumstances in a broad concentration range (0.5 μM-500.0 μM) and a narrow limit of detection (0.2 μM). In addition, the stability, repeatability, and reproducibility of the presented UiO-66-NH2 MOF/PAMAM/GCE sensor were also studied. The sensor also possessed an acceptable catalytic behavior for the tramadol determination in the co-existence of acetaminophen, with the separated oxidation potential of ΔE = 410 mV. Finally, the UiO-66-NH2 MOF/PAMAM-modified GCE exhibited satisfactory practical ability in pharmaceutical formulations (tramadol tablets and acetaminophen tablets).
Collapse
Affiliation(s)
- Fariba Garkani Nejad
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman, Kerman 76175-133, Iran
| |
Collapse
|
9
|
Affiliation(s)
- David Love
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| | - Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
- 70113 Street, N.W., Suite 750, Washington, DC, 20005-3967, USA
| |
Collapse
|
10
|
Ehirim T, Ozoemena OC, Mwonga PV, Haruna AB, Mofokeng TP, De Wael K, Ozoemena KI. Onion-like Carbons Provide a Favorable Electrocatalytic Platform for the Sensitive Detection of Tramadol Drug. ACS OMEGA 2022; 7:47892-47905. [PMID: 36591171 PMCID: PMC9798499 DOI: 10.1021/acsomega.2c05722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 10/17/2022] [Indexed: 06/17/2023]
Abstract
This work reports the first study on the possible application of nanodiamond-derived onion-like carbons (OLCs), in comparison with conductive carbon black (CB), as an electrode platform for the electrocatalytic detection of tramadol (an important drug of abuse). The physicochemical properties of OLCs and CB were determined using X-ray diffraction (XRD), Raman, scanning electron microscopy (SEM), Brunauer-Emmett-Teller (BET), and thermogravimetric analysis (TGA). The OLC exhibits, among others, higher surface area, more surface defects, and higher thermal stability than CB. From the electrochemical analysis (interrogated using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy), it is shown that an OLC-modified glassy carbon electrode (GCE-OLC) allows faster electron transport and electrocatalysis toward tramadol compared to a GCE-CB. To establish the underlying science behind the high performance of the OLC, theoretical calculations (density functional theory (DFT) simulations) were conducted. DFT predicts that OLC allows for weaker surface binding of tramadol (E ad = -26.656 eV) and faster kinetic energy (K.E. = -155.815 Ha) than CB (E ad = -40.174 eV and -305.322 Ha). The GCE-OLC shows a linear calibration curve for tramadol over the range of ∼55 to 392 μM, with high sensitivity (0.0315 μA/μM) and low limit of detection (LoD) and quantification (LoQ) (3.8 and 12.7 μM, respectively). The OLC-modified screen-printed electrode (SPE-OLC) was successfully applied for the sensitive detection of tramadol in real pharmaceutical formulations and human serum. The OLC-based electrochemical sensor promises to be useful for the sensitive and accurate detection of tramadol in clinics, quality control, and routine quantification of tramadol drugs in pharmaceutical formulations.
Collapse
Affiliation(s)
- Tobechukwu
J. Ehirim
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| | - Okoroike C. Ozoemena
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| | - Patrick V. Mwonga
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| | - Aderemi B. Haruna
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| | - Thapelo P. Mofokeng
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| | - Karolien De Wael
- A-Sense
Lab, Department of Bioscience Engineering, University of Antwerp, Groenenborgerlaan 171, 2020Antwerp, Belgium
- NANOlab
Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2020Antwerp, Belgium
| | - Kenneth I. Ozoemena
- Molecular
Sciences Institute, School of Chemistry, University of the Witwatersrand, Johannesburg2050, South Africa
| |
Collapse
|
11
|
Keshavarz S, Okoro OV, Hamidi M, Derakhshankhah H, Azizi M, Nabavi SM, Gholizadeh S, Amini SM, Shavandi A, Luque R, Samadian H. Synthesis, surface modifications, and biomedical applications of carbon nanofibers: Electrospun vs vapor-grown carbon nanofibers. Coord Chem Rev 2022; 472:214770. [PMID: 37600158 PMCID: PMC10438895 DOI: 10.1016/j.ccr.2022.214770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Engineered nanostructures are materials with promising properties, enabled by precise design and fabrication, as well as size-dependent effects. Biomedical applications of nanomaterials in disease-specific prevention, diagnosis, treatment, and recovery monitoring require precise, specific, and sophisticated approaches to yield effective and long-lasting favorable outcomes for patients. In this regard, carbon nanofibers (CNFs) have been indentified due to their interesting properties, such as good mechanical strength, high electrical conductivity, and desirable morphological features. Broadly speaking, CNFs can be categorized as vapor-grown carbon nanofibers (VGCNFs) and carbonized CNFs (e.g., electrospun CNFs), which have distinct microstructure, morphologies, and physicochemical properties. In addition to their physicochemical properties, VGCNFs and electrospun CNFs have distinct performances in biomedicine and have their own pros and cons. Indeed, several review papers in the literature have summarized and discussed the different types of CNFs and their performances in the industrial, energy, and composites areas. Crucially however, there is room for a comprehensive review paper dealing with CNFs from a biomedical point of view. The present work therefore, explored various types of CNFs, their fabrication and surface modification methods, and their applications in the different branches of biomedical engineering.
Collapse
Affiliation(s)
- Samaneh Keshavarz
- Medical Biotechnology Research Center, School of Paramedicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Oseweuba Valentine Okoro
- Université libre de Bruxelles (ULB), École polytechnique de Bruxelles, 3BIO-BioMatter, Avenue F.D. Roosevelt, 50 - CP 165/61, 1050 Brussels, Belgium
| | - Masoud Hamidi
- Medical Biotechnology Research Center, School of Paramedicine, Guilan University of Medical Sciences, Rasht, Iran
- Université libre de Bruxelles (ULB), École polytechnique de Bruxelles, 3BIO-BioMatter, Avenue F.D. Roosevelt, 50 - CP 165/61, 1050 Brussels, Belgium
| | - Hossein Derakhshankhah
- Pharmaceutical Sciences Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Mehdi Azizi
- Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Seyed Mohammad Nabavi
- Advanced Medical Pharma (BIOTEC), 82100, Benevento, Italy
- Nutringredientes Research Group, Federal Institute of Education, Science and Technology (IFCE), Brazil
| | - Shayan Gholizadeh
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, USA
| | - Seyed Mohammad Amini
- Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Amin Shavandi
- Université libre de Bruxelles (ULB), École polytechnique de Bruxelles, 3BIO-BioMatter, Avenue F.D. Roosevelt, 50 - CP 165/61, 1050 Brussels, Belgium
| | - Rafael Luque
- Departamento de Quimica Organica, Campus de Rabanales, Edificio Marie Curie (C-3), Ctra Nnal IV-A, Km 396, Cordoba, Spain
- Peoples Friendship University of Russia (RUDN University), 6 Miklukho Maklaya str., 117198, Moscow, Russian Federation
| | - Hadi Samadian
- Research Center for Molecular Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
- Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
12
|
Recent advances in morphology, aperture control, functional control and electrochemical sensors applications of carbon nanofibers. Anal Biochem 2022; 656:114882. [PMID: 36063917 DOI: 10.1016/j.ab.2022.114882] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/21/2022] [Accepted: 08/29/2022] [Indexed: 01/13/2023]
Abstract
Among many nanomaterials, electrospun carbon nanofibers (CNFs) have become one of the hot spots in nanoscience research because of their interesting physicochemical and biological properties such as large specific surface area, easy functionalization and biocompatibility. Polyacrylonitrile(PAN) has also become the most widely used precursor fiber for CNF manufacturing. In this paper, the latest advances in the synthesis of CNF by electrospinning were reviewed, including using template method, heat treatment, coaxial spinning technology to control the morphology and aperture, as well as the functionalization of electrospinning doped with chemical substances such as heteroatoms, nanoparticles (NPs), carbon nanotubes (CNTs) and grapheme (Gr), in order to further expand its application scope. The application of electrospun CNFs as electrochemical sensing platform for toxic and harmful substances in food and environment was also briefly introduced.
Collapse
|
13
|
A review on designing nanofibers with high porous and rough surface via electrospinning technology for rapid detection of food quality and safety attributes. Trends Food Sci Technol 2022. [DOI: 10.1016/j.tifs.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
14
|
Razlansari M, Ulucan-Karnak F, Kahrizi M, Mirinejad S, Sargazi S, Mishra S, Rahdar A, Díez-Pascual AM. Nanobiosensors for detection of opioids: A review of latest advancements. Eur J Pharm Biopharm 2022; 179:79-94. [PMID: 36067954 DOI: 10.1016/j.ejpb.2022.08.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 07/28/2022] [Accepted: 08/27/2022] [Indexed: 11/28/2022]
Abstract
Opioids are generally used as analgesics in pain treatment. Like many drugs, they have side effects when overdosing and causeaddiction problems.Illegal drug use and misuse are becoming a major concern for authorities worldwide; thus, it is critical to have precise procedures for detecting them in confiscated samples, biological fluids, and wastewaters. Routine blood and urine tests are insufficient for highly selective determinations and can cause cross-reactivities. For this purpose, nanomaterial-based biosensors are great tools to determine opioid intakes, continuously monitoring the drugs with high sensitivity and selectivity even at very low sample volumes.Nanobiosensors generally comprise a signal transducer nanostructure in which a biological recognition molecule is immobilized onto its surface. Lately, nanobiosensors have been extensively utilized for the molecular detection of opioids. The usage of novel nanomaterials in biosensing has impressed biosensing studies. Nanomaterials with a large surface area have been used to develop nanobiosensors with shorter reaction times and higher sensitivity than conventional biosensors. Colorimetric and fluorescence sensing methods are two kinds of optical sensor systems based on nanomaterials. Noble metal nanoparticles (NPs), such as silver and gold, are the most frequently applied nanomaterials in colorimetric techniques, owing to their unique optical feature of surface plasmon resonance. Despite the progress of an extensive spectrum of nanobiosensors over the last two decades, the future purpose of low-cost, high-throughput, multiplexed clinical diagnostic lab-on-a-chip instruments has yet to be fulfilled. In this review, a concise overview of opioids (such as tramadol and buprenorphine, oxycodone and fentanyl, methadone and morphine) is provided as well as information on their classification, mechanism of action, routine tests, and new opioid sensing technologies based on various NPs. In order to highlight the trend of nanostructure development in biosensor applications for opioids, recent literature examples with the nanomaterial type, target molecules, and limits of detection are discussed.
Collapse
Affiliation(s)
- Mahtab Razlansari
- Inorganic Chemistry Department, Faculty of Chemistry, Razi University, Kermanshah, Iran.
| | - Fulden Ulucan-Karnak
- Department of Medical Biochemistry, Institute of Health Sciences, Ege University, İzmir 35100, Turkey.
| | | | - Shekoufeh Mirinejad
- Cellular and Molecular Research Center, Research Institute of Cellular and Molecular Sciences in Infectious Diseases, Zahedan University of Medical Sciences, Zahedan 98167-43463, Iran.
| | - Saman Sargazi
- Cellular and Molecular Research Center, Research Institute of Cellular and Molecular Sciences in Infectious Diseases, Zahedan University of Medical Sciences, Zahedan 98167-43463, Iran.
| | - Sachin Mishra
- NDAC Centre, Kwangwoon University, Nowon-gu, Seoul, 01897, South Korea; RFIC Lab, Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul, 01897, South Korea.
| | - Abbas Rahdar
- Department of Physics, University of Zabol, Zabol, P.O. Box. 98613-35856, Iran.
| | - Ana M Díez-Pascual
- Universidad de Alcalá, Facultad de Ciencias, Departamento de Química Analítica, Química Física e Ingeniería Química, Ctra. Madrid-Barcelona, Km. 33.6, 28805 Alcalá de Henares, Madrid, Spain.
| |
Collapse
|
15
|
Sebokolodi TI, Sipuka DS, Muzenda C, Nkwachukwu OV, Nkosi D, Arotiba OA. Electrochemical detection of nicotine at a carbon Nanofiber-Poly(amidoamine) dendrimer modified glassy carbon electrode. CHEMOSPHERE 2022; 303:134961. [PMID: 35577133 DOI: 10.1016/j.chemosphere.2022.134961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/25/2022] [Accepted: 05/10/2022] [Indexed: 06/15/2023]
Abstract
Development of electrochemical sensors for important drugs such nicotine (an addictive drug) is important for the society. This study reports the electrochemical detection of nicotine at a carbon nanofiber/poly (amidoamine) dendrimer modified glassy carbon electrode. The carbon nanofiber (CNF) modified GCE was prepared by drop-coating followed by the electrodeposition of generation 4 poly (amidoamine) succinamic acid dendrimer (PAMAM) to form the sensor - CNF-PAMAM GCE. Characterization of prepared materials and modified electrodes was carried out using Fourier transmission infrared spectroscopy, field emission scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The CNF-PAMAM composite was confirmed by microscopy. A marked reduction in charge transfer resistance and increase in current of the CNF-PAMAM GCE in comparison to the bare electrode showed a synergic improvement electrochemical response because of the CNF-PAMAM nanocomposite. The CNF-PAMAM demonstrated an enhanced performance in the oxidation of nicotine in comparison to the bare GCE by shifting the anodic potential Epa of nicotine from 0.9 V to 0.8 V. The electrochemical sensor achieved a detection limit (LOD) of 0.02637 μM in the concentration range of 0.4815-15.41 μM of nicotine in 0.1 M PBS at pH 7.5. The sensor ability to determine nicotine in real samples was assessed in cigarettes obtaining recovery percentages of 88.00 and 97.42%. The sensor demonstrated selectivity toward nicotine in the presence of interferences. Finally, the method was validated by ultraviolet-visible spectroscopy analysis.
Collapse
Affiliation(s)
- Tsholofelo I Sebokolodi
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa
| | - Dimpo S Sipuka
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa
| | - Charles Muzenda
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa
| | - Oluchi V Nkwachukwu
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa
| | - Duduzile Nkosi
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa
| | - Omotayo A Arotiba
- Department of Chemical Sciences, University of Johannesburg, Doornfontein, 2028, South Africa; Centre for Nanomaterials Science Research, University of Johannesburg, South Africa.
| |
Collapse
|
16
|
Yence M, Cetinkaya A, Kaya SI, Ozkan SA. Recent Developments in the Sensitive Electrochemical Assay of Common Opioid Drugs. Crit Rev Anal Chem 2022; 54:882-895. [PMID: 35853096 DOI: 10.1080/10408347.2022.2099732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Opioids are a class of drugs used to treat moderate to severe pain and have short-term adverse effects. Nevertheless, they are considered necessary for pain management. However, well-known hazards are connected with an opioid prescription, such as overuse, addiction, and overdose deaths. For example, the death rate from opioid analgesic poisoning in the USA approximately doubled, owing to the overuse and addiction of opioid analgesics. Also, opioids are a very important group of analytes in forensic chemistry, so it is necessary to use reliable, fast, and sensitive analytical tools to determine opioid analgesics. This review focuses on the opioid overdose crisis, the properties of commonly used opioid drugs, their mechanism, effects, and some chromatographic and spectroscopic detection methods are explained briefly. Then most essentially recent developments covering the last ten years in the sensitive electrochemical methods of common opioid analgesics, their innovations and features, and future research directions are presented.
Collapse
Affiliation(s)
- Merve Yence
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
17
|
Boroujerdi R, Paul R. Graphene-Based Electrochemical Sensors for Psychoactive Drugs. NANOMATERIALS 2022; 12:nano12132250. [PMID: 35808086 PMCID: PMC9267978 DOI: 10.3390/nano12132250] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 06/24/2022] [Accepted: 06/26/2022] [Indexed: 12/11/2022]
Abstract
Sensors developed from nanomaterials are increasingly used in a variety of fields, from simple wearable or medical sensors to be used at home to monitor health, to more complicated sensors being used by border customs or aviation industries. In recent times, nanoparticle-based sensors have begun to revolutionize drug-detection techniques, mainly due to their affordability, ease of use and portability, compared to conventional chromatography techniques. Thin graphene layers provide a significantly high surface to weight ratio compared to other nanomaterials, a characteristic that has led to the design of more sensitive and reliable sensors. The exceptional properties of graphene coupled with its potential to be tuned to target specific molecules have made graphene-based sensors one of the most popular and well-researched sensing materials of the past two decades with applications in environmental monitoring, medical diagnostics, and industries. Here, we present a review of developments in the applications of graphene-based sensors in sensing drugs such as cocaine, morphine, methamphetamine, ketamine, tramadol and so forth in the past decade. We compare graphene sensors with other sensors developed from ultrathin two-dimensional materials, such as transition-metal dichalcogenides, hexagonal boron nitrate, and MXenes, to measure drugs directly and indirectly, in various samples.
Collapse
|
18
|
Baytak A, Aslanoglu M. Praseodymium doped dysprosium oxide‐carbon nanofibers based voltammetric platform for the simultaneous determination of sunset yellow and tartrazine. ELECTROANAL 2022. [DOI: 10.1002/elan.202200136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
19
|
Li Z, Shen F, Mishra RK, Wang Z, Zhao X, Zhu Z. Advances of Drugs Electroanalysis Based on Direct Electrochemical Redox on Electrodes: A Review. Crit Rev Anal Chem 2022; 54:269-314. [PMID: 35575782 DOI: 10.1080/10408347.2022.2072679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The strong development of mankind is inseparable from the proper use of drugs, and the electroanalytical research of drugs occupies an important position in the field of analytical chemistry. This review mainly elaborates the research progress of drugs electroanalysis based on direct electrochemical redox on various electrodes for the recent decade from 2011 to 2021. At first, we summarize some frequently used electrochemical data processing and electrochemical mechanism research derivation methods in the literature. Then, according to the drug therapeutic and application/usage purposes, the research progress of drugs electrochemical analysis is classified and discussed, where we focus on drugs electrochemical reaction mechanism. At the same time, the comparisons of electrochemical sensing performance of the drugs on various electrodes from recent studies are listed, so that readers can more intuitively compare and understand the electroanalytical sensing performance of each modified electrode for each of the drug. Finally, this review discusses the shortcomings and prospects of the drugs electroanalysis based on direct electrochemical redox research.
Collapse
Affiliation(s)
- Zhanhong Li
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Feichen Shen
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| | - Rupesh K Mishra
- Identify Sensors Biologics at Bindley Bioscience Center, West Lafayette, Indiana, USA
- School of Material Science and Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Zifeng Wang
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Xueling Zhao
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| | - Zhigang Zhu
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China
- School of Energy and Materials, Shanghai Polytechnic University, Shanghai, China
| |
Collapse
|
20
|
Kozak J, Tyszczuk-Rotko K, Sadok I, Sztanke K, Sztanke M. Application of a Screen-Printed Sensor Modified with Carbon Nanofibers for the Voltammetric Analysis of an Anticancer Disubstituted Fused Triazinone. Int J Mol Sci 2022; 23:2429. [PMID: 35269572 PMCID: PMC8910141 DOI: 10.3390/ijms23052429] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 02/18/2022] [Accepted: 02/18/2022] [Indexed: 01/01/2023] Open
Abstract
In this paper, we propose the first analytical procedure-using a screen-printed carbon electrode modified with carbon nanofibers (SPCE/CNFs)-for the detection and quantitative determination of an electroactive disubstituted fused triazinone, namely 4-Cl-PIMT, which is a promising anticancer drug candidate. The electrochemical performances of the sensor were investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square-wave adsorptive stripping voltammetry (SWAdSV). The presence of carbon nanofibers on the sensor surface caused a decrease in charge-transfer resistance and an increase in the active surface compared to the bare SPCE. Under the optimised experimental conditions, the proposed voltammetric procedure possesses a good linear response for the determination of 4-Cl-PIMT in the two linear ranges of 0.5-10 nM and 10-100 nM. The low limits of detection and quantification were calculated at 0.099 and 0.33 nM, respectively. In addition, the sensor displays high reproducibility and repeatability, as well as good selectivity. The selectivity was improved through the use of a flow system and a short accumulation time. The SWAdSV procedure with SPCE/CNFs was applied to determine 4-Cl-PIMT in human serum samples. The SWAdSV results were compared to those obtained by the ultra-high-performance liquid chromatography coupled with electrospray ionization/single-quadrupole mass spectrometry (UHPLC-ESI-MS) method.
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland; (J.K.); (K.T.-R.)
| | - Ilona Sadok
- Laboratory of Separation and Spectroscopic Method Applications, Centre for Interdisciplinary Research, Faculty of Science and Health, The John Paul II Catholic University of Lublin, 20-708 Lublin, Poland;
| | - Krzysztof Sztanke
- Laboratory of Bioorganic Synthesis and Analysis, Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland
| | - Małgorzata Sztanke
- Chair and Department of Medical Chemistry, Medical University of Lublin, 4A Chodźki Street, 20-093 Lublin, Poland;
| |
Collapse
|
21
|
Bongiovanni Abel S, Martinez MV, Bruno MM, Barbero CA, Abraham GA, Acevedo DF. A modular platform based on electrospun carbon nanofibers and poly(
N
‐isopropylacrylamide) hydrogel for sensor applications. POLYM ADVAN TECHNOL 2021. [DOI: 10.1002/pat.5473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Silvestre Bongiovanni Abel
- Research Institute of Materials Science and Technology (INTEMA) National University of Mar del Plata (UNMdP)‐National Council of Scientific and Technical Research (CONICET) Mar del Plata Argentina
| | - María V. Martinez
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Mariano M. Bruno
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Cesar A. Barbero
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| | - Gustavo A. Abraham
- Research Institute of Materials Science and Technology (INTEMA) National University of Mar del Plata (UNMdP)‐National Council of Scientific and Technical Research (CONICET) Mar del Plata Argentina
| | - Diego F. Acevedo
- Research Institute for Energy Technologies and Advanced Materials (IITEMA) National University of Río Cuarto (UNRC)‐National Council of Scientific and Technical Research (CONICET) Río Cuarto Argentina
| |
Collapse
|
22
|
Giyahban F, Amini S, Ebrahimzadeh H, Hejabri Kandeh S. Spin-column micro-solid phase extraction of phthalate esters using electrospun polyacrylonitrile/iron (III)/Mg-based metal-organic framework 88B followed by GC analysis. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106634] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
23
|
Development of a Dy 2O 3@Eu 2O 3-carbon nanofiber based electrode for highly sensitive detection of papaverine. Anal Chim Acta 2021; 1183:338972. [PMID: 34627531 DOI: 10.1016/j.aca.2021.338972] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/27/2021] [Accepted: 08/18/2021] [Indexed: 12/20/2022]
Abstract
A sensitive electrochemical method based on carbon nanofibers (CNFs) and bimetallic nanoparticles of dysprosium oxide (Dy2O3) and europium oxide (Eu2O3) was developed for the determination of papaverine in pharmaceuticals and human urine. Several electrodes were compared in respect to their electrochemically active surface area calculated as 0.0603, 0.1300, 0.3440, 0.3740 and 0.4990 cm2 for bare GCE, CNFs/GCE, Eu2O3-CNFs/GCE, Dy2O3-CNFs/GCE and Dy2O3@Eu2O3-CNFs/GCE, respectively. Electrodes were also compared in respect to their performance towards the voltammetric process of papaverine. The peak potential (Epa) of papaverine was 1.094 V, 0.993 V, 0.978 V, 0.969 V and 0.966 V at unmodified GCE, CNFs/GCE, Eu2O3-CNFs/GCE, Dy2O3-CNFs/GCE and Dy2O3@Eu2O3-CNFs/GCE, respectively. This indicated that the oxidation peak potential of papaverine shifted gradually towards the negative potentials and the peak current increased gradually from unmodified GCE to CNFs/GCE, Eu2O3-CNFs/GCE, Dy2O3-CNFs/GCE and Dy2O3@Eu2O3-CNFs/GCE. The influence of experimental parameters such as scan rate and pH on the voltammetry of papaverine was studied. The Dy2O3@Eu2O3-CNFs/GCE system presented a dynamic working range between 1.0 × 10-7 and 2.0 × 10-6 M with a detection limit of 1.0 × 10-8 M for papaverine. The platform (Dy2O3@Eu2O3-CNFs/GCE) exhibited excellent sensitivity and selectivity for papaverine in the presence of uric acid and was successfully applied for determining papaverine in pharmaceuticals and urine samples.
Collapse
|
24
|
Bourassi M, Pasichnyk M, Oesch O, Sundararajan S, Trávničková T, Soukup K, Kasher R, Gaálová J. Glycidyl and Methyl Methacrylate UV-Grafted PDMS Membrane Modification toward Tramadol Membrane Selectivity. MEMBRANES 2021; 11:752. [PMID: 34677519 PMCID: PMC8538421 DOI: 10.3390/membranes11100752] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 09/25/2021] [Accepted: 09/27/2021] [Indexed: 11/26/2022]
Abstract
Pharmaceutical wastewater pollution has reached an alarming stage, as many studies have reported. Membrane separation has shown great performance in wastewater treatment, but there are some drawbacks and undesired byproducts of this process. Selective membranes could be used for pollutant investigation sensors or even for pollutant recovery. The polydimethylsiloxane (PDMS) membrane was first tested on separated and mixed antibiotic (ATB) water solutions containing sulfamethoxazole (SM), trimethoprim (TMP), and tetracycline (TET). Then, the bare and ultra-violet grafted (UV-grafted) PDMS membranes (MMA-DMAEMA 10, GMA-DMAEMA 5, and GMA-DMAEMA 10) were tested in tramadol (TRA) separation, where the diffusion coefficient was evaluated. Finally, the membranes were tested in pertraction with a mixture of SM, TMP, TET, and TRA. The membranes were characterized using the following methods: contact angle measurement, FTIR, SEM/EDX, and surface and pore analysis. The main findings were that TET was co-eluted during mixed ATB pertraction, and GMA-DMAEMA 5 was found to selectively permeate TRA over the present ATBs.
Collapse
Affiliation(s)
- Mahdi Bourassi
- Faculty of Science Institute for Environmental Studies, Charles University, Benátská 2, 128 01 Prague, Czech Republic
- Institute of Chemical Process Fundamentals of the ASCR, v.v.i. Rozvojova 135, 165 00 Prague, Czech Republic; (M.P.); (T.T.); (K.S.); (J.G.)
- Institut de Chimie des Milieux et Matériaux de Poitiers, Poitiers University, 86073 Poitiers, France;
| | - Mariia Pasichnyk
- Institute of Chemical Process Fundamentals of the ASCR, v.v.i. Rozvojova 135, 165 00 Prague, Czech Republic; (M.P.); (T.T.); (K.S.); (J.G.)
| | - Oscar Oesch
- Institut de Chimie des Milieux et Matériaux de Poitiers, Poitiers University, 86073 Poitiers, France;
| | - Swati Sundararajan
- Department of Desalination & Water Treatment, Zuckerberg Institute for Water Research, Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Sede Boqer Campus, Midreshet Ben-Gurion 8499000, Israel; (S.S.); (R.K.)
| | - Tereza Trávničková
- Institute of Chemical Process Fundamentals of the ASCR, v.v.i. Rozvojova 135, 165 00 Prague, Czech Republic; (M.P.); (T.T.); (K.S.); (J.G.)
| | - Karel Soukup
- Institute of Chemical Process Fundamentals of the ASCR, v.v.i. Rozvojova 135, 165 00 Prague, Czech Republic; (M.P.); (T.T.); (K.S.); (J.G.)
| | - Roni Kasher
- Department of Desalination & Water Treatment, Zuckerberg Institute for Water Research, Jacob Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, Sede Boqer Campus, Midreshet Ben-Gurion 8499000, Israel; (S.S.); (R.K.)
| | - Jana Gaálová
- Institute of Chemical Process Fundamentals of the ASCR, v.v.i. Rozvojova 135, 165 00 Prague, Czech Republic; (M.P.); (T.T.); (K.S.); (J.G.)
| |
Collapse
|
25
|
Kozak J, Tyszczuk-Rotko K, Wójciak M, Sowa I. Electrochemically Activated Screen-Printed Carbon Sensor Modified with Anionic Surfactant (aSPCE/SDS) for Simultaneous Determination of Paracetamol, Diclofenac and Tramadol. MATERIALS 2021; 14:ma14133581. [PMID: 34206920 PMCID: PMC8269727 DOI: 10.3390/ma14133581] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 06/21/2021] [Accepted: 06/23/2021] [Indexed: 11/18/2022]
Abstract
In this work, an electrochemically activated screen-printed carbon electrode modified with sodium dodecyl sulfate (aSPCE/SDS) was proposed for the simultaneous determination of paracetamol (PA), diclofenac (DF), and tramadol (TR). Changes of surface morphology and electrochemical behaviour of the electrode after the electrochemical activation with H2O2 and SDS surface modification were studied by scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The influence of various parameters on the responses of the aSPCE/SDS such as pH and concentration of the buffer, SDS concentration, and techniques parameters were investigated. Using optimised conditions (Eacc. of −0.4 V, tacc. of 120 s, ΔEA of 150 mV, ν of 250 mV s−1, and tm of 10 ms), the aSPCE/SDS showed a good linear response in the concentration ranges of 5.0 × 10−8–2.0 × 10−5 for PA, 1.0 × 10−9–2.0 × 10−7 for DF, and 1.0 × 10−8–2.0 × 10−7 and 2.0 × 10−7–2.0 × 10−6 mol L−1 for TR. The limits of detection obtained during the simultaneous determination of PA, DF, and TR are 1.49 × 10−8 mol L−1, 2.10 × 10−10 mol L−1, and 1.71 × 10−9 mol L−1, respectively. The selectivity of the aSPCE/SDS was evaluated by examination of the impact of some inorganic and organic substances that are commonly present in environmental and biological samples on the responses of PA, DF, and TR. Finally, the differential pulse adsorptive stripping voltammetric (DPAdSV) procedure using the aSPCE/SDS was successfully applied for the determination of PA, DF, and TR in river water and serum samples as well as pharmaceuticals.
Collapse
Affiliation(s)
- Jędrzej Kozak
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University in Lublin, 20-031 Lublin, Poland;
- Correspondence: (K.T.-R.); (M.W.)
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
- Correspondence: (K.T.-R.); (M.W.)
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, 20-093 Lublin, Poland;
| |
Collapse
|
26
|
Halicka K, Cabaj J. Electrospun Nanofibers for Sensing and Biosensing Applications-A Review. Int J Mol Sci 2021; 22:6357. [PMID: 34198611 PMCID: PMC8232165 DOI: 10.3390/ijms22126357] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/11/2021] [Accepted: 06/11/2021] [Indexed: 12/19/2022] Open
Abstract
Sensors and biosensors have found applications in many areas, e.g., in medicine and clinical diagnostics, or in environmental monitoring. To expand this field, nanotechnology has been employed in the construction of sensing platforms. Because of their properties, such as high surface area to volume ratio, nanofibers (NFs) have been studied and used to develop sensors with higher loading capacity, better sensitivity, and faster response time. They also allow to miniaturize designed platforms. One of the most commonly used techniques of the fabrication of NFs is electrospinning. Electrospun NFs can be used in different types of sensors and biosensors. This review presents recent studies concerning electrospun nanofiber-based electrochemical and optical sensing platforms for the detection of various medically and environmentally relevant compounds, including glucose, drugs, microorganisms, and toxic metal ions.
Collapse
Affiliation(s)
| | - Joanna Cabaj
- Faculty of Chemistry, Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland;
| |
Collapse
|
27
|
Electrical Conductivity, Oil Absorption and Electric Heating of Carbon Black-modified Carbon Nanofibers. Chem Res Chin Univ 2021. [DOI: 10.1007/s40242-021-1109-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
28
|
Banitaba SN, Ehrmann A. Application of Electrospun Nanofibers for Fabrication of Versatile and Highly Efficient Electrochemical Devices: A Review. Polymers (Basel) 2021; 13:1741. [PMID: 34073391 PMCID: PMC8197972 DOI: 10.3390/polym13111741] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/23/2021] [Accepted: 05/24/2021] [Indexed: 02/06/2023] Open
Abstract
Electrochemical devices convert chemical reactions into electrical energy or, vice versa, electricity into a chemical reaction. While batteries, fuel cells, supercapacitors, solar cells, and sensors belong to the galvanic cells based on the first reaction, electrolytic cells are based on the reversed process and used to decompose chemical compounds by electrolysis. Especially fuel cells, using an electrochemical reaction of hydrogen with an oxidizing agent to produce electricity, and electrolytic cells, e.g., used to split water into hydrogen and oxygen, are of high interest in the ongoing search for production and storage of renewable energies. This review sheds light on recent developments in the area of electrospun electrochemical devices, new materials, techniques, and applications. Starting with a brief introduction into electrospinning, recent research dealing with electrolytic cells, batteries, fuel cells, supercapacitors, electrochemical solar cells, and electrochemical sensors is presented. The paper concentrates on the advantages of electrospun nanofiber mats for these applications which are mostly based on their high specific surface area and the possibility to tailor morphology and material properties during the spinning and post-treatment processes. It is shown that several research areas dealing with electrospun parts of electrochemical devices have already reached a broad state-of-the-art, while other research areas have large space for future investigations.
Collapse
Affiliation(s)
| | - Andrea Ehrmann
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences, 33619 Bielefeld, Germany
| |
Collapse
|
29
|
Afzali M, Mostafavi A, Afzali Z, Shamspur T. Designing a rapid and selective electrochemical nanosensor based on molecularly imprinted polymer on the Fe3O4/MoS2/glassy carbon electrode for detection of immunomodulatory drug pomalidomide. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
30
|
Li X, Xu T, Liang Z, Amar VS, Huang R, Maddipudi BK, Shende RV, Fong H. Simultaneous Electrospinning and Electrospraying for the Preparation of a Precursor Membrane Containing Hydrothermally Generated Biochar Particles to Produce the Value-Added Product of Carbon Nanofibrous Felt. Polymers (Basel) 2021; 13:676. [PMID: 33668134 PMCID: PMC7956330 DOI: 10.3390/polym13050676] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 02/21/2021] [Accepted: 02/21/2021] [Indexed: 11/17/2022] Open
Abstract
Biochar is a byproduct generated from the hydrothermal liquefaction of biomass, such as corn stover, in an anaerobic environment. This work aims to convert biochar into a value-added product of carbon nanofibrous felt. First, the biochar-containing precursor membrane was prepared from simultaneous electrospinning and electrospraying. After thermal stabilization in air and carbonization in argon, the obtained precursor membrane was converted into a mechanically flexible and robust carbon nanofibrous felt. Electrochemical results revealed that the biochar-derived carbon nanofibrous felt might be a good candidate as a supercapacitor electrode with a good rate capability and high kinetic performance.
Collapse
Affiliation(s)
- Xianfu Li
- Department of Chemistry and Applied Biological Sciences, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (X.L.); (T.X.); (Z.L.); (R.H.)
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu 241000, China
| | - Tao Xu
- Department of Chemistry and Applied Biological Sciences, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (X.L.); (T.X.); (Z.L.); (R.H.)
| | - Zhipeng Liang
- Department of Chemistry and Applied Biological Sciences, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (X.L.); (T.X.); (Z.L.); (R.H.)
| | - Vinod S. Amar
- Department of Chemical and Biological Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (V.S.A.); (B.K.M.)
| | - Runzhou Huang
- Department of Chemistry and Applied Biological Sciences, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (X.L.); (T.X.); (Z.L.); (R.H.)
| | - Bharath K. Maddipudi
- Department of Chemical and Biological Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (V.S.A.); (B.K.M.)
| | - Rajesh V. Shende
- Department of Chemical and Biological Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (V.S.A.); (B.K.M.)
| | - Hao Fong
- Department of Chemistry and Applied Biological Sciences, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA; (X.L.); (T.X.); (Z.L.); (R.H.)
| |
Collapse
|
31
|
Abdelshakour MA, Hadad GM, Abdel Salam RA, Abo-ElMatty DM, Abdel Hameed EA. HPLC and UPLC-MS/MS methods for analyzing TRAMADOL in 70 medicinal illegal products: Application to counterfeit study. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
32
|
Carbonaceous Nanomaterials Employed in the Development of Electrochemical Sensors Based on Screen-Printing Technique—A Review. Catalysts 2020. [DOI: 10.3390/catal10060680] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
This paper aims to revise research on carbonaceous nanomaterials used in developing sensors. In general, nanomaterials are known to be useful in developing high-performance sensors due to their unique physical and chemical properties. Thus, descriptions were made for various structural features, properties, and manner of functionalization of carbon-based nanomaterials used in electrochemical sensors. Of the commonly used technologies in manufacturing electrochemical sensors, the screen-printing technique was described, highlighting the advantages of this type of device. In addition, an analysis was performed in point of the various applications of carbon-based nanomaterial sensors to detect analytes of interest in different sample types.
Collapse
|