1
|
Vasantham S, Kotnala A, Promovych Y, Garstecki P, Derzsi L. Opto-hydrodynamic tweezers. LAB ON A CHIP 2024; 24:517-527. [PMID: 38165913 DOI: 10.1039/d3lc00733b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Optical fiber tweezers offer a simple, low-cost and portable solution for non-invasive trapping and manipulation of particles. However, single-fiber tweezers require fiber tip modification (tapering, lensing, etc.) and the dual-fiber approach demands strict alignment and positioning of fibers for robust trapping of particles. In addition, both tweezing techniques offer a limited range of particle manipulation and operate in low flow velocity regimes (a few 100 μm s-1) when integrated with microfluidic devices. In this paper, we report a novel opto-hydrodynamic fiber tweezers (OHT) platform that exploits the balance between the hydrodynamic drag force and optical scattering forces to trap and manipulate single or multiple particles of various shapes, sizes, and material compositions in a microfluidic channel. 3D hydrodynamic flow focusing offers an easy and dynamic alignment of the particle trajectories with the optical axis of the fiber, which enables robust trapping of particles with high efficiency of >70% and throughput of 14 particles per minute (operating flow velocity: 1000 μm s-1) without the need for precision stages or complex fabrication. By regulating the optical power and flow rates, we were able to trap single particles at desired positions in the channel with a precision of ±10 μm as well as manipulate them over a long range upstream or downstream with a maximum distance of 500 μm. Our opto-hydrodynamic tweezers offer an alternative to conventional optical fiber tweezers for several applications in physics, biology, medicine, etc.
Collapse
Affiliation(s)
- Shreyas Vasantham
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224, Warsaw, Poland.
| | - Abhay Kotnala
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224, Warsaw, Poland.
- Department of Electrical and Computer Engineering, University of Houston, Houston, Texas, 77204, USA
| | - Yurii Promovych
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224, Warsaw, Poland.
| | - Piotr Garstecki
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224, Warsaw, Poland.
| | - Ladislav Derzsi
- Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224, Warsaw, Poland.
| |
Collapse
|
2
|
Muhuri AK, Alapan Y, Camargo CP, Thomas SN. Microengineered In Vitro Assays for Screening and Sorting Manufactured Therapeutic T Cells. JOURNAL OF IMMUNOLOGY (BALTIMORE, MD. : 1950) 2024; 212:199-207. [PMID: 38166247 PMCID: PMC10783858 DOI: 10.4049/jimmunol.2300488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 11/10/2023] [Indexed: 01/04/2024]
Abstract
Adoptively transferred T cells constitute a major class of current and emergent cellular immunotherapies for the treatment of disease, including but not limited to cancer. Although key advancements in molecular recognition, genetic engineering, and manufacturing have dramatically enhanced their translational potential, therapeutic potency remains limited by poor homing and infiltration of transferred cells within target host tissues. In vitro microengineered homing assays with precise control over micromechanical and biological cues can address these shortcomings by enabling interrogation, screening, sorting, and optimization of therapeutic T cells based on their homing capacity. In this article, the working principles, application, and integration of microengineered homing assays for the mechanistic study of biophysical and biomolecular cues relevant to homing of therapeutic T cells are reviewed. The potential for these platforms to enable scalable enrichment and screening of next-generation manufactured T cell therapies for cancer is also discussed.
Collapse
Affiliation(s)
- Abir K. Muhuri
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology
| | - Yunus Alapan
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology
| | - Camila P. Camargo
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology
| | - Susan N. Thomas
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University
- Winship Cancer Institute, Emory University
| |
Collapse
|
3
|
Bayareh M. Active cell capturing for organ-on-a-chip systems: a review. BIOMED ENG-BIOMED TE 2022; 67:443-459. [PMID: 36062551 DOI: 10.1515/bmt-2022-0232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/25/2022] [Indexed: 11/15/2022]
Abstract
Organ-on-a-chip (OOC) is an emerging technology that has been proposed as a new powerful cell-based tool to imitate the pathophysiological environment of human organs. For most OOC systems, a pivotal step is to culture cells in microfluidic devices. In active cell capturing techniques, external actuators, such as electrokinetic, magnetic, acoustic, and optical forces, or a combination of these forces, can be applied to trap cells after ejecting cell suspension into the microchannel inlet. This review paper distinguishes the characteristics of biomaterials and evaluates microfluidic technology. Besides, various types of OOC and their fabrication techniques are reported and various active cell capture microstructures are analyzed. Furthermore, their constraints, challenges, and future perspectives are provided.
Collapse
Affiliation(s)
- Morteza Bayareh
- Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran
| |
Collapse
|
4
|
A Novel Mutual-Coupling Dipole Model Considering the Interactions between Particles. COATINGS 2022. [DOI: 10.3390/coatings12081079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The interactions between two or more particles and the calculation of the local electric field are widely applied in many fields, such as those of insulation, biology, medicine, and microfluidics. The dipole approximation model, which is a classical electric field calculation method, has been widely used in many fields to solve for the local electric field in a multi-particle system, but it does not consider the interactions between particles; as a result, it is easily limited by the calculation situation, and it generates a large calculation error when the distance between particles is small. Based on the physical essence of an interaction between two particles, a concept of the mutual-coupling dipole moment caused by the interactions between particles is defined for the first time. Moreover, by combining the calculation process of the dipole moment and the electric field of polarization, a novel mutual-coupling dipole model considering the interactions between particles is proposed in this paper, and analytical expressions of the local electric field that consider the interaction between two particles are obtained, thus compensating for the large error in the electric field calculation caused by the dipole approximation model when the distance between particles is small. In this paper, a mutual-coupling dipole model considering particle interactions is proposed. This model can effectively reflect the interactions between particles when the distance between particles D/R is less than 0.6 and accurately calculate the local electric fields of the particles. These results can be effectively used to investigate the interactions between particles and the control of particles in electric fields in many fields, such as in the calculation of the insulation of mixed dielectrics, the microscopic transport of medicines, the control of bio-cells and micro-fluids in electric fields, and environmental governance.
Collapse
|
5
|
Dellaquila A, Le Bao C, Letourneur D, Simon‐Yarza T. In Vitro Strategies to Vascularize 3D Physiologically Relevant Models. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2100798. [PMID: 34351702 PMCID: PMC8498873 DOI: 10.1002/advs.202100798] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/23/2021] [Indexed: 05/04/2023]
Abstract
Vascularization of 3D models represents a major challenge of tissue engineering and a key prerequisite for their clinical and industrial application. The use of prevascularized models built from dedicated materials could solve some of the actual limitations, such as suboptimal integration of the bioconstructs within the host tissue, and would provide more in vivo-like perfusable tissue and organ-specific platforms. In the last decade, the fabrication of vascularized physiologically relevant 3D constructs has been attempted by numerous tissue engineering strategies, which are classified here in microfluidic technology, 3D coculture models, namely, spheroids and organoids, and biofabrication. In this review, the recent advancements in prevascularization techniques and the increasing use of natural and synthetic materials to build physiological organ-specific models are discussed. Current drawbacks of each technology, future perspectives, and translation of vascularized tissue constructs toward clinics, pharmaceutical field, and industry are also presented. By combining complementary strategies, these models are envisioned to be successfully used for regenerative medicine and drug development in a near future.
Collapse
Affiliation(s)
- Alessandra Dellaquila
- Université de ParisINSERM U1148X Bichat HospitalParisF‐75018France
- Elvesys Microfluidics Innovation CenterParis75011France
- Biomolecular PhotonicsDepartment of PhysicsUniversity of BielefeldBielefeld33615Germany
| | - Chau Le Bao
- Université de ParisINSERM U1148X Bichat HospitalParisF‐75018France
- Université Sorbonne Paris NordGalilée InstituteVilletaneuseF‐93430France
| | | | | |
Collapse
|
6
|
Emerging Approaches to Understanding Microvascular Endothelial Heterogeneity: A Roadmap for Developing Anti-Inflammatory Therapeutics. Int J Mol Sci 2021; 22:ijms22157770. [PMID: 34360536 PMCID: PMC8346165 DOI: 10.3390/ijms22157770] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 07/12/2021] [Accepted: 07/16/2021] [Indexed: 12/14/2022] Open
Abstract
The endothelium is the inner layer of all blood vessels and it regulates hemostasis. It also plays an active role in the regulation of the systemic inflammatory response. Systemic inflammatory disease often results in alterations in vascular endothelium barrier function, increased permeability, excessive leukocyte trafficking, and reactive oxygen species production, leading to organ damage. Therapeutics targeting endothelium inflammation are urgently needed, but strong concerns regarding the level of phenotypic heterogeneity of microvascular endothelial cells between different organs and species have been expressed. Microvascular endothelial cell heterogeneity in different organs and organ-specific variations in endothelial cell structure and function are regulated by intrinsic signals that are differentially expressed across organs and species; a result of this is that neutrophil recruitment to discrete organs may be regulated differently. In this review, we will discuss the morphological and functional variations in differently originated microvascular endothelia and discuss how these variances affect systemic function in response to inflammation. We will review emerging in vivo and in vitro models and techniques, including microphysiological devices, proteomics, and RNA sequencing used to study the cellular and molecular heterogeneity of endothelia from different organs. A better understanding of microvascular endothelial cell heterogeneity will provide a roadmap for developing novel therapeutics to target the endothelium.
Collapse
|
7
|
Gharleghi R, Dessalles CA, Lal R, McCraith S, Sarathy K, Jepson N, Otton J, Barakat AI, Beier S. 3D Printing for Cardiovascular Applications: From End-to-End Processes to Emerging Developments. Ann Biomed Eng 2021; 49:1598-1618. [PMID: 34002286 PMCID: PMC8648709 DOI: 10.1007/s10439-021-02784-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 04/24/2021] [Indexed: 12/16/2022]
Abstract
3D printing as a means of fabrication has seen increasing applications in medicine in the last decade, becoming invaluable for cardiovascular applications. This rapidly developing technology has had a significant impact on cardiovascular research, its clinical translation and education. It has expanded our understanding of the cardiovascular system resulting in better devices, tools and consequently improved patient outcomes. This review discusses the latest developments and future directions of generating medical replicas ('phantoms') for use in the cardiovascular field, detailing the end-to-end process from medical imaging to capture structures of interest, to production and use of 3D printed models. We provide comparisons of available imaging modalities and overview of segmentation and post-processing techniques to process images for printing, detailed exploration of latest 3D printing methods and materials, and a comprehensive, up-to-date review of milestone applications and their impact within the cardiovascular domain across research, clinical use and education. We then provide an in-depth exploration of future technologies and innovations around these methods, capturing opportunities and emerging directions across increasingly realistic representations, bioprinting and tissue engineering, and complementary virtual and mixed reality solutions. The next generation of 3D printing techniques allow patient-specific models that are increasingly realistic, replicating properties, anatomy and function.
Collapse
Affiliation(s)
- Ramtin Gharleghi
- Faculty of Engineering, School of Mechanical and Manufacturing, UNSW, Sydney, Australia
| | | | - Ronil Lal
- Faculty of Engineering, School of Mechanical and Manufacturing, UNSW, Sydney, Australia
| | - Sinead McCraith
- Faculty of Engineering, School of Mechanical and Manufacturing, UNSW, Sydney, Australia
| | | | - Nigel Jepson
- Prince of Wales Hospital, Sydney, Australia
- Prince of Wales Clinical School of Medicine, UNSW, Sydney, Australia
| | - James Otton
- Department of Cardiology, Liverpool Hospital, Sydney, Australia
| | | | - Susann Beier
- Faculty of Engineering, School of Mechanical and Manufacturing, UNSW, Sydney, Australia.
| |
Collapse
|
8
|
Experimental Approaches to Evaluate Leukocyte-Endothelial Cell Interactions in Sepsis and Inflammation. Shock 2021; 53:585-595. [PMID: 32080065 DOI: 10.1097/shk.0000000000001407] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Sepsis is a life-threatening syndrome of organ dysfunction caused by a dysregulated host response to infection characterized by excessive neutrophil infiltration into vital organs. In sepsis, patients often die of organ failure and therapies directed against endothelial cell dysfunction and tissue damage are important targets for treatment of this disease. Novel approaches are required to understand the underlying pathophysiology of neutrophil dysregulation and neutrophil-endothelial cell interactions that play a critical role in the early course of organ damage and disruption of endothelial protective barrier. Here, we review methodologies that our laboratories have employed to study neutrophil-endothelial interaction and endothelial barrier function in in vivo and in vitro models of sepsis. We will focus on in vivo rodent models of sepsis and in vitro tools that use human cell culture models under static conditions and the more physiologically relevant biomimetic microfluidic assays. This Methods paper is based on our presentation in the Master Class Symposium at the 41st Annual Conference on Shock 2018.
Collapse
|
9
|
Oh HJ, Kim J, Kim H, Choi N, Chung S. Microfluidic Reconstitution of Tumor Microenvironment for Nanomedical Applications. Adv Healthc Mater 2021; 10:e2002122. [PMID: 33576178 DOI: 10.1002/adhm.202002122] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Indexed: 12/17/2022]
Abstract
Nanoparticles have an extensive range of diagnostic and therapeutic applications in cancer treatment. However, their current clinical translation is slow, mainly due to the failure to develop preclinical evaluation techniques that can draw similar conclusions to clinical outcomes by adequately mimicking nanoparticle behavior in complicated tumor microenvironments (TMEs). Microfluidic methods offer significant advantages over conventional in vitro methods to resolve these challenges by recapitulating physiological cues of the TME such as the extracellular matrix, shear stress, interstitial flow, soluble factors, oxygen, and nutrient gradients. The methods are capable of de-coupling microenvironmental features, spatiotemporal controlling of experimental sequences, and high throughput readouts in situ. This progress report highlights the recent achievements of microfluidic models to reconstitute the physiological microenvironment, especially for nanomedical tools for cancer treatment.
Collapse
Affiliation(s)
- Hyun Jeong Oh
- School of Mechanical Engineering Korea University Seoul 02841 Republic of Korea
| | - Jaehoon Kim
- School of Mechanical Engineering Korea University Seoul 02841 Republic of Korea
| | - Hyunho Kim
- School of Mechanical Engineering Korea University Seoul 02841 Republic of Korea
| | - Nakwon Choi
- Center for BioMicrosystems Brain Science Institute Korea Institute of Science and Technology (KIST) Seoul 02792 Republic of Korea
- Division of Bio‐Medical Science & Technology KIST School Korea University of Science and Technology (UST) Seoul 34113 Republic of Korea
- KU‐KIST Graduate School of Converging Science and Technology Korea University Seoul 02841 Republic of Korea
| | - Seok Chung
- School of Mechanical Engineering Korea University Seoul 02841 Republic of Korea
- KU‐KIST Graduate School of Converging Science and Technology Korea University Seoul 02841 Republic of Korea
| |
Collapse
|
10
|
Mechanisms of radiation-induced endothelium damage: Emerging models and technologies. Radiother Oncol 2021; 158:21-32. [PMID: 33581220 DOI: 10.1016/j.radonc.2021.02.007] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 02/04/2021] [Accepted: 02/05/2021] [Indexed: 12/24/2022]
Abstract
Radiation-induced endothelial/vascular injury is a major complicating factor in radiotherapy and a leading cause of morbidity and mortality in nuclear or radiological catastrophes. Exposure of tissue to ionizing radiation (IR) leads to the release of oxygen radicals and proteases that result in loss of endothelial barrier function and leukocyte dysfunction leading to tissue injury and organ damage. Microvascular endothelial cells are particularly sensitive to IR and radiation-induced alterations in endothelial cell function are thought to be a critical factor in organ damage through endothelial cell activation, enhanced leukocyte-endothelial cell interactions, increased barrier permeability and initiation of apoptotic pathways. These radiation-induced inflammatory responses are important in early and late radiation pathologies in various organs. A better understanding of mechanisms of radiation-induced endothelium dysfunction is therefore vital, as radiobiological response of endothelium is of major importance for medical management and therapeutic development for radiation injuries. In this review, we summarize the current knowledge of cellular and molecular mechanisms of radiation-induced endothelium damage and their impact on early and late radiation injury. Furthermore, we review established and emerging in vivo and in vitro models that have been developed to study the mechanisms of radiation-induced endothelium damage and to design, develop and rapidly screen therapeutics for treatment of radiation-induced vascular damage. Currently there are no specific therapeutics available to protect against radiation-induced loss of endothelial barrier function, leukocyte dysfunction and resulting organ damage. Developing therapeutics to prevent endothelium dysfunction and normal tissue damage during radiotherapy can serve as the urgently needed medical countermeasures.
Collapse
|
11
|
Yang Y, Geng J, Zhang H, Chen C, Li W, Qian Z, Li S. Image-guided simulation in comparison with laser speckle contrast imaging for full-field observation of blood flow in a microvasculature model. Microvasc Res 2021; 133:104092. [PMID: 33007315 DOI: 10.1016/j.mvr.2020.104092] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/21/2020] [Accepted: 09/25/2020] [Indexed: 11/19/2022]
Abstract
The in vitro reconstruction of the microvascular network model provides a reproducible platform for hemodynamic study with great biological relevance. In the present study, microvascular models with different parametric features were designed under the guidance of Murray's law and derived from representative natural vascular network topography in vivo. Computational fluid dynamics (CFD) was used to numerically simulate blood velocity distributions inside of the designed microvasculature models. Full-field blood flow in the vascular network was visualized in vivo using a laser speckle contrast imaging (LSCI) system, from which the measured relative velocity was compared with CFD computed flow distribution. The results have shown that, in comparison with the simplified flow patterns obtained from idealized geometries, the irregular vascular topography is expected to lead to nonuniform and poor regional blood velocity distribution. The velocity distribution acquired by in vivo LSCI experiment is in good agreement with that of numerical simulation, indicating the technical feasibility of using biomimetic microchannels as a reasonable approximation of the microcirculatory flow conditions. This study provides a new paradigm that can be well suited to the study of microvascular blood flow properties and can further expand to mimic other in-vivo scenarios for accurately recapitulating the physical and hemodynamic environment of the microcirculation.
Collapse
Affiliation(s)
- Yamin Yang
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.
| | - Jinfa Geng
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Huan Zhang
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Chunxiao Chen
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Weitao Li
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Zhiyu Qian
- Department of Biomedical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Siwen Li
- Department of Biomedical Engineering, China Pharmaceutical University, Nanjing 210009, China
| |
Collapse
|
12
|
Vu MN, Kelly HG, Wheatley AK, Peng S, Pilkington EH, Veldhuis NA, Davis TP, Kent SJ, Truong NP. Cellular Interactions of Liposomes and PISA Nanoparticles during Human Blood Flow in a Microvascular Network. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2002861. [PMID: 32583981 PMCID: PMC7361276 DOI: 10.1002/smll.202002861] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 06/04/2020] [Indexed: 05/21/2023]
Abstract
A key concept in nanomedicine is encapsulating therapeutic or diagnostic agents inside nanoparticles to prolong blood circulation time and to enhance interactions with targeted cells. During circulation and depending on the selected application (e.g., cancer drug delivery or immune modulators), nanoparticles are required to possess low or high interactions with cells in human blood and blood vessels to minimize side effects or maximize delivery efficiency. However, analysis of cellular interactions in blood vessels is challenging and is not yet realized due to the diverse components of human blood and hemodynamic flow in blood vessels. Here, the first comprehensive method to analyze cellular interactions of both synthetic and commercially available nanoparticles under human blood flow conditions in a microvascular network is developed. Importantly, this method allows to unravel the complex interplay of size, charge, and type of nanoparticles on their cellular associations under the dynamic flow of human blood. This method offers a unique platform to study complex interactions of any type of nanoparticles in human blood flow conditions and serves as a useful guideline for the rational design of liposomes and polymer nanoparticles for diverse applications in nanomedicine.
Collapse
Affiliation(s)
- Mai N. Vu
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
- Peter Doherty Institute for Infection and ImmunityDepartment of Microbiology and ImmunologyUniversity of MelbourneMelbourneVIC3000Australia
- Department of PharmaceuticsHanoi University of PharmacyHanoi10000Vietnam
| | - Hannah G. Kelly
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Peter Doherty Institute for Infection and ImmunityDepartment of Microbiology and ImmunologyUniversity of MelbourneMelbourneVIC3000Australia
| | - Adam K. Wheatley
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Peter Doherty Institute for Infection and ImmunityDepartment of Microbiology and ImmunologyUniversity of MelbourneMelbourneVIC3000Australia
| | - Scott Peng
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
| | - Emily H. Pilkington
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
- Peter Doherty Institute for Infection and ImmunityDepartment of Microbiology and ImmunologyUniversity of MelbourneMelbourneVIC3000Australia
| | - Nicholas A. Veldhuis
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
| | - Thomas P. Davis
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
- Australia Institute of Bioengineering & NanotechnologyUniversity of QueenslandBrisbaneQLD4072Australia
| | - Stephen J. Kent
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Peter Doherty Institute for Infection and ImmunityDepartment of Microbiology and ImmunologyUniversity of MelbourneMelbourneVIC3000Australia
- Melbourne Sexual Health Centre and Department of Infectious DiseasesAlfred Hospital and Central Clinical SchoolMonash UniversityMelbourneVIC3004Australia
| | - Nghia P. Truong
- Australian Research Council Centre of Excellence in Convergent Bio‐Nano Science and TechnologyParkvilleVIC3052Australia
- Monash Institute of Pharmaceutical SciencesMonash UniversityParkvilleVIC3052Australia
| |
Collapse
|
13
|
3D Sugar Printing of Networks Mimicking the Vasculature. MICROMACHINES 2019; 11:mi11010043. [PMID: 31905877 PMCID: PMC7019326 DOI: 10.3390/mi11010043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/20/2019] [Accepted: 12/27/2019] [Indexed: 12/16/2022]
Abstract
The vasculature plays a central role as the highway of the body, through which nutrients and oxygen as well as biochemical factors and signals are distributed by blood flow. Therefore, understanding the flow and distribution of particles inside the vasculature is valuable both in healthy and disease-associated networks. By creating models that mimic the microvasculature fundamental knowledge can be obtained about these parameters. However, microfabrication of such models remains a challenging goal. In this paper we demonstrate a promising 3D sugar printing method that is capable of recapitulating the vascular network geometry with a vessel diameter range of 1 mm down to 150 µm. For this work a dedicated 3D printing setup was built that is capable of accurately printing the sugar glass material with control over fibre diameter and shape. By casting of printed sugar glass networks in PDMS and dissolving the sugar glass, perfusable networks with circular cross-sectional channels are obtained. Using particle image velocimetry, analysis of the flow behaviour was conducted showing a Poisseuille flow profile inside the network and validating the quality of the printing process.
Collapse
|
14
|
Soroush F, Tang Y, Mustafa O, Sun S, Yang Q, Kilpatrick LE, Kiani MF. Neutrophil-endothelial interactions of murine cells is not a good predictor of their interactions in human cells. FASEB J 2019; 34:2691-2702. [PMID: 31908006 DOI: 10.1096/fj.201900048r] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 11/14/2019] [Accepted: 12/06/2019] [Indexed: 12/20/2022]
Abstract
All drugs recently developed in rodent models to treat inflammatory disease have failed in clinical trials. We therefore used our novel biomimetic microfluidic assay (bMFA) to determine whether the response of murine cells to inflammatory activation or anti-inflammatory treatment is predictive of the response in human cells. Under physiologically relevant flow conditions, permeability and transendothelial electrical resistance (TEER) of human or mouse lung microvascular endothelial cells (HLMVEC or MLMVEC), and neutrophil-endothelial cell interaction was measured. The differential impact of a protein kinase C-delta TAT peptide inhibitor (PKCδ-i) was also quantified. Permeability of HLMVEC and MLMVEC was similar under control conditions but tumor necrosis factor α (TNF-α) and PKCδ-i had a significantly higher impact on permeability of HLMVEC. TEER across HLMVEC was significantly higher than MLMVEC, but PKCδ-i returned TEER to background levels only in human cells. The kinetics of N-formylmethionyl-leucyl-phenylalanine (fMLP)-mediated neutrophil migration was significantly different between the two species and PKCδ-i was significantly more effective in attenuating human neutrophil migration. However, human and mouse neutrophil adhesion patterns to microvascular endothelium were not significantly different. Surprisingly, while intercellular adhesion molecule 1 (ICAM-1) was significantly upregulated on activated HLMVEC, it was not significantly upregulated on activated MLMVEC. Responses to activation and anti-inflammatory treatment in mice may not always be predictive of their response in humans.
Collapse
Affiliation(s)
- Fariborz Soroush
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, USA
| | - Yuan Tang
- Department of Bioengineering, College of Engineering, University of Toledo, Toledo, OH, USA
| | - Omar Mustafa
- Department of Bioengineering, College of Engineering, Temple University, Philadelphia, PA, USA
| | - Shuang Sun
- Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, USA
| | - Qingliang Yang
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, USA
| | - Laurie E Kilpatrick
- Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, USA
| | - Mohammad F Kiani
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, USA.,Department of Radiation Oncology, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, USA
| |
Collapse
|
15
|
Liu Z, Mackay S, Gordon DM, Anderson JD, Haithcock DW, Garson CJ, Tearney GJ, Solomon GM, Pant K, Prabhakarpandian B, Rowe SM, Guimbellot JS. Co-cultured microfluidic model of the airway optimized for microscopy and micro-optical coherence tomography imaging. BIOMEDICAL OPTICS EXPRESS 2019; 10:5414-5430. [PMID: 31646055 PMCID: PMC6788592 DOI: 10.1364/boe.10.005414] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 09/12/2019] [Accepted: 09/20/2019] [Indexed: 05/12/2023]
Abstract
We have developed a human bronchial epithelial (HBE) cell and endothelial cell co-cultured microfluidic model to mimic the in vivo human airway. This airway-on-a-chip was designed with a central epithelial channel and two flanking endothelial channels, with a three-dimensional monolayers of cells growing along the four walls of the channel, forming central clear lumens. These cultures mimic airways and microvasculature in vivo. The central channel cells are grown at air-liquid interface and show features of airway differentiation including tight-junction formation, mucus production, and ciliated cells. Combined with novel micro-optical coherence tomography, this chip enables functional imaging of the interior of the lumen, which includes quantitation of cilia motion including beat frequency and mucociliary transport. This airway-on-a chip is a significant step forward in the development of microfluidics models for functional imaging.
Collapse
Affiliation(s)
- Zhongyu Liu
- Department of Pediatrics, University of Alabama at Birmingham, Lowder Building Suite 620, 1600 7th Avenue South, Birmingham, AL 35233, USA
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
| | - Stephen Mackay
- Department of Pediatrics, University of Alabama at Birmingham, Lowder Building Suite 620, 1600 7th Avenue South, Birmingham, AL 35233, USA
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
| | - Dylan M. Gordon
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way NW, Huntsville, AL 35806, USA
| | - Justin D. Anderson
- Department of Pediatrics, University of Alabama at Birmingham, Lowder Building Suite 620, 1600 7th Avenue South, Birmingham, AL 35233, USA
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
| | - Dustin W. Haithcock
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way NW, Huntsville, AL 35806, USA
| | - Charles J. Garson
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way NW, Huntsville, AL 35806, USA
| | - Guillermo J. Tearney
- Department of Pathology, Wellman Center for Photomedicine, Massachusetts General Hospital, & Harvard Medical School, 55 Fruit St., Boston, MA 02114, USA
| | - George M. Solomon
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
- Department of Medicine, University of Alabama at Birmingham, THT 422, 1900 University Blvd, Birmingham, AL 35294, USA
| | - Kapil Pant
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way NW, Huntsville, AL 35806, USA
| | | | - Steven M. Rowe
- Department of Pediatrics, University of Alabama at Birmingham, Lowder Building Suite 620, 1600 7th Avenue South, Birmingham, AL 35233, USA
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
- Department of Medicine, University of Alabama at Birmingham, THT 422, 1900 University Blvd, Birmingham, AL 35294, USA
| | - Jennifer S. Guimbellot
- Department of Pediatrics, University of Alabama at Birmingham, Lowder Building Suite 620, 1600 7th Avenue South, Birmingham, AL 35233, USA
- Gregory Fleming James Cystic Fibrosis Research Center, University of Alabama at Birmingham, MCLM 706, 1918 University Blvd, Birmingham, AL 35294, USA
| |
Collapse
|
16
|
Miali ME, Colasuonno M, Surdo S, Palomba R, Pereira R, Rondanina E, Diaspro A, Pascazio G, Decuzzi P. Leaf-Inspired Authentically Complex Microvascular Networks for Deciphering Biological Transport Process. ACS APPLIED MATERIALS & INTERFACES 2019; 11:31627-31637. [PMID: 31412200 DOI: 10.1021/acsami.9b09453] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The vascular transport of molecules, cells, and nanoconstructs is a fundamental biophysical process impacting tissue regeneration, delivery of nutrients and therapeutic agents, and the response of the immune system to external pathogens. This process is often studied in single-channel microfluidic devices lacking the complex tridimensional organization of vascular networks. Here, soft lithography is employed to replicate the vein system of a Hedera elix leaf on a polydimethilsiloxane (PDMS) template. The replica is then sealed and connected to an external pumping system to realize an authentically complex microvascular network. This satisfies energy minimization criteria by Murray's law and comprises a network of channels ranging in size from capillaries (∼50 μm) to large arterioles and venules (∼400 μm). Micro-PIV (micro-particle image velocimetry) analysis is employed to characterize flow conditions in terms of streamlines, fluid velocity, and flow rates. To demonstrate the ability to reproduce physiologically relevant transport processes, two different applications are demonstrated: vascular deposition of tumor cells and lysis of blood clots. To this end, conditions are identified to culture cells within the microvasculature and realize a confluent endothelial monolayer. Then, the vascular deposition of circulating breast (MDA-MB 231) cancer cells is documented throughout the network under physiologically relevant flow conditions. Firm cell adhesion mostly occurs in channels with low mean blood velocity. As a second application, blood clots are formed within the chip by mixing whole blood with a thrombin solution. After demonstrating the blood clot stability, tissue plasminogen activator (tPA) and tPA-carrying nanoconstructs (tPA-DPNs) are employed as thrombolytics. In agreement with previous data, clot dissolution is equally induced by tPA and tPA-DPNs. The proposed leaf-inspired chip can be efficiently used to study a variety of vascular transport processes in complex microvascular networks, where geometry and flow conditions can be modulated and monitored throughout the experimental campaign.
Collapse
Affiliation(s)
- Marco E Miali
- Dipartimento di Meccanica, Matematica e Management, DMMM , Politecnico di Bari , Via Re David , 200-70125 Bari , Italy
- Laboratory of Nanotechnology for Precision Medicine , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Marianna Colasuonno
- Sant'Anna School of Advanced Studies , Piazza Martiri della Libertà 33 , 56127 Pisa , Italy
- Laboratory of Nanotechnology for Precision Medicine , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Salvatore Surdo
- Nanophysics Department , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Roberto Palomba
- Laboratory of Nanotechnology for Precision Medicine , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Rui Pereira
- Laboratory of Nanotechnology for Precision Medicine , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Eliana Rondanina
- Nanostructures , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Alberto Diaspro
- Nanophysics Department , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| | - Giuseppe Pascazio
- Dipartimento di Meccanica, Matematica e Management, DMMM , Politecnico di Bari , Via Re David , 200-70125 Bari , Italy
| | - Paolo Decuzzi
- Laboratory of Nanotechnology for Precision Medicine , Fondazione Istituto Italiano di Tecnologia , Via Morego 30 , 16163 Genoa , Italy
| |
Collapse
|
17
|
The Role of Tyrosine Phosphorylation of Protein Kinase C Delta in Infection and Inflammation. Int J Mol Sci 2019; 20:ijms20061498. [PMID: 30917487 PMCID: PMC6471617 DOI: 10.3390/ijms20061498] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 03/15/2019] [Accepted: 03/22/2019] [Indexed: 12/30/2022] Open
Abstract
Protein Kinase C (PKC) is a family composed of phospholipid-dependent serine/threonine kinases that are master regulators of inflammatory signaling. The activity of different PKCs is context-sensitive and these kinases can be positive or negative regulators of signaling pathways. The delta isoform (PKCδ) is a critical regulator of the inflammatory response in cancer, diabetes, ischemic heart disease, and neurodegenerative diseases. Recent studies implicate PKCδ as an important regulator of the inflammatory response in sepsis. PKCδ, unlike other members of the PKC family, is unique in its regulation by tyrosine phosphorylation, activation mechanisms, and multiple subcellular targets. Inhibition of PKCδ may offer a unique therapeutic approach in sepsis by targeting neutrophil-endothelial cell interactions. In this review, we will describe the overall structure and function of PKCs, with a focus on the specific phosphorylation sites of PKCδ that determine its critical role in cell signaling in inflammatory diseases such as sepsis. Current genetic and pharmacological tools, as well as in vivo models, that are used to examine the role of PKCδ in inflammation and sepsis are presented and the current state of emerging tools such as microfluidic assays in these studies is described.
Collapse
|
18
|
He Z, Ranganathan N, Li P. Evaluating nanomedicine with microfluidics. NANOTECHNOLOGY 2018; 29:492001. [PMID: 30215611 DOI: 10.1088/1361-6528/aae18a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Nanomedicines are engineered nanoscale structures that have an extensive range of application in the diagnosis and therapy of many diseases. Despite the rapid progress in and tremendous potential of nanomedicines, their clinical translational process is still slow, owing to the difficulty in understanding, evaluating, and predicting their behavior in complex living organisms. Microfluidic techniques offer a promising way to resolve these challenges. Carefully designed microfluidic chips enable in vivo microenvironment simulation and high-throughput analysis, thus providing robust platforms for nanomedicine evaluation. Here, we summarize the recent developments and achievements in microfluidic methods for nanomedicine evaluation, categorized into four sections based on their target systems: single cell, multicellular system, organ, and organism levels. Finally, we provide our perspectives on the challenges and future directions of microfluidics-based nanomedicine evaluation.
Collapse
Affiliation(s)
- Ziyi He
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, United States of America
| | | | | |
Collapse
|
19
|
Tang Y, Soroush F, Sun S, Liverani E, Langston JC, Yang Q, Kilpatrick LE, Kiani MF. Protein kinase C-delta inhibition protects blood-brain barrier from sepsis-induced vascular damage. J Neuroinflammation 2018; 15:309. [PMID: 30400800 PMCID: PMC6220469 DOI: 10.1186/s12974-018-1342-y] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 10/22/2018] [Indexed: 12/21/2022] Open
Abstract
Background Neuroinflammation often develops in sepsis leading to activation of cerebral endothelium, increased permeability of the blood-brain barrier (BBB), and neutrophil infiltration. We have identified protein kinase C-delta (PKCδ) as a critical regulator of the inflammatory response and demonstrated that pharmacologic inhibition of PKCδ by a peptide inhibitor (PKCδ-i) protected endothelial cells, decreased sepsis-mediated neutrophil influx into the lung, and prevented tissue damage. The objective of this study was to elucidate the regulation and relative contribution of PKCδ in the control of individual steps in neuroinflammation during sepsis. Methods The role of PKCδ in mediating human brain microvascular endothelial (HBMVEC) permeability, junctional protein expression, and leukocyte adhesion and migration was investigated in vitro using our novel BBB on-a-chip (B3C) microfluidic assay and in vivo in a rat model of sepsis induced by cecal ligation and puncture (CLP). HBMVEC were cultured under flow in the vascular channels of B3C. Confocal imaging and staining were used to confirm tight junction and lumen formation. Confluent HBMVEC were pretreated with TNF-α (10 U/ml) for 4 h in the absence or presence of PKCδ-i (5 μM) to quantify neutrophil adhesion and migration in the B3C. Permeability was measured using a 40-kDa fluorescent dextran in vitro and Evans blue dye in vivo. Results During sepsis, PKCδ is activated in the rat brain resulting in membrane translocation, a step that is attenuated by treatment with PKCδ-i. Similarly, TNF-α-mediated activation of PKCδ and its translocation in HBMVEC are attenuated by PKCδ-i in vitro. PKCδ inhibition significantly reduced TNF-α-mediated hyperpermeability and TEER decrease in vitro in activated HBMVEC and rat brain in vivo 24 h after CLP induced sepsis. TNF-α-treated HBMVEC showed interrupted tight junction expression, whereas continuous expression of tight junction protein was observed in non-treated or PKCδ-i-treated cells. PKCδ inhibition also reduced TNF-α-mediated neutrophil adhesion and migration across HBMVEC in B3C. Interestingly, while PKCδ inhibition decreased the number of adherent neutrophils to baseline (no-treatment group), it significantly reduced the number of migrated neutrophils below the baseline, suggesting a critical role of PKCδ in regulating neutrophil transmigration. Conclusions The BBB on-a-chip (B3C) in vitro assay is suitable for the study of BBB function as well as screening of novel therapeutics in real-time. PKCδ activation is a key signaling event that alters the structural and functional integrity of BBB leading to vascular damage and inflammation-induced tissue damage. PKCδ-TAT peptide inhibitor has therapeutic potential for the prevention or reduction of cerebrovascular injury in sepsis-induced vascular damage.
Collapse
Affiliation(s)
- Yuan Tang
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, 19122, USA
| | - Fariborz Soroush
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, 19122, USA
| | - Shuang Sun
- Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 19140, USA
| | - Elisabetta Liverani
- Sol Sherry Thrombosis Research Center, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 19140, USA
| | - Jordan C Langston
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, 19122, USA
| | - Qingliang Yang
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, 19122, USA
| | - Laurie E Kilpatrick
- Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 19140, USA
| | - Mohammad F Kiani
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, PA, 19122, USA. .,Department of Radiation Oncology, Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 19140, USA.
| |
Collapse
|
20
|
Lee S, Ko J, Park D, Lee SR, Chung M, Lee Y, Jeon NL. Microfluidic-based vascularized microphysiological systems. LAB ON A CHIP 2018; 18:2686-2709. [PMID: 30110034 DOI: 10.1039/c8lc00285a] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Microphysiological systems have emerged in the last decade to provide an alternative to in vivo models in basic science and pharmaceutical research. In the field of vascular biology, in particular, there has been a lack of a suitable in vitro model exhibiting a three-dimensional structure and the physiological function of vasculature integrated with organ-on-a-chip models. The rapid development of organ-on-a-chip technology is well positioned to fulfill unmet needs. Recently, functional integration of vasculature with diverse microphysiological systems has been increasing. This recent trend corresponds to emerging research interest in how the vascular system contributes to various physiological and pathological conditions. This innovative platform has undergone significant development, but adoption of this technology by end-users and researchers in biology is still a work in progress. Therefore, it is critical to focus on simplification and standardization to promote the distribution and acceptance of this technology by the end-users. In this review, we will introduce the latest developments in vascularized microphysiological systems and summarize their outlook in basic research and drug screening applications.
Collapse
Affiliation(s)
- Somin Lee
- Program for Bioengineering, Seoul National University, Seoul, 08826, Republic of Korea.
| | | | | | | | | | | | | |
Collapse
|
21
|
Khor SY, Vu MN, Pilkington EH, Johnston APR, Whittaker MR, Quinn JF, Truong NP, Davis TP. Elucidating the Influences of Size, Surface Chemistry, and Dynamic Flow on Cellular Association of Nanoparticles Made by Polymerization-Induced Self-Assembly. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1801702. [PMID: 30043521 DOI: 10.1002/smll.201801702] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Revised: 06/10/2018] [Indexed: 06/08/2023]
Abstract
The size and surface chemistry of nanoparticles dictate their interactions with biological systems. However, it remains unclear how these key physicochemical properties affect the cellular association of nanoparticles under dynamic flow conditions encountered in human vascular networks. Here, the facile synthesis of novel fluorescent nanoparticles with tunable sizes and surface chemistries and their association with primary human umbilical vein endothelial cells (HUVECs) is reported. First, a one-pot polymerization-induced self-assembly (PISA) methodology is developed to covalently incorporate a commercially available fluorescent dye into the nanoparticle core and tune nanoparticle size and surface chemistry. To characterize cellular association under flow, HUVECs are cultured onto the surface of a synthetic microvascular network embedded in a microfluidic device (SynVivo, INC). Interestingly, increasing the size of carboxylic acid-functionalized nanoparticles leads to higher cellular association under static conditions but lower cellular association under flow conditions, whereas increasing the size of tertiary amine-decorated nanoparticles results in a higher level of cellular association, under both static and flow conditions. These findings provide new insights into the interactions between polymeric nanomaterials and endothelial cells. Altogether, this work establishes innovative methods for the facile synthesis and biological characterization of polymeric nanomaterials for various potential applications.
Collapse
Affiliation(s)
- Song Yang Khor
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - Mai N Vu
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - Emily H Pilkington
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry, CV47AL, UK
| | - Angus P R Johnston
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - Michael R Whittaker
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - John F Quinn
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - Nghia P Truong
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
| | - Thomas P Davis
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC, 3052, Australia
- Department of Chemistry, University of Warwick, Gibbet Hill, Coventry, CV47AL, UK
| |
Collapse
|
22
|
Soroush F, Tang Y, Zaidi HM, Sheffield JB, Kilpatrick LE, Kiani MF. PKCδ inhibition as a novel medical countermeasure for radiation-induced vascular damage. FASEB J 2018; 32:fj201701099. [PMID: 29897816 DOI: 10.1096/fj.201701099] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
In the event of a radiologic catastrophe, endothelial cell and neutrophil dysfunction play important roles in tissue injury. Clinically available therapeutics for radiation-induced vascular injury are largely supportive. PKCδ was identified as a critical regulator of the inflammatory response, and its inhibition was shown to protect critical organs during sepsis. We used a novel biomimetic microfluidic assay (bMFA) to interrogate the role of PKCδ in radiation-induced neutrophil-endothelial cell interaction and endothelial cell function. HUVECs formed a complete lumen in bMFA and were treated with 0.5, 2, or 5 Gy ionizing radiation (IR). At 24 h post-IR, the cells were treated with a PKCδ inhibitor for an additional 24 h. Under physiologic shear flow, the role of PKCδ on endothelium function and neutrophil adherence/migration was determined. PKCδ inhibition dramatically attenuated IR-induced endothelium permeability increase and significantly decreased neutrophil migration across IR-treated endothelial cells. Moreover, neutrophil adhesion to irradiated endothelial cells was significantly decreased after PKCδ inhibition in a flow-dependent manner. PKCδ inhibition downregulated IR-induced P-selectin, intercellular adhesion molecule 1, and VCAM-1 but not E-selectin overexpression. PKCδ is an important regulator of neutrophil-endothelial cell interaction post-IR, and its inhibition can serve as a potential radiation medical countermeasure.-Soroush, F., Tang, Y., Zaidi, H. M., Sheffield, J. B., Kilpatrick, L. E., Kiani, M. F. PKCδ inhibition as a novel medical countermeasure for radiation-induced vascular damage.
Collapse
Affiliation(s)
- Fariborz Soroush
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | - Yuan Tang
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | - Hasan M Zaidi
- Department of Bioengineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | - Joel B Sheffield
- Department of Biology, Temple University, Philadelphia, Pennsylvania, USA
| | - Laurie E Kilpatrick
- Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania, USA
| | - Mohammad F Kiani
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
- Department of Radiation Oncology, Lewis Katz School of Medicine, Temple University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
23
|
Jarvis M, Arnold M, Ott J, Krishnan V, Pant K, Prabhakarpandian B, Mitragotri S. Detachment of ligands from nanoparticle surface under flow and endothelial cell contact: Assessment using microfluidic devices. Bioeng Transl Med 2018; 3:148-155. [PMID: 30065969 PMCID: PMC6063868 DOI: 10.1002/btm2.10089] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2017] [Revised: 03/16/2018] [Accepted: 03/21/2018] [Indexed: 01/09/2023] Open
Abstract
Surface modification of nanoparticles is a well‐established methodology to alter their properties to enhance circulation half‐life. While literature studies using conventional, in vitro characterization are routinely used to evaluate the biocompatibility of such modifications, relatively little attention has been paid to assess the stability of such surface modifications in physiologically relevant conditions. Here, microfluidic devices were used to study the effect of factors that adversely impact surface modifications including vascular flow and endothelial cell interactions. Camptothecin nanoparticles coated with polyethylene glycol (PEG) and/or folic acid were analyzed using linear channels and microvascular networks. Detachment of PEG was observed in cell‐free conditions and was attributed to interplay between the flow and method of PEG attachment. The flow and cells also impacted the surface charge of nanoparticles. Presence of endothelial cells further increased PEG shedding. The results demonstrate that endothelial cell contact, and vascular flow parameters modify surface ligands on nanoparticle surfaces.
Collapse
Affiliation(s)
- Maria Jarvis
- Biomolecular Sciences and Engineering Program University of California Santa Barbara CA 93106
| | - Michael Arnold
- Dept. of Molecular, Cellular and Developmental Biology University of California Santa Barbara CA 93106
| | - Jenna Ott
- Dept. of Chemical Engineering University of California Santa Barbara CA 93106
| | - Vinu Krishnan
- Dept. of Chemical Engineering University of California Santa Barbara CA 93106
| | - Kapil Pant
- Biomedical Technology, CFD Research Corporation Huntsville AL 35806
| | | | - Samir Mitragotri
- Dept. of Chemical Engineering University of California Santa Barbara CA 93106.,John A. Paulson School of Engineering and Applied Sciences Wyss Institute, Harvard University Cambridge MA 02138
| |
Collapse
|
24
|
Current developments and applications of microfluidic technology toward clinical translation of nanomedicines. Adv Drug Deliv Rev 2018; 128:54-83. [PMID: 28801093 DOI: 10.1016/j.addr.2017.08.003] [Citation(s) in RCA: 120] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2017] [Revised: 07/21/2017] [Accepted: 08/04/2017] [Indexed: 11/23/2022]
Abstract
Nanoparticulate drug delivery systems hold great potential for the therapy of many diseases, especially cancer. However, the translation of nanoparticulate drug delivery systems from academic research to industrial and clinical practice has been slow. This slow translation can be ascribed to the high batch-to-batch variations and insufficient production rate of the conventional preparation methods, and the lack of technologies for rapid screening of nanoparticulate drug delivery systems with high correlation to the in vivo tests. These issues can be addressed by the microfluidic technologies. For example, microfluidics can not only produce nanoparticles in a well-controlled, reproducible, and high-throughput manner, but also create 3D environments with continuous flow to mimic the physiological and/or pathological processes. This review provides an overview of the microfluidic devices developed to prepare nanoparticulate drug delivery systems, including drug nanosuspensions, polymer nanoparticles, polyplexes, structured nanoparticles and theranostic nanoparticles. We also highlight the recent advances of microfluidic systems in fabricating the increasingly realistic models of the in vivo milieu for rapid screening of nanoparticles. Overall, the microfluidic technologies offer a promise approach to accelerate the clinical translation of nanoparticulate drug delivery systems.
Collapse
|
25
|
Tsai HF, Trubelja A, Shen AQ, Bao G. Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment. J R Soc Interface 2018. [PMID: 28637915 DOI: 10.1098/rsif.2017.0137] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Cancer remains one of the leading causes of death, albeit enormous efforts to cure the disease. To overcome the major challenges in cancer therapy, we need to have a better understanding of the tumour microenvironment (TME), as well as a more effective means to screen anti-cancer drug leads; both can be achieved using advanced technologies, including the emerging tumour-on-a-chip technology. Here, we review the recent development of the tumour-on-a-chip technology, which integrates microfluidics, microfabrication, tissue engineering and biomaterials research, and offers new opportunities for building and applying functional three-dimensional in vitro human tumour models for oncology research, immunotherapy studies and drug screening. In particular, tumour-on-a-chip microdevices allow well-controlled microscopic studies of the interaction among tumour cells, immune cells and cells in the TME, of which simple tissue cultures and animal models are not amenable to do. The challenges in developing the next-generation tumour-on-a-chip technology are also discussed.
Collapse
Affiliation(s)
- Hsieh-Fu Tsai
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa 904-0495, Japan
| | - Alen Trubelja
- Department of Bioengineering, Rice University, Houston, TX 77030, USA
| | - Amy Q Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa 904-0495, Japan
| | - Gang Bao
- Department of Bioengineering, Rice University, Houston, TX 77030, USA
| |
Collapse
|
26
|
Yan S, Li Y, Zhao Q, Yuan D, Yun G, Zhang J, Wen W, Tang SY, Li W. Liquid metal-based amalgamation-assisted lithography for fabrication of complex channels with diverse structures and configurations. LAB ON A CHIP 2018; 18:785-792. [PMID: 29424381 DOI: 10.1039/c8lc00047f] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Numerous lab-on-a-chip applications benefit from channels with complex structures and configurations in the areas of tissue engineering and clinical diagnostics. The current fabrication approaches require time-consuming, complicated processes and bulky, expensive facilities. In this work, we propose a novel method for the fabrication of complex channels with the assistance of amalgamation of liquid metal with copper tape. This new technique enables the rapid fabrication of liquid metal molds with various dimensions and diverse structures. Two proof-of-concept experiments were conducted to verify the utilization of this method. First, the channel replicated from the liquid metal mold is used to enhance the mixing performance of liquids flowing through the channel. Second, a channel with a semicircular cross-section is fabricated to achieve 3D focusing in a simple way. This proposed technique can be readily used for fabricating complex channels for a wide range of applications.
Collapse
Affiliation(s)
- Sheng Yan
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Hwang Y, Candler RN. Non-planar PDMS microfluidic channels and actuators: a review. LAB ON A CHIP 2017; 17:3948-3959. [PMID: 28862708 DOI: 10.1039/c7lc00523g] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
This review examines the state of the art for manufacturing non-planar miniature channels and actuators from PDMS, where non-planar structures are defined here as those beyond simple extrusions of 2D designs, either with rounded or variable cross sections or with an emergence of the channel trajectory out-of-plane. The motivation for 3D PDMS structures and advances in their fabrication are described, focusing on geometries that were previously unachievable through conventional microfabrication. The motivation for non-planar microfluidic channels and actuators is first discussed and the existing literature is grouped into general fabrication themes and described. The structures are organized by their method of fabrication and evaluated based on their relevant properties, including the capability of producing structures with complex geometry, automation of the fabrication process, and minimum feature size. Additional properties are included for work in the more recently emerging field of non-planar PDMS actuators, where the feature size, actuation stroke, and actuation method are the key parameters of interest. In particular, this review considers the impact from recent advances in additive manufacturing, which now allow creation of truly arbitrary 3D structures down to ∼100 μm size scales.
Collapse
Affiliation(s)
- Yongha Hwang
- Department of Electro-Mechanical Systems Engineering, Korea University Sejong Campus, South Korea.
| | | |
Collapse
|
28
|
Blaha L, Zhang C, Cabodi M, Wong JY. A microfluidic platform for modeling metastatic cancer cell matrix invasion. Biofabrication 2017; 9:045001. [PMID: 28812983 DOI: 10.1088/1758-5090/aa869d] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Invasion of the extracellular matrix is a critical step in the colonization of metastatic tumors. The invasion process is thought to be driven by both chemokine signaling and interactions between invading cancer cells and physical components of the metastatic niche, including endothelial cells that line capillary walls and serve as a barrier to both diffusion and invasion of the underlying tissue. Transwell chambers, a tool for generating artificial chemokine gradients to induce cell migration, have facilitated recent work to investigate the chemokine contributions to matrix invasion. These chambers, however, are poorly designed for imaging, which limits their use in investigating the physical cell-cell and cell-matrix interactions driving matrix invasion. Microfluidic devices offer a promising model in which the invasion process can be imaged. Many current designs, however, have limited surface areas and possess intricate geometries that preclude the use of standard staining protocols to visualize cells and matrix proteins. In this work, we present a novel microfluidic platform for imaging cell-cell and cell-matrix interactions driving metastatic cancer cell matrix invasion. Our model is applied to investigate how endothelial cell-secreted matrix proteins and the physical endothelial monolayer itself interact with invading metastatic breast cancer cells to facilitate invasion of an underlying type I collagen gel. The results show that matrix invasion of metastatic breast cancer cells is significantly enhanced in the presence of live endothelial cells. Probing this interaction further, our platform revealed that, while the fibronectin-rich matrix deposited by endothelial cells was not sufficient to drive invasion alone, metastatic breast cancer cells were able to exploit components of energetically inactivated endothelial cells to gain entry into the underlying matrix. These findings reveal novel cell-cell interactions driving a key step in the colonization of metastatic tumors and have important implications for designing drugs targeted at preventing cancer metastasis.
Collapse
Affiliation(s)
- Laura Blaha
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, United States of America
| | | | | | | |
Collapse
|
29
|
A Biomimetic Microfluidic Tumor Microenvironment Platform Mimicking the EPR Effect for Rapid Screening of Drug Delivery Systems. Sci Rep 2017; 7:9359. [PMID: 28839211 PMCID: PMC5571192 DOI: 10.1038/s41598-017-09815-9] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 07/31/2017] [Indexed: 01/18/2023] Open
Abstract
Real-time monitoring of tumor drug delivery in vivo is a daunting challenge due to the heterogeneity and complexity of the tumor microenvironment. In this study, we developed a biomimetic microfluidic tumor microenvironment (bMTM) comprising co-culture of tumor and endothelial cells in a 3D environment. The platform consists of a vascular compartment featuring a network of vessels cultured with endothelial cells forming a complete lumen under shear flow in communication with 3D solid tumors cultured in a tumor compartment. Endothelial cell permeability to both small dye molecules and large liposomal drug carriers were quantified using fluorescence microscopy. Endothelial cell intercellular junction formation was characterized by immunostaining. Endothelial cell permeability significantly increased in the presence of either tumor cell conditioned media (TCM) or tumor cells. The magnitude of this increase in permeability was significantly higher in the presence of metastatic breast tumor cells as compared to non-metastatic ones. Immunostaining revealed impaired endothelial cell-cell junctions in the presence of either metastatic TCM or metastatic tumor cells. Our findings indicate that the bMTM platform mimics the tumor microenvironment including the EPR effect. This platform has a significant potential in applications such as cell-cell/cell-drug carrier interaction studies and rapid screening of cancer drug therapeutics/carriers.
Collapse
|
30
|
Brazilek RJ, Tovar-Lopez FJ, Wong AKT, Tran H, Davis AS, McFadyen JD, Kaplan Z, Chunilal S, Jackson SP, Nandurkar H, Mitchell A, Nesbitt WS. Application of a strain rate gradient microfluidic device to von Willebrand's disease screening. LAB ON A CHIP 2017; 17:2595-2608. [PMID: 28660968 DOI: 10.1039/c7lc00498b] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Von Willebrand's disease (VWD) is the most common inherited bleeding disorder caused by either quantitative or qualitative defects of von Willebrand factor (VWF). Current tests for VWD require relatively large blood volumes, have low throughput, are time-consuming, and do not incorporate the physiologically relevant effects of haemodynamic forces. We developed a microfluidic device incorporating micro-contractions that harnesses well-defined haemodynamic strain gradients to initiate platelet aggregation in citrated whole blood. The microchannel architecture has been specifically designed to allow for continuous real-time imaging of platelet aggregation dynamics. Subjects aged ≥18 years with previously diagnosed VWD or who presented for evaluation of a bleeding disorder, where the possible diagnosis included VWD, were tested. Samples were obtained for device characterization as well as for pathology-based testing. Platelet aggregation in the microfluidic device is independent of platelet amplification loops but dependent on low-level platelet activation, GPIb/IX/V and integrin αIIbβ3 engagement. Microfluidic output directly correlates with VWF antigen levels and is able to sensitively detect aggregation defects associated with VWD subtypes. Testing demonstrated a strong correlation with standard clinical laboratory-based tests. Head-to-head comparison with PFA100® demonstrated equivalent, if not improved, sensitivity for screening aggregation defects associated with VWD. This strain rate gradient microfluidic prototype has the potential to be a clinically useful, rapid and high throughput-screening tool for VWD as well as other strain-dependent platelet disorders. In addition, the microfluidic device represents a novel approach to examine the effects of high magnitude/short duration (ms) strain rate gradients on platelet function.
Collapse
Affiliation(s)
- Rose J Brazilek
- The Australian Centre for Blood Diseases, Monash University, Alfred Medical Research and Educational Precinct, Melbourne, Victoria, Australia
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
To curb the high cost of drug development, there is an urgent need to develop more predictive tissue models using human cells to determine drug efficacy and safety in advance of clinical testing. Recent insights gained through fundamental biological studies have validated the importance of dynamic cell environments and cellular communication to the expression of high fidelity organ function. Building on this knowledge, emerging organ-on-a-chip technology is poised to fill the gaps in drug screening by offering predictive human tissue models with methods of sophisticated tissue assembly. Organ-on-a-chip start-ups have begun to spawn from academic research to fill this commercial space and are attracting investment to transform the drug discovery industry. This review traces the history, examines the scientific foundation and envisages the prospect of these renowned organ-on-a-chip technologies. It serves as a guide for new members of this dynamic field to navigate the existing scientific and market space.
Collapse
Affiliation(s)
- Boyang Zhang
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON, Canada.
| | | |
Collapse
|
32
|
Zilberman-Rudenko J, Sylman JL, Garland KS, Puy C, Wong AD, Searson PC, McCarty OJT. Utility of microfluidic devices to study the platelet-endothelium interface. Platelets 2017; 28:449-456. [PMID: 28358586 DOI: 10.1080/09537104.2017.1280600] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The integration of biomaterials and understanding of vascular biology has led to the development of perfusable endothelialized flow models, which have been used as valuable tools to study the platelet-endothelium interface under shear. In these models, the parameters of geometry, compliance, biorheology, and cellular complexity are varied to recapitulate the physical biology of platelet recruitment and activation under physiologically relevant conditions of blood flow. In this review, we summarize the mechanistic insights learned from perfusable microvessel models and discuss the potential utility as well as challenges of endothelialized microfluidic devices to study platelet function in the bloodstream in vitro.
Collapse
Affiliation(s)
- Jevgenia Zilberman-Rudenko
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Joanna L Sylman
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Kathleen S Garland
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA.,c Division of Pediatric Hematology/Oncology , Oregon Health and Science University , Portland , OR , USA
| | - Cristina Puy
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Andrew D Wong
- b Institute for Nanobiotechnology (INBT) , Johns Hopkins University , Baltimore , MD , USA.,d Department of Materials Science and Engineering , Johns Hopkins University , Baltimore , MD , USA
| | - Peter C Searson
- b Institute for Nanobiotechnology (INBT) , Johns Hopkins University , Baltimore , MD , USA.,d Department of Materials Science and Engineering , Johns Hopkins University , Baltimore , MD , USA
| | - Owen J T McCarty
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA.,c Division of Pediatric Hematology/Oncology , Oregon Health and Science University , Portland , OR , USA
| |
Collapse
|
33
|
Soroush F, Zhang T, King DJ, Tang Y, Deosarkar S, Prabhakarpandian B, Kilpatrick LE, Kiani MF. A novel microfluidic assay reveals a key role for protein kinase C δ in regulating human neutrophil-endothelium interaction. J Leukoc Biol 2016; 100:1027-1035. [PMID: 27190303 DOI: 10.1189/jlb.3ma0216-087r] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 04/26/2016] [Indexed: 12/13/2022] Open
Abstract
A key step in neutrophil-mediated tissue damage is the migration of activated neutrophils across the vascular endothelium. Previously, we identified protein kinase C δ as a critical regulator of neutrophil migration in sepsis but did not identify specific steps in migration. In this study, we used our novel biomimetic microfluidic assay to delineate systematically the mechanism by which protein kinase C δ regulates individual steps in human neutrophil-endothelial interaction during inflammation. The biomimetic microfluidic assay includes a network of vascular channels, produced from in vivo images connected to a tissue compartment through a porous barrier. HUVECs cultured in vascular channels formed a complete lumen under physiologic shear flow. HUVECs were pretreated with TNF-α ± a protein kinase C δ inhibitor, and the tissue compartment was filled with a chemoattractant (fMLP or IL-8). Under physiologic shear flow, the role of protein kinase C δ on spatial and temporal neutrophil adherence/migration was quantified. Protein kinase C δ inhibition significantly reduced neutrophil adhesion in response to fMLP and IL-8 only under low shear rate and near bifurcations. Protein kinase C δ inhibition also decreased adherence to nonactivated HUVECs in response to fMLP or IL-8. Protein kinase C δ inhibition reduced neutrophil migration into the tissue compartment in response to fMLP and to a lesser degree, to IL-8. Antibody-coated microparticles demonstrated that protein kinase C δ inhibition down-regulated E-selectin and ICAM-1 but not VCAM-1 expression. With the use of a physiologically relevant in vitro model system, we demonstrate that protein kinase C δ plays an important role in the regulation of neutrophil adherence/migration during inflammation and identifies key steps regulated by protein kinase C δ in neutrophil-endothelial interactions.
Collapse
Affiliation(s)
- Fariborz Soroush
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | - Ting Zhang
- Department of Physiology and Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine at Temple University, Philadelphia, Pennsylvania, USA
| | - Devon J King
- Department of Physiology and Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine at Temple University, Philadelphia, Pennsylvania, USA
| | - Yuan Tang
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | - Sudhir Deosarkar
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA
| | | | - Laurie E Kilpatrick
- Department of Physiology and Center for Inflammation, Clinical and Translational Lung Research, Lewis Katz School of Medicine at Temple University, Philadelphia, Pennsylvania, USA
| | - Mohammad F Kiani
- Department of Mechanical Engineering, College of Engineering, Temple University, Philadelphia, Pennsylvania, USA; .,Shriners Hospitals Pediatric Research Center, Temple University School of Medicine, Philadelphia, Pennsylvania, USA
| |
Collapse
|
34
|
Integrative Utilization of Microenvironments, Biomaterials and Computational Techniques for Advanced Tissue Engineering. J Biotechnol 2015; 212:71-89. [DOI: 10.1016/j.jbiotec.2015.08.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2015] [Revised: 08/02/2015] [Accepted: 08/11/2015] [Indexed: 01/13/2023]
|
35
|
Abstract
Platelet transfusions total >2.17 million apheresis-equivalent units per year in the United States and are derived entirely from human donors, despite clinically significant immunogenicity, associated risk of sepsis, and inventory shortages due to high demand and 5-day shelf life. To take advantage of known physiological drivers of thrombopoiesis, we have developed a microfluidic human platelet bioreactor that recapitulates bone marrow stiffness, extracellular matrix composition,micro-channel size, hemodynamic vascular shear stress, and endothelial cell contacts, and it supports high-resolution live-cell microscopy and quantification of platelet production. Physiological shear stresses triggered proplatelet initiation, reproduced ex vivo bone marrow proplatelet production, and generated functional platelets. Modeling human bone marrow composition and hemodynamics in vitro obviates risks associated with platelet procurement and storage to help meet growing transfusion needs.
Collapse
|
36
|
Panneerselvam K, Lynge ME, Riber CF, Mena-Hernando S, Smith AAA, Goldie KN, Zelikin AN, Städler B. Phospholipid-polymer amphiphile hybrid assemblies and their interaction with macrophages. BIOMICROFLUIDICS 2015; 9:052610. [PMID: 26339330 PMCID: PMC4552693 DOI: 10.1063/1.4929405] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Accepted: 08/11/2015] [Indexed: 05/06/2023]
Abstract
Recently, the combination of lipids and block copolymers has become an alternative to liposomes and polymersomes as nano-sized drug carriers. We synthesize novel block copolymers consisting of poly(cholesteryl acrylate) as the hydrophobic core and poly(N-isopropylacrylamide) (PNIPAAm) as the hydrophilic extensions. Their successful phospholipid-assisted assembly into vesicles is demonstrated using the evaporation-hydration method. The preserved thermo-responsive property of the lipid-polymer hybrids is shown by a temperature dependent adsorption behaviour of the vesicles to poly(l lysine) coated surfaces. As expected, the vesicle adsorption is found to be higher at elevated temperatures. The cellular uptake efficiency of hybrids is assessed using macrophages with applied shear stress. The amount of adhering macrophages is affected by the time and level of applied shear stress. Further, it is found that shorter PNIPAAm extensions lead to higher uptake of the assemblies by the macrophages with applied shear stress. No inherent cytotoxicity is observed at the tested conditions. Taken together, this first example of responsive lipid-polymer hybrids, and their positive biological evaluation makes them promising nano-sized drug carrier candidates.
Collapse
Affiliation(s)
| | - Martin E Lynge
- Aarhus University , Interdisciplinary Nanoscience Center (iNANO), Aarhus, Denmark
| | | | - Sofia Mena-Hernando
- Aarhus University , Interdisciplinary Nanoscience Center (iNANO), Aarhus, Denmark
| | - Anton A A Smith
- Department of Chemistry, Aarhus University , Aarhus, Denmark
| | - Kenneth N Goldie
- Center for Cellular Imaging and Nano Analytics, Biozentrum, University of Basel , Basel, Switzerland
| | | | - Brigitte Städler
- Aarhus University , Interdisciplinary Nanoscience Center (iNANO), Aarhus, Denmark
| |
Collapse
|
37
|
Combariza ME, Yu X, Nesbitt WS, Mitchell A, Tovar-Lopez FJ. Nonlinear Dynamic Modelling of Platelet Aggregation via Microfluidic Devices. IEEE Trans Biomed Eng 2015; 62:1718-27. [DOI: 10.1109/tbme.2015.2403266] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
38
|
Abstract
One of the cardinal processes of inflammation is the infiltration of immune cells from the lumen of the blood vessel to the surrounding tissue. This occurs when endothelial cells, which line blood vessels, become adhesive to circulating immune cells such as monocytes. In vitro measurement of this adhesiveness has until now been done by quantifying the total number of monocytes that adhere to an endothelial layer either as a direct count or by indirect measurement of the fluorescence of adherent monocytes. While such measurements do indicate the average adhesiveness of the endothelial cell population, they are confounded by a number of factors, such as cell number, and do not reveal the proportion of endothelial cells that are actually adhesive. Here we describe and demonstrate a method which allows the enumeration of adhesive cells within a tested population of endothelial monolayer. Endothelial cells are grown on glass coverslips and following desired treatment are challenged with monocytes (that may be fluorescently labeled). After incubation, a rinsing procedure, involving multiple rounds of immersion and draining, the cells are fixed. Adhesive endothelial cells, which are surrounded by monocytes are readily identified and enumerated, giving an adhesion index that reveals the actual proportion of endothelial cells within the population that are adhesive.
Collapse
Affiliation(s)
- Donna J Lowe
- Biological Effects Department, Centre for Radiation, Chemicals and Environmental Hazards, Public Health England
| | - Kenneth Raj
- Biological Effects Department, Centre for Radiation, Chemicals and Environmental Hazards, Public Health England;
| |
Collapse
|
39
|
Harris DG, Benipal PK, Cheng X, Burdorf L, Azimzadeh AM, Pierson RN. Four-dimensional characterization of thrombosis in a live-cell, shear-flow assay: development and application to xenotransplantation. PLoS One 2015; 10:e0123015. [PMID: 25830912 PMCID: PMC4382176 DOI: 10.1371/journal.pone.0123015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Accepted: 02/26/2015] [Indexed: 02/01/2023] Open
Abstract
Background Porcine xenografts are a promising source of scarce transplantable organs, but stimulate intense thrombosis of human blood despite targeted genetic and pharmacologic interventions. Current experimental models do not enable study of the blood/endothelial interface to investigate adhesive interactions and thrombosis at the cellular level under physiologic conditions. The purpose of this study was to develop and validate a live-cell, shear-flow based thrombosis assay relevant to general thrombosis research, and demonstrate its potential in xenotransplantation applications. Methodology/Principal Findings Confluent wild-type (WT, n = 48) and Gal transferase knock-out (GalTKO, which resist hyperacute rejection; n = 11) porcine endothelia were cultured in microfluidic channels. To mimic microcirculatory flow, channels were perfused at 5 dynes/cm2 and 37°C with human blood stained to fluorescently label platelets. Serial fluorescent imaging visualized percent surface area coverage (SA, for adhesion of labeled cells) and total fluorescence (a metric of clot volume). Aggregation was calculated by the fluorescence/SA ratio (FR). WT endothelia stimulated diffuse platelet adhesion (SA 65 ± 2%) and aggregation (FR 120 ± 1 a.u.), indicating high-grade thrombosis consistent with the rapid platelet activation and consumption seen in whole-organ lung xenotransplantation models. Experiments with antibody blockade of platelet aggregation, and perfusion of syngeneic and allo-incompatible endothelium was used to verify the biologic specificity and validity of the assay. Finally, with GalTKO endothelia thrombus volume decreased by 60%, due primarily to a 58% reduction in adhesion (P < 0.0001 each); importantly, aggregation was only marginally affected (11% reduction, P < 0.0001). Conclusions/Significance This novel, high-throughput assay enabled dynamic modeling of whole-blood thrombosis on intact endothelium under physiologic conditions, and allowed mechanistic characterization of endothelial and platelet interactions. Applied to xenogeneic thrombosis, it enables future studies regarding the effect of modifying the porcine genotype on sheer-stress-dependent events that characterize xenograft injury. This in-vitro platform is likely to prove broadly useful to study thrombosis and endothelial interactions under dynamic physiologic conditions.
Collapse
Affiliation(s)
- Donald G Harris
- Division of General Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America; Center for Vascular and Inflammatory Diseases, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| | - Prabhjot K Benipal
- Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| | - Xiangfei Cheng
- Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| | - Lars Burdorf
- Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| | - Agnes M Azimzadeh
- Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America
| | - Richard N Pierson
- Division of Cardiac Surgery, Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, United States of America; Surgical Care Clinical Center, VA Maryland Health Care System, Baltimore, Maryland, United States of America
| |
Collapse
|
40
|
Kawano Y, Otsuka C, Sanzo J, Higgins C, Nirei T, Schilling T, Ishikawa T. Expanding imaging capabilities for microfluidics: applicability of darkfield internal reflection illumination (DIRI) to observations in microfluidics. PLoS One 2015; 10:e0116925. [PMID: 25748425 PMCID: PMC4352060 DOI: 10.1371/journal.pone.0116925] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2014] [Accepted: 12/16/2014] [Indexed: 01/09/2023] Open
Abstract
Microfluidics is used increasingly for engineering and biomedical applications due to recent advances in microfabrication technologies. Visualization of bubbles, tracer particles, and cells in a microfluidic device is important for designing a device and analyzing results. However, with conventional methods, it is difficult to observe the channel geometry and such particles simultaneously. To overcome this limitation, we developed a Darkfield Internal Reflection Illumination (DIRI) system that improved the drawbacks of a conventional darkfield illuminator. This study was performed to investigate its utility in the field of microfluidics. The results showed that the developed system could clearly visualize both microbubbles and the channel wall by utilizing brightfield and DIRI illumination simultaneously. The methodology is useful not only for static phenomena, such as clogging, but also for dynamic phenomena, such as the detection of bubbles flowing in a channel. The system was also applied to simultaneous fluorescence and DIRI imaging. Fluorescent tracer beads and channel walls were observed clearly, which may be an advantage for future microparticle image velocimetry (μPIV) analysis, especially near a wall. Two types of cell stained with different colors, and the channel wall, can be recognized using the combined confocal and DIRI system. Whole-slide imaging was also conducted successfully using this system. The tiling function significantly expands the observing area of microfluidics. The developed system will be useful for a wide variety of engineering and biomedical applications for the growing field of microfluidics.
Collapse
Affiliation(s)
- Yoshihiro Kawano
- The Department of Biomedical Engineering, Graduate School of Biomedical Engineering, Tohoku University, Sendai, Miyagi, Japan; Olympus Corporation, Shinjuku-Ku, Tokyo, Japan
| | | | - James Sanzo
- Olympus Scientific Solutions Americas, Waltham, Massachusetts, United States of America
| | - Christopher Higgins
- Olympus Scientific Solutions Americas, Waltham, Massachusetts, United States of America
| | | | | | - Takuji Ishikawa
- Department of Bioengineering and Robotics, Tohoku University, Sendai, Miyagi, Japan
| |
Collapse
|
41
|
Lamberti G, Soroush F, Smith A, Kiani MF, Prabhakarpandian B, Pant K. Adhesion patterns in the microvasculature are dependent on bifurcation angle. Microvasc Res 2015; 99:19-25. [PMID: 25708050 DOI: 10.1016/j.mvr.2015.02.004] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 01/14/2015] [Accepted: 02/11/2015] [Indexed: 01/16/2023]
Abstract
Particle adhesion in vivo is highly dependent on the microvascular environment comprising of unique anatomical, geometrical, physiological fluid flow conditions and cell-particle and cell-cell interactions. Hence, proper design of vascular-targeted drug carriers that efficiently deliver therapeutics to the targeted cells or tissue at effective concentrations must account for these complex conditions observed in vivo. In this study, we build upon our previous results with the goal of characterizing the effects of bifurcations and their corresponding angle on adhesion of functionalized particles and neutrophils to activated endothelium. Our hypothesis is that adhesion is significantly affected by the type of biochemical interactions between particles and vessel wall as well as the presence of bifurcations and their corresponding angle. Here, we investigate adhesion of functionalized particles (2 μm and 7 μm microparticles) to protein coated channels as well as adhesion of human neutrophils to human endothelial cells under various physiological flow conditions in microfluidic bifurcating channels comprising of different contained angles (30°, 60°, 90°, or 120°). Our findings indicate that both functionalized particle and neutrophil adhesion propensity increase with a larger bifurcation angle. Moreover, the difference in the adhesion patterns of neutrophils and rigid, similar sized (7 μm) particles is more apparent in the junction regions with a larger contained angle. By selecting the right particle size range, enhanced targeted binding of vascular drug carriers can be achieved along with a higher efficacy at optimal drug dosage. Hence, vascular drug particle design needs to be tailored to account for higher binding propensity at larger bifurcation angles.
Collapse
Affiliation(s)
- Giuseppina Lamberti
- Department of Mechanical Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, USA
| | - Fariborz Soroush
- Department of Mechanical Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, USA
| | - Ashley Smith
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way, Huntsville, AL 35806, USA
| | - Mohammad F Kiani
- Department of Mechanical Engineering, Temple University, 1947 N. 12th Street, Philadelphia, PA 19122, USA; Department of Radiation Oncology, Temple University School of Medicine, 3500 N. Broad Street, Philadelphia, PA 19140, USA
| | | | - Kapil Pant
- Biomedical Technology, CFD Research Corporation, 701 McMillian Way, Huntsville, AL 35806, USA
| |
Collapse
|
42
|
Skommer J, Wlodkowic D. Successes and future outlook for microfluidics-based cardiovascular drug discovery. Expert Opin Drug Discov 2015; 10:231-44. [PMID: 25672221 DOI: 10.1517/17460441.2015.1001736] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
INTRODUCTION The greatest advantage of using microfluidics as a platform for the assessment of cardiovascular drug action is its ability to finely regulate fluid flow conditions, including flow rate, shear stress and pulsatile flow. At the same time, microfluidics provide means for modifying the vessel geometry (bifurcations, stenoses, complex networks), the type of surface of the vessel walls, and for patterning cells in 3D tissue-like architecture, including generation of lumen walls lined with cells and heart-on-a-chip structures for mimicking ventricular cardiomyocyte physiology. In addition, owing to the small volume of required specimens, microfluidics is ideally suited to clinical situations whereby monitoring of drug dosing or efficacy needs to be coupled with minimal phlebotomy-related drug loss. AREAS COVERED In this review, the authors highlight potential applications for the currently existing and emerging technologies and offer several suggestions on how to close the development cycle of microfluidic devices for cardiovascular drug discovery. EXPERT OPINION The ultimate goal in microfluidics research for drug discovery is to develop 'human-on-a-chip' systems, whereby several organ cultures, including the vasculature and the heart, can mimic complex interactions between the organs and body systems. This would provide in vivo-like pharmacokinetics and pharmacodynamics for drug ADMET assessment. At present, however, the great variety of available designs does not go hand in hand with their use by the pharmaceutical community.
Collapse
Affiliation(s)
- Joanna Skommer
- RMIT University, School of Applied Sciences , Melbourne, VIC , Australia
| | | |
Collapse
|
43
|
An in silico analysis of nanoparticle/cell diffusive transfer: application to nano-artificial antigen-presenting cell:T-cell interaction. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2015; 11:1019-28. [PMID: 25652896 DOI: 10.1016/j.nano.2014.12.019] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 12/07/2014] [Accepted: 12/29/2014] [Indexed: 02/04/2023]
Abstract
UNLABELLED Polymeric nanoparticles (nano-paAPCs) modified with T-cell antigens and encapsulating immunostimulatory or immunoinhibitory factors may act as artificial antigen-presenting cells to circulating immune cells, improving the selective delivery of encapsulated drug or cytokine to antigen-specific T-cells. Paracrine delivery of encapsulated agents from these nanoparticles to adjacent cells facilitate sustained delivery lowering the overall administered dose, thus enhancing the overall drug efficacy while reducing toxicity of pleiotropic factors. Little is known mathematically regarding the local concentration of released agent that accumulates around a nanoparticle that is near or embeds in a cell. These concentration fields are calculated here in an attempt to understand paracrine efficacy of these nano-paAPC systems. The significant factor accumulation that can occur if the particles were to embed in the cell membrane may explain observed experimental data regarding enhanced T-cell activation and nanoparticle-mediated improvement in the drug delivery process to non-internalizing cellular targets. FROM THE CLINICAL EDITOR In this interesting article, the authors utilized nanosized polymeric artificial presenting cells (nano-paAPC) that released cytokine to study the effects after interaction with T cells. It was found that nano-paAPC were able to embed into cell membrane, with subsequent enhanced T-cell activation. The findings provide further understanding of immune cell interaction and are considered to be important for designing nanoparticles engineered to deliver cytokines or immumodulatory factors to specific immune cells.
Collapse
|
44
|
Synthetic tumor networks for screening drug delivery systems. J Control Release 2015; 201:49-55. [PMID: 25599856 DOI: 10.1016/j.jconrel.2015.01.018] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Revised: 12/06/2014] [Accepted: 01/16/2015] [Indexed: 01/24/2023]
Abstract
Tumor drug delivery is a complex phenomenon affected by several elements in addition to drug or delivery vehicle's physico-chemical properties. A key factor is tumor microvasculature with complex effects including convective transport, high interstitial pressure and enhanced vascular permeability due to the presence of "leaky vessels". Current in vitro models of the tumor microenvironment for evaluating drug delivery are oversimplified and, as a result, show poor correlation with in vivo performance. In this study, we report on the development of a novel microfluidic platform that models the tumor microenvironment more accurately, with physiologically and morphologically realistic microvasculature including endothelial cell lined leaky capillary vessels along with 3D solid tumors. Endothelial cells and 3D spheroids of cervical tumor cells were co-cultured in the networks. Drug vehicle screening was demonstrated using GFP gene delivery by different formulations of nanopolymers. The synthetic tumor network was successful in predicting in vivo delivery efficiencies of the drug vehicles. The developed assay will have critical applications both in basic research, where it can be used to develop next generation delivery vehicles, and in drug discovery where it can be used to study drug transport and delivery efficacy in realistic tumor microenvironment, thereby enabling drug compound and/or delivery vehicle screening.
Collapse
|
45
|
Jenkins MJ, Farid SS. Human pluripotent stem cell-derived products: advances towards robust, scalable and cost-effective manufacturing strategies. Biotechnol J 2014; 10:83-95. [PMID: 25524780 PMCID: PMC4674985 DOI: 10.1002/biot.201400348] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Revised: 09/18/2014] [Accepted: 10/13/2014] [Indexed: 02/06/2023]
Abstract
The ability to develop cost-effective, scalable and robust bioprocesses for human pluripotent stem cells (hPSCs) will be key to their commercial success as cell therapies and tools for use in drug screening and disease modelling studies. This review outlines key process economic drivers for hPSCs and progress made on improving the economic and operational feasibility of hPSC bioprocesses. Factors influencing key cost metrics, namely capital investment and cost of goods, for hPSCs are discussed. Step efficiencies particularly for differentiation, media requirements and technology choice are amongst the key process economic drivers identified for hPSCs. Progress made to address these cost drivers in hPSC bioprocessing strategies is discussed. These include improving expansion and differentiation yields in planar and bioreactor technologies, the development of xeno-free media and microcarrier coatings, identification of optimal bioprocess operating conditions to control cell fate and the development of directed differentiation protocols that reduce reliance on expensive morphogens such as growth factors and small molecules. These approaches offer methods to further optimise hPSC bioprocessing in terms of its commercial feasibility.
Collapse
Affiliation(s)
- Michael J Jenkins
- Department of Biochemical Engineering, University College London, London, UK
| | | |
Collapse
|
46
|
Björnmalm M, Yan Y, Caruso F. Engineering and evaluating drug delivery particles in microfluidic devices. J Control Release 2014; 190:139-49. [DOI: 10.1016/j.jconrel.2014.04.030] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Revised: 03/14/2014] [Accepted: 03/21/2014] [Indexed: 02/03/2023]
|
47
|
Lamberti G, Prabhakarpandian B, Garson C, Smith A, Pant K, Wang B, Kiani MF. Bioinspired microfluidic assay for in vitro modeling of leukocyte-endothelium interactions. Anal Chem 2014; 86:8344-51. [PMID: 25135319 PMCID: PMC4139165 DOI: 10.1021/ac5018716] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Accepted: 07/28/2014] [Indexed: 01/08/2023]
Abstract
Current in vitro models of the leukocyte adhesion cascade cannot be used for real-time studies of the entire leukocyte adhesion cascade, including rolling, adhesion, and migration in a single assay. In this study, we have developed and validated a novel bioinspired microfluidic assay (bMFA) and used it to test the hypothesis that blocking of specific steps in the adhesion/migration cascade significantly affects other steps of the cascade. The bMFA consists of an endothelialized microvascular network in communication with a tissue compartment via a 3 μm porous barrier. Human neutrophils in bMFA preferentially adhered to activated human endothelial cells near bifurcations with rolling and adhesion patterns in close agreement with in vivo observations. Treating endothelial cells with monoclonal antibodies to E-selectin or ICAM-1 or treating neutrophils with wortmannin reduced rolling, adhesion, and migration of neutrophils to 60%, 20%, and 18% of their respective control values. Antibody blocking of specific steps in the adhesion/migration cascade (e.g., mAb to E-selectin) significantly downregulated other steps of the cascade (e.g., migration). This novel in vitro assay provides a realistic human cell based model for basic science studies, identification of new treatment targets, selection of pathways to target validation, and rapid screening of candidate agents.
Collapse
Affiliation(s)
- Giuseppina Lamberti
- Department
of Mechanical Engineering, Temple University, 1947 N. 12th street, Philadelphia, Pennsylvania 19122, United States
| | | | - Charles Garson
- Biomedical
Technology, CFD Research Corporation, 701 McMillian Way, Huntsville, Alabama 35806, United
States
| | - Ashley Smith
- Biomedical
Technology, CFD Research Corporation, 701 McMillian Way, Huntsville, Alabama 35806, United
States
| | - Kapil Pant
- Biomedical
Technology, CFD Research Corporation, 701 McMillian Way, Huntsville, Alabama 35806, United
States
| | - Bin Wang
- Department
of Mechanical Engineering, Temple University, 1947 N. 12th street, Philadelphia, Pennsylvania 19122, United States
- Department
of Biomedical Engineering, Widener University, One University Place, Chester, Pennsylvania 19013-5792, United States
| | - Mohammad F. Kiani
- Department
of Mechanical Engineering, Temple University, 1947 N. 12th street, Philadelphia, Pennsylvania 19122, United States
- Department
of Radiation Oncology, Temple University
School of Medicine, 3500
N. Broad Street, Philadelphia, Pennsylvania 19140, United States
| |
Collapse
|
48
|
Polini A, Prodanov L, Bhise NS, Manoharan V, Dokmeci MR, Khademhosseini A. Organs-on-a-chip: a new tool for drug discovery. Expert Opin Drug Discov 2014; 9:335-52. [PMID: 24620821 DOI: 10.1517/17460441.2014.886562] [Citation(s) in RCA: 143] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
INTRODUCTION The development of emerging in vitro tissue culture platforms can be useful for predicting human response to new compounds, which has been traditionally challenging in the field of drug discovery. Recently, several in vitro tissue-like microsystems, also known as 'organs-on-a-chip', have emerged to provide new tools for better evaluating the effects of various chemicals on human tissue. AREAS COVERED The aim of this article is to provide an overview of the organs-on-a-chip systems that have been recently developed. First, the authors introduce single-organ platforms, focusing on the most studied organs such as liver, heart, blood vessels and lung. Later, the authors briefly describe tumor-on-a-chip platforms and highlight their application for testing anti-cancer drugs. Finally, the article reports a few examples of other organs integrated in microfluidic chips along with preliminary multiple-organs-on-a-chip examples. The article also highlights key fabrication points as well as the main application areas of these devices. EXPERT OPINION This field is still at an early stage and major challenges need to be addressed prior to the embracement of these technologies by the pharmaceutical industry. To produce predictive drug screening platforms, several organs have to be integrated into a single microfluidic system representative of a humanoid. The routine production of metabolic biomarkers of the organ constructs, as well as their physical environment, have to be monitored prior to and during the delivery of compounds of interest to be able to translate the findings into useful discoveries.
Collapse
Affiliation(s)
- Alessandro Polini
- Brigham and Women's Hospital, Harvard Medical School, Division of Biomedical Engineering, Department of Medicine , Cambridge, MA 02139 , USA
| | | | | | | | | | | |
Collapse
|
49
|
Tokárová V, Pittermannová A, Král V, Řezáčová P, Štěpánek F. Feasibility and constraints of particle targeting using the antigen-antibody interaction. NANOSCALE 2013; 5:11490-11498. [PMID: 24170264 PMCID: PMC4047836 DOI: 10.1039/c3nr04340a] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Accepted: 10/03/2013] [Indexed: 06/02/2023]
Abstract
This work is concerned with the surface modification of fluorescent silica nanoparticles by a monoclonal antibody (M75) and the specific bioadhesion of such particles to surfaces containing the PG domain of carbonic anhydrase IX (CA IX), which is a trans-membrane protein specifically expressed on the surfaces of several tumor cell lines. The adhesion strength of antibody-bearing silica nanoparticles to antigen-bearing surfaces was investigated under laminar flow conditions in a microfluidic cell and compared to the adhesion of unmodified silica nanoparticles and nanoparticles coupled with an unspecific antibody. Adhesion to cancer cells using flow cytometry was also investigated and in all cases the adhesion strength of M75-modified nanoparticles was significantly stronger than for the unmodified or unspecific nanoparticles, up to several orders of magnitude in some cases. The specific modification of nano- and microparticles by an antibody-like protein therefore appears to be a feasible approach for the targeting of tumor cells.
Collapse
Affiliation(s)
- Viola Tokárová
- Institute of Chemical Technology Prague , Department of Chemical Engineering , Technická 3 , Prague 6 , 166 28 , Czech Republic . ; Tel: +420 220 443 236
| | - Anna Pittermannová
- Institute of Chemical Technology Prague , Department of Chemical Engineering , Technická 3 , Prague 6 , 166 28 , Czech Republic . ; Tel: +420 220 443 236
| | - Vlastimil Král
- Laboratory of Structural Biology , Institute of Molecular Genetics , Academy of Sciences of the Czech Republic , v.v.i., Vídeňská 1083 , Praha 4 , 142 20 , Czech Republic
| | - Pavlína Řezáčová
- Laboratory of Structural Biology , Institute of Molecular Genetics , Academy of Sciences of the Czech Republic , v.v.i., Vídeňská 1083 , Praha 4 , 142 20 , Czech Republic
| | - František Štěpánek
- Institute of Chemical Technology Prague , Department of Chemical Engineering , Technická 3 , Prague 6 , 166 28 , Czech Republic . ; Tel: +420 220 443 236
| |
Collapse
|
50
|
Banerjee P, Kintzios S, Prabhakarpandian B. Biotoxin detection using cell-based sensors. Toxins (Basel) 2013; 5:2366-83. [PMID: 24335754 PMCID: PMC3873691 DOI: 10.3390/toxins5122366] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Revised: 11/22/2013] [Accepted: 11/25/2013] [Indexed: 12/11/2022] Open
Abstract
Cell-based biosensors (CBBs) utilize the principles of cell-based assays (CBAs) by employing living cells for detection of different analytes from environment, food, clinical, or other sources. For toxin detection, CBBs are emerging as unique alternatives to other analytical methods. The main advantage of using CBBs for probing biotoxins and toxic agents is that CBBs respond to the toxic exposures in the manner related to actual physiologic responses of the vulnerable subjects. The results obtained from CBBs are based on the toxin-cell interactions, and therefore, reveal functional information (such as mode of action, toxic potency, bioavailability, target tissue or organ, etc.) about the toxin. CBBs incorporate both prokaryotic (bacteria) and eukaryotic (yeast, invertebrate and vertebrate) cells. To create CBB devices, living cells are directly integrated onto the biosensor platform. The sensors report the cellular responses upon exposures to toxins and the resulting cellular signals are transduced by secondary transducers generating optical or electrical signals outputs followed by appropriate read-outs. Examples of the layout and operation of cellular biosensors for detection of selected biotoxins are summarized.
Collapse
Affiliation(s)
- Pratik Banerjee
- Division of Epidemiology, Biostatistics, and Environmental Health, School of Public Health, The University of Memphis, 338 Robison Hall, 3825 Desoto Avenue, Memphis, TN 38152, USA
| | - Spyridon Kintzios
- School of Food Science, Biotechnology and Development, Faculty of Biotechnology, Agricultural University of Athens, Iera Odos 75, Athens 11855, Greece; E-Mail:
| | - Balabhaskar Prabhakarpandian
- Bioengineering Laboratory Core, Cellular and Biomolecular Engineering, CFD Research Corporation, 701 McMillian Way NW, Huntsville, AL 35806, USA; E-Mail:
| |
Collapse
|