1
|
Koizumi J, Ohya T. Effects of High-Intensity Inspiratory Muscle Warm-Up on High-Intensity Exercise Performance and Muscle Oxygenation. Int J Sports Physiol Perform 2024; 19:347-355. [PMID: 38215734 DOI: 10.1123/ijspp.2023-0163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 10/14/2023] [Accepted: 11/30/2023] [Indexed: 01/14/2024]
Abstract
PURPOSE An inspiratory muscle warm-up (IMW) improves inspiratory muscle function, but the effects of high-intensity exercise are inconsistent. We aimed to determine the effects of high-intensity IMW on high-intensity exercise performance and muscle oxygenation. METHODS Ten healthy men (maximal oxygen uptake [V˙O2max] 52.2 [5.0] mL·kg-1·min-1) performed constant-load exercise to exhaustion on a cycle ergometer at V˙O2max under 2 IMW conditions: a placebo condition (PLA) and a high-intensity IMW condition (HIGH). The inspiratory loads were set at 15% and 80% of maximal inspiratory pressure, respectively. Maximal inspiratory pressure was measured before and after IMW. Oxyhemoglobin was measured in the vastus lateralis by near-infrared spectroscopy during exercise. Rating of perceived exertion (RPE) for a leg was measured after 1 and 2 minutes of exercise. RESULTS Exercise tolerance was significantly higher under HIGH than PLA (228 [49] s vs 218 [49] s, P = .003). Maximal inspiratory pressure was significantly increased by IMW under HIGH (from 125 [20] to 136 [25] cm H2O, P = .031). Oxyhemoglobin was significantly higher under HIGH than PLA at 80% of the total duration of exercise (P = .048). RPE for the leg was significantly lower under HIGH than PLA after 2 minutes of exercise (P = .019). CONCLUSIONS Given that oxyhemoglobin is an index of local oxygen supply, the results of this study suggest that high-intensity IMW increases the oxygen supply to active limbs. It may also reflect a reduction in RPE in the leg. In addition, high-intensity IMW may improve exercise performance.
Collapse
Affiliation(s)
- Jun Koizumi
- Graduate School of Health and Sport Science, Chukyo University, Aichi, Japan
| | - Toshiyuki Ohya
- Graduate School of Health and Sport Science, Chukyo University, Aichi, Japan
- School of Health and Sport Science, Chukyo University, Aichi, Japan
| |
Collapse
|
2
|
Soares de Araujo L, Marostegan AB, Menezes Scariot PP, Bordon Orsi J, Cirino C, Papoti M, Gobatto CA, Manchado-Gobatto FB. Inspiratory muscles pre-activation in young swimmers submitted to a tethered swimming test: effects on mechanical, physiological, and skin temperature parameters. Sci Rep 2024; 14:5975. [PMID: 38472356 DOI: 10.1038/s41598-024-52312-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/17/2024] [Indexed: 03/14/2024] Open
Abstract
Inspiratory muscles pre-activation (IMPA) has been studied to improve subsequent performance in swimming. However, the effects of IMPA on various parameters in swimmers are still unknown. Therefore, this study aimed to investigate the effects of IMPA on the mechanical parameters, physiological responses, and their possible correlations with swimming performance. A total of 14 young swimmers (aged 16 ± 0 years) underwent a 30-s all-out tethered swimming test, preceded or not by IMPA, a load of 40% of the maximal inspiratory pressure (MIP), and with a volume of 2 sets of 15 repetitions. The mechanical (strength, impulse, and fatigue index) and physiological parameters (skin temperature and lactatemia) and the assessment of perceived exertion and dyspnea were monitored in both protocols. The IMPA used did not increase the swimming force, and skin temperature, decrease blood lactate concentration, or subjective perception of exertion and dyspnea after the high-intensity tethered swimming exercises. Positive correlations were found between mean force and blood lactate (without IMPA: r = 0.62, P = 0.02; with IMPA: r = 0.65, P = 0.01). The impulse was positively correlated with blood lactate (without IMPA: r = 0.71, P < 0.01; with IMPA: r = 0.56, P = 0.03). Our results suggest that new IMPA protocols, possibly with increased volume, should be developed in order to improve the performance of young swimmers.
Collapse
Affiliation(s)
- Lara Soares de Araujo
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Anita Brum Marostegan
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Pedro Paulo Menezes Scariot
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Juan Bordon Orsi
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Carolina Cirino
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Marcelo Papoti
- Study and Research Group in Physiological Sciences and Exercise, School of Physical Education and Sport of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Claudio Alexandre Gobatto
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil
| | - Fúlvia Barros Manchado-Gobatto
- Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, Pedro Zaccaria Street, 1.300, Jardim Santa Luíza, Limeira, SP, 13484-350, Brazil.
| |
Collapse
|
3
|
Koizumi J, Ohya T. Effects of high-intensity inspiratory muscle warm-up on inspiratory muscle strength and accessory inspiratory muscle activity. Respir Physiol Neurobiol 2023; 313:104069. [PMID: 37141931 DOI: 10.1016/j.resp.2023.104069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/21/2023] [Accepted: 04/30/2023] [Indexed: 05/06/2023]
Abstract
This study aimed to determine the effects of work-matched moderate-intensity and high-intensity inspiratory muscle warm-up (IMW) on inspiratory muscle strength and accessory inspiratory muscle activity. Eleven healthy men performed three IMWs at different intensities, namely, placebo, moderate-intensity, and high-intensity, set, respectively, at 15%, 40%, and 80% of maximal inspiratory mouth pressure (MIP). MIP was measured before and after IMW. Electromyography (EMG) was recorded for the sternocleidomastoid muscle (SCM) and intercostal muscles (IC) during IMW. MIP increased significantly in the moderate-intensity condition (104.2 ± 5.1%, p<0.05) and high-intensity condition (106.5 ± 6.2%, p<0.01) after IMW. The EMG amplitudes of the SCM and IC during IMW were significantly higher in the order of high-intensity, moderate-intensity, and placebo conditions. There was a significant correlation between changes in MIP and EMG amplitude of the SCM (r=0.60, p<0.01) and IC (r=0.47, p<0.01) during IMW. These findings suggest that high-intensity IMW increases neuromuscular activity in the accessory inspiratory muscles, which may improve inspiratory muscle strength.
Collapse
Affiliation(s)
- Jun Koizumi
- Graduate School of Health and Sport Science, Chukyo University, Aichi, Japan.
| | - Toshiyuki Ohya
- Graduate School of Health and Sport Science, Chukyo University, Aichi, Japan; School of Health and Sport Science, Chukyo University, Aichi, Japan
| |
Collapse
|
4
|
Effects of Inspiratory Muscle Warm-Up on Physical Exercise: A Systematic Review. BIOLOGY 2023; 12:biology12020333. [PMID: 36829608 PMCID: PMC9953131 DOI: 10.3390/biology12020333] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 02/23/2023]
Abstract
This study aimed to systematically review the literature to examine the effects of inspiratory-muscle warm-up (IMW) on the inspiratory, metabolic, respiratory and performance parameters of a main exercise performed by athletes and healthy and active individuals. Methods: This systematic review included randomized studies in English based on the criteria of the PICOS model. The exclusion criteria adopted were studies that applied inspiratory exercise to: i. promote long-term adaptations through inspiratory training (chronic responses); ii. obtain acute responses to inspiratory load (overload) during and in breaks from physical effort and in an inspiratory-exercise session (acute training effect); iii. evaluate the effects of IMW on participants with cardiorespiratory and/or metabolic disease. Data Sources: PubMed, Embase, MedLine, Scopus, SPORTDiscus and Google Scholar (until 17 January 2023). Results: Thirty-one studies were selected. The performance and respiratory parameters were the most investigated (77% and 74%, respectively). Positive effects of IMW were reported by 88% of the studies that investigated inspiratory parameters and 45% of those that evaluated performance parameters. Conclusions: The analyzed protocols mainly had positive effects on the inspiratory and performance parameters of the physical exercises. These positive effects of IMW are possibly associated with the contractile and biochemical properties of inspiratory muscles.
Collapse
|
5
|
Effects of different inspiratory muscle warm-up loads on mechanical, physiological and muscle oxygenation responses during high-intensity running and recovery. Sci Rep 2022; 12:11223. [PMID: 35780133 PMCID: PMC9250525 DOI: 10.1038/s41598-022-14616-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 06/09/2022] [Indexed: 11/30/2022] Open
Abstract
Inspiratory muscle warm-up (IMW) has been used as a resource to enhance exercises and sports performance. However, there is a lack of studies in the literature addressing the effects of different IMW loads (especially in combination with a shorter and applicable protocol) on high-intensity running and recovery phase. Thus, this study aimed to investigate the effects of three different IMW loads using a shorter protocol on mechanical, physiological and muscle oxygenation responses during and after high-intensity running exercise. Sixteen physically active men, randomly performed four trials 30 s all-out run, preceded by the shorter IMW protocol (2 × 15 breaths with a 1-min rest interval between sets, accomplished 2 min before the 30 s all-out run). Here, three IMW load conditions were used: 15%, 40%, and 60% of maximal inspiratory pressure (MIP), plus a control session (CON) without the IMW. The force, velocity and running power were measured (1000 Hz). Two near-infrared spectroscopy (NIRS) devices measured (10 Hz) the muscle’s oxygenation responses in biceps brachii (BB) and vastus lateralis (VL). Additionally, heart rate (HR) and blood lactate ([Lac]) were also monitored. IMW loads applied with a shorter protocol promoted a significant increase in mean and minimum running power as well as in peak and minimum force compared to CON. In addition, specific IMW loads led to higher values of peak power, mean velocity (60% of MIP) and mean force (40 and 60% of MIP) in relation to CON. Physiological responses (HR and muscles oxygenation) were not modified by any IMW during exercise, as well as HR and [Lac] in the recovery phase. On the other hand, 40% of MIP presented a higher tissue saturation index (TSI) for BB during recovery phase. In conclusion, the use of different loads of IMW may improve the performance of a physically active individual in a 30 s all-out run, as verified by the increased peak, mean and minimum mechanical values, but not in performance assessed second by second. In addition, 40% of the MIP improves TSI of the BB during the recovery phase, which can indicate greater availability of O2 for lactate clearance.
Collapse
|
6
|
Cirino C, Gobatto CA, Pinto AS, Torres RS, Hartz CS, Azevedo PHSM, Moreno MA, Manchado-Gobatto FB. Complex network model indicates a positive effect of inspiratory muscles pre-activation on performance parameters in a judo match. Sci Rep 2021; 11:11148. [PMID: 34045508 PMCID: PMC8160163 DOI: 10.1038/s41598-021-90394-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 04/29/2021] [Indexed: 02/04/2023] Open
Abstract
This study investigated the effects of inspiratory muscle pre-activation (IMPA) on the interactions among the technical-tactical, physical, physiological, and psychophysiological parameters in a simulated judo match, based on the centrality metrics by complex network model. Ten male athletes performed 4 experimental sessions. Firstly, anthropometric measurements, maximal inspiratory pressure (MIP) and global strenght of the inspiratory muscles were determined. In the following days, all athletes performed four-minute video-recorded judo matches, under three conditions: without IMPA (CON), after IMPA at 15% (IMPA15), and at 40% (IMPA40) of MIP using an exerciser device. Blood lactate, heart rate and rating of perceived exertion were monitored, and the technical-tactical parameters during the match were related to offensive actions and the time-motion. Based on the complex network, graphs were constructed for each scenario (CON, IMPA15, and IMPA40) to investigate the Degree and Pagerank centrality metrics. IMPA40 increased the connectivity of the physical and technical-tactical parameters in complex network and highlighted the combat frequency and average combat time in top-five ranked nodes. IMPA15 also favoured the interactions among the psychophysiological, physical, and physiological parameters. Our results suggest the positive effects of the IMPA, indicating this strategy to prepare the organism (IMPA15) and to improve performance (IMPA40) in judo match.
Collapse
Affiliation(s)
- Carolina Cirino
- grid.411087.b0000 0001 0723 2494Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, 1300 Pedro Zaccaria St, Limeira, Sao Paulo 13484-350 Brazil
| | - Claudio A. Gobatto
- grid.411087.b0000 0001 0723 2494Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, 1300 Pedro Zaccaria St, Limeira, Sao Paulo 13484-350 Brazil
| | - Allan S. Pinto
- grid.411087.b0000 0001 0723 2494Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, 1300 Pedro Zaccaria St, Limeira, Sao Paulo 13484-350 Brazil
| | - Ricardo S. Torres
- grid.5947.f0000 0001 1516 2393Department of ICT and Natural Sciences, Norwegian University of Science and Technology, Ålesund, Norway
| | - Charlini S. Hartz
- grid.412397.a0000 0001 0271 5964Postgraduate Program in Human Movement Sciences, Methodist University of Piracicaba, Piracicaba, Sao Paulo Brazil
| | - Paulo H. S. M. Azevedo
- grid.411249.b0000 0001 0514 7202Department of Human Movement Sciences, Federal University of São Paulo, São Paulo, Brazil
| | - Marlene A. Moreno
- grid.412397.a0000 0001 0271 5964Postgraduate Program in Human Movement Sciences, Methodist University of Piracicaba, Piracicaba, Sao Paulo Brazil
| | - Fúlvia B. Manchado-Gobatto
- grid.411087.b0000 0001 0723 2494Laboratory of Applied Sport Physiology, School of Applied Sciences, University of Campinas, 1300 Pedro Zaccaria St, Limeira, Sao Paulo 13484-350 Brazil
| |
Collapse
|
7
|
Barnes KR, Ludge AR. Inspiratory Muscle Warm-up Improves 3,200-m Running Performance in Distance Runners. J Strength Cond Res 2021; 35:1739-1747. [PMID: 30640308 DOI: 10.1519/jsc.0000000000002974] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
ABSTRACT Barnes, KR and Ludge, AR. Inspiratory muscle warm-up improves 3,200-m running performance in distance runners. J Strength Cond Res 35(6): 1739-1747, 2021-This study examined the effects of an inspiratory muscle exercise as part of a warm-up (IMW) using a resisted breathing trainer on running performance. In a randomized crossover design, 17 trained distance runners completed two 3,200-m performance trials on separate days, preceded by 2 different warm-up procedures: IMW or sham IMW (CON). In each condition, subjects performed 30 breaths against either 50% of each athlete's peak strength (IMW) or 30 slow protracted breaths against negligible resistance (CON). Perceived race readiness and inspiratory muscle strength, flow, power, and volume were measured before and after each warm-up. Heart rate (HR), rating of perceived exertion (RPE) and dyspnea (RPD), and expired gases were collected during each trial. A 3,200-m run performance was 2.8% ± 1.5% (20.4-second) faster after IMW (effect size [ES] = 0.37, p = 0.02). After each warm-up condition, there was as small effect on peak inspiratory strength (6.6 ± 4.8%, ES = 0.22, p = 0.02), flow (5.2 ± 4.4%, ES = 0.20, p = 0.03), power (17.6 ± 16.7%, ES = 0.22, p = 0.04), and volume (6.7 ± 6.3%, ES = 0.24, p = 0.01) after IMW compared with CON. There were no differences in HR, minute volume, peak V̇o2, or V̇o2 at each 800-m interval between conditions (ES ≤ 0.13, p > 0.17). There were small differences in RPE at 800 m and 1,600 m (ES = 0.32, p = 0.17; ES = 0.21, p = 0.38, respectively), but no difference at the last 1,600 m (p = 1.0). There was a moderate positive effect on RPD (ES = 0.81, p < 0.001) and race readiness (ES = 0.76, p < 0.01) after IMW. Overall, the data suggest that IMW improves 3,200-m performance because of enhancements in inspiratory muscle function characteristics and reduction in dyspnea.
Collapse
Affiliation(s)
- Kyle R Barnes
- Department of Movement Science, Grand Valley State University, Allendale, Michigan
| | | |
Collapse
|
8
|
Hardy TA, How SC, Taylor BJ. The Effect of Preexercise Expiratory Muscle Loading on Exercise Tolerance in Healthy Men. Med Sci Sports Exerc 2021; 53:421-430. [PMID: 32735113 DOI: 10.1249/mss.0000000000002468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PURPOSE Acute nonfatiguing inspiratory muscle loading transiently increases diaphragm excitability and global inspiratory muscle strength and may improve subsequent exercise performance. We investigated the effect of acute expiratory muscle loading on expiratory muscle function and exercise tolerance in healthy men. METHODS Ten males cycled at 90% of peak power output to the limit of tolerance (TLIM) after 1) 2 × 30 expiratory efforts against a pressure-threshold load of 40% maximal expiratory gastric pressure (PgaMAX) (EML-EX) and 2) 2 × 30 expiratory efforts against a pressure-threshold load of 10% PgaMAX (SHAM-EX). Changes in expiratory muscle function were assessed by measuring the mouth pressure (PEMAX) and PgaMAX responses to maximal expulsive efforts and magnetically evoked (1 Hz) gastric twitch pressure (Pgatw). RESULTS Expiratory loading at 40% of PgaMAX increased PEMAX (10% ± 5%, P = 0.001) and PgaMAX (9% ± 5%, P = 0.004). Conversely, there was no change in PEMAX (166 ± 40 vs 165 ± 35 cm H2O, P = 1.000) or PgaMAX (196 ± 38 vs 192 ± 39 cm H2O, P = 0.215) from before to after expiratory loading at 10% of PgaMAX. Exercise time was not different in EML-EX versus SHAM-EX (7.91 ± 1.96 vs 8.09 ± 1.77 min, 95% CI = -1.02 to 0.67, P = 0.651). Similarly, exercise-induced expiratory muscle fatigue was not different in EML-EX versus SHAM-EX (-28% ± 12% vs -26% ± 7% reduction in Pgatw amplitude, P = 0.280). Perceptual ratings of dyspnea and leg discomfort were not different during EML-EX versus SHAM-EX. CONCLUSION Acute expiratory muscle loading enhances expiratory muscle function but does not improve subsequent severe-intensity exercise tolerance in healthy men.
Collapse
Affiliation(s)
- Tim A Hardy
- Faculty of Biological Sciences, School of Biomedical Sciences, University of Leeds, Leeds, UNITED KINGDOM
| | - Stephen C How
- School of Sport and Exercise, University of Gloucestershire, Gloucester, UNITED KINGDOM
| | | |
Collapse
|
9
|
Cheng CF, Hsu WC, Kuo YH, Chen TW, Kuo YC. Acute effect of inspiratory resistive loading on sprint interval exercise performance in team-sport athletes. Respir Physiol Neurobiol 2020; 282:103531. [PMID: 32827709 DOI: 10.1016/j.resp.2020.103531] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 07/24/2020] [Accepted: 08/16/2020] [Indexed: 11/28/2022]
Abstract
This study examined acute effects of inspiratory resistive loading (IRL) during rest intervals on sprint interval exercise (SIE) performance. In a randomized crossover design, nine collegiate basketball players performed IRL (15 cmH2O) or passive recovery (CON) at 5-min rest intervals during and immediately after 6 sets of a 30-s SIE test. Performance, muscular oxygenation of vastus lateralis, blood lactate and pH were measured at each condition. Blood lactate at 5-min (-20.5 %) and 20-min (-21.3 %) after SIE were significantly lower in IRL than in CON. The pH at 5-min after SIE was significantly higher in IRL than in CON (+0.8 %, p < 0.05). However, the total work in IRL was significantly lower than in CON (-2.7 %, p < 0.05). Average changes in total hemoglobin at rest intervals in IRL were significantly lower than in CON (-34.5 %, p < 0.05). The IRL could attenuate exercise-induced metabolic acidosis; however, the decreased blood flow at rest intervals might increase the physical challenge in SIE.
Collapse
Affiliation(s)
- Ching-Feng Cheng
- Department of Athletic Performance, National Taiwan Normal University, Taipei, Taiwan; Sports Performance Lab, National Taiwan Normal University, Taipei, Taiwan.
| | - Wei-Chieh Hsu
- Sports Performance Lab, National Taiwan Normal University, Taipei, Taiwan; Graduate Institute of Sports Training, University of Taipei, Taipei, Taiwan
| | - Yu-Hsuan Kuo
- Sports Performance Lab, National Taiwan Normal University, Taipei, Taiwan; Department of Physical Education, Chinese Culture University, Taipei, Taiwan
| | - Tzu-Wei Chen
- Physical Education Office, National Chengchi University, Taipei, Taiwan
| | - Yu-Chi Kuo
- Department of Exercise and Health Science, National Taipei University of Nursing and Health Sciences, Taipei, Taiwan
| |
Collapse
|
10
|
Richard P, Billaut F. Effects of inspiratory muscle warm-up on locomotor muscle oxygenation in elite speed skaters during 3000 m time trials. Eur J Appl Physiol 2018; 119:191-200. [PMID: 30350154 DOI: 10.1007/s00421-018-4015-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 10/10/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE It has been shown that an inspiratory muscle warm-up (IMW) could enhance performance. IMW may also improve the near-infrared spectroscopy (NIRS)-derived tissue oxygen saturation index (TSI) during cycling. However, there exists contradictory data about the effect of this conditioning strategy on performance and muscle oxygenation. We examined the effect of IMW on speed skating performance and studied the underpinning physiological mechanisms related to muscle oxygenation. METHODS In a crossover, randomized, single-blind study, eight elite speed skaters performed 3000 m on-ice time trials, preceded by either IMW (2 × 30 breaths, 40% maximal inspiratory pressure) or SHAM (2 × 30 breaths, 15% maximal inspiratory pressure). Changes in TSI, oxyhemoglobin-oxymyoglobin ([O2HbMb]), deoxyhemoglobin-deoxymyoglobin ([HHbMb]), total hemoglobin-myoglobin ([THbMb]) and HHbMbdiff ([O2HbMb]-[HHbMb]) in the right vastus lateralis muscle were monitored by NIRS. All variables were compared at different time points of the race simulation with repeated-measures analysis of variance. Differences between IMW and SHAM were also analyzed using Cohen's effect size (ES) ± 90% confidence limits, and magnitude-based inferences. RESULTS Compared with SHAM, IMW had no clear impact on skating time (IMW 262.88 ± 17.62 s vs. SHAM 264.05 ± 21.12 s, effect size (ES) 0.05; 90% confidence limits, - 0.22, 0.32, p = 0.7366), TSI, HbMbdiff, [THbMb], [O2HbMb] and perceptual responses. CONCLUSIONS IMW did not modify skating time during a 3000 m time trial in speed skaters, in the conditions of our study. The unchanged [THbMb] and TSI demonstrate that the mechanisms by which IMW could possibly exert an effect on performance were unaffected by this intervention.
Collapse
Affiliation(s)
- Philippe Richard
- Département de kinésiologie, Université Laval, 2300, rue de la Terrasse, Quebec, QC, G1V 0A6, Canada
| | - François Billaut
- Département de kinésiologie, Université Laval, 2300, rue de la Terrasse, Quebec, QC, G1V 0A6, Canada.
| |
Collapse
|
11
|
Özdal M, Bostanci Ö. Influence of inspiratory muscle warm-up on aerobic performance during incremental exercise. ISOKINET EXERC SCI 2018. [DOI: 10.3233/ies-172188] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Mustafa Özdal
- Department of Physical Education and Sport, Gaziantep University Performance Laboratory, Gaziantep University, Gaziantep, Turkey
| | - Özgür Bostanci
- Sport Science Faculty, Ondokuz Mayıs University, Samsun, Turkey
| |
Collapse
|
12
|
Richard P, Billaut F. Combining Chronic Ischemic Preconditioning and Inspiratory Muscle Warm-Up to Enhance On-Ice Time-Trial Performance in Elite Speed Skaters. Front Physiol 2018; 9:1036. [PMID: 30108521 PMCID: PMC6079196 DOI: 10.3389/fphys.2018.01036] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Accepted: 07/12/2018] [Indexed: 02/02/2023] Open
Abstract
Elite athletes in varied sports typically combine ergogenic strategies in the hope of enhancing physiological responses and competitive performance, but the scientific evidence for such practices is very scarce. The peculiar characteristics of speed skating contribute to impede blood flow and exacerbate deoxygenation in the lower limbs (especially the right leg). We investigated whether combining preconditioning strategies could modify muscular oxygenation and improve performance in that sport. Using a randomized, single-blind, placebo-controlled, crossover design, seven male elite long-track speed skaters performed on-ice 600-m time trials, preceded by either a combination of preconditioning strategies (COMBO) or a placebo condition (SHAM). COMBO involved performing remote ischemic preconditioning (RIPC) of the upper limbs (3 × 5-min compression at 180 mmHg and 5-min reperfusion) over 3 days (including an acute treatment before trials), with the addition of an inspiratory muscle warm-up [IMW: 2 × 30 inspirations at 40% maximal inspiratory pressure (MIP)] on the day of testing. SHAM followed the same protocol with lower intensities (10 mmHg for RIPC and 15% MIP). Changes in tissue saturation index (TSI), oxyhemoglobin–oxymyoglobin ([O2HbMb]), deoxyhemoglobin–deoxymyoglobin ([HHbMb]), and total hemoglobin–myoglobin ([THbMb]) in the right vastus lateralis muscle were monitored by near-infrared spectroscopy (NIRS). Differences between COMBO and SHAM were analyzed using Cohen’s effect size (ES) and magnitude-based inferences. Compared with SHAM, COMBO had no worthwhile effect on performance time while mean Δ[HHbMb] (2.7%, ES 0.48; -0.07, 1.03) and peak Δ[HHbMb] (1.8%, ES 0.23; -0.10, 0.57) were respectively likely and possibly higher in the last section of the race. These results indicate that combining ischemic preconditioning and IMW has no practical ergogenic impact on 600-m speed-skating performance in elite skaters. The low-sitting position in this sport might render difficult enhancing these physiological responses.
Collapse
Affiliation(s)
- Philippe Richard
- Département de kinésiologie, Université Laval, Quebec, QC, Canada
| | - François Billaut
- Département de kinésiologie, Université Laval, Quebec, QC, Canada
| |
Collapse
|
13
|
Rodriguez RF, Townsend NE, Aughey RJ, Billaut F. Influence of averaging method on muscle deoxygenation interpretation during repeated-sprint exercise. Scand J Med Sci Sports 2018; 28:2263-2271. [PMID: 29883534 DOI: 10.1111/sms.13238] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/04/2018] [Indexed: 11/27/2022]
Abstract
Near-infrared spectroscopy (NIRS) is a common tool used to study oxygen availability and utilization during repeated-sprint exercise. However, there are inconsistent methods of smoothing and determining peaks and nadirs from the NIRS signal, which make interpretation and comparisons between studies difficult. To examine the effects of averaging method on deoxyhaemoglobin concentration ([HHb]) trends, nine males performed ten 10-s sprints, with 30 seconds of recovery, and six analysis methods were used for determining peaks and nadirs in the [HHb] signal. First, means were calculated over predetermined windows in the last 5 and 2 seconds of each sprint and recovery period. Second, moving 5-seconds and 2-seconds averages were also applied, and peaks/nadirs were determined for each 40-seconds sprint/recovery cycle. Third, a Butterworth filter was used to smooth the signal, and the resulting signal output was used to determine peaks and nadirs from predetermined time points and a rolling approach. Correlation and residual analysis showed that the Butterworth filter attenuated the "noise" in the signal, while maintaining the integrity of the raw data (r = .9892; mean standardized residual -9.71 × 103 ± 3.80). Means derived from predetermined windows, irrespective of length and data smoothing, underestimated the magnitude of peak and nadir [HHb] compared to a rolling mean approach. Consequently, sprint-induced metabolic changes (inferred from Δ[HHb]) were underestimated. Based on these results, we suggest using a digital filter to smooth NIRS data, rather than an arithmetic mean, and a rolling approach to determine peaks and nadirs for accurate interpretation of muscle oxygenation trends.
Collapse
Affiliation(s)
- R F Rodriguez
- Institute for Health and Sport, Victoria University, Melbourne, Australia
| | | | - R J Aughey
- Institute for Health and Sport, Victoria University, Melbourne, Australia
| | - F Billaut
- Institute for Health and Sport, Victoria University, Melbourne, Australia.,Department of kinesiology, University Laval, Quebec, Canada
| |
Collapse
|
14
|
Odunayo A, Tobias KM, Okafor CC, Flatland B. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter. Am J Vet Res 2018; 78:1239-1244. [PMID: 29076371 DOI: 10.2460/ajvr.78.11.1239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.
Collapse
|
15
|
Özdal M, Bostanci Ö, Dağlioğlu Ö, Ağaoğlu SA, Kabadayi M. Effect of respiratory warm-up on anaerobic power. J Phys Ther Sci 2016; 28:2097-8. [PMID: 27512273 PMCID: PMC4968514 DOI: 10.1589/jpts.28.2097] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 04/07/2016] [Indexed: 11/24/2022] Open
Abstract
[Purpose] The aim of the present study was to examine the effects of respiratory muscle warm-up on anaerobic power. [Subjects and Methods] Thirty male field hockey players (age, 20.5 ± 2.0 years) each participated in a control (CAN) trial and an experimental (EAN) trial. The EAN trial involved respiratory muscle warm-up, while the CAN trial did not. Anaerobic power was measured using the Wingate protocol. Paired sample t-tests were used to compare the EAN and CAN trials. [Results] There were significant increases in peak power and relative peak power, and decreases in the time to peak after the EAN trial by 8.9%, 9.6%, and 28.8% respectively. [Conclusion] Respiratory muscle warm-up may positively affect anaerobic power due to faster attainment of peak power.
Collapse
Affiliation(s)
- Mustafa Özdal
- Department of Physical Education and Sports, School of Physical Education and Sport, Gaziantep University, Turkey
| | - Özgür Bostanci
- Department of Physical Education and Sports, Faculty of Sport Science, Ondokuz Mayis University, Turkey
| | - Önder Dağlioğlu
- Department of Physical Education and Sports, School of Physical Education and Sport, Gaziantep University, Turkey
| | - Seydi Ahmet Ağaoğlu
- Department of Physical Education and Sports, Faculty of Sport Science, Ondokuz Mayis University, Turkey
| | - Menderes Kabadayi
- Department of Physical Education and Sports, Faculty of Sport Science, Ondokuz Mayis University, Turkey
| |
Collapse
|
16
|
Özdal M. Acute effects of inspiratory muscle warm-up on pulmonary function in healthy subjects. Respir Physiol Neurobiol 2016; 227:23-6. [DOI: 10.1016/j.resp.2016.02.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 01/19/2016] [Accepted: 02/17/2016] [Indexed: 10/22/2022]
|
17
|
|
18
|
Ohya T, Hagiwara M, Suzuki Y. Inspiratory muscle warm-up has no impact on performance or locomotor muscle oxygenation during high-intensity intermittent sprint cycling exercise. SPRINGERPLUS 2015; 4:556. [PMID: 26435902 PMCID: PMC4586185 DOI: 10.1186/s40064-015-1355-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Accepted: 09/20/2015] [Indexed: 12/03/2022]
Abstract
The purpose of this study was to investigate the effect of inspiratory muscle (IM) warm-up on performance and locomotor muscle oxygenation during high-intensity intermittent sprint cycling exercise. Ten subjects performed identical exercise tests (10 × 5 s with 25-s recovery on a cycle ergometer) after performing one of two different IM warm-up protocols. The IM warm-up consisted of two sets of 30 inspiratory efforts against a pressure-threshold load equivalent to 15 % (PLA) or 40 % (IMW) of maximal inspiratory pressure (MIP). MIP was measured with a portable autospirometer. Peak power and percent decrease in power were determined. Oxyhemoglobin (O2Hb) was measured using near-infrared spectroscopy. The MIP increased relative to baseline after IMW (115 ± 21 vs. 123 ± 17 cmH2O, P = 0.012, ES = 0.42), but not after PLA (115 ± 20 vs. 116 ± 17 cmH2O). Peak power (PLA: 10.0 ± 0.6 vs. IMW: 10.2 ± 0.5 W kg−1), percent decrease in power (PLA: 13.4 ± 5.6 vs. IMW: 13.2 ± 5.5 %), and changes in O2Hb levels (PLA: −10.8 ± 4.8 vs. −10.7 ± 4.1 μM) did not differ between the trials. IM function was improved by IMW. However, this did not enhance performance or locomotor muscle oxygenation during high-intensity intermittent sprint cycling exercise in untrained healthy males.
Collapse
Affiliation(s)
- Toshiyuki Ohya
- Department of Sports Science, Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056 Japan
| | - Masahiro Hagiwara
- Department of Sports Science, Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056 Japan
| | - Yasuhiro Suzuki
- Department of Sports Science, Japan Institute of Sports Sciences, 3-15-1 Nishigaoka, Kita-ku, Tokyo, 115-0056 Japan
| |
Collapse
|
19
|
Johnson MA, Gregson IR, Mills DE, Gonzalez JT, Sharpe GR. Inspiratory muscle warm-up does not improve cycling time-trial performance. Eur J Appl Physiol 2014; 114:1821-30. [PMID: 24878690 DOI: 10.1007/s00421-014-2914-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Accepted: 05/15/2014] [Indexed: 11/30/2022]
Abstract
PURPOSE This study examined the effects of an active cycling warm-up, with and without the addition of an inspiratory muscle warm-up (IMW), on 10-km cycling time-trial performance. METHODS Ten cyclists (VO₂ = 65 ± 9 mL kg(-1) min(-1)) performed a habituation 10-km cycling time-trial and three further time-trials preceded by either no warm-up (CONT), a cycling-specific warm-up (CYC) comprising three consecutive 5-min bouts at powers corresponding to 70, 80, and 90% of the gas exchange threshold, or a cycling-specific warm-up preceded by an IMW (CYC + IMW) comprising two sets of 30 inspiratory efforts against a pressure-threshold load of 40% maximal inspiratory pressure (MIP). The cycling warm-up was followed by 2-min rest before the start of the time-trial. RESULTS Time-trial performance times during CYC (14.75 ± 0.79 min) and CYC + IMW (14.70 ± 0.75 min) were not different, although both were faster than CONT (14.99 ± 0.90 min) (P < 0.05). Throughout the time-trial, physiological (minute ventilation, breathing pattern, pulmonary gas exchange, heart rate, blood lactate concentration and pH) and perceptual (limb discomfort and dyspnoea) responses were not different between CYC and CYC + IMW. Baseline MIP during CONT and CYC was 151 ± 31 and 156 ± 39 cmH₂O, respectively, and was unchanged following the time-trial. MIP increased by 8% after IMW (152 ± 27 vs. 164 ± 27 cmH2O, P < 0.05) and returned to baseline after the time-trial. CONCLUSIONS Improvements in 10-km cycling time-trial performance following an active cycling warm-up were not magnified by the addition of an IMW. Therefore, an appropriately designed active whole-body warm-up does adequately prepare the inspiratory muscles for cycling time-trials lasting approximately 15 min.
Collapse
Affiliation(s)
- M A Johnson
- Sport, Health and Performance Enhancement (SHAPE) Research Group, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, UK,
| | | | | | | | | |
Collapse
|
20
|
Evaluation of a textile-based near infrared spectroscopy system in calf muscle oxygenation measurements. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2014. [PMID: 24729254 DOI: 10.1007/978-1-4939-0620-8_47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
We recently introduced a novel textile-based NIRS sensor (TexNIRS). Here, we evaluate TexNIRS in ten subjects (16 legs, age 28.5 ± 2.32 years, adipose tissue thickness (ATT) 4.17 ± 1.71 mm). Three venous occlusions at 50 mmHg were performed on their calf muscle. After 3 min of occlusion, oxy/deoxy hemoglobin concentration ([O₂Hb], [HHb]) changes were 3.71 ± 1.89/1.79 ± 1.08 μM; venous oxygen saturation (SvO₂) was 75 ± 9.7 %, oxygen consumption (VO₂) was 0.02 ± 0.01 mL/100 g/min, hemoglobin flow (HF) was 0.93 ± 0.48 μmol/100 mL/min, and blood flow (BF) was 2.01 ± 1.04 mL/100 mL/min. Our results are in good agreement with the literature, but the TexNIRS enables a much higher level of comfort.
Collapse
|