1
|
Cardenas Perez AS, Challis JK, Alcaraz AJ, Ji X, Ramirez AVV, Hecker M, Brinkmann M. Developing an Approach for Integrating Chemical Analysis and Transcriptional Changes to Assess Contaminants in Water, Sediment, and Fish. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY 2024; 43:2252-2273. [PMID: 38801401 DOI: 10.1002/etc.5886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 04/01/2024] [Accepted: 04/10/2024] [Indexed: 05/29/2024]
Abstract
Pharmaceuticals in aquatic environments pose threats to aquatic organisms because of their continuous release and potential accumulation. Monitoring methods for these contaminants are inadequate, with targeted analyses falling short in assessing water quality's impact on biota. The present study advocates for integrated strategies combining suspect and targeted chemical analyses with molecular biomarker approaches to better understand the risks posed by complex chemical mixtures to nontarget organisms. The research aimed to integrate chemical analysis and transcriptome changes in fathead minnows to prioritize contaminants, assess their effects, and apply this strategy in Wascana Creek, Canada. Analysis revealed higher pharmaceutical concentrations downstream of a wastewater-treatment plant, with clozapine being the most abundant in fathead minnows, showing notable bioavailability from water and sediment sources. Considering the importance of bioaccumulation factor and biota-sediment accumulation factor in risk assessment, these coefficients were calculated based on field data collected during spring, summer, and fall seasons in 2021. Bioaccumulation was classified as very bioaccumulative with values >5000 L kg-1, suggesting the ability of pharmaceuticals to accumulate in aquatic organisms. The study highlighted the intricate relationship between nutrient availability, water quality, and key pathways affected by pharmaceuticals, personal care products, and rubber components. Prioritization of these chemicals was done through suspect analysis, supported by identifying perturbed pathways (specifically signaling and cellular processes) using transcriptomic analysis in exposed fish. This strategy not only aids in environmental risk assessment but also serves as a practical model for other watersheds, streamlining risk-assessment processes to identify environmental hazards and work toward reducing risks from contaminants of emerging concern. Environ Toxicol Chem 2024;43:2252-2273. © 2024 SETAC.
Collapse
Affiliation(s)
- Ana Sharelys Cardenas Perez
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Global Institute for Water Security, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Alper James Alcaraz
- Toxicology Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Xiaowen Ji
- Division of Environmental Pediatrics, Department of Pediatrics, Grossman School of Medicine, New York University, New York, New York, USA
| | - Alexis Valerio Valery Ramirez
- Grupo de investigación Agrícola y Ambiental, Universidad Nacional Experimental del Táchira, San Cristóbal, Venezuela
| | - Markus Hecker
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Global Institute for Water Security, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Toxicology Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Markus Brinkmann
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Global Institute for Water Security, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Toxicology Centre, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Centre for Hydrology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| |
Collapse
|
2
|
Barros de Souza A, Ali I, van de Goor T, Dewil R, Cabooter D. Comprehensive two-dimensional liquid chromatography with high resolution mass spectrometry to investigate the photoelectrochemical degradation of environmentally relevant pharmaceuticals and their degradation products in water. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 351:120023. [PMID: 38181683 DOI: 10.1016/j.jenvman.2024.120023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/26/2023] [Accepted: 01/02/2024] [Indexed: 01/07/2024]
Abstract
The widespread presence of organic micropollutants in the environment reflects the inability of traditional wastewater treatment plants to remove them. In this context, advanced oxidation processes (AOPs) have emerged as promising quaternary wastewater treatment technologies since they efficiently degrade recalcitrant components by generating highly reactive free radicals. Nonetheless, the chemical characterization of potentially harmful byproducts is essential to avoid the contamination of natural water bodies with hazardous substances. Given the complexity of wastewater matrices, the implementation of comprehensive analytical methodologies is required. In this work, the simultaneous photoelectrochemical degradation of seven environmentally relevant pharmaceuticals and one metabolite from the EU Watch List 2020/1161 was examined in ultrapure water and simulated wastewater, achieving excellent removal efficiencies (overall >95%) after 180 min treatment. The reactor unit was linked to an online LC sample manager, allowing for automated sampling every 15 min and near real-time process monitoring. Online comprehensive two-dimensional liquid chromatography (LC × LC) coupled with high resolution mass spectrometry (HRMS) was subsequently used to tentatively identify degradation products after photoelectrochemical degradation. Two reversed-phase liquid chromatography (RPLC) columns were used: an SB-C18 column operated with 5 mM ammonium formate at pH 5.8 (1A) and methanol (1B) as the mobile phases in the first dimension and an SB-Aq column using acidified water at pH 3.1 (2A) and acetonitrile (2B) as the mobile phases in the second dimension. This resulted in a five-fold increase in peak capacity compared to one-dimensional LC while maintaining the same total analysis time of 50 min. The LC x LC method allowed the tentative identification of 12 venlafaxine, 7 trimethoprim and 10 ciprofloxacin intermediates. Subsequent toxicity predictions suggested that some of these byproducts were potentially harmful. This study presents an effective hybrid technology for the simultaneous removal of pharmaceuticals from contaminated wastewater matrices and demonstrates how multidimensional liquid chromatography techniques can be applied to better understand the degradation mechanisms after the treatment of micropollutants with AOPs.
Collapse
Affiliation(s)
- Allisson Barros de Souza
- Agilent Technologies Deutschland, Hewlett-Packard-Strasse 8, 76337, Waldbronn, Germany; KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, 3000, Leuven, Belgium
| | - Izba Ali
- InOpSys - Mobiele Waterzuivering voor Chemie en Farma, Maanstraat 9b, 2800, Mechelen, Belgium; KU Leuven, Department of Chemical Engineering, Process and Environmental Technology Lab, J. De Nayerlaan 5, 2860, Sint-Katelijne-Waver, Belgium
| | - Tom van de Goor
- Agilent Technologies Deutschland, Hewlett-Packard-Strasse 8, 76337, Waldbronn, Germany
| | - Raf Dewil
- KU Leuven, Department of Chemical Engineering, Process and Environmental Technology Lab, J. De Nayerlaan 5, 2860, Sint-Katelijne-Waver, Belgium; University of Oxford, Department of Engineering Science, Parks Road, Oxford, OX1 3PJ, United Kingdom
| | - Deirdre Cabooter
- KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, 3000, Leuven, Belgium.
| |
Collapse
|
3
|
Kochale K, Cunha R, Teutenberg T, Schmidt TC. Development of a column switching for direct online enrichment and separation of polar and nonpolar analytes from aqueous matrices. J Chromatogr A 2024; 1714:464554. [PMID: 38065029 DOI: 10.1016/j.chroma.2023.464554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 01/05/2024]
Abstract
Trace substances in surface waters may threaten health and pose a risk for the aquatic environment. Moreover, separation and detection by instrumental analysis is challenging due to the low concentration and the wide range of polarities. Separation of polar and nonpolar analytes can be achieved by using stationary phases with different selectivity. Lower limits of detection of trace substances can be obtained by offline enrichment on solid phase materials. However, these practices require substantial effort and are time consuming and costly. Therefore, in this study, a column switching was developed to enrich and separate both polar and nonpolar analytes by an on-column large volume injection of aqueous samples. The column switching can significantly reduce the effort and time for analyzing trace substances without compromising on separation and detection. A reversed phase (RP) column is used to trap the nonpolar analytes. The polar analytes are enriched on a porous graphitized carbon column (PGC) coupled serially behind the RP column. A novel valve switching system is implemented to enable elution of the nonpolar analytes from the RP column and, subsequently, elution of polar analytes from the PGC column and separation on a hydrophilic interaction liquid chromatography (HILIC) column. To enable separation of polar analytes dissolved in an aqueous matrix by HILIC, the water plug that is flushed from the PGC column is diluted by dosing organic solvent directly upstream of the HILIC column. The developed method was tested by applying target analysis and non-target screening, highlighting the advantage to effectively separate and detect both polar and nonpolar compounds in a single chromatographic run. In the target analysis, the analytes, with a logD at pH 3 ranging from -2.8 to + 4.5, could be enriched and separated. Besides the 965 features in the RP phase, 572 features from real wastewater were observed in the HILIC phase which would otherwise elute in the void time in conventional one-dimensional RP methods.
Collapse
Affiliation(s)
- Kjell Kochale
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany; Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141 Essen, Germany
| | - Ricardo Cunha
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany
| | - Thorsten Teutenberg
- Institut für Umwelt & Energie, Technik & Analytik e. V. (IUTA), Bliersheimer Str. 58-60, 47229 Duisburg, Germany.
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, 45141 Essen, Germany
| |
Collapse
|
4
|
Duarte RMBO, Brandão PF, Duarte AC. Multidimensional chromatography in environmental analysis: Comprehensive two-dimensional liquid versus gas chromatography. J Chromatogr A 2023; 1706:464288. [PMID: 37573757 DOI: 10.1016/j.chroma.2023.464288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 07/22/2023] [Accepted: 08/07/2023] [Indexed: 08/15/2023]
Abstract
Analysis of complex environmental matrices poses an extreme challenge for analytical chemists due to the vast number of known and unknown compounds, with very diverse chemical and physical properties. The need for a holistic characterisation of this complexity has sparked the development of effective tools to unravel the chemical composition of such environmental samples. Multidimensional chromatographic methods, namely comprehensive two-dimensional (2D) gas and liquid chromatography (GC × GC and LC × LC, respectively), coupled to different detection systems have emerged as powerful tools with the capability to address this challenge. While GC × GC has steadily gained popularity in environmental analysis, LC × LC is surprisingly less attractive in this research field. This critical review article explores the potential reasons why LC × LC is not the dominant technique used in environmental analysis as compared to GC × GC, while simultaneously highlighting the quite unique role of LC × LC for the target and untargeted analysis of complex environmental matrices. The possible combinations of stationary phases, the important role of the interfacing valve as the heart of an LC × LC assembly, the existing optimization strategies for improving the separation power in the 2D chromatographic space, and the need for user-friendly mathematical tools for multidimensional data handling are also discussed. Finally, a set of practical measures are suggested to increase the use and secure the success of LC × LC in environmental analysis.
Collapse
Affiliation(s)
- Regina M B O Duarte
- Department of Chemistry, CESAM - Centre for Environmental and Marine Studies, University of Aveiro, Aveiro 3810-193, Portugal.
| | - Pedro F Brandão
- Department of Chemistry, CESAM - Centre for Environmental and Marine Studies, University of Aveiro, Aveiro 3810-193, Portugal
| | - Armando C Duarte
- Department of Chemistry, CESAM - Centre for Environmental and Marine Studies, University of Aveiro, Aveiro 3810-193, Portugal
| |
Collapse
|
5
|
Renner G, Reuschenbach M. Critical review on data processing algorithms in non-target screening: challenges and opportunities to improve result comparability. Anal Bioanal Chem 2023; 415:4111-4123. [PMID: 37380744 PMCID: PMC10328864 DOI: 10.1007/s00216-023-04776-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 04/23/2023] [Accepted: 05/15/2023] [Indexed: 06/30/2023]
Abstract
Non-target screening (NTS) is a powerful environmental and analytical chemistry approach for detecting and identifying unknown compounds in complex samples. High-resolution mass spectrometry has enhanced NTS capabilities but created challenges in data analysis, including data preprocessing, peak detection, and feature extraction. This review provides an in-depth understanding of NTS data processing methods, focusing on centroiding, extracted ion chromatogram (XIC) building, chromatographic peak characterization, alignment, componentization, and prioritization of features. We discuss the strengths and weaknesses of various algorithms, the influence of user input parameters on the results, and the need for automated parameter optimization. We address uncertainty and data quality issues, emphasizing the importance of incorporating confidence intervals and raw data quality assessment in data processing workflows. Furthermore, we highlight the need for cross-study comparability and propose potential solutions, such as utilizing standardized statistics and open-access data exchange platforms. In conclusion, we offer future perspectives and recommendations for developers and users of NTS data processing algorithms and workflows. By addressing these challenges and capitalizing on the opportunities presented, the NTS community can advance the field, improve the reliability of results, and enhance data comparability across different studies.
Collapse
Affiliation(s)
- Gerrit Renner
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, Essen, D-45141, NRW, Germany.
- Centre for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 2, Essen, D-45141, NRW, Germany.
| | - Max Reuschenbach
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, Essen, D-45141, NRW, Germany
- Centre for Water and Environmental Research (ZWU), University of Duisburg-Essen, Universitätsstr. 2, Essen, D-45141, NRW, Germany
| |
Collapse
|
6
|
Mechanistic investigation of phosphonate photolysis in aqueous solution by simultaneous LC-IRMS and HRMS analysis. J Photochem Photobiol A Chem 2023. [DOI: 10.1016/j.jphotochem.2023.114582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
7
|
Sá MFT, Castro V, Gomes AI, Morais DFS, Silva Braga RVPS, Saraiva I, Souza-Chaves BM, Park M, Fernández-Fernández V, Rodil R, Montes R, Quintana JB, Vilar VJP. Tracking pollutants in a municipal sewage network impairing the operation of a wastewater treatment plant. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 817:152518. [PMID: 34995583 DOI: 10.1016/j.scitotenv.2021.152518] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 11/26/2021] [Accepted: 12/14/2021] [Indexed: 06/14/2023]
Abstract
This work provides a screening of organic contaminants and characterization of the dissolved organic matter in the sewer network until the municipal wastewater treatment plant (WWTP), identifying the network areas with a higher degree of contamination and their impact on the WWTP performance, particularly in the activated sludge reactor. Three monitoring campaigns were carried out at six selected locations of the sewage system (PVZ-1, PVZ-2, PS-F, PS-VC, CP-VC, and PS-T), influent (WWTPINF) and effluent (WWTPEFF) of the WWTP. Advanced analytical techniques were employed, namely excitation/emission matrix fluorescence-parallel factor analysis (EEM-PARAFAC), size exclusion chromatography with organic carbon detector (SEC-OCD), and liquid chromatography with high-resolution-mass spectrometric detection (LC-HRMS). EEM-PARAFAC showed higher fluorescence intensity for the protein-like component (C2), particularly at CP-VC (near seafood industries) associated with the presence of surfactants (~50 mg/L). SEC-OCD highlighted the WWTP efficiency in removing low molecular weight acids and neutrals. LC-HRMS tentatively identified 108 compounds of emerging concern (CEC) and similar detection patterns were obtained for all wastewater samples, except for PVZ-2 (lower detection), many of which occurred in the effluent. Eight CECs included on relevant Watch-Lists were detected in all WWTPEFF samples. Furthermore, 111 surfactants were detected, the classes more frequently found being alcohol ethoxylates (AEOs), nonylphenol polyethoxylates (NPEOs) and linear alkylbenzene sulphonates (LAS). The continuous presence of LAS and NPEOs allied to surfactants concentrations in the WWTPINF of 15-20 mg/L, with CP-VC location (linked with food industries) as an important contributor, explain the morphological changes in the activated sludge and high LAS content in the dewatered sludge, which may have impacted WWTP performance.
Collapse
Affiliation(s)
- Mariana F T Sá
- Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Verónica Castro
- Department of Analytical Chemistry, Nutrition and Food Sciences, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Ana I Gomes
- Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| | - Daniela F S Morais
- Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Rui V P S Silva Braga
- Efacec Engenharia e Sistemas S.A. (Unidade de Negócios Ambiente), Rua Eng. Frederico Ulrich - Guardeiras, Apartado 3003, 4474-907 Moreira da Maia, Portugal
| | - Isabel Saraiva
- Efacec Engenharia e Sistemas S.A. (Unidade de Negócios Ambiente), Rua Eng. Frederico Ulrich - Guardeiras, Apartado 3003, 4474-907 Moreira da Maia, Portugal
| | - Bianca M Souza-Chaves
- Department of Chemical & Environmental Engineering, University of Arizona, 1133 E James E Rogers Way, Harshbarger 108, Tucson, AZ 85721-0011, USA; CNPq - National Council for Scientific and Technological Development, Brazil
| | - Minkyu Park
- Department of Chemical & Environmental Engineering, University of Arizona, 1133 E James E Rogers Way, Harshbarger 108, Tucson, AZ 85721-0011, USA
| | - Victoria Fernández-Fernández
- Department of Analytical Chemistry, Nutrition and Food Sciences, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Rosario Rodil
- Department of Analytical Chemistry, Nutrition and Food Sciences, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Rosa Montes
- Department of Analytical Chemistry, Nutrition and Food Sciences, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - José Benito Quintana
- Department of Analytical Chemistry, Nutrition and Food Sciences, Institute of Research on Chemical and Biological Analysis (IAQBUS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Vítor J P Vilar
- Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
8
|
Sussman EM, Oktem B, Isayeva IS, Liu J, Wickramasekara S, Chandrasekar V, Nahan K, Shin HY, Zheng J. Chemical Characterization and Non-targeted Analysis of Medical Device Extracts: A Review of Current Approaches, Gaps, and Emerging Practices. ACS Biomater Sci Eng 2022; 8:939-963. [PMID: 35171560 DOI: 10.1021/acsbiomaterials.1c01119] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The developers of medical devices evaluate the biocompatibility of their device prior to FDA's review and subsequent introduction to the market. Chemical characterization, described in ISO 10993-18:2020, can generate information for toxicological risk assessment and is an alternative approach for addressing some biocompatibility end points (e.g., systemic toxicity, genotoxicity, carcinogenicity, reproductive/developmental toxicity) that can reduce the time and cost of testing and the need for animal testing. Additionally, chemical characterization can be used to determine whether modifications to the materials and manufacturing processes alter the chemistry of a patient-contacting device to an extent that could impact device safety. Extractables testing is one approach to chemical characterization that employs combinations of non-targeted analysis, non-targeted screening, and/or targeted analysis to establish the identities and quantities of the various chemical constituents that can be released from a device. Due to the difficulty in obtaining a priori information on all the constituents in finished devices, information generation strategies in the form of analytical chemistry testing are often used. Identified and quantified extractables are then assessed using toxicological risk assessment approaches to determine if reported quantities are sufficiently low to overcome the need for further chemical analysis, biological evaluation of select end points, or risk control. For extractables studies to be useful as a screening tool, comprehensive and reliable non-targeted methods are needed. Although non-targeted methods have been adopted by many laboratories, they are laboratory-specific and require expensive analytical instruments and advanced technical expertise to perform. In this Perspective, we describe the elements of extractables studies and provide an overview of the current practices, identified gaps, and emerging practices that may be adopted on a wider scale in the future. This Perspective is outlined according to the steps of an extractables study: information gathering, extraction, extract sample processing, system selection, qualification, quantification, and identification.
Collapse
Affiliation(s)
- Eric M Sussman
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Berk Oktem
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Irada S Isayeva
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Jinrong Liu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Samanthi Wickramasekara
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Vaishnavi Chandrasekar
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Keaton Nahan
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Hainsworth Y Shin
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Jiwen Zheng
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| |
Collapse
|
9
|
Saint Germain FM, Faure K, Saunier E, Lerestif JM, Heinisch S. On-line 2D-RPLC x RPLC - HRMS to assess wastewater treatment in a pharmaceutical plant. J Pharm Biomed Anal 2022; 208:114465. [PMID: 34826673 DOI: 10.1016/j.jpba.2021.114465] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 10/14/2021] [Accepted: 11/02/2021] [Indexed: 10/19/2022]
Abstract
Pharmaceutical effluents are complex media containing hundreds of compounds including active ingredients, intermediate products and unknown impurities. Bringing an industrial wastewater treatment plant (WWTP) into compliance with European directives requires a thorough analysis of the effluent. In this study, we demonstrate how online comprehensive two-dimensional liquid chromatography (on-line LC × LC) hyphenated to high resolution mass spectrometry (HRMS) can be a powerful analytical methodology to monitoring the outlet water, by analysing the content of known molecules while characterizing unknown compounds. Reversed phase liquid chromatography (RPLC) was used in both dimensions, with a penta-fluoro-phenyl silica-based column at neutral pH in the first dimension (1D) and a C18 column at acidic pH in the second one (2D). The conditions were optimized for a total analysis time of 60 min. The variability of both retention times and peak areas was evaluated. The average standard deviation on retention times was found to be less than 0.1 s in 2D. The relative standard deviation on peak area was about 7% for run-to-run analysis. This analytical approach, applied to the pharmaceutical effluents before (inlet) and after (outlet) wastewater treatment permitted to detect 240 compounds. These included 27 priority pharmaceutical products, 8 of which were of very high priority and their concentrations could be compared to target values. The comparison of 2D-LC and 1D-LC approaches clearly highlights the power of on-line RPLC x RPLC technique, which allows both targeted quantitative analysis and non-targeted qualitative analysis of pharmaceutical effluents.
Collapse
Affiliation(s)
- Fleur Marie Saint Germain
- ORIL Industrie, 13 rue Auguste Desgenetais, 76210 Bolbec, France; Université de Lyon, Institut des Sciences Analytiques, CNRS UMR 5280, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Karine Faure
- Université de Lyon, Institut des Sciences Analytiques, CNRS UMR 5280, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Estelle Saunier
- ORIL Industrie, 13 rue Auguste Desgenetais, 76210 Bolbec, France
| | | | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, CNRS UMR 5280, 5 rue de la Doua, 69100 Villeurbanne, France.
| |
Collapse
|
10
|
Dodds JN, Alexander NLM, Kirkwood KI, Foster MR, Hopkins ZR, Knappe DRU, Baker ES. From Pesticides to Per- and Polyfluoroalkyl Substances: An Evaluation of Recent Targeted and Untargeted Mass Spectrometry Methods for Xenobiotics. Anal Chem 2021; 93:641-656. [PMID: 33136371 PMCID: PMC7855838 DOI: 10.1021/acs.analchem.0c04359] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- James N Dodds
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Nancy Lee M Alexander
- Department of Civil, Construction, & Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27607, United States
| | - Kaylie I Kirkwood
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - MaKayla R Foster
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Zachary R Hopkins
- Department of Civil, Construction, & Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27607, United States
| | - Detlef R U Knappe
- Department of Civil, Construction, & Environmental Engineering, North Carolina State University, Raleigh, North Carolina 27607, United States
| | - Erin S Baker
- Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
11
|
Purschke K, Vosough M, Leonhardt J, Weber M, Schmidt TC. Evaluation of Nontarget Long-Term LC-HRMS Time Series Data Using Multivariate Statistical Approaches. Anal Chem 2020; 92:12273-12281. [PMID: 32812753 DOI: 10.1021/acs.analchem.0c01897] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The use of liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) has steadily increased in many application fields ranging from metabolomics to environmental science. HRMS data are frequently used for nontarget screening (NTS), i.e., the search for compounds that are not previously known and where no reference substances are available. However, the large quantity of data produced by NTS analytical workflows makes data interpretation and time-dependent monitoring of samples very sophisticated and necessitates exploiting chemometric data processing techniques. Consequently, in this study, a prioritization method to handle time series in nontarget data was established. As proof of concept, industrial wastewater was investigated. As routine industrial wastewater analyses monitor the occurrence of a limited number of targeted water contaminants, NTS provides the opportunity to detect also unknown trace organic compounds (TrOCs) that are not in the focus of routine target analysis. The developed prioritization method enables reducing raw data and including identification of prioritized unknown contaminants. To that end, a five-month time series for industrial wastewaters was utilized, analyzed by liquid chromatography-time-of-flight mass spectrometry (LC-qTOF-MS), and evaluated by NTS. Following peak detection, alignment, grouping, and blank subtraction, 3303 features were obtained of wastewater treatment plant (WWTP) influent samples. Subsequently, two complementary ways for exploratory time trend detection and feature prioritization are proposed. Therefore, following a prefiltering step, featurewise principal component analysis (PCA) and groupwise PCA (GPCA) of the matrix (temporal wise) were used to annotate trends of relevant wastewater contaminants. With sparse factorization of data matrices using GPCA, groups of correlated features/mass fragments or adducts were detected, recovered, and prioritized. Similarities and differences in the chemical composition of wastewater samples were observed over time to reveal hidden factors accounting for the structure of the data. The detected features were reduced to 130 relevant time trends related to TrOCs for identification. Exemplarily, as proof of concept, one nontarget pollutant was identified as N-methylpyrrolidone. The developed chemometric strategies of this study are not only suitable for industrial wastewater but also could be efficiently employed for time trend exploration in other scientific fields.
Collapse
Affiliation(s)
- Kirsten Purschke
- Environmental Analysis, Currenta GmbH & Co. OHG, CHEMPARK BLG Q18, D-51368 Leverkusen, Germany.,Instrumental Analytical Chemistry (IAC) and Centre for Water and Environmental Research (ZWU), University of Duisburg-Essen, UnivFersitaetsstrasse 5, D-45141 Essen, Germany
| | - Maryam Vosough
- Department of Clean Technologies, Chemistry and Chemical Engineering Research Centre of Iran (CCERCI), P.O. Box 14335-186 Tehran 14968-13151, Iran
| | - Juri Leonhardt
- Production Analytics, Currenta GmbH & Co. OHG, CHEMPARK BLG B562, D-41538 Dormagen, Germany
| | - Markus Weber
- Environmental Analysis, Currenta GmbH & Co. OHG, CHEMPARK BLG Q18, D-51368 Leverkusen, Germany
| | - Torsten C Schmidt
- Instrumental Analytical Chemistry (IAC) and Centre for Water and Environmental Research (ZWU), University of Duisburg-Essen, UnivFersitaetsstrasse 5, D-45141 Essen, Germany.,IWW Zentrum Wasser, Moritzstrasse 26, 45476 Mülheim an der Ruhr, Germany
| |
Collapse
|
12
|
Zahn D, Neuwald IJ, Knepper TP. Analysis of mobile chemicals in the aquatic environment-current capabilities, limitations and future perspectives. Anal Bioanal Chem 2020; 412:4763-4784. [PMID: 32086538 DOI: 10.1007/s00216-020-02520-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/06/2020] [Accepted: 02/13/2020] [Indexed: 01/08/2023]
Abstract
Persistent and mobile water contaminants are rapidly developing into a focal point of environmental chemistry and chemical regulation. Their defining parameter that sets them apart from the majority of regularly monitored and regulated contaminants is their mobility in the aquatic environment, which is intrinsically tied to a high polarity. This high polarity, however, may have severe implications in the analytical process and thus the most polar of these mobile contaminants may not be covered by widely utilized trace-analytical methods, and thus, alternatives are required. In this review, we infer the physical and chemical properties of mobile water contaminants from a set of almost 1800 prioritized REACH chemicals and discuss the implications these substance properties may have on four integral steps of the analytical process: sampling and sample storage, sample pre-treatment, separation and detection. We discuss alternatives to widely utilized trace-analytical methods, examine their application range and limitations, highlight potential analytical techniques on the horizon and emphasize research areas we believe still offer the most room for further improvement. While we have a comprehensive set of analytical methods to cover a large portion of the known mobile chemicals, these methods are still only infrequently utilized. Graphical abstract.
Collapse
Affiliation(s)
- Daniel Zahn
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany.
| | - Isabelle J Neuwald
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany
| | - Thomas P Knepper
- Hochschule Fresenius gem. GmbH, Limburger Str. 2, 65510, Idstein, Germany
| |
Collapse
|