Braun V, Ceglarek U, Gaudl A, Gawinecka J, Müller D, Rauh M, Weber M, Seger C. Evaluation of five multisteroid LC‒MS/MS methods used for routine clinical analysis: comparable performance was obtained for nine analytes. Clin Chem Lab Med 2024; 62:900-910. [PMID: 38038605 DOI: 10.1515/cclm-2023-0847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 11/03/2023] [Indexed: 12/02/2023]
Abstract
OBJECTIVES A mass spectrometry (LC‒MS/MS)-based interlaboratory comparison study was performed for nine steroid analytes with five participating laboratories. The sample set contained 40 pooled samples of human serum generated from preanalyzed leftovers. To obtain a well-balanced distribution across reference intervals of each steroid, the leftovers first underwent a targeted mixing step. METHODS All participants measured a sample set once using their own multianalyte protocols and calibrators. Four participants used in-house developed measurement platforms, including IVD-CE certified calibrators, which were used by three participants; the 5th lab used the whole LC‒MS kit from an IVD manufacturer. All labs reported results for 17-hydroxyprogesterone, androstenedione, cortisol, and testosterone, and four labs reported results for 11-deoxycortisol, corticosterone, cortisone, dehydroepiandrosterone sulfate (DHEAS), and progesterone. RESULTS Good or acceptable overall comparability was found in Bland‒Altman and Passing‒Bablok analyses. Mean bias against the overall mean remained less than ±10 % except for DHEAS, androstenedione, and progesterone at one site and for cortisol and corticosterone at two sites (max. -18.9 % for androstenedione). The main analytical problems unraveled by this study included a bias not previously identified in proficiency testing, operator errors, non-supported matrix types and higher inaccuracy and imprecision at lower ends of measuring intervals. CONCLUSIONS This study shows that intermethod comparison is essential for monitoring the validity of an assay and should serve as an example of how external quality assessment could work in addition to organized proficiency testing schemes.
Collapse
Affiliation(s)
- Valentin Braun
- Institute of Pharmacy/Pharmacognosy, CCB - Centrum of Chemistry and Biomedicine, University of Innsbruck, Innsbruck, Austria
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| | - Uta Ceglarek
- Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, Leipzig University, Leipzig, Germany
| | - Alexander Gaudl
- Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, Leipzig University, Leipzig, Germany
| | - Joanna Gawinecka
- Institute of Clinical Chemistry, University Hospital Zurich, Zürich, Switzerland
| | - Daniel Müller
- Institute of Clinical Chemistry, University Hospital Zurich, Zürich, Switzerland
- Department of Clinical Chemistry and Laboratory Medicine, University Hospital Basel, Basel, Switzerland
| | - Manfred Rauh
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Erlangen, Germany
| | | | - Christoph Seger
- Institute of Pharmacy/Pharmacognosy, CCB - Centrum of Chemistry and Biomedicine, University of Innsbruck, Innsbruck, Austria
- Dr. Risch Ostschweiz AG, Buchs, Switzerland
| |
Collapse
|
2
|
Watz ME, Tivesten Å, Ottarsdottir K, Li Y, Hellgren MI, Lindblad U, Daka B. Reply on: Analyzing the effects of sex hormone-binding globulin levels and development of hypertension in middle-aged men and women. J Hypertens 2024; 42:580-581. [PMID: 38290001 PMCID: PMC10842648 DOI: 10.1097/hjh.0000000000003630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Affiliation(s)
- Michel E.S. Watz
- Family Medicine, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg
| | - Åsa Tivesten
- Wallenberg Laboratory for Cardiovascular and Metabolic Research, Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg
- Department of Endocrinology, Sahlgrenska University Hospital, Region Västra Götaland
| | - Kristin Ottarsdottir
- Family Medicine, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg
| | - Ying Li
- Biostatistics, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Margareta I. Hellgren
- Family Medicine, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg
| | - Ulf Lindblad
- Family Medicine, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg
| | - Bledar Daka
- Family Medicine, School of Public Health and Community Medicine, Institute for Medicine, Sahlgrenska Academy, University of Gothenburg
| |
Collapse
|
3
|
Tim Cao Z, Rej R, Vesper H, Rex Astles J. Accuracy-based proficiency testing for estradiol measurements. Clin Biochem 2024; 124:110700. [PMID: 38043696 PMCID: PMC11261451 DOI: 10.1016/j.clinbiochem.2023.110700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 11/26/2023] [Accepted: 11/30/2023] [Indexed: 12/05/2023]
Abstract
OBJECTIVES Accuracy of estradiol measurements is important but conventional proficiency testing (PT) cannot assess accuracy when possibly non-commutable samples are used and method peer-group means are the targets. Accuracy-based assessment of estradiol measurements is needed. DESIGN AND METHODS Five serum samples were prepared from single donors, frozen, and distributed overnight to 76 New York State Department of Health (NYSDOH)-certified laboratories. Participants analyzed samples for estradiol. The biases of group means were assessed against the Centers for Disease Control and Prevention (CDC)-defined targets, evaluated using the Hormone Standardization Program (HoSt) E2 performance criterion of ±12.5 %. Each laboratory's performance was evaluated using total allowable error (acceptance limits) of target ±25 % or ±15 pg/mL (55 pmol/L) (whichever was greater, NYSDOH), target ±30 % (Clinical Laboratory Improvement Amendments [CLIA]), and target ±26 % (minimal limit based on biological variation [BV]). RESULTS The biases (range) were 34 % (-17 % to 175 %), 40 % (-33 % to 386 %), 16 % (-45 % to 193 %), 5 % (-27 % to 117 %), and -4% (-31 % to 21 %), for samples at estradiol of 24.1, 28.4, 61.7, 94.1, and 127 pg/mL, or 89, 104, 227, 345, and 466 pmol/L, respectively. Large positive method/analytical systematic biases were revealed for 9 commonly used method/analytical systems in the United States at low estradiol concentrations. Of the 9 analytical systems, 0, 0, 3, 7 and 6 met the HoSt criterion for the samples with estradiol at the five respective concentrations. PT evaluation showed that 59 %, 69 % and 87 % of laboratories would receive a PT event passing (satisfactory) score when the CDC-defined target and a criterion of NYSDOH, CLIA or BV was used, respectively. However, >95 % laboratories would obtain PT passing score if method peer-group means were used as targets regardless of the criterion used. CONCLUSIONS Improvement in accuracy of estradiol measurements is needed, particularly at low estradiol concentrations. Accuracy-based PT provides unambiguous information about the accuracy of methods/analytical systems.
Collapse
Affiliation(s)
- Zhimin Tim Cao
- Wadsworth Center, New York State Department of Health, Albany, NY, United States; Department of Pathology, SUNY Upstate Medical University, Syracuse, NY, United States
| | - Robert Rej
- Wadsworth Center, New York State Department of Health, Albany, NY, United States; Department of Biomedical Sciences, School of Public Health, University at Albany, State University of New York, Albany, NY, United States
| | - Hubert Vesper
- Centers for Disease Control and Prevention, Atlanta, GA, United States
| | - J Rex Astles
- Centers for Disease Control and Prevention, Atlanta, GA, United States.
| |
Collapse
|
4
|
Lorde N, Elgharably A, Kalaria T. Impact of Variation between Assays and Reference Intervals in the Diagnosis of Endocrine Disorders. Diagnostics (Basel) 2023; 13:3453. [PMID: 37998589 PMCID: PMC10670091 DOI: 10.3390/diagnostics13223453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/10/2023] [Accepted: 11/13/2023] [Indexed: 11/25/2023] Open
Abstract
Method-related variations in the measurement of hormones and the reference intervals used in the clinical laboratory can have a significant, but often under-appreciated, impact on the diagnosis and management of endocrine disorders. This variation in laboratory practice has the potential to lead to an errant approach to patient care and thus could cause harm. It may also be the source of confusion or result in excessive or inadequate investigation. It is important that laboratory professionals and clinicians know about these impacts, their sources, and how to detect and mitigate them when they do arise. In this review article, we describe the historical and scientific context from which inconsistency in the clinical laboratory arises. Examples from the published literature of the impact of the method, reference interval, and clinical decision threshold-related discordances on the assessment and monitoring of various endocrine disorders are discussed to illustrate the sources, causes, and effects of this variability. Its potential impact on the evaluation of growth hormone deficiency and excess, thyroid and parathyroid disorders, hyperandrogenism, hypogonadism, glucocorticoid excess and deficiency, and diabetes mellitus is elaborated. Strategies for assessment and mitigation of the discordance are discussed. The clinical laboratory has a responsibility to recognise and address these issues, and although a lot has been accomplished in this area already, there remains more to be done.
Collapse
Affiliation(s)
- Nathan Lorde
- Black Country Pathology Services, The Royal Wolverhampton NHS Trust, Wolverhampton WV10 0QP, UK; (A.E.); (T.K.)
| | | | | |
Collapse
|
5
|
Not within spitting distance: Salivary immunoassays of estradiol have subpar validity for predicting cycle phase. Psychoneuroendocrinology 2023; 149:105994. [PMID: 36527751 DOI: 10.1016/j.psyneuen.2022.105994] [Citation(s) in RCA: 17] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 11/26/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022]
Abstract
Salivary steroid immunoassays are widely used in psychoneuroendocrinological studies of menstrual cycle phase, puberty, and menopause. Though manufacturers advertise their assays as suitable, they have not been rigorously validated for these purposes. We collated data from eight menstrual cycle studies across > 1200 female participants and > 9500 time points. Seven studies collected saliva and one collected serum. All assayed estradiol and progesterone and had an independent measure of cycle phase (LH-surge, menstrual onset). In serum, cycle phase measures strongly predicted steroid concentrations. In saliva, cycle phase poorly predicted estradiol values, which showed an upward bias compared to expectations from serum. For salivary progesterone, predictability from cycle phase was mixed, low for enzyme-linked assays and moderate for tandem mass spectrometry. Imputing the population-average serum steroid changes from cycle phase may yield more valid values of hormonal changes for an independent person than directly assessing their hormone levels using salivary immunoassays.
Collapse
|
6
|
Liu SC, Suresh M, Jaber M, Mercado Munoz Y, Sarafoglou K. Case Report: Anastrozole as a monotherapy for pre-pubertal children with non-classic congenital adrenal hyperplasia. Front Endocrinol (Lausanne) 2023; 14:1101843. [PMID: 36936152 PMCID: PMC10018749 DOI: 10.3389/fendo.2023.1101843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 02/17/2023] [Indexed: 03/06/2023] Open
Abstract
Most children with non-classic congenital adrenal hyperplasia (NC-CAH) due to 21-hydroxylase deficiency are asymptomatic and do not require cortisol replacement therapy unless they develop symptoms of hyperandrogenemia. The current practice is to treat symptomatic children with hydrocortisone aimed at suppressing excess adrenal androgen production irrespective of the child's level of endogenous cortisol production. Once on hydrocortisone therapy, even children with normal cortisol production require stress dosing. Some children with NC-CAH may present with premature adrenarche, growth acceleration, and advanced bone age, but with no signs of genital virilization and normal endogenous cortisol production. In these cases, an alternative therapy to hydrocortisone treatment that does not impact the hypothalamic-pituitary-adrenal axis, but targets increased estrogen production and its effects on bone maturation, could be considered. Aromatase inhibitors (AIs), which block the aromatization of androgen to estrogen, have been used off-label in men with short stature to delay bone maturation and as an adjunct therapy in children with classic CAH. The use of AI as a monotherapy for children with NC-CAH has never been reported. We present three pre-pubertal female children with a diagnosis of NC-CAH treated with anastrozole monotherapy after presenting with advanced bone age, early adrenarche, no signs of genital virilization, and normal peak cortisol in response to ACTH stimulation testing. Bone age z-scores normalized, and all three reached or exceeded their target heights. Monotherapy with anastrozole can be an effective alternative in slowing down bone maturation and improving height outcomes in children with NC-CAH and normal adrenal cortisol production.
Collapse
Affiliation(s)
- Sandy C. Liu
- Department of Pediatrics, Division of Pediatric Endocrinology, University of Minnesota Medical School, Minneapolis, MN, United States
| | - Malavika Suresh
- Department of Pediatrics, Division of Pediatric Endocrinology, University of Minnesota Medical School, Minneapolis, MN, United States
| | - Mutaz Jaber
- Department of Experimental and Clinical Pharmacology, University of Minnesota College of Pharmacy, Minneapolis, MN, United States
| | - Yesica Mercado Munoz
- Department of Pediatrics, Division of Pediatric Endocrinology, University of Minnesota Medical School, Minneapolis, MN, United States
| | - Kyriakie Sarafoglou
- Department of Pediatrics, Division of Pediatric Endocrinology, University of Minnesota Medical School, Minneapolis, MN, United States
- Department of Experimental and Clinical Pharmacology, University of Minnesota College of Pharmacy, Minneapolis, MN, United States
- *Correspondence: Kyriakie Sarafoglou,
| |
Collapse
|
7
|
Fanelli F, Cantù M, Temchenko A, Mezzullo M, Lindner JM, Peitzsch M, Hawley JM, Bruce S, Binz PA, Ackermans MT, Heijboer AC, Van den Ouweland J, Koeppl D, Nardi E, MacKenzie F, Rauh M, Eisenhofer G, Keevil BG, Vogeser M, Pagotto U. Report from the HarmoSter study: impact of calibration on comparability of LC-MS/MS measurement of circulating cortisol, 17OH-progesterone and aldosterone. Clin Chem Lab Med 2022; 60:726-739. [PMID: 35172417 DOI: 10.1515/cclm-2021-1028] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 01/31/2022] [Indexed: 01/24/2023]
Abstract
OBJECTIVES Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention. The aim of the study was to compare LC-MS/MS measurements of cortisol, 17OH-progesterone and aldosterone from nine European centers and assess performance according to external quality assessment (EQA) materials and calibration. METHODS Seventy-eight patient samples, EQA materials and two commercial calibration sets were measured twice by laboratory-specific procedures. Results were obtained by in-house (CAL1) and external calibrations (CAL2 and CAL3). We evaluated intra and inter-laboratory imprecision, correlation and agreement in patient samples, and trueness, bias and commutability in EQA materials. RESULTS Using CAL1, intra-laboratory CVs ranged between 2.8-7.4%, 4.4-18.0% and 5.2-22.2%, for cortisol, 17OH-progesterone and aldosterone, respectively. Trueness and bias in EQA materials were mostly acceptable, however, inappropriate commutability and target value assignment were highlighted in some cases. CAL2 showed suboptimal accuracy. Median inter-laboratory CVs for cortisol, 17OH-progesterone and aldosterone were 4.9, 11.8 and 13.8% with CAL1 and 3.6, 10.3 and 8.6% with CAL3 (all p<0.001), respectively. Using CAL1, median bias vs. all laboratory-medians ranged from -6.6 to 6.9%, -17.2 to 7.8% and -12.0 to 16.8% for cortisol, 17OH-progesterone and aldosterone, respectively. Regression lines significantly deviated from the best fit for most laboratories. Using CAL3 improved cortisol and 17OH-progesterone between-method bias and correlation. CONCLUSIONS Intra-laboratory imprecision and performance with EQA materials were variable. Inter-laboratory performance was mostly within specifications. Although residual variability persists, adopting common traceable calibrators and RMP-determined EQA materials is beneficial for standardization of LC-MS/MS steroid measurements.
Collapse
Affiliation(s)
- Flaminia Fanelli
- Department of Medical and Surgical Sciences, Unit of Endocrinology and Prevention and Care of Diabetes, Center for Applied Biomedical Research, University of Bologna, S. Orsola Policlinic, Bologna, Italy
| | - Marco Cantù
- Laboratory of Clinical Biochemistry and Pharmacology, Institute of Laboratory Medicine EOLAB, Ente Ospedaliero Cantonale, Bellinzona, Switzerland
| | - Anastasia Temchenko
- Department of Medical and Surgical Sciences, Unit of Endocrinology and Prevention and Care of Diabetes, Center for Applied Biomedical Research, University of Bologna, S. Orsola Policlinic, Bologna, Italy
| | - Marco Mezzullo
- Department of Medical and Surgical Sciences, Unit of Endocrinology and Prevention and Care of Diabetes, Center for Applied Biomedical Research, University of Bologna, S. Orsola Policlinic, Bologna, Italy
| | - Johanna M Lindner
- Institute of Laboratory Medicine, Hospital of the University of Munich (LMU), Munich, Germany
| | - Mirko Peitzsch
- Institute of Clinical Chemistry and Laboratory Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - James M Hawley
- Department of Clinical Biochemistry, University Hospital South Manchester, Manchester NHS Foundation Trust, Manchester, UK
| | - Stephen Bruce
- Clinical Chemistry Laboratory, University Hospital of Lausanne (CHUV), Lausanne, Switzerland
| | - Pierre-Alain Binz
- Clinical Chemistry Laboratory, University Hospital of Lausanne (CHUV), Lausanne, Switzerland
| | - Mariette T Ackermans
- Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Annemieke C Heijboer
- Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Jody Van den Ouweland
- Department of Clinical Chemistry, Canisius-Wilhelmina Hospital, Nijmegen, The Netherlands
| | - Daniel Koeppl
- Department of Pediatrics and Adolescent Medicine, University Hospital, Erlangen, Germany
| | - Elena Nardi
- Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy
| | - Finlay MacKenzie
- University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
| | - Manfred Rauh
- Department of Pediatrics and Adolescent Medicine, University Hospital, Erlangen, Germany
| | - Graeme Eisenhofer
- Institute of Clinical Chemistry and Laboratory Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Brian G Keevil
- Department of Clinical Biochemistry, University Hospital South Manchester, Manchester NHS Foundation Trust, Manchester, UK
| | - Michael Vogeser
- Institute of Laboratory Medicine, Hospital of the University of Munich (LMU), Munich, Germany
| | - Uberto Pagotto
- Department of Medical and Surgical Sciences, Unit of Endocrinology and Prevention and Care of Diabetes, Center for Applied Biomedical Research, University of Bologna, S. Orsola Policlinic, Bologna, Italy
| |
Collapse
|
8
|
Cirrincione LR, Crews BO, Dickerson JA, Krasowski MD, Rongitsch J, Imborek KL, Goldstein Z, Greene DN. Oral estrogen leads to falsely low concentrations of estradiol in a common immunoassay. Endocr Connect 2022; 11:e210550. [PMID: 35015702 PMCID: PMC8859944 DOI: 10.1530/ec-21-0550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 01/11/2022] [Indexed: 11/30/2022]
Abstract
Objectives Recently, an estradiol immunoassay manufacturer (Beckman Coulter, USA) issued an 'important product notice' alerting clinical laboratories that their assay (Access Sensitive Estradiol) was not indicated for patients undergoing exogenous estradiol treatment. The objective of this analysis was to evaluate immunoassay bias relative to liquid chromatography tandem mass spectrometry (LC-MS/MS) in transgender women and to examine the influence of unconjugated estrone on measurements. Design Cross-sectional secondary analysis. Methods Estradiol concentrations from 89 transgender women were determined by 3 immunoassays (Access Sensitive Estradiol ('New BC') and Access Estradiol assays ('Old BC'), Beckman Coulter; Estradiol III assay ('Roche'), Roche Diagnostics) and LC-MS/MS. Bias was evaluated with and without adjustment for estrone concentrations. The number of participants who shifted between three estradiol concentration ranges for each immunoassay vs LC-MS/MS (>300 pg/mL, 70-300 pg/mL, and <70 pg/mL) was calculated. Results The New BC assay had the largest magnitude overall bias (median: -34%) and was -40%, -22%, and -10%, among participants receiving tablet, patch, or injection preparations, respectively. Overall bias was -12% and +17% for the Roche and Old BC assays, respectively. When measured with the New BC assay, 18 participants shifted to a lower estradiol concentration range (vs 9 and 10 participants based on Roche or Old BC assays, respectively). Adjustment for estrone did not minimize bias. Conclusions Immunoassay measurement of estradiol in transgender women may lead to falsely decreased concentrations that have the potential to affect management. A multidisciplinary health care approach is needed to ensure if appropriate analytical methods are available.
Collapse
Affiliation(s)
| | - Bridgit O Crews
- Department of Pathology and Laboratory Medicine, University of California Irvine, Orange, California, USA
| | - Jane A Dickerson
- Department of Laboratories, Seattle Children's Hospital, Seattle, Washington, USA
| | - Matthew D Krasowski
- Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
| | | | - Katherine L Imborek
- Department of Family Medicine, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA
| | - Zil Goldstein
- Department of Medicine, Callen-Lorde Community Health Center, New York, New York, USA
- CUNY Graduate School of Public Health and Health Policy, New York, New York, USA
| | - Dina N Greene
- Washington Kaiser Permanente, Renton, Washington, USA
- Department of Laboratory Medicine and Pathology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
9
|
Голодников ИИ, Павлова ЗШ, Камалов АА. [Testosterone replacement therapy and its relationship with hyperestrogenism and obesity. Problems of laboratory diagnostics of hyperestrogenism]. PROBLEMY ENDOKRINOLOGII 2021; 68:101-108. [PMID: 35262301 PMCID: PMC9761874 DOI: 10.14341/probl12742] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 11/30/2021] [Accepted: 11/30/2021] [Indexed: 01/09/2023]
Abstract
Testosterone replacement therapy (TRT) is one of the most effective and common treatments for testosterone deficiency today. It is often prescribed, focusing only on the level of testosterone and the presence of patient complaints about a decrease in sexual function. Quite rarely, doctors additionally assess the level of estradiol and, as a consequence, the initial presence of a symptom of hyperestrogenism. One of the likely consequences of the appointment of TRT may be an excess of estradiol, the excess formation of which is associated with the enzyme aromatase, which converts testosterone into estradiol. Despite the availability of laboratory determination of the level of estradiol, the result may not always coincide with the clinical picture, one of the reasons is the difference in the methods for determining the level of estradiol in each laboratory, there is no single standard or «reference» today. This article describes the evolution of TRT, and also focuses on the variability of estradiol levels from laboratory to laboratory, and explains in detail why the assessment of estradiol over time should be carried out in only one laboratory. A systematic literature search was carried out in the databases Medline, Scopus, Web of Science and Elibrary, CyberLeninka.The purpose of our review was the need to engage the attention of specialists to the problem of hyperestrogenism, the not always justified prescription of TRT in patients with obesity, hypogonadism and hyperestrogenism, as well as to the problem of laboratory diagnosis of hyperestrogenism, which is acute not only in our country, but all over the world.
Collapse
Affiliation(s)
- И. И. Голодников
- Российская медицинская академия непрерывного профессионального образования Минздрава России
| | - З. Ш. Павлова
- Медицинский научно-образовательный центр МГУ им. М.В. Ломоносова
| | - А. А. Камалов
- Медицинский научно-образовательный центр МГУ им. М.В. Ломоносова
| |
Collapse
|
10
|
Gravitte A, Archibald T, Cobble A, Kennard B, Brown S. Liquid chromatography-mass spectrometry applications for quantification of endogenous sex hormones. Biomed Chromatogr 2020; 35:e5036. [PMID: 33226656 DOI: 10.1002/bmc.5036] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 11/20/2020] [Accepted: 11/20/2020] [Indexed: 01/18/2023]
Abstract
Liquid chromatography, coupled with tandem mass spectrometry, presents a powerful tool for the quantification of the sex steroid hormones 17-β estradiol, progesterone and testosterone from biological matrices. The importance of accurate quantification with these hormones, even at endogenous levels, has evolved with our understanding of the role these regulators play in human development, fertility and disease risk and manifestation. Routine monitoring of these analytes can be accomplished by immunoassay techniques, which face limitations on specificity and sensitivity, or using gas chromatography-mass spectrometry. LC-MS/MS is growing in capability and acceptance for clinically relevant quantification of sex steroid hormones in biological matrices and is able to overcome many of the limitations of immunoassays. Analyte specificity has improved through the use of novel derivatizing agents, and sensitivity has been refined through the use of high-resolution chromatography and mass spectrometric technology. This review highlights these innovations, among others, in LC-MS/MS steroid hormone analysis captured in the literature over the last decade.
Collapse
Affiliation(s)
- Amy Gravitte
- James H Quillen College of Medicine, East Tennessee State University, Department of Biomedical Sciences, Johnson City, TN, USA
| | - Timothy Archibald
- Bill Gatton College of Pharmacy, East Tennessee State University, Department of Pharmaceutical Sciences, Johnson City, TN, USA
| | - Allison Cobble
- Bill Gatton College of Pharmacy, East Tennessee State University, Department of Pharmaceutical Sciences, Johnson City, TN, USA
| | - Benjamin Kennard
- Bill Gatton College of Pharmacy, East Tennessee State University, Department of Pharmaceutical Sciences, Johnson City, TN, USA
| | - Stacy Brown
- Bill Gatton College of Pharmacy, East Tennessee State University, Department of Pharmaceutical Sciences, Johnson City, TN, USA
| |
Collapse
|
11
|
After another decade: LC-MS/MS became routine in clinical diagnostics. Clin Biochem 2020; 82:2-11. [PMID: 32188572 DOI: 10.1016/j.clinbiochem.2020.03.004] [Citation(s) in RCA: 152] [Impact Index Per Article: 38.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 03/09/2020] [Accepted: 03/12/2020] [Indexed: 01/01/2023]
Abstract
Tandem mass spectrometry - especially in combination with liquid chromatography (LC-MS/MS) - is applied in a multitude of important diagnostic niches of laboratory medicine. It is unquestioned in its routine use and is often unreplaceable by alternative technologies. This overview illustrates the development in the past decade (2009-2019) and intends to provide insight into the current standing and future directions of the field. The instrumentation matured significantly, the applications are well understood, and the in vitro diagnostics (IVD) industry is shaping the market by providing assay kits, certified instruments, and the first laboratory automated LC-MS/MS instruments as an analytical core. In many settings the application of LC-MS/MS is still burdensome with locally lab developed test (LDT) designs relying on highly specialized staff. The current routine applications cover a wide range of analytes in therapeutic drug monitoring, endocrinology including newborn screening, and toxicology. The tasks that remain to be mastered are, for example, the quantification of proteins by means of LC-MS/MS and the transition from targeted to untargeted omics approaches relying on pattern recognition/pattern discrimination as a key technology for the establishment of diagnostic decisions.
Collapse
|
12
|
Mezzullo M, Pelusi C, Fazzini A, Repaci A, Di Dalmazi G, Gambineri A, Pagotto U, Fanelli F. Female and male serum reference intervals for challenging sex and precursor steroids by liquid chromatography - tandem mass spectrometry. J Steroid Biochem Mol Biol 2020; 197:105538. [PMID: 31734493 DOI: 10.1016/j.jsbmb.2019.105538] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 10/29/2019] [Accepted: 11/11/2019] [Indexed: 02/03/2023]
Abstract
Measuring some sex and precursor steroids is still challenging even by liquid chromatography - tandem mass spectrometry (LC-MS/MS), and few normal values are available. We developed a LC-MS/MS method for estradiol, estrone, dihydrotestosterone and 17-hydroxypregnenolone measurement, compared it with direct immunoassays, and generated sex, age, menopausal and menstrual status specific reference intervals. Liquid-liquid extraction was optimized on 300 μL serum spiked with isotopic internal standards. A 2D-LC system allowed on-line purification and separation in 11 min run. Electrospray ionization was enhanced by ammonium fluoride. MS-detection was obtained by multiple reaction monitoring. Direct ECLIA for estradiol (n = 80) and RIA for estrone (n = 41) were compared with LC-MS/MS. Reference values were estimated in healthy, lean women in reproductive age (n = 118), menopausal women (n = 33) and men (n = 159). The assay showed satisfying imprecision, trueness, recovery and selectivity. Adequate functional sensitivity was achieved for measuring estrone (18.1 pmol/L) and 17-hydroxypregnenolone (117 pmol/L) in all subjects, and estradiol (35.9 pmol/L) and dihydrotestosterone (134 pmol/L) in women in reproductive age and men, but not in menopausal women. Compared with LC-MS/MS, immunoassays showed good agreement for estradiol but severe disagreement for estrone. Estrogens exhibited sex, menopausal and menstrual variations. Dihydrotestosterone and 17-hydroxypregnenolone depended on sex and menopause, the latter also declining with age in men. Strictly defined reference intervals in the adult female and male population were generated for challenging steroids such as estrogens, dihydrotestosterone and 17-hydroxypregnenolone by a novel LC-MS/MS method. Our achievement can be used to deepen the comprehension of several endocrine diseases.
Collapse
Affiliation(s)
- Marco Mezzullo
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Carla Pelusi
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Alessia Fazzini
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Andrea Repaci
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Guido Di Dalmazi
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Alessandra Gambineri
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Uberto Pagotto
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| | - Flaminia Fanelli
- Endocrinology Unit and Center for Applied Biomedical Research, Department of Medical and Surgical Sciences, University of Bologna, S.Orsola Policlinic, via Massarenti 9, 40138 Bologna, Italy.
| |
Collapse
|
13
|
Macias-Muñoz L, Filella X, Augé JM, Hanzu FA, Morales-Ruiz M, Bedini JL, Jiménez W, Casals G. Performance evaluation of Siemens Atellica enhanced estradiol assay. ADVANCES IN LABORATORY MEDICINE 2020; 1:20190009. [PMID: 37362558 PMCID: PMC10197438 DOI: 10.1515/almed-2019-0009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 10/24/2019] [Indexed: 06/28/2023]
Abstract
Background Serum estradiol (E2) levels may be used in the diagnostic and/or monitoring of a broad variety of clinical conditions. The aims of this study were to evaluate the Siemens enhanced estradiol assay (eE2) on Atellica IM 1600 (Siemens Healthineers) and to perform a sample comparison with the Siemens ADVIA Centaur XP (Siemens Healthineers). Methods Within-day and between-day coefficient of variation (CV) were determined using serum sample pools and quality control materials. Six serum samples with decreasing concentrations of E2 were used to assess the limit of quantification. Linearity was evaluated using two different serum samples. Accuracy was evaluated by measuring three certified reference materials. Passing-Bablok regression and Bland-Altman plot were used for comparing Atellica and Centaur XP in 119 serum samples ranging from 45 to 10,059 pmol/L. Results Within-day and between-day imprecision was <6.6%. Accuracy was <6.0% for all values except for 114 pmol/L (22%). The study of limit of quantification resulted in an interday imprecision <20%. High correlation between measured and expected estradiol dilution results was observed (R = 0.99), with recoveries ranging from 77 to 93%. Comparison study showed good agreement and no significant bias. Conclusions The study shows that Atellica eE2 assay presents acceptable imprecision and accuracy and correlates well with Centaur XP.
Collapse
Affiliation(s)
- Laura Macias-Muñoz
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
| | - Xavier Filella
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
| | - Josep Maria Augé
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
| | - Felicia A. Hanzu
- Department of Endocrinology, Hospital Clínic, IDIBAPS, Barcelona, Spain
- University of Barcelona, Barcelona, Spain
| | - Manuel Morales-Ruiz
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
- University of Barcelona, Barcelona, Spain
| | - Josep Lluis Bedini
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
| | - Wladimiro Jiménez
- Department of Biochemistry and Molecular Genetics, Hospital Clínic, IDIBAPS, Barcelona, Spain
- University of Barcelona, Barcelona, Spain
| | - Gregori Casals
- Department of Biochemistry and Molecular Genetics, Hospital Clinic Universitari, Villarroel 170, Barcelona 08036, Spain
| |
Collapse
|
14
|
Zhang Q, Cai Z, Liu Y, Lin H, Wang Q, Yan J, Han L, Wang J, Ke P, Zhuang J, Huang X. Comparison of bracketing calibration and classical calibration curve quantification methods in establishing a candidate reference measurement procedure for human serum 17β-estradiol by isotope dilution liquid chromatography tandem mass spectrometry. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104270] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
15
|
Dowis J, Woroniecki W, French D. Development and validation of a LC-MS/MS assay for quantification of serum estradiol using calibrators with values assigned by the CDC reference measurement procedure. Clin Chim Acta 2019; 492:45-49. [DOI: 10.1016/j.cca.2019.02.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 01/31/2019] [Accepted: 02/02/2019] [Indexed: 12/11/2022]
|
16
|
Santi D, De Vincentis S, Scaltriti S, Rochira V. Relative hyperestrogenism in Klinefelter Syndrome: results from a meta-analysis. Endocrine 2019; 64:209-219. [PMID: 30701446 DOI: 10.1007/s12020-019-01850-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 01/18/2019] [Indexed: 11/24/2022]
Abstract
OBJECTIVE Klinefelter Syndrome (KS) is classically described as characterized by hyperestrogenism, although solid evidence is lacking. This study aims to test the hypothesis that men with KS have higher serum estradiol than normal controls. DESIGN Meta-analysis of all studies extracted by MEDLINE from 1942 to 31 January 2018. All studies reporting serum estradiol measurement were considered, among them only case-control studies were included in the meta-analysis. METHODS Meta-analysis was conducted according to the PRISMA statement using RevMan. RESULTS Out of 4120 articles, 23 case-control studies, 14 case series, and 19 case reports reported data on serum estradiol. A total of 707 KS and 1019 controls were included in the meta-analysis. Serum estradiol was slightly, but significantly higher in KS than controls (mean difference 4.25 pg/mL; CI: 0.41, 8.10 pg/mL; p = 0.030). This difference was lost considering only studies using estradiol assays with good accuracy (5.48 pg/mL, CI: -2.11, 13.07 pg/mL; p = 0.160). Serum testosterone and estradiol/testosterone ratio were significantly lower and higher in KS than controls, respectively. Data from KS case series and case reports confirmed that serum estradiol is within the normal ranges. CONCLUSIONS Serum estradiol is not increased in KS although slightly higher than controls. However, the meta-analysis that included only studies using a serum estradiol assay with good accuracy showed no difference in serum estradiol between KS and controls. The traditional belief that KS is associated with elevated serum estradiol should be reconsidered. This meta-analysis shows that men with KS have relative hyperestrogenism (increased estradiol/testosterone ratio) compared to controls.
Collapse
Affiliation(s)
- Daniele Santi
- Unit of Endocrinology, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
- Department of Medical Specialties, Azienda Ospedaliero-Universitaria di Modena, Ospedale Civile di Baggiovara, Modena, Italy
| | - Sara De Vincentis
- Unit of Endocrinology, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Sara Scaltriti
- Unit of Endocrinology, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Vincenzo Rochira
- Unit of Endocrinology, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy.
- Department of Medical Specialties, Azienda Ospedaliero-Universitaria di Modena, Ospedale Civile di Baggiovara, Modena, Italy.
| |
Collapse
|
17
|
Estradiol reference intervals in women during the menstrual cycle, postmenopausal women and men using an LC-MS/MS method. Clin Chim Acta 2019; 495:198-204. [PMID: 30981845 DOI: 10.1016/j.cca.2019.04.062] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 04/09/2019] [Accepted: 04/10/2019] [Indexed: 11/20/2022]
Abstract
BACKGROUND For optimal medical decision-making, harmonized reference intervals for estradiol for different ages and both sexes are needed. Our aim was to establish reference intervals using a highly accurate and traceable LC-MS/MS method and to compare these with reference intervals in literature. METHODS Estradiol was measured in serum obtained daily during the menstrual cycle of 30 healthy premenopausal women and in serum of 64 men and 33 postmenopausal women. The accuracy of our LC-MS/MS method was demonstrated by a method comparison with the CDC reference method. RESULTS Our LC-MS/MS method was traceable to the reference method. Estradiol reference interval during the early follicular phase (days -15 to -6) was 31-771 pmol/L; during the late follicular phase (days -5 to -1) 104-1742 pmol/L; during the LH peak (day 0) 275-2864 pmol/L; during the early luteal phase (days +1 to +4) 95-1188 pmol/L; during mid luteal phase (days +5 to +9) 151-1941 pmol/L; during late luteal phase (days +10 to +14) 39-1769 pmol/L. The reference interval for men was 12-136 pmol/L and for postmenopausal women <26 pmol/L. CONCLUSIONS The established estradiol reference intervals can be used for all traceable LC-MS/MS methods for medical-decision making.
Collapse
|
18
|
Drotleff B, Hallschmid M, Lämmerhofer M. Quantification of steroid hormones in plasma using a surrogate calibrant approach and UHPLC-ESI-QTOF-MS/MS with SWATH-acquisition combined with untargeted profiling. Anal Chim Acta 2018; 1022:70-80. [DOI: 10.1016/j.aca.2018.03.040] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 03/16/2018] [Accepted: 03/20/2018] [Indexed: 11/16/2022]
|
19
|
Zhou H, Wang Y, Gatcombe M, Farris J, Botelho JC, Caudill SP, Vesper HW. Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2017; 409:5943-5954. [PMID: 28801832 DOI: 10.1007/s00216-017-0529-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 07/05/2017] [Accepted: 07/18/2017] [Indexed: 12/13/2022]
Abstract
Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone-related disorders in patient care and translational research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03-48.5 nM (0.75-1400 ng/dL) and estradiol 11.0-5138 pM (2.99-1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and -0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for 2 years with mean bias -0.7% (95% CI -1.6% to 0.2%) for testosterone and 0.1% (95% CI -2.2% to 2.3%) for estradiol. The method precision over a 2-year period for quality control pools at low, medium, and high concentrations was 2.7-2.9% for testosterone and 3.3-5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies.
Collapse
Affiliation(s)
- Hui Zhou
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Yuesong Wang
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Matthew Gatcombe
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Jacob Farris
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Julianne C Botelho
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Samuel P Caudill
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA
| | - Hubert W Vesper
- Centers For Disease Control and Prevention, National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Hwy NE, Atlanta, GA, 30341, USA.
| |
Collapse
|
20
|
Three Wishes for the Future of Point-of-Care Testing. POINT OF CARE 2016. [DOI: 10.1097/poc.0000000000000116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
Gallo MV, Ravenscroft J, Carpenter DO, Frye C, Akwesasne Task Force On The Environment, Cook B, Schell LM. Endocrine disrupting chemicals and ovulation: Is there a relationship? ENVIRONMENTAL RESEARCH 2016; 151:410-418. [PMID: 27543788 DOI: 10.1016/j.envres.2016.08.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 08/04/2016] [Accepted: 08/07/2016] [Indexed: 05/11/2023]
Abstract
Although the potential for endocrine disrupting chemicals (EDCs) to disrupt female fecundity is great, few studies have assessed the threat to human reproduction. This study investigates levels of organochlorines in relation to their impact on women's menstrual cycles and ovulatory status. To address concerns of the Akwesasne Mohawk community in upstate New York regarding well-established exposure to EDCs, women's fertility and reproductive health endpoints, we recruited 215 women between the ages of 21 and 38 years to measure menstrual cycle characteristics and levels of local pollutants. Of these, 155 women collected saliva over the course of their menstrual cycle allowing for analysis of estradiol and progesterone levels and the determination of ovulatory status in relationship to their serum pollutant levels. A subset of participants (15) who did not commence cycling within a month of their enrollment were not included in the analysis, hence reducing the sample size to 140 participants. Additionally, a lipid panel, estradiol and progesterone were assessed in serum on Day 3 of the menstrual cycle. Median cycle length for women in the sample was 29 days. After aligning the cycles, 110 women were considered ovulatory and 45 (29%) anovulatory. Concentrations of groups of more persistent PCBs congeners, HCB, and p,p'-DDE did not differ significantly with ovulatory status. However, a sub-group of low-chlorinated PCB congeners, considered to be estrogenic were significantly higher among anovulatory women. These findings suggest that certain EDC's, ubiquitous in our environment, may adversely affect menstrual cycles and thus have the capacity to impair reproductive function, including likelihood of conception.
Collapse
Affiliation(s)
- Mia V Gallo
- University at Albany, Department of Anthropology, A&S 237, 1400 Washington Avenue, Albany, NY, United States; Center for the Elimination of Minority Health Disparities, University at Albany-SUNY, 1400 Washington Avenue, Albany, NY, United States.
| | - Julia Ravenscroft
- University at Albany, Department of Anthropology, A&S 237, 1400 Washington Avenue, Albany, NY, United States
| | - David O Carpenter
- Center for the Elimination of Minority Health Disparities, University at Albany-SUNY, 1400 Washington Avenue, Albany, NY, United States; Institute for Health and the Environment, University at Albany, 5 University Place, Rensselaer, NY, United States
| | - Cheryl Frye
- University at Albany, Department of Psychology, 1400 Washington Avenue, Albany, NY, United States
| | | | - Beverly Cook
- St. Regis Mohawk Tribal Council, Akwesasne, NY, United States
| | - Lawrence M Schell
- University at Albany, Department of Anthropology, A&S 237, 1400 Washington Avenue, Albany, NY, United States; Center for the Elimination of Minority Health Disparities, University at Albany-SUNY, 1400 Washington Avenue, Albany, NY, United States; Institute for Health and the Environment, University at Albany, 5 University Place, Rensselaer, NY, United States; University at Albany, Department of Epidemiology and Biostatistics, School of Public Health, One University Place, Room 131, Rensselaer, NY, United States
| |
Collapse
|
22
|
Botelho JC, Ribera A, Cooper HC, Vesper HW. Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum. Anal Chem 2016; 88:11123-11129. [PMID: 27744701 DOI: 10.1021/acs.analchem.6b03220] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The inaccuracy of 17-β estradiol (E2) measurements affects its use as a biomarker in patient care and research. Clinical and research communities called for accurate and standardized E2 measurements. Reference Measurement Procedures (RMPs), part of the CDC Hormone Standardization Program (HoSt), are essential in addressing this need and ensuring that methods are accurate and comparable across testing systems, laboratories, and over time. A candidate RMP (cRMP) was developed for the measurement of total E2 in serum using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without derivatization. The cRMP meets suggested performance criteria for accuracy and precision through the use of isotope dilution, calibrator bracketing, and gravimetric measurements. The cRMP demonstrated high agreement with certified reference materials (no significant bias to BCR576, 577, and 578) and established RMPs (slope 1.00, 95% CI 1.00-1.01; intercept 0.02, 95% CI -0.01 to 0.06). The cRMP is highly precise with intra-assay, interassay, and total percent CVs of 2.7%, 1.3%, and 2.4%, respectively. A higher specificity was achieved by measuring E2 without derivatization, compared to methods using derivatization agents. The cRMP can serve as a higher-order standard for establishing measurement traceability and provides an accuracy base against which routine methods can be compared in HoSt.
Collapse
Affiliation(s)
- Julianne Cook Botelho
- Centers For Disease Control And Prevention , National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Highway NE, Atlanta, Georgia 30341, United States
| | - Ashley Ribera
- Centers For Disease Control And Prevention , National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Highway NE, Atlanta, Georgia 30341, United States
| | - Hans C Cooper
- Centers For Disease Control And Prevention , National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Highway NE, Atlanta, Georgia 30341, United States
| | - Hubert W Vesper
- Centers For Disease Control And Prevention , National Center For Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, 4770 Buford Highway NE, Atlanta, Georgia 30341, United States
| |
Collapse
|
23
|
Taylor AE, Keevil B, Huhtaniemi IT. Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow. Eur J Endocrinol 2015; 173:D1-12. [PMID: 25877990 DOI: 10.1530/eje-15-0338] [Citation(s) in RCA: 181] [Impact Index Per Article: 20.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2015] [Accepted: 04/15/2015] [Indexed: 11/08/2022]
Abstract
The recent onslaught of mass spectrometry (MS) to measurements of steroid hormones, including demands that they should be the only acceptable method, has confused clinicians and scientists who have relied for more than 40 years on a variety of immunoassay (IA) methods in steroid hormone measurements. There is little doubt that MS methods with their superior specificity will be the future method of choice in many clinical and research applications of steroid hormone measurement. However, the majority of steroid measurements are currently, and will continue to be, carried out using various types of IAs for several reasons, including their technical ease, cost and availability of commercial reagents. Speedy replacement of all IAs with MS is an unrealistic and unnecessary goal, because the availability of MS measurements is limited by cost, need of expensive equipment, technical demands and lack of commercial applications. Furthermore, IAs have multiple well-known advantages that vindicate their continuing use. The purpose of this article is to elucidate the advantages and limitations of the MS and IA techniques from two angles, i.e. promotion of MS and defence of IA. The purpose of the text is to give the reader an unbiased view about the current state and future trends of steroid analysis and to help him/her choose the correct assay method to serve his/her diagnostic and research needs.
Collapse
Affiliation(s)
- Angela E Taylor
- School of MedicineCentre for Endocrinology, Diabetes and Metabolism, University of Birmingham, Birmingham, UKDepartment of Clinical BiochemistryManchester Academic Health Science Centre, University Hospital of S Manchester, The University of Manchester, Manchester, UKDepartment of Surgery and CancerImperial College London, Institute of Reproductive and Developmental Biology, Hammersmith Campus, London W12 0NN, UKDepartment of PhysiologyInstitute of Biomedicine, University of Turku, 20520 Turku, Finland
| | - Brian Keevil
- School of MedicineCentre for Endocrinology, Diabetes and Metabolism, University of Birmingham, Birmingham, UKDepartment of Clinical BiochemistryManchester Academic Health Science Centre, University Hospital of S Manchester, The University of Manchester, Manchester, UKDepartment of Surgery and CancerImperial College London, Institute of Reproductive and Developmental Biology, Hammersmith Campus, London W12 0NN, UKDepartment of PhysiologyInstitute of Biomedicine, University of Turku, 20520 Turku, Finland
| | - Ilpo T Huhtaniemi
- School of MedicineCentre for Endocrinology, Diabetes and Metabolism, University of Birmingham, Birmingham, UKDepartment of Clinical BiochemistryManchester Academic Health Science Centre, University Hospital of S Manchester, The University of Manchester, Manchester, UKDepartment of Surgery and CancerImperial College London, Institute of Reproductive and Developmental Biology, Hammersmith Campus, London W12 0NN, UKDepartment of PhysiologyInstitute of Biomedicine, University of Turku, 20520 Turku, Finland School of MedicineCentre for Endocrinology, Diabetes and Metabolism, University of Birmingham, Birmingham, UKDepartment of Clinical BiochemistryManchester Academic Health Science Centre, University Hospital of S Manchester, The University of Manchester, Manchester, UKDepartment of Surgery and CancerImperial College London, Institute of Reproductive and Developmental Biology, Hammersmith Campus, London W12 0NN, UKDepartment of PhysiologyInstitute of Biomedicine, University of Turku, 20520 Turku, Finland
| |
Collapse
|
24
|
Ziegler RG, Fuhrman BJ, Moore SC, Matthews CE. Epidemiologic studies of estrogen metabolism and breast cancer. Steroids 2015; 99:67-75. [PMID: 25725255 PMCID: PMC5722219 DOI: 10.1016/j.steroids.2015.02.015] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Accepted: 12/29/2014] [Indexed: 12/21/2022]
Abstract
Early epidemiologic studies of estrogen metabolism measured only 2-hydroxyestrone and 16α-hydroxyestrone and relied on direct enzyme immunoassays without purification steps. Eight breast cancer studies have used these assays with prospectively collected blood or urine samples. Results were inconsistent, and generally not statistically significant; but the assays had limited specificity, especially at the low concentrations characteristic of postmenopausal women. To facilitate continued testing in population-based studies of the multiple laboratory-based hypotheses about the roles of estrogen metabolites, a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed to measure concurrently all 15 estrogens and estrogen metabolites in human serum and urine, as unconjugated and total (glucuronidated+sulfated+unconjugated) concentrations. The assay has high sensitivity (lower limit of quantitation ∼1-2 pmol/L), reproducibility (coefficients of variation generally ⩽5%), and accuracy. Three prospective studies utilizing this comprehensive assay have demonstrated that enhanced 2-hydroxylation of parent estrogens (estrone+estradiol) is associated with reduced risk of postmenopausal breast cancer. In the Prostate, Lung, Colorectal, and Ovarian Cancer Screening Trial (PLCO) cohort, the serum ratio of 2-hydroxylation pathway metabolites to parent estrogens was associated with a 28% reduction in breast cancer risk across extreme deciles (p-trend=.05), after adjusting for unconjugated estradiol and breast cancer risk factors. Incorporating this ratio into a risk prediction model already including unconjugated estradiol improved absolute risk estimates substantially (by ⩾14%) in 36% of the women, an encouraging result that needs replication. Additional epidemiologic studies of the role of estrogen metabolism in the etiology of hormone-related diseases and continued improvement of estrogen metabolism assays are justified.
Collapse
Affiliation(s)
- Regina G Ziegler
- Epidemiology and Biostatistics Program, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD 20892-9773, USA.
| | - Barbara J Fuhrman
- Epidemiology and Biostatistics Program, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD 20892-9773, USA
| | - Steven C Moore
- Epidemiology and Biostatistics Program, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD 20892-9773, USA
| | - Charles E Matthews
- Epidemiology and Biostatistics Program, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD 20892-9773, USA
| |
Collapse
|
25
|
Abstract
Estradiol quantitation is useful in the clinical assessment of diseases like hypogonadism, hirsutism, polycystic ovary syndrome (PCOS), amenorrhea, ovarian tumors and for monitoring response in women receiving aromatase inhibitor therapy. Physiologically relevant serum estradiol concentration in women can span across four orders of magnitude. For example, in women undergoing ovulation induction serum estradiol concentration can range between 250-2000 pg/mL whereas aromatase inhibitor therapy can decrease serum estradiol concentration to <5 pg/mL. While high-through-put automated un-extracted (direct) immunoassays accommodate the growing clinical need for estradiol quantitation, are amenable to implementation by most hospital clinical laboratories, they display a significant loss of specificity and accuracy at low concentrations. Most clinical scenarios (example: estradiol monitoring in fertility treatments) place a modest demand on accuracy and precision of the assay in use but accurate quantitation of estradiol in certain clinical scenarios (pediatric and male patients and for monitoring aromatase inhibitor therapy) can be challenging using currently available immunoassays since the direct immunoassays are prone to issues with sub-optimal accuracy and specificity due to cross reactivity with estradiol conjugates and metabolites. In this review we discuss the bases for the evolution of estradiol assays from extracted (indirect) radio-immunoassays to direct immunoassays to liquid-chromatography tandem mass spectrometry (LC-MS/MS) based assays, discuss technical factors relevant for development and optimization of a LC-MS/MS assay for estradiol and present the details and performance characteristics of an ultra-sensitive LC-MS/MS estradiol assay with a limit of quantitation of 0.2 pg/mL.
Collapse
Affiliation(s)
- Hemamalini Ketha
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, United States
| | - Adam Girtman
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, United States
| | - Ravinder J Singh
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, United States.
| |
Collapse
|
26
|
Wang Q, Rangiah K, Mesaros C, Snyder NW, Vachani A, Song H, Blair IA. Ultrasensitive quantification of serum estrogens in postmenopausal women and older men by liquid chromatography-tandem mass spectrometry. Steroids 2015; 96:140-52. [PMID: 25637677 PMCID: PMC4369926 DOI: 10.1016/j.steroids.2015.01.014] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2014] [Revised: 01/07/2015] [Accepted: 01/13/2015] [Indexed: 12/21/2022]
Abstract
An ultrasensitive stable isotope dilution liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for multiplexed quantitative analysis of six unconjugated and conjugated estrogens in human serum. The quantification utilized a new derivatization procedure, which formed analytes as pre-ionized N-methyl pyridinium-3-sulfonyl (NMPS) derivatives. This method required only 0.1mL of human serum, yet was capable of simultaneously quantifying six estrogens within 20min. The lower limit of quantitation (LLOQ) for estradiol (E2), 16α-hydroxy (OH)-E2, 4-methoxy (MeO)-E2 and 2-MeO-E2 was 1fg on column, and was 10fg on column for 4-OH-E2 and 2-OH-E2. All analytes demonstrated a linear response from 0.5 to 200pg/mL (5-2000pg/mL for 4-OH-E2 and 2-OH-E2). Using this validated method, the estrogen levels in human serum samples from 20 female patients and 20 male patients were analyzed and compared. The levels found for unconjugated serum E2 from postmenopausal women (mean 2.7pg/mL) were very similar to those obtained by highly sensitive gas chromatography-mass spectrometry (GC-MS) methodology. However, the level obtained in serum from older men (mean 9.5pg/mL) was lower than has been reported previously by both GC-MS and LC-MS procedures. The total (unconjugated+conjugated) 4-MeO-E2 levels were significantly higher in female samples compared with males (p<0.05). The enhanced sensitivity offered by the present method will allow for a more specific analysis of estrogens and their metabolites. Our observations might suggest that the level of total 4-MeO-E2 could be a potential biomarker for breast cancer cases.
Collapse
Affiliation(s)
- Qingqing Wang
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Systems Pharmacology and Translational Therapeutics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Pharmacology and Toxicology, Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Kannan Rangiah
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Systems Pharmacology and Translational Therapeutics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; NCBS, Center for Cellular and Molecular Platforms, Bangalore, India
| | - Clementina Mesaros
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Systems Pharmacology and Translational Therapeutics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Nathaniel W Snyder
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Systems Pharmacology and Translational Therapeutics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States
| | - Anil Vachani
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Division of Pulmonary, Allergy and Critical Care, University of Pennsylvania School of Medicine, Philadelphia, PA 19104, United States
| | - Haifeng Song
- Department of Pharmacology and Toxicology, Beijing Institute of Radiation Medicine, Beijing 100850, China
| | - Ian A Blair
- Center of Excellence in Environmental Toxicology and Penn SRP Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States; Department of Systems Pharmacology and Translational Therapeutics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, United States.
| |
Collapse
|
27
|
Pennell KD, Woodin MA, Pennell PB. Quantification of neurosteroids during pregnancy using selective ion monitoring mass spectrometry. Steroids 2015; 95:24-31. [PMID: 25541057 PMCID: PMC4323841 DOI: 10.1016/j.steroids.2014.12.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2014] [Revised: 10/30/2014] [Accepted: 12/12/2014] [Indexed: 10/24/2022]
Abstract
Analytical techniques used to quantify neurosteroids in biological samples are often compromised by non-specificity and limited dynamic range which can result in erroneous results. A relatively rapid and inexpensive gas chromatography-mass spectrometry (GC-MS) was developed to simultaneously measure nine neurosteroids, including allopregnanolone, estradiol, and progesterone, as well as 25-hydroxy-vitamin D3 in plasma samples collected from adult women subjects during and after pregnancy. Sample preparation involved solid-phase extraction and derivatization, followed by automated injection on a GC equipped with a mass selective detector (MSD) operated in single ion monitoring (SIM) mode to yield a run time of less than 11min. Method detection limits for all neurosteroids ranged from 30 to 200pg/mL (parts per trillion), with coefficients of variation that ranged from 3% to 5% based on intra-assay comparisons run in triplicate. Although concentrations of estradiol measured by chemiluminescent immunoassay (CIA) were consistent with values determined by GC-MS values, CIA yielded considerable higher values of progesterone, suggesting antibody cross reactions resulting from low specificity. Mean neurosteroid levels and representative time-course data demonstrate the ability of the method to quantify changes in multiple neurosteroids during pregnancy, including rapid declines in neurosteroid levels associated with delivery. This simplified GC-MS method holds particular promise for research and clinical laboratories that require simultaneous quantification of multiple neurosteroids, but lack the resources and expertise to support advanced liquid chromatography-tandem mass spectrometry facilities.
Collapse
Affiliation(s)
- Kurt D Pennell
- Department of Civil and Environmental Engineering, School of Engineering, Tufts University, 200 College Avenue, Medford, MA 02155, United States.
| | - Mark A Woodin
- Department of Civil and Environmental Engineering, School of Engineering, Tufts University, 200 College Avenue, Medford, MA 02155, United States; Department of Public Health and Community Medicine, School of Medicine, Tufts University, 136 Harrison Avenue, Boston, MA 02111, United States
| | - Page B Pennell
- Division of Epilepsy, Department of Neurology, Division of Women's Health, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, United States
| |
Collapse
|