1
|
Sundström M, Kriikku P, Ojanperä I, Baessmann C, Pelander A. UHPLC-QTOFMS Urine Drug Screening With Dilute-and-Shoot Sample Preparation and Vacuum-Insulated Probe-Heated Electrospray Ionization. Drug Test Anal 2024. [PMID: 39532671 DOI: 10.1002/dta.3830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 10/29/2024] [Accepted: 10/31/2024] [Indexed: 11/16/2024]
Abstract
We developed a method for comprehensive urine drug screening by applying dilute-and-shoot extraction and vacuum-insulated probe-heated electrospray ionization with ultra-high performance liquid chromatography high-resolution quadrupole time-of-flight mass spectrometry (DS-UHPLC-VIP-HESI-QTOFMS). The method involved five-fold post-hydrolysis dilution of urine samples and chromatography on a C18 UHPLC column prior to QTOFMS analysis. The recently introduced VIP-HESI ion source was chosen due to its enhanced ionization efficiency and compatibility with UHPLC-QTOFMS. Extensive data was acquired in positive ion mode with a low collision energy (7 eV) and an elevated collision energy (30 eV), using the broadband collision-induced dissociation data acquisition scan mode that continuously generated high-resolution and accurate mass for parent and fragment qualifier ions, and parent ion isotopic patterns. Compound identification was performed against an in-house database with 1263 compound entries, using an automated post-run reverse target database search with preset identification criteria. Method validation with 56 different drugs showed acceptable results for the limit of identification (median 5 ng/mL), matrix effects (70-130%), repeatability of retention times (< 1%), mass accuracy (< 1 mDa), as well as for specificity and stability. As compared with an established UHPLC-QTOFMS method relying on solid-phase extraction and conventional electrospray ionization, DS-UHPLC-VIP-HESI-QTOFMS produced comparable results from authentic clinical urine samples for most drugs, but showed clearly improved detectability for pregabalin, gabapentin, and ritalinic acid. We anticipate that the new method will be a step forward for laboratories performing routine urine drug screening due to its fast turnaround time, reduced manual workload, cost efficiency, and broad substance coverage.
Collapse
Affiliation(s)
- Mira Sundström
- Forensic Chemistry Unit, Finnish Institute for Health and Welfare (THL), Helsinki, Finland
| | - Pirkko Kriikku
- Forensic Chemistry Unit, Finnish Institute for Health and Welfare (THL), Helsinki, Finland
- Department of Forensic Medicine, University of Helsinki, Helsinki, Finland
| | - Ilkka Ojanperä
- Forensic Chemistry Unit, Finnish Institute for Health and Welfare (THL), Helsinki, Finland
- Department of Forensic Medicine, University of Helsinki, Helsinki, Finland
| | | | - Anna Pelander
- Forensic Chemistry Unit, Finnish Institute for Health and Welfare (THL), Helsinki, Finland
| |
Collapse
|
2
|
Lai Y, Koelmel JP, Walker DI, Price EJ, Papazian S, Manz KE, Castilla-Fernández D, Bowden JA, Nikiforov V, David A, Bessonneau V, Amer B, Seethapathy S, Hu X, Lin EZ, Jbebli A, McNeil BR, Barupal D, Cerasa M, Xie H, Kalia V, Nandakumar R, Singh R, Tian Z, Gao P, Zhao Y, Froment J, Rostkowski P, Dubey S, Coufalíková K, Seličová H, Hecht H, Liu S, Udhani HH, Restituito S, Tchou-Wong KM, Lu K, Martin JW, Warth B, Godri Pollitt KJ, Klánová J, Fiehn O, Metz TO, Pennell KD, Jones DP, Miller GW. High-Resolution Mass Spectrometry for Human Exposomics: Expanding Chemical Space Coverage. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:12784-12822. [PMID: 38984754 PMCID: PMC11271014 DOI: 10.1021/acs.est.4c01156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 06/11/2024] [Accepted: 06/12/2024] [Indexed: 07/11/2024]
Abstract
In the modern "omics" era, measurement of the human exposome is a critical missing link between genetic drivers and disease outcomes. High-resolution mass spectrometry (HRMS), routinely used in proteomics and metabolomics, has emerged as a leading technology to broadly profile chemical exposure agents and related biomolecules for accurate mass measurement, high sensitivity, rapid data acquisition, and increased resolution of chemical space. Non-targeted approaches are increasingly accessible, supporting a shift from conventional hypothesis-driven, quantitation-centric targeted analyses toward data-driven, hypothesis-generating chemical exposome-wide profiling. However, HRMS-based exposomics encounters unique challenges. New analytical and computational infrastructures are needed to expand the analysis coverage through streamlined, scalable, and harmonized workflows and data pipelines that permit longitudinal chemical exposome tracking, retrospective validation, and multi-omics integration for meaningful health-oriented inferences. In this article, we survey the literature on state-of-the-art HRMS-based technologies, review current analytical workflows and informatic pipelines, and provide an up-to-date reference on exposomic approaches for chemists, toxicologists, epidemiologists, care providers, and stakeholders in health sciences and medicine. We propose efforts to benchmark fit-for-purpose platforms for expanding coverage of chemical space, including gas/liquid chromatography-HRMS (GC-HRMS and LC-HRMS), and discuss opportunities, challenges, and strategies to advance the burgeoning field of the exposome.
Collapse
Affiliation(s)
- Yunjia Lai
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Jeremy P. Koelmel
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Douglas I. Walker
- Gangarosa
Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia 30322, United States
| | - Elliott J. Price
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Stefano Papazian
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
- National
Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Katherine E. Manz
- Department
of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Delia Castilla-Fernández
- Department
of Food Chemistry and Toxicology, Faculty of Chemistry, University of Vienna, 1010 Vienna, Austria
| | - John A. Bowden
- Center for
Environmental and Human Toxicology, Department of Physiological Sciences,
College of Veterinary Medicine, University
of Florida, Gainesville, Florida 32611, United States
| | | | - Arthur David
- Univ Rennes,
Inserm, EHESP, Irset (Institut de recherche en santé, environnement
et travail) − UMR_S, 1085 Rennes, France
| | - Vincent Bessonneau
- Univ Rennes,
Inserm, EHESP, Irset (Institut de recherche en santé, environnement
et travail) − UMR_S, 1085 Rennes, France
| | - Bashar Amer
- Thermo
Fisher Scientific, San Jose, California 95134, United States
| | | | - Xin Hu
- Gangarosa
Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, Georgia 30322, United States
| | - Elizabeth Z. Lin
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Akrem Jbebli
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Brooklynn R. McNeil
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Dinesh Barupal
- Department
of Environmental Medicine and Public Health, Icahn School of Medicine at Mount Sinai, New York, New York 10029, United States
| | - Marina Cerasa
- Institute
of Atmospheric Pollution Research, Italian National Research Council, 00015 Monterotondo, Rome, Italy
| | - Hongyu Xie
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
| | - Vrinda Kalia
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Renu Nandakumar
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Randolph Singh
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Zhenyu Tian
- Department
of Chemistry and Chemical Biology, Northeastern
University, Boston, Massachusetts 02115, United States
| | - Peng Gao
- Department
of Environmental and Occupational Health, and Department of Civil
and Environmental Engineering, University
of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- UPMC Hillman
Cancer Center, Pittsburgh, Pennsylvania 15232, United States
| | - Yujia Zhao
- Institute
for Risk Assessment Sciences, Utrecht University, Utrecht 3584CM, The Netherlands
| | | | | | - Saurabh Dubey
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Kateřina Coufalíková
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Hana Seličová
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Helge Hecht
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Sheng Liu
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Hanisha H. Udhani
- Biomarkers
Core Laboratory, Irving Institute for Clinical and Translational Research, Columbia University Irving Medical Center, New York, New York 10032, United States
| | - Sophie Restituito
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Kam-Meng Tchou-Wong
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| | - Kun Lu
- Department
of Environmental Sciences and Engineering, Gillings School of Global
Public Health, The University of North Carolina
at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Jonathan W. Martin
- Department
of Environmental Science, Science for Life Laboratory, Stockholm University, SE-106 91 Stockholm, Sweden
- National
Facility for Exposomics, Metabolomics Platform, Science for Life Laboratory, Stockholm University, Solna 171 65, Sweden
| | - Benedikt Warth
- Department
of Food Chemistry and Toxicology, Faculty of Chemistry, University of Vienna, 1010 Vienna, Austria
| | - Krystal J. Godri Pollitt
- Department
of Environmental Health Sciences, Yale School
of Public Health, New Haven, Connecticut 06520, United States
| | - Jana Klánová
- RECETOX,
Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic
| | - Oliver Fiehn
- West Coast
Metabolomics Center, University of California−Davis, Davis, California 95616, United States
| | - Thomas O. Metz
- Biological
Sciences Division, Pacific Northwest National
Laboratory, Richland, Washington 99354, United States
| | - Kurt D. Pennell
- School
of Engineering, Brown University, Providence, Rhode Island 02912, United States
| | - Dean P. Jones
- Department
of Medicine, School of Medicine, Emory University, Atlanta, Georgia 30322, United States
| | - Gary W. Miller
- Department
of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York 10032, United States
| |
Collapse
|
3
|
Tamama K. Dilute and shoot approach for toxicology testing. Front Chem 2023; 11:1278313. [PMID: 38146427 PMCID: PMC10749341 DOI: 10.3389/fchem.2023.1278313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 11/27/2023] [Indexed: 12/27/2023] Open
Abstract
Toxicology testing is performed in clinical settings, forensic settings, and for controlling doping. Drug screening is a toxicology test to determine if drugs are present in biological samples. The most common specimen type for drug testing is urine, as drugs and/or their metabolites are often more concentrated in the urine, extending the detection window of drugs. The dilute-and-shoot method is a simple procedure used in toxicology testing, where a sample is diluted before being directly injected into the liquid chromatography-mass spectrometry (LC-MS) system. This method is easy, quick, and cost-saving, and can be used for protein-poor liquid specimens such as urine. Thus, it is reasonable and attractive for busy toxicology laboratories to combine the dilute-and-shoot method with high-resolution hyphenated-MS for urine drug screening. This method has several disadvantages, including a suboptimal detection capability for certain analytes, as well as interference from co-eluting matrix components called matrix effects, in which co-eluting matrix molecules alter the ionization efficiency of the analyte molecules at the ionization source in LC-MS, altering (mostly reducing) the analyte detection capability. The matrix effect testing is essential for the validation of LC-MS-based assays. A reasonable approach to addressing these undesirable effects would be to minimize these components. The most straightforward approach is to reduce the amounts of matrix components by using a higher dilution of the specimen and a lower volume for specimen injection. Optimization of the chromatographic separation is another reasonable approach for reducing co-eluting matrix components with the analyte.
Collapse
Affiliation(s)
- Kenichi Tamama
- Clinical Laboratories, University of Pittsburgh Medical Center, Pittsburgh, PA, United States
- Department of Pathology, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
4
|
González-Rubio S, Caballero-Casero N, Ballesteros-Gómez A, Cuervo D, Muñoz G, Rubio S. Supramolecular solvents for making comprehensive liquid-liquid microextraction in multiclass screening methods for drugs of abuse in urine based on liquid chromatography-high resolution mass spectrometry. J Chromatogr A 2023; 1701:464061. [PMID: 37187096 DOI: 10.1016/j.chroma.2023.464061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/05/2023] [Accepted: 05/08/2023] [Indexed: 05/17/2023]
Abstract
Multiclass screening methods involving hundreds of structurally unrelated compounds are becoming essential in many control labs and research areas. Accurate mass screening of a theoretically unlimited number of chemicals can be undertaken using liquid chromatography coupled to high resolution mass spectrometry (LCHRMS), but the lack of comprehensive sample treatments hinders this unlimited potential. In this research, the capability of supramolecular solvents (SUPRAS) for making comprehensive liquid-liquid microextraction (LLME) in multiclass screening methods based on LCHRMS was firstly explored. For this purpose, a SUPRAS made up of 1,2-hexanediol, sodium sulphate and water was synthesized directly in the urine and applied to compound extraction and interference removal in the screening of eighty prohibited substances in sports by LC-electrospray ionization-time of flight mass spectrometry. Selected substances included a wide range of polarities (log P from -2.4 to 9.2) and functionalities (e.g. alcohol, amine, amide, carboxyl, ether, ester, ketone, sulfonyl, etc.). No interfering peaks were observed for any of the 80 substances investigated. Around 84-93% of drugs were efficiently extracted (recoveries 70-120%) and 83-94% of the analytes did not show matrix effects (±20%) in the ten tested urines. Method detection limits for the drugs were in the interval 0.002-12.9 ng mL-1, which are in accordance with the Minimum Required Performance Levels values established by the World Anti-Doping Agency. The applicability of the method was evaluated by the screening of thirty-six blinded and anonymized urine samples, previously analyzed by gas or liquid chromatography-triple quadrupole. Seven of the samples lead to an adverse analytical finding in line with the results obtained by the conventional methods. This research proves that LLME based on SUPRAS constitutes an efficient, economic, and simple sample treatment in multiclass screening methods, an application that is unaffordable for conventional organic solvents.
Collapse
Affiliation(s)
- Soledad González-Rubio
- Department of Analytical Chemistry, Instituto Químico para la Energía y el Medioambiente, Marie Curie Building (Annex), Campus of Rabanales, Universidad de Córdoba, Córdoba 14071, Spain
| | - Noelia Caballero-Casero
- Department of Analytical Chemistry, Instituto Químico para la Energía y el Medioambiente, Marie Curie Building (Annex), Campus of Rabanales, Universidad de Córdoba, Córdoba 14071, Spain.
| | - Ana Ballesteros-Gómez
- Department of Analytical Chemistry, Instituto Químico para la Energía y el Medioambiente, Marie Curie Building (Annex), Campus of Rabanales, Universidad de Córdoba, Córdoba 14071, Spain
| | - Darío Cuervo
- Doping Control Laboratory. Institute of Health Carlos III, C/ Pintor el Greco S/N, Madrid 28040, Spain
| | - Gloria Muñoz
- Doping Control Laboratory. Institute of Health Carlos III, C/ Pintor el Greco S/N, Madrid 28040, Spain
| | - Soledad Rubio
- Department of Analytical Chemistry, Instituto Químico para la Energía y el Medioambiente, Marie Curie Building (Annex), Campus of Rabanales, Universidad de Córdoba, Córdoba 14071, Spain
| |
Collapse
|
5
|
Chen HW, Liu HT, Kuo YN, Yang DP, Ting TT, Chen JH, Chiu JY, Jair YC, Li HC, Chiang PJ, Chen WR, Lin MC, Hsu YH, Chen PS. Rapid and sensitive dilute-and-shoot analysis using LC-MS-MS for identification of multi-class psychoactive substances in human urine. J Pharm Biomed Anal 2023; 233:115443. [PMID: 37210892 DOI: 10.1016/j.jpba.2023.115443] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/22/2023] [Accepted: 05/03/2023] [Indexed: 05/23/2023]
Abstract
The emergence of new psychoactive substances currently exceeding a thousand is rapidly changing substance prevalence patterns and straining the methods used for detection, most of which are suitable only for a single class of substances. This study presents a rapid and facile dilute-and-shoot system operated in conjunction with an optimized liquid chromatographic separation system for the high-sensitivity detection of substances across a range of substance classes with 3 isotopes used only. The proposed method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) is able to identify 68 substance and their metabolites in urine samples as small as 50 μL. Optimal chromatographic conditions including 95% water/methanol ratio with 0.1% added formic acid and a prolonged LC gradient run-time (15 min) improved the peak shape of polar compounds and enhanced signal strength by 5%. Under 4-fold dilution, all analytes were within 80-120% of tolerance response levels, indicating that the matrix effect was insignificant. In experiments, the limit of detection (LOD) ranged from 0.05 to 0.5 ng mL-1, while the coefficient of determination (R2) was > 0.9950. The retention time shift of each peak remained at < 2% with an inter-day relative standard deviation (RSD) of 0.9-14.9% and intra-day RSD of 1.1%- 13.8%. The rapid dilute-and-shoot presents a high-sensitivity, significant stability, robustness and reproducibility without serious interference. To demonstrate the effectiveness of the system, 532 urine samples were collected from suspected drug abusers, and the proposed method was used for rapid analysis. Of these samples, 79.5% contained between one and twelve analytes, and 12.4% tested positive for new psychoactive substances, mostly derivatives of amphetamine and synthetic cathinones. The study presents a high-sensitivity analytic system that is capable of detecting substances from multiple classes and can be used for effective monitoring of substance prevalence in urine.
Collapse
Affiliation(s)
- Huei-Wen Chen
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Hsin-Tung Liu
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Yun-Ning Kuo
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Da-Peng Yang
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Te-Tien Ting
- School of Big Data Management, Soochow University, Taipei, Taiwan, ROC
| | - Jung-Hsuan Chen
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Jui-Yi Chiu
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Yung-Cheng Jair
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Hsu-Cheng Li
- Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan, ROC
| | - Pin-Ju Chiang
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Wei-Ru Chen
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC
| | - Mei-Chih Lin
- Taiwan Food and Drug Administration, Taipei, Taiwan, ROC
| | - Ya-Hui Hsu
- Taiwan Food and Drug Administration, Taipei, Taiwan, ROC
| | - Pai-Shan Chen
- Graduate Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC.
| |
Collapse
|
6
|
Scanferla DTP, Sano Lini R, Marchioni C, Mossini SAG. Drugs of abuse: A narrative review of recent trends in biological sample preparation and chromatographic techniques. Forensic Chem 2022. [DOI: 10.1016/j.forc.2022.100442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
7
|
Lim GM, Kim BG, Jeong HJ. Trap column-based intact mass spectrometry for rapid and accurate evaluation of protein molecular weight. RSC Adv 2022; 12:15643-15651. [PMID: 35685704 PMCID: PMC9126647 DOI: 10.1039/d2ra00429a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 03/24/2022] [Indexed: 11/21/2022] Open
Abstract
The determination of the molecular weight (MW) of a protein using high-resolution mass spectrometry (MS) is a crucial tool used to confirm whether the protein was correctly expressed and adequately purified. However, a non-volatile buffer is normally used for protein purification and storage. Therefore, a pre-treatment step using ultrafiltration (UF) is required to exchange the buffer with a volatile buffer prior to the introduction of the protein sample into the MS equipment. This pre-treatment step is time-consuming. In this study, a trap column-based pre-treatment method applied in a nano-LC system was developed for rapid and convenient analysis of the MW of proteins. First, the trap column system was compared with the conventional UF treatment system and non-treatment system using bovine serum albumin. Subsequently, the trap column system was applied to analyze the MW of commercially available and lab-synthesized recombinant proteins. The intensity of the base peak and signal-to-noise ratio of the trap column-based pre-treated protein were higher than those of the UF-treated protein. Moreover, the entire automated procedure of the trap column-based system was conducted within 20 min, which confirms its use in versatile and accurate protein identification.
Collapse
Affiliation(s)
- Gyu-Min Lim
- Interdisciplinary Program for Biochemical Engineering and Biotechnology, Seoul National University Seoul 08826 South Korea
| | - Byung-Gee Kim
- Interdisciplinary Program for Biochemical Engineering and Biotechnology, Seoul National University Seoul 08826 South Korea
- Bio-MAX/N-Bio, Seoul National University Seoul 08826 South Korea
| | - Hee-Jin Jeong
- Department of Biological and Chemical Engineering, Hongik University Sejong 30016 South Korea
| |
Collapse
|
8
|
Delcourt V, Garcia P, Pottier I, Mansoibou N, Bache N, Glavieux Y, Chabot B, Perot I, André F, Loup B, Barnabé A, Popot MA, Bailly-Chouriberry L. Development of a Standardized Microflow LC Gradient to Enable Sensitive and Long-Term Detection of Synthetic Anabolic-Androgenic Steroids for High-Throughput Doping Controls. Anal Chem 2021; 93:15590-15596. [PMID: 34791882 DOI: 10.1021/acs.analchem.1c03392] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Synthetic androgenic anabolic steroids (AAS) are banned compounds and considered as major threats by both racing and sports international authorities. Hence, doping control laboratories are continually looking into analytical improvements to increase their detection capabilities, notably by means of emerging technologies. To enhance analytical performances for the detection of synthetic AAS such as stanozolol, specific chromatographic procedures have been developed using recent quaternary liquid chromatography technology originally designed for high-throughput standardized proteomics connected to mass spectrometry. Applying the newly designed elution procedures described in this paper to the analyses of stanozolol and its metabolites in complex matrixes revealed improved sensitivity compared to previously described high-throughput methods. Indeed, we report the consistent and reliable detection of 16β-hydroxy-stanozolol down to 10 pg/mL in equine urine and being detectable up-to 3 months after a microdosing administration. Furthermore, a five months long elimination of stanozolol and its metabolites could be monitored on horse mane sections after a single dose administration. Our work highlights novel solutions to detect AAS with improved sensitivity. The application of such developments constitutes new landmarks for doping control laboratories and could be extended to other targeted compounds in residue analysis, toxicology, and metabolomics. Based on this work, the developed chromatographic method is now freely available within the Evosep Plus program.
Collapse
Affiliation(s)
- Vivian Delcourt
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Patrice Garcia
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Isabelle Pottier
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Nasrine Mansoibou
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Nicolai Bache
- Evosep Biosystems, Buchwaldsgade 35, Third Floor, DK-5000 Odense C, Denmark
| | - Yohan Glavieux
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Benjamin Chabot
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Isabelle Perot
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - François André
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Benoit Loup
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Agnès Barnabé
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | - Marie-Agnès Popot
- GIE-LCH, Laboratoire des Courses Hippiques, 15 Rue de Paradis, 91370 Verrières-le-Buisson, France
| | | |
Collapse
|
9
|
|
10
|
Redefining dilute and shoot: The evolution of the technique and its application in the analysis of foods and biological matrices by liquid chromatography mass spectrometry. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116284] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
11
|
Coppieters G, Deventer K, Van Eenoo P, Judák P. Combining direct urinary injection with automated filtration and nanoflow LC-MS for the confirmatory analysis of doping-relevant small peptide hormones. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122842. [PMID: 34216910 DOI: 10.1016/j.jchromb.2021.122842] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/16/2021] [Accepted: 06/18/2021] [Indexed: 01/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) has proven itself as a powerful tool and its scope entails various applications in (bio)analytical fields. Operation at low (nL/min) flow rates in combination with reduced inner dimensions (ID < 100 µm), leads to significantly enhanced sensitivity when coupled with electrospray ionization-mass spectrometry (ESI-MS). Challenges that remain for the routine implementation of such miniaturized setups are related to clogging of the system and robustness in general, and thus the application of tedious sample preparation steps. To improve ruggedness, a filter placed upstream in the LC prevents particles from entering and clogging the system. This so-called online automatic filtration and filter back-flush (AFFL) system was combined with nanoLC and the direct injection principle for the sensitive confirmatory analysis of fifty different doping-relevant peptides in urine. The presented assay was fully validated for routine purposes according to selectivity and matrix interference, limit of identification (LOI), carryover, matrix effect, sample extract stability, analysis of educational external quality assessment (EQAS) samples, robustness of the online AFFL-setup and retention time stability. It was also fully compliant with the most recent minimum required performance levels (MRPL) and chromatographic/mass spectrometric identification criteria (IDCR), as imposed by the World Anti-Doping Agency (WADA). In the absence of labor-intensive sample preparation, the application of AFFL allowed for the injection of diluted urine samples without any noticeable pressure buildup in the nanoLC system. Contrary to earlier observations by our group and others, the addition of dimethylsulfoxide (DMSO) to the mobile phase did not enhance sensitivity in the presented nanoflow setup, yet was beneficial to reduce carry over. Although the robustness of the presented setup was evaluated only for the analysis of diluted urine samples, it is entirely conceivable that routine applications employing other matrices and currently running on analytical scale LC instruments could be transferred to micro/nanoLC scale systems to reach lower detection limits.
Collapse
Affiliation(s)
- Gilles Coppieters
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium.
| | - Koen Deventer
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| | - Peter Van Eenoo
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| | - Péter Judák
- Doping Control Laboratory (DoCoLab), Ghent University, Department Diagnostic Sciences, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
| |
Collapse
|
12
|
Mainero Rocca L, L’Episcopo N, Gordiani A, Vitali M, Staderini A. A 'Dilute and Shoot' Liquid Chromatography-Mass Spectrometry Method for Multiclass Drug Analysis in Pre-Cut Dried Blood Spots. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:3068. [PMID: 33809736 PMCID: PMC8002310 DOI: 10.3390/ijerph18063068] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/12/2021] [Accepted: 03/13/2021] [Indexed: 01/26/2023]
Abstract
Drugs able to affect the auditory and nervous systems and consumed by workers to treatdifferent pathologies can represent a possible source of risk in the work environment. All the target compounds involved in the presented project show ototoxic and/or narcoleptic side effects and, for these reasons, occupational safety organizations have recognized them as potential causes of work injuries. A multiclass method for the analysis of 15 drugs among the most widespread worldwide (belonging to nine different classes including antihistamines, beta-blockers, antidepressants, Z-drugs and opioids), was developed and validated. This study describes a rapid, sensitive and effective method to analyse these substances in whole blood using tailored pre-cut dried blood spots. Detection was achieved with a triple quadrupole mass spectrometer after an easy and simple 'dilute and shoot' solubilisation followed by an UPLC separation. All the issues linked to the use of the dried blood spots and whole blood, such as haematocrit variability, volumetric evaluation and sample carrier choice were carefully studied and managed during method development. From the validation study results it emerged that this approach can be deemed successful thanks to its few pg µL-1 LOQs, good linear intervals, absolute recoveries of no less than 75%, an almost negligible matrix effect and accuracy and precision in line with the European and American guidelines for validation. All the obtained goals have been specifically pursued in order to encourage method diffusion as a primary prevention intervention, even in small private workplaces.
Collapse
Affiliation(s)
- Lucia Mainero Rocca
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers’ Compensation Authority (INAIL)—, Via Fontana Candida 1, Monte Porzio Catone, 00078 Rome, Italy; (N.L.); (A.G.); (A.S.)
| | - Nunziata L’Episcopo
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers’ Compensation Authority (INAIL)—, Via Fontana Candida 1, Monte Porzio Catone, 00078 Rome, Italy; (N.L.); (A.G.); (A.S.)
| | - Andrea Gordiani
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers’ Compensation Authority (INAIL)—, Via Fontana Candida 1, Monte Porzio Catone, 00078 Rome, Italy; (N.L.); (A.G.); (A.S.)
| | - Matteo Vitali
- Department of Public Health and Infectious Diseases, University of Rome La Sapienza, P.le Aldo Moro, 5, 00185 Rome, Italy;
| | - Alessandro Staderini
- Chemical Agents Laboratory, Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers’ Compensation Authority (INAIL)—, Via Fontana Candida 1, Monte Porzio Catone, 00078 Rome, Italy; (N.L.); (A.G.); (A.S.)
| |
Collapse
|
13
|
Maurer HH. Hyphenated high-resolution mass spectrometry-the "all-in-one" device in analytical toxicology? Anal Bioanal Chem 2020; 413:2303-2309. [PMID: 33247339 PMCID: PMC7987635 DOI: 10.1007/s00216-020-03064-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 10/29/2020] [Accepted: 11/11/2020] [Indexed: 12/24/2022]
Abstract
This trend article reviews papers with hyphenated high-resolution mass spectrometry (HRMS) approaches applied in analytical toxicology, particularly in clinical and forensic toxicology published since 2016 and referenced in PubMed. The article focuses on the question of whether HRMS has or will become the all-in-one device in these fields as supposed by the increasing number of HRMS presentations at scientific meetings, corresponding original papers, and review articles. Typical examples for the different application fields are discussed such as targeted or untargeted drug screening, quantification, drug metabolism studies, and metabolomics approaches. Considering the reviewed papers, HRMS is currently the only technique that fulfills the criteria of an all-in-one device for the various applications needed in analytical toxicology. Graphical abstract![]()
Collapse
Affiliation(s)
- Hans H Maurer
- Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, 66421, Homburg (Saar), Germany.
| |
Collapse
|
14
|
Borden SA, Palaty J, Termopoli V, Famiglini G, Cappiello A, Gill CG, Palma P. MASS SPECTROMETRY ANALYSIS OF DRUGS OF ABUSE: CHALLENGES AND EMERGING STRATEGIES. MASS SPECTROMETRY REVIEWS 2020; 39:703-744. [PMID: 32048319 DOI: 10.1002/mas.21624] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Mass spectrometry has been the "gold standard" for drugs of abuse (DoA) analysis for many decades because of the selectivity and sensitivity it affords. Recent progress in all aspects of mass spectrometry has seen significant developments in the field of DoA analysis. Mass spectrometry is particularly well suited to address the rapidly proliferating number of very high potency, novel psychoactive substances that are causing an alarming number of fatalities worldwide. This review surveys advancements in the areas of sample preparation, gas and liquid chromatography-mass spectrometry, as well as the rapidly emerging field of ambient ionization mass spectrometry. We have predominantly targeted literature progress over the past ten years and present our outlook for the future. © 2020 Periodicals, Inc. Mass Spec Rev.
Collapse
Affiliation(s)
- Scott A Borden
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
| | - Jan Palaty
- LifeLabs Medical Laboratories, Burnaby, BC, V3W 1H8, Canada
| | - Veronica Termopoli
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Giorgio Famiglini
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Achille Cappiello
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, 98195
| | - Pierangela Palma
- Applied Environmental Research Laboratories (AERL), Department of Chemistry, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada
- LC-MS Laboratory, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, 61029, Urbino, Italy
| |
Collapse
|
15
|
Brown HM, McDaniel TJ, Fedick PW, Mulligan CC. The current role of mass spectrometry in forensics and future prospects. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3974-3997. [PMID: 32720670 DOI: 10.1039/d0ay01113d] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Mass spectrometry (MS) techniques are highly prevalent in crime laboratories, particularly those coupled to chromatographic separations like gas chromatography (GC) and liquid chromatography (LC). These methods are considered "gold standard" analytical techniques for forensic analysis and have been extensively validated for producing prosecutorial evidentiary data. However, factors such as growing evidence backlogs and problematic evidence types (e.g., novel psychoactive substance (NPS) classes) have exposed limitations of these stalwart techniques. This critical review serves to delineate the current role of MS methods across the broad sub-disciplines of forensic science, providing insight on how governmental steering committees guide their implementation. Novel, developing techniques that seek to broaden applicability and enhance performance will also be highlighted, from unique modifications to traditional hyphenated MS methods to the newer "ambient" MS techniques that show promise for forensic analysis, but need further validation before incorporation into routine forensic workflows. This review also expounds on how recent improvements to MS instrumental design, scan modes, and data processing could cause a paradigm shift in how the future forensic practitioner collects and processes target evidence.
Collapse
Affiliation(s)
- Hilary M Brown
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, USA.
| | | | | | | |
Collapse
|
16
|
Jia W, Shi L, Zhang F, Chang J, Chu X. High-throughput mass spectrometry scheme for screening and quantification of flavonoids in antioxidant nutraceuticals. J Chromatogr A 2019; 1608:460408. [PMID: 31378531 DOI: 10.1016/j.chroma.2019.460408] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 07/12/2019] [Accepted: 07/26/2019] [Indexed: 01/03/2023]
Abstract
Antioxidant nutraceuticals functional characteristic science is a challenging field for combining sensitivity and comprehensiveness. A untargeted screening and quantification method based on ultra-high performance liquid chromatography coupled to Quadrupole-Orbitrap high resolution mass spectrometry has been developed for determination of multiple classes of flavonoids in eight-three nutraceuticals samples. The data acquisition is based on a non-target approach of sequential full scan and variable data independent acquisition of twenty consecutive fragmentation events. The flavonoids include flavanols, flavones, flavanones, anthocyanidins, flavonols and isoflavones. A processing strategy is introduced to implementing filtering methods based on data feature extraction, common ion selection, shoulder peak removal, response threshold adjustment, mass shift and characteristic structural fragments evaluation. Confirmation is based on both accurate mass and isotopic assignment of standards, and further quantification is achieved by fragmentation. This scheme allows in depth characterization of flavonoids with the entire fragments.
Collapse
Affiliation(s)
- Wei Jia
- School of Food and Biological Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China; Chinese Academy of Inspection and Quarantine, Beijing, 100123, China.
| | - Lin Shi
- School of Food and Biological Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China.
| | - Feng Zhang
- Chinese Academy of Inspection and Quarantine, Beijing, 100123, China.
| | - James Chang
- Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA, United States.
| | - Xiaogang Chu
- School of Food and Biological Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China; Chinese Academy of Inspection and Quarantine, Beijing, 100123, China.
| |
Collapse
|
17
|
Thevis M, Kuuranne T, Geyer H. Annual banned-substance review: Analytical approaches in human sports drug testing. Drug Test Anal 2019; 11:8-26. [DOI: 10.1002/dta.2549] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Accepted: 11/18/2018] [Indexed: 12/12/2022]
Affiliation(s)
- Mario Thevis
- Center for Preventive Doping Research - Institute of Biochemistry; German Sport University Cologne; Cologne Germany
- European Monitoring Center for Emerging Doping Agents; Cologne Germany
| | - Tiia Kuuranne
- Swiss Laboratory for Doping Analyses; University Center of Legal Medicine, Genève and Lausanne, Centre Hospitalier Universitaire Vaudois and University of Lausanne; Epalinges Switzerland
| | - Hans Geyer
- Center for Preventive Doping Research - Institute of Biochemistry; German Sport University Cologne; Cologne Germany
- European Monitoring Center for Emerging Doping Agents; Cologne Germany
| |
Collapse
|
18
|
Abstract
Nano liquid chromatography (nanoLC), with columns having an inner diameter (ID) of ≤100 μm, can provide enhanced sensitivity and enable analysis of limited samples.
Collapse
Affiliation(s)
- Steven Ray Wilson
- Department of Chemistry
- University of Oslo
- Oslo
- Norway
- Hybrid Technology Hub-Centre of Excellence
| | | | | |
Collapse
|