1
|
Sakai Y, Yamada S, Inoue M, Shiga T, Konagayoshi K, Kasai K, Kimura A, Murakami K. Efficacy of a DNA vaccine encoding the E2 glycoprotein of bovine viral diarrhea virus 1 fused to mouse lysosome-associated membrane protein 1. Vet Microbiol 2024; 298:110283. [PMID: 39488135 DOI: 10.1016/j.vetmic.2024.110283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 10/17/2024] [Accepted: 10/20/2024] [Indexed: 11/04/2024]
Abstract
The E2 protein of bovine viral diarrhea virus (BVDV) is a known protective antigen and a major target for DNA vaccines. DNA vaccines have various advantages; however, their immunogenicity needs to be enhanced by using adjuvants or drug delivery systems. In this study, we used mouse lysosome-associated membrane protein 1 (mLAMP1) as a molecular adjuvant and developed a DNA vaccine encoding an mLAMP1-BVDV E2 chimeric protein (pVax-mLAMP1-E2). We constructed DNA plasmids in which the E2 gene was inserted within the hinge region (H) or membrane proximal domain (D) of the mLAMP1 gene. Transfection of these plasmids into cultured cells led to high expression of E2 antigen from pVax-mLAMP1-E2 (H). Intradermal immunization of mice with pVax-mLAMP1-E2 (H) induced sufficient neutralizing antibodies and splenocytes with E2 antigen-specific IFN-γ production compared with pVax-mLAMP1-E2 (D). However, the immunogenicity of pVax mLAMP1-E2 (H) in mice did not differ from that of a control plasmid without the LAMP1 molecule (pVax-E2). In cattle, geometric mean serum neutralizing antibody titers after intradermal or intramuscular injection tended to be higher with pVax-mLAMP1-E2 (H) than with pVax that expressed E2 without mLAMP1. In addition, E2 antigen-specific IFN-γ production in peripheral blood mononuclear cells from cattle immunized intradermally with pVax-mLAMP1-E2 (H) was not significantly different from that of pVax-E2. These results suggest that mLAMP1 fusion antigens effectively induce humoral and cellular immunity in mice and cattle, especially when the antigen is inserted in the hinge region of mLAMP1. The LAMP1-E2 fusion antigen may be a useful candidate for a BVDV DNA vaccine in cattle.
Collapse
Affiliation(s)
- Yusuke Sakai
- Graduate School of Veterinary Sciences, Iwate University, Morioka, Iwate 020-8550, Japan; Nippon Zenyaku Kogyo Co., Ltd., Koriyama, Fukushima 963-0196, Japan
| | - Shinji Yamada
- Graduate School of Veterinary Sciences, Iwate University, Morioka, Iwate 020-8550, Japan; Cooperative Department of Veterinary Medicine, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan; Farm Animal Clinic and Disease Control Center, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan
| | - Maho Inoue
- Cooperative Department of Veterinary Medicine, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan
| | - Toshinori Shiga
- Nippon Zenyaku Kogyo Co., Ltd., Koriyama, Fukushima 963-0196, Japan
| | | | - Kei Kasai
- Nippon Zenyaku Kogyo Co., Ltd., Koriyama, Fukushima 963-0196, Japan
| | - Atsushi Kimura
- Graduate School of Veterinary Sciences, Iwate University, Morioka, Iwate 020-8550, Japan; Farm Animal Clinic and Disease Control Center, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan
| | - Kenji Murakami
- Graduate School of Veterinary Sciences, Iwate University, Morioka, Iwate 020-8550, Japan; Cooperative Department of Veterinary Medicine, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan; Farm Animal Clinic and Disease Control Center, Faculty of Agriculture, Iwate University, Morioka, Iwate 020-8550, Japan.
| |
Collapse
|
2
|
Zheng Y, Li Z, Li S, Zhao P, Wang X, Lu S, Shi Y, Chang H. Separable nanocomposite hydrogel microneedles for intradermal and sustained delivery of antigens to enhance adaptive immune responses. Acta Biomater 2024; 185:203-214. [PMID: 39053817 DOI: 10.1016/j.actbio.2024.07.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 07/03/2024] [Accepted: 07/18/2024] [Indexed: 07/27/2024]
Abstract
Vaccines play a critical role in combating infectious diseases and cancers, yet improving their efficacy remains challenging. Here, we introduce a separable nanocomposite hydrogel microneedle (NHMN) patch designed for intradermal and sustained delivery of ovalbumin (OVA), a model antigen, to enhance adaptive immune responses. The NHMN patch consists of an array of OVA-loaded microneedles made from photo-cross-linked methacrylated hyaluronic acid and laponite (LAP), supported by a hyaluronic acid backing. The incorporation of LAP not only enhances the mechanical strength of the pure hydrogel microneedles but also significantly prolongs OVA release. Furthermore, in vitro cell experiments demonstrate that NHMNs effectively activate dendritic cells without compromising cell viability. Upon skin penetration, NHMNs detach from the backing as the hyaluronic acid rapidly dissolves upon contact with the skin interstitial fluid, thereby acting as antigen reservoirs to release antigens to abundant skin dendritic cells. NHMNs containing 0.5% w/v LAP achieved a 15-day OVA release in vivo. Immunization studies demonstrate that the intradermal and sustained release of OVA via NHMNs elicited stronger and longer-lasting adaptive immune responses compared to conventional bolus injection. Given its easy to use, painless and minimally invasive features, the NHMN patch shows promise in improving vaccination accessibility and efficacy against a range of diseases. STATEMENT OF SIGNIFICANCE: The study introduces a separable nanocomposite hydrogel microneedle (NHMN) patch. This patch consists of an array of ovalbumin (OVA, a model antigen)-loaded microneedles made from photo-cross-linked methacrylated hyaluronic acid and laponite, with a hyaluronic acid backing, designed for intradermal and sustained delivery of antigens. This patch addresses several key challenges in traditional vaccination methods, including poor antigen uptake and presentation, and rapid systematic clearance. The incorporation of laponite enhances mechanical strength of microneedles, promotes dendritic cell activation, and significantly slows down antigen release. NHMN-based vaccination elicits stronger and longer-lasting adaptive immune responses compared to conventional bolus injection. This NHMN patch holds great potential for improving the efficacy, accessibility, and patient comfort of vaccinations against a range of diseases.
Collapse
Affiliation(s)
- Yanting Zheng
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, Zhejiang, China
| | - Zhiming Li
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China
| | - Shaohua Li
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, Zhejiang, China
| | - Puxuan Zhao
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, Zhejiang, 310014, China
| | - Xin Wang
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, Zhejiang, 310014, China
| | - Shaojie Lu
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; College of Materials Science and Engineering, Zhejiang University of Technology, Hangzhou, Zhejiang, 310014, China
| | - Yanan Shi
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China; Medical School, Faculty of Medicine, Tianjin University, Tianjin 300072, China
| | - Hao Chang
- Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou 310018, Zhejiang, China.
| |
Collapse
|
3
|
Raj S, Vishwakarma P, Saxena S, Kumar V, Khatri R, Kumar A, Singh M, Mishra S, Asthana S, Ahmed S, Samal S. Intradermal Immunization of Soluble Influenza HA Derived from a Lethal Virus Induces High Magnitude and Breadth of Antibody Responses and Provides Complete Protection In Vivo. Vaccines (Basel) 2023; 11:780. [PMID: 37112692 PMCID: PMC10141624 DOI: 10.3390/vaccines11040780] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 03/05/2023] [Accepted: 03/07/2023] [Indexed: 04/05/2023] Open
Abstract
Immunogens mimicking the native-like structure of surface-exposed viral antigens are considered promising vaccine candidates. Influenza viruses are important zoonotic respiratory viruses with high pandemic potential. Recombinant soluble hemagglutinin (HA) glycoprotein-based protein subunit vaccines against Influenza have been shown to induce protective efficacy when administered intramuscularly. Here, we have expressed a recombinant soluble trimeric HA protein in Expi 293F cells and purified the protein derived from the Inf A/Guangdong-Maonan/ SWL1536/2019 virus which was found to be highly virulent in the mouse. The trimeric HA protein was found to be in the oligomeric state, highly stable, and the efficacy study in the BALB/c mouse challenge model through intradermal immunization with the prime-boost regimen conferred complete protection against a high lethal dose of homologous and mouse-adapted InfA/PR8 virus challenge. Furthermore, the immunogen induced high hemagglutinin inhibition (HI) titers and showed cross-protection against other Inf A and Inf B subtypes. The results are promising and warrant trimeric HA as a suitable vaccine candidate.
Collapse
Affiliation(s)
- Sneha Raj
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Preeti Vishwakarma
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Shikha Saxena
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Varun Kumar
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Ritika Khatri
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Amit Kumar
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Mrityunjay Singh
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Surbhi Mishra
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Shailendra Asthana
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| | - Shubbir Ahmed
- Centralized Core Research Facility (CCRF), All India Institute of Medical Sciences, New Delhi 110029, India
| | - Sweety Samal
- Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad 121001, India
| |
Collapse
|
4
|
Beaujean M, Uijen RF, Langereis JD, Boccara D, Dam D, Soria A, Veldhuis G, Adam L, Bonduelle O, van der Wel NN, Luirink J, Pedruzzi E, Wissink J, de Jonge MI, Combadière B. The immunological effects of intradermal particle-based vaccine delivery using a novel microinjection needle studied in a human skin explant model. Vaccine 2023; 41:2270-2279. [PMID: 36870875 DOI: 10.1016/j.vaccine.2023.02.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 01/27/2023] [Accepted: 02/13/2023] [Indexed: 03/06/2023]
Abstract
For intradermal (ID) immunisation, novel needle-based delivery systems have been proposed as a better alternative to the Mantoux method. However, the penetration depth of needles in the human skin and its effect on immune cells residing in the different layers of the skin has not been analyzed. A novel and user-friendly silicon microinjection needle (Bella-muTM) has been developed, which allows for a perpendicular injection due to its short needle length (1.4-1.8 mm) and ultrashort bevel. We aimed to characterize the performance of this microinjection needle in the context of the delivery of a particle-based outer membrane vesicle (OMV) vaccine using an ex vivo human skin explant model. We compared the needles of 1.4 and 1.8 mm with the conventional Mantoux method to investigate the depth of vaccine injection and the capacity of the skin antigen-presenting cell (APC) to phagocytose the OMVs. The 1.4 mm needle deposited the antigen closer to the epidermis than the 1.8 mm needle or the Mantoux method. Consequently, activation of epidermal Langerhans cells was significantly higher as determined by dendrite shortening. We found that five different subsets of dermal APCs are able to phagocytose the OMV vaccine, irrespective of the device or injection method. ID delivery using the 1.4 mm needle of a OMV-based vaccine allowed epidermal and dermal APC targeting, with superior activation of Langerhans cells. This study indicates that the use of a microinjection needle improves the delivery of vaccines in the human skin.
Collapse
Affiliation(s)
- Manon Beaujean
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France
| | - Rienke F Uijen
- Laboratory of Medical Immunology, Radboud Center for Infectious Diseases, Radboud Institute for Molecular Sciences, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Jeroen D Langereis
- Laboratory of Medical Immunology, Radboud Center for Infectious Diseases, Radboud Institute for Molecular Sciences, Radboud University Medical Center, Nijmegen, the Netherlands
| | - David Boccara
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France; Hôpital Saint Louis, Reconstructive and Cosmetic and Burn, Paris, France
| | - Denise Dam
- U-Needle B.V., Enschede, the Netherlands
| | - Angèle Soria
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France; Service de Dermatologie et d'Allergologie, Hôpital Tenon, Paris HUEP, APHP, Paris, France
| | | | - Lucille Adam
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France
| | - Olivia Bonduelle
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France
| | - Nicole N van der Wel
- Department of Medical Biology, Electron Microscopy Center Amsterdam, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
| | - Joen Luirink
- Department of Molecular Microbiology, Amsterdam Institute of Molecular and Life Sciences (AIMMS), Vrije Universiteit, De Boelelaan, 1085, 1081 HV Amsterdam, the Netherlands
| | - Eric Pedruzzi
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France
| | | | - Marien I de Jonge
- Laboratory of Medical Immunology, Radboud Center for Infectious Diseases, Radboud Institute for Molecular Sciences, Radboud University Medical Center, Nijmegen, the Netherlands.
| | - Behazine Combadière
- Sorbonne Université, Inserm U1135, Centre d'Immunologie et des Maladies Infectieuses (Cimi), Paris, France
| |
Collapse
|
5
|
Wang J, Lu Z, Cai R, Zheng H, Yu J, Zhang Y, Gu Z. Microneedle-based transdermal detection and sensing devices. LAB ON A CHIP 2023; 23:869-887. [PMID: 36629050 DOI: 10.1039/d2lc00790h] [Citation(s) in RCA: 28] [Impact Index Per Article: 28.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Microneedles have been expected for the construction of next-generation biosensors towards personalization, digitization, and intellectualization due to their metrics of minimal invasiveness, high integration, and favorable biocompatibility. Herein, an overview of state-of-the-art microneedle-based detection and sensing systems is presented. First, the designs of microneedle devices based on extraction mechanisms are concluded, corresponding to different geometries and materials of microneedles. Second, the targets of equipment-assisted microneedle detections are summarized, as well as the objective significance, revealing the current performance and potential scenarios of these microneedles. Third, the trend towards highly integrated sensors is elaborated by emphasizing the sensing principles (colorimetric, fluorometric and electronic manner). Finally, the key challenges to be tackled and the perspectives on future development are discussed.
Collapse
Affiliation(s)
- Junxia Wang
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
| | - Ziyi Lu
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
| | - Ruisi Cai
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
| | - Hanqi Zheng
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
| | - Jicheng Yu
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
- Jinhua Institute of Zhejiang University, Jinhua, 321299, China
- Liangzhu Laboratory, Zhejiang University Medical Center, Hangzhou, 311121, China
| | - Yuqi Zhang
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
- Department of Burns and Wound Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, China
| | - Zhen Gu
- Zhejiang Provincial Key Laboratory for Advanced Drug Delivery Systems, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, 310058, China.
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, 310016, China
- Jinhua Institute of Zhejiang University, Jinhua, 321299, China
- Liangzhu Laboratory, Zhejiang University Medical Center, Hangzhou, 311121, China
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, 310027, China
| |
Collapse
|
6
|
Choo JJY, McMillan CLD, Young PR, Muller DA. Microarray patches: scratching the surface of vaccine delivery. Expert Rev Vaccines 2023; 22:937-955. [PMID: 37846657 DOI: 10.1080/14760584.2023.2270598] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 10/10/2023] [Indexed: 10/18/2023]
Abstract
INTRODUCTION Microneedles are emerging as a promising technology for vaccine delivery, with numerous advantages over traditional needle and syringe methods. Preclinical studies have demonstrated the effectiveness of MAPs in inducing robust immune responses over traditional needle and syringe methods, with extensive studies using vaccines targeted against different pathogens in various animal models. Critically, the clinical trials have demonstrated safety, immunogenicity, and patient acceptance for MAP-based vaccines against influenza, measles, rubella, and SARS-CoV-2. AREAS COVERED This review provides a comprehensive overview of the different types of microarray patches (MAPs) and analyses of their applications in preclinical and clinical vaccine delivery settings. This review also covers additional considerations for microneedle-based vaccination, including adjuvants that are compatible with MAPs, patient safety and factors for global vaccination campaigns. EXPERT OPINION MAP vaccine delivery can potentially be a game-changer for vaccine distribution and coverage in both high-income and low- and middle-income countries. For MAPs to reach this full potential, many critical hurdles must be overcome, such as large-scale production, regulatory compliance, and adoption by global health authorities. However, given the considerable strides made in recent years by MAP developers, it may be possible to see the first MAP-based vaccines in use within the next 5 years.
Collapse
Affiliation(s)
- Jovin J Y Choo
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
| | - Christopher L D McMillan
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
- Australian Infectious Diseases Research Centre, School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
| | - Paul R Young
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
- Australian Infectious Diseases Research Centre, School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
| | - David A Muller
- School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
- Australian Infectious Diseases Research Centre, School of Chemistry and Molecular Biosciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
7
|
Milián-Suazo F, González-Ruiz S, Contreras-Magallanes YG, Sosa-Gallegos SL, Bárcenas-Reyes I, Cantó-Alarcón GJ, Rodríguez-Hernández E. Vaccination Strategies in a Potential Use of the Vaccine against Bovine Tuberculosis in Infected Herds. Animals (Basel) 2022; 12:ani12233377. [PMID: 36496897 PMCID: PMC9735741 DOI: 10.3390/ani12233377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 11/11/2022] [Accepted: 11/29/2022] [Indexed: 12/04/2022] Open
Abstract
Bovine tuberculosis (bTB) is a disease of cattle that represents a risk to public health and causes severe economic losses to the livestock industry. Recently, one of the strategies recommended for reducing the prevalence of the disease in animals is the use of the BCG vaccine, alone or in combination with proteins. It has been shown that the vaccine elicits a strong immune response, downsizes the number of animals with visible lesions, and reduces the rate of infection as well as the bacillary count. This paper, based on scientific evidence, makes suggestions about some practical vaccination alternatives that can be used in infected herds to reduce bTB prevalence, considering BCG strains, vaccine doses, routes of application, and age of the animals. Our conclusion is that vaccination is a promising alternative to be included in current control programs in underdeveloped countries to reduce the disease burden.
Collapse
Affiliation(s)
- Feliciano Milián-Suazo
- Facultad de Ciencias Naturales, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | - Sara González-Ruiz
- Facultad de Ciencias Naturales, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
- Correspondence:
| | | | | | - Isabel Bárcenas-Reyes
- Facultad de Ciencias Naturales, Universidad Autónoma de Querétaro, Santiago de Querétaro 76010, Mexico
| | | | - Elba Rodríguez-Hernández
- Centro Nacional de Investigación Disciplinaria en Fisiología y Mejoramiento Animal, Instituto Nacional de Investigaciones Forestales, Agrícolas y Pecuarias, Ajuchitlán 76280, Mexico
| |
Collapse
|
8
|
Malek-Khatabi A, Tabandeh Z, Nouri A, Mozayan E, Sartorius R, Rahimi S, Jamaledin R. Long-Term Vaccine Delivery and Immunological Responses Using Biodegradable Polymer-Based Carriers. ACS APPLIED BIO MATERIALS 2022; 5:5015-5040. [PMID: 36214209 DOI: 10.1021/acsabm.2c00638] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Biodegradable polymers are largely employed in the biomedical field, ranging from tissue regeneration to drug/vaccine delivery. The biodegradable polymers are highly biocompatible and possess negligible toxicity. In addition, biomaterial-based vaccines possess adjuvant properties, thereby enhancing immune responses. This Review introduces the use of different biodegradable polymers and their degradation mechanism. Different kinds of vaccines, as well as the interaction between the carriers with the immune system, then are highlighted. Natural and synthetic biodegradable micro-/nanoplatforms, hydrogels, and scaffolds for local or targeted and controlled vaccine release are subsequently discussed.
Collapse
Affiliation(s)
- Atefeh Malek-Khatabi
- Department of Pharmaceutical Biomaterials, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 1417614411, Iran
| | - Zahra Tabandeh
- Department of Physical Chemistry, Faculty of Chemistry, University of Kashan, Kashan 8731753153, Iran
| | - Akram Nouri
- School of Chemistry, College of Science, University of Tehran, Tehran 141556455, Iran
| | - Elaheh Mozayan
- Department of Cell and Molecular Biology, University of Kashan, Kashan 8731753153, Iran
| | | | - Shahnaz Rahimi
- School of Chemistry, College of Science, University of Tehran, Tehran 141556455, Iran
| | - Rezvan Jamaledin
- Department of Chemical, Materials & Industrial Production Engineering, University of Naples Federico II, Naples 80125, Italy
| |
Collapse
|
9
|
Terui H, Kimura N, Segawa R, Kusama S, Abe H, Terutsuki D, Yamasaki K, Nishizawa M. Intradermal vaccination via electroosmotic injection from a porous microneedle patch. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2022.103711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
10
|
Cao X, Chen G. Advances in microneedles for non-transdermal applications. Expert Opin Drug Deliv 2022; 19:1081-1097. [DOI: 10.1080/17425247.2022.2118711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Xiaona Cao
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada
- Rosalind & Morris Goodman Cancer Institute, McGill University, Montreal, Quebec, Canada
- School of Nursing, Tianjin Medical University, Tianjin, China
| | - Guojun Chen
- Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada
- Rosalind & Morris Goodman Cancer Institute, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
11
|
Li XJ, Li Y, Meng Y, Pu XQ, Qin JW, Xie R, Wang W, Liu Z, Jiang L, Ju XJ, Chu LY. Composite dissolvable microneedle patch for therapy of oral mucosal diseases. BIOMATERIALS ADVANCES 2022; 139:213001. [PMID: 35882148 DOI: 10.1016/j.bioadv.2022.213001] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 06/15/2023]
Abstract
A composite microneedle patch (MN patch) is developed for oral transmucosal administration. To improve the oral transmucosal drug delivery efficiency, the composite MN patch is designed to consist of an array of 100 dissolvable microneedles (MNs) with drug-loaded tips and a backing layer. The MNs are composed of two parts, the hyaluronic acid (HA) tip part and the polyvinylpyrrolidone (PVP) base part. Due to the small size and sufficient mechanical strength, the HA-PVP MNs can painlessly penetrate the oral mucosa barrier and deliver drugs directly to the basal layer or submucosa. Betamethasone sodium phosphate (BSP), as the model drug, is concentrated in the HA tip parts to avoid the drug waste caused by mucosa elasticity. Considering the special moist environment and saliva flow in the mouth, a double-layer backing layer composed of a poly(vinyl alcohol) (PVA) adhesive layer and an ethyl cellulose (EC) waterproof layer is designed and constructed, which could reduce the saliva flow effects. The in vitro and in vivo results demonstrate that the MN patch could achieve rapid and efficient BSP release in oral mucosa due to the rapid dissolution of HA. The proposed MN patch provides a novel strategy for the therapy of oral mucosal diseases.
Collapse
Affiliation(s)
- Xin-Jiao Li
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Yao Li
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Yang Meng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Xing-Qun Pu
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Jia-Wang Qin
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Rui Xie
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Wei Wang
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Zhuang Liu
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| | - Lu Jiang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China.
| | - Xiao-Jie Ju
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China.
| | - Liang-Yin Chu
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, Sichuan 610065, PR China
| |
Collapse
|
12
|
Sartawi Z, Blackshields C, Faisal W. Dissolving microneedles: Applications and growing therapeutic potential. J Control Release 2022; 348:186-205. [PMID: 35662577 DOI: 10.1016/j.jconrel.2022.05.045] [Citation(s) in RCA: 119] [Impact Index Per Article: 59.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/20/2022] [Accepted: 05/26/2022] [Indexed: 12/15/2022]
Abstract
Microneedles are a rapidly developing method for the transdermal delivery of therapeutic compounds. All types of microneedles, whether solid, hollow, coated, or dissolving function by penetrating the stratum corneum layer of the skin producing a microchannel through which therapeutic agents may be delivered. To date, coated and hollow microneedles have been the most successful, despite suffering from issues such as poor drug loading capabilities and blocked pores. Dissolving microneedles, on the other hand, have superior drug loading as well as other positive attributes that make it an ideal delivery system, including simple methods of fabrication and disposal, and abundantly available materials. Indeed, dissolvable microneedles can even be fabricated entirely from the therapeutic agent itself thus eliminating the requirement for additional excipients. This focused review presents the recent developments and trends of dissolving microneedles as well as potential future directions. The advantages, and disadvantages of dissolving microneedles as well as fabrication materials and methods are discussed. The potential applications of dissolving microneedles as a drug delivery system in different therapeutic areas in both research literature and clinical trials is highlighted. Applications including the delivery of cosmetics, vaccine delivery, diagnosis and monitoring, cancer, pain and inflammation, diabetes, hair and scalp disorders and inflammatory skin diseases are presented. The current trends observed in the microneedle landscape with particular emphasis on contemporary clinical trials and commercial successes as well as barriers impeding microneedle development and commercialisation are also discussed.
Collapse
Affiliation(s)
- Ziad Sartawi
- School of Pharmacy, University College Cork, Cork, Ireland
| | | | - Waleed Faisal
- School of Pharmacy, University College Cork, Cork, Ireland.
| |
Collapse
|
13
|
Relative Effectiveness of Cell-Cultured versus Egg-Based Seasonal Influenza Vaccines in Preventing Influenza-Related Outcomes in Subjects 18 Years Old or Older: A Systematic Review and Meta-Analysis. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19020818. [PMID: 35055642 PMCID: PMC8775496 DOI: 10.3390/ijerph19020818] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 11/23/2021] [Accepted: 11/27/2021] [Indexed: 02/06/2023]
Abstract
Avian mutations in vaccine strains obtained from embryonated eggs could impair vaccine effectiveness. We performed a systematic review and meta-analysis of the adjusted relative vaccine effectiveness (arVE) of seed cell-cultured influenza vaccines (ccIV) compared to egg-based influenza vaccines (eIV) in preventing laboratory-confirmed influenza related outcomes (IRO) or IRO by clinical codes, in subjects 18 and over. We completed the literature search in January 2021; applied exclusion criteria, evaluated risk of bias of the evidence, and performed heterogeneity, publication bias, qualitative, quantitative and sensitivity analyses. All estimates were computed using a random approach. International Prospective Register of Systematic Reviews, CRD42021228290. We identified 12 publications that reported 26 adjusted arVE results. Five publications reported 13 laboratory confirmed arVE and seven reported 13 code-ascertained arVE. Nine publications with 22 results were at low risk of bias. Heterogeneity was explained by season. We found a significant 11% (8 to 14%) adjusted arVE favoring ccIV in preventing any IRO in the 2017–2018 influenza season. The arVE was 3% (−2% to 7%) in the 2018–2019 influenza season. We found moderate evidence of a significant advantage of the ccIV in preventing IRO, compared to eIV, in a well-matched A(H3N2) predominant season.
Collapse
|
14
|
Performance and usability evaluation of novel intradermal injection device Immucise™ and reanalysis of intradermal administration trials of influenza vaccine for the elderly. Vaccine 2022; 40:873-879. [PMID: 35031147 DOI: 10.1016/j.vaccine.2021.12.061] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 12/21/2021] [Accepted: 12/25/2021] [Indexed: 11/24/2022]
Abstract
Under the pandemic situation, there is an urgent need to produce and acquire sufficient quantities of prophylactic vaccines. It becomes important to devise a way to achieve reliable immunity with lower doses to distribute limited supplies of vaccines to maximum number of people very quickly. Intradermal (ID) vaccination is one such method to increase the effectiveness of vaccines. However, this method has not been widely used in general clinical practice because it is technically difficult to inject vaccines precisely into the ID tissue. Therefore, new ID delivery systems that allow reliable ID administration are under development. In this paper, we summarize its design and present the results of performance and usability testing for the Immucise™ Intradermal Injection System (Immucise™). This study showed that Immucise™ can reduce dead volume and inject drugs precisely into the ID tissues of subjects from infants to the elderly and can be used correctly and safely by healthcare professionals. This randomized controlled trial compared ID administration with Immucise™ and standard subcutaneous (SC) administration of seasonal influenza vaccine by analyzing the efficacy of the vaccine in the elderly group at 90 days and 180 days after administration. It was found that the vaccine for the ID group was as effective or more effective than that for the SC group up to 180 days later. It was also found that the geometric mean titer values, especially for B strains, were higher in the two-dose ID group than in the two-dose SC group. These findings suggest that Immucise™ is one of the best devices to distribute a small amount of vaccine quickly and widely to a larger number of people with little loss of vaccine during a pandemic.
Collapse
|
15
|
Yang L, Yang Y, Chen H, Mei L, Zeng X. Polymeric microneedle-mediated sustained release systems: Design strategies and promising applications for drug delivery. Asian J Pharm Sci 2022; 17:70-86. [PMID: 35261645 PMCID: PMC8888142 DOI: 10.1016/j.ajps.2021.07.002] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 04/24/2021] [Accepted: 07/03/2021] [Indexed: 12/24/2022] Open
Abstract
Parenteral sustained release drug formulations, acting as preferable platforms for long-term exposure therapy, have been wildly used in clinical practice. However, most of these delivery systems must be given by hypodermic injection. Therefore, issues including needle-phobic, needle-stick injuries and inappropriate reuse of needles would hamper the further applications of these delivery platforms. Microneedles (MNs) as a potential alternative system for hypodermic needles can benefit from minimally invasive and self-administration. Recently, polymeric microneedle-mediated sustained release systems (MN@SRS) have opened up a new way for treatment of many diseases. Here, we reviewed the recent researches in MN@SRS for transdermal delivery, and summed up its typical design strategies and applications in various diseases therapy, particularly focusing on the applications in contraception, infection, cancer, diabetes, and subcutaneous disease. An overview of the present clinical translation difficulties and future outlook of MN@SRS was also provided.
Collapse
Affiliation(s)
- Li Yang
- Institute of Pharmaceutics, School of Pharmaceutical Sciences (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
| | - Yao Yang
- Institute of Pharmaceutics, School of Pharmaceutical Sciences (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
| | - Hongzhong Chen
- Institute of Pharmaceutics, School of Pharmaceutical Sciences (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
| | - Lin Mei
- Institute of Pharmaceutics, School of Pharmaceutical Sciences (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
- Tianjin Key Laboratory of Biomedical Materials, Key Laboratory of Biomaterials and Nanotechnology for Cancer Immunotherapy, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin 300192, China
| | - Xiaowei Zeng
- Institute of Pharmaceutics, School of Pharmaceutical Sciences (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
| |
Collapse
|
16
|
Microneedle-Mediated Vaccination: Innovation and Translation. Adv Drug Deliv Rev 2021; 179:113919. [PMID: 34375682 DOI: 10.1016/j.addr.2021.113919] [Citation(s) in RCA: 66] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 08/03/2021] [Accepted: 08/05/2021] [Indexed: 12/14/2022]
Abstract
Vaccine administration by subcutaneous or intramuscular injection is the most commonly prescribed route for inoculation, however, it is often associated with some deficiencies such as low compliance, high professionalism, and risk of infection. Therefore, the application of microneedles for vaccine delivery has gained widespread interests in the past few years due to its high compliance, minimal invasiveness, and convenience. This review focuses on recent advances in the development and application of microneedles for vaccination based on different delivery strategies, and introduces the current status of microneedle-mediated vaccination in clinical translation. The prospects for its application including opportunities and challenges are further discussed.
Collapse
|
17
|
Developing a Stabilizing Formulation of a Live Chimeric Dengue Virus Vaccine Dry Coated on a High-Density Microarray Patch. Vaccines (Basel) 2021; 9:vaccines9111301. [PMID: 34835234 PMCID: PMC8625757 DOI: 10.3390/vaccines9111301] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 11/02/2021] [Accepted: 11/05/2021] [Indexed: 11/17/2022] Open
Abstract
Alternative delivery systems such as the high-density microarray patch (HD-MAP) are being widely explored due to the variety of benefits they offer over traditional vaccine delivery methods. As vaccines are dry coated onto the HD-MAP, there is a need to ensure the stability of the vaccine in a solid state upon dry down. Other challenges faced are the structural stability during storage as a dried vaccine and during reconstitution upon application into the skin. Using a novel live chimeric virus vaccine candidate, BinJ/DENV2-prME, we explored a panel of pharmaceutical excipients to mitigate vaccine loss during the drying and storage process. This screening identified human serum albumin (HSA) as the lead stabilizing excipient. When bDENV2-coated HD-MAPs were stored at 4 °C for a month, we found complete retention of vaccine potency as assessed by the generation of potent virus-neutralizing antibody responses in mice. We also demonstrated that HD-MAP wear time did not influence vaccine deposition into the skin or the corresponding immunological outcomes. The final candidate formulation with HSA maintained ~100% percentage recovery after 6 months of storage at 4 °C.
Collapse
|
18
|
Transdermal vaccination via 3D-printed microneedles induces potent humoral and cellular immunity. Proc Natl Acad Sci U S A 2021; 118:2102595118. [PMID: 34551974 PMCID: PMC8488660 DOI: 10.1073/pnas.2102595118] [Citation(s) in RCA: 80] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/17/2021] [Indexed: 01/08/2023] Open
Abstract
Vaccination is an essential public health measure for infectious disease prevention. The exposure of the immune system to vaccine formulations with the appropriate kinetics is critical for inducing protective immunity. In this work, faceted microneedle arrays were designed and fabricated utilizing a three-dimensional (3D)-printing technique called continuous liquid interface production (CLIP). The faceted microneedle design resulted in increased surface area as compared with the smooth square pyramidal design, ultimately leading to enhanced surface coating of model vaccine components (ovalbumin and CpG). Utilizing fluorescent tags and live-animal imaging, we evaluated in vivo cargo retention and bioavailability in mice as a function of route of delivery. Compared with subcutaneous bolus injection of the soluble components, microneedle transdermal delivery not only resulted in enhanced cargo retention in the skin but also improved immune cell activation in the draining lymph nodes. Furthermore, the microneedle vaccine induced a potent humoral immune response, with higher total IgG (Immunoglobulin G) and a more balanced IgG1/IgG2a repertoire and achieved dose sparing. Furthermore, it elicited T cell responses as characterized by functional cytotoxic CD8+ T cells and CD4+ T cells secreting Th1 (T helper type 1)-cytokines. Taken together, CLIP 3D-printed microneedles coated with vaccine components provide a useful platform for a noninvasive, self-applicable vaccination.
Collapse
|
19
|
Jiang Y, Li X, Yu L, Tong W, Chen P, Wang S, Zhao K, Tan X, Gao F, Yu H, Li G, Li L, Zhang Y, van den Born E, Zhou Y, Tong G. Immune efficacy of a candidate porcine reproductive and respiratory syndrome vaccine rHN-NP49 administered by a Needle-free intradermal delivery system in comparison with intramuscular injection. Vaccine 2021; 39:5557-5562. [PMID: 34412921 DOI: 10.1016/j.vaccine.2021.08.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/04/2021] [Accepted: 08/08/2021] [Indexed: 11/25/2022]
Abstract
Porcine reproductive and respiratory syndrome (PRRS) is one of the major drivers of economic loss in the swine industry worldwide. In commercial pig production, vaccination is the first option in an attempt to control infectious diseases. Pigs are therefore often immunized with different vaccines, and almost all of them are delivered via the intramuscular (IM) route. However, the IM injection may result in physical damage, stress reactions, and is labor demanding. An alternative route is urgently needed to reduce the disadvantages of conventional vaccination. In this study, a needle-free intradermal (ID) delivery system was evaluated for delivering a live PRRS vaccine as compared with the traditional needle-syringe method. Fifty-two 4-week-old piglets were divided into six groups: piglets in groups A-C were immunized using ID delivery system with 104, 105 and 106 TCID50 of PRRS candidate vaccine strain rHN-NP49, respectively; piglets in group D were immunized IM with 105 TCID50 of rHN-NP49; and group E and F were used as challenge and control groups, respectively. At 28 days post vaccination, piglets in group A to E were challenged with a lethal dose of highly-pathogenic PRRSV. Similar results were found in viremia and antibody response among the ID and IM groups during the immunization stage. After challenge, similar results were found in average body weight gain, viral shedding, serum viral load, and clinical score among the immunization groups, with a higher protection ratio in the ID group compared with IM group with the same immunization dose. These results demonstrated that the ID delivery system could provide similar or even better protection compared with IM route, and could be an effective route for PRRS vaccination.
Collapse
Affiliation(s)
- Yifeng Jiang
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Xianbin Li
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Lingxue Yu
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Wu Tong
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Pengfei Chen
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Shuaiyong Wang
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Kuan Zhao
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Xiangmei Tan
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Fei Gao
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Hai Yu
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Guoxin Li
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Liwei Li
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | - Yujiao Zhang
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China
| | | | - Yanjun Zhou
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China.
| | - Guangzhi Tong
- Department of Swine Infectious Diseases, Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Shanghai 200241, PR China; Jiangsu Co-Innovation Center for the Prevention and Control of Important Animal Infectious Disease and Zoonosis Yangzhou University, Yangzhou 225009, PR China.
| |
Collapse
|
20
|
Cryomicroneedles for transdermal cell delivery. Nat Biomed Eng 2021; 5:1008-1018. [PMID: 33941895 DOI: 10.1038/s41551-021-00720-1] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Accepted: 03/26/2021] [Indexed: 02/01/2023]
Abstract
Cell therapies for the treatment of skin disorders could benefit from simple, safe and efficient technology for the transdermal delivery of therapeutic cells. Conventional cell delivery by hypodermic-needle injection is associated with poor patient compliance, requires trained personnel, generates waste and has non-negligible risks of injury and infection. Here, we report the design and proof-of-concept application of cryogenic microneedle patches for the transdermal delivery of living cells. The microneedles are fabricated by stepwise cryogenic micromoulding of cryogenic medium with pre-suspended cells, and can be easily inserted into porcine skin and dissolve after deployment of the cells. In mice, cells delivered by the cryomicroneedles retained their viability and proliferative capability. In mice with subcutaneous melanoma tumours, the delivery of ovalbumin-pulsed dendritic cells via the cryomicroneedles elicited higher antigen-specific immune responses and led to slower tumour growth than intravenous and subcutaneous injections of the cells. Biocompatible cryomicroneedles may facilitate minimally invasive cell delivery for a range of cell therapies.
Collapse
|
21
|
Rosenbaum P, Tchitchek N, Joly C, Rodriguez Pozo A, Stimmer L, Langlois S, Hocini H, Gosse L, Pejoski D, Cosma A, Beignon AS, Dereuddre-Bosquet N, Levy Y, Le Grand R, Martinon F. Vaccine Inoculation Route Modulates Early Immunity and Consequently Antigen-Specific Immune Response. Front Immunol 2021; 12:645210. [PMID: 33959127 PMCID: PMC8093451 DOI: 10.3389/fimmu.2021.645210] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 04/06/2021] [Indexed: 01/12/2023] Open
Abstract
Vaccination is one of the most efficient public healthcare measures to fight infectious diseases. Nevertheless, the immune mechanisms induced in vivo by vaccination are still unclear. The route of administration, an important vaccination parameter, can substantially modify the quality of the response. How the route of administration affects the generation and profile of immune responses is of major interest. Here, we aimed to extensively characterize the profiles of the innate and adaptive response to vaccination induced after intradermal, subcutaneous, or intramuscular administration with a modified vaccinia virus Ankara model vaccine in non-human primates. The adaptive response following subcutaneous immunization was clearly different from that following intradermal or intramuscular immunization. The subcutaneous route induced a higher level of neutralizing antibodies than the intradermal and intramuscular vaccination routes. In contrast, polyfunctional CD8+ T-cell responses were preferentially induced after intradermal or intramuscular injection. We observed the same dichotomy when analyzing the early molecular and cellular immune events, highlighting the recruitment of cell populations, such as CD8+ T lymphocytes and myeloid-derived suppressive cells, and the activation of key immunomodulatory gene pathways. These results demonstrate that the quality of the vaccine response induced by an attenuated vaccine is shaped by early and subtle modifications of the innate immune response. In this immunization context, the route of administration must be tailored to the desired type of protective immune response. This will be achieved through systems vaccinology and mathematical modeling, which will be critical for predicting the efficacy of the vaccination route for personalized medicine.
Collapse
Affiliation(s)
- Pierre Rosenbaum
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Nicolas Tchitchek
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Candie Joly
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - André Rodriguez Pozo
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Lev Stimmer
- INSERM, U1169, Kremlin-Bicêtre, France
- CEA – INSERM, MIRCen, UMS27, Fontenay-aux-Roses, France
| | - Sébastien Langlois
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Hakim Hocini
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
- INSERM, U955, Team 16, Clinical and Infectious Diseases Department, Hospital Henri Mondor, University of Paris East, Créteil, France
| | - Leslie Gosse
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - David Pejoski
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Antonio Cosma
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Anne-Sophie Beignon
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Nathalie Dereuddre-Bosquet
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Yves Levy
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
- INSERM, U955, Team 16, Clinical and Infectious Diseases Department, Hospital Henri Mondor, University of Paris East, Créteil, France
| | - Roger Le Grand
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| | - Frédéric Martinon
- UMR1184 IMVA-HB, IDMIT Department, Université Paris-Saclay – INSERM U1184 – CEA, Fontenay-aux-Roses, France
- Vaccine Research Institute, Henri Mondor Hospital, Créteil, France
| |
Collapse
|
22
|
Menon I, Bagwe P, Gomes KB, Bajaj L, Gala R, Uddin MN, D’Souza MJ, Zughaier SM. Microneedles: A New Generation Vaccine Delivery System. MICROMACHINES 2021; 12:435. [PMID: 33919925 PMCID: PMC8070939 DOI: 10.3390/mi12040435] [Citation(s) in RCA: 78] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/30/2021] [Accepted: 04/02/2021] [Indexed: 12/17/2022]
Abstract
Transdermal vaccination route using biodegradable microneedles is a rapidly progressing field of research and applications. The fear of painful needles is one of the primary reasons most people avoid getting vaccinated. Therefore, developing an alternative pain-free method of vaccination using microneedles has been a significant research area. Microneedles comprise arrays of micron-sized needles that offer a pain-free method of delivering actives across the skin. Apart from being pain-free, microneedles provide various advantages over conventional vaccination routes such as intramuscular and subcutaneous. Microneedle vaccines induce a robust immune response as the needles ranging from 50 to 900 μm in length can efficiently deliver the vaccine to the epidermis and the dermis region, which contains many Langerhans and dendritic cells. The microneedle array looks like band-aid patches and offers the advantages of avoiding cold-chain storage and self-administration flexibility. The slow release of vaccine antigens is an important advantage of using microneedles. The vaccine antigens in the microneedles can be in solution or suspension form, encapsulated in nano or microparticles, and nucleic acid-based. The use of microneedles to deliver particle-based vaccines is gaining importance because of the combined advantages of particulate vaccine and pain-free immunization. The future of microneedle-based vaccines looks promising however, addressing some limitations such as dosing inadequacy, stability and sterility will lead to successful use of microneedles for vaccine delivery. This review illustrates the recent research in the field of microneedle-based vaccination.
Collapse
Affiliation(s)
- Ipshita Menon
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Priyal Bagwe
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Keegan Braz Gomes
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Lotika Bajaj
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Rikhav Gala
- Biotechnology Division, Center for Mid-Atlantic (CMA), Fraunhofer USA, Newark, DE 19711, USA;
| | - Mohammad N. Uddin
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Martin J. D’Souza
- Vaccine Nanotechnology Laboratory, Center for Drug Delivery Research, College of Pharmacy, Mercer University, Atlanta, GA 30341, USA; (I.M.); (P.B.); (K.B.G.); (L.B.); (M.N.U.); (M.J.D.)
| | - Susu M. Zughaier
- College of Medicine, QU Health, Qatar University, Doha P.O. Box 2731, Qatar
- Biomedical and Pharmaceutical Research Unit, QU Health, Qatar University, Doha P.O. Box 2731, Qatar
| |
Collapse
|
23
|
Characterization of microneedles and microchannels for enhanced transdermal drug delivery. Ther Deliv 2021; 12:77-103. [DOI: 10.4155/tde-2020-0096] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Microneedle (MN)-based technologies are currently one of the most innovative approaches that are being extensively investigated for transdermal delivery of low molecular weight drugs, biotherapeutic agents and vaccines. Extensive research reports, describing the fabrication and applications of different types of MNs, can be readily found in the literature. Effective characterization tools to evaluate the quality and performance of the MNs as well as for determination of the dimensional and kinetic properties of the microchannels created in the skin, are an essential and critical part of MN-based research. This review paper provides a comprehensive account of all such tools and techniques.
Collapse
|
24
|
Woodley WD, Yue W, Morel DR, Lainesse A, Pettis RJ, Bolick NG. Clinical Evaluation of an Investigational 5 mL Wearable Injector in Healthy Human Subjects. Clin Transl Sci 2020; 14:859-869. [PMID: 33278331 PMCID: PMC8212760 DOI: 10.1111/cts.12946] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 11/09/2020] [Indexed: 11/26/2022] Open
Abstract
An investigational wearable injector (WI), the BD Libertas Wearable Injector (BD Libertas is a trademark of Becton, Dickinson and Company), was evaluated in an early feasibility clinical study for functional performance, tissue effects, subject tolerability, and acceptability of 5 mL, non‐Newtonian ~ 8 cP subcutaneous placebo injections in 52 healthy adult subjects of 2 age groups (18–64 years and ≥ 65 years). Randomized WI subcutaneous injections (n = 208, 4/subject) were delivered to the right and left abdomen and thigh of each subject, 50% (1 thigh and 1 abdomen) with a defined movement sequence during injection. Injector functional performance was documented. Deposition was qualified and quantified with ultrasound. Tissue effects and tolerability (pain) were monitored through 24 hours with corresponding acceptability questionnaires administered through 72 hours. WI (n = 205) automatically inserted the needle, delivered 5 mL ± 5% in 5.42 minutes (SD 0.74) and retracted. Depots were entirely (93.2%) or predominantly (5.4%) localized within the target subcutaneous tissue. Slight to moderate wheals (63.9%) and erythema (75.1%) were observed with ≥ 50% resolution within 30–60 minutes. Subject pain (100 mm Visual Analog Scale) peaked mid‐injection (mean 9.1 mm, SD 13.4) and rapidly resolved within 30 minutes (mean 0.4 mm, SD 2.6). Subjects’ peak pain (≥ 90.2%), injection site appearance (≥ 92.2%) and injector wear, size, and removal (≥ 92.1%) were acceptable (Likert responses) with 100% likely to use the injector if prescribed. Injection site preference was divided between none (46%), abdomen (25%), or thigh (26.9%). The investigational WI successfully delivered 5 mL viscous subcutaneous injections. Tissue effects and pain were transient, well‐tolerated and acceptable. Neither injection site, movement or subject age affected injector functional performance or subject pain and acceptability.
Collapse
Affiliation(s)
- Wendy D Woodley
- BD Technologies & Innovation, Research Triangle Park, North Carolina, USA
| | - Wen Yue
- BD, Franklin Lakes, New Jersey, USA
| | | | | | - Ronald J Pettis
- BD Technologies & Innovation, Research Triangle Park, North Carolina, USA
| | - Natasha G Bolick
- BD Technologies & Innovation, Research Triangle Park, North Carolina, USA
| |
Collapse
|
25
|
Li Z, Biswas A, Finkelstein J, Grein S, Kapoor Y, Milewski M, Queisser G. Modeling Drug Absorption from the Dermis after an Injection. J Pharm Sci 2020; 110:1279-1291.e1. [PMID: 33248056 DOI: 10.1016/j.xphs.2020.10.042] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/16/2020] [Accepted: 10/16/2020] [Indexed: 11/19/2022]
Abstract
A dermal absorption model for small and macromolecules was previously proposed by Ibrahim et al. This model estimated absorption of therapeutics from the dermal tissue based on their molecular size and protein binding through blood and lymphatics. Blood absorption followed a two-pore theory and the lymphatic absorption was limited by the constant lymphatic flow rate. Current work builds on this steady-state concept by modeling the absorption from the dermis immediately after an injection is given (unsteady state). An injection in the dermis creates a localized pressure gradient which resolves itself over time. This phenomenon is captured in the model to estimate the impact of injection volume on the absorption rate constant. Blood absorption follows the two-pore theory but is time-dependent and the lymphatic absorption is determined based on valve opening and pressure driven convective flow, returning to steady-state as the molecule is absorbed. A direct comparison of the steady-state analysis, experimental data and the current model is made. The results indicate that accounting for the localized time-varying pressure can better predict the experimental absorption rate constants. This work significantly improves the existing understanding of macromolecule uptake from the interstitial fluid following intradermal injection.
Collapse
Affiliation(s)
- Zhi Li
- Temple University, Department of Mathematics, 1805 N Broad Street, Philadelphia, PA 19122, USA
| | - Abhijit Biswas
- Temple University, Department of Mathematics, 1805 N Broad Street, Philadelphia, PA 19122, USA
| | - Joshua Finkelstein
- Temple University, Department of Mathematics, 1805 N Broad Street, Philadelphia, PA 19122, USA
| | - Stephan Grein
- Temple University, Department of Mathematics, 1805 N Broad Street, Philadelphia, PA 19122, USA
| | - Yash Kapoor
- Merck Research Laboratories, Merck & Co., Inc., Kenilworth, NJ, 07033, USA.
| | - Mikolaj Milewski
- Merck Research Laboratories, Merck & Co., Inc., Kenilworth, NJ, 07033, USA.
| | - Gillian Queisser
- Temple University, Department of Mathematics, 1805 N Broad Street, Philadelphia, PA 19122, USA.
| |
Collapse
|
26
|
Tucak A, Sirbubalo M, Hindija L, Rahić O, Hadžiabdić J, Muhamedagić K, Čekić A, Vranić E. Microneedles: Characteristics, Materials, Production Methods and Commercial Development. MICROMACHINES 2020; 11:mi11110961. [PMID: 33121041 PMCID: PMC7694032 DOI: 10.3390/mi11110961] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 10/24/2020] [Accepted: 10/25/2020] [Indexed: 01/19/2023]
Abstract
Although transdermal drug delivery systems (DDS) offer numerous benefits for patients, including the avoidance of both gastric irritation and first-pass metabolism effect, as well as improved patient compliance, only a limited number of active pharmaceutical ingredients (APIs) can be delivered accordingly. Microneedles (MNs) represent one of the most promising concepts for effective transdermal drug delivery that penetrate the protective skin barrier in a minimally invasive and painless manner. The first MNs were produced in the 90s, and since then, this field has been continually evolving. Therefore, different manufacturing methods, not only for MNs but also MN molds, are introduced, which allows for the cost-effective production of MNs for drug and vaccine delivery and even diagnostic/monitoring purposes. The focus of this review is to give a brief overview of MN characteristics, material composition, as well as the production and commercial development of MN-based systems.
Collapse
Affiliation(s)
- Amina Tucak
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
- Correspondence: (A.T.); (E.V.)
| | - Merima Sirbubalo
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
| | - Lamija Hindija
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
| | - Ognjenka Rahić
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
| | - Jasmina Hadžiabdić
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
| | - Kenan Muhamedagić
- Department of Machinery Production Engineering, Faculty of Mechanical Engineering, University of Sarajevo, Vilsonovo šetalište 9, 71000 Sarajevo, Bosnia and Herzegovina; (K.M.); (A.Č.)
| | - Ahmet Čekić
- Department of Machinery Production Engineering, Faculty of Mechanical Engineering, University of Sarajevo, Vilsonovo šetalište 9, 71000 Sarajevo, Bosnia and Herzegovina; (K.M.); (A.Č.)
| | - Edina Vranić
- Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Sarajevo, Zmaja od Bosne 8, 71000 Sarajevo, Bosnia and Herzegovina; (M.S.); (L.H.); (O.R.); (J.H.)
- Correspondence: (A.T.); (E.V.)
| |
Collapse
|
27
|
Akhtar N, Singh V, Yusuf M, Khan RA. Non-invasive drug delivery technology: development and current status of transdermal drug delivery devices, techniques and biomedical applications. ACTA ACUST UNITED AC 2020; 65:243-272. [PMID: 31926064 DOI: 10.1515/bmt-2019-0019] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 08/30/2019] [Indexed: 12/25/2022]
Abstract
Pay-load deliveries across the skin barrier to the systemic circulation have been one of the most challenging delivery options. Necessitated requirements of the skin and facilitated skin layer cross-over delivery attempts have resulted in development of different non-invasive, non-oral methods, devices and systems which have been standardized, concurrently used and are in continuous upgrade and improvements. Iontophoresis, electroporation, sonophoresis, magnetophoresis, dermal patches, nanocarriers, needled and needle-less shots, and injectors are among some of the methods of transdermal delivery. The current review covers the current state of the art, merits and shortcomings of the systems, devices and transdermal delivery patches, including drugs' and other payloads' passage facilitation techniques, permeation and absorption feasibility studies, as well as physicochemical properties affecting the delivery through different transdermal modes along with examples of drugs, vaccines, genes and other payloads.
Collapse
Affiliation(s)
- Naseem Akhtar
- Department of Pharmaceutics, College of Pharmacy,Buraydah Colleges, PO Box 31717, Qassim 51418, Saudi Arabia
| | - Varsha Singh
- Manav Rachna International University (MRIU) and Manav Rachna International Institute of Research and Study (MRIIRS), Faridabad, HR 121 001, India
| | - Mohammad Yusuf
- College of Pharmacy, University of Taif, Taif Al-Haweiah, Taif, Saudi Arabia.https://orcid.org/0000-0003- 1417-7774
| | - Riaz A Khan
- Manav Rachna International University (MRIU) and Manav Rachna International Institute of Research and Study (MRIIRS), Faridabad, HR 121 001, India.,Department of Medicinal Chemistry, College of Pharmacy, Qassim University, Qassim 51452, Saudi Arabia
| |
Collapse
|
28
|
Saitoh A, Nirei J, Tanaka T, Haniu H, Sakai T, Okubo S, Hirano H. Skin thickness in neonates: Implications for intradermal vaccination. Vaccine 2020; 38:5659-5664. [PMID: 32654901 DOI: 10.1016/j.vaccine.2020.06.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 06/19/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Intradermal (ID) injection is an alternate route that enhances vaccine immunogenicity and decreases vaccine dose. Regular immunization usually starts at age 2 months, and the limited immune capacity of neonates and young infants makes them vulnerable to infection. Successful ID vaccine delivery in this population requires knowledge of skin thickness. Although skin thickness has been evaluated in infants aged 2 months or older, no comparable data are available for neonates, including preterm neonates. METHODS This prospective observational study used ultrasonography to assess skin thickness in 70 neonates (35 full-term and 35 preterm neonates) at deltoid, suprascapular, and thigh sites. The measurements were compared in relation to anatomical site, between full-term and preterm infants, and with skin thickness values for children aged 2 months or older, which were collected in our previous study using the same measurement technique. RESULTS In full-term neonates, skin was significantly thicker at the suprascapular site than at the deltoid and thigh sites (P < 0.05); in preterm neonates, skin was significantly thicker at the suprascapular site than at the thigh site (P < 0.05). Skin thickness values at all three sites were significantly lower in preterm neonates than in full-term neonates (P < 0.05). As compared with skin thickness values for infants aged 2 months, values for full-term neonates were significantly lower for the deltoid and suprascapular sites (P < 0.001). CONCLUSIONS Skin thickness values for neonates were affected by prematurity and were significantly lower than those for infants aged 2 months. These findings are important in the design of ID injection devices for neonates and young infants.
Collapse
Affiliation(s)
- Akihiko Saitoh
- Department of Pediatrics, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
| | - Jun Nirei
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| | - Takeshi Tanaka
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| | - Hisanori Haniu
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| | - Takatsugu Sakai
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| | - Soichiro Okubo
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| | - Harunobu Hirano
- Department of Pediatrics, Saiseikai Niigata Hospital, Niigata, Japan
| |
Collapse
|
29
|
Liu Y, Wen Z, Carrion R, Nunneley J, Staples H, Ticer A, Patterson JL, Compans RW, Ye L, Yang C. Intradermal Immunization of EBOV VLPs in Guinea Pigs Induces Broader Antibody Responses Against GP Than Intramuscular Injection. Front Microbiol 2020; 11:304. [PMID: 32174901 PMCID: PMC7056717 DOI: 10.3389/fmicb.2020.00304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Accepted: 02/11/2020] [Indexed: 11/20/2022] Open
Abstract
Ebolavirus (EBOV) infection in humans causes severe hemorrhagic fevers with high mortality rates that range from 30 to 80% as shown in different outbreaks. Thus the development of safe and efficacious EBOV vaccines remains an important goal for biomedical research. We have shown in early studies that immunization with insect cell-produced EBOV virus-like particles (VLPs) is able to induce protect vaccinated mice against lethal EBOV challenge. In the present study, we investigated immune responses induced by Ebola VLPs via two different routes, intramuscular and intradermal immunizations, in guinea pigs. Analyses of antibody responses revealed that similar levels of total IgG antibodies against the EBOV glycoprotein (GP) were induced by the two different immunization methods. However, further characterization showed that the EBOV GP-specific antibodies induced by intramuscular immunization were mainly of the IgG2 subtype whereas both IgG1 and IgG2 antibodies against EBOV GP were induced by intradermal immunization. In contrast, antibody responses against the EBOV matrix protein VP40 induced by intramuscular or intradermal immunizations exhibited similar IgG1 and IgG2 profiles. More interestingly, we found that the sites that the IgG1 antibodies induced by intradermal immunizations bind to in GP are different from those that bind to the IgG2 antibodies induced by intramuscular immunization. Further analyses revealed that sera from all vaccinated guinea pigs exhibited neutralizing activity against Ebola GP-mediated HIV pseudovirion infection at high levels. Moreover, all EBOV VLP-vaccinated guinea pigs survived the challenge by a high dose (1000 pfu) of guinea pig-adapted EBOV, while all control guinea pigs immunized with irrelevant VLPs succumbed to the challenge. The induction of both IgG1 and IgG2 antibody responses that recognized broader sites in GP by intradermal immunization of EBOV VLPs indicates that this approach may represent a more advantageous route of vaccination against virus infection.
Collapse
Affiliation(s)
- Ying Liu
- State Key Laboratory of Food Nutrition and Safety, Institute of Health Biotechnology, College of Biotechnology, Tianjin University of Science and Technology, Tianjin, China
- Department of Microbiology and Immunology and Emory Vaccine Center, School of Medicine, Emory University, Atlanta, GA, United States
| | - Zhiyuan Wen
- Department of Microbiology and Immunology and Emory Vaccine Center, School of Medicine, Emory University, Atlanta, GA, United States
- Harbin Veterinary Research Institute, Harbin, China
| | - Ricardo Carrion
- Texas Biomedical Research Institute, San Antonio, TX, United States
| | - Jerritt Nunneley
- Texas Biomedical Research Institute, San Antonio, TX, United States
| | - Hilary Staples
- Texas Biomedical Research Institute, San Antonio, TX, United States
| | - Anysha Ticer
- Texas Biomedical Research Institute, San Antonio, TX, United States
| | | | - Richard W. Compans
- Department of Microbiology and Immunology and Emory Vaccine Center, School of Medicine, Emory University, Atlanta, GA, United States
| | - Ling Ye
- Department of Microbiology and Immunology and Emory Vaccine Center, School of Medicine, Emory University, Atlanta, GA, United States
| | - Chinglai Yang
- Department of Microbiology and Immunology and Emory Vaccine Center, School of Medicine, Emory University, Atlanta, GA, United States
| |
Collapse
|
30
|
Balmert SC, Carey CD, Falo GD, Sethi SK, Erdos G, Korkmaz E, Falo LD. Dissolving undercut microneedle arrays for multicomponent cutaneous vaccination. J Control Release 2020; 317:336-346. [PMID: 31756393 PMCID: PMC8237702 DOI: 10.1016/j.jconrel.2019.11.023] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/08/2019] [Accepted: 11/18/2019] [Indexed: 01/21/2023]
Abstract
The skin is an attractive tissue target for vaccination, as it is readily accessible and contains a dense population of antigen-presenting and immune-accessory cells. Microneedle arrays (MNAs) are emerging as an effective tool for in situ engineering of the cutaneous microenvironment to enable diverse immunization strategies. Here, we present novel dissolving undercut MNAs and demonstrate their application for effective multicomponent cutaneous vaccination. The MNAs are composed of micron-scale needles featuring pyramidal heads supported by undercut stem regions with filleted bases to ensure successful skin penetration and retention during application. Prior efforts to fabricate dissolving undercut microstructures were limited and required complex and lengthy processing and assembly steps. In the current study, we strategically combine three-dimensional (3D) laser lithography, an emerging micro-additive manufacturing method with unique geometric capabilities and nanoscale resolution, and micromolding with favorable materials. This approach enables reproducible production of dissolving MNAs with undercut microneedles that can be tip-loaded with multiple biocargos, such as antigen (ovalbumin) and adjuvant (Poly(I:C)). The resulting MNAs fulfill the geometric (sharp tips and smooth edges) and mechanical-strength requirements for failure-free penetration of human and murine skin to simultaneously deliver multicomponent (antigen plus adjuvant) vaccines to the same cutaneous microenvironment. Cutaneous vaccination of mice using these MNAs induces more potent antigen-specific cellular and humoral immune responses than those elicited by traditional intramuscular injection. Together, the unique geometric features of these undercut MNAs and the associated manufacturing strategy, which is compatible with diverse drugs and biologics, could enable a broad range of non-cutaneous and cutaneous drug delivery applications, including multicomponent vaccination.
Collapse
Affiliation(s)
- Stephen C Balmert
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States
| | - Cara Donahue Carey
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States
| | - Gabriel D Falo
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States
| | - Shiv K Sethi
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States
| | - Geza Erdos
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States
| | - Emrullah Korkmaz
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States.
| | - Louis D Falo
- Department of Dermatology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, United States; Department of Bioengineering, University of Pittsburgh Swanson School of Engineering, Pittsburgh, PA 15261, United States; Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, PA 15213, United States; UPMC Hillman Cancer Center, Pittsburgh, PA 15232, United States; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, United States.
| |
Collapse
|
31
|
Abstract
Under many circumstances, prophylactic immunizations are considered as the only possible strategy to control infectious diseases. Considerable efforts are typically invested in immunogen selection but, erroneously, the route of administration is not usually a major concern despite the fact that it can strongly influence efficacy. The skin is now considered a key component of the lymphatic system with tremendous potential as a target for vaccination. The purpose of this review is to present the immunological basis of the skin-associated lymphoid tissue, so as to provide understanding of the skin vaccination strategies. Several strategies are currently being developed for the transcutaneous delivery of antigens. The classical, mechanical or chemical disruptions versus the newest approaches based on microneedles for antigen delivery through the skin are discussed herein.
Collapse
|
32
|
Lee K, Goudie MJ, Tebon P, Sun W, Luo Z, Lee J, Zhang S, Fetah K, Kim HJ, Xue Y, Darabi MA, Ahadian S, Sarikhani E, Ryu W, Gu Z, Weiss PS, Dokmeci MR, Ashammakhi N, Khademhosseini A. Non-transdermal microneedles for advanced drug delivery. Adv Drug Deliv Rev 2019; 165-166:41-59. [PMID: 31837356 PMCID: PMC7295684 DOI: 10.1016/j.addr.2019.11.010] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 11/21/2019] [Accepted: 11/25/2019] [Indexed: 12/21/2022]
Abstract
Microneedles (MNs) have been used to deliver drugs for over two decades. These platforms have been proven to increase transdermal drug delivery efficiency dramatically by penetrating restrictive tissue barriers in a minimally invasive manner. While much of the early development of MNs focused on transdermal drug delivery, this technology can be applied to a variety of other non-transdermal biomedical applications. Several variations, such as multi-layer or hollow MNs, have been developed to cater to the needs of specific applications. The heterogeneity in the design of MNs has demanded similar variety in their fabrication methods; the most common methods include micromolding and drawing lithography. Numerous materials have been explored for MN fabrication which range from biocompatible ceramics and metals to natural and synthetic biodegradable polymers. Recent advances in MN engineering have diversified MNs to include unique shapes, materials, and mechanical properties that can be tailored for organ-specific applications. In this review, we discuss the design and creation of modern MNs that aim to surpass the biological barriers of non-transdermal drug delivery in ocular, vascular, oral, and mucosal tissue.
Collapse
Affiliation(s)
- KangJu Lee
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Marcus J Goudie
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Peyton Tebon
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Wujin Sun
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Zhimin Luo
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Junmin Lee
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Shiming Zhang
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Kirsten Fetah
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Han-Jun Kim
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Yumeng Xue
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Mohammad Ali Darabi
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Samad Ahadian
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Einollah Sarikhani
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - WonHyoung Ryu
- Department of Mechanical Engineering, Yonsei University, Seoul 03722, South Korea
| | - Zhen Gu
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, Los Angeles, CA 90024, USA; Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Raleigh, NC 27695, USA
| | - Paul S Weiss
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA; Department of Chemistry and Biochemistry, Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Mehmet R Dokmeci
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA; Department of Radiology, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Nureddin Ashammakhi
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA; Department of Radiology, University of California, Los Angeles, Los Angeles, CA 90095, USA.
| | - Ali Khademhosseini
- Department of Bioengineering and Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA 90095, USA; California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, Los Angeles, CA 90024, USA; Department of Radiology, University of California, Los Angeles, Los Angeles, CA 90095, USA; Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, CA 90095, USA.
| |
Collapse
|
33
|
Ranamukhaarachchi SA, Esposito TV, Raeiszadeh M, Häfeli UO, Stoeber B. Precise measurement of intradermal fluid delivery using a low activity technetium-99m pertechnetate tracer. Vaccine 2019; 37:7463-7469. [PMID: 31587894 DOI: 10.1016/j.vaccine.2019.09.078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 09/17/2019] [Accepted: 09/24/2019] [Indexed: 11/26/2022]
Abstract
A method was developed and validated to determine the intradermal (ID) fluid delivery potential of several ID devices, including hollow microneedles. The novel method used water soluble technetium-99 m pertechnetate (99mTcO4-) diluted in normal saline to measure the volume of fluid delivered to and remaining in the skin. The fluid that back-flowed to the skin surface and the fluid left on the device surface were also quantified, thus capturing all fluid volumes deposited during intradermal injections. The technique described in this manuscript was used to assess the injection performance of conventional hypodermic needles and hollow microneedles ex vivo using porcine skin and in vivo with a rat model. Since only a small fraction, 1.1%, of the water-soluble tracer remained bound to the skin when applied topically, the technique can be used to differentiate between injected fluid and backflow. Counting of gamma radiation from 99mTcO4- provided sub-nanoliter resolution for volume measurements, making the proposed method powerful, sensitive, and suitable for the assessments of ID injection devices, particularly for vaccine delivery.
Collapse
Affiliation(s)
- Sahan A Ranamukhaarachchi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada; Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Tullio V Esposito
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Mehrsa Raeiszadeh
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
| | - Urs O Häfeli
- Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Boris Stoeber
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada; Department of Mechanical Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
| |
Collapse
|
34
|
Etra JW, Grzelak MJ, Fidder SA, Kolegraff K, Bonawitz S, Shores J, Oh B, Cooney DS, Beck SE, Brandacher G. A Skin Rejection Grading System for Vascularized Composite Allotransplantation in a Preclinical Large Animal Model. Transplantation 2019; 103:1385-1391. [PMID: 31241555 PMCID: PMC6613727 DOI: 10.1097/tp.0000000000002695] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 02/13/2019] [Accepted: 02/14/2019] [Indexed: 11/25/2022]
Abstract
BACKGROUND The Banff Criteria have been accepted as a system for grading histological rejection in graft skin in human vascularized composite allotransplantation (VCA). Preclinical swine hindlimb transplantation models have an important role in translational studies in VCA. However, unified grading criteria for rejection in swine skin have not yet been established. METHODS Two hundred fourteen swine skin biopsy specimens were reviewed, including 88 native skin biopsies and 126 specimens from the skin component of heterotopic swine hindlimb transplants. Thorough review was performed in a blinded fashion by an expert veterinary pathologist with attention paid to the applicability of the Banff criteria as well as specific histologic characteristics and trends. Clinical and histopathologic rejection scores were then directly compared. RESULTS Two hundred fourteen specimens reviewed showed significant similarities between swine and human skin, as previously published. Notable swine-specific characteristics, including paucicellular infiltration with rare epidermal cell infiltration or necrosis, were accounted for in a proposed grading system that parallels the Banff Criteria. CONCLUSIONS This comprehensive grading system, based on the Banff Classification for skin rejection in VCA, provides a standardized system for more accurate comparison of rejection in preclinical swine VCA models.
Collapse
Affiliation(s)
- Joanna W. Etra
- Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Michael J. Grzelak
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
- Johns Hopkins University School of Medicine, Baltimore, MD
| | - Samuel A.J. Fidder
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Keli Kolegraff
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Steven Bonawitz
- Department of Surgery, Cooper Medical School of Rowan University, Camden, NJ
| | - Jaimie Shores
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Byoungchol Oh
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Damon S. Cooney
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Sarah E. Beck
- Department of Molecular and Comparative Pathobiology, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Gerald Brandacher
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Johns Hopkins University School of Medicine, Baltimore, MD
| |
Collapse
|
35
|
Cheng H, Liu M, Du X, Xu J, Zhai Y, Ji J, He S, Zhai G. Recent progress of micro-needle formulations: Fabrication strategies and delivery applications. J Drug Deliv Sci Technol 2019. [DOI: 10.1016/j.jddst.2019.01.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
36
|
Creighton RL, Woodrow KA. Microneedle-Mediated Vaccine Delivery to the Oral Mucosa. Adv Healthc Mater 2019; 8:e1801180. [PMID: 30537400 PMCID: PMC6476557 DOI: 10.1002/adhm.201801180] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 11/12/2018] [Indexed: 12/28/2022]
Abstract
The oral mucosa is a minimally invasive and immunologically rich site that is underutilized for vaccination due to physiological and immunological barriers. To develop effective oral mucosal vaccines, key questions regarding vaccine residence time, uptake, adjuvant formulation, dose, and delivery location must be answered. However, currently available dosage forms are insufficient to address all these questions. An ideal oral mucosal vaccine delivery system would improve both residence time and epithelial permeation while enabling efficient delivery of physicochemically diverse vaccine formulations. Microneedles have demonstrated these capabilities for dermal vaccine delivery. Additionally, microneedles enable precise control over delivery properties like depth, uniformity, and dosing, making them an ideal tool to study oral mucosal vaccination. Select studies have demonstrated the feasibility of microneedle-mediated oral mucosal vaccination, but they have only begun to explore the broad functionality of microneedles. This review describes the physiological and immunological challenges related to oral mucosal vaccine delivery and provides specific examples of how microneedles can be used to address these challenges. It summarizes and compares the few existing oral mucosal microneedle vaccine studies and offers a perspective for the future of the field.
Collapse
Affiliation(s)
- Rachel L Creighton
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Kim A Woodrow
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| |
Collapse
|
37
|
Shrestha P, Stoeber B. Fluid absorption by skin tissue during intradermal injections through hollow microneedles. Sci Rep 2018; 8:13749. [PMID: 30213982 PMCID: PMC6137045 DOI: 10.1038/s41598-018-32026-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 08/31/2018] [Indexed: 12/16/2022] Open
Abstract
Hollow microneedles are an emerging technology for delivering drugs and therapeutics, such as vaccines and insulin, into the skin. Although the benefits of intradermal drug delivery have been known for decades, our understanding of fluid absorption by skin tissue has been limited due to the difficulties in imaging a highly scattering biological material such as skin. Here, we report the first real-time imaging of skin tissue at the microscale during intradermal injections through hollow microneedles, using optical coherence tomography. We show that skin tissue behaves like a deformable porous medium and absorbs fluid by locally expanding rather than rupturing to form a single fluid filled cavity. We measure the strain distribution in a cross section of the tissue to quantify local tissue deformation, and find that the amount of volumetric expansion of the tissue corresponds closely to the volume of fluid injected. Mechanically restricting tissue expansion limits fluid absorption into the tissue. Our experimental findings can provide insights to optimize the delivery of drugs into skin for different therapeutic applications, and to better model fluid flow into biological tissue.
Collapse
Affiliation(s)
- Pranav Shrestha
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada
| | - Boris Stoeber
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada. .,Department of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver, British Columbia, V6T 1Z4, Canada.
| |
Collapse
|
38
|
Leoni G, Lyness A, Ginty P, Schutte R, Pillai G, Sharma G, Kemp P, Mount N, Sharpe M. Preclinical development of an automated injection device for intradermal delivery of a cell-based therapy. Drug Deliv Transl Res 2018; 7:695-708. [PMID: 28812281 PMCID: PMC5574955 DOI: 10.1007/s13346-017-0418-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Current methods for intradermal delivery of therapeutic products in clinical use include manual injection via the Mantoux technique and the use of injection devices, primarily developed for the delivery of vaccines and small molecules. A novel automated injection device is presented specifically designed for accurate delivery of multiple doses of product through a number of adjustable injection parameters, including injection depth, dose volume and needle insertion speed. The device was originally conceived for the delivery of a cell-based therapy to patients with skin wounds caused by epidermolysis bullosa. A series of preclinical studies was conducted (i) to evaluate the performance of the pre-production model (PreCTCDV01) and optimise the final design, (ii) to confirm that a cell therapy product can be effectively delivered through the injection system and (iii) to test whether the device can be safely and effectively operated by potential end-users. Results from these studies confirmed that the device is able to consistently deliver repeated doses of a liquid to the intradermal layer in an ex vivo skin model. In addition, the device can support delivery of a cell therapy product through a customised microbore tubing without compromising cell viability. Finally, the device was shown to be safe and easy to use as evidenced by usability testing. The clinical device has since been granted European market access and plans for clinical use are currently underway. The device is expected to find use in the emerging area of cell therapies and a broad spectrum of traditional parenteral drug delivery applications.
Collapse
Affiliation(s)
- Giulia Leoni
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Alex Lyness
- Centre for Biological Engineering, Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Leicestershire, LE11 3TU, UK
| | - Patrick Ginty
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Rindi Schutte
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Gopalan Pillai
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Gayatri Sharma
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Paul Kemp
- Intercytex Ltd, 5 Vale Road, Stockport, SK6 3LE, UK
| | - Natalie Mount
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK
| | - Michaela Sharpe
- Cell and Gene Therapy Catapult, 12th Floor Tower Wing, Guys Hospital, Great Maze Pond, London, SE1 9RT, UK.
| |
Collapse
|
39
|
Assessment of Forces in Intradermal Injection Devices: Hydrodynamic Versus Human Factors. Pharm Res 2018; 35:120. [PMID: 29671074 DOI: 10.1007/s11095-018-2397-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 03/26/2018] [Indexed: 12/19/2022]
Abstract
PURPOSE The force that has to be exerted on the plunger for administering a given amount of fluid in a given time, has an important influence on comfort for the subject and usability for the administrator in intradermal drug delivery. The purpose of this study is to model those forces that are subject-independent, by linking needle and syringe geometry to the force required for ejecting a given fluid at a given ejection rate. MATERIAL AND METHODS We extend the well-known Hagen-Poiseuille formula to predict pressure drop induced by a fluid passing through a cylindrical body. The model investigates the relation between the pressure drop in needles and the theoretic Hagen-Poiseuille prediction and is validated in fifteen needles from 26G up to 33G suited for intradermal drug delivery. We also provide a method to assess forces exerted by operators in real world conditions. RESULTS The model is highly linear in each individual needle with R-square values ranging from 75% up to 99.9%. Ten out of fifteen needles exhibit R-square values above 99%. A proof-of-concept for force assessment is provided by logging forces in operators in real life conditions. CONCLUSIONS The force assessment method and the model can be used to pinpoint needle geometry for intradermal injection devices, tuning comfort for subjects and usability for operators.
Collapse
|
40
|
Microneedles as the technique of drug delivery enhancement in diverse organs and tissues. J Control Release 2018; 270:184-202. [DOI: 10.1016/j.jconrel.2017.11.048] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Revised: 11/22/2017] [Accepted: 11/29/2017] [Indexed: 11/24/2022]
|
41
|
|
42
|
Vescovo P, Rettby N, Ramaniraka N, Liberman J, Hart K, Cachemaille A, Piveteau LD, Zanoni R, Bart PA, Pantaleo G. Safety, tolerability and efficacy of intradermal rabies immunization with DebioJect™. Vaccine 2017; 35:1782-1788. [PMID: 28317660 DOI: 10.1016/j.vaccine.2016.09.069] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Revised: 09/02/2016] [Accepted: 09/12/2016] [Indexed: 10/19/2022]
Abstract
In a single-center study, 66 healthy volunteers aged between 18 and 50years were randomized to be immunized against rabies with three different injection routes: intradermal with DebioJect™ (IDJ), standard intradermal with classical needle (IDS), also called Mantoux method, and intramuscular with classical needle (IM). "Vaccin rabique Pasteur®" and saline solution (NaCl 0.9%) were administered at D0, D7 and D28. Antigen doses for both intradermal routes were 1/5 of the dose for IM. Tolerability, safety and induced immunogenicity of IDJ were compared to IDS and IM routes. Pain was evaluated at needle insertion and at product injection for all vaccination visits. Solicited Adverse Event (SolAE) and local reactogenicity symptoms including pain, redness and pruritus were recorded daily following each vaccination visit. Adverse events (AE) were recorded over the whole duration of the study. Humoral immune response was measured by assessing the rabies virus neutralizing antibody (VNA) titers using Rapid Fluorescent Focus Inhibition Test (RFFIT). Results demonstrated that the DebioJect™ is a safe, reliable and efficient device. Significant decreases of pain at needle insertion and at vaccine injection were reported with IDJ compared to IDS and IM. All local reactogenicity symptoms (pain, redness and pruritus) after injection with either vaccine or saline solution, were similar for IDJ and IDS, except that IDJ injection induced more redness 30min after saline solution. No systemic SolAE was deemed related to DebioJect™ and classical needles. No AE was deemed related to DebioJect™. No Serious Adverse Event (SAE) was reported during the study. At the end of the study all participants were considered immunized against rabies and no significant difference in humoral response was observed between the 3 studied routes.
Collapse
Affiliation(s)
| | - Nils Rettby
- Vaccine and Immunotherapy Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| | | | - Julie Liberman
- Vaccine and Immunotherapy Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| | - Karen Hart
- Vaccine and Immunotherapy Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| | | | | | - Reto Zanoni
- Institute of Virology and Immunology in cooperation with the Vetsuisse Faculty of the University of Bern, Bern, Switzerland
| | - Pierre-Alexandre Bart
- Vaccine and Immunotherapy Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| | - Giuseppe Pantaleo
- Vaccine and Immunotherapy Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
| |
Collapse
|
43
|
Nguyen TT, Park JH. Human studies with microneedles for evaluation of their efficacy and safety. Expert Opin Drug Deliv 2017; 15:235-245. [PMID: 29169288 DOI: 10.1080/17425247.2018.1410138] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
INTRODUCTION During the past two decades, many studies have documented the development of microneedles (MNs) as a feasible technique for the effective administration of drugs. More and more human studies have been done with MNs to bridge the gap between research and market applications that provide efficacious techniques for clinical implementation. AREAS COVERED The aim of this review is provide a brief description of the status of human study with MNs and to demonstrate progress for the right use of microneedle arrays in clinical settings. It also describes the considerations for clinical application with each type of MNs. EXPERT OPINION Microneedle systems were introduced to overcome the limitations of conventional methods of drug administration. Lots of microneedle systems have undergone clinical evaluation to determine their efficacy and safety, and many studies have demonstrated positive results. The successful clinical use of the microneedle in vaccine therapy is remarkable and supports the importance of conducting further tests in a wide range of medical applications. Self-administered MNs appeared to be an attractive alternative method that needs further research to become a reality in the near future.
Collapse
Affiliation(s)
- Thuy Trang Nguyen
- a Department of BioNano Technology , Gachon University , Gyeonggi-Do , South of Korea
| | - Jung Hwan Park
- a Department of BioNano Technology , Gachon University , Gyeonggi-Do , South of Korea
| |
Collapse
|
44
|
Jonker EFF, Visser LG. Single visit rabies pre-exposure priming induces a robust anamnestic antibody response after simulated post-exposure vaccination: results of a dose-finding study. J Travel Med 2017; 24:3954783. [PMID: 28931127 DOI: 10.1093/jtm/tax033] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2017] [Accepted: 04/10/2017] [Indexed: 12/25/2022]
Abstract
BACKGROUND The current standard 3-dose intramuscular rabies PrEP schedule suffers from a number of disadvantages that severely limit accessibility and availability. The cost of is often prohibitive, it requires 3 visits to the clinic, and there are regular vaccine shortages. METHODS Volunteers ( N = 30) were randomly assigned to 4 study arms: 1 standard dose intramuscular (IM) dose of PVRV (purified Vero cell rabies vaccine, Verorab), and 1/5th, 2/5th or 3/5th- fractional intradermal (ID) dose of PVRV in a single visit. All subjects received a simulated rabies post-exposure prophylaxis (D0, D3) 1 year later. Rabies virus neutralizing antibodies (RVNA) were determined by virus neutralization microtest (FAVN) on D0, D7, D28, Y1 and Y1 + D7. RESULTS 28 out of 30 subjects (93%) seroconverted 1 month after primary vaccination; 1 subject in the 1-dose IM arm and 1 in the 1/5th-fractional dose ID arm did not. After 1 year, 22 out of 30 subjects (73%) no longer had RVNA above 0.5 IU/ml, with no discernible difference between study groups. After 1 year, all 30 subjects mounted a booster response within 7 days after simulated PEP, with the highest titers found in the single dose IM group ( P < 0.03). CONCLUSIONS This dose finding study demonstrates that priming with a single dose of rabies vaccine was sufficient to induce an adequate anamnestic antibody response to rabies PEP in all subjects 1 year later, even in those in whom the RVNA threshold of 0.5 IU/ml was not reached after priming.
Collapse
Affiliation(s)
- Emile F F Jonker
- Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| | - Leonardus G Visser
- Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| |
Collapse
|
45
|
Bhatnagar S, Dave K, Venuganti VVK. Microneedles in the clinic. J Control Release 2017; 260:164-182. [DOI: 10.1016/j.jconrel.2017.05.029] [Citation(s) in RCA: 142] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2017] [Revised: 05/21/2017] [Accepted: 05/23/2017] [Indexed: 12/16/2022]
|
46
|
Nakatsukasa A, Kuruma K, Okamatsu M, Hiono T, Suzuki M, Matsuno K, Kida H, Oyamada T, Sakoda Y. Potency of whole virus particle and split virion vaccines using dissolving microneedle against challenges of H1N1 and H5N1 influenza viruses in mice. Vaccine 2017; 35:2855-2861. [PMID: 28431812 DOI: 10.1016/j.vaccine.2017.04.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2016] [Revised: 03/26/2017] [Accepted: 04/04/2017] [Indexed: 10/19/2022]
Abstract
Transdermal vaccination using a microneedle (MN) confers enhanced immunity compared with subcutaneous (SC) vaccination. Here we developed a novel dissolving MN patch for the influenza vaccine. The potencies of split virion and whole virus particle (WVP) vaccines prepared from A/Puerto Rico/8/1934 (H1N1) and A/duck/Hokkaido/Vac-3/2007 (H5N1), respectively, were evaluated. MN vaccination induced higher neutralizing antibody responses than SC vaccination in mice. Moreover, MN vaccination with a lower dose of antigens conferred protective immunity against lethal challenges of influenza viruses than SC vaccination in mice. These results suggest that the WVP vaccines administered using MN are an effective combination for influenza vaccine to be further validated in humans.
Collapse
Affiliation(s)
- Akihiro Nakatsukasa
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan
| | - Koji Kuruma
- Pharmaceutical & Healthcare Research Laboratories, Research & Development Management Headquarters, FUJIFILM Corporation, Kaisei 258-8577, Japan
| | - Masatoshi Okamatsu
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan
| | - Takahiro Hiono
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan
| | - Mizuho Suzuki
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan
| | - Keita Matsuno
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan; Global Station for Zoonosis Control, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 001-0020, Japan
| | - Hiroshi Kida
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan; Global Station for Zoonosis Control, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 001-0020, Japan; Research Center for Zoonosis Control, Hokkaido University, Sapporo 001-0020, Japan
| | - Takayoshi Oyamada
- Pharmaceutical & Healthcare Research Laboratories, Research & Development Management Headquarters, FUJIFILM Corporation, Kaisei 258-8577, Japan
| | - Yoshihiro Sakoda
- Laboratory of Microbiology, Department of Disease Control, Graduate School of Veterinary Medicine, Hokkaido University, Sapporo 060-0818, Japan; Global Station for Zoonosis Control, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo 001-0020, Japan.
| |
Collapse
|
47
|
Jarrahian C, Rein-Weston A, Saxon G, Creelman B, Kachmarik G, Anand A, Zehrung D. Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV). Vaccine 2017; 35:1789-1796. [PMID: 28189403 PMCID: PMC6381447 DOI: 10.1016/j.vaccine.2016.11.098] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 11/15/2016] [Accepted: 11/29/2016] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. METHODS Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. RESULTS Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. DISCUSSION If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered.
Collapse
Affiliation(s)
| | | | - Gene Saxon
- PATH, PO Box 900922, Seattle, WA 98109, USA
| | | | | | - Abhijeet Anand
- Centers for Disease Control and Prevention, 1600 Clifton Rd, Atlanta, GA 30333, USA
| | | |
Collapse
|
48
|
Van Mulder T, de Koeijer M, Theeten H, Willems D, Van Damme P, Demolder M, De Meyer G, Beyers K, Vankerckhoven V. High frequency ultrasound to assess skin thickness in healthy adults. Vaccine 2017; 35:1810-1815. [DOI: 10.1016/j.vaccine.2016.07.039] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 06/29/2016] [Accepted: 07/19/2016] [Indexed: 02/07/2023]
|
49
|
Robertson CA, Tsang P, Landolfi VA, Greenberg DP. Fluzone® Intradermal Quadrivalent Influenza Vaccine. Expert Rev Vaccines 2016; 15:1245-53. [PMID: 27457797 DOI: 10.1080/14760584.2016.1215246] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
INTRODUCTION An intradermal version of Fluzone® split-virion inactivated trivalent influenza vaccine, containing 9 µg hemagglutinin per strain of A/H1N1, A/H3N2, and one B lineage virus (Fluzone Intradermal, Sanofi Pasteur), became available in the US during the 2011-2012 influenza season for adults 18-64 years of age. In advance of the 2015-2016 season, Fluzone Intradermal was replaced with Fluzone Intradermal Quadrivalent vaccine, which contains 9 µg hemagglutinin per strain of the two A-strain viruses and both B-strain lineage viruses (Victoria and Yamagata). AREAS COVERED This literature review summarizes the history and mechanism of intradermal vaccination, discusses the clinical trial results supporting the immunogenicity and safety of Fluzone Intradermal Quadrivalent vaccine, and describes the unique microinjection system used to deliver Fluzone Intradermal Quadrivalent. Expert commentary: Fluzone Intradermal Quadrivalent may boost confidence in influenza vaccination with the addition of a second B-lineage strain. By using an innovative microinjection system, the vaccine is also designed to address some of the logistic challenges faced by healthcare providers administering immunizations.
Collapse
Affiliation(s)
- Corwin A Robertson
- a Scientific and Medical Affairs Department , Sanofi Pasteur Inc ., Discovery Drive, Swiftwater , PA , USA
| | - Peter Tsang
- b Clinical Development Department , Sanofi Pasteur Inc ., Swiftwater , PA , USA
| | - Victoria A Landolfi
- c Late Development and Innovation Department , Sanofi Pasteur Inc ., Swiftwater , PA , USA
| | - David P Greenberg
- a Scientific and Medical Affairs Department , Sanofi Pasteur Inc ., Discovery Drive, Swiftwater , PA , USA.,d Department of Pediatrics , University of Pittsburgh School of Medicine , Pittsburgh , PA , USA
| |
Collapse
|
50
|
Bragazzi NL, Orsi A, Ansaldi F, Gasparini R, Icardi G. Fluzone® intra-dermal (Intanza®/Istivac® Intra-dermal): An updated overview. Hum Vaccin Immunother 2016; 12:2616-2627. [PMID: 27246556 DOI: 10.1080/21645515.2016.1187343] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Influenza is a highly contagious respiratory acute viral disease which imposes a very heavy burden both in terms of epidemiology and costs, in the developed countries as well as in the developing ones. It represents a serious public health concern and vaccination constitutes an important tool to reduce or at least mitigate its burden. Despite the existence of a broad armamentarium against influenza and despite all the efforts and recommendations of international organisms to broaden immunization, influenza vaccination coverage is still far from being optimal. This, taken together with logistic and technical difficulties that can result into vaccine shortage, makes intra-dermal (ID) vaccines, such as Fluzone® ID and Intanza®, particularly attractive. ID vaccines are comparable and, in some cases, superior to intra-muscular/sub-cutaneous vaccines in terms of immunogenicity, safety, reactogenicity, tolerability and cross-protection profiles, as well as in terms of patient preference, acceptance and vaccine selection. Further advances, such as Fluzone® ID with alternative B strains and Quadrivalent Fluzone® ID or the possibility of self-administering the vaccines, make influenza ID vaccines even more valuable.
Collapse
Affiliation(s)
| | - Andrea Orsi
- a Department of Health Sciences (DISSAL) , University of Genoa , Genoa , Italy.,b Hygiene Unit, IRCCS AOU San Martino - IST of Genoa , Genoa , Italy
| | - Filippo Ansaldi
- a Department of Health Sciences (DISSAL) , University of Genoa , Genoa , Italy.,b Hygiene Unit, IRCCS AOU San Martino - IST of Genoa , Genoa , Italy
| | - Roberto Gasparini
- a Department of Health Sciences (DISSAL) , University of Genoa , Genoa , Italy
| | - Giancarlo Icardi
- a Department of Health Sciences (DISSAL) , University of Genoa , Genoa , Italy.,b Hygiene Unit, IRCCS AOU San Martino - IST of Genoa , Genoa , Italy
| |
Collapse
|