1
|
Maneein S, Sangsanont J, Limpiyakorn T, Sirikanchana K, Rattanakul S. The coagulation process for enveloped and non-enveloped virus removal in turbid water: Removal efficiencies, mechanisms and its application to SARS-CoV-2 Omicron BA.2. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 931:172945. [PMID: 38703849 DOI: 10.1016/j.scitotenv.2024.172945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 04/19/2024] [Accepted: 04/30/2024] [Indexed: 05/06/2024]
Abstract
The coagulation process has a high potential as a treatment method that can handle pathogenic viruses including emerging enveloped viruses in drinking water treatment process which can lower infection risk through drinking water consumption. In this study, a surrogate enveloped virus, bacteriophage Փ6, and surrogate non-enveloped viruses, including bacteriophage MS-2, T4, ՓX174, were used to evaluate removal efficiencies and mechanisms by the conventional coagulation process with alum, poly‑aluminum chloride, and ferric chloride at pH 5, 7, and 9 in turbid water. Also, treatability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a recent virus of global concern by coagulation was evaluated as SARS-CoV-2 can presence in drinking water sources. It was observed that an increase in the coagulant dose enhanced the removal efficiency of turbidity and viruses, and the condition that provided the highest removal efficiency of enveloped and non-enveloped viruses was 50 mg/L of coagulants at pH 5. In addition, the coagulation process was more effective for enveloped virus removal than for the non-enveloped viruses, and it demonstrated reduction of SARS-CoV-2 Omicron BA.2 over 0.83-log with alum. According to culture- and molecular-based assays (qPCR and CDDP-qPCR), the virus removal mechanisms were floc adsorption and coagulant inactivation. Through inactivation with coagulants, coagulants caused capsid destruction, followed by genome damage in non-enveloped viruses; however, damage to a lipid envelope is suggested to contribute to a great extend for enveloped virus inactivation. We demonstrated that conventional coagulation is a promising method for controlling emerging and re-emerging viruses in drinking water.
Collapse
Affiliation(s)
- Siriwara Maneein
- Department of Environmental Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand
| | - Jatuwat Sangsanont
- Department of Environmental Science, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand; Water Science and Technology for Sustainable Environmental Research Unit, Chulalongkorn University, Bangkok 10330, Thailand
| | - Tawan Limpiyakorn
- Department of Environmental Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
| | - Kwanrawee Sirikanchana
- Research Laboratory of Biotechnology, Chulabhorn Research Institute, Bangkok 10210, Thailand; Center of Excellence on Environmental Health and Toxicology (EHT), OPS, MHESI, Bangkok 10400, Thailand
| | - Surapong Rattanakul
- Department of Environmental Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand.
| |
Collapse
|
2
|
Yasui M, Katayama H. Unveiling the viral escape: Quantification of microfloc-bound viruses in precoagulation and membrane filtration. JOURNAL OF WATER AND HEALTH 2024; 22:309-320. [PMID: 38421625 PMCID: wh_2024_233 DOI: 10.2166/wh.2024.233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
The implementation of precoagulation before the physical removal process is expected to achieve a high virus removal rate. However, viruses may form small flocs and subsequently escape into the effluent during physical removal processes. This study evaluated how viruses in the microflocs could be quantified using conventional virus quantification methods (plaque assay and quantitative polymerase chain reaction (qPCR)) to reveal the risk of underestimating virus concentration. In this study, the microfloc dissolution phenomenon in phosphate buffer solution was employed as a floc dissolution test. Viruses in microflocs formed under the experimental conditions. assuming water treatments, were quantified before and after floc dissolution. The findings revealed that virus concentrations increased by 1.0-3.9 log plaque-forming units/mL according to the plaque assay and by 1.7-4.0 log copies/mL according to the qPCR. This increase occurred after the dissolution of microflocs that were prepared in the humic acid test water. In the case of treated wastewater, virus concentrations increased in all samples according to the plaque assay and in seven of eight samples according to the qPCR. Our results indicate the necessity of careful consideration of virus quantification after precoagulation and physical removal systems.
Collapse
Affiliation(s)
- Midori Yasui
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Department of Environmental Engineering, Kyoto University, Kyoto-Daigaku-Katsura, Nishikyo-ku, Kyoto 615-8540, Japan E-mail:
| | - Hiroyuki Katayama
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Research Center for Water Environment Technology, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| |
Collapse
|
3
|
Qin J, Ziemann E, Bar-Zeev E, Bone SE, Liang Y, Mauter MS, Herzberg M, Bernstein R. Microporous Polyethersulfone Membranes Grafted with Zwitterionic Polymer Brushes Showing Microfiltration Permeance and Ultrafiltration Bacteriophage Removal. ACS APPLIED MATERIALS & INTERFACES 2023; 15:18343-18353. [PMID: 37010122 DOI: 10.1021/acsami.3c01495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Virus removal from water using microfiltration (MF) membranes is of great interest but remains challenging owing to the membranes' mean pore sizes typically being significantly larger than most viruses. We present microporous membranes grafted with polyzwitterionic brushes (N-dimethylammonium betaine) that combine bacteriophage removal in the range of ultrafiltration (UF) membranes with the permeance of MF membranes. Brush structures were grafted in two steps: free-radical polymerization followed by atom transfer radical polymerization (ATRP). Attenuated total reflection Fourier transform infrared (ATR-FTIR) and X-ray photoelectron (XPS) verified that grafting occurred at both sides of the membranes and that the grafting increased with increasing the zwitterion monomer concentration. The log reduction values (LRVs) of the pristine membrane increased from less than 0.5 LRV for T4 (∼100 nm) and NT1 (∼50 nm) bacteriophages to up to 4.5 LRV for the T4 and 3.1 LRV for the NT1 for the brush-grafted membranes with a permeance of about 1000 LMH/bar. The high permeance was attributed to a high-water fraction in the ultra-hydrophilic brush structure. The high measured LRVs of the brush-grafted membranes were attributed to enhanced bacteriophages exclusion from the membrane surface and entrapment of the ones that penetrated the pores due to the membranes' smaller mean pore-size and cross-section porosity than those of the pristine membrane, as seen by scanning electron microscopy (SEM) and measured using liquid-liquid porometry. Micro X-ray fluorescence (μ-XRF) spectrometry and nanoscale secondary ion mass spectrometry showed that 100 nm Si-coated gold nanospheres accumulated on the surface of the pristine membrane but not on the brush-coated membrane and that the nanospheres that penetrated the membranes were entrapped in the brush-grafted membrane but passed the pristine one. These results corroborate the LRVs obtained during filtration experiments and support the inference that the increased removal was due to a combined exclusion mechanism and entrapment. Overall, these microporous brush-grafted membranes show potential for use in advanced water treatment.
Collapse
Affiliation(s)
- Ji Qin
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev, Campus Sde Boker, Midreshet 84990, Israel
| | - Eric Ziemann
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev, Campus Sde Boker, Midreshet 84990, Israel
| | - Edo Bar-Zeev
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev, Campus Sde Boker, Midreshet 84990, Israel
| | - Sharon E Bone
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, California 94025, United States
| | - Yuanzhe Liang
- Civil and Environmental Engineering, Stanford University, Stanford, California 94305, United States
| | - Meagan S Mauter
- Civil and Environmental Engineering, Stanford University, Stanford, California 94305, United States
| | - Moshe Herzberg
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev, Campus Sde Boker, Midreshet 84990, Israel
| | - Roy Bernstein
- Zuckerberg Institute for Water Research, The Jacob Blaustein Institutes for Desert Research of the Ben-Gurion University of the Negev, Campus Sde Boker, Midreshet 84990, Israel
| |
Collapse
|
4
|
Adachi Katayama Y, Hayase S, Ando Y, Kuroita T, Okada K, Iwamoto R, Yanagimoto T, Kitajima M, Masago Y. COPMAN: A novel high-throughput and highly sensitive method to detect viral nucleic acids including SARS-CoV-2 RNA in wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 856:158966. [PMID: 36162583 PMCID: PMC9502438 DOI: 10.1016/j.scitotenv.2022.158966] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 09/16/2022] [Accepted: 09/19/2022] [Indexed: 05/15/2023]
Abstract
During the coronavirus disease 2019 (COVID-19) pandemic, wastewater-based epidemiology (WBE) attracted attention as an objective and comprehensive indicator of community infection that does not require individual inspection. Although several severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection methods from wastewater have been developed, there are obstacles to their social implementation. In this study, we developed the COPMAN (Coagulation and Proteolysis method using Magnetic beads for detection of Nucleic acids in wastewater), an automatable method that can concentrate and detect multiple types of viruses from a limited volume (∼10 mL) of wastewater. The COPMAN consists of a high basicity polyaluminum chloride (PAC) coagulation process, magnetic bead-based RNA purification, and RT-preamplification, followed by qPCR. A series of enzymes exhibiting a high tolerance to PCR inhibitors derived from wastewater was identified and employed in the molecular detection steps in the COPMAN. We compared the detectability of viral RNA from 10-mL samples of virus-spiked (heat-inactivated SARS-CoV-2 and intact RSV) or unspiked wastewater by the COPMAN and other methods (PEG-qPCR, UF-qPCR, and EPISENS-S). The COPMAN was the most efficient for detecting spiked viruses from wastewater, detecting the highest level of pepper mild mottle virus (PMMoV), a typical intrinsic virus in human stool, from wastewater samples. The COPMAN also successfully detected indigenous SARS-CoV-2 RNA from 12 samples of wastewater at concentrations of 2.2 × 104 to 5.4 × 105 copies/L, during initial stages of an infection wave in the right and the left bank of the Sagami River in Japan (0.65 to 11.45 daily reported cases per 100,000 people). These results indicate that the COPMAN is suitable for detection of multiple pathogens from small volume of wastewater in automated stations.
Collapse
Affiliation(s)
- Yuka Adachi Katayama
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan
| | - Shin Hayase
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan
| | - Yoshinori Ando
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan
| | - Tomohiro Kuroita
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan; AdvanSentinel Inc., 3-1-8 Doshomachi, Chuo-ku, Osaka 541-0045, Japan
| | - Kazuya Okada
- Shionogi & Co., Ltd., Head Office, 3-1-8 Doshomachi, Chuo-ku, Osaka 541-0045, Japan
| | - Ryo Iwamoto
- Shionogi & Co., Ltd., Head Office, 3-1-8 Doshomachi, Chuo-ku, Osaka 541-0045, Japan; AdvanSentinel Inc., 3-1-8 Doshomachi, Chuo-ku, Osaka 541-0045, Japan
| | - Toru Yanagimoto
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan
| | - Masaaki Kitajima
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, North 13 West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Yusaku Masago
- Shionogi & Co., Ltd., Pharmaceutical Research Center, 1-1, Futaba-cho 3-chome, Toyonaka, Osaka 561-0825, Japan.
| |
Collapse
|
5
|
Chen L, Deng Y, Dong S, Wang H, Li P, Zhang H, Chu W. The occurrence and control of waterborne viruses in drinking water treatment: A review. CHEMOSPHERE 2021; 281:130728. [PMID: 34010719 PMCID: PMC8084847 DOI: 10.1016/j.chemosphere.2021.130728] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/21/2021] [Accepted: 04/25/2021] [Indexed: 05/04/2023]
Abstract
As the coronavirus disease 2019 continues to spread globally, its culprit, the severe acute respiratory syndrome coronavirus 2 has been brought under scrutiny. In addition to inhalation transmission, the possible fecal-oral viral transmission via water/wastewater has also been brought under the spotlight, necessitating a timely global review on the current knowledge about waterborne viruses in drinking water treatment system - the very barrier that intercepts waterborne pathogens to terminal water users. In this article we reviewed the occurrence, concentration methods, and control strategies, also, treatment performance on waterborne viruses during drinking water treatment were summarized. Additionally, we emphasized the potential of applying the quantitative microbial risk assessment to guide drinking water treatment to mitigate the viral exposure risks, especially when the unregulated novel viral pathogens are of concern. This review paves road for better control of viruses at drinking water treatment plants to protect public health.
Collapse
Affiliation(s)
- Li Chen
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Yang Deng
- Department of Earth and Environmental Studies, Montclair State University, Montclair, NJ, USA
| | - Shengkun Dong
- Key LLaboratory of Water Cycle and Water Security in Southern China of Guangdong Higher Education Institute, School of Civil Engineering, Sun Yat-sen University, Guangdong, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Pan Li
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Huaiyu Zhang
- Central and Southern China Institute of Municipal Engineering Design and Research, Hubei, China
| | - Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China.
| |
Collapse
|
6
|
Mohan SV, Hemalatha M, Kopperi H, Ranjith I, Kumar AK. SARS-CoV-2 in environmental perspective: Occurrence, persistence, surveillance, inactivation and challenges. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2021; 405:126893. [PMID: 32901196 PMCID: PMC7471803 DOI: 10.1016/j.cej.2020.126893] [Citation(s) in RCA: 76] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/29/2020] [Accepted: 08/31/2020] [Indexed: 05/03/2023]
Abstract
The unprecedented global spread of the severe acute respiratory syndrome (SARS) caused by SARS-CoV-2 is depicting the distressing pandemic consequence on human health, economy as well as ecosystem services. So far novel coronavirus (CoV) outbreaks were associated with SARS-CoV-2 (2019), middle east respiratory syndrome coronavirus (MERS-CoV, 2012), and SARS-CoV-1 (2003) events. CoV relates to the enveloped family of Betacoronavirus (βCoV) with positive-sense single-stranded RNA (+ssRNA). Knowing well the persistence, transmission, and spread of SARS-CoV-2 through proximity, the faecal-oral route is now emerging as a major environmental concern to community transmission. The replication and persistence of CoV in the gastrointestinal (GI) tract and shedding through stools is indicating a potential transmission route to the environment settings. Despite of the evidence, based on fewer reports on SARS-CoV-2 occurrence and persistence in wastewater/sewage/water, the transmission of the infective virus to the community is yet to be established. In this realm, this communication attempted to review the possible influx route of the enteric enveloped viral transmission in the environmental settings with reference to its occurrence, persistence, detection, and inactivation based on the published literature so far. The possibilities of airborne transmission through enteric virus-laden aerosols, environmental factors that may influence the viral transmission, and disinfection methods (conventional and emerging) as well as the inactivation mechanism with reference to the enveloped virus were reviewed. The need for wastewater epidemiology (WBE) studies for surveillance as well as for early warning signal was elaborated. This communication will provide a basis to understand the SARS-CoV-2 as well as other viruses in the context of the environmental engineering perspective to design effective strategies to counter the enteric virus transmission and also serves as a working paper for researchers, policy makers and regulators.
Collapse
Key Words
- (h+), Photoholes
- +ssRNA, Positive Sense Single-Stranded RNA
- A-WWTS, Algal-WWTS
- ACE2, Angiotensin-converting enzyme 2
- AH, Absolute Humidity
- AOPs, Advanced Oxidation Processes
- ASP, Activate Sludge Process
- Aerosols
- BCoV, Bovine Enteric Coronavirus)
- BSL, Biosafety Level
- BVDV1, Bovine Viral Diarrhea Virus Type 1
- BVDV2, Bovine Viral Diarrhea Virus Type 2
- BoRv, Bovine Rotavirus Group A
- CCA, Carbon Covered Alumina
- CNT, Carbon Nanotubes
- COVID-19
- COVID-19, Coronavirus Disease 2019
- CRFK, Crandell Reese feline kidney cell line (CRFK)
- CVE, Coxsackievirus B5
- ClO2, Chlorine dioxide
- Cl−, Chlorine
- Cys, Cysteine
- DBP, Disinfection by-products
- DBT, L2 and Delayed Brain Tumor Cell Cultures
- DMEM, Dulbecco’s Modified Eagle Medium
- DNA, deoxyribose nucleic acid
- Disinfection
- E gene, Envelope protein gene
- EV, Echovirus 11
- Enteric virus
- Enveloped virus
- FC, Free Chlorine
- FFP3, Filtering Face Piece
- FIPV, Feline infectious peritonitis virus
- GI, Gastrointestinal tract
- H2O2, Hydrogen Peroxide
- H3N2, InfluenzaA
- H6N2, Avian influenza virus
- HAV, Hepatitis A virus (HAV)
- HAdV, Human Adenovirus
- HCoV, Human CoV
- HEV, Hepatitis E virus
- HKU1, Human CoV1
- ICC-PCR, Integrated Cell Culture with PCR
- JCV, JCV polyomavirus
- MALDI-TOF MS, Mass Spectrometry
- MBR, Membrane Bioreactor (MBR)
- MERS-CoV, Middle East Respiratory Syndrome Coronavirus
- MHV, Murine hepatitis virus
- MNV-1, Murine Norovirus
- MWCNTs, Multiwalled Carbon Nanotubes
- Met, Methionine
- N gene, Nucleocapsid protein gene
- NCoV, Novel coronavirus
- NGS, Next generation sequencing
- NTP, Non-Thermal Plasma
- O2, Singlet Oxygen
- O3, Ozone
- ORF, Open Reading Frame
- PAA, Para Acetic Acid
- PCR, Polymerase Chain Reaction
- PEC, Photoelectrocatalytical
- PEG, Polyethylene Glycol
- PFU, Plaque Forming Unit
- PMMoV, Pepper Mild Mottle Virus
- PMR, Photocatalytic Membrane Reactors
- PPE, Personal Protective Equipment
- PTAF, Photocatalytic Titanium Apatite Filter
- PV-1, Polivirus-1
- PV-3, Poliovirus 3
- PVDF, Polyvinylidene Fluoride
- Qβ, bacteriophages
- RH, Relative Humidity
- RNA, Ribose nucleic acid
- RONS, Reactive Oxygen and/or Nitrogen Species
- RT-PCR, Real Time Polymerase Chain Reaction
- RVA, Rotaviruses A
- SARS-CoV-1, Severe Acute Respiratory Syndrome Coronavirus 1
- SARS-CoV-2, Severe Acute Respiratory Syndrome Coronavirus 2
- SBR, Sequential Batch Reactor
- SODIS, Solar water disinfection
- STP, Sewage Treatment Plant
- Sewage
- T90, First order reaction time required for completion of 90%
- T99.9, First order reaction time required for completion of 99.9%
- TGEV, Porcine Coronavirus Transmissible Gastroenteritis Virus
- TGEV, Transmissible Gastroenteritis
- Trp, Tryptophan
- Tyr, Tyrosine
- US-EPA, United States Environmental Protection Agency
- UV, Ultraviolet
- WBE, Wastewater-Based Epidemiology
- WWT, Wastewater Treatment
- WWTPs, Wastewater Treatment Plants
- dPCR, Digital PCR
- ds, Double Stranded
- dsDNA, Double Stranded DNA
- log10, logarithm with base 10
- qRT-PCR, quantitative RT-PCR
- ss, Single Stranded
- ssDNA, Single Stranded DNA
- ssRNA, Single Stranded RNA
- αCoV, Alphacoronavirus
- βCoV, Betacoronavirus
Collapse
Affiliation(s)
- S Venkata Mohan
- Bioengineering and Environmental Sciences Lab, Department of Energy and Environmental Engineering (DEEE), CSIR-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad 500007, India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Indian Institute of Chemical Technology (CSIR-IICT) Campus, Hyderabad 500007, India
| | - Manupati Hemalatha
- Bioengineering and Environmental Sciences Lab, Department of Energy and Environmental Engineering (DEEE), CSIR-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad 500007, India
- Academy of Scientific and Innovative Research (AcSIR), CSIR-Indian Institute of Chemical Technology (CSIR-IICT) Campus, Hyderabad 500007, India
| | - Harishankar Kopperi
- Bioengineering and Environmental Sciences Lab, Department of Energy and Environmental Engineering (DEEE), CSIR-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad 500007, India
| | - I Ranjith
- Bioengineering and Environmental Sciences Lab, Department of Energy and Environmental Engineering (DEEE), CSIR-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad 500007, India
| | - A Kiran Kumar
- Bioengineering and Environmental Sciences Lab, Department of Energy and Environmental Engineering (DEEE), CSIR-Indian Institute of Chemical Technology (CSIR-IICT), Hyderabad 500007, India
- CSIR-Indian Institute of Chemical Technology (CSIR-IICT) Dispensary, Hyderabad 500007, India
| |
Collapse
|
7
|
Mohammed H, Seidu R. Climate-driven QMRA model for selected water supply systems in Norway accounting for raw water sources and treatment processes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 660:306-320. [PMID: 30640099 DOI: 10.1016/j.scitotenv.2018.12.460] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 12/28/2018] [Accepted: 12/30/2018] [Indexed: 06/09/2023]
Abstract
Formulating effective management intervention measures for water supply systems requires investigation of potential long-term impacts. This study applies an integrated multiple regression, random forest regression, and quantitative microbial risk assessment (QMRA) modelling approach to assess the effect of climate-driven precipitation on pathogen infection risks in three drinking water treatment plants (WTPs) in Norway. Pathogen removal efficacies of treatment steps were calculated using process models. The results indicate that while the WTPs investigated generally meet the current water safety guidelines, risks of Norovirus and Cryptosporidium infection may be of concern in the future. The pathogen infections attributable to current projections of average precipitation in the study locations may be low. However, the pathogen increases in the drinking water sources due to the occurrence of extreme precipitation events in the catchments could substantially increase the risks of pathogen infections. In addition, without optimal operation of the UV disinfection steps in the WTPs, both the present and potential future infection risks could be high. Therefore, the QMRA models demonstrated the need for improved optimization of key treatment steps in the WTPs, as well as implementation of stringent regulations in protecting raw water sources in the country. The variety of models applied and the pathogen: E. coli used in the study introduce some uncertainties in the results, thus, management decisions that will be based on the results should consider these limitations. Nevertheless, the integration of predictive models with QMRA as applied in this study could be a useful method for climate impact assessment in the water supply industry.
Collapse
Affiliation(s)
- Hadi Mohammed
- Water and Environmental Engineering Group, Department of Civil Engineering, Institute for Marine Operations and Civil Engineering, Norwegian University of Science and Technology (NTNU) in Ålesund, Larsgårdsvegen 2, 6009 Ålesund, Norway.
| | - Razak Seidu
- Water and Environmental Engineering Group, Department of Civil Engineering, Institute for Marine Operations and Civil Engineering, Norwegian University of Science and Technology (NTNU) in Ålesund, Larsgårdsvegen 2, 6009 Ålesund, Norway
| |
Collapse
|
8
|
Kato R, Asami T, Utagawa E, Furumai H, Katayama H. Pepper mild mottle virus as a process indicator at drinking water treatment plants employing coagulation-sedimentation, rapid sand filtration, ozonation, and biological activated carbon treatments in Japan. WATER RESEARCH 2018; 132:61-70. [PMID: 29306700 DOI: 10.1016/j.watres.2017.12.068] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 12/13/2017] [Accepted: 12/23/2017] [Indexed: 05/12/2023]
Abstract
To assess the potential of pepper mild mottle virus (PMMoV) as a viral process indicator, its reduction through coagulation-sedimentation (CS) and rapid sand filtration (RSF) were compared with those of Escherichia coli, previously used viral indicators, and norovirus genotype II (NoV GII; enteric virus reference pathogen) in a bench-scale experiment. PMMoV log10 reductions in CS (1.96 ± 0.30) and RSF (0.26 ± 0.38) were similar to those of NoV GII (1.86 ± 0.61 and 0.28 ± 0.46). PMMoV, the most abundant viruses in the raw water, was also determined during CS, RSF, and advanced treatment processes at two full-scale drinking water treatment plants under strict turbidity management over a 13-month period. PMMoV was concentrated from large-volume water samples (10-614 L) and quantified by Taqman-based quantitative polymerase chain reaction. The PMMoV log10 reduction in CS (2.38 ± 0.74, n = 13 and 2.63 ± 0.76, n = 10 each for Plant A and B) and in ozonation (1.91 ± 1.18, n = 5, Plant A) greatly contributed to the overall log10 reduction. Our results suggest that PMMoV can act as a useful treatment process indicator of enteric viruses and can be used to monitor the log10 reduction of individual treatment processes at drinking water treatment plants due to its high and consistent copy numbers in source water.
Collapse
Affiliation(s)
- Ryuichi Kato
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Tatsuya Asami
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Etsuko Utagawa
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Vietnam - Japan University, Luu Huu Phuoc Str., My Dinh I Ward, Nam Tu Liem Dist., Hanoi, Viet Nam.
| |
Collapse
|
9
|
Chaudhry RM, Hamilton KA, Haas CN, Nelson KL. Drivers of Microbial Risk for Direct Potable Reuse and de Facto Reuse Treatment Schemes: The Impacts of Source Water Quality and Blending. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2017; 14:E635. [PMID: 28608808 PMCID: PMC5486321 DOI: 10.3390/ijerph14060635] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 06/06/2017] [Accepted: 06/07/2017] [Indexed: 11/16/2022]
Abstract
Although reclaimed water for potable applications has many potential benefits, it poses concerns for chemical and microbial risks to consumers. We present a quantitative microbial risk assessment (QMRA) Monte Carlo framework to compare a de facto water reuse scenario (treated wastewater-impacted surface water) with four hypothetical Direct Potable Reuse (DPR) scenarios for Norovirus, Cryptosporidium, and Salmonella. Consumer microbial risks of surface source water quality (impacted by 0-100% treated wastewater effluent) were assessed. Additionally, we assessed risks for different blending ratios (0-100% surface water blended into advanced-treated DPR water) when source surface water consisted of 50% wastewater effluent. De facto reuse risks exceeded the yearly 10-4 infections risk benchmark while all modeled DPR risks were significantly lower. Contamination with 1% or more wastewater effluent in the source water, and blending 1% or more wastewater-impacted surface water into the advanced-treated DPR water drove the risk closer to the 10-4 benchmark. We demonstrate that de facto reuse by itself, or as an input into DPR, drives microbial risks more so than the advanced-treated DPR water. When applied using location-specific inputs, this framework can contribute to project design and public awareness campaigns to build legitimacy for DPR.
Collapse
Affiliation(s)
- Rabia M Chaudhry
- Civil and Environmental Engineering, University of California, Berkeley, CA 94720, USA.
- Engineering Research Center for Re-Inventing the Nation's Urban Water Infrastructure (ReNUWIt), Berkeley, CA 94720-1710, USA.
| | - Kerry A Hamilton
- Drexel University Department of Civil, Architectural, and Environmental Engineering, 3141 Chestnut Street, Philadelphia, PA 19104, USA.
| | - Charles N Haas
- Drexel University Department of Civil, Architectural, and Environmental Engineering, 3141 Chestnut Street, Philadelphia, PA 19104, USA.
| | - Kara L Nelson
- Civil and Environmental Engineering, University of California, Berkeley, CA 94720, USA.
- Engineering Research Center for Re-Inventing the Nation's Urban Water Infrastructure (ReNUWIt), Berkeley, CA 94720-1710, USA.
| |
Collapse
|
10
|
Shirasaki N, Matsushita T, Matsui Y, Murai K, Aochi A. Elimination of representative contaminant candidate list viruses, coxsackievirus, echovirus, hepatitis A virus, and norovirus, from water by coagulation processes. JOURNAL OF HAZARDOUS MATERIALS 2017; 326:110-119. [PMID: 28011355 DOI: 10.1016/j.jhazmat.2016.11.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2016] [Revised: 10/14/2016] [Accepted: 11/02/2016] [Indexed: 05/24/2023]
Abstract
We examined the removal of representative contaminant candidate list (CCL) viruses (coxsackievirus [CV] B5, echovirus type [EV] 11, and hepatitis A virus [HAV] IB), recombinant norovirus virus-like particles (rNV-VLPs), and murine norovirus (MNV) type 1 by coagulation. Water samples were subjected to coagulation with polyaluminum chloride (PACl, basicity 1.5) followed by either settling or settling and filtration. Together with our previously published results, the removal ratio order, as evaluated by a plaque-forming-unit method or an enzyme-linked immunosorbent assay after settling, was HAV>EV=rNV-VLPs≥CV=poliovirus type 1=MNV>adenovirus type 40 (range, 0.1-2.7-log10). Infectious HAV was likely inactivated by the PACl and therefore was removed to a greater extent than the other viruses. A nonsulfated high-basicity PACl (basicity 2.1), removed the CCL viruses more efficiently than did two other sulfated PACls (basicity 1.5 or 2.1), alum, or ferric chloride. We also examined the removal ratio of two bacteriophages. The removal ratios for MS2 tended to be larger than those of the CCL viruses, whereas those for φX174 were comparable with or smaller than those of the CCL viruses. Therefore, φX174 may be a useful conservative surrogate for CCL viruses during coagulation.
Collapse
Affiliation(s)
- N Shirasaki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan.
| | - T Matsushita
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan
| | - Y Matsui
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan
| | - K Murai
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan
| | - A Aochi
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan
| |
Collapse
|
11
|
Yasui N, Suwa M, Sakurai K, Suzuki Y, Tsumori J, Kobayashi K, Takabatake H, Lee ST, Yamashita N, Tanaka H. Removal characteristics and fluctuation of norovirus in a pilot-plant by an ultrafiltration membrane for the reclamation of treated sewage. ENVIRONMENTAL TECHNOLOGY 2016; 37:2793-801. [PMID: 26979931 DOI: 10.1080/09593330.2016.1164760] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
When ultrafiltration (UF) membrane processes that are able to effectively reduce viruses are installed in a waste water reclamation system, the security of sanitation safety for water-borne diseases is essential. It is important to understand the behaviour of enteric viruses such as Adenovirus, Rotavirus and Norovirus (NV), the detection rate of which is relatively high in sewage. This study focused on the UF membrane process for the reclaimed water treatment process, and investigated the removal performance in NV type GI and GII in the UF membrane process by performing coagulation and sedimentation as the pre-treatment process in a pilot-plant by considering the concentration fluctuation of the influent. The removal ratio of GI and GII by the UF membrane process alone was 3.3 ± 0.7 Log in GI and 3.6 ± 1.0 Log in GII, and no clear difference in the removal ratio by NV species type was observed. The removal ratio of NV GII was increased by about 0.6 Log on average (4.2 ± 1.1 Log) compared with the UF membrane process only when the coagulation and sedimentation process were conducted as pre-treatment. However, there was no significant difference in the removal of NV GI by conducting the coagulation and sedimentation process.
Collapse
Affiliation(s)
- Nobuhito Yasui
- a National Research and Development Agency Public Works Research Institute , Tokyo , Japan
- b CREST (Core Research for Evolutional Science and Technology) , Japan Science and Technology Agency , Tokyo , Japan
| | - Mamoru Suwa
- a National Research and Development Agency Public Works Research Institute , Tokyo , Japan
| | - Kensuke Sakurai
- a National Research and Development Agency Public Works Research Institute , Tokyo , Japan
| | - Yutaka Suzuki
- a National Research and Development Agency Public Works Research Institute , Tokyo , Japan
- c National Institute for Land and Infrastructure Management , Tsukuba , Japan
| | - Jun Tsumori
- a National Research and Development Agency Public Works Research Institute , Tokyo , Japan
- d Hamamatsu City Waterworks Bureau , Shizuoka , Japan
| | - Kentaro Kobayashi
- e Global Environment Research Laboratories , Toray Industries, Inc ., Tokyo , Japan
| | - Hiroo Takabatake
- e Global Environment Research Laboratories , Toray Industries, Inc ., Tokyo , Japan
| | - Sun Tae Lee
- f Graduate School of Engineering , Kyoto University , Kyoto , Japan
| | | | - Hiroaki Tanaka
- f Graduate School of Engineering , Kyoto University , Kyoto , Japan
| |
Collapse
|
12
|
Zhang CM, Xu LM, Xu PC, Wang XC. Elimination of viruses from domestic wastewater: requirements and technologies. World J Microbiol Biotechnol 2016; 32:69. [PMID: 26931609 DOI: 10.1007/s11274-016-2018-3] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Accepted: 01/22/2016] [Indexed: 02/02/2023]
Abstract
Domestic wastewater contains various pathogens, which, if not sufficiently eliminated, may enter the receiving water bodies and cause water-transmitted diseases. Among the waterborne pathogens, viruses may occur, survive and/or decay much differently from bacteria in water. In many cases, the diseases caused by viruses are more severe. Therefore, research efforts are mainly directed at the behavior of viruses in water environments, as well as the elimination of viruses from wastewater. In this paper, an overview of the occurrence of viruses in wastewater is presented, together with their categories, methods of detection and potential to cause waterborne diseases. As wastewater treatment plants are critical nodes for the influx and termination of virus transmission, the behavior of viruses at each stage of treatment is reviewed. Particular attention is paid to the unit operations, which play crucial roles in virus removals, such as coagulation and membrane filtration, and that for virus inactivation, such as chemical disinfection and UV irradiation. Future needs for the development of new technologies for virus elimination, source control, and finding more suitable indicators of viral pathogens are also highlighted.
Collapse
Affiliation(s)
- Chong-Miao Zhang
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
| | - Li-Mei Xu
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China
| | - Peng-Cheng Xu
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China
| | - Xiaochang C Wang
- Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China.
| |
Collapse
|
13
|
Skibinski B, Müller P, Uhl W. Rejection of submicron sized particles from swimming pool water by a monolithic SiC microfiltration membrane: Relevance of steric and electrostatic interactions. J Memb Sci 2016. [DOI: 10.1016/j.memsci.2015.10.033] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Ryu S, You HJ, Kim YW, Lee A, Ko GP, Lee SJ, Song MJ. Inactivation of norovirus and surrogates by natural phytochemicals and bioactive substances. Mol Nutr Food Res 2014; 59:65-74. [PMID: 25410634 DOI: 10.1002/mnfr.201400549] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Revised: 11/13/2014] [Accepted: 11/13/2014] [Indexed: 01/11/2023]
Abstract
Human norovirus is the leading cause of sporadic gastroenteritis, which is responsible for more than 90% of all nonbacterial gastroenteritis outbreaks. While norovirus infections typically cause mild and self-limiting symptoms lasting 24-48 h, chronic persistent infections can cause severe symptoms. Although recent advances have been made in understanding the molecular characteristics of norovirus infection, no norovirus-specific antiviral drugs, or vaccines are available. Conventional intervention methods used to inactivate norovirus, such as treatment with disinfecting agents (e.g. ethanol, hypochlorite, and quaternary ammonium formulations), have shown a lack of efficacy against human norovirus when they are applied to foods and in food preparation processes. Therefore, alternative antiviral or inactivating agents such as phytochemicals have received attention as potential norovirus inhibitors due to their relatively low toxicity and lack of side effects, which allows them to be prepared as food-safe formulations. Evidence from studies using viral surrogates suggests that numerous phytochemicals and foods containing flavonoids and polyphenols have anti-norovirus activity, and future studies will be necessary to confirm the effectiveness of such compounds against human norovirus and the molecular mechanisms through which they produce antiviral effects.
Collapse
Affiliation(s)
- Seungbo Ryu
- Department of Biosystems and Biotechnology, Division of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul, Republic of Korea
| | | | | | | | | | | | | |
Collapse
|
15
|
Rygaard M, Godskesen B, Jørgensen C, Hoffmann B. Holistic assessment of a secondary water supply for a new development in Copenhagen, Denmark. THE SCIENCE OF THE TOTAL ENVIRONMENT 2014; 497-498:430-439. [PMID: 25150737 DOI: 10.1016/j.scitotenv.2014.07.078] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 07/12/2014] [Accepted: 07/20/2014] [Indexed: 06/03/2023]
Abstract
Increasing stress on water resources is driving urban water utilities to establish new concepts for water supply. This paper presents the consequences of proposed alternative water supply options using a unique combination of quantitative and qualitative methods from different research fields. A former industrial harbor area in Copenhagen, Denmark, is currently under development and all infrastructure will be updated to accommodate 40,000 inhabitants and 40,000 jobs in the future. To reduce stress on water resources it has been proposed to establish a secondary water supply in the area as an alternative to the conventional groundwater-based drinking water supply. Four alternative concepts for a secondary water supply have been considered: 1) slightly polluted groundwater for use in toilets and laundry, 2) desalinated brackish water for use in toilets, laundry, and dishwashers, 3) desalinated brackish water for all uses, including drinking water, and 4) local reclamation of rain and gray water for use in toilets and laundry. The concepts have been evaluated for their technical feasibility, economy, health risks, and public acceptance, while the concepts' environmental sustainability has been assessed using lifecycle assessment and freshwater use impact methods. The holistic assessment method exposes conflicting preference solutions depending on assessment criteria, and reveals multi-faceted consequences for choices in urban water management. Not one concept turns out unambiguously positive based on the evaluation criteria included here, but the systematic evaluation will leave decision-makers informed on the consequences of their choices.
Collapse
Affiliation(s)
- M Rygaard
- Technical University of Denmark, Department of Environmental Engineering, Miljoevej 113, DK-2800 Kgs. Lyngby, Denmark.
| | - B Godskesen
- HOFOR, Ørestads Boulevard 35, DK-2300 København S, Denmark.
| | | | - B Hoffmann
- Aalborg University, Department of Development and Planning, A.C. Meyers Vænge 15, 2450 København SV, Denmark.
| |
Collapse
|
16
|
Dika C, Duval JFL, Francius G, Perrin A, Gantzer C. Isoelectric point is an inadequate descriptor of MS2, Phi X 174 and PRD1 phages adhesion on abiotic surfaces. J Colloid Interface Sci 2014; 446:327-34. [PMID: 25265875 DOI: 10.1016/j.jcis.2014.08.055] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Revised: 08/24/2014] [Accepted: 08/26/2014] [Indexed: 10/24/2022]
Abstract
MS2, Phi X 174 and PRD1 bacteriophages are commonly used as surrogates to evaluate pathogenic virus behavior in natural aquatic media. The interfacial properties of these model soft bioparticles are herein discussed in connection with their propensities to adhere onto abiotic surfaces that differ in terms of surface charges and hydrophobicities. The phages considered in this work exhibit distinct multilayered surface structures and their electrostatic charges are evaluated from the dependence of their electrophoretic mobilities on electrolyte concentration at neutral pH on the basis of electrokinetic theory for soft (bio)particles. The charges of the viruses probed by electrokinetics vary according to the sequence Phi X 174⩽PRD1≪MS2, where '<' stands for 'less charged than'. The hydrophobic/hydrophilic balances of the phages are further derived from their adhesions onto model hydrophobic and hydrophilic self-assembled mono-layers. The corresponding results lead to the following hydrophobicity sequence Phi X 174≪MS2<PRD1 where '<' means 'less hydrophobic than'. The respective electrostatic and hydrophobic/hydrophilic features of the phages are further shown to be consistent with their measured adhesions onto polyethersulfone-based membranes with distinct hydrophobicities and charge levels. The methodology clearly demonstrates that the traditionally adopted phage isoelectric point as a relevant physicochemical descriptor for phage adhesion is not adequate for MS2, Phi X 174 and PRD1 bacteriophages.
Collapse
Affiliation(s)
- Christelle Dika
- Université de Lorraine, LCPME (Laboratoire de Chimie Physique et Microbiologie pour l'Environnement), UMR 7564, Nancy F-54000, France; CNRS, LCPME, UMR 7564, Nancy F-54000, France
| | - Jérôme F L Duval
- Université de Lorraine, LIEC (Laboratoire Interdisciplinaire des Environnements Continentaux), UMR 7360, Vandoeuvre-lès-Nancy F-54501, France; CNRS, LIEC, UMR 7360, Vandoeuvre-lès-Nancy F-54501, France.
| | - Gregory Francius
- Université de Lorraine, LCPME (Laboratoire de Chimie Physique et Microbiologie pour l'Environnement), UMR 7564, Nancy F-54000, France; CNRS, LCPME, UMR 7564, Nancy F-54000, France
| | - Aline Perrin
- Université de Lorraine, LCPME (Laboratoire de Chimie Physique et Microbiologie pour l'Environnement), UMR 7564, Nancy F-54000, France; CNRS, LCPME, UMR 7564, Nancy F-54000, France
| | - Christophe Gantzer
- Université de Lorraine, LCPME (Laboratoire de Chimie Physique et Microbiologie pour l'Environnement), UMR 7564, Nancy F-54000, France; CNRS, LCPME, UMR 7564, Nancy F-54000, France.
| |
Collapse
|
17
|
Mehta PK, Raj A, Singh NP, Khuller GK. Detection of potential microbial antigens by immuno-PCR (PCR-amplified immunoassay). J Med Microbiol 2014; 63:627-641. [PMID: 24568881 DOI: 10.1099/jmm.0.070318-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Immuno-PCR (PCR-amplified immunoassay; I-PCR) is a novel ultrasensitive method combining the versatility of ELISA with the sensitivity of nucleic acid amplification of PCR. The enormous exponential amplification power of PCR in an I-PCR assay leads to at least a 10(2)-10(4)-fold increase in sensitivity compared with an analogous ELISA. I-PCR has been used to detect many biological molecules such as proto-oncogenes, toxins, cytokines, hormones, and biomarkers for autoimmune and Alzheimer's diseases, as well as microbial antigens and antibodies, and it can be adapted as a novel diagnostic tool for various infectious and non-infectious diseases. Quantitative real-time I-PCR has the potential to become the most analytically sensitive method for the detection of proteins. The sensitivity and specificity of a real-time I-PCR assay can be enhanced further with the use of magnetic beads and nanoparticles. This review is primarily focused on the detection of potential viral, bacterial and parasitic antigens by I-PCR assay, thus enabling their application for immunological research and for early diagnosis of infectious diseases.
Collapse
Affiliation(s)
- Promod K Mehta
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak-124001 (Haryana), India
| | - Ankush Raj
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak-124001 (Haryana), India
| | - Netra Pal Singh
- Centre for Biotechnology, Maharshi Dayanand University, Rohtak-124001 (Haryana), India
| | - Gopal K Khuller
- Department of Biochemistry, Postgraduate Institute of Medical Education and Research, Chandigarh-160014, India
| |
Collapse
|
18
|
Shirasaki N, Matsushita T, Matsui Y, Oshiba A, Marubayashi T, Sato S. Improved virus removal by high-basicity polyaluminum coagulants compared to commercially available aluminum-based coagulants. WATER RESEARCH 2014; 48:375-386. [PMID: 24139360 DOI: 10.1016/j.watres.2013.09.052] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Revised: 09/22/2013] [Accepted: 09/27/2013] [Indexed: 05/27/2023]
Abstract
We investigated the effects of basicity, sulfate content, and aluminum hydrolyte species on the ability of polyaluminum chloride (PACl) coagulants to remove F-specific RNA bacteriophages from river water at a pH range of 6-8. An increase in PACl basicity from 1.5 to 2.1 and the absence of sulfate led to a reduction of the amount of monomeric aluminum species (i.e., an increase of the total amount of polymeric aluminum and colloidal aluminum species) in the PACl, to an increase in the colloid charge density of the PACl, or to both and, as a result, to high virus removal efficiency. The efficiency of virus removal at around pH 8 observed with PACl-2.1c, a nonsulfated high-basicity PACl (basicity 2.1-2.2) with a high colloidal aluminum content, was larger than that observed with PACl-2.1b, a nonsulfated high-basicity PACl (basicity 2.1-2.2) with a high polymeric aluminum content. In contrast, although extremely high basicity PACls (e.g., PACl-2.7ns, basicity 2.7) effectively removed turbidity and UV260-absorbing natural organic matter and resulted in a very low residual aluminum concentration, the virus removal ratio with PACl-2.7ns was smaller than the ratio with PACl-2.1c at around pH 8, possibly as a result of a reduction of the colloid charge density of the PACl as the basicity was increased from 2.1 to 2.7. Liquid (27)Al NMR analysis revealed that PACl-2.1c contained Al30 species, which was not the case for PACl-2.1b or PACl-2.7ns. This result suggests that Al30 species probably played a major role in virus removal during the coagulation process. In summary, PACl-2.1c, which has high colloidal aluminum content, contains Al30 species, and has a high colloid charge density, removed viruses more efficiently (>4 log10 for infectious viruses) than the other aluminum-based coagulants-including commercially available PACls (basicity 1.5-1.8), alum, and PACl-2.7ns-over the entire tested pH (6-8) and coagulant dosage (0.54-5.4 mg-Al/L) ranges.
Collapse
Affiliation(s)
- N Shirasaki
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan.
| | | | | | | | | | | |
Collapse
|
19
|
Haute SV, Sampers I, Jacxsens L, Uyttendaele M. Selection Criteria for Water Disinfection Techniques in Agricultural Practices. Crit Rev Food Sci Nutr 2013; 55:1529-51. [DOI: 10.1080/10408398.2012.705360] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
|
20
|
Matsushita T, Shirasaki N, Tatsuki Y, Matsui Y. Investigating norovirus removal by microfiltration, ultrafiltration, and precoagulation-microfiltration processes using recombinant norovirus virus-like particles and real-time immuno-PCR. WATER RESEARCH 2013; 47:5819-27. [PMID: 23880217 DOI: 10.1016/j.watres.2013.07.004] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Revised: 07/02/2013] [Accepted: 07/02/2013] [Indexed: 05/03/2023]
Abstract
The removal of microorganisms by drinking water treatment processes has been widely investigated in laboratory-scale experiments using artificially propagated microorganisms. However, this approach cannot be applied to norovirus removal, because this virus does not grow in cell or organ culture, and this fact has hampered our ability to investigate its behavior during drinking water treatment. To overcome this difficulty, our research group previously used recombinant norovirus virus-like particles (rNV-VLPs), which consist of an artificially expressed norovirus capsid protein, in laboratory-scale drinking water treatment experiments. However, the enzyme-linked immunosorbent assay (ELISA) method generally used to detect rNV-VLPs is not sensitive enough to evaluate high removal ratios such as those obtained by ultrafiltration (UF). We therefore developed and applied a real-time immuno-polymerase chain reaction (iPCR) assay for rNV-VLP quantification to investigate norovirus removal by microfiltration (MF), UF, and hybrid precoagulation-MF processes. The rNV-VLP detection limit with the developed iPCR assay was improved at least 1000-fold compared with ELISA. Whereas MF with a nominal pore size of 0.1 μm could not eliminate NV-VLPs, a 4-log reduction was achieved by UF with a molecular weight cutoff of 1 kDa. When MF was combined with precoagulation (≥10 μmol-Fe/L for ferric chloride; ≥20 μmol-Al/L for polyaluminum chloride; ≥40 μmol-Al/L for alum), the performance of the hybrid process in eliminating rNV-VLPs was greater than that achieved by the 1 kDa UF. For all processes, the removal ratios of the bacteriophages MS2 and Qβ were greater than the rNV-VLP removal ratios by 1-2 logs, so neither bacteriophage can be recommended as a possible conservative surrogate for predicting the behavior of native NV during these processes.
Collapse
Affiliation(s)
- Taku Matsushita
- Graduate School of Engineering, Hokkaido University, N13W8, Sapporo 060-8628, Japan.
| | | | | | | |
Collapse
|
21
|
Dika C, Gantzer C, Perrin A, Duval JFL. Impact of the virus purification protocol on aggregation and electrokinetics of MS2 phages and corresponding virus-like particles. Phys Chem Chem Phys 2013; 15:5691-700. [PMID: 23474807 DOI: 10.1039/c3cp44128h] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Previous experimental and theoretical studies have established that electrokinetic and aggregation properties of soft MS2 phages are not only governed by the physico-chemical features of their proteinaceous outer surface but are also significantly impacted by those of their inner RNA component (Dika et al. Appl. Environ. Microbiol., 2011, 14, 4939-4948). These conclusions contradict the recent findings of Nguyen et al. (Soft Matter, 2011, 7, 10449-10456) who reported identical electrokinetic and aggregation characteristics for MS2 and corresponding virus like particles (VLPs) that lack the internal RNA component. We demonstrate here that this contradiction originates from the different purification methods adopted prior to measurements. More generally, we show that stability and electrohydrodynamics of viruses differ according to purification by (i) dialysis, (ii) isopycnic centrifugation in the cesium chloride gradient, and (iii) precipitation using polyethylene glycol (PEG). Methods (i) and (iii) lead to aggregation of MS2 phages at pH ≤ 4 and pH ≤ 6 in 1-100 mM NaNO3 solutions, respectively, while under such conditions aggregation is not observed for MS2 and VLP suspensions prepared according to (ii). In addition, VLPs prepared following methods (i) and (iii) aggregate only at the isoelectric point (pH ~ 3-4) in 1 mM NaNO3 solution. Electrophoretic mobility data of stable MS2 and VLP particles were further examined using a recent formalism for electrokinetics of soft multilayered colloids. The analysis qualitatively shows how the purification protocol may affect either the outer particle surface properties and/or the inner particle content. Finally, the non-DLVO aggregation behavior of MS2 and VLPs purified via the above protocols is discussed in terms of the possible change in corresponding interparticular interactions.
Collapse
Affiliation(s)
- C Dika
- Université de Lorraine, LCPME (Laboratoire de Chimie Physique et Microbiologie pour l'Environnement), UMR 7564, Nancy, France
| | | | | | | |
Collapse
|
22
|
Matsushita T, Suzuki H, Shirasaki N, Matsui Y, Ohno K. Adsorptive virus removal with super-powdered activated carbon. Sep Purif Technol 2013. [DOI: 10.1016/j.seppur.2013.01.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
23
|
Soussan L, Guigui C, Mathe C, Alfenore S, Cabassud C. Enzyme-labeled phages detected by amperometry: A new method to study inline virus retention in membrane processes. AIChE J 2012. [DOI: 10.1002/aic.13788] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Impact of internal RNA on aggregation and electrokinetics of viruses: comparison between MS2 phage and corresponding virus-like particles. Appl Environ Microbiol 2011; 77:4939-48. [PMID: 21622784 DOI: 10.1128/aem.00407-11] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We compare for the first time the electrokinetic and aggregation properties of MS2 phage (pH 2.5 to 7, 1 to 100 mM NaNO(3) electrolyte concentration) with those of the corresponding virus-like particles (VLPs), which lack entirely the inner viral RNA component. In line with our previous work (J. Langlet, F. Gaboriaud, C. Gantzer, and J. F. L. Duval, Biophys. J. 94:3293-3312, 2008), it is found that modifying the content of RNA within the virus leads to very distinct electrohydrodynamic and aggregation profiles for MS2 and MS2 VLPs. Under the given pH and concentration conditions, MS2 VLPs exhibit electrophoretic mobility larger in magnitude than that of MS2, and both have similar isoelectric point (IEP) values (∼4). The electrokinetic results reflect a greater permeability of MS2 VLPs to electroosmotic flow, developed within/around these soft particles during their migration under the action of the applied electrical field. Results also support the presence of some remaining negatively charged component within the VLPs. In addition, MS2 phage systematically forms aggregates at pH values below the IEP, regardless of the magnitude of the solution ionic strength, whereas MS2 VLPs aggregate under the strict condition where the pH is relatively equal to the IEP at sufficiently low salt concentrations (<10 mM). It is argued that the stability of VLPs against aggregation and the differences between electrokinetics of MS2 and corresponding VLPs conform to recently developed formalisms for the stability and electrohydrodynamics of soft multilayered particles. The differences between the surface properties of these two kinds of particles reported here suggest that VLPs may not be appropriate for predicting the behavior of pathogenic viruses in aqueous media.
Collapse
|