1
|
Wang Y, Liu Y, Xue S, Chai F, Zhang S, Yang K, Liu Y, Li J, Yu F. Comparative analysis of bioaerosol emissions: Seasonal dynamics and exposure risks in hospital vs. municipal wastewater treatment systems. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 359:124608. [PMID: 39053807 DOI: 10.1016/j.envpol.2024.124608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 07/21/2024] [Accepted: 07/22/2024] [Indexed: 07/27/2024]
Abstract
Hospital wastewater is known to contain various pathogenic microorganisms and harmful substances. During the hospital wastewater treatment process, the bioaerosols released may encapsulate these pathogens, leading to human infection. This study undertook an investigation to compare the dispersion characteristics and seasonal variations of bioaerosols from hospital and municipal sewage. The results indicated that the airborne bacterial concentration from hospital sewage (119 ± 118 CFU/m3) was higher than municipal sewage (46 ± 19 CFU/m3), with the highest concentration observed in summer. The dominant bacterial genera present in bioaerosols from both sewages were alike, with the proportions varied by sewage types and the structure mainly influenced by seasonal factors. Bacteroides, Escherichia-Shigella and Streptococcus were identified as the most prevalent pathogenic genera in spring, summer and winter bioaerosols, respectively, while Pseudomonas and Acinetobacter were abundant in autumn. Although the non-carcinogenic risk associated with bioaerosols was low (<1), the presence of pathogenic species and their potential synergistic interactions elevated the overall exposure risk. The diffusion modeling results demonstrated that bioaerosol emissions from the surface of hospital sewage can reach up to 10570 CFU/m3 in summer and can spread more than 300 m downwind. The potential pathogenicity of bioaerosols was also highest in summer, which may pose a health hazard to populations located downwind. Therefore, the management and control of bioaerosols from sewage should be strengthened, especially in summer.
Collapse
Affiliation(s)
- Yanjie Wang
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Yang Liu
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Song Xue
- CSCEC SCIMEE Sci.& Tech. Co., Ltd, Chengdu, 610045, PR China.
| | - Fengguang Chai
- School of Ecology and Environment, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Song Zhang
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Kai Yang
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Yifan Liu
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Jinlong Li
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| | - Fangfang Yu
- School of Public Health, Zhengzhou University, Zhengzhou, 450001, PR China.
| |
Collapse
|
2
|
Yu C, Gu L, Wu Z, Chen K, Wu Y, Zhang L, Long Q, Shi H, Xiong Z, Lai B. N-coordinated iron sites dispersed in porous carbon frameworks to activate peroxymonosulfate for efficient sulfisoxazole degradation and real hospital wastewater decontamination. JOURNAL OF HAZARDOUS MATERIALS 2024; 480:136149. [PMID: 39423642 DOI: 10.1016/j.jhazmat.2024.136149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 09/27/2024] [Accepted: 10/11/2024] [Indexed: 10/21/2024]
Abstract
Herein, an N-coordinated Fe site dispersed in porous carbon frameworks (Fe-NC) fabricated from zeolitic imidazolate frameworks encapsulated with iron acetylacetonate (Fe(acac)3 @ZIFs) was employed to activate peroxymonosulfate (PMS) for the attenuation of sulfisoxazole (SIZ) and treating real hospital wastewater. The constructed Fe-NC/PMS system exhibited good catalytic stability for SIZ degradation, maintaining excellent degradation performance over multiple cycles with virtually no leaching. The quenching experiments, electron paramagnetic resonance (EPR) capture analyses, and semi-quantitative measurements showed that singlet oxygen (1O2) and high-valent metal-oxo species were mainly responsible for SIZ degradation by Fe-NC/PMS. Significantly, ultra-performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-Q-TOF-MS/MS) was used to trace 134 pharmaceutical contaminants in real hospital wastewater. Effective degradation was achieved for 87 % of the pharmaceutical contaminants by the Fe-NC/PMS process. Seventy-four pharmaceutical contaminants were eliminated. Taken together, this work successfully established the Fe-NC/PMS technology using the developed iron-based materials and explored its application to real hospital wastewater treatment, providing an eco-friendly and effective strategy for treating wastewater.
Collapse
Affiliation(s)
- Chunxiu Yu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Lingyun Gu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Zelin Wu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Kexin Chen
- Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China
| | - Yi Wu
- Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China
| | - Li Zhang
- Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China
| | - Quan Long
- Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China
| | - Hongle Shi
- Sichuan Province Engineering Technology Research Center of Emerging Contaminants Treatment and Environmental Health, Sichuan Academy of Eco-Environmental Sciences, Chengdu 610041, China
| | - Zhaokun Xiong
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China.
| | - Bo Lai
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| |
Collapse
|
3
|
Ramírez-Coronel AA, Mohammadi MJ, Majdi HS, Zabibah RS, Taherian M, Prasetio DB, Gabr GA, Asban P, Kiani A, Sarkohaki S. Hospital wastewater treatment methods and its impact on human health and environments. REVIEWS ON ENVIRONMENTAL HEALTH 2024; 39:423-434. [PMID: 36805668 DOI: 10.1515/reveh-2022-0216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
The scientific development and economic advances have led to the identification of many pathogenic agents in hospital effluents. Hospital wastewaters are qualitatively similar to municipal wastewaters, with the difference that these wastewaters contain toxic and infectious substances and compounds that can be dangerous for the health of the environment, employees of these centers, and the entire community. Therefore, in the last few years, it has been emphasized that all hospitals and medical and health centers should have a treatment facility for their produced wastewater so that the health of the society and people is not threatened. An issue that is not paid attention to has become one of the environmental problems and concerns of the world today. The present study focused on the investigate hospital wastewater treatment methods and its impact on human health and the environment. In this narrative study, the first literature search was performed with four hundred and twenty-three articles were retrieved based on PubMed, Elsevier, Web of science, Spring, and Google Scholar databases. The results of this study showed that wastewater from hospitals and medical centers can play a significant impress in polluting soil and aquatic environments and spreading infectious diseases. According to the mentioned contents, collection and treatment of hospital wastewater is essential. In addition, if hospital wastewater enters the wastewater collection network without knowing its characteristics or with incomplete treatment and finally enters the municipal wastewater treatment plant. It causes many problems, including disturbing the balance of the biological system of the treatment plant. Purification and disposal of hospital wastewater is considered a vital action based on environmental standards. The results of this study also showed that the treatment methods of this type of hospital wastewater can play a significant role in reducing the spread of diseases caused by hospital wastewater treatment, including infectious diseases. The results of this study can be very useful for politicians, the managers of the Ministry of Energy and Health and the Environmental Organization in choosing the appropriate methods and process to reduce hospital wastewater and increase the efficiency of hospital wastewater treatment plants.
Collapse
Affiliation(s)
- Andrés Alexis Ramírez-Coronel
- Azogues Campus Nursing Career, Health and Behavior Research Group (HBR), Psychometry and Ethology Laboratory, Catholic University of Cuenca, Ecuador
- Doctorate in Psychology, University of Palermo, Buenos Aires, Argentina
- Epidemiology and Biostatistics Research Group, CES University, Colombia
| | - Mohammad Javad Mohammadi
- Department of Environmental Health Engineering, School of Public Health and Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Hasan Sh Majdi
- Department of Chemical Engineering and Petroleum Industries, Al-Mustaqbal University College, Babylon 51001, Iraq
| | - Rahman S Zabibah
- Medical Laboratory Technology Department, College of Medical Technology, The Islamic University, Najaf, Iraq
| | - Masoume Taherian
- Student of Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Diki Bima Prasetio
- Occupational Safety and Health Department, Faculty of Public Health, Universitas Muhammadiyah Semarang, Semarang, Indonesia
| | - Gamal A Gabr
- Department of Pharmacology and Toxicology, College of Pharmacy, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia
- Agricultural Genetic Engineering Research Institute (AGERI), Agricultural Research Center, Giza, Egypt
| | - Parisa Asban
- Student of Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Amin Kiani
- Student of Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Sahar Sarkohaki
- Student of Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| |
Collapse
|
4
|
Męcik M, Stefaniak K, Harnisz M, Korzeniewska E. Hospital and municipal wastewater as a source of carbapenem-resistant Acinetobacter baumannii and Pseudomonas aeruginosa in the environment: a review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:48813-48838. [PMID: 39052110 PMCID: PMC11310256 DOI: 10.1007/s11356-024-34436-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024]
Abstract
The increase in the prevalence of carbapenem-resistant Gram-negative bacteria, in particular Acinetobacter baumannii (CRAB) and Pseudomonas aeruginosa (CRPA), poses a serious threat for public health worldwide. This article reviews the alarming data on the prevalence of infections caused by CRAB and CRPA pathogens and their presence in hospital and municipal wastewater, and it highlights the environmental impact of antibiotic resistance. The article describes the key role of antibiotic resistance genes (ARGs) in the acquisition of carbapenem resistance and sheds light on bacterial resistance mechanisms. The main emphasis was placed on the transfer of ARGs not only in the clinical setting, but also in the environment, including water, soil, and food. The aim of this review was to expand our understanding of the global health risks associated with CRAB and CRPA in hospital and municipal wastewater and to analyze the spread of these micropollutants in the environment. A review of the literature published in the last decade will direct research on carbapenem-resistant pathogens, support the implementation of effective preventive measures and interventions, and contribute to the development of improved strategies for managing this problem.
Collapse
Affiliation(s)
- Magdalena Męcik
- Department of Water Protection Engineering and Environmental Microbiology, Faculty of Geoengineering, University of Warmia and Mazury in Olsztyn, Prawocheńskiego 1, 10-720, Olsztyn, Poland
| | - Kornelia Stefaniak
- Department of Water Protection Engineering and Environmental Microbiology, Faculty of Geoengineering, University of Warmia and Mazury in Olsztyn, Prawocheńskiego 1, 10-720, Olsztyn, Poland
| | - Monika Harnisz
- Department of Water Protection Engineering and Environmental Microbiology, Faculty of Geoengineering, University of Warmia and Mazury in Olsztyn, Prawocheńskiego 1, 10-720, Olsztyn, Poland
| | - Ewa Korzeniewska
- Department of Water Protection Engineering and Environmental Microbiology, Faculty of Geoengineering, University of Warmia and Mazury in Olsztyn, Prawocheńskiego 1, 10-720, Olsztyn, Poland.
| |
Collapse
|
5
|
Seewald M, Nielinger L, Alker K, Behnke JS, Wycisk V, Urner LH. Detergent Chemistry Modulates the Transgression of Planetary Boundaries including Antimicrobial Resistance and Drug Discovery. Angew Chem Int Ed Engl 2024; 63:e202403833. [PMID: 38619211 DOI: 10.1002/anie.202403833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/13/2024] [Accepted: 03/13/2024] [Indexed: 04/16/2024]
Abstract
Detergent chemistry enables applications in the world today while harming safe operating spaces that humanity needs for survival. Aim of this review is to support a holistic thought process in the design of detergent chemistry. We harness the planetary boundary concept as a framework for literature survey to identify progresses and knowledge gaps in context with detergent chemistry and five planetary boundaries that are currently transgressed, i.e., climate, freshwater, land system, novel entities, biosphere integrity. Our survey unveils the status of three critical challenges to be addressed in the years to come, including (i) the implementation of a holistically, climate-friendly detergent industry; (ii) the alignment of materialistic and social aspects in creating technical solutions by means of sustainable chemistry; (iii) the development of detergents that serve the purpose of applications but do not harm the biosphere in their role as novel entities. Specifically, medically relevant case reports revealed that even the most sophisticated detergent design cannot sufficiently accelerate drug discovery to outperform the antibiotic resistance development that detergents simultaneously promote as novel entities. Safe operating spaces that humanity needs for its survival may be secured by directing future efforts beyond sustainable chemistry, resource efficiency, and net zero emission targets.
Collapse
Affiliation(s)
- Marc Seewald
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| | - Lena Nielinger
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| | - Katharina Alker
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| | - Jan-Simon Behnke
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| | - Virginia Wycisk
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| | - Leonhard H Urner
- TU Dortmund University, Department of Chemistry and Chemical Biology, Otto-Hahn-Str. 6, 44227, Dortmund, Germany
| |
Collapse
|
6
|
He D, Li J, Yu W, Zhang Y, Wang B, Wang T, Yang H, Zhang Y, Chen W, Li Y, Feng F, Hou LA. Deciphering the removal of antibiotics and the antibiotic resistome from typical hospital wastewater treatment systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 926:171806. [PMID: 38508266 DOI: 10.1016/j.scitotenv.2024.171806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/15/2024] [Accepted: 03/16/2024] [Indexed: 03/22/2024]
Abstract
Hospital wastewater treatment systems (HWTSs) are a significant source and reservoir of antibiotic resistance genes (ARGs) and a crucial hub for transmitting ARGs from clinical to natural environments. However, there is a lack of research on the antibiotic resistome of clinical wastewater in HWTSs. In this study, we used metagenomics to analyze the prevalence and abundance of ARGs in five typical HWTSs. A total of 17 antibiotics from six categories were detected in the five HWTSs; β-lactam antibiotics were found at the highest concentrations, with up to 4074.08 ng·L-1. We further found a total of 21 ARG types and 1106 subtypes of ARGs with the highest percentage of multi-drug resistance genes (evgS, msbA, arlS, and baeS). The most abundant last-resort ARGs were mcr, which were detected in 100 % of the samples. HWTSs effluent is a major pathway for the transmission of last-resort ARGs into urban wastewater networks. The removal of antibiotics, antibiotic-resistant bacteria, and ARGs from HWTSs was mainly achieved by tertiary treatment, i.e., chlorine disinfection, but antibiotics and ARGs were still present in the HWTSs effluent or even increased after treatment. Moreover, antibiotics and heavy metals (especially mercury) in hospital effluents can exert selective pressure for antibiotic resistance, even at low concentrations. Qualitative analyses based on metagenome-assembled genome analysis revealed that the putative hosts of the identified ARGs are widely distributed among Pseudomonas, Acidovorax, Flavobacterium, Polaromonas, and Arcobacter. Moreover, we further assessed the clinical availability of ARGs and found that multidrug ARGs had the highest clinical relevance values. This study provides new impulses for monitoring and removing antibiotics and ARGs in the hospital sewage treatment process.
Collapse
Affiliation(s)
- Dahai He
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China
| | - Jiang Li
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China; Guizhou Karst Environmental Ecosystems Observation and Research Station, Ministry of Education, Guiyang 550025, China.
| | - Weihai Yu
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China
| | - Yingyuan Zhang
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China; Guizhou Academy of Testing and Analysis, Guiyang 550000, China
| | - Bin Wang
- College of Civil Engineering, Guizhou University, Guiyang 550025, China
| | - Tao Wang
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China; Guizhou Karst Environmental Ecosystems Observation and Research Station, Ministry of Education, Guiyang 550025, China
| | - Huaikai Yang
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China
| | - Yuntao Zhang
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China
| | - Weijie Chen
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China
| | - Yancheng Li
- College of Resources and Environmental Engineering, Key Laboratory of Karst Georesources and Environment, Ministry of Education, Guizhou University, Guiyang 550025, China; Guizhou Karst Environmental Ecosystems Observation and Research Station, Ministry of Education, Guiyang 550025, China
| | - Faming Feng
- Chutian Liangjiang Environment Co., LTD, Guiyang 550000, China
| | - Li-An Hou
- State Key Laboratory of Water Environment Simulation, School of Environment, Beijing Normal University, Beijing 100875, China
| |
Collapse
|
7
|
Ramezanzadeh S, Esmaeilzadeh F, Mowla D, Elhambakhsh A, Kanani M. Insight into the application of supercritical water oxidation for dichlorvos degradation: experimental and simulation aspects. ENVIRONMENTAL TECHNOLOGY 2023; 44:4113-4122. [PMID: 35587737 DOI: 10.1080/09593330.2022.2080000] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 04/05/2022] [Indexed: 06/15/2023]
Abstract
Dichlorvos or 2,2-dichlorovinyl dimethyl phosphate (DDVP) ( C 4 H 7 C l 2 O 4 P ) is a chlorinated organophosphorus pesticide, which is frequently detected in agricultural wastewater. Herein, a batch reactor was used to carry out the supercritical water oxidation (SCWO) of a synthetic wastewater containing dichlorvos as a very hazardous agricultural pollutant. To do so, the impact of four operating parameters including dichlorvos concentration (100-500 ppm), oxidant coefficient (0.7-2), temperature (300-500°C) and time (0-100 s) on dichlorvos removal was optimized by the response surface method (RSM). According to the obtained results, at optimal conditions (i.e. initial concentration of dichlorvos 107.5 ppm, oxidation ratio 1.9234, temperature 419.9°C and time 79.94 s), as an index for dichlorvos removal, the chemical oxygen demand (COD) was found to be about 96.34%. Also, the results of high-performance liquid chromatography test showed that dichloroacetaldehyde (C2CL2H2O) and dichloroacetic acid (C2CL2H2O2) were created as intermediate substances during the dichlorvos degradation. Further, the molecular dynamics simulation was performed using ReaxFF force field to show the reaction path and products obtained in each step of the dichlorvos removal. Finally, as an indication, the simulation results indicated a good coordination with the experimental results.
Collapse
Affiliation(s)
- Shiva Ramezanzadeh
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, Shiraz, Iran
| | - Feridun Esmaeilzadeh
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, Shiraz, Iran
| | - Dariush Mowla
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, Shiraz, Iran
| | - Abbas Elhambakhsh
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, Shiraz, Iran
| | - Mansour Kanani
- Department of Materials Science and Engineering, School of Engineering, Shiraz University, Shiraz, Iran
| |
Collapse
|
8
|
El-Amaireh NAA, Al-Zoubi H, Al-Khashman OA. Hospital waste incinerator ash: characteristics, treatment techniques, and applications (A review). JOURNAL OF WATER AND HEALTH 2023; 21:1686-1702. [PMID: 38017599 PMCID: wh_2023_299 DOI: 10.2166/wh.2023.299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
The amount of medical waste generated has increased enormously since the COVID-19 outbreak. An incineration process is the main method that is usually used to treat this waste, causing an increase in both medical waste bottom ash (MWBA) and medical waste fly ash (MWFA). In this work, the physical and chemical characteristics of MWFA and MWBA were reviewed. This ash contains high levels of polychlorinated dibenzo-p-dioxin (PCDD), dibenzofurans (PCDFs), and heavy metals. Furthermore, medical waste ash appears to have high leachability in the toxicity characteristics leaching procedure (TCLP) test and the European standard test (EN 12457). Owing to its toxicity, medical ash can be treated using various methods prior to disposal based on the covered review. These techniques include chemical, supercritical fluid, cement-based, melting, microwave, and mechanochemical techniques. The shortcomings of some of these treatment methods have been identified, such as the emission of high levels of chlorine from the melting technique, limited applications of the flotation method on the industrial scale, long-term stability of leachate treated by cement-based methods that have not been confirmed yet, and high energy consumption in the supercritical technique. This review also covers possible applications of medical waste ash in cement production, agriculture, and road construction.
Collapse
Affiliation(s)
| | - Habis Al-Zoubi
- Department of Chemical Engineering, College of Engineering, Al-Hussein Bin Talal University, Ma'an 71111, Jordan
| | - Omar Ali Al-Khashman
- Department of Environmental Engineering, College of Engineering, Al-Hussein Bin Talal University, Ma'an 71111, Jordan
| |
Collapse
|
9
|
Zhang M, Liu J, Hu N, Fang Q, Zhang D, Qiang Z, Pan X. Cascade capture, oxidization and inactivation for removing multi-species pollutants, antimicrobial resistance and pathogenicity from hospital wastewater. JOURNAL OF HAZARDOUS MATERIALS 2023; 457:131730. [PMID: 37269564 DOI: 10.1016/j.jhazmat.2023.131730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 04/29/2023] [Accepted: 05/27/2023] [Indexed: 06/05/2023]
Abstract
As reservoirs of pathogens, antimicrobial resistant microorganisms and a wide variety of pollutants, hospital wastewaters (HWWs) need to be effectively treated before discharge. This study employed the functionalized colloidal microbubble technology as one-step fast HWW treatment. Inorganic coagulant (monomeric Fe(III)-coagulant or polymeric Al(III)-coagulant) and ozone were used as surface-decorator and gaseous core modifier, respectively. The Fe(III)- or Al(III)-modified colloidal gas (or, ozone) microbubbles (Fe(III)-CCGMBs, Fe(III)-CCOMBs, Al(III)-CCGMBs and Al(III)-CCOMBs) were constructed. Within 3 min, CCOMBs decreased CODCr and fecal coliform concentration to the levels meeting the national discharge standard for medical organization. Regrowth of bacteria was inhibited and biodegradability of organics was increased after the simultaneous oxidation and cell-inactivation process. The metagenomics analysis further reveals that Al(III)-CCOMBs performed best in capturing the virulence genes, antibiotic resistance genes and their potential hosts. The horizontal transfer of those harmful genes could be effectively hampered thanks to the removal of mobile genetic elements. Interestingly, the virulence factors of adherence, micronutrient uptake/acquisition and phase invasion could facilitate the interface-dominated capture. Featured as cascade processes of capture, oxidation and inactivation in the one-step operation, the robust Al(III)-CCOMB treatment is recommended for the HWW treatment and the protection of downstream aquatic environment.
Collapse
Affiliation(s)
- Ming Zhang
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
| | - Jiayuan Liu
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
| | - Na Hu
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
| | - Qunkai Fang
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
| | - Daoyong Zhang
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China.
| | - Zhimin Qiang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 18 Shuang-qing Road, Beijing 100085, China
| | - Xiangliang Pan
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
| |
Collapse
|
10
|
Hu M, Li Z, Huang X, Chen M, Hu ZT, Tang S, Chou IM, Pan Z, Wang Q, Wang J. Catalytic supercritical water oxidation of o-chloroaniline over Ru/rGO: Reaction variables, conversion pathways and nitrogen distribution. CHEMOSPHERE 2023; 333:138907. [PMID: 37169091 DOI: 10.1016/j.chemosphere.2023.138907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/22/2023] [Accepted: 05/08/2023] [Indexed: 05/13/2023]
Abstract
To ascertain the reaction variables on o-chloroaniline (o-ClA) mineralization, total nitrogen (TN) removal rate, and N-species distribution, o-ClA was subjected to catalytic supercritical water oxidation (CSCWO) in a fused quartz tube reactor (FQTR). The findings demonstrated that when the temperature, reaction time, and excess oxidant were 400 °C, 90 min, and 150%, respectively, the mineralization rate of o-ClA could reach more than 95%. Moreover, potential degradation pathways of o-ClA in supercritical water oxidation (SCWO) was proposed according to the GC-MS results. TN removal rate is significantly impacted by Ru/rGO, despite the fact that its catalytic effect on the mineralization of o-ClA was not particularly noteworthy. Compared with no catalyst, the TN removal rate of o-ClA obviously increased from 44.1% to 90.3% at 400 °C, 10 wt% Ru loading, 90 min and 200% excess oxidant. In addition, N-species distribution in SCWO and CSCWO were also investigated. Results indicated that the Ru/rGO catalyst could accelerate the oxidation of ammonia-N and convert it to nitrate-N, promoting N2 generation. Finally, the possible N transformation pathway in CSCWO of o-ClA was proposed. As a result, this work offers fundamental information about o-ClA catalytic oxidation removal in the SCWO process.
Collapse
Affiliation(s)
- Mian Hu
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Zhibing Li
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Xiaotong Huang
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Meiqi Chen
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Zhong-Ting Hu
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Suqin Tang
- Hangzhou Environmental Group Co., Ltd, Zhejiang, China
| | - I-Ming Chou
- CAS Key Laboratory of Experimental Study Under Deep-sea Extreme Conditions, Institute of Deep-sea Science and Engineering, Chinese Academy of Sciences, Sanya, 572000, Hainan, China
| | - Zhiyan Pan
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China
| | - Qi Wang
- Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, China.
| | - Junliang Wang
- College of Environment, Zhejiang University of Technology, Hangzhou, 310032, Zhejiang, China.
| |
Collapse
|
11
|
Dias IM, Mourão LC, Andrade LA, Souza GBM, Viana JCV, Oliveira SB, Alonso CG. Degradation of antibiotic amoxicillin from pharmaceutical industry wastewater into a continuous flow reactor using supercritical water gasification. WATER RESEARCH 2023; 234:119826. [PMID: 36881954 DOI: 10.1016/j.watres.2023.119826] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 02/21/2023] [Accepted: 02/27/2023] [Indexed: 06/18/2023]
Abstract
In recent years the concern with emerging pollutants in water has become more prominent, especially pharmaceutical residues, such as antibiotics due to the influence to increase antibacterial resistance. Further, conventional wastewater treatment methods have not demonstrated efficiency for the complete degradation of these compounds, or they have limitations to treat a large volume of waste. In this sense, this study aims to investigate the degradation of amoxicillin, one of the most prescribed antibiotics, in wastewater via supercritical water gasification (SCWG) using a continuous flow reactor. For this purpose, the process operating conditions of temperature, feed flow rate, and concentration of H2O2 was evaluated using Experimental Design and Response Surface Methodology techniques and optimized by Differential Evolution methodology. Total organic carbon (TOC) removal, chemical oxygen demand (COD) degradability, reaction time, amoxicillin degradation rate, toxicity of degradation by-products, and gaseous products were evaluated. The use of SCWG for treatment achieved 78.4% of the TOC removal for the industrial wastewater. In the gaseous products, hydrogen was the majority component. Furthermore, high-performance liquid chromatography analyses demonstrated that the antibiotic amoxicillin was degraded. For a mass flow rate of 15 mg/min of amoxicillin fed into the reaction system, 14.4 mg/min was degraded. Toxicity tests with microcrustacean Artemia salina showed slight toxicity to treated wastewater. Despite that, the outcomes reveal the SCWG has great potential to degrade amoxicillin and may be applied to treat several pharmaceutical pollutants. Aside from this, carbon-rich effluents may lead to a significant energy gaseous product, especially, hydrogen and syngas.
Collapse
Affiliation(s)
- Isabela M Dias
- Universidade Federal de Goias (UFG), Instituto de Química, Av. Esperança s/n, Campus Samambaia, Goiania, Goias CEP 74690-900, Brazil
| | - Lucas C Mourão
- Universidade Federal de Goias (UFG), Instituto de Química, Av. Esperança s/n, Campus Samambaia, Goiania, Goias CEP 74690-900, Brazil
| | - Laiane A Andrade
- Universidade Federal do Mato Grosso do Sul (UFMS), Av. Rosilene Lima Oliveira, 64, Jardim Universitário, Nova Andradina, Mato Grosso do Sul CEP 79750-000, Brazil
| | - Guilherme B M Souza
- Universidade Federal de Goias (UFG), Instituto de Química, Av. Esperança s/n, Campus Samambaia, Goiania, Goias CEP 74690-900, Brazil
| | - Júlio C V Viana
- Universidade Federal de Goias (UFG), Instituto de Química, Av. Esperança s/n, Campus Samambaia, Goiania, Goias CEP 74690-900, Brazil; Universidade Federal do Tocantins (UFT), Chácara 69-72 Rua Badejos, Lote 7s/n Câmpus Jardim Sevilha, Gurupi, Tocantins CEP 77410-530, Brazil
| | - Sergio B Oliveira
- Instituto Federal de Goiás (IFG), Rua 75 no. 46, Goiânia, Goias CEP 74055-110, Brazil
| | - Christian G Alonso
- Universidade Federal de Goias (UFG), Instituto de Química, Av. Esperança s/n, Campus Samambaia, Goiania, Goias CEP 74690-900, Brazil.
| |
Collapse
|
12
|
khalidi-idrissi A, Madinzi A, Anouzla A, Pala A, Mouhir L, Kadmi Y, Souabi S. Recent advances in the biological treatment of wastewater rich in emerging pollutants produced by pharmaceutical industrial discharges. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY : IJEST 2023; 20:1-22. [PMID: 37360558 PMCID: PMC10019435 DOI: 10.1007/s13762-023-04867-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 12/19/2022] [Accepted: 02/22/2023] [Indexed: 06/28/2023]
Abstract
Pharmaceuticals and personal care products present potential risks to human health and the environment. In particular, wastewater treatment plants often detect emerging pollutants that disrupt biological treatment. The activated sludge process is a traditional biological method with a lower capital cost and limited operating requirements than more advanced treatment methods. In addition, the membrane bioreactor combines a membrane module and a bioreactor, widely used as an advanced method for treating pharmaceutical wastewater with good pollution performance. Indeed, the fouling of the membrane remains a major problem in this process. In addition, anaerobic membrane bioreactors can treat complex pharmaceutical waste while recovering energy and producing nutrient-rich wastewater for irrigation. Wastewater characterizations have shown that wastewater's high organic matter content facilitates the selection of low-cost, low-nutrient, low-surface-area, and effective anaerobic methods for drug degradation and reduces pollution. However, to improve the biological treatment, researchers have turned to hybrid processes in which all physical, chemical, and biological treatment methods are integrated to remove various emerging contaminants effectively. Hybrid systems can generate bioenergy, which helps reduce the operating costs of the pharmaceutical waste treatment system. To find the most effective treatment technique for our research, this work lists the different biological treatment techniques cited in the literature, such as activated sludge, membrane bioreactor, anaerobic treatment, and hybrid treatment, combining physicochemical and biological techniques.
Collapse
Affiliation(s)
- A. khalidi-idrissi
- Laboratory of Process Engineering and Environment, Faculty of Science and Technology, Mohammedia, University Hassan II of Casablanca, BP. 146, Mohammedia, Morocco
| | - A. Madinzi
- Laboratory of Process Engineering and Environment, Faculty of Science and Technology, Mohammedia, University Hassan II of Casablanca, BP. 146, Mohammedia, Morocco
| | - A. Anouzla
- Laboratory of Process Engineering and Environment, Faculty of Science and Technology, Mohammedia, University Hassan II of Casablanca, BP. 146, Mohammedia, Morocco
| | - A. Pala
- Environmental Research and Development Center (CEVMER), Dokuz Eylul University, Izmir, Turkey
| | - L. Mouhir
- Laboratory of Process Engineering and Environment, Faculty of Science and Technology, Mohammedia, University Hassan II of Casablanca, BP. 146, Mohammedia, Morocco
| | - Y. Kadmi
- CNRS, UMR 8516 - LASIR, University Lille, 59000 Lille, France
| | - S. Souabi
- Laboratory of Process Engineering and Environment, Faculty of Science and Technology, Mohammedia, University Hassan II of Casablanca, BP. 146, Mohammedia, Morocco
| |
Collapse
|
13
|
Fatimazahra S, Latifa M, Laila S, Monsif K. Review of hospital effluents: special emphasis on characterization, impact, and treatment of pollutants and antibiotic resistance. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:393. [PMID: 36780024 PMCID: PMC9923651 DOI: 10.1007/s10661-023-11002-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
Health care institutions generate large volumes of liquid effluents from specific activities related to healthcare, analysis, and research. Their direct discharge into the environment has various negative effects on aquatic environments and human health, due to their high organic matter charges and the presence of various emerging contaminants such as disinfectants, drugs, bacteria, viruses, and parasites. Moreover, hospital effluents, by carrying antibiotics, contribute to the development of antibiotic-resistant microorganisms in the environment. This resistance has become a global issue that manifests itself variously in different countries, causing the transmission of different infections. In this respect, an effort is provided to protect water resources by current treatment methods that imply physical-chemical processes such as adsorption and advanced oxidation processes, biological processes such as activated sludge and membrane bioreactors and other hybrid techniques. The purpose of this review is to improve the knowledge on the composition and impact of hospital wastewater on man and the environment, highlighting the different treatment techniques appropriate to this type of disposal before discharge into the environment.
Collapse
Affiliation(s)
- Sayerh Fatimazahra
- Process Engineering and Environment Laboratory, Faculty of Science and Technology of Mohammedia, Hassan II University, Casablanca, Morocco
| | - Mouhir Latifa
- Process Engineering and Environment Laboratory, Faculty of Science and Technology of Mohammedia, Hassan II University, Casablanca, Morocco
| | - Saafadi Laila
- Process Engineering and Environment Laboratory, Faculty of Science and Technology of Mohammedia, Hassan II University, Casablanca, Morocco
| | - Khazraji Monsif
- Process Engineering and Environment Laboratory, Faculty of Science and Technology of Mohammedia, Hassan II University, Casablanca, Morocco
| |
Collapse
|
14
|
Ateş H, Argun ME. Fate of phthalate esters in landfill leachate under subcritical and supercritical conditions and determination of transformation products. WASTE MANAGEMENT (NEW YORK, N.Y.) 2023; 155:292-301. [PMID: 36410146 DOI: 10.1016/j.wasman.2022.11.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 10/16/2022] [Accepted: 11/10/2022] [Indexed: 06/16/2023]
Abstract
The hypothesis of this study is that the complex organic load of landfill leachate could be reduced by supercritical water oxidation (SCWO) in a single stage, but this operation could lead to the formation of some undesired by-products of phthalate esters (PAEs). In this context, the fate of selected PAEs, butyl benzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP), was investigated during the oxidation of leachate under subcritical and supercritical conditions. Experiments were conducted at various temperatures (250-500 °C), pressures (10-35 MPa), residence times (2-18 min) and dimensionless oxidant doses (DOD: 0.2-2.3). The SCWO process decreased the leachate's chemical oxygen demand (COD) from 34,400 mg/L to 1,120 mg/L (97%). Removal efficiencies of DEHP and DNOP with longer chains were higher than BBP. The DEHP, DNOP and BBP compounds were removed in the range of -35 to 100%, -18 to 92%, and 28 to 36%, respectively, by the SCWO process. Many non-target PAEs were qualitatively detected in the raw leachate apart from the selected PAEs. Besides, 97% of total PAEs including both target and non-target PAEs was mineralized at 15 MPa, 300 °C and 5 min. Although PAEs were highly mineralized during SCWO of the leachate, aldehyde, ester, amide and amine-based phthalic substances were frequently detected as by-products. These by-products have transformed into higher molecular weight by-products with binding reactions as a result of complex SCWO process chemistry. It has also been determined that some non-target PAEs such as 1,2-benzenedicarboxylic acid bis(2-methylpropyl)ester and bis(2-ethylhexyl) isophthalate can transform to the DEHP. Therefore, the suggested pathway in this study for PAEs degradation during the SCWO of the leachate includes substitution and binding reactions as well as an oxidation reaction.
Collapse
Affiliation(s)
- Havva Ateş
- Konya Technical University, Faculty of Engineering and Natural Science, Department of Environmental Engineering, Türkiye.
| | - Mehmet Emin Argun
- Konya Technical University, Faculty of Engineering and Natural Science, Department of Environmental Engineering, Türkiye.
| |
Collapse
|
15
|
Pariente MI, Segura Y, Álvarez-Torrellas S, Casas JA, de Pedro ZM, Diaz E, García J, López-Muñoz MJ, Marugán J, Mohedano AF, Molina R, Munoz M, Pablos C, Perdigón-Melón JA, Petre AL, Rodríguez JJ, Tobajas M, Martínez F. Critical review of technologies for the on-site treatment of hospital wastewater: From conventional to combined advanced processes. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 320:115769. [PMID: 35944316 DOI: 10.1016/j.jenvman.2022.115769] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 07/12/2022] [Accepted: 07/14/2022] [Indexed: 06/15/2023]
Abstract
This review aims to assess different technologies for the on-site treatment of hospital wastewater (HWW) to remove pharmaceutical compounds (PhCs) as sustances of emerging concern at a bench, pilot, and full scales from 2014 to 2020. Moreover, a rough characterisation of hospital effluents is presented. The main detected PhCs are antibiotics and psychiatric drugs, with concentrations up to 1.1 mg/L. On the one hand, regarding the presented technologies, membrane bioreactors (MBRs) are a good alternative for treating HWW with PhCs removal values higher than 80% in removing analgesics, anti-inflammatories, cardiovascular drugs, and some antibiotics. Moreover, this system has been scaled up to the pilot plant scale. However, some target compounds are still present in the treated effluent, such as psychiatric and contrast media drugs and recalcitrant antibiotics (erythromycin and sulfamethoxazole). On the other hand, ozonation effectively removes antibiotics found in the HWW (>93%), and some studies are carried out at the pilot plant scale. Even though, some families, such as the X-ray contrast media, are recalcitrant to ozone. Other advanced oxidation processes (AOPs), such as Fenton-like or UV treatments, seem very effective for removing pharmaceuticals, Antibiotic Resistance Bacteria (ARBs) and Antibiotic Resistance Genes (ARGs). However, they are not implanted at pilot plant or full scale as they usually consider extra reactants such as ozone, iron, or UV-light, making the scale-up of the processes a challenging task to treat high-loading wastewater. Thus, several examples of biological wastewater treatment methods combined with AOPs have been proposed as the better strategy to treat HWW with high removal of PhCs (generally over 98%) and ARGs/ARBs (below the detection limit) and lower spending on reactants. However, it still requires further development and optimisation of the integrated processes.
Collapse
Affiliation(s)
- M I Pariente
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain.
| | - Y Segura
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| | - S Álvarez-Torrellas
- Department of Chemical Engineering and Materials, Universidad Complutense de Madrid, Av/ Complutense s/n, 28040, Madrid, Spain
| | - J A Casas
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - Z M de Pedro
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - E Diaz
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - J García
- Department of Chemical Engineering and Materials, Universidad Complutense de Madrid, Av/ Complutense s/n, 28040, Madrid, Spain
| | - M J López-Muñoz
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| | - J Marugán
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| | - A F Mohedano
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - R Molina
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| | - M Munoz
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - C Pablos
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| | - J A Perdigón-Melón
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering. University of Alcalá, Ctra Madrid-Barcelona, 33,600, 28871, Alcalá de Henares, Madrid, Spain
| | - A L Petre
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering. University of Alcalá, Ctra Madrid-Barcelona, 33,600, 28871, Alcalá de Henares, Madrid, Spain
| | - J J Rodríguez
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - M Tobajas
- Department of Chemical Engineering, Faculty of Science, Universidad Autónoma de Madrid, Campus de Cantoblanco, C/ Francisco Tomás y, Valiente, 7, 28049, Madrid, Spain
| | - F Martínez
- Department of Chemical and Environmental Technology, ESCET, Rey Juan Carlos University, C/Tulipán s/n, 28933, Móstoles, Madrid, Spain
| |
Collapse
|
16
|
Yu Y, Xiong Z, Huang B, Wang X, Du Y, He C, Liu Y, Yao G, Lai B. Synchronous removal of pharmaceutical contaminants and inactivation of pathogenic microorganisms in real hospital wastewater by electro-peroxone process. ENVIRONMENT INTERNATIONAL 2022; 168:107453. [PMID: 35961271 DOI: 10.1016/j.envint.2022.107453] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 07/07/2022] [Accepted: 08/02/2022] [Indexed: 06/15/2023]
Abstract
Herein, a highly efficient electro-peroxone (E-peroxone) process with graphite felt as ozone diffusion electrode (ODE) was developed for the synchronous removal of pharmaceutical contaminants and inactivation of pathogenic microorganisms in real hospital wastewater. Under optimal conditions, the total organic carbon (TOC) removal rate of real hospital wastewater could reach 93.9%. Importantly, 126 pharmaceutical compounds (antibiotics, antivirals, analgesics, antiepileptics, hormones, and others) were determined in hospital wastewater by using ultra performance liquid chromatography combined with quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS/MS). 110 pharmaceutical compounds could be efficiently degraded in E-peroxone system. Concurrently, the microbial community analysis through high-throughput sequencing showed that E-peroxone process exhibited an excellent disinfection effect in real hospital wastewater. Escherichia coli as a bacterial indicator could be completely inactivated in E-peroxone process·H2O2 and hydroxyl radical (OH) were found in E-peroxone system based on the results of chemical probe experiments and electron paramagnetic resonance (EPR) analysis. The in-situ generation of H2O2 from cathodic oxygen reduction in ODE can react with ozone to produce OH, and realize high efficiencies for the elimination of pharmaceutical and sterilization. This work established a green and effective way without extra addition of chemical reagents for high-efficiency treatment of real hospital wastewater.
Collapse
Affiliation(s)
- Yahan Yu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China
| | - Zhaokun Xiong
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China; Water Safety and Water Pollution Control Engineering Technology Research Center in Sichuan Province, Haitian Water Group, China.
| | - Bingkun Huang
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China
| | - Xinhao Wang
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China
| | - Ye Du
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China
| | - Chuanshu He
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China; Water Safety and Water Pollution Control Engineering Technology Research Center in Sichuan Province, Haitian Water Group, China
| | - Yang Liu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China; Water Safety and Water Pollution Control Engineering Technology Research Center in Sichuan Province, Haitian Water Group, China
| | - Gang Yao
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Institute of Environmental Engineering, RWTH Aachen University, Germany
| | - Bo Lai
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China; Yibin Institute of Industrial Technology, Sichuan University, Yibin, China; Water Safety and Water Pollution Control Engineering Technology Research Center in Sichuan Province, Haitian Water Group, China.
| |
Collapse
|
17
|
Al-Atta A, Sher F, Hazafa A, Zafar A, Iqbal HMN, Karahmet E, Lester E. Supercritical water oxidation of phenol and process enhancement with in situ formed Fe 2O 3 nano catalyst. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:61896-61904. [PMID: 34559388 PMCID: PMC9464123 DOI: 10.1007/s11356-021-16390-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 09/03/2021] [Indexed: 02/07/2023]
Abstract
During the past few decades, the treatment of hazardous waste and toxic phenolic compounds has become a major issue in the pharmaceutical, gas/oil, dying, and chemical industries. Considering polymerization and oxidation of phenolic compounds, supercritical water oxidation (SCWO) has gained special attention. The present study objective was to synthesize a novel in situ Fe2O3nano-catalyst in a counter-current mixing reactor by supercritical water oxidation (SCWO) method to evaluate the phenol oxidation and COD reduction at different operation conditions like oxidant ratios and concentrations. Synthesized nano-catalyst was characterized by powder X-ray diffraction (XRD) and transmission electron microscope (TEM). TEM results revealed the maximum average particle size of 26.18 and 16.20 nm for preheated and non-preheated oxidant configuration, respectively. XRD showed the clear peaks of hematite at a 2θ value of 24, 33, 35.5, 49.5, 54, 62, and 64 for both catalysts treated preheated and non-preheated oxidant configurations. The maximum COD reduction and phenol oxidation of about 93.5% and 99.9% were observed at an oxidant ratio of 1.5, 0.75 s, 25 MPa, and 380 °C with a non-preheated H2O2 oxidant, while in situ formed Fe2O3nano-catalyst showed the maximum phenol oxidation of 99.9% at 0.75 s, 1.5 oxidant ratio, 25 MPa, and 380 °C. Similarly, in situ formed Fe2O3 catalyst presented the highest COD reduction of 97.8% at 40 mM phenol concentration, 1.0 oxidant ratio, 0.75 s residence time, 380 °C, and 25 MPa. It is concluded and recommended that SCWO is a feasible and cost-effective alternative method for the destruction of contaminants in water which showed the complete conversion of phenol within less than 1 s and 1.5 oxidant ratio.
Collapse
Affiliation(s)
- Ammar Al-Atta
- Department of Chemical and Environmental Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
- Oil and Gas Refinery Department, Al-Farabi University College, Baghdad, Iraq
| | - Farooq Sher
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, UK.
| | - Abu Hazafa
- International Society of Engineering Science and Technology, Nottingham, UK
- Department of Biochemistry, University of Agriculture, Faisalabad, 38040, Pakistan
| | - Ayesha Zafar
- International Society of Engineering Science and Technology, Nottingham, UK
- Institute of Biochemistry and Biotechnology, Faculty of Biosciences, University of Veterinary and Animal Sciences, Lahore, Pakistan
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, 64849, Monterrey, Mexico
| | - Emina Karahmet
- Department of Biochemistry, Faculty of Pharmacy, University of Modern Science, 88000, Mostar, Bosnia and Herzegovina
| | - Edward Lester
- Department of Chemical and Environmental Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| |
Collapse
|
18
|
A Review of Hybrid Process Development Based on Electrochemical and Advanced Oxidation Processes for the Treatment of Industrial Wastewater. INTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING 2022. [DOI: 10.1155/2022/1105376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
Nowadays, increased human activity, industrialization, and urbanization result in the production of enormous quantities of wastewater. Generally, physicochemical and biological methods are employed to treat industrial effluent and wastewater and have demonstrated high efficacy in removing pollutants. However, some industrial effluent and wastewater contain contaminants that are extremely difficult to remove using standard physicochemical and biological processes. Previously, electrochemical and hybrid advanced oxidation processes (AOP) were considered a viable and promising alternative for achieving an adequate effluent treatment strategy in such instances. These processes rely on the production of hydroxyl radicals, which are highly reactive oxidants that efficiently break down contaminants found in wastewater and industrial effluent. This review focuses on the removal of contaminants from industrial effluents and wastewater through the integration of electrochemical and advanced oxidation techniques. These processes include electrooxidation, electrocoagulation/electroflocculation, electroflotation, photo-Fenton, ozone-photo-Fenton, sono-photo-Fenton, photo-electro-Fenton, ozone/electrocoagulation, sono-electrocoagulation, and peroxi/photo/electrocoagulation. The data acquired from over 150 published articles, most of which were laboratory experiments, demonstrated that the hybrid process is more effective in removing contaminants from industrial effluent and wastewater than standalone processes.
Collapse
|
19
|
Ghasemi MN, Esmaeilzadeh F, Mowla D, Elhambakhsh A. Treatment of methyldiethanolamine wastewater using subcritical and supercritical water oxidation: parameters study, process optimization and degradation mechanism. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:57688-57702. [PMID: 35355177 DOI: 10.1007/s11356-022-19910-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 03/22/2022] [Indexed: 06/14/2023]
Abstract
In this examination, sub/supercritical water oxidation (SCWO) in a batch reactor was employed to degrade methyldiethanolamine (MDEA). To do so, the impact of different operating parameters including temperature (300-500 °C), time (0-100 s), initial MDEA concentration (1000-4000 ppm), oxidant coefficient (0.7-2), and pH (7.3-9.5) on MDEA degradation was separately and together investigated. Subsequently, the response surface method (RSM) was applied to optimize the operating condition of MDEA degradation. Based on the obtained results, a maximum amount of 97.4% MDEA degradation was achieved at the initial MDEA concentration of 1095 ppm in optimal condition (i.e., oxidant coefficient: 1.913, temperature: 472 °C and residence time: about 17 s). Furthermore, according to the HPLC analysis, there was a negligible amounts of formic acid (CH2O2) and nitrous acid (HNO2) in the solution at the end of MDEA removal experiment. Eventually, the mechanism of MDEA degradation was acquired using molecular dynamics simulation (MDS), which had an acceptable coordination with the experimental results. In this way, the MDS results revealed that the presence of CH2O2 and HNO2 compounds in the products was related to the degradation of MDEA and their production as by-products during the SCWO experiments.
Collapse
Affiliation(s)
- Mohammad Noor Ghasemi
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, 7134851154, Shiraz, , Iran
| | - Feridun Esmaeilzadeh
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, 7134851154, Shiraz, , Iran.
| | - Dariush Mowla
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, 7134851154, Shiraz, , Iran
| | - Abbas Elhambakhsh
- Department of Chemical and Petroleum Engineering, School of Chemical and Petroleum Engineering, Enhanced Oil and Gas Recovery Institute, Advanced Research Group for Gas Condensate Recovery, Shiraz University, 7134851154, Shiraz, , Iran
| |
Collapse
|
20
|
Ma W, Pan J, Ren W, Chen L, Huang L, Xu S, Jiang Z. Fabrication of antibacterial and self-cleaning CuxP@g-C3N4/PVDF-CTFE mixed matrix membranes with enhanced properties for efficient ultrafiltration. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120792] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
21
|
Zhang B, Deng J, Xie J, Wu H, Wei C, Li Z, Qiu G, Wei C, Zhu S. Microbial community composition and function prediction involved in the hydrolytic bioreactor of coking wastewater treatment process. Arch Microbiol 2022; 204:426. [PMID: 35751757 DOI: 10.1007/s00203-022-03052-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 04/08/2022] [Accepted: 06/03/2022] [Indexed: 11/25/2022]
Abstract
The hydrolytic acidification process has a strong ability to conduct denitrogenation and increase the biological oxygen demand/chemical oxygen demand ratio in O/H/O coking wastewater treatment system. More than 80% of the total nitrogen (TN) was removed in the hydrolytic bioreactor, and the hydrolytic acidification process contributed to the provision of carbon sources for the subsequent nitrification process. The structure and diversity of microbial communities were elaborated using high-throughput MiSeq of the 16S rRNA genes. The results revealed that the operational taxonomic units (OTUs) belonged to phyla Bacteroidetes, Betaproteobacteria, and Alphaproteobacteria were the dominant taxa involved in the denitrogenation and degradation of refractory contaminants in the hydrolytic bioreactor, with relative abundances of 22.94 ± 3.72, 29.77 ± 2.47, and 18.23 ± 0.26%, respectively. The results of a redundancy analysis showed that the OTUs belonged to the genera Thiobacillus, Rhodoplanes, and Hylemonella in the hydrolytic bioreactor strongly positively correlated with the chemical oxygen demand, TN, and the removal of phenolics, respectively. The results of a microbial co-occurrence network analysis showed that the OTUs belonged to the phylum Bacteroidetes and the genus Rhodoplanes had a significant impact on the efficiency of removal of contaminants that contained nitrogen in the hydrolytic bioreactor. The potential function profiling results indicate the complementarity of nitrogen metabolism, methane metabolism, and sulfur metabolism sub-pathways that were considered to play a significant role in the process of denitrification. These results provide new insights into the further optimization of the performance of the hydrolytic bioreactor in coking wastewater treatment.
Collapse
Affiliation(s)
- Baoshan Zhang
- Guangdong Province Key Laboratory for Biotechnology Drug Candidates, School of Biosciences and Biopharmaceutics, Guangdong Pharmaceutical University, Guangzhou, China
| | - Jinsi Deng
- Guangdong Province Key Laboratory for Biotechnology Drug Candidates, School of Biosciences and Biopharmaceutics, Guangdong Pharmaceutical University, Guangzhou, China
| | - Junting Xie
- Guangdong Province Key Laboratory for Biotechnology Drug Candidates, School of Biosciences and Biopharmaceutics, Guangdong Pharmaceutical University, Guangzhou, China
| | - Haizhen Wu
- School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China
| | - Cong Wei
- School of Environment and Energy, South China University of Technology, Guangzhou, China
| | - Zemin Li
- School of Environment and Energy, South China University of Technology, Guangzhou, China
| | - Guanglei Qiu
- School of Environment and Energy, South China University of Technology, Guangzhou, China
| | - Chaohai Wei
- School of Environment and Energy, South China University of Technology, Guangzhou, China.
| | - Shuang Zhu
- Guangdong Province Key Laboratory for Biotechnology Drug Candidates, School of Biosciences and Biopharmaceutics, Guangdong Pharmaceutical University, Guangzhou, China.
| |
Collapse
|
22
|
Xie ZH, He CS, Zhou HY, Li LL, Liu Y, Du Y, Liu W, Mu Y, Lai B. Effects of Molecular Structure on Organic Contaminants' Degradation Efficiency and Dominant ROS in the Advanced Oxidation Process with Multiple ROS. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:8784-8795. [PMID: 35584301 DOI: 10.1021/acs.est.2c00464] [Citation(s) in RCA: 99] [Impact Index Per Article: 49.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this study, the previously overlooked effects of contaminants' molecular structure on their degradation efficiencies and dominant reactive oxygen species (ROS) in advanced oxidation processes (AOPs) are investigated with a peroxymonosulfate (PMS) activation system selected as the typical AOP system. Averagely, degradation efficiencies of 19 contaminants are discrepant in the CoCaAl-LDO/PMS system with production of SO4•-, •OH, and 1O2. Density functional theory calculations indicated that compounds with high EHOMO, low-energy gap (ΔE = ELUMO - EHOMO), and low vertical ionization potential are more vulnerable to be attacked. Further analysis disclosed that the dominant ROS was the same one when treating similar types of contaminants, namely SO4•-, 1O2, 1O2, and •OH for the degradation of CBZ-like compounds, SAs, bisphenol, and triazine compounds, respectively. This phenomenon may be caused by the contaminants' structures especially the commonly shared or basic parent structures which can affect their effective reaction time and second-order rate constants with ROS, thus influencing the contribution of each ROS during its degradation. Overall, the new insights gained in this study provide a basis for designing more effective AOPs to improve their practical application in wastewater treatment.
Collapse
Affiliation(s)
- Zhi-Hui Xie
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Chuan-Shu He
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Hong-Yu Zhou
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Ling-Li Li
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Yang Liu
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Ye Du
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Wen Liu
- College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Yang Mu
- CAS Key Laboratory of Urban Pollutant Conversion, Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei 230026, China
| | - Bo Lai
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China
- Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| |
Collapse
|
23
|
Yang SR, He CS, Xie ZH, Li LL, Xiong ZK, Zhang H, Zhou P, Jiang F, Mu Y, Lai B. Efficient activation of PAA by FeS for fast removal of pharmaceuticals: The dual role of sulfur species in regulating the reactive oxidized species. WATER RESEARCH 2022; 217:118402. [PMID: 35417819 DOI: 10.1016/j.watres.2022.118402] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 03/31/2022] [Accepted: 04/04/2022] [Indexed: 06/14/2023]
Abstract
As peracetic acid (PAA) is being increasingly used as an alternative disinfectant, efficient activation of PAA by low-cost and environmentally friendly catalysts over a wide pH range is potentially useful for simultaneous sterilization and pharmaceutical degradation in wastewater, such as hospital wastewater. In this study, peracetic acid (PAA) was successfully activated by low-cost and environmental-friendly FeS (25 mg/L) for efficient oxidative removal of three pharmaceuticals over a wide pH range (3.0∼9.0) as indicated by 80∼100% removal rate within 5 min. As expected, Fe(II) rather than sulfur species was the primary reactive site for PAA activation, while unlike the homogeneous Fe2+/PAA system with organic radicals (R-O·) and ·OH as the dominant reactive oxidized species (ROS), ·OH is the key reactive species in the FeS/PAA system. Interestingly and surprisingly, in-depth investigation revealed the dual role of sulfur species in regulating the reactive oxidized species: (1) S(-II) and its conversion product H2S (aq) played a significant role in Fe(II) regeneration with a result of accelerated PAA activation; (2) however, the R-O· generated in the initial seconds of the FeS/PAA process was supposed to be quickly consumed by sulfur species, resulting in ·OH as the dominant ROS over the whole process. The selective reaction of sulfur species with R-O· instead of ·OH was supported by the obviously lower Gibbs free energy of CH3COO· and sulfur species than ·OH, suggesting the preference of CH3COO· to react with sulfur species with electron transfer. After treatment with the FeS/PAA system, the products obtained from the three pharmaceuticals were detoxified and even facilitated the growth of E. coli probably due to the supply of numerous carbon sources by activated PAA. This study significantly advances the understanding of the reaction between PAA and sulfur-containing catalysts and suggests the practical application potential of the FeS/PAA process combined with biotreatment processes.
Collapse
Affiliation(s)
- Shu-Run Yang
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Chuan-Shu He
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China.
| | - Zhi-Hui Xie
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Ling-Li Li
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Zhao-Kun Xiong
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Heng Zhang
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Peng Zhou
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China
| | - Feng Jiang
- Guangdong Provincial Key Lab of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou, China
| | - Yang Mu
- Department of Environmental Science and Engineering, CAS Key Laboratory of Urban Pollutant Conversion, University of Science and Technology of China, Hefei 230026, China
| | - Bo Lai
- State Key Laboratory of Hydraulics and Mountain River Engineering, College of Architecture and Environment, Sichuan University, Chengdu 610065, China; Sino-German Centre for Water and Health Research, Sichuan University, Chengdu 610065, China.
| |
Collapse
|
24
|
Sundararaman S, Aravind Kumar J, Deivasigamani P, Devarajan Y. Emerging pharma residue contaminants: Occurrence, monitoring, risk and fate assessment - A challenge to water resource management. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 825:153897. [PMID: 35182637 DOI: 10.1016/j.scitotenv.2022.153897] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 01/31/2022] [Accepted: 02/11/2022] [Indexed: 06/14/2023]
Abstract
Water is one of the important gifts to mankind. In recent days the accessibility of pharmaceuticals in the environment is progressively a worldwide concern. The significant wellspring of these contaminations in water assets is drugs for human use or veterinary medications. Intermediates, active metabolites and raw materials present in water from pharmaceutical industry waste because of incomplete sewage treatment systems. Various pharmaceutical components such as analgesic/antipyretics such as Ibuprofen (57.9-104 ng/L), Diclofenac (17-129 ng/L), antibiotics such as Sulfamethoxazole (28.7-124.5 ng/L), Sulfamethazine (29.2-83.9 ng/L), Azithromycin (10-68 ng/L), psychiatric drug such as Carbamazepine (9.3-92.4 ng/L), stimulants such as caffeine greater than 55 ng/L, antidepressants, antihypertensive, contraceptives etc., are present in water resources and have been detected in mg/L to μg/L range. The synergic effects and ecotoxicological hazard assessment must be developed. Studies demonstrate that these drugs might cause morphological, metabolic and sex alterations on sea-going species, and interruption of biodegradation activities. Hazard analysis and assessments are in progress. However, the conventional effluent treatment methods are not sufficient to remove API (active pharmaceutical ingredients) from this water effectively. There is necessitate for continuous monitoring of the pharmaceutical compounds in aquatic ecosystem to save the environment and living form of lives from health hazards. This work highlights the hazards, environmental assessment and the mitigation measures of pharmaceutical pollutants.
Collapse
Affiliation(s)
- Sathish Sundararaman
- Department of Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India.
| | - J Aravind Kumar
- Department of Biomass and Energy Conversion, Saveetha School of Engineering, SIMATS, Chennai, 602105, Tamilnadu, India
| | - Prabu Deivasigamani
- Department of Chemical Engineering, Sathyabama Institute of Science and Technology, Chennai, India
| | - Yuvarajan Devarajan
- Department of Thermal Engineering, Saveetha School of Engineering, SIMATS, Chennai, Tamilnadu, 602105, India.
| |
Collapse
|
25
|
Parida VK, Sikarwar D, Majumder A, Gupta AK. An assessment of hospital wastewater and biomedical waste generation, existing legislations, risk assessment, treatment processes, and scenario during COVID-19. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 308:114609. [PMID: 35101807 PMCID: PMC8789570 DOI: 10.1016/j.jenvman.2022.114609] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 01/23/2022] [Accepted: 01/24/2022] [Indexed: 05/23/2023]
Abstract
Hospitals release significant quantities of wastewater (HWW) and biomedical waste (BMW), which hosts a wide range of contaminants that can adversely affect the environment if left untreated. The COVID-19 outbreak has further increased hospital waste generation over the past two years. In this context, a thorough literature study was carried out to reveal the negative implications of untreated hospital waste and delineate the proper ways to handle them. Conventional treatment methods can remove only 50%-70% of the emerging contaminants (ECs) present in the HWW. Still, many countries have not implemented suitable treatment methods to treat the HWW in-situ. This review presents an overview of worldwide HWW generation, regulations, and guidelines on HWW management and highlights the various treatment techniques for efficiently removing ECs from HWW. When combined with advanced oxidation processes, biological or physical treatment processes could remove around 90% of ECs. Analgesics were found to be more easily removed than antibiotics, β-blockers, and X-ray contrast media. The different environmental implications of BMW have also been highlighted. Mishandling of BMW can spread infections, deadly diseases, and hazardous waste into the environment. Hence, the different steps associated with collection to final disposal of BMW have been delineated to minimize the associated health risks. The paper circumscribes the multiple aspects of efficient hospital waste management and may be instrumental during the COVID-19 pandemic when the waste generation from all hospitals worldwide has increased significantly.
Collapse
Affiliation(s)
- Vishal Kumar Parida
- School of Environmental Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India
| | - Divyanshu Sikarwar
- Environmental Engineering Division, Department of Civil Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India
| | - Abhradeep Majumder
- School of Environmental Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India
| | - Ashok Kumar Gupta
- Environmental Engineering Division, Department of Civil Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302, India.
| |
Collapse
|
26
|
Cuprum/Carbon Co-doped Carbon Nitride with Adjustable Light Absorption and Carrier Separation for Synergistically Enhanced Photocatalytic Wastewater Purification. J Inorg Organomet Polym Mater 2022. [DOI: 10.1007/s10904-022-02303-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
27
|
Trajano GT, Vasconcelos OMSR, Pataca LCM, Mol MPG. Anionic surfactants monitoring in healthcare facilities - a case of Belo Horizonte City, Brazil. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:248. [PMID: 35246746 PMCID: PMC8896972 DOI: 10.1007/s10661-022-09877-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 02/17/2022] [Indexed: 05/02/2023]
Abstract
Surfactants are substances that when in aquatic environments can cause negative impacts. Hospital effluents carry numerous chemicals daily, including surfactants, used in sanitization and disinfection procedures. These chemicals are found in the effluents and reach water bodies due to a lack of proper removal in the wastewater treatment plants. The present study investigated data about wastewater monitored from healthcare facilities located in the city of Belo Horizonte, Brazil, focusing on anionic surfactants. The results showed 72 establishments monitoring this parameter, resulting in a median concentration of 1 mg L-1 and 2.49 mg L-1 mean value of anionic surfactants, between 2007 and 2019. It is also observed in the correlation between surfactants and oils in all healthcare establishment sizes, except for the medium-sized. Although anionic surfactants are the most used in cleaning product formulations, cationic surfactants still do not have specific legislation in the studied country that dictates a limit for discharge into sewage; consequently, they are not routinely monitored in effluents. However, these compounds are used in the formulation of routine hospital products.
Collapse
Affiliation(s)
- Graziela Torres Trajano
- Research and Development Department, Ezequiel Dias Foundation, Conde Pereira Carneiro St, 80 Belo Horizonte, Brazil
| | | | - Luiz Carlos Moutinho Pataca
- Research and Development Department, Ezequiel Dias Foundation, Conde Pereira Carneiro St, 80 Belo Horizonte, Brazil
| | - Marcos Paulo Gomes Mol
- Research and Development Department, Ezequiel Dias Foundation, Conde Pereira Carneiro St, 80 Belo Horizonte, Brazil.
| |
Collapse
|
28
|
Qiu B, Hu Y, Tang C, Chen Y, Cheng J. Degradation of diclofenac via sequential reduction-oxidation by Ru/Fe modified biocathode dual-chamber bioelectrochemical system: Performance, pathways and degradation mechanisms. CHEMOSPHERE 2022; 291:132881. [PMID: 34774907 DOI: 10.1016/j.chemosphere.2021.132881] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 10/26/2021] [Accepted: 11/10/2021] [Indexed: 06/13/2023]
Abstract
A sequential reduction-oxidation for DCF degradation was proposed by alternating anaerobic/aerobic conditions at Ru/Fe-biocathode in a dual-chamber bioelectrochemical system (BES). Results showed that Ru/Fe-electrode was successfully fabricated by in-situ electro-deposition, which was rough and uniformly distributed with Ru0 and Fe0 particles. The morphologic changing and biocompatibility were favorable to increase the surface area and enhance microbial adhesion on Ru/Fe-electrode. At an applied voltage of 0.6 V, the potential and impedance of Ru/Fe-biocathode were -0.80 V and 26 Ω, respectively, lower than that of carbon-felt-biocathode. It led to a higher DCF degradation efficiency of 93.2% under anaerobic conditions, which was superior to that of 88.0% under aerobic conditions. Using NaHCO3 as carbon source, DCF removal efficiency increased with increasing applied voltage, but decreased with increasing initial DCF concentration. Thirteen intermediates were measured, and two degradation pathways were proposed, among which sequential reduction-oxidation of DCF was the main pathway, dechlorination intermediates were first generated by [H] attacked under anaerobic conditions, further oxidized by microbes and OH attacked under aerobic conditions, achieving 69.6% of mineralization. After 4 d of reaction, microcystis aeruginosa growth inhibition rate decreased from 22.9 to 8.0%, signifying a significant reduction in biotoxicity. Bacteria (e.g. Nitrobacter, Nitrosomonas, Pseudofulvimonas, Aquamicrobium, Sulfurvermis, Lentimicrobiaceae, Anaerobineaceae, Bacteroidales, Hydrogenedensaceae, Dethiosulfatibacter and Azoarcus) for DCF degradation were enriched in Ru/Fe-biocathode. Microbes in Ru/Fe-biocathode had established defense mechanisms to acclimate to the unfriendly environment, while Ru/Fe-biocathode possessed higher nitrification and denitrification activities than carbon-felt-biocathode, and Ru/Fe-biocathode might be of aerobic and anaerobic biodegradation activities. DCF could be mineralized by the synergistic reaction between Ru/Fe and bacteria under sequential anaerobic/aerobic conditions.
Collapse
Affiliation(s)
- Bing Qiu
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China
| | - Yongyou Hu
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China.
| | - Chaoyang Tang
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China
| | - Yuancai Chen
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China
| | - Jianhua Cheng
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou, 510006, PR China
| |
Collapse
|
29
|
Reddy SN, Nanda S, Okolie JA, Dalai AK, Hicks MC, Hegde UG, Kozinski JA. Hydrothermal flames for subaquatic, terrestrial and extraterrestrial applications. JOURNAL OF HAZARDOUS MATERIALS 2022; 424:127520. [PMID: 34749231 DOI: 10.1016/j.jhazmat.2021.127520] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/27/2021] [Accepted: 10/13/2021] [Indexed: 06/13/2023]
Abstract
Hydrothermal flames are formed in supercritical water in the presence of a fuel and an oxidant (usually air or oxygen). Integrating hydrothermal flames as the heat source for supercritical water oxidation helps to minimize the reaction time (to milliseconds), improve the reaction kinetics and reduce the chances of corrosion and reactor plugging. This review outlines state-of-the-art research on hydrothermal flames including the impacts of process parameters on flame ignition. The ignition and sustainability of hydrothermal flames are dependent on several factors such as the type of fuel and its concentration, type of oxidant (air and oxygen) as well as the temperatures and flow rate of the feed and oxidant. The article describes some novel applications of hydrothermal flames for clean energy production, geothermal energy recovery, deep well spallation, wastewater treatment, degradation of recalcitrant nitrogen-containing compounds and heavy oil upgrading. Finally, the challenges and future perspectives of hydrothermal flame applications are discussed. This review also highlights some technical considerations relating to hydrothermal flames such as the choice of organic solvent and its characteristics, preheating, ignition mechanism, flame stability and propagation, advanced reactor configurations, mixing with subcritical and supercritical components, recirculation zones, cooling mechanisms, corrosion and salt precipitation.
Collapse
Affiliation(s)
- Sivamohan N Reddy
- Department of Chemical Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
| | - Sonil Nanda
- Titan Clean Energy Projects Corporation, Craik, Saskatchewan, Canada
| | - Jude A Okolie
- Department of Chemical and Biological Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Ajay K Dalai
- Department of Chemical and Biological Engineering, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
| | - Michael C Hicks
- Low-gravity Exploration Technology Branch, Glenn Research Center, National Aeronautics and Space Administration (NASA), Cleveland, Ohio, USA
| | - Uday G Hegde
- Low-gravity Exploration Technology Branch, Glenn Research Center, National Aeronautics and Space Administration (NASA), Cleveland, Ohio, USA; Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, Ohio, USA
| | - Janusz A Kozinski
- Faculty of Engineering, Lakehead University, Thunder Bay, Ontario, Canada
| |
Collapse
|
30
|
He F, Ren H, Li T, Liu S, Zhou R. Efficient decontamination of ciprofloxacin at neutral pH via visible light assisted Fenton-like process mediated by Fe(III)-GLDA complexation. CHEMOSPHERE 2022; 289:133199. [PMID: 34883122 DOI: 10.1016/j.chemosphere.2021.133199] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/24/2021] [Accepted: 12/04/2021] [Indexed: 06/13/2023]
Abstract
This work demonstrated a novel N,N-bis(carboxymethyl)glutamic acid (GLDA) modified visible (vis) light assisted Fenton-like system which could effectively removal ciprofloxacin (CIP) at neutral pH. The removal rate of CIP in the GLDA/Fe(III)/H2O2/vis system was 97.9% within 120 min and was approximately twice as high as that in the Fe(III)/H2O2/vis system. GLDA could significantly accelerate the Fe(III)/Fe(II) cycle under visible light irradiation. Radical scavenging experiments demonstrated that 74.2% of the Fe(II) in the GLDA/Fe(III)/H2O2/vis system originated from the ligand-to-metal charge transfer reaction between Fe(III) and GLDA. The hydroxyl radical was the dominant species for CIP degradation. H2O2 utilization kinetic modeling exhibited that 90.1% of H2O2 was used for CIP mineralization. The effects of experimental parameters and coexisting substances on the removal of CIP in the Fe(III)/GLDA/H2O2/vis system were investigated in detail. The intermediate products of CIP were explored via the high-performance liquid chromatography-mass spectrometry.
Collapse
Affiliation(s)
- Fangru He
- Key Laboratory of Groundwater Resources and Environment of the Ministry of Education, Jilin Provincial Key Laboratory of Water Resource and Environment, College of New Energy and Environment, Jilin University, 2519 Jiefang Road, Changchun, 130021, P. R. China
| | - Hejun Ren
- Key Laboratory of Groundwater Resources and Environment of the Ministry of Education, Jilin Provincial Key Laboratory of Water Resource and Environment, College of New Energy and Environment, Jilin University, 2519 Jiefang Road, Changchun, 130021, P. R. China.
| | - Tingting Li
- Key Laboratory of Groundwater Resources and Environment of the Ministry of Education, Jilin Provincial Key Laboratory of Water Resource and Environment, College of New Energy and Environment, Jilin University, 2519 Jiefang Road, Changchun, 130021, P. R. China
| | - Shuai Liu
- Key Laboratory of Groundwater Resources and Environment of the Ministry of Education, Jilin Provincial Key Laboratory of Water Resource and Environment, College of New Energy and Environment, Jilin University, 2519 Jiefang Road, Changchun, 130021, P. R. China
| | - Rui Zhou
- Key Laboratory of Groundwater Resources and Environment of the Ministry of Education, Jilin Provincial Key Laboratory of Water Resource and Environment, College of New Energy and Environment, Jilin University, 2519 Jiefang Road, Changchun, 130021, P. R. China.
| |
Collapse
|
31
|
Zare EN, Fallah Z, Le VT, Doan VD, Mudhoo A, Joo SW, Vasseghian Y, Tajbakhsh M, Moradi O, Sillanpää M, Varma RS. Remediation of pharmaceuticals from contaminated water by molecularly imprinted polymers: a review. ENVIRONMENTAL CHEMISTRY LETTERS 2022; 20:2629-2664. [PMID: 35431714 PMCID: PMC8999999 DOI: 10.1007/s10311-022-01439-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 03/15/2022] [Indexed: 05/03/2023]
Abstract
The release of pharmaceuticals into the environment induces adverse effects on the metabolism of humans and other living species, calling for advanced remediation methods. Conventional removal methods are often non-selective and cause secondary contamination. These issues may be partly solved by the use of recently-developped adsorbents such as molecularly imprinted polymers. Here we review the synthesis and application of molecularly imprinted polymers for removing pharmaceuticals in water. Molecularly imprinted polymers are synthesized via several multiple-step polymerization methods. Molecularly imprinted polymers are potent adsorbents at the laboratory scale, yet their efficiency is limited by template leakage and polymer quality. Adsorption performance of multi-templated molecularly imprinted polymers depends on the design of wastewater treatment plants, pharmaceutical consumption patterns and the population serviced by these wastewater treatment plants.
Collapse
Affiliation(s)
| | - Zari Fallah
- Faculty of Chemistry, University of Mazandaran, 47416-95447 Babolsar, Iran
| | - Van Thuan Le
- Center for Advanced Chemistry, Institute of Research and Development, Duy Tan University, 03 Quang Trung, Da Nang, 55000 Vietnam
- The Faculty of Natural Sciences, Duy Tan University, 03 Quang Trung, Da Nang, 55000 Vietnam
| | - Van-Dat Doan
- Faculty of Chemical Engineering, Industrial University of Ho Chi Minh City, 12 Nguyen Van Bao, Ho Chi Minh, 70000 Vietnam
| | - Ackmez Mudhoo
- Department of Chemical and Environmental Engineering, Faculty of Engineering, University of Mauritius, Réduit, 80837 Mauritius
| | - Sang-Woo Joo
- Department of Chemistry, Soongsil University, Seoul, 06978 South Korea
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978 South Korea
| | - Mahmood Tajbakhsh
- Faculty of Chemistry, University of Mazandaran, 47416-95447 Babolsar, Iran
| | - Omid Moradi
- Department of Chemistry, Shahr-e-Qods Branch, Islamic Azad University, Tehran, Iran
| | - Mika Sillanpää
- Department of Chemical Engineering, School of Mining, Metallurgy and Chemical Engineering, University of Johannesburg, P. O. Box 17011, Doornfontein, 2028 South Africa
| | - Rajender S. Varma
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute, Palacký University in Olomouc, Šlechtitelů 27, 783 71 Olomouc, Czech Republic
| |
Collapse
|
32
|
Sangkham S. A review on detection of SARS-CoV-2 RNA in wastewater in light of the current knowledge of treatment process for removal of viral fragments. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 299:113563. [PMID: 34488114 PMCID: PMC8373619 DOI: 10.1016/j.jenvman.2021.113563] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 08/02/2021] [Accepted: 08/17/2021] [Indexed: 05/05/2023]
Abstract
The entire globe is affected by the novel disease of coronavirus 2019 (COVID-19 or 2019-nCoV), which is formally recognised as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The World Health Organisation (WHO) announced this disease as a global pandemic. The presence of SARS-CoV-2 RNA in unprocessed wastewater has become a cause of worry due to these emerging pathogens in the process of wastewater treatment, as reported in the present study. This analysis intends to interpret the fate, environmental factors and route of transmission of SARS-CoV-2, along with its eradication by treating the wastewater for controlling and preventing its further spread. Different recovery estimations of the virus have been depicted by the detection of SARS-CoV-2 RNA in wastewater through the viral concentration techniques. Most frequently used viral concentration techniques include polyethylene glycol (PEG) precipitation, ultrafiltration, electronegative membrane, and ultracentrifugation, after which the detection and quantification of SARS-CoV-2 RNA are done in wastewater samples through quantitative reverse transcription-polymerase chain reaction (RT-qPCR). The wastewater treatment plant (WWTP) holds the key responsibility of eliminating pathogens prior to the discharge of wastewater into surface water bodies. The removal of SARS-CoV-2 RNA at the treatment stage is dependent on the operations of wastewater treatment systems during the outbreak of the virus; particularly, in the urban and extensively populated regions. Efficient primary, secondary and tertiary methods of wastewater treatment and disinfection can reduce or inactivate SARS-CoV-2 RNA before being drained out. Nonetheless, further studies regarding COVID-19-related disinfectants, environment conditions and viral concentrations in each treatment procedure, implications on the environment and regular monitoring of transmission need to be done urgently. Hence, monitoring the SARS-CoV-2 RNA in samples of wastewater under the procedure of wastewater-based epidemiology (WBE) supplement the real-time data pertaining to the investigation of the COVID-19 pandemic in the community, regional and national levels.
Collapse
Affiliation(s)
- Sarawut Sangkham
- Department of Environmental Health, School of Public Health, University of Phayao, Muang District, Phayao, 56000, Thailand.
| |
Collapse
|
33
|
Qiu B, Hu Y, Tang C, Chen Y, Cheng J. Simultaneous mineralization of 2-anilinophenylacetate and denitrification by Ru/Fe modified biocathode double-chamber microbial fuel cell. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 792:148446. [PMID: 34465036 DOI: 10.1016/j.scitotenv.2021.148446] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 05/21/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
A double-chamber microbial fuel cell (MFC) with Ru/Fe-modified-biocathode was constructed for simultaneous mineralization of 2-anilinophenylacetate (APA) and denitrification. The factors on performance of simultaneous APA degradation and denitrification were explored. The contributions of ROS to APA degradation were evaluated by EPR and quenching experiments. The microbial community of Ru/Fe-modified-biocathode was determined by high-throughput sequencing. Results showed that low resistance accelerated APA degradation by Ru/Fe-modified-biocathode, while higher initial APA concentration inhibited microbial activity of the biocathode. The optimum ammonia concentration was 50 mg L-1, while too high or too low ammonia concentration did not favor APA degradation. The APA degradation efficiency of Ru/Fe-modified-biocathode-MFC was higher than that of other modified-cathode-MFCs. The APA degradation process confirmed to the pseudo-first-order kinetic model, and APA degradation kinetic constant, the maximum removal efficiency of TOC, ammonia and TN were 2.15d-1, 59.70%, 99.20% and 44.56% respectively, signifying a simultaneous APA mineralization and denitrification performance of Ru/Fe-modified-biocathode-MFC. The coulombic efficiency decreased with APA concentration increase. OH was the primary radical in APA degradation progress. Eight kinds of intermediates were measured, and two APA degradation pathways were proposed, among which APA hydroxylation was the main pathway. The microbial community of Ru/Fe-modified-biocathode was dominated with Nitrosomonas at genus level, and enriched with various APA-degraders, nitrifiers, and denitrifiers such as Pseudomonas, Nitrospira, Nitrobacter, Paracoccus, Thermomonas, Dechloromonas, and Clostridium_Sutra_stricto_1. COG analysis showed the redox reaction of Ru/Fe might affect signal transduction and environment adaptation, while FAPROTAX analysis suggested that Ru/Fe-modified-biocathode exhibited higher nitrification activity than that of carbon-felt-biocathode. The synergistic mechanism of simultaneous APA mineralization and denitrification was mainly redox reaction of Ru/Fe and supplemented by aerobic biodegradation.
Collapse
Affiliation(s)
- Bing Qiu
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| | - Yongyou Hu
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China.
| | - Chaoyang Tang
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| | - Yuancai Chen
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| | - Jianhua Cheng
- School of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China; The Key Lab of Pollution Control and Ecosystem Restoration in Industry Clusters, Ministry of Education, South China University of Technology, Guangzhou Higher Education Mega Centre, Guangzhou 510006, China
| |
Collapse
|
34
|
Zare EN, Iftekhar S, Park Y, Joseph J, Srivastava V, Khan MA, Makvandi P, Sillanpaa M, Varma RS. An overview on non-spherical semiconductors for heterogeneous photocatalytic degradation of organic water contaminants. CHEMOSPHERE 2021; 280:130907. [PMID: 34162104 DOI: 10.1016/j.chemosphere.2021.130907] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 05/01/2021] [Accepted: 05/12/2021] [Indexed: 06/13/2023]
Abstract
Because of their carcinogenicity and mutagenicity, the elimination of organic contaminants from surface and subsurface water is a subject of environmental significance. Conventional water decontamination approaches such as membrane separation, ultrafiltration, adsorption, reverse osmosis, coagulation, etc., have relatively higher operating costs and can generate highly toxic secondary contaminants. On the other hand, heterogeneous photocatalysis, an advanced oxidation process (AOP), is considered a clean and cost-effective process for organic pollutants degradation. Owing to their distinctive structure and physicochemical properties non-spherical semiconductors have gained considerable limelight in the photocatalytic degradation of organic contaminants. The current review briefly introduces a wide range of organic water contaminants. Recent advances in non-spherical semiconductor assembly and their photocatalytic degradation applications are highlighted. The underlying mechanism, fundamentals of photocatalytic reactions, and the factors affecting the degradation performance are also alluded including the current challenges and future research perspectives.
Collapse
Affiliation(s)
| | - Sidra Iftekhar
- Department of Applied Physics, University of Eastern Finland, Kuopio, 70210, Finland
| | - Yuri Park
- Department of Separation Science, Lappeenranta-Lahti University of Technology LUT, Sammonkatu 12, FI, 50130, Mikkeli, Finland
| | - Jessy Joseph
- Department of Separation Science, Lappeenranta-Lahti University of Technology LUT, Sammonkatu 12, FI, 50130, Mikkeli, Finland
| | - Varsha Srivastava
- Department of Separation Science, Lappeenranta-Lahti University of Technology LUT, Sammonkatu 12, FI, 50130, Mikkeli, Finland
| | - Moonis Ali Khan
- Chemistry Department, College of Science, King Saud University, Riyadh, 11451, Saudi Arabia
| | - Pooyan Makvandi
- Center for Materials Interfaces, Istituto Italiano di Tecnologia (IIT), Viale R. Piaggio 34, 56025, Pontedera, Pisa, Italy
| | - Mika Sillanpaa
- Environmental Engineering and Management Research Group, Ton Duc Thang University, Ho Chi Minh City, Viet Nam; Faculty of Environment and Labour Safety, Ton Duc Thang University, Ho Chi Minh City, Vietnam.
| | - Rajender S Varma
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute, Palacký University in Olomouc, Šlechtitelů 27, 783 71, Olomouc, Czech Republic.
| |
Collapse
|
35
|
Hube S, Wu B. Mitigation of emerging pollutants and pathogens in decentralized wastewater treatment processes: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 779:146545. [PMID: 33752021 DOI: 10.1016/j.scitotenv.2021.146545] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 03/09/2021] [Accepted: 03/13/2021] [Indexed: 06/12/2023]
Abstract
Emerging pollutants (such as micropollutants, microplastics) and pathogens present in wastewater are of rising concern because their release can affect the natural environment and drinking water resources. In this decade, with increasing numbers of small-scale decentralized wastewater systems globally, the status of emerging pollutant and pathogen mitigation in the decentralized wastewater treatment processes has received more attention. This state-of-the-art review aims to discuss the mitigation efficiencies and mechanisms of micropollutants, microplastics, and pathogens in single-stage and hybrid decentralized wastewater treatment processes. The reviewed results revealed that hybrid wastewater treatment facilities could display better performance compared to stand-alone facilities. This is because the multiple treatment steps could offer various microenvironments, allowing incorporating several mitigation mechanisms (such as sorption, degradation, filtration, etc.) to remove complicated emerging pollutants and pathogens. The factors (such as system operation conditions, environmental conditions, wastewater matrix) influencing the removals of emerging pollutants from wastewater in these systems have been further identified. Nevertheless, it was found that very limited research work focused on synergised or conflicted effects of operation conditions on various emerging pollutants naturally present in the wastewater. Meanwhile, effective, reliable, and rapid analysis of the emerging pollutants and pathogens in the complicated wastewater matrix is still a major challenge.
Collapse
Affiliation(s)
- Selina Hube
- Faculty of Civil and Environmental Engineering, University of Iceland, Hjardarhagi 2-6, IS-107 Reykjavik, Iceland
| | - Bing Wu
- Faculty of Civil and Environmental Engineering, University of Iceland, Hjardarhagi 2-6, IS-107 Reykjavik, Iceland.
| |
Collapse
|
36
|
Javaid R, Qazi UY, Ikhlaq A, Zahid M, Alazmi A. Subcritical and supercritical water oxidation for dye decomposition. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 290:112605. [PMID: 33894487 DOI: 10.1016/j.jenvman.2021.112605] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/26/2021] [Accepted: 04/10/2021] [Indexed: 06/12/2023]
Abstract
The total annual output of synthetic dyes exceeds 7 × 105 tons. About 1,000 tons of non-biodegradable synthetic dyes are released every year into the natural streams and water sources from textile wastes. The release of these colored wastewater exerts negative impact on aquatic ecology and human beings because of the poisonous and carcinogenic repercussions of dyes involved in coloration production. Therefore, with a growing interest in the environment, efficient technologies need to be developed to eliminate dyes from local and industrial wastewater. Supercritical water oxidation as a promising wastewater treatment technology has many advantages, such as a rapid reaction and pollution-free products. However, due to corrosion, salt precipitation and operational problems, supercritical water oxidation process did not gain expected industrial development. These technical difficulties can be overcome by application of non-corrosive subcritical water as a reaction medium. This work summarizes the negative impacts of dyes and role of subcritical and supercritical water and their efficiencies in dye oxidation processes.
Collapse
Affiliation(s)
- Rahat Javaid
- Renewable Energy Research Center, Fukushima Renewable Energy Institute, National Institute of Advanced Industrial Science and Technology, AIST, 2-2-9 Machiikedai, Koriyama, Fukushima, 963-0298, Japan.
| | - Umair Yaqub Qazi
- Department of Chemistry, College of Science, University of Hafr Al Batin, P.O Box 1803, Hafr Al Batin, 39524, Saudi Arabia; Division of Nanomaterials and Chemistry, Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui, 230026, PR China.
| | - Amir Ikhlaq
- Institute of Environmental Engineering and Research, University of Engineering and Technology, GT Road, 54890, Lahore, Punjab, Pakistan
| | - Muhammad Zahid
- Department of Chemistry, University of Agriculture Faisalabad, Pakistan
| | - Amira Alazmi
- Department of Chemistry, University Colleges at Nairiyah, University of Hafr Al Batin. P.O Box 1803 Hafr Al Batin 39524, Kingdom of Saudi Arabia
| |
Collapse
|
37
|
Achak M, Alaoui Bakri S, Chhiti Y, M'hamdi Alaoui FE, Barka N, Boumya W. SARS-CoV-2 in hospital wastewater during outbreak of COVID-19: A review on detection, survival and disinfection technologies. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 761:143192. [PMID: 33153744 PMCID: PMC7585361 DOI: 10.1016/j.scitotenv.2020.143192] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 10/18/2020] [Indexed: 05/17/2023]
Abstract
Currently, the apparition of new SARS-CoV, known as SARS-CoV-2, affected more than 34 million people and causing high death rates worldwide. Recently, several studies reported SARS-CoV-2 ribonucleic acid (RNA) in hospital wastewater. SARS-CoV-2 can be transmitted between humans via respiratory droplets, close contact and fomites. Fecal-oral transmission is considered also as a potential route of transmission since several scientists confirmed the presence of SARS-CoV-2 RNA in feces of infected patients, therefore its transmission via feces in aquatic environment, particularly hospital wastewater. Hospitals are one of the important classes of polluting sectors around the world. It was identified that hospital wastewater contains hazardous elements and a wide variety of microbial pathogens and viruses. Therefore, this may potentially pose a significant risk of public health and environment infection. This study reported an introduction about the Physical-chemical and microbiological characterization of hospital wastewater, which can be a route to identify potential technology to reduce the impact of hospital contaminants before evacuation. The presence of SARS-CoV-2 in aqueous environment was reviewed. The knowledge of the detection and survival of SARS-CoV-2 in wastewater and hospital wastewater were described to understand the different routes of SARS-CoV-2 transmission, which is also useful to avoid the outbreak of CoV-19. In addition, disinfection technologies used commonly for deactivation of SARS-CoV-2 were highlighted. It was revealed that, chlorine-containing disinfectants are the most commonly used disinfectants in this field of research. Meanwhile, other efficient technologies must be developed and improved to avoid another wave of the pandemic of COVID-19 infections.
Collapse
Affiliation(s)
- Mounia Achak
- Science Engineer Laboratory for Energy, National School of Applied Sciences, Chouaïb Doukkali University, El Jadida, Morocco; Chemical & Biochemical Sciences, Green Process Engineering, CBS, Mohammed VI Polytechnic University, Ben Guerir, Morocco.
| | - Soufiane Alaoui Bakri
- Science Engineer Laboratory for Energy, National School of Applied Sciences, Chouaïb Doukkali University, El Jadida, Morocco
| | - Younes Chhiti
- Advanced Materials and Process Engineering Laboratory, National School of Chemistry, Ibn Tofail University, Kenitra, Morocco; Mohamed VI Polytechnic University, Ben Guerir, Morocco
| | - Fatima Ezzahrae M'hamdi Alaoui
- Science Engineer Laboratory for Energy, National School of Applied Sciences, Chouaïb Doukkali University, El Jadida, Morocco
| | - Noureddine Barka
- Sultan Moulay Slimane University of Beni Mellal, Research Group in Environmental Sciences and Applied Materials (SEMA), FP Khouribga, Khouribga, Morocco
| | - Wafaa Boumya
- Science Engineer Laboratory for Energy, National School of Applied Sciences, Chouaïb Doukkali University, El Jadida, Morocco; Sultan Moulay Slimane University of Beni Mellal, Research Group in Environmental Sciences and Applied Materials (SEMA), FP Khouribga, Khouribga, Morocco
| |
Collapse
|