1
|
Kim HL, Park SM, Cho IJ, Kim YM, Kim DH, Kim SH, Kim KI, Sung KC, Ihm SH, Shin J, Kim Y, Oh K, Lee EM. Standardized protocol of blood pressure measurement and quality control program for the Korea National Health and Nutrition Examination Survey. Clin Hypertens 2023; 29:28. [PMID: 37821979 PMCID: PMC10568909 DOI: 10.1186/s40885-023-00252-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 09/05/2023] [Indexed: 10/13/2023] Open
Abstract
Accurate blood pressure (BP) measurement is crucial for hypertension detection and management. The Korea National Health and Nutrition Examination Survey (KNHANES) assesses the health of Koreans using representative cross-sectional data. BP measurements were historically done with mercury sphygmomanometers for participants aged ≥10 years. However, KNHANES transitioned to Greenlight 300TM (mercury-free auscultatory device) in 2020 for participants aged ≥6 years and used dual devices (Microlife WatchBP Office AFIB and Greenlight) in 2021-2022. To ensure consistency, KNHANES will adopt Microlife as the unified BP device with Greenlight for device validation from 2023. Under the new protocol, participants aged ≥6 years will have their BP measured three times at 30-second intervals after a 5-minute rest under ambient temperature (20-25℃) and noise ≤65 dB. The average of the 2nd and 3rd readings will be used as the representative BP value. The quality control (QC) program involves four trained examiners passing the "quality control and assurance of BP measurement program" three times annually, and undergoing "video monitoring of weekly calibration process" once a year. Additionally, the QC team will conduct "on-site evaluations of BP measurement" at mobile examination centers three times a year. A Five-Step QC process for BP devices was also developed. This document outlines the standardized BP measurement protocol and rigorous QC program in KNHANES, aiming to ensure accurate and reliable BP data for epidemiological research and public health policymaking in South Korea.
Collapse
Affiliation(s)
- Hack-Lyoung Kim
- Division of Cardiology, Department of Internal Medicine, Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Sang Min Park
- Divison of Cardiology, Department of Internal Medicine, Nowon Eulji Medical Center, Eulji University College of Medicine, Seoul, Republic of Korea
| | - In Jeong Cho
- Division of Cardiology, Department of Internal Medicine, Ewha Womans University Seoul Hospital, Ewha Womans University College of Medicine, Seoul, Republic of Korea
| | - Yu-Mi Kim
- Department of Preventive, College of Medicine, Hanyang University, Seoul, Republic of Korea
- Hanyang University School of Public Health, Seoul, Republic of Korea
| | - Dae-Hee Kim
- Division of Cardiology, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Sung Hye Kim
- Department of Pediatrics, CHA Bundang Medical Center, CHA University, Seongnam, Republic of Korea
| | - Kwang-Il Kim
- Division of Geriatrics, Department of Internal Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea
| | - Ki-Chul Sung
- Division of Cardiology, Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Sang-Hyun Ihm
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Bucheon St. Mary's Hospital, The Catholic University of Korea, Bucheon, Republic of Korea
| | - Jinho Shin
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul, Republic of Korea
| | - Yoonjung Kim
- Division of Health and Nutrition Survey and Analysis, Bureau of Chronic Disease Prevention and Control, Korea Disease Control and Prevention Agency, Cheongju, Republic of Korea
| | - Kyungwon Oh
- Division of Health and Nutrition Survey and Analysis, Bureau of Chronic Disease Prevention and Control, Korea Disease Control and Prevention Agency, Cheongju, Republic of Korea
| | - Eun Mi Lee
- Division of Cardiology, Department of Internal Medicine, Wonkwang University Sanbon Hospital, Gunpo, Gyeonggi-do, 15865, Republic of Korea.
| |
Collapse
|
2
|
Ishigami J, Charleston J, Miller ER, Matsushita K, Appel LJ, Brady TM. Effects of Cuff Size on the Accuracy of Blood Pressure Readings: The Cuff(SZ) Randomized Crossover Trial. JAMA Intern Med 2023; 183:1061-1068. [PMID: 37548984 PMCID: PMC10407761 DOI: 10.1001/jamainternmed.2023.3264] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 05/07/2023] [Indexed: 08/08/2023]
Abstract
Importance Clinical practice guidelines recommend selecting an appropriately sized cuff based on mid-arm circumference prior to measuring blood pressure (BP). To our knowledge, the effect of miscuffing on BP measurement when using an automated BP device has not been quantified. Objective To determine the effect of using a regular BP cuff vs an appropriately sized BP cuff on automated BP readings. Design, Setting, and Participants This randomized crossover trial of community-dwelling adults with a wide range of mid-arm circumferences took place between March 16 and October 25, 2021, in Baltimore, Maryland. Participants were recruited via BP screening events at a public food market and a senior housing facility, targeted mailings to prior research participants, placement of study brochures in hypertension clinics at Johns Hopkins University, and referrals from physicians providing hypertension care to adults. Interventions Participants underwent 4 sets of triplicate BP measurements, with the initial 3 sets using an appropriate, too-small, or too-large BP cuff in random order; the fourth set of triplicate measurements was always completed with an appropriate BP cuff. Main Outcomes and Measures The primary outcome was the difference in mean BP when measured with a regular BP cuff compared with an appropriate BP cuff. The secondary outcome was the difference in BP when using too-small or too-large BP cuffs vs an appropriate BP cuff across all cuff sizes. Results were also stratified by systolic BP (≥130 mm Hg vs <130 mm Hg) and body mass index (calculated as weight in kilograms divided by height in meters squared; ≥30 vs <30). Results A total of 195 adults (mean [SD] age, 54 [16] years; 67 [34%] male; 132 [68%] Black; 100 [51%] with hypertension) were randomized for inclusion. Among individuals requiring a small BP cuff, use of a regular BP cuff resulted in a statistically significant lower BP reading (mean systolic BP difference, -3.6 [95% CI, -5.6 to -1.7] mm Hg). In contrast, among individuals requiring a large or extra-large BP cuff, use of a regular BP cuff resulted in a statistically significant higher BP reading (mean systolic BP difference, 4.8 [95% CI, 3.0-6.6] mm Hg and 19.5 [95% CI, 16.1-22.9] mm Hg, respectively). For the secondary outcome, BP differences with overcuffing and undercuffing by 1 and 2 cuff sizes were greater among those requiring larger BP cuffs. The results were consistent in stratified analyses by systolic BP and body mass index. Conclusions and Relevance In this randomized crossover trial, miscuffing resulted in strikingly inaccurate BP measurements. This is particularly concerning for settings where 1 regular BP cuff size is routinely used in all individuals, regardless of arm size. A renewed emphasis on individualized BP cuff selection is warranted. Trial Registration ClinicalTrials.gov Identifier: NCT04610775.
Collapse
Affiliation(s)
- Junichi Ishigami
- Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Jeanne Charleston
- Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Edgar R. Miller
- Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Kunihiro Matsushita
- Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Lawrence J. Appel
- Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Tammy M. Brady
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| |
Collapse
|
3
|
Shahi S, Jackson SL, Streeter TE, He S, Wall HK. Cuff Size Variation Across Manufacturers of Home Blood Pressure Devices: A Current Patient Dilemma. Am J Hypertens 2023; 36:532-535. [PMID: 37422909 DOI: 10.1093/ajh/hpad060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Accepted: 07/06/2023] [Indexed: 07/11/2023] Open
Abstract
BACKGROUND The American Heart Association (AHA) recommends cuff sizes of blood pressure (BP) monitoring devices based on patient arm circumference, which is critical for accurate BP measurement. This study aimed to assess cuff size variation across validated BP devices and to examine the degree of alignment with the AHA recommendations. METHODS Data on home BP devices were obtained from the US BP Validated Device Listing website and listed cuff sizes were compared against AHA recommendations: small adult (22-26 cm), adult (27-34 cm), large (35-44 cm), and extra-large (XL) (45-52 cm). RESULTS There were 42 home validated BP devices from 13 manufacturers, and none offered cuffs that were aligned with the AHA recommendations. Over half of the devices (22, 52.4%) were compatible with only a broad-range cuff, generally excluding arm sizes larger than 44 cm. Only 5 devices from 4 manufacturers offered a cuff labeled "XL," and of these, only 3 devices had sizes that covered the AHA XL range. Terminology lacked consistency with manufacturers using: different labels to describe the same-sized cuffs (e.g., 22-42 cm was labeled "integrated," "standard," "adult," "large," and "wide range"); the same labels to describe differently sized cuffs (e.g., cuffs labeled "large" were sized 22-42 cm, 32-38 cm, 32-42 cm, 36-45 cm). CONCLUSIONS Manufacturers of US home BP devices employ inconsistent terminologies and thresholds for cuff sizes, and sizes were not aligned with AHA recommendations. This lack of standardization could pose challenges for clinicians and patients attempting to select a properly sized cuff to support hypertension diagnosis and management.
Collapse
Affiliation(s)
- Shamim Shahi
- Division for Heart Disease and Stroke Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Sandra L Jackson
- Division for Heart Disease and Stroke Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Taylor E Streeter
- Division for Heart Disease and Stroke Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Siran He
- Division for Heart Disease and Stroke Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Hilary K Wall
- Division for Heart Disease and Stroke Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| |
Collapse
|
4
|
Mavragani A, Wang J, Chung ML, Sharma K. Examining the Individual Response to a Low-Sodium Diet in Patients with Hypertension: Protocol for a Pilot Randomized Controlled Trial. JMIR Res Protoc 2023; 12:e39058. [PMID: 36780210 PMCID: PMC9972206 DOI: 10.2196/39058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 12/13/2022] [Accepted: 01/03/2023] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Excessive dietary sodium intake is an independent risk factor for hypertension and cardiovascular disease (CVD). Despite the large body of evidence concerning the effects of dietary interventions on blood pressure (BP) and CVD outcomes, trials have often reported low adherence to decreased sodium intake, likely due in part to heterogeneous BP responses. To address the challenges, recent clinical findings suggested a precise and personalized dietary approach that seeks to deliver more preventive and practical dietary advice than the "one-size-fits-all" guidelines and weighs the personal risk of developing specific diseases. OBJECTIVE The purpose of this pilot randomized controlled trial was to test the feasibility and preliminary efficacy of integrating the use of mobile technology and metabolomics with a low-sodium diet intervention in patients with hypertension to develop personalized low-sodium diet programs. Additionally, the study will examine the associations of urine metabolites with urinary sodium levels and BP control based on the hypothesis that targeted urine metabolites. In this report, we describe the design and protocol of the pilot trial. METHODS A total of 40 patients with hypertension will be randomly assigned to either a 8-week low-sodium diet group (n=20) or a standard care group (n=20). Each week, intervention participants went through individual sessions with an interventionist via videoconferencing to discuss low-sodium diet regimens, patients' food choices, and BP tracks on mobile apps. The control group followed their usual care for hypertension management. All participants in both groups monitored diet and BP using mobile apps for 8 weeks. A 24-hour urinary sodium excretion for the estimation of dietary sodium intake, systolic, and diastolic BPs were measured at the baseline and at 8 weeks. The primary outcomes of this study include the feasibility of conducting a randomized controlled trial (RCT) by reporting recruitment, retention, and completion statistics. The preliminary effects of intervention will be tested by a generalized estimating equation model. RESULTS This pilot RCT study was approved by the institutional review board at the University of Texas Health San Antonio in January 2021. The first participant was enrolled in April 2021, and currently, 26 participants were enrolled. All data collection is expected to conclude by March 2023, with data analysis and study results ready for reporting by December 2023. Findings from this pilot RCT will further guide the team in planning a future large-scale study. CONCLUSIONS The findings of this proposed study will establish a comprehensive knowledge base for future research and development of personalized dietary interventions to promote adherence to dietary strategies and self-management of chronic disease using the Precision Health approach for millions of Americans who are struggling with uncontrolled hypertension. TRIAL REGISTRATION ClinicalTrials.gov NCT04764253; https://clinicaltrials.gov/ct2/show/NCT04764253. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) DERR1-10.2196/39058.
Collapse
Affiliation(s)
| | - Jing Wang
- College of Nursing, Florida State University, Tallahassee, FL, United States
| | - Misook L Chung
- College of Nursing, University of Kentucky, Lexington, KY, United States
| | - Kumar Sharma
- Department of Medicine, University of Texas Health San Antonio, San Antonio, TX, United States
| |
Collapse
|
5
|
Hansen J, Pohlmann M, Beckmann JH, Klose P, Gruenewald M, Renner J, Lorenzen U, Elke G. Comparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery – a secondary analysis of a prospective observational study. BMC Anesthesiol 2022; 22:83. [PMID: 35346046 PMCID: PMC8962134 DOI: 10.1186/s12871-022-01619-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 03/17/2022] [Indexed: 11/18/2022] Open
Abstract
Background Oscillometric, non-invasive blood pressure measurement (NIBP) is the first choice of blood pressure monitoring in the majority of low and moderate risk surgeries. In patients with morbid obesity, however, it is subject to several limitations. The aim was to compare arterial pressure monitoring by NIBP and a non-invasive finger-cuff technology (Nexfin®) with the gold-standard invasive arterial pressure (IAP). Methods In this secondary analysis of a prospective observational, single centre cohort study, systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) were measured at 16 defined perioperative time points including posture changes, fluid bolus administration and pneumoperitoneum (PP) in patients undergoing laparoscopic bariatric surgery. Absolute arterial pressures by NIBP, Nexfin® and IAP were compared using correlation and Bland Altman analyses. Interchangeability was defined by a mean difference ≤ 5 mmHg (SD ≤8 mmHg). Percentage error (PE) was calculated as an additional statistical estimate. For hemodynamic trending, concordance rates were analysed according to the Critchley criterion. Results Sixty patients (mean body mass index of 49.2 kg/m2) were enrolled and data from 56 finally analysed. Pooled blood pressure values of all time points showed a significant positive correlation for both NIPB and Nexfin® versus IAP. Pooled PE for NIBP versus IAP was 37% (SAP), 35% (DAP) and 30% (MAP), for Nexfin versus IAP 23% (SAP), 26% (DAP) and 22% (MAP). Correlation of MAP was best and PE lowest before induction of anesthesia for NIBP versus IAP (r = 0.72; PE 24%) and after intraoperative fluid bolus administration for Nexfin® versus IAP (r = 0.88; PE: 17.2%). Concordance of MAP trending was 90% (SAP 85%, DAP 89%) for NIBP and 91% (SAP 90%, DAP 86%) for Nexfin®. MAP trending was best during intraoperative ATP positioning for NIBP (97%) and at induction of anesthesia for Nexfin® (97%). Conclusion As compared with IAP, interchangeability of absolute pressure values could neither be shown for NIBP nor Nexfin®, however, NIBP showed poorer overall correlation and precision. Overall trending ability was generally high with Nexfin® surpassing NIBP. Nexfin® may likely render individualized decision-making in the management of different hemodynamic stresses during laparoscopic bariatric surgery, particularly where NIBP cannot be reliably established. Trial registration The non-interventional, observational study was registered retrospectively at (NCT03184285) on June 12, 2017.
Collapse
|
6
|
Olerich K, Soper D, Delaney S, Sterrett M. Pregnancy Care for Patients With Super Morbid Obesity. Front Pediatr 2022; 10:839377. [PMID: 35928678 PMCID: PMC9343711 DOI: 10.3389/fped.2022.839377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 06/22/2022] [Indexed: 11/13/2022] Open
Abstract
The patient with obesity represents unique challenges to the medical community and, in the setting of pregnancy, additional risks to both mother and fetus. This document will focus on the risks and considerations needed to care for the women with obesity and her fetus during the antepartum, intrapartum, and immediate postpartum stages of pregnancy. Specific attention will be given to pregnancy in the setting of class III and super morbid obesity.
Collapse
Affiliation(s)
- Kelsey Olerich
- Department of Obstetrics and Gynecology, University of Washington, Seattle, WA, United States
| | - David Soper
- Department of Obstetrics and Gynecology, Medical University of South Carolina, Charleston, SC, United States
| | - Shani Delaney
- Department of Obstetrics and Gynecology, University of Washington, Seattle, WA, United States
| | - Mary Sterrett
- Department of Obstetrics and Gynecology, University of Washington, Seattle, WA, United States.,Department of Obstetrics and Gynecology, Medical University of South Carolina, Charleston, SC, United States
| |
Collapse
|
7
|
Innovation in measuring obese patients' blood pressure: measurement with conical wrapping technique. Blood Press Monit 2021; 27:63-69. [PMID: 34417375 DOI: 10.1097/mbp.0000000000000565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Accurate measurement of blood pressure (BP) is difficult in obese patients due to their upper arm shape and width. Errors made during BP measurement cause misdiagnosis or lead to wrong treatment. METHOD The data of this methodological study were collected from 40 patients who were 18 years old or above, with a BMI above 25 kg/m2, and who were followed up with radial catheter arterial pressure in adult intensive care and postoperative care units between March and December 2020. RESULTS In total 55% of the participants were male with a mean age of 63.9 years, mean height of 165.7 cm, mean weight of 85.2 kg and mean BMI of 31.0 ± 2.1 kg/m2. Intra-arterial BP (IABP) measurement values were found to be correlated with conical wrapping technique and cylindrical wrapping technique (P < 0.001). As a result, a statistically significance was found between conical SBP and intra-arterial SBP (r = 0.921; P < 0.05) and conical DBP and intra-arterial DBP (r = 0.902; P < 0.05). CONCLUSION It was determined that the SBP and DBP results of the conical wrapping technique were closer to the results obtained by IABP measurements. For this reason, it is more appropriate to measure BP with conical wrapping technique in clinically obese patients.
Collapse
|
8
|
Patient preferences for ambulatory blood pressure monitoring devices: Wrist-type or arm-type? PLoS One 2021; 16:e0255871. [PMID: 34370782 PMCID: PMC8352047 DOI: 10.1371/journal.pone.0255871] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Accepted: 07/26/2021] [Indexed: 11/29/2022] Open
Abstract
Background Ambulatory blood pressure monitoring (ABPM) is important in evaluating average 24-hour blood pressure (BP) levels, circadian rhythm, sleeping BP and BP variability but many patients are reluctant to use standard ABPM devices. Methods We compared two validated ABPM devices, the BPro tonometric wrist monitor and the A&D TM-2430 oscillometric upper arm monitor, for agreement of recordings and acceptability in 37 hypertensive patients (aged 55±9 years). Results Successful BP measurements were less frequent with the wrist-type than the arm-type device during the sleeping (66.3% vs. 92.9%, P <0.01) and awake periods (56.2% vs. 86.5%, P <0.01). Comparable paired readings showed no significant difference in systolic BP but diastolic BP (DBP) values were higher with the wrist compared to the arm monitor (24-hour 89±13 vs. 85±14 mmHg, P <0.01) with similar differences awake and sleeping. Bland-Altman analysis showed some large discrepancies between individual arm and wrist monitor measurements. More patients found the wrist monitor more comfortable to use than the arm monitor. Conclusions Despite the difference in individual BP measurements and the systematic overestimation of DBP values with the BPro device, wrist monitors with good patient acceptability may be useful to facilitate ABPM in some patients to provide additional information about cardiovascular risk and response to antihypertensive therapies.
Collapse
|
9
|
Awad H, Alcodray G, Raza A, Boulos R, Essandoh M, Bhandary S, Dalton R. Intraoperative Hypotension-Physiologic Basis and Future Directions. J Cardiothorac Vasc Anesth 2021; 36:2154-2163. [PMID: 34218998 DOI: 10.1053/j.jvca.2021.05.057] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 05/26/2021] [Accepted: 05/30/2021] [Indexed: 02/05/2023]
Abstract
Intraoperative hypotension (IOH) is a major concern to the anesthesiologist. Its appropriate identification and management require an understanding of the physiology of blood pressure regulation, prudent blood pressure monitoring, and treatment. Even short durations of low mean arterial pressure have been associated with adverse postoperative clinical outcomes. The challenge is for the clinician to respond proactively, address the specific etiology of IOH, and keep in mind any changes to the patient's physiology. Predictive technology, such as the Hypotension Prediction Index, offers the clinician new insight into IOH. It has been shown to predict hypotension up to 15 minutes before occurrence. It also calculates stroke volume variation, dynamic arterial elastance, and left ventricular contractility, which can inform the anesthesiologist of the etiology of IOH to direct management. This new technology has the potential to reduce duration or even prevent IOH. In the authors' opinion, it is an example of how human-machine interaction will contribute to future advances in medicine. Additional studies should evaluate the effects of its use on postoperative outcomes.
Collapse
Affiliation(s)
- Hamdy Awad
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH.
| | | | - Arwa Raza
- Ohio State University College of Medicine, Columbus, OH
| | - Racha Boulos
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Michael Essandoh
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Sujatha Bhandary
- Department of Anesthesiology, Emory University School of Medicine, Atlanta, GA
| | - Ryan Dalton
- Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, OH
| |
Collapse
|
10
|
Affiliation(s)
| | - Sanjay Ganapathi
- Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India
| |
Collapse
|
11
|
Acute psychological stress, autonomic function, and arterial stiffness among women. Int J Psychophysiol 2020; 155:219-226. [PMID: 32619458 DOI: 10.1016/j.ijpsycho.2020.06.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 04/20/2020] [Accepted: 06/26/2020] [Indexed: 11/23/2022]
Abstract
This study aimed to investigate the effect of acute psychological stress on autonomic function and arterial stiffness, and to test a mediating role of changes in autonomic function between acute stress and arterial stiffness. Eighty-five healthy female adults were randomized into either an experimental or control group. The Trier Social Stress Test (TSST) was used to induce acute psychological stress. Autonomic function (measured by pre-ejection period [PEP] from cardiac impedance and high frequency [HF] of heart rate variability [HRV]) and arterial stiffness (measured by carotid and femoral pulse wave velocity [cfPWV] and augmentation index [AIx]) were assessed before and after the TSST. The mean age of the participants was 28.78 (±9.84) years old. Experimental group participants had a significant increase in cfPWV (p = .025) and AIx (p = .017) following the stressor, compared with those in the control group, after controlling for age, body mass index, and systolic blood pressure. However, no significant group differences were observed in changes in PEP (p = .181) and HF (p = .058). Changes in PEP and HF were neither associated with changes in cfPWV (p = .975 and p = .654, respectively), nor in AIx (p = .376 and p = .323, respectively). The results suggest that even a brief period of mild to moderate stress, which does not cause sustainable changes in autonomic function, may still exert significant adverse effects on arterial stiffness. The changes in arterial stiffness were not related to changes in autonomic function. Future experimental studies with several measurement points are recommended to identify distinct effects of stress on autonomic function and arterial stiffness.
Collapse
|
12
|
Morelli J, Briganti A, Fuchs B, Huber Ð, Evans AL, Babic N, Reljić S, Pađen L, Arnemo JM. NON-INVASIVE BLOOD PRESSURE AND OTHER PHYSIOLOGICAL DATA IN CHEMICALLY IMMOBILIZED BROWN BEARS ( URSUS ARCTOS). Data Brief 2020; 30:105646. [PMID: 32420431 PMCID: PMC7214828 DOI: 10.1016/j.dib.2020.105646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Accepted: 04/23/2020] [Indexed: 12/02/2022] Open
Abstract
Free-ranging brown bears (Ursus arctos) were snared and subsequently darted with a combination of xylazine-ketamine in Croatia (n = 5) or darted from a helicopter with a combination of medetomidine-tiletamine-zolazepam in Scandinavia (n = 20). Three adults and one yearling (1 year old) bear were captured in Croatia, with one adult being captured twice. The Scandinavian bears were divided into Group A (yearlings, n = 7) and Group B (subadults, n = 2 and adults, n = 11). The exertion time (time from activation of the trap or from the start of the helicopter chase to recumbency) and the induction time (time from darting to recumbency) were recorded. The rectal temperature (Tr) was measured as soon as possible after induction and then monitored at frequent intervals (varied between individuals) in immobilized bears. Blood pressure (BP) was measured with a non-invasive method (Korotkoff's technique) every 5 minutes. The heart rate (HR), respiratory rate (RR), and arterial haemoglobin oxygen saturation (SpO2) were recorded every 5 minutes. Reliability of the BP monitoring technique, trends of variation of the physiological variables, and the factors related to the capture were assessed. Both exertion and induction times were longer in Croatian bears than in Scandinavian bears. In Croatian bears, the Tr was either constant or slightly decreasing, with hyperthermia recorded in two individuals (Tr > 39.0° C). In Scandinavian bears, 17 of 20 individuals developed an initial hyperthermia. Four of five bears in Croatia and 17 of 20 bears in Scandinavia showed a decreasing trend in systolic and mean BP over time. According to the Korotkoff method, all bears were hypertensive (mean BP > 130 mmHg) with varying severity, and the systolic pressure was significantly lower in yearlings when compared to subadults and adults. Yearlings had significantly (p < 0.05) higher HR than subadults and adults, however there was no significant differences in RR, SpO2, and Tr between the age groups. All Croatian bears and 13 of 20 Scandinavian bears were moderately to severely hypoxemic (SpO2 < 90%). Further studies with simultaneous invasive and non-invasive (Korotkoff) BP monitoring techniques are required to confirm the accuracy of methods used in this study. The data presented here provides evidence of the physiological impact of different capture methods and chemical immobilization of brown bears in Croatia and Scandinavia.
Collapse
Key Words
- BP, blood pressure
- Blood pressure
- Brown bear
- CW/LC, cuff width/limb circumference
- Capture
- DAP, diastolic arterial blood pressure
- GPS, Global Positioning System
- HR, heart rate
- Heart rate
- Hypertension
- IM, intramuscularly
- Korotkoff
- MAP, mean arterial blood pressure
- MTZ, medetomidine-tiletamine-zolazepam
- RR, respiratory rate
- Respiratory rate
- SAP, systolic arterial blood pressure
- SD, Standard Deviation
- SpO2, hemoglobin-oxygen saturation
- Ta, ambient temperature
- Temperature
- Tr, rectal temperature
- VHF, Very High Frequency
- XK, xylazine-ketamine
Collapse
Affiliation(s)
- Jacopo Morelli
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, 2480 Koppang, Norway
| | - Angela Briganti
- Department of Veterinary Sciences, University of Pisa, 56122 San Piero A Grado, Italy
| | - Boris Fuchs
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, 2480 Koppang, Norway
| | - Ðuro Huber
- Department of Biology, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Alina L. Evans
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, 2480 Koppang, Norway
| | - Natarsha Babic
- Department of Biology, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Slaven Reljić
- Department of Biology, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Lana Pađen
- Department of Physiology, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Jon M. Arnemo
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, 2480 Koppang, Norway
- Department of Wildlife, Fish and Environmental Studies, Swedish University of Agricultural Sciences, 901 83 Umeå, Sweden
| |
Collapse
|
13
|
Logan JG, Yun S, Bao Y, Farber E, Farber CR. RNA-sequencing analysis of differential gene expression associated with arterial stiffness. Vascular 2020; 28:655-663. [PMID: 32375599 DOI: 10.1177/1708538120922650] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVES Arterial stiffness is recognized as an important predictor of cardiovascular disease morbidity and mortality, independent of traditional cardiovascular disease risk factors. Given that arterial tissue is not easily accessible, most gene expression studies on arterial stiffness have been conducted on animals or on patients who have undergone by-pass surgeries. In order to obtain a deeper understanding of early changes of arterial stiffness, this study compared transcriptome profiles between healthy adults with higher and lower arterial stiffness. METHODS The sample included 20 healthy female adults without cardiovascular disease. Arterial stiffness was measured by carotid-femoral pulse wave velocity, the "gold-standard" measure of central arterial stiffness. Peripheral blood samples collected to PAXgene™ RNA tubes were used for RNA sequencing (RNA-seq). The potential confounding effects of age, body mass index, and mean arterial pressure were controlled for in RNA-seq analysis. To validate RNA-seq results, quantitative real-time PCR (qRT-PCR) was performed for six selected genes. RESULTS The findings demonstrated that genes including CAPN9, IL32, ERAP2, RAB6B, MYBPH, and miRNA626 were down-regulated, and that MOCS1 gene was up-regulated among the people with higher arterial stiffness. Real-time PCR showed that the changes of CAPN9, IL32, ERAP2, and RAB6B were in concordance with RNA-seq data, and confirmed the validity of the gene expression profiles obtained by RNA-seq analysis. CONCLUSIONS Previous studies have suggested the potential roles of CAPN9, IL32, and ERAP2 in structural changes of the arterial wall through up-regulation of metalloproteinases. However, the current study showed that CAPN9, IL32, and ERAP2 were down-regulated in the individuals with higher arterial stiffness, compared with those with lower arterial stiffness. The unexpected directions of expression of these genes may indicate an effort to maintain vascular homeostasis during increased arterial stiffness among healthy individuals. Further studies are guaranteed to investigate the roles of CAPN9, IL32, and ERAP2 in regulating arterial stiffness in people with and without cardiovascular disease.
Collapse
Affiliation(s)
| | | | - Yongde Bao
- Department of Microbiology, Immunology, and Cancer Biology, University of Virginia, Charlottesville, USA
| | - Emily Farber
- Center for Public Health Genomics, School of Medicine, University of Virginia, Charlottesville, USA
| | - Charles R Farber
- Department of Public Health Sciences and Biochemistry and Molecular Genetics, Center for Public Health Genomics, University of Virginia, Charlottesville, USA
| |
Collapse
|
14
|
Cernat A, Sakshaug JW. Nurse effects on measurement error in household biosocial surveys. BMC Med Res Methodol 2020; 20:45. [PMID: 32106825 PMCID: PMC7047401 DOI: 10.1186/s12874-020-00922-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2019] [Accepted: 02/12/2020] [Indexed: 11/10/2022] Open
Abstract
Background Biosocial survey data are in high demand, yet little is known about the measurement quality of health measures collected by nurses in respondents’ homes. Our objective was to analyze the degree to which nurses influence measurement in anthropometric and physical performance indicators collected from respondents in two nationally-representative UK biosocial surveys. Methods The English Longitudinal Survey of Ageing and the UK Household Longitudinal Study – Understanding Society were used to analyze fourteen anthropometric and physical performance measures covering weight, height, pulse, grip strength, and lung capacity. Cross-classified multilevel models were used to estimate “nurse effects” on measurement error. Results Overall, there is a medium effect of nurses on measurement. Across all measures collected in both studies, nurses explain around 13% of all measurement variation. Variation in specific measures range between approximately 2 and 25%. Grip strength and lung capacity are more heavily influenced by nurses than are height, weight, and pulse. Lastly, nurse characteristics explain only a very small proportion of nurse measurement variation. Conclusion Objective health measures collected by nurses in household biosocial surveys are susceptible to non-trivial amounts of measurement variation. Nurse ID numbers should be regularly included in biosocial data releases to allow researchers to account for this unnecessary source of variation. Further, researchers are advised to conduct sensitivity analyses using control variables that account for nurse variation to confirm whether their substantive findings are influenced by nurse measurement effects.
Collapse
Affiliation(s)
- Alexandru Cernat
- University of Manchester, Humanities Bridgford Street, Manchester, M13 9PL, UK.
| | - Joseph W Sakshaug
- Ludwig Maximilian University of Munich, Munich, Germany.,University of Mannheim, Mannheim, Germany.,Institute for Employment Research, Regensburger Strasse 104, 90478, Nuremberg, Germany
| |
Collapse
|
15
|
Morelli J, Briganti A, Fuchs B, Huber Ð, Evans AL, Reljić S, Arnemo JM. Comparison of two non-invasive arterial blood pressure monitoring techniques in brown bears ( Ursus arctos). Vet Anim Sci 2020; 9:100094. [PMID: 32734104 PMCID: PMC7386746 DOI: 10.1016/j.vas.2020.100094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 01/11/2020] [Accepted: 01/15/2020] [Indexed: 11/25/2022] Open
Abstract
Monitoring arterial blood pressure (BP), represents a more accurate evaluation of hemodynamics than heart rate alone and is essential for preventing and treating intra- and post-operative complications in wildlife chemical immobilization. The objectives of the study were to test the correlation between standard oscillometry and Korotkoff's technique in anesthetized free-ranging brown bears in Croatia and Scandinavia and to assess the blood pressure in both locations. Five bears were snared and darted with xylazine and ketamine in Croatia, and 20 bears were darted from a helicopter with medetomidine and tiletamine-zolazepam in Scandinavia. Blood pressure was simultaneously measured with both techniques every 5 minutes. Correlation between techniques, trends of BP variation, and the factors of the capture which likely influenced BP were assessed. Successful measurements of BP were achieved in 93% of all attempts with the Korotkoff's technique but in only 29% of all attempts with oscillometry. The latter method mostly provided lower values of BP compared to Korotkoff's technique in yearlings. Most bears showed a decreasing trend in systolic and mean BP over time, consistent between the two techniques. All bears were hypertensive: the auscultatory technique detected moderate to severe systolic hypertension in 25% and 84% of bears in Croatia and in Scandinavia, respectively, with significantly higher BP in subadults and adults compared to yearlings. Only Korotkoff's method resulted in a reliable and effective tool for BP assessment in brown bears. The anesthetic protocols used in the present study in association with the capture methods produced hypertension in all animals.
Collapse
Key Words
- BP, blood pressure
- Blood pressure
- Brown bear
- CW/LC, cuff width/limb circumference
- DAP, diastolic arterial blood pressure
- GPS, Global Positioning System
- HR, heart rate
- Hypertension
- IM, intramuscularly
- Korotkoff
- LoA, limit of agreement
- MAP, mean arterial blood pressure
- MZT, medetomidine-zolazepam-tiletamine
- Oscillometry
- SAP, systolic arterial blood pressure
- SD, Standard Deviation
- SpO2, hemoglobin-oxygen saturation
- Sphygmomanometer
- VHF, Very High Frequency
- XK, xylazine-ketamine
Collapse
Affiliation(s)
- Jacopo Morelli
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Anne Evenstadvegen 80, 2480 Koppang, Norway
| | - Angela Briganti
- Department of Veterinary Sciences University of Pisa, Via Livornese, 56122 San Piero A Grado, Italy
| | - Boris Fuchs
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Anne Evenstadvegen 80, 2480 Koppang, Norway
| | - Ðuro Huber
- Department of Biology, Faculty of Veterinary Medicine, University of Zagreb, Heinzelova ul. 55, 10000 Zagreb, Croatia
| | - Alina L Evans
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Anne Evenstadvegen 80, 2480 Koppang, Norway
| | - Slaven Reljić
- Department of Biology, Faculty of Veterinary Medicine, University of Zagreb, Heinzelova ul. 55, 10000 Zagreb, Croatia
| | - Jon M Arnemo
- Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Anne Evenstadvegen 80, 2480 Koppang, Norway.,Department of Wildlife, Fish and Environmental Studies, Swedish University of Agricultural Sciences, Skogsmarksgränd 17, 901 83 Umeå, Sweden
| |
Collapse
|
16
|
Eley VA, Christensen R, Guy L, Dodd B. Perioperative Blood Pressure Monitoring in Patients With Obesity. Anesth Analg 2019; 128:484-491. [PMID: 30059399 DOI: 10.1213/ane.0000000000003647] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Blood pressure monitoring plays a key part in the preoperative, intraoperative, and postoperative care of all patients. In patients with obesity, hypertension indicates increased metabolic and surgical risk and may signal the presence of significant medical comorbidities, including obstructive sleep apnea. Avoidance of hypertension postoperatively is necessary to minimize bleeding risk after surgery. Hypotension in the postoperative period may be the first sign of significant complications that require urgent management. With the problem of being overweight or obese now affecting two-thirds of adults in Western countries, the proportion of patients with obesity in perioperative environments is similarly increasing. Detection of aberrations in blood pressure is contingent on the accuracy of blood pressure measurement methods. Patients with obesity tend to have a large arm circumference and "cone-shaped arms." Standard blood pressure cuffs fit such patients poorly, and this compromises the accuracy of measurements. Alternatives to arm blood pressure cuffs, some made specifically for individuals with obesity, have been evaluated but are not widely available to clinicians. This focused narrative review will discuss the relevance of hypertension management in the care of patients with obesity, highlight the currently available methods for perioperative monitoring of blood pressure, and explore the opportunities that exist to improve the perioperative blood pressure care in patients with obesity undergoing surgical procedures.
Collapse
Affiliation(s)
- Victoria A Eley
- From the Department of Anaesthesia and Perioperative Medicine, The Royal Brisbane and Women's Hospital, Herston, Queensland, Australia.,Faculty of Medicine, The University of Queensland, St Lucia, Queensland, Australia
| | - Rebecca Christensen
- From the Department of Anaesthesia and Perioperative Medicine, The Royal Brisbane and Women's Hospital, Herston, Queensland, Australia.,Faculty of Medicine, The University of Queensland, St Lucia, Queensland, Australia
| | - Louis Guy
- From the Department of Anaesthesia and Perioperative Medicine, The Royal Brisbane and Women's Hospital, Herston, Queensland, Australia.,Faculty of Medicine, The University of Queensland, St Lucia, Queensland, Australia
| | - Benjamin Dodd
- Faculty of Medicine, The University of Queensland, St Lucia, Queensland, Australia.,Department of Surgery, The Royal Brisbane and Women's Hospital, Herston, Queensland, Australia
| |
Collapse
|
17
|
Kramer HJ, Townsend RR, Griffin K, Flynn JT, Weiner DE, Rocco MV, Choi MJ, Weir MR, Chang TI, Agarwal R, Beddhu S. KDOQI US Commentary on the 2017 ACC/AHA Hypertension Guideline. Am J Kidney Dis 2019; 73:437-458. [PMID: 30905361 PMCID: PMC6740329 DOI: 10.1053/j.ajkd.2019.01.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 01/08/2019] [Indexed: 02/07/2023]
Abstract
Hypertension is a modifiable risk factor for cardiovascular morbidity and mortality and reduction of elevated blood pressure (BP) remains an important intervention for slowing kidney disease progression. Over the past decade, the most appropriate BP target for initiation and titration of BP-lowering medications has been an area of intense research and debate within the clinical community. In 2017, the American College of Cardiology and the American Heart Association (ACC/AHA) in conjunction with several other professional societies released new hypertension guidelines based on data from a systematic review of clinical trials and observational data. While many of the recommendations in the ACC/AHA hypertension guideline are relevant to nephrology practice, BP targets and management strategies for patients receiving dialysis are not discussed. This Kidney Disease Outcomes Quality Initiative (KDOQI) commentary focuses largely on recommendations from the ACC/AHA hypertension guidelines that are pertinent to individuals at risk of chronic kidney disease or with non-dialysis-dependent chronic kidney disease. This KDOQI commentary also includes a brief discussion of the consensus statement regarding hypertension diagnosis and management for adults receiving maintenance dialysis published by the European Renal and Cardiovascular Medicine Working Group of the European Renal Association-European Dialysis and Transplant Association (ERA-EDTA) and the Hypertension and the Kidney working group of the European Society of Hypertension. Overall, we support the vast majority of the ACC/AHA recommendations and highlight select areas in which best diagnosis and treatment options remain controversial.
Collapse
Affiliation(s)
- Holly J Kramer
- Department of Public Health Sciences, Loyola University Chicago Stritch School of Medicine, Maywood; Department of Medicine, Loyola University Chicago Stritch School of Medicine, Maywood; Hines VA Medical Center, Hines, IL.
| | - Raymond R Townsend
- Department of Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA
| | - Karen Griffin
- Department of Medicine, Loyola University Chicago Stritch School of Medicine, Maywood; Hines VA Medical Center, Hines, IL
| | - Joseph T Flynn
- Department of Pediatrics, University of Washington School of Medicine, Seattle WA
| | | | - Michael V Rocco
- Department of Medicine, Wake Forest School of Medicine, Winston-Salem, NC
| | - Michael J Choi
- Department of Medicine, Johns Hopkins School of Medicine
| | - Matthew R Weir
- Division of Nephrology, Department of Medicine, University of Maryland School of Medicine, Baltimore, MD
| | - Tara I Chang
- Department of Medicine, Stanford Medical School, Palo Alto, CA
| | - Rajiv Agarwal
- Department of Medicine, Indiana University School of Medicine, Indianapolis, IN
| | | |
Collapse
|
18
|
Parker BK, Manning S, Winters ME. The Crashing Obese Patient. West J Emerg Med 2019; 20:323-330. [PMID: 30881553 PMCID: PMC6404698 DOI: 10.5811/westjem.2018.12.41085] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Revised: 12/16/2018] [Accepted: 12/14/2018] [Indexed: 01/11/2023] Open
Abstract
Emergency physicians (EP) frequently resuscitate and manage critically ill patients. Resuscitation of the crashing obese patient presents a unique challenge for even the most skilled physician. Changes in anatomy, metabolic demand, cardiopulmonary reserve, ventilation, circulation, and pharmacokinetics require special consideration. This article focuses on critical components in the resuscitation of the crashing obese patient in the emergency department, namely intubation, mechanical ventilation, circulatory resuscitation, and pharmacotherapy. To minimize morbidity and mortality, it is imperative that the EP be familiar with the pearls and pitfalls discussed within this article.
Collapse
Affiliation(s)
- Brian K Parker
- University of Texas San Antonio, Department of Emergency Medicine, San Antonio, Texas
| | - Sara Manning
- University of Maryland School of Medicine, Department of Emergency Medicine, Baltimore, Maryland
| | - Michael E Winters
- University of Maryland School of Medicine, Department of Emergency Medicine, Baltimore, Maryland
| |
Collapse
|
19
|
Denison FC, Aedla NR, Keag O, Hor K, Reynolds RM, Milne A, Diamond A. Care of Women with Obesity in Pregnancy. BJOG 2018; 126:e62-e106. [DOI: 10.1111/1471-0528.15386] [Citation(s) in RCA: 86] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
20
|
Zeugswetter FK, Tichy A, Weber K. Radial vs coccygeal artery Doppler blood pressure measurement in conscious cats. J Feline Med Surg 2018; 20:968-972. [PMID: 29132245 PMCID: PMC11129233 DOI: 10.1177/1098612x17740795] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
Objectives The aims of the study were to compare the results of systolic blood pressure (SBP) measurements at the radial and coccygeal artery by Doppler ultrasonography and to assess the impact of gender, age, body weight, body condition score (BCS) and stress score on disagreements. Methods Eighty cats were included in this prospective, block randomised crossover trial. Blood pressure measurements were performed at home, during hospitalisation or in a local animal shelter by a single trained observer according to the latest ISFM consensus guidelines. Statistical analysis included Spearman's correlation and ANOVA. Results Measurement or site order had no effect on blood pressure measurements ( P = 0.157, P = 0.965). Correlation of radial and coccygeal SBP was moderate (rsp = 0.519, P <0.001) and measurements at the tail were by mean 18.7 ± 37 mmHg higher. The differences between the measuring sites were neither correlated with age (rsp = 0.044, P = 0.710) nor with body weight (rsp = 0.122, P = 0.337). A significant effect of BCS ( P = 0.016), but not gender ( P = 0.246) or stress score ( P = 0.424) was identified. Of the 25 cats with a coccygeal SBP ⩾170 mmHg, 14 (56%) were categorised as mildly hypertensive or normotensive when measurements were performed at the forelimb. Conclusions and relevance Choice of the measuring site, coccygeal vs radial artery, has a significant impact on Doppler ultrasonographic SBP results. In many cats, these discrepancies are huge and would certainly affect treatment decisions. Possible explanations include cone-shaped tails, especially in obese cats, leading to distal gapping or slippage of cylindrical cuffs and peripheral pulse pressure amplification. Further studies are urgently needed to clarify whether the discordances are artefacts or have a pathological background.
Collapse
Affiliation(s)
- Florian K Zeugswetter
- Clinical Department for Small Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Alexander Tichy
- Platform Bioinformatics and Biostatistics, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Katharina Weber
- Clinical Department for Small Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria
| |
Collapse
|
21
|
Adequacy of validation of wide-range cuffs used with home blood pressure monitors: a systematic review. Blood Press Monit 2018; 23:219-224. [PMID: 30074520 DOI: 10.1097/mbp.0000000000000344] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Wide-range 'one-size-fits-all' blood pressure (BP) cuffs are commonly sold with home BP monitors. Assessment of the accuracy of these cuffs is important because they do not adhere to the basic principles of proper cuffing. The aim of this systematic review was to review the published validation data evaluating the accuracy of wide-range cuffs. METHODS Medline (1946-2017) and the Web of Science (2002-2017) were searched for home BP device validation studies carried out according to an established validation protocol and published in English. Studies that included assessment of a wide-range cuff (defined as a cuff with a range of 15 cm or greater) were sought. The quality of wide-range cuff assessment was scored on a three-point scale, with one point assigned each for (a) passing validation criteria, (b) full evaluation across the entire cuff range, and (c) reporting of results stratified by arm circumference. RESULTS Twenty-five validation studies were identified, reporting data on 28 device/wide-range cuff combinations. Study quality was poor - 21 studies received a score of one and four studies received a score of two. All studies were awarded one point because the device-cuff combination passed the chosen validation protocol. Only two studies ensured full assessment of the cuff range; however, neither study reported results stratified by arm circumference. Of the two studies that did report results by arm circumference, one showed a potentially direct linear relationship between arm circumference and device-observer error. CONCLUSION Despite their widespread use, the evidence supporting use of wide-range home BP cuffs is inadequate.
Collapse
|
22
|
Critchley JA, Cooper RS. Blood pressures are going down worldwide-but why? Int J Epidemiol 2018; 47:884-886. [PMID: 29897532 DOI: 10.1093/ije/dyy123] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/31/2018] [Indexed: 11/13/2022] Open
Affiliation(s)
- Julia A Critchley
- Public Health Research Institute, St George's University, London, UK
| | - Richard S Cooper
- Department of Public Health Sciences, Loyola University Medical School, Maywood, IL, USA
| |
Collapse
|
23
|
Lobo GAR, Nowak PM, Panigassi AP, Lima AIF, Araujo Júnior E, Nardozza LMM, Pares DBS. Validation of Fetal Medicine Foundation algorithm for prediction of pre-eclampsia in the first trimester in an unselected Brazilian population. J Matern Fetal Neonatal Med 2017; 32:286-292. [PMID: 28889785 DOI: 10.1080/14767058.2017.1378332] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE The objective of this study is to evaluate the predictive performance of the Fetal Medicine Foundation (FMF) algorithm for prediction of preeclampsia (PE) between 11 and 14 weeks of gestation in an unselected Brazilian population. METHODS We conducted a prospective cohort study with 617 singleton pregnancies of unselected risk. Biophysical markers (mean pulsatility index, mean arterial pressure) and biochemical markers (placental growth factor (PLGF) and PAPP-A) were inserted into the FMF software and converted into multiples of the median (MoM). The subjects were divided into five groups: early-onset PE, parturition <34 weeks' gestation; preterm PE, parturition <37 weeks; PE, parturition at any gestational age; gestational hypertension (GH); and control group. Areas under the receiver operating characteristics curve (AUC) were calculated for the outcomes. RESULTS Among 617 patients, seven developed early-onset PE, 18 developed preterm PE (seven early PE plus 11 delivered between 34 and 36 + 6 weeks gestation), 34 developed PE (18 preterm PE plus 16 delivered after 37-week gestation), 12 pregnant women developed GH, and 517 women comprised the control group. The best predictive performance using the FMF algorithm occurred in the early-onset PE group, with AUC = 0.946 (95% CI 0.919-0.973) and the detection rate of 28.6% and 85.7% for 5% and 10% false-positive (FP), respectively. CONCLUSIONS The FMF algorithm to predict PE was effective in a Brazilian population, mainly in the early-onset form of the disease at 10% FP.
Collapse
Affiliation(s)
- Guilherme Antonio Rago Lobo
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| | - Paulo Martin Nowak
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| | - Ana Paula Panigassi
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| | - Angélia Iara Felipe Lima
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| | - Edward Araujo Júnior
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| | | | - David Baptista Silva Pares
- a Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil
| |
Collapse
|
24
|
Treskes RW, Wolterbeek R, van der Velde ET, Eindhoven DC, Schalij MJ. Comparison of the diagnostic accuracy of four smartphone-compatible blood pressure monitors in post-myocardial infarction patients. J Telemed Telecare 2017; 24:404-409. [PMID: 28457182 DOI: 10.1177/1357633x17704092] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Introduction Smartphone-compatible blood pressure devices may be a good alternative to enable self-measurement of blood pressure by patients. Furthermore, automatic transferral of data to the hospital allows for remote monitoring. To our knowledge, no study has compared four of these smartphone-compatible blood pressure devices. Methods Patients who were followed up for acute myocardial infarction were asked to participate during their outpatient clinic visit. After five minutes of rest, six blood pressure devices were applied. The order was randomised. Four devices were smartphone-compatible. One device was an automated oscillometric device. One device was a handheld aneroid sphygmomanometer (reference device). All measurements were compared using a linear mixed model. Results A total of 43 patients (62.7 ± 11.3 years, 79% male) were included. Compared to the reference device, four blood pressure monitors yielded a significant higher mean systolic blood pressure and four monitors yielded a significant higher diastolic BP. One device yielded a non-significant lower mean systolic blood pressure and one device yielded a non-significant higher mean diastolic blood pressure. Except for one blood pressure device, all mean differences were smaller than 5 mmHg. Conclusion In this study, average inter-device variability was shown to be statistically significant, however four devices remained within the predefined range of 5 mmHg for both systolic and diastolic blood pressures.
Collapse
Affiliation(s)
- Roderick W Treskes
- 1 Department of Cardiology, Leiden University Medical Center, The Netherlands
| | - Ron Wolterbeek
- 2 Department of Medical Statistics, Leiden University Medical Center, The Netherlands
| | | | | | - Martin J Schalij
- 1 Department of Cardiology, Leiden University Medical Center, The Netherlands
| |
Collapse
|
25
|
Pouwels S, Lascaris B, Nienhuijs SW, Arthur Bouwman R, Buise MP. Validation of the Nexfin® non-invasive continuous blood pressure monitoring validated against Riva-Rocci/Korotkoff in a bariatric patient population. J Clin Anesth 2017; 39:89-95. [PMID: 28494917 DOI: 10.1016/j.jclinane.2017.03.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2016] [Revised: 03/22/2017] [Accepted: 03/23/2017] [Indexed: 11/17/2022]
Abstract
STUDY OBJECTIVE The present study aimed to validate the Nexfin® monitor and to assess the accuracy compared to classical sphygmomanometry (Riva-Rocci/Korotkoff (RRK)) blood pressure (BP) measurements in patients with obesity scheduled for bariatric surgery. DESIGN Validation study. SETTING Outpatient clinic for bariatric surgery. PATIENTS 33 patients scheduled for bariatric surgery. MEASUREMENTS The validation process was done according to the protocols developed by the European Society of Hypertension from 2010. The Nexfin® monitor (Edwards Lifesciences/BMEYE B.V., Amsterdam, The Netherlands) calculates beat-to-beat blood pressure from finger pulse wave analysis. Measurements of systolic and diastolic BP were obtained using classical sphygmomanometry and the Nexfin® alternatingly. MAIN RESULTS In total 99 pairs of BP measurements were used. The device failed pass phase 1 as 65 systolic readings fell within 5mmHg (73 required). And 61, 76 and 90 diastolic readings fell within 5, 10 and 15mmHg respectively. Finally, it failed to pass phase 2 as 23 patients for systolic and 25 for diastolic had at least 2/3 of their comparisons falling within 5mmHg (24 required) but 10 subjects for systolic and 8 for diastolic had all three comparisons more than 5mmHg different from the RRK readings (zero allowed). Mean differences were 7.8±6.9mmHg for SBP and 8.0±7.2mmHg for DBP. CONCLUSION Using the revised protocol, the Nexfin® device was not able to pass validation. However using the original protocol, the Nexfin® device passed phase 1 and 2.1 of the validation process and failed to pass phase 2.2.
Collapse
Affiliation(s)
- Sjaak Pouwels
- Department of Surgery, St Franciscus & Vlietland, Schiedam, The Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, The Netherlands.
| | - Bianca Lascaris
- Department of Anaesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
| | - Simon W Nienhuijs
- Department of Surgery, Catharina Hospital, Eindhoven, The Netherlands
| | - R Arthur Bouwman
- Department of Anaesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
| | - Marc P Buise
- Department of Anaesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
| |
Collapse
|
26
|
Destefano RM, Schmitt FRDA, Starke S, Helena ETDS. Adequacy of sphygmomanometer cuff to brachial circumference of people attended in Primary Health Care Centers. REVISTA BRASILEIRA DE EPIDEMIOLOGIA 2017; 20:81-90. [PMID: 28513796 DOI: 10.1590/1980-5497201700010007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2015] [Accepted: 09/01/2016] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE: To evaluate the adequacy of sphygmomanometer cuff to brachial circumference (BC) of individuals treated at Primary Health Care Centers. METHODS: Epidemiological, observational, and quantitative cross-sectional study. A total of 381 blood pressure (BP) readings conducted by nursing professionals were observed at 18 service units selected by drawing, considering two modalities of care centers. The correct use of the cuff was the main outcome variable. The BC was measured using inelastic measuring tape. The tests used for statistical analysis were Student's t-test, χ2, or Fisher's exact test. RESULTS: The measurement of BC ranged from 19.5 to 45.0 cm (mean = 30.4; standard deviation - SD = 4.3). Among the BP measurements, 218 (57.2%) of them were conducted with the appropriately sized cuff, being more frequent in the units with Family Health Teams (59.6 versus 40.4; p < 0.001). Ninety-three (24.2%) BC measurements were < 27 cm and 63 (16.5%) were > 34 cm. The adult cuff was used correctly 209 (59.4%) times and the large adult cuff was used correctly 9 (31.0%) times. CONCLUSION: The study found an inadequacy in the use of the cuff in 42.8% of blood pressure readings in the Primary Health Care Centers. Similar studies should be performed in other cities and areas to estimate the effect of this problem in the diagnosis and monitoring of systemic arterial hypertension (SAH).
Collapse
Affiliation(s)
| | | | - Siegmar Starke
- Programa de Pós-graduação em Saúde Coletiva da Universidade Regional de Blumenau - Blumenau (SC), Brasil
| | | |
Collapse
|
27
|
Irving G, Holden J, Stevens R, McManus RJ. Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review. BMJ Open 2016; 6:e012429. [PMID: 27810973 PMCID: PMC5129068 DOI: 10.1136/bmjopen-2016-012429] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVE To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. DESIGN Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. DATA SOURCES MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. ELIGIBILITY CRITERIA Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. RESULTS 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. CONCLUSIONS BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered.
Collapse
Affiliation(s)
- Greg Irving
- Department of Primary Care, Institute of Public Health and Primary Care, University of Cambridge, Cambridge, UK
| | - John Holden
- Department of Garswood Surgery, Garswood, UK
| | - Richard Stevens
- Nuffield Department of Primary Care Health Sciences, NIHR School for Primary Care Research, University of Oxford, Oxford, UK
| | - Richard J McManus
- Nuffield Department of Primary Care Health Sciences, NIHR School for Primary Care Research, University of Oxford, Oxford, UK
| |
Collapse
|
28
|
Umana E, Ahmed W, Fraley MA, Alpert MA. Comparison of Oscillometric and Intraarterial Systolic and Diastolic Blood Pressures in Lean, Overweight, and Obese Patients. Angiology 2016; 57:41-5. [PMID: 16444455 DOI: 10.1177/000331970605700106] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
To assess the effect of obesity on blood pressure measurement the authors obtained simultaneous oscillometric and intraarterial systolic and diastolic blood pressures on 188 lean, overweight, class I/II obese, and class III obese subjects. Oscillometric arm cuff/bladder size was selected in accordance with standard guidelines. Oscillometry significantly underestimated systolic and significantly overestimated diastolic blood pressures in each of the 4 weight groups studied. The differences between oscillometric and intraarterial systolic and diastolic pressures were not significantly different among lean, overweight, class I/II obese, and class III obese subjects. Thus, obesity per se does not influence the accuracy of blood pressure measurement. However, oscillometric blood pressure measurement is associated with significant error when compared to intraarterial blood pressure.
Collapse
Affiliation(s)
- Ernesto Umana
- Department of Medicine, University of South Alabama Medical Center, Mobile, AL, USA
| | | | | | | |
Collapse
|
29
|
Ringrose JS, McLean D, Ao P, Yousefi F, Sankaralingam S, Millay J, Padwal R. Effect of Cuff Design on Auscultatory and Oscillometric Blood Pressure Measurements. Am J Hypertens 2016; 29:1063-9. [PMID: 27099256 DOI: 10.1093/ajh/hpw034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Accepted: 03/15/2016] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Two-piece blood pressure (BP) cuffs are the historical cuff standard. Use of 1-piece cuffs is increasing. Substituting 1-piece for 2-piece cuffs has an unknown effect on measurement accuracy. We compared these cuff types in a 2-phase study using auscultatory and oscillometric techniques. METHODS Consenting subjects (aged ≥18 years) with BP levels between 80 and 220mm Hg/50 and 120mm Hg and arm circumferences between 25 and 43cm were studied using the International Standards Organization (ISO) 2013 protocol (modified). A Baum 2-piece cuff was used as the reference standard. A 1-piece Welch Allyn cuff was the comparator. In phase 1 (2-observer auscultation with a mercury sphygmomanometer), 88 subjects were required to obtain 255 paired BP determinations. In phase 2 (oscillometric measurement with a Spacelabs 90207 device), 85 subjects were studied. Each phase was analyzed separately using paired t-tests. RESULTS Phase 1 mean age was 54.2±20.5 years, mean arm circumference was 29.9±3.7cm, 60% were female, and 32% had hypertension. One-piece cuff mean BPs were lower than the 2-piece cuff means (115.5±15.5/66.4±9.3 vs. 117.8±15.2/67.9±9.2; difference of -2.4±3.6/-1.5±2.4; P values <0.0001 for systolic and diastolic comparisons). Phase 2 mean age was 52.8±20.8 years, mean arm circumference was 29.4±3.9cm, 67% were female, and 38% had hypertension. Mean BPs were lower for the 1-piece compared to the 2-piece cuff (116.5±12.8/67.1±8.1 vs. 120.8±13.5/70.4±8.5; difference of -4.4±3.6/-3.3±2.7; P values <0.0001 for both). CONCLUSIONS Mean BP is lower with 1-piece cuffs vs. 2-piece cuffs. Differences are greater with oscillometry. When performing validation studies and measurements for clinical purposes, cuff type should be taken into account.
Collapse
Affiliation(s)
| | - Donna McLean
- Faculty of Nursing, University of Alberta, Edmonton, Alberta, Canada
| | - Peter Ao
- Department of Medicine, University of Alberta, Edmonton, Alberta, Canada
| | - Farahnaz Yousefi
- Department of Medicine, University of Alberta, Edmonton, Alberta, Canada
| | | | - Jack Millay
- AccurateBloodPressure.com , Beaverton, Oregon, USA
| | - Raj Padwal
- Department of Medicine, University of Alberta, Edmonton, Alberta, Canada; Alberta Diabetes Institute, Edmonton, Alberta, Canada; Mazankowski Alberta Heart Institute, Edmonton, Alberta, Canada.
| |
Collapse
|
30
|
Emergency Medical Service Providers' Perspectives towards Management of the Morbidly Obese. Prehosp Disaster Med 2016; 31:471-4. [PMID: 27492275 DOI: 10.1017/s1049023x16000595] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Obesity is a growing epidemic in the United States with increasing burden to the health care system. Management and transport of the morbidly obese (MO) pose challenges for Emergency Medical Services (EMS) providers. Though equipment and resources are being directed to the transport of the obese, little research exists to guide these efforts. To address this, the author of this study sought to assess EMS providers' perspectives on the challenges of caring for MO patients. METHODS An anonymous, web-based survey was distributed to all active providers of prehospital transport of a large, urban, fire-based EMS system to evaluate the challenges of MO patients. The definition of MO was left up to the provider. This survey looked at various components of transport: lifting, transport time, airway management, establishing intravenous access, drug administration, as well as demographics, equipment, and education needs. The survey contained yes/no, rank-order, and Likert scale questions. Data were analyzed using descriptive statistics. The study was approved by the University of Miami (Miami, Florida USA) Institutional Review Board. RESULTS Of survey participants, 71.9% felt the average weight of their patients had increased, and 100% reported to have transported a MO patient. Of calls made to EMS, 25% were only for assistance in the house and another 25% were for non-emergent transport to a health care facility; shortness of breath was the most common emergent complaint. Of specific challenges to properly care for MO patients, 94.4 % ranked lifting and/or moving the patient highest, followed by airway management, intravenous access, and measuring vital signs. A total of 43.8% of respondents felt that MO patients require at least six to eight EMS personnel to transport patients while 31.8% felt more than eight providers were necessary. Greater than 81.3% felt it would be beneficial to receive more training and 90.4% felt more equipment was needed. Of participants, 68.8 % felt that MO patients did not receive the same standard of care. CONCLUSIONS Surveyed participants reported that patient's weights are increasing with all having transported a MO patient. Despite the majority of transports being for non-emergent problems, providers felt more training would be beneficial, that equipment available does not meet needs, and that the MO pose challenges to appropriate patient care. Cienki JJ . Emergency Medical Service providers' perspectives towards management of the morbidly obese. Prehosp Disaster Med. 2016;31(5):471-474.
Collapse
|
31
|
De Jong A, Deras P, Martinez O, Latry P, Jaber S, Capdevila X, Charbit J. Relationship between Obesity and Massive Transfusion Needs in Trauma Patients, and Validation of TASH Score in Obese Population: A Retrospective Study on 910 Trauma Patients. PLoS One 2016; 11:e0152109. [PMID: 27010445 PMCID: PMC4807035 DOI: 10.1371/journal.pone.0152109] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2016] [Accepted: 02/29/2016] [Indexed: 11/18/2022] Open
Abstract
Background Prediction of massive transfusion (MT) is challenging in management of trauma patients. However, MT and its prediction were poorly studied in obese patients. The main objective was to assess the relationship between obesity and MT needs in trauma patients. The secondary objectives were to validate the Trauma Associated Severe Hemorrhage (TASH) score in predicting MT in obese patients and to use a grey zone approach to optimize its ability to predict MT. Methods and Findings An observational retrospective study was conducted in a Level I Regional Trauma Center Trauma in obese and non-obese patients. MT was defined as ≥10U of packed red blood cells in the first 24h and obesity as a BMI≥30kg/m². Between January 2008 and December 2012, 119 obese and 791 non-obese trauma patients were included. The rate of MT was 10% (94/910) in the whole population. The MT rate tended to be higher in obese patients than in non-obese patients: 15% (18/119, 95%CI 9‒23%) versus 10% (76/791, 95%CI 8‒12%), OR, 1.68 [95%CI 0.97‒2.92], p = 0.07. After adjusting for Injury Severity Score (ISS), obesity was significantly associated with MT rate (OR, 1.79[95%CI 1.00‒3.21], p = 0.049). The TASH score was higher in the obese group than in the non-obese group: 7(4–11) versus 5(2–10)(p<0.001). The area under the ROC curves of the TASH score in predicting MT was very high and comparable between the obese and non-obese groups: 0.93 (95%CI, 0.89‒0.98) and 0.94 (95%CI, 0.92‒0.96), respectively (p = 0.80). The grey zone ranged respectively from 10 to 13 and from 9 to 12 in obese and non obese patients, and allowed separating patients at low, intermediate or high risk of MT using the TASH score. Conclusions Obesity was associated with a higher rate of MT in trauma patients. The predictive performance of the TASH score and the grey zones were robust and comparable between obese and non-obese patients.
Collapse
Affiliation(s)
- Audrey De Jong
- Trauma Intensive Care & Critical Care Unit, Lapeyronie University Hospital, Montpellier, France.,Intensive Care Unit & Anesthesiology Department, Saint-Eloi University Hospital, Montpellier, France.,INSERM U1046 Montpellier, France
| | - Pauline Deras
- Trauma Intensive Care & Critical Care Unit, Lapeyronie University Hospital, Montpellier, France
| | - Orianne Martinez
- Trauma Intensive Care & Critical Care Unit, Lapeyronie University Hospital, Montpellier, France
| | | | - Samir Jaber
- Intensive Care Unit & Anesthesiology Department, Saint-Eloi University Hospital, Montpellier, France.,INSERM U1046 Montpellier, France
| | - Xavier Capdevila
- Trauma Intensive Care & Critical Care Unit, Lapeyronie University Hospital, Montpellier, France
| | - Jonathan Charbit
- Trauma Intensive Care & Critical Care Unit, Lapeyronie University Hospital, Montpellier, France
| |
Collapse
|
32
|
Change in the association of body mass index and systolic blood pressure in Germany - national cross-sectional surveys 1998 and 2008-2011. BMC Public Health 2015. [PMID: 26209098 PMCID: PMC4514940 DOI: 10.1186/s12889-015-2023-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Background A recent weakening and even decoupling of the association of body mass index (BMI) and systolic blood pressure (SBP) in population data was reported, i. a. for Western Europe. Methods The association of BMI and SBP in recent cross-sectional population data from Germany was investigated in participants aged 18–79 years with BMI 17.5-40 kg/m2 from national health examination surveys 1998 (n = 6,931) and 2008–2011 (n = 6,861) in Germany. The association was analyzed both in the overall samples and in participants without antihypertensive medication. Results From 1998 to 2008–11, age- and sex-standardized mean SBP decreased from 129.0 (CI 128.2-129.7) to 124.1 (123.5-124.6) mmHg in all participants and from 126.0 (125.4-126.7) to 122.3 (121.7-122.8) mmHg among persons not on antihypertensive medication. The proportion of persons treated with antihypertensives augmented from 19.2 % (17.7-20.8) to 25.3 % (24.0-26.6). Mean BMI remained constant at around 27 kg/m2 with a slight increase in obesity prevalence. BMI was positively associated with SBP both in 1998 and 2008–11, yet the association tended to level out with increasing BMI suggesting a non-linear association. The strength of the BMI-SBP-association decreased over time in all and untreated men. In women, the association weakened in the overall sample, but remained similarly strong in untreated women. The unadjusted linear regression models were used to estimate the increase in SBP within 5-unit BMI increases. E. g. for men in 1998, SBP was higher by 7.0 mmHg for a BMI increase from 20 to 25 kg/m2 and by 3.6 mmHg for BMI 30 to 35 kg/m2. The corresponding values for 2008–11 were 3.8 mmHg and 1.7 mmHg. Conclusions The cross-sectional association of BMI and SBP decreased between 1998 and 2008–11 in Germany, however it did not disappear and it is in part explained by improvements in the diagnosis and treatment of high blood pressure. Electronic supplementary material The online version of this article (doi:10.1186/s12889-015-2023-8) contains supplementary material, which is available to authorized users.
Collapse
|
33
|
Jeve YB, Konje JC, Doshani A. Placental dysfunction in obese women and antenatal surveillance strategies. Best Pract Res Clin Obstet Gynaecol 2014; 29:350-64. [PMID: 25457859 DOI: 10.1016/j.bpobgyn.2014.09.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Accepted: 09/04/2014] [Indexed: 10/24/2022]
Abstract
This review is aimed at discussing placental dysfunction in obesity and its clinical implication in pregnancy as well as an antenatal surveillance strategy for these women. Maternal obesity is associated with adverse perinatal outcome. Obesity is an independent risk factor for fetal hyperinsulinaemia, birthweight and newborn adiposity. Maternal obesity is associated with childhood obesity and obesity in adult life. Obesity induces a low-grade inflammatory response in placenta, which results in short- and long-term programming of obesity in fetal life. Preconception and antenatal counselling on obstetrics risk in pregnancy, on diet and lifestyle in pregnancy and on gestational weight gain is associated with a better outcome. Fetal growth velocity is closely associated with maternal weight and gestational weight gain. Careful monitoring of gestational weight gain and fetal growth, and screening and management of obstetrical complications such as gestational diabetes and pre-eclampsia, improves perinatal outcome. The use of metformin in non-diabetic obese women is under investigation; further evidence is required before recommending it.
Collapse
|
34
|
Lin CH, Chiang SL, Yates P, Lee MS, Hung YJ, Tzeng WC, Chiang LC. Moderate physical activity level as a protective factor against metabolic syndrome in middle-aged and older women. J Clin Nurs 2014; 24:1234-45. [PMID: 25257388 DOI: 10.1111/jocn.12683] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/02/2014] [Indexed: 12/17/2022]
Abstract
AIMS AND OBJECTIVES To investigate whether physical activity is a protective factor against metabolic syndrome in middle-aged and older women. BACKGROUND Socio-demographic and lifestyle behaviour factors contribute to metabolic syndrome. To minimise the risk of metabolic syndrome, several global guidelines recommend increasing physical activity level. However, only limited research has investigated the relationship between physical activity levels and metabolic syndrome in middle-aged and older women after adjusting for socio-demographic and lifestyle behaviour factors. DESIGN Cross-sectional design. METHODS A convenience sample of 326 middle-aged and older women was recruited. Metabolic syndrome was confirmed according to the National Cholesterol Education Program, Adult Treatment Panel III guidelines, and physical activity levels were measured by the International Physical Activity Questionnaire. RESULTS The sample had a mean age of 60·9 years, and the prevalence of metabolic syndrome was 43·3%. Postmenopausal women and women with low socioeconomic status (low-education background, without personal income and currently unemployed) had a significantly higher risk of developing metabolic syndrome. After adjusting for significant socio-demographic and lifestyle behaviour factors, the women with moderate or high physical activity levels had a significantly lower (OR = 0·10; OR = 0·11, p < 0·001) risk of metabolic syndrome and a lower risk for each specific component of metabolic syndrome, including elevated fasting plasma glucose (OR = 0·29; OR = 0·26, p = 0·009), elevated blood pressure (OR = 0·18; OR = 0·32, p = 0·029), elevated triglycerides (OR = 0·41; OR = 0·15, p = 0·001), reduced high-density lipoprotein (OR = 0·28; OR = 0·27, p = 0·004) and central obesity (OR = 0·31; OR = 0·22, p = 0·027). CONCLUSIONS After adjusting for socio-demographic and lifestyle behaviour factors, physical activity level was a significant protective factor against metabolic syndrome in middle-aged and older women. Higher physical activity levels (moderate or high physical activity level) reduced the risk of metabolic syndrome in middle-aged and older women. RELEVANCE TO CLINICAL PRACTICE Appropriate strategies should be developed to encourage middle-aged and older women across different socio-demographic backgrounds to engage in moderate or high levels of physical activity to reduce the risk of metabolic syndrome.
Collapse
Affiliation(s)
- Chia-Huei Lin
- Graduate Institute of Medical Sciences, School of Nursing, National Defense Medical Center, Taipei, Taiwan; Department of Nursing, Tri-Service General Hospital, Taipei, Taiwan
| | | | | | | | | | | | | |
Collapse
|
35
|
Abstract
This article discusses obesity, its contribution to clinical outcomes, and the current literature on nutrition. More than one third of Americans are obese. Literature suggests that, among critically ill patients, the relationship between obesity and outcomes is complex. Obese patients may be at greater risk of developing acute respiratory distress syndrome (ARDS) than normal weight patients. Although obesity may confer greater morbidity in intensive care, it seems to decrease mortality. ARDS is a catabolic state; patients demonstrate a profound inflammatory response, multiple organ dysfunction, and hypermetabolism, often with malnutrition. The concept of pharmaconutrition has emerged.
Collapse
Affiliation(s)
- Renee D Stapleton
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Vermont, 149 Beaumont Avenue, Burlington, VT 05405, USA.
| | - Benjamin T Suratt
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Vermont, 149 Beaumont Avenue, Burlington, VT 05405, USA
| |
Collapse
|
36
|
Kawada N, Nakanishi K, Ohama T, Nishida M, Yamauchi-Takihara K, Moriyama T. Gender differences in the relationship between blood pressure and body mass index during adolescence. Obes Res Clin Pract 2014; 9:141-51. [PMID: 25081807 DOI: 10.1016/j.orcp.2014.07.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 04/27/2014] [Accepted: 07/08/2014] [Indexed: 01/27/2023]
Abstract
OBJECTIVE In adults, gender and obesity play significant roles in the regulation of blood pressure (BP). This study investigated the effects of gender and body mass index (BMI) on BP during adolescence. DESIGN AND SETTING A cross-sectional and longitudinal study involving 6838 students under twenty years old (median, eighteen years old; male, 4624; female, 2214) at Osaka University visited the Healthcare Center for their matriculation health examination from April to May in the years 2008, 2009, and 2010, and re-visited the Healthcare Center for their student health examination from May to June in the years 2011, 2012, and 2013. METHODS Height, body weight, and BP were measured in students both on and 3 years after admission to Osaka University. RESULTS On admission, the slope of the regression line for BMI and systolic BP (SBP) in non-underweight students was significantly different between genders. SBP and diastolic BP (DBP) increased in both genders during the observation period. Among male students who had a normal BMI on admission, those who had an increase in BMI of over 4% during the observation period showed a greater increase in SBP than those who had a change in BMI of -4% to 4%. On the other hand, female students showed no change in BP with the increase in BMI. CONCLUSIONS The magnitude of BP elevation with increased BMI was associated with gender during adolescence. This may be a cause of the higher prevalence of hypertension in adult males.
Collapse
Affiliation(s)
| | | | - Tohru Ohama
- Health Care Center, Osaka University, Toyonaka, Japan
| | | | | | | |
Collapse
|
37
|
Arabin B, Stupin JH. Overweight and Obesity before, during and after Pregnancy: Part 2: Evidence-based Risk Factors and Interventions. Geburtshilfe Frauenheilkd 2014; 74:646-655. [PMID: 25100879 PMCID: PMC4119107 DOI: 10.1055/s-0034-1368462] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 04/07/2014] [Accepted: 04/10/2014] [Indexed: 12/21/2022] Open
Abstract
Overweight and obesity have become a global health problem. Obesity and excessive weight gain during pregnancy have a serious impact on maternal, fetal and neonatal outcomes. Pre-conceptional obesity and excessive weight gain during pregnancy are associated with weight gain in women following childbirth leading to associated risks such as metabolic syndrome, cardiovascular disease and diabetes. Long-term risks for the offspring are an increased risk for early cardiovascular events, metabolic syndrome and decreased life expectancy as adults. German health care has not yet adequately responded to this development. There are no clinical guidelines for obesity before, during or after pregnancy, there are no concerted actions amongst midwives, obstetricians, health advisors, politicians and the media. Research projects on effective interventions are lacking although health care concepts would be urgently needed to reduce future metabolic and cardiovascular risks for women and children as well as to minimize the associated costs for the society.
Collapse
Affiliation(s)
- B. Arabin
- Clara Angela Foundation, Witten and Berlin
- Phillips University Marburg, Centre for Mother and Child
- Department of Obstetrics, University Hospital Charité Berlin
| | - J. H. Stupin
- Clara Angela Foundation, Witten and Berlin
- Department of Obstetrics, University Hospital Charité Berlin
| |
Collapse
|
38
|
Effect of changes in BMI and waist circumference on ambulatory blood pressure in obese children and adolescents. J Hypertens 2014; 32:1470-7; discussion 1477. [DOI: 10.1097/hjh.0000000000000188] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
39
|
Ingraham N, Roberts SCM, Weitz TA. Prior Family Planning Experiences of Obese Women Seeking Abortion Care. Womens Health Issues 2014; 24:e125-30. [DOI: 10.1016/j.whi.2013.10.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Revised: 10/23/2013] [Accepted: 10/24/2013] [Indexed: 12/01/2022]
|
40
|
[Blood pressure in Germany 2008-2011: results of the German Health Interview and Examination Survey for Adults (DEGS1)]. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2013; 56:795-801. [PMID: 23703500 DOI: 10.1007/s00103-013-1669-6] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
High blood pressure is one of the most important risk factors for cardiovascular diseases and chronic kidney disease. It is a main determinant of morbidity and mortality in Germany. In the German Health Interview and Examination Survey for Adults (DEGS1) the blood pressure of 7,096 adults aged 18-79 years was measured in a standardised way using oscillometric blood pressure devices (Datascope Accutorr Plus). The average of the second and third measurements was used for analysis. The mean systolic blood pressure was 120.8 mmHg in women and 127.4 mmHg in men, while the mean diastolic blood pressure was 71.2 mmHg in women and 75.3 mmHg in men. Blood pressure values were hypertensive (systolic blood pressure ≥ 140 mmHg or diastolic blood pressure ≥ 90 mmHg) in 12.7 % of women and in 18.1 % of men. Hypertension (defined as having hypertensive blood pressure or taking antihypertensive medication in known cases of hypertension) was present in 29.9 % of women and 33.3 % of men. Almost 75 % of the survey's highest age group, 70-79, had hypertension. DEGS1 demonstrates that high blood pressure remains a highly prevalent risk factor in the population at large. The methodology employed in measuring blood pressure has been improved as compared to that of the German National Health Interview and Examination Survey 1998 (GNHIES98) and it will be possible to draw comparisons soon, once a procedure for calibrating the 1998 data has been finalised. An English full-text version of this article is available at SpringerLink as supplemental.
Collapse
|
41
|
|
42
|
Affiliation(s)
- Margaret V. Pepe
- a Department of Adult, Counseling, Health and Vocational Education , Kent State University , Kent , Ohio , 44242 , USA
- b Community Site Task Force Committee , Akron Area American Heart Association , USA
| |
Collapse
|
43
|
Mishra B, Sinha ND, Gidwani H, Shukla SK, Kawatra A, Mehta SC. Equipment errors: a prevalent cause for fallacy in blood pressure recording - a point prevalence estimate from an Indian health university. Indian J Community Med 2013; 38:15-21. [PMID: 23559698 PMCID: PMC3612291 DOI: 10.4103/0970-0218.106622] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Accepted: 06/17/2012] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Blood pressure (BP) recording is the most commonly measured clinical parameter. Standing mercury sphygmomanometer is the most widely used equipment to record this. However, recording by sphygmomanometer is subject to observer and instrumental error. The different sources of equipment error are faulty manometer tube calibration, baseline deviations and improper arm bladder cuff dimensions. This is further compounded by a high prevalence of arm bladder miss-cuffing in the target population. OBJECTIVES The study was designed to assess the presence of equipment malcalibrations, cuff miss-matching and their effect on BP recording. MATERIALS AND METHODS A cross-sectional check of all operational sphygmomanometers in a health university was carried out for the length of the manometer tube, deviation of resting mercury column from "0" level, the width and length of arm bladder cuff and extent of bladder cuff-mismatch with respect to outpatient attending population. RESULTS From the total of 50 apparatus selected, 39 (78%) were from hospital setups and 11 (22%) from pre-clinical departments. A manometer height deficit of 13 mm was recorded in 36 (92.23%) of the equipment in hospital and 11 (100%) from pre-clinical departments. Instruments from both settings showed significant deviation from recommended dimensions in cuff bladder length, width and length to width ratio (P < 0.001). Significant number of apparatus from hospital setups showed presence of mercury manometer baseline deviation either below or above 0 mmHg at the resting state (χ(2) = 5.61, D. F. = 1, P = 0.02). Positive corelationship was observed between manometer height deficit, baseline deviation and width of arm cuff bladder (Pearson correlation, P < 0.05). Bladder cuff mismatching in response to the target population was found at 48.52% for males and 36.76% for females. The cumulative effect of these factors can lead to an error in the range of 10-12 mmHg. CONCLUSION Faulty equipments and prevalent arm bladder cuff-mismatching can be important barriers to accurate BP measurement.
Collapse
Affiliation(s)
- Badrinarayan Mishra
- Department of Community Medicine, R. D. Gardi Medical College, Surasa, Ujjain, MP, India
| | - Nidhi Dinesh Sinha
- Department of Dentistry, R. D. Gardi Medical College, Surasa, Ujjain, MP, India
| | - Hitesh Gidwani
- Ex. Intern, and Asst. Prof, Pravara Institute of Medical Sciences, PMT, Loni, Maharashtra, India
| | | | - Abhishek Kawatra
- Ex. Intern, and Asst. Prof, Pravara Institute of Medical Sciences, PMT, Loni, Maharashtra, India
| | - SC Mehta
- Department of Community Medicine, R. D. Gardi Medical College, Surasa, Ujjain, MP, India
| |
Collapse
|
44
|
Kam J, Taylor DM. Obesity significantly increases the difficulty of patient management in the emergency department. Emerg Med Australas 2012; 22:316-23. [PMID: 20796008 DOI: 10.1111/j.1742-6723.2010.01307.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To determine which aspects of ED management are adversely affected by patient obesity, to determine the level of obesity above which management is made more difficult and to make recommendations on how these effects might be mitigated. METHODS This was a cross-sectional survey of patients and the staff caring for them in a single ED. Doctors, nurses and radiographers managing consecutive patients, during a range of enrolment periods, completed a self-administered questionnaire. Each was asked to record how the level of their patient's obesity increased the difficulty of specific management items, using a Likert scale. Staff also provided recommendations to mitigate the effects of obesity for each patient, if applicable. For each management item, body mass index (BMI) and management difficulty were correlated (Spearman's rank correlation). RESULTS Seven hundred and fifty patients and their ED carers were enrolled. Patient BMI was positively correlated with all aspects of ED clinical management examined (correlation coefficient range 0.28-0.57, P < 0.001). BMI most strongly correlated with difficulty in finding anatomical landmarks, venous pressure measurement, physical examination, patient positioning and procedures generally, especially cannulation and venipuncture (coefficient > 0.5, P < 0.001). Doctors reported more difficulties than nurses and radiographers. Generally, management difficulty did not increase until the BMI was in the obese or morbidly obese range. Most staff recommendations related to issues of patient mobility including equipment, staffing and bariatric devices. CONCLUSION Patient obesity significantly increases the difficulty of ED patient management. Staff recommendations to mitigate these effects were few but may inform changes in ED practice.
Collapse
Affiliation(s)
- Jeremy Kam
- Advanced Medical Science, University of Melbourne, Parkville, Victoria, Australia
| | | |
Collapse
|
45
|
Joint statement of the European Association for the Study of Obesity and the European Society of Hypertension: obesity and difficult to treat arterial hypertension. J Hypertens 2012; 30:1047-55. [PMID: 22573071 DOI: 10.1097/hjh.0b013e3283537347] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Obese patients are prone to arterial hypertension, require more antihypertensive medications, and have an increased risk of treatment-resistant arterial hypertension. Obesity-induced neurohumoral activation appears to be involved. The association between obesity and hypertension shows large inter-individual variability, likely through genetic mechanisms. Obesity affects overall cardiovascular and metabolic risk; yet, the relationship between obesity and cardiovascular risk is complex and not sufficiently addressed in clinical guidelines. The epidemiological observation that obesity may be protective in patients with established cardiovascular disease is difficult to translate into clinical experience and practice. Weight loss is often recommended as a means to lower blood pressure. However, current hypertension guidelines do not provide evidence-based guidance on how to institute weight loss. In fact, weight loss influences on blood pressure may be overestimated. Nevertheless, weight loss through bariatric surgery appears to decrease cardiovascular risk in severely obese patients. Eventually, most obese hypertensive patients will require antihypertensive medications. Data from large-scale studies with hard clinical endpoints on antihypertensive medications specifically addressing obese patients are lacking and the morbidity from the growing population of severely obese patients is poorly recognized or addressed. Because of their broad spectrum of beneficial effects, renin-angiotensin system inhibitors are considered to be the most appropriate drugs for antihypertensive treatment of obese patients. Most obese hypertensive patients require two or more antihypertensive drugs. Finally, how to combine weight loss strategies and antihypertensive treatment to achieve an optimal clinical outcome is unresolved.
Collapse
|
46
|
Logan JG, Barksdale DJ, Carlson J, Carlson BW, Rowsey PJ. Psychological stress and arterial stiffness in Korean Americans. J Psychosom Res 2012; 73:53-8. [PMID: 22691560 PMCID: PMC3374866 DOI: 10.1016/j.jpsychores.2012.04.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2012] [Revised: 04/17/2012] [Accepted: 04/18/2012] [Indexed: 01/22/2023]
Abstract
OBJECTIVE Arterial stiffness is identified as a causative factor for hypertension. The purpose of this study was to explore the relationship between psychological stress and arterial stiffness in Korean Americans. METHODS A convenience sample of 102 Korean Americans (aged 21-60 years, 60% women) was recruited from North Carolina. Psychological stress was measured by the Perceived Stress Scale, the Social, Attitudinal, Familiar, and Environmental (SAFE) Acculturative Stress Scale, and the Spielberger's State-Trait Anxiety Inventory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (cfPWV) using the SphygmoCor system (AtCor Medical, Australia). RESULTS This study shows that the emotional stress response, measured by anxiety, significantly predicted arterial stiffness (β=.25, p=.008), independently of such confounding factors as age, mean arterial pressure (MAP), gender, body mass index, smoking, education, and income. Anxiety was neither related to age (r=.12, p=.212) nor MAP (r=.14, p=.151). Additionally, this sample of Korean Americans had higher levels of psychological stress when compared to previous findings from studies of other racial/ethnic groups in the U.S. CONCLUSION Findings demonstrate that anxiety is a significant and independent determinant of arterial stiffness. Given that anxiety was not related to MAP, these findings suggest that arterial stiffness may be a pathway to explain the connection between anxiety and hypertension risk. Studies that scrutinize the relationship between anxiety and arterial stiffness are an important next step for future research. Further studies are also recommended to explore cultural factors and individual characteristics that may affect anxiety in Korean Americans.
Collapse
Affiliation(s)
- Jeongok G Logan
- School of Nursing, University of North Carolina at Chapel Hill, 105 Westside Drive, Chapel Hill, NC 27516, USA.
| | | | | | | | | |
Collapse
|
47
|
Akpolat T, Kaya C, Utaş C, Arinsoy T, Taşkapan H, Erdem E, Yilmaz ME, Ataman R, Bozfakioğlu S, Özener Ç, Karayaylali I, Kazancioğlu R, Çamsari T, Yavuz M, Ersoy F, Duman S, Ateş K. Arm circumference: its importance for dialysis patients in the obesity era. Int Urol Nephrol 2012; 45:1103-10. [PMID: 22752452 DOI: 10.1007/s11255-012-0219-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2012] [Accepted: 06/04/2012] [Indexed: 11/28/2022]
Abstract
PURPOSE The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. METHODS 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. RESULTS Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). CONCLUSIONS Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.
Collapse
Affiliation(s)
- Tekin Akpolat
- Department of Nephrology, Ondokuz Mayis University School of Medicine, Samsun, 55139, Turkey.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
The global pandemic of maternal obesity presents a major challenge for healthcare providers, and has significant short- and long-term implications for both maternal and fetal health. Currently, the evidence-base underpinning many of the interventions either currently in use or recommended to improve pregnancy outcome in obese women is limited. The nature and timing of these interventions vary widely, ranging from simple advice to more intensive dietary and exercise programmes, cognitive behavioural therapy and drug trials. In addition, a growing number of very severely obese women now enter pregnancy having had surgical interventions. Although surgical interventions such as gastric bypass or banding may be associated with improved pregnancy outcomes, these women have particular nutritional requirements, which need to be addressed to optimise pregnancy outcome. Until the outcomes of ongoing current trials are reported and provide a firm evidence base on which to base future intervention strategies and guide evidence based care for obese pregnant women, pregnancy outcome is best optimised by high-risk antenatal care delivered by healthcare providers who are experienced in supporting these high-risk women.
Collapse
|
49
|
Martino JL, Stapleton RD, Wang M, Day AG, Cahill NE, Dixon AE, Suratt BT, Heyland DK. Extreme obesity and outcomes in critically ill patients. Chest 2011; 140:1198-1206. [PMID: 21816911 DOI: 10.1378/chest.10-3023] [Citation(s) in RCA: 108] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Recent literature suggests that obese critically ill patients do not have worse outcomes than patients who are normal weight. However, outcomes in extreme obesity (BMI ≥ 40 kg/m(2)) are unclear. We sought to determine the association between extreme obesity and ICU outcomes. METHODS We analyzed data from a multicenter international observational study of ICU nutrition practices that occurred in 355 ICUs in 33 countries from 2007 to 2009. Included patients were mechanically ventilated adults ≥ 18 years old who remained in the ICU for > 72 h. Using generalized estimating equations and Cox proportional hazard modeling with clustering by ICU and adjusting for potential confounders, we compared extremely obese to normal-weight patients in terms of duration of mechanical ventilation (DMV), ICU length of stay (LOS), hospital LOS, and 60-day mortality. RESULTS Of the 8,813 patients included in this analysis, 3,490 were normal weight (BMI 18.5-24.9 kg/m(2)), 348 had BMI 40 to 49.9 kg/m(2), 118 had BMI 50 to 59.9 kg/m(2), and 58 had BMI ≥ 60 kg/m(2). Unadjusted analyses suggested that extremely obese critically ill patients have improved mortality (OR for death, 0.77; 95% CI, 0.62-0.94), but this association was not significant after adjustment for confounders. However, an adjusted analysis of survivors found that extremely obese patients have a longer DMV and ICU LOS, with the most obese patients (BMI ≥ 60 kg/m(2)) also having longer hospital LOS. CONCLUSIONS During critical illness, extreme obesity is not associated with a worse survival advantage compared with normal weight. However, among survivors, BMI ≥ 40 kg/m(2) is associated with longer time on mechanical ventilation and in the ICU. These results may have prognostic implications for extremely obese critically ill patients.
Collapse
Affiliation(s)
- Jenny L Martino
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Vermont, Burlington, VT
| | - Renee D Stapleton
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Vermont, Burlington, VT.
| | - Miao Wang
- Clinical Evaluation Research Unit, Kingston General Hospital, Kingston, ON, Canada
| | - Andrew G Day
- Clinical Evaluation Research Unit, Kingston General Hospital, Kingston, ON, Canada; Department of Community Health and Epidemiology, Queen's University, Kingston, ON, Canada
| | - Naomi E Cahill
- Clinical Evaluation Research Unit, Kingston General Hospital, Kingston, ON, Canada; Department of Community Health and Epidemiology, Queen's University, Kingston, ON, Canada
| | - Anne E Dixon
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Vermont, Burlington, VT
| | - Benjamin T Suratt
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, University of Vermont, Burlington, VT
| | - Daren K Heyland
- Clinical Evaluation Research Unit, Kingston General Hospital, Kingston, ON, Canada; Department of Community Health and Epidemiology, Queen's University, Kingston, ON, Canada; Department of Medicine, Queen's University, Kingston, ON, Canada
| |
Collapse
|
50
|
Baxi V, Budhakar S. Anesthesia management of a morbidly obese patient in prone position for lumbar spine surgery. JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE 2011; 1:55-7. [PMID: 20890416 PMCID: PMC2944860 DOI: 10.4103/0974-8237.65483] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
A morbidly obese, 45-year-old woman with a body mass index of 47 kg/m2 , presented with a prolapsed intervertebral disc of the lumbar spine for decompression and fixation. Anesthesia and surgical positioning of morbidly obese patient carries 3 main hazards, namely, morbid obesity, prone position, and airway preservation problems. Morbid obesity has its own hazards of deep vein thrombosis and pulmonary embolus. Here we describe anesthetic management, successfully dealing with the specific problems of this patient due to obesity.
Collapse
Affiliation(s)
- Vaibhavi Baxi
- Lilavati Hospital and Research Centre, Mumbai, India
| | | |
Collapse
|