1
|
Gopal N, Chauhan N, Jain U, Dass SK, Kumar S, Chandra R. Designing of a unique bioreceptor and fabrication of an efficient genosensing platform for neonatal sepsis detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4066-4076. [PMID: 37551420 DOI: 10.1039/d3ay00567d] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
We report the results of studies related to the fabrication of a nanostructured graphene oxide (GO)-based electrochemical genosensor for neonatal sepsis detection. Initially, we selected the fimA gene of E. coli for nenonatal sepsis detection and further designed a 20-mer long amine-terminated oligonucleotide. This designed oligonucleotide will work as a bioreceptor for the detection of the virulent fimA gene. An electrochemical genosensor was further developed where GO was used as an immobilization matrix. For the formation of a thin film of GO on an indium tin oxide (ITO)-coated glass electrode, an optimized DC potential of 10 V for 90 s was applied via an electrophoretic deposition unit. Thereafter, the designed oligonucleotides were immobilized through EDC-NHS chemistry. The nanomaterial and fabricated electrodes were characterized via X-ray diffraction, scanning electron microscopy, Fourier transform infrared spectroscopy and cyclic voltammetry techniques. The fabricated genosensor (BSA/pDNA/GO/ITO) has the ability to detect the target fimA gene with a linear detection range of 10-12 M to 10-6 M, a lower detection limit of 10-12 M and a sensitivity of 114.7 μA M-1 cm-2. We also investigated the biosensing ability of the developed genosensor in an artificial serum sample and the obtained electrochemical results were within the acceptable percentage relative standard deviation (% RSD), indicating that the fabricated genosensor can be used for the detection of neonatal sepsis by using a serum sample.
Collapse
Affiliation(s)
- Neha Gopal
- Drug Discovery and Development Laboratory, Department of Chemistry, University of Delhi, Delhi-110007, India.
| | - Nidhi Chauhan
- School of Health Sciences and Technology, UPES, Dehradun 248007, Uttarakhand, India
| | - Utkarsh Jain
- School of Health Sciences and Technology, UPES, Dehradun 248007, Uttarakhand, India
| | - Sujata K Dass
- Department of Neurology, BLK Super Speciality Hospital, New Delhi-110005, India
| | - Suveen Kumar
- Drug Discovery and Development Laboratory, Department of Chemistry, University of Delhi, Delhi-110007, India.
| | - Ramesh Chandra
- Drug Discovery and Development Laboratory, Department of Chemistry, University of Delhi, Delhi-110007, India.
- Institute of Nano Medical Sciences, University of Delhi, Delhi-110007, India
- Dr. B. R. Ambedkar Center for Biomedical Research, University of Delhi, Delhi-110007, India
- Maharaja Surajmal Brij University, Bharatpur, Rajasthan-321201, India
| |
Collapse
|
2
|
Robin P, Gerber-Lemaire S. Design and Preparation of Sensing Surfaces for Capacitive Biodetection. BIOSENSORS 2022; 13:17. [PMID: 36671852 PMCID: PMC9856139 DOI: 10.3390/bios13010017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/15/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Despite their high sensitivity and their suitability for miniaturization, biosensors are still limited for clinical applications due to the lack of reproducibility and specificity of their detection performance. The design and preparation of sensing surfaces are suspected to be a cause of these limitations. Here, we first present an updated overview of the current state of use of capacitive biosensors in a medical context. Then, we summarize the encountered strategies for the fabrication of capacitive biosensing surfaces. Finally, we describe the characteristics which govern the performance of the sensing surfaces, along with recent developments that were suggested to overcome their main current limitations.
Collapse
|
3
|
Park JH, Song Z, Bong JH, Kim HR, Kim MJ, Choi KH, Shin SS, Kang MJ, Lee DY, Pyun JC. Electrochemical One-Step Immunoassay Based on Switching Peptides and Pyrolyzed Carbon Electrodes. ACS Sens 2022; 7:215-224. [PMID: 34984905 DOI: 10.1021/acssensors.1c01998] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Switching peptides were designed to bind reversibly to the binding pocket of antibodies (IgG) by interacting with frame regions (FRs). These peptides can be quantitatively released when antigens bind to IgG. As FRs have conserved amino acid sequences, switching peptides can be used as antibodies for different antigens and different source animals. In this study, an electrochemical one-step immunoassay was conducted using switching peptides labeled with ferrocene for the quantitative measurement of analytes. For the effective amperometry of the switching peptides labeled with ferrocene, a pyrolyzed carbon electrode was prepared by pyrolysis of the parylene-C film. The feasibility of the pyrolyzed carbon electrode for the electrochemical one-step immunoassay was determined by analyzing its electrochemical properties, such as its low double-layer capacitance (Cdl), high electron transfer rate (kapp), and wide electrochemical window. In addition, the factors influencing the amperometry of switching peptides labeled with ferrocene were analyzed according to the hydrodynamic radius, the number of intrahydrogen bonds, dipole moments, and diffusion coefficients. Finally, the applicability of the electrochemical one-step immunoassay for the medical diagnosis of the human hepatitis B surface antigen (hHBsAg) was assessed.
Collapse
Affiliation(s)
- Jun-Hee Park
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Zhiquan Song
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Ji-Hong Bong
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Hong-Rae Kim
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Moon-Ju Kim
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| | - Kyung-Hak Choi
- OPTOLANE Technologies Inc., 20 Pangyoyeok-ro 241beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13494, Republic of Korea
| | - Seung-Shick Shin
- OPTOLANE Technologies Inc., 20 Pangyoyeok-ro 241beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13494, Republic of Korea
| | - Min-Jung Kang
- Korea Institute of Science and Technology (KIST), 5 Hwarang-ro 14-gil, Seongbuk-gu, Seoul 02792, Republic of Korea
| | - Do Young Lee
- OPTOLANE Technologies Inc., 20 Pangyoyeok-ro 241beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13494, Republic of Korea
| | - Jae-Chul Pyun
- Department of Materials Science and Engineering, Yonsei University, 50 Yonsei-Ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| |
Collapse
|
4
|
Zhang C, Shi D, Li X, Yuan J. Microfluidic electrochemical magnetoimmunosensor for ultrasensitive detection of interleukin-6 based on hybrid of AuNPs and graphene. Talanta 2021; 240:123173. [PMID: 34999320 DOI: 10.1016/j.talanta.2021.123173] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 11/04/2021] [Accepted: 12/22/2021] [Indexed: 02/02/2023]
Abstract
Cytokines are important factors in the early diagnosis of autoimmune diseases and require high sensitivity, high selectivity and quantitative detection. We proposed a miniaturized electrochemical magneto-immunosensor (EC-MIS) on portable interleukin-6 (IL-6) detection based on this requirement. Firstly, a micro-fabricated working electrode is electrochemically modified with a hybrid of reduced graphene oxide (rGO) and gold nanoparticles (AuNPs). Increased surface area and enhanced charge transfer rate improve the performance of this immunosensor on sensitivity. Secondly, magnetic beads attached with the capture antibody (cAb) are employed in sandwich immunoassay. This kind of immunoassay is immobilized on the working electrode surface by an external magnet to enrich the analyte IL-6. Thirdly, the last two features are combined and integrated on a microfluidic device in order to restrict the sample at certain areas and ease the operation of detection. With our prototypic EC-MIS operated in amperometric mode, we have achieved the detection of IL-6 with a linear range from 0.97 to 250 pg/mL and a limit of detection (LOD) of 0.42 pg/mL. Real serum samples were demonstrated and compared with benchtop equipment's results.
Collapse
Affiliation(s)
- Chiye Zhang
- Department of Electronic & Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong.
| | - Dongmin Shi
- Microelectronics, The Hong Kong University of Science and Technology (GZ), Hong Kong
| | - Xiaoyuan Li
- Department of Chemistry, The Hong Kong University of Science and Technology, Hong Kong
| | - Jie Yuan
- Department of Electronic & Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong
| |
Collapse
|
5
|
Dutta N, Lillehoj PB, Estrela P, Dutta G. Electrochemical Biosensors for Cytokine Profiling: Recent Advancements and Possibilities in the Near Future. BIOSENSORS 2021; 11:94. [PMID: 33806879 PMCID: PMC8004910 DOI: 10.3390/bios11030094] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 03/14/2021] [Accepted: 03/18/2021] [Indexed: 02/07/2023]
Abstract
Cytokines are soluble proteins secreted by immune cells that act as molecular messengers relaying instructions and mediating various functions performed by the cellular counterparts of the immune system, by means of a synchronized cascade of signaling pathways. Aberrant expression of cytokines can be indicative of anomalous behavior of the immunoregulatory system, as seen in various illnesses and conditions, such as cancer, autoimmunity, neurodegeneration and other physiological disorders. Cancer and autoimmune diseases are particularly adept at developing mechanisms to escape and modulate the immune system checkpoints, reflected by an altered cytokine profile. Cytokine profiling can provide valuable information for diagnosing such diseases and monitoring their progression, as well as assessing the efficacy of immunotherapeutic regiments. Toward this goal, there has been immense interest in the development of ultrasensitive quantitative detection techniques for cytokines, which involves technologies from various scientific disciplines, such as immunology, electrochemistry, photometry, nanotechnology and electronics. This review focusses on one aspect of this collective effort: electrochemical biosensors. Among the various types of biosensors available, electrochemical biosensors are one of the most reliable, user-friendly, easy to manufacture, cost-effective and versatile technologies that can yield results within a short period of time, making it extremely promising for routine clinical testing.
Collapse
Affiliation(s)
- Nirmita Dutta
- School of Medical Science and Technology (SMST), Indian Institute of Technology Kharagpur, Kharagpur 721302, India;
| | - Peter B. Lillehoj
- Department of Mechanical Engineering, Rice University, Houston, TX 77005, USA;
| | - Pedro Estrela
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio) and Department of Electronic & Electrical Engineering, University of Bath, Bath BA2 7AY, UK
| | - Gorachand Dutta
- School of Medical Science and Technology (SMST), Indian Institute of Technology Kharagpur, Kharagpur 721302, India;
| |
Collapse
|
6
|
Latest developments in non-faradic impedimetric biosensors: Towards clinical applications. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116073] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Arkusz K, Paradowska E. Impedimetric Detection of Femtomolar Levels of Interleukin6, Interleukin 8, and Tumor Necrosis Factor Alpha Based on Thermally Modified Nanotubular Titanium Dioxide Arrays. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2399. [PMID: 33266223 PMCID: PMC7760759 DOI: 10.3390/nano10122399] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 11/23/2020] [Accepted: 11/30/2020] [Indexed: 01/07/2023]
Abstract
An inexpensive, easy to prepare, and label-free electrochemical impedance spectroscopy-based biosensor has been developed for the selective detection of human interleukin 6 (IL-6), interleukin 8 (CXCL8, IL-8), and tumor necrosis factor (TNFα)-potential inflammatory cancer biomarkers. We describe a, so far, newly developed and unexplored method to immobilize antibodies onto a titanium dioxide nanotube (TNT) array by physical adsorption. Immobilization of anti-IL-6, anti-IL-8, and anti-TNFα on TNT and the detection of human IL-6, IL-8, and TNFα were examined using electrochemical impedance spectroscopy (EIS). The impedimetric immunosensor demonstrates good selectivity and high sensitivity against human biomarker analytes and can detect IL-6, IL-8, and TNFα at concentrations as low as 5 pg/mL, equivalent to the standard concentration of these proteins in human blood. The calibration curves evidenced that elaborated biosensors are sensitive to three cytokines within 5 ÷ 2500 pg/mL in the 0.01 M phosphate-buffered saline solution (pH 7.4).
Collapse
Affiliation(s)
- Katarzyna Arkusz
- Department of Biomedical Engineering, Faculty of Mechanical Engineering, University of Zielona Gora, Licealna 9 Street, 65-417 Zielona Gora, Poland;
| | | |
Collapse
|
8
|
Balayan S, Chauhan N, Chandra R, Kuchhal NK, Jain U. Recent advances in developing biosensing based platforms for neonatal sepsis. Biosens Bioelectron 2020; 169:112552. [PMID: 32931992 DOI: 10.1016/j.bios.2020.112552] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 08/16/2020] [Accepted: 08/23/2020] [Indexed: 12/12/2022]
Abstract
Neonatal sepsis is a bloodstream infection primarily caused by Escherichia coli (E. coli), Group B Streptococcus (GBS), Listeria monocytogenes, Haemophilus influenzae, S. aureus, Klebsiella spp. and non-typhoidal Salmonella bacteria. Neonatal Sepsis is referred as a critical response to the infection in the neonatal period that can lead to the failure of body organs and thereby causing damage to the tissues resulting in death of the neonates. Nearly 4 million deaths across the world are occurred due to neonatal sepsis infections. In order to prevent the bloodstream infections in the neonates, it is indispensable to diagnose the disease properly for appropriate treatment during the point of care. Numerous studies have been reported to identify major biomarkers associated with neonatal sepsis including Serum Amyloid A (SAA), C - reactive protein (CRP), Procalcitonin (PCT) and Lipopolysaccharide-binding protein (LBP). Distinct diagnostic platforms have also been developed detecting the presence of bloodstream infections including electrochemical, potentiometric, and impedimetric sensors. Recently, electrochemical biosensors with the integration of nanomaterials have emerged as a better platform for neonatal sepsis biomarkers detection. This review article summarizes the diverse screening platforms, evaluation parameters, and new advances based on implications of nanomaterials for the development of biosensors detecting neonatal sepsis infections. The review further elucidates the significance and future scope of distinctive platforms which are predominantly associated with detection of neonatal sepsis.
Collapse
Affiliation(s)
- Sapna Balayan
- Amity Institute of Nanotechnology, Amity University, Noida, 201313, Uttar Pradesh, India
| | - Nidhi Chauhan
- Amity Institute of Nanotechnology, Amity University, Noida, 201313, Uttar Pradesh, India
| | - Ramesh Chandra
- Department of Chemistry, University of Delhi, Delhi, 110007, India
| | | | - Utkarsh Jain
- Amity Institute of Nanotechnology, Amity University, Noida, 201313, Uttar Pradesh, India.
| |
Collapse
|
9
|
Zhang J, Jin R, Jiang D, Chen HY. Electrochemiluminescence-Based Capacitance Microscopy for Label-Free Imaging of Antigens on the Cellular Plasma Membrane. J Am Chem Soc 2019; 141:10294-10299. [PMID: 31180678 DOI: 10.1021/jacs.9b03007] [Citation(s) in RCA: 154] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Electrochemiluminescence (ECL)-based capacitance microscopy using a square-wave voltage is established unprecedentedly to realize the label-free visualization of species on electrode surfaces and cellular plasma membranes. The drop in the local capacitance upon the binding of species to the surface or to a cellular membrane is derived to induce a relatively larger potential drop ( Vdl) across the double layer on the local electrode surface, which is utilized to prompt enhanced ECL at the binding position. The square-wave voltage with a frequency of as high as 1.5 kHz is proven to be favorable for the discrimination of the local ECL from the surrounding signal. Using this new detection principle and resultant capacitance microscopy, carcinoembryonic antigens (CEA) at amounts of as low as 1 pg can be visualized. Further application of this approach permits the direct imaging of CEA antigens on single MCF-7 cells through the capacitance change after the formation of the antigen-antibody complex. Successful visualization of the analyte without any ECL tag will allow not only special capacitance microscopy for label-free bioassays but also a novel ECL detection approach for the sensitive detection of biomolecules.
Collapse
Affiliation(s)
- Jingjing Zhang
- State Key Laboratory of Analytical Chemistry for Life and School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China.,School of Pharmacy , Nanjing Medical University , Nanjing , Jiangsu 211126 , P. R. China
| | - Rong Jin
- State Key Laboratory of Analytical Chemistry for Life and School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Dechen Jiang
- State Key Laboratory of Analytical Chemistry for Life and School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Hong-Yuan Chen
- State Key Laboratory of Analytical Chemistry for Life and School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| |
Collapse
|
10
|
Ghosh Dastider S, Abdullah A, Jasim I, Yuksek NS, Dweik M, Almasri M. Low concentration E. coli O157:H7 bacteria sensing using microfluidic MEMS biosensor. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:125009. [PMID: 30599553 DOI: 10.1063/1.5043424] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
This paper reports the design, fabrication, and testing of a microfluidic MEMS biosensor for rapid sensing of low concentration Escherichia coli O157:H7. It consists of a specially designed focusing and sensing region, which enables the biosensor to detect low concentration of bacterial cells. The focusing region consists of a ramped vertical electrode pair made of electroplated gold along with tilted thin film finger pairs (45°) embedded inside a microchannel. The focusing region generates positive dielectrophoresis force, which moves the cells towards the edges of the tilted thin film electrode fingers, located at the center of the microchannel. The fluidic drag force then carries the focused cells to the sensing region, where three interdigitated electrode arrays (IDEAs) with 30, 20, and 10 pairs, respectively, are embedded inside the microchannel. This technique resulted in highly concentrated samples in the sensing region. The sensing IDEAs are functionalized with the anti-E. coli antibody for specific sensing of E. coli 0157:H7. As E. coli binds to the antibody, it results in an impedance change, which is measured across a wide frequency range of 100 Hz-10 MHz. The biosensor was fabricated on a glass substrate using the SU8 epoxy resist to form the microchannel, gold electroplating to form the vertical focusing electrode pair, a thin gold film to form the sensing electrode, the finger electrodes, traces and bonding pads, and polydimethylsiloxane to seal the device. The microfluidic impedance biosensor was tested with various low concentration bacterial samples and was able to detect bacterial concentration, as low as 39 CFU/ml with a total sensing time of 2 h.
Collapse
Affiliation(s)
- Shibajyoti Ghosh Dastider
- Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211, USA
| | - Amjed Abdullah
- Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211, USA
| | - Ibrahem Jasim
- Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211, USA
| | - Nuh S Yuksek
- Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211, USA
| | - Majed Dweik
- Department of Co-operative Research, Lincoln University, Jefferson City, Missouri 65101, USA
| | - Mahmoud Almasri
- Department of Electrical and Computer Engineering, University of Missouri, Columbia, Missouri 65211, USA
| |
Collapse
|
11
|
Alizadeh Zeinabad H, Ghourchian H, Falahati M, Fathipour M, Azizi M, Boutorabi SM. Ultrasensitive interdigitated capacitance immunosensor using gold nanoparticles. NANOTECHNOLOGY 2018; 29:265102. [PMID: 29629877 DOI: 10.1088/1361-6528/aabca3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Immunosensors based on interdigitated electrodes (IDEs), have recently demonstrated significant improvements in the sensitivity of capacitance detection. Herein, a novel type of highly sensitive, compact and portable immunosensor based on a gold interdigital capacitor has been designed and developed for the rapid detection of hepatitis B surface antigen (HBsAg). To improve the efficiency of antibody immobilization and time-saving, a self-assembled monolayer (SAM) of 2-mercaptoethylamine film was coated on IDEs. Afterwards, carboxyl groups on primary antibodies were activated through 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and were immobilized on amino-terminated SAM for better control of the oriented immobilization of antibodies on gold IDEs. In addition, gold nanoparticles conjugated with a secondary antibody were used to enhance the sensitivity. Under optimal conditions, the immunosensor exhibited the sensitivity of 0.22 nF.pg ml-1, the linear range from 5 pg ml-1 to 1 ng ml-1 and the detection limit of 1.34 pg ml-1, at a signal-to-noise ratio of 3.
Collapse
Affiliation(s)
- Hojjat Alizadeh Zeinabad
- Laboratory of Bioanalysis, Institute of Biochemistry and Biophysics, University of Tehran, Tehran, Iran. MEMS & NEMS Lab, Department of Electrical and Computer Engineering, University of Tehran, Tehran, Iran. Department of Nanotechnology, Faculty of Advance Science and Technology, Pharmaceutical Sciences Branch, Islamic Azad University, Tehran, Iran
| | | | | | | | | | | |
Collapse
|
12
|
Li M, Liu S, Jiang Y, Wang W. Visualizing the Zero-Potential Line of Bipolar Electrodes with Arbitrary Geometry. Anal Chem 2018; 90:6390-6396. [DOI: 10.1021/acs.analchem.7b04881] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Meng Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Shasha Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Yingyan Jiang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Wei Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
13
|
Gentili D, D’Angelo P, Militano F, Mazzei R, Poerio T, Brucale M, Tarabella G, Bonetti S, Marasso SL, Cocuzza M, Giorno L, Iannotta S, Cavallini M. Integration of organic electrochemical transistors and immuno-affinity membranes for label-free detection of interleukin-6 in the physiological concentration range through antibody–antigen recognition. J Mater Chem B 2018; 6:5400-5406. [DOI: 10.1039/c8tb01697f] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A label-free immunosensor based on an organic electrochemical transistor integrated with an immuno-affinity membrane for cytokine detection at physiologically relevant concentrations is reported.
Collapse
|
14
|
Abstract
DNA biosensors could overcome some of the common drawbacks of lab-based techniques for nucleic acids detection for diagnostics purposes. One of the main impediments for such applications of DNA biosensors is their lack of sensitivity: this can prevent their full exploitation in the diagnostic analytical field. DNA nanotechnology could enhance DNA biosensors and let them perform at the required high sensitivity. Well-designed, programmable self-assembly reactions can be triggered by a specific nucleic acid target. The Hybridization Chain Reaction (HCR) is a self-assembly strategy in which the target nucleic acid sequence triggers the formation of long nicked double-stranded DNA nanostructures. This can be performed in solution or on a surface, and the process can be coupled to different signal transduction schemes. We here describe the methods to design and test HCR reactions for the detection of different nucleic acid targets in solution and the procedures to exploit this strategy on surfaces with an electrochemical biosensing platform.
Collapse
Affiliation(s)
- Andrea Miti
- Department of Pharmacy and Biotechnology, University of Bologna, Bologna, Italy
| | - Giampaolo Zuccheri
- Department of Pharmacy and Biotechnology, University of Bologna, Bologna, Italy.
| |
Collapse
|
15
|
Alhoshany A, Sivashankar S, Mashraei Y, Omran H, Salama KN. A Biosensor-CMOS Platform and Integrated Readout Circuit in 0.18-μm CMOS Technology for Cancer Biomarker Detection. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1942. [PMID: 28832523 PMCID: PMC5620726 DOI: 10.3390/s17091942] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 08/20/2017] [Accepted: 08/21/2017] [Indexed: 11/16/2022]
Abstract
This paper presents a biosensor-CMOS platform for measuring the capacitive coupling of biorecognition elements. The biosensor is designed, fabricated, and tested for the detection and quantification of a protein that reveals the presence of early-stage cancer. For the first time, the spermidine/spermine N1 acetyltransferase (SSAT) enzyme has been screened and quantified on the surface of a capacitive sensor. The sensor surface is treated to immobilize antibodies, and the baseline capacitance of the biosensor is reduced by connecting an array of capacitors in series for fixed exposure area to the analyte. A large sensing area with small baseline capacitance is implemented to achieve a high sensitivity to SSAT enzyme concentrations. The sensed capacitance value is digitized by using a 12-bit highly digital successive-approximation capacitance-to-digital converter that is implemented in a 0.18 μm CMOS technology. The readout circuit operates in the near-subthreshold regime and provides power and area efficient operation. The capacitance range is 16.137 pF with a 4.5 fF absolute resolution, which adequately covers the concentrations of 10 mg/L, 5 mg/L, 2.5 mg/L, and 1.25 mg/L of the SSAT enzyme. The concentrations were selected as a pilot study, and the platform was shown to demonstrate high sensitivity for SSAT enzymes on the surface of the capacitive sensor. The tested prototype demonstrated 42.5 μS of measurement time and a total power consumption of 2.1 μW.
Collapse
Affiliation(s)
- Abdulaziz Alhoshany
- Computer, Electrical and Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia.
| | - Shilpa Sivashankar
- Department of Biomedical Engineering, University of Chapel Hill/North Carolina State University, Raleigh, NC 27695, USA.
| | - Yousof Mashraei
- Computer, Electrical and Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia.
| | - Hesham Omran
- The Integrated Circuits Lab, Faculty of Engineering, Ain Shams University, Cairo 11535, Egypt.
| | - Khaled N Salama
- Computer, Electrical and Mathematical Science and Engineering Division (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia.
| |
Collapse
|
16
|
Capacitive Biosensors and Molecularly Imprinted Electrodes. SENSORS 2017; 17:s17020390. [PMID: 28218689 PMCID: PMC5336051 DOI: 10.3390/s17020390] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Revised: 01/16/2017] [Accepted: 02/08/2017] [Indexed: 01/05/2023]
Abstract
Capacitive biosensors belong to the group of affinity biosensors that operate by registering direct binding between the sensor surface and the target molecule. This type of biosensors measures the changes in dielectric properties and/or thickness of the dielectric layer at the electrolyte/electrode interface. Capacitive biosensors have so far been successfully used for detection of proteins, nucleotides, heavy metals, saccharides, small organic molecules and microbial cells. In recent years, the microcontact imprinting method has been used to create very sensitive and selective biorecognition cavities on surfaces of capacitive electrodes. This chapter summarizes the principle and different applications of capacitive biosensors with an emphasis on microcontact imprinting method with its recent capacitive biosensor applications.
Collapse
|
17
|
Biomimetic nanochannels based biosensor for ultrasensitive and label-free detection of nucleic acids. Biosens Bioelectron 2016; 86:194-201. [DOI: 10.1016/j.bios.2016.06.059] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 06/07/2016] [Accepted: 06/19/2016] [Indexed: 11/18/2022]
|
18
|
Sharma R, Deacon SE, Nowak D, George SE, Szymonik MP, Tang AAS, Tomlinson DC, Davies AG, McPherson MJ, Wälti C. Label-free electrochemical impedance biosensor to detect human interleukin-8 in serum with sub-pg/ml sensitivity. Biosens Bioelectron 2016; 80:607-613. [PMID: 26897263 PMCID: PMC4785862 DOI: 10.1016/j.bios.2016.02.028] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Revised: 02/08/2016] [Accepted: 02/10/2016] [Indexed: 01/01/2023]
Abstract
Biosensors with high sensitivity and short time-to-result that are capable of detecting biomarkers in body fluids such as serum are an important prerequisite for early diagnostics in modern healthcare provision. Here, we report the development of an electrochemical impedance-based sensor for the detection in serum of human interleukin-8 (IL-8), a pro-angiogenic chemokine implicated in a wide range of inflammatory diseases. The sensor employs a small and robust synthetic non-antibody capture protein based on a cystatin scaffold that displays high affinity for human IL-8 with a KD of 35±10 nM and excellent ligand specificity. The change in the phase of the electrochemical impedance from the serum baseline, ∆θ(ƒ), measured at 0.1 Hz, was used as the measure for quantifying IL-8 concentration in the fluid. Optimal sensor signal was observed after 15 min incubation, and the sensor exhibited a linear response versus logarithm of IL-8 concentration from 900 fg/ml to 900 ng/ml. A detection limit of around 90 fg/ml, which is significantly lower than the basal clinical levels of 5–10 pg/ml, was observed. Our results are significant for the development of point-of-care and early diagnostics where high sensitivity and short time-to-results are essential. A label-free electrochemical impedance-based sensor for the detection of human interleukin-8 (IL-8) in full serum was developed. Detection limit of 90 fg/ml and time-to-result of 15 min was found. A large dynamic range of the sensor was observed, with sensor response linear vs logarithm of IL-8 concentration from 900 fg/ml to 900 ng/ml. The sensor employs a small and robust synthetic non-antibody capture protein, with high stability and excellent ligand specificity. Findings are particularly relevant for the development of point-of-care and early diagnosis sensors where high sensitivity and short time-to-results are essential.
Collapse
Affiliation(s)
- R Sharma
- School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - S E Deacon
- School of Molecular and Cellular Biology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - D Nowak
- School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - S E George
- School of Molecular and Cellular Biology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - M P Szymonik
- School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - A A S Tang
- School of Molecular and Cellular Biology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; BioScreening Technology Group, Astbury Building, University of Leeds, Leeds LS2 9JT, UK
| | - D C Tomlinson
- School of Molecular and Cellular Biology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; BioScreening Technology Group, Astbury Building, University of Leeds, Leeds LS2 9JT, UK
| | - A G Davies
- School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - M J McPherson
- School of Molecular and Cellular Biology, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; BioScreening Technology Group, Astbury Building, University of Leeds, Leeds LS2 9JT, UK.
| | - C Wälti
- School of Electronic and Electrical Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
| |
Collapse
|
19
|
Liu JT, Settu K, Tsai JZ, Chen CJ. Impedance sensor for rapid enumeration of E. coli in milk samples. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.09.029] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
20
|
Huang X, Deng H, Fang Y, Wang L. Role of Introduction of a Resistor in Series with the Working Electrode in Impedance Related Electrochemical Measurements. ELECTROANAL 2015. [DOI: 10.1002/elan.201500170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
21
|
A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7. Biomed Microdevices 2015; 17:5. [DOI: 10.1007/s10544-014-9925-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
22
|
Stenken JA, Poschenrieder AJ. Bioanalytical chemistry of cytokines--a review. Anal Chim Acta 2015; 853:95-115. [PMID: 25467452 PMCID: PMC4717841 DOI: 10.1016/j.aca.2014.10.009] [Citation(s) in RCA: 202] [Impact Index Per Article: 20.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 09/30/2014] [Accepted: 10/08/2014] [Indexed: 02/06/2023]
Abstract
Cytokines are bioactive proteins produced by many different cells of the immune system. Due to their role in different inflammatory disease states and maintaining homeostasis, there is enormous clinical interest in the quantitation of cytokines. The typical standard methods for quantitation of cytokines are immunoassay-based techniques including enzyme-linked immusorbent assays (ELISA) and bead-based immunoassays read by either standard or modified flow cytometers. A review of recent developments in analytical methods for measurements of cytokine proteins is provided. This review briefly covers cytokine biology and the analysis challenges associated with measurement of these biomarker proteins for understanding both health and disease. New techniques applied to immunoassay-based assays are presented along with the uses of aptamers, electrochemistry, mass spectrometry, optical resonator-based methods. Methods used for elucidating the release of cytokines from single cells as well as in vivo collection methods are described.
Collapse
Affiliation(s)
- Julie A Stenken
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Andreas J Poschenrieder
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR 72701, USA; Pharmaceutical Radiochemistry, Technische Universität München, Walther-Meißner-Street 3, D-85748 Garching, Germany
| |
Collapse
|
23
|
Mihailescu CM, Stan D, Iosub R, Moldovan C, Savin M. A Sensitive capacitive immunosensor for direct detection of human heart fatty acid-binding protein (h-FABP). Talanta 2015; 132:37-43. [DOI: 10.1016/j.talanta.2014.08.067] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 08/20/2014] [Accepted: 08/28/2014] [Indexed: 11/28/2022]
|
24
|
Patil AV, Bedatty Fernandes FC, Bueno PR, Davis JJ. Immittance Electroanalysis in Diagnostics. Anal Chem 2014; 87:944-50. [DOI: 10.1021/ac503156a] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Amol V. Patil
- Department
of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Flávio C. Bedatty Fernandes
- Institute
of Chemistry, Physical Chemistry Department, Univ. Estadual Paulista (São Paulo State University), Nanobionics Research Group, CP 355, 14800-900, Araraquara, São
Paulo, Brazil
| | - Paulo R. Bueno
- Institute
of Chemistry, Physical Chemistry Department, Univ. Estadual Paulista (São Paulo State University), Nanobionics Research Group, CP 355, 14800-900, Araraquara, São
Paulo, Brazil
| | - Jason J. Davis
- Department
of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| |
Collapse
|
25
|
Chaocharoen W, Suginta W, Limbut W, Ranok A, Numnuam A, Khunkaewla P, Kanatharana P, Thavarungkul P, Schulte A. Electrochemical detection of the disease marker human chitinase-3-like protein 1 by matching antibody-modified gold electrodes as label-free immunosensors. Bioelectrochemistry 2014; 101:106-13. [PMID: 25203453 DOI: 10.1016/j.bioelechem.2014.07.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Revised: 06/27/2014] [Accepted: 07/06/2014] [Indexed: 01/27/2023]
Abstract
Tissue inflammation, certain cardiovascular syndromes and the occurrence of some solid tumors are correlated with raised serum concentrations of human chitinase-3-like protein 1 (YKL-40), a mammalian chitinase-like glycoprotein, which has become the subject of current research. Here we report the construction and characterization of an electrochemical platform for label-free immunosensing of YKL-40. Details of the synthesis of YKL-40 and production of anti-YKL-40 immunoglobulin G (IgG) are provided and cross-reactivity tests presented. Polyclonal anti-YKL-40 IgG was immobilized on gold electrodes and the resulting immunosensors were operated in an electrochemical flow system with capacitive signal generation. The strategy offered a wide linear detection range (0.1μg/L to 1mg/L) with correlation coefficients (R(2)) above 0.99 and good sensitivity (12.28±0.27nF/cm(2) per decade of concentration change). Additionally, the detection limit of 0.07±0.01μg/L was well below that of optical enzyme-linked immunosorbent assays (ELISAs), which makes the proposed methodology a promising alternative for YKL-40 related disease studies.
Collapse
Affiliation(s)
- Wethaka Chaocharoen
- Biochemistry-Electrochemistry Research Unit, Schools of Chemistry and Biochemistry, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Wipa Suginta
- Biochemistry-Electrochemistry Research Unit, Schools of Chemistry and Biochemistry, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Warakorn Limbut
- Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Applied Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Araya Ranok
- Biochemistry-Electrochemistry Research Unit, Schools of Chemistry and Biochemistry, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Apon Numnuam
- Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Panida Khunkaewla
- Biochemistry-Electrochemistry Research Unit, Schools of Chemistry and Biochemistry, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand
| | - Proespichaya Kanatharana
- Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Panote Thavarungkul
- Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Physics, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
| | - Albert Schulte
- Biochemistry-Electrochemistry Research Unit, Schools of Chemistry and Biochemistry, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand.
| |
Collapse
|
26
|
Jung HW, Chang YW, Lee GY, Cho S, Kang MJ, Pyun JC. A capacitive biosensor based on an interdigitated electrode with nanoislands. Anal Chim Acta 2014; 844:27-34. [PMID: 25172812 DOI: 10.1016/j.aca.2014.07.006] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 07/01/2014] [Accepted: 07/08/2014] [Indexed: 01/30/2023]
Abstract
A capacitive biosensor based on an interdigitated electrode (IDE) with nanoislands was developed for label-free detection of antigen-antibody interactions. To enable sensitive capacitive detection of protein adsorption, the nanoislands were fabricated between finger electrodes of the IDE. The effect of the nanoislands on the sensitive capacitive measurement was estimated using horseradish peroxidase (HRP) as a model protein. Additionally, a parylene-A film was coated on the IDE with nanoislands to improve the efficiency of protein immobilization. By using HRP and hepatitis B virus surface antigen (HBsAg) as model analytes, the effect of the parylene-A film on the capacitive detection of protein adsorption was demonstrated.
Collapse
Affiliation(s)
- Ha-Wook Jung
- Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, South Korea
| | - Young Wook Chang
- Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, South Korea
| | - Ga-yeon Lee
- Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, South Korea
| | - Sungbo Cho
- Department of Biomedical Engineering, Gachon University, Incheon 406-799, South Korea
| | - Min-Jung Kang
- Korea Institute of Science and Technology (KIST), Seoul, South Korea
| | - Jae-Chul Pyun
- Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, South Korea.
| |
Collapse
|
27
|
Introducing a new method for evaluation of the interaction between an antigen and an antibody: Single frequency impedance analysis for biosensing systems. Talanta 2014; 125:7-13. [DOI: 10.1016/j.talanta.2014.02.067] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2013] [Revised: 02/20/2014] [Accepted: 02/25/2014] [Indexed: 11/22/2022]
|
28
|
Lebogang L, Hedström M, Mattiasson B. Development of a real-time capacitive biosensor for cyclic cyanotoxic peptides based on Adda-specific antibodies. Anal Chim Acta 2014; 826:69-76. [PMID: 24793855 DOI: 10.1016/j.aca.2014.03.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 03/11/2014] [Accepted: 03/21/2014] [Indexed: 10/25/2022]
Abstract
The harmful effects of cyanotoxins in surface waters have led to increasing demands for accurate early warning methods. This study proposes a capacitive immunosensor for broad-spectrum detection of the group of toxic cyclic peptides called microcystins (∼80 congeners) at very low concentration levels. The novel analytical platform offers significant advances compared to the existing methods. Monoclonal antibodies (mAbs, clone AD4G2) that recognize a common element of microcystins were used to construct the biosensing layer. Initially, a stable insulating anchor layer for the mAbs was made by electropolymerization of tyramine onto a gold electrode surface, with subsequent incorporation of gold nanoparticles (AuNPs) on the glutaraldehyde (5%) activated polytyramine surface. The biosensor responded linearly to microcystin concentrations from 1×10(-13)M to 1×10(-10)M MC-LR standard with a limit of detection of 2.1×10(-14)M. The stability of the biosensor was evaluated by repeated measurements of the antigen and by determining the capacitance change relative to the original response, which decreased below 90% after the 30th cycle.
Collapse
Affiliation(s)
- Lesedi Lebogang
- Department of Biotechnology, Lund University, Box 124, 22100 Lund, Sweden
| | - Martin Hedström
- Department of Biotechnology, Lund University, Box 124, 22100 Lund, Sweden.
| | - Bo Mattiasson
- Department of Biotechnology, Lund University, Box 124, 22100 Lund, Sweden; CapSenze HB, Annersbergs gård 5520, 26021 Billeberga, Sweden
| |
Collapse
|
29
|
Hamon M, Hong JW. New tools and new biology: recent miniaturized systems for molecular and cellular biology. Mol Cells 2013; 36:485-506. [PMID: 24305843 PMCID: PMC3887968 DOI: 10.1007/s10059-013-0333-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2013] [Accepted: 11/14/2013] [Indexed: 01/09/2023] Open
Abstract
Recent advances in applied physics and chemistry have led to the development of novel microfluidic systems. Microfluidic systems allow minute amounts of reagents to be processed using μm-scale channels and offer several advantages over conventional analytical devices for use in biological sciences: faster, more accurate and more reproducible analytical performance, reduced cell and reagent consumption, portability, and integration of functional components in a single chip. In this review, we introduce how microfluidics has been applied to biological sciences. We first present an overview of the fabrication of microfluidic systems and describe the distinct technologies available for biological research. We then present examples of microsystems used in biological sciences, focusing on applications in molecular and cellular biology.
Collapse
Affiliation(s)
- Morgan Hamon
- Materials Research and Education Center, Department of Mechanical Engineering, Auburn University, Auburn, AL 36849,
USA
| | - Jong Wook Hong
- Materials Research and Education Center, Department of Mechanical Engineering, Auburn University, Auburn, AL 36849,
USA
- College of Pharmacy, Seoul National University, Seoul 151-741,
Korea
- Department of Bionano Engineering, Hanyang University, Ansan 426-791,
Korea
| |
Collapse
|
30
|
|
31
|
Venkatanarayanan A, Keyes TE, Forster RJ. Label-Free Impedance Detection of Cancer Cells. Anal Chem 2013; 85:2216-22. [DOI: 10.1021/ac302943q] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Anita Venkatanarayanan
- Biomedical Diagnostics Institute, National
Center for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Tia E. Keyes
- Biomedical Diagnostics Institute, National
Center for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Robert J. Forster
- Biomedical Diagnostics Institute, National
Center for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| |
Collapse
|
32
|
Lee GY, Choi YH, Chung HW, Ko H, Cho S, Pyun JC. Capacitive immunoaffinity biosensor based on vertically paired ring-electrodes. Biosens Bioelectron 2013; 40:227-32. [DOI: 10.1016/j.bios.2012.07.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2012] [Revised: 07/12/2012] [Accepted: 07/18/2012] [Indexed: 11/16/2022]
|
33
|
|
34
|
Singh S, Srivastava A, Oh HM, Ahn CY, Choi GG, Asthana RK. Recent trends in development of biosensors for detection of microcystin. Toxicon 2012; 60:878-94. [DOI: 10.1016/j.toxicon.2012.06.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2011] [Revised: 05/08/2012] [Accepted: 06/06/2012] [Indexed: 01/14/2023]
|
35
|
Samanman S, Kanatharana P, Asawatreratanakul P, Thavarungkul P. Characterization and application of self-assembled layer by layer gold nanoparticles for highly sensitive label-free capacitive immunosensing. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.07.016] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
36
|
YAN XF, WANG MH, AN D. Progress of Interdigitated Array Microelectrodes Based Impedance Immunosensor. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2012. [DOI: 10.3724/sp.j.1096.2011.01601] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
37
|
Capacitive immunosensor for the detection of host cell proteins. J Biotechnol 2012; 157:207-13. [DOI: 10.1016/j.jbiotec.2011.11.004] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2011] [Revised: 10/31/2011] [Accepted: 11/02/2011] [Indexed: 11/17/2022]
|
38
|
YAN XF, WANG MH, AN D. Progress of Interdigitated Array Microelectrodes Based Impedance Immunosensor. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2011. [DOI: 10.1016/s1872-2040(10)60478-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
39
|
Dawan S, Kanatharana P, Wongkittisuksa B, Limbut W, Numnuam A, Limsakul C, Thavarungkul P. Label-free capacitive immunosensors for ultra-trace detection based on the increase of immobilized antibodies on silver nanoparticles. Anal Chim Acta 2011; 699:232-41. [DOI: 10.1016/j.aca.2011.05.038] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 05/17/2011] [Accepted: 05/24/2011] [Indexed: 10/18/2022]
|
40
|
A fast and simple electrochemical impedance spectroscopy measurement technique and its application in portable, low-cost instrument for impedimetric biosensing. J Electroanal Chem (Lausanne) 2011. [DOI: 10.1016/j.jelechem.2011.04.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
41
|
Development and application of a real-time capacitive sensor. Biosens Bioelectron 2011; 26:2466-72. [DOI: 10.1016/j.bios.2010.10.033] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2010] [Revised: 10/12/2010] [Accepted: 10/21/2010] [Indexed: 02/03/2023]
|
42
|
Rusling JF, Kumar CV, Gutkind JS, Patel V. Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer. Analyst 2010; 135:2496-511. [PMID: 20614087 DOI: 10.1039/c0an00204f] [Citation(s) in RCA: 361] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
This critical review evaluates progress toward viable point-of-care protein biomarker measurements for cancer detection and diagnostics. The ability to measure panels of specific, selective cancer biomarker proteins in physicians' surgeries and clinics has the potential to revolutionize cancer detection, monitoring, and therapy. The dream envisions reliable, cheap, automated, technically undemanding devices that can analyze a patient's serum or saliva in a clinical setting, allowing on-the-spot diagnosis. Existing commercial products for protein assays are reliable in laboratory settings, but have limitations for point-of-care applications. A number of ultrasensitive immunosensors and some arrays have been developed, many based on nanotechnology. Multilabel detection coupled with high capture molecule density in immunosensors and arrays seems to be capable of detecting a wide range of protein concentrations with sensitivity ranging into the sub pg mL(-1) level. Multilabel arrays can be designed to detect both high and ultralow abundance proteins in the same sample. However, only a few of the newer ultrasensitive methods have been evaluated with real patient samples, which is key to establishing clinical sensitivity and selectivity.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA.
| | | | | | | |
Collapse
|
43
|
|
44
|
Competitive capacitive biosensing technique (CCBT): a novel technique for monitoring low molecular mass analytes using glucose assay as a model study. Anal Bioanal Chem 2010; 397:1217-24. [PMID: 20401723 DOI: 10.1007/s00216-010-3641-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2009] [Revised: 03/04/2010] [Accepted: 03/07/2010] [Indexed: 01/03/2023]
Abstract
A novel technique for monitoring of low molecular mass analytes using a flow-injection capacitive biosensor is presented. The method is based on the ability of a small molecular mass analyte to displace a large analyte-carrier conjugate from the binding sites of an immobilized biorecognition element with weak affinity to both compounds. A model study was performed on glucose as the small molecular mass analyte. In the absence of glucose, binding of a glucose polymer or a glycoconjugate to concanavalin A results in a capacitance decrease. Upon introduction of glucose, it displaces a part of the bound glucose polymer or glycoconjugate leading to a partial restoration of capacitance. Experimental results show that the change in capacitance depends linearly on glucose concentration within the range from 1.0 x 10(-5) to 1.0 x 10(-1) M, corresponding to 1.8 microg ml(-1) to 18 mg ml(-1) in a logarithmic plot, with a detection limit of 1.0 x 10(-6) (0.18 microg ml(-1)) under optimized conditions. In addition, by modifying the molecular mass of the glucose polymer, amount of biorecognition element, and buffer composition, we were able to tune the analyte-sensing range. The developed technique has the benefits of expanded dynamic range, high sensitivity, and excellent reusability.
Collapse
|
45
|
Kang B, Yeo U, Yoo KH. Anodized aluminum oxide-based capacitance sensors for the direct detection of DNA hybridization. Biosens Bioelectron 2010; 25:1592-6. [DOI: 10.1016/j.bios.2009.11.017] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2009] [Revised: 11/11/2009] [Accepted: 11/17/2009] [Indexed: 10/20/2022]
|
46
|
Limbut W, Thavarungkul P, Kanatharana P, Wongkittisuksa B, Asawatreratanakul P, Limsakul C. Cost-effective disposable thiourea film modified copper electrode for capacitive immunosensor. Electrochim Acta 2010. [DOI: 10.1016/j.electacta.2010.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
47
|
Han HJ, Kannan RM, Wang S, Mao G, Kusanovic JP, Romero R. Multifunctional Dendrimer-templated Antibody Presentation on Biosensor Surfaces for Improved Biomarker Detection. ADVANCED FUNCTIONAL MATERIALS 2010; 20:409-421. [PMID: 26290658 PMCID: PMC4538936 DOI: 10.1002/adfm.200901293] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Dendrimers, with their well-defined globular shape and a high density of functional groups, are ideal nanoscale materials for templating sensor surfaces. This work exploits dendrimers as a versatile platform for capturing biomarkers with improved sensitivity and specificity. Synthesis, characterization, fabrication, and functional validation of the dendrimer-based assay platform are described. Bifunctional hydroxyl/thiol functionalized G4-polyamidoamine (PAMAM) dendrimer is synthesized and immobilized on to the polyethylene-glycol (PEG)-functionalized assay plate by coupling PEG-maleimide and dendrimer thiol groups. Simultaneously, part of the dendrimer thiol groups are converted to hydrazide functionalities. The resulting dendrimer-modified surface is coupled to the capture antibody in the Fc region of the oxidized antibody. This preserves the orientation flexibility of the antigen binding region (Fv) of the antibody. To validate the approach, the fabricated plates are further used as a solid phase for developing a sandwich type ELISA to detect IL-6 and IL-1β, important biomarkers for early stages of chorioamnionitis. The dendrimer-modified plate provides assays with significantly enhanced sensitivity, lower nonspecific adsorption, and a detection limit of 0.13 pg ml-1 for IL-6 luminol detection and 1.15 pg ml-1 for IL-1β TMB detection, which are significantly better than those for the traditional ELISA. The assays were validated in human serum samples from normal (non-pregnant) woman and pregnant women with pyelonephritis. The specificity and the improved sensitivity of the dendrimer-based capture strategy could have significant implications for the detection of a wide range of cytokines and biomarkers since the capture strategy could be applied to multiplex microbead assays, conductometric immunosensors and field effect biosensors.
Collapse
Affiliation(s)
- Hye Jung Han
- Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan 48202 (U. S. A.) and Eunice Kennedy Shriver National Institute of Child Health and Human Development, NICHD, NIH, DHHS, Detroit, MI 48201 (U. S. A.)
| | - Rangaramanujam M. Kannan
- Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan 48202 (U. S. A.) and Eunice Kennedy Shriver National Institute of Child Health and Human Development, NICHD, NIH, DHHS, Detroit, MI 48201 (U. S. A.)
| | - Sunxi Wang
- Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan 48202 (U. S. A.)
| | - Guangzhao Mao
- Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan 48202 (U. S. A.)
| | - Juan Pedro Kusanovic
- Perinatology Research Branch NICHD/NIH/DHHS, Department of Obstetrics and Gynecology, Wayne State University, Hutzel Women’s Hospital, Detroit, MI 48201 (U. S. A.)
| | - Roberto Romero
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, NICHD, NIH, DHHS, Detroit, MI 48201 (U. S. A.)
| |
Collapse
|
48
|
Labib M, Hedström M, Amin M, Mattiasson B. A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrode. Anal Chim Acta 2010; 659:194-200. [DOI: 10.1016/j.aca.2009.11.028] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2009] [Revised: 11/09/2009] [Accepted: 11/11/2009] [Indexed: 10/20/2022]
|
49
|
Nano-bio-technology and sensing chips: new systems for detection in personalized therapies and cell biology. SENSORS 2010; 10:526-43. [PMID: 22315554 PMCID: PMC3270855 DOI: 10.3390/s100100526] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2009] [Revised: 12/30/2009] [Accepted: 01/05/2010] [Indexed: 11/17/2022]
Abstract
Further advances in molecular medicine and cell biology also require new electrochemical systems to detect disease biomarkers and therapeutic compounds. Microelectronic technology offers powerful circuits and systems to develop innovative and miniaturized biochips for sensing at the molecular level. However, microelectronic biochips proposed in the literature often do not show the right specificity, sensitivity, and reliability required by biomedical applications. Nanotechnology offers new materials and solutions to improve the surface properties of sensing probes. The aim of the present paper is to review the most recent progress in Nano-Bio-Technology in the area of the development of new electrochemical systems for molecular detection in personalized therapy and cell culture monitoring.
Collapse
|
50
|
WU Z, CAO Z, ZENG JL, ZHANG L, CHU X, SHEN GL, YU RQ. A Reusable Capacitive Immunosensor Based on a CuS Ultrathin Film Constructed by Using a Surface Sol-Gel Technique. ANAL SCI 2010; 26:1001-6. [DOI: 10.2116/analsci.26.1001] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|