1
|
Zhang K, Zhang L. Determination of Patulin in Apple Juice and Apple-Derived Products Using a Robotic Sample Preparation System and LC-APCI-MS/MS. Toxins (Basel) 2024; 16:238. [PMID: 38922133 PMCID: PMC11209136 DOI: 10.3390/toxins16060238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 05/16/2024] [Accepted: 05/18/2024] [Indexed: 06/27/2024] Open
Abstract
Patulin, a toxic mycotoxin, can contaminate apple-derived products. The FDA has established an action level of 50 ppb (ng/g) for patulin in apple juice and apple juice products. To effectively monitor this mycotoxin, there is a need for adequate analytical methods that can reliably and efficiently determine patulin levels. In this work, we developed an automated sample preparation workflow followed by liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI-MS/MS) detection to identify and quantify patulin in a single method, further expanding testing capabilities for monitoring patulin in foods compared to traditional optical methods. Using a robotic sample preparation system, apple juice, apple cider, apple puree, apple-based baby food, applesauce, fruit rolls, and fruit jam were fortified with 13C-patulin and extracted using dichloromethane (DCM) without human intervention, followed by an LC-APCI-MS/MS analysis in negative ionization mode. The method achieved a limit of quantification of 4.0 ng/g and linearity ranging from 2 to 1000 ng/mL (r2 > 0.99). Quantitation was performed with isotope dilution using 13C-patulin as an internal standard and solvent calibration standards. Average recoveries (relative standard deviations, RSD%) in seven spike matrices were 95% (9%) at 10 ng/g, 110% (5%) at 50 ng/g, 101% (7%) at 200 ng/g, and 104% (4%) at 1000 ng/g (n = 28). The ranges of within-matrix and between-matrix variability (RSD) were 3-8% and 4-9%, respectively. In incurred samples, the identity of patulin was further confirmed with a comparison of the information-dependent acquisition-enhanced product ion (IDA-EPI) MS/MS spectra to a reference standard. The metrological traceability of the patulin measurements in an incurred apple cider (21.1 ± 8.0 µg/g) and apple juice concentrate (56.6 ± 15.6 µg/g) was established using a certified reference material and calibration data to demonstrate data confidence intervals (k = 2, 95% confidence interval).
Collapse
Affiliation(s)
- Kai Zhang
- U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, 5001 Campus Drive, College Park, MD 20740, USA;
| | | |
Collapse
|
2
|
Huang Q, Zhou H, Wu X, Song C, Zheng J, Lei M, Mu P, Wu P. Simultaneous determination of the residues of anesthetics and sedatives in fish using LC-QLIT-MS/MS combined with DSPE. Food Chem 2023; 403:134407. [PMID: 36183462 DOI: 10.1016/j.foodchem.2022.134407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 09/14/2022] [Accepted: 09/22/2022] [Indexed: 11/26/2022]
Abstract
Liquid chromatography coupled with quadrupole linear ion trap tandem mass spectrometry (LC-QLIT-MS/MS) technology operated in electrospray ionization (ESI) was developed for tracing anesthetic (AETs) and sedatives (SDTs) in fish. Sampling procedure was achieved by using acetonitrile extraction followed by dispersive solid phase extraction (DSPE) clean-up. Under the optimized laboratory conditions, reliable qualitative confirmation was obtained through the multiple reaction monitoring-information dependent acquisition-enhanced product ion (MRM-IDA-EPI) mode. Results indicated a favorable linear in the concentration range of 1-100 μg∙kg-1 (0.1-10 μg∙kg-1 for MS-222), with regression coefficient not less than 0.9997. The detection limit ranges from 0.03 to 0.4 μg∙kg-1 (S/N = 3). The validated method was applied to determine AETs and SDTs in fish with satidfied recoveries of 86.3 %-111.7 % and the relative standard deviations (RSD) of 1.9 %-8.9 % (n = 6). Practical samples analysis indicated that the proposed method is simple, rapid, sensitive and accurate for identification of AETs and SDTs.
Collapse
|
3
|
Abstract
The extensive use of pesticides represents a risk to human health. Consequently, legal frameworks have been established to ensure food safety, including control programs for pesticide residues. In this context, the performance of analytical methods acquires special relevance. Such methods are expected to be able to determine the largest number of compounds at trace concentration levels in complex food matrices, which represents a great analytical challenge. Technical advances in mass spectrometry (MS) have led to the development of more efficient analytical methods for the determination of pesticides. This review provides an overview of current analytical strategies applied in pesticide analysis, with a special focus on MS methods. Current targeted MS methods allow the simultaneous determination of hundreds of pesticides, whereas non-targeted MS methods are now applicable to the identification of pesticide metabolites and transformation products. New trends in pesticide analysis are also presented, including approaches for the simultaneous determination of pesticide residues and other food contaminants (i.e., mega-methods), or the recent application of techniques such as ion mobility–mass spectrometry (IM–MS) for this purpose.
Collapse
|
4
|
Zhang K, Tan S, Xu D. Determination of Mycotoxins in Dried Fruits Using LC-MS/MS-A Sample Homogeneity, Troubleshooting and Confirmation of Identity Study. Foods 2022; 11:foods11060894. [PMID: 35327316 PMCID: PMC8954288 DOI: 10.3390/foods11060894] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/11/2022] [Accepted: 03/17/2022] [Indexed: 01/27/2023] Open
Abstract
To monitor co-exposure to toxic mycotoxins in dried fruits, it is advantageous to simultaneously determine multiple mycotoxins using a single extraction and liquid chromatography with tandem mass spectrometry (LC-MS/MS) analysis. In this study, we applied a stable isotope dilution and LC-MS/MS method to multi-mycotoxin analysis in dried fruits, selecting raisins, plums, figs, and cranberries for matrix extension. Samples were prepared using cryogenic grinding, followed by the fortification of carbon-13 (13C) uniformly labeled internal standards for twelve mycotoxins, and extraction using 50% acetonitrile. Homogeneity of prepared samples, defined as particle size Dv90 < 850 µm for the tested matrices, was characterized using a laser diffraction particle size analyzer, and reached using cryogenic grinding procedures. The majority of recoveries in the four matrices for aflatoxins and ochratoxin A spiked at 1−100 ng/g; fumonisins, T-2 toxin, HT-2 toxin, and zearalenone spiked at 10−1000 ng/g, ranged from 80 to 120% with relative standard deviations (RSDs) of <20%. Deoxynivalenol was not detected at 10 and 100 ng/g in plums, and additional troubleshooting procedures using liquid-liquid extraction (LLE), solid phase extraction (SPE), and elution gradient were evaluated to improve the detectability of the mycotoxin. Furthermore, we confirmed the identity of detected mycotoxins, ochratoxin A and deoxynivalenol, in incurred samples using enhanced product ion scans and spectral library matching.
Collapse
Affiliation(s)
- Kai Zhang
- US Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, HFS-717. 5001 Campus Drive, College Park, MD 20740, USA;
- Correspondence: ; Tel.: +1-240-402-2318
| | - Steven Tan
- US Food and Drug Administration, Center for Food Safety and Applied Nutrition, Office of Regulatory Science, HFS-717. 5001 Campus Drive, College Park, MD 20740, USA;
- Joint Institute for Food Safety and Applied Nutrition, University of Maryland, 2134 Patapsco Building, 5145 Campus Drive, College Park, MD 20740, USA;
| | - David Xu
- Joint Institute for Food Safety and Applied Nutrition, University of Maryland, 2134 Patapsco Building, 5145 Campus Drive, College Park, MD 20740, USA;
| |
Collapse
|
5
|
Song Q, Li J, Cao Y, Liu W, Huo H, Wan JB, Song Y, Tu P. Binary code, a flexible tool for diagnostic metabolite sequencing of medicinal plants. Anal Chim Acta 2019; 1088:89-98. [DOI: 10.1016/j.aca.2019.08.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 08/16/2019] [Accepted: 08/17/2019] [Indexed: 12/22/2022]
|
6
|
Chawla P, Kaushik R, Shiva Swaraj V, Kumar N. Organophosphorus pesticides residues in food and their colorimetric detection. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.enmm.2018.07.013] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
7
|
Wong JW, Wang J, Chow W, Carlson R, Jia Z, Zhang K, Hayward DG, Chang JS. Perspectives on Liquid Chromatography-High-Resolution Mass Spectrometry for Pesticide Screening in Foods. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2018; 66:9573-9581. [PMID: 30169025 DOI: 10.1021/acs.jafc.8b03468] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
This perspective discusses the use of liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for multiresidue analysis of pesticides in foods and agricultural commodities. HRMS has the important distinction and advantage of mass-resolving power and, therefore, requires different concepts, experiments, and guidance for screening, identification, and quantitation of pesticides in complex food matrices over triple quadrupole mass spectrometry. HRMS approaches for pesticide screening, including full-scan experiments in conjunction with tandem mass spectrometry (MS/MS) experiments, are described. This approach results in the generation of chromatographic retention times and high-resolution mass spectra with accurate mass measurements that can be used to create compound databases. New data processing tools can create an efficient and optimized screening approach that can speed the analysis and identification of compounds, reduce the need for chemical standards, and harmonize pesticide analytical procedures.
Collapse
Affiliation(s)
- Jon W Wong
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - Jian Wang
- Calgary Laboratory , Canadian Food Inspection Agency , 3650 36th Street Northwest , Calgary , Alberta T2L 2L1 , Canada
| | - Willis Chow
- Calgary Laboratory , Canadian Food Inspection Agency , 3650 36th Street Northwest , Calgary , Alberta T2L 2L1 , Canada
| | - Roland Carlson
- Center for Analytical Chemistry , California Department of Food and Agriculture , 3292 Meadowview Road , Sacramento , California 95832 , United States
| | - Zhengwei Jia
- Shanghai Institute for Food and Drug Control (SIFDC) , 1500 Zhangheng Road , Shanghai 210203 , People's Republic of China
| | - Kai Zhang
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - Douglas G Hayward
- Center for Food Safety and Applied Nutrition , United States Food and Drug Administration , 5001 Campus Drive , College Park , Maryland 20740 , United States
| | - James S Chang
- Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States
| |
Collapse
|
8
|
De Vijlder T, Valkenborg D, Lemière F, Romijn EP, Laukens K, Cuyckens F. A tutorial in small molecule identification via electrospray ionization-mass spectrometry: The practical art of structural elucidation. MASS SPECTROMETRY REVIEWS 2018; 37:607-629. [PMID: 29120505 PMCID: PMC6099382 DOI: 10.1002/mas.21551] [Citation(s) in RCA: 124] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 10/03/2017] [Indexed: 05/10/2023]
Abstract
The identification of unknown molecules has been one of the cornerstone applications of mass spectrometry for decades. This tutorial reviews the basics of the interpretation of electrospray ionization-based MS and MS/MS spectra in order to identify small-molecule analytes (typically below 2000 Da). Most of what is discussed in this tutorial also applies to other atmospheric pressure ionization methods like atmospheric pressure chemical/photoionization. We focus primarily on the fundamental steps of MS-based structural elucidation of individual unknown compounds, rather than describing strategies for large-scale identification in complex samples. We critically discuss topics like the detection of protonated and deprotonated ions ([M + H]+ and [M - H]- ) as well as other adduct ions, the determination of the molecular formula, and provide some basic rules on the interpretation of product ion spectra. Our tutorial focuses primarily on the fundamental steps of MS-based structural elucidation of individual unknown compounds (eg, contaminants in chemical production, pharmacological alteration of drugs), rather than describing strategies for large-scale identification in complex samples. This tutorial also discusses strategies to obtain useful orthogonal information (UV/Vis, H/D exchange, chemical derivatization, etc) and offers an overview of the different informatics tools and approaches that can be used for structural elucidation of small molecules. It is primarily intended for beginning mass spectrometrists and researchers from other mass spectrometry sub-disciplines that want to get acquainted with structural elucidation are interested in some practical tips and tricks.
Collapse
Affiliation(s)
- Thomas De Vijlder
- Pharmaceutical Development & Manufacturing Sciences (PDMS)Janssen Research & DevelopmentBeerseBelgium
| | - Dirk Valkenborg
- Interuniversity Institute for Biostatistics and Statistical BioinformaticsHasselt UniversityDiepenbeekBelgium
- Center for Proteomics (CFP)University of AntwerpAntwerpBelgium
- Flemish Institute for Technological Research (VITO)MolBelgium
| | - Filip Lemière
- Center for Proteomics (CFP)University of AntwerpAntwerpBelgium
- Department of Chemistry, Biomolecular and Analytical Mass SpectrometryUniversity of AntwerpAntwerpBelgium
| | - Edwin P. Romijn
- Pharmaceutical Development & Manufacturing Sciences (PDMS)Janssen Research & DevelopmentBeerseBelgium
| | - Kris Laukens
- Department of Mathematics and Computer Science, Advanced Database Research and Modelling (ADReM)University of AntwerpAntwerpBelgium
- Biomedical Informatics Network Antwerp (Biomina)University of AntwerpAntwerpBelgium
| | - Filip Cuyckens
- Pharmacokinetics, Dynamics & MetabolismJanssen Research & DevelopmentBeerseBelgium
| |
Collapse
|
9
|
Kind T, Tsugawa H, Cajka T, Ma Y, Lai Z, Mehta SS, Wohlgemuth G, Barupal DK, Showalter MR, Arita M, Fiehn O. Identification of small molecules using accurate mass MS/MS search. MASS SPECTROMETRY REVIEWS 2018; 37:513-532. [PMID: 28436590 PMCID: PMC8106966 DOI: 10.1002/mas.21535] [Citation(s) in RCA: 249] [Impact Index Per Article: 41.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 03/17/2017] [Accepted: 03/18/2017] [Indexed: 05/03/2023]
Abstract
Tandem mass spectral library search (MS/MS) is the fastest way to correctly annotate MS/MS spectra from screening small molecules in fields such as environmental analysis, drug screening, lipid analysis, and metabolomics. The confidence in MS/MS-based annotation of chemical structures is impacted by instrumental settings and requirements, data acquisition modes including data-dependent and data-independent methods, library scoring algorithms, as well as post-curation steps. We critically discuss parameters that influence search results, such as mass accuracy, precursor ion isolation width, intensity thresholds, centroiding algorithms, and acquisition speed. A range of publicly and commercially available MS/MS databases such as NIST, MassBank, MoNA, LipidBlast, Wiley MSforID, and METLIN are surveyed. In addition, software tools including NIST MS Search, MS-DIAL, Mass Frontier, SmileMS, Mass++, and XCMS2 to perform fast MS/MS search are discussed. MS/MS scoring algorithms and challenges during compound annotation are reviewed. Advanced methods such as the in silico generation of tandem mass spectra using quantum chemistry and machine learning methods are covered. Community efforts for curation and sharing of tandem mass spectra that will allow for faster distribution of scientific discoveries are discussed.
Collapse
Affiliation(s)
- Tobias Kind
- Genome Center, Metabolomics, UC Davis, Davis, California
| | - Hiroshi Tsugawa
- RIKEN Center for Sustainable Resource Science, Yokohama, Kanagawa, Japan
| | - Tomas Cajka
- Genome Center, Metabolomics, UC Davis, Davis, California
| | - Yan Ma
- National Institute of Biological Sciences, Beijing, People’s Republic of China
| | - Zijuan Lai
- Genome Center, Metabolomics, UC Davis, Davis, California
| | | | | | | | | | - Masanori Arita
- RIKEN Center for Sustainable Resource Science, Yokohama, Kanagawa, Japan
| | - Oliver Fiehn
- Genome Center, Metabolomics, UC Davis, Davis, California
- Faculty of Sciences, Department of Biochemistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
10
|
He Z, Wang Y, Xu Y, Liu X. Determination of Antibiotics in Vegetables Using QuEChERS-Based Method and Liquid Chromatography-Quadrupole Linear Ion Trap Mass Spectrometry. FOOD ANAL METHOD 2018. [DOI: 10.1007/s12161-018-1252-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
11
|
Supercritical fluid chromatography–tandem mass spectrometry-assisted methodology for rapid enantiomeric analysis of fenbuconazole and its chiral metabolites in fruits, vegetables, cereals, and soil. Food Chem 2018; 241:32-39. [DOI: 10.1016/j.foodchem.2017.08.038] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 06/22/2017] [Accepted: 08/12/2017] [Indexed: 11/23/2022]
|
12
|
Bianchi F, Riboni N, Termopoli V, Mendez L, Medina I, Ilag L, Cappiello A, Careri M. MS-Based Analytical Techniques: Advances in Spray-Based Methods and EI-LC-MS Applications. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2018; 2018:1308167. [PMID: 29850370 PMCID: PMC5937452 DOI: 10.1155/2018/1308167] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Accepted: 02/26/2018] [Indexed: 05/15/2023]
Abstract
Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.
Collapse
Affiliation(s)
- Federica Bianchi
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| | - Nicolò Riboni
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Veronica Termopoli
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Lucia Mendez
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Isabel Medina
- Instituto de Investigaciones Marinas, Spanish National Research Council (IIM-CSIC), Eduardo Cabello 6, 36208 Vigo, Spain
| | - Leopold Ilag
- Department of Environmental Science and Analytical Chemistry, Stockholm University, 10691 Stockholm, Sweden
| | - Achille Cappiello
- Department of Pure and Applied Sciences, LC-MS Laboratory, Piazza Rinascimento 6, 61029 Urbino, Italy
| | - Maria Careri
- Department of Chemistry, Life Sciences, and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
| |
Collapse
|
13
|
Zhang WB, Wei M, Song W, Gong YX, Yang XA. Evaluation of Pyridaben Residues on Fruit Surfaces and Their Stability by a Novel On-Line Dual-Frequency Ultrasonic Device and Chemiluminescence Detection. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2017; 65:9799-9806. [PMID: 29016120 DOI: 10.1021/acs.jafc.7b03357] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this paper, we first report the development of a highly sensitive and economical method for accurate analysis of pyridaben residues on fruits based on dual-frequency ultrasonic treatment (DFUT) and flow injection chemiluminescence (CL) detection. The DFUT device is made by integrating an ultrasonic bath with an ultrasonic probe. Two quartz glass coils (QGC) with different structures have been designed and applied to evaluate the function of DFUT in the detection process. Recorded data showed that DFUT is an effective method for improving the pyridaben CL signal. The signal of pyridaben in response to DFUT is 2.0-3.3 times stronger than the response to only the ultrasonic probe at 20 kHz or the ultrasonic bath at 40 kHz. In addition, the response obtained from the concentric circle QGC is 2.1 times stronger than the response to the spiral tube QGC. Under the optimized condition, the proposed method has advantages, such as a wide linear range (0.8-100.0 μg L-1), a high sensitivity (limit of detection of 0.085 μg L-1), and good stability (RSDs ≤ 4.7% in the linear range) for pyridaben determination. We apply this method to monitor the residue pyridaben on some fruits. The data show that the maximum amounts of the residue on fruit surfaces after soaking in water (50 mg L-1, 5 min) are 0.583 mg kg-1 (apple), 0.794 mg kg-1 (orange), and 0.351 mg kg-1 (pear). However, the concentration of pyridaben in the presence of sunlight decreases rapidly, showing its poor light stability.
Collapse
Affiliation(s)
- Wang-Bing Zhang
- Department of Applied Chemistry, Anhui University of Technology , Maanshan, Anhui 243002, P. R. China
| | - Min Wei
- Department of Applied Chemistry, Anhui University of Technology , Maanshan, Anhui 243002, P. R. China
| | - Wei Song
- Anhui Entry Exit Inspection and Quarantine Bureau , Hefei, Anhui 230022, P. R. China
| | - Yi-Xuan Gong
- Department of Applied Chemistry, Anhui University of Technology , Maanshan, Anhui 243002, P. R. China
| | - Xin-An Yang
- Department of Applied Chemistry, Anhui University of Technology , Maanshan, Anhui 243002, P. R. China
| |
Collapse
|
14
|
Masiá A, Suarez-Varela MM, Llopis-Gonzalez A, Picó Y. Determination of pesticides and veterinary drug residues in food by liquid chromatography-mass spectrometry: A review. Anal Chim Acta 2016; 936:40-61. [DOI: 10.1016/j.aca.2016.07.023] [Citation(s) in RCA: 162] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 07/10/2016] [Accepted: 07/15/2016] [Indexed: 10/21/2022]
|
15
|
Wide-scope screening of pesticides in fruits and vegetables using information-dependent acquisition employing UHPLC-QTOF-MS and automated MS/MS library searching. Anal Bioanal Chem 2016; 408:7795-7810. [PMID: 27558104 DOI: 10.1007/s00216-016-9883-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Revised: 07/22/2016] [Accepted: 08/15/2016] [Indexed: 10/21/2022]
Abstract
This paper presents an application of ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) for simultaneous screening and identification of 427 pesticides in fresh fruit and vegetable samples. Both full MS scan mode for quantification, and an artificial-intelligence-based product ion scan mode information-dependent acquisition (IDA) providing automatic MS to MS/MS switching of product ion spectra for identification, were conducted by one injection. A home-in collision-induced-dissociation all product ions accurate mass spectra library containing more than 1700 spectra was developed prior to actual application. Both qualitative and quantitative validations of the method were carried out. The result showed that 97.4 % of the pesticides had the screening detection limit (SDL) less than 50 μg kg-1 and more than 86.7 % could be confirmed by accurate MS/MS spectra embodied in the home-made library. Meanwhile, calibration curves covering two orders of magnitude were performed, and they were linear over the concentration range studied for the selected matrices (from 5 to 500 μg kg-1 for most of the pesticides). Recoveries between 80 and 110 % in four matrices (apple, orange, tomato, and spinach) at two spiked levels, 10 and 100 μg kg-1, was 88.7 or 86.8 %. Furthermore, the overall relative standard deviation (RSD, n = 12) for 94.3 % of the pesticides in 10 μg kg-1 and 98.1 % of the pesticides in 100 μg kg-1 spiked levels was less than 20 %. In order to validate the suitability for routine analysis, the method was applied to 448 fruit and vegetable samples purchased in different local markets. The results show 83.3 % of the analyzed samples have positive findings (higher than the limits of identification and quantification), and 412 commodity-pesticide combinations are identified in our scope. The approach proved to be a cost-effective, time-saving and powerful strategy for routine large-scope screening of pesticides.
Collapse
|
16
|
Matraszek-Zuchowska I, Wozniak B, Posyniak A. Comparison of the Multiple Reaction Monitoring and Enhanced Product Ion Scan Modes for Confirmation of Stilbenes in Bovine Urine Samples Using LC-MS/MS QTRAP ® System. Chromatographia 2016; 79:1003-1012. [PMID: 27512157 PMCID: PMC4961723 DOI: 10.1007/s10337-016-3121-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 04/14/2016] [Accepted: 06/09/2016] [Indexed: 12/17/2022]
Abstract
In accordance with Commission Decision 2002/657/EC, confirmatory methods for the detection of prohibited substances should comply with specific requirements, including the criteria for confirmation. Two strategies: multiple reaction monitoring (MRM) and enhanced product ion (EPI) scanning functions were compared for confirming the anabolic compounds from synthetic stilbenes group in bovine urine samples. In the research, twenty samples fortified at the Recommended Concentration (RC) of 1 µg L−1 with diethylstilbestrol, dienestrol and hexestrol were analyzed by liquid chromatography-tandem mass spectrometry on a QTRAP 5500 instrument. The analytical procedure, validated in accordance with the Commission Decision 2002/657/EC, used in the official control of hormones in Poland was applied. The validation parameters were in agreement with 2002/657/EC performance criteria. The effectiveness of MRM and EPI scanning modes for confirmation purposes was evaluated based on the percentage of the results confirmed. In all urine samples recorded in the MRM mode, the confirmation criteria (retention time, relative intensities between transitions) have been fulfilled. The presence of stilbenes in all urine samples using EPI scan mode was confirmed too as evidenced by a good matching of stilbenes spectra in the samples to the reference spectra with critical match factor above 0.7. The results of the research show that EPI scanning function provides the same effectiveness for confirmation of banned compounds as the mostly used MRM scan mode and can be an additional tool to confirm the doubtful case results in the analysis of hormones residues, even at such low concentration levels.
Collapse
Affiliation(s)
- Iwona Matraszek-Zuchowska
- Department of Pharmacology and Toxicology, National Veterinary Research Institute, 24-100 Pulawy, Poland
| | - Barbara Wozniak
- Department of Pharmacology and Toxicology, National Veterinary Research Institute, 24-100 Pulawy, Poland
| | - Andrzej Posyniak
- Department of Pharmacology and Toxicology, National Veterinary Research Institute, 24-100 Pulawy, Poland
| |
Collapse
|
17
|
Villaverde JJ, Sevilla-Morán B, López-Goti C, Alonso-Prados JL, Sandín-España P. Trends in analysis of pesticide residues to fulfil the European Regulation (EC) No. 1107/2009. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.04.017] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
18
|
Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry. Food Chem 2016; 196:1248-55. [DOI: 10.1016/j.foodchem.2015.10.042] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Revised: 10/06/2015] [Accepted: 10/10/2015] [Indexed: 11/16/2022]
|
19
|
He Z, Peng Y, Wang L, Luo M, Liu X. Unequivocal Enantiomeric Identification and Analysis of 10 Chiral Pesticides in Fruit and Vegetables by QuEChERS Method Combined With Liquid Chromatography-Quadruple/Linear Ion Trap Mass Spectrometry Determination. Chirality 2015; 27:958-64. [DOI: 10.1002/chir.22531] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Revised: 08/25/2015] [Accepted: 08/27/2015] [Indexed: 01/31/2023]
Affiliation(s)
- Zeying He
- Agro-Environmental Protection Institute; Ministry of Agriculture; Tianjin P.R. China
| | - Yi Peng
- Agro-Environmental Protection Institute; Ministry of Agriculture; Tianjin P.R. China
| | - Lu Wang
- Agro-Environmental Protection Institute; Ministry of Agriculture; Tianjin P.R. China
| | - Ming Luo
- Agro-Environmental Protection Institute; Ministry of Agriculture; Tianjin P.R. China
| | - Xiaowei Liu
- Agro-Environmental Protection Institute; Ministry of Agriculture; Tianjin P.R. China
| |
Collapse
|
20
|
High-Performance Liquid Chromatography versus Other Modern Analytical Methods for Determination of Pesticides. ACTA ACUST UNITED AC 2015. [DOI: 10.1201/b18481-24] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
21
|
Jadhav MR, Oulkar DP, Shabeer T P A, Banerjee K. Quantitative Screening of Agrochemical Residues in Fruits and Vegetables by Buffered Ethyl Acetate Extraction and LC-MS/MS Analysis. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2015; 63:4449-4456. [PMID: 25639652 DOI: 10.1021/jf505221e] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A buffered ethyl acetate extraction method is proposed for the simultaneous analysis of 296 agrochemicals in a wide range of fruit and vegetable matrices by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The optimized quantity of acetate buffer (1% acetic acid + 0.5 g of sodium acetate per 10 g of sample) adjusted the pH of each test matrix to 5-6, which in turn significantly improved recoveries of acidic and basic compounds. The role of diethylene glycol (used in the evaporation step) on signal suppression of certain compounds was evaluated, and its quantity was optimized to minimize such an effect. The method was validated in grape, mango, drumstick, bitter gourd, capsicum, curry leaf, and okra as per the DG-SANCO/12571/2013 guidelines. Recoveries in the fortification range of 1-40 μg/kg were within 70-120% with associated relative standard deviations below 20% for most of the compounds. The method has potential for regulatory and commercial applications with a generic approach.
Collapse
Affiliation(s)
- Manjusha R Jadhav
- National Referral Laboratory, ICAR-National Research Centre for Grapes, P.O. Manjri Farm, Pune 412307, India
| | - Dasharath P Oulkar
- National Referral Laboratory, ICAR-National Research Centre for Grapes, P.O. Manjri Farm, Pune 412307, India
| | - Ahammed Shabeer T P
- National Referral Laboratory, ICAR-National Research Centre for Grapes, P.O. Manjri Farm, Pune 412307, India
| | - Kaushik Banerjee
- National Referral Laboratory, ICAR-National Research Centre for Grapes, P.O. Manjri Farm, Pune 412307, India
| |
Collapse
|
22
|
Wu H, Guo M, Tan Z, Cheng H, Li Z, Zhai Y. Liquid chromatography quadrupole linear ion trap mass spectrometry for multiclass screening and identification of lipophilic marine biotoxins in bivalve mollusks. J Chromatogr A 2014; 1358:172-80. [DOI: 10.1016/j.chroma.2014.06.105] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2014] [Revised: 05/22/2014] [Accepted: 06/21/2014] [Indexed: 10/25/2022]
|
23
|
Hird SJ, Lau BPY, Schuhmacher R, Krska R. Liquid chromatography-mass spectrometry for the determination of chemical contaminants in food. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.04.005] [Citation(s) in RCA: 81] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
24
|
Castro-Puyana M, Herrero M. Metabolomics approaches based on mass spectrometry for food safety, quality and traceability. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.05.016] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
25
|
The latest developments and applications of mass spectrometry in food-safety and quality analysis. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.08.005] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
26
|
Oberacher H. Applying Tandem Mass Spectral Libraries for Solving the Critical Assessment of Small Molecule Identification (CASMI) LC/MS Challenge 2012. Metabolites 2013; 3:312-24. [PMID: 24957994 PMCID: PMC3901269 DOI: 10.3390/metabo3020312] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Revised: 04/16/2013] [Accepted: 04/17/2013] [Indexed: 11/16/2022] Open
Abstract
The “Critical Assessment of Small Molecule Identification” (CASMI) contest was aimed in testing strategies for small molecule identification that are currently available in the experimental and computational mass spectrometry community. We have applied tandem mass spectral library search to solve Category 2 of the CASMI Challenge 2012 (best identification for high resolution LC/MS data). More than 230,000 tandem mass spectra part of four well established libraries (MassBank, the collection of tandem mass spectra of the “NIST/NIH/EPA Mass Spectral Library 2012”, METLIN, and the ‘Wiley Registry of Tandem Mass Spectral Data, MSforID’) were searched. The sample spectra acquired in positive ion mode were processed. Seven out of 12 challenges did not produce putative positive matches, simply because reference spectra were not available for the compounds searched. This suggests that to some extent the limited coverage of chemical space with high-quality reference spectra is still a problem encountered in tandem mass spectral library search. Solutions were submitted for five challenges. Three compounds were correctly identified (kanamycin A, benzyldiphenylphosphine oxide, and 1-isopropyl-5-methyl-1H-indole-2,3-dione). In the absence of any reference spectrum, a false positive identification was obtained for 1-aminoanthraquinone by matching the corresponding sample spectrum to the structurally related compounds N-phenylphthalimide and 2-aminoanthraquinone. Another false positive result was submitted for 1H-benz[g]indole; for the 1H-benz[g]indole-specific sample spectra provided, carbazole was listed as the best matching compound. In this case, the quality of the available 1H-benz[g]indole-specific reference spectra was found to hamper unequivocal identification.
Collapse
Affiliation(s)
- Herbert Oberacher
- Institute of Legal Medicine and Core Facility Metabolomics, Innsbruck Medical University, Muellerstrasse 44, 6020 Innsbruck, Austria.
| |
Collapse
|
27
|
Flowers SA, Ali L, Lane CS, Olin M, Karlsson NG. Selected reaction monitoring to differentiate and relatively quantitate isomers of sulfated and unsulfated core 1 O-glycans from salivary MUC7 protein in rheumatoid arthritis. Mol Cell Proteomics 2013; 12:921-31. [PMID: 23457413 DOI: 10.1074/mcp.m113.028878] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Rheumatoid arthritis is a common and debilitating systemic inflammatory condition affecting up to 1% of the world's population. This study aimed to investigate the immunological significance of O-glycans in chronic arthritis at a local and systemic level. O-Glycans released from synovial glycoproteins during acute and chronic arthritic conditions were compared and immune-reactive glycans identified. The sulfated core 1 O-glycan (Galβ1-3GalNAcol) was immune reactive, showing a different isomeric profile in the two conditions. From acute reactive arthritis, three isomers could be sequenced, but in patients with chronic rheumatoid arthritis, only a single 3-Gal sulfate-linked isomer could be identified. The systemic significance of this glycan epitope was investigated using the salivary mucin MUC7 in patients with rheumatoid arthritis and normal controls. To analyze this low abundance glycan, a selected reaction monitoring (SRM) method was developed to differentiate and relatively quantitate the core 1 O-glycan and the sulfated core 1 O-glycan Gal- and GalNAc-linked isomers. The acquisition of highly sensitive full scan linear ion trap MS/MS spectra in addition to quantitative SRM data allowed the 3- and 6-linked Gal isomers to be differentiated. The method was used to relatively quantitate the core 1 glycans from MUC7 to identify any systemic changes in this carbohydrate epitope. A statistically significant increase in sulfation was identified in salivary MUC7 from rheumatoid arthritis patients. This suggests a potential role for this epitope in chronic inflammation. This study was able to develop an SRM approach to specifically identify and relatively quantitate sulfated core 1 isomers and the unsulfated structure. The expansion of this method may afford an avenue for the high throughput investigation of O-glycans.
Collapse
Affiliation(s)
- Sarah A Flowers
- Department of Medical Biochemistry, Institute of Biomedicine, University of Gothenburg, Medicinaregatan 9A, 405 30, Gothenburg, Sweden
| | | | | | | | | |
Collapse
|
28
|
Zhang F, Yu C, Wang W, Fan R, Zhang Z, Guo Y. Rapid simultaneous screening and identification of multiple pesticide residues in vegetables. Anal Chim Acta 2012. [DOI: 10.1016/j.aca.2012.10.048] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|